1
|
Reymond N, Estoppey N, Weyermann C, Glanzmann V. Breaking barriers in passive sampling: The potential of PTFE membranes in the monitoring of hydrophilic micropollutants. JOURNAL OF HAZARDOUS MATERIALS 2024; 475:134853. [PMID: 38878431 DOI: 10.1016/j.jhazmat.2024.134853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Revised: 05/22/2024] [Accepted: 06/06/2024] [Indexed: 06/27/2024]
Abstract
Passive samplers are key tools to sample hydrophilic micropollutants in water. Two main approaches address the influence of hydrodynamics: (1) determining site-specific sampling rate (RS) by characterizing kw, the mass transfer coefficient of the water-boundary layer (WBL), and (2) reducing WBL impact using a diffusive material to control the uptake. The first requires calibration data and the second has only been achieved using fragile diffusive material. This study assesses the transfer of hydrophilic contaminants through polytetrafluoroethylene (PTFE; 30 µm thick), a new membrane material with lower sorption than commonly used polyethersulfone (PES). Combined for the first time in a Chemcatcher-like configuration, we calibrated the modified samplers for 44 micropollutants to provide RS - kw relationships for in-situ RS determination (approach 1). Micropollutants accumulated over 2000 times more on the sorbent than on PTFE. PTFE-based RS (0.027 to 0.300 L day-1) were 2.5 higher than previously reported with PES. Membrane property measurements (porosity, tortuosity) indicated that accumulation is primarily controlled by the membrane. Extrapolation indicated that using thicker PTFE membranes (≥ 100 µm) would shift uptake control entirely to the membrane in river conditions (approach 2). This finding could enable RS prediction based on contaminants properties, thus representing a significant advancement in passive sampling.
Collapse
Affiliation(s)
- Naomi Reymond
- School of Criminal Justice, University of Lausanne, Batochime building, Lausanne 1015, Switzerland.
| | - Nicolas Estoppey
- Norwegian Geotechnical Institute (NGI), P.O. Box 3930, Ullevål Stadion, Oslo N-0806, Norway.
| | - Céline Weyermann
- School of Criminal Justice, University of Lausanne, Batochime building, Lausanne 1015, Switzerland
| | - Vick Glanzmann
- School of Criminal Justice, University of Lausanne, Batochime building, Lausanne 1015, Switzerland
| |
Collapse
|
2
|
Becker B, Kochleus C, Spira D, Bachtin J, König F, Meinecke S, Möhlenkamp C, Booij K. Modelling passive sampling of hydrophilic compounds under time-variable aqueous concentrations. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2024:10.1007/s11356-024-34460-x. [PMID: 39129044 DOI: 10.1007/s11356-024-34460-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Accepted: 07/19/2024] [Indexed: 08/13/2024]
Abstract
Passive sampling is a crucial method for evaluating concentrations of hydrophilic organic compounds in the aquatic environment, but it is insufficiently understood to what extent passive samplers capture the intermittent emissions that frequently occur for this group of compounds. In the present study, silicone sheets and styrene-divinyl benzene-reversed phase sulfonated extraction disks with and without a polyethersulfone membrane were exposed under semi-field conditions in a 31 m3 flume at three different flow velocities. Natural processes and spiking/dilution measures caused aqueous concentrations to vary strongly with time. The data were analyzed using two analytical models that account for these time-variable concentrations: a sampling rate model and a diffusion model. The diffusion model generally gave a better fit of the data than the sampling rate model, but the difference in residual errors was quite small (median errors of 19 vs. 25% for silicone and 22 vs. 25% for SDB-RPS samplers). The sampling rate model was therefore adequate enough to evaluate the time-integrative capabilities of the samplers. Sampler performance was best for SDB-RPS samplers with a polyethersulfone membrane, despite the occurrence of lag times for some compounds (0.1 to 0.4 days). Sampling rates for this design also spanned a narrower range (80 to 110 mL/day) than SDB-RPS samplers without a membrane (100 to 660 mL/day). The effect of biofouling was similar for all compounds and was consistent with a biofouling layer thickness of 150 µm.
Collapse
Affiliation(s)
- Benjamin Becker
- Federal Institute of Hydrology (BfG), Am Mainzer Tor 1, 56068, Koblenz, Germany.
| | - Christian Kochleus
- Federal Institute of Hydrology (BfG), Am Mainzer Tor 1, 56068, Koblenz, Germany
| | - Denise Spira
- Federal Institute of Hydrology (BfG), Am Mainzer Tor 1, 56068, Koblenz, Germany
| | - Julia Bachtin
- Federal Institute of Hydrology (BfG), Am Mainzer Tor 1, 56068, Koblenz, Germany
| | - Fabian König
- German Environment Agency (UBA), Schichauweg 58, 12307, Berlin, Germany
| | - Stefan Meinecke
- German Environment Agency (UBA), Schichauweg 58, 12307, Berlin, Germany
| | - Christel Möhlenkamp
- Federal Institute of Hydrology (BfG), Am Mainzer Tor 1, 56068, Koblenz, Germany
| | - Kees Booij
- PaSOC, Greate Pierwei 25, 8821 LV, Kimswerd, The Netherlands
| |
Collapse
|
3
|
Vinyes-Nadal M, Masbou J, Kümmel S, Gehre M, Imfeld G, Otero N, Torrentó C. Novel extraction methods and compound-specific isotope analysis of methoxychlor in environmental water and aquifer slurry samples. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 931:172858. [PMID: 38714260 DOI: 10.1016/j.scitotenv.2024.172858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Revised: 04/26/2024] [Accepted: 04/26/2024] [Indexed: 05/09/2024]
Abstract
Multi-element compound-specific stable isotope analysis (ME-CSIA) allows monitoring the environmental behavior and transformation of most common and persistent contaminants. Recent advancements in analytical techniques have extended the applicability of ME-CSIA to organic micropollutants, including pesticides. Nevertheless, the application of this methodology remains unexplored concerning harmful insecticides such as methoxychlor, a polar organochlorine pesticide usually detected in soil and groundwater. This study introduces methods for dual carbon and chlorine compound-specific stable isotope analysis (δ13C-CSIA and δ37Cl-CSIA) of both methoxychlor and its metabolite, methoxychlor olefin, with a sensitivity down to 10 and 100 mg/L, and a precision lower than 0.3 and 0.5 ‰ for carbon and chlorine CSIA, respectively. Additionally, three extraction and preconcentration techniques suitable for ME-CSIA of the target pesticides at environmentally relevant concentrations were also developed. Solid-phase extraction (SPE) and liquid-solid extraction (LSE) effectively extracted methoxychlor (107 ± 27 % and 87 ± 13 %, respectively) and its metabolite (91 ± 27 % and 106 ± 14 %, respectively) from water and aquifer slurry samples, respectively, with high accuracy (Δδ13C and Δδ37Cl ≤ ± 1 ‰). Combining CSIA with polar organic chemical integrative samplers (POCISs) for the extraction of methoxychlor and methoxychlor olefin from water samples resulted in insignificant fractionation for POCIS-CSIA (Δδ13C ≤ ± 1 ‰). A relevant sorption of methoxychlor was detected within the polyethersulfones membranes of the POCISs resulting in temporary carbon isotope fractionation depending on the sorbed mass fraction during the first deployment days. This highlights the critical role of the interactions of polar analytes with POCIS sorbents and membranes in the performance of this method. Altogether, this study proposes a proof of concept for ME-CSIA of methoxychlor and its metabolites, opening the door for future investigations of their sources and transformation processes in contaminated sites.
Collapse
Affiliation(s)
- Martí Vinyes-Nadal
- Grup MAiMA, SGR Mineralogia Aplicada, Geoquímica i Hidrogeologia (MAGH), Departament de Mineralogia, Petrologia i Geologia Aplicada, Facultat de Ciències de la Terra, Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Martí i Franquès s/n, 08028 Barcelona, Spain.
| | - Jérémy Masbou
- Université de Strasbourg, CNRS/ENGEES, ITES UMR 7063, Institut Terre et Environnement de Strasbourg, Strasbourg, France.
| | - Steffen Kümmel
- Department of Technical Biogeochemistry, Helmholtz Centre for Environmental Research - UFZ, Permoserstraße 15, Leipzig 04318, Germany.
| | - Matthias Gehre
- Department of Technical Biogeochemistry, Helmholtz Centre for Environmental Research - UFZ, Permoserstraße 15, Leipzig 04318, Germany.
| | - Gwenaël Imfeld
- Université de Strasbourg, CNRS/ENGEES, ITES UMR 7063, Institut Terre et Environnement de Strasbourg, Strasbourg, France.
| | - Neus Otero
- Grup MAiMA, SGR Mineralogia Aplicada, Geoquímica i Hidrogeologia (MAGH), Departament de Mineralogia, Petrologia i Geologia Aplicada, Facultat de Ciències de la Terra, Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Martí i Franquès s/n, 08028 Barcelona, Spain; Serra Húnter Fellowship, Generalitat de Catalunya, Spain.
| | - Clara Torrentó
- Grup MAiMA, SGR Mineralogia Aplicada, Geoquímica i Hidrogeologia (MAGH), Departament de Mineralogia, Petrologia i Geologia Aplicada, Facultat de Ciències de la Terra, Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Martí i Franquès s/n, 08028 Barcelona, Spain; Serra Húnter Fellowship, Generalitat de Catalunya, Spain.
| |
Collapse
|
4
|
Mazzella N, Bernard M, Guibal R, Boutry S, Lissalde S, Guibaud G. Proposal of a new empirical model with flow velocity to improve time-weighted average concentration estimates from the Polar Organic Chemical Integrative Samplers. CHEMOSPHERE 2024; 350:141062. [PMID: 38159734 DOI: 10.1016/j.chemosphere.2023.141062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 12/20/2023] [Accepted: 12/27/2023] [Indexed: 01/03/2024]
Abstract
It is now widely recognized that the sampling rate of Polar Organic Chemical Integrative Samplers (POCIS) is significantly affected by flow velocity, which can cause a consequent bias when determining time-weighted average concentrations (TWAC). We already observed the desorption of deisopropylatrazine (DIA) over time when added to the receiving phase of a POCIS. This desorption rate was particularly influenced by flow velocity, in an agitated water environment in situ. In the method presented here, we calibrated 30 pesticides under controlled laboratory conditions, varying the flow velocity over four levels. We simultaneously studied the desorption rate of DIA-d5 (a deuterated form of DIA) over time. An empirical model based on a power law involving flow velocity was used to process the information from the accumulation kinetics of the compounds of interest and elimination of DIA-d5. This type of model makes it possible to consider the effect of this crucial factor on exchange kinetics, and then to obtain more accurate TWACs with reduced bias and more acceptable dispersion of results.
Collapse
Affiliation(s)
| | - Marion Bernard
- INRAE, UR EABX, 50 Avenue de Verdun, 33612 Cestas, France
| | - Robin Guibal
- Université de Limoges, E2Lim, 123 Avenue Albert Thomas, Limoges, Cedex 87060, France
| | | | - Sophie Lissalde
- Université de Limoges, E2Lim, 123 Avenue Albert Thomas, Limoges, Cedex 87060, France
| | - Gilles Guibaud
- Université de Limoges, E2Lim, 123 Avenue Albert Thomas, Limoges, Cedex 87060, France
| |
Collapse
|
5
|
Fialová P, Šverclová K, Grabicová K, Grabic R, Švecová H, Nováková P, Vrana B. Performance comparison of three passive samplers for monitoring of polar organic contaminants in treated municipal wastewater. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 908:168153. [PMID: 37914129 DOI: 10.1016/j.scitotenv.2023.168153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 10/24/2023] [Accepted: 10/25/2023] [Indexed: 11/03/2023]
Abstract
Over the past decades, several types of passive samplers have been developed and used to monitor polar organic compounds in aquatic environments. These samplers use different sorbents and barriers to control the uptake into the sampler, but their performance comparison is usually not well investigated. This study aimed to directly compare the performance of three samplers, i.e., the Polar Organic Chemical Integrative Sampler (POCIS), the Hydrogel-based Passive Sampler (HPS, an upscaled version of o-DGT), and the Speedisk, on a diverse suite of pharmaceuticals, per- and polyfluoroalkylated substances (PFAS), and pesticides and their metabolites. The samplers were deployed side-by-side in the treated effluent of a municipal wastewater treatment plant for different exposure times. All samplers accumulated a comparable number of compounds, and integrative uptake was observed for most compounds detected up to 28 days for POCIS, up to 14 days for HPS, and up to 42 days for Speedisk. In the integrative uptake phase, consistent surface-specific uptake was observed with a significant correlation between samplers (r ≥ 0.76) despite differences in sampler construction, diffusion barrier, and sorbent material used. The low sampling rates compared to the literature and the low estimated overall mass transfer coefficient suggests that the water boundary layer was the main barrier controlling the uptake for all samplers. Although all devices provided comparable performance, Speedisk overcomes POCIS and HPS in several criteria, including time-integrative sampling over a long period and physical durability.
Collapse
Affiliation(s)
- Pavla Fialová
- RECETOX, Faculty of Science, Masaryk University, Kotlářská 2, Brno 61137, Czech Republic; University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, 38925 Vodňany, Czech Republic
| | - Kateřina Šverclová
- RECETOX, Faculty of Science, Masaryk University, Kotlářská 2, Brno 61137, Czech Republic
| | - Kateřina Grabicová
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, 38925 Vodňany, Czech Republic
| | - Roman Grabic
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, 38925 Vodňany, Czech Republic
| | - Helena Švecová
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, 38925 Vodňany, Czech Republic
| | - Petra Nováková
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, 38925 Vodňany, Czech Republic
| | - Branislav Vrana
- RECETOX, Faculty of Science, Masaryk University, Kotlářská 2, Brno 61137, Czech Republic.
| |
Collapse
|
6
|
Tarábek P, Vrana B, Chalupková K, Bednáriková A, Okšová L, Bystrický P, Leonova N, Konovalova O. Examining the applicability of polar organic chemical integrative sampler for long-term monitoring of groundwater contamination caused by currently used pesticides. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 903:165905. [PMID: 37532041 DOI: 10.1016/j.scitotenv.2023.165905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 07/26/2023] [Accepted: 07/28/2023] [Indexed: 08/04/2023]
Abstract
The possibilities of expanding a groundwater quality monitoring scheme by passive sampling using polar organic chemical integrative sampler (POCIS) comprising HLB sorbent as the receiving phase were explored. Passive sampling and grab sampling were carried out simultaneously in the regions with vulnerable groundwater resources in Slovakia, between 2013 and 2021. For 27 pesticides and degradation products detected both in POCIS and the grab samples, in situ sampling rates were calculated and statistically evaluated. The limited effectiveness of the receiving phase in POCIS for sampling polar or ionized compounds was confirmed through a comparison of the medians of compound-specific sampling rates. For the majority of the monitored compounds the median sampling rates varied between 0.01 and 0.035 L/day. In some cases, the actual in situ values could be confirmed by parallel exposure of POCIS and silicone rubber sheet employed to obtain a benchmark for maximum attainable sampling rate. Sampling site and sampling period appear to have also some influence on the sampling rates, which was attributed in part to the groundwater velocity varying in both space and time. The influence of physico-chemical parameters (temperature, pH, electrolytic conductivity) remains mostly questionable due to the naturally limited ranges of recorded values over the entire duration of the study. Concentrations of pollutants in POCIS could be used for predicting time weighed average concentrations in water, provided the sampling rates were known and relatively constant. Generally, the compound-specific sampling rate cannot be considered constant due to a combination of naturally varying environmental factors that influence the actual in situ sampling rate. The relative standard deviation of concentration data from POCIS exposed in triplicates varied between approx. 5 %-50 %. Utilizing exploratory data analysis approach and tools enabled us to obtain a relatively complex picture of the situation and progress regarding pesticide pollution of groundwater in the monitored areas.
Collapse
Affiliation(s)
- Peter Tarábek
- Water Research Institute, Nábr. arm. gen. L. Svobodu 5, 81249 Bratislava, Slovakia.
| | - Branislav Vrana
- RECETOX, Faculty of Science, Masaryk University, Kotlářská 2, 61137 Brno, Czech Republic
| | - Katarína Chalupková
- Water Research Institute, Nábr. arm. gen. L. Svobodu 5, 81249 Bratislava, Slovakia
| | - Alena Bednáriková
- Water Research Institute, Nábr. arm. gen. L. Svobodu 5, 81249 Bratislava, Slovakia
| | - Linda Okšová
- Water Research Institute, Nábr. arm. gen. L. Svobodu 5, 81249 Bratislava, Slovakia
| | - Peter Bystrický
- Water Research Institute, Nábr. arm. gen. L. Svobodu 5, 81249 Bratislava, Slovakia
| | - Nataliia Leonova
- Water Research Institute, Nábr. arm. gen. L. Svobodu 5, 81249 Bratislava, Slovakia
| | - Olga Konovalova
- Water Research Institute, Nábr. arm. gen. L. Svobodu 5, 81249 Bratislava, Slovakia
| |
Collapse
|
7
|
Martins de Barros R, Lissalde S, Guibal R, Guibaud G. Adaptation of the o-DGT for the sampling of 12 hormones: calibration, performance evaluation, and recommendation. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:68177-68190. [PMID: 37119483 DOI: 10.1007/s11356-023-26975-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Accepted: 04/09/2023] [Indexed: 05/27/2023]
Abstract
This work highlights the methodology for the development of diffusive gradients in thin films (o-DGT) through its adaptation for 12 natural and synthetic hormones belonging to three different families (estrogens, progestins, and androgens). A reliable strategy must be applied during o-DGT lab adaptation to avoid issues related to the analysis (i.e., presence of matrix effects in grab or passive samples) but also to the o-DGT configuration (i.e., undesirable sorption or desorption, lack of performance with insufficient elution or unreliable diffusion coefficient). To avoid analytical issues due to the presence of salts in grab samples, CaCl2 exposure solutions must be used on a lab-scale development to monitor the hormone concentration. The selected o-DGT was composed of an Oasis® HLB binding gel and a diffusive gel in agarose because they provided better performance than polyacrylamide gels (i.e., higher elution factors and more repeatable diffusion coefficients). The elution factors of the binding gel were then from 0.79 ± 0.13 to 1.04 ± 0.13 (RSD < 15%) and the diffusion coefficients at 25 °C were from 4.07 ± 0.24 to 5.49 ± 0.28 × 10-6 cm2 s-1 (RSD < 9%). A laboratory exposure to a synthetic solution was performed to check the consistency with the DGT quantification model validating the calibration parameters for all hormones (except 17α-ethinylestradiol with a bias of 40%). Therefore, the o-DGT configuration is suitable for sampling hormones in the natural environment with LOQDGT ranging from 0.3 to 6.6 ng L-1.
Collapse
Affiliation(s)
| | - Sophie Lissalde
- University of Limoges, E2Lim, 123 Avenue Albert Thomas, 87060, Limoges Cedex, France.
| | - Robin Guibal
- University of Limoges, E2Lim, ENSIL-ENSCI, 16 Rue Atlantis, 87068, Limoges Cedex, France
| | - Gilles Guibaud
- University of Limoges, E2Lim, 123 Avenue Albert Thomas, 87060, Limoges Cedex, France
| |
Collapse
|
8
|
Clokey JE, Hawker DW, Verhagen R, Ghorbani Gorji S, Knight ER, Thomas KV, Kaserzon SL. Calibration of a microporous polyethylene tube passive sampler for polar organic compounds in wastewater effluent. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 874:162497. [PMID: 36863593 DOI: 10.1016/j.scitotenv.2023.162497] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 02/20/2023] [Accepted: 02/23/2023] [Indexed: 06/18/2023]
Abstract
Water resources are vulnerable to contamination from polar organic compounds (POCs) originating from sources such as wastewater effluent. Two configurations of a microporous polyethylene tube (MPT) passive sampler were investigated for the time-integrative detection and quantification of POCs in effluent. One configuration contained the polymeric reversed phase sorbent Strata-X (SX) and the other Strata-X suspended in agarose gel (SX-Gel). These were deployed for up to 29 days and analysed for forty-nine POCs including pesticides, pharmaceuticals and personal care products (PPCPs) together with illicit drugs. Complementary composite samples were collected on days 6, 12, 20 and 26 representing the previous 24 h. Thirty-eight contaminants were detected in composite samples and MPT extracts, with MPT sampling rates (Rs) for 11 pesticides and 9 PPCPs/drugs ranging from 0.81 to 10.32 mL d-1 in SX and 1.35-32.83 mL d-1 in SX-Gel. Half-times to equilibrium of contaminants with the SX and SX-Gel equipped samplers ranged from two days to >29 days. MPT (SX) samplers were also deployed at 10 wastewater treatment effluent discharge sites across Australia for 7 days (again with complementary composite samples), to validate the sampler performance under varying conditions. Extracts from these MPTs detected 48 contaminants in comparison with 46 in composite samples, with concentrations ranging from 0.1 to 138 ng mL-1. An advantage of the MPT was preconcentration of contaminants, resulting in extract levels often markedly above instrument analytical detection limits. The validation study demonstrated a high correlation between accumulated contaminant mass in the MPTs and wastewater concentrations from composite samples (r2 > 0.70, where concentrations in composite samples were > 3× LOD). The MPT sampler shows promise as a sensitive tool for detecting POCs at trace levels in wastewater effluent and also quantifying these levels if temporal concentration variations are not significant.
Collapse
Affiliation(s)
- Joseph E Clokey
- The University of Queensland, Queensland Alliance for Environmental Health Sciences (QAEHS), 20 Cornwall Street, Woolloongabba, QLD 4102, Australia.
| | - Darryl W Hawker
- Griffith University, School of Environment and Science, 170 Kessels Road, Nathan, QLD 4111, Australia
| | - Rory Verhagen
- The University of Queensland, Queensland Alliance for Environmental Health Sciences (QAEHS), 20 Cornwall Street, Woolloongabba, QLD 4102, Australia
| | - Sara Ghorbani Gorji
- The University of Queensland, Queensland Alliance for Environmental Health Sciences (QAEHS), 20 Cornwall Street, Woolloongabba, QLD 4102, Australia
| | - Emma R Knight
- The University of Queensland, Queensland Alliance for Environmental Health Sciences (QAEHS), 20 Cornwall Street, Woolloongabba, QLD 4102, Australia
| | - Kevin V Thomas
- The University of Queensland, Queensland Alliance for Environmental Health Sciences (QAEHS), 20 Cornwall Street, Woolloongabba, QLD 4102, Australia
| | - Sarit L Kaserzon
- The University of Queensland, Queensland Alliance for Environmental Health Sciences (QAEHS), 20 Cornwall Street, Woolloongabba, QLD 4102, Australia
| |
Collapse
|
9
|
Glanzmann V, Reymond N, Weyermann C, Estoppey N. An improved Chemcatcher-based method for the integrative passive sampling of 44 hydrophilic micropollutants in surface water - Part A: Calibration under four controlled hydrodynamic conditions. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 871:162037. [PMID: 36740052 DOI: 10.1016/j.scitotenv.2023.162037] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 01/14/2023] [Accepted: 02/01/2023] [Indexed: 06/18/2023]
Abstract
When monitoring water quality with hydrophilic integrative passive sampling devices, it is crucial to use accurate sampling rates (RS) that account for exposure conditions such as hydrodynamics. This study aims at calibrating Chemcatcher-like passive samplers - styrene-divinylbenzene reverse phase sulfonate (SDB-RPS) extraction disk covered by a polyethersulfone (PES) membrane - at four water flow velocities (5 to 40 cm s-1) in a channel system. First, the four hydrodynamic conditions were characterized by measuring the mass transfer coefficients of the water boundary layer (kw) at the surface of the samplers using the alabaster dissolution method. Then, fifty-six samplers were deployed in the channels and exposed for 7 different intervals varying from 1 to 21 days. Thus, RS were determined at four different kw for 44 hydrophilic compounds, ranging from 0.015 to 0.115 L day-1. Relationships were established between kw and RS using models for mixed rate control by the membrane and the water boundary layer. The estimated parameters of those relationships are suitable for the determination of accurate RS when kw is measured in situ, for example by co-deploying silicone disks spiked with performance and reference compounds (PRC) as implemented in Part B.
Collapse
Affiliation(s)
- Vick Glanzmann
- School of Criminal Justice, University of Lausanne, Batochime building, 1015 Lausanne, Switzerland.
| | - Naomi Reymond
- School of Criminal Justice, University of Lausanne, Batochime building, 1015 Lausanne, Switzerland
| | - Céline Weyermann
- School of Criminal Justice, University of Lausanne, Batochime building, 1015 Lausanne, Switzerland.
| | - Nicolas Estoppey
- School of Criminal Justice, University of Lausanne, Batochime building, 1015 Lausanne, Switzerland; Norwegian Geotechnical Institute (NGI), P.O. Box. 3930 Ullevål Stadion, N-0806 Oslo, Norway
| |
Collapse
|
10
|
Dunn M, Becanova J, Snook J, Ruyle B, Lohmann R. Calibration of Perfluorinated Alkyl Acid Uptake Rates by a Tube Passive Sampler in Water. ACS ES&T WATER 2023; 3:332-341. [PMID: 37006340 PMCID: PMC10062324 DOI: 10.1021/acsestwater.2c00384] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Abstract
Per- and polyfluoroalkyl substances (PFAS) are a group of 4000+ man-made compounds of great concern due to their environmental ubiquity and adverse effects. Despite a general interest, few reliable detection tools for integrative passive sampling of PFAS in water are available. A microporous polyethylene tube with a hydrophilic-lipophilic balance sorbent could serve as a flow-resistant passive sampler for PFAS. The tube's sampling rate, Rs, was predicted based on either partitioning and diffusion, or solely diffusion. At 15 °C, the laboratory measured Rs for perfluorohexanoic acid of 100+/-81 mL day-1 were better predicted by a partitioning and diffusion model (48+/-1.8 mL day-1) across 10-60 cm s-1 water flow speeds (15+/-4.2 mL day-1 diffusion only). For perfluorohexane sulfonate, Rs at 15°C were similarly different (110+/-60 mL day-1 measured, 120+/- 63 versus 12+/-3.4 mL day-1 in respective models). Rs values from field deployments were in-between these estimates (46 +/-40 mL day-1 for perfluorohexanoic acid). PFAS uptake was not different for previously biofouled membranes in the laboratory, suggesting the general applicability of the sampler in environmental conditions. This research demonstrates that the polyethylene tube's sampling rates are sensitive to the parameterization of the models used here and partitioning-derived values should be used.
Collapse
Affiliation(s)
- Matt Dunn
- Graduate School of Oceanography, University of Rhode Island, 215 South Ferry Rd, Narragansett, 02882 RI, USA
| | - Jitka Becanova
- Graduate School of Oceanography, University of Rhode Island, 215 South Ferry Rd, Narragansett, 02882 RI, USA
| | - Jarod Snook
- Graduate School of Oceanography, University of Rhode Island, 215 South Ferry Rd, Narragansett, 02882 RI, USA
| | - Bridger Ruyle
- Harvard John A. Paulson School of Engineering and Applied Science, Harvard University, Cambridge, MA, USA
| | - Rainer Lohmann
- Graduate School of Oceanography, University of Rhode Island, 215 South Ferry Rd, Narragansett, 02882 RI, USA
| |
Collapse
|
11
|
MacKeown H, Benedetti B, Scapuzzi C, Di Carro M, Magi E. A Review on Polyethersulfone Membranes in Polar Organic Chemical Integrative Samplers: Preparation, Characterization and Innovation. Crit Rev Anal Chem 2022:1-17. [PMID: 36263980 DOI: 10.1080/10408347.2022.2131374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
The membranes in polar organic chemical integrative samplers (POCIS) enclose the receiving sorbent and protect it from coming into direct contact with the environmental matrix. They have a crucial role in extending the kinetic regime of contaminant uptake, by slowing down their diffusion between the water phase and the receiving phase. The drive to improve passive sampling requires membranes with better design and enhanced performances. In this review, the preparation of standard polyethersulfone (PES) membranes for POCIS is presented, as well as methods to evaluate their composition, morphology, structure, and performance. Generally, only supplier-related morphological and structural data are provided, such as membrane type, thickness, surface area, and pore diameter. The issues related to the use of PES membranes in POCIS applications are exposed. Finally, alternative membranes to PES in POCIS are also discussed, although no better membrane has yet been developed. This review highlights the urge for more membrane characterization details and a better comprehension of the mechanisms which underlay their behavior and performance, to improve membrane selection and optimize passive sampler development.
Collapse
Affiliation(s)
- Henry MacKeown
- Department of Chemistry and Industrial Chemistry, University of Genoa, Genoa, Italy
| | - Barbara Benedetti
- Department of Chemistry and Industrial Chemistry, University of Genoa, Genoa, Italy
| | - Chiara Scapuzzi
- Department of Chemistry and Industrial Chemistry, University of Genoa, Genoa, Italy
| | - Marina Di Carro
- Department of Chemistry and Industrial Chemistry, University of Genoa, Genoa, Italy
| | - Emanuele Magi
- Department of Chemistry and Industrial Chemistry, University of Genoa, Genoa, Italy
| |
Collapse
|
12
|
Khulu S, Ncube S, Nuapia Y, Madikizela LM, Mavhunga E, Chimuka L. Development and application of a membrane assisted solvent extraction-molecularly imprinted polymer based passive sampler for monitoring of selected pharmaceuticals in surface water. WATER RESEARCH 2022; 225:119145. [PMID: 36179429 DOI: 10.1016/j.watres.2022.119145] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 09/20/2022] [Accepted: 09/21/2022] [Indexed: 06/16/2023]
Abstract
In this work, we demonstrate the development, evaluation and pre-liminary application of a novel passive sampler for monitoring of selected pharmaceuticals in environmental waters. The samplers were calibrated in laboratory-based experiments to obtain sampling rates (Rs) for carbamazepine, methocarbamol, etilefrine, venlafaxine and nevirapine. Passive sampling was based on the diffusion of the target pharmaceuticals from surface water through a membrane bag which housed an ionic liquid as a green receiving solvent and a molecularly imprinted polymer. Effects of biofouling, deployment time and solvent type for the receiver phase were optimized for selective uptake of analytes in surface water. Notably, there was a decrease in the uptake of selected pharmaceuticals and consequently a decrease in their sampling rates in the presence of biofouling. The optimum matrix-matched sampling rates ranged from 0.0007 - 0.0018 L d-1 whilst the method detection and quantification limits ranged from 2.45 - 3.26 ng L-1 and 8.06 - 10.81 ng L-1, respectively. The optimized passive sampler was deployed in a dam situated in the heart of a typical highly populated township in the Gauteng Province of South Africa. Only etilefrine and methocarbamol were detected and quantified at maximum time weighted average concentrations of 12.88 and 72.29 ng L-1, respectively.
Collapse
Affiliation(s)
- Sinegugu Khulu
- Molecular Sciences Institute, University of Witwatersrand, Private Bag X3, Johannesburg, 2050, South Africa; School of Education, University of Witwatersrand, Private Bag X3, Johannesburg, 2050, South Africa
| | - Somandla Ncube
- Department of Chemistry, Sefako Makgatho Health Sciences University, P.O Box 60, Medunsa, 0204, South Africa
| | - Yannick Nuapia
- Molecular Sciences Institute, University of Witwatersrand, Private Bag X3, Johannesburg, 2050, South Africa; Pharmacy Department, School of Health Sciences, University of Limpopo, Turfloop Campus, Polokwane, 0727, South Africa
| | - Lawrence Mzukisi Madikizela
- Molecular Sciences Institute, University of Witwatersrand, Private Bag X3, Johannesburg, 2050, South Africa; Institute for Nanotechnology and Water Sustainability, College of Science, Engineering and Technology, University of South Africa, Florida Science Campus, 1710, South Africa
| | - Elizabeth Mavhunga
- School of Education, University of Witwatersrand, Private Bag X3, Johannesburg, 2050, South Africa
| | - Luke Chimuka
- Molecular Sciences Institute, University of Witwatersrand, Private Bag X3, Johannesburg, 2050, South Africa.
| |
Collapse
|
13
|
Coble AA, Silva-Sanchez C, Arthurs WJ, Flinders CA. Detection and accumulation of environmentally-relevant glyphosate concentrations delivered via pulse- or continuous-delivery on passive samplers. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 838:156131. [PMID: 35605867 DOI: 10.1016/j.scitotenv.2022.156131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 05/17/2022] [Accepted: 05/17/2022] [Indexed: 06/15/2023]
Abstract
Glyphosate is the most commonly used herbicide globally, which has contributed to its ubiquitous presence in the environment. Glyphosate application rates and delivery to surface water vary with land use. Streams in urban and agricultural catchments can experience continuous delivery of low concentrations of glyphosate and aminomethylphosphonic acid (AMPA), while their presence in forest streams occurs as an episodic pulse following silvicultural application. We assessed whether trace concentrations of glyphosate delivered as a 1-day pulse (mimic silvicultural applications) followed by flushing with deionized water would affect the detection of glyphosate or AMPA on novel passive samplers, Polar Organic Chemical Integrative Sampler with Molecular Imprinted Polymer (POCIS-MIP), compared with continuous delivery (mimic agricultural or urban applications). Within each delivery type, POCIS-MIP were exposed to seven treatment concentrations of Rodeo (equivalent to 0.0 to 1.84 μg glyphosate L-1). Experimental results demonstrate POCIS-MIP can detect differences in relative glyphosate concentrations above 0.115 μg L-1 (pulse-delivery) or 0.23 μg L-1 (continuous-delivery), but were unable to distinguish trace concentrations (i.e., < 0.115 or 0.23 μg L-1). Our results suggest POCIS-MIP may better retain glyphosate when delivered as a pulse than when delivered continuously, but both underestimated actual treatment concentrations by 46 to 56%. There is a need to demonstrate the field applicability of passive sampling methods to improve environmental monitoring of silvicultural herbicides, and our results demonstrate passive samplers were unable to distinguish lower concentrations, suggesting a limited utility for determining trace concentration levels such as those experienced during or immediately after silvicultural application.
Collapse
Affiliation(s)
- Ashley A Coble
- NCASI, 2438 NW Professional Drive, Corvallis, OR 97330, United States of America.
| | | | - William J Arthurs
- NCASI, 1117 3rd Street, Anacortes, WA 98221, United States of America
| | | |
Collapse
|
14
|
Glanzmann V, Booij K, Reymond N, Weyermann C, Estoppey N. Determining the Mass Transfer Coefficient of the Water Boundary Layer at the Surface of Aquatic Integrative Passive Samplers. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:6391-6398. [PMID: 35420785 DOI: 10.1021/acs.est.1c08088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Passive sampling devices (PSDs) offer key benefits for monitoring chemical water quality, but the uptake process of PSDs for hydrophilic compounds still needs to be better understood. Determining mass transfer coefficients of the water boundary layer (kw) during calibration experiments and in situ monitoring would contribute toward achieving this; it allows for combining calibration data obtained at different temperature and hydrodynamic conditions and facilitate the translation of laboratory-derived calibration data to field exposure. This study compared two kw measurement methods applied to extraction disk housings (Chemcatcher), namely, alabaster dissolution and dissipation of performance reference compounds (PRCs) from silicone. Alabaster- and PRC-based kw were measured at four flow velocities (5-40 cm s-1) and two temperatures (11 and 20 °C) in a channel system. Data were compared using a relationship based on Sherwood, Reynolds, and Schmidt numbers. Good agreement was observed between data obtained at both temperatures, and for the two methods. Data were well explained by a model for mass transfer to a flat plate under laminar flow. It was slightly adapted to provide a semi-empirical model accounting for the effects of housing design on hydrodynamics. The use of PRC-spiked silicone to obtain in situ integrative kw for Chemcatcher-type PSDs is also discussed.
Collapse
Affiliation(s)
- Vick Glanzmann
- School of Criminal Justice, University of Lausanne, Batochime building, 1015 Lausanne, Switzerland
| | - Kees Booij
- PaSOC, Greate Pierwei 25, 8821 LV Kimswerd, The Netherlands
| | - Naomi Reymond
- School of Criminal Justice, University of Lausanne, Batochime building, 1015 Lausanne, Switzerland
| | - Céline Weyermann
- School of Criminal Justice, University of Lausanne, Batochime building, 1015 Lausanne, Switzerland
| | - Nicolas Estoppey
- School of Criminal Justice, University of Lausanne, Batochime building, 1015 Lausanne, Switzerland
| |
Collapse
|
15
|
De María M, Silva-Sanchez C, Kroll KJ, Walsh MT, Nouri MZ, Hunter ME, Ross M, Clauss TM, Denslow ND. Chronic exposure to glyphosate in Florida manatee. ENVIRONMENT INTERNATIONAL 2021; 152:106493. [PMID: 33740675 DOI: 10.1016/j.envint.2021.106493] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 02/24/2021] [Accepted: 02/26/2021] [Indexed: 05/25/2023]
Abstract
Florida manatees depend on freshwater environments as a source of drinking water and as warm-water refuges. These freshwater environments are in direct contact with human activities where glyphosate-based herbicides are being used. Glyphosate is the most used herbicide worldwide and it is intensively used in Florida as a sugarcane ripener and to control invasive aquatic plants. The objective of the present study was to determine the concentration of glyphosate and its breakdown product, aminomethylphosphonic acid (AMPA), in Florida manatee plasma and assess their exposure to manatees seeking a warm-water refuge in Crystal River (west central Florida), and in South Florida. We analyzed glyphosate's and AMPA's concentrations in Florida manatee plasma (n = 105) collected during 2009-2019 using HPLC-MS/MS. We sampled eight Florida water bodies between 2019 and 2020, three times a year: before, during and after the sugarcane harvest using grab samples and molecular imprinted passive Polar Organic Chemical Integrative Samplers (MIP-POCIS). Glyphosate was present in 55.8% of the sampled Florida manatees' plasma. The concentration of glyphosate has significantly increased in Florida manatee samples from 2009 until 2019. Glyphosate and AMPA were ubiquitous in water bodies. The concentration of glyphosate and AMPA was higher in South Florida than in Crystal River, particularly before and during the sugarcane harvest when Florida manatees depend on warm water refuges. Based on our results, Florida manatees were chronically exposed to glyphosate and AMPA, during and beyond the glyphosate applications to sugarcane, possibly associated with multiple uses of glyphosate-based herbicides for other crops or to control aquatic weeds. This chronic exposure in Florida water bodies may have consequences for Florida manatees' immune and renal systems which may further be compounded by other environmental exposures such as red tide or cold stress.
Collapse
Affiliation(s)
- Maite De María
- Department of Physiological Sciences and Center for Environmental and Human Toxicology, University of Florida, Gainesville, FL 32611, USA; Aquatic Animal Health Program, College of Veterinary Medicine, University of Florida, PO Box 100136, Gainesville, FL 32610, USA.
| | - Cecilia Silva-Sanchez
- Department of Physiological Sciences and Center for Environmental and Human Toxicology, University of Florida, Gainesville, FL 32611, USA.
| | - Kevin J Kroll
- Department of Physiological Sciences and Center for Environmental and Human Toxicology, University of Florida, Gainesville, FL 32611, USA.
| | - Michael T Walsh
- Aquatic Animal Health Program, College of Veterinary Medicine, University of Florida, PO Box 100136, Gainesville, FL 32610, USA.
| | - Mohammad-Zaman Nouri
- Department of Physiological Sciences and Center for Environmental and Human Toxicology, University of Florida, Gainesville, FL 32611, USA.
| | - Margaret E Hunter
- U.S. Geological Survey, Wetland and Aquatic Research Center, Gainesville, FL 32653, United States.
| | - Monica Ross
- Clearwater Marine Aquarium, 249 Windward Passage, Clearwater, FL 33767, USA.
| | - Tonya M Clauss
- Georgia Aquarium, Atlanta, Georgia, 225 Baker Street Northwest, Atlanta, GA 30313, USA.
| | - Nancy D Denslow
- Department of Physiological Sciences and Center for Environmental and Human Toxicology, University of Florida, Gainesville, FL 32611, USA; Department of Biochemistry and Molecular Biology, University of Florida, Gainesville, FL 32610, USA.
| |
Collapse
|
16
|
Godlewska K, Jakubus A, Stepnowski P, Paszkiewicz M. Impact of environmental factors on the sampling rate of β-blockers and sulfonamides from water by a carbon nanotube-passive sampler. J Environ Sci (China) 2021; 101:413-427. [PMID: 33334535 DOI: 10.1016/j.jes.2020.08.034] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 08/31/2020] [Accepted: 08/31/2020] [Indexed: 06/12/2023]
Abstract
Passive techniques are a constantly evolving approach to the long-term monitoring of micropollutants, including pharmaceuticals, in the aquatic environment. This paper presents, for the first time, the calibration results of a new CNTs-PSDs (carbon nanotubes used as a sorbent in passive sampling devices) with an examination of the effect of donor phase salinity, water pH and the concentration of dissolved humic acids (DHAs), using both ultrapure and environmental waters. Sampling rates (Rs) were determined for the developed kinetic samplers. It has been observed that the impact of the examined environmental factors on the Rs values strictly depends on the type of the analytes. In the case of β-blockers, the only environmental parameter affecting their uptake rate was the salinity of water. A certain relationship was noted, namely the higher the salt concentration in water, the lower the Rs values of β-blockers. In the case of sulfonamides, water salinity, water pH 7-9 and DHAs concentration decreased the uptake rate of these compounds by CNTs-PSDs. The determined Rs values differed in particular when the values obtained from the experiments carried out using ultrapure water and environmental waters were compared. The general conclusion is that the calibration of novel CNTs-PSDs should be carried out under physicochemical conditions of the aquatic phase that are similar to the environmental matrix.
Collapse
Affiliation(s)
- Klaudia Godlewska
- Department of Environmental Analysis, Faculty of Chemistry, University of Gdansk, ul. Wita Stwosza 63, Gdansk 80-308, Poland.
| | - Aleksandra Jakubus
- Department of Environmental Analysis, Faculty of Chemistry, University of Gdansk, ul. Wita Stwosza 63, Gdansk 80-308, Poland
| | - Piotr Stepnowski
- Department of Environmental Analysis, Faculty of Chemistry, University of Gdansk, ul. Wita Stwosza 63, Gdansk 80-308, Poland
| | - Monika Paszkiewicz
- Department of Environmental Analysis, Faculty of Chemistry, University of Gdansk, ul. Wita Stwosza 63, Gdansk 80-308, Poland
| |
Collapse
|
17
|
Vrana B, Urík J, Fedorova G, Švecová H, Grabicová K, Golovko O, Randák T, Grabic R. In situ calibration of polar organic chemical integrative sampler (POCIS) for monitoring of pharmaceuticals in surface waters. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2021; 269:116121. [PMID: 33272798 DOI: 10.1016/j.envpol.2020.116121] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Revised: 11/14/2020] [Accepted: 11/16/2020] [Indexed: 06/12/2023]
Abstract
POCIS is the most widely applied passive sampler of polar organic substances, because it was one of the first commercially available samplers for that purpose on the market, but also for its applicability for a wide range of substances and conditions. Its main weakness is the variability of sampling performance with exposure conditions. In our study we took a pragmatic approach and performed in situ calibration for a set of 76 pharmaceuticals and their metabolites in five sampling campaigns in surface water, covering various temperature and flow conditions. In individual campaigns, RS were calculated for up to 47 compounds ranging from 0.01 to 0.63 L d-1, with the overall median value of 0.10 L d-1. No clear changes of RS with water temperature or discharge could be found for any of the investigated substances. The absence of correlation of experimental RS with physical-chemical properties in combination with the lack of mechanistic understanding of compound uptake to POCIS implies that practical estimation of aqueous concentrations from uptake in POCIS depends on compound-specific experimental calibration data. Performance of POCIS was compared with grab sampling of water in seven field campaigns comprising multiple sampling sites, where sampling by both methods was done in parallel. The comparison showed that for 25 of 36 tested compounds more than 50% of POCIS-derived aqueous concentrations did not differ from median of grab sampling values more than by a factor of 2. Further, for 30 of 36 compounds, more than 80% of POCIS data did not differ from grab sampling data more than by a factor of 5. When accepting this level of accuracy, in situ derived sampling rates are sufficiently robust for application of POCIS for identification of spatial and temporal contamination trends in surface waters.
Collapse
Affiliation(s)
- Branislav Vrana
- Masaryk University, Faculty of Science, Centre RECETOX, Kamenice 753/5, 625 00, Brno, Czech Republic.
| | - Jakub Urík
- Masaryk University, Faculty of Science, Centre RECETOX, Kamenice 753/5, 625 00, Brno, Czech Republic
| | - Ganna Fedorova
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, CZ-389 25, Vodňany, Czech Republic
| | - Helena Švecová
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, CZ-389 25, Vodňany, Czech Republic
| | - Kateřina Grabicová
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, CZ-389 25, Vodňany, Czech Republic
| | - Oksana Golovko
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, CZ-389 25, Vodňany, Czech Republic
| | - Tomáš Randák
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, CZ-389 25, Vodňany, Czech Republic
| | - Roman Grabic
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, CZ-389 25, Vodňany, Czech Republic
| |
Collapse
|
18
|
Wang P, Challis JK, Luong KH, Vera TC, Wong CS. Calibration of organic-diffusive gradients in thin films (o-DGT) passive samplers for perfluorinated alkyl acids in water. CHEMOSPHERE 2021; 263:128325. [PMID: 33297256 DOI: 10.1016/j.chemosphere.2020.128325] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 09/08/2020] [Accepted: 09/10/2020] [Indexed: 06/12/2023]
Abstract
The application of the organic-diffusive gradients in thin films (o-DGT) passive sampling technique for the monitoring of per- and polyfluoroalkyl substances (PFAS) in the environment is still limited. Six common PFAS with different chain lengths were evaluated in water by o-DGT. Measured diffusion coefficients (D) in agarose and polyacrylamide diffusive gels ranged from 4.55-8.63 × 10-6 cm2 s-1 and 3.85-7.00 × 10-6 cm2 s-1 at 23 °C, respectively. Experimental sampling rates (Rs) for both agarose- and polyacrylamide-WAX sampler configurations were within 22% relative error of D-based Rs for four of the PFAS. Larger differences for perfluorobutanesulfonic acid (PFBS) and perfluoroundecanoic acid (PFUnDA) ranged from 36% to 56%. In general, in-situ Rs can be predicted using measured D-values for perfluorinated alkyl acids. The mass accumulation of six PFAS in two o-DGT configurations was linear over 21 days (R2 ≥ 0.97). Diffusion and uptake of o-DGT depended on the gel type and specific PFAS. Field demonstrations of o-DGT with WAX and HLB binding gels and polyacrylamide diffusive gels (not prone to biodegradation) found 0.3-19.5 ng L-1 of PFAS in rivers near industrial areas around Guangzhou and Foshan, China, with no apparent differences between the two co-deployed samplers. This study demonstrates that the configurations of o-DGT tested provide a cost-effective monitoring tool for measuring perfluorinated alkyl acids in aquatic systems, in particular the four PFAS for which reasonable correlations were observed.
Collapse
Affiliation(s)
- Po Wang
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou, 510632, China; Southern California Coastal Water Research Project Authority, Costa Mesa, CA, 92626, USA
| | - Jonathan K Challis
- Toxicology Centre, University of Saskatchewan, Saskatoon, SK, S7N 5B3, Canada
| | - Kim H Luong
- Richardson College for the Environment, University of Winnipeg, Winnipeg, Manitoba, R3B 2E9, Canada
| | - Trisha C Vera
- Richardson College for the Environment, University of Winnipeg, Winnipeg, Manitoba, R3B 2E9, Canada
| | - Charles S Wong
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou, 510632, China; Southern California Coastal Water Research Project Authority, Costa Mesa, CA, 92626, USA; Richardson College for the Environment, University of Winnipeg, Winnipeg, Manitoba, R3B 2E9, Canada.
| |
Collapse
|
19
|
Schreiner VC, Bakanov N, Kattwinkel M, Könemann S, Kunz S, Vermeirssen ELM, Schäfer RB. Sampling rates for passive samplers exposed to a field-relevant peak of 42 organic pesticides. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 740:140376. [PMID: 32927560 DOI: 10.1016/j.scitotenv.2020.140376] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 06/17/2020] [Accepted: 06/18/2020] [Indexed: 06/11/2023]
Abstract
Pesticide concentrations in agricultural streams are often characterised by a low level of baseline exposure and episodic peak concentrations associated with heavy rainfall events. Traditional sampling methods such as grab sampling, which are still largely used in governmental monitoring, typically miss peak concentrations. Passive sampling represents a cost-efficient alternative but requires the additional determination of sampling rates to calculate time-weighted average (TWA) water concentrations from the accumulated pesticide mass in the sampler. To date, sampling rates have largely been determined in experiments with constant exposure, which does not necessarily reflect field situations. Using Empore styrene-divinylbenzene (SDB) passive sampler disks mounted in metal holders, we determined sampling rates for 42 organic pesticides, of which 27 sampling rates were lacking before. The SDB disks were in an artificial channel system exposed to a field-relevant pesticide peak. We used an open-source algorithm to estimate coefficients of equations for the accumulated pesticide mass in disks and to determine exposure time-dependent sampling rates. These sampling rates ranged from 0.02 to 0.98 L d-1 and corresponded to those from previous studies determined with constant exposure. The prediction of sampling rates using compound properties was unreliable. Hence, experiments are required to determine reliable sampling rates. We discuss the use of passive sampling to estimate peak concentrations. Overall, our study provides sampling rates and computer code to determine these under peak exposure designs and suggests that passive sampling is suitable to estimate peak pesticide concentrations in field studies.
Collapse
Affiliation(s)
- Verena C Schreiner
- iES Landau, Institute for Environmental Sciences, University Koblenz-Landau, Fortstraße 7, 76829 Landau in der Pfalz, Germany.
| | - Nikita Bakanov
- iES Landau, Institute for Environmental Sciences, University Koblenz-Landau, Fortstraße 7, 76829 Landau in der Pfalz, Germany
| | - Mira Kattwinkel
- iES Landau, Institute for Environmental Sciences, University Koblenz-Landau, Fortstraße 7, 76829 Landau in der Pfalz, Germany
| | - Sarah Könemann
- Swiss Centre for Applied Ecotoxicology, 8600 Dübendorf, Switzerland
| | - Stefan Kunz
- iES Landau, Institute for Environmental Sciences, University Koblenz-Landau, Fortstraße 7, 76829 Landau in der Pfalz, Germany
| | | | - Ralf B Schäfer
- iES Landau, Institute for Environmental Sciences, University Koblenz-Landau, Fortstraße 7, 76829 Landau in der Pfalz, Germany
| |
Collapse
|
20
|
Booij K, Chen S, Trask JR. POCIS Calibration for Organic Compound Sampling in Small Headwater Streams. ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY 2020; 39:1334-1342. [PMID: 32408378 DOI: 10.1002/etc.4731] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Revised: 03/23/2020] [Accepted: 04/21/2020] [Indexed: 06/11/2023]
Abstract
Field-based atrazine sampling rates (Rs ) obtained by the polar organic chemical integrative sampler (POCIS) method were measured in 9 headwater streams over 3 yr covering 5 to 6 exposure periods of 2 to 3 wk/site/yr. Rates were best in line with the model Rs = 148 mL/d, with a standard deviation of 0.17 log units (factor 1.5). The POCIS canisters reduced mass transfer coefficients of the water boundary layer by a factor of 2 as measured by alabaster dissolution rates. A mechanistic model that accounts for flow and temperature effects yielded a fair estimate of the effective exchange surface area (12.5 ± 0.8 cm2 ). This model could only be tested for higher flow velocities because of uncertainties associated with the measurement of flow velocities <1 cm/s. Pictures of sorbent distributions in POCIS devices showed that the effective exchange surface area varied with time during the exposures. Error analysis indicated that sorbent distributions and chemical analysis were minor error sources. Our main conclusion is that an atrazine sampling rate of 148 mL/d yielded consistent results for all 3 yr across 9 headwater streams. Environ Toxicol Chem 2020;39:1334-1342. © 2020 SETAC.
Collapse
Affiliation(s)
- Kees Booij
- Passive Sampling of Organic Compounds (PaSOC), Kimswerd, The Netherlands
| | - Sunmao Chen
- Syngenta Crop Protection, Greensboro, North Carolina, USA
| | | |
Collapse
|
21
|
Challis JK, Almirall XO, Helm PA, Wong CS. Performance of the organic-diffusive gradients in thin-films passive sampler for measurement of target and suspect wastewater contaminants. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2020; 261:114092. [PMID: 32059137 DOI: 10.1016/j.envpol.2020.114092] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Revised: 01/22/2020] [Accepted: 01/27/2020] [Indexed: 06/10/2023]
Abstract
Although passive sampling is widely accepted as an excellent tool for environmental monitoring, their integration with suspect or non-targeted screening by high-resolution mass spectrometry has been limited. This study describes the application of the organic-diffusive gradients in thin-films (o-DGT) passive sampler as a tool for accurate measurement of both targeted and suspect polar organic contaminants (primarily pharmaceuticals) in wastewater. First, performance of o-DGT was assessed alongside the polar organic chemical integrative sampler (POCIS) and active sampling at two wastewater treatment facilities using targeted analyses. Overall, water concentrations measured by o-DGT, POCIS, and 24-hr integrative active samples were in good agreement with each other. There were exceptions, including a systematic difference between o-DGT and POCIS at certain sites that we propose was a result of site-specific conditions and a difference in sampling rates between the two techniques. The second component of this work involved suspect screening of the o-DGT extracts using high-resolution, high mass accuracy quadrupole time-of-flight mass spectrometry (QTOF). Lamotrigine, venlafaxine, and des-methylvenlafaxine were three suspect compounds identified and selected as proof-of-concept case studies to determine the feasibility and accuracy of o-DGT for estimating water concentrations based upon predicted sampling rates using a previously validated o-DGT diffusion model. Semi-quantification of the suspect compounds was conducting using an average surrogate response factor based on the suite of compounds measured by the targeted analyses. This, combined with the modelled sampling rates provided time-weighted average wastewater concentrations of the identified suspects within a factor of 2 of the true value, confirmed by isotope dilution with mass labelled internal surrogates. To the knowledge of the authors, this work is the first to demonstrate the utility of the o-DGT passive sampler as a potential environmental screening tool that can be integrated into the rapidly advancing field of non-targeted high resolution mass spectrometry.
Collapse
Affiliation(s)
- Jonathan K Challis
- Department of Chemistry, University of Manitoba, Winnipeg, Manitoba, R3T 2N2 Canada.
| | - Xavier Ortiz Almirall
- Laboratory Services Branch, Ontario Ministry of the Environment, Conservation and Parks, Toronto, Ontario, M9P 3V6, Canada; School of Environmental Studies, Queen's University, Kingston, Ontario, K7L 3N6, Canada
| | - Paul A Helm
- Environmental Monitoring and Reporting Branch, Ontario Ministry of the Environment, Conservation and Parks, Toronto, Ontario, M9P 3V6 Canada
| | - Charles S Wong
- Department of Chemistry, University of Manitoba, Winnipeg, Manitoba, R3T 2N2 Canada; Department of Chemistry and Department of Environmental Studies and Sciences, Richardson College for the Environment, The University of Winnipeg, Winnipeg, Manitoba, R3B 2E9, Canada; School of Environment, Jinan University, Guangzhou, 510632, China
| |
Collapse
|
22
|
Berho C, Robert S, Coureau C, Coisy E, Berrehouc A, Amalric L, Bruchet A. Estimating 42 pesticide sampling rates by POCIS and POCIS-MIP samplers for groundwater monitoring: a pilot-scale calibration. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2020; 27:18565-18576. [PMID: 32198689 DOI: 10.1007/s11356-020-08385-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Accepted: 03/10/2020] [Indexed: 06/10/2023]
Abstract
Pesticides occur in groundwater as a result of agricultural activity. Their monitoring under the Water Framework Directive is based on only a few spot-sampling measurements per year despite their temporal variability. Passive sampling, which was successfully tested in surface water to provide a more representative assessment of contamination, could be applied to groundwater for a better definition of its contamination. However, few reliable calibration data under low water flow are available. The objective of our study thus consisted in determining sampling rates by two types of passive samplers, a POCIS (polar organic chemical integrative sampler) for polar pesticides, and a POCIS-MIP sampler based on a receiving phase of molecular imprinted polymers, specific for AMPA and glyphosate under low flow conditions as exist in groundwater. To our knowledge, this is the first time that sampling rates (sampling rate represents the volume of water from which the analyte is quantitatively extracted by the sampler per unit time) are estimated for groundwater applications. Our calibrations took place in an experimental pilot filled with groundwater and with low water flow (a few metres per day). Pesticide uptake in POCIS showed good linearity, with up to 28 days before reaching equilibrium. Two types of accumulation in POCIS were noted (a linear pattern up to 28 days, and after a time lag of 7 to 14 days). Sampling rates for 38 compounds were calculated and compared with those available in the literature or obtained previously under laboratory conditions. The values obtained were lower by a factor 1 to 14 than those estimated under stirring conditions in the literature, whereas water flow velocity (m s-1) differed by a factor of 2000 to 10,000.
Collapse
Affiliation(s)
- Catherine Berho
- Water, Environment Process Development and Analysis Division, Bureau de Recherches Géologiques et Minières (BRGM), 3 Avenue Claude Guillemin, 45060, Orléans cedex 2, France.
| | - Samuel Robert
- SUEZ, CIRSEE, 38 rue du président Wilson, 78230, le Pecq, France
| | - Charlotte Coureau
- Water, Environment Process Development and Analysis Division, Bureau de Recherches Géologiques et Minières (BRGM), 3 Avenue Claude Guillemin, 45060, Orléans cedex 2, France
| | - Emeline Coisy
- Water, Environment Process Development and Analysis Division, Bureau de Recherches Géologiques et Minières (BRGM), 3 Avenue Claude Guillemin, 45060, Orléans cedex 2, France
| | - Anne Berrehouc
- Water, Environment Process Development and Analysis Division, Bureau de Recherches Géologiques et Minières (BRGM), 3 Avenue Claude Guillemin, 45060, Orléans cedex 2, France
| | - Laurence Amalric
- Water, Environment Process Development and Analysis Division, Bureau de Recherches Géologiques et Minières (BRGM), 3 Avenue Claude Guillemin, 45060, Orléans cedex 2, France
| | - Auguste Bruchet
- SUEZ, CIRSEE, 38 rue du président Wilson, 78230, le Pecq, France
| |
Collapse
|
23
|
Mechelke J, Vermeirssen ELM, Hollender J. Passive sampling of organic contaminants across the water-sediment interface of an urban stream. WATER RESEARCH 2019; 165:114966. [PMID: 31437634 DOI: 10.1016/j.watres.2019.114966] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2019] [Revised: 08/07/2019] [Accepted: 08/08/2019] [Indexed: 06/10/2023]
Abstract
Passive sampling is a well-established tool for monitoring time-weighted average concentrations of polar and semi-polar organic contaminants in streams at flow velocities between 0.1 and 0.4 m s-1. However, its application under low-flow conditions (10-5 to 0.01 m s-1) - as encountered in hyporheic zones - has been scarcely reported. In this study, 3 novel passive sampler configurations were developed for the monitoring of (semi-)polar organic pollutants and related transformation products across the water-sediment interface and thus across varying hydrodynamic conditions. Their design was inspired by Chemcatcher and diffusive gradients in thin films for organics. To determine the most optimal sampler design, an uptake experiment was completed involving the 3 novel passive sampler configurations and a reference Chemcatcher in polar configuration. The experiments consisted of a circular flume that simulated the main channel of a stream and an aquarium with stagnant water that represented the underlying hyporheic zone. The systems were exposed to 192 organic pollutants at environmental concentrations, and the samplers were then collected, extracted and analyzed using liquid chromatography high-resolution mass spectrometry after 2, 6 and 14 days. The configuration that was most insensitive to different hydrodynamic conditions consisted of a reversed-phase sulfonated styrenedivinylbenzene disk as the receiving phase that was covered by an agarose diffusion gel and topped with a polyethersulfone membrane filter. To further evaluate its environmental application, samplers were installed downstream of a sewage treatment plant located at an urban stream in Berlin, Germany (Erpe). The samplers were mounted on custom-made holders which were subsequently embedded in the stream bed to position samplers above (0.30 m) and within the sediment (-0.15/-0.30/-0.45 m) for 11 days. Target and suspect screening workflows were then applied to identify common concentration patterns and link parent attenuation to transformation product formation. A total of 104 concentration profiles were determined, suggesting the efficiency of the proposed sampling strategy in the water-sediment interface. Valsartan acid was the only known transformation product indicative of hyporheic zone-driven attenuation as its concentration in porewater by far exceeded its concentration in surface water. Similar patterns were observed for a larger list of suspected transformation products, of which a sotalol transformation product was tentatively identified. Overall, the established sampling methodology can be effectively used to quantify organic contaminants during low-flow conditions and is suitable for the characterization of attenuation patterns of organic pollutants in hyporheic zones.
Collapse
Affiliation(s)
- Jonas Mechelke
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, 8600, Dübendorf, Switzerland; Institute of Biogeochemistry and Pollutant Dynamics, ETH Zurich, 8092, Zürich, Switzerland
| | | | - Juliane Hollender
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, 8600, Dübendorf, Switzerland; Institute of Biogeochemistry and Pollutant Dynamics, ETH Zurich, 8092, Zürich, Switzerland.
| |
Collapse
|
24
|
Huysman S, Vanryckeghem F, De Paepe E, Smedes F, Haughey SA, Elliott CT, Demeestere K, Vanhaecke L. Hydrophilic Divinylbenzene for Equilibrium Sorption of Emerging Organic Contaminants in Aquatic Matrices. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2019; 53:10803-10812. [PMID: 31378062 DOI: 10.1021/acs.est.9b01814] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Hydrophilic divinylbenzene (DVB) (Bakerbond) has surfaced as a promising sorbent for active sampling of analytes from aqueous matrices over a very broad polarity range. Given this, hydrophilic DVB may likewise offer potential for passive sampling, if sorbent/water partitioning coefficients (Ksw) were to be available. In this work, static exposure batch experiments were performed to quantitatively study the equilibrium sorption of 131 environmentally relevant organic contaminants (P values ranging from -1.30 to 9.85) on hydrophilic DVB. The superior affinity of hydrophilic DVB, as compared to Oasis HLB, for compounds with a broad polarity range was confirmed by functional Fourier-transform infrared spectroscopy and Raman characterization, demonstrating the presence of carboxyl moieties. Concentration effects were studied by increasing compound concentrations in mixture experiments and resulted in the steroidal endocrine disrupting compounds in higher Ksw, while lower Ksw were obtained for the (alkyl)phenols, personal care products, pesticides, pharmaceuticals, and phthalates. Nevertheless, Ksw remained constant in the said design for equilibrium water concentrations at environmentally relevant seawater levels. An independent analysis of thermodynamic parameters (change in enthalpy, entropy, and Gibbs free energy) revealed the nature of the main partitioning processes. While polar (log P < 4) compounds were mainly served by physisorption, nonpolar (log P > 4) compounds also exhibited binding by multiple hydrogen bonding. In conclusion, this research facilitates the future application of hydrophilic DVB for active as well as passive sampling in the analysis of organic contaminants for monitoring purposes and for toxicity testing.
Collapse
Affiliation(s)
- Steve Huysman
- Faculty of Veterinary Medicine, Department of Veterinary Public Health and Food Safety, Laboratory of Chemical Analysis (LCA) , Ghent University , Merelbeke 9820 , Belgium
| | - Francis Vanryckeghem
- Faculty of Bioscience Engineering, Department of Green Chemistry and Technology, Research Group Environmental Organic Chemistry and Technology (EnVOC) , Ghent University , Ghent B-9000 , Belgium
| | - Ellen De Paepe
- Faculty of Veterinary Medicine, Department of Veterinary Public Health and Food Safety, Laboratory of Chemical Analysis (LCA) , Ghent University , Merelbeke 9820 , Belgium
| | - Foppe Smedes
- Faculty of Sciences, Research Centre for Toxic Compounds in the Environment , Masaryk University , Brno 601 77 , Czech Republic
| | - Simon A Haughey
- Institute for Global Food Security, School of Biological Sciences , Queen's University , Belfast BT7 1NN , Northern Ireland
| | - Christopher T Elliott
- Institute for Global Food Security, School of Biological Sciences , Queen's University , Belfast BT7 1NN , Northern Ireland
| | - Kristof Demeestere
- Faculty of Bioscience Engineering, Department of Green Chemistry and Technology, Research Group Environmental Organic Chemistry and Technology (EnVOC) , Ghent University , Ghent B-9000 , Belgium
| | - Lynn Vanhaecke
- Faculty of Veterinary Medicine, Department of Veterinary Public Health and Food Safety, Laboratory of Chemical Analysis (LCA) , Ghent University , Merelbeke 9820 , Belgium
- Institute for Global Food Security, School of Biological Sciences , Queen's University , Belfast BT7 1NN , Northern Ireland
| |
Collapse
|
25
|
Mutzner L, Vermeirssen ELM, Mangold S, Maurer M, Scheidegger A, Singer H, Booij K, Ort C. Passive samplers to quantify micropollutants in sewer overflows: accumulation behaviour and field validation for short pollution events. WATER RESEARCH 2019; 160:350-360. [PMID: 31158617 DOI: 10.1016/j.watres.2019.04.012] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Revised: 04/01/2019] [Accepted: 04/06/2019] [Indexed: 05/21/2023]
Abstract
Contaminants in sewer overflows can contribute to exceedances of environmental quality standards, thus the quantification of contaminants during rainfall events is of relevance. However, monitoring is challenged by i) high spatiotemporal variability of contaminants in events of hard-to-predict durations, and ii) a large number of remote sites, which would imply enormous efforts with traditional sampling equipment. Therefore, we evaluate the applicability of passive samplers (Empore styrene-divinylbenzene reverse phase sulfonated (SDB-RPS)) to monitor a set of 13 polar organic contaminants. We present calibration experiments at high temporal resolution to assess the rate limiting accumulation mechanisms for short events (<36 h), report parameters for typical sewer conditions and compare passive samplers with composite water samples in a field study (three locations, total 10 events). With sampling rates of 0.35-3.5 L/d for 1 h reference time, our calibration results indicate a high sensitivity of passive samplers to sample short, highly variable sewer overflows. The contaminant uptake kinetic shows a fast initial accumulation, which is not well represented with the typical first-order model. Our results indicate that mass transfer to passive samplers is either controlled by the water boundary layer and the sorbent, or by the sorbent alone. Overall, passive sampler concentration estimates are within a factor 0.4 to 3.1 in comparison to composite water samples in the field study. We conclude that passive samplers are a promising approach to monitor a large number of discharge sites although it cannot replace traditional stormwater quality sampling in some cases (e.g. exact load estimates, high temporal resolution). Passive samplers facilitate identifying and prioritizing locations that may require more detailed investigations.
Collapse
Affiliation(s)
- Lena Mutzner
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, 8600, Dübendorf, Switzerland; Institute of Civil, Environmental and Geomatic Engineering, ETH Zürich, 8093, Zurich, Switzerland
| | | | - Simon Mangold
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, 8600, Dübendorf, Switzerland
| | - Max Maurer
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, 8600, Dübendorf, Switzerland; Institute of Civil, Environmental and Geomatic Engineering, ETH Zürich, 8093, Zurich, Switzerland
| | - Andreas Scheidegger
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, 8600, Dübendorf, Switzerland
| | - Heinz Singer
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, 8600, Dübendorf, Switzerland
| | - Kees Booij
- Passive Sampling of Organic Compounds (PaSOC), 8821LV, Kimswerd, the Netherlands
| | - Christoph Ort
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, 8600, Dübendorf, Switzerland.
| |
Collapse
|
26
|
Peijnenburg WJGM. ET&C Best Paper of 2018. ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY 2019; 38:1377-1379. [PMID: 31251845 DOI: 10.1002/etc.4468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
|
27
|
Godlewska K, Stepnowski P, Paszkiewicz M. Application of the Polar Organic Chemical Integrative Sampler for Isolation of Environmental Micropollutants – A Review. Crit Rev Anal Chem 2019; 50:1-28. [DOI: 10.1080/10408347.2019.1565983] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Klaudia Godlewska
- Department of Environmental Analytics, Faculty of Chemistry, University of Gdansk, Gdansk, Poland
| | - Piotr Stepnowski
- Department of Environmental Analytics, Faculty of Chemistry, University of Gdansk, Gdansk, Poland
| | - Monika Paszkiewicz
- Department of Environmental Analytics, Faculty of Chemistry, University of Gdansk, Gdansk, Poland
| |
Collapse
|
28
|
Buzier R, Guibal R, Lissalde S, Guibaud G. Limitation of flow effect on passive sampling accuracy using POCIS with the PRC approach or o-DGT: A pilot-scale evaluation for pharmaceutical compounds. CHEMOSPHERE 2019; 222:628-636. [PMID: 30731383 DOI: 10.1016/j.chemosphere.2019.01.181] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2018] [Revised: 12/14/2018] [Accepted: 01/29/2019] [Indexed: 05/28/2023]
Abstract
Flow velocity is known to alter passive sampling accuracy. We investigated the POCIS (Polar Organic Chemical Integrative Sampler) with PRC (Performance Reference Compounds) approach and Diffusive Gradients in Thin Films samplers (o-DGT) to limit the effect of flow on the quantification accuracy of ten model pharmaceuticals compounds (0.16 ≤ log KOW ≤ 4.51). POCIS and o-DGT samplers were exposed for seven days in controlled pilot-scale (hundreds of liters) experiments under quiescent or flowing (2 < V < 18 cm s-1) conditions. Under flowing conditions, both POCIS-PRC and o-DGT efficiently limited the flow effect and led, in most cases, to biases within analytical uncertainty (20%). Under quiescent conditions, o-DGT performed accurately (bias < 30% for most compounds) whereas the PRC approach was unsuitable to improve upon the accuracy of POCIS (PRC was unable to desorb). Therefore, both approaches are helpful in limiting the effects of flow on accuracy, but only o-DGT is efficient in quiescent conditions. However, o-DGT currently suffers from poorer sensitivity compared to POCIS, but the future development of o-DGT devices with wider windows could overcome this limitation.
Collapse
Affiliation(s)
- Rémy Buzier
- University of Limoges, PEIRENE URA IRSTEA, Equipe DIQeau, 123 Avenue Albert Thomas, 87060, Limoges Cedex, France.
| | - Robin Guibal
- University of Limoges, PEIRENE URA IRSTEA, Equipe DIQeau, 123 Avenue Albert Thomas, 87060, Limoges Cedex, France
| | - Sophie Lissalde
- University of Limoges, PEIRENE URA IRSTEA, Equipe DIQeau, 123 Avenue Albert Thomas, 87060, Limoges Cedex, France
| | - Gilles Guibaud
- University of Limoges, PEIRENE URA IRSTEA, Equipe DIQeau, 123 Avenue Albert Thomas, 87060, Limoges Cedex, France
| |
Collapse
|