Rama E, Mohapatra SR, Sugimura Y, Suzuki T, Siebert S, Barmin R, Hermann J, Baier J, Rix A, Lemainque T, Koletnik S, Elshafei AS, Pallares RM, Dadfar SM, Tolba RH, Schulz V, Jankowski J, Apel C, Akhyari P, Jockenhoevel S, Kiessling F. In vitro and in vivo evaluation of biohybrid tissue-engineered vascular grafts with transformative 1H/ 19F MRI traceable scaffolds. Biomaterials 2024; 311:122669. [PMID: 38906013 DOI: 10.1016/j.biomaterials.2024.122669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 06/09/2024] [Accepted: 06/14/2024] [Indexed: 06/23/2024]
Abstract
Biohybrid tissue-engineered vascular grafts (TEVGs) promise long-term durability due to their ability to adapt to hosts' needs. However, the latter calls for sensitive non-invasive imaging approaches to longitudinally monitor their functionality, integrity, and positioning. Here, we present an imaging approach comprising the labeling of non-degradable and degradable TEVGs' components for their in vitro and in vivo monitoring by hybrid 1H/19F MRI. TEVGs (inner diameter 1.5 mm) consisted of biodegradable poly(lactic-co-glycolic acid) (PLGA) fibers passively incorporating superparamagnetic iron oxide nanoparticles (SPIONs), non-degradable polyvinylidene fluoride scaffolds labeled with highly fluorinated thermoplastic polyurethane (19F-TPU) fibers, a smooth muscle cells containing fibrin blend, and endothelial cells. 1H/19F MRI of TEVGs in bioreactors, and after subcutaneous and infrarenal implantation in rats, revealed that PLGA degradation could be faithfully monitored by the decreasing SPIONs signal. The 19F signal of 19F-TPU remained constant over weeks. PLGA degradation was compensated by cells' collagen and α-smooth-muscle-actin deposition. Interestingly, only TEVGs implanted on the abdominal aorta contained elastin. XTT and histology proved that our imaging markers did not influence extracellular matrix deposition and host immune reaction. This concept of non-invasive longitudinal assessment of cardiovascular implants using 1H/19F MRI might be applicable to various biohybrid tissue-engineered implants, facilitating their clinical translation.
Collapse
Affiliation(s)
- Elena Rama
- Institute for Experimental Molecular Imaging, Faculty of Medicine, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
| | - Saurav Ranjan Mohapatra
- Department of Biohybrid & Medical Textiles, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
| | - Yukiharu Sugimura
- Department of Cardiac Surgery, Medical Faculty and RWTH University Hospital Aachen, RWTH Aachen University, Aachen, Germany
| | - Tomoyuki Suzuki
- Department of Cardiac Surgery, Medical Faculty and RWTH University Hospital Aachen, RWTH Aachen University, Aachen, Germany
| | - Stefan Siebert
- Department of Biohybrid & Medical Textiles, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
| | - Roman Barmin
- Institute for Experimental Molecular Imaging, Faculty of Medicine, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
| | - Juliane Hermann
- Institute for Molecular Cardiovascular Research (IMCAR), University Hospital RWTH Aachen, Aachen, Germany
| | - Jasmin Baier
- Institute for Experimental Molecular Imaging, Faculty of Medicine, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
| | - Anne Rix
- Institute for Experimental Molecular Imaging, Faculty of Medicine, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
| | - Teresa Lemainque
- Institute for Experimental Molecular Imaging, Faculty of Medicine, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany; Department of Diagnostic and Interventional Radiology, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Susanne Koletnik
- Institute for Experimental Molecular Imaging, Faculty of Medicine, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
| | - Asmaa Said Elshafei
- Institute for Experimental Molecular Imaging, Faculty of Medicine, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
| | - Roger Molto Pallares
- Institute for Experimental Molecular Imaging, Faculty of Medicine, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
| | - Seyed Mohammadali Dadfar
- Institute for Experimental Molecular Imaging, Faculty of Medicine, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany; Ardena Oss, 5349 AB Oss, the Netherlands
| | - René H Tolba
- Institute for Laboratory Animal Science and Experimental Surgery, Medical Faculty, RWTH Aachen International University, Aachen, Germany
| | - Volkmar Schulz
- Institute for Experimental Molecular Imaging, Faculty of Medicine, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
| | - Joachim Jankowski
- Institute for Molecular Cardiovascular Research (IMCAR), University Hospital RWTH Aachen, Aachen, Germany; Aachen-Maastricht Institute for CardioRenal Disease (AMICARE), University Hospital RWTH Aachen, Aachen, Germany; Department of Pathology, Cardiovascular Research Institute Maastricht (CARIM), University of Maastricht, the Netherlands
| | - Christian Apel
- Department of Biohybrid & Medical Textiles, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
| | - Payam Akhyari
- Department of Cardiac Surgery, Medical Faculty and RWTH University Hospital Aachen, RWTH Aachen University, Aachen, Germany
| | - Stefan Jockenhoevel
- Department of Biohybrid & Medical Textiles, AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
| | - Fabian Kiessling
- Institute for Experimental Molecular Imaging, Faculty of Medicine, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany.
| |
Collapse
|
2
|
Maxouri O, Bodalal Z, Daal M, Rostami S, Rodriguez I, Akkari L, Srinivas M, Bernards R, Beets-Tan R. How to 19F MRI: applications, technique, and getting started. BJR Open 2023; 5:20230019. [PMID: 37953866 PMCID: PMC10636348 DOI: 10.1259/bjro.20230019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 07/26/2023] [Accepted: 08/01/2023] [Indexed: 11/14/2023] Open
Abstract
Magnetic resonance imaging (MRI) plays a significant role in the routine imaging workflow, providing both anatomical and functional information. 19F MRI is an evolving imaging modality where instead of 1H, 19F nuclei are excited. As the signal from endogenous 19F in the body is negligible, exogenous 19F signals obtained by 19F radiofrequency coils are exceptionally specific. Highly fluorinated agents targeting particular biological processes (i.e., the presence of immune cells) have been visualised using 19F MRI, highlighting its potential for non-invasive and longitudinal molecular imaging. This article aims to provide both a broad overview of the various applications of 19F MRI, with cancer imaging as a focus, as well as a practical guide to 19F imaging. We will discuss the essential elements of a 19F system and address common pitfalls during acquisition. Last but not least, we will highlight future perspectives that will enhance the role of this modality. While not an exhaustive exploration of all 19F literature, we endeavour to encapsulate the broad themes of the field and introduce the world of 19F molecular imaging to newcomers. 19F MRI bridges several domains, imaging, physics, chemistry, and biology, necessitating multidisciplinary teams to be able to harness this technology effectively. As further technical developments allow for greater sensitivity, we envision that 19F MRI can help unlock insight into biological processes non-invasively and longitudinally.
Collapse
Affiliation(s)
| | | | | | | | | | - Leila Akkari
- Division of Tumor Biology and Immunology, Oncode Institute, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | | | - René Bernards
- Division of Molecular Carcinogenesis, Oncode Institute, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | | |
Collapse
|
3
|
Özen AC, Spreter F, Schimpf W, Fischer J, Ilbey S, Reiss S, Maier A, von Elverfeldt D, Heidt T, von Zur Mühlen C, Bock M. Scalable and modular 8-channel transmit and 8-channel flexible receive coil array for 19 F MRI of large animals. Magn Reson Med 2023; 89:1237-1250. [PMID: 36226654 DOI: 10.1002/mrm.29490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 09/23/2022] [Accepted: 09/24/2022] [Indexed: 02/02/2023]
Abstract
PURPOSE To introduce an RF coil system consisting of an 8-channel transmit (Tx) and 8-channel receive (Rx) coil arrays for 19 F MRI of large animals. METHODS The Tx efficiency and homogeneity of the 8-element loop coil array (loop size: 6 × 15 cm2 ) were simulated for two different pig models rendered from MR images. An 8-channel Rx coil array consisting of a flexible 6-channel posterior and a 2-channel planar anterior array was designed to fit on the abdomen of an average-sized pig in supine position. Measurements were performed in a grid phantom and ex vivo on a pig model with perfluoroctylbromide (PFOB)-filled tubes inserted in the thorax. RESULTS Measured and simulated Tx efficiency and homogeneity for the 8-channel and 5-channel arrays were in good agreement: 1.87 ± 0.22μT/√kW versus 1.96 ± 0.29μT/√kW, and 2.29 ± 0.39μT/√kW versus 2.41 ± 0.37μT/√kW. An isolation of 38 ± 8 dB is achieved between the 19 F Tx and Rx elements, and over 30 dB between the 1 H and 19 F elements. The PFOB-filled vials could be clearly identified within the cadaver abdomen with an SNR of 275 ± 51 for a 3D gradient-echo sequence with 2-mm isotropic resolution and 12 averages, acquired in 9:52 min:s. Performance of the Tx array was robust against phase and amplitude mismatches at the input ports. CONCLUSIONS A modular and scalable Tx array offers improved Tx efficiency in 19 F MRI of large animals with various sizes. Although conventional birdcage coils have superior Tx efficiency within the target region of interest, scalability of the Tx array to animal size is a major benefit. The described 19 F coil provides homogeneous excitation and high sensitivity detection in large pig models.
Collapse
Affiliation(s)
- Ali Caglar Özen
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Felix Spreter
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Waldemar Schimpf
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Johannes Fischer
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Serhat Ilbey
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Simon Reiss
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Alexander Maier
- Department of Cardiology and Angiology I, University Heart Center, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Dominik von Elverfeldt
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Timo Heidt
- Department of Cardiology and Angiology I, University Heart Center, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Constantin von Zur Mühlen
- Department of Cardiology and Angiology I, University Heart Center, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Michael Bock
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| |
Collapse
|
4
|
Untuned broadband spiral micro-coils achieve sensitive multi-nuclear NMR TX/RX from microfluidic samples. Sci Rep 2021; 11:7798. [PMID: 33833324 PMCID: PMC8032710 DOI: 10.1038/s41598-021-87247-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 03/22/2021] [Indexed: 11/17/2022] Open
Abstract
The low frequency plateau in the frequency response of an untuned micro-resonator permits broadband radio-frequency reception, albeit at the expense of optimal signal-to-noise ratio for a particular nucleus. In this contribution we determine useful figures of merit for broadband micro-coils, and thereby explore the parametric design space towards acceptable simultaneous excitation and reception of a microfluidic sample over a wide frequency band ranging from 13C to 1H, i.e., 125–500 MHz in an 11.74 T magnet. The detector achieves 37% of the performance of a comparably sized, tuned and matched resonator, and a linewidth of 17 ppb using standard magnet shims. The use of broadband detectors circumvents numerous difficulties introduced by multi-resonant RF detector circuits, including sample loading effects on matching, channel isolation, and field distortion.
Collapse
|
5
|
Waiczies S, Prinz C, Starke L, Millward JM, Delgado PR, Rosenberg J, Nazaré M, Waiczies H, Pohlmann A, Niendorf T. Functional Imaging Using Fluorine ( 19F) MR Methods: Basic Concepts. Methods Mol Biol 2021; 2216:279-299. [PMID: 33476007 PMCID: PMC9703275 DOI: 10.1007/978-1-0716-0978-1_17] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Kidney-associated pathologies would greatly benefit from noninvasive and robust methods that can objectively quantify changes in renal function. In the past years there has been a growing incentive to develop new applications for fluorine (19F) MRI in biomedical research to study functional changes during disease states. 19F MRI represents an instrumental tool for the quantification of exogenous 19F substances in vivo. One of the major benefits of 19F MRI is that fluorine in its organic form is absent in eukaryotic cells. Therefore, the introduction of exogenous 19F signals in vivo will yield background-free images, thus providing highly selective detection with absolute specificity in vivo. Here we introduce the concept of 19F MRI, describe existing challenges, especially those pertaining to signal sensitivity, and give an overview of preclinical applications to illustrate the utility and applicability of this technique for measuring renal function in animal models.This chapter is based upon work from the COST Action PARENCHIMA, a community-driven network funded by the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers. This introduction chapter is complemented by two separate chapters describing the experimental procedure and data analysis.
Collapse
Affiliation(s)
- Sonia Waiczies
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine (MDC) in the Helmholtz Association, Berlin, Germany.
| | - Christian Prinz
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine (MDC) in the Helmholtz Association, Berlin, Germany
| | - Ludger Starke
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine (MDC) in the Helmholtz Association, Berlin, Germany
| | - Jason M Millward
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine (MDC) in the Helmholtz Association, Berlin, Germany
| | - Paula Ramos Delgado
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine (MDC) in the Helmholtz Association, Berlin, Germany
| | - Jens Rosenberg
- The National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL, USA
| | - Marc Nazaré
- Medicinal Chemistry, Leibniz-Forschungsinstitut für Molekulare Pharmakologie (FMP), Berlin, Germany
| | | | - Andreas Pohlmann
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine (MDC) in the Helmholtz Association, Berlin, Germany
- Siemens Healthcare, Berlin, Germany
| | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine (MDC) in the Helmholtz Association, Berlin, Germany
| |
Collapse
|
6
|
Wilcox M, Wright SM, McDougall M. A Review of Non-1H RF Receive Arrays in Magnetic Resonance Imaging and Spectroscopy. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2020; 1:290-300. [PMID: 35402958 PMCID: PMC8975242 DOI: 10.1109/ojemb.2020.3030531] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 09/15/2020] [Accepted: 09/25/2020] [Indexed: 11/16/2022] Open
Abstract
It is now common practice to use radiofrequency (RF) coils to increase the signal-to-noise ratio (SNR) in 1H magnetic resonance imaging and spectroscopy experiments. Use of array coils for non-1H experiments, however, has been historically more limited despite the fact that these nuclei suffer inherently lower sensitivity and could benefit greatly from an increased SNR. Recent advancements in receiver technology and increased support from scanner manufacturers have now opened greater options for the use of array coils for non-1H magnetic resonance experiments. This paper reviews the research in adopting array coil technology with an emphasis on studies of the most commonly studied non-1H nuclei including 31P, 13C, 23Na, and 19F. These nuclei offer complementary information to 1H imaging and spectroscopy and have proven themselves important in the study of numerous disease processes. While recent work with non-1H array coils has shown promising results, the technology is not yet widely utilized and should see substantial developments in the coming years.
Collapse
|
7
|
Parsa J, Mohammadzadeh M. Design and fabrication of a new multi-loop saddle coil for 1.5 T MRI. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2019; 90:114707. [PMID: 31779412 DOI: 10.1063/1.5114813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Accepted: 10/21/2019] [Indexed: 06/10/2023]
Abstract
Radiofrequency coils provide high-resolution magnetic resonance (MR) imaging of human tissues. A small RF coil produces MR images with a higher resolution compared to the commercial volume MR coils from mass limited samples. Signal to noise ratio (SNR) plays a key role in the optimal design of receiver radiofrequency coils. In this work, we present a three-loop saddle coil suitable for MR imaging of digits of the human body. The geometry of the introduced coil is optimized to achieve the highest SNR. The coil performance is evaluated through comparing the measured SNR maps of the optimal coil derived from MR images of a saline phantom with the corresponding measured SNR maps of a commercial head coil in axial and sagittal slices. Results verify that the image SNR of the introduced coil is 3.4 times higher than that of the head coil and 2 times higher than that of the similar saddle coils represented in the literature recently. To validate the measured results, SNR maps of the introduced saddle and head coils were simulated and their SNR difference was compared with the corresponding measured data of the two coils. Results show that the simulated and measured data are in agreement with less than 11.8% error.
Collapse
Affiliation(s)
- J Parsa
- Department of Energy Engineering, Sharif University of Technology, Tehran 1458889694, Iran
| | - M Mohammadzadeh
- Radiation in Medicine Department, Shahid Beheshti University, Tehran 1983969411, Iran
| |
Collapse
|
8
|
Davoodi H, Jouda M, Korvink JG, MacKinnon N, Badilita V. Broadband and multi-resonant sensors for NMR. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2019; 112-113:34-54. [PMID: 31481158 DOI: 10.1016/j.pnmrs.2019.05.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2019] [Revised: 05/08/2019] [Accepted: 05/08/2019] [Indexed: 06/10/2023]
Abstract
It has always been of considerable interest to study the nuclear magnetic resonance response of multiple nuclei simultaneously, whether these signals arise from internuclear couplings within the same molecule, or from uncoupled nuclei within sample mixtures. The literature contains numerous uncorrelated reports on techniques employed to achieve multi-nuclear NMR detection. This paper consolidates the subset of techniques in which single coil detectors are utilized, and highlights the strengths and weaknesses of each approach, at the same time pointing the way towards future developments in the field of multi-nuclear NMR. We compare the different multi-nuclear NMR techniques in terms of performance, and present a guide to NMR probe designers towards application-based optimum design. We also review the applicability of micro-coils in the context of multi-nuclear methods. Micro-coils benefit from compact geometries and exhibit lower impedance, which provide new opportunities and challenges for the NMR probe designer.
Collapse
Affiliation(s)
- Hossein Davoodi
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany
| | - Mazin Jouda
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany
| | - Jan G Korvink
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany.
| | - Neil MacKinnon
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany
| | - Vlad Badilita
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany.
| |
Collapse
|
9
|
A dual 1H/19F birdcage coil for small animals at 7 T MRI. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2019; 32:79-87. [DOI: 10.1007/s10334-018-00733-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Revised: 12/14/2018] [Accepted: 12/21/2018] [Indexed: 12/22/2022]
|
10
|
Maunder A, Rao M, Robb F, Wild JM. Comparison of MEMS switches and PIN diodes for switched dual tuned RF coils. Magn Reson Med 2018; 80:1746-1753. [PMID: 29524235 PMCID: PMC6120476 DOI: 10.1002/mrm.27156] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2017] [Revised: 02/05/2018] [Accepted: 02/05/2018] [Indexed: 11/12/2022]
Abstract
PURPOSE To evaluate the performance of micro-electromechanical systems (MEMS) switches against PIN diodes for switching a dual-tuned RF coil between 19 F and 1 H resonant frequencies for multi-nuclear lung imaging. METHODS A four-element fixed-phase and amplitude transmit-receive RF coil was constructed to provide homogeneous excitation across the lungs, and to serve as a test system for various switching methods. The MR imaging and RF performance of the coil when switched between the 19 F and 1 H frequencies using MEMS switches, PIN diodes and hardwired configurations were compared. RESULTS The performance of the coil with MEMS or PIN diode switching was comparable in terms of RF measurements, transmit efficiency and image SNR on both 19 F and 1 H nuclei. When the coil was not switched to the resonance frequency of the respective nucleus being imaged, reductions in the transmit efficiency were observed of 32% at the 19 F frequency and 12% at the 1 H frequency. The coil provides transmit field homogeneity of ±12.9% at the 1 H frequency and ±14.4% at the 19 F frequency in phantoms representing the thorax with the air space of the lungs filled with perfluoropropane gas. CONCLUSION MEMS and PIN diodes were found to provide comparable performance in on-state configuration, while MEMS were more robust in off-state high-powered operation (>1 kW), providing higher isolation and requiring a lower DC switching voltage than is needed for reverse biasing of PIN diodes. In addition, clear benefits of switching between the 19 F and 1 H resonances were demonstrated, despite the proximity of their Larmor frequencies.
Collapse
Affiliation(s)
- Adam Maunder
- Unit of Academic Radiology, University of SheffieldUnited Kingdom
| | - Madhwesha Rao
- Unit of Academic Radiology, University of SheffieldUnited Kingdom
| | - Fraser Robb
- Unit of Academic Radiology, University of SheffieldUnited Kingdom
- GE HealthcareAuroraOhio
| | - Jim M. Wild
- Unit of Academic Radiology, University of SheffieldUnited Kingdom
| |
Collapse
|
11
|
Couch MJ, Ball IK, Li T, Fox MS, Biman B, Albert MS. 19 F MRI of the Lungs Using Inert Fluorinated Gases: Challenges and New Developments. J Magn Reson Imaging 2018; 49:343-354. [PMID: 30248212 DOI: 10.1002/jmri.26292] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Revised: 07/23/2018] [Accepted: 07/26/2018] [Indexed: 12/27/2022] Open
Abstract
Fluorine-19 (19 F) MRI using inhaled inert fluorinated gases is an emerging technique that can provide functional images of the lungs. Inert fluorinated gases are nontoxic, abundant, relatively inexpensive, and the technique can be performed on any MRI scanner with broadband multinuclear imaging capabilities. Pulmonary 19 F MRI has been performed in animals, healthy human volunteers, and in patients with lung disease. In this review, the technical requirements of 19 F MRI are discussed, along with various imaging approaches used to optimize the image quality. Lung imaging is typically performed in humans using a gas mixture containing 79% perfluoropropane (PFP) or sulphur hexafluoride (SF6 ) and 21% oxygen. In lung diseases, such as asthma, chronic obstructive pulmonary disease (COPD), and cystic fibrosis (CF), ventilation defects are apparent in regions that the inhaled gas cannot access. 19 F lung images are typically acquired in a single breath-hold, or in a time-resolved, multiple breath fashion. The former provides measurements of the ventilation defect percent (VDP), while the latter provides measurements of gas replacement (ie, fractional ventilation). Finally, preliminary comparisons with other functional lung imaging techniques are discussed, such as Fourier decomposition MRI and hyperpolarized gas MRI. Overall, functional 19 F lung MRI is expected to complement existing proton-based structural imaging techniques, and the combination of structural and functional lung MRI will provide useful outcome measures in the future management of pulmonary diseases in the clinic. Level of Evidence: 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:343-354.
Collapse
Affiliation(s)
- Marcus J Couch
- Translational Medicine Program, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Iain K Ball
- Philips Electronics Australia, North Ryde, Sydney, Australia
| | - Tao Li
- Department of Chemistry, Lakehead University, Thunder Bay, Ontario, Canada
| | - Matthew S Fox
- Imaging Program, Lawson Health Research Institute, London, Ontario, Canada.,Department of Medical Biophysics, University of Western Ontario, London, Ontario, Canada
| | - Birubi Biman
- Thunder Bay Regional Health Sciences Centre, Thunder Bay, Ontario, Canada.,Northern Ontario School of Medicine, Thunder Bay, Ontario, Canada.,Department of Medicine, McMaster University, Hamilton, Ontario, Canada
| | - Mitchell S Albert
- Department of Chemistry, Lakehead University, Thunder Bay, Ontario, Canada.,Northern Ontario School of Medicine, Thunder Bay, Ontario, Canada.,Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada
| |
Collapse
|
12
|
A Novel Metamaterial-Inspired RF-coil for Preclinical Dual-Nuclei MRI. Sci Rep 2018; 8:9190. [PMID: 29907834 PMCID: PMC6003915 DOI: 10.1038/s41598-018-27327-y] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2017] [Accepted: 05/24/2018] [Indexed: 11/12/2022] Open
Abstract
In this paper, we propose, design and test a new dual-nuclei RF-coil inspired by wire metamaterial structures. The coil operates as a result of resonant excitation of hybridized eigenmodes in multimode flat periodic structures comprising several coupled thin metal strips. It was shown that the field distribution of the coil (i.e. penetration depth) can be controlled independently at two different Larmor frequencies by selecting a proper eigenmode in each of two mutually orthogonal periodic structures. The proposed coil requires no lumped capacitors to be tuned and matched. In order to demonstrate the performance of the new design, an experimental preclinical coil for 19F/1H imaging of small animals at 7.05T was engineered and tested on a homogeneous liquid phantom and in-vivo. The results demonstrate that the coil was both well tuned and matched at two Larmor frequencies and allowed image acquisition at both nuclei. In an in-vivo experiment, it was shown that without retuning the setup it was subsequently possible to obtain anatomical 1H images of a mouse under anesthesia with 19F images of a tiny tube filled with a fluorine-containing liquid and attached to the body of the mouse.
Collapse
|
13
|
Li N, Liu S, Hu X, Luo C, Zhang X, Li Y. Electromagnetic Field and Radio Frequency Circuit Co-Simulation for Magnetic Resonance Imaging Dual-Tuned Radio Frequency Coils. IEEE TRANSACTIONS ON MAGNETICS 2018; 54:5100504. [PMID: 29755135 PMCID: PMC5947962 DOI: 10.1109/tmag.2017.2758518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Electromagnetic (EM) field simulation plays a key role in the design of magnetic resonance imaging radio frequency (RF) coils. However, the values of the components in tuning and matching circuits often need to be iterated repeatedly in the conventional simulation method in order to achieve optimal scattering parameters. This leads to a time-consuming optimization to tune and match RF coils, particularly dual-tuned coils that are comprised of multiple lumped elements. A method combining EM field simulation and circuit simulation was employed in this paper, which can dramatically improve simulation efficiency for the optimization of the values of the lumped elements and corresponding EM field distribution. A systematical theoretical analysis of the co-simulation method was presented. To validate the accuracy and efficiency of the co-simulation method, a comparison study was conducted between the conventional simulation and the proposed co-simulation approaches.
Collapse
Affiliation(s)
- Nan Li
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
- Department of Biomedical Engineering, Chongqing University of Technology, Chongqing 400054, China
| | - Shengping Liu
- Department of Biomedical Engineering, Chongqing University of Technology, Chongqing 400054, China
| | - Xiaoqing Hu
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Chao Luo
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Xiaoliang Zhang
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA 94158 USA
- UCSF/UC Berkeley Joint Graduate Group in Bioengineering, San Francisco, CA 94158 USA
| | - Ye Li
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| |
Collapse
|
14
|
Choi CH, Hong SM, Ha Y, Shah NJ. Design and construction of a novel 1H/ 19F double-tuned coil system using PIN-diode switches at 9.4T. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2017; 279:11-15. [PMID: 28411437 DOI: 10.1016/j.jmr.2017.04.005] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Revised: 03/09/2017] [Accepted: 04/05/2017] [Indexed: 06/07/2023]
Abstract
A double-tuned 1H/19F coil using PIN-diode switches was developed and its performance evaluated. The is a key difference from the previous developments being that this design used a PIN-diode switch in series with an additionally inserted inductor in parallel to one of the capacitors on the loop. The probe was adjusted to 19F when the reverse bias voltage was applied (PIN-diode OFF), whilst it was switched to 1H when forward current was flowing (PIN-diode ON). S-parameters and Q-factors of single- and double-tuned coils were examined and compared with/without a phantom on the bench. Imaging experiments were carried out on a 9.4T preclinical scanner. All coils were tuned at resonance frequencies and matched well. It is shown that the Q-ratio and SNR of double-tuned coil at 19F frequency are nearly as good as those of a single-tuned coil. Since the operating frequency was tuned to 19F when the PIN-diodes were turned off, losses due to PIN-diodes were substantially lower resulting in the provision of excellent image quality of X-nuclei.
Collapse
Affiliation(s)
- Chang-Hoon Choi
- Institute of Neuroscience and Medicine - 4, Forschungszentrum Juelich, 52425 Juelich, Germany.
| | - Suk-Min Hong
- Institute of Neuroscience and Medicine - 4, Forschungszentrum Juelich, 52425 Juelich, Germany
| | - YongHyun Ha
- Institute of Neuroscience and Medicine - 4, Forschungszentrum Juelich, 52425 Juelich, Germany
| | - N Jon Shah
- Institute of Neuroscience and Medicine - 4, Forschungszentrum Juelich, 52425 Juelich, Germany; Faculty of Medicine, Department of Neurology, RWTH Aachen University, JARA, Aachen, Germany; Department of Electrical and Computer Systems Engineering, School of Psychological Sciences, Monash University, Melbourne, Victoria, Australia; Monash Biomedical Imaging, School of Psychological Sciences, Monash University, Melbourne, Victoria, Australia
| |
Collapse
|
15
|
Advances in Monitoring Cell-Based Therapies with Magnetic Resonance Imaging: Future Perspectives. Int J Mol Sci 2017; 18:ijms18010198. [PMID: 28106829 PMCID: PMC5297829 DOI: 10.3390/ijms18010198] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2016] [Revised: 01/05/2017] [Accepted: 01/10/2017] [Indexed: 01/07/2023] Open
Abstract
Cell-based therapies are currently being developed for applications in both regenerative medicine and in oncology. Preclinical, translational, and clinical research on cell-based therapies will benefit tremendously from novel imaging approaches that enable the effective monitoring of the delivery, survival, migration, biodistribution, and integration of transplanted cells. Magnetic resonance imaging (MRI) offers several advantages over other imaging modalities for elucidating the fate of transplanted cells both preclinically and clinically. These advantages include the ability to image transplanted cells longitudinally at high spatial resolution without exposure to ionizing radiation, and the possibility to co-register anatomical structures with molecular processes and functional changes. However, since cellular MRI is still in its infancy, it currently faces a number of challenges, which provide avenues for future research and development. In this review, we describe the basic principle of cell-tracking with MRI; explain the different approaches currently used to monitor cell-based therapies; describe currently available MRI contrast generation mechanisms and strategies for monitoring transplanted cells; discuss some of the challenges in tracking transplanted cells; and suggest future research directions.
Collapse
|
16
|
Giovannetti G, Flori A, Marsigli F, De Marchi D, Frijia F, Giannoni M, Kusmic C, Positano V, Aquaro GD, Menichetti L. A radiofrequency system for in vivo hyperpolarized 13 C MRS experiments in mice with a 3T MRI clinical scanner. SCANNING 2016; 38:710-719. [PMID: 27059822 DOI: 10.1002/sca.21319] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2015] [Accepted: 03/20/2016] [Indexed: 06/05/2023]
Abstract
Hyperpolarized carbon-13 magnetic resonance spectroscopy (MRS) is a powerful tool to explore tissue metabolic state, by permitting the study of intermediary metabolism of biomolecules in vivo. However, a number of technological problems still limit this technology and need innovative solutions. In particular, the low molar concentration of derivate metabolites give rise to low signal-to-noise ratio (SNR), which makes the design and development of dedicated radiofrequency (RF) coils a fundamental task. In this article, the authors describe the simulation and the design of a RF coils configuration for MR experiments in mice, constituted by a 1 H whole body volume RF coil for imaging and a 13 C single circular loop surface RF coil for performing 13 C acquisitions. After the building, the RF system was employed in an in vivo experiment in a mouse injected with hyperpolarized [1-13 C]pyruvate by using a 3 T clinical MR scanner. SCANNING 38:710-719, 2016. © 2016 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Giulio Giovannetti
- Institute of Clinical Physiology, National Research Council (CNR), Pisa, Italy
- Fondazione CNR/Regione Toscana G. Monasterio, Pisa, Italy
| | - Alessandra Flori
- Fondazione CNR/Regione Toscana G. Monasterio, Pisa, Italy
- Institute of Life Sciences, Scuola Superiore Sant'Anna, Pisa, Italy
| | - Fabio Marsigli
- Department of Information Engineering, University of Pisa, Pisa, Italy
| | | | | | - Massimo Giannoni
- Institute of Clinical Physiology, National Research Council (CNR), Pisa, Italy
| | - Claudia Kusmic
- Institute of Clinical Physiology, National Research Council (CNR), Pisa, Italy
| | | | | | - Luca Menichetti
- Institute of Clinical Physiology, National Research Council (CNR), Pisa, Italy
- Fondazione CNR/Regione Toscana G. Monasterio, Pisa, Italy
| |
Collapse
|
17
|
Bouchlaka MN, Ludwig KD, Gordon JW, Kutz MP, Bednarz BP, Fain SB, Capitini CM. (19)F-MRI for monitoring human NK cells in vivo. Oncoimmunology 2016; 5:e1143996. [PMID: 27467963 DOI: 10.1080/2162402x.2016.1143996] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2015] [Revised: 01/11/2016] [Accepted: 01/13/2016] [Indexed: 01/13/2023] Open
Abstract
The availability of clinical-grade cytokines and artificial antigen-presenting cells has accelerated interest in using natural killer (NK) cells as adoptive cellular therapy (ACT) for cancer. One of the technological shortcomings of translating therapies from animal models to clinical application is the inability to effectively and non-invasively track these cells after infusion in patients. We have optimized the nonradioactive isotope fluorine-19 ((19)F) as a means to label and track NK cells in preclinical models using magnetic resonance imaging (MRI). Human NK cells were expanded with interleukin (IL)-2 and labeled in vitro with increasing concentrations of (19)F. Doses as low as 2 mg/mL (19)F were detected by MRI. NK cell viability was only decreased at 8 mg/mL (19)F. No effects on NK cell cytotoxicity against K562 leukemia cells were observed with 2, 4 or 8 mg/mL (19)F. Higher doses of (19)F, 4 mg/mL and 8 mg/mL, led to an improved (19)F signal by MRI with 3 × 10(11) (19)F atoms per NK cell. The 4 mg/mL (19)F labeling had no effect on NK cell function via secretion of granzyme B or interferon gamma (IFNγ), compared to NK cells exposed to vehicle alone. (19)F-labeled NK cells were detectable immediately by MRI after intratumoral injection in NSG mice and up to day 8. When (19)F-labeled NK cells were injected subcutaneously, we observed a loss of signal through time at the site of injection suggesting NK cell migration to distant organs. The (19)F perfluorocarbon is a safe and effective reagent for monitoring the persistence and trafficking of NK cell infusions in vivo, and may have potential for developing novel imaging techniques to monitor ACT for cancer.
Collapse
Affiliation(s)
- Myriam N Bouchlaka
- Department of Pediatrics, Carbone Cancer Center, University of Wisconsin School of Medicine and Public Health , Madison, WI, USA
| | - Kai D Ludwig
- Department of Medical Physics, Carbone Cancer Center, University of Wisconsin School of Medicine and Public Health , Madison, WI, USA
| | - Jeremy W Gordon
- Department of Medical Physics, Carbone Cancer Center, University of Wisconsin School of Medicine and Public Health , Madison, WI, USA
| | - Matthew P Kutz
- Department of Pediatrics, Carbone Cancer Center, University of Wisconsin School of Medicine and Public Health , Madison, WI, USA
| | - Bryan P Bednarz
- Department of Medical Physics, Carbone Cancer Center, University of Wisconsin School of Medicine and Public Health , Madison, WI, USA
| | - Sean B Fain
- Department of Medical Physics, Carbone Cancer Center, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA; Department of Radiology, Carbone Cancer Center, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA; Department of Biomedical Engineering, Carbone Cancer Center, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
| | - Christian M Capitini
- Department of Pediatrics, Carbone Cancer Center, University of Wisconsin School of Medicine and Public Health , Madison, WI, USA
| |
Collapse
|
18
|
Schmieder AH, Caruthers SD, Keupp J, Wickline SA, Lanza GM. Recent Advances in 19Fluorine Magnetic Resonance Imaging with Perfluorocarbon Emulsions. ENGINEERING (BEIJING, CHINA) 2015; 1:475-489. [PMID: 27110430 PMCID: PMC4841681 DOI: 10.15302/j-eng-2015103] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
The research roots of 19fluorine (19F) magnetic resonance imaging (MRI) date back over 35 years. Over that time span, 1H imaging flourished and was adopted worldwide with an endless array of applications and imaging approaches, making magnetic resonance an indispensable pillar of biomedical diagnostic imaging. For many years during this timeframe, 19F imaging research continued at a slow pace as the various attributes of the technique were explored. However, over the last decade and particularly the last several years, the pace and clinical relevance of 19F imaging has exploded. In part, this is due to advances in MRI instrumentation, 19F/1H coil designs, and ultrafast pulse sequence development for both preclinical and clinical scanners. These achievements, coupled with interest in the molecular imaging of anatomy and physiology, and combined with a cadre of innovative agents, have brought the concept of 19F into early clinical evaluation. In this review, we attempt to provide a slice of this rich history of research and development, with a particular focus on liquid perfluorocarbon compound-based agents.
Collapse
Affiliation(s)
- Anne H. Schmieder
- Division of Cardiology, Washington University School of Medical, St. Louis, MO 63110, USA
| | - Shelton D. Caruthers
- Toshiba Medical Research Institute USA, Inc., Cleveland, OH 44143, USA
- Department of Biomedical Engineering, Washington University, St. Louis, MO 63130, USA
| | - Jochen Keupp
- Philips Research Hamburg, Hamburg 22335, Germany
| | - Samuel A. Wickline
- Division of Cardiology, Washington University School of Medical, St. Louis, MO 63110, USA
| | - Gregory M. Lanza
- Division of Cardiology, Washington University School of Medical, St. Louis, MO 63110, USA
- Correspondence author.
| |
Collapse
|
19
|
Ji Y, Waiczies H, Winter L, Neumanova P, Hofmann D, Rieger J, Mekle R, Waiczies S, Niendorf T. Eight-channel transceiver RF coil array tailored for ¹H/¹⁹F MR of the human knee and fluorinated drugs at 7.0 T. NMR IN BIOMEDICINE 2015; 28:726-737. [PMID: 25916199 DOI: 10.1002/nbm.3300] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2014] [Revised: 03/09/2015] [Accepted: 03/11/2015] [Indexed: 06/04/2023]
Abstract
The purpose of this study was to evaluate the feasibility of an eight-channel dual-tuned transceiver surface RF coil array for combined (1)H/(19)F MR of the human knee at 7.0 T following application of (19)F-containing drugs. The (1)H/(19)F RF coil array includes a posterior module with two (1)H loop elements and two anterior modules, each consisting of one (1)H and two (19)F elements. The decoupling of neighbor elements is achieved by a shared capacitor. Electromagnetic field simulations were performed to afford uniform transmission fields and to be in accordance with RF safety guidelines. Localized (19)F MRS was conducted with 47 and 101 mmol/L of flufenamic acid (FA) – a (19)F-containing non-steroidal anti-inflammatory drug – to determine T1 and T2 and to study the (19)F signal-to-dose relationship. The suitability of the proposed approach for (1)H/(19)F MR was examined in healthy subjects. Reflection coefficients of each channel were less than -17 dB and coupling between channels was less than -11 dB. Q(L)/Q(U) was less than 0.5 for all elements. MRS results demonstrated signal stability with 1% variation. T1 and T2 relaxation times changed with concentration of FA: T1 /T2 = 673/31 ms at 101 mmol/L and T1 /T2 = 616/26 ms at 47 mmol/L. A uniform signal and contrast across the patella could be observed in proton imaging. The sensitivity of the RF coil enabled localization of FA ointment administrated to the knee with an in-plane spatial resolution of (1.5 × 1.5) mm(2) achieved in a total scan time of approximately three minutes, which is well suited for translational human studies. This study shows the feasibility of combined (1)H/(19)F MRI of the knee at 7.0 T and proposes T1 and T2 mapping methods for quantifying fluorinated drugs in vivo. Further technological developments are necessary to promote real-time bioavailability studies and quantification of (19)F-containing medicinal compounds in vivo.
Collapse
Affiliation(s)
- Yiyi Ji
- Berlin Ultrahigh Field Facility (BUFF), Max Delbrück Center for Molecular Medicine, Berlin, Germany
- Institute of Biophysics and Biomedical Engineering, Faculty of Sciences of the University of Lisbon, Lisbon, Portugal
| | - Helmar Waiczies
- Berlin Ultrahigh Field Facility (BUFF), Max Delbrück Center for Molecular Medicine, Berlin, Germany
- MRI.TOOLS GmbH, Berlin, Germany
| | - Lukas Winter
- Berlin Ultrahigh Field Facility (BUFF), Max Delbrück Center for Molecular Medicine, Berlin, Germany
| | - Pavla Neumanova
- Berlin Ultrahigh Field Facility (BUFF), Max Delbrück Center for Molecular Medicine, Berlin, Germany
| | - Daniela Hofmann
- Berlin Ultrahigh Field Facility (BUFF), Max Delbrück Center for Molecular Medicine, Berlin, Germany
| | | | - Ralf Mekle
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Sonia Waiczies
- Berlin Ultrahigh Field Facility (BUFF), Max Delbrück Center for Molecular Medicine, Berlin, Germany
| | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility (BUFF), Max Delbrück Center for Molecular Medicine, Berlin, Germany
- Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine, Berlin, Germany
| |
Collapse
|
20
|
Goette MJ, Lanza GM, Caruthers SD, Wickline SA. Improved quantitative (19) F MR molecular imaging with flip angle calibration and B1 -mapping compensation. J Magn Reson Imaging 2014; 42:488-94. [PMID: 25425244 DOI: 10.1002/jmri.24812] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2014] [Accepted: 11/07/2014] [Indexed: 12/22/2022] Open
Abstract
PURPOSE To improve (19) F flip angle calibration and compensate for B1 inhomogeneities in quantitative (19) F MRI of sparse molecular epitopes with perfluorocarbon (PFC) nanoparticle (NP) emulsion contrast agents. MATERIALS AND METHODS Flip angle sweep experiments on PFC-NP point source phantoms with three custom-designed (19) F/(1) H dual-tuned coils revealed a difference in required power settings for (19) F and (1) H nuclei, which was used to calculate a calibration ratio specific for each coil. An image-based correction technique was developed using B1 -field mapping on (1) H to correct for (19) F and (1) H images in two phantom experiments. RESULTS Optimized (19) F peak power differed significantly from that of (1) H power for each coil (P < 0.05). A ratio of (19) F/(1) H power settings yielded a coil-specific and spatially independent calibration value (surface: 1.48 ± 0.06; semicylindrical: 1.71 ± 0.02, single-turn-solenoid: 1.92 ± 0.03). (1) H-image-based B1 correction equalized the signal intensity of (19) F images for two identical (19) F PFC-NP samples placed in different parts of the field, which were offset significantly by ~66% (P < 0.001), before correction. CONCLUSION (19) F flip angle calibration and B1 -mapping compensations to the (19) F images employing the more abundant (1) H signal as a basis for correction resulted in a significant change in the quantification of sparse (19) F MR signals from targeted PFC NP emulsions.
Collapse
Affiliation(s)
- Matthew J Goette
- Department of Biomedical Engineering, Washington University in St. Louis, Missouri, USA
| | - Gregory M Lanza
- Department of Biomedical Engineering, Washington University in St. Louis, Missouri, USA.,Department of Medicine, Washington University in St. Louis, Missouri, USA
| | - Shelton D Caruthers
- Department of Biomedical Engineering, Washington University in St. Louis, Missouri, USA.,Philips Healthcare, Cleveland, Ohio, USA
| | - Samuel A Wickline
- Department of Biomedical Engineering, Washington University in St. Louis, Missouri, USA.,Department of Medicine, Washington University in St. Louis, Missouri, USA
| |
Collapse
|
21
|
Cell tracking using 19F magnetic resonance imaging: Technical aspects and challenges towards clinical applications. Eur Radiol 2014; 25:726-35. [DOI: 10.1007/s00330-014-3474-5] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2013] [Revised: 10/03/2014] [Accepted: 10/16/2014] [Indexed: 01/03/2023]
|
22
|
Tirotta I, Dichiarante V, Pigliacelli C, Cavallo G, Terraneo G, Bombelli FB, Metrangolo P, Resnati G. (19)F magnetic resonance imaging (MRI): from design of materials to clinical applications. Chem Rev 2014; 115:1106-29. [PMID: 25329814 DOI: 10.1021/cr500286d] [Citation(s) in RCA: 327] [Impact Index Per Article: 32.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Ilaria Tirotta
- Laboratory of Nanostructured Fluorinated Materials (NFMLab), Department of Chemistry, Materials, and Chemical Engineering "Giulio Natta" and ‡Fondazione Centro Europeo Nanomedicina, Politecnico di Milano , Milan 20131, Italy
| | | | | | | | | | | | | | | |
Collapse
|
23
|
Otake Y, Soutome Y, Hirata K, Ochi H, Bito Y. Double-tuned radiofrequency coil for (19)F and (1)H imaging. Magn Reson Med Sci 2014; 13:199-205. [PMID: 24990464 DOI: 10.2463/mrms.2013-0094] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
We developed a double-tuned radiofrequency (RF) coil using a novel circuit method to double tune for fluorine-19 (19F) and 1H magnetic resonance imaging, whose frequencies are very close to each other. The RF coil consists of 3 parallel-connected series inductor capacitor circuits. A computer simulation for our double-tuned RF coil with a phantom demonstrated that the coil has tuned resonant frequency and high sensitivity for both 19F and 1H. Drug distribution was visualized at 7 tesla using this RF coil and a rat administered perfluoro 15-crown-5-ether emulsion. The double-tune RF coil we developed may be a powerful tool for 19F and 1H imaging.
Collapse
|
24
|
MR cholangiography demonstrates unsuspected rapid biliary clearance of nanoparticles in rodents: implications for clinical translation. NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE 2014; 10:1385-8. [PMID: 24832959 DOI: 10.1016/j.nano.2014.05.001] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2014] [Revised: 05/02/2014] [Accepted: 05/02/2014] [Indexed: 02/02/2023]
Abstract
Due to their small size, lower cost, short reproduction cycle, and genetic manipulation, rodents have been widely used to test the safety and efficacy for pharmaceutical development in human disease. In this report, MR cholangiography demonstrated an unexpected rapid (<5 min) biliary elimination of gadolinium-perfluorocarbon nanoparticles (approximately 250 nm diameter) into the common bile duct and small intestine of rats, which is notably different from nanoparticle clearance patterns in larger animals and humans. Unawareness of this dissimilarity in nanoparticle clearance mechanisms between small animals and humans may lead to fundamental errors in predicting nanoparticle efficacy, pharmacokinetics, biodistribution, bioelimination, and toxicity. From the clinical editor: Comprehensive understanding of nanoparticle clearance is a clear prerequisite for human applications of nanomedicine-based therapeutic approaches. Through a novel use of MR cholangiography, this study demonstrates unusually rapid hepatic clearance of gadolinium-perfluorocarbon nanoparticles in rodents, in a pattern that is different than what is observed in larger animals and humans, raising awareness of important differences between common rodent-based models and larger mammals.
Collapse
|
25
|
Waiczies H, Lepore S, Drechsler S, Qadri F, Purfürst B, Sydow K, Dathe M, Kühne A, Lindel T, Hoffmann W, Pohlmann A, Niendorf T, Waiczies S. Visualizing brain inflammation with a shingled-leg radio-frequency head probe for 19F/1H MRI. Sci Rep 2013; 3:1280. [PMID: 23412352 PMCID: PMC3573344 DOI: 10.1038/srep01280] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2012] [Accepted: 01/29/2013] [Indexed: 12/22/2022] Open
Abstract
Magnetic resonance imaging (MRI) provides the opportunity of tracking cells in vivo. Major challenges in dissecting cells from the recipient tissue and signal sensitivity constraints albeit exist. In this study, we aimed to tackle these limitations in order to study inflammation in autoimmune encephalomyelitis. We constructed a very small dual-tunable radio frequency (RF) birdcage probe tailored for 19F (fluorine) and 1H (proton) MR mouse neuroimaging. The novel design eliminated the need for extra electrical components on the probe structure and afforded a uniform -field as well as good SNR. We employed fluorescently-tagged 19F nanoparticles and could study the dynamics of inflammatory cells between CNS and lymphatic system during development of encephalomyelitis, even within regions of the brain that are otherwise not easily visualized by conventional probes. 19F/1H MR Neuroimaging will allow us to study the nature of immune cell infiltration during brain inflammation over an extensive period of time.
Collapse
Affiliation(s)
- Helmar Waiczies
- Berlin Ultrahigh Field Facility (BUFF), Max Delbrück Center for Molecular Medicine, Germany.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Ahrens ET, Zhong J. In vivo MRI cell tracking using perfluorocarbon probes and fluorine-19 detection. NMR IN BIOMEDICINE 2013; 26:860-71. [PMID: 23606473 PMCID: PMC3893103 DOI: 10.1002/nbm.2948] [Citation(s) in RCA: 97] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2012] [Revised: 01/29/2013] [Accepted: 02/21/2013] [Indexed: 05/08/2023]
Abstract
This article presents a brief review of preclinical in vivo cell-tracking methods and applications using perfluorocarbon (PFC) probes and fluorine-19 ((19) F) MRI detection. Detection of the (19) F signal offers high cell specificity and quantification ability in spin density-weighted MR images. We discuss the compositions of matter, methods and applications of PFC-based cell tracking using ex vivo and in situ PFC labeling in preclinical studies of inflammation and cellular therapeutics. We also address the potential applicability of (19) F cell tracking to clinical trials.
Collapse
Affiliation(s)
- Eric T Ahrens
- Department of Biological Sciences and Pittsburgh NMR Center for Biomedical Research, Carnegie Mellon University, Pittsburgh, PA 15213, USA.
| | | |
Collapse
|
27
|
Diou O, Tsapis N, Fattal E. Targeted nanotheranostics for personalized cancer therapy. Expert Opin Drug Deliv 2012; 9:1475-87. [DOI: 10.1517/17425247.2012.736486] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|