1
|
Pade LR, Stepler KE, Portero EP, DeLaney K, Nemes P. Biological mass spectrometry enables spatiotemporal 'omics: From tissues to cells to organelles. MASS SPECTROMETRY REVIEWS 2024; 43:106-138. [PMID: 36647247 PMCID: PMC10668589 DOI: 10.1002/mas.21824] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 09/14/2022] [Accepted: 09/17/2022] [Indexed: 06/17/2023]
Abstract
Biological processes unfold across broad spatial and temporal dimensions, and measurement of the underlying molecular world is essential to their understanding. Interdisciplinary efforts advanced mass spectrometry (MS) into a tour de force for assessing virtually all levels of the molecular architecture, some in exquisite detection sensitivity and scalability in space-time. In this review, we offer vignettes of milestones in technology innovations that ushered sample collection and processing, chemical separation, ionization, and 'omics analyses to progressively finer resolutions in the realms of tissue biopsies and limited cell populations, single cells, and subcellular organelles. Also highlighted are methodologies that empowered the acquisition and analysis of multidimensional MS data sets to reveal proteomes, peptidomes, and metabolomes in ever-deepening coverage in these limited and dynamic specimens. In pursuit of richer knowledge of biological processes, we discuss efforts pioneering the integration of orthogonal approaches from molecular and functional studies, both within and beyond MS. With established and emerging community-wide efforts ensuring scientific rigor and reproducibility, spatiotemporal MS emerged as an exciting and powerful resource to study biological systems in space-time.
Collapse
Affiliation(s)
- Leena R. Pade
- Department of Chemistry & Biochemistry, University of Maryland, 8051 Regents Drive, College Park, MD 20742
| | - Kaitlyn E. Stepler
- Department of Chemistry & Biochemistry, University of Maryland, 8051 Regents Drive, College Park, MD 20742
| | - Erika P. Portero
- Department of Chemistry & Biochemistry, University of Maryland, 8051 Regents Drive, College Park, MD 20742
| | - Kellen DeLaney
- Department of Chemistry & Biochemistry, University of Maryland, 8051 Regents Drive, College Park, MD 20742
| | - Peter Nemes
- Department of Chemistry & Biochemistry, University of Maryland, 8051 Regents Drive, College Park, MD 20742
| |
Collapse
|
2
|
Pillai MS, Paritala ST, Shah RP, Sharma N, Sengupta P. Cutting-edge strategies and critical advancements in characterization and quantification of metabolites concerning translational metabolomics. Drug Metab Rev 2022; 54:401-426. [PMID: 36351878 DOI: 10.1080/03602532.2022.2125987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Despite remarkable progress in drug discovery strategies, significant challenges are still remaining in translating new insights into clinical applications. Scientists are devising creative approaches to bridge the gap between scientific and translational research. Metabolomics is a unique field among other omics techniques for identifying novel metabolites and biomarkers. Fortunately, characterization and quantification of metabolites are becoming faster due to the progress in the field of orthogonal analytical techniques. This review detailed the advancement in the progress of sample preparation, and data processing techniques including data mining tools, database, and their quality control (QC). Advances in data processing tools make it easier to acquire unbiased data that includes a diverse set of metabolites. In addition, novel breakthroughs including, miniaturization as well as their integration with other devices, metabolite array technology, and crystalline sponge-based method have led to faster, more efficient, cost-effective, and holistic metabolomic analysis. The use of cutting-edge techniques to identify the human metabolite, including biomarkers has proven to be advantageous in terms of early disease identification, tracking the progression of illness, and possibility of personalized treatments. This review addressed the constraints of current metabolomics research, which are impeding the facilitation of translation of research from bench to bedside. Nevertheless, the possible way out from such constraints and future direction of translational metabolomics has been conferred.
Collapse
Affiliation(s)
- Megha Sajakumar Pillai
- Department of Pharmaceutical Analysis, National Institute of Pharmaceutical Education and Research (NIPER), Ahmedabad, India
| | - Sree Teja Paritala
- Department of Pharmaceutical Analysis, National Institute of Pharmaceutical Education and Research (NIPER), Ahmedabad, India
| | - Ravi P Shah
- Department of Pharmaceutical Analysis, National Institute of Pharmaceutical Education and Research (NIPER), Ahmedabad, India
| | - Nitish Sharma
- Department of Pharmaceutical Analysis, National Institute of Pharmaceutical Education and Research (NIPER), Ahmedabad, India
| | - Pinaki Sengupta
- Department of Pharmaceutical Analysis, National Institute of Pharmaceutical Education and Research (NIPER), Ahmedabad, India
| |
Collapse
|
3
|
Elshamy YS, Strein TG, Holland LA, Li C, DeBastiani A, Valentine SJ, Li P, Lucas JA, Shaffer TA. Nanoflow Sheath Voltage-Free Interfacing of Capillary Electrophoresis and Mass Spectrometry for the Detection of Small Molecules. Anal Chem 2022; 94:11329-11336. [PMID: 35913997 PMCID: PMC9387528 DOI: 10.1021/acs.analchem.2c02074] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Coupling capillary electrophoresis (CE) to mass spectrometry (MS) is a powerful strategy to leverage a high separation efficiency with structural identification. Traditional CE-MS interfacing relies upon voltage to drive this process. Additionally, sheathless interfacing requires that the electrophoresis generates a sufficient volumetric flow to sustain the ionization process. Vibrating sharp-edge spray ionization (VSSI) is a new method to interface capillary electrophoresis to mass analyzers. In contrast to traditional interfacing, VSSI is voltage-free, making it straightforward for CE and MS. New nanoflow sheath CE-VSSI-MS is introduced in this work to reduce the reliance on the separation flow rate to facilitate the transfer of analyte to the MS. The nanoflow sheath VSSI spray ionization functions from 400 to 900 nL/min. Using the new nanoflow sheath reported here, volumetric flow rate through the separation capillary is less critical, allowing the use of a small (i.e., 20 to 25 μm) inner diameter separation capillary and enabling the use of higher separation voltages and faster analysis. Moreover, the use of a nanoflow sheath enables greater flexibility in the separation conditions. The nanoflow sheath is operated using aqueous solutions in the background electrolyte and in the sheath, demonstrating the separation can be performed under normal and reversed polarity in the presence or absence of electroosmotic flow. This includes the use of a wider pH range as well. The versatility of nanoflow sheath CE-VSSI-MS is demonstrated by separating cationic, anionic, and zwitterionic molecules under a variety of separation conditions. The detection sensitivity observed with nanoflow sheath CE-VSSI-MS is comparable to that obtained with sheathless CE-VSSI-MS as well as CE-MS separations with electrospray ionization interfacing. A bare fused silica capillary is used to separate cationic β-blockers with a near-neutral background electrolyte at concentrations ranging from 1.0 nM to 1.0 μM. Under acidic conditions, 13 amino acids are separated with normal polarity at a concentration ranging from 0.25 to 5 μM. Finally, separations of anionic compounds are demonstrated using reversed polarity under conditions of suppressed electroosmotic flow through the use of a semipermanent surface coating. With a near-neutral separation electrolyte, anionic nonsteroidal anti-inflammatory drugs are detected over a concentration range of 0.1 to 5.0 μM.
Collapse
Affiliation(s)
- Yousef S Elshamy
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26505, United States
| | - Timothy G Strein
- Department of Chemistry, Bucknell University, Lewisburg, Pennsylvania 17837, United States
| | - Lisa A Holland
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26505, United States
| | - Chong Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26505, United States
| | - Anthony DeBastiani
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26505, United States
| | - Stephen J Valentine
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26505, United States
| | - Peng Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26505, United States
| | - John A Lucas
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26505, United States
| | - Tyler A Shaffer
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26505, United States
| |
Collapse
|
4
|
Liu B, Wang W, Gao T, Huang L, Fan H, Chen HX. Separation, identification and quantification of associated impurities in cobratide using sheathless CE-MS and CE-UV. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:3845-3851. [PMID: 34378552 DOI: 10.1039/d1ay00717c] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Cobratide is a peptide drug extracted from the venom of Chinese cobra, and has been widely used in the clinical treatment of chronic, intractable and persistent pain. In a recent study, it was reported that it has the potential to treat COVID-19. In order to control the quality of commercial cobratide drugs, a protocol was established for the separation, identification and quantification of cobratide and its associated impurities, in which sheathless capillary electrophoresis-mass spectrometry (CE-MS) was used for identification and a rapid capillary electrophoresis-ultraviolet-visible detector (CE-UV) method was developed for accurate quantification. Separation conditions that affect the resolution and MS intensities of cobratide and its associated impurities were investigated, including pH value, concentration of background electrolyte (BGE), ratio of organic additive and sample solution. The optimized CE conditions (BGE: 50 mM NH4Ac, pH 4.0; sample solution: deionized water) were used for both sheathless CE-MS and CE-UV methods. Three associated impurities were separated and identified for the first time by sheathless CE-MS. Then, a rapid CE-UV method was validated and used for accurate quantification of cobratide and its associated impurities. The CE-UV method showed good linearity between concentration and corrected peak area of cobratide in the concentration range of 5.36-536.30 μg mL-1. The limit of quantification of the CE-UV method was 4.16 μg mL-1. The relative standard deviations of migration time were less than 1% for both intra-day and inter-day experiments, and those of corrected peak area were less than 5%. Finally, different cobratide drugs were analyzed to evaluate the batch-to-batch consistency. This established protocol combining sheathless CE-MS and CE-UV methods would provide useful information for both quality control and process analysis of peptide drugs.
Collapse
Affiliation(s)
- Bo Liu
- National Institutes for Food and Drug Control, 31st Huatuo Rd., Daxing Dist., Beijing 102629, P. R. China.
| | - Wentao Wang
- SCIEX China, 5F, Building 1, 24 Yard, Jiuxianqiao Mid Road, Chaoyang District, Beijing 100015, China.
| | - Tie Gao
- SCIEX China, 5F, Building 1, 24 Yard, Jiuxianqiao Mid Road, Chaoyang District, Beijing 100015, China.
| | - Lu Huang
- National Institutes for Food and Drug Control, 31st Huatuo Rd., Daxing Dist., Beijing 102629, P. R. China.
| | - Huihong Fan
- National Institutes for Food and Drug Control, 31st Huatuo Rd., Daxing Dist., Beijing 102629, P. R. China.
| | - Hong-Xu Chen
- SCIEX China, 5F, Building 1, 24 Yard, Jiuxianqiao Mid Road, Chaoyang District, Beijing 100015, China.
| |
Collapse
|
5
|
Ferré S, Drouin N, González-Ruiz V, Rudaz S. Evaluation of a nanoflow interface based on the triple-tube coaxial sheath-flow sprayer for capillary electrophoresis-mass spectrometry coupling in metabolomics. J Chromatogr A 2021; 1641:461982. [PMID: 33611118 DOI: 10.1016/j.chroma.2021.461982] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Revised: 02/03/2021] [Accepted: 02/07/2021] [Indexed: 02/06/2023]
Abstract
The performance of an original CE-MS interface that allows the in-axis positioning of the electrospray with respect to the MS inlet was evaluated. The variations in the geometrical alignment of this configuration in the absence of a nebulizing gas afforded a significant reduction in the sheath-liquid flow rate from 3 µL/min to as low as 300 nL/min. The sheath liquid and BGE were respectively composed of H2O-iPrOHCH3COOH 50:50:1 (v/v/v) and 10% acetic acid (pH 2.2). A significant gain in sensitivity was obtained, and it was correlated to the effective mobility of the analytes. Compounds with low mobility values showed a greater sensitivity gain. Special attention was paid to the detection of proteinogenic amino acids. Linear response functions were obtained from 15 ng/mL to 500 ng/mL. The limits of quantification, as low as 34.3 ng/mL, were improved by a factor of up to six compared to the conventional configuration. The in-axis setup was ultimately applied to the absolute quantification of four important amino acids, alanine, tyrosine, methionine and valine, in standard reference material (NIST plasma). The accuracies ranged from 78 to 113%, thus demonstrating the potential of this configuration for metabolomics.
Collapse
Affiliation(s)
- Sabrina Ferré
- School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland
| | - Nicolas Drouin
- School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland
| | - Víctor González-Ruiz
- School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland; Swiss Centre for Applied Human Toxicology (SCAHT), Switzerland
| | - Serge Rudaz
- School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland; Swiss Centre for Applied Human Toxicology (SCAHT), Switzerland.
| |
Collapse
|
6
|
Vermeire PJ, Van Schepdael A, Petersen NJ. Development of a novel sheathless CE-ESI-MS interface via a CO 2 laser ablated opening. Talanta 2020; 214:120853. [PMID: 32278416 DOI: 10.1016/j.talanta.2020.120853] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2019] [Revised: 02/13/2020] [Accepted: 02/15/2020] [Indexed: 11/18/2022]
Abstract
A new and easy to construct sheathless capillary electrophoresis electro spray ionization mass spectrometry (CE-ESI-MS) interface was developed that offers several advantages compared to traditional liquid junction interfaces. The fabrication of the device only requires a CO2 laser engraver that most groups working with microfluids have access to. It only takes a few seconds to create a CO2 laser ablated opening in the bare-fused silica capillaries and the opening can be placed as close as a few mm from the spray tip. The capillary is punctured through a silicone tube such that the opening is directly placed inside this tube, which also serves as a liquid reservoir for the make-up liquid. Electrical contact required for both CE separation and ESI is established via the liquid in this reservoir which is in contact with the electrode of an external high voltage power supply. The developed CE-ESI-MS interface is capable of analysing both small molecules and biomolecules such as peptides in physisorbed PEG polymer brush coated capillaries. Proof-of-principle of the interface was demonstrated by analysing a tryptic digest of BSA. Further, a range of drugs of abuse were also investigated. The examined small molecules (pethidine, nortriptyline, methadone, haloperidol and loperamide) have a quantification limit (LOQ) of 150 ng/mL and a detection limit (LOD) of 40 ng/mL (except for loperamide: LOD = 80 ng/mL). Finally, we used our novel CE-MS interface for the analysis of the Aβ40 peptide. This is a member of the beta-Amyloid peptide family, involved in the development of Alzheimer's disease. A LOQ of 9 μg/mL was obtained for Aβ40, corresponding to 23 fmoles in a sample volume of 11 nL.
Collapse
Affiliation(s)
- Pieter-Jan Vermeire
- Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49, O&N2 PB 822, 3000, Leuven, Belgium.
| | - Ann Van Schepdael
- Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49, O&N2 PB 822, 3000, Leuven, Belgium
| | - Nickolaj J Petersen
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, DK-2100, Copenhagen, Denmark
| |
Collapse
|
7
|
He H, Tian M, Hu L, Yang L. Ultrasensitive determination of organotin compounds in plastic food packaging and edible oils by sheathless capillary electrophoresis-electrospray ionization-mass spectrometry. Analyst 2020; 145:2286-2296. [PMID: 32003368 DOI: 10.1039/c9an02331c] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
The determination of trace-amount organotins in plastic food packaging materials is of great significance in food safety. However, due to the complexity of organotins and sample treatment processes, it is still a challenging task. Here, we report a method for the sensitive and simultaneous determination of organotins in plastic food packaging materials and edible oils, by utilizing sheathless capillary electrophoresis-electrospray ionization-mass spectrometry. The method of sample pretreatment with ultrasonic extraction and solid phase extraction is used to eliminate interference. The results showed low limits of detection (LODs) of 2 pg mL-1-50 pg mL-1 and excellent inter/intra-day repeatability. Good average recoveries in the range of 80.27% to 108.52% were obtained at three spiked concentrations, with a relative standard deviation less than 8.71%. The successful simultaneous determination of the target analytes will pave the way for further assessment of contamination and migration behaviour of organotins from packaging materials to food, which is of great significance for evaluating and controlling food safety.
Collapse
Affiliation(s)
- Huiyu He
- Department of Chemistry, Northeast Normal University, 5268 Renmin Street, Changchun, Jilin Province 130024, PR China.
| | | | | | | |
Collapse
|
8
|
Gomes FP, Yates JR. Recent trends of capillary electrophoresis-mass spectrometry in proteomics research. MASS SPECTROMETRY REVIEWS 2019; 38:445-460. [PMID: 31407381 PMCID: PMC6800771 DOI: 10.1002/mas.21599] [Citation(s) in RCA: 61] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Progress in proteomics research has led to a demand for powerful analytical tools with high separation efficiency and sensitivity for confident identification and quantification of proteins, posttranslational modifications, and protein complexes expressed in cells and tissues. This demand has significantly increased interest in capillary electrophoresis-mass spectrometry (CE-MS) in the past few years. This review provides highlights of recent advances in CE-MS for proteomics research, including a short introduction to top-down mass spectrometry and native mass spectrometry (native MS), as well as a detailed overview of CE methods. Both the potential and limitations of these methods for the analysis of proteins and peptides in synthetic and biological samples and the challenges of CE methods are discussed, along with perspectives about the future direction of CE-MS. @ 2019 Wiley Periodicals, Inc. Mass Spec Rev 00:1-16, 2019.
Collapse
Affiliation(s)
| | - John R. Yates
- Correspondent author: , Phone number: (858) 784-8862, Departments of Molecular Medicine and Neurobiology, 10550 North Torrey Pines Road, SR302B, The Scripps Research Institute, La Jolla, CA 92037
| |
Collapse
|
9
|
Zhang F, Hong J, Xu W, Qu F. Straight nano-electrospray ionization and its coupling of mobility capillary electrophoresis to mass spectrometry. Talanta 2019; 206:120183. [PMID: 31514879 DOI: 10.1016/j.talanta.2019.120183] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Revised: 07/24/2019] [Accepted: 07/26/2019] [Indexed: 12/18/2022]
Abstract
Mobility capillary electrophoresis (MCE) was developed previously in our group, which has the capabilities of ion separation and biomolecule hydrodynamic radius analysis. The coupling of MCE with mass spectrometry (MS) would greatly improve complex sample identification capability as well as system detection sensitivity. In the present study, a simple and robust ionization source, named as straight nano-electrospray ionization (nanoESI) source was developed, which was applied to couple MCE with MS. A stainless-steel needle attached directly at the end of an MCE capillary was used as the nanoESI emitter, and the connection between this emitter to the liquid flow in the MCE separation channel was established through a liquid bridge. After optimization, this straight nanoESI source enhanced the ion signal intensity by ~10 times when compared with a commercial nanoESI source. The MCE-straight nanoESI-MS system was also characterized in terms of mixture separation and peptide hydrodynamic radius measurements. Compared to our previous work when a UV detector was used in a commercial Lumex CE system (model Capel 105 M, St. Petersburg, Russia), peptides with much lower concentrations could be analyzed (from ~1 mg/mL to ~20 μg/mL) in terms of radius measurement.
Collapse
Affiliation(s)
- Fei Zhang
- School of Life Science, Beijing Institute of Technology, Beijing, 100081, China
| | - Jie Hong
- School of Life Science, Beijing Institute of Technology, Beijing, 100081, China
| | - Wei Xu
- School of Life Science, Beijing Institute of Technology, Beijing, 100081, China.
| | - Feng Qu
- School of Life Science, Beijing Institute of Technology, Beijing, 100081, China.
| |
Collapse
|
10
|
Gahoual R, Leize-Wagner E, Houzé P, François YN. Revealing the potential of capillary electrophoresis/mass spectrometry: the tipping point. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2019; 33 Suppl 1:11-19. [PMID: 30022554 DOI: 10.1002/rcm.8238] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Revised: 07/04/2018] [Accepted: 07/11/2018] [Indexed: 06/08/2023]
Abstract
The hyphenation of capillary electrophoresis and mass spectrometry (CE/MS) remains a minor technique compared with liquid chromatography/mass spectrometry (LC/MS), which represents nowadays the standard instrumentation, regardless of its introduction thirty years ago. However, from a theoretical point of view, CE coupling should be quite favorable especially with electrospray ionization mass spectrometry (ESI-MS). At the time, the sensitivity provided by CE/MS was often limited, due to hyphenation requirements, which at some point appeared to disqualify CE/MS from benefiting from the performance gain driving the evolution of MS instruments. However, this context has been significantly modified in a matter of a few years. The development of innovative CE/MS interfacing systems has enabled an important improvement regarding sensitivity and reinforced robustness in order to provide an instrumentation accessible to the largest scientific community. Because of the unique selectivity delivered by the electrophoretic separation, CE/MS has proved to be particularly relevant for the analysis of biological molecules. The conjunction of these aspects is motivating the interest in CE/MS analysis and shows that CE/MS is mature enough to enrich the toolbox of analytical techniques for the analysis of complex biological samples. Here we discuss the characteristics of the major types of high-sensitivity CE/ESI-MS instrumentation and emphasize the late evolution and future positioning of CE/MS analysis for the characterization of biological molecules like peptides and proteins, through some pertinent applications.
Collapse
Affiliation(s)
- Rabah Gahoual
- Unité de Technologies Biologiques et Chimiques pour la Santé (UTCBS), Paris 5-CNRS UMR8258 Inserm U1022, Faculté de Pharmacie, Université Paris Descartes, Paris, France
| | - Emmanuelle Leize-Wagner
- Laboratoire de spectrométrie de masse des interactions et des systèmes (LSMIS), Unistra-CNRS UMR7140, Université de Strasbourg, Strasbourg, France
| | - Pascal Houzé
- Unité de Technologies Biologiques et Chimiques pour la Santé (UTCBS), Paris 5-CNRS UMR8258 Inserm U1022, Faculté de Pharmacie, Université Paris Descartes, Paris, France
- Laboratoire de Biochimie, Hôpital Universitaire Necker-Enfants malades, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France
| | - Yannis-Nicolas François
- Laboratoire de spectrométrie de masse des interactions et des systèmes (LSMIS), Unistra-CNRS UMR7140, Université de Strasbourg, Strasbourg, France
| |
Collapse
|
11
|
Krenkova J, Kleparnik K, Luksch J, Foret F. Microfabricated liquid junction hybrid capillary electrophoresis-mass spectrometry interface for fully automated operation. Electrophoresis 2019; 40:2263-2270. [PMID: 30794321 DOI: 10.1002/elps.201900049] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2019] [Revised: 02/18/2019] [Accepted: 02/19/2019] [Indexed: 11/07/2022]
Abstract
One of the challenging instrumental aspects in coupling an automated CE instrument with ESI mass spectrometry (CE-MS) is finding the balance between the stability, reproducibility and sensitivity of the analysis and compatibility with the standard CE instrumentation. Here, we present a development of a new liquid junction based electrospray interface for automated CE-MS, with a focus on the technical design followed by computer modeling of transport conditions as well as characterization of basic performance of the interface. This hybrid arrangement designed as a microfabricated unit attachable to the automated CE instrument allows using of a wide range of separation capillaries with respect to their diameter, length or internal coating (e.g., for suppressed electroosmotic flow). Different compositions of the ESI liquid and background electrolyte solutions can be used if needed. The microfabricated part, prepared by laser machining from polyimide, includes a self-aligning liquid junction, a short transport channel, and a pointed sprayer for the electrospray ionization. This microfabricated part is positioned in a plastic connection block securing the separation capillary and flushing ports. Transport conditions were modelled using computer simulation and the real life performance of the interface was compared to that of a commercial sheath liquid interface. The basic performance of the interface was demonstrated by separations of peptides, proteins, and oligosaccharides.
Collapse
Affiliation(s)
- Jana Krenkova
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Brno, Czech Republic
| | - Karel Kleparnik
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Brno, Czech Republic
| | - Jaroslav Luksch
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Brno, Czech Republic
| | - Frantisek Foret
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Brno, Czech Republic.,CEITEC Masaryk University, Brno, Czech Republic
| |
Collapse
|
12
|
Ramautar R. Sheathless Capillary Electrophoresis-Mass Spectrometry for the Profiling of Charged Metabolites in Biological Samples. Methods Mol Biol 2019; 1738:183-192. [PMID: 29654590 DOI: 10.1007/978-1-4939-7643-0_12] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Capillary electrophoresis (CE) is well suited for the profiling of highly polar and charged metabolites as compounds are separated on the basis of their charge-to-size ratio. The protocol presented here is based on using a recently developed sheathless interfacing design, i.e., a porous tip interface, for coupling CE to electrospray ionization mass spectrometry (MS). It is demonstrated that sheathless CE-MS employing a bare fused-silica capillary at low-pH separation conditions can be used for the profiling of both cationic and anionic metabolites by only switching the MS detection and electrophoretic separation voltage polarity. The proposed sheathless CE-MS protocol allows efficient and sensitive profiles to be obtained for a broad array of charged metabolites, including amino acids, organic acids, nucleotides, and sugar phosphates, in various biological samples, such as urine and extracts of the glioblastoma cell line.
Collapse
Affiliation(s)
- Rawi Ramautar
- Leiden Academic Center for Drug Research, Leiden University, Leiden, The Netherlands.
| |
Collapse
|
13
|
Holtkamp HU, Morrow SJ, Kubanik M, Hartinger CG. Hyphenation of capillary electrophoresis to inductively coupled plasma mass spectrometry with a modified coaxial sheath-flow interface. J Chromatogr A 2018; 1561:76-82. [PMID: 29798804 DOI: 10.1016/j.chroma.2018.05.036] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2018] [Revised: 05/14/2018] [Accepted: 05/15/2018] [Indexed: 12/23/2022]
Abstract
Capillary electrophoretic analyses benefit significantly from hyphenation to mass spectrometric techniques. While the coupling to ESI-MS is routinely performed, for example by using a coaxial sheath-flow interface, hyphenating it to inductively coupled plasma mass spectrometry is more technically challenging. We use a commercially available coaxial sheath-flow interface (CSFI) and a simple PTFE-based end-cap for easy, inexpensive CE-ICP-MS hyphenation with improved sensitivity and analytical performance compared to commercially available interfaces. We have optimized key nebulizer parameters such as capillary position, sheath liquid flow rate, and carrier gas flow rate, and compared the CSFI with a commercially available interface. In a set of proof-of-principle experiments employing the anticancer agent cisplatin it was demonstrated that the signal to noise response and sensitivity were considerably improved leading to detection limits for 195Pt of 0.08 μM.
Collapse
Affiliation(s)
- Hannah U Holtkamp
- University of Auckland, School of Chemical Sciences, Private Bag 92019, Auckland 1142, New Zealand(1)
| | - Stuart J Morrow
- University of Auckland, School of Chemical Sciences, Private Bag 92019, Auckland 1142, New Zealand(1)
| | - Mario Kubanik
- University of Auckland, School of Chemical Sciences, Private Bag 92019, Auckland 1142, New Zealand(1)
| | - Christian G Hartinger
- University of Auckland, School of Chemical Sciences, Private Bag 92019, Auckland 1142, New Zealand(1).
| |
Collapse
|
14
|
Chetwynd AJ, Guggenheim EJ, Briffa SM, Thorn JA, Lynch I, Valsami-Jones E. Current Application of Capillary Electrophoresis in Nanomaterial Characterisation and Its Potential to Characterise the Protein and Small Molecule Corona. NANOMATERIALS (BASEL, SWITZERLAND) 2018; 8:E99. [PMID: 29439415 PMCID: PMC5853730 DOI: 10.3390/nano8020099] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/05/2018] [Revised: 01/22/2018] [Accepted: 01/30/2018] [Indexed: 12/11/2022]
Abstract
Due to the increasing use and production of nanomaterials (NMs), the ability to characterise their physical/chemical properties quickly and reliably has never been so important. Proper characterisation allows a thorough understanding of the material and its stability, and is critical to establishing dose-response curves to ascertain risks to human and environmental health. Traditionally, methods such as Transmission Electron Microscopy (TEM), Field Flow Fractionation (FFF) and Dynamic Light Scattering (DLS) have been favoured for size characterisation, due to their wide-availability and well-established protocols. Capillary Electrophoresis (CE) offers a faster and more cost-effective solution for complex dispersions including polydisperse or non-spherical NMs. CE has been used to rapidly separate NMs of varying sizes, shapes, surface modifications and compositions. This review will discuss the literature surrounding the CE separation techniques, detection and NM characteristics used for the analysis of a wide range of NMs. The potential of combining CE with mass spectrometry (CE-MS) will also be explored to further expand the characterisation of NMs, including the layer of biomolecules adsorbed to the surface of NMs in biological or environmental compartments, termed the acquired biomolecule corona. CE offers the opportunity to uncover new/poorly characterised low abundance and polar protein classes due to the high ionisation efficiency of CE-MS. Furthermore, the possibility of using CE-MS to characterise the poorly researched small molecule interactions within the NM corona is discussed.
Collapse
Affiliation(s)
- Andrew J. Chetwynd
- AB Sciex UK Ltd., Phoenix House, Lakeside Drive, Warrington, Cheshire WA1 1RX, UK;
| | - Emily J. Guggenheim
- School of Geography Earth and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, UK; (E.J.G.); (S.M.B.); (E.V.-J.)
| | - Sophie M. Briffa
- School of Geography Earth and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, UK; (E.J.G.); (S.M.B.); (E.V.-J.)
| | - James A. Thorn
- AB Sciex UK Ltd., Phoenix House, Lakeside Drive, Warrington, Cheshire WA1 1RX, UK;
| | - Iseult Lynch
- School of Geography Earth and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, UK; (E.J.G.); (S.M.B.); (E.V.-J.)
| | - Eugenia Valsami-Jones
- School of Geography Earth and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, UK; (E.J.G.); (S.M.B.); (E.V.-J.)
| |
Collapse
|
15
|
González-Ruiz V, Codesido S, Rudaz S, Schappler J. Evolution in the design of a low sheath-flow interface for CE-MS and application to biological samples. Electrophoresis 2017; 39:853-861. [DOI: 10.1002/elps.201700328] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2017] [Revised: 10/20/2017] [Accepted: 10/21/2017] [Indexed: 12/14/2022]
Affiliation(s)
- Víctor González-Ruiz
- School of Pharmaceutical Sciences, University of Geneva; University of Lausanne; Geneva Switzerland
| | | | - Serge Rudaz
- School of Pharmaceutical Sciences, University of Geneva; University of Lausanne; Geneva Switzerland
| | - Julie Schappler
- School of Pharmaceutical Sciences, University of Geneva; University of Lausanne; Geneva Switzerland
| |
Collapse
|
16
|
Moreno-González D, Haselberg R, Gámiz-Gracia L, García-Campaña AM, de Jong GJ, Somsen GW. Fully compatible and ultra-sensitive micellar electrokinetic chromatography-tandem mass spectrometry using sheathless porous-tip interfacing. J Chromatogr A 2017; 1524:283-289. [PMID: 28992989 DOI: 10.1016/j.chroma.2017.09.075] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2017] [Revised: 09/26/2017] [Accepted: 09/30/2017] [Indexed: 11/26/2022]
Abstract
The on-line coupling of micellar electrokinetic chromatography and mass spectrometry (MEKC-MS) is often hampered by incompatibility problems leading to reduced separation performance and unfavorable limits of detection (LODs). Here we propose a new selective and highly sensitive MEKC-MS/MS method employing a sheathless porous-tip interface in combination with a micellar phase comprised of semi-volatile surfactant molecules. Carbamate pesticides (CRBs) were selected as representative model compounds being neutral toxic pollutants potentially present at trace levels in environmental water samples. A background electrolyte of 75mM perfluorooctanoic acid adjusted to pH 9.0 with ammonium hydroxide allowed efficient separation of 15 CRBs and appeared fully compatible with electrospray ionization (ESI)-MS. Interfacing parameters, such as the distance between the capillary tip and mass-spectrometer inlet, ESI voltage, and dry gas temperature and flow were optimized in order to attain good spray stability and high analyte signal-to-noise ratios. For CRBs the LODs ranged from 0.2 to 3.9ngL-1 (13nL injected, i.e., 2% of capillary volume), representing an improvement for certain CRBs of more than 300-fold when compared with conventional sheath-liquid interfacing. Good linearity (R2>0.99) and satisfactory reproducibility were obtained for all CRBs with interday RSD values for peak area and migration time of 4.0-11.3% and below 1.5%, respectively. Analysis of spiked mineral water showed that the new MEKC-MS/MS method allows selective and quantitative determination of CRB concentrations below the maximum residue limit of 100ngL-1 without the need for sample preconcentration.
Collapse
Affiliation(s)
- David Moreno-González
- Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Campus Fuentenueva, E-18071 Granada, Spain
| | - Rob Haselberg
- Division of BioAnalytical Chemistry, AIMMS research group BioMolecular Analysis, Faculty of Sciences, Vrije Universiteit Amsterdam, de Boelelaan 1085, 1081 HV Amsterdam, The Netherlands.
| | - Laura Gámiz-Gracia
- Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Campus Fuentenueva, E-18071 Granada, Spain
| | - Ana M García-Campaña
- Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Campus Fuentenueva, E-18071 Granada, Spain
| | - Gerhardus J de Jong
- Biomolecular Analysis, Utrecht University, Universiteitsweg 99, 3584 CG Utrecht, The Netherlands
| | - Govert W Somsen
- Division of BioAnalytical Chemistry, AIMMS research group BioMolecular Analysis, Faculty of Sciences, Vrije Universiteit Amsterdam, de Boelelaan 1085, 1081 HV Amsterdam, The Netherlands
| |
Collapse
|
17
|
Risley JM, Chen DDY. Improved sensitivity by post-column chemical environment modification of CE-ESI-MS using a flow-through microvial interface. Electrophoresis 2017; 38:1644-1648. [DOI: 10.1002/elps.201600545] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2016] [Revised: 02/10/2017] [Accepted: 03/21/2017] [Indexed: 01/21/2023]
Affiliation(s)
- Jessica May Risley
- Department of Chemistry; University of British Columbia; Vancouver BC Canada
| | - David Da Yong Chen
- Department of Chemistry; University of British Columbia; Vancouver BC Canada
| |
Collapse
|
18
|
Capillary electrophoresis mass spectrometry as a tool for untargeted metabolomics. Bioanalysis 2017; 9:99-130. [PMID: 27921456 DOI: 10.4155/bio-2016-0216] [Citation(s) in RCA: 62] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Highly polar and ionic metabolites, such as sugars, most amino acids, organic acids or nucleotides are not retained by conventional reversed-phase LC columns and polar stationary phases and hydrophilic-interaction LC lacks of robustness, which is still limiting their applications for untargeted metabolomics where reproducibility is a must. Biological samples such as blood, urine or even tissues include many hydrophilic compounds secreted from cells, their analysis is essential for biomarker discovery, disease progression or treatment effects. This review focuses on CE coupled to MS as a mature technique for untargeted metabolomics including sample pretreatment, types of matrices, analytical methods, applications and data treatment strategies for polar compound analysis in biological matrices. The main applications and results of CE-MS in untargeted metabolomics are discussed and presented in a tabulated format.
Collapse
|
19
|
Bertoletti L, Schappler J, Colombo R, Rudaz S, Haselberg R, Domínguez-Vega E, Raimondi S, Somsen GW, De Lorenzi E. Evaluation of capillary electrophoresis-mass spectrometry for the analysis of the conformational heterogeneity of intact proteins using beta 2-microglobulin as model compound. Anal Chim Acta 2016; 945:102-109. [PMID: 27968711 DOI: 10.1016/j.aca.2016.10.010] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2016] [Revised: 10/07/2016] [Accepted: 10/09/2016] [Indexed: 10/20/2022]
Abstract
In this work we explored the feasibility of different CE-ESI-MS set-ups for the analysis of conformational states of an intact protein. By using the same background electrolyte at quasi physiological conditions (50 mM ammonium bicarbonate, pH 7.4) a sequential optimization was carried out, initially by evaluating a sheath-liquid interface with both a single quadrupole (SQ) and a time-of-flight (TOF) mass spectrometer; then a sheathless interface coupled with high-resolution QTOF MS was considered. Beta2-microglobulin has been taken as a model, as it is an amyloidogenic protein and its conformational changes are strictly connected to the onset of a disease. The separation of two conformers at dynamic equilibrium is achieved all the way down to the MS detection. Notably, the equilibrium ratio of the protein conformers is maintained in the electrospray source after CE separation. Strengths and weaknesses of each optimized set-up are emphasized and their feasibility in unfolding studies is evaluated. In particular, ESI-TOF MS can assign protein forms that differ by 1 Da only and sheathless interfacing is best suited to preserve protein structure integrity. This demonstrates the CE-ESI-MS performance in terms of separation, detection and characterization of conformational species that co-populate a protein solution.
Collapse
Affiliation(s)
- Laura Bertoletti
- Department of Drug Sciences, University of Pavia, Viale Taramelli 12, 27100, Pavia, Italy.
| | - Julie Schappler
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU, Rue Michel Servet 1, 1211, Geneva 4, Switzerland.
| | - Raffaella Colombo
- Department of Drug Sciences, University of Pavia, Viale Taramelli 12, 27100, Pavia, Italy.
| | - Serge Rudaz
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU, Rue Michel Servet 1, 1211, Geneva 4, Switzerland.
| | - Rob Haselberg
- Division of BioAnalytical Chemistry, AIMMS Research Group BioMolecular Analysis, Vrije Universiteit Amsterdam, De Boelelaan 1085, 1081 HV, Amsterdam, The Netherlands.
| | - Elena Domínguez-Vega
- Division of BioAnalytical Chemistry, AIMMS Research Group BioMolecular Analysis, Vrije Universiteit Amsterdam, De Boelelaan 1085, 1081 HV, Amsterdam, The Netherlands.
| | - Sara Raimondi
- Department of Molecular Medicine, Institute of Biochemistry, University of Pavia, Viale Taramelli 3b, 27100, Pavia, Italy.
| | - Govert W Somsen
- Division of BioAnalytical Chemistry, AIMMS Research Group BioMolecular Analysis, Vrije Universiteit Amsterdam, De Boelelaan 1085, 1081 HV, Amsterdam, The Netherlands.
| | - Ersilia De Lorenzi
- Department of Drug Sciences, University of Pavia, Viale Taramelli 12, 27100, Pavia, Italy.
| |
Collapse
|
20
|
Hecht ES, Oberg AL, Muddiman DC. Optimizing Mass Spectrometry Analyses: A Tailored Review on the Utility of Design of Experiments. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:767-85. [PMID: 26951559 PMCID: PMC4841694 DOI: 10.1007/s13361-016-1344-x] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2015] [Revised: 01/14/2016] [Accepted: 01/16/2016] [Indexed: 05/07/2023]
Abstract
Mass spectrometry (MS) has emerged as a tool that can analyze nearly all classes of molecules, with its scope rapidly expanding in the areas of post-translational modifications, MS instrumentation, and many others. Yet integration of novel analyte preparatory and purification methods with existing or novel mass spectrometers can introduce new challenges for MS sensitivity. The mechanisms that govern detection by MS are particularly complex and interdependent, including ionization efficiency, ion suppression, and transmission. Performance of both off-line and MS methods can be optimized separately or, when appropriate, simultaneously through statistical designs, broadly referred to as "design of experiments" (DOE). The following review provides a tutorial-like guide into the selection of DOE for MS experiments, the practices for modeling and optimization of response variables, and the available software tools that support DOE implementation in any laboratory. This review comes 3 years after the latest DOE review (Hibbert DB, 2012), which provided a comprehensive overview on the types of designs available and their statistical construction. Since that time, new classes of DOE, such as the definitive screening design, have emerged and new calls have been made for mass spectrometrists to adopt the practice. Rather than exhaustively cover all possible designs, we have highlighted the three most practical DOE classes available to mass spectrometrists. This review further differentiates itself by providing expert recommendations for experimental setup and defining DOE entirely in the context of three case-studies that highlight the utility of different designs to achieve different goals. A step-by-step tutorial is also provided.
Collapse
Affiliation(s)
- Elizabeth S Hecht
- W. M. Keck FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
| | - Ann L Oberg
- Division of Biomedical Statistics and Informatics, Department of Health Sciences Research, Mayo Clinic, Rochester, MN, 55905, USA
| | - David C Muddiman
- W. M. Keck FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA.
| |
Collapse
|
21
|
González-Ruiz V, Codesido S, Far J, Rudaz S, Schappler J. Evaluation of a new low sheath-flow interface for CE-MS. Electrophoresis 2016; 37:936-46. [DOI: 10.1002/elps.201500523] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2015] [Revised: 01/27/2016] [Accepted: 01/28/2016] [Indexed: 01/27/2023]
Affiliation(s)
- Víctor González-Ruiz
- School of Pharmaceutical Sciences, University of Geneva; University of Lausanne; Geneva 4 Switzerland
| | | | - Johann Far
- Laboratory of Mass Spectrometry, Chemistry Institute; University of Liège; Liège Belgium
- Analis; Suarlee Belgium
| | - Serge Rudaz
- School of Pharmaceutical Sciences, University of Geneva; University of Lausanne; Geneva 4 Switzerland
| | - Julie Schappler
- School of Pharmaceutical Sciences, University of Geneva; University of Lausanne; Geneva 4 Switzerland
| |
Collapse
|
22
|
Gahoual R, Beck A, François YN, Leize-Wagner E. Independent highly sensitive characterization of asparagine deamidation and aspartic acid isomerization by sheathless CZE-ESI-MS/MS. JOURNAL OF MASS SPECTROMETRY : JMS 2016; 51:150-158. [PMID: 26889931 DOI: 10.1002/jms.3735] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2015] [Revised: 11/02/2015] [Accepted: 11/15/2015] [Indexed: 06/05/2023]
Abstract
Amino acids residues are commonly submitted to various physicochemical modifications occurring at physiological pH and temperature. Post-translational modifications (PTMs) require comprehensive characterization because of their major influence on protein structure and involvement in numerous in vivo process or signaling. Mass spectrometry (MS) has gradually become an analytical tool of choice to characterize PTMs; however, some modifications are still challenging because of sample faint modification levels or difficulty to separate an intact peptide from modified counterparts before their transfer to the ionization source. Here, we report the implementation of capillary zone electrophoresis coupled to electrospray ionization tandem mass spectrometry (CZE-ESI-MS/MS) by the intermediate of a sheathless interfacing for independent and highly sensitive characterization of asparagine deamidation (deaN) and aspartic acid isomerization (isoD). CZE selectivity regarding deaN and isoD was studied extensively using different sets of synthetic peptides based on actual tryptic peptides. Results demonstrated CZE ability to separate the unmodified peptide from modified homologous exhibiting deaN, isoD or both independently with a resolution systematically superior to 1.29. Developed CZE-ESI-MS/MS method was applied for the characterization of monoclonal antibodies and complex protein mixture. Conserved CZE selectivity could be demonstrated even for complex samples, and foremost results obtained showed that CZE selectivity is similar regardless of the composition of the peptide. Separation of modified peptides prior to the MS analysis allowed to characterize and estimate modification levels of the sample independently for deaN and isoD even for peptides affected by both modifications and, as a consequence, enables to distinguish the formation of l-aspartic acid or d-aspartic acid generated from deaN. Separation based on peptide modification allowed, as supported by the ESI efficiency provided by CZE-ESI-MS/MS properties, and enabled to characterize and estimate studied PTMs with an unprecedented sensitivity and proved the relevance of implementing an electrophoretic driven separation for MS-based peptide analysis.
Collapse
Affiliation(s)
- Rabah Gahoual
- Laboratoire de Spectrométrie de Masse des Interactions et des Systèmes (LSMIS), UMR 7140 (UdS-CNRS), Université de Strasbourg, Strasbourg, France
- Division of BioAnalytical Chemistry, AIMMS Research Group BioMolecular Analysis, VU University Amsterdam, De Boelelaan 1083, 1081 HV, Amsterdam, The Netherlands
| | - Alain Beck
- Centre d'Immunologie Pierre Fabre, Saint-Julien-en-Genevois, France
| | - Yannis-Nicolas François
- Laboratoire de Spectrométrie de Masse des Interactions et des Systèmes (LSMIS), UMR 7140 (UdS-CNRS), Université de Strasbourg, Strasbourg, France
| | - Emmanuelle Leize-Wagner
- Division of BioAnalytical Chemistry, AIMMS Research Group BioMolecular Analysis, VU University Amsterdam, De Boelelaan 1083, 1081 HV, Amsterdam, The Netherlands
| |
Collapse
|
23
|
Affiliation(s)
- Rachel K Harstad
- University of Minnesota , Department of Chemistry, 207 Pleasant Street South East, Minneapolis, Minnesota 55455, United States
| | - Alexander C Johnson
- University of Minnesota , Department of Chemistry, 207 Pleasant Street South East, Minneapolis, Minnesota 55455, United States
| | - Megan M Weisenberger
- University of Minnesota , Department of Chemistry, 207 Pleasant Street South East, Minneapolis, Minnesota 55455, United States
| | - Michael T Bowser
- University of Minnesota , Department of Chemistry, 207 Pleasant Street South East, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
24
|
Gahoual R, Biacchi M, Chicher J, Kuhn L, Hammann P, Beck A, Leize-Wagner E, François YN. Monoclonal antibodies biosimilarity assessment using transient isotachophoresis capillary zone electrophoresis-tandem mass spectrometry. MAbs 2015; 6:1464-73. [PMID: 25484058 DOI: 10.4161/mabs.36305] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Out of all categories, monoclonal antibody (mAb) therapeutics attract the most interest due to their strong therapeutic potency and specificity. Six of the 10 top-selling drugs are antibody-based therapeutics that will lose patent protection soon. The European Medicines Agency has pioneered the regulatory framework for approval of biosimilar products and approved the first biosimilar antibodies by the end of 2013. As highly complex glycoproteins with a wide range of micro-variants, mAbs require extensive characterization through multiple analytical methods for structure assessment rendering manufacturing control and biosimilarity studies particularly product and time-consuming. Here, capillary zone electrophoresis coupled to mass spectrometry by a sheathless interface (CESI-MS) was used to characterize marketed reference mAbs and their respective biosimilar candidate simultaneously over different facets of their primary structure. CESI-MS/MS data were compared between approved mAbs and their biosimilar candidates to prove/disconfirm biosimilarity regarding recent regulation directives. Using only a single sample injection of 200 fmol, CESI-MS/MS data enabled 100% amino acids (AA) sequence characterization, which allows a difference of even one AA between 2 samples to be distinguished precisely. Simultaneously glycoforms were characterized regarding their structures and position through fragmentation spectra and glycoforms semiquantitative analysis was established, showing the capacity of the developed methodology to detect up to 16 different glycans. Other posttranslational modifications hotspots were characterized while their relative occurrence levels were estimated and compared to biosimilars. These results proved the value of using CESI-MS because the separation selectivity and ionization efficiency provided by the system allowed substantial improvement in the characterization workflow robustness and accuracy. Biosimilarity assessment could be performed routinely with a single injection of each candidate enabling improvements in the biosimilar development pipeline.
Collapse
Affiliation(s)
- Rabah Gahoual
- a Laboratoire de spectrométrie de masse des interactions et des systèmes (LSMIS); CNRS - UMR 7140 , Université de Strasbourg , Strasbourg Cedex , France
| | | | | | | | | | | | | | | |
Collapse
|
25
|
Pontillo C, Filip S, Borràs DM, Mullen W, Vlahou A, Mischak H. CE-MS-based proteomics in biomarker discovery and clinical application. Proteomics Clin Appl 2015; 9:322-34. [DOI: 10.1002/prca.201400115] [Citation(s) in RCA: 64] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2014] [Revised: 11/10/2014] [Accepted: 01/14/2015] [Indexed: 12/19/2022]
Affiliation(s)
- Claudia Pontillo
- Department of R&D; Mosaiques Diagnostics GmbH; Hanover Germany
- Charité-Universitätsmedizin Berlin; Berlin Germany
| | - Szymon Filip
- Charité-Universitätsmedizin Berlin; Berlin Germany
- Biotechnology Division; Biomedical Research Foundation; Academy of Athens; Athens Greece
| | - Daniel M. Borràs
- Department of R&D; ServiceXS; Leiden The Netherlands
- Institut National de la Santé et de la Recherche Médicale (INSERM); Institute of Cardiovascular and Metabolic Disease; Toulouse France
- Université Toulouse III Paul-Sabatier; Toulouse France
| | - William Mullen
- Institute of Cardiovascular and Medical Sciences; University of Glasgow; Glasgow UK
| | - Antonia Vlahou
- Biotechnology Division; Biomedical Research Foundation; Academy of Athens; Athens Greece
- School of Biomedical and Healthcare Sciences; Plymouth University; Plymouth UK
| | - Harald Mischak
- Department of R&D; Mosaiques Diagnostics GmbH; Hanover Germany
- Institute of Cardiovascular and Medical Sciences; University of Glasgow; Glasgow UK
| |
Collapse
|
26
|
Moini M, Rollman CM. Compatibility of highly sulfated cyclodextrin with electrospray ionization at low nanoliter/minute flow rates and its application to capillary electrophoresis/electrospray ionization mass spectrometric analysis of cathinone derivatives and their optical isomers. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2015; 29:304-10. [PMID: 26411628 DOI: 10.1002/rcm.7106] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/10/2014] [Revised: 11/13/2014] [Accepted: 11/24/2014] [Indexed: 05/14/2023]
Abstract
RATIONALE Sodium salts of cyclodextrins are commonly used in capillary electrophoresis/mass spectrometry (CE/MS) analysis of illicit drugs and their optical isomers. To avoid the suppression effect of cyclodextrins under electrospray ionization (ESI), the partial filling technique (PFT) is commonly utilized, which has a limited resolution. Low-flow nano-ESI has been shown to reduce the suppression effect of the salts. To test the compatibility of low-flow ESI with a background electrolyte (BGE) containing sodium salts of cyclodextrin, sheathless narrow capillary CE/MS with flow rates of low nanoliters/minute (nL/min) was applied to the separation and detection of cathinones and their positional and optical isomers for the first time. METHODS Low-flow sheathless CE/MS using a 20-µm-i.d. capillary in conjunction with a porous tip interface was used for the separation of cathinone derivatives and their optical isomers. Highly sulfated γ-cyclodextrin (HS-γ-CD) in conjunction with (+)-18-crown-6-tetracarboxylic acid ((+)-18-C-6-TCA) was used as the BGE and an ion trap mass spectrometer operating in full scan mode was utilized. RESULTS Utilizing low flow rate (~10 nL/min) sheathless CE/MS, the use of the sodium salt of HS-γ-CD as the BGE was compared with the same solution using PFT. The relative and absolute sensitivity of detection of cathinones were about the same, indicating that under low-flow sheathless CE/MS there was no significant suppression due to the existence of HS-γ-CD in the electrospray process. However, enhanced resolution of cathinone derivatives and their positional and optical isomers was observed when the solution of HS-γ-CD was used as the BGE. The enhanced resolution was because of the presence of the HS-γ-CD in the entire capillary during the analysis. The addition of 15 mM (+)-18-C-6-TCA to the BGE containing HS-γ-CD further enhanced the resolution resulting in separation of all cathinones and their positional and optical isomers. CONCLUSIONS A novel CE/MS technique has been introduced that combines low-flow sheathless CE/MS, with HS-γ-CD and 15 mM (+)-18-C-6-TCA as the BGE for separation of cathinone derivatives as well as their positional and optical isomers.
Collapse
Affiliation(s)
- Mehdi Moini
- Department of Forensic Sciences, George Washington University, Washington, DC, USA
| | | |
Collapse
|
27
|
Liu JX, Zhang YW, Yuan F, Chen HX, Zhang XX. Differential detection of Rhizoma coptidis by capillary electrophoresis electrospray ionization mass spectrometry with a nanospray interface. Electrophoresis 2014; 35:3258-63. [PMID: 25143257 DOI: 10.1002/elps.201400334] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2014] [Revised: 08/06/2014] [Accepted: 08/12/2014] [Indexed: 01/07/2023]
Abstract
A lab prototype CE-nanospray-MS platform with a high sensitivity porous sprayer was successfully applied in differential identification of Rhizoma coptidis in this paper. To obtain a stable and reliable nanospray, detailed optimizations about emitter geometry, buffer composition, emitter position, and spray voltage, as well as emitter cleanliness were discussed. Results showed that the reproducibility and sensitivity for separations of alkaloid standards were satisfactory using CE-nanospray-MS, which were also compared to ultra-HPLC (UHPLC)-MS. Their signal responds were at the same order of magnitude (intensities: 0.8 - 1.5 × 10(8) vs. 3.8 - 6.2 × 10(8) ), even though a 2 nL injection for CE was 2500-fold lower than UHPLC (5 μL injection). The absolute LOD results of CE-MS showed a remarkable superiority (18-24 fg), equal to 1000-fold lower than that of UHPLC-MS. Principal component analysis (PCA) of adulterated R. coptidis showed that this protocol had the ability to profile and qualify complex herb medicines, which also created a great potential for evaluation and qualification of rare and valuable Chinese medicines in future.
Collapse
Affiliation(s)
- Jing-Xin Liu
- Beijing National Laboratory for Molecular Sciences (BNLMS), Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Institute of Analytical Chemistry, College of Chemistry, Peking University, Beijing, P. R. China
| | | | | | | | | |
Collapse
|
28
|
Batz NG, Mellors JS, Alarie JP, Ramsey JM. Chemical vapor deposition of aminopropyl silanes in microfluidic channels for highly efficient microchip capillary electrophoresis-electrospray ionization-mass spectrometry. Anal Chem 2014; 86:3493-500. [PMID: 24655020 DOI: 10.1021/ac404106u] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
We describe a chemical vapor deposition (CVD) method for the surface modification of glass microfluidic devices designed to perform electrophoretic separations of cationic species. The microfluidic channel surfaces were modified using aminopropyl silane reagents. Coating homogeneity was inferred by precise measurement of the separation efficiency and electroosmotic mobility for multiple microfluidic devices. Devices coated with (3-aminopropyl)di-isopropylethoxysilane (APDIPES) yielded near diffusion-limited separations and exhibited little change in electroosmotic mobility between pH 2.8 and pH 7.5. We further evaluated the temporal stability of both APDIPES and (3-aminopropyl)triethoxysilane (APTES) coatings when stored for a total of 1 week under vacuum at 4 °C or filled with pH 2.8 background electrolyte at room temperature. Measurements of electroosmotic flow (EOF) and separation efficiency during this time confirmed that both coatings were stable under both conditions. Microfluidic devices with a 23 cm long, serpentine electrophoretic separation channel and integrated nanoelectrospray ionization emitter were CVD coated with APDIPES and used for capillary electrophoresis (CE)-electrospray ionization (ESI)-mass spectrometry (MS) of peptides and proteins. Peptide separations were fast and highly efficient, yielding theoretical plate counts over 600,000 and a peak capacity of 64 in less than 90 s. Intact protein separations using these devices yielded Gaussian peak profiles with separation efficiencies between 100,000 and 400,000 theoretical plates.
Collapse
Affiliation(s)
- Nicholas G Batz
- Department of Chemistry, ‡Department of Biomedical Engineering, and §Carolina Center for Genome Sciences, University of North Carolina , Chapel Hill, North Carolina 27599, United States
| | | | | | | |
Collapse
|
29
|
Medina-Casanellas S, Domínguez-Vega E, Benavente F, Sanz-Nebot V, Somsen GW, de Jong GJ. Low-picomolar analysis of peptides by on-line coupling of fritless solid-phase extraction to sheathless capillary electrophoresis-mass spectrometry. J Chromatogr A 2013; 1328:1-6. [PMID: 24438833 DOI: 10.1016/j.chroma.2013.12.080] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2013] [Revised: 12/09/2013] [Accepted: 12/24/2013] [Indexed: 01/01/2023]
Abstract
A novel fritless solid-phase extraction (SPE) microcartridge was designed for combination with sheathless capillary electrophoresis-mass spectrometry (sheathless CE-MS) employing a prototype porous-tip capillary for nanoelectrospray ionization (nanoESI). The inlet of the separation capillary (30μm inner diameter (id), 150μm outer diameter (od)) was inserted in a 4mm long SPE microcartridge (150μm id, 365μm od) packed with a C18 sorbent of 55-105μm particle size. Performance of the SPE-CE-MS system was evaluated using diluted solutions of the three opioid peptides dynorphin A (1-7) (DynA), endomorphin 1 (End1) and met-enkephalin (Met). Sample volumes of 1.5μL were loaded on the SPE microcartridge and the retained peptides were eluted with 22nL of an acidic methanol/water (60:40, v/v) solution. Using a pressure of 50mbar during separation to speed up the analysis, good peptide resolution was obtained with acceptable plate numbers (between 53,000 and 92,000). Intraday relative standard deviations (% RSD) for peptide migration times and peak areas were below 4% and 9%, respectively. The SPE-CE-MS method showed good linearity in the 0.05-5ngmL(-1) range and limits of detection (LODs) were 10pgmL(-1). However, loading a larger volume of sample (8μL), LODs could be decreased down to 2pgmL(-1) (2.2-3.5pM). This represents an improvement of up to 5000-fold with respect to the LODs achieved by sheathless CE-MS without on-line preconcentration demonstrating the potential of on-line SPE for further enhancing sensitivity.
Collapse
Affiliation(s)
- Silvia Medina-Casanellas
- Department of Analytical Chemistry, University of Barcelona, Diagonal 645, 08028 Barcelona, Spain; Biomolecular Analysis, Utrecht University, P.O. Box 80082, 3508 TB Utrecht, The Netherlands
| | - Elena Domínguez-Vega
- Biomolecular Analysis, Utrecht University, P.O. Box 80082, 3508 TB Utrecht, The Netherlands
| | - Fernando Benavente
- Department of Analytical Chemistry, University of Barcelona, Diagonal 645, 08028 Barcelona, Spain.
| | - Victoria Sanz-Nebot
- Department of Analytical Chemistry, University of Barcelona, Diagonal 645, 08028 Barcelona, Spain
| | - Govert W Somsen
- Biomolecular Analysis, Utrecht University, P.O. Box 80082, 3508 TB Utrecht, The Netherlands; AIMMS Division of BioAnalytical Chemistry, VU University, De Boelelaan 1083, 1081 HV Amsterdam, The Netherlands
| | - Gerhardus J de Jong
- Biomolecular Analysis, Utrecht University, P.O. Box 80082, 3508 TB Utrecht, The Netherlands
| |
Collapse
|
30
|
Zhong X, Zhang Z, Jiang S, Li L. Recent advances in coupling capillary electrophoresis-based separation techniques to ESI and MALDI-MS. Electrophoresis 2013; 35:1214-25. [PMID: 24170529 DOI: 10.1002/elps.201300451] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2013] [Revised: 10/14/2013] [Accepted: 10/15/2013] [Indexed: 01/13/2023]
Abstract
Coupling CE-based separation techniques to MS creates a powerful platform for analysis of a wide range of biomolecules from complex samples because it combines the high separation efficiency of CE and the sensitivity and selectivity of MS detection. ESI and MALDI, as the most common soft ionization techniques employed for CE and MS coupling, offer distinct advantages for biomolecular characterization. This review is focused primarily on technological advances in combining CE and chip-based CE with ESI and MALDI-MS detection in the past five years. Selected applications in the analyses of metabolites, peptides, and proteins with recently developed CE-MS platforms are also highlighted.
Collapse
Affiliation(s)
- Xuefei Zhong
- School of Pharmacy, University of Wisconsin, Madison, WI, USA
| | | | | | | |
Collapse
|
31
|
Bonvin G, Schappler J, Rudaz S. Non-aqueous capillary electrophoresis for the analysis of acidic compounds using negative electrospray ionization mass spectrometry. J Chromatogr A 2013; 1323:163-73. [PMID: 24315358 DOI: 10.1016/j.chroma.2013.11.011] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2013] [Revised: 10/30/2013] [Accepted: 11/01/2013] [Indexed: 01/09/2023]
Abstract
Non-aqueous capillary electrophoresis (NACE) is an attractive CE mode, in which water solvent of the background electrolyte (BGE) is replaced by organic solvent or by a mixture of organic solvents. This substitution alters several parameters, such as the pKa, permittivity, viscosity, zeta potential, and conductivity, resulting in a modification of CE separation performance (i.e., selectivity and/or efficiency). In addition, the use of NACE is particularly well adapted to ESI-MS due to the high volatility of solvents and the low currents that are generated. Organic solvents reduce the number of side electrochemical reactions at the ESI tip, thereby allowing the stabilization of the ESI current and a decrease in background noise. All these features make NACE an interesting alternative to the aqueous capillary zone electrophoresis (CZE) mode, especially in combination with mass spectrometry (MS) detection. The aim of this work was to evaluate the use of NACE coupled to negative ESI-MS for the analysis of acidic compounds with two available CE-MS interfaces (sheath liquid and sheathless). First, NACE was compared to aqueous CZE for the analysis of several pharmaceutical acidic compounds (non-steroidal anti-inflammatory drugs, NSAIDs). Then, the separation performance and the sensitivity achieved by both interfaces were evaluated, as were the impact of the BGE and the sample composition. Finally, analyses of glucuronides in urine samples subjected to a minimal sample pre-treatment ("dilute-and-shoot") were performed by NACE-ESI-MS, and the matrix effect was evaluated. A 20- to 100-fold improvement in sensitivity was achieved using the NACE mode in combination with the sheathless interface and no matrix effect was observed regardless of the interfaces.
Collapse
Affiliation(s)
- Grégoire Bonvin
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Bd d'Yvoy 20, 1211 Geneva 4, Switzerland
| | - Julie Schappler
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Bd d'Yvoy 20, 1211 Geneva 4, Switzerland
| | - Serge Rudaz
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Bd d'Yvoy 20, 1211 Geneva 4, Switzerland.
| |
Collapse
|
32
|
Clinical applications of capillary electrophoresis coupled to mass spectrometry in biomarker discovery: Focus on bladder cancer. Proteomics Clin Appl 2013; 7:779-93. [DOI: 10.1002/prca.201300038] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
33
|
Stalmach A, Albalat A, Mullen W, Mischak H. Recent advances in capillary electrophoresis coupled to mass spectrometry for clinical proteomic applications. Electrophoresis 2013; 34:1452-64. [DOI: 10.1002/elps.201200708] [Citation(s) in RCA: 98] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2012] [Revised: 02/07/2013] [Accepted: 02/14/2013] [Indexed: 12/14/2022]
Affiliation(s)
- Angelique Stalmach
- Department of Proteomics and Systems Medicine; BHF Glasgow Cardiovascular Research Centre; Institute of Cardiovascular and Medical Sciences; College of Medical Veterinary and Life Sciences; University of Glasgow; Glasgow; UK
| | - Amaya Albalat
- Department of Proteomics and Systems Medicine; BHF Glasgow Cardiovascular Research Centre; Institute of Cardiovascular and Medical Sciences; College of Medical Veterinary and Life Sciences; University of Glasgow; Glasgow; UK
| | - William Mullen
- Department of Proteomics and Systems Medicine; BHF Glasgow Cardiovascular Research Centre; Institute of Cardiovascular and Medical Sciences; College of Medical Veterinary and Life Sciences; University of Glasgow; Glasgow; UK
| | | |
Collapse
|
34
|
Haselberg R, de Jong GJ, Somsen GW. Low-Flow Sheathless Capillary Electrophoresis–Mass Spectrometry for Sensitive Glycoform Profiling of Intact Pharmaceutical Proteins. Anal Chem 2013; 85:2289-96. [DOI: 10.1021/ac303158f] [Citation(s) in RCA: 114] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Affiliation(s)
- Rob Haselberg
- Biomolecular Analysis, Utrecht University, Universiteitsweg 99, 3584 CG Utrecht, The Netherlands
| | - Gerhardus J. de Jong
- Biomolecular Analysis, Utrecht University, Universiteitsweg 99, 3584 CG Utrecht, The Netherlands
| | - Govert W. Somsen
- Biomolecular Analysis, Utrecht University, Universiteitsweg 99, 3584 CG Utrecht, The Netherlands
| |
Collapse
|
35
|
Klepárník K. Recent advances in the combination of capillary electrophoresis with mass spectrometry: From element to single-cell analysis. Electrophoresis 2012; 34:70-85. [DOI: 10.1002/elps.201200488] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2012] [Revised: 10/08/2012] [Accepted: 10/08/2012] [Indexed: 11/11/2022]
Affiliation(s)
- Karel Klepárník
- Institute of Analytical Chemistry; Academy of Sciences of the Czech Republic; Brno; Czech Republic
| |
Collapse
|
36
|
Haselberg R, de Jong GJ, Somsen GW. CE-MS for the analysis of intact proteins 2010-2012. Electrophoresis 2012; 34:99-112. [DOI: 10.1002/elps.201200439] [Citation(s) in RCA: 84] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2012] [Revised: 10/08/2012] [Accepted: 10/09/2012] [Indexed: 12/18/2022]
Affiliation(s)
- Rob Haselberg
- Biomolecular Analysis; Utrecht University; CG Utrecht; The Netherlands
| | | | - Govert W. Somsen
- Biomolecular Analysis; Utrecht University; CG Utrecht; The Netherlands
| |
Collapse
|
37
|
Bonvin G, Schappler J, Rudaz S. Capillary electrophoresis–electrospray ionization-mass spectrometry interfaces: Fundamental concepts and technical developments. J Chromatogr A 2012; 1267:17-31. [DOI: 10.1016/j.chroma.2012.07.019] [Citation(s) in RCA: 66] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2012] [Revised: 07/04/2012] [Accepted: 07/06/2012] [Indexed: 01/24/2023]
|
38
|
Mark LP, Gill MC, Mahut M, Derrick PJ. Dual nano-electrospray for probing solution interactions and fast reactions of complex biomolecules. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2012; 18:439-46. [PMID: 23221113 DOI: 10.1255/ejms.1198] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
A novel nano-electrospray emitter has been developed containing two separated channels running throughout the length of the emitter. The emitters have been fabricated from "theta-shaped" borosilicate capillaries. Loading of different solutions into the two different channels opens up the possibility to study short timescale interactions within a Taylor cone common to both channels. The common Taylor cone constitutes an extremely small "mixing volume" of the order of femtolitres. The products of electrospray from the dual-channel emitters have been analysed by Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry. Results are presented for interactions of vancomycin with diacetyl-L-lysyl-D-alanyl- D-alanine and interactions of vancomycin with deuterated vancomycin. On the basis of these results, it is concluded that, during electrospray, specific non-covalent adducts have been formed and that there have been exchange reactions involving making and breaking of covalent bonds.
Collapse
Affiliation(s)
- Lewis P Mark
- Department of Chemistry, University of Warwick, Coventry, UK
| | | | | | | |
Collapse
|