Saucedo A, Thomas MA. Single-shot diffusion trace spectroscopic imaging using radial echo planar trajectories. Magn Reson Med 2024; 92:926-944. [PMID: 38725389 DOI: 10.1002/mrm.30125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 03/05/2024] [Accepted: 04/04/2024] [Indexed: 06/27/2024]
Abstract
PURPOSE Demonstrate the feasibility and evaluate the performance of single-shot diffusion trace-weighted radial echo planar spectroscopic imaging (Trace DW-REPSI) for quantifying the trace ADC in phantom and in vivo using a 3T clinical scanner. THEORY AND METHODS Trace DW-REPSI datasets were acquired in 10 phantom and 10 healthy volunteers, with a maximum b-value of 1601 s/mm2 and diffusion time of 10.75 ms. The self-navigation properties of radial acquisitions were used for corrections of shot-to-shot phase and frequency shift fluctuations of the raw data. In vivo trace ADCs of total NAA (tNAA), total creatine (tCr), and total choline (tCho) extrapolated to pure gray and white matter fractions were compared, as well as trace ADCs estimated in voxels within white or gray matter-dominant regions. RESULTS Trace ADCs in phantom show excellent agreement with reported values, and in vivo ADCs agree well with the expected differences between gray and white matter. For tNAA, tCr, and tCho, the trace ADCs extrapolated to pure gray and white matter ranged from 0.18-0.27 and 0.26-0.38 μm2/ms, respectively. In sets of gray and white matter-dominant voxels, the values ranged from 0.21 to 0.27 and 0.24 to 0.31 μm2/ms, respectively. The overestimated trace ADCs from this sequence can be attributed to the short diffusion time. CONCLUSION This study presents the first demonstration of the single-shot diffusion trace-weighted spectroscopic imaging sequence using radial echo planar trajectories. The Trace DW-REPSI sequence could provide an estimate of the trace ADC in a much shorter scan time compared to conventional approaches that require three separate measurements.
Collapse
Affiliation(s)
- Andres Saucedo
- Radiological Sciences, University of California at Los Angeles, Los Angeles, California, USA
- Physics and Biology in Medicine Interdepartmental Graduate Program, David Geffen School of Medicine, University of California at Los Angeles, Los Angeles, California, USA
| | - M Albert Thomas
- Radiological Sciences, University of California at Los Angeles, Los Angeles, California, USA
- Physics and Biology in Medicine Interdepartmental Graduate Program, David Geffen School of Medicine, University of California at Los Angeles, Los Angeles, California, USA
- Psychiatry, University of California at Los Angeles, Los Angeles, California, USA
| |
Collapse
|
2
|
Saucedo A, Sayre J, Thomas MA. Single-shot diffusion trace-weighted MR spectroscopy: Comparison with unipolar and bipolar diffusion-weighted point-resolved spectroscopy. NMR IN BIOMEDICINE 2024; 37:e5090. [PMID: 38148181 PMCID: PMC10957108 DOI: 10.1002/nbm.5090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Revised: 11/17/2023] [Accepted: 11/19/2023] [Indexed: 12/28/2023]
Abstract
This study demonstrates the feasibility and performance of the point-resolved spectroscopy (PRESS)-based, single-shot diffusion trace-weighted sequence in quantifying the trace apparent diffusion coefficient (ADC) in phantom and in vivo using a 3-T MRI/MRS scanner. The single-shot diffusion trace-weighted PRESS sequence was implemented and compared with conventional diffusion-weighted (DW)-PRESS variants using bipolar and unipolar diffusion-sensitizing gradients. Nine phantom datasets were acquired using each sequence, and seven volunteers were scanned in three different brain regions to determine the range and variability of trace ADC values, and to allow a comparison of trace ADCs among the sequences. This sequence results in a comparatively stable range of trace ADC values that are statistically significantly higher than those produced from unipolar and bipolar DW-PRESS sequences. Only total n-acetylaspartate, total creatine, and total choline were reliably estimated in all sequences with Cramér-Rao lower bounds of, at most, 20%. The larger trace ADCs from the single-shot sequences are probably attributable to the shorter diffusion time relative to the other sequences. Overall, this study presents the first demonstration of the single-shot diffusion trace-weighted sequence in a clinical scanner at 3 T. The results show excellent agreement of phantom trace ADCs computed with all sequences, and in vivo ADCs agree well with the expected differences between gray and white matter. The diffusion trace-weighted sequence could provide an estimate of the trace ADC in a shorter scan time (by nearly a factor of 3) compared with conventional DW-PRESS approaches that require three separate orthogonal directions.
Collapse
Affiliation(s)
- Andres Saucedo
- Radiological Sciences, University of California at Los
Angeles, Los Angeles, CA, United States
- Physics and Biology in Medicine, University of California
at Los Angeles, Los Angeles, CA, United States
| | - James Sayre
- Radiological Sciences, University of California at Los
Angeles, Los Angeles, CA, United States
| | - M. Albert Thomas
- Radiological Sciences, University of California at Los
Angeles, Los Angeles, CA, United States
- Physics and Biology in Medicine, University of California
at Los Angeles, Los Angeles, CA, United States
| |
Collapse
|
3
|
Carrell T, McDougall MP. Multi-channel magnetic resonance spectroscopy graphical user interface (McMRSGUI). PLoS One 2024; 19:e0299142. [PMID: 38416774 PMCID: PMC10901321 DOI: 10.1371/journal.pone.0299142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Accepted: 02/06/2024] [Indexed: 03/01/2024] Open
Abstract
This work introduces an open-sourced graphical user interface (GUI) software enabling the combination of multi-channel magnetic resonance spectroscopy data with different literature-based methods for the improvement of the quality and reliability of combined spectra. The multi-channel magnetic resonance spectroscopy graphical user interface (McMRSGUI) is a MATLAB-based spectroscopy processing GUI equipped to load multi-channel MRS data, pre-process, combine, and export combined data for evaluation with open-source quantification software (jMRUI). A literature-based, decision-tree process was incorporated into the combination type selection to serve as a guide to minimize spectral distortion in selecting between weighting methods. Multi-channel, simulated spectra were combined with the different combination techniques and evaluated for spectral distortion to validate the code. The incorporation of the combination methods into a single processing software enables multi-channel magnetic resonance spectroscopy (MRS) data to be combined and compared for improved spectral quality with little user knowledge of combination techniques. Through the spectral peak distortion simulation of the combination methods, combined signal-to-noise ratio (SNR) values from the literature were verified. The spectral peak distortion simulation provides a secondary tool for researchers to estimate the spectral SNR levels when spectral distortion could occur and use this knowledge to further guide the selection of their combination technique. The McMRSGUI provides a software toolkit for evaluating multi-channel MRS data and their combination. Simulations evaluating spectral distortion at different noise levels were performed for each combination method to validate the GUI and demonstrate a method for researchers to assess the combined SNR levels at which they could be introducing spectral distortion.
Collapse
Affiliation(s)
- Travis Carrell
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, United States of America
| | - Mary P McDougall
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, United States of America
| |
Collapse
|
4
|
An L, Shen J. In vivo magnetic resonance spectroscopy by transverse relaxation encoding with narrowband decoupling. Sci Rep 2023; 13:12211. [PMID: 37500714 PMCID: PMC10374641 DOI: 10.1038/s41598-023-39375-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 07/25/2023] [Indexed: 07/29/2023] Open
Abstract
Cell pathology in neuropsychiatric disorders has mainly been accessible by analyzing postmortem tissue samples. Although molecular transverse relaxation informs local cellular microenvironment via molecule-environment interactions, precise determination of the transverse relaxation times of molecules with scalar couplings (J), such as glutamate and glutamine, has been difficult using in vivo magnetic resonance spectroscopy (MRS) technologies, whose approach to measuring transverse relaxation has not changed for decades. We introduce an in vivo MRS technique that utilizes frequency-selective editing pulses to achieve homonuclear decoupled chemical shift encoding in each column of the acquired two-dimensional dataset, freeing up the entire row dimension for transverse relaxation encoding with J-refocusing. This results in increased spectral resolution, minimized background signals, and markedly broadened dynamic range for transverse relaxation encoding. The in vivo within-subject coefficients of variation for the transverse relaxation times of glutamate and glutamine, measured using the proposed method in the human brain at 7 T, were found to be approximately 4%. Since glutamate predominantly resides in glutamatergic neurons and glutamine in glia in the brain, this noninvasive technique provides a way to probe cellular pathophysiology in neuropsychiatric disorders for characterizing disease progression and monitoring treatment response in a cell type-specific manner in vivo.
Collapse
Affiliation(s)
- Li An
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, MD, USA.
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Building 10, Room 3D46, 10 Center Drive, MSC 1216, Bethesda, MD, 20892-1216, USA.
| | - Jun Shen
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, MD, USA
| |
Collapse
|
5
|
Detection of 13C labeling of glutamate and glutamine in human brain by proton magnetic resonance spectroscopy. Sci Rep 2022; 12:8729. [PMID: 35610241 PMCID: PMC9130156 DOI: 10.1038/s41598-022-12654-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2022] [Accepted: 05/13/2022] [Indexed: 11/09/2022] Open
Abstract
A proton magnetic resonance spectroscopy (MRS) technique was used to measure 13C enrichments of glutamate and glutamine in a 3.5 × 1.8 × 2 cm3 voxel placed in the dorsal anterior cingulate cortex of five healthy participants after oral administration of [U-13C]glucose. Strong pseudo singlets of glutamate and glutamine were induced to enhance the signal strength of glutamate and glutamine. This study demonstrated that 13C labeling of glutamate and glutamine can be measured with the high sensitivity and spatial resolution of 1H MRS using a proton-only MRS technique with standard commercial hardware. Furthermore, it is feasible to measure 13C labeling of glutamate and glutamine in limbic structures, which play major roles in behavioral and emotional responses and whose abnormalities are involved in many neuropsychiatric disorders.
Collapse
|
6
|
Hupfeld KE, Hyatt HW, Alvarez Jerez P, Mikkelsen M, Hass CJ, Edden RAE, Seidler RD, Porges EC. In Vivo Brain Glutathione is Higher in Older Age and Correlates with Mobility. Cereb Cortex 2021; 31:4576-4594. [PMID: 33959751 PMCID: PMC8408448 DOI: 10.1093/cercor/bhab107] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Revised: 03/25/2021] [Accepted: 03/28/2021] [Indexed: 12/12/2022] Open
Abstract
Brain markers of oxidative damage increase with advancing age. In response, brain antioxidant levels may also increase with age, although this has not been well investigated. Here, we used edited magnetic resonance spectroscopy to quantify endogenous levels of glutathione (GSH, one of the most abundant brain antioxidants) in 37 young [mean: 21.8 (2.5) years; 19 female] and 23 older adults [mean: 72.8 (8.9) years; 19 female]. Accounting for age-related atrophy, we identified higher frontal and sensorimotor GSH levels for the older compared with the younger adults. For the older adults only, higher sensorimotor (but not frontal) GSH was correlated with poorer balance and gait. This suggests a regionally specific relationship between higher brain oxidative stress levels and motor performance declines with age. We suggest these findings reflect an upregulation of GSH in response to increasing brain oxidative stress with normal aging. Together, these results provide insight into age differences in brain antioxidant levels and implications for motor function.
Collapse
Affiliation(s)
- K E Hupfeld
- Department of Applied Physiology and Kinesiology, University of Florida, Gainesville, FL 32603, USA
| | - H W Hyatt
- Department of Applied Physiology and Kinesiology, University of Florida, Gainesville, FL 32603, USA
| | - P Alvarez Jerez
- Department of Applied Physiology and Kinesiology, University of Florida, Gainesville, FL 32603, USA
| | - M Mikkelsen
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD 21205, USA
| | - C J Hass
- Department of Applied Physiology and Kinesiology, University of Florida, Gainesville, FL 32603, USA
| | - R A E Edden
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD 21205, USA
| | - R D Seidler
- Department of Applied Physiology and Kinesiology, University of Florida, Gainesville, FL 32603, USA
- Department of Neurology, University of Florida, Gainesville, FL 32611, USA
| | - E C Porges
- Department of Clinical and Health Psychology, University of Florida, Gainesville, FL 32603, USA
| |
Collapse
|
7
|
Coil Combination of Multichannel Single Voxel Magnetic Resonance Spectroscopy with Repeatedly Sampled In Vivo Data. Molecules 2021; 26:molecules26133896. [PMID: 34202302 PMCID: PMC8272065 DOI: 10.3390/molecules26133896] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2021] [Revised: 06/17/2021] [Accepted: 06/22/2021] [Indexed: 12/01/2022] Open
Abstract
Magnetic resonance spectroscopy (MRS), as a noninvasive method for molecular structure determination and metabolite detection, has grown into a significant tool in clinical applications. However, the relatively low signal-to-noise ratio (SNR) limits its further development. Although the multichannel coil and repeated sampling are commonly used to alleviate this problem, there is still potential room for promotion. One possible improvement way is combining these two acquisition methods so that the complementary of them can be well utilized. In this paper, a novel coil-combination method, average smoothing singular value decomposition, is proposed to further improve the SNR by introducing repeatedly sampled signals into multichannel coil combination. Specifically, the sensitivity matrix of each sampling was pretreated by whitened singular value decomposition (WSVD), then the smoothing was performed along the repeated samplings’ dimension. By comparing with three existing popular methods, Brown, WSVD, and generalized least squares, the proposed method showed better performance in one phantom and 20 in vivo spectra.
Collapse
|
8
|
Xavier A, Arteaga de Castro C, Andia ME, Luijten PR, Klomp DW, Fillmer A, Prompers JJ. Metabolite cycled liver 1 H MRS on a 7 T parallel transmit system. NMR IN BIOMEDICINE 2020; 33:e4343. [PMID: 32515151 PMCID: PMC7379278 DOI: 10.1002/nbm.4343] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Revised: 05/08/2020] [Accepted: 05/12/2020] [Indexed: 05/03/2023]
Abstract
INTRODUCTION Single-voxel 1 H MRS in body applications often suffers from respiratory and other motion induced phase and frequency shifts, which lead to incoherent averaging and hence to suboptimal results. METHODS Here we show the application of metabolite cycling (MC) for liver STEAM-localized 1 H MRS on a 7 T parallel transmit system, using eight transmit-receive fractionated dipole antennas with 16 additional, integrated receive loops. MC-STEAM measurements were made in six healthy, lean subjects and compared with STEAM measurements using VAPOR water suppression. Measurements were performed during free breathing and during synchronized breathing, for which the subjects did breathe in between the MRS acquisitions. Both intra-session repeatability and inter-session reproducibility of liver lipid quantification with MC-STEAM and VAPOR-STEAM were determined. RESULTS The preserved water signal in MC-STEAM allowed for robust phase and frequency correction of individual acquisitions before averaging, which resulted in in vivo liver spectra that were of equal quality when measurements were made with free breathing or synchronized breathing. Intra-session repeatability and inter-session reproducibility of liver lipid quantification were better for MC-STEAM than for VAPOR-STEAM. This may also be explained by the more robust phase and frequency correction of the individual MC-STEAM acquisitions as compared with the VAPOR-STEAM acquisitions, for which the low-signal-to-noise ratio lipid signals had to be used for the corrections. CONCLUSION Non-water-suppressed MC-STEAM on a 7 T system with parallel transmit is a promising approach for 1 H MRS applications in the body that are affected by motion, such as in the liver, and yields better repeatability and reproducibility compared with water-suppressed measurements.
Collapse
Affiliation(s)
- Aline Xavier
- Department of Radiology, Imaging DivisionUniversity Medical Center UtrechtUtrechtThe Netherlands
- Biomedical Imaging Center, Pontificia Universidad Católica de ChileSantiagoChile
- Millennium Nucleus for Cardiovascular Magnetic ResonanceSantiagoChile
| | | | - Marcelo E. Andia
- Biomedical Imaging Center, Pontificia Universidad Católica de ChileSantiagoChile
- Millennium Nucleus for Cardiovascular Magnetic ResonanceSantiagoChile
| | - Peter R. Luijten
- Department of Radiology, Imaging DivisionUniversity Medical Center UtrechtUtrechtThe Netherlands
| | - Dennis W. Klomp
- Department of Radiology, Imaging DivisionUniversity Medical Center UtrechtUtrechtThe Netherlands
| | - Ariane Fillmer
- Department of Radiology, Imaging DivisionUniversity Medical Center UtrechtUtrechtThe Netherlands
- Physikalisch‐Technische Bundesanstalt (PTB)BerlinGermany
| | - Jeanine J. Prompers
- Department of Radiology, Imaging DivisionUniversity Medical Center UtrechtUtrechtThe Netherlands
| |
Collapse
|
9
|
An L, Araneta MF, Victorino M, Shen J. Determination of Brain Metabolite
T
1
Without Interference From Macromolecule Relaxation. J Magn Reson Imaging 2020; 52:1352-1359. [PMID: 32618104 PMCID: PMC10108383 DOI: 10.1002/jmri.27259] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2020] [Revised: 05/29/2020] [Accepted: 06/01/2020] [Indexed: 01/02/2023] Open
Abstract
BACKGROUND J-coupled metabolites are often measured at a predetermined echo time in the presence of macromolecule signals, which complicates the measurement of metabolite T1 . PURPOSE To evaluate the feasibility and benefits of measuring metabolite T1 relaxation times without changing the overlapping macromolecule baseline signals. STUDY TYPE Prospective. SUBJECTS Five healthy volunteers (three females and two males; age = 27 ± 7 years). FIELD STRENGTH/SEQUENCE 7T scanner using a point resolved spectroscopy (PRESS)-based spectral editing MR spectroscopy (MRS) sequence with inversion recovery (IR). ASSESSMENT F-tests were performed to evaluate if the new approach, which fitted all the spectra together and used the same baselines for the three different IR settings, significantly reduced the variances of the metabolite T1 values compared to a conventional fitting approach. STATISTICAL TESTS Cramer-Rao lower bound (CRLB), within-subject coefficient of variation, and F-test. RESULTS The T1 relaxation times of N-acetylaspartate (NAA), total creatine (tCr), total choline (tCho), myo-inositol (mI), and glutamate (Glu) were determined with CRLB values below 6%. Glutamine (Gln) T1 was determined with a 17% CRLB, and the T1 of γ-aminobutyric acid (GABA) was determined with a 34% CRLB. The new approach significantly reduced the variances (F-test P < 0.05) of NAA, Glu, Gln, tCr, tCho, and mI T1 s compared to the conventional approach. DATA CONCLUSION Keeping macromolecule signals intact by using only long IR times allowed the use of a single macromolecule spectral model for different IR settings and significantly reduced the variances of NAA, Glu, Gln, tCr, tCho, and mI T1 s. LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY STAGE: 1.
Collapse
Affiliation(s)
- Li An
- Section on Magnetic Resonance Spectroscopy National Institute of Mental Health, National Institutes of Health Bethesda Maryland USA
| | - Maria Ferraris Araneta
- Section on Magnetic Resonance Spectroscopy National Institute of Mental Health, National Institutes of Health Bethesda Maryland USA
| | - Milalynn Victorino
- Section on Magnetic Resonance Spectroscopy National Institute of Mental Health, National Institutes of Health Bethesda Maryland USA
| | - Jun Shen
- Section on Magnetic Resonance Spectroscopy National Institute of Mental Health, National Institutes of Health Bethesda Maryland USA
| |
Collapse
|
10
|
An L, Araneta MF, Victorino M, Shen J. Signal enhancement of glutamine and glutathione by single-step spectral editing. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 316:106756. [PMID: 32521478 PMCID: PMC7385909 DOI: 10.1016/j.jmr.2020.106756] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Revised: 05/08/2020] [Accepted: 05/27/2020] [Indexed: 06/11/2023]
Abstract
A single-step spectral editing approach using an always-on editing pulse was proposed to enhance the signals of strongly coupled spins. Specifically, a single-step spectral editing sequence with an always-on editing pulse applied at 2.12 ppm was used to enhance glutamine (Gln) and glutathione (GSH) signals at TE = 56 ms on a 7 T scanner. Density matrix simulations demonstrated that the current method (TE = 56 ms) led to large signal enhancement of at least 61% for Gln and 51% for GSH compared to a previous single-step method (TE = 106 ms). Monte Carlo simulations showed that the current method reduced noise-originated variations by 31% for Gln and 26% for GSH compared to a previous three-step spectral editing method from which the present method was derived.
Collapse
Affiliation(s)
- Li An
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, MD, United States.
| | - Maria Ferraris Araneta
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, MD, United States
| | - Milalynn Victorino
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, MD, United States
| | - Jun Shen
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, MD, United States
| |
Collapse
|
11
|
Wilcox M, Wright SM, McDougall M. A Review of Non-1H RF Receive Arrays in Magnetic Resonance Imaging and Spectroscopy. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2020; 1:290-300. [PMID: 35402958 PMCID: PMC8975242 DOI: 10.1109/ojemb.2020.3030531] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 09/15/2020] [Accepted: 09/25/2020] [Indexed: 11/16/2022] Open
Abstract
It is now common practice to use radiofrequency (RF) coils to increase the signal-to-noise ratio (SNR) in 1H magnetic resonance imaging and spectroscopy experiments. Use of array coils for non-1H experiments, however, has been historically more limited despite the fact that these nuclei suffer inherently lower sensitivity and could benefit greatly from an increased SNR. Recent advancements in receiver technology and increased support from scanner manufacturers have now opened greater options for the use of array coils for non-1H magnetic resonance experiments. This paper reviews the research in adopting array coil technology with an emphasis on studies of the most commonly studied non-1H nuclei including 31P, 13C, 23Na, and 19F. These nuclei offer complementary information to 1H imaging and spectroscopy and have proven themselves important in the study of numerous disease processes. While recent work with non-1H array coils has shown promising results, the technology is not yet widely utilized and should see substantial developments in the coming years.
Collapse
|
12
|
Mallikourti V, Cheung SM, Gagliardi T, Masannat Y, Heys SD, He J. Optimal Phased-Array Signal Combination For Polyunsaturated Fatty Acids Measurement In Breast Cancer Using Multiple Quantum Coherence MR Spectroscopy At 3T. Sci Rep 2019; 9:9259. [PMID: 31239527 PMCID: PMC6592938 DOI: 10.1038/s41598-019-45710-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Accepted: 06/05/2019] [Indexed: 11/09/2022] Open
Abstract
Polyunsaturated fatty acid (PUFA), a key marker in breast cancer, is non-invasively quantifiable using multiple quantum coherence (MQC) magnetic resonance spectroscopy (MRS) at the expense of losing half of the signal. Signal combination for phased array coils provides potential pathways to enhance the signal to noise ratio (SNR), with current algorithms developed for conventional brain MRS. Since PUFA spectra and the biochemical environment in the breast deviate significantly from those in the brain, we set out to identify the optimal algorithm for PUFA in breast cancer. Combination algorithms were compared using PUFA spectra from 17 human breast tumour specimens, 15 healthy female volunteers, and 5 patients with breast cancer on a clinical 3 T MRI scanner. Adaptively Optimised Combination (AOC) yielded the maximum SNR improvement in specimens (median, 39.5%; interquartile range: 35.5-53.2%, p < 0.05), volunteers (82.4 ± 37.4%, p < 0.001), and patients (median, 61%; range: 34-105%, p < 0.05), while independent from voxel volume (rho = 0.125, p = 0.632), PUFA content (rho = 0.256, p = 0.320) or water/fat ratio (rho = 0.353, p = 0.165). Using AOC, acquisition in patients is 1.5 times faster compared to non-noise decorrelated algorithms. Therefore, AOC is the most suitable current algorithm to improve SNR or accelerate the acquisition of PUFA MRS from breast in a clinical setting.
Collapse
Affiliation(s)
- Vasiliki Mallikourti
- Institute of Medical Sciences, School of Medicine, University of Aberdeen, Aberdeen, UK.
| | - Sai Man Cheung
- Institute of Medical Sciences, School of Medicine, University of Aberdeen, Aberdeen, UK
| | - Tanja Gagliardi
- Department of Clinical Radiology, Aberdeen Royal Infirmary, Aberdeen, UK
- Department of Radiology, Royal Marsden Hospital, London, UK
| | | | - Steven D Heys
- Institute of Medical Sciences, School of Medicine, University of Aberdeen, Aberdeen, UK
- Breast Unit, Aberdeen Royal Infirmary, Aberdeen, UK
| | - Jiabao He
- Institute of Medical Sciences, School of Medicine, University of Aberdeen, Aberdeen, UK
| |
Collapse
|
13
|
Li N, Li L, Zhang Y, Ferraris Araneta M, Johnson C, Shen J. Quantification of in vivo transverse relaxation of glutamate in the frontal cortex of human brain by radio frequency pulse-driven longitudinal steady state. PLoS One 2019; 14:e0215210. [PMID: 30995237 PMCID: PMC6469797 DOI: 10.1371/journal.pone.0215210] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Accepted: 03/28/2019] [Indexed: 12/13/2022] Open
Abstract
PURPOSE The principal excitatory neurotransmitter glutamate plays an important role in many central nervous system disorders. Because glutamate resides predominantly in glutamatergic neurons, its relaxation properties reflect the intracellular environment of glutamatergic neurons. This study developed an improved echo time-independent technique for measuring transverse relaxation time and demonstrated that this radio frequency (RF)-driven longitudinal steady state technique can reliably measure glutamate transverse relaxation in the frontal cortex, where structural and functional abnormalities have been associated with psychiatric symptoms. METHOD Bloch and Monte Carlo simulations were performed to improve and optimize the RF-driven, longitudinal, steady-state (MARzss) technique to significantly shorten scan time and increase measurement precision. Optimized four-flip angle measurements at 0°,12°, 24°, and 36° with matched repetition time were used in nine human subjects (6F, 3M; 27-49 years old) at 7 Tesla. Longitudinal and transverse relaxation rates for glutamate were measured from a 2 x 2 x 2 cm3 voxel placed in three different brain regions: gray matter-dominated medial prefrontal lobe, white matter-dominated left frontal lobe, and gray matter-dominated occipital lobe. RESULTS Compared to the original MARzss technique, the scan time per voxel for measuring glutamate transverse relaxation was shortened by more than 50%. In the medial frontal, left frontal, and occipital voxels, the glutamate T2 was found to be 117.5±12.9 ms (mean ± standard deviation, n = 9), 107.3±12.1 (n = 9), and 124.4±16.6 ms (n = 8), respectively. CONCLUSIONS The improvements described in this study make the MARZSS technique a viable tool for reliably measuring glutamate relaxation from human subjects in a typical clinical setting. It is expected that this improved technique can be applied to characterize the intracellular environment of glutamatergic neurons in a variety of brain disorders.
Collapse
Affiliation(s)
- Ningzhi Li
- Section on Magnetic Spectroscopy, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, United States of America
| | - Linqing Li
- Functional Magnetic Resonance Imaging Core Facility, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, United States of America
| | - Yan Zhang
- Magnetic Resonance Spectroscopy Core, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, United States of America
| | - Maria Ferraris Araneta
- Magnetic Resonance Spectroscopy Core, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, United States of America
| | - Christopher Johnson
- Section on Magnetic Spectroscopy, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, United States of America
| | - Jun Shen
- Section on Magnetic Spectroscopy, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, United States of America
- Magnetic Resonance Spectroscopy Core, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, United States of America
| |
Collapse
|
14
|
Zhu Z, Zhu X, Ohliger MA, Tang S, Cao P, Carvajal L, Autry AW, Li Y, Kurhanewicz J, Chang S, Aggarwal R, Munster P, Xu D, Larson PEZ, Vigneron DB, Gordon JW. Coil combination methods for multi-channel hyperpolarized 13C imaging data from human studies. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2019; 301:73-79. [PMID: 30851668 PMCID: PMC7170546 DOI: 10.1016/j.jmr.2019.01.015] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Revised: 01/19/2019] [Accepted: 01/30/2019] [Indexed: 05/23/2023]
Abstract
Effective coil combination methods for human hyperpolarized 13C spectroscopy multi-channel data had been relatively unexplored. This study implemented and tested several coil combination methods, including (1) the sum-of-squares (SOS), (2) singular value decomposition (SVD), (3) Roemer method by using reference peak area as a sensitivity map (RefPeak), and (4) Roemer method by using ESPIRiT-derived sensitivity map (ESPIRiT). These methods were evaluated by numerical simulation, thermal phantom experiments, and human cancer patient studies. Overall, the SVD, RefPeak, and ESPIRiT methods demonstrated better accuracy and robustness than the SOS method. Extracting complex pyruvate signal provides an easy and excellent approximation of the coil sensitivity map while maintaining valuable phase information of the coil-combined data.
Collapse
Affiliation(s)
- Zihan Zhu
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States; UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, San Francisco and University of California, Berkeley, CA, United States.
| | - Xucheng Zhu
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States; UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, San Francisco and University of California, Berkeley, CA, United States
| | - Michael A Ohliger
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States
| | - Shuyu Tang
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States; UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, San Francisco and University of California, Berkeley, CA, United States
| | - Peng Cao
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States
| | - Lucas Carvajal
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States
| | - Adam W Autry
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States
| | - Yan Li
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States
| | - John Kurhanewicz
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States
| | - Susan Chang
- Department of Medicine, University of California, San Francisco, CA, United States
| | - Rahul Aggarwal
- Department of Medicine, University of California, San Francisco, CA, United States
| | - Pamela Munster
- Department of Medicine, University of California, San Francisco, CA, United States
| | - Duan Xu
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States
| | - Peder E Z Larson
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States
| | - Daniel B Vigneron
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States
| | - Jeremy W Gordon
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States
| |
Collapse
|
15
|
Vareth M, Lupo J, Larson P, Nelson S. A comparison of coil combination strategies in 3D multi-channel MRSI reconstruction for patients with brain tumors. NMR IN BIOMEDICINE 2018; 31:e3929. [PMID: 30168205 PMCID: PMC6290901 DOI: 10.1002/nbm.3929] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2017] [Revised: 03/01/2018] [Accepted: 03/07/2018] [Indexed: 05/12/2023]
Abstract
The goal of this study was to find the most robust algorithm for a phase-sensitive coil combination of 3D single-cycle and lactate-edited, multi-channel H-1 point-resolved spectroscopy (PRESS) localized echo planar spectroscopic imaging (EPSI) data for clinical applications in the brain. Data were acquired over 5-10 minutes at 3T using 8- or 32-channel array coils. Peak referencing with residual water and N-acetyl-aspartate, first-point phasing, generalized least squared (GLS) and whitened singular-value decomposition (WSVD) combination algorithms were evaluated relative to unsuppressed water with data from a phantom, six volunteers and 55 patients with brain tumors. Comparison metrics were signal-to-noise ratio, coefficient of variance and percent signal increase. Where residual water was present, using it as a reference peak for phasing and weighting factors from an imaging calibration scan gave the best overall performance. Greater improvement was seen for large selected volumes (>720 cm3 ) and for the 32-channel array (25%) compared with the 8-channel array (19%). Applying voxel-by-voxel phase corrections produced a larger increase in performance for the 32- versus 8-channel coil. We conclude that, for clinically relevant 3D H-1 PRESS localized EPSI studies, the most robust technique employed individual phase maps generated from high residual water and individual amplitude maps generated from calibration scans.
Collapse
Affiliation(s)
- Maryam Vareth
- UC Berkeley–UCSF Graduate Program in Bioengineering, University of California, Berkeley and University of California, San Francisco, California, USA
- Surbeck Laboratory of Advanced Imaging, Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA
| | - Janine Lupo
- UC Berkeley–UCSF Graduate Program in Bioengineering, University of California, Berkeley and University of California, San Francisco, California, USA
- Surbeck Laboratory of Advanced Imaging, Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA
| | - Peder Larson
- UC Berkeley–UCSF Graduate Program in Bioengineering, University of California, Berkeley and University of California, San Francisco, California, USA
- Surbeck Laboratory of Advanced Imaging, Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA
| | - Sarah Nelson
- UC Berkeley–UCSF Graduate Program in Bioengineering, University of California, Berkeley and University of California, San Francisco, California, USA
- Surbeck Laboratory of Advanced Imaging, Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA
| |
Collapse
|
16
|
Vareth M, Lupo J, Larson P, Nelson S. A comparison of coil combination strategies in 3D multi-channel MRSI reconstruction for patients with brain tumors. NMR IN BIOMEDICINE 2018. [PMID: 30168205 DOI: 10.1002/nbm.3929e3929] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
The goal of this study was to find the most robust algorithm for a phase-sensitive coil combination of 3D single-cycle and lactate-edited, multi-channel H-1 point-resolved spectroscopy (PRESS) localized echo planar spectroscopic imaging (EPSI) data for clinical applications in the brain. Data were acquired over 5-10 minutes at 3T using 8- or 32-channel array coils. Peak referencing with residual water and N-acetyl-aspartate, first-point phasing, generalized least squared (GLS) and whitened singular-value decomposition (WSVD) combination algorithms were evaluated relative to unsuppressed water with data from a phantom, six volunteers and 55 patients with brain tumors. Comparison metrics were signal-to-noise ratio, coefficient of variance and percent signal increase. Where residual water was present, using it as a reference peak for phasing and weighting factors from an imaging calibration scan gave the best overall performance. Greater improvement was seen for large selected volumes (>720 cm3 ) and for the 32-channel array (25%) compared with the 8-channel array (19%). Applying voxel-by-voxel phase corrections produced a larger increase in performance for the 32- versus 8-channel coil. We conclude that, for clinically relevant 3D H-1 PRESS localized EPSI studies, the most robust technique employed individual phase maps generated from high residual water and individual amplitude maps generated from calibration scans.
Collapse
Affiliation(s)
- Maryam Vareth
- UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, Berkeley and University of California, San Francisco, California, USA
- Surbeck Laboratory of Advanced Imaging, Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA
| | - Janine Lupo
- UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, Berkeley and University of California, San Francisco, California, USA
- Surbeck Laboratory of Advanced Imaging, Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA
| | - Peder Larson
- UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, Berkeley and University of California, San Francisco, California, USA
- Surbeck Laboratory of Advanced Imaging, Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA
| | - Sarah Nelson
- UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, Berkeley and University of California, San Francisco, California, USA
- Surbeck Laboratory of Advanced Imaging, Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA
| |
Collapse
|
17
|
An L, Araneta MF, Johnson C, Shen J. Simultaneous measurement of glutamate, glutamine, GABA, and glutathione by spectral editing without subtraction. Magn Reson Med 2018; 80:1776-1786. [PMID: 29575059 PMCID: PMC6107387 DOI: 10.1002/mrm.27172] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2017] [Revised: 02/02/2018] [Accepted: 02/16/2018] [Indexed: 12/27/2022]
Abstract
PURPOSE To simultaneously measure glutamate, glutamine, γ-aminobutyric acid (GABA), and glutathione using spectral editing without subtraction at 7T. METHODS A novel spectral editing approach was proposed to simultaneously measure glutamate, glutamine, GABA, and glutathione using a TE of 56 ms at 7T. By numerical optimization of sequence timing in the presence of an editing pulse, the 4 metabolites all form relatively intense pseudo singlets with maximized peak amplitudes and minimized peak linewidths in 1 of the 3 interleaved spectra. For measuring glutamate, glutamine, and glutathione, the editing pulse targets the H3 protons of these metabolites near 2.12 parts per million. Both GABA H2 and H4 resonances are fully utilized in spectral fitting. RESULTS Concentration levels (/[total creatine]) of glutamate, glutamine, GABA, and glutathione from an 8 mL voxel in the pregenual anterior cingulate cortex of 5 healthy volunteers were found to be 1.26 ± 0.13, 0.33 ± 0.06, 0.13 ± 0.03, and 0.27 ± 0.03, respectively, with within-subject coefficient of variation at 3.2%, 8.2%, 7.1%, and 10.2%, respectively. The total scan time was less than 4.5 min. CONCLUSIONS The proposed new technique does not require data subtraction. The 3 major metabolites of the glutamatergic and GABAergic systems and the oxidative stress marker glutathione were all measured in 1 short scan with high precision.
Collapse
Affiliation(s)
- Li An
- National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland
| | | | - Christopher Johnson
- National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland
| | - Jun Shen
- National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland
| |
Collapse
|
18
|
7T 1H-MRS in major depressive disorder: a Ketamine Treatment Study. Neuropsychopharmacology 2018; 43:1908-1914. [PMID: 29748628 PMCID: PMC6046051 DOI: 10.1038/s41386-018-0057-1] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2017] [Revised: 03/09/2018] [Accepted: 03/23/2018] [Indexed: 01/08/2023]
Abstract
The glutamatergic modulator ketamine has striking and rapid antidepressant effects in major depressive disorder (MDD), but its mechanism of action remains unknown. Proton magnetic resonance spectroscopy (1H-MRS) is the only non-invasive method able to directly measure glutamate levels in vivo; in particular, glutamate and glutamine metabolite concentrations are separable by 1H-MRS at 7T. This double-blind, placebo-controlled, crossover study that included 1H-MRS scans at baseline and at 24 h post ketamine and post-placebo infusions sought to determine glutamate levels in the pregenual anterior cingulate (pgACC) of 20 medication-free MDD subjects and 17 healthy volunteers (HVs) 24 h post ketamine administration, and to evaluate any other measured metabolite changes, correlates, or predictors of antidepressant response. Metabolite levels were compared at three scan times (baseline, post-ketamine, and post-placebo) in HVs and MDD subjects at 7T using a 1H-MRS sequence specifically optimized for glutamate. No significant between-group differences in 1H-MRS-measured metabolites were observed at baseline. Antidepressant response was not predicted by baseline glutamate levels. Our results suggest that any infusion-induced increases in glutamate at the 24-h post ketamine time point were below the sensitivity of the current technique; that these increases may occur in different brain regions than the pgACC; or that subgroups of MDD subjects may exist that have a differential glutamate response to ketamine.
Collapse
|
19
|
方 旭, 边 云, 陈 士, 陆 建, 王 莉. 氢质子磁共振波谱对胰腺癌分析及其分化程度相关性研究. Shijie Huaren Xiaohua Zazhi 2017; 25:1454-1460. [DOI: 10.11569/wcjd.v25.i16.1454] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
目的 探讨氢质子磁共振波谱(1H magnetic resonance spectroscopy, 1H MRS)分析胰腺癌瘤体与瘤旁导管上皮内瘤变(pancreatic duct intraepithelial neoplasia, Pan IN)病变及肿瘤不同分化程度的代谢物差异.
方法 病理确诊为胰腺导管腺癌的患者47例(低分化17例、中分化30例), 术前均行1H MRS检查, 使用呼吸门控的抑水点分辨波谱序列对肿瘤的瘤体、瘤旁组织进行1H MRS检测. 分析出每个1H MRS数据的胆碱峰(choline-containing metabolites, CCM)/脂肪峰(lipid, Lip)、胆固醇及不饱和脂肪酸峰(cholesterol and unsaturated fatty acids, Chol+Unsat)/Lip、Chol+Unsat/CCM的峰下面积比, 采用配对样本t检验比较瘤体和瘤旁组织的代谢物差异, 用独立样本t检验比较胰腺导管腺癌低分化组和中分化组的代谢物差异.
结果 同时获得瘤体和瘤旁数据共24例, 瘤体组织的CCM/Lip高于瘤旁组织(0.266±0.084 vs 0.200±0.081), 瘤体组织的Chol+Unsat/Lip高于瘤旁组织(0.324±0.109 vs 0.258±0.092), 差异均有统计学意义(P<0.05), 瘤体和瘤旁组织的Chol+Unsat/CCM无统计学差异; 胰腺低分化和中分化导管腺癌的CCM/Lip、Chol+Unsat/Lip、Chol+Unsat/CCM无统计学差异.
结论 1H MRS对鉴别胰腺癌与瘤旁Pan IN病变具有一定意义, 但不可预测其肿瘤分化程度.
Collapse
|
20
|
An L, Li S, Shen J. Simultaneous determination of metabolite concentrations, T 1 and T 2 relaxation times. Magn Reson Med 2017; 78:2072-2081. [PMID: 28164364 DOI: 10.1002/mrm.26612] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2016] [Revised: 12/08/2016] [Accepted: 12/27/2016] [Indexed: 12/25/2022]
Abstract
PURPOSE To simultaneously measure concentration and T1 and T2 values of metabolites in the human brain in a single scan session. METHODS A new pulse sequence with multiple variable acquisition parameters was proposed to encode metabolite T1 and T2 information into the acquired data. A linear combination-fitting algorithm was developed in-house to simultaneously determine metabolite concentrations and relaxation times. RESULTS Concentration, T1 , and T2 values of N-acetyl-aspartate, total creatine, total choline, and glutamate were reliably measured in the frontal gray matter and white matter regions of nine healthy volunteers at 7 tesla in less than 10 minutes of scan time per voxel. T1 and T2 values of glutamine, as well as T1 of glutathione, were also measured in the frontal gray matter region with reasonable precision. CONCLUSION The proposed technique allows multiparametric characterization of brain metabolites in a single scan session, making it possible to measure both levels and intracellular microenvironments of brain chemicals in clinical MR spectroscopy studies. Magn Reson Med 78:2072-2081, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Li An
- National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, USA
| | - Shizhe Li
- National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, USA
| | - Jun Shen
- National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
21
|
Wu M, Fang L, Ray CE, Kumar A, Yang S. Adaptively Optimized Combination (AOC) of Phased-Array MR Spectroscopy Data in the Presence of Correlated Noise: Compared with Noise-Decorrelated or Whitened Methods. Magn Reson Med 2016; 78:848-859. [PMID: 27873353 DOI: 10.1002/mrm.26504] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2016] [Revised: 09/02/2016] [Accepted: 09/18/2016] [Indexed: 01/13/2023]
Abstract
PURPOSE A method for adaptively optimized combination (AOC) of MR spectroscopic data from a coil array was recently introduced. The superior performance of the AOC method is evident when compared with the methods that assume uncorrelated noise between coil elements. However, it is unclear whether the AOC method represents the most optimal combination in the presence of correlated noise, when compared with the noise-decorrelated or whitened methods that specifically tackle the correlated noise between coil elements. METHODS A new, unified theoretical framework was developed to illustrate the relationship between the AOC method and three noise-decorrelated or whitened methods, namely, noise-decorrelated combination (nd-comb), whitened singular value decomposition (WSVD), and improved WSVD (WSVD+Apod). Simulation-based comparisons and in vivo human brain experiments on a 3 Tesla (T) MRI scanner were performed using an 8-channel phased-array head coil. RESULTS Compared with the noise-decorrelated or whitened methods, the AOC method consistently yielded the best combination in terms of the robustness against noise and maintaining the combined spectrum from distortion, and the superior performance was most evident at a low signal-to-noise ratio (SNR). CONCLUSION The AOC method represents the theoretical optimal combination in the presence of correlated noise between coil elements, whereas the three noise-decorrelated or whitened methods are asymptotically optimal. Magn Reson Med 78:848-859, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Minjie Wu
- Department of Psychiatry, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Liang Fang
- Department of Psychiatry, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Charles E Ray
- Department of Radiology, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Anand Kumar
- Department of Psychiatry, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Shaolin Yang
- Department of Psychiatry, University of Illinois at Chicago, Chicago, Illinois, USA.,Department of Radiology, University of Illinois at Chicago, Chicago, Illinois, USA.,Department of Bioengineering, University of Illinois at Chicago, Chicago, Illinois, USA
| |
Collapse
|
22
|
Rodgers CT, Robson MD. Coil combination for receive array spectroscopy: Are data-driven methods superior to methods using computed field maps? Magn Reson Med 2016; 75:473-87. [PMID: 25820303 PMCID: PMC4744755 DOI: 10.1002/mrm.25618] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2014] [Revised: 12/01/2014] [Accepted: 12/22/2014] [Indexed: 11/12/2022]
Abstract
PURPOSE Combining spectra from receive arrays, particularly X-nuclear spectra with low signal-to-noise ratios (SNRs), is challenging. We test whether data-driven combination methods are better than using computed coil sensitivities. THEORY Several combination algorithms are recast into the notation of Roemer's classic formula, showing that they differ primarily in their estimation of coil receive sensitivities. This viewpoint reveals two extensions of the whitened singular-value decomposition (WSVD) algorithm, using temporal or temporal + spatial apodization to improve the coil sensitivities, and thus the combined spectral SNR. METHODS Radiofrequency fields from an array were simulated and used to make synthetic spectra. These were combined with 10 algorithms. The combined spectra were then assessed in terms of their SNR. Validation used phantoms and cardiac (31) P spectra from five subjects at 3T. RESULTS Combined spectral SNRs from simulations, phantoms, and humans showed the same trends. In phantoms, the combined SNR using computed coil sensitivities was lower than with WSVD combination whenever the WSVD SNR was >14 (or >11 with temporal apodization, or >9 with temporal + spatial apodization). These new apodized WSVD methods gave higher SNRs than other data-driven methods. CONCLUSION In the human torso, at frequencies ≥49 MHz, data-driven combination is preferable to using computed coil sensitivities. Magn Reson, 2015. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. Magn Reson Med 75:473-487, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Christopher T. Rodgers
- Oxford Centre for Clinical Magnetic Resonance ResearchUniversity of Oxford, John Radcliffe HospitalOxfordUnited Kingdom
| | - Matthew D. Robson
- Oxford Centre for Clinical Magnetic Resonance ResearchUniversity of Oxford, John Radcliffe HospitalOxfordUnited Kingdom
| |
Collapse
|
23
|
Fang X, Bian Y, Wang L. Clinical application of magnetic resonance spectroscopy in diagnosis of pancreatic cancer. Shijie Huaren Xiaohua Zazhi 2016; 24:368-374. [DOI: 10.11569/wcjd.v24.i3.368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Pancreatic cancer (PC) is one of the most frequent malignant tumors of the digestive system, which is difficultly detected and highly aggressive. More than 80% of patients with PC present with advanced disease that is incurable by surgery. Thus, early diagnosis and surgery before frank invasion occurs are critical for improving PC patients' outcomes. Magnetic resonance spectroscopy (MRS) is conducive to screening, early diagnosis and differential diagnosis of PC. Nowadays, MRS is preeminently a tool for nondestructive chemical analysis and metabolic profiling. MRS is expected to be a sensitive and accurate method for PC diagnosis and differential diagnosis, for tracking tumor change and for assessing treatment response.
Collapse
|
24
|
Lally N, An L, Banerjee D, Niciu MJ, Luckenbaugh DA, Richards EM, Roiser JP, Shen J, Zarate CA, Nugent AC. Reliability of 7T (1) H-MRS measured human prefrontal cortex glutamate, glutamine, and glutathione signals using an adapted echo time optimized PRESS sequence: A between- and within-sessions investigation. J Magn Reson Imaging 2016; 43:88-98. [PMID: 26059603 PMCID: PMC4671833 DOI: 10.1002/jmri.24970] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2015] [Accepted: 05/22/2015] [Indexed: 12/12/2022] Open
Abstract
PURPOSE To ascertain the mechanisms of neuropsychiatric illnesses and their treatment, accurate and reliable imaging techniques are required; proton magnetic resonance spectroscopy ((1) H-MRS) can noninvasively measure glutamatergic function. Evidence suggests that aberrant glutamatergic signaling plays a role in numerous psychopathologies. Until recently, overlapping glutamatergic signals (glutamate, glutamine, and glutathione) could not easily be separated. However, the advent of novel pulse sequences and higher field magnetic resonance imaging (MRI) allows more precise resolution of overlapping glutamatergic signals, although the question of signal reliability remains undetermined. MATERIALS AND METHODS At 7T MR, we acquired (1) H-MRS data from the medial pregenual anterior cingulate cortex of healthy volunteers (n = 26) twice on two separate days. An adapted echo time optimized point-resolved spectroscopy sequence, modified with the addition of a J-suppression pulse to attenuate N-acetyl-aspartate multiplet signals at 2.49 ppm, was used to excite and acquire the spectra. In-house software was used to model glutamate, glutamine, and glutathione, among other metabolites, referenced to creatine. Intraclass correlation coefficients (ICCs) were computed for within- and between-session measurements. RESULTS Within-session measurements of glutamate, glutamine, and glutathione were on average reliable (ICCs ≥0.7). As anticipated, ICCs for between-session values of glutamate, glutamine, and glutathione were slightly lower but nevertheless reliable (ICC >0.62). A negative correlation was observed between glutathione concentration and age (r(24) = -0.37; P < 0.05), and a gender effect was noted on glutamine and glutathione. CONCLUSION The adapted sequence provides good reliability to measure glutamate, glutamine, and glutathione signals.
Collapse
Affiliation(s)
- Níall Lally
- Experimental Therapeutics and Pathophysiology Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, USA
- Institute of Cognitive Neuroscience, University College London, Alexandra House, 17 Queen Square, London, WC1N 3AR, UK
| | - Li An
- Magnetic Resonance Spectroscopy Core Facility, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, USA
| | - Dipavo Banerjee
- Experimental Therapeutics and Pathophysiology Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, USA
| | - Mark J. Niciu
- Experimental Therapeutics and Pathophysiology Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, USA
| | - David A. Luckenbaugh
- Experimental Therapeutics and Pathophysiology Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, USA
| | - Erica M. Richards
- Experimental Therapeutics and Pathophysiology Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, USA
| | - Jonathan P Roiser
- Institute of Cognitive Neuroscience, University College London, Alexandra House, 17 Queen Square, London, WC1N 3AR, UK
| | - Jun Shen
- Magnetic Resonance Spectroscopy Core Facility, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, USA
| | - Carlos A. Zarate
- Experimental Therapeutics and Pathophysiology Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, USA
| | - Allison C. Nugent
- Experimental Therapeutics and Pathophysiology Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
25
|
Li N, An L, Shen J. Spectral fitting using basis set modified by measured B0 field distribution. NMR IN BIOMEDICINE 2015; 28:1707-1715. [PMID: 26503305 PMCID: PMC4715526 DOI: 10.1002/nbm.3430] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2015] [Revised: 08/18/2015] [Accepted: 09/11/2015] [Indexed: 05/30/2023]
Abstract
This study sought to demonstrate and evaluate a novel spectral fitting method to improve quantification accuracy in the presence of large magnetic field distortion, especially with high fields. MRS experiments were performed using a point-resolved spectroscopy (PRESS)-type sequence at 7 T. A double-echo gradient echo (GRE) sequence was used to acquire B0 maps following MRS experiments. The basis set was modified based on the measured B0 distribution within the MRS voxel. Quantification results were obtained after fitting the measured MRS data using the modified basis set. The proposed method was validated using numerical Monte Carlo simulations, phantom measurements, and comparison of occipital lobe MRS measurements under homogeneous and inhomogeneous magnetic field conditions. In vivo results acquired from voxels placed in thalamus and prefrontal cortex regions close to the frontal sinus agreed well with published values. Instead of noise-amplifying complex division, the proposed method treats field variations as part of the signal model, thereby avoiding inherent statistical bias associated with regularization. Simulations and experiments showed that the proposed approach reliably quantified results in the presence of relatively large magnetic field distortion. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
Collapse
Affiliation(s)
- Ningzhi Li
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, MD, USA
| | - Li An
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, MD, USA
| | - Jun Shen
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, MD, USA
| |
Collapse
|
26
|
Abdoli A, Maudsley AA. Phased-array combination for MR spectroscopic imaging using a water reference. Magn Reson Med 2015; 76:733-41. [PMID: 26413752 DOI: 10.1002/mrm.25992] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2015] [Revised: 08/04/2015] [Accepted: 08/27/2015] [Indexed: 12/29/2022]
Abstract
PURPOSE To evaluate methods for multichannel combination of three-dimensional MR spectroscopic imaging (MRSI) data with a focus on using information from a water-reference spectroscopic image. METHODS Volumetric MRSI data were acquired for a phantom and for human brain using 8- and 32-channel detection. Acquisition included a water-reference dataset that was used to determine the weights for several multichannel combination methods. Results were compared using the signal-to-noise ratio (SNR) of the N-acetylaspartate resonance. RESULTS Performance of all methods was very similar for the phantom study, with the whitened singular value decomposition (WSVD) and signal magnitude (S) weighting combination having a small advantage. For in vivo studies, the S weighting, SNR weighting and signal to noise squared (S/N(2) ) weighting were the three best methods and performed similarly. Example spectra and SNR maps indicated that the SVD and WSVD methods tend to fail for voxels at the outer edges of the brain that include strong lipid signal contributions. CONCLUSION For data combination of MRSI data using water-reference information, the S/N(2) weighting, SNR and S weighting were the best methods in terms of spectral quality SNR. These methods are also computationally efficient and easy to implement. Magn Reson Med 76:733-741, 2016. © 2015 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Abas Abdoli
- Department of Radiology, University of Miami School of Medicine, Miami, Florida, USA
| | - Andrew A Maudsley
- Department of Radiology, University of Miami School of Medicine, Miami, Florida, USA
| |
Collapse
|
27
|
An L, Li S, Wood ET, Reich DS, Shen J. N-acetyl-aspartyl-glutamate detection in the human brain at 7 Tesla by echo time optimization and improved Wiener filtering. Magn Reson Med 2014; 72:903-12. [PMID: 24243344 PMCID: PMC4020995 DOI: 10.1002/mrm.25007] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2013] [Revised: 09/27/2013] [Accepted: 09/30/2013] [Indexed: 11/09/2022]
Abstract
PURPOSE To report enhanced signal detection for measuring N-acetyl-aspartyl-glutamate (NAAG) in the human brain at 7 Tesla by echo time (TE) -optimized point-resolved spectroscopy (PRESS) and improved Wiener filtering. METHODS Using a highly efficient in-house developed numerical simulation program, a PRESS sequence with (TE1 , TE2 ) = (26, 72) ms was found to maximize the NAAG signals relative to the overlapping Glu signals. A new Wiener filtering water reference deconvolution method was developed to reduce broadening and distortions of metabolite peaks caused by B0 inhomogeneity and eddy currents. RESULTS Monte Carlo simulation results demonstrated that the new Wiener filtering method offered higher spectral resolution, reduced spectral artifacts, and higher accuracy in NAAG quantification compared with the original Wiener filtering method. In vivo spectra and point spread functions of signal distortion confirmed that the new Wiener filtering method lead to improved spectral resolution and reduced spectral artifacts. CONCLUSION TE-optimized PRESS in combination with a new Wiener filtering method made it possible to fully use both the NAAG singlet signal at 2.05 ppm and the NAAG multiplet signal at 2.18 ppm in the quantification of NAAG. A more accurate characterization of lineshape distortion for Wiener filtering needs B0 field maps and segmented anatomical images to exclude contribution from cerebral spinal fluid.
Collapse
Affiliation(s)
- Li An
- National Institute of Mental Health, National Institutes of Health, Bethesda, MD
| | - Shizhe Li
- National Institute of Mental Health, National Institutes of Health, Bethesda, MD
| | - Emily T Wood
- NeuroImmunology Branch (NINDS), National Institutes of Health, Bethesda, MD
- Department of Neuroscience, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Daniel S Reich
- NeuroImmunology Branch (NINDS), National Institutes of Health, Bethesda, MD
| | - Jun Shen
- National Institute of Mental Health, National Institutes of Health, Bethesda, MD
| |
Collapse
|
28
|
An L, Li S, Murdoch JB, Araneta MF, Johnson C, Shen J. Detection of glutamate, glutamine, and glutathione by radiofrequency suppression and echo time optimization at 7 tesla. Magn Reson Med 2014; 73:451-8. [DOI: 10.1002/mrm.25150] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2013] [Revised: 01/06/2014] [Accepted: 01/08/2014] [Indexed: 11/09/2022]
Affiliation(s)
- Li An
- National Institute of Mental Health, National Institutes of Health; Bethesda Maryland USA
| | - Shizhe Li
- National Institute of Mental Health, National Institutes of Health; Bethesda Maryland USA
| | - James B. Murdoch
- Toshiba Medical Research Institute USA; Mayfield Village Ohio USA
| | - Maria Ferraris Araneta
- National Institute of Mental Health, National Institutes of Health; Bethesda Maryland USA
| | - Christopher Johnson
- National Institute of Mental Health, National Institutes of Health; Bethesda Maryland USA
| | - Jun Shen
- National Institute of Mental Health, National Institutes of Health; Bethesda Maryland USA
| |
Collapse
|
29
|
Harry H, Kan HE. Quantitative proton MR techniques for measuring fat. NMR IN BIOMEDICINE 2013; 26:1609-29. [PMID: 24123229 PMCID: PMC4001818 DOI: 10.1002/nbm.3025] [Citation(s) in RCA: 91] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2013] [Revised: 07/13/2013] [Accepted: 08/19/2013] [Indexed: 05/09/2023]
Abstract
Accurate, precise and reliable techniques for the quantification of body and organ fat distributions are important tools in physiology research. They are critically needed in studies of obesity and diseases involving excess fat accumulation. Proton MR methods address this need by providing an array of relaxometry-based (T1, T2) and chemical shift-based approaches. These techniques can generate informative visualizations of regional and whole-body fat distributions, yield measurements of fat volumes within specific body depots and quantify fat accumulation in abdominal organs and muscles. MR methods are commonly used to investigate the role of fat in nutrition and metabolism, to measure the efficacy of short- and long-term dietary and exercise interventions, to study the implications of fat in organ steatosis and muscular dystrophies and to elucidate pathophysiological mechanisms in the context of obesity and its comorbidities. The purpose of this review is to provide a summary of mainstream MR strategies for fat quantification. The article succinctly describes the principles that differentiate water and fat proton signals, summarizes the advantages and limitations of various techniques and offers a few illustrative examples. The article also highlights recent efforts in the MR of brown adipose tissue and concludes by briefly discussing some future research directions.
Collapse
Affiliation(s)
- Houchun Harry
- Corresponding Author Houchun Harry Hu, PhD Children's Hospital Los Angeles University of Southern California 4650 Sunset Boulevard Department of Radiology, MS #81 Los Angeles, California, USA. 90027 , Office: +1 (323) 361-2688 Fax: +1 (323) 361-1510
| | - Hermien E. Kan
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|