1
|
Bettenfeld R, Claudel J, Kourtiche D, Nadi M, Schlauder C. Design and Modeling of a Device Combining Single-Cell Exposure to a Uniform Electrical Field and Simultaneous Characterization via Bioimpedance Spectroscopy. SENSORS (BASEL, SWITZERLAND) 2023; 23:3460. [PMID: 37050519 PMCID: PMC10098563 DOI: 10.3390/s23073460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 03/17/2023] [Accepted: 03/23/2023] [Indexed: 06/19/2023]
Abstract
Previous studies have demonstrated the electropermeabilization of cell membranes exposed to an electric field with moderate intensity (<2 V/cm) and a frequency of <100 MHz. Bioimpedance spectroscopy (BIS) is an electrical characterization technique that can be useful in studying this phenomenon because it is already used for electroporation. In this paper, we report a device designed to perform BIS on single cells and expose them to an electric field simultaneously. It also allows cells to be monitored by visualization through a transparent exposure electrode. This device is based on a lab-on-a-chip (LOC) with a microfluidic cell-trapping system and microelectrodes for BIS characterization. We present numerical simulations that support the design of the LOC. We also describe the fabrication of the LOC and the first electrical characterization of its measurement bandwidth. This first test, performed on reference medium with a conductivity in the same order than human cells, confirms that the measurement capabilities of our device are suitable for electrical cells characterization.
Collapse
|
2
|
Prestat M, Thierry D. Corrosion of titanium under simulated inflammation conditions: clinical context and in vitro investigations. Acta Biomater 2021; 136:72-87. [PMID: 34626820 DOI: 10.1016/j.actbio.2021.10.002] [Citation(s) in RCA: 41] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 09/15/2021] [Accepted: 10/01/2021] [Indexed: 01/01/2023]
Abstract
Titanium and alloys thereof are widely utilized for biomedical applications in the fields of orthopedics and dentistry. The corrosion resistance and perceived biocompatibility of such materials are essentially related to the presence of a thin passive oxide layer on the surface. However, during inflammation phases, the immune system and its leukocytic cells generate highly aggressive molecules, such as hydrogen peroxide and radicals, that can significantly alter the passive film resulting in the degradation of the titanium implants. In combination with mechanical factors, this can lead to the release of metal ions, nanoparticles or microscaled debris in the surrounding tissues (which may sustain chronic inflammation), bring about relevant health issues and contribute to implant loss or failure. After briefly presenting the context of inflammation, this review article analyses the state-of-the-art knowledge of the in vitro corrosion of titanium, titanium alloys and coated titanium by reactive oxygen species and by living cells with an emphasis on electrochemical and microstructural aspects. STATEMENT OF SIGNIFICANCE: Inflammation involves the production of reactive oxygen species that are known to alter the passive layer protecting titanium implants against the aggressive environment of the human body. Inflammatory processes therefore contribute to the deterioration of biomedical devices. Although review articles on biomaterials for implant applications are regularly published in the literature, none has ever focused specifically on the topic of inflammation. After briefly recalling the clinical context, this review analyses the in vitro studies on titanium corrosion under simulated inflammation conditions from the pioneer works of the 80s and the 90s till the most recent investigations. It reports about the status of this research area for a multidisciplinary readership covering the fields of materials science, corrosion and implantology.
Collapse
Affiliation(s)
- M Prestat
- French Corrosion Institute - RISE, 220 rue Pierre Rivoalon, 29200 Brest, France.
| | - D Thierry
- French Corrosion Institute - RISE, 220 rue Pierre Rivoalon, 29200 Brest, France; Research Institutes of Sweden (RISE), Stockholm, Sweden
| |
Collapse
|
3
|
Chen W, Zhu WQ, Qiu J. Impact of exogenous metal ions on peri-implant bone metabolism: a review. RSC Adv 2021; 11:13152-13163. [PMID: 35423842 PMCID: PMC8697588 DOI: 10.1039/d0ra09395e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 03/25/2021] [Indexed: 11/21/2022] Open
Abstract
The development of effective methods to promote the osseointegration of dental implants by surface modification is an area of intense research in dental materials science. Exogenous metal ions present in the implant and surface modifications are closely related to the bone metabolism around the implant. In the complex oral microenvironment, the release of metal ions caused by continuous corrosion of dental implants has an unfavorable impact on the surrounding tissue, and then affects osseointegration, leading to bad results such as loosening and falling off in the late stage of the implant. Besides, these ions can even be distributed in distant tissues and organs. Currently, surface modification techniques are being developed that involve different processing technologies including the introduction of exogenous metal ions with different properties onto the surface of implants to improve performance. However, most metal elements have some level of biological toxicity and can only be used within a safe concentration range to exert the optimum biological effects on recipients. In this paper, we review the adverse effects of metal ions on osseointegration and highlight the emerging applications for metal elements in improving the performance of dental implants.
Collapse
Affiliation(s)
- Wei Chen
- Department of Oral Implantology, Affiliated Hospital of Stomatology, Nanjing Medical University Nanjing 210029 PR China +86 25 69593085
- Jiangsu Key Laboratory of Oral Disease, Nanjing Medical University Nanjing 210029 PR China
| | - Wen-Qing Zhu
- Department of Oral Implantology, Affiliated Hospital of Stomatology, Nanjing Medical University Nanjing 210029 PR China +86 25 69593085
- Jiangsu Key Laboratory of Oral Disease, Nanjing Medical University Nanjing 210029 PR China
| | - Jing Qiu
- Department of Oral Implantology, Affiliated Hospital of Stomatology, Nanjing Medical University Nanjing 210029 PR China +86 25 69593085
- Jiangsu Key Laboratory of Oral Disease, Nanjing Medical University Nanjing 210029 PR China
| |
Collapse
|
4
|
Zhu WQ, Ming PP, Zhang SM, Qiu J. Role of MAPK/JNK signaling pathway on the regulation of biological behaviors of MC3T3‑E1 osteoblasts under titanium ion exposure. Mol Med Rep 2020; 22:4792-4800. [PMID: 33173964 PMCID: PMC7646925 DOI: 10.3892/mmr.2020.11575] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Accepted: 08/18/2020] [Indexed: 12/13/2022] Open
Abstract
The oral cavity is a complex environment that is constantly undergoing remodeling. This provides a favorable electrolytic aqueous condition, which causes the corrosion of titanium implants and the release of titanium (Ti) ions. The accumulation of Ti ions in the peri-implant tissues may affect the osteogenesis process. Therefore, the present study aimed to investigate the possible effects of Ti ions on osteoblast physiology and its underlying mechanism, specifically the MAPK/JNK signaling pathway. In the present study, MC3T3-E1 osteoblasts were cultured the medium containing 10 ppm Ti ions. Confocal laser scanning microscopy was used to analyze cell morphology and adhesion. Alkaline phosphatase (ALP) activity assay and western blotting were performed to evaluate the expression of proteins associated with osteogenesis such as Runx2 and Osterix. Nuclear translocation of JNK, a key factor of the MAPK signaling pathway, was visualized and analyzed using immunofluorescence staining. The results showed that 10 ppm Ti ions exerted negative effects on the biological behaviors of MC3T3-E1 cells, which exhibited reduced adhesion, ALP activity and osteogenic differentiation. It was also found that 10 ppm Ti ions activated the MAPK/JNK signaling pathway by promoting the nuclear translocation of JNK via phosphorylation. In addition, the inhibitory effects of 10 ppm Ti ions on MC3T3-E1 cells was found to be reversed by the JNK inhibitor SP600125. In conclusion, the preset study suggests that the MAPK/JNK signaling pathway serves a key role in the molecular mechanism underlying the changes in osteoblast behavior following Ti ion exposure. These findings may serve as a valuable reference point for the further in-depth exploration of peri-implant bone loss.
Collapse
Affiliation(s)
- Wen-Qing Zhu
- Department of Oral Implantology, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Pan-Pan Ming
- Department of Stomatology, Sir Run Run Hospital, Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Song-Mei Zhang
- Department of General Dentistry, Eastman Institute for Oral Health, University of Rochester, Rochester, NY 14620, USA
| | - Jing Qiu
- Department of Oral Implantology, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| |
Collapse
|
5
|
Radice S, Westrick J, Ebinger K, Mathew MT, Wimmer MA. In-vitro studies on cells and tissues in tribocorrosion processes: A systematic scoping review. ACTA ACUST UNITED AC 2020; 24. [PMID: 33015276 DOI: 10.1016/j.biotri.2020.100145] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Tribocorrosion of implants has been widely addressed in the orthopedic and dental research fields. This study is a systematic scoping review about research methods that combine tribocorrosion tests with cells/tissues cultures, aimed to identify related current problems and future challenges. We used 4 different databases to identify 1022 records responding to an articulated keywords search-strategy. After removing the duplicates and the articles that didn't meet the search-criteria, we assessed 20 full-text articles for eligibility. Of the 20 eligible articles, we charted 8 records on cell cultures combined with tribocorrosion tests on implant materials (titanium, CoCrMo, and/or stainless steel). The year of publication ranged from 1991 to 2019. The cell line used was mostly murine. Two records used fretting tests, while 6 used reciprocating sliding with pin-on-disc tribometers. An electrochemical three-electrode setup was used in 4 records. We identified overall two experimental approaches: cells cultured on the metal (5 records), and cells cultured near the metal (3 records). Research activities on tribocorrosion processes in the presence of cells have been undertaken worldwide by a few groups. After a limited initial interest on this topic in the 1990's, research activities have restarted in the last decade, renewing the topic with technologically more advanced setups and analytical tools. We identified the main problems to be the lack of test reproducibility and wear particle characterization. We believe that the main challenges lay in the interdisciplinary approach, the inter-laboratory validation of experiments, and the interpretation of results, particularly in relation to potential clinical significance.
Collapse
Affiliation(s)
- S Radice
- Rush University Medical Center, Department of Orthopedic Surgery, 1611 W. Harrison St., Chicago, IL 60612, USA
| | - J Westrick
- Library of Rush University Medical Center, 600 S. Paulina St., Chicago, IL 60612, USA
| | - K Ebinger
- Klinikum Garmisch-Partenkirche, Auenstraße 6, 82467 Garmisch-Partenkirchen, Germany
| | - M T Mathew
- College of Medicine at Rockford, University of Illinois, Department of Biomedical Sciences, 1601 Parkview Avenue, Rockford, IL 61107, USA
| | - M A Wimmer
- Rush University Medical Center, Department of Orthopedic Surgery, 1611 W. Harrison St., Chicago, IL 60612, USA
| |
Collapse
|
6
|
Comparison between Plasma Electrolytic Oxidation Coating and Sandblasted Acid-Etched Surface Treatment: Histometric, Tomographic, and Expression Levels of Osteoclastogenic Factors in Osteoporotic Rats. MATERIALS 2020; 13:ma13071604. [PMID: 32244631 PMCID: PMC7178360 DOI: 10.3390/ma13071604] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/08/2020] [Revised: 03/11/2020] [Accepted: 03/13/2020] [Indexed: 02/06/2023]
Abstract
Plasma electrolytic oxidation (PEO) has been a promising surface coating with better mechanical and antimicrobial parameters comparing to conventional treatment surfaces. This study evaluated the peri-implant bone repair using (PEO) surface coatings compared with sandblasted acid (SLA) treatment. For this purpose, 44 Wistar rats were ovariectomized (OVX-22 animals) or underwent simulated surgery (SS-22 animals) and received implants in the tibia with each of the surface coatings. The peri-implant bone subsequently underwent molecular, microstructural, bone turnover, and histometric analysis. Real-time PCR showed a higher expression of osteoprotegerin (OPG), receptor activator of nuclear kappa-B ligand (RANKL), and osteocalcin (OC) proteins in the SLA/OVX and PEO/SS groups (p < 0.05). Computed microtomography, confocal microscopy, and histometry showed similarity between the PEO and SLA surfaces, with a trend toward the superiority of PEO in OVX animals. Thus, PEO surfaces were shown to be promising for enhancing peri-implant bone repair in ovariectomized rats.
Collapse
|
7
|
Al Otaibi A, Sherif ESM, Al-Rifaiy MQ, Zinelis S, Al Jabbari YS. Corrosion resistance of coupled sandblasted, large-grit, acid-etched (SLA) and anodized Ti implant surfaces in synthetic saliva. Clin Exp Dent Res 2019; 5:452-459. [PMID: 31687177 PMCID: PMC6820584 DOI: 10.1002/cre2.198] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Revised: 02/16/2019] [Accepted: 02/18/2019] [Indexed: 11/17/2022] Open
Abstract
Purpose The purpose of this study was to investigate the corrosion resistance of galvanically coupled SLA and anodized implant surfaces with a Co‐Cr alloy. Materials and Methods Three groups were included in this study. The first (SLA) was composed of SLA implants (Institut Straumann, Basel, Switzerland), the second (ANO) of NobelReplace® (Nobel Biocare, Göteborg, Sweden), and the third (MIX) of both implant systems combined. All groups were assembled with a single Co‐Cr superstructure. Electrochemical testing included open‐circuit potential, electrochemical impedance spectroscopy, cyclic potentiodynamic polarization, and chronoamperometric current‐time measurements. The quantitative results (EOCP, ECORR, ICORR, EPROT, RP, and ICA) were statistically analyzed by one‐way ANOVA and Tukey's post‐hoc multiple comparison test (α = 0.05) Results All the aforementioned parameters showed statistically significant differences apart from ECORR and EPROT. The evaluation of qualitative and quantitative results showed that although SLA had higher corrosion resistance compared with ANO, it had less resistance to pitting corrosion. This means that SLA showed increased resistance to uniform corrosion but less resistance if pitting corrosion was initiated. In all cases, MIX showed intermediate behavior. Conclusion The corrosion resistance of implant‐retained superstructures is dependent on the electrochemical properties of the implants involved, and thus different degrees of intraoral corrosion resistance among different implant systems are anticipated.
Collapse
Affiliation(s)
- Ala'a Al Otaibi
- Dental Biomaterials Research and Development Chair, College of Dentistry King Saud University Riyadh Saudi Arabia.,Department of Prosthetic Dental Science, College of Dentistry King Saud University Riyadh Saudi Arabia
| | - El-Sayed M Sherif
- Dental Biomaterials Research and Development Chair, College of Dentistry King Saud University Riyadh Saudi Arabia.,Center of Excellence for Research in Engineering Materials (CEREM) King Saud University Riyadh Saudi Arabia.,Electrochemistry and Corrosion Laboratory, Department of Physical Chemistry National Research Centre (NRC) Cairo Egypt
| | - Mohammed Q Al-Rifaiy
- Dental Biomaterials Research and Development Chair, College of Dentistry King Saud University Riyadh Saudi Arabia.,Department of Prosthetic Dental Science, College of Dentistry King Saud University Riyadh Saudi Arabia
| | - Spiros Zinelis
- Department of Biomaterials, School of Dentistry National and Kapodistrian University of Athens Athens Greece.,Dental Biomaterials Research and Development Chair, College of Dentistry King Saud University Riyadh Saudi Arabia
| | - Youssef S Al Jabbari
- Dental Biomaterials Research and Development Chair, College of Dentistry King Saud University Riyadh Saudi Arabia.,Department of Prosthetic Dental Science, College of Dentistry King Saud University Riyadh Saudi Arabia
| |
Collapse
|
8
|
Concentrate Growth Factors Regulate Osteogenic Dysfunction of MC3T3-E1 Cells Induced by High Glucose Through PI3K/Akt Signaling Pathway. IMPLANT DENT 2019; 28:478-483. [PMID: 31241545 DOI: 10.1097/id.0000000000000921] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
INTRODUCTION The aim of this study is to investigate the effects of Concentrate Growth Factors Extract (CGF-e) on the proliferation and osteogenic differentiation of MC3T3-E1 cells under high glucose condition. MATERIALS AND METHODS MC3T3-E1 cells were divided into 4 groups including normal glucose (5.5-mM) group (control), high glucose (25.5-mM) group, normal glucose + CGF-e group, and high glucose + CGF-e group. The proliferation, osteogenic differentiation and mineralization of osteoblasts were evaluated, respectively, by the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) assay, cytoskeleton analysis, alkaline phosphatase activity assay, alizarin red staining, and real-time polymerase chain reaction. Western blots analysis was used to explore the role of PI3K/Akt pathway. RESULTS The viability, osteogenic differentiation, and mineralization of MC3T3-E1 cells were significantly decreased by high glucose. All observed osteogenic dysfunction were inhibited by CGF-e. Moreover, the PI3K/Akt pathway was activated by CGF-e. CONCLUSIONS It was concluded that the soluble factors released by CGF could significantly attenuate high glucose-mediated MC3T3-E1 cells osteogenic dysfunction through the PI3K/Akt pathway.
Collapse
|
9
|
Enhanced corrosion resistance of zinc-containing nanowires-modified titanium surface under exposure to oxidizing microenvironment. J Nanobiotechnology 2019; 17:55. [PMID: 30992009 PMCID: PMC6466780 DOI: 10.1186/s12951-019-0488-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Accepted: 04/09/2019] [Indexed: 12/19/2022] Open
Abstract
Titanium (Ti) and its alloys as bio-implants have excellent biocompatibilities and osteogenic properties after modification of chemical composition and topography via various methods. The corrosion resistance of these modified materials is of great importance for changing oral system, while few researches have reported this point. Recently, oxidative corrosion induced by cellular metabolites has been well concerned. In this study, we explored the corrosion behaviors of four common materials (commercially pure Ti, cp-Ti; Sandblasting and acid etching-modified Ti, Ti-SLA; nanowires-modified Ti, Ti-NW; and zinc-containing nanowires-modified Ti, Ti-NW-Zn) with excellent biocompatibilities and osteogenic capacities under the macrophages induced-oxidizing microenvironment. The results showed that the materials immersed into a high oxidizing environment were more vulnerable to corrode. Meanwhile, different surfaces also showed various corrosion susceptibilities under oxidizing condition. Samples embed with zinc element exhibited more excellent corrosion resistance compared with other three surfaces exposure to excessive H2O2. Besides, we found that zinc-decorated Ti surfaces inhibited the adhesion and proliferation of macrophages on its surface and induced the M2 states of macrophages to better healing and tissue reconstruction. Most importantly, zinc-decorated Ti surfaces markedly increased the expressions of antioxidant enzyme relative genes in macrophages. It improved the oxidation microenvironment around the materials and further protected their properties. In summary, our results demonstrated that Ti-NW-Zn surfaces not only provided excellent corrosion resistance properties, but also inhibited the adhesion of macrophages. These aspects were necessary for maintaining osseointegration capacity and enhancing the corrosion resistance of Ti in numerous medical applications, particularly in dentistry.
Collapse
|
10
|
Chana M, Lewis JB, Davis R, Elam Y, Hobbs D, Lockwood PE, Wataha JC, Messer RL. Biological effects of Ni(II) on monocytes and macrophages in normal and hyperglycemic environments. J Biomed Mater Res A 2018; 106:2433-2439. [DOI: 10.1002/jbm.a.36437] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Revised: 03/15/2018] [Accepted: 04/05/2018] [Indexed: 12/14/2022]
Affiliation(s)
- Monica Chana
- Department of Oral Health and Diagnostic Sciences, Department of General Dentistry, Dental College of Georgia; Augusta University; Augusta Georgia
| | - Jill B. Lewis
- College of Dental Medicine and Graduate College of Biomedical Sciences; Western University of Health Sciences; Pomona California
| | - Ryan Davis
- Dental College of Georgia; Augusta University; Augusta Georgia
| | - Yolanda Elam
- College of Nursing; Augusta University; Augusta Georgia United States
| | - David Hobbs
- Savannah River National Laboratory; Aiken South Carolina
| | | | - John C. Wataha
- Department of Restorative Dentistry, School of Dentistry; University of Washington; Seattle Washington
| | - Regina L. Messer
- Department of Oral Biology, Dental College of Georgia; Augusta University; Augusta Georgia
| |
Collapse
|
11
|
Mystkowska J, Niemirowicz-Laskowska K, Łysik D, Tokajuk G, Dąbrowski JR, Bucki R. The Role of Oral Cavity Biofilm on Metallic Biomaterial Surface Destruction-Corrosion and Friction Aspects. Int J Mol Sci 2018; 19:E743. [PMID: 29509686 PMCID: PMC5877604 DOI: 10.3390/ijms19030743] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Revised: 02/23/2018] [Accepted: 03/03/2018] [Indexed: 12/14/2022] Open
Abstract
Metallic biomaterials in the oral cavity are exposed to many factors such as saliva, bacterial microflora, food, temperature fluctuations, and mechanical forces. Extreme conditions present in the oral cavity affect biomaterial exploitation and significantly reduce its biofunctionality, limiting the time of exploitation stability. We mainly refer to friction, corrosion, and biocorrosion processes. Saliva plays an important role and is responsible for lubrication and biofilm formation as a transporter of nutrients for microorganisms. The presence of metallic elements in the oral cavity may lead to the formation of electro-galvanic cells and, as a result, may induce corrosion. Transitional microorganisms such as sulfate-reducing bacteria may also be present among the metabolic microflora in the oral cavity, which can induce biological corrosion. Microorganisms that form a biofilm locally change the conditions on the surface of biomaterials and contribute to the intensification of the biocorrosion processes. These processes may enhance allergy to metals, inflammation, or cancer development. On the other hand, the presence of saliva and biofilm may significantly reduce friction and wear on enamel as well as on biomaterials. This work summarizes data on the influence of saliva and oral biofilms on the destruction of metallic biomaterials.
Collapse
Affiliation(s)
- Joanna Mystkowska
- Department of Materials Engineering and Production, Faculty of Mechanical Engineering, Bialystok University of Technology, Wiejska 45C, 15-351 Bialystok, Poland.
| | - Katarzyna Niemirowicz-Laskowska
- Department of Microbiological and Nanobiomedical Engineering, Medical University of Bialystok, Mickiewicza 2C, 15-222 Bialystok, Poland.
| | - Dawid Łysik
- Department of Materials Engineering and Production, Faculty of Mechanical Engineering, Bialystok University of Technology, Wiejska 45C, 15-351 Bialystok, Poland.
| | - Grażyna Tokajuk
- Department of Integrated Dentistry, Medical University of Bialystok, M. Sklodowskiej-Curie 24a, 15-276 Bialystok, Poland.
| | - Jan R Dąbrowski
- Department of Materials Engineering and Production, Faculty of Mechanical Engineering, Bialystok University of Technology, Wiejska 45C, 15-351 Bialystok, Poland.
| | - Robert Bucki
- Department of Microbiological and Nanobiomedical Engineering, Medical University of Bialystok, Mickiewicza 2C, 15-222 Bialystok, Poland.
| |
Collapse
|
12
|
Wang L, Hu X, Ma X, Ma Z, Zhang Y, Lu Y, Li X, Lei W, Feng Y. Promotion of osteointegration under diabetic conditions by tantalum coating-based surface modification on 3-dimensional printed porous titanium implants. Colloids Surf B Biointerfaces 2016; 148:440-452. [DOI: 10.1016/j.colsurfb.2016.09.018] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2016] [Revised: 09/12/2016] [Accepted: 09/13/2016] [Indexed: 12/31/2022]
|
13
|
Al-Hashedi AA, Laurenti M, Abdallah MN, Albuquerque RF, Tamimi F. Electrochemical Treatment of Contaminated Titanium Surfaces in Vitro: An Approach for Implant Surface Decontamination. ACS Biomater Sci Eng 2016; 2:1504-1518. [DOI: 10.1021/acsbiomaterials.6b00265] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Affiliation(s)
- Ashwaq Ali Al-Hashedi
- Faculty
of Dentistry, McGill University, 3640 University Street, Montreal, Quebec H3A 0C7, Canada
- Department
of Prosthodontics, Faculty of Dentistry, Sana’a University, Wadi Dhaher Road, Sana’a, Yemen
| | - Marco Laurenti
- Department
of Physical Chemistry, Complutense University of Madrid, Avenida Séneca,
2, 28040 Madrid, Spain
| | - Mohamed-Nur Abdallah
- Faculty
of Dentistry, McGill University, 3640 University Street, Montreal, Quebec H3A 0C7, Canada
| | - Rubens F. Albuquerque
- Faculty
of Dentistry of Ribeirão Preto, University of São Paulo, 253 Avenida Prof. Dr. Zeferino Vaz, 109 Vila Monte Alegre, Ribeirão Preto, São Paulo, Brazil
| | - Faleh Tamimi
- Faculty
of Dentistry, McGill University, 3640 University Street, Montreal, Quebec H3A 0C7, Canada
| |
Collapse
|
14
|
Ogawa ES, Matos AO, Beline T, Marques IS, Sukotjo C, Mathew MT, Rangel EC, Cruz NC, Mesquita MF, Consani RX, Barão VA. Surface-treated commercially pure titanium for biomedical applications: Electrochemical, structural, mechanical and chemical characterizations. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 65:251-61. [DOI: 10.1016/j.msec.2016.04.036] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2015] [Revised: 03/17/2016] [Accepted: 04/11/2016] [Indexed: 01/04/2023]
|
15
|
Faverani LP, Fogaça JF, Machado T, Silva EA, Barão VAR, Assunção WG. Does Surface Topography Improve Electrochemical Behavior of Ti–6Al–4V Alloy in Different Saliva pH Levels? ACTA ACUST UNITED AC 2015. [DOI: 10.1007/s40735-015-0020-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
16
|
Törne K, Larsson M, Norlin A, Weissenrieder J. Degradation of zinc in saline solutions, plasma, and whole blood. J Biomed Mater Res B Appl Biomater 2015; 104:1141-51. [PMID: 26061136 DOI: 10.1002/jbm.b.33458] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2015] [Revised: 04/30/2015] [Accepted: 05/13/2015] [Indexed: 11/08/2022]
Abstract
The initial degradation of zinc has been investigated through exposures to simulated and real body fluids of increasing complexity: phosphate buffered saline (PBS), Ringer's saline solution, human plasma, and whole blood. Real body fluids were used to close the electrolyte gap between simulated and in vivo environment. Polarization of zinc in whole blood show a passive response not present in other electrolytes. The analysis shows a decrease in corrosion rate with time for plasma and whole blood and an increase for PBS and Ringer's. During exposure to plasma and whole blood a bi-layered corrosion product with poor adherence was formed over a uniformly corroding surface. The corrosion products comprise a mixture of inorganic material and biomolecules. Samples degrading in PBS were prone to localized corrosion and formed thick porous corrosion products of primarily zinc phosphates while in Ringer's solution a gel like layer of zinc carbonate was formed over an interface with shallow pits. The use of whole blood or plasma as electrolytes for short term in vitro evaluation of potential biodegradable metals may provide an improved understanding of the behavior in vivo, while Ringer's solution is preferred over PBS for long term degradation studies of zinc. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1141-1151, 2016.
Collapse
Affiliation(s)
- Karin Törne
- Material Physics, KTH Royal Institute of Technology, Electrum 229, 16440, Kista, Sweden.,St Jude Medical Systems AB, Palmbladsgatan, Uppsala, Sweden
| | - Mariann Larsson
- Material Physics, KTH Royal Institute of Technology, Electrum 229, 16440, Kista, Sweden
| | - Anna Norlin
- St Jude Medical Systems AB, Palmbladsgatan, Uppsala, Sweden
| | - Jonas Weissenrieder
- Material Physics, KTH Royal Institute of Technology, Electrum 229, 16440, Kista, Sweden
| |
Collapse
|
17
|
Corrosion kinetics and topography analysis of Ti–6Al–4V alloy subjected to different mouthwash solutions. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2014; 43:1-10. [DOI: 10.1016/j.msec.2014.06.033] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2014] [Revised: 05/30/2014] [Accepted: 06/30/2014] [Indexed: 11/18/2022]
|
18
|
Tamam E, Turkyilmaz I. Effects of pH and elevated glucose levels on the electrochemical behavior of dental implants. J ORAL IMPLANTOL 2014; 40:153-9. [PMID: 24779948 DOI: 10.1563/aaid-joi-d-11-00083] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Implant failure is more likely to occur in persons with medically compromising systemic conditions, such as diabetes related to high blood glucose levels and inflammatory diseases related to pH levels lower than those in healthy people. The aim of this study was to investigate the effects of lower pH level and simulated- hyperglycemia on implant corrosion as these effects are critical to biocompatibility and osseointegration. The electrochemical corrosion properties of titanium implants were studied in four different solutions: Ringer's physiological solution at pH = 7.0 and pH = 5.5 and Ringer's physiological solution containing 15 mM dextrose at pH = 7 and pH = 5.5. Corrosion behaviors of dental implants were determined by cyclic polarization test and electrochemical impedance spectroscopy. Surface alterations were studied using a scanning electron microscope. All test electrolytes led to apparent differences in corrosion behavior of the implants. The implants under conditions of test exhibited statistically significant increases in I(corr) from 0.2372 to 1.007 μAcm(-2), corrosion rates from 1.904 to 8.085 mpy, and a decrease in polarization resistances from 304 to 74 Ω. Implants in dextrose-containing solutions were more prone to corrosion than those in Ringer's solutions alone. Increasing the acidity also yielded greater corrosion rates for the dextrose-containing solutions and the solutions without dextrose.
Collapse
Affiliation(s)
- Evsen Tamam
- 1 Department of Prosthodontics, Dental School, Gazi University, Ankara, Turkey
| | | |
Collapse
|
19
|
Influence of an Antidiabetic Drug on Biomechanical and Histological Parameters Around Implants in Type 2 Diabetic Rats. IMPLANT DENT 2014; 23:264-9. [DOI: 10.1097/id.0000000000000021] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
20
|
Faverani LP, Assunção WG, de Carvalho PSP, Yuan JCC, Sukotjo C, Mathew MT, Barao VA. Effects of dextrose and lipopolysaccharide on the corrosion behavior of a Ti-6Al-4V alloy with a smooth surface or treated with double-acid-etching. PLoS One 2014; 9:e93377. [PMID: 24671257 PMCID: PMC3966875 DOI: 10.1371/journal.pone.0093377] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2013] [Accepted: 03/03/2014] [Indexed: 12/28/2022] Open
Abstract
Diabetes and infections are associated with a high risk of implant failure. However, the effects of such conditions on the electrochemical stability of titanium materials remain unclear. This study evaluated the corrosion behavior of a Ti-6Al-4V alloy, with a smooth surface or conditioned by double-acid-etching, in simulated body fluid with different concentrations of dextrose and lipopolysaccharide. For the electrochemical assay, the open-circuit-potential, electrochemical impedance spectroscopy, and potentiodynamic test were used. The disc surfaces were characterized by scanning electron microscopy and atomic force microscopy. Their surface roughness and Vickers microhardness were also tested. The quantitative data were analyzed by Pearson's correlation and independent t-tests (α = 0.05). In the corrosion parameters, there was a strong lipopolysaccharide correlation with the Ipass (passivation current density), Cdl (double-layer capacitance), and Rp (polarization resistance) values (p<0.05) for the Ti-6Al-4V alloy with surface treatment by double-acid-etching. The combination of dextrose and lipopolysaccharide was correlated with the Icorr (corrosion current density) and Ipass (p<0.05). The acid-treated groups showed a significant increase in Cdl values and reduced Rp values (p<0.05, t-test). According to the topography, there was an increase in surface roughness (R2 = 0.726, p<0.0001 for the smooth surface; R2 = 0.405, p = 0.036 for the double-acid-etching-treated surface). The microhardness of the smooth Ti-6Al-4V alloy decreased (p<0.05) and that of the treated Ti-6Al-4V alloy increased (p<0.0001). Atomic force microscopy showed changes in the microstructure of the Ti-6Al-4V alloy by increasing the surface thickness mainly in the group associated with dextrose and lipopolysaccharide. The combination of dextrose and lipopolysaccharide affected the corrosion behavior of the Ti-6Al-4V alloy surface treated with double-acid-etching. However, no dose-response corrosion behavior could be observed. These results suggest a greater susceptibility to corrosion of titanium implants in diabetic patients with associated infections.
Collapse
Affiliation(s)
- Leonardo P. Faverani
- Department of Dental Materials and Prosthodontics, Aracatuba Dental School, Universidade Estadual Paulista (UNESP), Aracatuba, São Paulo, Brazil
- Department of Surgery and Integrated Clinic, Aracatuba Dental School, Universidade Estadual Paulista (UNESP), Aracatuba, São Paulo, Brazil
| | - Wirley G. Assunção
- Department of Dental Materials and Prosthodontics, Aracatuba Dental School, Universidade Estadual Paulista (UNESP), Aracatuba, São Paulo, Brazil
| | - Paulo Sérgio P. de Carvalho
- Department of Surgery and Integrated Clinic, Aracatuba Dental School, Universidade Estadual Paulista (UNESP), Aracatuba, São Paulo, Brazil
| | - Judy Chia-Chun Yuan
- Department of Restorative Dentistry, University of Illinois at Chicago–College of Dentistry, Chicago, Illinois, United States of America
| | - Cortino Sukotjo
- Department of Restorative Dentistry, University of Illinois at Chicago–College of Dentistry, Chicago, Illinois, United States of America
| | - Mathew T. Mathew
- Department of Restorative Dentistry, University of Illinois at Chicago–College of Dentistry, Chicago, Illinois, United States of America
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, United States of America
| | - Valentim A. Barao
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil
- * E-mail:
| |
Collapse
|
21
|
Grippo JO, Oh DS. A classification of the mechanisms producing pathological tissue changes. J Med Eng Technol 2013; 37:259-63. [PMID: 23701371 DOI: 10.3109/03091902.2013.789565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
The objectives are to present a classification of mechanisms which can produce pathological changes in body tissues and fluids, as well as to clarify and define the term biocorrosion, which has had a singular use in engineering. Considering the emerging field of biomedical engineering, it is essential to use precise definitions in the lexicons of engineering, bioengineering and related sciences such as medicine, dentistry and veterinary medicine. The mechanisms of stress, friction and biocorrosion and their pathological effects on tissues are described. Biocorrosion refers to the chemical, biochemical and electrochemical changes by degradation or induced growth of living body tissues and fluids. Various agents which can affect living tissues causing biocorrosion are enumerated which support the necessity and justify the use of this encompassing and more precise definition of biocorrosion. A distinction is made between the mechanisms of corrosion and biocorrosion.
Collapse
Affiliation(s)
- John O Grippo
- Biomedical Engineering, Western New England University, Springfield, 01119, USA.
| | | |
Collapse
|
22
|
Delgado-Ruiz RA, Calvo-Guirado JL, Abboud M, Ramirez-Fernandez MP, Mate-Sanchez JE, Negri B, Rothamel D. Histologic and Histomorphometric Behavior of Microgrooved Zirconia Dental Implants with Immediate Loading. Clin Implant Dent Relat Res 2013; 16:856-72. [DOI: 10.1111/cid.12069] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- Rafael Arcesio Delgado-Ruiz
- Department of Prosthodontics and Digital Technology; School of Dental Medicine; Stony Brook University; Stony Brook NY USA
| | | | - Marcus Abboud
- Department of Prosthodontics and Digital Technology; School of Dental Medicine; Stony Brook University; Stony Brook NY USA
| | | | | | - Bruno Negri
- Faculty of Medicine and Dentistry; Murcia University; Murcia Spain
| | - Daniel Rothamel
- Department of Oral and Maxillofacial Plastic Surgery; University of Cologne; Cologne Germany
| |
Collapse
|
23
|
Degradative Effects of the Biological Environment on Metals and Ceramics. Biomater Sci 2013. [DOI: 10.1016/b978-0-08-087780-8.00062-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
24
|
What is the role of lipopolysaccharide on the tribocorrosive behavior of titanium? J Mech Behav Biomed Mater 2012; 8:71-85. [DOI: 10.1016/j.jmbbm.2011.11.004] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2011] [Accepted: 11/11/2011] [Indexed: 11/22/2022]
|
25
|
Barão VAR, Mathew MT, Assunção WG, Yuan JCC, Wimmer MA, Sukotjo C. Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study. Clin Oral Implants Res 2011; 23:1055-62. [DOI: 10.1111/j.1600-0501.2011.02265.x] [Citation(s) in RCA: 93] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/23/2011] [Indexed: 10/17/2022]
Affiliation(s)
- Valentim A. R. Barão
- Department of Dental Materials and Prosthodontics; Aracatuba Dental School; Univ Estadual Paulista (UNESP); Aracatuba; SP; Brazil
| | - Mathew T. Mathew
- Department of Orthopedic Surgery; Rush University Medical Center; Chicago; IL; USA
| | - Wirley Gonçalves Assunção
- Department of Dental Materials and Prosthodontics; Aracatuba Dental School; Univ Estadual Paulista (UNESP); Aracatuba; SP; Brazil
| | - Judy Chia-Chun Yuan
- Department of Restorative Dentistry; College of Dentistry; University of Illinois at Chicago; Chicago; IL; USA
| | - Markus A. Wimmer
- Department of Orthopedic Surgery; Rush University Medical Center; Chicago; IL; USA
| | - Cortino Sukotjo
- Department of Restorative Dentistry; College of Dentistry; University of Illinois at Chicago; Chicago; IL; USA
| |
Collapse
|
26
|
In vitro corrosion study of different TiO2 nanotube layers on titanium in solution with serum proteins. Colloids Surf B Biointerfaces 2011; 84:400-5. [DOI: 10.1016/j.colsurfb.2011.01.033] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2010] [Revised: 01/18/2011] [Accepted: 01/22/2011] [Indexed: 11/24/2022]
|
27
|
Barão V, Mathew M, Assunção W, Yuan J, Wimmer M, Sukotjo C. The Role of Lipopolysaccharide on the Electrochemical Behavior of Titanium. J Dent Res 2011; 90:613-8. [DOI: 10.1177/0022034510396880] [Citation(s) in RCA: 66] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Affiliation(s)
- V.A. Barão
- Department of Dental Materials and Prosthodontics, Univ Estadual Paulista (UNESP), Araçatuba Dental School, Jose Bonifacio, 1193, Araçatuba, São Paulo, 16015-050, Brazil
- Department of Restorative Dentistry, University of Illinois at Chicago – College of Dentistry, 801 S. Paulina, Room 365B, Chicago, IL 60612-7211, USA
| | - M.T. Mathew
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 West Harrison, Chicago, IL 60612-7211, USA
| | - W.G. Assunção
- Department of Dental Materials and Prosthodontics, Univ Estadual Paulista (UNESP), Araçatuba Dental School, Jose Bonifacio, 1193, Araçatuba, São Paulo, 16015-050, Brazil
| | - J.C. Yuan
- Department of Restorative Dentistry, University of Illinois at Chicago – College of Dentistry, 801 S. Paulina, Room 365B, Chicago, IL 60612-7211, USA
| | - M.A. Wimmer
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 West Harrison, Chicago, IL 60612-7211, USA
| | - C. Sukotjo
- Department of Restorative Dentistry, University of Illinois at Chicago – College of Dentistry, 801 S. Paulina, Room 365B, Chicago, IL 60612-7211, USA
| |
Collapse
|
28
|
Stanford CM. Surface modification of biomedical and dental implants and the processes of inflammation, wound healing and bone formation. Int J Mol Sci 2010; 11:354-69. [PMID: 20162020 PMCID: PMC2821008 DOI: 10.3390/ijms11010354] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2009] [Revised: 01/18/2010] [Accepted: 01/20/2010] [Indexed: 11/17/2022] Open
Abstract
Bone adaptation or integration of an implant is characterized by a series of biological reactions that start with bone turnover at the interface (a process of localized necrosis), followed by rapid repair. The wound healing response is guided by a complex activation of macrophages leading to tissue turnover and new osteoblast differentiation on the implant surface. The complex role of implant surface topography and impact on healing response plays a role in biological criteria that can guide the design and development of future tissue-implant surface interfaces.
Collapse
Affiliation(s)
- Clark M Stanford
- Dows Institute for Dental Research, University of Iowa, 52242, USA.
| |
Collapse
|
29
|
Messer RLW, Seta F, Mickalonis J, Brown Y, Lewis JB, Wataha JC. Corrosion of phosphate-enriched titanium oxide surface dental implants (TiUnite) under in vitro inflammatory and hyperglycemic conditions. J Biomed Mater Res B Appl Biomater 2009; 92:525-34. [PMID: 20024965 DOI: 10.1002/jbm.b.31548] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Endosseous dental implants use is increasing in patients with systemic conditions that compromise wound healing. Manufacturers recently have redesigned implants to ensure more reliable and faster osseointegration. One design strategy has been to create a porous phosphate-enriched titanium oxide (TiUnite) surface to increase surface area and enhance interactions with bone. In the current study, the corrosion properties of TiUnite implants were studied in cultures of monocytic cells and solutions simulating inflammatory and hyperglycemic conditions. Furthermore, to investigate whether placement into bone causes enough mechanical damage to alter implant corrosion properties, the enhanced surface implants as well as machined titanium implants were placed into human cadaver mandibular bone, the bone removed, and the corrosion properties measured. Implant corrosion behavior was characterized by open circuit potentials, linear polarization resistance, and electrical impedance spectroscopy. In selected samples, THP1 cells were activated with lipopolysaccharide prior to implant exposure to simulate an inflammatory environment. No significant differences in corrosion potentials were measured between the TiUnite implants and the machined titanium implants in previous studies. TiUnite implants exhibited lower corrosion rates in all simulated conditions than observed in PBS, and EIS measurements revealed two time constants which shifted with protein-containing electrolytes. In addition, the TiUnite implants displayed a significantly lower corrosion rate than the machined titanium implants after placement into bone. The current study suggests that the corrosion risk of the enhanced oxide implant is lower than its machined surface titanium implant counterpart under simulated conditions of inflammation, elevated dextrose concentrations, and after implantation into bone.
Collapse
Affiliation(s)
- Regina L W Messer
- Department of Oral Biology, Medical College of Georgia, Augusta, Georgia, USA
| | | | | | | | | | | |
Collapse
|
30
|
Yu WQ, Qiu J, Xu L, Zhang FQ. Corrosion behaviors of TiO
2
nanotube layers on titanium in Hank's solution. Biomed Mater 2009; 4:065012. [DOI: 10.1088/1748-6041/4/6/065012] [Citation(s) in RCA: 76] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
31
|
Javed F, Romanos GE. Impact of Diabetes Mellitus and Glycemic Control on the Osseointegration of Dental Implants: A Systematic Literature Review. J Periodontol 2009; 80:1719-30. [DOI: 10.1902/jop.2009.090283] [Citation(s) in RCA: 215] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|