1
|
Optimal Morphometric Characteristics of a Tubular Polymeric Scaffold to Promote Peripheral Nerve Regeneration: A Scoping Review. Polymers (Basel) 2022; 14:polym14030397. [PMID: 35160387 PMCID: PMC8838152 DOI: 10.3390/polym14030397] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Revised: 01/05/2022] [Accepted: 01/13/2022] [Indexed: 12/27/2022] Open
Abstract
Cellular behavior in nerve regeneration is affected by the architecture of the polymeric nerve guide conduits (NGCs); therefore, design features of polymeric NGCs are critical for neural tissue engineering. Hence, the purpose of this scoping review is to summarize the adequate quantitative/morphometric parameters of the characteristics of NGC that provide a supportive environment for nerve regeneration, enhancing the understanding of a previous study. 394 studies were found, of which 29 studies were selected. The selected studies revealed four morphometric characteristics for promoting nerve regeneration: wall thickness, fiber size, pore size, and porosity. An NGC with a wall thickness between 250–400 μm and porosity of 60–80%, with a small pore on the inner surface and a large pore on the outer surface, significantly favored nerve regeneration; resulting in an increase in nutrient permeability, retention of neurotrophic factors, and optimal mechanical properties. On the other hand, the superiority of electrospun fibers is described; however, the size of the fiber is controversial in the literature, obtaining optimal results in the range of 300 nm to 30 µm. The incorporation of these optimal morphometric characteristics will encourage nerve regeneration and help reduce the number of experimental studies as it will provide the initial morphometric parameters for the preparation of an NGC.
Collapse
|
2
|
Pozzobon LG, Sperling LE, Teixeira CE, Malysz T, Pranke P. Development of a conduit of PLGA-gelatin aligned nanofibers produced by electrospinning for peripheral nerve regeneration. Chem Biol Interact 2021; 348:109621. [PMID: 34450165 DOI: 10.1016/j.cbi.2021.109621] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2021] [Revised: 03/27/2021] [Accepted: 08/04/2021] [Indexed: 11/17/2022]
Abstract
A promising alternative to conventional nerve grafting is the use of artificial grafts made from biodegradable and biocompatible materials and support cells. The aim of this study has been to produce a biodegradable nerve conduit and investigate the cytocompatibility with stem cells and its regeneration promoting properties in a rat animal model. A poly (lactic-co-glycolic acid) (PLGA) conduit of aligned nanofibers was produced by the electrospinning method, functionalized with gelatin and seeded either with mouse embryonic stem cells (mESCs) or with human mesenchymal stem cells (SHED). The cell proliferation and viability were analyzed in vitro. The conduits were implanted in a rat model of sciatic nerve lesion by transection. The functional recovery was monitored for 8 weeks using the Sciatic Functional Index (SFI) and histological analyses were used to assess the nerve regeneration. Scaffolds of aligned PLGA fibers with an average diameter of 0.90 ± 0.36 μm and an alignment coefficient of 0.817 ± 0.07 were produced. The treatment with gelatin increased the fiber diameter to 1.05 ± 0.32 μm, reduced the alignment coefficient to 0.655 ± 0.045 and made the scaffold very hydrophilic. The cell viability and Live/dead assay showed that the stem cells remained viable and proliferated after 7 days in culture. Confocal images of phalloidin/DAPI staining showed that the cells adhered and proliferated widely, in fully adaptation with the biomaterial. The SFI values of the group that received the conduit were similar to the values of the control lesioned group. In conclusion, conduits composed of PLGA-gelatin nanofibers were produced and promoted a very good interaction with the stem cells. Although in vitro studies have shown this biomaterial to be a promising biomaterial for the regeneration of nerve tissue, in vivo studies of this graft have not shown significant improvements in nerve regeneration.
Collapse
Affiliation(s)
- Laura Gonçalves Pozzobon
- Hematology and Stem Cell Laboratory, Faculty of Pharmacy, Av. Ipiranga 2752, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil; Stem Cell Laboratory, Fundamental Health Science Institute, Rua Sarmento Leite, 500, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil.
| | - Laura Elena Sperling
- Hematology and Stem Cell Laboratory, Faculty of Pharmacy, Av. Ipiranga 2752, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil; Stem Cell Laboratory, Fundamental Health Science Institute, Rua Sarmento Leite, 500, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil
| | - Cristian E Teixeira
- Hematology and Stem Cell Laboratory, Faculty of Pharmacy, Av. Ipiranga 2752, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil; Stem Cell Laboratory, Fundamental Health Science Institute, Rua Sarmento Leite, 500, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil
| | - Tais Malysz
- Instituto de Ciências básicas da Saúde, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil
| | - Patricia Pranke
- Hematology and Stem Cell Laboratory, Faculty of Pharmacy, Av. Ipiranga 2752, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil; Stem Cell Laboratory, Fundamental Health Science Institute, Rua Sarmento Leite, 500, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil; Instituto de Pesquisa com Células-tronco, IPCT, Porto Alegre, RS, Brazil
| |
Collapse
|
3
|
Apablaza JA, Lezcano MF, Lopez Marquez A, Godoy Sánchez K, Oporto GH, Dias FJ. Main Morphological Characteristics of Tubular Polymeric Scaffolds to Promote Peripheral Nerve Regeneration-A Scoping Review. Polymers (Basel) 2021; 13:polym13152563. [PMID: 34372166 PMCID: PMC8347244 DOI: 10.3390/polym13152563] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2021] [Revised: 07/27/2021] [Accepted: 07/28/2021] [Indexed: 11/16/2022] Open
Abstract
The "nerve guide conduits" (NGC) used in nerve regeneration must mimic the natural environment for proper cell behavior. OBJECTIVE To describe the main morphological characteristics of polymeric NGC to promote nerve regeneration. METHODS A scoping review was performed following the Preferred Reporting Items for Systematic reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) criteria in the PubMed, Web of Science, Science Direct, and Scientific Electronic Library Online (SciELO) databases. Primary studies that considered/evaluated morphological characteristics of NGC to promote nerve regeneration were included. RESULT A total of 704 studies were found, of which 52 were selected. The NGC main morphological characteristics found in the literature were: (I) NGC diameter affects the mechanical properties of the scaffold. (II) Wall thickness of NGC determines the exchange of nutrients, molecules, and neurotrophins between the internal and external environment; and influences the mechanical properties and biodegradation, similarly to NGC (III) porosity, (IV) pore size, and (V) pore distribution. The (VI) alignment of the NGC fibers influences the phenotype of cells involved in nerve regeneration. In addition, the (VII) thickness of the polymeric fiber influences neurite extension and orientation. CONCLUSIONS An NGC should have its diameter adjusted to the nerve with wall thickness, porosity, pore size, and distribution of pores, to favor vascularization, permeability, and exchange of nutrients, and retention of neurotrophic factors, also favoring its mechanical properties and biodegradability.
Collapse
Affiliation(s)
- Josefa Alarcón Apablaza
- Research Centre in Dental Sciences (CICO-UFRO), Dental School—Facultad de Odontología, Universidad de La Frontera, Temuco 4780000, Chile; (J.A.A.); (M.F.L.); (G.H.O.)
- Program of Master in Dental Science, Dental School, Universidad de La Frontera, Temuco 4780000, Chile
| | - María Florencia Lezcano
- Research Centre in Dental Sciences (CICO-UFRO), Dental School—Facultad de Odontología, Universidad de La Frontera, Temuco 4780000, Chile; (J.A.A.); (M.F.L.); (G.H.O.)
- Department of Integral Adults Dentistry, Dental School—Facultad de Odontología, Universidad de La Frontera, Temuco 4780000, Chile
- Laboratorio de Cibernética, Departamento de Bioingeniería, Facultad de Ingeniería, Universidad Nacional de Entre Ríos, Oro Verde 3100, Argentina
| | - Alex Lopez Marquez
- HAWK—Hochschule für Angewandte Wissenschaften und Kunst, 37085 Göttingen, Germany;
| | - Karina Godoy Sánchez
- Scientific and Technological Bioresource Nucleus (BIOREN-UFRO), Universidad de La Frontera, Temuco 4780000, Chile;
- Center of Molecular Biology and Phamacogenetics, Universidad de La Frontera, Temuco 4780000, Chile
| | - Gonzalo H. Oporto
- Research Centre in Dental Sciences (CICO-UFRO), Dental School—Facultad de Odontología, Universidad de La Frontera, Temuco 4780000, Chile; (J.A.A.); (M.F.L.); (G.H.O.)
- Department of Integral Adults Dentistry, Dental School—Facultad de Odontología, Universidad de La Frontera, Temuco 4780000, Chile
| | - Fernando José Dias
- Research Centre in Dental Sciences (CICO-UFRO), Dental School—Facultad de Odontología, Universidad de La Frontera, Temuco 4780000, Chile; (J.A.A.); (M.F.L.); (G.H.O.)
- Department of Integral Adults Dentistry, Dental School—Facultad de Odontología, Universidad de La Frontera, Temuco 4780000, Chile
- Correspondence: ; Tel.: +56-9-8474-6702
| |
Collapse
|
4
|
Kinaci A, van Thoor S, Redegeld S, Tooren M, van Doormaal TPC. Ex vivo evaluation of a multilayered sealant patch for watertight dural closure: cranial and spinal models. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2021; 32:85. [PMID: 34297226 PMCID: PMC8302489 DOI: 10.1007/s10856-021-06552-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Cerebrospinal fluid leakage is a frequent complication after cranial and spinal surgery. To prevent this complication and seal the dura watertight, we developed Liqoseal, a dural sealant patch comprising a watertight polyesterurethane layer and an adhesive layer consisting of poly(DL-lactide-co-ε-caprolactone) copolymer and multiarmed N-hydroxylsuccinimide functionalized polyethylene glycol. We compared acute burst pressure and resistance to physiological conditions for 72 h of Liqoseal, Adherus, Duraseal, Tachosil, and Tisseel using computer-assisted models and fresh porcine dura. The mean acute burst pressure of Liqoseal in the cranial model (145 ± 39 mmHg) was higher than that of Adherus (87 ± 47 mmHg), Duraseal (51 ± 42 mmHg) and Tachosil (71 ± 16 mmHg). Under physiological conditions, cranial model resistance test results showed that 2 of 3 Liqoseal sealants maintained dural attachment during 72 hours as opposed to 3 of 3 for Adherus and Duraseal and 0 of 3 for Tachosil. The mean burst pressure of Liqoseal in the spinal model (233 ± 81 mmHg) was higher than that of Tachosil (123 ± 63 mmHg) and Tisseel (23 ± 16 mmHg). Under physiological conditions, spinal model resistance test results showed that 2 of 3 Liqoseal sealants maintained dural attachment for 72 hours as opposed to 3 of 3 for Adherus and 0 of 3 for Duraseal and Tachosil. This novel study showed that Liqoseal is capable of achieving a strong watertight seal over a dural defect in ex vivo models.
Collapse
Affiliation(s)
- A Kinaci
- Department of Neurology and Neurosurgery, Brain Center Rudolph Magnus, University Medical Centre Utrecht, Utrecht, The Netherlands
- Brain Technology Institute, Utrecht, The Netherlands
| | - S van Thoor
- Brain Technology Institute, Utrecht, The Netherlands
| | - S Redegeld
- Brain Technology Institute, Utrecht, The Netherlands
| | - M Tooren
- Polyganics BV, Groningen, The Netherlands
| | - T P C van Doormaal
- Department of Neurology and Neurosurgery, Brain Center Rudolph Magnus, University Medical Centre Utrecht, Utrecht, The Netherlands.
- Brain Technology Institute, Utrecht, The Netherlands.
| |
Collapse
|
5
|
Behr J, Irvine SA, Thwin C, Shah AH, Bae MK, Zussman E, Venkatraman S. Matching Static and Dynamic Compliance of Small‐Diameter Arteries, with Poly(lactide‐
co
‐caprolactone) Copolymers: In Vitro and In Vivo Studies. Macromol Biosci 2020; 20:e1900234. [DOI: 10.1002/mabi.201900234] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 11/06/2019] [Indexed: 12/19/2022]
Affiliation(s)
- Jean‐Marc Behr
- School of Materials Science and EngineeringNanyang Technological University 50 Nanyang Avenue Singapore 639798 Singapore
| | - Scott Alexander Irvine
- School of Materials Science and EngineeringNanyang Technological University 50 Nanyang Avenue Singapore 639798 Singapore
| | - Chaw‐Su Thwin
- School of Materials Science and EngineeringNanyang Technological University 50 Nanyang Avenue Singapore 639798 Singapore
| | - Ankur Harish Shah
- School of Materials Science and EngineeringNanyang Technological University 50 Nanyang Avenue Singapore 639798 Singapore
| | - Min‐Chul Kraun Bae
- School of Materials Science and EngineeringNanyang Technological University 50 Nanyang Avenue Singapore 639798 Singapore
| | - Eyal Zussman
- Nano Engineering groupFaculty of Mechanical EngineeringTechnion–Israel Institute of Technology Haifa 32000 Israel
| | - Subbu Venkatraman
- School of Materials Science and EngineeringNanyang Technological University 50 Nanyang Avenue Singapore 639798 Singapore
| |
Collapse
|
6
|
Pappalardo D, Mathisen T, Finne-Wistrand A. Biocompatibility of Resorbable Polymers: A Historical Perspective and Framework for the Future. Biomacromolecules 2019; 20:1465-1477. [PMID: 30855137 DOI: 10.1021/acs.biomac.9b00159] [Citation(s) in RCA: 83] [Impact Index Per Article: 16.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The history of resorbable polymers containing glycolide, lactide, ε-caprolactone and trimethylene carbonate, with a special emphasis being placed on the time frame of the 1960s-1990s is described. Reviewing the history is valuable when looking into the future perspectives regarding how and where these monomers should be used. This story includes scientific evaluations indicating that these polymers are safe to use in medical devices, while the design of the medical device is not considered in this report. In particular, we present the data regarding the tissue response to implanted polymers, as well as the toxicity and pharmacokinetics of their degradation products. In the translation of these polymers from "the bench to the bedside," various challenges have been faced by surgeons, medical doctors, biologists, material engineers and polymer chemists. This Perspective highlights the visionary role played by the pioneers, addressing the problems that occurred on a case by case basis in translational medicine.
Collapse
Affiliation(s)
- Daniela Pappalardo
- Department of Science and Technology , University of Sannio , via dei Mulini , 82100 Benevento , Italy
| | | | - Anna Finne-Wistrand
- Department of Fibre and Polymer Technology , KTH Royal Institute of Technology , 114 28 Stockholm , Sweden
| |
Collapse
|
7
|
Duffy P, McMahon S, Wang X, Keaveney S, O'Cearbhaill ED, Quintana I, Rodríguez FJ, Wang W. Synthetic bioresorbable poly-α-hydroxyesters as peripheral nerve guidance conduits; a review of material properties, design strategies and their efficacy to date. Biomater Sci 2019; 7:4912-4943. [DOI: 10.1039/c9bm00246d] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Implantable tubular devices known as nerve guidance conduits (NGCs) have drawn considerable interest as an alternative to autografting in the repair of peripheral nerve injuries.
Collapse
Affiliation(s)
- Patrick Duffy
- The Charles Institute of Dermatology
- School of Medicine
- University College Dublin
- Dublin
- Ireland
| | - Seán McMahon
- Ashland Specialties Ireland Ltd
- Synergy Centre
- Dublin
- Ireland
| | - Xi Wang
- The Charles Institute of Dermatology
- School of Medicine
- University College Dublin
- Dublin
- Ireland
| | - Shane Keaveney
- School of Mechanical & Materials Engineering
- UCD Centre for Biomedical Engineering
- UCD Conway Institute of Biomolecular and Biomedical Research
- University College Dublin
- Dublin
| | - Eoin D. O'Cearbhaill
- School of Mechanical & Materials Engineering
- UCD Centre for Biomedical Engineering
- UCD Conway Institute of Biomolecular and Biomedical Research
- University College Dublin
- Dublin
| | - Iban Quintana
- IK4-Tekniker
- Surface Engineering and Materials Science Unit
- Eibar
- Spain
| | | | - Wenxin Wang
- The Charles Institute of Dermatology
- School of Medicine
- University College Dublin
- Dublin
- Ireland
| |
Collapse
|
8
|
Meek M, Den Dunnen W, Robinson P, Pennings A, Schakenraad J. Evaluation of Functional Nerve Recovery after Reconstruction with a New Biodegradable Poly (DL-Lactide-∊-Caprolactone) Nerve Guide. Int J Artif Organs 2018. [DOI: 10.1177/039139889702000809] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The aim of this study was to evaluate functional nerve recovery following reconstruction of a 1 cm gap in the sciatic nerve of a rat, using a new biodegradable p (DLLA-∊-CL) nerve guide. To evaluate both motor and sensory nerve recovery, walking track analysis and electrostimulation tests were carried out after implantation periods, ranging from 3 to 15 weeks post-operatively. The first signs of functional nerve recovery were observed after 3 weeks. After 15 weeks, 70% of the motor - and 90% of the sensory nerve function was re-established. Return of nerve function was better, in comparison with results from other studies. This study demonstrated successful functional nerve recovery after the reconstruction of a 1 cm nerve gap with a biodegradable p(DLLA-∊-CL) nerve guide.
Collapse
Affiliation(s)
- M.F Meek
- Centre for Biomedical Technology, Division of Biomaterials, University of Groningen, Groningen
| | | | - P.H. Robinson
- Department of Plastic and Reconstructive Surgery, University Hospital Groningen, Groningen
| | - A.J. Pennings
- Department of Polymer Chemistry, University of Groningen, Groningen - The Netherlands
| | - J.M. Schakenraad
- Centre for Biomedical Technology, Division of Biomaterials, University of Groningen, Groningen
| |
Collapse
|
9
|
Galla TJ, Vedecnik SV, Halbgewachs J, Steinmann S, Friedrich C, Stark GB. Fibrin/Schwann Cell Matrix in Poly-Epsilon-Caprolactone Conduits Enhances Guided Nerve Regeneration. Int J Artif Organs 2018; 27:127-36. [PMID: 15068007 DOI: 10.1177/039139880402700208] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The goal of this study was to investigate if a three dimensional matrix, loaded homogeneously with Schwann cells and the neurotrophic factor LIF (leukemia inhibitory factor), enhances regeneration in a biodegradable nerve guidance channel as compared to non-structured cell suspensions. Therefore a 10 mm nerve gap in the buccal branch of the rat's facial nerve was bridged with tubular PCL (poly-epsilon-caprolactone) conduits filled with no matrix, Schwann cells, the three dimensional fibrin/Schwann cell matrix or the fibrin/Schwann cell matrix added with LIF. Four weeks after the nerve defects were bridged histological and morphometric analyses of the implants were performed. In conclusion, the three dimensional fibrin/Schwann cells matrix enhanced the quantity and the quality of peripheral nerve regeneration through PCL conduits. The application of LIF prevented hyperneurotization. Therefore, tissue engineered fibrin/Schwann cells matrices are new invented biocompatible and biodegradable devices for enhancing peripheral nerve regeneration as compared to non-structured cell suspensions without neurotrophic factors.
Collapse
Affiliation(s)
- T J Galla
- Department of Hand and Plastic Surgery, ValleyTEC, Albert-Ludwigs-University, Freiburg, Germany.
| | | | | | | | | | | |
Collapse
|
10
|
Barakat-Walter I, Kraftsik R. Stimulating effect of thyroid hormones in peripheral nerve regeneration: research history and future direction toward clinical therapy. Neural Regen Res 2018; 13:599-608. [PMID: 29722302 PMCID: PMC5950660 DOI: 10.4103/1673-5374.230274] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
Injury to peripheral nerves is often observed in the clinic and severe injuries may cause loss of motor and sensory functions. Despite extensive investigation, testing various surgical repair techniques and neurotrophic molecules, at present, a satisfactory method to ensuring successful recovery does not exist. For successful molecular therapy in nerve regeneration, it is essential to improve the intrinsic ability of neurons to survive and to increase the speed of axonal outgrowth. Also to induce Schwann cell phenotypical changes to prepare the local environment favorable for axonal regeneration and myelination. Therefore, any molecule that regulates gene expression of both neurons and Schwann cells could play a crucial role in peripheral nerve regeneration. Clinical and experimental studies have reported that thyroid hormones are essential for the normal development and function of the nervous system, so they could be candidates for nervous system regeneration. This review provides an overview of studies devoted to testing the effect of thyroid hormones on peripheral nerve regeneration. Also it emphasizes the importance of combining biodegradable tubes with local administration of triiodothyronine for future clinical therapy of human severe injured nerves. We highlight that the local and single administration of triiodothyronine within biodegradable nerve guide improves significantly the regeneration of severed peripheral nerves, and accelerates functional recovering. This technique provides a serious step towards future clinical application of triiodothyronine in human severe injured nerves. The possible regulatory mechanism by which triiodothyronine stimulates peripheral nerve regeneration is a rapid action on both axotomized neurons and Schwann cells.
Collapse
Affiliation(s)
- I Barakat-Walter
- Department of Fundamental Neurosciences, Faculty of Biology and Medicine, University of Lausanne, Lausanne, Switzerland
| | - R Kraftsik
- Department of Fundamental Neurosciences, Faculty of Biology and Medicine, University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
11
|
Pestana FM, Domingues RCC, Oliveira JT, Durço DFPA, Goulart CO, Mendonça HR, Dos Santos ACR, de Campos NT, da Silva BT, Pereira CC, Borges CP, Martinez AMB. Comparison of morphological and functional outcomes of mouse sciatic nerve repair with three biodegradable polymer conduits containing poly(lactic acid). Neural Regen Res 2018; 13:1811-1819. [PMID: 30136697 PMCID: PMC6128044 DOI: 10.4103/1673-5374.238712] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Poly(lactic acid) (PLA)-containing nerve guidance conduits (NGCs) are currently being investigated for nerve repair as an alternative to autograft, which leads to permanent functional impairment in the territory innervated by the removed nerve. Combination of polymers modifies the physical properties of the conduits, altering their nerve-guidance properties. Conduits made from PLA-only or combined with other polymers have been used successfully for nerve repair, but their efficiency has not been compared. We compared the morphological and functional outcomes of peripheral nerve repair by using NGCs made of poly(lactic acid) and combined or not with polycaprolactone (PLA/PCL) or polyvinylpyrrolidone (PLA/PVP). To assess the functional recovery, we employed a mechanical hyperalgesia analysis, sciatic functional index (SFI), and electroneuromyography. The mechanical hyperalgesia analysis showed that the PLA group improved more rapidly than the PLA/PVP and PLA/PCL groups; similarly, in the electroneuromyography assay, the PLA group exhibited higher amplitude than the PLA/PCL and PLA/PVP groups. However, the SFI improvement rates did not differ among the groups. Morphologically, the PLA group showed more vascularization, while the nerve fiber regeneration did not differ among the groups. In conclusion, the PLA-only conduits were superior to the other NGCs tested for nerve repair.
Collapse
Affiliation(s)
- Fernanda Marques Pestana
- Pós Graduação em Ciências Morfológicas, Instituto de Ciências Biomédicas-UFRJ; Laboratório de Neurodegeneração e Reparo - Faculdade de Medicina - HUCFF-UFRJ, Rio de Janeiro, RJ, Brazil
| | | | - Júlia Teixeira Oliveira
- Anatomia Patológica - Faculdade de Medicina - HUCFF -UFRJ; Laboratório de Neurodegeneração e Reparo - Faculdade de Medicina - HUCFF-UFRJ, Rio de Janeiro, RJ, Brazil
| | - Daniela F P A Durço
- Anatomia Patológica - Faculdade de Medicina - HUCFF -UFRJ; Laboratório de Neurodegeneração e Reparo - Faculdade de Medicina - HUCFF-UFRJ, Rio de Janeiro, RJ, Brazil
| | - Camila Oliveira Goulart
- Anatomia Patológica - Faculdade de Medicina - HUCFF -UFRJ; Laboratório de Neurodegeneração e Reparo - Faculdade de Medicina - HUCFF-UFRJ, Rio de Janeiro, RJ, Brazil
| | - Henrique Rocha Mendonça
- Anatomia Patológica - Faculdade de Medicina - HUCFF -UFRJ; Laboratório de Neurodegeneração e Reparo - Faculdade de Medicina - HUCFF-UFRJ, Rio de Janeiro, RJ; Polo Universitário de Macaé, Laboratório Integrado de Produtos Bioativos e Biociências, Macaé, UFRJ, Brazil
| | - Anne Caroline Rodrigues Dos Santos
- Anatomia Patológica - Faculdade de Medicina - HUCFF -UFRJ; Laboratório de Neurodegeneração e Reparo - Faculdade de Medicina - HUCFF-UFRJ, Rio de Janeiro, RJ, Brazil
| | - Natália Tavares de Campos
- Anatomia Patológica - Faculdade de Medicina - HUCFF -UFRJ; Laboratório de Neurodegeneração e Reparo - Faculdade de Medicina - HUCFF-UFRJ, Rio de Janeiro, RJ, Brazil
| | - Beatriz Theodoro da Silva
- Anatomia Patológica - Faculdade de Medicina - HUCFF -UFRJ; Laboratório de Neurodegeneração e Reparo - Faculdade de Medicina - HUCFF-UFRJ, Rio de Janeiro, RJ, Brazil
| | | | | | - Ana Maria Blanco Martinez
- Pós Graduação em Ciências Morfológicas, Instituto de Ciências Biomédicas-UFRJ; Anatomia Patológica - Faculdade de Medicina - HUCFF -UFRJ; Laboratório de Neurodegeneração e Reparo - Faculdade de Medicina - HUCFF-UFRJ, Rio de Janeiro, RJ, Brazil
| |
Collapse
|
12
|
Pixley SK, Hopkins TM, Little KJ, Hom DB. Evaluation of peripheral nerve regeneration through biomaterial conduits via micro-CT imaging. Laryngoscope Investig Otolaryngol 2016; 1:185-190. [PMID: 28894816 PMCID: PMC5510275 DOI: 10.1002/lio2.41] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/20/2016] [Indexed: 12/31/2022] Open
Abstract
OBJECTIVE Hollow nerve conduits made of natural or synthetic biomaterials are used clinically to aid regeneration of peripheral nerves damaged by trauma or disease. To support healing, conduit lumen patency must be maintained until recovery occurs. New methods to study conduit structural integrity would provide an important means to optimize conduits in preclinical studies. We explored a novel combined technique to examine structural integrity of two types of nerve conduits after in vivo healing. STUDY DESIGN Micro-CT imaging with iodine contrast was combined with histological analysis to examine two different nerve conduits after in vivo nerve reconstruction in rats. MATERIALS AND METHODS Sciatic nerve gaps in adult Lewis rats were reconstructed with poly(caprolactone) (PCL, 1.6 cm gap, 14-week survival) or silicone (1 cm gap, 6-week survival) conduits (N = 12 total). Conduits with regenerating tissues were imaged by micro-CT with iodine contrast and compared to the histology (hematoxylin and eosin, immunostaining for axons) of regenerated tissues after iodine removal. RESULTS PCL nerve conduits showed extensive breakage throughout their length, but all showed successful nerve growth through the conduits. The silicone conduits remained intact, although significant constriction was uniquely detected by micro-CT, with 1 of 6 animals showing incomplete tissue regeneration. CONCLUSIONS Micro-CT with iodine contrast offers a unique and valuable means to determine 3D structural integrity of nerve conduits and nerve healing following reconstruction. Furthermore, this paper shows that even if conduit compression and degradation occur, nerve regeneration can still take place.
Collapse
Affiliation(s)
- Sarah K Pixley
- Department of Molecular and Cellular Physiology (S.K.P., T.M.H.) Cincinnati Children's Hospital Medical Center Cincinnati Ohio U.S.A
| | - Tracy M Hopkins
- Department of Molecular and Cellular Physiology (S.K.P., T.M.H.) Cincinnati Children's Hospital Medical Center Cincinnati Ohio U.S.A
| | - Kevin J Little
- Pediatric Hand and Upper Extremity Center (K.J.L.), Cincinnati Children's Hospital Medical Center Cincinnati Ohio U.S.A
| | - David B Hom
- Department of Otolaryngology-Head and Neck Surgery (D.B.H.) University of Cincinnati School of Medicine Cincinnati Ohio U.S.A
| |
Collapse
|
13
|
Isaacs J, Mallu S, Yan W, Little B. Consequences of oversizing: nerve-to-nerve tube diameter mismatch. J Bone Joint Surg Am 2014; 96:1461-7. [PMID: 25187585 DOI: 10.2106/jbjs.m.01420] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Although commercially available nerve conduits are an accepted tool for overcoming short gaps in peripheral nerve repair, unexplained inconsistencies in clinical outcomes are not uncommon. Although exceeding the critical gap size and nerve caliber are most frequently cited as the source of these failures, oversizing of the nerve conduit in relation to the nerve diameter may be a previously unrecognized factor as well. METHODS Sixty female Sprague-Dawley rats underwent excision of a 10-mm section midway between the sciatic notch and the sciatic nerve division of one hindlimb. The defect was immediately repaired by reversing the resected nerve section and suturing it back in place (reverse autograft) (group A, n = 13) or it was repaired with a 14-mm nerve tube of 3 mm in diameter (group B, n = 12), 2 mm in diameter (group C, n = 15), or 1.5 mm in diameter (group D, n = 15). At twelve weeks, the rodents underwent muscle strength testing before harvest of muscle and nerve (including the conduit) for histomorphologic assessment. RESULTS Most conduits from group B were collapsed at final inspection and demonstrated diminished nerve regenerate. Muscle atrophy was most pronounced in groups B and C (p < 0.05), although normalized muscle contraction force was weakest in group B (p < 0.05), indicating inferior reinnervation. The axon counts, axon diameter, and G-ratios at the midpart of the conduit or graft demonstrated more axons and lower G-ratios in the autologous graft group. Among the conduit groups, the axon counts were lowest in group B (p < 0.05) followed by group C (p < 0.05). The G-ratio was highest in group B (p < 0.05), although the axon diameter was highest in group B (p < 0.05) as well. CONCLUSIONS Repair of a 10-mm gap in a rodent nerve with an oversized, poorly fitted nerve conduit resulted in tube collapse, poor nerve regenerate, and decreased muscle reinnervation compared with the findings in the animals treated with more accurately fitted nerve conduits. CLINICAL RELEVANCE Accurate sizing of nerve conduits to the nerve-stump diameter improves nerve recovery.
Collapse
Affiliation(s)
- Jonathan Isaacs
- Division of Hand Surgery, Department of Orthopaedic Surgery, Virginia Commonwealth University Medical Center, 1200 East Broad Street, P.O. Box 980153, Richmond, VA 23298. E-mail address for J. Isaacs:
| | - Satya Mallu
- Division of Hand Surgery, Department of Orthopaedic Surgery, Virginia Commonwealth University Medical Center, 1200 East Broad Street, P.O. Box 980153, Richmond, VA 23298. E-mail address for J. Isaacs:
| | - Wo Yan
- Departments of Plastic and Reconstructive Surgery and Anatomy, Shanghai JiaoTong University School of Medicine, Shanghai Ninth People's Hospital, Shanghai 200025, China
| | - Barrett Little
- Division of Hand Surgery, Department of Orthopaedic Surgery, Virginia Commonwealth University Medical Center, 1200 East Broad Street, P.O. Box 980153, Richmond, VA 23298. E-mail address for J. Isaacs:
| |
Collapse
|
14
|
Precisely Assembled Nanofiber Arrays as a Platform to Engineer Aligned Cell Sheets for Biofabrication. Bioengineering (Basel) 2014; 1:114-133. [DOI: 10.3390/bioengineering1030114] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2014] [Revised: 07/09/2014] [Accepted: 07/16/2014] [Indexed: 01/24/2023] Open
|
15
|
Promoting nerve regeneration in a neurotmesis rat model using poly(DL-lactide-ε-caprolactone) membranes and mesenchymal stem cells from the Wharton's jelly: in vitro and in vivo analysis. BIOMED RESEARCH INTERNATIONAL 2014; 2014:302659. [PMID: 25121094 PMCID: PMC4119891 DOI: 10.1155/2014/302659] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2014] [Revised: 05/27/2014] [Accepted: 05/29/2014] [Indexed: 12/17/2022]
Abstract
In peripheral nerves MSCs can modulate Wallerian degeneration and the overall regenerative response by acting through paracrine mechanisms directly on regenerating axons or upon the nerve-supporting Schwann cells. In the present study, the effect of human MSCs from Wharton's jelly (HMSCs), differentiated into neuroglial-like cells associated to poly (DL-lactide-ε-caprolactone) membrane, on nerve regeneration, was evaluated in the neurotmesis injury rat sciatic nerve model. Results in vitro showed successful differentiation of HMSCs into neuroglial-like cells, characterized by expression of specific neuroglial markers confirmed by immunocytochemistry and by RT-PCR and qPCR targeting specific genes expressed. In vivo testing evaluated during the healing period of 20 weeks, showed no evident positive effect of HMSCs or neuroglial-like cell enrichment at the sciatic nerve repair site on most of the functional and nerve morphometric predictors of nerve regeneration although the nociception function was almost normal. EPT on the other hand, recovered significantly better after HMSCs enriched membrane employment, to values of residual functional impairment compared to other treated groups. When the neurotmesis injury can be surgically reconstructed with an end-to-end suture or by grafting, the addition of a PLC membrane associated with HMSCs seems to bring significant advantage, especially concerning the motor function recovery.
Collapse
|
16
|
In vitro biocompatibility and antibacterial efficacy of a degradable poly(L-lactide-co-epsilon-caprolactone) copolymer incorporated with silver nanoparticles. Ann Biomed Eng 2013; 42:1482-93. [PMID: 24150238 DOI: 10.1007/s10439-013-0929-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2013] [Accepted: 10/12/2013] [Indexed: 10/26/2022]
Abstract
Silver nanoparticles (Ag-nps) are currently used as a natural biocide to prevent undesired bacterial growth in clothing, cosmetics and medical products. The objective of the study was to impart antibacterial properties through the incorporation of Ag-nps at increasing concentrations to electrospun degradable 50:50 poly(L-lactide-co-epsilon-caprolactone) scaffolds for skin tissue engineering applications. The biocompatibility of the scaffolds containing Ag-nps was evaluated with human epidermal keratinocytes (HEK); cell viability and proliferation were evaluated using Live/Dead and alamarBlue viability assays following 7 and 14 days of cell culture on the scaffolds. Significant decreases in cell viability and proliferation were noted for the 1.0 mg(Ag) g(scaffold)(-1) after 7 and 14 days on Ag-nps scaffolds. After 14 days, scanning electron microscopy revealed a confluent layer of HEK on the surface of the 0.0 and 0.1 mg(Ag) g(scaffold)(-1). Both 0.5 and 1.0 mg(Ag) g(scaffold)(-1) were capable of inhibiting both Gram positive and negative bacterial strains. Uniaxial tensile tests revealed a significant (p < 0.001) decrease in the modulus of elasticity following Ag-nps incorporation compared to control. These findings suggest that a scaffold containing between 0.5 and 1.0 mg(Ag) g(scaffold)(-1) is both biocompatible and antibacterial, and is suitable for skin tissue engineering graft scaffolds.
Collapse
|
17
|
Siripitayananon J, Molloy R, Bunkird S, Kleawkla A, Panjakha R, Chooprayoon P. Effects of Hot-drawing and Annealing on the Morphology and Mechanical Properties of Biodegradable Polyester Monofilament Fibers. INT POLYM PROC 2013. [DOI: 10.3139/217.2025] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Abstract
Co/terpolymers of L-lactide (LL), ∊-caprolactone (CL) and glycolide (G) are biodegradable in the human body and, as such, have considerable potential for use in biomedical applications such as absorbable surgical sutures, nerve guides, bone fixation devices and drug delivery systems. This study focuses its attention on their potential as monofilament fibers for absorbable suture applications. Random co/terpolymers with different compositions of LL, CL and G were synthesized via bulk ring-opening polymerization. The polymers obtained were melt spun at slow speeds into ice-cooled water to produce as-spun monofilament fibers with as little molecular orientation and crystallinity as possible. Combinations of off-line hot-drawing and annealing steps under controlled conditions of draw rate, draw ratio, temperature and time were then employed in order to develop the fiber's oriented semi-crystalline morphology. The mechanical properties of the fibers were tested after each processing step and compared. The tensile test results showed that the tensile strength was strongly dependent on the draw ratio. A high draw ratio was obtained by multiple off-line hot-drawings with intermediate annealing. The first hot-drawing step dramatically enhanced the mechanical properties relative to those of the weak, highly extensible as-spun fiber. Subsequent annealing at a suitable temperature and for an appropriate length of time increased fiber flexibility as a result of molecular relaxation. Additional hot-drawing steps, again under precise temperature-time conditions, increased the total draw ratio and further enhanced the fiber's mechanical strength.
Collapse
Affiliation(s)
- J. Siripitayananon
- Biomedical Polymers Technology Unit, Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
| | - R. Molloy
- Biomedical Polymers Technology Unit, Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
| | - S. Bunkird
- Biomedical Polymers Technology Unit, Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
| | - A. Kleawkla
- Biomedical Polymers Technology Unit, Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
| | - R. Panjakha
- Biomedical Polymers Technology Unit, Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
| | - P. Chooprayoon
- Biomedical Polymers Technology Unit, Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
| |
Collapse
|
18
|
Yi JS, Lee HJ, Lee HJ, Lee IW, Yang JH. Rat peripheral nerve regeneration using nerve guidance channel by porcine small intestinal submucosa. J Korean Neurosurg Soc 2013; 53:65-71. [PMID: 23560168 PMCID: PMC3611061 DOI: 10.3340/jkns.2013.53.2.65] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2012] [Revised: 11/13/2012] [Accepted: 02/04/2013] [Indexed: 11/27/2022] Open
Abstract
Objective In order to develop a novel nerve guidance channel using porcine small intestinal submucosa (SIS) for nerve regeneration, we investigated the possibility of SIS, a tissue consisting of acellular collagen material without cellular immunogenicity, and containing many kinds of growth factors, as a natural material with a new bioactive functionality. Methods Left sciatic nerves were cut 5 mm in length, in 14 Sprague-Dawley rats. Grafts between the cut nerve ends were performed with a silicone tube (Silicon group, n=7) and rolled porcine SIS (SIS group, n=7). All rats underwent a motor function test and an electromyography (EMG) study on 4 and 10 weeks after grafting. After last EMG studies, the grafts, including proximal and distal nerve segments, were retrieved for histological analysis. Results Foot ulcers, due to hypesthesia, were fewer in SIS group than in Silicon group. The run time tests for motor function study were 2.67 seconds in Silicon group and 5.92 seconds in SIS group. Rats in SIS group showed a better EMG response for distal motor latency and amplitude than in Silicon group. Histologically, all grafts contained some axons and myelination. However, the number of axons and the degree of myelination were significantly higher in SIS group than Silicon group. Conclusion These results show that the porcine SIS was an excellent option as a natural biomaterial for peripheral nerve regeneration since this material contains many kinds of nerve growth factors. Furthermore, it could be used as a biocompatible barrier covering neural tissue.
Collapse
Affiliation(s)
- Jin-Seok Yi
- Department of Neurosurgery, Daejeon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Daejeon, Korea
| | | | | | | | | |
Collapse
|
19
|
Uto K, Muroya T, Okamoto M, Tanaka H, Murase T, Ebara M, Aoyagi T. Design of super-elastic biodegradable scaffolds with longitudinally oriented microchannels and optimization of the channel size for Schwann cell migration. SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS 2012; 13:064207. [PMID: 27877534 PMCID: PMC5099767 DOI: 10.1088/1468-6996/13/6/064207] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2012] [Accepted: 10/03/2012] [Indexed: 06/04/2023]
Abstract
We newly designed super-elastic biodegradable scaffolds with longitudinally oriented microchannels for repair and regeneration of peripheral nerve defects. Four-armed poly(ε-caprolactone-co-D,L-lactide)s (P(CL-co-DLLA)s) were synthesized by ring-opening copolymerization of CL and DLLA from terminal hydroxyl groups of pentaerythritol, and acryloyl chloride was then reacted with the ends of the chains. The end-functionalized P(CL-co-DLLA) was crosslinked in a cylindrical mold in the presence of longitudinally oriented silica fibers as the templates, which were later dissolved by hydrofluoric acid. The elastic moduli of the crosslinked P(CL-co-DLLA)s were controlled between 10-1 and 102 MPa at 37 °C, depending on the composition. The scaffolds could be elongated to 700% of their original size without fracture or damage ('super-elasticity'). Scanning electron microscopy images revealed that well-defined and highly aligned multiple channels consistent with the mold design were produced in the scaffolds. Owing to their elastic nature, the microchannels in the scaffolds did not collapse when they were bent to 90°. To evaluate the effect of the channel diameter on Schwann cell migration, microchannels were also fabricated in transparent poly(dimethylsiloxane), allowing observation of cell migration. The migration speed increased with channel size, but the Young's modulus of the scaffold decreased as the channel diameter increased. These findings may serve as the basis for designing tissue-engineering scaffolds for nerve regeneration and investigating the effects of the geometrical and dimensional properties on axonal outgrowth.
Collapse
Affiliation(s)
- Koichiro Uto
- Biomaterials Unit, International Center for Materials Nanoarchitectonics (WPI-MANA), National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki, 305-0044, Japan
| | - Takanari Muroya
- Biomaterials Unit, International Center for Materials Nanoarchitectonics (WPI-MANA), National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki, 305-0044, Japan
| | - Michio Okamoto
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Osaka, 565-0871, Japan
| | - Hiroyuki Tanaka
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Osaka, 565-0871, Japan
| | - Tsuyoshi Murase
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Osaka, 565-0871, Japan
| | - Mitsuhiro Ebara
- Biomaterials Unit, International Center for Materials Nanoarchitectonics (WPI-MANA), National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki, 305-0044, Japan
| | - Takao Aoyagi
- Biomaterials Unit, International Center for Materials Nanoarchitectonics (WPI-MANA), National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki, 305-0044, Japan
- Department of Materials Engineering, Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8577, Japan
| |
Collapse
|
20
|
Rai R, Tallawi M, Grigore A, Boccaccini AR. Synthesis, properties and biomedical applications of poly(glycerol sebacate) (PGS): A review. Prog Polym Sci 2012. [DOI: 10.1016/j.progpolymsci.2012.02.001] [Citation(s) in RCA: 334] [Impact Index Per Article: 27.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
21
|
Liu BS, Yang YC, Shen CC. Regenerative effect of adipose tissue-derived stem cells transplantation using nerve conduit therapy on sciatic nerve injury in rats. J Tissue Eng Regen Med 2012; 8:337-50. [PMID: 22552954 DOI: 10.1002/term.1523] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2011] [Revised: 09/16/2011] [Accepted: 03/09/2012] [Indexed: 01/13/2023]
Affiliation(s)
- Bai-Shuan Liu
- Department of Medical Imaging and Radiological Sciences; Central Taiwan University of Science and Technology; Taichung Taiwan Republic of China
| | - Yi-Chin Yang
- Department of Neurosurgery; Taichung Veterans General Hospital; Taichung Taiwan Republic of China
| | - Chiung-Chyi Shen
- Department of Neurosurgery; Taichung Veterans General Hospital; Taichung Taiwan Republic of China
- Faculty of Medicine, School of Medicine; National Yang-Ming University; Taipei Taiwan Republic of China
| |
Collapse
|
22
|
Sedaghati T, Yang SY, Mosahebi A, Alavijeh MS, Seifalian AM. Nerve regeneration with aid of nanotechnology and cellular engineering. Biotechnol Appl Biochem 2012; 58:288-300. [PMID: 21995532 DOI: 10.1002/bab.51] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Repairing nerve defects with large gaps remains one of the most operative challenges for surgeons. Incomplete recovery from peripheral nerve injuries can produce a diversity of negative outcomes, including numbness, impairment of sensory or motor function, possibility of developing chronic pain, and devastating permanent disability. In the last few years, numerous microsurgical techniques, such as coaptation, nerve autograft, and different biological or polymeric nerve conduits, have been developed to reconstruct a long segment of damaged peripheral nerve. A few of these techniques are promising and have become popular among surgeons. Advancements in the field of tissue engineering have led to development of synthetic nerve conduits as an alternative for the nerve autograft technique, which is the current practice to bridge nerve defects with gaps larger than 30 mm. However, to date, despite significant progress in this field, no material has been found to be an ideal alternative to the nerve autograft. This article briefly reviews major up-to-date published studies using different materials as an alternative to the nerve autograft to bridge peripheral nerve gaps in an attempt to assess their ability to support and enhance nerve regeneration and their prospective drawbacks, and also highlights the promising hope for nerve regeneration with the next generation of nerve conduits, which has been significantly enhanced with the tissue engineering approach, especially with the aid of nanotechnology in development of the three-dimensional scaffold. The goal is to determine potential alternatives for nerve regeneration and repair that are simply and directly applicable in clinical conditions.
Collapse
Affiliation(s)
- Tina Sedaghati
- UCL Centre for Nanotechnology and Regenerative Medicine, UCL Division of Surgery and Interventional Science, University College London, London, UK
| | | | | | | | | |
Collapse
|
23
|
Shen CC, Yang YC, Liu BS. Peripheral nerve repair of transplanted undifferentiated adipose tissue-derived stem cells in a biodegradable reinforced nerve conduit. J Biomed Mater Res A 2011; 100:48-63. [PMID: 21972223 DOI: 10.1002/jbm.a.33227] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2011] [Revised: 07/04/2011] [Accepted: 08/16/2011] [Indexed: 12/12/2022]
Abstract
This study proposes a biodegradable nerve conduit containing genipin-cross-linked gelatin annexed with tricalcium phosphate ceramic particles (genipin-gelatin-tricalcium phosphate, GGT) in peripheral nerve regeneration. Firstly, cytotoxicity tests revealed that the GGT-extracts were not toxic, and promoted the proliferation and neuronal differentiation of adipose tissue-derived stem cells (ADSCs). Secondly, the GGT composite film effectively supported ADSCs attachment and growth. Additionally, the GGT substrate was biocompatible with the neonatal rat sciatic nerve and produced a beneficial effect on peripheral nerve repair through in vitro tissue culture. Finally, the experiments in this study confirmed the effectiveness of a GGT/ADSCs nerve conduit as a guidance channel for repairing a 10-mm gap in a rat sciatic nerve. Eight weeks after implantation, the mean recovery index of compound muscle action potentials (CMAPs) was significantly different between the GGT/ADSCs and autografts groups (p < 0.05), both of which were significantly superior to the GGT group (p < 0.05). Furthermore, walking track analysis also showed a significantly higher sciatic function index (SFI) score (p < 0.05) and better toe spreading development in the GGT/ADSCs group than in the autograft group. Histological observations and immunohistochemistry revealed that the morphology and distribution patterns of nerve fibers in the GGT/ADSCs nerve conduits were similar to those of the autografts. The GGT nerve conduit offers a better scaffold for the incorporation of seeding undifferentiated ADSCs, and opens a new avenue to replace autologous nerve grafts for the rapid regeneration of damaged peripheral nerve tissues and an improved approach to patient care.
Collapse
Affiliation(s)
- Chiung-Chyi Shen
- Department of Neurosurgery, Taichung Veterans General Hospital, Taichung, Taiwan, Republic of China
| | | | | |
Collapse
|
24
|
Siemionow M, Bozkurt M, Zor F. Regeneration and repair of peripheral nerves with different biomaterials: review. Microsurgery 2011; 30:574-88. [PMID: 20878689 DOI: 10.1002/micr.20799] [Citation(s) in RCA: 136] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Peripheral nerve injury may cause gaps between the nerve stumps. Axonal proliferation in nerve conduits is limited to 10-15 mm. Most of the supportive research has been done on rat or mouse models which are different from humans. Herein we review autografts and biomaterials which are commonly used for nerve gap repair and their respective outcomes. Nerve autografting has been the first choice for repairing peripheral nerve gaps. However, it has been demonstrated experimentally that tissue engineered tubes can also permit lead to effective nerve repair over gaps longer than 4 cm repair that was previously thought to be restorable by means of nerve graft only. All of the discoveries in the nerve armamentarium are making their way into the clinic, where they are, showing great potential for improving both the extent and rate of functional recovery compared with alternative nerve guides.
Collapse
Affiliation(s)
- Maria Siemionow
- Department of Plastic Surgery, The Cleveland Clinic, Cleveland, OH 44195, USA.
| | | | | |
Collapse
|
25
|
Material properties and electrical stimulation regimens of polycaprolactone fumarate-polypyrrole scaffolds as potential conductive nerve conduits. Acta Biomater 2011; 7:944-53. [PMID: 20965280 DOI: 10.1016/j.actbio.2010.10.013] [Citation(s) in RCA: 71] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2010] [Revised: 10/01/2010] [Accepted: 10/12/2010] [Indexed: 11/21/2022]
Abstract
The mechanical and electrical properties of polycaprolactone fumarate-polypyrrole (PCLF-PPy) scaffolds were studied under physiological conditions to evaluate their ability to maintain the material properties necessary for application as conductive nerve conduits. PC12 cells cultured on PCLF-PPy scaffolds were stimulated with regimens of 10 μA of either a constant or a 20 Hz frequency current passed through the scaffolds for 1h per day. PC12 cellular morphologies were analyzed by fluorescence microscopy after 48 h. PCLF-PPy scaffolds exhibited excellent mechanical properties at 37 °C which would allow suturing and flexibility. The surface resistivity of the scaffolds was 2 kΩ and the scaffolds were electrically stable during the application of electrical stimulation (ES). In vitro studies showed significant increases in the percentage of neurite bearing cells, number of neurites per cell and neurite length in the presence of ES compared with no ES. Additionally, extending neurites were observed to align in the direction of the applied current. This study shows that electrically conductive PCLF-PPy scaffolds possess the material properties necessary for application as nerve conduits. Additionally, the capability to significantly enhance and direct neurite extension by passing an electrical current through PCLF-PPy scaffolds renders them even more promising as future therapeutic treatments for severe nerve injuries.
Collapse
|
26
|
Sun M, Kingham PJ, Reid AJ, Armstrong SJ, Terenghi G, Downes S. In vitro and in vivo testing of novel ultrathin PCL and PCL/PLA blend films as peripheral nerve conduit. J Biomed Mater Res A 2010; 93:1470-81. [PMID: 19967758 DOI: 10.1002/jbm.a.32681] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In an attempt to obviate the drawbacks of nerve autograft, ultrathin microporous biodegradable PCL and PCL/PLA films were tested for their compatibility with motor neuron-like NG108-15 cells and primary Schwann cells. Data obtained from MTS colorimetric and DNA fluorimetric assays showed that both cell lines readily attached and proliferated on these materials. Images taken using scanning electron microscope and fluorescence microscope confirmed these observations. Enhanced cell-surface interaction was achieved by pretreating the films in NaOH solution. Importantly, NG108-15 cells could be induced into differentiated phenotype with long, un-branched neurites growing across the surface of the materials. The bipolar spindle-shaped phenotype of Schwann cells was also retained on these scaffolds. Positive immunochemical staining using antibodies against neurofilament for NG108-15 cells and S100 for Schwann cells indicated the expression of these marker proteins. In a small-scaled pilot testing, the performance of PCL conduits in bridging up a 10 mm gap in rat sciatic nerve model was assessed. Immunohistochemical staining showed that regenerated nerve tissue and penetrated Schwann cells have the potential to span the whole length of the conduit in 2 weeks.
Collapse
Affiliation(s)
- M Sun
- Materials Science Centre, Department of Engineering and Physical Sciences, The University of Manchester, Grosvenor Street, Manchester M1 7HS, United Kingdom
| | | | | | | | | | | |
Collapse
|
27
|
Koh HS, Yong T, Teo WE, Chan CK, Puhaindran ME, Tan TC, Lim A, Lim BH, Ramakrishna S. In vivo study of novel nanofibrous intra-luminal guidance channels to promote nerve regeneration. J Neural Eng 2010; 7:046003. [PMID: 20551511 DOI: 10.1088/1741-2560/7/4/046003] [Citation(s) in RCA: 95] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A novel nanofibrous construct for promoting peripheral nerve repair was fabricated and tested in a rat sciatic nerve defect model. The conduit is made out of bilayered nanofibrous membranes with the nanofibers longitudinally aligned in the lumen and randomly oriented on the outer surface. The intra-luminal guidance channel is made out of aligned nanofibrous yarns. In addition, biomolecules such as laminin and nerve growth factor were incorporated in the nanofibrous nerve construct to determine their efficacy in in vivo nerve regeneration. Muscle reinnervation, withdrawal reflex latency, histological, axon density and electrophysiology tests were carried out to compare the efficacy of nanofibrous constructs with an autograft. Our study showed mixed results when comparing the artificial constructs with an autograft. In some cases, the nanofibrous conduit with aligned nanofibrous yarn as an intra-luminal guidance channel performs better than the autograft in muscle reinnervation and withdrawal reflex latency tests. However, the axon density count is highest in the autograft at mid-graft. Functional recovery was improved with the use of the nerve construct which suggested that this nerve implant has the potential for clinical usage in reconstructing peripheral nerve defects.
Collapse
Affiliation(s)
- H S Koh
- NUS Graduate School for Integrative Sciences & Engineering, National University of Singapore, Singapore
| | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Durgam H, Sapp S, Deister C, Khaing Z, Chang E, Luebben S, Schmidt CE. Novel degradable co-polymers of polypyrrole support cell proliferation and enhance neurite out-growth with electrical stimulation. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2010; 21:1265-82. [PMID: 20534184 DOI: 10.1163/092050609x12481751806330] [Citation(s) in RCA: 65] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Synthetic polymers such as polypyrrole (PPy) are gaining significance in neural studies because of their conductive properties. We evaluated two novel biodegradable block co-polymers of PPy with poly(epsilon-caprolactone) (PCL) and poly(ethyl cyanoacrylate) (PECA) for nerve regeneration applications. PPy-PCL and PPy-PECA co-polymers can be processed from solvent-based colloidal dispersions and have essentially the same or greater conductivity (32 S/cm for PPy-PCL, 19 S/cm for PPy-PECA) compared to the PPy homo-polymer (22 S/cm). The PPy portions of the co-polymers permit electrical stimulation whereas the PCL or PECA blocks enable degradation by hydrolysis. For in vitro tests, films were prepared on polycarbonate sheets by air brushing layers of dispersions and pressing the films. We characterized the films for hydrolytic degradation, electrical conductivity, cell proliferation and neurite extension. The co-polymers were sufficient to carry out electrical stimulation of cells without the requirement of a metallic conductor underneath the co-polymer film. In vitro electrical stimulation of PPy-PCL significantly increased the number of PC12 cells bearing neurites compared to unstimulated PPy-PCL. For in vivo experiments, the PPy co-polymers were coated onto the inner walls of nerve guidance channels (NGCs) made of the commercially available non-conducting biodegradable polymer poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHB-HV). The NGCs were implanted in a 10 mm defect made in the sciatic nerve of rats, and harvested after 8 weeks. Histological staining showed axonal growth. The studies indicated that these new conducting degradable biomaterials have good biocompatibility and support proliferation and growth of PC12 cells in vitro (with and without electrical stimulation) and neurons in vivo (without electrical stimulation).
Collapse
Affiliation(s)
- Hymavathi Durgam
- Department of Biomedical Engineering, The University of Texas at Austin, 1 University Station, MC C0800, Austin, TX 78712, USA
| | | | | | | | | | | | | |
Collapse
|
29
|
Sannino A, Silvestri L, Madaghiele M, Harley B, Yannas IV. Modeling the fabrication process of micropatterned macromolecular scaffolds for peripheral nerve regeneration. J Appl Polym Sci 2010. [DOI: 10.1002/app.31715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
30
|
Krych AJ, Rooney GE, Chen B, Schermerhorn TC, Ameenuddin S, Gross L, Moore MJ, Currier BL, Spinner RJ, Friedman JA, Yaszemski MJ, Windebank AJ. Relationship between scaffold channel diameter and number of regenerating axons in the transected rat spinal cord. Acta Biomater 2009; 5:2551-9. [PMID: 19409869 PMCID: PMC2731813 DOI: 10.1016/j.actbio.2009.03.021] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2008] [Revised: 01/20/2009] [Accepted: 03/20/2009] [Indexed: 12/17/2022]
Abstract
Regeneration of endogenous axons through a Schwann cell (SC)-seeded scaffold implant has been demonstrated in the transected rat spinal cord. The formation of a cellular lining in the scaffold channel may limit the degree of axonal regeneration. Spinal cords of adult rats were transected and implanted with the SC-loaded polylactic co-glycollic acid (PLGA) scaffold implants containing seven parallel-aligned channels, either 450mum (n=19) or 660microm in diameter (n=14). Animals were sacrificed after 1, 2 and 3months. Immunohistochemistry for neurofilament expression was performed. The cross-sectional area of fibrous tissue and regenerative core was calculated. We found that the 450microm scaffolds had significantly greater axon fibers per channel at the 1month (186+/-37) and 3month (78+/-11) endpoints than the 660microm scaffolds (90+/-19 and 40+/-6, respectively) (p=0.0164 and 0.0149, respectively). The difference in the area of fibrous rim between the 450 and 660microm channels was most pronounced at the 1month endpoint, at 28,046+/-6551 and 58,633+/-7063microm(2), respectively (p=0.0105). Our study suggests that fabricating scaffolds with smaller diameter channels promotes greater regeneration over larger diameter channels. Axonal regeneration was reduced in the larger channels due to the generation of a large fibrous rim. Optimization of this scaffold environment establishes a platform for future studies of the effects of cell types, trophic factors or pharmacological agents on the regenerative capacity of the injured spinal cord.
Collapse
Affiliation(s)
- Aaron J Krych
- Department of Orthopedic Surgery, Mayo Clinic College of Medicine, Rochester, MN 55905, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
31
|
de Ruiter GCW, Malessy MJA, Yaszemski MJ, Windebank AJ, Spinner RJ. Designing ideal conduits for peripheral nerve repair. Neurosurg Focus 2009; 26:E5. [PMID: 19435445 DOI: 10.3171/foc.2009.26.2.e5] [Citation(s) in RCA: 221] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Nerve tubes, guides, or conduits are a promising alternative for autologous nerve graft repair. The first biodegradable empty single lumen or hollow nerve tubes are currently available for clinical use and are being used mostly in the repair of small-diameter nerves with nerve defects of < 3 cm. These nerve tubes are made of different biomaterials using various fabrication techniques. As a result these tubes also differ in physical properties. In addition, several modifications to the common hollow nerve tube (for example, the addition of Schwann cells, growth factors, and internal frameworks) are being investigated that may increase the gap that can be bridged. This combination of chemical, physical, and biological factors has made the design of a nerve conduit into a complex process that demands close collaboration of bioengineers, neuroscientists, and peripheral nerve surgeons. In this article the authors discuss the different steps that are involved in the process of the design of an ideal nerve conduit for peripheral nerve repair.
Collapse
|
32
|
Meek MF, van der Werff JFA, Klok F, Robinson PH, Nicolai JPA, Gramsbergen A. Functional nerve recovery after bridging a 15 mm gap in rat sciatic nerve with a biodegradable nerve guide. ACTA ACUST UNITED AC 2009; 37:258-65. [PMID: 14649683 DOI: 10.1080/02844310310019464] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Recovery of nerve function was evaluated after bridging a 15 mm sciatic nerve gap in 51 rats with a biodegradable poly(DL-lactide-epsilon-caprolactone) nerve guide. Recovery of function was investigated by analysing the footprints, by analysing video recordings of gait, by electrically eliciting the withdrawal reflex, by nerve conduction velocity and by electromyography (EMG). Sensory nerve function recovered as measured by electrostimulation. Motor nerve function partly recovered but electromyograms remained abnormal throughout the study. We conclude that functional reinnervation by regenerating axons occurs after bridging a 15 mm nerve gap with a biodegradable poly(DL-lactide-epsilon-caprolactone) nerve guide, but the walking patterns remain abnormal. Video analysis is a useful tool to record and analyse the walking patterns of rats. Further studies are necessary to investigate the possibility of obtaining selective reinnervation of specific muscles.
Collapse
Affiliation(s)
- M F Meek
- Department of Plastic Surgery, University Hospital Groningen, Groningen, The Netherlands.
| | | | | | | | | | | |
Collapse
|
33
|
Xiangmei W, Jing Z, Hao C, Qingrui W. Preparation and characterization of collagen-based composite conduit for peripheral nerve regeneration. J Appl Polym Sci 2009. [DOI: 10.1002/app.29811] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
34
|
Cui T, Wang X, Tan Y, Zhang R. Rapid Prototyping a Double-layer Polyurethane—collagen Conduit and its Schwann Cell Compatibility. J BIOACT COMPAT POL 2009. [DOI: 10.1177/0883911509102349] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
A new double-layer conduit that combined an outer synthetic Polyurethane (PU) layer and inner natural collagen layer was fabricated via a double-nozzle low-temperature deposition manufacturing (DLDM) technology. The outer PU layer provided a mechanically stable tunnel against scar tissue invasion in vivo, while the inner collagen layer promoted Schwann cell adhesion, migration, and proliferation. Microporous structures were found in both the layers. A tight connection between the double layers was achieved by adjusting the distance between the two deposit nozzles and adjusting other processing parameters. Schwann cells from rat sciatic nerves were cultured in the layered PU-collagen conduits for one week; a significant enhancement in their retention and viability was seen compared to those made of pure PU. The poly(urethane-collagen) double layer conduit had better Schwann cell compatibility and so has a great potential use in clinical peripheral nerve repair.
Collapse
Affiliation(s)
- Tongkui Cui
- Key Laboratory for Advanced Materials Processing Technology Ministry of Education & Center of Organ Manufacturing Department of Mechanical Engineering, Tsinghua University Beijing 100084, P.R. China
- Institute of Life Science & Medicine Tsinghua University, Beijing 100084, P.R. China
| | - Xlaohong Wang
- Key Laboratory for Advanced Materials Processing Technology Ministry of Education & Center of Organ Manufacturing Department of Mechanical Engineering, Tsinghua University Beijing 100084, P.R. China
- Institute of Life Science & Medicine Tsinghua University, Beijing 100084, P.R. China
| | - Yongnian Tan
- Key Laboratory for Advanced Materials Processing Technology Ministry of Education & Center of Organ Manufacturing Department of Mechanical Engineering, Tsinghua University Beijing 100084, P.R. China
- Institute of Life Science & Medicine Tsinghua University, Beijing 100084, P.R. China
| | - Renji Zhang
- Key Laboratory for Advanced Materials Processing Technology Ministry of Education & Center of Organ Manufacturing Department of Mechanical Engineering, Tsinghua University Beijing 100084, P.R. China
- Institute of Life Science & Medicine Tsinghua University, Beijing 100084, P.R. China
| |
Collapse
|
35
|
de Ruiter GCW, Spinner RJ, Yaszemski MJ, Windebank AJ, Malessy MJA. Nerve tubes for peripheral nerve repair. Neurosurg Clin N Am 2009; 20:91-105, vii. [PMID: 19064182 DOI: 10.1016/j.nec.2008.08.001] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
The concept of the nerve tube has been a major topic of research in the field of peripheral nerve regeneration for more than 25 years. The first nerve tubes are currently available for clinical use. This article gives an overview of the experimental and clinical data on nerve tubes for peripheral nerve repair and critically analyzes the data on which the step from laboratory to clinical use is based. In addition, it briefly discusses the different modifications to the common single lumen nerve tubes that may improve the results of generation.
Collapse
Affiliation(s)
- Godard C W de Ruiter
- Department of Neurosurgery, Leiden University Medical Center, Leiden, The Netherlands
| | | | | | | | | |
Collapse
|
36
|
Battiston B, Raimondo S, Tos P, Gaidano V, Audisio C, Scevola A, Perroteau I, Geuna S. Chapter 11 Tissue Engineering of Peripheral Nerves. INTERNATIONAL REVIEW OF NEUROBIOLOGY 2009; 87:227-49. [DOI: 10.1016/s0074-7742(09)87011-6] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
37
|
Liu BS. Fabrication and evaluation of a biodegradable proanthocyanidin-crosslinked gelatin conduit in peripheral nerve repair. J Biomed Mater Res A 2008; 87:1092-102. [DOI: 10.1002/jbm.a.31916] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
38
|
Prabhakaran MP, Venugopal J, Chan CK, Ramakrishna S. Surface modified electrospun nanofibrous scaffolds for nerve tissue engineering. NANOTECHNOLOGY 2008; 19:455102. [PMID: 21832761 DOI: 10.1088/0957-4484/19/45/455102] [Citation(s) in RCA: 120] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
The development of biodegradable polymeric scaffolds with surface properties that dominate interactions between the material and biological environment is of great interest in biomedical applications. In this regard, poly-ε-caprolactone (PCL) nanofibrous scaffolds were fabricated by an electrospinning process and surface modified by a simple plasma treatment process for enhancing the Schwann cell adhesion, proliferation and interactions with nanofibers necessary for nerve tissue formation. The hydrophilicity of surface modified PCL nanofibrous scaffolds (p-PCL) was evaluated by contact angle and x-ray photoelectron spectroscopy studies. Naturally derived polymers such as collagen are frequently used for the fabrication of biocomposite PCL/collagen scaffolds, though the feasibility of procuring large amounts of natural materials for clinical applications remains a concern, along with their cost and mechanical stability. The proliferation of Schwann cells on p-PCL nanofibrous scaffolds showed a 17% increase in cell proliferation compared to those on PCL/collagen nanofibrous scaffolds after 8 days of cell culture. Schwann cells were found to attach and proliferate on surface modified PCL nanofibrous scaffolds expressing bipolar elongations, retaining their normal morphology. The results of our study showed that plasma treated PCL nanofibrous scaffolds are a cost-effective material compared to PCL/collagen scaffolds, and can potentially serve as an ideal tissue engineered scaffold, especially for peripheral nerve regeneration.
Collapse
|
39
|
de Ruiter GC, Onyeneho IA, Liang ET, Moore MJ, Knight AM, Malessy MJA, Spinner RJ, Lu L, Currier BL, Yaszemski MJ, Windebank AJ. Methods for in vitro characterization of multichannel nerve tubes. J Biomed Mater Res A 2008; 84:643-51. [PMID: 17635012 DOI: 10.1002/jbm.a.31298] [Citation(s) in RCA: 67] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Multichannel conduits have been developed for experimental peripheral nerve and spinal cord repair. We present a series of methods to characterize multichannel nerve tubes for properties of bending, deformation, swelling, and degradation and introduce a new method to test the permeability of multichannel nerve tubes from the rate of diffusion of different-sized fluorescent dextran molecules (10, 40, and 70 kDa). First, single-lumen nerve tubes made with different poly(lactic-co-glycolic acid) (PLGA) ratios (50:50, 75:25, and 85:15) were compared. One ratio (75:25 PLGA) was subsequently used to compare single-lumen and multichannel nerve tubes. Nerve tubes made with lower PLGA ratios were found to be more flexible than nerve tubes made with a higher PLGA ratio. For low ratios, however, swelling was also greater as a result of a faster rate of degradation. Multichannel structure did not interfere with the permeability of the tube; the rate of diffusion into multichannel 75:25 PLGA nerve tubes appeared to be even higher than that into single-lumen ones, but this was only significant for 70-kDa molecules. Also, multichannel 75:25 PLGA nerve tubes were more flexible and, at the same time, more resistant to deformation. However, swelling significantly decreased the total cross-sectional lumen area, especially in multichannel 75:25 PLGA nerve tubes. Permeability, bending, deformation, swelling, and degradation are important properties to characterize in the development of multichannel nerve tubes. The methods presented in this study can be used as a basis for optimizing these properties for future, possibly clinical, application.
Collapse
Affiliation(s)
- Godard C de Ruiter
- Cellular Neurobiology Laboratory, Mayo Clinic, Rochester, Minnesota, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
40
|
Niamsa N, Baimark Y. Synthesis and characterization of poly(L-lactide-co-ϵ-caprolactone)-b-poly(L-lactide) biodegradable diblock copolyesters: Effect of the block lengths on their thermal properties. J Appl Polym Sci 2007. [DOI: 10.1002/app.26993] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
41
|
Kim SM, Lee SK, Lee JH. Peripheral nerve regeneration using a three dimensionally cultured schwann cell conduit. J Craniofac Surg 2007; 18:475-88. [PMID: 17538306 DOI: 10.1097/01.scs.0000249362.41170.f3] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
The use of artificial nerve conduit containing viable Schwann cells is one of the most promising strategies to repair peripheral nerve injury. To fabricate an effective nerve conduit whose microstructure and internal environment are more favorable in nerve regeneration than those currently existing, a new three-dimensional (3D) Schwann cell culture technique using Matrigel and dorsal root ganglion (DRG) was developed. Nerve conduit of 3D arranged Schwann cells was fabricated using direct seeding of freshly harvested DRG into Matrigel-filled silicone tubes (inner diameter 1.98 mm, 14 mm length) and in vitro rafting culture for 2 weeks. The nerve regeneration efficacy of 3D cultured Schwann cell conduit (3D conduit group, n = 6) was assessed using an Sprague-Dawley rat sciatic nerve defect of 10 mm and compared with that of a silicone conduit filled with Matrigel and Schwann cells prepared with the conventional plain culture method (two-dimensional [2D] conduit group, n = 6). After 12 weeks, sciatic function was evaluated with sciatic function index (SFI) and gait analysis, and histomorphology of nerve conduit and the innervated tissues of sciatic nerve were examined using image analyzer and electromicroscopic methods. The SFI and ankle stance angle in the functional evaluation were -60.1 +/- 13.9, 37.9 degrees +/- 5.4 degrees in the 3D conduit group (n = 5) and -87.0 +/- 12.9, 32.2 degrees +/- 4.8 degrees in the 2D conduit group (n = 4). The myelinated axon was 44.91% +/- 0.13% in the 3D conduit group and 13.05% +/- 1.95% in the 2D conduit group. In the transmission electron microscope study, the 3D conduit group showed more abundant myelinated nerve fibers with well-organized and thickened extracellular collagen than the 2D conduit group, and the gastrocnemius muscle and biceps femoris tendon in the 3D conduit group were less atrophied and showed decreased fibrosis with less fatty infiltration than the 2D conduit group. A new 3D Schwann cell culture technique was established, and nerve conduit fabricated using this technique showed much improved nerve regeneration capacity than the silicone tube filled with Matrigel and Schwann cells prepared from the conventional plain culture method.
Collapse
Affiliation(s)
- Soung-Min Kim
- Department of Oral and Maxillofacial Surgery, College of Dentistry, Kangnung National University, Gangneung, South Korea
| | | | | |
Collapse
|
42
|
Chang JY, Lin JH, Yao CH, Chen JH, Lai TY, Chen YS. In Vivo Evaluation of a Biodegradable EDC/NHS-Cross-Linked Gelatin Peripheral Nerve Guide Conduit Material. Macromol Biosci 2007; 7:500-7. [PMID: 17429831 DOI: 10.1002/mabi.200600257] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Peripheral nerve regeneration has been evaluated using a biodegradable nerve conduit, which is made of a 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC)/N-hydroxysuccinimide (NHS) cross-linked gelatin. The EDC/NHS crosslinked gelatin (ENG) conduit is brownish in appearance, and is concentric and round with a smooth outer surface and inner lumen. After subcutaneous implantation on the dorsal side of a rat, the degraded ENG conduit only evoked a mild tissue response, with the formation of a thin tissue capsule surrounding the conduit. Biodegradability of the ENG conduit and its effectiveness as a guidance channel has been examined by its use to repair a 10 mm gap in the rat sciatic nerve. As a result, the tubes degraded throughout the implantation period, but still remained circular with a thin round lumen until they were completely integrated with the enclosed nerves. Successful regeneration through the gap occurred in all the conduits over the three experimental periods of 4, 8, and 12 weeks. Histological observation showed that numerous myelinated axons had crossed through the gap region even at the shortest implantation period of 4 weeks. Peak amplitude, area under the muscle action potential curve, and nerve conductive velocity all showed an increase as a function of the recovery period, which indicates that the nerve had undergone adequate regeneration. These results indicate the superiority of the ENG materials and suggest that the novel ENG conduits provide a promising tool for neuro-regeneration.
Collapse
Affiliation(s)
- Ju-Ying Chang
- Laboratory of Biomaterials, Graduate Institute of Chinese Medical Science, China Medical University, Taichung, Taiwan
| | | | | | | | | | | |
Collapse
|
43
|
Barakat-Walter I, Kraftsik R, Krafsik R, Schenker M, Kuntzer T. Thyroid Hormone in Biodegradable Nerve Guides Stimulates Sciatic Nerve Regeneration: A Potential Therapeutic Approach for Human Peripheral Nerve Injuries. J Neurotrauma 2007; 24:567-77. [PMID: 17402861 DOI: 10.1089/neu.2006.0104] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
It has been already demonstrated that thyroid hormone (T3) is one of the most important stimulating factors in peripheral nerve regeneration. We have recently shown that local administration of T3 in silicon tubes at the level of the transected rat sciatic nerve enhanced axonal regeneration and improved functional recovery. Silicon, however, cannot be used in humans because it causes a chronic inflammatory reaction. Therefore, in order to provide future clinical applications of thyroid hormone in human peripheral nerve lesions, we carried out comparative studies on the regeneration of transected rat sciatic nerve bridged either by biodegradable P(DLLA-(-CL) or by silicon nerve guides, both guides filled with either T3 or phosphate buffer. Our macroscopic observation revealed that 85% of the biodegradable guides allowed the expected regeneration of the transected sciatic nerve. The morphological, morphometric and electrophysiological analysis showed that T3 in biodegradable guides induces a significant increase in the number of myelinated regenerated axons (6862 +/- 1831 in control vs. 11799 +/- 1163 in T3-treated). Also, T3 skewed the diameter of myelinated axons toward larger values than in controls. Moreover, T3 increases the compound muscle action potential amplitude of the flexor and extensor muscles of the treated rats. This T3 stimulation in biodegradable guides was equally well to that obtained by using silicone guides. In conclusion, the administration of T3 in biodegradable guides significantly improves sciatic nerve regeneration, confirming the feasibility of our technique to provide a serious step towards future clinical application of T3 in human peripheral nerve injuries.
Collapse
|
44
|
Xie J, Ihara M, Jung Y, Kwon IK, Kim SH, Kim YH, Matsuda T. Mechano-active scaffold design based on microporous poly(L-lactide-co-epsilon-caprolactone) for articular cartilage tissue engineering: dependence of porosity on compression force-applied mechanical behaviors. ACTA ACUST UNITED AC 2006; 12:449-58. [PMID: 16579678 DOI: 10.1089/ten.2006.12.449] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
An essential component of functional articular cartilage tissue engineering is a mechano-active scaffold, which responds to applied compression stress and causes little permanent deformation. As the first paper of a series on mechano-active scaffold-based cartilage tissue engineering, this study focused on mechanical responses to various modes of loading of compression forces and subsequent selection of mechano-active scaffolds from the biomechanical viewpoint. Scaffolds made of elastomeric microporous poly(L-lactide-co-epsilon-caprolactone) (PLCL) with open-cell structured pores (300 approximately 500 microm) and with different porosities ranging from 71 to 86% were used. The PLCL sponges and rabbit articular cartilage tissue were subjected to compression/unloading tests (0.1 and 0.005 Hz) at 5 kPa, and stress relaxation tests at 10, 30, and 50% strain. The measurements of the maximum strain under loading and residual strain under unloading for compression tests and the maximum stress and equilibrium stress in the stress relaxation test showed that the lower the porosity, the closer the mechanical properties are to those of native cartilage tissue. Among the PLCL sponges, the sponge with 71% porosity appears to be a suitable cartilage scaffold.
Collapse
Affiliation(s)
- Jun Xie
- Division of Biomedical Engineering, Graduate School of Medicine, Kyushu University, Higashi-ku, Fukuoka, Japan
| | | | | | | | | | | | | |
Collapse
|
45
|
Ekholm M, Hietanen J, Tulamo RM, Muhonen J, Lindqvist C, Kellomäki M, Suuronen R. The copolymer of epsilon-caprolactone-lactide and tricalcium phosphate does not enhance bone growth in mandibular defect of sheep. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2006; 17:139-45. [PMID: 16502246 DOI: 10.1007/s10856-006-6817-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2005] [Accepted: 06/28/2005] [Indexed: 05/06/2023]
Abstract
In the field of craniomaxillofacial and orthopaedic surgery there is a constant need for bone or bone substitute. At the present, the most effective way to enhance bone healing clinically is to use autogenous bone grafts. The problems associated with the use of these autografts are donor site morbidity, limited supply and need for a second operative site. Currently there are several different synthetic products commercially available in the market; nevertheless, none of them is ideal for filling bone defects. Therefore, search for new synthetic materials for bone replacement is necessary. A mixture of tricalcium phosphate (TCP) and epsilon-caprolactone-lactide copolymer P(epsilon -CL/DL-LA) was prepared and implanted in critical size mandibular bone defects in twelve sheep. Contralateral side was used as a control. Follow-up times for histological and radiological studies were 9, 14, 24 and 52 weeks. We found that the implanted material did not enhance bone formation compared to control site. We also confirmed that defect size was of critical size, since there was no complete healing of the control site either. The results do not encourage us to continue our studies with the mixture of TCP and P(epsilon-CL/DL-LA) as a filling material for bone defects. Therefore the search for the ideal material is still ongoing.
Collapse
Affiliation(s)
- M Ekholm
- Department of Oral and Maxillofacial Surgery, Helsinki University Central Hospital, Finland
| | | | | | | | | | | | | |
Collapse
|
46
|
Chen MH, Chen PR, Chen MH, Hsieh ST, Huang JS, Lin FH. Anin vivo study of tricalcium phosphate and glutaraldehyde crosslinking gelatin conduits in peripheral nerve repair. J Biomed Mater Res B Appl Biomater 2006; 77:89-97. [PMID: 16211569 DOI: 10.1002/jbm.b.30402] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
In order to modulate the mechanical properties of gelatin, we previously developed a biodegradable composite composed by tricalcium phosphate and glutaraldehyde crosslinking gelatin (GTG) feasible for surgical manipulation. In this study, we evaluated the in vivo applications of GTG conduit for peripheral nerve repair. The effect of sciatic nerve reconstruction was compared between resorbable permeable GTG conduits and durable impermeable silicone tubes. Traditional methods of assessing nerve recovery following peripheral nerve repair including histomorphometric and electrophysiologic features were conducted in our study. In addition, autotomy score and sciatic function index (SFI) in walking tract analysis were used as additional parameters for assessing the return of nerve function. Twenty-four weeks after sciatic nerve repair, the GTG conduits were harvested. Microscopically, regeneration of nerves was observed in the cross-section at the mid portion of all implanted GTG conduits. The cross-sectional area of regenerated nerve of the GTG group was significant larger than that of the silicone group. In the compound muscle action potentials (CMAP), the mean recovery index of CMAP amplitude was 0.24 +/- 0.02 for the silicone group, 0.41 +/- 0.07 for the GTG group. The mean SFI increased with time in the GTG group during the evaluation period until 24 weeks. Walking tract analysis showed a higher SFI score in the GTG group at both 12 and 24 weeks. The difference reached a significant level at 24 weeks. Thus, the histomorphometric, electrophysiologic, and functional assessments demonstrate that GTG can be a candidate for peripheral nerve repair.
Collapse
Affiliation(s)
- Ming-Hong Chen
- Institute of Biomedical Engineering, National Taiwan University, No. 1, Sec. 1, Jen-Ai Road, Taipei, Taiwan
| | | | | | | | | | | |
Collapse
|
47
|
Desouches C, Alluin O, Mutaftschiev N, Dousset E, Magalon G, Boucraut J, Feron F, Decherchi P. La réparation nerveuse périphérique : 30 siècles de recherche. Rev Neurol (Paris) 2005; 161:1045-59. [PMID: 16288170 DOI: 10.1016/s0035-3787(05)85172-0] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
INTRODUCTION Nerve injury compromises sensory and motor functions. Techniques of peripheral nerve repair are based on our knowledge regarding regeneration. Microsurgical techniques introduced in the late 1950s and widely developed for the past 20 years have improved repairs. However, functional recovery following a peripheral mixed nerve injury is still incomplete. STATE OF ART Good motor and sensory function after nerve injury depends on the reinnervation of the motor end plates and sensory receptors. Nerve regeneration does not begin if the cell body has not survived the initial injury or if it is unable to initiate regeneration. The regenerated axons must reach and reinnervate the appropriate target end-organs in a timely fashion. Recovery of motor function requires a critical number of motor axons reinnervating the muscle fibers. Sensory recovery is possible if the delay in reinnervation is short. Many additional factors influence the success of nerve repair or reconstruction. The timing of the repair, the level of injury, the extent of the zone of injury, the technical skill of the surgeon, and the method of repair and reconstruction contribute to the functional outcome after nerve injury. CONCLUSION This review presents the recent advances in understanding of neural regeneration and their application to the management of primary repairs and nerve gaps.
Collapse
Affiliation(s)
- C Desouches
- Service de Chirurgie de la Main, Chirurgie Plastique et Réparatrice des Membres, Assistance Publique, Hôpitaux de Marseille, Hôpital de la Conception, Marseille
| | | | | | | | | | | | | | | |
Collapse
|
48
|
Huang YC, Huang YY, Huang CC, Liu HC. Manufacture of porous polymer nerve conduits through a lyophilizing and wire-heating process. J Biomed Mater Res B Appl Biomater 2005; 74:659-64. [PMID: 15909301 DOI: 10.1002/jbm.b.30267] [Citation(s) in RCA: 54] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
We have developed a method for nerve tissue regeneration using longitudinally oriented channels within biodegradable polymers created by a combined lyophilizing and wire-heating process. This type of cell-adhesive scaffold provides increased area to support and guide extending axons subsequent to nerve injury. Utilizing Ni-Cr wires as mandrels to create channels in scaffold increased safety, effectiveness, and reproducibility. The scaffolds tested were made from different biodegradable polymers, chitosan and poly(D,L-lactide-co-glycolide) (PLGA), because of their availability, ease of processing, low inflammatory response, and approval by the FDA. According to our experimental results, the high permeability and the characteristic porous structure of chitosan proved to be a better material for nerve guidance than PLGA. The scanning electron micrographs revealed that the scaffolds were consistent along the longitudinal axis with channels being distributed evenly throughout the scaffolds. There was no evidence to suggest merging or splitting of individual channels. The diameter of the channels was about 100 mum, similar to the 115 micromameter of the Ni-Cr wire. Regulating the size and quantity of the Ni-Cr wires allow us to control the number and the diameter of the channels. Furthermore, the neutralizing processes significantly influenced the porous structure of chitosan scaffolds. Using weak base (NaHCO(3) 1M) to neutralize chitosan scaffolds made the porous structure more uniform. The innovative method of using Ni-Cr wires as mandrels could be easily tailored to other polymer and solvent systems. The high permeability and the characteristic porous structure of chitosan made it a superior material for nerve tissue engineering. These scaffolds could be useful for guiding regeneration of the peripheral nerve or spinal cord after a transection injury.
Collapse
Affiliation(s)
- Yi-Cheng Huang
- Institute of Biomedical Engineering, College of Engineering, College of Medicine, National Taiwan University, Taipei, Republic of China
| | | | | | | |
Collapse
|
49
|
Baimark Y, Molloy R, Molloy N, Siripitayananon J, Punyodom W, Sriyai M. Synthesis, characterization and melt spinning of a block copolymer of L-lactide and epsilon-caprolactone for potential use as an absorbable monofilament surgical suture. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2005; 16:699-707. [PMID: 15965738 DOI: 10.1007/s10856-005-2605-6] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2004] [Accepted: 12/17/2004] [Indexed: 05/03/2023]
Abstract
This paper describes the synthesis and characterization of a block copolymer of L-lactide (LL) and epsilon -caprolactone (CL) and its subsequent melt spinning into a monofilament fiber. The synthesis reaction was a two-step process. In the first step, an approximately 50:50 mol% random copolymer, P(LL-co-CL), was synthesized via bulk copolymerization of LL and CL. This first-step prepolymer then became the macroinitiator in the second-step reaction in which more LL monomer was added to form a block copolymer, PLL-b-P(LL-co-CL)-b-PLL. Both the prepolymer and block copolymer were characterized by a combination of analytical techniques comprising dilute-solution viscometry, GPC, 1H and 13C NMR, DSC and TG. The block copolymer was then processed into a monofilament fiber using a small-scale melt spinning apparatus. The fiber was spun with a minimum amount of chain orientation and crystallinity so that its semi-crystalline morphology could be constructed under more controlled conditions in subsequent off-line hot-drawing and annealing steps. In this way, the fiber's tensile properties and dimensional stability were developed, as indicated by the changes in its stress-strain curve. The final drawn and annealed fiber had a tensile strength (>400 MPa) approaching that of a commercial PDS II suture of similar size. It is considered that this type of block copolymer has the potential to be developed further as a lower-cost alternative to the current commercial monofilament surgical sutures.
Collapse
Affiliation(s)
- Y Baimark
- Biomedical Polymers Technology Unit, Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand
| | | | | | | | | | | |
Collapse
|
50
|
Kwon IK, Kidoaki S, Matsuda T. Electrospun nano- to microfiber fabrics made of biodegradable copolyesters: structural characteristics, mechanical properties and cell adhesion potential. Biomaterials 2005; 26:3929-39. [PMID: 15626440 DOI: 10.1016/j.biomaterials.2004.10.007] [Citation(s) in RCA: 493] [Impact Index Per Article: 25.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2004] [Accepted: 10/14/2004] [Indexed: 11/17/2022]
Abstract
Nano- to micro-structured biodegradable poly(L-lactide-co-epsilon-caprolactone) (PLCL) fabrics were prepared by electrospinning. Electrospun microfiber fabrics with different compositions of PLCL (mol% in feed; 70/30, 50/50, and 30/70), poly(L-lactide) (PLL) and poly(epsilon-caprolactone) (PCL) were obtained using methylene chloride (MC) as a solvent. The PLL microfiber exhibited a nanoscale-pore structure with a pore diameter of approximately 200-800 nm at the surface and subsurface regions, whereas such a surface structure was hardly observed in other polymers containing CL. The microfiber fabric made of PLCL 50/50 was elastomeric. Nanoscale-fiber fabrics with PLCL 50/50 (approx. 0.3 or 1.2 microm in diameter) were electrospun using 1,1,1,3,3,3-hexafluoro-2-propanol (HFIP) as a solvent. Mercury porosimetry showed that the decrease in the fiber diameter of the fabric decreased porosity, but increased fiber density and mechanical strength. Human umbilical vein endothelial cells (HUVECs) were adhered well and proliferated on the small-diameter-fiber fabrics (0.3 and 1.2 microm in diameter), both of which are dense fabrics, whereas markedly reduced cell adhesion, restricted cell spreading and no signs of proliferation were observed on the large-diameter-fiber fabric (7.0 microm in diameter). The potential biomedical application of electrospun PLCL 50/50 was discussed.
Collapse
Affiliation(s)
- Il Keun Kwon
- Department of Biomedical Engineering, Graduate School of Medicines, Kyushu University, 3-1-1 Maidashi, Higashiku, Fukuoka city, Fukuoka 812-8582, Japan
| | | | | |
Collapse
|