Xi H, Ross KE, Hinds J, Molino PJ, Whiley H. Efficacy of chlorine-based disinfectants to control Legionella within premise plumbing systems. WATER RESEARCH 2024; 259:121794. [PMID: 38824796 DOI: 10.1016/j.watres.2024.121794] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 05/14/2024] [Accepted: 05/16/2024] [Indexed: 06/04/2024]
Abstract
Legionella is an opportunistic waterborne pathogen that causes Legionnaires' disease. It poses a significant public health risk, especially to vulnerable populations in health care facilities. It is ubiquitous in manufactured water systems and is transmitted via inhalation or aspiration of aerosols/water droplets generated from water fixtures (e.g., showers and hand basins). As such, the effective management of premise plumbing systems (building water systems) in health care facilities is essential for reducing the risk of Legionnaires' disease. Chemical disinfection is a commonly used control method and chlorine-based disinfectants, including chlorine, chloramine, and chlorine dioxide, have been used for over a century. However, the effectiveness of these disinfectants in premise plumbing systems is affected by various interconnected factors that can make it challenging to maintain effective disinfection. This systematic literature review identifies all studies that have examined the factors impacting the efficacy and decay of chlorine-based disinfectant within premise plumbing systems. A total of 117 field and laboratory-based studies were identified and included in this review. A total of 20 studies directly compared the effectiveness of the different chlorine-based disinfectants. The findings from these studies ranked the typical effectiveness as follows: chloramine > chlorine dioxide > chlorine. A total of 26 factors were identified across 117 studies as influencing the efficacy and decay of disinfectants in premise plumbing systems. These factors were sorted into categories of operational factors that are changed by the operation of water devices and fixtures (such as stagnation, temperature, water velocity), evolving factors which are changed in-directly (such as disinfectant concentration, Legionella disinfectant resistance, Legionella growth, season, biofilm and microbe, protozoa, nitrification, total organic carbon(TOC), pH, dissolved oxygen(DO), hardness, ammonia, and sediment and pipe deposit) and stable factors that are not often changed(such as disinfectant type, pipe material, pipe size, pipe age, water recirculating, softener, corrosion inhibitor, automatic sensor tap, building floor, and construction activity). A factor-effect map of each of these factors and whether they have a positive or negative association with disinfection efficacy against Legionella in premise plumbing systems is presented. It was also found that evaluating the effectiveness of chlorine disinfection as a water risk management strategy is further complicated by varying disinfection resistance of Legionella species and the form of Legionella (culturable/viable but non culturable, free living/biofilm associated, intracellular replication within amoeba hosts). Future research is needed that utilises sensors and other approaches to measure these key factors (such as pH, temperature, stagnation, water age and disinfection residual) in real time throughout premise plumbing systems. This information will support the development of improved models to predict disinfection within premise plumbing systems. The findings from this study will inform the use of chlorine-based disinfection within premise plumbing systems to reduce the risk of Legionnaires disease.
Collapse
Affiliation(s)
- Hao Xi
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia; Enware Pty Ltd, Caringbah, NSW, Australia.
| | - Kirstin E Ross
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
| | - Jason Hinds
- ARC Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park, SA, Australia; Enware Pty Ltd, Caringbah, NSW, Australia
| | | | - Harriet Whiley
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia; ARC Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park, SA, Australia
| |
Collapse
|
2
|
Lytle DA, Pfaller S, Muhlen C, Struewing I, Triantafyllidou S, White C, Hayes S, King D, Lu J. A comprehensive evaluation of monochloramine disinfection on water quality, Legionella and other important microorganisms in a hospital. WATER RESEARCH 2021; 189:116656. [PMID: 33249307 PMCID: PMC8133025 DOI: 10.1016/j.watres.2020.116656] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 11/15/2020] [Accepted: 11/16/2020] [Indexed: 05/22/2023]
Abstract
Opportunistic pathogens such as Legionella are of significant public health concern in hospitals. Microbiological and water chemistry parameters in hot water throughout an Ohio hospital were monitored monthly before and after the installation of a monochloramine disinfection system over 16 months. Water samples from fifteen hot water sampling sites as well as the municipal water supply entering the hospital were analyzed using both culture and qPCR assays for specific microbial pathogens including Legionella, Pseudomonas spp., nontuberculous Mycobacteria [NTM], as well as for heterotrophic bacteria. Legionella culture assays decreased from 68% of all sites being positive prior to monochloramine addition to 6% positive after monochloramine addition, and these trends were parallel to qPCR results. Considering all samples, NTMs by culture were significantly reduced from 61% to 14% positivity (p<0.001) after monochloramine treatment. Mycobacterium genus-specific qPCR positivity was reduced from 92% to 65%, but the change was not significant. Heterotrophic bacteria (heterotrophic bacteria plate counts [HPCs]) exhibited large variability which skewed statistical results on a per room basis. However, when all samples were considered, a significant decrease in HPCs was observed after monochloramine addition. Lastly, Pseudomonas aeruginosa and Vermamoeba vermiformis demonstrated large and significant decrease of qPCR signals post-chloramination. General water chemistry parameters including monochloramine residual, nitrate, nitrite, pH, temperature, metals and total trihalomethanes (TTHMs) were also measured. Significant monochloramine residuals were consistently observed at all sampling sites with very little free ammonia present and no water quality indications of nitrification (e.g., pH decrease, elevated nitrite or nitrate). The addition of monochloramine had no obvious impact on metals (lead, copper and iron) and disinfection by-products.
Collapse
Affiliation(s)
- Darren A Lytle
- U.S. Environmental Protection Agency, ORD, Center for Environmental Solutions and Emergency Response (CESER), 26 W. Martin Luther King Drive, Cincinnati, OH, 45268, United States.
| | - Stacy Pfaller
- U.S. Environmental Protection Agency, ORD, Center for Environmental Solutions and Emergency Response (CESER), 26 W. Martin Luther King Drive, Cincinnati, OH, 45268, United States
| | - Christy Muhlen
- U.S. Environmental Protection Agency, ORD, Center for Environmental Solutions and Emergency Response (CESER), 26 W. Martin Luther King Drive, Cincinnati, OH, 45268, United States
| | - Ian Struewing
- U.S. Environmental Protection Agency, ORD, Center for Environmental Measurement and Modelling (CEMM), 26 W. Martin Luther King Drive, Cincinnati, OH 45268, United States
| | - Simoni Triantafyllidou
- U.S. Environmental Protection Agency, ORD, Center for Environmental Solutions and Emergency Response (CESER), 26 W. Martin Luther King Drive, Cincinnati, OH, 45268, United States
| | - Colin White
- Ohio Environmental Protection Agency, Emerging Contaminants Section, Division of Drinking and Ground Waters, 50 West Town Street, Suite 700 Columbus, OH 43215, United States
| | - Sam Hayes
- U.S. Environmental Protection Agency, ORD, Center for Environmental Solutions and Emergency Response (CESER), 26 W. Martin Luther King Drive, Cincinnati, OH, 45268, United States
| | - Dawn King
- U.S. Environmental Protection Agency, ORD, Center for Environmental Solutions and Emergency Response (CESER), 26 W. Martin Luther King Drive, Cincinnati, OH, 45268, United States
| | - Jingrang Lu
- U.S. Environmental Protection Agency, ORD, Center for Environmental Measurement and Modelling (CEMM), 26 W. Martin Luther King Drive, Cincinnati, OH 45268, United States
| |
Collapse
|
3
|
Wang H, Pryor MA, Edwards MA, Falkinham JO, Pruden A. Effect of GAC pre-treatment and disinfectant on microbial community structure and opportunistic pathogen occurrence. WATER RESEARCH 2013; 47:5760-72. [PMID: 23906775 DOI: 10.1016/j.watres.2013.06.052] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2012] [Revised: 06/21/2013] [Accepted: 06/27/2013] [Indexed: 05/10/2023]
Abstract
Opportunistic pathogens in potable water systems are an emerging health concern; however, the factors influencing their proliferation are poorly understood. Here we investigated the effects of prior granular activated carbon (GAC) biofiltration [GAC-filtered water, unfiltered water, and a blend (30% GAC filtered and 70% unfiltered water)] and disinfectant type (chlorine, chloramine) on opportunistic pathogen occurrence using five annular reactors (ARs) to simulate water distribution systems, particularly premise plumbing. GAC pre-treatment effectively reduced total organic carbon (TOC), resulting in three levels of influent TOC investigated. Quantitative polymerase chain reaction (q-PCR) provided molecular evidence of natural colonization of Legionella spp., Mycobacterium spp., Acanthamoeba spp., Hartmannella vermiformis and Mycobacterium avium on AR coupons. Cultivable mycobacteria and amoeba, including pathogenic species, were also found in bulk water and biofilm samples. While q-PCR tends to overestimate live cells, it provided a quantitative comparison of target organisms colonizing the AR biofilms in terms of gene copy numbers. In most cases, total bacteria and opportunistic pathogens were higher in the three undisinfected ARs, but the levels were not proportional to the level of GAC pre-treatment/TOC. Chlorine was more effective for controlling mycobacteria and Acanthamoeba, whereas chloramine was more effective for controlling Legionella. Both chlorine and chloramine effectively inhibited M. avium and H. vermiformis colonization. Pyrosequencing of 16S rRNA genes in coupon biofilms revealed a significant effect of GAC pre-treatment and disinfectant type on the microbial community structure. Overall, this study provides insights into the potential of different disinfectants and GAC biofilters at the treatment plant and in buildings to control downstream opportunistic pathogens and broader drinking water microbial communities.
Collapse
Affiliation(s)
- Hong Wang
- Via Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA 24061, USA
| | | | | | | | | |
Collapse
|