1
|
Nishi K, Haji T, Matsumoto T, Hayakawa C, Maeda K, Okano S, Yokoo T, Iwai S. Timing urinary tract reconstruction in rats to avoid hydronephrosis and fibrosis in the transplanted fetal metanephros as assessed using imaging. PLoS One 2021; 16:e0231233. [PMID: 33449930 PMCID: PMC7810319 DOI: 10.1371/journal.pone.0231233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Accepted: 12/29/2020] [Indexed: 11/18/2022] Open
Abstract
Chronic kidney disease leads to high morbidity rates among humans. Kidney transplantation is often necessary for severe symptoms; however, options for new curative treatments are desired because of donor shortage. For example, it has been established that the kidneys can efficiently generate urine after transplantation of the metanephros, ureter, and bladder as a group. After transplantation, the urine can indirectly flow into the recipient's bladder using a stepwise peristaltic ureter system method where the anastomosis is created via the recipient's ureter for urinary tract reconstruction. However, the growth of the regenerated metanephros varies significantly, whereas the time window for successful completion of the stepwise peristaltic ureter system that does not cause hydronephrosis of the metanephros with bladder (ureter) is quite narrow. Therefore, this study was conducted to periodically and noninvasively evaluate the growth of the transplanted metanephros, ureter, and bladder in rats through computed tomography and ultrasonography. The ultrasonographic findings highly correlated to the computed tomography findings and clearly showed the metanephros and bladder. We found that the degree of growth of the metanephros and the bladder after transplantation differed in each case. Most of the rats were ready for urinary tract reconstruction within 21 days after transplantation. Optimizing the urinary tract reconstruction using ultrasonography allowed for interventions to reduce long-term tubular dilation of the metanephros due to inhibited overdilation of the fetal bladder, thereby decreasing the fibrosis caused possibly by transforming growth factor-β1. These results may be significantly related to the long-term maturation of the fetal metanephros and can provide new insights into the physiology of transplant regeneration of the metanephros in higher animals. Thus, this study contributes to the evidence base for the possibility of kidney regeneration in human clinical trials.
Collapse
Affiliation(s)
- Kotaro Nishi
- Laboratory of Small Animal Surgery 2, School of Veterinary Medicine, Kitasato University, Towada, Aomori, Japan
| | - Takafumi Haji
- Laboratory of Small Animal Surgery 2, School of Veterinary Medicine, Kitasato University, Towada, Aomori, Japan
| | - Takuya Matsumoto
- Laboratory of Small Animal Surgery 2, School of Veterinary Medicine, Kitasato University, Towada, Aomori, Japan
| | - Chisato Hayakawa
- Laboratory of Small Animal Surgery 2, School of Veterinary Medicine, Kitasato University, Towada, Aomori, Japan
| | - Kenichi Maeda
- Laboratory of Small Animal Surgery 2, School of Veterinary Medicine, Kitasato University, Towada, Aomori, Japan
| | - Shozo Okano
- Laboratory of Small Animal Surgery 2, School of Veterinary Medicine, Kitasato University, Towada, Aomori, Japan
| | - Takashi Yokoo
- Division of Nephrology and Hypertension, Department of Internal Medicine, The Jikei University School of Medicine, Minato-ku, Tokyo, Japan
- Meiji University International Institute for Bio-Resource Research, Kawasaki, Kanagawa, Japan
| | - Satomi Iwai
- Laboratory of Small Animal Surgery 2, School of Veterinary Medicine, Kitasato University, Towada, Aomori, Japan
- Meiji University International Institute for Bio-Resource Research, Kawasaki, Kanagawa, Japan
- * E-mail:
| |
Collapse
|
2
|
Benjamin A, Chen M, Li Q, Chen L, Dong Y, Carrascal CA, Xie H, Samir AE, Anthony BW. Renal Volume Estimation Using Freehand Ultrasound Scans: An Ex Vivo Demonstration. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:1769-1782. [PMID: 32376189 DOI: 10.1016/j.ultrasmedbio.2020.03.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Revised: 02/27/2020] [Accepted: 03/10/2020] [Indexed: 06/11/2023]
Abstract
Renal volume has the potential to serve as a robust biomarker for tracking the onset and progression of renal diseases and also for quantifying renal function. We propose a method to estimate renal volumes using freehand ultrasound scans at the point of care. A conventional ultrasound probe was augmented with an Intel RealSense D435 i camera. Visual inertial simultaneous localization and mapping was used to localize the probe in free space. The acquired 2-D ultrasound images, segmented by trained clinicians, were combined with the estimated poses of the probe to yield accurate volumes. The method was tested on two ex vivo sheep kidneys embedded in gelatin phantoms. Four different scanning protocols were tested: transverse linear, transverse fan, longitudinal linear and longitudinal fan. The estimated renal volumes were compared with those obtained using the water displacement method, the ellipsoidal method and computed tomography imaging. The water displacement method yielded mean volumes of 66.00 and 66.20 mL for kidneys 1 and 2, respectively (ground truth). Freehand ultrasound scans produced mean volumes of 64.08 mL (2.90% error) and 65.25 mL (1.40% error); the ellipsoidal method yielded volumes of 57.49 mL (12.90% error) and 60.15 mL (9.13% error); and computed tomography yielded a volume of 63.00 mL (4.54% error).
Collapse
Affiliation(s)
- Alex Benjamin
- Device Realization and Computational Instrumentation Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Melinda Chen
- Device Realization and Computational Instrumentation Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Qian Li
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Lei Chen
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Yi Dong
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | | | - Hua Xie
- Philips Research North America, Cambridge, Massachusetts, USA
| | - Anthony E Samir
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Brian W Anthony
- Device Realization and Computational Instrumentation Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
| |
Collapse
|
3
|
Chua ME, Kim JK, Gnech M, Ming JM, Amir B, Fernandez N, Lorenzo AJ, Farhat WA, Hebert D, Dos Santos J, Koyle MA. Clinical implication of renal allograft volume to recipient body surface area ratio in pediatric renal transplant. Pediatr Transplant 2018; 22:e13295. [PMID: 30315631 DOI: 10.1111/petr.13295] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2018] [Revised: 08/04/2018] [Accepted: 08/27/2018] [Indexed: 12/18/2022]
Abstract
Our study aims to assess the clinical implication of RAV/rBSA ratio in PRT as a predictor for attained renal function at 1 year post-transplantation and its association with surgical complications. A retrospective cohort was performed for PRT cases from January 2000 to December 2015 in our institution. Extracted clinical information includes the recipient's demographics, donor type, renal allograft characteristics, arterial, venous and ureteral anastomoses, vascular anastomosis time while kidney off ice, overall operative time, and estimated blood loss. The RAV/rBSA was extrapolated and assessed for its association with renal graft function attained in 1 year post-transplantation and surgical complications within 30-day post-transplantation. A total of 324 PRTs cases were analyzed. The cohort consisted of 187 (52.4%) male and 137 (42.3%) female recipients, with 152 (46.9%) living donor and 172 (53.1%) deceased donor renal transplants, and an overall median age of 155.26 months (IQR 76.70-186.98) at time of renal transplantation. The receiver operating characteristic identified that a RAV/rBSA ratio of 135 was the optimal cutoff in determining the renal graft function outcome. Univariate and multivariate analyses revealed the relative OR for RAV/rBSA ≥ 135 ratio in predicting an eGFR ≥ 90 attained within 1 year post-transplant was highest among younger pediatric recipients (<142.5 months) of deceased kidney donors (OR = 11.143, 95% CI = 3.156-39.34). Conversely, Kaplan-Meier analysis revealed that RAV/rBSA ratio ≥ 135 is associated with lower odds of having eGFR <60 (OR = 0.417, 95% CI = 0.203-0.856). The RAV/rBSA ratio was not associated nor predictive of transplant-related surgical complications. Our study determined that the RAV/rBSA ratio is predictive of renal graft function at 1-year PRT, but not associated with any increased surgical complications.
Collapse
Affiliation(s)
- Michael E Chua
- Division of Urology, The Hospital for Sick Children, Toronto, Ontario, Canada.,Institute of Urology, St. Luke's Medical Center, Quezon City, Philippines
| | - Jin Kyu Kim
- Division of Urology, The Hospital for Sick Children, Toronto, Ontario, Canada.,Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Michele Gnech
- Division of Urology, The Hospital for Sick Children, Toronto, Ontario, Canada.,Department of Surgery, University of Padova, Padua, Veneto, Italy
| | - Jessica M Ming
- Division of Urology, The Hospital for Sick Children, Toronto, Ontario, Canada.,Department of Surgery, University of New Mexico, Albuquerque, New Mexico
| | - Bisma Amir
- Division of Urology, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Nicolas Fernandez
- Division of Urology, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Armando J Lorenzo
- Division of Urology, The Hospital for Sick Children, Toronto, Ontario, Canada.,Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Walid A Farhat
- Division of Urology, The Hospital for Sick Children, Toronto, Ontario, Canada.,Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Diane Hebert
- Department of Nephrology, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Joana Dos Santos
- Division of Urology, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Martin A Koyle
- Division of Urology, The Hospital for Sick Children, Toronto, Ontario, Canada.,Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
4
|
Three-dimensional imaging of living transplanted kidney vasculature by 3D color Doppler ultrasonography. ASIAN BIOMED 2018. [DOI: 10.2478/abm-2010-0049] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Abstract
Background: It is of clinical importance to display the vasculature of transplanted kidney in three-dimensional (3D) and in non-invasive way. 3D color Doppler ultrasonographic imaging (3D-CDUI) is a non-invasive technique to display the 3D vasculature of living organs. Objective: Probe into characteristics of 3D vasculature of living transplanted kidney by 3D-CDUI, and evaluate the clinical value of 3D-CDUI on monitoring complications after operation of renal transplant. Methods: Nine patients who received allogeneic transplantation of kidney were monitored with 3D-CDUI. The instruments used included ACUSON Sequoia 512 and TomTec computer station of 3D-CDUI. Using magnetic positioning free-hand scanning, the 3D reconstruction and display of renal tissue structure and blood flow were performed off-line. Results: All patients underwent 3D-CDUI examinations without any side effect or complication. When acute rejection occurred, the 3D distribution change of renal blood flow signal could be observed clearly. During treatment of acute necrosis of renal tubules, changes of renal blood flow signal in 3D color Doppler images could be detected earlier compared with 2D color Doppler images. The position of embolized vassels could be diagnosed accurately by 3D-CDUI. Conclusion: The 3D-CDUI was helpful to improve diagnosis level of ultrasonography by monitoring complications after renal transplantation.
Collapse
|
5
|
Cool DW, Kachura JR. Radiofrequency Ablation of T1a Renal Cell Carcinomas within Renal Transplant Allografts: Oncologic Outcomes and Graft Viability. J Vasc Interv Radiol 2017; 28:1658-1663. [PMID: 28916346 DOI: 10.1016/j.jvir.2017.07.023] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2017] [Revised: 07/17/2017] [Accepted: 07/23/2017] [Indexed: 02/09/2023] Open
Abstract
PURPOSE To evaluate oncologic outcomes and graft viability after percutaneous radiofrequency (RF) ablation of renal cell carcinoma (RCC) developing within renal transplant allografts. MATERIALS AND METHODS A single-institution, retrospective study reviewed all patients treated with RF ablation for RCC between February 2004 and May 2016. Ten patients were identified (age 49.6 y ± 12.6; 9 men, 1 woman) with 12 biopsy-confirmed RCC tumors within the allograft (all T1a, mean diameter 2.0 cm ± 0.7). Mean time from transplant to RCC diagnosis was 13.2 years ± 6.3. RF ablation was performed on an outpatient basis using conscious sedation. Procedural efficacy, complications, oncologic outcomes, and allograft function were evaluated. Statistical analysis with t tests and Pearson correlation compared allograft function before and after RF ablation and impact of proportional ablation size to allograft volume on function after ablation. RESULTS Technical success rate and primary technique efficacy were 100% (12/12). No local or distant RCC progression was seen at mean follow-up of 54.3 months ± 38.7 (range, 9-136 months). Graft failure requiring hemodialysis or repeat transplantation occurred in 3 patients (26, 354, and 750 d after RF ablation), all of whom had glomerular filtration rate (GFR) < 30 mL/min/1.73 m2 before ablation. For all patients, mean GFR 6 months after RF ablation (35.8 mL/min/1.73 m2 ± 17.7) was not significantly different (P = .8) from preprocedure GFR (36.2 mL/min/1.73 m2 ± 14.3). Proportional volume of allograft that was ablated did not correlate with immediate or long-term GFR changes. One patient died of unrelated comorbidities 52 months after ablation. No major complications occurred. CONCLUSIONS RF ablation of renal allograft RCC provided effective oncologic control without adverse impact on graft viability.
Collapse
Affiliation(s)
- Derek W Cool
- Division of Vascular and Interventional Radiology, Department of Medical Imaging, University of Toronto, University Health Network, 200 Elizabeth St., Toronto, M5G 2C4, Canada.
| | - John R Kachura
- Division of Vascular and Interventional Radiology, Department of Medical Imaging, University of Toronto, University Health Network, 200 Elizabeth St., Toronto, M5G 2C4, Canada
| |
Collapse
|
6
|
Decrease in 1-year Kidney Graft Size Predicts Inferior Outcomes After Deceased Donor Kidney Transplantation. Transplantation 2017; 100:1759-66. [PMID: 26502370 DOI: 10.1097/tp.0000000000000977] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Longest bipolar length of the kidney graft is routinely measured for ultrasonographic assessment of graft size (GS), although the value of the graft length remains unclear. METHODS In a single-center, observational study involving 319 deceased-donor kidney transplant recipients, we assessed variations in absolute and adjusted GS (corrected for body surface area) between 1 and 12 months after transplantation ([INCREMENT]GS1m→12m). We tested whether variations in GS during the first year were predictive of the composite outcome of a reduction of 50% or more in the estimated glomerular filtration rate or end-stage graft failure. RESULTS At 1 year after transplantation, 121 patients (38%) had a decrease in GS ([INCREMENT]GS1m→12m <0), and 198 patients (62%) had an increase in GS ([INCREMENT]GS1m→12m ≥0). After a median follow-up of 53 months, 41 patients with a decrease in GS reached the composite outcome as compared with 12 patients with an increase in GS (34% and 6%, respectively; P < 0.001). Areas under the receiver operating characteristics curves of absolute and adjusted [INCREMENT]GS1m→12m for composite outcome were 0.81 (95% confidence interval [95% CI], 0.74-0.88) and 0.78 (95% CI, 0.70-0.86), respectively. In multivariate analysis, the risk of the composite outcome was significantly higher among patients with a decrease in GS during the first year after transplantation (hazard ratio, 4.55; 95% CI, 2.35-8.81; P < 0.001). CONCLUSIONS A decrease in kidney GS during the first year after transplantation, as compared with an increase in GS, is a powerful predictor of subsequent graft dysfunction or end-stage graft failure.
Collapse
|
7
|
van der Sande NG, Blankestijn PJ, Leiner T, van der Graaf Y, de Borst GJ, Cramer MJ, Visseren FL. High ratios of kidney function to kidney size are related to mortality and kidney function decline in high-risk patients. Eur J Prev Cardiol 2017; 24:926-933. [PMID: 28121180 DOI: 10.1177/2047487317690950] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Background The ratio of estimated glomerular filtration rate (eGFR) to kidney size reflects the kidney's capacity for filtration per kidney volume or kidney length. High ratios of eGFR to kidney size, which might indicate glomerular hyperfiltration, could be related to kidney function decline, cardiovascular disease and mortality. Methods In 6926 patients with clinically manifest vascular disease, we evaluated the relationship between eGFR/kidney size and the risk of cardiovascular events and all-cause mortality using Cox regression. Quartiles were made for eGFR/kidney size, using the second quartile as the reference category. In 1516 patients with second measurements of eGFR, linear regression was used to evaluate the relationship between eGFR/kidney size and annual kidney function decline. Results The relationship between eGFR/kidney size and all-cause mortality followed a reversed J-shaped curve with increased risk for the lowest (hazard ratio (HR) 1.17; 95% confidence interval (CI) 1.01-1.36) and highest quartile (HR 1.04; 95% CI 0.87-1.25) of eGFR/volume, and for the lowest (HR 1.37;95%CI 1.19-1.59) and highest quartile (HR 1.28; 95% CI 1.06-1.54) of eGFR/length. The risk for cardiovascular events was increased for the lowest quartile of eGFR/length (HR 1.55; 95% CI 1.33-1.82). An increase in eGFR/volume and eGFR/length, was related to a greater kidney function decline, β -0.34 (95% CI -0.42 to -0.26) and β -0.55 (95% CI -0.63 to -0.48) ml/min/1.73 m2 per year respectively. Conclusions High eGFR/volume and eGFR/length, which might indicate glomerular hyperfiltration, are related to kidney function decline. High eGFR/length confers an increased risk for all-cause mortality in patients with clinically manifest vascular disease.
Collapse
Affiliation(s)
- Nicolette Gc van der Sande
- 1 Department of Vascular Medicine, University Medical Center Utrecht, Utrecht, the Netherlands.,2 Department of Nephrology and Hypertension, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Peter J Blankestijn
- 2 Department of Nephrology and Hypertension, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Tim Leiner
- 3 Department of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Yolanda van der Graaf
- 4 Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Gert Jan de Borst
- 5 Department of Vascular Surgery, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Maarten Jm Cramer
- 6 Department of Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Frank Lj Visseren
- 1 Department of Vascular Medicine, University Medical Center Utrecht, Utrecht, the Netherlands
| | | |
Collapse
|
8
|
Ideguchi M, Kajiwara K, Yoshikawa K, Sadahiro H, Nomura S, Fujii M, Suzuki M. Characteristics of intraoperative abnormal hemodynamics during resection of an intra-fourth ventricular tumor located on the dorsal medulla oblongata. Neurol Med Chir (Tokyo) 2013; 53:655-62. [PMID: 24077276 PMCID: PMC4508747 DOI: 10.2176/nmc.oa2012-0401] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Abnormal hemodynamics during extirpation of a para-medulla oblongata (MO) tumor is common and may be associated with direct vagal stimulation of the medullary circuit. However, resection of tumors on the dorsal MO may also induce hemodynamic instability without direct vagal stimulus. The objective of this study was to examine the characteristics of hemodynamic instability unrelated to vagal stimulus during dissection of an intra-fourth ventricular tumor with attachment to the dorsal MO. A retrospective analysis was performed in 13 patients. Abnormal hemodynamics were defined as a > 20% change from the means of the intraoperative mean arterial pressure (MAP) and heart rate (HR). Relationships of intraoperative hemodynamics were evaluated with various parameters, including the volume of the MO. Six patients (46.2%) had intraoperative hypertension during separation of the tumor bulk from the dorsal MO. The maximum MAP and HR in these patients were significantly greater than those in patients with normal hemodynamics (116.0 ± 18.0 mmHg versus 85.6 ± 6.5 mmHg; 124.3 ± 22.8 bpm versus 90.5 ± 14.7 bpm). All six cases with abnormal hemodynamics showed hemodynamic fluctuation during separation of the tumor bulk from the dorsal MO. The preoperative volume of the MO in these patients was 1.11 cc less than that in patients with normal hemodynamics, but the volume after tumor resection was similar in the two groups (5.23 cc and 5.12 cc). This suggests that the MO was compressed by the conglutinate tumor bulk, with resultant fluctuation of hemodynamics. Recognition of and preparation for this phenomenon are important for surgery on a tumor located on the dorsal MO.
Collapse
Affiliation(s)
- Makoto Ideguchi
- Department of Neurosurgery, Yamaguchi University Graduate School of Medicine
| | | | | | | | | | | | | |
Collapse
|
9
|
Fonseca AL, Schuster KM, Maung AA, Kaplan LJ, Davis KA. Routine Nasogastric Decompression in Small Bowel Obstruction: Is it Really Necessary? Am Surg 2013. [DOI: 10.1177/000313481307900433] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
Bowel rest, nasogastric (NG) decompression, and intravenous hydration are used to treat small bowel obstruction (SBO) conservatively; however, there are no data to support nasogastric tube (NGT) use in patients without active emesis. We aim to evaluate the use of nasogastric decompression in SBO and the safety of managing patients with SBO without the use of a NGT. A retrospective chart review was conducted of adult patients admitted to Yale New Haven Hospital over five years with the diagnosis of SBO. We compared patients who received NG decompression with those who did not. Outcome variables assessed were days to resolution, associated complications, hospital length of stay, and disposition. Of 290 patients who fit the criteria, 190 patients (65.52%) were managed conservatively. Fifty-five patients (18.97%) did not receive NGTs. Sixty-eight patients (23.45%) did not present with emesis; however, nearly 75 per cent of these patients received NGTs. Development of pneumonia and respiratory failure was significantly associated with NGT placement. Time to resolution and hospital length of stay were significantly higher in patients with NGTs. Patients with NG decompression had a significantly increased risk of pneumonia and respiratory failure as well as increased time to resolution and hospital length of stay.
Collapse
Affiliation(s)
| | - Kevin M. Schuster
- From the Department of Surgery, Yale School of Medicine, New Haven, Connecticut
| | - Adrian A. Maung
- From the Department of Surgery, Yale School of Medicine, New Haven, Connecticut
| | - Lewis J. Kaplan
- From the Department of Surgery, Yale School of Medicine, New Haven, Connecticut
| | - Kimberly A. Davis
- From the Department of Surgery, Yale School of Medicine, New Haven, Connecticut
| |
Collapse
|
10
|
Tyson R, Logsdon SA, Werre SR, Daniel GB. Estimation of feline renal volume using computed tomography and ultrasound. Vet Radiol Ultrasound 2012; 54:127-32. [PMID: 23278991 DOI: 10.1111/vru.12007] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2012] [Accepted: 11/14/2012] [Indexed: 11/27/2022] Open
Abstract
Renal volume estimation is an important parameter for clinical evaluation of kidneys and research applications. A time efficient, repeatable, and accurate method for volume estimation is required. The purpose of this study was to describe the accuracy of ultrasound and computed tomography (CT) for estimating feline renal volume. Standardized ultrasound and CT scans were acquired for kidneys of 12 cadaver cats, in situ. Ultrasound and CT multiplanar reconstructions were used to record renal length measurements that were then used to calculate volume using the prolate ellipsoid formula for volume estimation. In addition, CT studies were reconstructed at 1 mm, 5 mm, and 1 cm, and transferred to a workstation where the renal volume was calculated using the voxel count method (hand drawn regions of interest). The reference standard kidney volume was then determined ex vivo using water displacement with the Archimedes' principle. Ultrasound measurement of renal length accounted for approximately 87% of the variability in renal volume for the study population. The prolate ellipsoid formula exhibited proportional bias and underestimated renal volume by a median of 18.9%. Computed tomography volume estimates using the voxel count method with hand-traced regions of interest provided the most accurate results, with increasing accuracy for smaller voxel sizes in grossly normal kidneys (-10.1 to 0.6%). Findings from this study supported the use of CT and the voxel count method for estimating feline renal volume in future clinical and research studies.
Collapse
Affiliation(s)
- Reid Tyson
- Department of Small Animal Clinical Sciences, Virginia-Maryland Regional College of Veterinary Medicine, Virginia Tech, Blacksburg, VA 24061, USA.
| | | | | | | |
Collapse
|
11
|
Maeda Y, Shirao S, Yoneda H, Ishihara H, Shinoyama M, Oka F, Sadahiro H, Ueda K, Sano Y, Kudomi S, Hayashi Y, Shigeeda T, Nakano K, Koizumi H, Nomura S, Fujii M, Nomura S, Suzuki M. Comparison of lumbar drainage and external ventricular drainage for clearance of subarachnoid clots after Guglielmi detachable coil embolization for aneurysmal subarachnoid hemorrhage. Clin Neurol Neurosurg 2012; 115:965-70. [PMID: 23107165 DOI: 10.1016/j.clineuro.2012.10.001] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2012] [Revised: 09/02/2012] [Accepted: 10/01/2012] [Indexed: 11/28/2022]
Abstract
OBJECTIVE Subarachnoid clots play an important role in development of delayed vasospasm after subarachnoid hemorrhage (SAH). The purpose of this study was to compare clearance of subarachnoid clots using external ventricular drainage (EVD) or lumbar drainage (LD) after Guglielmi detachable coil (GDC) embolization for aneurysmal SAH. METHODS The subjects were 51 treated with GDC coil embolization for aneurysmal Fisher group 3 SAH within 72 h of ictus. Software-based volumetric quantification of the subarachnoid clots was performed on CT scans and the hemoglobin (Hb) level was measured in CSF drained from each catheter. RESULTS Clearance of subarachnoid clots was more rapid in patients treated with LD (n=34) compared to those treated with EVD (n=17). The Hb level in CSF was significantly higher in the LD group on Days 4-5 after onset of SAH (P<0.05), but was higher in the EVD group on Days 8-9. The incidence of symptomatic vasospasm did not differ between the two groups. The rate of occurrence of a new low density area on CT scans was higher in patients treated with EVD, but not significantly higher than the rate in the LD group. CONCLUSION GDC embolization followed by lumbar drainage accelerates the reduction of subarachnoid clots, but EVD may contribute to stasis of hemorrhage within subarachnoid spaces.
Collapse
Affiliation(s)
- Yoshihiko Maeda
- Department of Neurosurgery and Clinical Neuroscience, Yamaguchi University School of Medicine, Ube, Japan
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Gupta S, Singh AH, Shabbir A, Hahn PF, Harris G, Sahani D. Assessing renal parenchymal volume on unenhanced CT as a marker for predicting renal function in patients with chronic kidney disease. Acad Radiol 2012; 19:654-60. [PMID: 22578224 DOI: 10.1016/j.acra.2012.02.006] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2011] [Revised: 02/10/2012] [Accepted: 02/13/2012] [Indexed: 11/18/2022]
Abstract
OBJECTIVES To estimate renal volume in chronic kidney disease (CKD) patients using a semiautomated software and compare them with split renal function estimates from radionuclide renogram (RR). We proposed that renal volume from unenhanced computed tomography (CT) scans may serve as surrogate marker for assessing renal function in CKD patients. MATERIALS AND METHODS Unenhanced multidetector CT scans of 26 patients with CKD (estimated glomerular filtration rate [eGFR] <60 mL/kg/body surface area [BSA]) and 10 controls (eGFR >60 mL/kg/BSA) were analyzed to calculate renal volumes using a semiautomated software (AMIRAV5.2.0). Volumes obtained were then correlated with corresponding eGFR and split renal function estimates from RR. Volumes were also compared with those obtained on enhanced scans in 10 cases (five disease group, five controls). Bland-Altman analysis was used to assess agreement between methods. RESULTS A moderately positive correlation was found between renal volume obtained on unenhanced CT and eGFR (r = 0.65, P < .0001), whereas a significantly high correlation with split function estimates from RR (r = 0.95, P < .001) was found. Bland-Altman analysis revealed a good agreement between renal volume from CT and renal function from RR (34/36 observations were within 95% CI and there were two outliers). Correlation between volumes obtained from unenhanced and enhanced CT scans was also significant (r = 0.96). CONCLUSION In patients with CKD, renal volume derived from unenhanced CT can possibly serve as a surrogate marker for assessing and monitoring renal function reserves to plan further management.
Collapse
Affiliation(s)
- Supriya Gupta
- Department of Abdominal and Interventional Radiology, Massachusetts General Hospital, 55 Fruit Street, White 270, Boston, MA 02114, USA.
| | | | | | | | | | | |
Collapse
|
13
|
Shirao S, Yoneda H, Ishihara H, Harada K, Ueda K, Sano Y, Kudomi S, Hayashi Y, Shigeeda T, Nakano K, Nomura S, Fujii M, Kato S, Suzuki M. Fate of clots in patients with subarachnoid hemorrhage after different surgical treatment modality: a comparison between surgical clipping and Guglielmi detachable coil embolization. Neurosurgery 2012; 68:966-73; discussion 973. [PMID: 21221040 DOI: 10.1227/neu.0b013e318208f1ba] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Subarachnoid clot is important in the development of delayed vasospasm after subarachnoid hemorrhage (SAH). OBJECTIVE To compare the clearance of subarachnoid clot and the incidence of symptomatic vasospasm in surgical clipping and embolization with Guglielmi detachable coils for aneurysmal SAH. METHODS The subjects were 115 patients with Fisher group 3 aneurysmal SAH on computed tomography scan at admission whose aneurysm was treated by surgical clipping (clip group; n = 86) or Guglielmi detachable coil embolization (coil group; n = 29) within 72 hours of ictus. Software-based volumetric quantification of the subarachnoid clot was performed, and the amount of hemoglobin in drained cerebrospinal fluid was measured. RESULTS Clearance of the subarachnoid clot on the computed tomography scan was rapid in the clip group until the day after the operation but slow in the coil group (58.9% removed vs 27.8% removed; P = .008). However, postoperative clearance of the clot occurred more rapidly in the coil group. Reduction of the clot until days 3 through 5 did not differ significantly between the 2 groups (72.9% removed vs 75.2% removed). The amount of hemoglobin in the clip group was > 0.8 g/d until day 3 and then gradually decreased (n = 15), but hemoglobin in the coil group remained at > 0.8 g/d until day 5 (n = 17). The incidence of symptomatic vasospasm did not differ between the groups. CONCLUSION Subarachnoid clot can be removed directly during surgical clipping, which is not possible with endovascular treatment. However, the percentage reduction of the clot on days 3 through 5 did not differ between the 2 groups.
Collapse
Affiliation(s)
- Satoshi Shirao
- Department of Neurosurgery and Clinical Neuroscience, Yamaguchi University School of Medicine, Ube, Japan.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Chang J, Ahn S, Choi S, Lee H, Chang D, Choi H, Lee Y. Evaluation of glomerular filtration rate by use of dynamic computed tomography and Patlak analysis in clinically normal cats. Am J Vet Res 2011; 72:1276-82. [DOI: 10.2460/ajvr.72.9.1276] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
15
|
Hwang HS, Yoon HE, Park JH, Chun HJ, Park CW, Yang CW, Kim YS, Choi BS. Noninvasive and direct measures of kidney size in kidney donors. Am J Kidney Dis 2011; 58:266-71. [PMID: 21601326 DOI: 10.1053/j.ajkd.2011.02.392] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2010] [Accepted: 02/17/2011] [Indexed: 11/11/2022]
Abstract
BACKGROUND Kidney size is important for clinical assessment of kidney disease. This study was performed to determine the usefulness of radiologic methods for predicting direct measurements of kidney size. STUDY DESIGN Diagnostic test study. SETTING & PARTICIPANTS 139 living kidney donors were enrolled. INDEX TEST Body mass index, body surface area, and total-body water were estimated from body height and weight. Kidney lengths were estimated using ultrasound sonography (US) and computed tomography (CT), and kidney volumes were estimated from CT scans using the ellipsoid and voxel-count methods. REFERENCE TEST Kidney length and weight were measured directly after donor nephrectomy. RESULTS Mean measured kidney length and weight were 11.5 ± 0.9 cm and 188.5 ± 33.5 g, respectively. All body indexes correlated with measured size of the left kidney; the highest correlation was between body weight and measured kidney weight (γ = 0.54; P < 0.001). The difference between measured and estimated lengths was greater for US than for CT (-1.1 ± 0.9 cm for US [P < 0.001] vs -0.7 ± 0.7 cm for CT [P < 0.001]). Bland-Altman analysis showed that limits of agreement between CT estimates and measured kidney length (-0.62 to 2.75 cm) were narrower than those between US estimates and measured kidney length (-0.78 to 2.15 cm). Correlation coefficients between radiologic estimates and measured kidney weight were 0.41 and 0.49 for US and CT estimates of kidney length and 0.72 and 0.79 for volume estimates using the ellipsoid and voxel-count methods, respectively (all P < 0.01). LIMITATIONS No direct measurement of kidney volume. CONCLUSIONS CT estimation of kidney length is more accurate than US estimation, and CT estimation of kidney volume using the voxel-count method is most useful to predict kidney weight.
Collapse
Affiliation(s)
- Hyeon Seok Hwang
- Division of Nephrology, Department of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | | | | | | | | | | | | | | |
Collapse
|
16
|
Muto NS, Kamishima T, Harris AA, Kato F, Onodera Y, Terae S, Shirato H. Renal cortical volume measured using automatic contouring software for computed tomography and its relationship with BMI, age and renal function. Eur J Radiol 2011; 78:151-6. [PMID: 19914788 DOI: 10.1016/j.ejrad.2009.10.005] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2009] [Revised: 09/28/2009] [Accepted: 10/01/2009] [Indexed: 10/20/2022]
|
17
|
Rezai P, Tochetto S, Galizia M, Yaghmai V. Perinephric hematoma: semi-automated quantification of volume on MDCT: a feasibility study. ACTA ACUST UNITED AC 2010; 36:222-7. [DOI: 10.1007/s00261-010-9634-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
18
|
Donadio C, Abdelkawy H, Grassi G. Echographic Renal Dimensions Can Predict Glomerular Filtration Rate of Potential Living Kidney Donors. Transplant Proc 2010; 42:1035-9. [DOI: 10.1016/j.transproceed.2010.03.039] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
19
|
Sanusi AA, Arogundade FA, Famurewa OC, Akintomide AO, Soyinka FO, Ojo OE, Akinsola A. Relationship of ultrasonographically determined kidney volume with measured GFR, calculated creatinine clearance and other parameters in chronic kidney disease (CKD). Nephrol Dial Transplant 2009; 24:1690-4. [PMID: 19264744 DOI: 10.1093/ndt/gfp055] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
INTRODUCTION Kidney length has traditionally been used as a predictor of chronic kidney disease (CKD); however, kidney volume (KV) rather than length has been emphasized by researchers as a true predictor of kidney size in states of good health and disease. Since KV can be assumed to be a predictor of kidney mass or remaining surviving nephrons in CKD patients, we theorized that the KV should reflect the functional capacity of the kidneys, i.e. the glomerular filtration rate (GFR). METHODOLOGY Forty CKD patients were recruited and investigated. Measured GFR was determined by calculating the average of endogenous creatinine clearance (mCrCl) and urea clearance (mUrCl) while predicted GFR was determined using Cockcroft and Gault, Hull and Modification of Diet in Renal Disease (MDRD) equations. KV was assessed ultrasonographically using the formulae of Dinkel et al. and Solvig et al. for ellipsoid organ. The relationship between the KV and GFR was assessed using Spearman's correlation coefficient while Bland and Altman tests were used to assess intraobserver variation and agreement between measured and predicted GFR. RESULTS The results showed a weak but positive correlation between KV and various indices of GFR, best with measured CrCl (correlation coefficient ranged between 0.408 and 0.503; P < 0.05), and which was not improved after normalization for body surface area (BSA). We also found a significant correlation between the measured CrCl and various values of estimated CrCl. CONCLUSION Ultrasonographically determined KV was found to correlate with GFR and hence can be used to predict it in established CKD, particularly in resource-poor settings.
Collapse
Affiliation(s)
- Abubakr A Sanusi
- Renal Unit, Department of Medicine, Obafemi Awolowo University/Teaching Hospitals Complex, Ile-Ife, Nigeria.
| | | | | | | | | | | | | |
Collapse
|
20
|
Almajdub M, Magnier L, Juillard L, Janier M. Kidney volume quantification using contrast-enhancedin vivoX-ray micro-CT in mice. CONTRAST MEDIA & MOLECULAR IMAGING 2008; 3:120-6. [DOI: 10.1002/cmmi.238] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
21
|
Cohen EI, Kelly SA, Edye M, Mitty HA, Bromberg JS. MRI estimation of total renal volume demonstrates significant association with healthy donor weight. Eur J Radiol 2008; 71:283-7. [PMID: 18436402 DOI: 10.1016/j.ejrad.2008.03.006] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2007] [Revised: 02/05/2008] [Accepted: 03/03/2008] [Indexed: 10/22/2022]
Abstract
PURPOSE The purpose of this study was to correlate total renal volume (TRV) calculations, obtained through the voxel-count method and ellipsoid formula with various physical characteristics. MATERIALS AND METHODS MRI reports and physical examination from 210 healthy kidney donors (420 kidneys), on whom renal volumes were obtained using the voxel-count method, were retrospectively reviewed. These values along with ones obtained through a more traditional method (ellipsoid formula) were correlated with subject height, body weight, body mass index (BMI), and age. RESULTS TRV correlated strongly with body weight (r=0.7) and to a lesser degree with height, age, or BMI (r=0.5, -0.2, 0.3, respectively). The left kidney volume was greater than the right, on average (p<0.001). The ellipsoid formula method over-estimated renal volume by 17% on average which was significant (p<0.001). CONCLUSIONS Body weight was the physical characteristic which demonstrated the strongest correlation with renal volume in healthy subjects. Given this finding, a formula was derived for estimating the TRV for a given patient based on the his or her weight: TRV = 2.96 x weight (kg) + 113+/-64.
Collapse
Affiliation(s)
- Emil I Cohen
- Mount Sinai Medical Center, Department of Radiology, Box 1234, 1 Gustave L Levy Place, New York, NY 10029, United States.
| | | | | | | | | |
Collapse
|
22
|
Paleologo G, Abdelkawy H, Barsotti M, Basha A, Bernabini G, Bianchi A, Caprio F, Emad A, Grassi G, Nerucci B, Tregnaghi C, Rizzo G, Donadio C. Kidney dimensions at sonography are correlated with glomerular filtration rate in renal transplant recipients and in kidney donors. Transplant Proc 2007; 39:1779-81. [PMID: 17692610 DOI: 10.1016/j.transproceed.2007.05.003] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The gold standard to assess renal function is the measurement of glomerular filtration rate (GFR). For practical reasons, renal function is often evaluated from serum creatinine (S Cr) or cystatin C (S Cys), and GFR is predicted from SCr. Ultrasound scanning of the kidneys is used only to evaluate renal morphology. The aim of this study was to evaluate the relationship between sonographic renal dimensions and GFR in renal transplant recipients and in kidney donors. GFR (urinary clearance of (99m)Tc-DTPA), S Cr, and S Cys were measured in 33 donors (28 females [F], 5 males [M]; SCr, 0.81-1.90 mg/dL) and 30 recipients (8 F, 22 M; SCr, 0.96-2.42 mg/dL). GFR was also predicted using the Cockcroft and Gault (CG) formula and with the simplified Modification of Diet in Renal Disease (MDRD) formula. Length, width, and depth of kidneys and renal sinus were measured using renal sonography. Among sonographic measurements, kidney length showed the best correlation with GFR. A closer correlation with GFR was found in donors (r = 0.639; P < .00007) than in recipients (r = 0.511; P < .005). In either case, the correlation of kidney length with GFR was greater than that of S Cr or S Cys, and similar to that of CG or MDRD GFR. Accuracy of kidney length as an indicator of GFR impairment was not statistically different from laboratory tests. Only in donors did CG show better accuracy. In conclusion, renal dimensions at sonography closely correlated with GFR. Thus, renal sonography can give information also on the function of the renal graft and of the remaining kidney of living donors.
Collapse
Affiliation(s)
- G Paleologo
- Nefrologia con Trapianti, Azienda Ospedaliero-Universitaria, Pisa, Italy
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
|