Selemani MA, Martin RS. Use of 3D printing to integrate microchip electrophoresis with amperometric detection. Anal Bioanal Chem 2024; 416:4749-4758. [PMID: 38581532 DOI: 10.1007/s00216-024-05260-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 03/08/2024] [Accepted: 03/15/2024] [Indexed: 04/08/2024]
Abstract
This paper describes the use of PolyJet 3D printing to fabricate microchip electrophoresis devices with integrated microwire electrodes for amperometric detection. The fabrication process involves 3D printing of two separate pieces, a channel layer and an electrode layer. The channel layer is created by 3D printing on a pre-fabricated mold with a T-intersection. For the electrode layer, a stencil design is printed directly on the printing tray and covered with a piece of transparent glass. Microwire electrodes are adhered over the glass piece (guided by underlaying stencil) and a CAD design of the electrode layer is then printed on top of the microwire electrode. After delamination from the glass after printing, the microwire is embedded in the printed piece, with the stencil design ensuring that alignment and positioning of the electrode is reproducible for each print. After a thermal bonding step between the channel layer and electrode layer, a complete electrophoresis device with integrated microelectrodes for amperometric detection results. It is shown that this approach enables different microwire electrodes (gold or platinum) and sizes (100 or 50 µm) to be integrated in an end-channel configuration with no gap between the electrode and the separation channel. These devices were used to separate a mixture of catecholamines and the effect of separation voltage on the potential voltage applied on the working electrode was also investigated. In addition, the effect of electrode size on the number of theoretical plates and limit of detection was studied. Finally, a device that contains different channel heights and a detection electrode was 3D-printed to integrate continuous flow sampling with microchip electrophoresis and amperometric detection.
Collapse
Affiliation(s)
- Major A Selemani
- Department of Chemistry, Saint Louis University, Saint Louis, MO, USA
| | - R Scott Martin
- Department of Chemistry, Saint Louis University, Saint Louis, MO, USA.
- Center for Additive Manufacturing, Saint Louis University, Saint Louis, MO, USA.
| |
Collapse
|
2
|
Ge S, Li G, Zhou X, Mao Y, Gu Y, Li Z, Gu Y, Cao X. Pump-free microfluidic chip based laryngeal squamous cell carcinoma-related microRNAs detection through the combination of surface-enhanced Raman scattering techniques and catalytic hairpin assembly amplification. Talanta 2022; 245:123478. [DOI: 10.1016/j.talanta.2022.123478] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 04/07/2022] [Accepted: 04/10/2022] [Indexed: 01/14/2023]
|
3
|
Bossink EGBM, Vollertsen AR, Loessberg-Zahl JT, van der Meer AD, Segerink LI, Odijk M. Systematic characterization of cleanroom-free fabricated macrovalves, demonstrating pumps and mixers for automated fluid handling tuned for organ-on-chip applications. MICROSYSTEMS & NANOENGINEERING 2022; 8:54. [PMID: 35615464 PMCID: PMC9124669 DOI: 10.1038/s41378-022-00378-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Accepted: 03/18/2022] [Indexed: 06/15/2023]
Abstract
Integrated valves enable automated control in microfluidic systems, as they can be applied for mixing, pumping and compartmentalization purposes. Such automation would be highly valuable for applications in organ-on-chip (OoC) systems. However, OoC systems typically have channel dimensions in the range of hundreds of micrometers, which is an order of magnitude larger than those of typical microfluidic valves. The most-used fabrication process for integrated, normally open polydimethylsiloxane (PDMS) valves requires a reflow photoresist that limits the achievable channel height. In addition, the low stroke volumes of these valves make it challenging to achieve flow rates of microliters per minute, which are typically required in OoC systems. Herein, we present a mechanical 'macrovalve' fabricated by multilayer soft lithography using micromilled direct molds. We demonstrate that these valves can close off rounded channels of up to 700 µm high and 1000 µm wide. Furthermore, we used these macrovalves to create a peristaltic pump with a pumping rate of up to 48 µL/min and a mixing and metering device that can achieve the complete mixing of a volume of 6.4 µL within only 17 s. An initial cell culture experiment demonstrated that a device with integrated macrovalves is biocompatible and allows the cell culture of endothelial cells over multiple days under continuous perfusion and automated medium refreshment.
Collapse
Affiliation(s)
- Elsbeth G. B. M. Bossink
- BIOS Lab on a Chip Group, MESA+Institute, Technical Medical Center, Max Planck Institute for Complex Fluid Dynamics, University of Twente, Enschede, The Netherlands
| | - Anke R. Vollertsen
- BIOS Lab on a Chip Group, MESA+Institute, Technical Medical Center, Max Planck Institute for Complex Fluid Dynamics, University of Twente, Enschede, The Netherlands
- Applied Stem Cell Technologies Group, Technical Medical Center, University of Twente, Enschede, The Netherlands
| | - Joshua T. Loessberg-Zahl
- BIOS Lab on a Chip Group, MESA+Institute, Technical Medical Center, Max Planck Institute for Complex Fluid Dynamics, University of Twente, Enschede, The Netherlands
| | - Andries D. van der Meer
- Applied Stem Cell Technologies Group, Technical Medical Center, University of Twente, Enschede, The Netherlands
| | - Loes I. Segerink
- BIOS Lab on a Chip Group, MESA+Institute, Technical Medical Center, Max Planck Institute for Complex Fluid Dynamics, University of Twente, Enschede, The Netherlands
| | - Mathieu Odijk
- BIOS Lab on a Chip Group, MESA+Institute, Technical Medical Center, Max Planck Institute for Complex Fluid Dynamics, University of Twente, Enschede, The Netherlands
| |
Collapse
|
4
|
Selemani M, Castiaux AD, Martin RS. PolyJet-Based 3D Printing against Micromolds to Produce Channel Structures for Microchip Electrophoresis. ACS OMEGA 2022; 7:13362-13370. [PMID: 35474767 PMCID: PMC9026087 DOI: 10.1021/acsomega.2c01265] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Accepted: 03/17/2022] [Indexed: 06/14/2023]
Abstract
In this work, we demonstrate the ability to use micromolds along with a stacked three-dimensional (3D) printing process on a commercially available PolyJet printer to fabricate microchip electrophoresis devices that have a T-intersection, with channel cross sections as small as 48 × 12 μm2 being possible. The fabrication process involves embedding removable materials or molds during the printing process, with various molds being possible (wires, brass molds, PDMS molds, or sacrificial materials). When the molds are delaminated/removed, recessed features complementary to the molds are left in the 3D prints. A thermal lab press is used to bond the microchannel layer that also contains printed reservoirs against another solid 3D-printed part to completely seal the microchannels. The devices exhibited cathodic electroosmotic flow (EOF), and mixtures of fluorescein isothiocyanate isomer I (FITC)-labeled amino acids were successfully separated on these 3D-printed devices using both gated and pinched electrokinetic injections. While this application is focused on microchip electrophoresis, the ability to 3D-print against molds that can subsequently be removed is a general methodology to decrease the channel size for other applications as well as to possibly integrate 3D printing with other production processes.
Collapse
Affiliation(s)
- Major
A. Selemani
- Department
of Chemistry, Saint Louis University, 3501 Laclede Ave., St. Louis, Missouri 63103, United States
| | - Andre D. Castiaux
- Center
for Additive Manufacturing, Saint Louis
University, 240 N Grand
Blvd, Saint Louis, Missouri 63103, United States
| | - R. Scott Martin
- Department
of Chemistry, Saint Louis University, 3501 Laclede Ave., St. Louis, Missouri 63103, United States
- Center
for Additive Manufacturing, Saint Louis
University, 240 N Grand
Blvd, Saint Louis, Missouri 63103, United States
| |
Collapse
|
5
|
Castiaux AD, Selemani MA, Ward MA, Martin RS. Fully 3D printed fluidic devices with integrated valves and pumps for flow injection analysis. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:5017-5024. [PMID: 34643627 PMCID: PMC8638614 DOI: 10.1039/d1ay01569a] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The use of a PolyJet 3D printer to create a microfluidic device that has integrated valves and pumps is described. The process uses liquid support and stacked printing to result in fully printed devices that are ready to use within minutes of fabrication after minimal post-processing. A unique feature of PolyJet printing is the ability to incorporate several different materials of varying properties into one print. In this work, two commercially available materials were used: a rigid-transparent plastic material (VeroClear) was used to define the channel regions and the bulk of the device, while the pumps/valves were printed in a flexible, rubber-like material (Agilus30). The entire process, from initial design to testing takes less than 4 hours to complete. The performance of the valves and pumps were characterized by fluorescence microscopy. A flow injection analysis device that enabled the discrete injections of analyte plugs was created, with on-chip pumps being used to move the fluid streams. The injection process was found to be reproducible and linearly correlated with changes in analyte concentration. The utility was demonstrated with the injection and rapid lysis of fluorescently-labeled endothelial cells. The ability to produce a device with integrated pumps/valves in one process significantly adds to the applicability of 3D printing to create microfluidic devices for analytical measurements.
Collapse
Affiliation(s)
- Andre D Castiaux
- Department of Chemistry, Saint Louis University, USA
- Department of Chemistry, Center for Additive Manufacturing, Saint Louis University, 3501 Laclede Ave., St. Louis, MO, 63103, USA.
| | | | - Morgan A Ward
- Department of Chemistry, Saint Louis University, USA
| | - R Scott Martin
- Department of Chemistry, Saint Louis University, USA
- Department of Chemistry, Center for Additive Manufacturing, Saint Louis University, 3501 Laclede Ave., St. Louis, MO, 63103, USA.
| |
Collapse
|
6
|
Malik M, Yang Y, Fathi P, Mahler GJ, Esch MB. Critical Considerations for the Design of Multi-Organ Microphysiological Systems (MPS). Front Cell Dev Biol 2021; 9:721338. [PMID: 34568333 PMCID: PMC8459628 DOI: 10.3389/fcell.2021.721338] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Accepted: 08/05/2021] [Indexed: 12/19/2022] Open
Abstract
Identification and approval of new drugs for use in patients requires extensive preclinical studies and clinical trials. Preclinical studies rely on in vitro experiments and animal models of human diseases. The transferability of drug toxicity and efficacy estimates to humans from animal models is being called into question. Subsequent clinical studies often reveal lower than expected efficacy and higher drug toxicity in humans than that seen in animal models. Microphysiological systems (MPS), sometimes called organ or human-on-chip models, present a potential alternative to animal-based models used for drug toxicity screening. This review discusses multi-organ MPS that can be used to model diseases and test the efficacy and safety of drug candidates. The translation of an in vivo environment to an in vitro system requires physiologically relevant organ scaling, vascular dimensions, and appropriate flow rates. Even small changes in those parameters can alter the outcome of experiments conducted with MPS. With many MPS devices being developed, we have outlined some established standards for designing MPS devices and described techniques to validate the devices. A physiologically realistic mimic of the human body can help determine the dose response and toxicity effects of a new drug candidate with higher predictive power.
Collapse
Affiliation(s)
- Mridu Malik
- Department of Bioengineering, University of Maryland, College Park, College Park, MD, United States
- Biophysical and Biomedical Measurement Group, Physical Measurement Laboratory, Microsystems and Nanotechnology Division, National Institute of Standards and Technology, Gaithersburg, MD, United States
| | - Yang Yang
- Biophysical and Biomedical Measurement Group, Physical Measurement Laboratory, Microsystems and Nanotechnology Division, National Institute of Standards and Technology, Gaithersburg, MD, United States
- Department of Chemical Engineering, University of Maryland, College Park, College Park, MD, United States
| | - Parinaz Fathi
- Department of Bioengineering, Materials Science and Engineering, and Beckman Institute, University of Illinois at Urbana-Champaign, Champaign, IL, United States
| | - Gretchen J. Mahler
- Department of Biomedical Engineering, Binghamton University, Binghamton, NY, United States
| | - Mandy B. Esch
- Biophysical and Biomedical Measurement Group, Physical Measurement Laboratory, Microsystems and Nanotechnology Division, National Institute of Standards and Technology, Gaithersburg, MD, United States
| |
Collapse
|
7
|
Microchip electrophoresis and electrochemical detection: A review on a growing synergistic implementation. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.138928] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
8
|
Liu Y, Xia L, Dutta D. Reduction in sample injection bias using pressure gradients generated on chip. Electrophoresis 2021; 42:983-990. [PMID: 33569844 DOI: 10.1002/elps.202000299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 01/21/2021] [Accepted: 01/29/2021] [Indexed: 11/10/2022]
Abstract
Sample injection in microchip-based capillary zone electrophoresis (CZE) frequently rely on the use of electric fields which can introduce differences in the injected volume for the various analytes depending on their electrophoretic mobilities and molecular diffusivities. While such injection biases may be minimized by employing hydrodynamic flows during the injection process, this approach typically requires excellent dynamic control over the pressure gradients applied within a microfluidic network. The current article describes a microchip device that offers this needed control by generating pressure gradients on-chip via electrokinetic means to minimize the dead volume in the system. In order to realize the desired pressure-generation capability, an electric field was applied across two channel segments of different depths to produce a mismatch in the electroosmotic flow rate at their junction. The resulting pressure-driven flow was then utilized to introduce sample zones into a CZE channel with minimal injection bias. The reported injection strategy allowed the introduction of narrow sample plugs with spatial standard deviations down to about 45 μm. This injection technique was later integrated to a capillary zone electrophoresis process for analyzing amino acid samples yielding separation resolutions of about 4-6 for the analyte peaks in a 3 cm long analysis channel.
Collapse
Affiliation(s)
- Yukari Liu
- Department of Chemistry, University of Wyoming, Laramie, WY, 82071, USA
| | - Ling Xia
- Department of Chemistry, University of Wyoming, Laramie, WY, 82071, USA
| | - Debashis Dutta
- Department of Chemistry, University of Wyoming, Laramie, WY, 82071, USA
| |
Collapse
|
9
|
Jones J, Ha NS, Barajas AG, Chatziioannou AF, van Dam RM. Integration of High-Resolution Radiation Detector for Hybrid Microchip Electrophoresis. Anal Chem 2020; 92:3483-3491. [PMID: 31986878 PMCID: PMC7410349 DOI: 10.1021/acs.analchem.9b04827] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
For decades, there has been immense progress in miniaturizing analytical methods based on electrophoresis to improve sensitivity and to reduce sample volumes, separation times, and/or equipment cost and space requirements, in applications ranging from analysis of biological samples to environmental analysis to forensics. In the field of radiochemistry, where radiation-shielded laboratory space is limited, there has been great interest in harnessing the compactness, high efficiency, and speed of microfluidics to synthesize short-lived radiolabeled compounds. We recently proposed that analysis of these compounds could also benefit from miniaturization and have been investigating capillary electrophoresis (CE) and hybrid microchip electrophoresis (hybrid-MCE) as alternatives to the typically used high-performance liquid chromatography (HPLC). We previously showed separation of the positron-emission tomography (PET) imaging tracer 3'-deoxy-3'-fluorothymidine (FLT) from its impurities in a hybrid-MCE device with UV detection, with similar separation performance to HPLC, but with improved speed and lower sample volumes. In this paper, we have developed an integrated radiation detector to enable measurement of the emitted radiation from radiolabeled compounds. Though conventional radiation detectors have been incorporated into CE systems in the past, these approaches cannot be readily integrated into a compact hybrid-MCE device. We instead employed a solid-state avalanche photodiode (APD)-based detector for real-time, high-sensitivity β particle detection. The integrated system can reliably separate [18F]FLT from its impurities and perform chemical identification via coinjection with nonradioactive reference standard. This system can quantitate samples with radioactivity concentrations as low as 114 MBq/mL (3.1 mCi/mL), which is sufficient for analysis of radiochemical purity of radiopharmaceuticals.
Collapse
Affiliation(s)
- Jason Jones
- Crump Institute for Molecular Imaging and Department of
Molecular and Medical Pharmacology, David Geffen School of Medicine, University of
California Los Angeles, Los Angeles, CA 90095, USA
- Physics & Biology in Medicine Interdepartmental
Graduate Program, David Geffen School of Medicine, University of California Los
Angeles, Los Angeles, CA 90095, USA
| | - Noel S. Ha
- Crump Institute for Molecular Imaging and Department of
Molecular and Medical Pharmacology, David Geffen School of Medicine, University of
California Los Angeles, Los Angeles, CA 90095, USA
- Department of Bioengineering, Henry Samueli School of
Engineering and Applied Science, University of California Los Angeles, Los Angeles,
CA 90095, USA
| | - Alec G. Barajas
- Crump Institute for Molecular Imaging and Department of
Molecular and Medical Pharmacology, David Geffen School of Medicine, University of
California Los Angeles, Los Angeles, CA 90095, USA
- Department of Chemistry & Biochemistry, University of
California Los Angeles, Los Angeles, CA 90095, USA
| | - Arion F. Chatziioannou
- Crump Institute for Molecular Imaging and Department of
Molecular and Medical Pharmacology, David Geffen School of Medicine, University of
California Los Angeles, Los Angeles, CA 90095, USA
- Physics & Biology in Medicine Interdepartmental
Graduate Program, David Geffen School of Medicine, University of California Los
Angeles, Los Angeles, CA 90095, USA
- Department of Molecular & Medical Pharmacology,
University of California Los Angeles, Los Angeles, CA 90095, USA
| | - R. Michael van Dam
- Crump Institute for Molecular Imaging and Department of
Molecular and Medical Pharmacology, David Geffen School of Medicine, University of
California Los Angeles, Los Angeles, CA 90095, USA
- Physics & Biology in Medicine Interdepartmental
Graduate Program, David Geffen School of Medicine, University of California Los
Angeles, Los Angeles, CA 90095, USA
- Department of Bioengineering, Henry Samueli School of
Engineering and Applied Science, University of California Los Angeles, Los Angeles,
CA 90095, USA
- Department of Molecular & Medical Pharmacology,
University of California Los Angeles, Los Angeles, CA 90095, USA
| |
Collapse
|
10
|
Morioka K, Sato H, Morita K, Akihide H, Nakajima H, Shoji A, Yanagida A. Development of an on-chip sample injection system with a 6-port valve incorporated in a microchip. RSC Adv 2020; 10:35848-35855. [PMID: 35517096 PMCID: PMC9056900 DOI: 10.1039/d0ra07043b] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2020] [Accepted: 09/18/2020] [Indexed: 11/30/2022] Open
Abstract
Micro-flow-injection analysis (μFIA) is amenable to high-throughput systems with lower consumption of sample and reagent volumes. On-chip sample injection methods are important to prevent reduced analytical performance associated with dead volumes and diffusion of sample solutions. In this study, we have developed an on-chip sample injection system with a small-sized 6-port valve incorporated on a microchip. The valve is made with a 3D printer and is a simple structure that can be easily operated manually. A sample solution in a loading channel can be injected by switching the valve from the load to injection position. Sample injection tests using resorufin solutions revealed that samples can be injected below 100 μL min−1, and the performance of the sample injection system is comparable to that of a commercially available injector. In addition, the sample injection system was successfully applied to a flow-based assay for hydrogen peroxide. The detection limit (3σ) of hydrogen peroxide was estimated to be 0.5 μM, and the assay time after sample injection was approximately 100 s. The developed sample injection system will be useful for various microfluidic-based analyses including μFIA. We demonstrate on-chip sample injection using a 6-port valve incorporated in a microchip.![]()
Collapse
Affiliation(s)
- Kazuhiro Morioka
- Department of Biomedical Analysis
- School of Pharmacy
- Tokyo University of Pharmacy and Life Sciences
- Hachioji
- Japan
| | - Hina Sato
- Department of Biomedical Analysis
- School of Pharmacy
- Tokyo University of Pharmacy and Life Sciences
- Hachioji
- Japan
| | - Kenji Morita
- Department of Biomedical Analysis
- School of Pharmacy
- Tokyo University of Pharmacy and Life Sciences
- Hachioji
- Japan
| | | | - Hizuru Nakajima
- Department of Applied Chemistry
- Graduate School of Urban Environmental Science
- Tokyo Metropolitan University
- Hachioji
- Japan
| | - Atsushi Shoji
- Department of Biomedical Analysis
- School of Pharmacy
- Tokyo University of Pharmacy and Life Sciences
- Hachioji
- Japan
| | - Akio Yanagida
- Department of Biomedical Analysis
- School of Pharmacy
- Tokyo University of Pharmacy and Life Sciences
- Hachioji
- Japan
| |
Collapse
|
11
|
Soucy JR, Bindas AJ, Koppes AN, Koppes RA. Instrumented Microphysiological Systems for Real-Time Measurement and Manipulation of Cellular Electrochemical Processes. iScience 2019; 21:521-548. [PMID: 31715497 PMCID: PMC6849363 DOI: 10.1016/j.isci.2019.10.052] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2019] [Revised: 10/17/2019] [Accepted: 10/24/2019] [Indexed: 12/17/2022] Open
Abstract
Recent advancements in electronic materials and subsequent surface modifications have facilitated real-time measurements of cellular processes far beyond traditional passive recordings of neurons and muscle cells. Specifically, the functionalization of conductive materials with ligand-binding aptamers has permitted the utilization of traditional electronic materials for bioelectronic sensing. Further, microfabrication techniques have better allowed microfluidic devices to recapitulate the physiological and pathological conditions of complex tissues and organs in vitro or microphysiological systems (MPS). The convergence of these models with advances in biological/biomedical microelectromechanical systems (BioMEMS) instrumentation has rapidly bolstered a wide array of bioelectronic platforms for real-time cellular analytics. In this review, we provide an overview of the sensing techniques that are relevant to MPS development and highlight the different organ systems to integrate instrumentation for measurement and manipulation of cellular function. Special attention is given to how instrumented MPS can disrupt the drug development and fundamental mechanistic discovery processes.
Collapse
Affiliation(s)
- Jonathan R Soucy
- Department of Chemical Engineering, Northeastern University, Boston, MA 02115, USA
| | - Adam J Bindas
- Department of Chemical Engineering, Northeastern University, Boston, MA 02115, USA
| | - Abigail N Koppes
- Department of Chemical Engineering, Northeastern University, Boston, MA 02115, USA; Department of Biology, Northeastern University, Boston, MA 02115, USA
| | - Ryan A Koppes
- Department of Chemical Engineering, Northeastern University, Boston, MA 02115, USA.
| |
Collapse
|
12
|
Townsend AD, Sprague RS, Martin RS. Microfluidic device using a gold pillar array and integrated electrodes for on-chip endothelial cell immobilization, direct RBC contact, and amperometric detection of nitric oxide. ELECTROANAL 2019; 31:1409-1415. [PMID: 32999581 DOI: 10.1002/elan.201900157] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
We describe a microfluidic device that can be used to detect interactions between red blood cells (RBCs) and endothelial cells using a gold pillar array (created by electrodeposition) and an integrated detection electrode. Endothelial cells can release nitric oxide (NO) via stimulation by RBC-derived ATP. These studies incorporate on-chip endothelial cell immobilization, direct RBC contact, and detection of NO in a single microfluidic device. In order to study the RBC-EC interactions, this work used a microfluidic device made of a PDMS chip with two adjacent channels and a polystyrene base with embedded electrodes for creating a membrane (via gold pillars) and detecting NO (at a glassy carbon electrode coated with platinum-black and Nafion). RBCs were pharmacologically treated with treprostinil in the absence and presence of glybenclamide, and ATP release was determined as was the resultant NO release from endothelial cells. Treprostinil treatment of RBCs resulted in ATP release that stimulated endothelial cells to release on average 1.8 ± 0.2 nM NO per endothelial cell (average ± SEM, n = 8). Pretreatment of RBCs with glybenclamide inhibited treprostinil-induced ATP release and, therefore, less NO was produced by the endothelial cells (0.92 ± 0.1 nM NO per endothelial cell, n = 7). In the future, this device can be used to study interactions between many other cell types (both adherent and non-adherent cell lines) and incorporate other detection schemes.
Collapse
Affiliation(s)
- Alexandra D Townsend
- Department of Chemistry, Saint Louis University, 3501 Laclede Avenue, Saint Louis, MO 63103
| | - Randy S Sprague
- Department of Pharmacological and Physiological Science, Saint Louis University, 1402 S. Grand Boulevard, Saint Louis, MO 63103
| | - R Scott Martin
- Department of Chemistry, Saint Louis University, 3501 Laclede Avenue, Saint Louis, MO 63103
| |
Collapse
|
13
|
Mehl BT, Martin RS. Integrating 3D Cell Culture of PC12 Cells with Microchip-Based Electrochemical Detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2019; 11:1064-1072. [PMID: 31244918 PMCID: PMC6594695 DOI: 10.1039/c8ay02672f] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Developing in vitro cell culture models that accurately mimic in vivo processes in a manner that also enables near real-time analysis of neurotransmitters is an important research area. New technologies being developed such as 3D scaffolds for cell culture and 3D printed microfluidics provide an opportunity for such advancements. In this work, PC12 cells were used as a model system and they were immobilized onto a 3D scaffold of polystyrene (PS) fibers. These fibers were created by electrospinning onto PS sheets, which were laser cut and, after cell seeding, inserted into a 3D printed microfluidic device. The 3D printed device was designed with threads for connecting commercial fittings (to integrate automated pumps and a 4-port injection system) and a steel pin for simple coupling with PDMS/polystyrene analytical devices. A straight PDMS channel was used for simple (and continuous) flow-based detection by sealing onto a PS base containing an embedded gold array working electrode and a platinum pseudo-reference. Electrochemical detection of stimulated catecholamine release was demonstrated. The insert-based system was then integrated with a bilayer valving PDMS device (for microchip electrophoresis) sealed onto a PS base (with electrodes for electrochemical detection). This base was embedded with a Pd decoupler (for grounding the separation voltage and adsorbing hydrogen) and a 33 µm carbon fiber working electrode for in-channel detection. PC12 cells were stimulated in the 3D cell culture device, and the valving/electrophoresis microchip was able to separate and detect dopamine and norepinephrine release. This work demonstrates the ability to integrate 3D cell scaffolds with microchip-based analysis for detection of multiple analytes released from cells.
Collapse
|
14
|
Munshi AS, Chen C, Townsend AD, Martin RS. Use of 3D Printing and Modular Microfluidics to Integrate Cell Culture, Injections and Electrochemical Analysis. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2018; 10:3364-3374. [PMID: 30923580 PMCID: PMC6433419 DOI: 10.1039/c8ay00829a] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Fabrication of microchip-based devices using 3-D printing technology offers a unique platform to create separate modules that can be put together when desired for analysis. A 3-D printed module approach offers various advantages such as file sharing and the ability to easily replace, customize, and modify the individual modules. Here, we describe the use of a modular approach to electrochemically detect the ATP-mediated release of nitric oxide (NO) from endothelial cells. Nitric oxide plays a significant role in the vasodilation process; however, detection of NO is challenging due to its short half-life. To enable this analysis, we use three distinct 3-D printed modules: cell culture, sample injection and detection modules. The detection module follows a pillar-based Wall-Jet Electrode design, where the analyte impinges normal to the electrode surface, offering enhanced sensitivity for the analyte. To further enhance the sensitivity and selectivity for NO detection the working electrode (100 μm gold) is modified by the addition of a 27 μm gold pillar and platinum-black coated with Nafion. The use of the pillar electrode leads to three-dimensional structure protruding into the channel enhancing the sensitivity by 12.4 times in comparison to the flat electrode (resulting LOD for NO = 210 nM). The next module, the 3-D printed sample injection module, follows a simple 4-Port injection rotor design made of two separate components that when assembled can introduce a specific volume of analyte. This module not only serves as a cheaper alternative to the commercially available 4-Port injection valves, but also demonstrates the ability of volume customization and reduced dead-volume issues with the use of capillary-free connections. Comparison between the 3-D printed and a commercial 4-Port injection valve showed similar sensitivities and reproducibility for NO analysis. Lastly, the cell culture module contains electrospun polystyrene fibers with immobilized endothelial cells, resulting in 3-D scaffold for cell culture. With the incorporation of all 3 modules, we can make reproducible ATP injections (via the 3-D printed sample injection module) that can stimulate NO release from endothelial cells cultured on a fibrous insert in the cell culture module which can then be quantitated by the pillar WJE module (0.19 ± 0.03 nM/cell, n = 27, 3 inserts analyzed each day, on 9 different days). The modular approach demonstrates the facile creation of custom and modifiable fluidic components that can be assembled as needed.
Collapse
Affiliation(s)
| | | | | | - R. Scott Martin
- corresponding author: Dr. R. Scott Martin, 3501 Laclede Ave, St. Louis, MO, USA 63103, +1 314-977-2836,
| |
Collapse
|
15
|
Mehl BT, Martin RS. Enhanced Microchip Electrophoresis Separations Combined with Electrochemical Detection Utilizing a Capillary Embedded in Polystyrene. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2018; 10:37-45. [PMID: 29707044 PMCID: PMC5915312 DOI: 10.1039/c7ay02505j] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
The ability to use microchip-based electrophoresis for fast, high-throughput separations provides researchers with a tool for close-to real time analysis of biological systems. While PDMS-based electrophoresis devices are popular, the separation efficiency is often an issue due to the hydrophobic nature of PDMS. In this study, a hybrid microfluidic capillary device was fabricated to utilize the positive features of PDMS along with the electrophoretic performance of fused silica. A capillary loop was embedded in a polystyrene base that can be coupled with PDMS microchannels at minimal dead volume interconnects. A method for cleaning out the capillaries after a wet-polishing step was devised through the use of 3D printed syringe attachment. By comparing the separation efficiency of fluorescein and CBI-glycine with both a PDMS-based serpentine device and the embedded capillary loop device, it was shown that the embedded capillary loop device maintained higher theoretical plates for both analytes. A Pd decoupler with a carbon or Pt detection electrode were embedded along with the loop allowing integration of the electrophoretic separation with electrochemical detection. A series of catecholamines were separated to show the ability to resolve similar analytes and detect redox active species. The release of dopamine and norepinephrine from PC 12 cells was also analyzed showing the compatibility of these improved microchip separations with high ionic cell buffers associated with cell culture.
Collapse
|
16
|
Sahore V, Sonker M, Nielsen AV, Knob R, Kumar S, Woolley AT. Automated microfluidic devices integrating solid-phase extraction, fluorescent labeling, and microchip electrophoresis for preterm birth biomarker analysis. Anal Bioanal Chem 2018; 410:933-941. [PMID: 28799040 PMCID: PMC5775915 DOI: 10.1007/s00216-017-0548-7] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2017] [Revised: 07/18/2017] [Accepted: 07/25/2017] [Indexed: 01/19/2023]
Abstract
We have developed multichannel integrated microfluidic devices for automated preconcentration, labeling, purification, and separation of preterm birth (PTB) biomarkers. We fabricated multilayer poly(dimethylsiloxane)-cyclic olefin copolymer (PDMS-COC) devices that perform solid-phase extraction (SPE) and microchip electrophoresis (μCE) for automated PTB biomarker analysis. The PDMS control layer had a peristaltic pump and pneumatic valves for flow control, while the PDMS fluidic layer had five input reservoirs connected to microchannels and a μCE system. The COC layers had a reversed-phase octyl methacrylate porous polymer monolith for SPE and fluorescent labeling of PTB biomarkers. We determined μCE conditions for two PTB biomarkers, ferritin (Fer) and corticotropin-releasing factor (CRF). We used these integrated microfluidic devices to preconcentrate and purify off-chip-labeled Fer and CRF in an automated fashion. Finally, we performed a fully automated on-chip analysis of unlabeled PTB biomarkers, involving SPE, labeling, and μCE separation with 1 h total analysis time. These integrated systems have strong potential to be combined with upstream immunoaffinity extraction, offering a compact sample-to-answer biomarker analysis platform. Graphical abstract Pressure-actuated integrated microfluidic devices have been developed for automated solid-phase extraction, fluorescent labeling, and microchip electrophoresis of preterm birth biomarkers.
Collapse
Affiliation(s)
- Vishal Sahore
- Department of Chemistry and Biochemistry, Brigham Young University, C100 BNSN, Provo, UT, 84602-5700, USA
| | - Mukul Sonker
- Department of Chemistry and Biochemistry, Brigham Young University, C100 BNSN, Provo, UT, 84602-5700, USA
| | - Anna V Nielsen
- Department of Chemistry and Biochemistry, Brigham Young University, C100 BNSN, Provo, UT, 84602-5700, USA
| | - Radim Knob
- Department of Chemistry and Biochemistry, Brigham Young University, C100 BNSN, Provo, UT, 84602-5700, USA
| | - Suresh Kumar
- Department of Chemistry and Biochemistry, Brigham Young University, C100 BNSN, Provo, UT, 84602-5700, USA
| | - Adam T Woolley
- Department of Chemistry and Biochemistry, Brigham Young University, C100 BNSN, Provo, UT, 84602-5700, USA.
| |
Collapse
|
17
|
Ha NS, Sadeghi S, van Dam RM. Recent Progress toward Microfluidic Quality Control Testing of Radiopharmaceuticals. MICROMACHINES 2017; 8:E337. [PMID: 30400527 PMCID: PMC6190332 DOI: 10.3390/mi8110337] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/27/2017] [Revised: 11/08/2017] [Accepted: 11/18/2017] [Indexed: 01/18/2023]
Abstract
Radiopharmaceuticals labeled with short-lived positron-emitting or gamma-emitting isotopes are injected into patients just prior to performing positron emission tomography (PET) or single photon emission tomography (SPECT) scans, respectively. These imaging modalities are widely used in clinical care, as well as in the development and evaluation of new therapies in clinical research. Prior to injection, these radiopharmaceuticals (tracers) must undergo quality control (QC) testing to ensure product purity, identity, and safety for human use. Quality tests can be broadly categorized as (i) pharmaceutical tests, needed to ensure molecular identity, physiological compatibility and that no microbiological, pyrogenic, chemical, or particulate contamination is present in the final preparation; and (ii) radioactive tests, needed to ensure proper dosing and that there are no radiochemical and radionuclidic impurities that could interfere with the biodistribution or imaging. Performing the required QC tests is cumbersome and time-consuming, and requires an array of expensive analytical chemistry equipment and significant dedicated lab space. Calibrations, day of use tests, and documentation create an additional burden. Furthermore, in contrast to ordinary pharmaceuticals, each batch of short-lived radiopharmaceuticals must be manufactured and tested within a short period of time to avoid significant losses due to radioactive decay. To meet these challenges, several efforts are underway to develop integrated QC testing instruments that automatically perform and document all of the required tests. More recently, microfluidic quality control systems have been gaining increasing attention due to vastly reduced sample and reagent consumption, shorter analysis times, higher detection sensitivity, increased multiplexing, and reduced instrumentation size. In this review, we describe each of the required QC tests and conventional testing methods, followed by a discussion of efforts to directly miniaturize the test or examples in the literature that could be implemented for miniaturized QC testing.
Collapse
Affiliation(s)
- Noel S Ha
- Department of Bioengineering, Henry Samueli School of Engineering and Applied Science, University of California Los Angeles, Los Angeles, CA 90095, USA.
- Crump Institute for Molecular Imaging and Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90095, USA.
| | - Saman Sadeghi
- Crump Institute for Molecular Imaging and Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90095, USA.
| | - R Michael van Dam
- Department of Bioengineering, Henry Samueli School of Engineering and Applied Science, University of California Los Angeles, Los Angeles, CA 90095, USA.
- Crump Institute for Molecular Imaging and Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90095, USA.
| |
Collapse
|
18
|
Affiliation(s)
- Xilong Yuan
- Department of Chemistry, Queen's University , Kingston, Ontario K7L 3N6, Canada
| | - Richard D Oleschuk
- Department of Chemistry, Queen's University , Kingston, Ontario K7L 3N6, Canada
| |
Collapse
|
19
|
Novel volumetric method for highly repeatable injection in microchip electrophoresis. Anal Chim Acta 2017; 985:129-140. [PMID: 28864183 DOI: 10.1016/j.aca.2017.05.037] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2017] [Revised: 05/22/2017] [Accepted: 05/22/2017] [Indexed: 12/25/2022]
Abstract
A novel injector for microchip electrophoresis (MCE) has been designed and evaluated that achieves very high repeatability of injection volume suitable for quantitative analysis. It eliminates the injection biases in electrokinetic injection and the dependence on pressure and sample properties in hydrodynamic injection. The microfluidic injector, made of poly(dimethylsiloxane) (PDMS), operates similarly to an HPLC injection valve. It contains a channel segment (chamber) with a well-defined volume that serves as an "injection loop". Using on-chip microvalves, the chamber can be connected to the sample source during the "loading" step, and to the CE separation channel during the "injection" step. Once the valves are opened in the second state, electrophoretic potential is applied to separate the sample. For evaluation and demonstration purposes, the microinjector was connected to a 75 μm ID capillary and UV absorbance detector. For single compounds, a relative standard deviation (RSD) of peak area as low as 1.04% (n = 11) was obtained, and for compound mixtures, RSD as low as 0.40% (n = 4) was observed. Using the same microchip, the performance of this new injection technique was compared to hydrodynamic injection and found to have improved repeatability and less dependence on sample viscosity. Furthermore, a non-radioactive version of the positron-emission tomography (PET) imaging probe, FLT, was successfully separated from its known 3 structurally-similar byproducts with baseline resolution, demonstrating the potential for rapid, quantitative analysis of impurities to ensure the safety of batches of short-lived radiotracers. Both the separation efficiency and injection repeatability were found to be substantially higher when using the novel volumetric injection approach compared to electrokinetic injection (performed in the same chip). This novel microinjector provides a straightforward way to improve the performance of hydrodynamic injection and enables extremely repeatable sample volume injection in MCE. It could be used in any MCE application where volume repeatability is needed, including the quantitation of impurities in pharmaceutical or radiopharmaceutical samples.
Collapse
|
20
|
Gabriel EF, dos Santos RA, Lobo-Júnior EO, Rezende KC, Coltro WK. Hydrodynamic injection on electrophoresis microchips using an electronic micropipette. Talanta 2017; 162:19-23. [DOI: 10.1016/j.talanta.2016.09.046] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2016] [Revised: 09/16/2016] [Accepted: 09/17/2016] [Indexed: 01/06/2023]
|
21
|
Dugan CE, Grinias JP, Parlee SD, El-Azzouny M, Evans CR, Kennedy RT. Monitoring cell secretions on microfluidic chips using solid-phase extraction with mass spectrometry. Anal Bioanal Chem 2016; 409:169-178. [PMID: 27761614 DOI: 10.1007/s00216-016-9983-0] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2016] [Revised: 09/19/2016] [Accepted: 09/27/2016] [Indexed: 01/09/2023]
Abstract
Microfluidics is an enabling technology for both cell biology and chemical analysis. We combine these attributes with a microfluidic device for on-line solid-phase extraction (SPE) and mass spectrometry (MS) analysis of secreted metabolites from living cells in culture on the chip. The device was constructed with polydimethylsiloxane (PDMS) and contains a reversibly sealed chamber for perfusing cells. A multilayer design allowed a series of valves to control an on-chip 7.5 μL injection loop downstream of the cell chamber with operation similar to a six-port valve. The valve collects sample and then diverts it to a packed SPE bed that was connected in-line to treat samples prior to MS analysis. The valve allows samples to be collected and injected onto the SPE bed while preventing exposure of cells to added back pressure from the SPE bed and organic solvents needed to elute collected chemicals. Here, cultured murine 3T3-L1 adipocytes were loaded into the cell chamber and non-esterified fatty acids (NEFAs) that were secreted by the cells were monitored by SPE-MS at 30 min intervals. The limit of detection for a palmitoleic acid standard was 1.4 μM. Due to the multiplexed detection capabilities of MS, a variety of NEFAs were detected. Upon stimulation with isoproterenol and forskolin, secretion of select NEFAs was elevated an average of 1.5-fold compared to basal levels. Despite the 30-min delay between sample injections, this device is a step towards a miniaturized system that allows automated monitoring and identification of a variety of molecules in the extracellular environment.
Collapse
Affiliation(s)
- Colleen E Dugan
- Department of Chemistry, University of Michigan, Ann Arbor, MI, 48109, USA
| | - James P Grinias
- Department of Chemistry, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Sebastian D Parlee
- Department of Molecular & Integrative Physiology, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Mahmoud El-Azzouny
- Department of Internal Medicine, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Charles R Evans
- Department of Internal Medicine, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Robert T Kennedy
- Department of Chemistry, University of Michigan, Ann Arbor, MI, 48109, USA. .,Department of Pharmacology, University of Michigan, Ann Arbor, MI, 48109, USA.
| |
Collapse
|
22
|
Schrell AM, Mukhitov N, Yi L, Wang X, Roper MG. Microfluidic Devices for the Measurement of Cellular Secretion. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2016; 9:249-69. [PMID: 27306310 DOI: 10.1146/annurev-anchem-071114-040409] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
The release of chemical information from cells and tissues holds the key to understanding cellular behavior and dysfunction. The development of methodologies that can measure cellular secretion in a time-dependent fashion is therefore essential. Often these measurements are made difficult by the high-salt conditions of the cellular environment, the presence of numerous other secreted factors, and the small mass samples that are produced when frequent sampling is used to resolve secretory dynamics. In this review, the methods that we have developed for measuring hormone release from islets of Langerhans are dissected to illustrate the practical difficulties of studying cellular secretions. Other methods from the literature are presented that provide alternative approaches to particularly challenging areas of monitoring cellular secretion. The examples presented in this review serve as case studies and should be adaptable to other cell types and systems for unique applications.
Collapse
Affiliation(s)
- Adrian M Schrell
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, Florida 32306;
| | - Nikita Mukhitov
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, Florida 32306;
| | - Lian Yi
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, Florida 32306;
| | - Xue Wang
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, Florida 32306;
| | - Michael G Roper
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, Florida 32306;
| |
Collapse
|
23
|
Munshi AS, Martin RS. Microchip-based electrochemical detection using a 3-D printed wall-jet electrode device. Analyst 2016; 141:862-9. [PMID: 26649363 PMCID: PMC5011427 DOI: 10.1039/c5an01956g] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Three dimensional (3-D) printing technology has evolved dramatically in the last few years, offering the capability of printing objects with a variety of materials. Printing microfluidic devices using this technology offers various advantages such as ease and uniformity of fabrication, file sharing between laboratories, and increased device-to-device reproducibility. One unique aspect of this technology, when used with electrochemical detection, is the ability to produce a microfluidic device as one unit while also allowing the reuse of the device and electrode for multiple analyses. Here we present an alternate electrode configuration for microfluidic devices, a wall-jet electrode (WJE) approach, created by 3-D printing. Using microchip-based flow injection analysis, we compared the WJE design with the conventionally used thin-layer electrode (TLE) design. It was found that the optimized WJE system enhances analytical performance (as compared to the TLE design), with improvements in sensitivity and the limit of detection. Experiments were conducted using two working electrodes - 500 μm platinum and 1 mm glassy carbon. Using the 500 μm platinum electrode the calibration sensitivity was 16 times higher for the WJE device (as compared to the TLE design). In addition, use of the 1 mm glassy carbon electrode led to limit of detection of 500 nM for catechol, as compared to 6 μM for the TLE device. Finally, to demonstrate the versatility and applicability of the 3-D printed WJE approach, the device was used as an inexpensive electrochemical detector for HPLC. The number of theoretical plates was comparable to the use of commercially available UV and MS detectors, with the WJE device being inexpensive to utilize. These results show that 3-D-printing can be a powerful tool to fabricate reusable and integrated microfluidic detectors in configurations that are not easily achieved with more traditional lithographic methods.
Collapse
Affiliation(s)
- Akash S Munshi
- Department of Chemistry, Saint Louis University, 3501 Laclede Avenue, St. Louis, MO 63103, USA.
| | | |
Collapse
|
24
|
SASAKI N, SATO K. Analytical Applications of Microfluidic Vascular Models. BUNSEKI KAGAKU 2016. [DOI: 10.2116/bunsekikagaku.65.241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Naoki SASAKI
- Department of Applied Chemistry, Faculty of Science and Engineering, Toyo University
| | - Kae SATO
- Department of Chemical and Biological Sciences, Faculty of Science, Japan Women’s University
| |
Collapse
|
25
|
Sahore V, Kumar S, Rogers CI, Jensen JK, Sonker M, Woolley AT. Pressure-actuated microfluidic devices for electrophoretic separation of pre-term birth biomarkers. Anal Bioanal Chem 2015; 408:599-607. [PMID: 26537925 DOI: 10.1007/s00216-015-9141-0] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2015] [Revised: 10/07/2015] [Accepted: 10/21/2015] [Indexed: 12/13/2022]
Abstract
We have developed microfluidic devices with pressure-driven injection for electrophoretic analysis of amino acids, peptides, and proteins. The novelty of our approach lies in the use of an externally actuated on-chip peristaltic pump and closely spaced pneumatic valves that allow well-defined, small-volume sample plugs to be injected and separated by microchip electrophoresis. We fabricated three-layer poly(dimethylsiloxane) (PDMS) microfluidic devices. The fluidic layer had injection and separation channels, and the control layer had an externally actuated on-chip peristaltic pump and four pneumatic valves around the T-intersection to carry out sample injection. An unpatterned PDMS membrane layer was sandwiched between the fluidic and control layers as the actuated component in pumps and valves. Devices with the same peristaltic pump design but different valve spacings (100, 200, 300, and 400 μm) from the injection intersection were fabricated using soft lithographic techniques. Devices were characterized through fluorescent imaging of captured plugs of a fluorescein-labeled amino acid mixture and through microchip electrophoresis separations. A suitable combination of peak height, separation efficiency, and analysis time was obtained with a peristaltic pump actuation rate of 50 ms, an injection time of 30 s, and a 200-μm valve spacing. We demonstrated the injection of samples in different solutions and were able to achieve a 2.4-fold improvement in peak height and a 2.8-fold increase in separation efficiency though sample stacking. A comparison of pressure-driven injection and electrokinetic injection with the same injection time and separation voltage showed a 3.9-fold increase in peak height in pressure-based injection with comparable separation efficiency. Finally, the microchip systems were used to separate biomarkers implicated in pre-term birth. Although these devices have initially been demonstrated as a stand-alone microfluidic separation tool, they have strong potential to be integrated within more complex systems.
Collapse
Affiliation(s)
- V Sahore
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA.
| | - S Kumar
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA.
| | - C I Rogers
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA.
| | - J K Jensen
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA.
| | - M Sonker
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA.
| | - A T Woolley
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA.
| |
Collapse
|
26
|
Johnson AS, Mehl BT, Martin RS. Integrated hybrid polystyrene-polydimethylsiloxane device for monitoring cellular release with microchip electrophoresis and electrochemical detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2015; 7:884-893. [PMID: 25663849 PMCID: PMC4318258 DOI: 10.1039/c4ay02569e] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
In this work, a polystyrene (PS)-polydimethylsiloxane (PDMS) hybrid device was developed to enable the integration of cell culture with analysis by microchip electrophoresis and electrochemical detection. It is shown that this approach combines the fundamental advantages of PDMS devices (the ability to integrate pumps and valves) and PS devices (the ability to permanently embed fluidic tubing and electrodes). The embedded fused-silica capillary enables high temporal resolution measurements from off-chip cell culture dishes and the embedded electrodes provide close to real-time analysis of small molecule neurotransmitters. A novel surface treatment for improved (reversible) adhesion between PS and PDMS is described using a chlorotrimethylsilane stamping method. It is demonstrated that a Pd decoupler is efficient at handling the high current (and cathodic hydrogen production) resulting from use of high ionic strength buffers needed for cellular analysis; thus allowing an electrophoretic separation and in-channel detection. The separation of norepinephrine (NE) and dopamine (DA) in highly conductive biological buffers was optimized using a mixed surfactant system. This PS-PDMS hybrid device integrates multiple processes including continuous sampling from a cell culture dish, on-chip pump and valving technologies, microchip electrophoresis, and electrochemical detection to monitor neurotransmitter release from PC 12 cells.
Collapse
Affiliation(s)
- Alicia S Johnson
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - Benjamin T Mehl
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - R Scott Martin
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| |
Collapse
|
27
|
da Costa ET, Mora MF, Willis PA, do Lago CL, Jiao H, Garcia CD. Getting started with open-hardware: development and control of microfluidic devices. Electrophoresis 2014; 35:2370-7. [PMID: 24823494 PMCID: PMC4176689 DOI: 10.1002/elps.201400128] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2014] [Revised: 05/07/2014] [Accepted: 05/07/2014] [Indexed: 12/20/2022]
Abstract
Understanding basic concepts of electronics and computer programming allows researchers to get the most out of the equipment found in their laboratories. Although a number of platforms have been specifically designed for the general public and are supported by a vast array of on-line tutorials, this subject is not normally included in university chemistry curricula. Aiming to provide the basic concepts of hardware and software, this article is focused on the design and use of a simple module to control a series of PDMS-based valves. The module is based on a low-cost microprocessor (Teensy) and open-source software (Arduino). The microvalves were fabricated using thin sheets of PDMS and patterned using CO2 laser engraving, providing a simple and efficient way to fabricate devices without the traditional photolithographic process or facilities. Synchronization of valve control enabled the development of two simple devices to perform injection (1.6 ± 0.4 μL/stroke) and mixing of different solutions. Furthermore, a practical demonstration of the utility of this system for microscale chemical sample handling and analysis was achieved performing an on-chip acid-base titration, followed by conductivity detection with an open-source low-cost detection system. Overall, the system provided a very reproducible (98%) platform to perform fluid delivery at the microfluidic scale.
Collapse
Affiliation(s)
- Eric Tavares da Costa
- Department of Chemistry, The University of Texas at San Antonio
- Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo
| | - Maria F. Mora
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena CA, USA
| | - Peter A. Willis
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena CA, USA
| | - Claudimir L. do Lago
- Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo
| | - Hong Jiao
- HJ Science & Technology, 2929 Seventh Street, Suite 120, Berkeley, CA 94710 Berkeley, CA, USA
| | | |
Collapse
|
28
|
Sato K, Sasaki N, Svahn HA, Sato K. Microfluidics for nano-pathophysiology. Adv Drug Deliv Rev 2014; 74:115-21. [PMID: 24001983 DOI: 10.1016/j.addr.2013.08.009] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2013] [Revised: 08/02/2013] [Accepted: 08/22/2013] [Indexed: 01/30/2023]
Abstract
Nanotechnology-based drug delivery systems hold promise for innovative medical treatment of cancers. While drug materials are constantly under development, there are no practical cell-based models to assess whether these materials can reach the target tissue. Recently developed microfluidic systems have revolutionized cell-based experiments. In these systems, vascular endothelial cells and interstitium are set in microchannels that mimic microvessels. Drug permeability can be assayed in these blood vessel models under fluidic conditions that mimic blood flow. In this review, we describe device fabrication, disease model development, nanoparticle permeability assays, and the potential utility of these systems in the future.
Collapse
|
29
|
Erkal JL, Selimovic A, Gross BC, Lockwood SY, Walton EL, McNamara S, Martin RS, Spence DM. 3D printed microfluidic devices with integrated versatile and reusable electrodes. LAB ON A CHIP 2014; 14:2023-32. [PMID: 24763966 PMCID: PMC4436701 DOI: 10.1039/c4lc00171k] [Citation(s) in RCA: 170] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
We report two 3D printed devices that can be used for electrochemical detection. In both cases, the electrode is housed in commercially available, polymer-based fittings so that the various electrode materials (platinum, platinum black, carbon, gold, silver) can be easily added to a threaded receiving port printed on the device; this enables a module-like approach to the experimental design, where the electrodes are removable and can be easily repolished for reuse after exposure to biological samples. The first printed device represents a microfluidic platform with a 500 × 500 μm channel and a threaded receiving port to allow integration of either polyetheretherketone (PEEK) nut-encased glassy carbon or platinum black (Pt-black) electrodes for dopamine and nitric oxide (NO) detection, respectively. The embedded 1 mm glassy carbon electrode had a limit of detection (LOD) of 500 nM for dopamine and a linear response (R(2) = 0.99) for concentrations between 25-500 μM. When the glassy carbon electrode was coated with 0.05% Nafion, significant exclusion of nitrite was observed when compared to signal obtained from equimolar injections of dopamine. When using flow injection analysis with a Pt/Pt-black electrode and standards derived from NO gas, a linear correlation (R(2) = 0.99) over a wide range of concentrations (7.6-190 μM) was obtained, with the LOD for NO being 1 μM. The second application showcases a 3D printed fluidic device that allows collection of the biologically relevant analyte adenosine triphosphate (ATP) while simultaneously measuring the release stimulus (reduced oxygen concentration). The hypoxic sample (4.8 ± 0.5 ppm oxygen) released 2.4 ± 0.4 times more ATP than the normoxic sample (8.4 ± 0.6 ppm oxygen). Importantly, the results reported here verify the reproducible and transferable nature of using 3D printing as a fabrication technique, as devices and electrodes were moved between labs multiple times during completion of the study.
Collapse
Affiliation(s)
- Jayda L Erkal
- Department of Chemistry, Michigan State University, 578 S. Shaw Lane, East Lansing, MI 48824, USA.
| | | | | | | | | | | | | | | |
Collapse
|
30
|
Selimovic A, Martin RS. Encapsulated electrodes for microchip devices: microarrays and platinized electrodes for signal enhancement. Electrophoresis 2013; 34:2092-100. [PMID: 23670668 PMCID: PMC3760495 DOI: 10.1002/elps.201300163] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2013] [Revised: 04/10/2013] [Accepted: 04/10/2013] [Indexed: 12/20/2022]
Abstract
In this paper, we present two new methodologies of improving the performance of microchip-based electrochemical detection in microfluidic devices. The first part describes the fabrication and characterization of epoxy-embedded gold microelectrode arrays that are evenly spaced and easily modified. Electrodepositions using a gold plating solution can be performed on the electrodes to result in a 3D pillar array that, when used with microchip-based flow injection analysis, leads to an eightfold increase in signal (when compared to a single electrode), with the LOD for catechol being 4 nM. For detecting analytically challenging molecules such as nitric oxide (NO), platinization of electrodes is commonly used to increase the sensitivity. It is shown here that microchip devices containing either the pillar arrays or more traditional glassy carbon electrodes can be modified with platinum black (Pt-black) for NO detection. In the case of using glassy carbon electrodes for NO detection, integration of the resulting platinized electrode with microchip-based flow analysis resulted in a ten times signal increase relative to use of a bare glassy carbon electrode. In addition, it is demonstrated that these electrodes can be coated with Nafion to impart selectivity toward NO over interfering species such as nitrite. The LOD for NO when using the Pt-black /Nafion-coated glassy carbon electrode was 9 nM. These electrodes can also be embedded in a polystyrene substrate, with the applicability of these sensitive and selective electrodes being demonstrated by monitoring the adenosine triphosphate-mediated release of NO from endothelial cells immobilized in a microfluidic network without any adhesion factor.
Collapse
Affiliation(s)
- Asmira Selimovic
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - R. Scott Martin
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| |
Collapse
|
31
|
Croushore CA, Sweedler JV. Microfluidic systems for studying neurotransmitters and neurotransmission. LAB ON A CHIP 2013; 13:1666-76. [PMID: 23474943 PMCID: PMC3632338 DOI: 10.1039/c3lc41334a] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Neurotransmitters and neuromodulators are molecules within the nervous system that play key roles in cell-to-cell communication. Upon stimulation, neurons release these signaling molecules, which then act at local or distant locations to elicit a physiological response. Ranging from small molecules, such as diatomic gases and amino acids, to larger peptides, these chemical messengers are involved in many functional processes including growth, reproduction, memory and behavior. Understanding signaling molecules and the conditions that govern their release in healthy or damaged networks promises to deliver insights into neural network formation and function. Microfluidic devices can provide optimal cell culture conditions, reduced volume systems, and precise control over the chemical and physical nature of the extracellular environment, making them well-suited for studying neurotransmission and other forms of cell-to-cell signaling. Here we review selected microfluidic approaches that are suitable for monitoring cell-to-cell signaling molecules. We highlight devices that improve in vivo sample collection as well as compartmentalized devices designed to isolate individual neurons or co-cultures in vitro, including a focus on systems used for studying neural injury and regeneration, and devices that allow selective chemical stimulations and the characterization of released molecules.
Collapse
Affiliation(s)
- Callie A. Croushore
- Department of Chemistry and the Beckman Institute for Advanced Science
and Technology, University of Illinois at Urbana-Champaign, Urbana IL 61801,
USA
| | - Jonathan V. Sweedler
- Department of Chemistry and the Beckman Institute for Advanced Science
and Technology, University of Illinois at Urbana-Champaign, Urbana IL 61801,
USA
| |
Collapse
|
32
|
Microchip-based electrochemical detection for monitoring cellular systems. Anal Bioanal Chem 2013; 405:3013-20. [PMID: 23340999 DOI: 10.1007/s00216-012-6682-3] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2012] [Revised: 12/13/2012] [Accepted: 12/19/2012] [Indexed: 01/09/2023]
Abstract
The use of microchip devices to study cellular systems is a rapidly growing research area. There are numerous advantages of using on-chip integrated electrodes to monitor various cellular processes. The purpose of this review is to give examples of advancements in microchip-based cellular analysis, specifically where electrochemistry is used for the detection scheme. These examples include on-chip detection of single-cell quantal exocytosis, electrochemical analysis of intracellular contents, the ability to integrate cell culture/immobilization with electrochemistry, and the use of integrated electrodes to ensure cell confluency in longer-term cell culture experiments. A perspective on future trends in this area is also given.
Collapse
|
33
|
Saito RM, Coltro WKT, de Jesus DP. Instrumentation design for hydrodynamic sample injection in microchip electrophoresis: a review. Electrophoresis 2012; 33:2614-23. [PMID: 22965705 DOI: 10.1002/elps.201200089] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Reproducible and representative sample injection in microchip electrophoresis has been a bottleneck for quantitative analytical applications. Electrokinetic sample injection is the most used because it is easy to perform. However, this injection method is usually affected by sample composition and the bias effect. On the other hand, these drawbacks are overcome by the hydrodynamic (HD) sample injection, although this injection mode requires HD flow control. This review gives an overview of the basic principles, the instrumentation designs, and the performance of HD sample injection systems for microchip electrophoresis.
Collapse
Affiliation(s)
- Renata M Saito
- Institute of Chemistry, State University of Campinas, Campinas, São Paulo, Brazil
| | | | | |
Collapse
|
34
|
Johnson AS, Anderson KB, Halpin ST, Kirkpatrick DC, Spence DM, Martin RS. Integration of multiple components in polystyrene-based microfluidic devices part I: fabrication and characterization. Analyst 2012; 138:129-36. [PMID: 23120747 DOI: 10.1039/c2an36168j] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
In Part I of a two-part series, we describe a simple and inexpensive approach to fabricate polystyrene devices that is based upon melting polystyrene (from either a Petri dish or powder form) against PDMS molds or around electrode materials. The ability to incorporate microchannels in polystyrene and integrate the resulting device with standard laboratory equipment such as an optical plate reader for analyte readout and pipets for fluid propulsion is first described. A simple approach for sample and reagent delivery to the device channels using a standard, multi-channel micropipette and a PDMS-based injection block is detailed. Integration of the microfluidic device with these off-chip functions (sample delivery and readout) enables high-throughput screens and analyses. An approach to fabricate polystyrene-based devices with embedded electrodes is also demonstrated, thereby enabling the integration of microchip electrophoresis with electrochemical detection through the use of a palladium electrode (for a decoupler) and carbon-fiber bundle (for detection). The device was sealed against a PDMS-based microchannel and used for the electrophoretic separation and amperometric detection of dopamine, epinephrine, catechol, and 3,4-dihydroxyphenylacetic acid. Finally, these devices were compared against PDMS-based microchips in terms of their optical transparency and absorption of an anti-platelet drug, clopidogrel. Part I of this series lays the foundation for Part II, where these devices were utilized for various on-chip cellular analysis.
Collapse
Affiliation(s)
- Alicia S Johnson
- Department of Chemistry, Saint Louis University, St. Louis, Missouri 63103, USA
| | | | | | | | | | | |
Collapse
|
35
|
Anderson KB, Halpin ST, Johnson AS, Martin RS, Spence DM. Integration of multiple components in polystyrene-based microfluidic devices part II: cellular analysis. Analyst 2012; 138:137-43. [PMID: 23120748 DOI: 10.1039/c2an36171j] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
In Part II of this series describing the use of polystyrene (PS) devices for microfluidic-based cellular assays: various cellular types and detection strategies are employed to determine three fundamental assays often associated with cells. Specifically, using either integrated electrochemical sensing or optical measurements with a standard multi-well plate reader, cellular uptake, production, or release of important cellular analytes are determined on a PS-based device. One experiment involved the fluorescence measurement of nitric oxide (NO) produced within an endothelial cell line following stimulation with ATP. The result was a four-fold increase in NO production (as compared to a control), with this receptor-based mechanism of NO production verifying the maintenance of cell receptors following immobilization onto the PS substrate. The ability to monitor cellular uptake was also demonstrated by optical determination of Ca(2+) into endothelial cells following stimulation with the Ca(2+) ionophore A20317. The result was a significant increase (42%) in the calcium uptake in the presence of the ionophore, as compared to a control (17%) (p < 0.05). Finally, the release of catecholamines from a dopaminergic cell line (PC 12 cells) was electrochemically monitored, with the electrodes being embedded into the PS-based device. The PC 12 cells had better adherence on the PS devices, as compared to use of PDMS. Potassium-stimulation resulted in the release of 114 ± 11 μM catecholamines, a significant increase (p < 0.05) over the release from cells that had been exposed to an inhibitor (reserpine, 20 ± 2 μM of catecholamines). The ability to successfully measure multiple analytes, generated in different means from various cells under investigation, suggests that PS may be a useful material for microfluidic device fabrication, especially considering the enhanced cell adhesion to PS, its enhanced rigidity/amenability to automation, and its ability to enable a wider range of analytes to be investigated, even analytes with a high degree of hydrophobicity.
Collapse
Affiliation(s)
- Kari B Anderson
- Department of Chemistry, Michigan State University, 578 S. Shaw Blvd, East Lansing, Michigan 48824, USA
| | | | | | | | | |
Collapse
|
36
|
Yang L, Li X, Li J, Yuan H, Zhao S, Xiao D. Small-angle optical deflection from collinear configuration for sensitive detection in microfluidic systems. Electrophoresis 2012; 33:1996-2004. [DOI: 10.1002/elps.201100442] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Affiliation(s)
- Li Yang
- College of Chemistry and College of Chemical Engineering; Sichuan University; Chengdu; P. R. China
| | - Xiangtang Li
- College of Chemistry and College of Chemical Engineering; Sichuan University; Chengdu; P. R. China
| | - Jing Li
- College of Chemistry and College of Chemical Engineering; Sichuan University; Chengdu; P. R. China
| | - Hongyan Yuan
- College of Chemistry and College of Chemical Engineering; Sichuan University; Chengdu; P. R. China
| | - Shulin Zhao
- College of Chemistry and Chemical Engineering; Guangxi Normal University; Guilin; P. R. China
| | - Dan Xiao
- College of Chemistry and College of Chemical Engineering; Sichuan University; Chengdu; P. R. China
| |
Collapse
|
37
|
Sasaki N, Shinjo M, Hirakawa S, Nishinaka M, Tanaka Y, Mawatari K, Kitamori T, Sato K. A palmtop-sized microfluidic cell culture system driven by a miniaturized infusion pump. Electrophoresis 2012; 33:1729-35. [DOI: 10.1002/elps.201100691] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Affiliation(s)
- Naoki Sasaki
- Department of Chemical and Biological Sciences; Faculty of Science, Japan Women's University; Mejirodai, Bunkyo-ku; Tokyo; Japan
| | - Mika Shinjo
- Department of Chemical and Biological Sciences; Faculty of Science, Japan Women's University; Mejirodai, Bunkyo-ku; Tokyo; Japan
| | - Satoshi Hirakawa
- Department of Dermatology; Hamamatsu University School of Medicine, Handayama; Higashi-ku, Hamamatsu, Shizuoka; Japan
| | - Masahiro Nishinaka
- Department of Applied Chemistry; Graduate School of Engineering, The University of Tokyo; Hongo, Bunkyo-ku; Tokyo; Japan
| | - Yo Tanaka
- Department of Applied Chemistry; Graduate School of Engineering, The University of Tokyo; Hongo, Bunkyo-ku; Tokyo; Japan
| | | | | | | |
Collapse
|
38
|
Karlinsey JM. Sample introduction techniques for microchip electrophoresis: A review. Anal Chim Acta 2012; 725:1-13. [DOI: 10.1016/j.aca.2012.02.052] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2011] [Revised: 02/25/2012] [Accepted: 02/29/2012] [Indexed: 12/24/2022]
|
39
|
Johnson AS, Selimovic A, Martin RS. Integration of microchip electrophoresis with electrochemical detection using an epoxy-based molding method to embed multiple electrode materials. Electrophoresis 2011; 32:3121-8. [PMID: 22038707 PMCID: PMC3314886 DOI: 10.1002/elps.201100433] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2011] [Revised: 09/01/2011] [Accepted: 09/02/2011] [Indexed: 11/08/2022]
Abstract
This paper describes the use of epoxy-encapsulated electrodes to integrate microchip-based electrophoresis with electrochemical detection. Devices with various electrode combinations can easily be developed. This includes a palladium decoupler with a downstream working electrode material of either gold, mercury/gold, platinum, glassy carbon, or a carbon fiber bundle. Additional device components such as the platinum wires for the electrophoresis separation and the counter electrode for detection can also be integrated into the epoxy base. The effect of the decoupler configuration was studied in terms of the separation performance, detector noise, and the ability to analyze samples of a high ionic strength. The ability of both glassy carbon and carbon fiber bundle electrodes to analyze a complex mixture was demonstrated. It was also shown that a PDMS-based valving microchip can be used along with the epoxy-embedded electrodes to integrate microdialysis sampling with microchip electrophoresis and electrochemical detection, with the microdialysis tubing also being embedded in the epoxy substrate. This approach enables one to vary the detection electrode material as desired in a manner where the electrodes can be polished and modified as is done with electrochemical flow cells used in liquid chromatography.
Collapse
Affiliation(s)
- Alicia S. Johnson
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - Asmira Selimovic
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - R. Scott Martin
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| |
Collapse
|
40
|
Experimental and numerical analysis of high-resolution injection technique for capillary electrophoresis microchip. Int J Mol Sci 2011; 12:3594-605. [PMID: 21747696 PMCID: PMC3131580 DOI: 10.3390/ijms12063594] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2011] [Revised: 05/11/2011] [Accepted: 05/25/2011] [Indexed: 12/15/2022] Open
Abstract
This study presents an experimental and numerical investigation on the use of high-resolution injection techniques to deliver sample plugs within a capillary electrophoresis (CE) microchip. The CE microfluidic device was integrated into a U-shaped injection system and an expansion chamber located at the inlet of the separation channel, which can miniize the sample leakage effect and deliver a high-quality sample plug into the separation channel so that the detection performance of the device is enhanced. The proposed 45° U-shaped injection system was investigated using a sample of Rhodamine B dye. Meanwhile, the analysis of the current CE microfluidic chip was studied by considering the separation of Hae III digested ϕx-174 DNA samples. The experimental and numerical results indicate that the included 45° U-shaped injector completely eliminates the sample leakage and an expansion separation channel with an expansion ratio of 2.5 delivers a sample plug with a perfect detection shape and highest concentration intensity, hence enabling an optimal injection and separation performance.
Collapse
|
41
|
Sun X, Kelly RT, Danielson WF, Agrawal N, Tang K, Smith RD. Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilization. Electrophoresis 2011; 32:1610-8. [PMID: 21520147 DOI: 10.1002/elps.201000522] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2010] [Revised: 12/01/2010] [Accepted: 12/29/2010] [Indexed: 11/06/2022]
Abstract
A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip CE separations. The PDMS devices used for the evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~ 100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersection geometry, the solution back pressure, and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to > 2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 10³ theoretical plates for the ~2.4-cm-long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, little sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations for multiplexing CE separations and for sample-limited bioanalyses are discussed.
Collapse
Affiliation(s)
- Xuefei Sun
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA, USA
| | | | | | | | | | | |
Collapse
|
42
|
Selimovic A, Johnson AS, Kiss IZ, Martin RS. Use of epoxy-embedded electrodes to integrate electrochemical detection with microchip-based analysis systems. Electrophoresis 2011; 32:822-31. [PMID: 21413031 PMCID: PMC3085833 DOI: 10.1002/elps.201000665] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2010] [Revised: 01/11/2011] [Accepted: 01/11/2011] [Indexed: 11/09/2022]
Abstract
A new method of fabricating electrodes for microchip devices that involves the use of Teflon molds and a commercially available epoxy to embed electrodes of various sizes and compositions is described. The resulting epoxy base can be polished to generate a fresh electrode and sealed against poly(dimethylsiloxane) (PDMS)-based fluidic structures. Microchip-based flow injection analysis was used to characterize the epoxy-embedded electrodes. It was shown that gold electrodes can be amalgamated with liquid mercury and the resulting mercury/gold electrode is used to selectively detect glutathione from lysed red blood cells. The ability to encapsulate multiple electrode materials of differing compositions enabled the integration of microchip electrophoresis with electrochemical detection. Finally, a unique feature of this approach is that the electrode connection is made from the bottom of the epoxy base. This enables the creation of three-dimensional gold pillar electrodes (65 μm in diameter and 27 μm in height) that can be integrated within a fluidic network. As compared with the use of a flat electrode of a similar diameter, the use of the pillar electrode led to improvements in both the sensitivity (72.1 pA/μM for the pillar versus 4.2 pA/μM for the flat electrode) and limit of detection (20 nM for the pillar versus 600 nM for the flat electrode), with catechol being the test analyte. These epoxy-embedded electrodes hold promise for the creation of inexpensive microfluidic devices that can be used to electrochemically detect biologically important analytes in a manner where the electrodes can be polished and a fresh electrode surface is generated as desired.
Collapse
Affiliation(s)
- Asmira Selimovic
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - Alicia S. Johnson
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - István Z. Kiss
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| | - R. Scott Martin
- Saint Louis University, Department of Chemistry, 3501 Laclede Avenue, St. Louis, MO 63103
| |
Collapse
|