Chen C, Chandrasekaran P, Liu Y, Simonetti OP, Tong M, Ahmad R. Ensuring respiratory phase consistency to improve cardiac function quantification in real-time CMR.
Magn Reson Med 2022;
87:1595-1604. [PMID:
34719067 PMCID:
PMC8776600 DOI:
10.1002/mrm.29064]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Revised: 09/16/2021] [Accepted: 10/13/2021] [Indexed: 11/09/2022]
Abstract
PURPOSE
To develop an automatic method for selecting heartbeats with consistent respiratory phase to improve accuracy of cardiac function quantification in real-time (RT) cardiac MRI.
METHODS
The respiratory signal is extracted by a principal component analysis method from RT cine images. Then, a two-step procedure is used to determine the directionality (sign) of the respiratory signal. With the motion in a manually selected region-of-interest as a reference, the quality of the extracted respiratory signal is assessed using multislice RT cine data from 11 volunteers and 10 patients. In addition, the impact of selecting heartbeats with consistent respiratory phase on the cardiac function quantification is evaluated.
RESULTS
The extracted respiratory signal using the proposed method exhibits a high, positive correlation with the reference in all cases and is more robust compared to a recently proposed method. Also, for right ventricular function quantification, selecting heartbeats at expiratory position improves agreement between RT cine and breath-held reference.
CONCLUSION
The proposed method enables fully automatic extraction and directionality determinations of respiratory signal from RT cardiac cine images, allowing accurate cardiac function quantification.