van Helvert M, Ruisch J, de Bakker JMK, Saris AECM, de Korte CL, Versluis M, Groot Jebbink E, Reijnen MMPJ. High-Frame-Rate Ultrasound Velocimetry in the Healthy Femoral Bifurcation: A Comparative Study Against 4-D Flow Magnetic Resonance Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:1755-1763. [PMID: 39244482 DOI: 10.1016/j.ultrasmedbio.2024.05.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Revised: 05/13/2024] [Accepted: 05/14/2024] [Indexed: 09/09/2024]
Abstract
OBJECTIVE Local flow dynamics impact atherosclerosis yet are difficult to quantify with conventional ultrasound techniques. This study investigates the performance of ultrasound vector flow imaging (US-VFI) with and without ultrasound contrast agents in the healthy femoral bifurcation. METHODS High-frame-rate ultrasound data with incremental acoustic outputs were acquired in the femoral bifurcations of 20 healthy subjects before (50V) and after contrast injection (2V, 5V and 10V). 2-D blood-velocity profiles were obtained through native blood speckle tracking (BST) and contrast tracking (echo particle image velocimetry [echoPIV]). As a reference, 4-D flow magnetic resonance imaging (4-D flow MRI) was acquired. Contrast-to-background ratio and vector correlation were used to assess the quality of the US-VFI acquisitions. Spatiotemporal velocity profiles were extracted, from which peak velocities (PSV) were compared between the modalities. Furthermore, root-mean-square error analysis was performed. RESULTS US-VFI was successful in 99% of the cases and optimal VFI quality was established with the 10V echoPIV and BST settings. A good correspondence between 10V echoPIV and BST was found, with a mean PSV difference of -0.5 cm/s (limits of agreement: -14.1-13.2). Both US-VFI techniques compared well with 4-D flow MRI, with a mean PSV difference of 1.4 cm/s (-18.7-21.6) between 10V echoPIV and MRI, and 0.3 cm/s (-23.8-24.4) between BST and MRI. Similar complex flow patterns among all modalities were observed. CONCLUSION 2-D blood-flow quantification of femoral bifurcation is feasible with echoPIV and BST. Both modalities showed good agreement compared to 4-D flow MRI. For the femoral tract the administration of contrast was not needed to increase the echogenicity of the blood for optimal image quality.
Collapse
Affiliation(s)
- Majorie van Helvert
- Multi-Modality Medical Imaging Group, TechMed Centre, University of Twente, Enschede, The Netherlands; Department of Vascular Surgery, Rijnstate Hospital, Arnhem, The Netherlands; Physics of Fluids Group, TechMed Centre, University of Twente, Enschede, The Netherlands.
| | - Janna Ruisch
- Department of Vascular Surgery, Rijnstate Hospital, Arnhem, The Netherlands; Medical Ultrasound Imaging Centre, Department of Medical Imaging, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Joosje M K de Bakker
- Medical Ultrasound Imaging Centre, Department of Medical Imaging, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Anne E C M Saris
- Medical Ultrasound Imaging Centre, Department of Medical Imaging, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Chris L de Korte
- Physics of Fluids Group, TechMed Centre, University of Twente, Enschede, The Netherlands; Medical Ultrasound Imaging Centre, Department of Medical Imaging, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Michel Versluis
- Physics of Fluids Group, TechMed Centre, University of Twente, Enschede, The Netherlands
| | - Erik Groot Jebbink
- Multi-Modality Medical Imaging Group, TechMed Centre, University of Twente, Enschede, The Netherlands; Department of Vascular Surgery, Rijnstate Hospital, Arnhem, The Netherlands
| | - Michel M P J Reijnen
- Multi-Modality Medical Imaging Group, TechMed Centre, University of Twente, Enschede, The Netherlands; Department of Vascular Surgery, Rijnstate Hospital, Arnhem, The Netherlands
| |
Collapse
|
2
|
Garrigues‐Ramón M, Arca‐Arias A, Carrasco‐Ribelles LA, Barrios C. Haemodynamic effect of a leg compression bandage on the distal posterior tibial artery using 4D flow magnetic resonance imaging: A quantitative study. Int Wound J 2024; 21:e14901. [PMID: 38937919 PMCID: PMC11211091 DOI: 10.1111/iwj.14901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2024] [Revised: 04/21/2024] [Accepted: 04/22/2024] [Indexed: 06/29/2024] Open
Abstract
The uncertainty concerning the physiological effects of compression bandaging on the peripheral blood flow is a challenge for healthcare professionals. The main objective was to determine the haemodynamic impact on the distal posterior tibial artery after the application of a high-compression leg multicomponent bandaging system using 4D flow magnetic resonance imaging. Leg dominance disparities of the posterior tibial artery before and after the application of the compressive bandage were also analysed. Twenty-eight healthy female volunteers were recruited (mean: 25.71, standard deviation: 4.74 years old) through a non-probability convenience sampling. The 4D flow magnetic resonance imaging of the distal tibial posterior artery was performed in all participants, first under standard resting conditions and after the application of a compression bandage in the leg. When the strong compressive bandage was applied, the area of the assessed artery decreased by 14.2%, whilst the average speed increased by 19.6% and the flow rate increased by 184.8%. There were differences between the haemodynamic parameters of both legs according to dominance, being statistically significantly lower in the dominant leg. The application of strong compressive bandaging significantly increases the arterial flow and mean velocity in the distal segment of the posterior tibial artery, in healthy volunteers by 4D flow magnetic resonance imaging. In this study, leg dominance influenced some of the haemodynamic parameters. According to the results, leg compression bandages cannot be contraindicated in vascular ulcers with arterial compromise.
Collapse
Affiliation(s)
- Marta Garrigues‐Ramón
- Fundación Jiménez Díaz School of NursingAutonomous University of MadridMadridSpain
- Health Research Institute‐Fundación Jiménez Díaz University HospitalAutonomous University of Madrid (IIS‐FJD, UAM)MadridSpain
- School of DoctorateValencia Catholic UniversityValenciaSpain
| | | | - Lucía A. Carrasco‐Ribelles
- Fundació Institut Universitari per a la recerca a l'Atenció Primària de Salut Jordi Gol I Gurina (IDIAPJGol)BarcelonaSpain
| | - Carlos Barrios
- Institute for Research on Musculoskeletal DisordersValencia Catholic University Saint Vicent MartyrValenciaSpain
| |
Collapse
|
3
|
Kwak D, Im Y, Nam H, Nam U, Kim S, Kim W, Kim HJ, Park J, Jeon JS. Analyzing the effects of helical flow in blood vessels using acoustofluidic-based dynamic flow generator. Acta Biomater 2024; 177:216-227. [PMID: 38253303 DOI: 10.1016/j.actbio.2024.01.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 12/26/2023] [Accepted: 01/16/2024] [Indexed: 01/24/2024]
Abstract
The effects of helical flow in a blood vessel are investigated in a dynamic flow generator using surface acoustic wave (SAW) in the microfluidic device. The SAW, generated by an interdigital transducer (IDT), induces acoustic streaming, resulting in a stable and consistent helical flow pattern in microscale channels. This approach allows rapid development of helical flow within the channel without directly contacting the medium. The precise design of the window enables the creation of distinct unidirectional vortices, which can be controlled by adjusting the amplitude of the SAW. Within this device, optimal operational parameters of the dynamic flow generator to preserve the integrity of endothelial cells are found, and in such settings, the actin filaments within the cells are aligned to the desired state. Our findings reveal that intracellular Ca2+ concentrations vary in response to flow conditions. Specifically, comparable maximum intensity and graphical patterns were observed between low-flow rate helical flow and high-flow rate Hagen-Poiseuille flow. These suggest that the cells respond to the helical flow through mechanosensitive ion channels. Finally, adherence of monocytes is effectively reduced under helical flow conditions in an inflammatory environment, highlighting the atheroprotective role of helical flow. STATEMENT OF SIGNIFICANCE: Helical flow in blood vessels is well known to prevent atherosclerosis. However, despite efforts to replicate helical flow in microscale channels, there is still a lack of in vitro models which can generate helical flow for analyzing its effects on the vascular system. In this study, we developed a method for generating steady and constant helical flow in microfluidic channel using acoustofluidic techniques. By utilizing this dynamic flow generator, we were able to observe the atheroprotective aspects of helical flow in vitro, including the enhancement of calcium ion flux and reduction of monocyte adhesion. This study paves the way for an in vitro model of dynamic cell culture and offers advanced investigation into helical flow in our circulatory system.
Collapse
Affiliation(s)
- Daesik Kwak
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - Yongtaek Im
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - Hyeono Nam
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - Ungsig Nam
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - Seunggyu Kim
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - Woohyuk Kim
- School of Mechanical Engineering, Chonnam National University, Gwangju 61186, Republic of Korea
| | - Hyun Jin Kim
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - Jinsoo Park
- School of Mechanical Engineering, Chonnam National University, Gwangju 61186, Republic of Korea
| | - Jessie S Jeon
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea.
| |
Collapse
|
4
|
Sache A, Reymond P, Brina O, Jung B, Farhat M, Vargas MI. Near-wall hemodynamic parameters quantification in in vitro intracranial aneurysms with 7 T PC-MRI. MAGMA (NEW YORK, N.Y.) 2023; 36:295-308. [PMID: 37072539 PMCID: PMC10140017 DOI: 10.1007/s10334-023-01082-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Revised: 03/20/2023] [Accepted: 03/21/2023] [Indexed: 04/20/2023]
Abstract
OBJECTIVE Wall shear stress (WSS) and its derived spatiotemporal parameters have proven to play a major role on intracranial aneurysms (IAs) growth and rupture. This study aims to demonstrate how ultra-high field (UHF) 7 T phase contrast magnetic resonance imaging (PC-MRI) coupled with advanced image acceleration techniques allows a highly resolved visualization of near-wall hemodynamic parameters patterns in in vitro IAs, paving the way for more robust risk assessment of their growth and rupture. MATERIALS AND METHODS We performed pulsatile flow measurements inside three in vitro models of patient-specific IAs using 7 T PC-MRI. To this end, we built an MRI-compatible test bench, which faithfully reproduced a typical physiological intracranial flow rate in the models. RESULTS The ultra-high field 7 T images revealed WSS patterns with high spatiotemporal resolution. Interestingly, the high oscillatory shear index values were found in the core of low WSS vortical structures and in flow stream intersecting regions. In contrast, maxima of WSS occurred around the impinging jet sites. CONCLUSIONS We showed that the elevated signal-to-noise ratio arising from 7 T PC-MRI enabled to resolve high and low WSS patterns with a high degree of detail.
Collapse
Affiliation(s)
- Antoine Sache
- Department of Mechanical Engineering, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
| | - Philippe Reymond
- Division of Neuroradiology, Geneva University Hospital, University of Geneva, Geneva, Switzerland
| | - Olivier Brina
- Division of Neuroradiology, Geneva University Hospital, University of Geneva, Geneva, Switzerland
| | - Bernd Jung
- Department of Diagnostic, Interventional and Paediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Mohamed Farhat
- Department of Mechanical Engineering, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Maria Isabel Vargas
- Division of Neuroradiology, Geneva University Hospital, University of Geneva, Geneva, Switzerland
| |
Collapse
|
5
|
Roos PR, Rijnberg FM, Westenberg JJM, Lamb HJ. Particle Tracing Based on
4D
Flow Magnetic Resonance Imaging: A Systematic Review into Methods, Applications, and Current Developments. J Magn Reson Imaging 2022; 57:1320-1339. [PMID: 36484213 DOI: 10.1002/jmri.28540] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 11/15/2022] [Accepted: 11/15/2022] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND Particle tracing based on 4D Flow MRI has been applied as a quantitative and qualitative postprocessing technique to study temporally evolving blood flow patterns. PURPOSE To systematically review the various methods to perform 4D Flow MRI-based particle tracing, as well as the clinical value, clinical applications, and current developments of the technique. STUDY TYPE The study type is systematic review. SUBJECTS Patients with cardiovascular disease (such as Marfan, Fontan, Tetralogy of Fallot), healthy controls, and cardiovascular phantoms that received 4D Flow MRI with particle tracing. FIELD STRENGTH/SEQUENCE Three-dimensional three-directional cine phase-contrast MRI, at 1.5 T and 3 T. ASSESSMENT Two systematic searches were performed on the PubMed database using Boolean operators and the relevant key terms covering 4D Flow MRI and particle tracing. One systematic search was focused on particle tracing methods, whereas the other on applications. Additional articles from other sources were sought out and included after a similar inspection. Particle tracing methods, clinical applications, clinical value, and current developments were extracted. STATISTICAL TESTS The main results of the included studies are summarized, without additional statistical analysis. RESULTS Of 127 unique articles retrieved from the initial search, 56 were included (28 for methods and 54 for applications). Most articles that described particle tracing methods used an adaptive timestep, a fourth order Runge-Kutta integration method, and linear interpolation in the time dimension. Particle tracing was applied in heart chambers, aorta, venae cavae, Fontan circulation, pulmonary arteries, abdominal vasculature, peripheral arteries, carotid arteries, and cerebral vasculature. Applications were grouped as intravascular, intracardiac, flow stasis, and research. DATA CONCLUSIONS Particle tracing based on 4D Flow MRI gives unique insight into blood flow in several cardiovascular diseases, but the quality depends heavily on the MRI data quality. Further studies are required to evaluate the clinical value of the technique for different cardiovascular diseases. EVIDENCE LEVEL 5. TECHNICAL EFFICACY Stage 1.
Collapse
Affiliation(s)
- Paul R. Roos
- Department of Radiology Leiden University Medical Center Leiden The Netherlands
| | - Friso M. Rijnberg
- Department of Cardiothoracic Surgery Leiden University Medical Center Leiden The Netherlands
| | | | - Hildo J. Lamb
- Department of Radiology Leiden University Medical Center Leiden The Netherlands
| |
Collapse
|
6
|
Englund EK, Reiter DA, Shahidi B, Sigmund EE. Intravoxel Incoherent Motion Magnetic Resonance Imaging in Skeletal Muscle: Review and Future Directions. J Magn Reson Imaging 2022; 55:988-1012. [PMID: 34390617 PMCID: PMC8841570 DOI: 10.1002/jmri.27875] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 07/23/2021] [Accepted: 07/26/2021] [Indexed: 12/29/2022] Open
Abstract
Throughout the body, muscle structure and function can be interrogated using a variety of noninvasive magnetic resonance imaging (MRI) methods. Recently, intravoxel incoherent motion (IVIM) MRI has gained momentum as a method to evaluate components of blood flow and tissue diffusion simultaneously. Much of the prior research has focused on highly vascularized organs, including the brain, kidney, and liver. Unique aspects of skeletal muscle, including the relatively low perfusion at rest and large dynamic range of perfusion between resting and maximal hyperemic states, may influence the acquisition, postprocessing, and interpretation of IVIM data. Here, we introduce several of those unique features of skeletal muscle; review existing studies of IVIM in skeletal muscle at rest, in response to exercise, and in disease states; and consider possible confounds that should be addressed for muscle-specific evaluations. Most studies used segmented nonlinear least squares fitting with a b-value threshold of 200 sec/mm2 to obtain IVIM parameters of perfusion fraction (f), pseudo-diffusion coefficient (D*), and diffusion coefficient (D). In healthy individuals, across all muscles, the average ± standard deviation of D was 1.46 ± 0.30 × 10-3 mm2 /sec, D* was 29.7 ± 38.1 × 10-3 mm2 /sec, and f was 11.1 ± 6.7%. Comparisons of reported IVIM parameters in muscles of the back, thigh, and leg of healthy individuals showed no significant difference between anatomic locations. Throughout the body, exercise elicited a positive change of all IVIM parameters. Future directions including advanced postprocessing models and potential sequence modifications are discussed. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Erin K. Englund
- Department of Radiology, University of Colorado Anschutz Medical Campus
| | | | | | - Eric E. Sigmund
- Department of Radiology, New York University Grossman School of Medicine, NYU Langone Health
- Center for Advanced Imaging and Innovation (CAIR), Bernard and Irene Schwarz Center for Biomedical Imaging (CBI), NYU Langone Health
| |
Collapse
|
7
|
Blood Flow Quantification in Peripheral Arterial Disease: Emerging Diagnostic Techniques in Vascular Surgery. Surg Technol Int 2021. [PMID: 33970476 DOI: 10.52198/21.sti.38.cv1410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The assessment of local blood flow patterns in patients with peripheral arterial disease is clinically relevant, since these patterns are related to atherosclerotic disease progression and loss of patency in stents placed in peripheral arteries, through mechanisms such as recirculating flow and low wall shear stress (WSS). However, imaging of vascular flow in these patients is technically challenging due to the often complex flow patterns that occur near atherosclerotic lesions. While several flow quantification techniques have been developed that could improve the outcomes of vascular interventions, accurate 2D or 3D blood flow quantification is not yet used in clinical practice. This article provides an overview of several important topics that concern the quantification of blood flow in patients with peripheral arterial disease. The hemodynamic mechanisms involved in the development of atherosclerosis and the current clinical practice in the diagnosis of this disease are discussed, showing the unmet need for improved and validated flow quantification techniques in daily clinical practice. This discussion is followed by a showcase of state-of-the-art blood flow quantification techniques and how these could be used before, during and after treatment of stenotic lesions to improve clinical outcomes. These techniques include novel ultrasound-based methods, Phase-Contrast Magnetic Resonance Imaging (PC-MRI) and Computational Fluid Dynamics (CFD). The last section discusses future perspectives, with advanced (hybrid) imaging techniques and artificial intelligence, including the implementation of these techniques in clinical practice.
Collapse
|
8
|
Engelhard S, van de Velde L, Jebbink E, Jain K, Westenberg J, Zeebregts C, Versluis M, Reijnen M. Blood Flow Quantification in Peripheral Arterial Disease: Emerging Diagnostic Techniques in Vascular Surgery. Surg Technol Int 2021. [DOI: https:/doi.org/10.52198/21.sti.38.cv1410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2023]
Abstract
The assessment of local blood flow patterns in patients with peripheral arterial disease is clinically relevant, since these patterns are related to atherosclerotic disease progression and loss of patency in stents placed in peripheral arteries, through mechanisms such as recirculating flow and low wall shear stress (WSS). However, imaging of vascular flow in these patients is technically challenging due to the often complex flow patterns that occur near atherosclerotic lesions. While several flow quantification techniques have been developed that could improve the outcomes of vascular interventions, accurate 2D or 3D blood flow quantification is not yet used in clinical practice. This article provides an overview of several important topics that concern the quantification of blood flow in patients with peripheral arterial disease. The hemodynamic mechanisms involved in the development of atherosclerosis and the current clinical practice in the diagnosis of this disease are discussed, showing the unmet need for improved and validated flow quantification techniques in daily clinical practice. This discussion is followed by a showcase of state-of-the-art blood flow quantification techniques and how these could be used before, during and after treatment of stenotic lesions to improve clinical outcomes. These techniques include novel ultrasound-based methods, Phase-Contrast Magnetic Resonance Imaging (PC-MRI) and Computational Fluid Dynamics (CFD). The last section discusses future perspectives, with advanced (hybrid) imaging techniques and artificial intelligence, including the implementation of these techniques in clinical practice.
Collapse
Affiliation(s)
- Stefan Engelhard
- Department of Vascular Surgery, Rijnstate, Arnhem, The Netherlands
| | | | - Erik Jebbink
- Department of Vascular Surgery, Rijnstate, Arnhem, The Netherlands
| | - Kartik Jain
- Department of Thermal and Fluid Engineering, University of Twente, Enschede, The Netherlands
| | - Jos Westenberg
- Department of Radiology, Cardiovascular Imaging Group, Leiden University Medical Center, Leiden, The Netherlands
| | - Clark Zeebregts
- Department of Surgery (Division of Vascular Surgery), University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Michel Versluis
- Physics of Fluids Group, Technical Medical (TechMed) Centre, University of Twente, Enschede, The Netherlands
| | - Michel Reijnen
- Department of Vascular Surgery, Rijnstate, Arnhem, The Netherlands
| |
Collapse
|
9
|
Four-dimensional-flow Magnetic Resonance Imaging of the Aortic Valve and Thoracic Aorta. Radiol Clin North Am 2020; 58:753-763. [PMID: 32471542 DOI: 10.1016/j.rcl.2020.02.008] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Blood flow through the heart and great vessels is sensitive to time and multiple velocity directions. The assessment of its three-dimensional nature has been limited. Recent advances in magnetic resonance imaging (MRI) allow the comprehensive visualization and quantification of in vivo flow dynamics using four-dimensional (4D)-flow MRI. In addition, the technique provides the opportunity to obtain advanced hemodynamic measures. This article introduces 4D-flow MRI as it is currently used for blood flow visualization and quantification of cardiac hemodynamic parameters. It discusses its advantages relative to other flow MRI techniques and describes its potential clinical applications.
Collapse
|
10
|
Englund EK, Langham MC. Quantitative and Dynamic MRI Measures of Peripheral Vascular Function. Front Physiol 2020; 11:120. [PMID: 32184733 PMCID: PMC7058683 DOI: 10.3389/fphys.2020.00120] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2019] [Accepted: 02/03/2020] [Indexed: 12/31/2022] Open
Abstract
The endothelium regulates and mediates vascular homeostasis, allowing for dynamic changes of blood flow in response to mechanical and chemical stimuli. Endothelial dysfunction underlies many diseases and is purported to be the earliest pathologic change in the progression of atherosclerotic disease. Peripheral vascular function can be interrogated by measuring the response kinetics following induced ischemia or exercise. In the presence of endothelial dysfunction, there is a blunting and delay of the hyperemic response, which can be measured non-invasively using a variety of quantitative magnetic resonance imaging (MRI) methods. In this review, we summarize recent developments in non-contrast, proton MRI for dynamic quantification of blood flow and oxygenation. Methodologic description is provided for: blood oxygenation-level dependent (BOLD) signal that reflect combined effect of blood flow and capillary bed oxygen content; arterial spin labeling (ASL) for quantification of regional perfusion; phase contrast (PC) to quantify arterial flow waveforms and macrovascular blood flow velocity and rate; high-resolution MRI for luminal flow-mediated dilation; and dynamic MR oximetry to quantify oxygen saturation. Overall, results suggest that these dynamic and quantitative MRI methods can detect endothelial dysfunction both in the presence of overt cardiovascular disease (such as in patients with peripheral artery disease), as well as in sub-clinical settings (i.e., in chronic smokers, non-smokers exposed to e-cigarette aerosol, and as a function of age). Thus far, these tools have been relegated to the realm of research, used as biomarkers of disease progression and therapeutic response. With proper validation, MRI-measures of vascular function may ultimately be used to complement the standard clinical workup, providing additional insight into the optimal treatment strategy and evaluation of treatment efficacy.
Collapse
Affiliation(s)
- Erin K Englund
- Department of Orthopaedic Surgery, University of California, San Diego, La Jolla, CA, United States
| | - Michael C Langham
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| |
Collapse
|
11
|
Calo K, Gallo D, Steinman DA, Mazzi V, Scarsoglio S, Ridolfi L, Morbiducci U. Spatiotemporal Hemodynamic Complexity in Carotid Arteries: An Integrated Computational Hemodynamics and Complex Networks-Based Approach. IEEE Trans Biomed Eng 2019; 67:1841-1853. [PMID: 31647419 DOI: 10.1109/tbme.2019.2949148] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVE The study of the arterial hemodynamics is essential for a better understanding of the risks associated with the onset/progression of vascular disease. However, conventional quantification and visualization paradigms are not sufficient to fully capture the spatiotemporal evolution of correlated blood flow patterns and their "sphere of influence" in complex vascular geometries. In the attempt to bridge this knowledge gap, an integrated computational hemodynamics and complex networks-based approach is proposed to unveil organization principles of cardiovascular flows. METHODS The approach is applied to ten patient-specific hemodynamic models of carotid bifurcation, a vascular bed characterized by a complex hemodynamics and clinically-relevant disease. Correlation-based networks are built starting from time-histories of two fluid mechanics quantities of physiological significance, respectively (1) the blood velocity vector axial component locally aligned with the main flow direction, and (2) the kinetic helicity density. RESULTS Unlike conventional hemodynamic analyses, here the spatiotemporal similarity of dynamic intravascular flow structures is encoded in a distance function. In the case of the carotid bifurcation, this study measures for the first time to what extent flow similarity is disrupted by vascular geometric features. CONCLUSION It emerges that a larger bifurcation expansion, a hallmark of vascular disease, significantly disrupts the network topological connections between axial flow structures, reducing also their anatomical persistence length. On the contrary, connections in helical flow patterns are overall less geometry-sensitive. SIGNIFICANCE The integrated approach proposed here, by exploiting the connections of hemodynamic patterns undergoing similar dynamical evolution, opens avenues for further comprehension of vascular physiopathology.
Collapse
|
12
|
|
13
|
Aherne EA, Koktzoglou I, Lind BB, Edelman RR. Dynamic quantitative nonenhanced magnetic resonance angiography of the abdominal aorta and lower extremities using cine fast interrupted steady-state in combination with arterial spin labeling: a feasibility study. J Cardiovasc Magn Reson 2019; 21:55. [PMID: 31474219 PMCID: PMC6717984 DOI: 10.1186/s12968-019-0562-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Accepted: 07/15/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Cine fast interrupted steady-state in combination with arterial spin labeling is a recently described nonenhanced magnetic resonance angiography (MRA) technique that relies on bolus tracking for time-resolved digital subtraction angiography-like displays of blood flow patterns. We evaluated the feasibility of applying this technique to display in-plane flow patterns in two regions: the abdominal aorta and lower extremity peripheral arteries. METHODS We performed an institutional review board-approved study in healthy subjects and patients. In 7 healthy subjects, in-plane flow was imaged at 4 stations ranging from the lower legs to the aorto-iliac bifurcation (junction of the distal thigh and upper calf, mid-thigh, junction of the upper thigh and pelvis, upper pelvis). In 5 healthy subjects and 6 patients without abdominal aortopathy, images were acquired through the suprarenal abdominal aorta. Ten patients with known peripheral arterial disease and two patients with stable disease of the abdominal aorta were also evaluated. Peak velocity was compared at each of the 4 stations for cine fast interrupted steady-state in combination with arterial spin labeling and two-dimensional cine phase contrast in patients with normal vessels. RESULTS In-plane flow patterns were well visualized in all peripheral arterial stations and in the abdominal aorta, providing a high quality display of hemodynamic patterns along extensive lengths of the vessels. There was very strong positive correlation (r = 0.952, P < 0.05) and excellent agreement (intraclass correlation coefficient, 0.935; 95% confidence interval, 0.812-0.972) between peak flow velocities measured by cine fast interrupted steady-state in combination with arterial spin labeling and two-dimensional cine phase contrast. In 10 patients with peripheral artery disease and 2 patients with aortic pathology, cine fast interrupted steady-state in combination with arterial spin labeling provided a visual demonstration of abnormal hemodynamics. CONCLUSION This feasibility study suggests that cine fast interrupted steady-state in combination with arterial spin labeling provides an efficient, high quality and physiologically accurate display of in-plane flow patterns over extensive lengths of the lower extremity peripheral arteries, which can be difficult to achieve using other MRA techniques.
Collapse
Affiliation(s)
- Emily A. Aherne
- Department of Radiology, NorthShore University HealthSystem, Walgreen Building, G507 2650 Ridge Ave, Evanston, USA
- McGaw Medical Center of Northwestern University, 2650 Ridge Ave Evanston, Chicago, IL 60201 USA
| | - Ioannis Koktzoglou
- Department of Radiology, NorthShore University HealthSystem, Walgreen Building, G507 2650 Ridge Ave, Evanston, USA
- University of Chicago Pritzker School of Medicine, Chicago, USA
| | - Benjamin B. Lind
- Department of Surgery, NorthShore University HealthSystem, 9650 Gross Point Rd Ste 4900, Skokie, Evanston, IL 60076 USA
| | - Robert R. Edelman
- Department of Radiology, NorthShore University HealthSystem, Walgreen Building, G507 2650 Ridge Ave, Evanston, USA
- Northwestern University Feinberg School of Medicine, Chicago, USA
| |
Collapse
|
14
|
Miceli M, Baldi D, Cavaliere C, Soricelli A, Salvatore M, Napoli C. Peripheral artery disease: the new frontiers of imaging techniques to evaluate the evolution of regenerative medicine. Expert Rev Cardiovasc Ther 2019; 17:511-532. [PMID: 31220944 DOI: 10.1080/14779072.2019.1635012] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Introduction: Stem cells (ESC, iPSC, MSC) are known to have intrinsic regenerative properties. In the last decades numerous findings have favored the development of innovative therapeutic protocols based on the use of stem cells (Regenerative Medicine/Cell Therapy) for the treatment of numerous diseases including PAD, with promising results in preclinical studies. So far, several clinical studies have shown a general improvement of the patient's clinical outcome, however they possess many critical issues caused by the non-randomized design of the limited number of patients examined, the type cells to be used, their dosage, the short duration of treatment and also their delivery strategy. Areas covered: In this context, the use of the most advanced molecular imaging techniques will allow the visualization of very important physio-pathological processes otherwise invisible with conventional techniques, such as angiogenesis, also providing important structural and functional data. Expert opinion: The new frontier of cell therapy applied to PAD, potentially able to stop or even the process that causes the disease, with particular emphasis on the clinical aspects that different types of cells involve and on the use of more innovative molecular imaging techniques now available.
Collapse
Affiliation(s)
| | | | | | - Andrea Soricelli
- a IRCCS SDN , Naples , Italy.,b Department of Exercise and Wellness Sciences , University of Naples Parthenope , Naples , Italy
| | | | - Claudio Napoli
- a IRCCS SDN , Naples , Italy.,c University Department of Advanced Medical and Surgical Sciences, Clinical Department of Internal Medicine and Specialty Medicine , Università degli Studi della Campania 'Luigi Vanvitelli' , Napes , Italy
| |
Collapse
|
15
|
The Atheroprotective Nature of Helical Flow in Coronary Arteries. Ann Biomed Eng 2018; 47:425-438. [DOI: 10.1007/s10439-018-02169-x] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2018] [Accepted: 11/15/2018] [Indexed: 12/20/2022]
|
16
|
Li Y, Shi G, Du J, Wang J, Bian P. Analysis and preparation of rotational flow mechanism of artificial blood vessel with spiral folds on inner wall. Biomech Model Mechanobiol 2018; 18:411-423. [DOI: 10.1007/s10237-018-1092-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2018] [Accepted: 10/29/2018] [Indexed: 10/27/2022]
|
17
|
Mathew RC, Kramer CM. Recent advances in magnetic resonance imaging for peripheral artery disease. Vasc Med 2018; 23:143-152. [PMID: 29633922 DOI: 10.1177/1358863x18754694] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The global burden of peripheral artery disease (PAD) is significant. This has led to numerous recent advances in magnetic resonance imaging (MRI) techniques in PAD. Older techniques such as time of flight MRI or phase contrast MRI are burdened by long acquisition times and significant issues with artifacts. In addition, the most used MRI modality, contrast-enhanced MR angiography (CE-MRA) is limited by the use of gadolinium contrast and its potential toxicity. Novel MRI techniques such as arterial spin labeling (ASL), blood-oxygen-level dependent imaging (BOLD), and first-pass perfusion gadolinium enhancement are advancing the field by providing skeletal muscle perfusion/oxygenation data while maintaining excellent spatial and temporal resolution. Perfusion data can be critical to providing objective clinical data of a visualized stenosis. In addition, there are a number of new MRI sequences assessing plaque composition and lesion severity in the absence of contrast. These approaches used in combination can provide useful clinical and prognostic data and provide critical endpoints in PAD research.
Collapse
Affiliation(s)
- Roshin C Mathew
- Departments of Medicine (Cardiology) and Radiology, University of Virginia Health System, Charlottesville, VA, USA
| | - Christopher M Kramer
- Departments of Medicine (Cardiology) and Radiology, University of Virginia Health System, Charlottesville, VA, USA
| |
Collapse
|
18
|
Takei Y, Itatani K, Miyazaki S, Shibasaki I, Fukuda H. Four-dimensional flow magnetic resonance imaging analysis before and after thoracic endovascular aortic repair of chronic type B aortic dissection. Interact Cardiovasc Thorac Surg 2018; 28:413-420. [DOI: 10.1093/icvts/ivy271] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Revised: 07/27/2018] [Accepted: 07/31/2018] [Indexed: 01/24/2023] Open
Affiliation(s)
- Yusuke Takei
- Department of Cardiac and Vascular Surgery, Dokkyo Medical University Hospital, Mibu-Machi, Tochigi, Japan
| | | | | | - Ikuko Shibasaki
- Department of Cardiac and Vascular Surgery, Dokkyo Medical University Hospital, Mibu-Machi, Tochigi, Japan
| | - Hirotsugu Fukuda
- Department of Cardiac and Vascular Surgery, Dokkyo Medical University Hospital, Mibu-Machi, Tochigi, Japan
| |
Collapse
|
19
|
Siedek F, Giese D, Weiss K, Ekdawi S, Brinkmann S, Schroeder W, Bruns C, Chang DH, Persigehl T, Maintz D, Haneder S. 4D flow MRI for the analysis of celiac trunk and mesenteric artery stenoses. Magn Reson Imaging 2018; 53:52-62. [PMID: 30008436 DOI: 10.1016/j.mri.2018.06.021] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2018] [Revised: 05/31/2018] [Accepted: 06/28/2018] [Indexed: 01/13/2023]
Abstract
PURPOSE This study aims to assess the feasibility of 4D flow MRI measurements in complex vascular territories; namely, the celiac artery (CA) and superior mesenteric artery (SMA). MATERIALS AND METHODS In this prospective study, 22 healthy volunteers and 10 patients were scanned at 3 T. Blood flow parameters were compared between healthy volunteers and patients with stenosis of the CA and/or SMA as a function of stenosis grade characterized by prior contrast-enhanced computed tomography (CE-CT). The 4D flow MRI acquisition covered the CA, SMA and adjusting parts of the abdominal aorta (AO). Measurements of velocity- (peak velocity [PV], average velocity [AV]) and volume-related parameters (peak flow [PF], stroke volume [SV]) were conducted. Further, stenosis grade and wall shear stress in the CA, SMA and AO were evaluated. RESULTS In patients, prior evaluation by CE-CT revealed 11 low- and 5 mid-grade stenoses of the CA and/or SMA. PV and AV were significantly higher in patients than in healthy volunteers [PV: p < 0.0001; AV: p = 0.03, p < 0.001]. PF and SV did not differ significantly between healthy volunteers and patients; however, a trend towards lower PF and SV could be detected in patients with mid-grade stenoses. Comparison of 4D flow MRI with CE-CT revealed a strong positive correlation in estimated degree of stenosis (CA: r = 0.86, SMA: r = 0.98). Patients with mid-grade stenoses had a significantly higher average WSS magnitude (AWM) than healthy volunteers (p = 0.02). CONCLUSION This feasibility study suggests that 4D flow MRI is a viable technique for the evaluation of complex flow characteristics in small vessels such as the CA and SMA. 4D flow MRI approves comparable to the morphologic assessment of complex vascular territories using CE-CT but, in addition, offers the functional evaluation of flow parameters that goes beyond the morphology.
Collapse
Affiliation(s)
- Florian Siedek
- Institute of Diagnostic and Interventional Radiology, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany.
| | - Daniel Giese
- Institute of Diagnostic and Interventional Radiology, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Kilian Weiss
- Institute of Diagnostic and Interventional Radiology, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany; Philips Healthcare Germany, Hamburg, Germany
| | - Sandra Ekdawi
- Institute of Diagnostic and Interventional Radiology, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Sebastian Brinkmann
- Department of General, Visceral and Tumor Surgery, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Wolfgang Schroeder
- Department of General, Visceral and Tumor Surgery, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Christiane Bruns
- Department of General, Visceral and Tumor Surgery, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - De-Hua Chang
- Institute of Diagnostic and Interventional Radiology, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Thorsten Persigehl
- Institute of Diagnostic and Interventional Radiology, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - David Maintz
- Institute of Diagnostic and Interventional Radiology, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Stefan Haneder
- Institute of Diagnostic and Interventional Radiology, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| |
Collapse
|
20
|
Ota H, Higuchi S, Sun W, Ueda T, Takase K, Tamura H. Four-Dimensional Flow Magnetic Resonance Imaging for Cardiovascular Imaging: from Basic Concept to Clinical Application. ACTA ACUST UNITED AC 2018. [DOI: 10.22468/cvia.2018.00045] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- Hideki Ota
- Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Japan
| | - Satoshi Higuchi
- Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Japan
| | - Wenyu Sun
- Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Japan
| | - Takuya Ueda
- Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Japan
| | - Kei Takase
- Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Japan
| | - Hajime Tamura
- Division of Medical Physics, Tohoku University Graduate School of Medicine, Sendai, Japan
| |
Collapse
|
21
|
Ruiz-Soler A, Kabinejadian F, Slevin MA, Bartolo PJ, Keshmiri A. Optimisation of a Novel Spiral-Inducing Bypass Graft Using Computational Fluid Dynamics. Sci Rep 2017; 7:1865. [PMID: 28500311 PMCID: PMC5431846 DOI: 10.1038/s41598-017-01930-x] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2016] [Accepted: 04/06/2017] [Indexed: 11/09/2022] Open
Abstract
Graft failure is currently a major concern for medical practitioners in treating Peripheral Vascular Disease (PVD) and Coronary Artery Disease (CAD). It is now widely accepted that unfavourable haemodynamic conditions play an essential role in the formation and development of intimal hyperplasia, which is the main cause of graft failure. This paper uses Computational Fluid Dynamics (CFD) to conduct a parametric study to enhance the design and performance of a novel prosthetic graft, which utilises internal ridge(s) to induce spiral flow. This design is primarily based on the identification of the blood flow as spiral in the whole arterial system and is believed to improve the graft longevity and patency rates at distal graft anastomoses. Four different design parameters were assessed in this work and the trailing edge orientation of the ridge was identified as the most important parameter to induce physiological swirling flow, while the height of the ridge also significantly contributed to the enhanced performance of this type of graft. Building on these conclusions, an enhanced configuration of spiral graft is proposed and compared against conventional and spiral grafts to reaffirm its potential benefits.
Collapse
Affiliation(s)
- Andres Ruiz-Soler
- Engineering and Materials Research Centre, Manchester Metropolitan University, Manchester, M1 5GD, UK.,School of Mechanical, Aerospace and Civil Engineering (MACE), The University of Manchester, Manchester, M13 9PL, UK
| | - Foad Kabinejadian
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, 48109-2110, USA
| | - Mark A Slevin
- Healthcare Science Research Centre, Manchester Metropolitan University, Manchester, M1 5GD, UK
| | - Paulo J Bartolo
- School of Mechanical, Aerospace and Civil Engineering (MACE), The University of Manchester, Manchester, M13 9PL, UK
| | - Amir Keshmiri
- School of Mechanical, Aerospace and Civil Engineering (MACE), The University of Manchester, Manchester, M13 9PL, UK.
| |
Collapse
|
22
|
Miyazaki S, Itatani K, Furusawa T, Nishino T, Sugiyama M, Takehara Y, Yasukochi S. Validation of numerical simulation methods in aortic arch using 4D Flow MRI. Heart Vessels 2017; 32:1032-1044. [PMID: 28444501 PMCID: PMC5519664 DOI: 10.1007/s00380-017-0979-2] [Citation(s) in RCA: 67] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2016] [Accepted: 04/14/2017] [Indexed: 11/20/2022]
Abstract
Computational fluid dynamics (CFD) are the gold standard in studying blood flow dynamics. However, CFD results are dependent on the boundary conditions and the computation model. The purpose of this study was to validate CFD methods using comparison with actual measurements of the blood flow vector obtained with four-dimensional (4D) flow magnetic resonance imaging (MRI). 4D Flow MRI was performed on a healthy adult and a child with double-aortic arch. The aortic lumen was segmented to visualize the blood flow. The CFD analyses were performed for the same geometries based on three turbulent models: laminar, large eddy simulation (LES), and the renormalization group k–ε model (RNG k–ε). The flow-velocity vector components, namely the wall shear stress (WSS) and flow energy loss (EL), of the MRI and CFD results were compared. The flow rate of the MRI results was underestimated in small vessels, including the neck vessels. Spiral flow in the ascending aorta caused by the left ventricular twist was observed by MRI. Secondary flow distal to the aortic arch was well realized in both CFD and MRI. The average correlation coefficients of the velocity vector components of MRI and CFD for the child were the highest for the RNG k–ε model (0.530 in ascending aorta, 0.768 in the aortic arch, 0.584 in the descending aorta). The WSS and EL values of MRI were less than half of those of CFD, but the WSS distribution patterns were quite similar. The WSS and EL estimates were higher in RNG k–ε and LES than in the laminar model because of eddy viscosity. The CFD computation realized accurate flow distal to the aortic arch, and the WSS distribution was well simulated compared to actual measurement using 4D Flow MRI. However, the helical flow was not simulated in the ascending aorta. The accuracy was enhanced by using the turbulence model, and the RNG k–ε model showed the highest correlation with 4D Flow MRI.
Collapse
Affiliation(s)
- Shohei Miyazaki
- Cardio Flow Design, Inc., Chiyoda, Tokyo, Japan.,Department of Cardiovascular Surgery, Kyoto Prefectural University of Medicine, 1-5 Hangi-cho, Shimogamo, Sakyo-ku, Kyoto, 606-8522, Japan
| | - Keiichi Itatani
- Cardio Flow Design, Inc., Chiyoda, Tokyo, Japan. .,Department of Cardiovascular Surgery, Kyoto Prefectural University of Medicine, 1-5 Hangi-cho, Shimogamo, Sakyo-ku, Kyoto, 606-8522, Japan.
| | | | | | - Masataka Sugiyama
- Department of Radiology, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| | - Yasuo Takehara
- Department of Radiology, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| | - Satoshi Yasukochi
- Department of Pediatric Cardiology, Nagano Children's Hospital, Azumino, Nagano, Japan
| |
Collapse
|
23
|
Spiral Laminar Flow: a Survey of a Three-Dimensional Arterial Flow Pattern in a Group of Volunteers. Eur J Vasc Endovasc Surg 2016; 52:674-680. [DOI: 10.1016/j.ejvs.2016.07.018] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2015] [Accepted: 07/16/2016] [Indexed: 11/18/2022]
|
24
|
Goldberg A, Halandras PM, Shea S, Cho JS. Utility of magnetic resonance imaging in establishing a venous pressure gradient in a patient with possible nutcracker syndrome. J Vasc Surg Cases Innov Tech 2016; 2:80-83. [PMID: 38827195 PMCID: PMC11140380 DOI: 10.1016/j.jvsc.2016.03.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2016] [Accepted: 03/19/2016] [Indexed: 10/21/2022] Open
Abstract
Nutcracker syndrome is characterized by abnormal acute angulation of the superior mesenteric artery origin from the aorta, with resulting compression and hypertension of the crossing left renal vein. The radiologic studies used in diagnosis are typically limited to standard cross-sectional anatomic imaging with computed tomography or magnetic resonance imaging, with occasional use of Doppler ultrasound imaging for hemodynamic quantification. The standard for acquiring anatomic and physiologic information continues to be invasive venography. We describe the successful novel application of phase-encoded magnetic resonance imaging as a noninvasive method for acquiring anatomic and hemodynamic data in a case of possible nutcracker syndrome in a young patient.
Collapse
Affiliation(s)
- Ari Goldberg
- Department of Radiology, Loyola University Chicago, Stritch School of Medicine, Maywood, Ill
| | - Pegge M. Halandras
- Department of Surgery, Loyola University Chicago, Stritch School of Medicine, Maywood, Ill
| | - Steven Shea
- Department of Radiology, Loyola University Chicago, Stritch School of Medicine, Maywood, Ill
| | - Jae S. Cho
- Department of Surgery, Loyola University Chicago, Stritch School of Medicine, Maywood, Ill
| |
Collapse
|
25
|
Englund EK, Rodgers ZB, Langham MC, Mohler ER, Floyd TF, Wehrli FW. Measurement of skeletal muscle perfusion dynamics with pseudo-continuous arterial spin labeling (pCASL): Assessment of relative labeling efficiency at rest and during hyperemia, and comparison to pulsed arterial spin labeling (PASL). J Magn Reson Imaging 2016; 44:929-39. [PMID: 27043039 DOI: 10.1002/jmri.25247] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2015] [Accepted: 03/04/2016] [Indexed: 12/21/2022] Open
Abstract
PURPOSE To compare calf skeletal muscle perfusion measured with pulsed arterial spin labeling (PASL) and pseudo-continuous arterial spin labeling (pCASL) methods, and to assess the variability of pCASL labeling efficiency in the popliteal artery throughout an ischemia-reperfusion paradigm. MATERIALS AND METHODS At 3T, relative pCASL labeling efficiency was experimentally assessed in five subjects by measuring the signal intensity of blood in the popliteal artery just distal to the labeling plane immediately following pCASL labeling or control preparation pulses, or without any preparation pulses throughout separate ischemia-reperfusion paradigms. The relative label and control efficiencies were determined during baseline, hyperemia, and recovery. In a separate cohort of 10 subjects, pCASL and PASL sequences were used to measure reactive hyperemia perfusion dynamics. RESULTS Calculated pCASL labeling and control efficiencies did not differ significantly between baseline and hyperemia or between hyperemia and recovery periods. Relative to the average baseline, pCASL label efficiency was 2 ± 9% lower during hyperemia. Perfusion dynamics measured with pCASL and PASL did not differ significantly (P > 0.05). Average leg muscle peak perfusion was 47 ± 20 mL/min/100g or 50 ± 12 mL/min/100g, and time to peak perfusion was 25 ± 3 seconds and 25 ± 7 seconds from pCASL and PASL data, respectively. Differences of further metrics parameterizing the perfusion time course were not significant between pCASL and PASL measurements (P > 0.05). CONCLUSION No change in pCASL labeling efficiency was detected despite the almost 10-fold increase in average blood flow velocity in the popliteal artery. pCASL and PASL provide precise and consistent measurement of skeletal muscle reactive hyperemia perfusion dynamics. J. MAGN. RESON. IMAGING 2016;44:929-939.
Collapse
Affiliation(s)
- Erin K Englund
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
| | - Zachary B Rodgers
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Michael C Langham
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Emile R Mohler
- Department of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Thomas F Floyd
- Department of Anesthesiology, Stony Brook University, Stony Brook, New York, USA
| | - Felix W Wehrli
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
26
|
Dyverfeldt P, Bissell M, Barker AJ, Bolger AF, Carlhäll CJ, Ebbers T, Francios CJ, Frydrychowicz A, Geiger J, Giese D, Hope MD, Kilner PJ, Kozerke S, Myerson S, Neubauer S, Wieben O, Markl M. 4D flow cardiovascular magnetic resonance consensus statement. J Cardiovasc Magn Reson 2015; 17:72. [PMID: 26257141 PMCID: PMC4530492 DOI: 10.1186/s12968-015-0174-5] [Citation(s) in RCA: 563] [Impact Index Per Article: 62.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2015] [Accepted: 07/17/2015] [Indexed: 02/07/2023] Open
Abstract
Pulsatile blood flow through the cavities of the heart and great vessels is time-varying and multidirectional. Access to all regions, phases and directions of cardiovascular flows has formerly been limited. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) has enabled more comprehensive access to such flows, with typical spatial resolution of 1.5×1.5×1.5 - 3×3×3 mm(3), typical temporal resolution of 30-40 ms, and acquisition times in the order of 5 to 25 min. This consensus paper is the work of physicists, physicians and biomedical engineers, active in the development and implementation of 4D Flow CMR, who have repeatedly met to share experience and ideas. The paper aims to assist understanding of acquisition and analysis methods, and their potential clinical applications with a focus on the heart and greater vessels. We describe that 4D Flow CMR can be clinically advantageous because placement of a single acquisition volume is straightforward and enables flow through any plane across it to be calculated retrospectively and with good accuracy. We also specify research and development goals that have yet to be satisfactorily achieved. Derived flow parameters, generally needing further development or validation for clinical use, include measurements of wall shear stress, pressure difference, turbulent kinetic energy, and intracardiac flow components. The dependence of measurement accuracy on acquisition parameters is considered, as are the uses of different visualization strategies for appropriate representation of time-varying multidirectional flow fields. Finally, we offer suggestions for more consistent, user-friendly implementation of 4D Flow CMR acquisition and data handling with a view to multicenter studies and more widespread adoption of the approach in routine clinical investigations.
Collapse
Affiliation(s)
- Petter Dyverfeldt
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.
| | - Malenka Bissell
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, UK.
| | - Alex J Barker
- Department of Radiology, Northwestern University, Chicago, USA.
| | - Ann F Bolger
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.
- Department of Medicine, University of California San Francisco, San Francisco, CA, United States.
| | - Carl-Johan Carlhäll
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.
- Department of Clinical Physiology, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
| | - Tino Ebbers
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.
| | | | - Alex Frydrychowicz
- Klinik für Radiologie und Nuklearmedizin, University Hospital Schleswig-Holstein, Campus Lübeck, Lübeck, Germany.
| | - Julia Geiger
- Department of Radiology, University Children's Hospital Zurich, Zurich, Switzerland.
| | - Daniel Giese
- Department of Radiology, University Hospital of Cologne, Cologne, Germany.
| | - Michael D Hope
- Department of Radiology, University of California San Francisco, San Francisco, CA, United States.
| | - Philip J Kilner
- NIHR Cardiovascular Biomedical Research Unit, Royal Brompton and Harefield NHS Foundation Trust, National Heart and Lung Institute, Imperial College, London, UK.
| | - Sebastian Kozerke
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland.
| | - Saul Myerson
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, UK.
| | - Stefan Neubauer
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, UK.
| | - Oliver Wieben
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA.
| | - Michael Markl
- Department of Radiology, Northwestern University, Chicago, USA.
- Department of Biomedical Engineering, Northwestern University, Chicago, IL, USA.
| |
Collapse
|
27
|
Nayak KS, Nielsen JF, Bernstein MA, Markl M, D Gatehouse P, M Botnar R, Saloner D, Lorenz C, Wen H, S Hu B, Epstein FH, N Oshinski J, Raman SV. Cardiovascular magnetic resonance phase contrast imaging. J Cardiovasc Magn Reson 2015; 17:71. [PMID: 26254979 PMCID: PMC4529988 DOI: 10.1186/s12968-015-0172-7] [Citation(s) in RCA: 154] [Impact Index Per Article: 17.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2015] [Accepted: 07/16/2015] [Indexed: 11/10/2022] Open
Abstract
Cardiovascular magnetic resonance (CMR) phase contrast imaging has undergone a wide range of changes with the development and availability of improved calibration procedures, visualization tools, and analysis methods. This article provides a comprehensive review of the current state-of-the-art in CMR phase contrast imaging methodology, clinical applications including summaries of past clinical performance, and emerging research and clinical applications that utilize today's latest technology.
Collapse
Affiliation(s)
- Krishna S Nayak
- Ming Hsieh Department of Electrical Engineering, University of Southern California, 3740 McClintock Ave, EEB 406, Los Angeles, California, 90089-2564, USA.
| | - Jon-Fredrik Nielsen
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
| | | | - Michael Markl
- Department of Radiology, Northwestern University, Chicago, IL, USA.
| | - Peter D Gatehouse
- Cardiovascular Biomedical Research Unit, Royal Brompton Hospital, London, UK.
| | - Rene M Botnar
- Cardiovascular Imaging, Imaging Sciences Division, Kings's College London, London, UK.
| | - David Saloner
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA.
| | - Christine Lorenz
- Center for Applied Medical Imaging, Siemens Corporation, Baltimore, MD, USA.
| | - Han Wen
- Imaging Physics Laboratory, National Heart Lung and Blood Institute, Bethesda, MD, USA.
| | - Bob S Hu
- Palo Alto Medical Foundation, Palo Alto, CA, USA.
| | - Frederick H Epstein
- Departments of Radiology and Biomedical Engineering, University of Virginia, Charlottesville, VA, USA.
| | - John N Oshinski
- Departments of Radiology and Biomedical Engineering, Emory University School of Medicine, Atlanta, GA, USA.
| | - Subha V Raman
- Division of Cardiovascular Medicine, The Ohio State University, Columbus, OH, USA.
| |
Collapse
|
28
|
MR Angiography at 3 T of Peripheral Arterial Disease: A Randomized Prospective Comparison of Gadoterate Meglumine and Gadobutrol. AJR Am J Roentgenol 2015; 204:1311-21. [PMID: 26001243 DOI: 10.2214/ajr.14.12604] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVE This large-scale randomized study aimed to show the noninferiority in terms of diagnostic performance of gadoterate meglumine-enhanced versus gadobutrol-enhanced 3-T MR angiography (MRA) using digital subtraction angiography (DSA) as the reference standard in patients with peripheral arterial occlusive disease (PAOD). SUBJECTS AND METHODS In this prospective international randomized double-blind phase IV trial, 189 patients were enrolled. Of them, 156 could be included in the per-protocol population for on-site assessments and 154 for off-site readings. Subjects underwent peripheral MRA, after injection of 0.1 mmol/kg of either gadoterate meglumine or gadobutrol, and DSA within 30 days. The diagnostic accuracy was evaluated and compared using a noninferiority analysis. Secondary endpoints included sensitivity, specificity, diagnostic confidence, contrast-to-noise ratio, and signal-to-noise ratio evaluations. RESULTS The percentage agreement between MRA and DSA for stenosis detection was similar for on-site readings for both groups (mean ± SD, 80.6% ± 16.1% with gadoterate meglumine vs 77.1% ± 19.6% with gadobutrol; 3.5% difference), and the same was true for off-site readings (73.9% ± 16.9% with gadoterate meglumine vs 75.1% ± 13.8% with gadobutrol; 1.1% difference). The noninferiority of gadoterate meglumine to gadobutrol was shown for both on- and off-site readings. Sensitivity in detecting significant stenosis (> 50%) was 72.3% for gadoterate meglumine versus 70.6% for gadobutrol, whereas specificity (92.6% vs 92.3%), diagnostic confidence (87.0% vs 86.0%), signal-to-noise ratio (165.5 vs 161.0), and contrast-to-noise ratio (159.5 vs 155.3) did not differ statistically significantly between the two groups. CONCLUSION Gadoterate meglumine was found to be not inferior to gadobutrol in terms of diagnostic performance in patients with PAOD undergoing 3-T contrast-enhanced MRA. No statistically significant differences were detected between the two MRA groups.
Collapse
|
29
|
Keegan J, Patel HC, Simpson RM, Mohiaddin RH, Firmin DN. Inter-study reproducibility of interleaved spiral phase velocity mapping of renal artery haemodynamics. J Cardiovasc Magn Reson 2015; 17:8. [PMID: 25648103 PMCID: PMC4316806 DOI: 10.1186/s12968-014-0105-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2014] [Accepted: 12/16/2014] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND Qualitative and quantitative assessment of renal blood flow is valuable in the evaluation of patients with renal and renovascular diseases as well as in patients with heart failure. The temporal pattern of renal flow velocity through the cardiac cycle provides important information about renal haemodynamics. High temporal resolution interleaved spiral phase velocity mapping could potentially be used to study temporal patterns of flow and measure resistive and pulsatility indices which are measures of downstream resistance. METHODS A retrospectively gated breath-hold spiral phase velocity mapping sequence (TR 19 ms) was developed at 3 Tesla. Phase velocity maps were acquired in the proximal right and left arteries of 10 healthy subjects in each of two separate scanning sessions. Each acquisition was analysed by two independent observers who calculated the resistive index (RI), the pulsatility index (PI), the mean flow velocity and the renal artery blood flow (RABF). Inter-study and inter-observer reproducibility of each variable was determined as the mean +/- standard deviation of the differences between paired values. The effect of background phase errors on each parameter was investigated. RESULTS RI, PI, mean velocity and RABF per kidney were 0.71+/- 0.06, 1.47 +/- 0.29, 253.5 +/- 65.2 mm/s and 413 +/- 122 ml/min respectively. The inter-study reproducibilities were: RI -0.00 +/- 0.04 , PI -0.03 +/- 0.17, mean velocity -6.7 +/- 31.1 mm/s and RABF per kidney 17.9 +/- 44.8 ml/min. The effect of background phase errors was negligible (<2% for each parameter). CONCLUSIONS High temporal resolution breath-hold spiral phase velocity mapping allows reproducible assessment of renal pulsatility indices and RABF.
Collapse
Affiliation(s)
- Jennifer Keegan
- />Cardiovascular Magnetic Resonance, Royal Brompton Hospital, Sydney Street, London, SW3 6NP UK
| | - Hitesh C Patel
- />Cardiovascular Magnetic Resonance, Royal Brompton Hospital, Sydney Street, London, SW3 6NP UK
| | - Robin M Simpson
- />Cardiovascular Magnetic Resonance, Royal Brompton Hospital, Sydney Street, London, SW3 6NP UK
- />Radiological Physics, University of Freiburg, Freiburg, Germany
| | - Raad H Mohiaddin
- />Cardiovascular Magnetic Resonance, Royal Brompton Hospital, Sydney Street, London, SW3 6NP UK
- />National Heart and Lung Institute, Imperial College London, London, UK
| | - David N Firmin
- />Cardiovascular Magnetic Resonance, Royal Brompton Hospital, Sydney Street, London, SW3 6NP UK
- />National Heart and Lung Institute, Imperial College London, London, UK
| |
Collapse
|
30
|
Abstract
4D flow MRI permits a comprehensive in-vivo assessment of three-directional blood flow within 3-dimensional vascular structures throughout the cardiac cycle. Given the large coverage permitted from a 4D flow acquisition, the distribution of vessel wall and flow parameters along an entire vessel of interest can thus be derived from a single measurement without being dependent on multiple predefined 2D acquisitions. In addition to qualitative 3D visualizations of complex cardiac and vascular flow patterns, quantitative flow analysis can be performed and is complemented by the ability to compute sophisticated hemodynamic parameters, such as wall shear stress or 3D pressure difference maps. These metrics can provide information previously unavailable with conventional modalities regarding the impact of cardiovascular disease or therapy on global and regional changes in hemodynamics. This review provides an introduction to the methodological aspects of 4D flow MRI to assess vascular hemodynamics and describes its potential for the assessment and understanding of altered hemodynamics in the presence of cardiovascular disease.
Collapse
|
31
|
Physiological Significance of Helical Flow in the Arterial System and its Potential Clinical Applications. Ann Biomed Eng 2014; 43:3-15. [DOI: 10.1007/s10439-014-1097-2] [Citation(s) in RCA: 93] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2014] [Accepted: 08/16/2014] [Indexed: 01/12/2023]
|
32
|
Stankovic Z, Allen BD, Garcia J, Jarvis KB, Markl M. 4D flow imaging with MRI. Cardiovasc Diagn Ther 2014; 4:173-92. [PMID: 24834414 DOI: 10.3978/j.issn.2223-3652.2014.01.02] [Citation(s) in RCA: 105] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2013] [Accepted: 10/21/2013] [Indexed: 12/22/2022]
Abstract
Magnetic resonance imaging (MRI) has become an important tool for the clinical evaluation of patients with cardiovascular disease. Since its introduction in the late 1980s, 2-dimensional phase contrast MRI (2D PC-MRI) has become a routine part of standard-of-care cardiac MRI for the assessment of regional blood flow in the heart and great vessels. More recently, time-resolved PC-MRI with velocity encoding along all three flow directions and three-dimensional (3D) anatomic coverage (also termed '4D flow MRI') has been developed and applied for the evaluation of cardiovascular hemodynamics in multiple regions of the human body. 4D flow MRI allows for the comprehensive evaluation of complex blood flow patterns by 3D blood flow visualization and flexible retrospective quantification of flow parameters. Recent technical developments, including the utilization of advanced parallel imaging techniques such as k-t GRAPPA, have resulted in reasonable overall scan times, e.g., 8-12 minutes for 4D flow MRI of the aorta and 10-20 minutes for whole heart coverage. As a result, the application of 4D flow MRI in a clinical setting has become more feasible, as documented by an increased number of recent reports on the utility of the technique for the assessment of cardiac and vascular hemodynamics in patient studies. A number of studies have demonstrated the potential of 4D flow MRI to provide an improved assessment of hemodynamics which might aid in the diagnosis and therapeutic management of cardiovascular diseases. The purpose of this review is to describe the methods used for 4D flow MRI acquisition, post-processing and data analysis. In addition, the article provides an overview of the clinical applications of 4D flow MRI and includes a review of applications in the heart, thoracic aorta and hepatic system.
Collapse
Affiliation(s)
- Zoran Stankovic
- 1 Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, USA ; 2 Department Biomedical Engineering, McCormick School of Engineering, Northwestern University, Chicago, USA
| | - Bradley D Allen
- 1 Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, USA ; 2 Department Biomedical Engineering, McCormick School of Engineering, Northwestern University, Chicago, USA
| | - Julio Garcia
- 1 Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, USA ; 2 Department Biomedical Engineering, McCormick School of Engineering, Northwestern University, Chicago, USA
| | - Kelly B Jarvis
- 1 Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, USA ; 2 Department Biomedical Engineering, McCormick School of Engineering, Northwestern University, Chicago, USA
| | - Michael Markl
- 1 Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, USA ; 2 Department Biomedical Engineering, McCormick School of Engineering, Northwestern University, Chicago, USA
| |
Collapse
|
33
|
Kadbi M, Negahdar M, Traughber M, Martin P, Amini AA. Assessment of flow and hemodynamics in the carotid artery using a reduced TE 4D flow spiral phase-contrast MRI. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2014; 2013:1100-3. [PMID: 24109884 DOI: 10.1109/embc.2013.6609697] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
4D flow MRI is a powerful technique for quantitative flow assessment and visualization of complex flow patterns and hemodynamics of cardiovascular flows. This technique results in more anatomical information and comprehensive assessment of blood flow. However, conventional 4D PC MRI suffers from a few obstacles for clinical applications. The total scan time is long, especially in large volumes with high spatial resolutions. Inaccuracy of conventional Cartesian PC MRI in the setting of atherosclerosis and in general, disturbed and turbulent blood flow is another important challenge. This inaccuracy is the consequence of signal loss, intravoxel dephasing and flow-related artifact in the presence of disturbed and turbulent flow. Spiral k-space trajectory has valuable attributes which can help overcome some of the problems with 4D flow Cartesian acquisitions. Spiral trajectory benefits from shorter TE and reduces the flow-related artifacts. In addition, short spiral readouts with spiral interleaves can significantly reduce the total scan time, reducing the chances of patient motion which may also corrupt the data in the form of motion artifacts. In this paper, the accuracy of flow assessment and flow visualization with reduced TE 4D Spiral PC was investigated and good agreement was observed between the spiral and conventional technique. The systolic mean velocity, peak flow and the average flow in CCA and ICA of normal volunteers using 4D spiral PC MRI showed errors less than 10% compared to conventional 4D PC MRI. In addition, the scan time using spiral sequence was 3∶31 min which is half of the time using conventional sequence.
Collapse
|
34
|
Kadbi M, Negahdar M, Cha JW, Traughber M, Martin P, Stoddard MF, Amini AA. 4D UTE flow: a phase-contrast MRI technique for assessment and visualization of stenotic flows. Magn Reson Med 2014; 73:939-50. [PMID: 24604617 DOI: 10.1002/mrm.25188] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2013] [Revised: 01/22/2014] [Accepted: 02/02/2014] [Indexed: 11/10/2022]
Abstract
PURPOSE Inaccuracy of conventional four-dimensional (4D) flow MR imaging in the presence of random unsteady and turbulent blood flow distal to a narrowing has been an important challenge. Previous investigations have revealed that shorter echo times (TE) decrease the errors, leading to more accurate flow assessments. METHODS In this study, as part of a 4D flow acquisition, an Ultra-Short TE (UTE) method was adopted. UTE works based on a center-out radial k-space trajectory that inherently has a short TE. By employing free induction decay sampling starting from read-out gradient ramp-up, and by combining the refocusing lobe of the slice select gradient with the bipolar flow encoding gradient, TEs of ≈1 msec may be achieved. RESULTS Both steady and pulsatile flow regimes, and in each case a range of Reynolds numbers, were studied in an in-vitro model. Flow assessment at low and medium flow rates demonstrated a good agreement between 4D UTE and conventional 4D flow techniques. However, 4D UTE flow significantly outperformed conventional 4D flow, at high flow rates for both steady and pulsatile flow regimes. Feasibility of the method in one patient with Aortic Stenosis was also demonstrated. CONCLUSION For both steady and pulsatile high flow rates, the measured flow distal to the stenotic narrowing using conventional 4D flow revealed more than 20% error compared to the ground-truth flow. This error was reduced to less than 5% using the 4D UTE flow technique.
Collapse
Affiliation(s)
- Mo Kadbi
- Electrical and Computer Engineering Department, University of Louisville, Louisville, Kentucky, USA
| | | | | | | | | | | | | |
Collapse
|
35
|
Rodriguez Muñoz D, Markl M, Moya Mur JL, Barker A, Fernández-Golfín C, Lancellotti P, Zamorano Gómez JL. Intracardiac flow visualization: current status and future directions. Eur Heart J Cardiovasc Imaging 2013; 14:1029-38. [PMID: 23907342 DOI: 10.1093/ehjci/jet086] [Citation(s) in RCA: 84] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Non-invasive cardiovascular imaging initially focused on heart structures, allowing the visualization of their motion and inferring its functional status from it. Colour-Doppler and cardiac magnetic resonance (CMR) have allowed a visual approach to intracardiac flow behaviour, as well as measuring its velocity at single selected spots. Recently, the application of new technologies to medical use and, particularly, to cardiology has allowed, through different algorithms in CMR and applications of ultrasound-related techniques, the description and analysis of flow behaviour in all points and directions of the selected region, creating the opportunity to incorporate new data reflecting cardiac performance to cardiovascular imaging. The following review provides an overview of the currently available imaging techniques that enable flow visualization, as well as its present and future applications based on the available literature and on-going works.
Collapse
Affiliation(s)
- Daniel Rodriguez Muñoz
- Department of Cardiology, Ramón y Cajal University Hospital, Ctra. de Colmenar, Km 9, 100, PO 28031 Madrid, Spain
| | | | | | | | | | | | | |
Collapse
|
36
|
Abstract
Traditionally, magnetic resonance imaging (MRI) of flow using phase contrast (PC) methods is accomplished using methods that resolve single-directional flow in two spatial dimensions (2D) of an individual slice. More recently, three-dimensional (3D) spatial encoding combined with three-directional velocity-encoded phase contrast MRI (here termed 4D flow MRI) has drawn increased attention. 4D flow MRI offers the ability to measure and to visualize the temporal evolution of complex blood flow patterns within an acquired 3D volume. Various methodological improvements permit the acquisition of 4D flow MRI data encompassing individual vascular structures and entire vascular territories such as the heart, the adjacent aorta, the carotid arteries, abdominal, or peripheral vessels within reasonable scan times. To subsequently analyze the flow data by quantitative means and visualization of complex, three-directional blood flow patterns, various tools have been proposed. This review intends to introduce currently used 4D flow MRI methods, including Cartesian and radial data acquisition, approaches for accelerated data acquisition, cardiac gating, and respiration control. Based on these developments, an overview is provided over the potential this new imaging technique has in different parts of the body from the head to the peripheral arteries.
Collapse
Affiliation(s)
- Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois 60611, USA.
| | | | | | | | | |
Collapse
|
37
|
Strecker C, Harloff A, Wallis W, Markl M. Flow-sensitive 4D MRI of the thoracic aorta: Comparison of image quality, quantitative flow, and wall parameters at 1.5 T and 3 T. J Magn Reson Imaging 2012; 36:1097-103. [DOI: 10.1002/jmri.23735] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2011] [Accepted: 05/17/2012] [Indexed: 11/09/2022] Open
|
38
|
Magnetic resonance velocity mapping of 3D cerebrospinal fluid flow dynamics in hydrocephalus: preliminary results. Eur Radiol 2011; 22:232-42. [DOI: 10.1007/s00330-011-2247-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2011] [Revised: 06/21/2011] [Accepted: 07/08/2011] [Indexed: 10/17/2022]
|
39
|
Morita S, Masukawa A, Suzuki K, Hirata M, Kojima S, Ueno E. Unenhanced MR Angiography: Techniques and Clinical Applications in Patients with Chronic Kidney Disease. Radiographics 2011; 31:E13-33. [DOI: 10.1148/rg.312105075] [Citation(s) in RCA: 80] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
40
|
Markl M, Kilner PJ, Ebbers T. Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2011; 13:7. [PMID: 21235751 PMCID: PMC3025879 DOI: 10.1186/1532-429x-13-7] [Citation(s) in RCA: 290] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2010] [Accepted: 01/14/2011] [Indexed: 01/20/2023] Open
Abstract
BACKGROUND Phase contrast cardiovascular magnetic resonance (CMR) is able to measure all three directional components of the velocities of blood flow relative to the three spatial dimensions and the time course of the heart cycle. In this article, methods used for the acquisition, visualization, and quantification of such datasets are reviewed and illustrated. METHODS Currently, the acquisition of 3D cine (4D) phase contrast velocity data, synchronized relative to both cardiac and respiratory movements takes about ten minutes or more, even when using parallel imaging and optimized pulse sequence design. The large resulting datasets need appropriate post processing for the visualization of multidirectional flow, for example as vector fields, pathlines or streamlines, or for retrospective volumetric quantification. APPLICATIONS Multidirectional velocity acquisitions have provided 3D visualization of large scale flow features of the healthy heart and great vessels, and have shown altered patterns of flow in abnormal chambers and vessels. Clinically relevant examples include retrograde streams in atheromatous descending aortas as potential thrombo-embolic pathways in patients with cryptogenic stroke and marked variations of flow visualized in common aortic pathologies. Compared to standard clinical tools, 4D velocity mapping offers the potential for retrospective quantification of flow and other hemodynamic parameters. CONCLUSIONS Multidirectional, 3D cine velocity acquisitions are contributing to the understanding of normal and pathologically altered blood flow features. Although more rapid and user-friendly strategies for acquisition and analysis may be needed before 4D velocity acquisitions come to be adopted in routine clinical CMR, their capacity to measure multidirectional flows throughout a study volume has contributed novel insights into cardiovascular fluid dynamics in health and disease.
Collapse
Affiliation(s)
- Michael Markl
- Department of Radiology, Medical Physics, University Hospital Freiburg, Germany
| | - Philip J Kilner
- CMR Unit, Royal Brompton Hospital and Imperial College, London, UK
| | - Tino Ebbers
- Center for Medical Image Science and Visualization, Linköping University, Sweden
| |
Collapse
|
41
|
Winterer JT, Blanke P, Schaefer A, Pache G, Langer M, Markl M. Bilateral contrast-enhanced MR angiography of the hand: diagnostic image quality of accelerated MRI using echo sharing with interleaved stochastic trajectories (TWIST). Eur Radiol 2010; 21:1026-33. [PMID: 21085967 DOI: 10.1007/s00330-010-2002-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2010] [Revised: 09/10/2010] [Accepted: 09/15/2010] [Indexed: 11/25/2022]
Abstract
OBJECTIVES To evaluate the image quality of time-resolved contrast-enhanced MRA (tr-MRA) employing echo-sharing with stochastic trajectories for the bilateral examination of the hands. METHODS In this institutional review-board approved study, Tr-MRA was compared with multiphasic contrast-enhanced MRA (mp-MRA) featuring sub-systolic venous compression in 20 healthy volunteers at 3.0 T using the following settings: TR/TE: 2.8/1.2 ms, flip angle: 25°, acceleration factor: 4, effective voxel size: 0.9 × 0.8 × 0.9 cm, acquisition time 4.9 s per 3D volume. RESULTS With tr-MRA the arterial first-pass contrast agent transit is clearly seen. On average the contrast agent arrived 34 s post-injection and reached the proper digital arteries after 44 s. The mean arterio-venous window was 13 s. Bilateral contrast enhancement was asynchronous in 56-62%. On a semiquantitative scale (0 = non-sufficient to 4 = excellent) tr-MRA (mp-MRA) yielded an average ranking of 2.8-3.6 (3.1-3.8) in the greater and intermediate sized segments and 1.3-2.0 (1.6-2.3) in the proper digital arteries. CONCLUSION Compared with established multiphasic ce-MRA, time-resolved MRA allows a four times faster acquisition. It reflects the natural haemodynamics of the hand arteries with no need for sub-systolic venous compression and may be beneficial in the detection of hand circulation disorders. Image quality is comparable to mp-MRA. In both techniques depiction of the proper digital arteries is limited.
Collapse
Affiliation(s)
- Jan Thorsten Winterer
- Department of Radiology, University Hospital of Freiburg, Hugstetter Str 55, D-79106 Freiburg, Germany.
| | | | | | | | | | | |
Collapse
|
42
|
Schwarz M, Krueger MW, Busch HJ, Benk C, Heilmann C. Model-based assessment of tissue perfusion and temperature in deep hypothermic patients. IEEE Trans Biomed Eng 2010; 57:1577-86. [PMID: 20442040 DOI: 10.1109/tbme.2010.2048324] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Deep hypothermic circulatory arrest is necessary for some types of cardiac and aortic surgery. Perfusion of the brain can be maintained using a heart-lung machine and unilateral antegrade cerebral perfusion. Cooling rates during extracorporeal circulation depend on local perfusion. A core temperature of 24 degrees C-25 degrees C is aimed at to extend ischemic tolerance of tissues. Information on cerebral perfusion and temperature is important for the safety of patients, but hardly accessible to measurement. A combined simulation model of hemodynamics and temperature is presented in this paper. The hemodynamics model employs the transmission-line approach and integrates the Circle of Willis (CoW). This allows for parameterization of individual aberrations. Simulation results of cerebral perfusion are shown for two configurations of the CoW. The temperature model provides spatial information on temperature fields. It considers heat transfer in the various tissues retrieving data of local tissue perfusion from the hemodynamics model. The combined model is evaluated by retrospective simulation of two aortic operations.
Collapse
|
43
|
Stadlbauer A, Salomonowitz E, van der Riet W, Buchfelder M, Ganslandt O. Insight into the patterns of cerebrospinal fluid flow in the human ventricular system using MR velocity mapping. Neuroimage 2010; 51:42-52. [DOI: 10.1016/j.neuroimage.2010.01.110] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2009] [Revised: 01/25/2010] [Accepted: 01/29/2010] [Indexed: 10/19/2022] Open
|
44
|
den Reijer PM, Sallee D, van der Velden P, Zaaijer ER, Parks WJ, Ramamurthy S, Robbie TQ, Donati G, Lamphier C, Beekman RP, Brummer ME. Hemodynamic predictors of aortic dilatation in bicuspid aortic valve by velocity-encoded cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2010; 12:4. [PMID: 20070904 PMCID: PMC2827385 DOI: 10.1186/1532-429x-12-4] [Citation(s) in RCA: 93] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2009] [Accepted: 01/13/2010] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND Congenital bicuspid aortic valve (BAV) is a significant risk factor for serious complications including valve dysfunction, aortic dilatation, dissection, and sudden death. Clinical tools for identification and monitoring of BAV patients at high risk for development of aortic dilatation, an early complication, are not available. METHODS This paper reports an investigation in 18 pediatric BAV patients and 10 normal controls of links between abnormal blood flow patterns in the ascending aorta and aortic dilatation using velocity-encoded cardiovascular magnetic resonance. Blood flow patterns were quantitatively expressed in the angle between systolic left ventricular outflow and the aortic root channel axis, and also correlated with known biochemical markers of vessel wall disease. RESULTS The data confirm larger ascending aortas in BAV patients than in controls, and show more angled LV outflow in BAV (17.54 +/- 0.87 degrees) than controls (10.01 +/- 1.29) (p = 0.01). Significant correlation of systolic LV outflow jet angles with dilatation was found at different levels of the aorta in BAV patients STJ: r = 0.386 (N = 18, p = 0.048), AAO: r = 0.536 (N = 18, p = 0.022), and stronger correlation was found with patients and controls combined into one population: SOV: r = 0.405 (N = 28, p = 0.033), STJ: r = 0.562 (N = 28, p = 0.002), and AAO r = 0.645 (N = 28, p < 0.001). Dilatation and the flow jet angle were also found to correlate with plasma levels of matrix metallo-proteinase 2. CONCLUSIONS The results of this study provide new insights into the pathophysiological processes underlying aortic dilatation in BAV patients. These results show a possible path towards the development of clinical risk stratification protocols in order to reduce morbidity and mortality for this common congenital heart defect.
Collapse
Affiliation(s)
- P Martijn den Reijer
- Leiden University Medical Center, Leiden, The Netherlands
- Emory University School of Medicine, Atlanta, Georgia, USA
| | - Denver Sallee
- Sibley Heart Center Cardiology, Atlanta, Georgia, USA
- Emory University School of Medicine, Atlanta, Georgia, USA
| | | | | | - W James Parks
- Sibley Heart Center Cardiology, Atlanta, Georgia, USA
- Emory University School of Medicine, Atlanta, Georgia, USA
| | | | | | | | - Carey Lamphier
- Emory University School of Medicine, Atlanta, Georgia, USA
| | | | | |
Collapse
|
45
|
Santini F, Wetzel SG, Bock J, Markl M, Scheffler K. Time-resolved three-dimensional (3D) phase-contrast (PC) balanced steady-state free precession (bSSFP). Magn Reson Med 2010; 62:966-74. [PMID: 19585606 DOI: 10.1002/mrm.22087] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
In this study the feasibility of a time-resolved, three-dimensional (3D), three-directional flow-sensitive balanced steady-state free precession (bSSFP) sequence is demonstrated. Due to its high signal-to-noise ratio (SNR) in blood and cerebrospinal fluid (CSF) this type of sequence is particularly effective for acquisition of blood and CSF flow velocities. Flow sensitivity was achieved with the phase-contrast (PC) technique, implementing a custom algorithm for calculation of optimal gradient parameters. Techniques to avoid the most important sources of bSSFP-related artifacts (including distortion due to eddy currents and signal voids due to flow-related steady-state disruption) are also presented. The technique was validated by means of a custom flow phantom, and in vivo experiments on blood and CSF were performed to demonstrate the suitability of this sequence for human studies. Accurate depiction of blood flow in the cerebral veins and of CSF flow in the cervical portion of the neck was obtained. Possible applications of this technique might include the study of CSF flow patterns, direct in vivo study of pathologies such as hydrocephalus and Chiari malformation, and validation for the existing CSF circulation model.
Collapse
Affiliation(s)
- Francesco Santini
- Department of Radiological Physics, Institute of Radiology, University of Basel Hospital, Basel, Switzerland.
| | | | | | | | | |
Collapse
|
46
|
Stadlbauer A, van der Riet W, Crelier G, Salomonowitz E. Accelerated time-resolved three-dimensional MR velocity mapping of blood flow patterns in the aorta using SENSE and k-t BLAST. Eur J Radiol 2009; 75:e15-21. [PMID: 19581063 DOI: 10.1016/j.ejrad.2009.06.009] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2009] [Revised: 05/13/2009] [Accepted: 06/08/2009] [Indexed: 12/21/2022]
Abstract
PURPOSE To assess the feasibility and potential limitations of the acceleration techniques SENSE and k-t BLAST for time-resolved three-dimensional (3D) velocity mapping of aortic blood flow. Furthermore, to quantify differences in peak velocity versus heart phase curves. MATERIALS AND METHODS Time-resolved 3D blood flow patterns were investigated in eleven volunteers and two patients suffering from aortic diseases with accelerated PC-MR sequences either in combination with SENSE (R=2) or k-t BLAST (6-fold). Both sequences showed similar data acquisition times and hence acceleration efficiency. Flow-field streamlines were calculated and visualized using the GTFlow software tool in order to reconstruct 3D aortic blood flow patterns. Differences between the peak velocities from single-slice PC-MRI experiments using SENSE 2 and k-t BLAST 6 were calculated for the whole cardiac cycle and averaged for all volunteers. RESULTS Reconstruction of 3D flow patterns in volunteers revealed attenuations in blood flow dynamics for k-t BLAST 6 compared to SENSE 2 in terms of 3D streamlines showing fewer and less distinct vortices and reduction in peak velocity, which is caused by temporal blurring. Solely by time-resolved 3D MR velocity mapping in combination with SENSE detected pathologic blood flow patterns in patients with aortic diseases. For volunteers, we found a broadening and flattering of the peak velocity versus heart phase diagram between the two acceleration techniques, which is an evidence for the temporal blurring of the k-t BLAST approach. CONCLUSION We demonstrated the feasibility of SENSE and detected potential limitations of k-t BLAST when used for time-resolved 3D velocity mapping. The effects of higher k-t BLAST acceleration factors have to be considered for application in 3D velocity mapping.
Collapse
Affiliation(s)
- Andreas Stadlbauer
- MR Physics Group, Department of Radiology, Landesklinikum St. Poelten, Propst Fuehrer Strasse 4, 3100 St. Poelten, Austria.
| | | | | | | |
Collapse
|
47
|
Bloch KM, Carlsson M, Arheden H, Ståhlberg F. Quantifying coronary sinus flow and global LV perfusion at 3T. BMC Med Imaging 2009; 9:9. [PMID: 19519892 PMCID: PMC2702273 DOI: 10.1186/1471-2342-9-9] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2008] [Accepted: 06/11/2009] [Indexed: 11/30/2022] Open
Abstract
Background Despite the large availability of 3T MR scanners and the potential of high field imaging, this technical platform has yet to prove its usefulness in the cardiac MR setting, where 1.5T remains the established standard. Global perfusion of the left ventricle, as well as the coronary flow reserve (CFR), can provide relevant diagnostic information, and MR measurements of these parameters may benefit from increased field strength. Quantitative flow measurements in the coronary sinus (CS) provide one method to investigate these parameters. However, the ability of newly developed faster MR sequences to measure coronary flow during a breath-hold at 3T has not been evaluated. Methods The aim of this work was to measure CS flow using segmented phase contrast MR (PC MR) on a clinical 3T MR scanner. Parallel imaging was employed to reduce the total acquisition time. Global LV perfusion was calculated by dividing CS flow with left ventricular (LV) mass. The repeatability of the method was investigated by measuring the flow three times in each of the twelve volunteers. Phantom experiments were performed to investigate potential error sources. Results The average CS flow was determined to 88 ± 33 ml/min and the deduced LV perfusion was 0.60 ± 0.22 ml/min·g, in agreement with published values. The repeatability (1-error) of the three repeated measurements in each subject was on average 84%. Conclusion This work demonstrates that the combination of high field strength (3T), parallel imaging and segmented gradient echo sequences allow for quantification of the CS flow and global perfusion within a breath-hold.
Collapse
|
48
|
Harloff A, Albrecht F, Spreer J, Stalder AF, Bock J, Frydrychowicz A, Schöllhorn J, Hetzel A, Schumacher M, Hennig J, Markl M. 3D blood flow characteristics in the carotid artery bifurcation assessed by flow-sensitive 4D MRI at 3T. Magn Reson Med 2009; 61:65-74. [PMID: 19097219 DOI: 10.1002/mrm.21774] [Citation(s) in RCA: 103] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
To determine three-dimensional (3D) blood flow patterns in the carotid bifurcation, 10 healthy volunteers and nine patients with internal carotid artery (ICA) stenosis > or =50% were examined by flow-sensitive 4D MRI at 3T. Absolute and mean blood velocities, pulsatility index (PI), and resistance index (RI) were measured in the common carotid arteries (CCAs) by duplex sonography (DS) and compared with flow-sensitive 4D MRI. Furthermore, 3D MRI blood flow patterns in the carotid bifurcation of volunteers and patients before and after recanalization were graded by two independent readers. Blood flow velocities measured by MRI were 31-39% lower than in DS. However, PI and RI differed by only 13-16%. Rating of 3D flow characteristics in the ICA revealed consistent patterns for filling and helical flow in volunteers. In patients with ICA stenosis, 3D blood flow visualization was successfully employed to detect markedly altered filling and helical flow patterns (forward-moving spiral flow) in the ICA bulb and to evaluate the effect of revascularization, which restored filling and helical flow. Our results demonstrate the feasibility of flow-sensitive 4D MRI for the quantification and 3D visualization of physiological and pathological flow patterns in the carotid artery bifurcation.
Collapse
Affiliation(s)
- A Harloff
- Department of Neurology and Clinical Neurophysiology, University of Freiburg, Freiburg, Germany.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
49
|
Brix L, Ringgaard S, Rasmusson A, Sørensen TS, Kim WY. Three dimensional three component whole heart cardiovascular magnetic resonance velocity mapping: comparison of flow measurements from 3D and 2D acquisitions. J Cardiovasc Magn Reson 2009; 11:3. [PMID: 19232119 PMCID: PMC2649114 DOI: 10.1186/1532-429x-11-3] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2008] [Accepted: 02/20/2009] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Two-dimensional, unidirectionally encoded, cardiovascular magnetic resonance (CMR) velocity mapping is an established technique for the quantification of blood flow in large vessels. However, it requires an operator to correctly align the planes of acquisition. If all three directional components of velocity are measured for each voxel of a 3D volume through the phases of the cardiac cycle, blood flow through any chosen plane can potentially be calculated retrospectively. The initial acquisition is then more time consuming but relatively operator independent. AIMS To compare the curves and volumes of flow derived from conventional 2D and comprehensive 3D flow acquisitions in a steady state flow model, and in vivo through planes transecting the ascending aorta and pulmonary trunk in 10 healthy volunteers. METHODS Using a 1.5 T Phillips Intera CMR system, 3D acquisitions used an anisotropic 3D segmented k-space phase contrast gradient echo sequence with a short EPI readout, with prospective ECG and diaphragm navigator gating. The 2D acquisitions used segmented k-space phase contrast with prospective ECG and diaphragm navigator gating. Quantitative flow analyses were performed retrospectively with dedicated software for both the in vivo and in vitro acquisitions. RESULTS Analysis of in vitro data found the 3D technique to have overestimated the continuous flow rate by approximately 5% across the entire applied flow range. In vivo, the 2D and the 3D techniques yielded similar volumetric flow curves and measurements. Aortic flow: (mean +/- SD), 2D = 89.5 +/- 13.5 ml & 3D = 92.7 +/- 17.5 ml. Pulmonary flow: 2D = 98.8 +/- 18.4 ml & 3D = 94.9 +/- 19.0 ml). Each in vivo 3D acquisition took about 8 minutes or more. CONCLUSION Flow measurements derived from the 3D and 2D acquisitions were comparable. Although time consuming, comprehensive 3D velocity acquisition could be relatively operator independent, and could potentially yield information on flow through several retrospectively chosen planes, for example in patients with congenital or valvular heart disease.
Collapse
Affiliation(s)
- Lau Brix
- Department of Biomedical Engineering, Region Midtjylland, c/o Aarhus University Hospital, Skejby, Denmark
- MR-Centre, Aarhus University Hospital, Skejby, Denmark
| | | | - Allan Rasmusson
- Department of Computer Science, University of Aarhus, Aarhus, Denmark
| | - Thomas Sangild Sørensen
- Department of Computer Science, University of Aarhus, Aarhus, Denmark
- Institute of Clinical Medicine, University of Aarhus, Aarhus, Denmark
| | - W Yong Kim
- MR-Centre, Aarhus University Hospital, Skejby, Denmark
- Department of Cardiology, Aarhus University Hospital, Skejby, Denmark
| |
Collapse
|
50
|
Markl M, Benk C, Klausmann D, Stalder AF, Frydrychowicz A, Hennig J, Beyersdorf F. Three-dimensional magnetic resonance flow analysis in a ventricular assist device. J Thorac Cardiovasc Surg 2007; 134:1471-6. [PMID: 18023667 DOI: 10.1016/j.jtcvs.2007.05.024] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2007] [Revised: 04/13/2007] [Accepted: 05/02/2007] [Indexed: 10/22/2022]
Abstract
OBJECTIVE The assessment of flow characteristics inside ventricular assist devices by magnetic resonance imaging techniques may provide insight into the mechanisms underlying the high rate of thromboembolic events after implantation of a ventricular assist device. Furthermore, these investigations may form the basis to optimize the device's design and its need for anticoagulation. The purpose of this study was to integrate a clinical routine ventricular assist device into a flow circuit with realistic geometric and pulsatile inflow conditions. Combination with flow-sensitive magnetic resonance imaging at 3 T permitted the detailed analysis of local and global 3-dimensional flow dynamics in a realistic environment. METHODS A commercially available ventricular assist device was integrated into a magnetic resonance-compatible flow circuit. Flow-sensitive 3-dimensional magnetic resonance imaging was performed to measure time-resolved 3-directional flow velocities in the entire device. Advanced computer-aided 3-dimensional flow visualization methods were used to derive a comprehensive picture of flow dynamics within the ventricular assist device system. RESULTS On the basis of the ventricular assist device model system, magnetic resonance imaging, and flow visualization, the first 4-dimensional functional magnetic resonance imaging analysis of flow characteristics inside an operating clinical routine ventricular assist device chamber system is reported. Detailed visualization of flow patterns and local changes in flow characteristics were successfully performed and revealed locally accelerated, vortical, and helical flow regions inside the geometry of the device. CONCLUSIONS Complex flow patterns such as vortex formation and locally accelerated flow demonstrate the potential of the presented method to further deepen the understanding of complex and regionally different flow characteristics inside ventricular assist devices.
Collapse
Affiliation(s)
- Michael Markl
- Department of Diagnostic Radiology, Medical Physics, University Hospital Freiburg, Germany
| | | | | | | | | | | | | |
Collapse
|