1
|
Rahman MA, Pal RK, Islam N, Freeman R, Berthiaume F, Mazzeo A, Ashraf A. A Facile Graphene Conductive Polymer Paper Based Biosensor for Dopamine, TNF-α, and IL-6 Detection. SENSORS (BASEL, SWITZERLAND) 2023; 23:8115. [PMID: 37836943 PMCID: PMC10575219 DOI: 10.3390/s23198115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 09/20/2023] [Accepted: 09/22/2023] [Indexed: 10/15/2023]
Abstract
Paper-based biosensors are a potential paradigm of sensitivity achieved via microporous spreading/microfluidics, simplicity, and affordability. In this paper, we develop decorated paper with graphene and conductive polymer (herein referred to as graphene conductive polymer paper-based sensor or GCPPS) for sensitive detection of biomolecules. Planetary mixing resulted in uniformly dispersed graphene and conductive polymer ink, which was applied to laser-cut Whatman filter paper substrates. Scanning electron microscopy and Raman spectroscopy showed strong attachment of conductive polymer-functionalized graphene to cellulose fibers. The GCPPS detected dopamine and cytokines, such as tumor necrosis factor-alpha (TNF-α), and interleukin 6 (IL-6) in the ranges of 12.5-400 µM, 0.005-50 ng/mL, and 2 pg/mL-2 µg/mL, respectively, using a minute sample volume of 2 µL. The electrodes showed lower detection limits (LODs) of 3.4 µM, 5.97 pg/mL, and 9.55 pg/mL for dopamine, TNF-α, and IL-6 respectively, which are promising for rapid and easy analysis for biomarkers detection. Additionally, these paper-based biosensors were highly selective (no serpin A1 detection with IL-6 antibody) and were able to detect IL-6 antigen in human serum with high sensitivity and hence, the portable, adaptable, point-of-care, quick, minute sample requirement offered by our fabricated biosensor is advantageous to healthcare applications.
Collapse
Affiliation(s)
- Md Ashiqur Rahman
- Department of Mechanical Engineering, Purdue University, West Lafayette, IN 47906, USA;
| | - Ramendra Kishor Pal
- Hyderabad Campus, Birla Institute of Technology and Science Pilani, Hyderabad 500078, Telangana, India;
| | - Nazmul Islam
- Department of Electrical and Computer Engineering, University of Texas Rio Grande Valley, Edinburg, TX 78539, USA;
| | - Robert Freeman
- Department of Mechanical Engineering, University of Texas Rio Grande Valley, Edinburg, TX 78539, USA;
| | - Francois Berthiaume
- Department of Biomedical Engineering, Rutgers University, Piscataway, NJ 08854, USA;
| | - Aaron Mazzeo
- Department of Mechanical & Aerospace Engineering, Rutgers University, Piscataway, NJ 08854, USA
| | - Ali Ashraf
- Department of Mechanical Engineering, University of Texas Rio Grande Valley, Edinburg, TX 78539, USA;
| |
Collapse
|
2
|
Hou F, Sun S, Abdullah SW, Tang Y, Li X, Guo H. The application of nanoparticles in point-of-care testing (POCT) immunoassays. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:2154-2180. [PMID: 37114768 DOI: 10.1039/d3ay00182b] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
The Covid-19 pandemic has led to greater recognition of the importance of the fast and timely detection of pathogens. Recent advances in point-of-care testing (POCT) technology have shown promising results for rapid diagnosis. Immunoassays are among the most extensive POCT assays, in which specific labels are used to indicate and amplify the immune signal. Nanoparticles (NPs) are above the rest because of their versatile properties. Much work has been devoted to NPs to find more efficient immunoassays. Herein, we comprehensively describe NP-based immunoassays with a focus on particle species and their specific applications. This review describes immunoassays along with key concepts surrounding their preparation and bioconjugation to show their defining role in immunosensors. The specific mechanisms, microfluidic immunoassays, electrochemical immunoassays (ELCAs), immunochromatographic assays (ICAs), enzyme-linked immunosorbent assays (ELISA), and microarrays are covered herein. For each mechanism, a working explanation of the appropriate background theory and formalism is articulated before examining the biosensing and related point-of-care (POC) utility. Given their maturity, some specific applications using different nanomaterials are discussed in more detail. Finally, we outline future challenges and perspectives to give a brief guideline for the development of appropriate platforms.
Collapse
Affiliation(s)
- Fengping Hou
- State Key Laboratory of Veterinary Etiological Biology, OIE/China National Foot-and-Mouth Disease Reference Laboratory, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Xujiaping 1, Lanzhou 730046, Gansu, P. R. China.
- Lanzhou Institute of Biological Products Co., Ltd (LIBP), Subsidiary Company of China National Biotec Group Company Limited (CNBG), 730046 Lanzhou, China.
| | - Shiqi Sun
- State Key Laboratory of Veterinary Etiological Biology, OIE/China National Foot-and-Mouth Disease Reference Laboratory, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Xujiaping 1, Lanzhou 730046, Gansu, P. R. China.
| | - Sahibzada Waheed Abdullah
- State Key Laboratory of Veterinary Etiological Biology, OIE/China National Foot-and-Mouth Disease Reference Laboratory, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Xujiaping 1, Lanzhou 730046, Gansu, P. R. China.
| | - Yu Tang
- State Key Laboratory of Applied Organic Chemistry, Key Laboratory of Nonferrous Metal Chemistry and Resources Utilization of Gansu Province, College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou 730000, Gansu, P. R. China
| | - Xiongxiong Li
- Lanzhou Institute of Biological Products Co., Ltd (LIBP), Subsidiary Company of China National Biotec Group Company Limited (CNBG), 730046 Lanzhou, China.
| | - Huichen Guo
- State Key Laboratory of Veterinary Etiological Biology, OIE/China National Foot-and-Mouth Disease Reference Laboratory, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Xujiaping 1, Lanzhou 730046, Gansu, P. R. China.
- State Key Laboratory for Animal Disease Control and Prevention, College of Veterinary Medicine, Lanzhou University, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Lanzhou 730000, P. R. China
| |
Collapse
|
3
|
Aghababaie M, Foroushani ES, Changani Z, Gunani Z, Mobarakeh MS, Hadady H, Khedri M, Maleki R, Asadnia M, Razmjou A. Recent Advances In the development of enzymatic paper-based microfluidic biosensors. Biosens Bioelectron 2023; 226:115131. [PMID: 36804663 DOI: 10.1016/j.bios.2023.115131] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2022] [Revised: 02/03/2023] [Accepted: 02/04/2023] [Indexed: 02/09/2023]
Abstract
Using microfluidic paper-based analytical devices has attracted considerable attention in recent years. This is mainly due to their low cost, availability, portability, simple design, high selectivity, and sensitivity. Owing to their specific substrates and catalytic functions, enzymes are the most commonly used bioactive agents in μPADs. Enzymatic μPADs are various in design, fabrication, and detection methods. This paper provides a comprehensive review of the development of enzymatic μPADs by considering the methods of detection and fabrication. Particularly, techniques for mass production of these enzymatic μPADs for use in different fields such as medicine, environment, agriculture, and food industries are critically discussed. This paper aims to provide a critical review of μPADs and discuss different fabrication methods as the central parts of the μPADs production categorized into printable and non-printable methods. In addition, state-of-the-art technologies such as fully printed enzymatic μPADs for rapid, low-cost, and mass production and improvement have been considered.
Collapse
Affiliation(s)
- Marzieh Aghababaie
- Auckland Bioengineering Institute, University of Auckland, Auckland, 1010, New Zealand; Department of Biotechnology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, Iran.
| | - Elnaz Sarrami Foroushani
- Department of Biotechnology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, Iran.
| | - Zinat Changani
- Department of Biotechnology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, Iran; School of Engineering, Macquarie University, Sydney, New South Wales, 2109, Australia.
| | - Zahra Gunani
- Division of Pharmaceutical Biosciences, Faculty of Pharmacy, University of Helsinki, 00790, FInland.
| | - Mahsa Salehi Mobarakeh
- Department of Biotechnology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, Iran; Department of Mechanical and Aerospace Engineering, Carleton University, Colonel by Drive, Ottawa, ON, K1S 5B6, Canada.
| | - Hanieh Hadady
- Cell Science Research Centre, Royan Institute of Biotechnology, Isfahan, Iran.
| | - Mohammad Khedri
- Department of Chemical Engineering, Amirkabir University of Technology, 424 Hafez Avenue, Tehran, Iran.
| | - Reza Maleki
- Department of Chemical Engineering, Shiraz University, Shiraz, Iran
| | - Mohsen Asadnia
- School of Engineering, Macquarie University, Sydney, New South Wales, 2109, Australia
| | - Amir Razmjou
- Mineral Recovery Research Center (MRRC), School of Engineering, Edith Cowan University, Joondalup, Perth, WA, 6027, Australia; UNESCO Centre for Membrane Science and Technology, School of Chemical Engineering, University of New South Wales, Sydney, NSW, 2052, Australia.
| |
Collapse
|
4
|
Holman JB, Shi Z, Fadahunsi AA, Li C, Ding W. Advances on microfluidic paper-based electroanalytical devices. Biotechnol Adv 2023; 63:108093. [PMID: 36603801 DOI: 10.1016/j.biotechadv.2022.108093] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Revised: 12/30/2022] [Accepted: 12/30/2022] [Indexed: 01/03/2023]
Abstract
Since the inception of the first electrochemical devices on paper substrates, many different reports of microfluidic paper-based electroanalytical devices (μPEDs), innovative hydrophobic barriers and electrode fabrication processes have allowed the incorporation of diverse materials, resulting in different applications and a boost in performance. These advancements have led to the creation of paper-based devices with comparable performance to many standard conventional devices, with the added benefits of pumpless fluidic transport, component separation and reagent storage that can be exploited to automate and handle sample preprocessing. Herein, we review μPEDs, summarize the characteristics and functionalities of μPEDs, such as separation, fluid flow control and storage, and outline the conventional and emerging fabrication and modification approaches for μPEDs. We also examine the recent application of μPEDs in biomedicine, the environment, and food and water safety, as well as some limitations and challenges that must be addressed.
Collapse
Affiliation(s)
- Joseph Benjamin Holman
- School of Information Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Zhengdi Shi
- School of Information Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Adeola A Fadahunsi
- School of Information Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Chengpan Li
- School of Information Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China.
| | - Weiping Ding
- Department of Oncology, the First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui 230001, China.
| |
Collapse
|
5
|
Tavakoli H, Mohammadi S, Li X, Fu G, Li X. Microfluidic platforms integrated with nano-sensors for point-of-care bioanalysis. Trends Analyt Chem 2022; 157:116806. [PMID: 37929277 PMCID: PMC10621318 DOI: 10.1016/j.trac.2022.116806] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Microfluidic technology provides a portable, cost-effective, and versatile tool for point-of-care (POC) bioanalysis because of its associated advantages such as fast analysis, low volumes of reagent consumption, and high portability. Along with microfluidics, the application of nanomaterials in biosensing has attracted lots of attention due to their unique physical and chemical properties for enhanced signal modulation such as signal amplification and signal transduction for POC bioanalysis. Hence, an enormous number of microfluidic devices integrated with nano-sensors have been developed for POC bioanalysis targeting low-resource settings. Herein, we review recent advances in POC bioanalysis on nano-sensor-based microfluidic platforms. We first briefly summarized the different types of cost-effective microfluidic platforms, followed by a concise introduction to nanomaterial-based biosensors. Then, we highlighted the application of microfluidic platforms integrated with nano-sensors for POC bioanalysis. Finally, we discussed the current limitations and perspective trends of the nano-sensor-based microfluidic platforms for POC bioanalysis.
Collapse
Affiliation(s)
- Hamed Tavakoli
- Department of Chemistry and Biochemistry, University of Texas at El Paso, El Paso, TX, 79968, USA
| | - Samayeh Mohammadi
- Department of Chemistry and Biochemistry, University of Texas at El Paso, El Paso, TX, 79968, USA
| | - Xiaochun Li
- College of Biomedical Engineering, Taiyuan University of Technology, Shanxi, 030606, China
| | - Guanglei Fu
- School of Pharmacy, Key Laboratory of Molecular Pharmacology and Drug Evaluation, Ministry of Education, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Yantai University, Yantai, Shandong, 264005, China
| | - XiuJun Li
- Department of Chemistry and Biochemistry, University of Texas at El Paso, El Paso, TX, 79968, USA
- Border Biomedical Research Center, Forensic Science, & Environmental Science and Engineering, University of Texas at El Paso, El Paso, 79968, USA
| |
Collapse
|
6
|
Kuswandi B, Hidayat MA, Noviana E. Paper-Based Electrochemical Biosensors for Food Safety Analysis. BIOSENSORS 2022; 12:1088. [PMID: 36551055 PMCID: PMC9775995 DOI: 10.3390/bios12121088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 11/15/2022] [Accepted: 11/21/2022] [Indexed: 06/17/2023]
Abstract
Nowadays, foodborne pathogens and other food contaminants are among the major contributors to human illnesses and even deaths worldwide. There is a growing need for improvements in food safety globally. However, it is a challenge to detect and identify these harmful analytes in a rapid, sensitive, portable, and user-friendly manner. Recently, researchers have paid attention to the development of paper-based electrochemical biosensors due to their features and promising potential for food safety analysis. The use of paper in electrochemical biosensors offers several advantages such as device miniaturization, low sample consumption, inexpensive mass production, capillary force-driven fluid flow, and capability to store reagents within the pores of the paper substrate. Various paper-based electrochemical biosensors have been developed to enable the detection of foodborne pathogens and other contaminants that pose health hazards to humans. In this review, we discussed several aspects of the biosensors including different device designs (e.g., 2D and 3D devices), fabrication techniques, and electrode modification approaches that are often optimized to generate measurable signals for sensitive detection of analytes. The utilization of different nanomaterials for the modification of electrode surface to improve the detection of analytes via enzyme-, antigen/antibody-, DNA-, aptamer-, and cell-based bioassays is also described. Next, we discussed the current applications of the sensors to detect food contaminants such as foodborne pathogens, pesticides, veterinary drug residues, allergens, and heavy metals. Most of the electrochemical paper analytical devices (e-PADs) reviewed are small and portable, and therefore are suitable for field applications. Lastly, e-PADs are an excellent platform for food safety analysis owing to their user-friendliness, low cost, sensitivity, and a high potential for customization to meet certain analytical needs.
Collapse
Affiliation(s)
- Bambang Kuswandi
- Chemo and Biosensors Group, Faculty of Farmasi, University of Jember, Jember 68121, Indonesia
| | - Mochammad Amrun Hidayat
- Chemo and Biosensors Group, Faculty of Farmasi, University of Jember, Jember 68121, Indonesia
| | - Eka Noviana
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Universitas Gadjah Mada, Yogyakarta 55281, Indonesia
| |
Collapse
|
7
|
Screen-printed electrochemical sensors for environmental monitoring of heavy metal ion detection. REV CHEM ENG 2022. [DOI: 10.1515/revce-2022-0002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Abstract
Heavy metal ions (HMIs) are known to cause severe damages to the human body and ecological environment. And considering the current alarming situation, it is crucial to develop a rapid, sensitive, robust, economical and convenient method for their detection. Screen printed electrochemical technology contributes greatly to this task, and has achieved global attention. It enabled the mass transmission rate and demonstrated ability to control the chemical nature of the measure media. Besides, the technique offers advantages like linear output, quick response, high selectivity, sensitivity and stability along with low power requirement and high signal-to-noise ratio. Recently, the performance of SPEs has been improved employing the most effective and promising method of the incorporation of different nanomaterials into SPEs. Especially, in electrochemical sensors, the incorporation of nanomaterials has gained extensive attention for HMIs detection as it exhibits outstanding features like broad electrochemical window, large surface area, high conductivity, selectivity and stability. The present review focuses on the recent progress in the field of screen-printed electrochemical sensors for HMIs detection using nanomaterials. Different fabrication methods of SPEs and their utilization for real sample analysis of HMIs using various nanomaterials have been extensively discussed. Additionally, advancement made in this field is also discussed taking help of the recent literature.
Collapse
|
8
|
Dahake RV, Bansiwal A. Disposable Sensors for Heavy Metals Detection: A Review of Carbon and Non‐Noble Metal‐Based Receptors. ChemistrySelect 2022. [DOI: 10.1002/slct.202202824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Rashmi V. Dahake
- CSIR-National Environmental Engineering Research Institute(NEERI) Nagpur
- Academy of Scientific and Innovative Research (AcSIR) Ghaziabad Uttar Pradesh
| | - Amit Bansiwal
- CSIR-National Environmental Engineering Research Institute(NEERI) Nagpur
| |
Collapse
|
9
|
Loop-Mediated Isothermal Amplification-Based Microfluidic Platforms for the Detection of Viral Infections. Curr Infect Dis Rep 2022; 24:205-215. [PMID: 36341307 PMCID: PMC9628606 DOI: 10.1007/s11908-022-00790-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/15/2022] [Indexed: 11/09/2022]
Abstract
Purpose of Review Easy-to-use, fast, and accurate virus detection method is essential for patient management and epidemic surveillance, especially during severe pandemics. Loop-mediated isothermal amplification (LAMP) on a microfluidic platform is suitable for detecting infectious viruses, regardless of the availability of medical resources. The purpose of this review is to introduce LAMP-based microfluidic devices for virus detection, including their detection principles, methods, and application. Recent Findings Facing the uncontrolled spread of viruses, the large-scale deployment of LAMP-based microfluidic platforms at the grassroots level can help expand the coverage of nucleic acid testing and shorten the time to obtain test reports. Microfluidic chip technology is highly integrated and miniaturized, enabling precise fluid control for effective virus detection. Performing LAMP on miniaturized systems can reduce analysis time, reagent consumption and risk of sample contamination, and improve analytical performance. Summary Compared to traditional benchtop protocols, LAMP-based microfluidic devices reduce the testing time, reagent consumption, and the risk of sample contamination. In addition to simultaneous detection of multiple target genes by special channel design, microfluidic chips can also integrate digital LAMP to achieve absolute quantification of target genes.
Collapse
|
10
|
Ning Q, Zheng W, Xu H, Zhu A, Li T, Cheng Y, Feng S, Wang L, Cui D, Wang K. Rapid segmentation and sensitive analysis of CRP with paper-based microfluidic device using machine learning. Anal Bioanal Chem 2022; 414:3959-3970. [PMID: 35352162 DOI: 10.1007/s00216-022-04039-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 03/19/2022] [Accepted: 03/23/2022] [Indexed: 11/01/2022]
Abstract
Microfluidic paper-based analytical devices (μPADs) have been widely used in point-of-care testing owing to their simple operation, low volume of the sample required, and the lack of the need for an external force. To obtain accurate semi-quantitative or quantitative results, μPADs need to respond to the challenges posed by differences in reaction conditions. In this paper, multi-layer μPADs are fabricated by the imprinting method for the colorimetric detection of C-reactive protein (CRP). Different lighting conditions and shooting angles of scenes are simulated in image acquisition, and the detection-related performance of μPADs is improved by using a machine learning algorithm. The You Only Look Once (YOLO) model is used to identify the areas of reaction in μPADs. This model can observe an image only once to predict the objects present in it and their locations. The YOLO model trained in this study was able to identify all the reaction areas quickly without incurring any error. These reaction areas were categorized by classification algorithms to determine the risk level of CRP concentration. Multi-layer perceptron, convolutional neural network, and residual network algorithms were used for the classification tasks, where the latter yielded the highest accuracy of 96%. It has a promising application prospect in fast recognition and analysis of μPADs.
Collapse
Affiliation(s)
- Qihong Ning
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Wei Zheng
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Hao Xu
- School of Naval Architecture, Ocean & Civil Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Armando Zhu
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Tangan Li
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Yuemeng Cheng
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Shaoqing Feng
- Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China
| | - Li Wang
- School of Electrical Engineering, Henan University of Technology, Zhengzhou, 450007, Henan, China
| | - Daxiang Cui
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Kan Wang
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai Jiao Tong University, Shanghai, 200240, China.
| |
Collapse
|
11
|
Yang L, Zhang Z, Wang X. A Microfluidic PET-Based Electrochemical Glucose Sensor. MICROMACHINES 2022; 13:mi13040552. [PMID: 35457854 PMCID: PMC9031515 DOI: 10.3390/mi13040552] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 03/28/2022] [Accepted: 03/28/2022] [Indexed: 01/15/2023]
Abstract
Paper-based microfluidic sensors have gained increased attention in the field of analytical assays in recent years due to their self-driven nature, ease of preparation, high integration, low reagent consumption, and low cost. However, paper-based microfluidic sensors still have many deficiencies when it comes to the detection of some specific detectors such as blood glucose. For example, the processing procedure for microfluidic channels is tedious, the sensor electrodes are easily damaged by bending, and they can only be used as disposable products. To solve the above problems, a PET-based microfluidic sensor was proposed in this paper, the performance of which was tested with glucose as the target detector. The experimental results showed that the analytical performance of this sensor is comparable to that of existing commercial glucose meters. This work provides implications for the substrate selection of microfluidic chips for some biochemical analyses.
Collapse
Affiliation(s)
- Linda Yang
- College of Mechanical and Aerospace Engineering, Jilin University, Changchun 130022, China; (L.Y.); (Z.Z.)
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun 130022, China
| | - Zheng Zhang
- College of Mechanical and Aerospace Engineering, Jilin University, Changchun 130022, China; (L.Y.); (Z.Z.)
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun 130022, China
| | - Xin Wang
- College of Mechanical and Aerospace Engineering, Jilin University, Changchun 130022, China; (L.Y.); (Z.Z.)
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun 130022, China
- Correspondence:
| |
Collapse
|
12
|
Zhang H, Li X, Zhu Q, Wang Z. The recent development of nanomaterials enhanced paper-based electrochemical analytical devices. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116140] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
13
|
Khan MS, Shadman SA, Khandaker MMR. Advances and current trend of bioactive papers and paper diagnostics for health and biotechnological applications. Curr Opin Chem Eng 2022. [DOI: 10.1016/j.coche.2021.100733] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
14
|
Verma N, Prajapati P, Singh V, Pandya A. An introduction to microfluidics and their applications. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2022; 186:1-14. [PMID: 35033280 DOI: 10.1016/bs.pmbts.2021.07.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
In the past decade, microfluidics and lab-on-chip are rapidly growing area. It has been used for number of biology to biotechnology and medicine applications. It has the potential to reduce cost of reagent and time of experiment. It has been used integrated with automation for extraction and detection of protein, nucleic acids, enzymes, metabolites and delivery of drug to target location. It has been used for drug discovery, high throughput screening of potent drug and used for delivery. Paper based microfluidics was used for point-of-care diagnosis for accurate treatment of diseases. In this chapter, we highlight advances of microfluidics devices for number of biological and translational science applications.
Collapse
Affiliation(s)
- Nidhi Verma
- Department of Engineering and Physical Sciences, Institute of Advanced Research, Gandhinagar, Gujarat, India
| | - Parth Prajapati
- Department of Engineering and Physical Sciences, Institute of Advanced Research, Gandhinagar, Gujarat, India
| | - Vijai Singh
- Department of Biosciences, School of Science, Indrashil University, Rajpur, Mehsana, Gujarat, India
| | - Alok Pandya
- Department of Engineering and Physical Sciences, Institute of Advanced Research, Gandhinagar, Gujarat, India.
| |
Collapse
|
15
|
Mettakoonpitak J, Junkong P, Saenonphut A, Kwamman T, Siripinyanond A, Henry CS. An electrochemical paper-based analytical sensor for one-step latex protein detection. Analyst 2022; 147:932-939. [DOI: 10.1039/d1an02067f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A proposed simple electrochemical paper-based analytical sensor offered one-step latex protein detection by measuring remaining copper after online protein complexation
Collapse
Affiliation(s)
- Jaruwan Mettakoonpitak
- Department of Chemistry, Faculty of Science and Technology, Rambhai Barni Rajabhat University, Chantaburi 22000, Thailand
| | - Preeyanuch Junkong
- Department of Chemistry, Faculty of Science, Mahidol University, Ratchathewi, Bangkok 10400, Thailand
| | - Aphiwan Saenonphut
- Department of Chemistry, Faculty of Science and Technology, Rambhai Barni Rajabhat University, Chantaburi 22000, Thailand
| | - Tanagorn Kwamman
- Thailand Institute of Nuclear Technology (Public Organization), Nakhon Nayok 26120, Thailand
| | - Atitaya Siripinyanond
- Department of Chemistry and Center for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama VI Road, Bangkok 10400, Thailand
| | - Charles S. Henry
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA
| |
Collapse
|
16
|
Hasandka A, Singh AR, Prabhu A, Singhal HR, Nandagopal MSG, Mani NK. Paper and thread as media for the frugal detection of urinary tract infections (UTIs). Anal Bioanal Chem 2022; 414:847-865. [PMID: 34668042 PMCID: PMC8724062 DOI: 10.1007/s00216-021-03671-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 09/02/2021] [Accepted: 09/15/2021] [Indexed: 12/22/2022]
Abstract
Urinary tract infections (UTIs) make up a significant proportion of the global burden of disease in vulnerable groups and tend to substantially impair the quality of life of those affected, making timely detection of UTIs a priority for public health. However, economic and societal barriers drastically reduce accessibility of traditional lab-based testing methods for critical patient groups in low-resource areas, negatively affecting their overall healthcare outcomes. As a result, cellulose-based materials such as paper and thread have garnered significant interest among researchers as substrates for so-called frugal analytical devices which leverage the material's portability and adaptability for facile and reproducible diagnoses of UTIs. Although the field may be only in its infancy, strategies aimed at commercial penetration can appreciably increase access to more healthcare options for at-risk people. In this review, we catalogue recent advances in devices that use cellulose-based materials as the primary housing or medium for UTI detection and chart out trends in the field. We also explore different modalities employed for detection, with particular emphasis on their ability to be ported onto discreet casings such as sanitary products.
Collapse
Affiliation(s)
- Amrutha Hasandka
- Microfluidics, Sensors and Diagnostics Laboratory (μSenD), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Ankita Ramchandran Singh
- Microfluidics, Sensors and Diagnostics Laboratory (μSenD), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Anusha Prabhu
- Microfluidics, Sensors and Diagnostics Laboratory (μSenD), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Hardik Ramesh Singhal
- Department of Chemical Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - M S Giri Nandagopal
- Department of Mechanical Engineering, Indian Institute of Technology, Kharagpur, Kharagpur, 721302, India
| | - Naresh Kumar Mani
- Microfluidics, Sensors and Diagnostics Laboratory (μSenD), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
| |
Collapse
|
17
|
Beardsley CA, Fuller KZ, Reilly TH, Henry CS. Method for analysis of environmental lead contamination in soils. Analyst 2021; 146:7520-7527. [PMID: 34806095 DOI: 10.1039/d1an01744f] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A method for lead (Pb) detection in soil is presented. Pb is a dangerous environmental pollutant that is present in soils, posing a health risk to millions of people worldwide, and regular monitoring of Pb contamination in soils is essential to public health. Many sensitive methods for detection of heavy metals in solid matrices exist, but they cannot be performed on-site because they are costly (>$30 per sample), require trained personnel, and many classical sample preparation methods are not safe to bring into the field. We describe an alternative process, combining a safer sample preparation method with electrochemical analysis. The process requires minimal training, making it an attractive overall method for regular environmental screening of Pb in soils. Extract obtained from the soil is pH adjusted and analyzed using a stencil-printed carbon electrode and square wave anodic stripping voltammetry. In this work, a study of 15 neighborhood soils examining the concentration of Pb present post-extraction was performed to demonstrate the method. The limit of detection for the electrochemical analysis was calculated to be 16 ppb-well below the United States Environmental Protection Agency's action limit for Pb in soils (400 mg kg-1 or 4000 ppb)-and third party inductively coupled plasma-optical emission spectroscopy analysis validated the results obtained in this study to within ±17% on average.
Collapse
Affiliation(s)
- Chloe A Beardsley
- Access Sensor Technologies LLC, 320 E. Vine Dr. STE 221, Fort Collins, CO 80524, USA.
| | - Kai Z Fuller
- Access Sensor Technologies LLC, 320 E. Vine Dr. STE 221, Fort Collins, CO 80524, USA.
| | - Thomas H Reilly
- Access Sensor Technologies LLC, 320 E. Vine Dr. STE 221, Fort Collins, CO 80524, USA.
| | - Charles S Henry
- Access Sensor Technologies LLC, 320 E. Vine Dr. STE 221, Fort Collins, CO 80524, USA. .,Department of Chemistry, Colorado State University, 1301 Center Ave., Fort Collins, CO 80523-1872, USA.
| |
Collapse
|
18
|
Green Aspects of Ion Chromatography versus Other Methods in the Analysis of Common Inorganic Ions. SEPARATIONS 2021. [DOI: 10.3390/separations8120235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Due to the increasing environmental awareness of the public, green chemistry has become an important element of environmental protection. In laboratories around the world, millions of analyses of inorganic and organic anions and cations in water and wastewater samples, and solid and gaseous samples are performed daily. Unfortunately, these activities still generate large costs, including environmental costs, which are related to the scale of the studies, the use of toxic chemical reagents, the waste generated, and the energy consumed. The methods used so far for inorganic ion analysis, including classical methods, are increasingly being replaced by instrumental methods, primarily based on ion chromatography. This paper presents the most important advantages and limitations of ion chromatography, and compares them with the costs of classical analyses for the analytes and sample types. Both the financial and environmental costs associated with the determination of common inorganic ions, such as Cl−, NO2−, NO3−, and NH4+, in 1000 environmental samples, were compared using selected reference wet classical methods and ion chromatography. The advantages and limitations of ion chromatography that allow this separation technique to be classified as a green analytical chemistry method have been described herein.
Collapse
|
19
|
Saki EF, Setiawan SA, Wicaksono DHB. Portable Tools for COVID-19 Point-of-Care Detection: A Review. IEEE SENSORS JOURNAL 2021; 21:23737-23750. [PMID: 35582343 PMCID: PMC8864949 DOI: 10.1109/jsen.2021.3110857] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 08/22/2021] [Accepted: 08/26/2021] [Indexed: 06/12/2023]
Abstract
Recently, several methods for SARS-CoV-2 detection have been developed to obtain rapid, portable, cheap, and easy-to-use diagnostic tools. This review paper summarizes and discusses studies on the development of point-of-care devices for SARS-CoV-2 diagnosis with comparisons between them from several aspects. Various detection methods of the recently developed portable COVID-19 biosensor will be presented in this review. The discussion is divided into four major classifications based on the target biomarkers of SARS-CoV-2, such as antibodies, nucleic acids, antigens, and metabolic products. An overview of the potential development for future study is also provided. Moreover, basic knowledge of biosensors is also explained for tutoring the implementation of theory into the research of COVID-19 biosensors. This review paper is aimed to provide a tutorial by collecting the information on the development of a point-of-care device for SARS-CoV-2 detection to provide information for further research and propose the new COVID-19 portable diagnostic tool.
Collapse
Affiliation(s)
- Elga F. Saki
- Department of Biomedical EngineeringFaculty of Life Sciences and TechnologySwiss German University (SGU)Tangerang15143Indonesia
| | | | - Dedy H. B. Wicaksono
- Department of Biomedical EngineeringFaculty of Life Sciences and TechnologySwiss German University (SGU)Tangerang15143Indonesia
| |
Collapse
|
20
|
Origami Paper-Based Electrochemical (Bio)Sensors: State of the Art and Perspective. BIOSENSORS-BASEL 2021; 11:bios11090328. [PMID: 34562920 PMCID: PMC8467589 DOI: 10.3390/bios11090328] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Revised: 08/30/2021] [Accepted: 09/01/2021] [Indexed: 12/30/2022]
Abstract
In the last 10 years, paper-based electrochemical biosensors have gathered attention from the scientific community for their unique advantages and sustainability vision. The use of papers in the design the electrochemical biosensors confers to these analytical tools several interesting features such as the management of the solution flow without external equipment, the fabrication of reagent-free devices exploiting the porosity of the paper to store the reagents, and the unprecedented capability to detect the target analyte in gas phase without any sampling system. Furthermore, cost-effective fabrication using printing technologies, including wax and screen-printing, combined with the use of this eco-friendly substrate and the possibility of reducing waste management after measuring by the incineration of the sensor, designate these type of sensors as eco-designed analytical tools. Additionally, the foldability feature of the paper has been recently exploited to design and fabricate 3D multifarious biosensors, which are able to detect different target analytes by using enzymes, antibodies, DNA, molecularly imprinted polymers, and cells as biocomponents. Interestingly, the 3D structure has recently boosted the self-powered paper-based biosensors, opening new frontiers in origami devices. This review aims to give an overview of the current state origami paper-based biosensors, pointing out how the foldability of the paper allows for the development of sensitive, selective, and easy-to-use smart and sustainable analytical devices.
Collapse
|
21
|
Rocha DS, Duarte LC, Silva-Neto HA, Chagas CL, Santana MH, Antoniosi Filho NR, Coltro WK. Sandpaper-based electrochemical devices assembled on a reusable 3D-printed holder to detect date rape drug in beverages. Talanta 2021; 232:122408. [DOI: 10.1016/j.talanta.2021.122408] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Revised: 04/04/2021] [Accepted: 04/07/2021] [Indexed: 10/21/2022]
|
22
|
Ferrari AGM, Crapnell RD, Banks CE. Electroanalytical Overview: Electrochemical Sensing Platforms for Food and Drink Safety. BIOSENSORS 2021; 11:291. [PMID: 34436093 PMCID: PMC8392528 DOI: 10.3390/bios11080291] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Revised: 08/17/2021] [Accepted: 08/20/2021] [Indexed: 12/13/2022]
Abstract
Robust, reliable, and affordable analytical techniques are essential for screening and monitoring food and water safety from contaminants, pathogens, and allergens that might be harmful upon consumption. Recent advances in decentralised, miniaturised, and rapid tests for health and environmental monitoring can provide an alternative solution to the classic laboratory-based analytical techniques currently utilised. Electrochemical biosensors offer a promising option as portable sensing platforms to expedite the transition from laboratory benchtop to on-site analysis. A plethora of electroanalytical sensor platforms have been produced for the detection of small molecules, proteins, and microorganisms vital to ensuring food and drink safety. These utilise various recognition systems, from direct electrochemical redox processes to biological recognition elements such as antibodies, enzymes, and aptamers; however, further exploration needs to be carried out, with many systems requiring validation against standard benchtop laboratory-based techniques to offer increased confidence in the sensing platforms. This short review demonstrates that electroanalytical biosensors already offer a sensitive, fast, and low-cost sensor platform for food and drink safety monitoring. With continued research into the development of these sensors, increased confidence in the safety of food and drink products for manufacturers, policy makers, and end users will result.
Collapse
Affiliation(s)
| | | | - Craig E. Banks
- Faculty of Science and Engineering, Manchester Metropolitan University, Manchester M1 5GD, UK; (A.G.-M.F.); (R.D.C.)
| |
Collapse
|
23
|
Hasandka A, Prabhu A, Prabhu A, Singhal HR, Nandagopal M S G, Shenoy R, Mani NK. "Scratch it out": carbon copy based paper devices for microbial assays and liver disease diagnosis. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:3172-3180. [PMID: 34169933 DOI: 10.1039/d1ay00764e] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
We present a facile paper-based microfluidic device fabrication technique leveraging off-the-shelf carbon paper for the deposition of hydrophobic barriers using a novel "stencil scratching" method. This exceedingly frugal approach (0.05$) requires practically no technical training to employ. Hydrophobic barriers fabricated using this approach offer a width of 3 mm and a hydrophilic channel width of 849 μm, with an ability to confine major aqueous solvents without leakage. The utility of the device is demonstrated by porting a cell viability assay showing a limit-of-detection (LOD) of 0.6 × 108 CFU mL-1 and bilirubin assay with human serum showing a detection range of 1.76-6.9 mg dL-1 and a limit-of-detection (LOD) of 1.76 mg dL-1. The intuitiveness and economic viability of the fabrication method afford it great potential in the field of point-of-care diagnostics geared towards providing testing infrastructure in resource-scarce regions globally.
Collapse
Affiliation(s)
- Amrutha Hasandka
- Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India.
| | | | | | | | | | | | | |
Collapse
|
24
|
Singhal HR, Prabhu A, Giri Nandagopal M, Dheivasigamani T, Mani NK. One-dollar microfluidic paper-based analytical devices: Do-It-Yourself approaches. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106126] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
25
|
Abstract
Heavy metal pollution of water has become a global issue and is especially problematic in some developing countries. Heavy metals are toxic to living organisms, even at very low concentrations. Therefore, effective and reliable heavy metal detection in environmental water is very important. Current laboratory-based methods used for analysis of heavy metals in water require sophisticated instrumentation and highly trained technicians, making them unsuitable for routine heavy metal monitoring in the environment. Consequently, there is a growing demand for autonomous detection systems that could perform in situ or point-of-use measurements. Microfluidic detection systems, which are defined by their small size, have many characteristics that make them suitable for environmental analysis. Some of these advantages include portability, high sample throughput, reduced reagent consumption and waste generation, and reduced production cost. This review focusses on developments in the application of microfluidic detection systems to heavy metal detection in water. Microfluidic detection strategies based on optical techniques, electrochemical techniques, and quartz crystal microbalance are discussed.
Collapse
|
26
|
Electrochemical micropipette-tip for low-cost environmental applications: Determination of anionic surfactants through their interaction with methylene blue. Talanta 2021; 224:121732. [PMID: 33379002 DOI: 10.1016/j.talanta.2020.121732] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 09/26/2020] [Accepted: 10/01/2020] [Indexed: 11/22/2022]
Abstract
Miniaturization is one of the main requirements in the design of portable devices that allow in-field analysis. This is especially interesting in environmental monitoring, where the time of the sample-to-result process could be decreased considerably by approaching the analytical platforms to the sampling point. We employed traditional mass-produced and low-cost elements (micropipette tips and pins) in an out-of-box application to generate an innovative and cost-effective platform for analytical purposes. We have designed simple and easy-to-use electrochemical cells inside polypropylene micropipette tips with three stainless-steel pins acting as the working, reference and counter electrodes of a potentiostatic system. The pin acting as working electrode was previously coated with carbon ink, meanwhile the rest were used unmodified. In this way, electrochemical in-the-tip measurements were done directly using low volumes (μL) of sample. The devices showed good reproducibility, with a relative standard deviation of 7% (n = 5) for five different tip-based complete electrochemical cells. As a proof-of-concept, its utility has been probed by the determination of an anionic surfactant (sodium dodecyl sulphate, SDS) in water through its interaction with methylene blue (MB). Two different alternatives were presented based on the: 1) increase in the current intensity of the cathodic peak of MB due to the presence of SDS; 2) electrochemical determination of the MB remaining in the aqueous phase after extraction of the pair SDS-MB to an organic medium.
Collapse
|
27
|
An origami paper-based nanoformulated immunosensor detects picograms of VEGF-C per milliliter of blood. Commun Biol 2021; 4:121. [PMID: 33500522 PMCID: PMC7838172 DOI: 10.1038/s42003-020-01607-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2020] [Accepted: 12/16/2020] [Indexed: 11/23/2022] Open
Abstract
Detecting vascular endothelial growth factor C (VEGF-C), a kind of tumor biomarker, is of significant clinical importance in evaluating the prognosis of patients with cancer. However, laboratory analyses are usually not suitable for point-of-care testing because they are expensive and time consuming. In response to these challenges, we fabricated an origami paper-based microfluidic electrochemical device. To improve the specificity of VEGF-C detection, nanocomposites, synthesized by new methylene blue (NMB), amino-functional single-walled carbon nanotubes (NH2-SWCNTs), and gold nanoparticles (AuNPs), were used to modify the surface of working electrodes. Results of electrochemical detection showed that the immunosensor had excellent linearity, ranging from 0.01 to 100 ng mL−1 (R2 = 0.988), and the limit of detection was 10 pg mL−1. To confirm the high specificity of the device under real-world conditions, we evaluated the device using clinical serum samples from our hospital. The results demonstrated that the device had an excellent performance and could provide a platform for real-time detection of cancers. Sun, Wang et al. report an origami paper-based immunosensor for the electrochemical detection of the VEGF-C biomarker in blood serum. The immunosensor is made by modifying the surface of working electrodes with new methylene blue, amino-functional single-walled carbon nanotubes, and gold nanoparticles and demonstrates excellent performance with a limit of detection in the range of picograms per milliliter.
Collapse
|
28
|
Designing Sensing Devices Using Porous Composite Materials. JOURNAL OF COMPOSITES SCIENCE 2021. [DOI: 10.3390/jcs5010035] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
The need for portable and inexpensive analytical devices for various critical issues has led researchers to seek novel materials to construct them. Soft porous materials, such as paper and sponges, are ideal candidates for fabricating such devices due to their light weight and high availability. More importantly, their great compatibility toward modifications and add-ons allows them to be customized to match different objectives. As a result, porous material-based composites have been extensively used to construct sensing devices applied in various fields, such as point-of-care testing, environmental sensing, and human motion detection. In this article, we present fundamental thoughts on how to design a sensing device based on these interesting composite materials and provide correlated examples for reader’s references. First, a rundown of devices made with porous composite materials starting from their fabrication techniques and compatible detection methods is given. Thereafter, illustrations are provided on how device function and property improvements are achieved with a delicate use of composite materials. This includes extending device lifetime by using polymer films to protect the base material, while signal readout can be enhanced by a careful selection of protective cover and the application of advanced photo image analysis techniques. In addition to chemical sensors, mechanical responsive devices based on conductive composite materials are also discussed with a focus on base material selection and platform design. We hope the ideas and discussions presented in this article can help researchers interested in designing sensing devices understand the importance and usefulness of composite materials.
Collapse
|
29
|
Rao LT, Dubey SK, Javed A, Goel S. Development of Membraneless Paper‐pencil Microfluidic Hydrazine Fuel Cell. ELECTROANAL 2020. [DOI: 10.1002/elan.202060191] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Lanka Tata Rao
- Department of Mechanical Engineering BITS Pilani Hyderabad Campus Hyderabad 500078 India
- MEMS, Microfluidics and Nanoelectronics Lab BITS Pilani Hyderabad Campus Hyderabad 500078 India
| | - Satish Kumar Dubey
- Department of Mechanical Engineering BITS Pilani Hyderabad Campus Hyderabad 500078 India
- MEMS, Microfluidics and Nanoelectronics Lab BITS Pilani Hyderabad Campus Hyderabad 500078 India
| | - Arshad Javed
- Department of Mechanical Engineering BITS Pilani Hyderabad Campus Hyderabad 500078 India
- MEMS, Microfluidics and Nanoelectronics Lab BITS Pilani Hyderabad Campus Hyderabad 500078 India
| | - Sanket Goel
- Department of Electrical & Electronics Engineering BITS Pilani Hyderabad Campus Hyderabad 500078 India
- MEMS, Microfluidics and Nanoelectronics Lab BITS Pilani Hyderabad Campus Hyderabad 500078 India
| |
Collapse
|
30
|
Qin Z, Peng R, Baravik IK, Liu X. Fighting COVID-19: Integrated Micro- and Nanosystems for Viral Infection Diagnostics. MATTER 2020; 3:628-651. [PMID: 32838297 PMCID: PMC7346839 DOI: 10.1016/j.matt.2020.06.015] [Citation(s) in RCA: 57] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
The pandemic of coronavirus disease 2019 (COVID-19) highlights the importance of rapid and sensitive diagnostics of viral infection that enables the efficient tracing of cases and the implementation of public health measures for disease containment. The immediate actions from both academia and industry have led to the development of many COVID-19 diagnostic systems that have secured fast-track regulatory approvals and have been serving our healthcare frontlines since the early stage of the pandemic. On diagnostic technologies, many of these clinically validated systems have significantly benefited from the recent advances in micro- and nanotechnologies in terms of platform design, analytical method, and system integration and miniaturization. The continued development of new diagnostic platforms integrating micro- and nanocomponents will address some of the shortcomings we have witnessed in the existing COVID-19 diagnostic systems. This Perspective reviews the previous and ongoing research efforts on developing integrated micro- and nanosystems for nucleic acid-based virus detection, and highlights promising technologies that could provide better solutions for the diagnosis of COVID-19 and other viral infectious diseases. With the summary and outlook of this rapidly evolving research field, we hope to inspire more research and development activities to better prepare our society for future public health crises.
Collapse
Affiliation(s)
- Zhen Qin
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S 3G8, Canada
| | - Ran Peng
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S 3G8, Canada
| | - Ilina Kolker Baravik
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S 3G8, Canada
| | - Xinyu Liu
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S 3G8, Canada
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9, Canada
| |
Collapse
|
31
|
Granica M, Tymecki Ł. Prussian Blue (bio)sensing device for distance-based measurements. Anal Chim Acta 2020; 1136:125-133. [PMID: 33081936 DOI: 10.1016/j.aca.2020.08.037] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2020] [Revised: 07/23/2020] [Accepted: 08/20/2020] [Indexed: 01/12/2023]
Abstract
In this research, microfluidic paper distance-based systems for the quantification of redox species are proposed. For the preparation of the sensing zone a Prussian Blue (PB) (convertible to Prussian White (PW)) layer was deposited in the channel manufactured by wax-printing technique. According to the chemical properties of PB/PW system, it is possible to develop optical sensors sensitive to both oxidizing and reducing agents. The created systems were evaluated for the determination of ascorbic acid and hydrogen peroxide, which were chosen and used as model analytes. The final versions of the proposed systems exhibited a linear response from 0.25 mmol L-1 to 4.0 and 2.0 mmol L-1 for ascorbic acid and H2O2, respectively. The analytical utility of the paper systems was confirmed by measuring the levels of ascorbic acid in dietary supplements. Results correlation obtained for the described systems and the reference method was over 0.98 (Pearson's R-coefficient). All measurements were characterized by satisfactory reproducibility and acceptable uncertainty (RSD (%) < 6%). Finally, it was demonstrated that the modification of the PW-strip systems with oxidoreductase led to an enzymatic assay for glucose up to 10 mmol L-1 range. Practical utility of the developed bio-strips was confirmed by quantifying glucose in drinks and dietary supplement samples.
Collapse
Affiliation(s)
- Mateusz Granica
- University of Warsaw, Faculty of Chemistry, Pasteur 1, 02-093, Warsaw, Poland.
| | - Łukasz Tymecki
- University of Warsaw, Faculty of Chemistry, Pasteur 1, 02-093, Warsaw, Poland
| |
Collapse
|
32
|
Ribeiro MFM, Bento F, Ipólito AJ, de Oliveira MF. Development of a Pencil Drawn Paper-based Analytical Device to Detect Lysergic Acid Diethylamide (LSD)* , †. J Forensic Sci 2020; 65:2121-2128. [PMID: 32602943 DOI: 10.1111/1556-4029.14494] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 05/28/2020] [Accepted: 05/29/2020] [Indexed: 01/04/2023]
Abstract
The need for agile and proper identification of drugs of abuse has encouraged the scientific community to improve and to develop new methodologies. The drug lysergic acid diethylamide (LSD) is still widely used due to its hallucinogenic effects. The use of voltammetric methods to analyze narcotics has increased in recent years, and the possibility of miniaturizing the electrochemical equipment allows these methods to be applied outside the laboratory; for example, in crime scenes. In addition to portability, the search for affordable and sustainable materials for use in electroanalytical research has grown in recent decades. In this context, employing paper substrate, graphite pencil, and silver paint to construct paper-based electrodes is a great alternative. Here, a paper-based device comprising three electrodes was drawn on 300 g/m2 watercolor paper with 8B pencils, and its efficiency was compared to the efficiency of a commercially available screen-printed carbon electrode. Square wave voltammetry was used for LSD analysis in aqueous medium containing 0.05 mol/L LiClO4 . The limits of detection and quantification were 0.38 and 1.27 μmol/L, respectively. Both electrodes exhibited a similar voltammetric response, which was also confirmed during analysis of a seized LSD sample, with recovery of less than 10%. The seized samples were previously analyzed by GCMS technique, employing the full scan spectra against the software spectral library. The electrode selectivity was also tested against 3,4-methylenedioxymethamphetamine (MDMA) and methamphetamine. It was possible to differentiate these compounds from LSD, indicating that the developed paper-based device has potential application in forensic chemistry analyses.
Collapse
Affiliation(s)
| | - Fátima Bento
- Centro de Química, Universidade do Minho, Campus de Gualtar, Braga, 4710 - 057, Portugal
| | - Antônio J Ipólito
- Superintendência Polícia Técnica Científica, SPTC, Rua São Sebastião, Ribeirão Preto, SP, 1339, Brazil
| | - Marcelo F de Oliveira
- Universidade de São Paulo, USP, Avenida Bandeirantes, Ribeirão Preto, SP, 3900, Brazil
| |
Collapse
|
33
|
Use of an ether-derived 3-hydroxy-4-pyridinone chelator as a new chromogenic reagent in the development of a microfluidic paper-based analytical device for Fe(III) determination in natural waters. Talanta 2020; 214:120887. [PMID: 32278410 DOI: 10.1016/j.talanta.2020.120887] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2019] [Revised: 02/27/2020] [Accepted: 02/28/2020] [Indexed: 11/21/2022]
Abstract
This article reports on the development and validation of a disposable microfluidic paper-based analytical device (μPAD) for on-hand, in-situ, and cheap Fe(III) determination in natural waters complying with World Health Organization guidelines. The developed μPAD used 3-hydroxy-4-pyridinone (3,4-HPO) as a colour reagent due to its considerably lower toxicity than traditionally used iron analytical reagents. It was selected among a group of hydrophilic 3,4-HPO chelators containing ether-derived chains in their structure which were prepared using green methods. The relatively high water solubility of these chelators improved the detection limit and applicability as μPAD reagents. Under optimal conditions, the μPAD is characterised by a quantification range between 0.25 and 2.0 mg/L, a detection limit of 55 μg/L and 15 min of analysis time. The signal stability extends up to 4 h and the device is stable for at least one month. The reagent consumption is below 0.2 mg per analysis and the μPAD method was validated by analysis certified reference materials and by comparison with atomic absorption results (RD < 10%). The newly developed μPAD was successfully applied to the determination of iron in river, well and tap waters with no need of any prior sample pre-treatment.
Collapse
|
34
|
Ozer T, McMahon C, Henry CS. Advances in Paper-Based Analytical Devices. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2020; 13:85-109. [PMID: 31986055 DOI: 10.1146/annurev-anchem-061318-114845] [Citation(s) in RCA: 134] [Impact Index Per Article: 33.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Microfluidic paper-based analytical devices (μPADs) are the newest generation of lab-on-a-chip devices and have made significant strides in both our understanding of fundamental behavior and performance characteristics and expansion of their applications. μPADs have become useful analytical techniques for environmental analysis in addition to their more common application as medical point-of-care devices. Although the most common method for device fabrication is wax printing, numerous other techniques exist and have helped address factors ranging from solvent compatibility to improved device function. This review highlights recent reports of fabrication and design, modes of detection, and broad applications of μPADs. Such advances have enabled μPADs to be used in field and laboratory studies to address critical needs in fast, cheaper measurement technologies.
Collapse
Affiliation(s)
- Tugba Ozer
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80526, USA;
- Department of Bioengineering, Yildiz Technical University, Istanbul 34220, Turkey
| | - Catherine McMahon
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80526, USA;
| | - Charles S Henry
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80526, USA;
| |
Collapse
|
35
|
Nunez-Bajo E, Fernández-Abedul MT. Paper-based platforms with coulometric readout for ascorbic acid determination in fruit juices. Analyst 2020; 145:3431-3439. [PMID: 32259174 DOI: 10.1039/d0an00477d] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
There is growing interest in the development of simple, fast, sustainable and low-cost analytical methodologies on paper-based platforms. However, sensitive detection strategies that fit properly with these devices are still required. In this work, a calibration-free method is proposed for analytical determinations performed on paper-based electrochemical devices, in this case, for ascorbic acid. Carbon ink is deposited on a hydrophilic working area of the paper delimited with a hydrophobic wax. This maskless procedure is fast and cuts down ink waste. The connection of this working electrode to the potentiostat is provided by reusable gold-plated connector headers that provide also the reference and counter electrodes. The thickness of the paper substrate defines the electrochemical cell and confines a sample volume, ideal for thin-layer coulometry. Controlled-potential coulometry is performed applying a potential of +0.6 V for 50 s. The charge is calculated by measuring the area under the fast chronoamperogram and the concentration is determined following Faraday's law (known number of transferred electrons). This methodology was applied to the determination of ascorbic acid, with a limit of detection of 40 μM. Its concentration in commercial fruit juices can be directly determined in diluted samples. The absence of matrix effects is observed by comparing the results obtained before and after enzymatic reaction of the sample with cucumber ascorbate oxidase. Good accuracy and precision makes this method suitable for quality control of ascorbic acid in commercial juices. Underexploited coulometric readout can be applied as a fast (calibration-free) and low-cost (standards not required) transduction principle for the newly developed paper devices.
Collapse
Affiliation(s)
- Estefanía Nunez-Bajo
- Departamento de Química Física y Analítica, Universidad de Oviedo, Asturias, Spain.
| | | |
Collapse
|
36
|
Wang H, Bo X, Zhou M, Guo L. DUT-67 and tubular polypyrrole formed a cross-linked network for electrochemical detection of nitrofurazone and ornidazole. Anal Chim Acta 2020; 1109:1-8. [DOI: 10.1016/j.aca.2020.03.002] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Revised: 02/22/2020] [Accepted: 03/02/2020] [Indexed: 12/14/2022]
|
37
|
Antonacci A, Scognamiglio V, Mazzaracchio V, Caratelli V, Fiore L, Moscone D, Arduini F. Paper-Based Electrochemical Devices for the Pharmaceutical Field: State of the Art and Perspectives. Front Bioeng Biotechnol 2020; 8:339. [PMID: 32391344 PMCID: PMC7190989 DOI: 10.3389/fbioe.2020.00339] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2019] [Accepted: 03/27/2020] [Indexed: 12/19/2022] Open
Abstract
The current international pharmaceutical scenario encompasses several steps in drug production, with complex and extremely long procedures. In the last few decades, scientific research has been trying to offer valid and reliable solutions to replace or support conventional techniques, in order to facilitate drug development procedures. These innovative approaches may have extremely positive effects in the production chain, supplying fast, and cost-effective quality as well as safety tests on active pharmaceutical ingredients (APIs) and their excipients. In this context, the exploitation of electrochemical paper-based analytical devices (ePADs) is still in its infancy, but is particularly promising in the detection of APIs and excipients in tablets, capsules, suppositories, and injections, as well as for pharmacokinetic bioanalysis in real samples.
Collapse
Affiliation(s)
- Amina Antonacci
- Department of Chemical Sciences and Materials Technologies, Institute of Crystallography, National Research Council, Rome, Italy
| | - Viviana Scognamiglio
- Department of Chemical Sciences and Materials Technologies, Institute of Crystallography, National Research Council, Rome, Italy
| | - Vincenzo Mazzaracchio
- Department of Chemical Science and Technologies, Tor Vergata University, Rome, Italy
| | - Veronica Caratelli
- Department of Chemical Science and Technologies, Tor Vergata University, Rome, Italy
| | - Luca Fiore
- Department of Chemical Science and Technologies, Tor Vergata University, Rome, Italy
| | - Danila Moscone
- Department of Chemical Science and Technologies, Tor Vergata University, Rome, Italy
| | - Fabiana Arduini
- Department of Chemical Science and Technologies, Tor Vergata University, Rome, Italy.,SENSE4MED, Rome, Italy
| |
Collapse
|
38
|
Sassa F, Biswas GC, Suzuki H. Microfabricated electrochemical sensing devices. LAB ON A CHIP 2020; 20:1358-1389. [PMID: 32129358 DOI: 10.1039/c9lc01112a] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Electrochemistry provides possibilities to realize smart microdevices of the next generation with high functionalities. Electrodes, which constitute major components of electrochemical devices, can be formed by various microfabrication techniques, and integration of the same (or different) components for that purpose is not difficult. Merging this technique with microfluidics can further expand the areas of application of the resultant devices. To augment the development of next generation devices, it will be beneficial to review recent technological trends in this field and clarify the directions required for moving forward. Even when limiting the discussion to electrochemical microdevices, a variety of useful techniques should be considered. Therefore, in this review, we attempted to provide an overview of all relevant techniques in this context in the hope that it can provide useful comprehensive information.
Collapse
Affiliation(s)
- Fumihiro Sassa
- Graduate School of Information Science and Electrical Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka, 819-0395, Japan
| | | | | |
Collapse
|
39
|
Schaumburg F, Kler PA, Berli CLA. Comprehensive model of electromigrative transport in microfluidic paper based analytical devices. Electrophoresis 2020; 41:598-606. [DOI: 10.1002/elps.201900353] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2019] [Revised: 11/28/2019] [Accepted: 12/08/2019] [Indexed: 11/06/2022]
Affiliation(s)
- Federico Schaumburg
- INTEC (Universidad Nacional del Litoral–CONICET)Colectora RN 168 Km 472 S3000GLN Santa Fe Argentina
| | - Pablo A. Kler
- CIMEC (Universidad Nacional del Litoral–CONICET)Colectora RN 168 Km 472 S3000GLN Santa Fe Argentina
- Departamento de Ingeniería en Sistemas de InformaciónFRSF‐UTN.Lavaise 610 S3004EWB Santa Fe Argentina
| | - Claudio L. A. Berli
- INTEC (Universidad Nacional del Litoral–CONICET)Colectora RN 168 Km 472 S3000GLN Santa Fe Argentina
| |
Collapse
|
40
|
Cytokine and Cancer Biomarkers Detection: The Dawn of Electrochemical Paper-Based Biosensor. SENSORS 2020; 20:s20071854. [PMID: 32230808 PMCID: PMC7180619 DOI: 10.3390/s20071854] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Revised: 03/24/2020] [Accepted: 03/24/2020] [Indexed: 12/14/2022]
Abstract
Although the established ELISA-based sensing platforms have many benefits, the importance of cytokine and cancer biomarkers detection for point-of-care diagnostics has propelled the search for more specific, sensitive, simple, accessible, yet economical sensor. Paper-based biosensor holds promise for future in-situ applications and can provide rapid analysis and data without the need to conduct in a laboratory. Electrochemical detection plays a vital role in interpreting results obtained from qualitative assessment to quantitative determination. In this review, various factors affecting the design of an electrochemical paper-based biosensor are highlighted and discussed in depth. Different detection methods, along with the latest development in utilizing them in cytokine and cancer biomarkers detection, are reviewed. Lastly, the fabrication of portable electrochemical paper-based biosensor is ideal in deliberating positive societal implications in developing countries with limited resources and accessibility to healthcare services.
Collapse
|
41
|
Chitosan–Fe3O4 nanoparticle enzymatic electrodes on paper as an efficient assay for glucose and uric acid detection in biological fluids. CHEMICAL PAPERS 2020. [DOI: 10.1007/s11696-020-01105-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
42
|
Sudhakara Prasad K, Cao X, Gao N, Jin Q, Sanjay ST, Henao-Pabon G, Li X. A Low-Cost Nanomaterial-based Electrochemical Immunosensor on Paper for High-Sensitivity Early Detection of Pancreatic Cancer. SENSORS AND ACTUATORS. B, CHEMICAL 2020; 305:127516. [PMID: 32863588 PMCID: PMC7453835 DOI: 10.1016/j.snb.2019.127516] [Citation(s) in RCA: 69] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Due to the lack of specific early detection methods for pancreatic cancer, it usually goes undetected until it is advanced. By employing paper-based electrodes (PPE), herein we for the first time developed a disposable low-cost paper-based immunosensor for rapid early quantitative detection of pancreatic cancer with a new biomarker, pseudopodium-enriched atypical kinase one, SGK269 (PEAK1). The immunosensor was constructed by fabricating PPEs immobilized with the versatile nanomaterial graphene oxide for the incorporation of antibodies to form an immunosensing platform, without the need of complicated surface modification. After it was confirmed that the PPEs exhibited excellent electrochemical properties, a sandwich-type electrochemical immunosensor was subsequently constructed by employing graphene oxide layers immobilized with anti-PEAK1, and the antibody conjugated with gold nanoparticles (AuNPs-tagged-Anti PEAK1). Further, spectral and surface characteristic studies confirmed the formation of the immunosensing platform. The immunosensor for PEAK1 exhibited a wide linear range between 10 pg mL-1 and 106 pg mL-1 with a low limit of detection (LOD) of 10 pg mL-1. The obtained results point towards rapid, sensitive, and specific early diagnosis of pancreatic cancer at the point of care and other low-resource settings.
Collapse
Affiliation(s)
- K. Sudhakara Prasad
- Department of Chemistry & Biochemistry, University of Texas at El Paso, Texas, USA
| | - Xiyue Cao
- Department of Chemistry & Biochemistry, University of Texas at El Paso, Texas, USA
- College of Chemistry and Chemical Engineering, Qingdao University, Qingdao, 266071, PR China
| | - Ning Gao
- Department of Chemistry & Biochemistry, University of Texas at El Paso, Texas, USA
| | - Qijie Jin
- Department of Chemistry & Biochemistry, University of Texas at El Paso, Texas, USA
- College of Materials Science and Engineering, Nanjing Tech University, Nanjing 210009, PR China
| | - Sharma T. Sanjay
- Department of Chemistry & Biochemistry, University of Texas at El Paso, Texas, USA
| | - Gilberto Henao-Pabon
- Biomedical Engineering, Border Biomedical Research Center, and Environmental Science & Engineering, University of Texas at El Paso, USA
| | - XiuJun Li
- Department of Chemistry & Biochemistry, University of Texas at El Paso, Texas, USA
- Biomedical Engineering, Border Biomedical Research Center, and Environmental Science & Engineering, University of Texas at El Paso, USA
- Corresponding Author: XiuJun Li,
| |
Collapse
|
43
|
Pradela-Filho LA, Noviana E, Araújo DAG, Takeuchi RM, Santos AL, Henry CS. Rapid Analysis in Continuous-Flow Electrochemical Paper-Based Analytical Devices. ACS Sens 2020; 5:274-281. [PMID: 31898461 DOI: 10.1021/acssensors.9b02298] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
A simple and low-cost continuous-flow (CF) electrochemical paper-based analytical device (ePAD) coupled with thermoplastic electrodes (TPEs) was developed. The fast, continuous flow combined with flow injection analysis was made possible by adding two inlet reservoirs to the same paper-based hollow channel flowing over detection electrodes, terminating in a fan-shaped pumping reservoir. The upstream inlet reservoir was filled with buffer and provided constant flow through the device. Sample injections were performed by adding 2 μL of the sample to the downstream sample inlet. Differences in flow resistance resulted in sample plugs displacing buffer as the solution flowed over the working electrodes. The electrodes were fabricated by mixing carbon black and polycaprolactone (50% w/w). CF-TPE-ePADs were characterized with chronoamperometry using ferrocenylmethyl trimethylammonium as the electrochemical probe. Optimized flow rates and injection volumes gave analysis times roughly an order of magnitude faster than those of previously reported flow injection analysis ePADs. To demonstrate applicability, the CF-TPE-ePADs were used to quantify caffeic acid in three different tea samples. The proposed method had a linear range from 10 to 500 μmol L-1 and limits of detection and quantification of 2.5 and 8.3 μmol L-1, respectively. Our approach is promising for fabricating simple, inexpensive, yet high-performance, flow injection analysis devices using paper substrates and easy-to-make electrodes that do not require external mechanical pumping systems or complicated valves.
Collapse
Affiliation(s)
- Lauro A. Pradela-Filho
- Instituto de Química, Universidade Federal de Uberlândia, Av. João Naves de Ávila, 2121, Minas Gerais, Uberlândia, MG 38400-902, Brasil
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Eka Noviana
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Universitas Gadjah Mada, Yogyakarta 55281, Indonesia
| | - Diele A. G. Araújo
- Instituto de Química, Universidade Federal de Uberlândia, Av. João Naves de Ávila, 2121, Minas Gerais, Uberlândia, MG 38400-902, Brasil
| | - Regina M. Takeuchi
- Instituto de Química, Universidade Federal de Uberlândia, Av. João Naves de Ávila, 2121, Minas Gerais, Uberlândia, MG 38400-902, Brasil
| | - André L. Santos
- Instituto de Química, Universidade Federal de Uberlândia, Av. João Naves de Ávila, 2121, Minas Gerais, Uberlândia, MG 38400-902, Brasil
| | - Charles S. Henry
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| |
Collapse
|
44
|
Noviana E, McCord CP, Clark KM, Jang I, Henry CS. Electrochemical paper-based devices: sensing approaches and progress toward practical applications. LAB ON A CHIP 2020; 20:9-34. [PMID: 31620764 DOI: 10.1039/c9lc00903e] [Citation(s) in RCA: 140] [Impact Index Per Article: 35.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Paper-based sensors offer an affordable yet powerful platform for field and point-of-care (POC) testing due to their self-pumping ability and utility for many different analytical measurements. When combined with electrochemical detection using small and portable electronics, sensitivity and selectivity of the paper devices can be improved over naked eye detection without sacrificing portability. Herein, we review how the field of electrochemical paper-based analytical devices (ePADs) has grown since it was introduced a decade ago. We start by reviewing fabrication methods relevant to ePADs with more focus given to the electrode fabrication, which is fundamental for electrochemical sensing. Multiple sensing approaches applicable to ePADs are then discussed and evaluated to present applicability, advantages and challenges associated with each approach. Recent applications of ePADs in the fields of clinical diagnostics, environmental testing, and food analysis are also presented. Finally, we discuss how the current ePAD technologies have progressed to meet the analytical and practical specifications required for field and/or POC applications, as well as challenges and outlook.
Collapse
Affiliation(s)
- Eka Noviana
- Department of Chemistry, Colorado State University, Fort Collins, CO, USA. and Department of Pharmaceutical Chemistry, School of Pharmacy, Universitas Gadjah Mada, Yogyakarta, Indonesia
| | - Cynthia P McCord
- Department of Chemistry, Colorado State University, Fort Collins, CO, USA.
| | - Kaylee M Clark
- Department of Chemistry, Colorado State University, Fort Collins, CO, USA.
| | - Ilhoon Jang
- Department of Chemistry, Colorado State University, Fort Collins, CO, USA. and Institute of Nano Science and Technology, Hanyang University, Seoul, South Korea
| | - Charles S Henry
- Department of Chemistry, Colorado State University, Fort Collins, CO, USA.
| |
Collapse
|
45
|
Wang Y, Sun S, Luo J, Xiong Y, Ming T, Liu J, Ma Y, Yan S, Yang Y, Yang Z, Reboud J, Yin H, Cooper JM, Cai X. Low sample volume origami-paper-based graphene-modified aptasensors for label-free electrochemical detection of cancer biomarker-EGFR. MICROSYSTEMS & NANOENGINEERING 2020; 6:32. [PMID: 34567646 PMCID: PMC8433370 DOI: 10.1038/s41378-020-0146-2] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Revised: 12/04/2019] [Accepted: 02/18/2020] [Indexed: 05/08/2023]
Abstract
In this work, an electrochemical paper-based aptasensor was fabricated for label-free and ultrasensitive detection of epidermal growth factor receptor (EGFR) by employing anti-EGFR aptamers as the bio-recognition element. The device used the concept of paper-folding, or origami, to serve as a valve between sample introduction and detection, so reducing sampling volumes and improving operation convenience. Amino-functionalized graphene (NH2-GO)/thionine (THI)/gold particle (AuNP) nanocomposites were used to modify the working electrode not only to generate the electrochemical signals, but also to provide an environment conducive to aptamer immobilization. Electrochemical characterization revealed that the formation of an insulating aptamer-antigen immunocomplex would hinder electron transfer from the sample medium to the working electrode, thus resulting in a lower signal. The experimental results showed that the proposed aptasensor exhibited a linear range from 0.05 to 200 ngmL-1 (R 2 = 0.989) and a detection limit of 5 pgmL-1 for EGFR. The analytical reliability of the proposed paper-based aptasensor was further investigated by analyzing serum samples, showing good agreement with the gold-standard enzyme-linked immunosorbent assay.
Collapse
Affiliation(s)
- Yang Wang
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, 100190 China
- University of Chinese Academy of Sciences, Beijing, 100190 China
| | - Shuai Sun
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, 100190 China
- University of Chinese Academy of Sciences, Beijing, 100190 China
| | - Jinping Luo
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, 100190 China
- University of Chinese Academy of Sciences, Beijing, 100190 China
| | - Ying Xiong
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education), Department of Thoracic Surgery II, Peking University Cancer Hospital & Institute, Beijing, 100142 China
| | - Tao Ming
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, 100190 China
- University of Chinese Academy of Sciences, Beijing, 100190 China
| | - Juntao Liu
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, 100190 China
- University of Chinese Academy of Sciences, Beijing, 100190 China
| | - Yuanyuan Ma
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education), Department of Thoracic Surgery II, Peking University Cancer Hospital & Institute, Beijing, 100142 China
| | - Shi Yan
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education), Department of Thoracic Surgery II, Peking University Cancer Hospital & Institute, Beijing, 100142 China
| | - Yue Yang
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education), Department of Thoracic Surgery II, Peking University Cancer Hospital & Institute, Beijing, 100142 China
| | - Zhugen Yang
- Division of Biomedical Engineering, James Watt School of Engineering, University of Glasgow, Oakfield Avenue, Glasgow, G12 8LT United Kingdom
| | - Julien Reboud
- Division of Biomedical Engineering, James Watt School of Engineering, University of Glasgow, Oakfield Avenue, Glasgow, G12 8LT United Kingdom
| | - Huabing Yin
- Division of Biomedical Engineering, James Watt School of Engineering, University of Glasgow, Oakfield Avenue, Glasgow, G12 8LT United Kingdom
| | - Jonathan M. Cooper
- Division of Biomedical Engineering, James Watt School of Engineering, University of Glasgow, Oakfield Avenue, Glasgow, G12 8LT United Kingdom
| | - Xinxia Cai
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, 100190 China
- University of Chinese Academy of Sciences, Beijing, 100190 China
| |
Collapse
|
46
|
Kava AA, Beardsley C, Hofstetter J, Henry CS. Disposable glassy carbon stencil printed electrodes for trace detection of cadmium and lead. Anal Chim Acta 2019; 1103:58-66. [PMID: 32081189 DOI: 10.1016/j.aca.2019.12.047] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2019] [Revised: 11/25/2019] [Accepted: 12/16/2019] [Indexed: 12/20/2022]
Abstract
Cadmium (Cd) and lead (Pb) pollution is a significant environmental and human health concern, and methods to detect Cd and Pb on site are valuable. Stencil-printed carbon electrodes (SPCEs) are an attractive electrode material for point-of-care (POC) applications due to their low cost, ease of fabrication, disposability and portability. At present, SPCEs are exclusively formulated from graphitic carbon powder and conductive carbon ink. However, graphitic carbon SPCEs are not ideal for heavy metal sensing due to the heterogeneity of graphitic SPCE surfaces. Moreover, SPCEs typically require extensive modification to provide desirable detection limits and sensitivity at the POC, significantly increasing cost and complexity of analysis. While there are many examples of chemically modified SPCEs, the bulk SPCE composition has not been studied for heavy metal detection. Here, a glassy carbon microparticle stencil printed electrode (GC-SPE) was developed. The GC-SPEs were first characterized with SEM and cyclic voltammetry and then optimized for Cd and Pb detection with an in situ Bi-film plated. The GC-SPEs require no chemical modification or pretreatment significantly decreasing the cost and complexity of fabrication. The detection limits for Cd and Pb were estimated to be 0.46 μg L-1 and 0.55 μg L-1, respectively, which are below EPA limits for drinking water (5 μg L-1 Cd and 10 μg L-1 Pb) [1]. The reported GC-SPEs are advantageous with their low cost, ease of fabrication and use, and attractive performance. The GC-SPEs can be used for low-level metal detection at the POC as shown in the report herein.
Collapse
Affiliation(s)
- Alyssa A Kava
- Department of Chemistry, Colorado State University, Fort Collins, CO, 80523, United States
| | - Chloe Beardsley
- Department of Chemistry, Colorado State University, Fort Collins, CO, 80523, United States; Access Sensor Technologies, Fort Collins, CO, 80526, United States
| | | | - Charles S Henry
- Department of Chemistry, Colorado State University, Fort Collins, CO, 80523, United States.
| |
Collapse
|
47
|
González-López A, Blanco-López MC, Fernández-Abedul MT. Micropipette Tip-Based Immunoassay with Electrochemical Detection of Antitissue Transglutaminase to Diagnose Celiac Disease Using Staples and a Paper-Based Platform. ACS Sens 2019; 4:2679-2687. [PMID: 31497948 DOI: 10.1021/acssensors.9b01096] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
In this work, 1-200 μL polypropylene micropipette tips were used as platforms for performing immunoassays after converting their inner surfaces on a capture zone for the analyte of interest. We have used a micropipette-tip immunoelectroanalytical platform for the detection of antitissue transglutaminase (IgA), the main biomarker for celiac disease. Modification of the tip wall with poly-l-lysine allowed adsorption of tissue transglutaminase (tTG), which will capture later anti-tTG (IgA) antibodies developed in celiac-affected people. A sandwich-type format was followed, incubating simultaneously the analyte and the detection antibody, labeled with horseradish peroxidase. With this new application for an extremely common lab material, we can perform quantitative analysis by dispensing the liquid into a low-cost and miniaturized staple-based paper electrochemical platform. The analytical signal was the reduction of the enzymatically oxidized substrate, recorded chronoamperometrically (i-t curve). The intensity of the current obtained at a fixed time after the application of the cathodic potential followed a linear relationship with anti-tTG (IgA) concentration. The relative standard deviation obtained for immunoassays performed in different tips indicates the adequate precision of this new methodology, which is very promising for decentralized analysis. Negative and positive controls produced results that were in accordance with those obtained with spectrophotometric enzyme linked-immunosorbent assays.
Collapse
Affiliation(s)
- Andrea González-López
- Department of Physical and Analytical Chemistry, University of Oviedo, 33006 Oviedo, Spain
| | | | | |
Collapse
|
48
|
Xu B, Guo J, Fu Y, Chen X, Guo J. A review on microfluidics in the detection of food pesticide residues. Electrophoresis 2019; 41:821-832. [PMID: 31525822 DOI: 10.1002/elps.201900209] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Revised: 08/28/2019] [Accepted: 08/30/2019] [Indexed: 12/29/2022]
Abstract
This paper briefly explains the food safety problems related to pesticide residues and introduces microfluidics technology as a pesticide residue detection method. Three mainstream microfluidic detection devices are detailed: one driven by liquid surface tension, one by motor siphon drive, and one by centrifugal force. The advantages and disadvantages of each are considered in an analysis of future trends in microfluidic technology for pesticide detection.
Collapse
Affiliation(s)
- Bangbang Xu
- School of Information and Communication Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| | - Jiuchuan Guo
- School of Information and Communication Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| | - Yusheng Fu
- School of Information and Communication Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| | - Xinyu Chen
- School of Information and Communication Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| | - Jinhong Guo
- School of Information and Communication Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| |
Collapse
|
49
|
Chronometric Quantitation of Analytes in Paper-Based Microfluidic Devices (MicroPADs) via Enzymatic Degradation of a Metastable Biomatrix. INVENTIONS 2019. [DOI: 10.3390/inventions4030048] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The following article summarizes United States Patent Application No. US20180052155A1, titled ‘Assay Devices and Methods’ (filed 16 August 2016, published 22 February 2018). While lateral flow assays (LFAs) have revolutionized point-of-care diagnostics by enabling accurate, inexpensive, and rapid detection of biomarkers, they typically do not provide quantitative results. Hence, there is a significant need for quantitative assays at the point of care. This patent summary describes a novel method of chronometric biomarker quantitation via enzymatic degradation of a metastable gelatin-based biomatrix, principally suited for use in paper-based microfluidic devices (microPADs). This new quantitation mechanism was designed to meet the ASSURED criteria for point-of-care diagnostic devices laid forth by the World Health Organization and may ultimately provide increased access to healthcare, at a significantly reduced cost, around the world.
Collapse
|
50
|
Moreira CM, Scala-Benuzzi ML, Takara EA, Pereira SV, Regiart M, Soler-Illia GJ, Raba J, Messina GA. Paper surface modification strategies employing N-SBA-15/polymer composites in bioanalytical sensor design. Talanta 2019; 200:186-192. [DOI: 10.1016/j.talanta.2019.03.051] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Revised: 03/12/2019] [Accepted: 03/13/2019] [Indexed: 12/20/2022]
|