1
|
A'Court JJ, Chatindiara I, Fisher R, Poon PC. Does the stemless reverse arthroplasty compare to a conventional stemmed implant? Clinical and radiographic evaluation at 2 years' minimum follow-up. J Shoulder Elbow Surg 2024; 33:1938-1945. [PMID: 38423251 DOI: 10.1016/j.jse.2024.01.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 01/08/2024] [Accepted: 01/08/2024] [Indexed: 03/02/2024]
Abstract
BACKGROUND Reverse shoulder arthroplasty (RSA) is a well-recognized treatment for many shoulder conditions, including rotator cuff arthropathy, primary glenohumeral joint arthritis, and rheumatoid arthritis, and can be used in both trauma and revision settings. Over the past 10 years, its popularity in New Zealand has been increasing, with a 6%-7% annual growth rate during this period. Stemless RSA designs have the following proposed advantages: They can preserve humeral bone stock, they can limit periprosthetic fractures, and they can be indicated in patients with abnormal diaphyseal humeral anatomy. To date, only 1 study has evaluated the outcomes of the Lima SMR Stemless implant. We present our data with an aim to report how the stemless reverse arthroplasty compares to a conventional stemmed implant. METHODS We performed a retrospective review of a consecutive series of patients treated at a single institution between 2015 and 2020. The endpoint was defined as final follow-up at a minimum of 2 years. Patients were excluded from the final analysis if they underwent revision. Thirty-three patients were identified as having undergone stemless RSA. Thirty patients had patient-reported outcome measures and radiographs at a minimum of 2 years' follow-up. Three patients had undergone revision within 2 years. The same sample size of stemmed RSAs (n = 33) was selected for comparison. RESULTS A total of 60 patients were included in the final analysis, of whom 30 underwent stemless RSA and 30 underwent stemmed RSA. The demographic characteristics of the 2 groups were comparable except age at operation, which showed a statistically significant difference (P = .001): 77 years (stemmed) vs. 65 years (stemless). The mean Oxford Shoulder Score was 40.1 in the stemless group vs. 40 in the stemmed group. The mean American Shoulder and Elbow Surgeons score was 72.9 in the stemless group vs. 79 in the stemmed group. Patient-reported outcome measures, pain scores, and satisfaction ratings were not statistically significantly different between the 2 groups. In terms of radiographic data, subsidence was observed in 2 patients in the stemless RSA group but the patients had no clinical symptoms. Also in the stemless RSA group, 1 patient had an acromial stress fracture and 1 patient had a superficial wound infection successfully treated with oral antibiotics. In terms of revisions in the stemless RSA group, 1 patient underwent revision owing to chronic infection, 1 underwent revision as a result of a periprosthetic fracture after a fall, and 1 underwent revision for gross instability. CONCLUSIONS The early results of sRSA are promising, and the stemless implant shows similar outcomes to a conventional stemmed implant.
Collapse
Affiliation(s)
- Jamie J A'Court
- Department of Orthopaedics, North Shore Hospital, Auckland, New Zealand.
| | - Idah Chatindiara
- Department of Orthopaedics, North Shore Hospital, Auckland, New Zealand
| | - Rachael Fisher
- Department of Orthopaedics, North Shore Hospital, Auckland, New Zealand
| | - Peter C Poon
- Department of Orthopaedics, North Shore Hospital, Auckland, New Zealand
| |
Collapse
|
2
|
Shang G, Xiang S, Guo C, Guo J, Wang P, Wang Y, Xu H. Use of a new off-the-shelf 3D-printed trabecular titanium acetabular cup in Chinese patients undergoing hip revision surgery: Short- to mid-term clinical and radiological outcomes. BMC Musculoskelet Disord 2022; 23:636. [PMID: 35787270 PMCID: PMC9252048 DOI: 10.1186/s12891-022-05596-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Accepted: 06/22/2022] [Indexed: 11/10/2022] Open
Abstract
Background Revision total hip arthroplasty (THA) has been a challenge for surgeons. The purpose of this study was to explore the short-to mid-term clinical and radiological outcomes of Chinese patients who underwent revision THA using a new off-the-shelf three-dimensional (3D)-printed trabecular titanium (TT) acetabular cup by comparison with a conventional porous coated titanium acetabular cup, to provide a reference for the recommendation of this prostheses. Methods A retrospective analysis of 57 patients (57 hips) who received revision THA was performed from January 2016 to June 2019. A total of 23 patients received 3D-printed cups (observation group) and 34 patients received non-3D-printed cups (control group). Clinical scores including Visual Analogue Scale (VAS), Harris Hip Score (HHS) and Short Form 36 (SF-36), upward movement of the hip center of rotation(HCOR)and limb-length discrepancy (LLD), stabilization and bone ingrowth of cups were compared between two groups. The multivariate linear regression was used to determine the factors potentially influencing the HHS score. Postoperative complications in the two groups were also recorded. Results All 57 patients were routinely followed up. The average follow-up durations in the control and observation groups were 43.57 ± 13.68 (24–65) months and 41.82 ± 11.44 (24–64) months, respectively (p = 0.618). The postoperative clinical scores significantly improved in both groups compared to the preoperative scores (p < 0.001). The VAS score did not significantly differ between the groups at 3 (p = 0.946) or 12 (p = 0.681) months postoperatively, or at the last follow-up (p = 0.885). The HHS score did not significantly differ between the groups at 3 months (p = 0.378) postoperatively but differed at 12 months (p < 0.001) postoperatively and the last follow-up (p < 0.001). The SF-36 score did not significantly differ between the groups at 3 months (p = 0.289) postoperatively, but was significantly different at 12 months (p < 0.001) postoperatively and the last follow-up (p < 0.001). Compared with the control group, the postoperative recovery of HCOR and LLD was better in the observation group. All cups remained stable, with no loosening throughout the follow-up period. But the observation group had a significantly better rate of bone ingrowth compared to the control group (p = 0.037). Multivariate linear regression analysis showed that different cup types, upward movement of the HCOR, and LLD influenced the HHS score at the last follow-up (p < 0.001, p = 0.005, respectively). None of the patients exhibited severe postoperative complications. Conclusion The new off-the-shelf 3D-printed TT acetabular cup demonstrated encouraging short-to mid-term clinical outcomes in Chinese patients. It can effectively relieve pain, improve hip function, provide satisfactory biological fixation and high survival rate. But further follow up is necessary to assess its long-term outcomes.
Collapse
Affiliation(s)
- Guangqian Shang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, No. 59, Haier Road, Qingdao, 266000, Shandong, China
| | - Shuai Xiang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, No. 59, Haier Road, Qingdao, 266000, Shandong, China
| | - Cuicui Guo
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, No. 59, Haier Road, Qingdao, 266000, Shandong, China
| | - Jianjun Guo
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, No. 59, Haier Road, Qingdao, 266000, Shandong, China
| | - Peng Wang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, No. 59, Haier Road, Qingdao, 266000, Shandong, China
| | - Yingzhen Wang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, No. 59, Haier Road, Qingdao, 266000, Shandong, China
| | - Hao Xu
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, No. 59, Haier Road, Qingdao, 266000, Shandong, China.
| |
Collapse
|
3
|
Liang D, Song G, Zhang Z. miR‑216a‑3p inhibits osteogenic differentiation of human adipose‑derived stem cells via Wnt3a in the Wnt/β‑catenin signaling pathway. Exp Ther Med 2022; 23:309. [PMID: 35340869 DOI: 10.3892/etm.2022.11238] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Accepted: 01/12/2022] [Indexed: 11/05/2022] Open
Affiliation(s)
- Daning Liang
- Department of Medical Beauty, Shenzhen Hospital (Guangming), University of Chinese Academy of Sciences, Shenzhen, Guangdong 518107, P.R. China
| | - Guodong Song
- Department of Craniomaxillofacial Surgery, Plastic Surgery Hospital of Chinese Academy of Medical Sciences, Beijing 100144, P.R. China
| | - Zhenning Zhang
- Department of Medical Beauty, Shenzhen Hospital (Guangming), University of Chinese Academy of Sciences, Shenzhen, Guangdong 518107, P.R. China
| |
Collapse
|
4
|
Bahraminasab M, Janmohammadi M, Arab S, Talebi A, Nooshabadi VT, Koohsarian P, Nourbakhsh MS. Bone Scaffolds: An Incorporation of Biomaterials, Cells, and Biofactors. ACS Biomater Sci Eng 2021; 7:5397-5431. [PMID: 34797061 DOI: 10.1021/acsbiomaterials.1c00920] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Large injuries to bones are still one of the most challenging musculoskeletal problems. Tissue engineering can combine stem cells, scaffold biomaterials, and biofactors to aid in resolving this complication. Therefore, this review aims to provide information on the recent advances made to utilize the potential of biomaterials for making bone scaffolds and the assisted stem cell therapy and use of biofactors for bone tissue engineering. The requirements and different types of biomaterials used for making scaffolds are reviewed. Furthermore, the importance of stem cells and biofactors (growth factors and extracellular vesicles) in bone regeneration and their use in bone scaffolds and the key findings are discussed. Lastly, some of the main obstacles in bone tissue engineering and future trends are highlighted.
Collapse
Affiliation(s)
- Marjan Bahraminasab
- Department of Tissue Engineering and Applied Cell Sciences, School of Medicine, Semnan University of Medical Sciences, Semnan 3513138111, Iran.,Nervous System Stem Cells Research Center, Semnan University of Medical Sciences, Semnan 3513138111, Iran
| | - Mahsa Janmohammadi
- Department of Biomedical Engineering, Faculty of New Sciences and Technologies, Semnan University, Semnan 3513119111, Iran
| | - Samaneh Arab
- Department of Tissue Engineering and Applied Cell Sciences, School of Medicine, Semnan University of Medical Sciences, Semnan 3513138111, Iran.,Nervous System Stem Cells Research Center, Semnan University of Medical Sciences, Semnan 3513138111, Iran
| | - Athar Talebi
- Nervous System Stem Cells Research Center, Semnan University of Medical Sciences, Semnan 3513138111, Iran
| | - Vajihe Taghdiri Nooshabadi
- Department of Tissue Engineering and Applied Cell Sciences, School of Medicine, Semnan University of Medical Sciences, Semnan 3513138111, Iran.,Nervous System Stem Cells Research Center, Semnan University of Medical Sciences, Semnan 3513138111, Iran
| | - Parisa Koohsarian
- Department of Biochemistry and Hematology, School of Medicine, Semnan University of Medical Sciences, Semnan 3513138111, Iran
| | | |
Collapse
|
5
|
Huang Y, Zhou YX, Tian H, Wang JW, Liu WG, Li H. Minimum 7-year Follow-up of A Porous Coated Trabecular Titanium Cup Manufactured with Electron Beam Melting Technique in Primary Total Hip Arthroplasty. Orthop Surg 2021; 13:817-824. [PMID: 33728818 PMCID: PMC8126901 DOI: 10.1111/os.12846] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2020] [Revised: 09/04/2020] [Accepted: 09/28/2020] [Indexed: 02/06/2023] Open
Abstract
OBJECTIVES To investigate the cup survivorship, patient satisfaction level, clinical function, and radiographic outcomes of patients who underwent total hip arthroplasty (THA) using electron beam melting (EBM)-produced porous coated titanium cups at mid-term follow up. METHODS A total of 32 patients (32 hips) from five hospitals in China who underwent primary THA using EBM-produced trabecular titanium cups between May and December 2012 were retrospectively reviewed. The inclusion criteria were: (i) patients who underwent THA with the use of EBM-produced cups with possible 7-year follow up; and (ii) patients with follow-up information, including the cup survivorship, patient satisfaction level, and clinical outcomes such as Harris hip score. The exclusion criteria were: (i) patients with neuropathic diseases; and (ii) patients who underwent THA due to neoplastic disease. Five (15.6%) patients were lost to follow up before the 7-year follow-up and, thus, were excluded; none of these patients died due to disease associated with the THA or had undergone removal of their cups as of our last evaluation. The mean age and body mass index of the patients were 59.37 (range: 38.00-69.00) years and 24.51 (range: 16.50-34.10) kg/m2 , respectively. Thirteen (48.1%) of the patients were female. RESULTS The average duration of follow-up was 93.48 (range: 89.00-99.00) months. The median Harris hip score improved from 42.00 (interquartile range: 37.00-49.00) to 97.00 (interquartile range: 92.00-97.00) at the latest follow up (P < 0.001). A total of 18 (66.7%) patients rated their satisfaction level as very satisfied, 6 (22.2%) as satisfied, 2 (7.4%) as neutral and 1 (3.7%) as dissatisfied. No intraoperative or postoperative complications were identified. At the latest follow up, all cups were considered to have achieved osteointegration fixation, with three or more of the five signs evident in the most recent X-ray. However, three cups revealed radiolucent lines with a width of less than 1 mm. The median vertical and horizontal distances between the latest postoperative center of rotation relative to the anatomic center of rotation were 2.50 (interquartile range: -3.10, 6.94) mm superiorly and 3.26 (interquartile range: -8.12, 2.38) mm medially, respectively, at the most recent postoperative follow up. Kaplan-Meier survivorship analysis of cups, with the endpoint defined as postoperative radiolucent lines of less than 1 mm in width in at least two zones, reveals that the 8.25-year survival was 96.3% (95% confidence interval: 76.49%-99.47%). CONCLUSION The mid-term follow-up of patients who underwent primary THA using EBM-produced porous coated titanium cups demonstrated favorable patient satisfaction, good clinical function, excellent survivorship, and adequate biological fixation.
Collapse
Affiliation(s)
- Yong Huang
- Department of Orthopaedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Yi-Xin Zhou
- Department of Orthopaedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Hua Tian
- Orthopaedic Department, Peking University Third Hospital, Beijing, China
| | - Jun-Wen Wang
- Department of Orthopaedics and Traumatology, Wuhan Fourth Hospital (Puai Hospital), Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Wen-Guang Liu
- Department of Joint Surgery and Sports Medicine, The Second Hospital of Shandong University, Jinan, China
| | - Hu Li
- Department of Orthopaedic Surgery, Peking University People's Hospital, Beijing, China
| |
Collapse
|
6
|
Perticarini L, Rossi SMP, Medetti M, Benazzo F. Clinical and radiological outcomes of acetabular revision surgery with trabecular titanium cups in Paprosky type II and III bone defects. J Orthop Traumatol 2021; 22:9. [PMID: 33675431 PMCID: PMC7937008 DOI: 10.1186/s10195-021-00571-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Accepted: 02/21/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND This prospective study aims to evaluate the mid-term clinical outcomes and radiographic stability of two different types of cementless trabecular titanium acetabular components in total hip revision surgery. METHODS Between December 2008 and February 2017, 104 cup revisions were performed using trabecular titanium revision cups. Mean age of patients was 70 (range 29-90; SD 11) years. The majority of revisions were performed for aseptic loosening (86 cases, 82.69%), but in all the other diagnoses (18 cases), a significant bone loss (Paprosky type II or III) was registered preoperatively. Bone defects were classified according to Paprosky acetabular classification. We observed 53 type II defects and 42 type III defects. Cups were chosen according to the type of defect. RESULTS Average follow-up was 91 (range 24-146) months. Mean Harris Hip Score (HHS) improved from 43.7 (range 25-70; SD 9) preoperatively to 84.4 (range 46-99; SD 7.56) at last follow-up. One (1.05%) cup showed radiographic radiolucent lines inferior to 2 mm and was clinically asymptomatic. One (1.05%) cup was loose and showed periacetabular allograft reabsorption. Kaplan-Meier survivorship was assessed to be 88.54% (95% CI 80.18-93.52%) at 71 months, with failure of the cup for any reason as the endpoint. CONCLUSION Trabecular titanium revision cups showed good clinical and radiographic results at mid-term follow-up in Paprosky type II and III bone defects. LEVEL OF EVIDENCE Level IV prospective case series.
Collapse
Affiliation(s)
- Loris Perticarini
- Sezione Di Chirurgia Protesica Ad Indirizzo Robotico - Unità Di Traumatologia Dello Sport, U.O. Ortopedia e Traumatologia Fondazione Poliambulanza, Via Bissolati 57, 25124, Brescia, Italy
| | - Stefano Marco Paolo Rossi
- Sezione Di Chirurgia Protesica Ad Indirizzo Robotico - Unità Di Traumatologia Dello Sport, U.O. Ortopedia e Traumatologia Fondazione Poliambulanza, Via Bissolati 57, 25124, Brescia, Italy.
| | - Marta Medetti
- Clinica Ortopedica e Traumatologica, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy
| | - Francesco Benazzo
- Sezione Di Chirurgia Protesica Ad Indirizzo Robotico - Unità Di Traumatologia Dello Sport, U.O. Ortopedia e Traumatologia Fondazione Poliambulanza, Via Bissolati 57, 25124, Brescia, Italy.,Università Degli Studi Di Pavia, Pavia, Italy
| |
Collapse
|
7
|
Ragni E, Perucca Orfei C, Bidossi A, De Vecchi E, Francaviglia N, Romano A, Maestretti G, Tartara F, de Girolamo L. Superior Osteo-Inductive and Osteo-Conductive Properties of Trabecular Titanium vs. PEEK Scaffolds on Human Mesenchymal Stem Cells: A Proof of Concept for the Use of Fusion Cages. Int J Mol Sci 2021; 22:ijms22052379. [PMID: 33673509 PMCID: PMC7956826 DOI: 10.3390/ijms22052379] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 02/19/2021] [Accepted: 02/23/2021] [Indexed: 12/20/2022] Open
Abstract
Fusion cages composed of titanium and its alloys are emerging as valuable alternative to standard polyetheretherketone (PEEK) ones routinely used in cervical and lumbar spine surgery. Aim of this study was to evaluate osteo-inductive and osteo-conductive ability of an innovative trabecular titanium (T-Ti) scaffold on human mesenchymal stem cells (hMSCs), in both absence and presence of biochemical osteogenic stimuli. Same abilities were assessed on PEEK and standard 2D plastic surface, the latter meant as gold-standard for in vitro differentiation studies. hMSCs adhered and colonized both T-Ti and PEEK scaffolds. In absence of osteogenic factors, T-Ti triggered osteogenic induction of MSCs, as demonstrated by alkaline phosphatase activity and calcium deposition increments, while PEEK and standard 2D did not. Addition of osteogenic stimuli reinforced osteogenic differentiation of hMSCs cultured on T-Ti in a significantly higher manner with respect to standard 2D plastic culture surfaces, whereas PEEK almost completely abolished the process. T-Ti driven differentiation towards osteoblasts was confirmed by gene and marker expression analyses, even in absence of osteogenic stimuli. These results clearly indicate superior in vitro osteo-inductive and osteo-conductive capacity of T-Ti compared to PEEK, and make ground for further studies supporting the use of T-Ti cages to improve bone fusion.
Collapse
Affiliation(s)
- Enrico Ragni
- Laboratorio di Biotecnologie Applicate all’Ortopedia, IRCCS Istituto Ortopedico Galeazzi, Via R. Galeazzi 4, I-20161 Milano, Italy; (E.R.); (C.P.O.)
| | - Carlotta Perucca Orfei
- Laboratorio di Biotecnologie Applicate all’Ortopedia, IRCCS Istituto Ortopedico Galeazzi, Via R. Galeazzi 4, I-20161 Milano, Italy; (E.R.); (C.P.O.)
| | - Alessandro Bidossi
- Laboratory of Clinical Chemistry and Microbiology, IRCCS Istituto Ortopedico Galeazzi, Via R. Galeazzi 4, I-20161 Milano, Italy; (A.B.); (E.D.V.)
| | - Elena De Vecchi
- Laboratory of Clinical Chemistry and Microbiology, IRCCS Istituto Ortopedico Galeazzi, Via R. Galeazzi 4, I-20161 Milano, Italy; (A.B.); (E.D.V.)
| | - Natale Francaviglia
- Neurochirurgia Funzionale, Istituto Ortopedico Villa Salus, Contrada Spalla, I-96010 Melilli, Italy;
| | - Alberto Romano
- Unità Operativa di Neurochirurgia, Humanitas Istituto Clinico Catanese, Contrada Cubba Marletta 11, I-95045 Misterbianco, Italy;
| | | | | | - Laura de Girolamo
- Laboratorio di Biotecnologie Applicate all’Ortopedia, IRCCS Istituto Ortopedico Galeazzi, Via R. Galeazzi 4, I-20161 Milano, Italy; (E.R.); (C.P.O.)
- Correspondence: ; Tel.: +39-02-66214059
| |
Collapse
|
8
|
Wang C, Xu D, Li S, Yi C, Zhang X, He Y, Yu D. Effect of Pore Size on the Physicochemical Properties and Osteogenesis of Ti6Al4V Porous Scaffolds with Bionic Structure. ACS OMEGA 2020; 5:28684-28692. [PMID: 33195921 PMCID: PMC7658928 DOI: 10.1021/acsomega.0c03824] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2020] [Accepted: 10/13/2020] [Indexed: 05/08/2023]
Abstract
Ti6Al4V is widely used in implants in the fields of orthopedics and dentistry due to its high compressive strength and good biocompatibility. Nevertheless, Ti6Al4V has a certain degree of biological inertness and the elastic modulus of Ti6Al4V is much higher than the cortex and trabecular bone. In this study, we designed and printed a new type of pore size Ti6Al4V with like-trabecular structure scaffold (the pore size is 800/900/1000 μm, named P8/P9/P10, respectively) with electron beam melting (EBM). Its elastic modulus, compressive strength, and other physical and chemical properties, as well as cell adhesion, proliferation, and differentiation ability and in vitro biological properties were studied. The physical and chemical performance test results showed that as the pore size increased, the surface wettability increased and the elastic modulus decreased. As the pore size increased, F-actin and alkaline phosphatase (ALP) increased significantly, and osteogenesis-related genes including BMP2, OCN, RUNX2, and ALP were upregulated significantly. The reason may be that the components on the Ti6Al4V pore size may have an influence on intracellular signal conversion and then change the mode of cell proliferation and diffusion. In summary, the like-trabecular porous structure can effectively reduce the elastic modulus of metal materials, thereby avoiding stress concentration and promoting the adhesion and proliferation of osteoblasts. Porous materials with larger pores are more conducive to the proliferation and differentiation of osteoblasts. The irregular porous Ti6Al4V scaffold prepared by the EBM technology has good mechanical properties and the potential to promote adhesion, proliferation, and differentiation of osteoblasts, and has the possibility of application in the field of implantation.
Collapse
Affiliation(s)
- Chao Wang
- Guanghua
School of Stomatology, Hospital of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong 510055, China
- Guangdong
Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong 510050, China
| | - Duoling Xu
- Guanghua
School of Stomatology, Hospital of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong 510055, China
- Guangdong
Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong 510050, China
| | - Shujun Li
- Institute
of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China
| | - Chen Yi
- Guanghua
School of Stomatology, Hospital of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong 510055, China
- Guangdong
Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong 510050, China
| | - Xiliu Zhang
- Guanghua
School of Stomatology, Hospital of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong 510055, China
- Guangdong
Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong 510050, China
| | - Yi He
- Guanghua
School of Stomatology, Hospital of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong 510055, China
- Guangdong
Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong 510050, China
| | - Dongsheng Yu
- Guanghua
School of Stomatology, Hospital of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong 510055, China
- Guangdong
Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong 510050, China
| |
Collapse
|
9
|
Osteogenic potential of human adipose derived stem cells (hASCs) seeded on titanium trabecular spinal cages. Sci Rep 2020; 10:18284. [PMID: 33106587 PMCID: PMC7589498 DOI: 10.1038/s41598-020-75385-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Accepted: 10/07/2020] [Indexed: 02/02/2023] Open
Abstract
Spine degenerative conditions are becoming increasingly prevalent, affecting about 5.7% of the population in Europe, resulting in a significant reduction of life's quality. Up to now, many materials have been used in manufacturing cage implants, used as graft substitutes, to achieve immediate and long-term spinal fixation. Particularly, titanium and its alloys are emerging as valuable candidates to develop new types of cages. The aim of this in vitro study was to evaluate the adhesion, proliferation and osteogenic differentiation of adipose derived mesenchymal stem cells (ASCs) seeded on trabecular titanium cages. ASCs adhered, proliferated and produced an abundant extracellular matrix during the 3 weeks of culture. In the presence of osteogenic medium, ASCs differentiated into osteoblast-like cells: the expression of typical bone genes, as well as the alkaline phosphatase activity, was statistically higher than in controls. Furthermore, the dispersive spectrometry microanalysis showed a marked increase of calcium level in cells grown in osteogenic medium. Plus, our preliminary data about osteoinduction suggest that this titanium implant has the potential to induce the ASCs to produce a secretome able to trigger a shift in the ASCs phenotype, possibly towards the osteogenic differentiation, as illustrated by the qRT-PCR and ALP biochemical assay results. The trabecular porous organization of these cages is rather similar to the cancellous bone structure, thus allowing the bone matrix to colonize it efficiently; for these reasons we can conclude that the architecture of this cage may play a role in modulating the osteoinductive capabilities of the implant, thus encouraging its engagement in in vivo studies for the treatment of spinal deformities and diseases.
Collapse
|
10
|
Dall'Ava L, Hothi H, Henckel J, Di Laura A, Shearing P, Hart A. Characterization of dimensional, morphological and morphometric features of retrieved 3D-printed acetabular cups for hip arthroplasty. J Orthop Surg Res 2020; 15:157. [PMID: 32306995 PMCID: PMC7169042 DOI: 10.1186/s13018-020-01665-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Accepted: 04/02/2020] [Indexed: 02/06/2023] Open
Abstract
Background Three-dimensional (3D) printing of porous titanium implants is increasing in orthopaedics, promising enhanced bony fixation whilst maintaining design similarities with conventionally manufactured components. Our study is one of the first to non-destructively characterize 3D-printed implants, using conventionally manufactured components as a reference. Methods We analysed 16 acetabular cups retrieved from patients, divided into two groups: ‘3D-printed’ (n = 6) and ‘conventional’ (n = 10). Coordinate-measuring machine (CMM), electron microscopy (SEM) and microcomputed tomography (micro-CT) were used to investigate the roundness of the internal cup surface, the morphology of the backside surface and the morphometric features of the porous structures of the cups, respectively. The amount of bony attachment was also evaluated. Results CMM analysis showed a median roundness of 19.45 and 14.52 μm for 3D-printed and conventional cups, respectively (p = 0.1114). SEM images revealed partially molten particles on the struts of 3D-printed implants; these are a by-product of the manufacturing technique, unlike the beads shown by conventional cups. As expected, porosity, pore size, strut thickness and thickness of the porous structure were significantly higher for 3D-printed components (p = 0.0002), with median values of 72.3%, 915 μm, 498 μm and 1.287 mm (p = 0.0002). The median values of bony attachment were 84.9% and 69.3% for 3D-printed and conventional cups, respectively (p = 0.2635). Conclusion 3D-printed implants are designed to be significantly more porous than some conventional components, as shown in this study, whilst still exhibiting the same shape and size. We found differences in the surface morphologies of the groups, related to the different manufacturing methods; a key finding was the presence of partially molten particles on the 3D-printed cups.
Collapse
Affiliation(s)
- Lorenzo Dall'Ava
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Brockley Hill, Stanmore, HA7 4LP, UK.
| | - Harry Hothi
- Royal National Orthopaedic Hospital, Stanmore, HA7 4LP, UK
| | - Johann Henckel
- Royal National Orthopaedic Hospital, Stanmore, HA7 4LP, UK
| | - Anna Di Laura
- Royal National Orthopaedic Hospital, Stanmore, HA7 4LP, UK
| | - Paul Shearing
- Electrochemical Innovation Lab, Department of Chemical Engineering, University College London, Torrington Place, London, WC1E 7JE, UK
| | - Alister Hart
- Royal National Orthopaedic Hospital, Stanmore, HA7 4LP, UK
| |
Collapse
|
11
|
Ehlert M, Roszek K, Jędrzejewski T, Bartmański M, Radtke A. Titania Nanofiber Scaffolds with Enhanced Biointegration Activity-Preliminary In Vitro Studies. Int J Mol Sci 2019; 20:E5642. [PMID: 31718064 PMCID: PMC6888681 DOI: 10.3390/ijms20225642] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2019] [Revised: 11/07/2019] [Accepted: 11/09/2019] [Indexed: 12/11/2022] Open
Abstract
The increasing need for novel bone replacement materials has been driving numerous studies on modifying their surface to stimulate osteogenic cells expansion and to accelerate bone tissue regeneration. The goal of the presented study was to optimize the production of titania-based bioactive materials with high porosity and defined nanostructure, which supports the cell viability and growth. We have chosen to our experiments TiO2 nanofibers, produced by chemical oxidation of Ti6Al4V alloy. Fibrous nanocoatings were characterized structurally (X-ray diffraction (XRD)) and morphologically (scanning electron microscopy (SEM)). The wettability of the coatings and their mechanical properties were also evaluated. We have investigated the direct influence of the modified titanium alloy surfaces on the survival and proliferation of mesenchymal stem cells derived from adipose tissue (ADSCs). In parallel, proliferation of bone tissue cells-human osteoblasts MG-63 and connective tissue cells - mouse fibroblasts L929, as well as cell viability in co-cultures (osteoblasts/ADSCs and fibroblasts/ADSCs has been studied. The results of our experiments proved that among all tested nanofibrous coatings, the amorphous titania-based ones were the most optimal scaffolds for the integration and proliferation of ADSCs, fibroblasts, and osteoblasts. Thus, we postulated these scaffolds to have the osteopromotional potential. However, from the co-culture experiments it can be concluded that ADSCs have the ability to functionalize the initially unfavorable surface, and make it suitable for more specialized and demanding cells.
Collapse
Affiliation(s)
- Michalina Ehlert
- Faculty of Chemistry, Nicolaus Copernicus University in Toruń, Gagarina 7, 87-100 Toruń, Poland;
- Nano-Implant Ltd., Gagarina 5/102, 87-100 Toruń, Poland
| | - Katarzyna Roszek
- Faculty of Biological and Veterinary Sciences, Nicolaus Copernicus University in Toruń, Lwowska 1, 87-100 Toruń, Poland; (K.R.); (T.J.)
| | - Tomasz Jędrzejewski
- Faculty of Biological and Veterinary Sciences, Nicolaus Copernicus University in Toruń, Lwowska 1, 87-100 Toruń, Poland; (K.R.); (T.J.)
| | - Michał Bartmański
- Faculty of Mechanical Engineering, Gdańsk University of Technology, Gabriela Narutowicza 11/12, 80-233 Gdańsk, Poland;
| | - Aleksandra Radtke
- Faculty of Chemistry, Nicolaus Copernicus University in Toruń, Gagarina 7, 87-100 Toruń, Poland;
- Nano-Implant Ltd., Gagarina 5/102, 87-100 Toruń, Poland
| |
Collapse
|
12
|
Hong SH, Nam J, Kim HJ, Yoo JJ. Platelet-Rich Plasma Pretreatment on Grit-Blasted Titanium Alloy for Enhanced Osteogenic Differentiation of Human Adipose-Derived Stem Cells. Clin Orthop Surg 2019; 11:361-368. [PMID: 31475059 PMCID: PMC6695324 DOI: 10.4055/cios.2019.11.3.361] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2018] [Accepted: 03/01/2019] [Indexed: 01/09/2023] Open
Abstract
Background Adequate bone formation around titanium alloy implants is integral to successful implantation surgery. Stem cell-coated implants may accelerate peri-implant bone formation. This study investigates the effect of platelet-rich plasma (PRP) pretreatment on a titanium-alloy surface in terms of proliferation and osteogenic differentiation of human adipose-derived stem cells (hADSCs). Methods Allogenic leukocyte-depleted PRP was obtained from blood supernatants. The hADSCs were isolated from thigh subcutaneous fat tissue. Grit-blasted titanium plugs were used in two different groups. In one group, 200 µL of PRP was added to the grit-blasted titanium plugs. The hADSCs were seeded in two groups: grit-blasted titanium plugs with or without PRP. The number of hADSCs was measured after 4 hours, 3 days, and 7 days of culture using Cell Counting Kit-8. Osteogenesis of hADSCs was measured by using an alkaline phosphatase activity assay on days 7 and 14, and a calcium assay on days 14 and 21. Osteogenic gene expression was measured by using reverse transcription polymerase chain reaction analysis of alkaline phosphatase, osteocalcin, and type I collagen mRNA. The microscopic morphology of grit-blasted titanium plugs with or without PRP was examined with a field-emission scanning electron microscope using a JSM-7401F apparatus on days 1 and 7. Results Proliferation and osteogenic differentiation of hADSCs were found to be significantly higher on the grit-blasted titanium alloy preprocessed with PRP than the same alloy without pretreatment. Furthermore, a structural fibrillar mesh developed compactly on the grit-blasted titanium alloy with the PRP pretreatment. Conclusions Our results demonstrate that a hADSC-based approach can be used for tissue-engineered peri-implant bone formation and that PRP pretreatment on the grit-blasted titanium alloy can improve proliferation and osteogenic differentiation of hADSCs.
Collapse
Affiliation(s)
- Seong Hwa Hong
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Korea
| | - Jinwoo Nam
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Korea
| | - Hee Joong Kim
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Korea
| | - Jeong Joon Yoo
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Korea
| |
Collapse
|
13
|
Chiarella E, Aloisio A, Scicchitano S, Lucchino V, Montalcini Y, Galasso O, Greco M, Gasparini G, Mesuraca M, Bond HM, Morrone G. ZNF521 Represses Osteoblastic Differentiation in Human Adipose-Derived Stem Cells. Int J Mol Sci 2018; 19:ijms19124095. [PMID: 30567301 PMCID: PMC6321315 DOI: 10.3390/ijms19124095] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2018] [Revised: 12/11/2018] [Accepted: 12/12/2018] [Indexed: 01/02/2023] Open
Abstract
Human adipose-derived stem cells (hADSCs) are multipotent mesenchymal cells that can differentiate into adipocytes, chondrocytes, and osteocytes. During osteoblastogenesis, the osteoprogenitor cells differentiate into mature osteoblasts and synthesize bone matrix components. Zinc finger protein 521 (ZNF521/Zfp521) is a transcription co-factor implicated in the regulation of hematopoietic, neural, and mesenchymal stem cells, where it has been shown to inhibit adipogenic differentiation. The present study is aimed at determining the effects of ZNF521 on the osteoblastic differentiation of hADSCs to clarify whether it can influence their osteogenic commitment. The enforced expression or silencing of ZNF521 in hADSCs was achieved by lentiviral vector transduction. Cells were cultured in a commercial osteogenic medium for up to 20 days. The ZNF521 enforced expression significantly reduced osteoblast development as assessed by the morphological and molecular criteria, resulting in reduced levels of collagen I, alkaline phosphatase, osterix, osteopontin, and calcium deposits. Conversely, ZNF521 silencing, in response to osteoblastic stimuli, induced a significant increase in early molecular markers of osteogenesis and, at later stages, a remarkable enhancement of matrix mineralization. Together with our previous findings, these results show that ZNF521 inhibits both adipocytic and osteoblastic maturation in hADSCs and suggest that its expression may contribute to maintaining the immature properties of hADSCs.
Collapse
Affiliation(s)
- Emanuela Chiarella
- Department of Clinical and Experimental Medicine, Laboratory of Molecular Haematopoiesis and Stem Cell Biology, University "Magna Græcia", Catanzaro 88100, Italy.
| | - Annamaria Aloisio
- Department of Clinical and Experimental Medicine, Laboratory of Molecular Haematopoiesis and Stem Cell Biology, University "Magna Græcia", Catanzaro 88100, Italy.
| | - Stefania Scicchitano
- Department of Clinical and Experimental Medicine, Laboratory of Molecular Haematopoiesis and Stem Cell Biology, University "Magna Græcia", Catanzaro 88100, Italy.
| | - Valeria Lucchino
- Department of Clinical and Experimental Medicine, Laboratory of Molecular Haematopoiesis and Stem Cell Biology, University "Magna Græcia", Catanzaro 88100, Italy.
- German Center for Neurodegenerative Diseases (DZNE), Bonn 53127, Germany.
| | - Ylenia Montalcini
- Department of Clinical and Experimental Medicine, Laboratory of Molecular Haematopoiesis and Stem Cell Biology, University "Magna Græcia", Catanzaro 88100, Italy.
| | - Olimpio Galasso
- Department of Orthopedic & Trauma Surgery, University "Magna Græcia", Catanzaro 88100, Italy.
| | - Manfredi Greco
- Department of Plastic Surgery, University "Magna Græcia", Catanzaro 88100, Italy.
| | - Giorgio Gasparini
- Department of Orthopedic & Trauma Surgery, University "Magna Græcia", Catanzaro 88100, Italy.
| | - Maria Mesuraca
- Department of Clinical and Experimental Medicine, Laboratory of Molecular Haematopoiesis and Stem Cell Biology, University "Magna Græcia", Catanzaro 88100, Italy.
| | - Heather M Bond
- Department of Clinical and Experimental Medicine, Laboratory of Molecular Haematopoiesis and Stem Cell Biology, University "Magna Græcia", Catanzaro 88100, Italy.
| | - Giovanni Morrone
- Department of Clinical and Experimental Medicine, Laboratory of Molecular Haematopoiesis and Stem Cell Biology, University "Magna Græcia", Catanzaro 88100, Italy.
| |
Collapse
|
14
|
Abstract
Adipose-derived stem/stromal cells (ASCs), together with adipocytes, vascular endothelial cells, and vascular smooth muscle cells, are contained in fat tissue. ASCs, like the human bone marrow stromal/stem cells (BMSCs), can differentiate into several lineages (adipose cells, fibroblast, chondrocytes, osteoblasts, neuronal cells, endothelial cells, myocytes, and cardiomyocytes). They have also been shown to be immunoprivileged, and genetically stable in long-term cultures. Nevertheless, unlike the BMSCs, ASCs can be easily harvested in large amounts with minimal invasive procedures. The combination of these properties suggests that these cells may be a useful tool in tissue engineering and regenerative medicine.
Collapse
Affiliation(s)
- Simone Ciuffi
- Department of Surgery and Translational Medicine, University of Florence, Florence, Italy
| | - Roberto Zonefrati
- Department of Surgery and Translational Medicine, University of Florence, Florence, Italy
| | - Maria Luisa Brandi
- Department of Surgery and Translational Medicine, University of Florence, Florence, Italy
| |
Collapse
|
15
|
Lewallen EA, Jones DL, Dudakovic A, Thaler R, Paradise CR, Kremers HM, Abdel MP, Kakar S, Dietz AB, Cohen RC, Lewallen DG, van Wijnen AJ. Osteogenic potential of human adipose-tissue-derived mesenchymal stromal cells cultured on 3D-printed porous structured titanium. Gene 2016; 581:95-106. [PMID: 26774799 PMCID: PMC5054723 DOI: 10.1016/j.gene.2016.01.015] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2015] [Accepted: 01/12/2016] [Indexed: 01/08/2023]
Abstract
Integration of porous metal prosthetics, which restore form and function of irreversibly damaged joints, into remaining healthy bone is critical for implant success. We investigated the biological properties of adipose-tissue-derived mesenchymal stromal/stem cells (AMSCs) and addressed their potential to alter the in vitro microenvironment of implants. We employed human AMSCs as a practical source for musculoskeletal applications because these cells can be obtained in large quantities, are multipotent, and have trophic paracrine functions. AMSCs were cultured on surgical-grade porous titanium disks as a model for orthopedic implants. We monitored cell/substrate attachment, cell proliferation, multipotency, and differentiation phenotypes of AMSCs upon osteogenic induction. High-resolution scanning electron microscopy and histology revealed that AMSCs adhere to the porous metallic surface. Compared to standard tissue culture plastic, AMSCs grown in the porous titanium microenvironment showed differences in temporal expression for genes involved in cell cycle progression (CCNB2, HIST2H4), extracellular matrix production (COL1A1, COL3A1), mesenchymal lineage identity (ACTA2, CD248, CD44), osteoblastic transcription factors (DLX3, DLX5, ID3), and epigenetic regulators (EZH1, EZH2). We conclude that metal orthopedic implants can be effectively seeded with clinical-grade stem/stromal cells to create a pre-conditioned implant.
Collapse
Affiliation(s)
- Eric A Lewallen
- Department of Orthopedic Surgery, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA
| | - Dakota L Jones
- Department of Orthopedic Surgery, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA; Department of Biomedical Engineering and Physiology, Mayo Graduate School, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA
| | - Amel Dudakovic
- Department of Orthopedic Surgery, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA
| | - Roman Thaler
- Department of Orthopedic Surgery, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA
| | - Christopher R Paradise
- Department of Orthopedic Surgery, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA
| | - Hilal M Kremers
- Department of Health Sciences Research, College of Medicine, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA
| | - Matthew P Abdel
- Department of Orthopedic Surgery, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA
| | - Sanjeev Kakar
- Department of Orthopedic Surgery, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA
| | - Allan B Dietz
- Department of Laboratory Medicine and Pathology, Mayo Clinic, 200 First St. SW Rochester, MN 55905, USA
| | - Robert C Cohen
- Stryker Orthopedics, 325 Corporate Drive, Mahwah, NJ 07430, USA
| | - David G Lewallen
- Department of Orthopedic Surgery, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA.
| | - Andre J van Wijnen
- Department of Orthopedic Surgery, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA; Department of Biomedical Engineering and Physiology, Mayo Graduate School, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA; Department of Biochemistry and Molecular Biology, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA.
| |
Collapse
|
16
|
Perticarini L, Zanon G, Rossi SMP, Benazzo FM. Clinical and radiographic outcomes of a trabecular titanium™ acetabular component in hip arthroplasty: results at minimum 5 years follow-up. BMC Musculoskelet Disord 2015; 16:375. [PMID: 26634830 PMCID: PMC4669605 DOI: 10.1186/s12891-015-0822-9] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2015] [Accepted: 11/19/2015] [Indexed: 01/01/2023] Open
Abstract
Background Aim of this prospective study was to evaluate mid-term clinical and radiographic outcomes in total hip arthroplasty using an acetabular cup made of an innovative biomaterial, Trabecular Titanium™, whose highly porous structure and mechanical properties have been designed to mimic those of the natural bone, thus promoting a more physiological load transfer and a more durable fixation. Methods Between September 2007 and November 2009, 134 total hip replacements and eight revisions were carried out using DELTA-TT primary cups (Lima Corporate, Villanova di San Daniele del Friuli, Italy) in 133 consecutive patients. Mean age was 57.5 ± 14.7 SD (18–92) years. Diagnosis was primarily hip osteoarthritis in 85 (63 %) cases, developmental dysplasia of the hip (DDH) in 24 (18 %) and hip avascular necrosis (AVN) in 10 (7 %). All the revision procedures were due to aseptic loosening of the original implant. Approval of the Institutional Review Board of the IRCCS Policlinico San Matteo in Pavia was obtained for this study. Results Mean follow-up was 72.7 ± 7.9 SD (60–86) months. Average Harris Hip Score (HHS) significantly increased from 44.2 ± 5.4 SD (35–52) preoperatively to 95.9 ± 3.5 SD (88–100) at the last follow-up. No major post-operative complications were observed. 99.3 % of the acetabular components were radiographically stable at the last follow-up, without any radiolucent lines, sclerotic areas or periprosthetic osteolysis. Kaplan-Meier survival rate was 99.3 % at 5 years (95 % confidence interval). Conclusions This first account on the mid-term clinical performance of the DELTA-TT cup shows primary and secondary stability, thus representing an optimal solution for patients with high demands or affected by severe hip conditions.
Collapse
Affiliation(s)
- Loris Perticarini
- Clinica Ortopedica e Traumatologica, Università degli Studi di Pavia, Fondazione IRCCS Policlinico San Matteo, Pavia, Viale Camillo Golgi 19, 27100, Pavia, Italy.
| | - Giacomo Zanon
- Clinica Ortopedica e Traumatologica, Università degli Studi di Pavia, Fondazione IRCCS Policlinico San Matteo, Pavia, Viale Camillo Golgi 19, 27100, Pavia, Italy.
| | - Stefano Marco Paolo Rossi
- Clinica Ortopedica e Traumatologica, Università degli Studi di Pavia, Fondazione IRCCS Policlinico San Matteo, Pavia, Viale Camillo Golgi 19, 27100, Pavia, Italy.
| | - Francesco M Benazzo
- Clinica Ortopedica e Traumatologica, Università degli Studi di Pavia, Fondazione IRCCS Policlinico San Matteo, Pavia, Viale Camillo Golgi 19, 27100, Pavia, Italy.
| |
Collapse
|
17
|
In Vitro Behavior of Human Adipose Tissue-Derived Stem Cells on Poly(ε-caprolactone) Film for Bone Tissue Engineering Applications. BIOMED RESEARCH INTERNATIONAL 2015; 2015:323571. [PMID: 26558266 PMCID: PMC4617699 DOI: 10.1155/2015/323571] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/22/2015] [Accepted: 09/10/2015] [Indexed: 12/12/2022]
Abstract
Bone tissue engineering is an emerging field, representing one of the most exciting challenges for scientists and clinicians. The possibility of combining mesenchymal stem cells and scaffolds to create engineered tissues has brought attention to a large variety of biomaterials in combination with osteoprogenitor cells able to promote and regenerate bone tissue. Human adipose tissue is officially recognized as an easily accessible source of mesenchymal stem cells (AMSCs), a significant factor for use in tissue regenerative medicine. In this study, we analyze the behavior of a clonal finite cell line derived from human adipose tissue seeded on poly(ε-caprolactone) (PCL) film, prepared by solvent casting. PCL polymer is chosen for its good biocompatibility, biodegradability, and mechanical properties. We observe that AMSCs are able to adhere to the biomaterial and remain viable for the entire experimental period. Moreover, we show that the proliferation process and osteogenic activity of AMSCs are maintained on the biofilm, demonstrating that the selected biomaterial ensures cell colonization and the development of an extracellular mineralized matrix. The results of this study highlight that AMSCs and PCL film can be used as a suitable model to support regeneration of new bone for future tissue engineering strategies.
Collapse
|
18
|
Lewallen EA, Riester SM, Bonin CA, Kremers HM, Dudakovic A, Kakar S, Cohen RC, Westendorf JJ, Lewallen DG, van Wijnen AJ. Biological strategies for improved osseointegration and osteoinduction of porous metal orthopedic implants. TISSUE ENGINEERING PART B-REVIEWS 2014; 21:218-30. [PMID: 25348836 DOI: 10.1089/ten.teb.2014.0333] [Citation(s) in RCA: 91] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The biological interface between an orthopedic implant and the surrounding host tissue may have a dramatic effect upon clinical outcome. Desired effects include bony ingrowth (osseointegration), stimulation of osteogenesis (osteoinduction), increased vascularization, and improved mechanical stability. Implant loosening, fibrous encapsulation, corrosion, infection, and inflammation, as well as physical mismatch may have deleterious clinical effects. This is particularly true of implants used in the reconstruction of load-bearing synovial joints such as the knee, hip, and the shoulder. The surfaces of orthopedic implants have evolved from solid-smooth to roughened-coarse and most recently, to porous in an effort to create a three-dimensional architecture for bone apposition and osseointegration. Total joint surgeries are increasingly performed in younger individuals with a longer life expectancy, and therefore, the postimplantation lifespan of devices must increase commensurately. This review discusses advancements in biomaterials science and cell-based therapies that may further improve orthopedic success rates. We focus on material and biological properties of orthopedic implants fabricated from porous metal and highlight some relevant developments in stem-cell research. We posit that the ideal primary and revision orthopedic load-bearing metal implants are highly porous and may be chemically modified to induce stem cell growth and osteogenic differentiation, while minimizing inflammation and infection. We conclude that integration of new biological, chemical, and mechanical methods is likely to yield more effective strategies to control and modify the implant-bone interface and thereby improve long-term clinical outcomes.
Collapse
|
19
|
Skovrlj B, Guzman JZ, Al Maaieh M, Cho SK, Iatridis JC, Qureshi SA. Cellular bone matrices: viable stem cell-containing bone graft substitutes. Spine J 2014; 14:2763-72. [PMID: 24929059 PMCID: PMC4402977 DOI: 10.1016/j.spinee.2014.05.024] [Citation(s) in RCA: 54] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2013] [Revised: 04/03/2014] [Accepted: 05/20/2014] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT Advances in the field of stem cell technology have stimulated the development and increased use of allogenic bone grafts containing live mesenchymal stem cells (MSCs), also known as cellular bone matrices (CBMs). It is estimated that CBMs comprise greater than 17% of all bone grafts and bone graft substitutes used. PURPOSE To critically evaluate CBMs, specifically their technical specifications, existing published data supporting their use, US Food and Drug Administration (FDA) regulation, cost, potential pitfalls, and other aspects pertaining to their use. STUDY DESIGN Areview of literature. METHODS A series of Ovid, Medline, and Pubmed-National Library of Medicine/National Institutes of Health (www.ncbi.nlm.nih.gov) searches were performed. Only articles in English journals or published with English language translations were included. Level of evidence of the selected articles was assessed. Specific technical information on each CBM was obtained by direct communication from the companies marketing the individual products. RESULTS Five different CBMs are currently available for use in spinal fusion surgery. There is a wide variation between the products with regard to the average donor age at harvest, total cellular concentration, percentage of MSCs, shelf life, and cell viability after defrosting. Three retrospective studies evaluating CBMs and fusion have shown fusion rates ranging from 90.2% to 92.3%, and multiple industry-sponsored trials are underway. No independent studies evaluating spinal fusion rates with the use of CBMs exist. All the commercially available CBMs claim to meet the FDA criteria under Section 361, 21 CFR Part 1271, and are not undergoing FDA premarket review. The CBMs claim to provide viable MSCs and are offered at a premium cost. Numerous challenges exist in regard to MSCs' survival, function, osteoblastic potential, and cytokine production once implanted into the intended host. CONCLUSIONS Cellular bone matrices may be a promising bone augmentation technology in spinal fusion surgery. Although CBMs appear to be safe for use as bone graft substitutes, their efficacy in spinal fusion surgery remains highly inconclusive. Large, nonindustry sponsored studies evaluating the efficacy of CBMs are required. Without results from such studies, surgeons must be made aware of the potential pitfalls of CBMs in spinal fusion surgery. With the currently available data, there is insufficient evidence to support the use of CBMs as bone graft substitutes in spinal fusion surgery.
Collapse
Affiliation(s)
- Branko Skovrlj
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, 1 Gustave L Levy Place, Box 1136, New York, NY 10029, USA
| | - Javier Z. Guzman
- Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, 5 East 98th St, 9th Floor, Box 1188, New York, NY 10029, USA
| | - Motasem Al Maaieh
- Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, 5 East 98th St, 9th Floor, Box 1188, New York, NY 10029, USA
| | - Samuel K. Cho
- Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, 5 East 98th St, 9th Floor, Box 1188, New York, NY 10029, USA
| | - James C. Iatridis
- Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, 5 East 98th St, 9th Floor, Box 1188, New York, NY 10029, USA
| | - Sheeraz A. Qureshi
- Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, 5 East 98th St, 9th Floor, Box 1188, New York, NY 10029, USA,Corresponding author. Department of Orthopaedic Surgery, Ichan School of Medicine at Mount Sinai, 5 E. 98th St, Box 1188, New York, NY 10029, USA. Tel.: (212) 241-3909; fax: (212) 534-6202.
| |
Collapse
|
20
|
Abstract
Regenerative medicine is an alternative solution for organ transplantation. Stem cells and nanoscaffolds are two essential components in regenerative medicine. Mesenchymal stem cells (MSCs) are considered as primary adult stem cells with high proliferation capacity, wide differentiation potential, and immunosuppression properties which make them unique for regenerative medicine and cell therapy. Scaffolds are engineered nanofibers that provide suitable microenvironment for cell signalling which has a great influence on cell proliferation, differentiation, and biology. Recently, application of scaffolds and MSCs is being utilized in obtaining more homogenous population of MSCs with higher cell proliferation rate and greater differentiation potential, which are crucial factors in regenerative medicine. In this review, the definition, biology, source, characterization, and isolation of MSCs and current report of application of nanofibers in regenerative medicine in different lesions are discussed.
Collapse
|
21
|
de Peppo GM, Marolt D. Modulating the biochemical and biophysical culture environment to enhance osteogenic differentiation and maturation of human pluripotent stem cell-derived mesenchymal progenitors. Stem Cell Res Ther 2014; 4:106. [PMID: 24004835 PMCID: PMC3854688 DOI: 10.1186/scrt317] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Advances in the fields of stem cell biology, biomaterials, and tissue engineering over the last decades have brought the possibility of constructing tissue substitutes with a broad range of applications in regenerative medicine, disease modeling, and drug discovery. Different types of human stem cells have been used, each presenting a unique set of advantages and limitations with regard to the desired research goals. Whereas adult stem cells are at the frontier of research for tissue and organ regeneration, pluripotent stem cells represent a more challenging cell source for clinical translation. However, with their unlimited growth and wide differentiation potential, pluripotent stem cells represent an unprecedented resource for the construction of advanced human tissue models for biological studies and drug discovery. At the heart of these applications lies the challenge to reproducibly expand, differentiate, and organize stem cells into mature, stable tissue structures. In this review, we focus on the derivation of mesenchymal tissue progenitors from human pluripotent stem cells and the control of their osteogenic differentiation and maturation by modulation of the biophysical culture environment. Similarly to enhancing bone development, the described principles can be applied to the construction of other mesenchymal tissues for basic and applicative studies.
Collapse
|
22
|
Romagnoli C, Brandi ML. Adipose mesenchymal stem cells in the field of bone tissue engineering. World J Stem Cells 2014; 6:144-152. [PMID: 24772241 PMCID: PMC3999772 DOI: 10.4252/wjsc.v6.i2.144] [Citation(s) in RCA: 63] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2013] [Revised: 12/19/2013] [Accepted: 03/04/2014] [Indexed: 02/06/2023] Open
Abstract
Bone tissue engineering represents one of the most challenging emergent fields for scientists and clinicians. Current failures of autografts and allografts in many pathological conditions have prompted researchers to find new biomaterials able to promote bone repair or regeneration with specific characteristics of biocompatibility, biodegradability and osteoinductivity. Recent advancements for tissue regeneration in bone defects have occurred by following the diamond concept and combining the use of growth factors and mesenchymal stem cells (MSCs). In particular, a more abundant and easily accessible source of MSCs was recently discovered in adipose tissue. These adipose stem cells (ASCs) can be obtained in large quantities with little donor site morbidity or patient discomfort, in contrast to the invasive and painful isolation of bone marrow MSCs. The osteogenic potential of ASCs on scaffolds has been examined in cell cultures and animal models, with only a few cases reporting the use of ASCs for successful reconstruction or accelerated healing of defects of the skull and jaw in patients. Although these reports extend our limited knowledge concerning the use of ASCs for osseous tissue repair and regeneration, the lack of standardization in applied techniques makes the comparison between studies difficult. Additional clinical trials are needed to assess ASC therapy and address potential ethical and safety concerns, which must be resolved to permit application in regenerative medicine.
Collapse
|
23
|
Laforenza U, Scaffino MF, Gastaldi G. Aquaporin-10 represents an alternative pathway for glycerol efflux from human adipocytes. PLoS One 2013; 8:e54474. [PMID: 23382902 PMCID: PMC3558521 DOI: 10.1371/journal.pone.0054474] [Citation(s) in RCA: 76] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2012] [Accepted: 12/12/2012] [Indexed: 11/18/2022] Open
Abstract
Background Glycerol outflow from adipocytes has been considered for a decade to be mediated by aquaporin-7, an aquaglyceroporin highly expressed in the adipose tissue. Its involvement in glycerol metabolism has been widely studied also in humans. Recent studies in different aquaporin-7 KO mice models pose two different questions 1) the exact localization of aquaporin-7 in human white adipose tissue; 2) the existence of other aquaglyceroporins that work with aquaporin-7 to guarantee glycerol efflux and thus a normal adiposity in humans. To this purpose we investigated the expression, the localization and the functioning of aquaglyceroporin-10 in subcutaneous white adipose tissue, in isolated and cultured differentiated adipocytes. Methodology/Principal Findings Aquaporin-7 and -10 were expressed in the white adipose tissue both at mRNA and at protein level. Immunofluorescence revealed aquaporin-7 and -10 labelling in the human adipose tissue both to the plasma membrane and to a thin rim of cytoplasm of adipocytes. Aquaporin-7, but not aquaporin-10, colocalized with the endothelial marker CD34. Human cultured differentiated adipocytes showed an aquaporin-7 and -10 labelling mainly in the cytoplasm and in the lipid droplets with insulin reinforcing the lipid droplets staining and isoproterenol inducing its translocation to the plasma membrane compartment. Water and glycerol permeability measurements using adipocytes and adipose membrane vesicles confirmed the presence of functioning aquaglyceroporins. Aquaporin-10 silencing in human differentiated adipocytes resulted in a 50% decrease of glycerol and osmotic water permeability. Conclusions/Significance The results indicate that aquaporin-7, differently from mice, is present in both adipocyte and capillary plasma membranes of human adipose tissue. Aquaporin-10, on the contrary, is expressed exclusively in the adipocytes. The expression of two aquaglyceroporins in human adipose tissue is particularly important for the maintenance of normal or low glycerol contents inside the adipocyte, thus protecting humans from obesity.
Collapse
Affiliation(s)
- Umberto Laforenza
- Department of Molecular Medicine, University of Pavia, Pavia, Italy.
| | | | | |
Collapse
|
24
|
de Peppo GM, Palmquist A, Borchardt P, Lennerås M, Hyllner J, Snis A, Lausmaa J, Thomsen P, Karlsson C. Free-form-fabricated commercially pure Ti and Ti6Al4V porous scaffolds support the growth of human embryonic stem cell-derived mesodermal progenitors. ScientificWorldJournal 2012; 2012:646417. [PMID: 22262956 PMCID: PMC3259715 DOI: 10.1100/2012/646417] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2011] [Accepted: 10/15/2011] [Indexed: 12/14/2022] Open
Abstract
Commercially-pure titanium (cp-Ti) and the titanium-aluminum-vanadium alloy (Ti6Al4V) are widely used as reconstructive implants for skeletal engineering applications, due to their good mechanical properties, biocompatibility and ability to integrate with the surrounding bone. Electron beam melting technology (EBM) allows the fabrication of customized implants with tailored mechanical properties and high potential in the clinical practice. In order to augment the interaction with the biological tissue, stem cells have recently been combined with metallic scaffolds for skeletal engineering applications. We previously demonstrated that human embryonic stem cell-derived mesodermal progenitors (hES-MPs) hold a great potential to provide a homogeneous and unlimited supply of cells for bone engineering applications. This study demonstrates the effect of EBM-fabricated cp-Ti and Ti6Al4V porous scaffolds on hES-MPs behavior, in terms of cell attachment, growth and osteogenic differentiation. Displaying different chemical composition but similar surface properties, EBM-fabricated cp-Ti and Ti6Al4V scaffolds supported cell attachment and growth, and did not seem to alter the expression of genes involved in osteogenic differentiation and affect the alkaline phosphatase activity. In conclusion, interfacing hES-MPs to EBM-fabricated scaffolds may represent an interesting strategy for design of third-generation biomaterials, with the potential to promote implant integration in clinical conditions characterized by poor bone quality.
Collapse
Affiliation(s)
- G M de Peppo
- Department of Biomaterials, Sahlgrenska Academy at University of Gothenburg, P.O. Box 412, 41346 Göteborg, Sweden.
| | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Blanco JF, Sánchez-Guijo FM, Carrancio S, Muntion S, García-Briñon J, del Cañizo MC. Titanium and tantalum as mesenchymal stem cell scaffolds for spinal fusion: an in vitro comparative study. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2011; 20 Suppl 3:353-60. [PMID: 21779858 DOI: 10.1007/s00586-011-1901-8] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2011] [Revised: 03/24/2011] [Accepted: 06/29/2011] [Indexed: 12/11/2022]
Abstract
INTRODUCTION In the last few years, great interest has been focused on tissue engineering as a potential therapeutic approach for musculoskeletal diseases. The role of metallic implants for spinal fusion has been tested in preclinical and clinical settings. Titanium and tantalum have excellent biocompatibility and mechanical properties and are being used in this situation. On the other hand, the therapeutic role of mesenchymal stem cells (MSC) is extensively explored for their multilineage differentiation into osteoblasts. OBJECTIVES In vitro comparison of titanium and tantalum as MSCs scaffolds. MATERIAL AND METHODS In the present study, we have compared the in vitro expansion capacity, viability, immunophenotype (both explored by flow cytometry) and multi-differentiation ability of MSC cultured in the presence of either titanium or tantalum fragments. The adherence of MSC to either metal was demonstrated by electron microscopy. RESULTS Both metals were able to carry MSC when transferred to new culture flasks. In addition, our study shows that culture of MSC with titanium or tantalum improves cell viability and maintains all their biological properties, with no significant differences regarding the metal employed. CONCLUSION This would support the use of these combinations for clinical purposes, especially in the spinal fusion and reconstruction setting.
Collapse
Affiliation(s)
- Juan F Blanco
- Department of Orthopedics, Servicio de Traumatología y CO, Hospital Universitario de Salamanca, Paseo de San Vicente 58, 37007, Salamanca, Spain.
| | | | | | | | | | | |
Collapse
|
26
|
Abstract
This is a review of the growing scientific interest in the developmental plasticity and therapeutic potential of stromal cells isolated from adipose tissue. Adipose-derived stem/stromal cells (ASCs) are multipotent somatic stem cells that are abundant in fat tissue. It has been shown that ASCs can differentiate into several lineages, including adipose cells, chondrocytes, osteoblasts, neuronal cells, endothelial cells, and cardiomyocytes. At the same time, adipose tissue can be harvested by a minimally invasive procedure, which makes it a promising source of adult stem cells. Therefore, it is believed that ASCs may become an alternative to the currently available adult stem cells (e.g. bone marrow stromal cells) for potential use in regenerative medicine. In this review, we present the basic information about the field of adipose-derived stem cells and their potential use in various applications.
Collapse
|
27
|
Stem Cells Grown in Osteogenic Medium on PLGA, PLGA/HA, and Titanium Scaffolds for Surgical Applications. Bioinorg Chem Appl 2010:831031. [PMID: 21234383 PMCID: PMC3017899 DOI: 10.1155/2010/831031] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2010] [Revised: 09/15/2010] [Accepted: 10/27/2010] [Indexed: 12/17/2022] Open
Abstract
Pluripotent adipose tissue-derived stem cells (hASCs) can differentiate into various mesodermal cell types such as osteoblasts, chondroblasts, and myoblasts. We isolated hASCs from subcutaneous adipose tissue during orthopaedic surgery and induced the osteogenic differentiation for 28 days on three different synthetic scaffolds such as polylactide-co-glycolide (PLGA), polylactide-co-glycolide/hydroxyapatite (PLGA/HA), and trabecular titanium scaffolds (Ti6Al4V). Pore size can influence certain criteria such as cell attachment, infiltration, and vascularization. The aim of this study was to investigate the performance of PLGA and PLGA/HA scaffolds with a higher porosity, ranging between 75% and 84%, with respect to Ti scaffolds but with smaller pore size, seeded with hASCs to develop a model that could be used in the treatment of bone defects and fractures. Osteogenesis was assessed by ELISA quantitation of extracellular matrix protein expression, von Kossa staining, X-ray microanalysis, and scanning electron microscopy. The higher amount of protein matrix on the Ti scaffold with respect to PLGA and PLGA/HA leads to the conclusion that not only the type of material but the structure significantly affects cell proliferation.
Collapse
|