1
|
Thompson RB, Sherrington R, Beaulieu C, Kirkham A, Paterson DI, Seres P, Grenier J. Reference Values for Water-Specific T1 of the Liver at 3 T: T2*-Compensation and the Confounding Effects of Fat. J Magn Reson Imaging 2024; 60:2063-2075. [PMID: 38305588 DOI: 10.1002/jmri.29262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 01/13/2024] [Accepted: 01/16/2024] [Indexed: 02/03/2024] Open
Abstract
BACKGROUND T1 mapping of the liver is confounded by the presence of fat. Multiparametric T1 mapping combines fat-water separation with T1-weighting to enable imaging of water-specific T1 (T1Water), proton density fat fraction (PDFF), and T2* values. However, normative T1Water values in the liver and its dependence on age/sex is unknown. PURPOSE Determine normative values for T1Water in the liver with comparison to MOLLI and evaluate a T2*-compensation approach to reduce T1 variability. STUDY TYPE Prospective observational; phantoms. POPULATIONS One hundred twenty-four controls (56 male, 18-75 years), 50 patients at-risk for liver disease (18 male, 30-76 years). FIELD STRENGTH/SEQUENCE 2.89 T; Saturation-recovery chemical-shift encoded T1 Mapping (SR-CSE); MOLLI. ASSESSMENT SR-CSE provided T1Water measurements, PDFF and T2* values in the liver across three slices in 6 seconds. These were compared with MOLLI T1 values. A new T2*-compensation approach to reduce T1 variability was evaluated test/re-test reproducibility. STATISTICAL TESTS Linear regression, ANCOVA, t-test, Bland and Altman, intraclass correlation coefficient (ICC). P < 0.05 was considered statistically significant. RESULTS Liver T1 values were significantly higher in healthy females (F) than males (M) for both SR-CSE (F-973 ± 78 msec, M-930 ± 72 msec) and MOLLI (F-802 ± 55 msec, M-759 ± 69 msec). T1 values were negatively correlated with age, with similar sex- and age-dependencies observed in T2*. The T2*-compensation model reduced the variability of T1 values by half and removed sex- and age-differences (SR-CSE: F-946 ± 36 msec, M-941 ± 43 msec; MOLLI: F-775 ± 35 msec, M-770 ± 35 msec). At-risk participants had elevated PDFF and T1 values, which became more distinct from the healthy cohort after T2*-compensation. MOLLI systematically underestimated liver T1 values by ~170 msec with an additional positive T1-bias from fat content (~11 msec/1% in PDFF). Reproducibility ICC values were ≥0.96 for all parameters. DATA CONCLUSION Liver T1Water values were lower in males and decreased with age, as observed for SR-CSE and MOLLI acquisitions. MOLLI underestimated liver T1 with an additional large positive fat-modulated T1 bias. T2*-compensation removed sex- and age-dependence in liver T1, reduced the range of healthy values and increased T1 group differences between healthy and at-risk groups. EVIDENCE LEVEL 2 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Richard B Thompson
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada
| | - Rachel Sherrington
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada
| | - Christian Beaulieu
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada
| | - Amy Kirkham
- Faculty of Kinesiology & Physical Education, University of Toronto, Toronto, Ontario, Canada
| | - David I Paterson
- Division of Cardiology, University of Ottawa Heart Institute, Ottawa, Ontario, Canada
| | - Peter Seres
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada
| | - Justin Grenier
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
2
|
Muslu Y, Tamada D, Roberts NT, Cashen TA, Mandava S, Kecskemeti SR, Hernando D, Reeder SB. Free-breathing, fat-corrected T 1 mapping of the liver with stack-of-stars MRI, and joint estimation of T 1, PDFF, R 2 * , and B 1 + . Magn Reson Med 2024; 92:1913-1932. [PMID: 38923009 DOI: 10.1002/mrm.30182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Revised: 05/03/2024] [Accepted: 05/16/2024] [Indexed: 06/28/2024]
Abstract
PURPOSE Quantitative T1 mapping has the potential to replace biopsy for noninvasive diagnosis and quantitative staging of chronic liver disease. Conventional T1 mapping methods are confounded by fat andB 1 + $$ {B}_1^{+} $$ inhomogeneities, resulting in unreliable T1 estimations. Furthermore, these methods trade off spatial resolution and volumetric coverage for shorter acquisitions with only a few images obtained within a breath-hold. This work proposes a novel, volumetric (3D), free-breathing T1 mapping method to account for multiple confounding factors in a single acquisition. THEORY AND METHODS Free-breathing, confounder-corrected T1 mapping was achieved through the combination of non-Cartesian imaging, magnetization preparation, chemical shift encoding, and a variable flip angle acquisition. A subspace-constrained, locally low-rank image reconstruction algorithm was employed for image reconstruction. The accuracy of the proposed method was evaluated through numerical simulations and phantom experiments with a T1/proton density fat fraction phantom at 3.0 T. Further, the feasibility of the proposed method was investigated through contrast-enhanced imaging in healthy volunteers, also at 3.0 T. RESULTS The method showed excellent agreement with reference measurements in phantoms across a wide range of T1 values (200 to 1000 ms, slope = 0.998 (95% confidence interval (CI) [0.963 to 1.035]), intercept = 27.1 ms (95% CI [0.4 54.6]), r2 = 0.996), and a high level of repeatability. In vivo imaging studies demonstrated moderate agreement (slope = 1.099 (95% CI [1.067 to 1.132]), intercept = -96.3 ms (95% CI [-82.1 to -110.5]), r2 = 0.981) compared to saturation recovery-based T1 maps. CONCLUSION The proposed method produces whole-liver, confounder-corrected T1 maps through simultaneous estimation of T1, proton density fat fraction, andB 1 + $$ {B}_1^{+} $$ in a single, free-breathing acquisition and has excellent agreement with reference measurements in phantoms.
Collapse
Affiliation(s)
- Yavuz Muslu
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Daiki Tamada
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | | | | | | | | | - Diego Hernando
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Scott B Reeder
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Emergency Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA
| |
Collapse
|
3
|
Alkhouri N, Beyer C, Shumbayawonda E, Andersson A, Yale K, Rolph T, Chung RT, Vuppalanchi R, Cusi K, Loomba R, Pansini M, Dennis A. Decreases in cT1 and liver fat content reflect treatment-induced histological improvements in MASH. J Hepatol 2024:S0168-8278(24)02559-5. [PMID: 39326675 DOI: 10.1016/j.jhep.2024.08.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 08/26/2024] [Accepted: 08/29/2024] [Indexed: 09/28/2024]
Abstract
BACKGROUND & AIMS MRI biomarkers of liver disease are robust and reproducible alternatives to liver biopsy. Emerging data suggest that absolute reduction in iron corrected T1 (cT1) of ≥ 80 ms and relative reduction in liver fat content of 30% reflect histological improvement. We aimed to validate the associations of changes to these noninvasive biomarkers with histological improvement, specifically the resolution of steatohepatitis. METHODS A retrospective analysis of participants from three interventional clinical trials who underwent multiparametric MRI to measure liver cT1 and liver fat content (LFC) (LiverMultiScan) alongside biopsies at baseline and end of study. Responders were defined as those achieving resolution of steatohepatitis with no worsening in fibrosis. Differences in the magnitude of change in cT1 and LFC between responders and non-responders was assessed. RESULTS Individual patient data from 150 participants were included. There was a significant decrease in liver cT1 (-119 ms vs. -49 ms) and liver fat content (-65% vs. -29%) in responders compared to non-responders (P < .001) respectively. The diagnostic accuracy to identify responders was 0.72 (AUC) for both. The Youden's index for cT1 to separate responders from non-responders was -82 ms and for liver fat was a 58% relative reduction. Those achieving a ≥ 80 ms reduction in cT1 were 5-times more likely to achieve histological response (sens 0.68; spec 0.70). Those achieving a 30% relative reduction in liver fat were ∼4 times more likely to achieve a histological response (sens 0.77; spec 0.53). CONCLUSIONS These results, from three combined drug trials, demonstrate that changes in multiparametric MRI markers of liver health (cT1 and PDFF) can predict histological response for steatohepatitis following therapeutic intervention. IMPACT AND IMPLICATIONS There is great interest in identifying suitable biomarkers that can be used to replace liver biopsy, or to identify those patients who would benefit from one, in both the clinical management of MASH and in drug development. We investigated the utility of two MRI-derived non-invasive tests, iron corrected T1 mapping (cT1) and liver fat content from proton density fat fraction (PDFF), to predict histological improvement in patients who had undergone experimental treatment for MASH. Using data from 150 people who participated in one of three clinical trials, we observed that a reduction in cT1 by over 80 ms and a relative reduction in PDFF of over 58% were the optimal thresholds for change that predicted resolution of steatohepatitis. PDFF as a marker of liver fat, and cT1 as a specific measure of liver disease activity, are both effective at identifying those who are likely responding to drug interventions and experiencing improvements in overall liver health. CLINICAL TRIAL NUMBER(S) NCT02443116, NCT03976401, NCT03551522.
Collapse
Affiliation(s)
| | | | | | | | - Kitty Yale
- Akero Therapeutics Inc., South San Francisco, California, USA
| | - Timothy Rolph
- Akero Therapeutics Inc., South San Francisco, California, USA
| | - Raymond T Chung
- Liver Center, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Raj Vuppalanchi
- Division of Gastroenterology and Hepatology, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Kenneth Cusi
- Division of Endocrinology, Diabetes and Metabolism, University of Florida, Gainesville, FL, USA
| | - Rohit Loomba
- MASLD Research Center, University of California at San Diego, La Jolla, CA, USA
| | - Michele Pansini
- Clinica Di Radiologia EOC, Istituto Di Imaging Della Svizzera Italiana (IIMSI), Ente Ospedaliero Cantonale, Via Tesserete 46, 6900, Lugano, Switzerland; John Radcliffe Hospital, Oxford University Hospitals NHS Foundation Trust, OX3 0AG, Oxford, UK
| | | |
Collapse
|
4
|
Serai SD, Robson MD, Tirkes T, Trout AT. T 1 Mapping of the Abdomen, From the AJR "How We Do It" Special Series. AJR Am J Roentgenol 2024. [PMID: 39194308 DOI: 10.2214/ajr.24.31643] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/29/2024]
Abstract
By exploiting different tissues' characteristic T1 relaxation times, T1-weighted images help distinguish normal and abnormal tissues, aiding assessment of diffuse and local pathologies. However, such images do not provide quantitative T1 values. Advances in abdominal MRI techniques have enabled measurement of abdominal organs' T1 relaxation times, which can be used to create color-coded quantitative maps. T1 mapping is sensitive to tissue microenvironments including inflammation and fibrosis and has received substantial interest for noninvasive imaging of abdominal organ pathology. In particular, quantitative mapping provides a powerful tool for evaluation of diffuse disease by making apparent changes in T1 occurring across organs that may otherwise be difficult to identify. Quantitative measurement also facilitates sensitive monitoring of longitudinal T1 changes. Increased T1 in liver helps to predict parenchymal fibro-inflammation, in pancreas is associated with reduced exocrine function from chronic or autoimmune pancreatitis, and in kidney is associated with impaired renal function and aids diagnosis of chronic kidney disease. In this review, we describe the acquisition, postprocessing, and analysis of T1 maps in the abdomen and explore applications in liver, spleen, pancreas, and kidney. We highlight practical aspects of implementation and standardization, technical pitfalls and confounding factors, and areas of likely greatest clinical impact.
Collapse
Affiliation(s)
- Suraj D Serai
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | | | - Temel Tirkes
- Department of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Andrew T Trout
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| |
Collapse
|
5
|
Manhard MK, Kilpattu Ramaniharan A, Tkach JA, Trout AT, Dillman JR, Pednekar AS. Simultaneous Multiparameter Mapping of the Liver in a Single Breath-Hold or Respiratory-Triggered Acquisition Using Multi-Inversion Spin and Gradient Echo MRI. J Magn Reson Imaging 2024. [PMID: 39192381 DOI: 10.1002/jmri.29584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2024] [Revised: 08/06/2024] [Accepted: 08/07/2024] [Indexed: 08/29/2024] Open
Abstract
BACKGROUND Quantitative parametric mapping is an increasingly important tool for noninvasive assessment of chronic liver disease. Conventional parametric mapping techniques require multiple breath-held acquisitions and provide limited anatomic coverage. PURPOSE To investigate a multi-inversion spin and gradient echo (MI-SAGE) technique for simultaneous estimation of T1, T2, and T2* of the liver. STUDY TYPE Prospective. SUBJECTS Sixteen research participants, both adult and pediatric (age 17.5 ± 4.6 years, eight male), with and without known liver disease (seven asymptomatic healthy controls, two fibrotic liver disease, five steatotic liver disease, and two fibrotic and steatotic liver disease). FIELD STRENGTH/SEQUENCE 1.5 T, single breath-hold and respiratory triggered MI-SAGE, breath-hold modified Look-Locker inversion recovery (MOLLI, T1 mapping), breath-hold gradient and spin echo (GRASE, T2 mapping), and multiple gradient echo (mGRE, T2* mapping) sequences. ASSESSMENT Agreement between hepatic T1, T2, and T2* estimated using MI-SAGE and conventional parametric mapping sequences was evaluated. Repeatability and reproducibility of MI-SAGE were evaluated using a same-session acquisition and second-session acquisition. STATISTICAL TESTS Bland-Altman analysis with bias assessment and limits of agreement (LOA) and intraclass correlation coefficients (ICC). RESULTS Hepatic T1, T2, and T2* estimates obtained using the MI-SAGE technique had mean biases of 72 (LOA: -22 to 166) msec, -3 (LOA: -10 to 5) msec, and 2 (LOA: -5 to 8) msec (single breath-hold) and 36 (LOA: -43 to 120) msec, -3 (LOA: -17 to 11) msec, and 4 (LOA: -3 to 11) msec (respiratory triggered), respectively, in comparison to conventional acquisitions using MOLLI, GRASE, and mGRE. All MI-SAGE estimates had strong repeatability and reproducibility (ICC > 0.72). DATA CONCLUSION Hepatic T1, T2, and T2* estimates obtained using an MI-SAGE technique were comparable to conventional methods, although there was a 12%/6% for breath-hold/respiratory triggered underestimation of T1 values compared to MOLLI. Both respiratory triggered and breath-hold MI-SAGE parameter maps demonstrated strong repeatability and reproducibility. LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Mary Kate Manhard
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
| | | | - Jean A Tkach
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
| | - Andrew T Trout
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
| | - Jonathan R Dillman
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
| | - Amol S Pednekar
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
| |
Collapse
|
6
|
Xie S, Chen M, Chen C, Zhao Y, Qin J, Qiu C, Zhu J, Nickel MD, Kuehn B, Shen W. T1 mapping combined with arterial spin labeling MRI to identify renal injury in patients with liver cirrhosis. Front Endocrinol (Lausanne) 2024; 15:1363797. [PMID: 39184137 PMCID: PMC11341387 DOI: 10.3389/fendo.2024.1363797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Accepted: 07/08/2024] [Indexed: 08/27/2024] Open
Abstract
Purpose We investigated the capability and imaging criteria of T1 mapping and arterial spin labeling (ASL) MRI to identify renal injury in patients with liver cirrhosis. Methods We recruited 27 patients with cirrhosis and normal renal function (cirrhosis-NR), 10 with cirrhosis and renal dysfunction (cirrhosis-RD) and 23 normal controls (NCs). All participants were examined via renal T1 mapping and ASL imaging. Renal blood flow (RBF) derived from ASL was measured from the renal cortex, and T1 values were measured from the renal parenchyma (cortex and medulla). MRI parameters were compared between groups. Diagnostic performances for detecting renal impairment were statistically analyzed. Results Cortical T1 (cT1) and medullary T1 (mT1) were significantly lower in the NCs than in the cirrhosis-NR group. The cortical RBF showed no significant changes between the NCs and cirrhosis-NR group but was markedly decreased in the cirrhosis-RD group. The areas under the curve (AUCs) for discriminating cirrhosis-NR from NCs were 0.883 and 0.826 by cT1 and mT1, respectively. Cortical RBF identified cirrhosis-RD with AUC of 0.978, and correlated with serum creatinine (r = -0.334) and the estimated glomerular filtration rate (r = 0.483). A classification and regression tree based on cortical RBF and cT1 achieved 85% accuracy in detecting renal impairment in the cirrhosis. Conclusion Renal T1 values might be sensitive predictors of early renal impairment in patients with cirrhosis-NR. RBF enabled quantifying renal perfusion impairment in patients with cirrhosis-RD. The diagnostic algorithm based on cortical RBF and T1 values allowed detecting renal injury during cirrhosis.
Collapse
Affiliation(s)
- Shuangshuang Xie
- Radiology Department, Tianjin First Central Hospital, Tianjin Institute of Imaging Medicine, School of Medicine, Nankai University, Tianjin, China
| | - Mengyao Chen
- Radiology Department, Tianjin First Central Hospital, Tianjin Institute of Imaging Medicine, School of Medicine, Nankai University, Tianjin, China
| | - Chiyi Chen
- Liver Surgery Department, Tianjin First Central Hospital, School of Medicine, Nankai University, Tianjin, China
| | - Yumeng Zhao
- Radiology Department, Tianjin First Central Hospital, Tianjin Institute of Imaging Medicine, School of Medicine, Nankai University, Tianjin, China
| | - Jiaming Qin
- Radiology Department, Tianjin First Central Hospital, Tianjin Institute of Imaging Medicine, School of Medicine, Nankai University, Tianjin, China
| | - Caixin Qiu
- Radiology Department, Tianjin First Central Hospital, Tianjin Institute of Imaging Medicine, School of Medicine, Nankai University, Tianjin, China
| | - Jinxia Zhu
- MR Research Collaboration, Siemens Healthineers, Beijing, China
| | | | - Bernd Kuehn
- MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany
| | - Wen Shen
- Radiology Department, Tianjin First Central Hospital, Tianjin Institute of Imaging Medicine, School of Medicine, Nankai University, Tianjin, China
| |
Collapse
|
7
|
Stelter J, Weiss K, Steinhelfer L, Spieker V, Huaroc Moquillaza E, Zhang W, Makowski MR, Schnabel JA, Kainz B, Braren RF, Karampinos DC. Simultaneous whole-liver water T 1 $$ {\mathrm{T}}_1 $$ and T 2 $$ {\mathrm{T}}_2 $$ mapping with isotropic resolution during free-breathing. NMR IN BIOMEDICINE 2024:e5216. [PMID: 39099162 DOI: 10.1002/nbm.5216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 06/03/2024] [Accepted: 06/18/2024] [Indexed: 08/06/2024]
Abstract
PURPOSE To develop and validate a data acquisition scheme combined with a motion-resolved reconstruction and dictionary-matching-based parameter estimation to enable free-breathing isotropic resolution self-navigated whole-liver simultaneous water-specificT 1 $$ {\mathrm{T}}_1 $$ (wT 1 $$ {\mathrm{wT}}_1 $$ ) andT 2 $$ {\mathrm{T}}_2 $$ (wT 2 $$ {\mathrm{wT}}_2 $$ ) mapping for the characterization of diffuse and oncological liver diseases. METHODS The proposed data acquisition consists of a magnetization preparation pulse and a two-echo gradient echo readout with a radial stack-of-stars trajectory, repeated with different preparations to achieve differentT 1 $$ {\mathrm{T}}_1 $$ andT 2 $$ {\mathrm{T}}_2 $$ contrasts in a fixed acquisition time of 6 min. Regularized reconstruction was performed using self-navigation to account for motion during the free-breathing acquisition, followed by water-fat separation. Bloch simulations of the sequence were applied to optimize the sequence timing forB 1 $$ {B}_1 $$ insensitivity at 3 T, to correct for relaxation-induced blurring, and to mapT 1 $$ {\mathrm{T}}_1 $$ andT 2 $$ {\mathrm{T}}_2 $$ using a dictionary. The proposed method was validated on a water-fat phantom with varying relaxation properties and in 10 volunteers against imaging and spectroscopy reference values. The performance and robustness of the proposed method were evaluated in five patients with abdominal pathologies. RESULTS Simulations demonstrate goodB 1 $$ {B}_1 $$ insensitivity of the proposed method in measuringT 1 $$ {\mathrm{T}}_1 $$ andT 2 $$ {\mathrm{T}}_2 $$ values. The proposed method produces co-registeredwT 1 $$ {\mathrm{wT}}_1 $$ andwT 2 $$ {\mathrm{wT}}_2 $$ maps with a good agreement with reference methods (phantom:wT 1 = 1 . 02 wT 1,ref - 8 . 93 ms , R 2 = 0 . 991 $$ {\mathrm{wT}}_1=1.02\kern0.1em {\mathrm{wT}}_{1,\mathrm{ref}}-8.93\kern0.1em \mathrm{ms},{R}^2=0.991 $$ ;wT 2 = 1 . 03 wT 2,ref + 0 . 73 ms , R 2 = 0 . 995 $$ {\mathrm{wT}}_2=1.03\kern0.1em {\mathrm{wT}}_{2,\mathrm{ref}}+0.73\kern0.1em \mathrm{ms},{R}^2=0.995 $$ ). The proposedwT 1 $$ {\mathrm{wT}}_1 $$ andwT 2 $$ {\mathrm{wT}}_2 $$ mapping exhibits good repeatability and can be robustly performed in patients with pathologies. CONCLUSIONS The proposed method allows whole-liverwT 1 $$ {\mathrm{wT}}_1 $$ andwT 2 $$ {\mathrm{wT}}_2 $$ quantification with high accuracy at isotropic resolution in a fixed acquisition time during free-breathing.
Collapse
Affiliation(s)
- Jonathan Stelter
- Institute of Diagnostic and Interventional Radiology, School of Medicine and Health, Technical University of Munich, Munich, Germany
| | | | - Lisa Steinhelfer
- Institute of Diagnostic and Interventional Radiology, School of Medicine and Health, Technical University of Munich, Munich, Germany
| | - Veronika Spieker
- Institute of Machine Learning for Biomedical Imaging, Helmholtz Munich, Neuherberg, Germany
- School of Computation, Information and Technology, Technical University of Munich, Munich, Germany
| | - Elizabeth Huaroc Moquillaza
- Institute of Diagnostic and Interventional Radiology, School of Medicine and Health, Technical University of Munich, Munich, Germany
| | - Weitong Zhang
- Department of Computing, Imperial College London, London, United Kingdom
| | - Marcus R Makowski
- Institute of Diagnostic and Interventional Radiology, School of Medicine and Health, Technical University of Munich, Munich, Germany
| | - Julia A Schnabel
- Institute of Machine Learning for Biomedical Imaging, Helmholtz Munich, Neuherberg, Germany
- School of Computation, Information and Technology, Technical University of Munich, Munich, Germany
- School of Biomedical Imaging and Imaging Sciences, King's College London, London, United Kingdom
| | - Bernhard Kainz
- Department of Computing, Imperial College London, London, United Kingdom
- Department Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Rickmer F Braren
- Institute of Diagnostic and Interventional Radiology, School of Medicine and Health, Technical University of Munich, Munich, Germany
| | - Dimitrios C Karampinos
- Institute of Diagnostic and Interventional Radiology, School of Medicine and Health, Technical University of Munich, Munich, Germany
- Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany
- Munich Data Science Institute, Technical University of Munich, Garching, Germany
| |
Collapse
|
8
|
Yang R, Peng H, Pan J, Wan Q, Zou C, Hu F. Native and Gd-EOB-DTPA-Enhanced T1 mapping for Assessment of Liver Fibrosis in NAFLD: Comparative Analysis of Modified Look-Locker Inversion Recovery and Water-specific T1 mapping. Acad Radiol 2024:S1076-6332(24)00443-4. [PMID: 39043516 DOI: 10.1016/j.acra.2024.07.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Revised: 07/03/2024] [Accepted: 07/04/2024] [Indexed: 07/25/2024]
Abstract
RATIONALE AND OBJECTIVES To investigate the diagnostic performance of water-specific T1 mapping for staging liver fibrosis in a non-alcoholic fatty liver disease (NAFLD) rabbit model, in comparison to Modified Look-Locker Inversion recovery (MOLLI) T1 mapping. MATERIALS AND METHODS 60 rabbits were randomly divided into the control group (12 rabbits) and NAFLD model groups (eight rabbits per subgroup) corresponding to different durations of high-fat high cholesterol diet feeding. All rabbits underwent MRI examination including MOLLI T1 mapping and 3D multi-echo variable flip angle (VFAME- GRE) sequences were acquired before and 20 min after the administration of Gd- EOB-DTPA. Histological assessments were performed to evaluate steatosis, inflammation, ballooning, and fibrosis. Statistical analysis included the intraclass correlation coefficient, analysis of variance, spearman correlation, multiple linear regression, and receiver operating characteristic curve. RESULTS A moderate correlation was observed between conventional native T1 and MRI-PDFF (r = -0.513, P < 0.001), as well as between conventional native T1 and liver steatosis grades (r = -0.319, P = 0.016). However, no significant correlation was found between the native wT1 and PDFF (r = 0.137, P = 0.314), or between the native wT1 and steatosis grades (r = 0.106, P = 0.435). In the multiple regression analysis, liver fibrosis, and hepatocellular ballooning were identified as independent factors influencing native wT1 in this study (R2 =0.545, P < 0.05), while steatosis was independently associated with conventional native T1 (R2 =0.321, P < 0.05). The AUC values for native T1, native wT1, HBP T1, and HBP wT1 were 0.549(0.410-0.682), 0.811(0.684-0.903), 0.775(0.644-0.876), and 0.752(0.619-0.858) for F1 or higher, 0.581(0.441-0.711), 0.828(0.704-0.916), 0.832(0.708-0.919), and 0.854(0.734-0.934) for F2 or higher, respectively. CONCLUSION The native wT1 may provide a more reliable assessment of early liver fibrosis in the context of NAFLD compared to conventional native T1.
Collapse
Affiliation(s)
- Ru Yang
- Department of Radiology, The First Affiliated Hospital of Chengdu Medical College, No.278, Baoguang Road, Xindu District, Chengdu, Sichuan, China (R.Y., J.P., F.H.)
| | - Hao Peng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Avenue, Nanshan District, Shenzhen, Guangdong, China (H.P., Q.W., C.Z.)
| | - Jing Pan
- Department of Radiology, The First Affiliated Hospital of Chengdu Medical College, No.278, Baoguang Road, Xindu District, Chengdu, Sichuan, China (R.Y., J.P., F.H.)
| | - Qian Wan
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Avenue, Nanshan District, Shenzhen, Guangdong, China (H.P., Q.W., C.Z.)
| | - Chao Zou
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Avenue, Nanshan District, Shenzhen, Guangdong, China (H.P., Q.W., C.Z.)
| | - Fubi Hu
- Department of Radiology, The First Affiliated Hospital of Chengdu Medical College, No.278, Baoguang Road, Xindu District, Chengdu, Sichuan, China (R.Y., J.P., F.H.).
| |
Collapse
|
9
|
Gjela M, Askeland A, Mellergaard M, Drewes AM, Handberg A, Frøkjær JB. Intra-pancreatic fat deposition and its relation to obesity: a magnetic resonance imaging study. Scand J Gastroenterol 2024; 59:742-748. [PMID: 38557425 DOI: 10.1080/00365521.2024.2333365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Accepted: 03/17/2024] [Indexed: 04/04/2024]
Abstract
OBJECTIVES Intra-pancreatic fat deposition (IPFD) is suspected to be associated with various medical conditions. This study aimed to assess pancreatic fat content in lean and obese individuals, characterize obese individuals with and without IPFD, and explore the underlying mechanisms. MATERIALS AND METHODS Sixty-two obese individuals without diabetes and 35 lean controls underwent magnetic resonance imaging (MRI) using proton density fat fraction (PDFF) maps to evaluate pancreatic and hepatic fat content, and visceral adipose tissue (VAT) content. Pancreatic fibrosis was explored by T1 relaxation time and MR elastography (MRE) measurements. Associations between pancreatic fat, measures of obesity and metabolic syndrome were examined using uni- and multivariate regression analyses. RESULTS Pancreatic PDFF was higher in obese than in lean controls (median 8.0%, interquartile range (6.1;13.3) % vs 2.6(1.7;3.9)%, p < 0.001). Obese individuals with IPFD (PDFF ≥6.2%) had higher waist circumference (114.0 ± 12.5 cm vs 105.2 ± 8.7 cm, p = 0.007) and VAT (224.9(142.1; 316.1) cm2 vs 168.2(103.4; 195.3) cm2, p < 0.001) than those without. In univariate analysis, pancreatic PDFF in obese individuals correlated with BMI (r = 0.27, p = 0.03), waist circumference (r = 0.44, p < 0.001), VAT (r = 0.37, p = 0.004), hepatic PDFF (r = 0.25, p = 0.046) and diastolic blood pressure (r = 0.32, p = 0.01). However, in multivariate analysis, only VAT was associated to pancreatic fat content. MRI measures of pancreatic fibrosis indicated no evident fibrosis in relation to increased pancreatic fat content. CONCLUSIONS Pancreatic fat content was increased in obese individuals compared with lean controls and predominantly correlated with the amount of visceral adipose tissue. Pancreatic fat content was not clearly linked to measures of pancreatic fibrosis.
Collapse
Affiliation(s)
- Mimoza Gjela
- Department of Radiology, Aalborg University Hospital, Aalborg, Denmark
- Department of Clinical Biochemistry, Aalborg University Hospital, Aalborg, Denmark
| | - Anders Askeland
- Department of Clinical Biochemistry, Aalborg University Hospital, Aalborg, Denmark
- Department of Clinical Medicine, Aalborg University, Aalborg, Denmark
| | - Maiken Mellergaard
- Department of Clinical Biochemistry, Aalborg University Hospital, Aalborg, Denmark
- Department of Clinical Medicine, Aalborg University, Aalborg, Denmark
| | - Asbjørn Mohr Drewes
- Department of Clinical Medicine, Aalborg University, Aalborg, Denmark
- Department of Gastroenterology, Aalborg University Hospital, Aalborg, Denmark
| | - Aase Handberg
- Department of Clinical Biochemistry, Aalborg University Hospital, Aalborg, Denmark
- Department of Clinical Medicine, Aalborg University, Aalborg, Denmark
| | - Jens Brøndum Frøkjær
- Department of Radiology, Aalborg University Hospital, Aalborg, Denmark
- Department of Clinical Medicine, Aalborg University, Aalborg, Denmark
| |
Collapse
|
10
|
Huaroc Moquillaza E, Weiss K, Stelter J, Steinhelfer L, Lee YJ, Amthor T, Koken P, Makowski MR, Braren R, Doneva M, Karampinos DC. Accelerated liver water T 1 mapping using single-shot continuous inversion-recovery spiral imaging. NMR IN BIOMEDICINE 2024; 37:e5097. [PMID: 38269568 DOI: 10.1002/nbm.5097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 11/21/2023] [Accepted: 12/06/2023] [Indexed: 01/26/2024]
Abstract
PURPOSE Liver T1 mapping techniques typically require long breath holds or long scan time in free-breathing, need correction for B 1 + inhomogeneities and process composite (water and fat) signals. The purpose of this work is to accelerate the multi-slice acquisition of liver water selective T1 (wT1) mapping in a single breath hold, improving the k-space sampling efficiency. METHODS The proposed continuous inversion-recovery (IR) Look-Locker methodology combines a single-shot gradient echo spiral readout, Dixon processing and a dictionary-based analysis for liver wT1 mapping at 3 T. The sequence parameters were adapted to obtain short scan times. The influence of fat, B 1 + inhomogeneities and TE on the estimation of T1 was first assessed using simulations. The proposed method was then validated in a phantom and in 10 volunteers, comparing it with MRS and the modified Look-Locker inversion-recovery (MOLLI) method. Finally, the clinical feasibility was investigated by comparing wT1 maps with clinical scans in nine patients. RESULTS The phantom results are in good agreement with MRS. The proposed method encodes the IR-curve for the liver wT1 estimation, is minimally sensitive to B 1 + inhomogeneities and acquires one slice in 1.2 s. The volunteer results confirmed the multi-slice capability of the proposed method, acquiring nine slices in a breath hold of 11 s. The present work shows robustness to B 1 + inhomogeneities (wT 1 , No B 1 + = 1.07 wT 1 , B 1 + - 45.63 , R 2 = 0.99 ) , good repeatability (wT 1 , 2 ° = 1 . 0 wT 1 , 1 ° - 2.14 , R 2 = 0.96 ) and is in better agreement with MRS (wT 1 = 0.92 wT 1 MRS + 103.28 , R 2 = 0.38 ) than is MOLLI (wT 1 MOLLI = 0.76 wT 1 MRS + 254.43 , R 2 = 0.44 ) . The wT1 maps in patients captured diverse lesions, thus showing their clinical feasibility. CONCLUSION A single-shot spiral acquisition can be combined with a continuous IR Look-Locker method to perform rapid repeatable multi-slice liver water T1 mapping at a rate of 1.2 s per slice without a B 1 + map. The proposed method is suitable for nine-slice liver clinical applications acquired in a single breath hold of 11 s.
Collapse
Affiliation(s)
- Elizabeth Huaroc Moquillaza
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | | | - Jonathan Stelter
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Lisa Steinhelfer
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | | | | | | | - Marcus R Makowski
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Rickmer Braren
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | | | - Dimitrios C Karampinos
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| |
Collapse
|
11
|
Michelotti FC, Kupriyanova Y, Mori T, Küstner T, Heilmann G, Bombrich M, Möser C, Schön M, Kuss O, Roden M, Schrauwen-Hinderling VB. An Empirical Approach to Derive Water T 1 from Multiparametric MR Images Using an Automated Pipeline and Comparison With Liver Stiffness. J Magn Reson Imaging 2024; 59:1193-1203. [PMID: 37530755 DOI: 10.1002/jmri.28906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 06/30/2023] [Accepted: 06/30/2023] [Indexed: 08/03/2023] Open
Abstract
BACKGROUND Water T1 of the liver has been shown to be promising in discriminating the progressive forms of fatty liver diseases, inflammation, and fibrosis, yet proper correction for iron and lipid is required. PURPOSE To examine the feasibility of an empirical approach for iron and lipid correction when measuring imaging-based T1 and to validate this approach by spectroscopy on in vivo data. STUDY TYPE Retrospective. POPULATION Next to mixed lipid-iron phantoms, individuals with different hepatic lipid content were investigated, including people with type 1 diabetes (N = 15, %female = 15.6, age = 43.5 ± 14.0), or type 2 diabetes mellitus (N = 21, %female = 28.9, age = 59.8 ± 9.7) and healthy volunteers (N = 9, %female = 11.1, age = 58.0 ± 8.1). FIELD STRENGTH/SEQUENCES 3 T, balanced steady-state free precession MOdified Look-Locker Inversion recovery (MOLLI), multi- and dual-echo gradient echo Dixon, gradient echo magnetic resonance elastography (MRE). ASSESSMENT T1 values were measured in phantoms to determine the respective correction factors. The correction was tested in vivo and validated by proton magnetic resonance spectroscopy (1 H-MRS). The quantification of liver T1 based on automatic segmentation was compared to the T1 values based on manual segmentation. The association of T1 with MRE-derived liver stiffness was evaluated. STATISTICAL TESTS Bland-Altman plots and intraclass correlation coefficients (ICCs) were used for MOLLI vs. 1 H-MRS agreement and to compare liver T1 values from automatic vs. manual segmentation. Pearson's r correlation coefficients for T1 with hepatic lipids and liver stiffness were determined. A P-value of 0.05 was considered statistically significant. RESULTS MOLLI T1 values after correction were found in better agreement with the 1 H-MRS-derived water T1 (ICC = 0.60 [0.37; 0.76]) in comparison with the uncorrected T1 values (ICC = 0.18 [-0.09; 0.44]). Automatic quantification yielded similar liver T1 values (ICC = 0.9995 [0.9991; 0.9997]) as with manual segmentation. A significant correlation of T1 with liver stiffness (r = 0.43 [0.11; 0.67]) was found. A marked and significant reduction in the correlation strength of T1 with liver stiffness (r = 0.05 [-0.28; 0.38], P = 0.77) was found after correction for hepatic lipid content. DATA CONCLUSION Imaging-based correction factors enable accurate estimation of water T1 in vivo. LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Filippo C Michelotti
- Institute for Clinical Diabetology, German Diabetes Center, Leibniz Center for Diabetes Research at Heinrich Heine University, Düsseldorf, Germany
- German Center for Diabetes Research (DZD), Partner Düsseldorf, München-Neuherberg, Düsseldorf, Germany
| | - Yuliya Kupriyanova
- Institute for Clinical Diabetology, German Diabetes Center, Leibniz Center for Diabetes Research at Heinrich Heine University, Düsseldorf, Germany
- German Center for Diabetes Research (DZD), Partner Düsseldorf, München-Neuherberg, Düsseldorf, Germany
| | - Tim Mori
- German Center for Diabetes Research (DZD), Partner Düsseldorf, München-Neuherberg, Düsseldorf, Germany
- Institute for Biometrics and Epidemiology, German Diabetes Center, Leibniz Center for Diabetes Research at Heinrich Heine University Düsseldorf, Düsseldorf, Germany
| | - Thomas Küstner
- Diagnostics and Interventional Radiology, Medical Image and Data Analysis (MIDAS.lab), University Hospital of Tübingen, Tübingen, Germany
| | - Geronimo Heilmann
- Institute for Clinical Diabetology, German Diabetes Center, Leibniz Center for Diabetes Research at Heinrich Heine University, Düsseldorf, Germany
- German Center for Diabetes Research (DZD), Partner Düsseldorf, München-Neuherberg, Düsseldorf, Germany
| | - Maria Bombrich
- Institute for Clinical Diabetology, German Diabetes Center, Leibniz Center for Diabetes Research at Heinrich Heine University, Düsseldorf, Germany
- German Center for Diabetes Research (DZD), Partner Düsseldorf, München-Neuherberg, Düsseldorf, Germany
| | - Clara Möser
- Institute for Clinical Diabetology, German Diabetes Center, Leibniz Center for Diabetes Research at Heinrich Heine University, Düsseldorf, Germany
- German Center for Diabetes Research (DZD), Partner Düsseldorf, München-Neuherberg, Düsseldorf, Germany
- Department of Endocrinology and Diabetology, Medical Faculty and University Hospital Düsseldorf, Heinrich Heine University, Düsseldorf, Germany
| | - Martin Schön
- Institute for Clinical Diabetology, German Diabetes Center, Leibniz Center for Diabetes Research at Heinrich Heine University, Düsseldorf, Germany
- German Center for Diabetes Research (DZD), Partner Düsseldorf, München-Neuherberg, Düsseldorf, Germany
| | - Oliver Kuss
- German Center for Diabetes Research (DZD), Partner Düsseldorf, München-Neuherberg, Düsseldorf, Germany
- Institute for Biometrics and Epidemiology, German Diabetes Center, Leibniz Center for Diabetes Research at Heinrich Heine University Düsseldorf, Düsseldorf, Germany
- Centre for Health and Society, Faculty of Medicine, Heinrich Heine University, Düsseldorf, Germany
| | - Michael Roden
- Institute for Clinical Diabetology, German Diabetes Center, Leibniz Center for Diabetes Research at Heinrich Heine University, Düsseldorf, Germany
- German Center for Diabetes Research (DZD), Partner Düsseldorf, München-Neuherberg, Düsseldorf, Germany
- Department of Endocrinology and Diabetology, Medical Faculty and University Hospital Düsseldorf, Heinrich Heine University, Düsseldorf, Germany
| | - Vera B Schrauwen-Hinderling
- Institute for Clinical Diabetology, German Diabetes Center, Leibniz Center for Diabetes Research at Heinrich Heine University, Düsseldorf, Germany
- German Center for Diabetes Research (DZD), Partner Düsseldorf, München-Neuherberg, Düsseldorf, Germany
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre, Maastricht, The Netherlands
| |
Collapse
|
12
|
Meloni A, Carnevale A, Gaio P, Positano V, Passantino C, Pepe A, Barison A, Todiere G, Grigoratos C, Novani G, Pistoia L, Giganti M, Cademartiri F, Cossu A. Liver T1 and T2 mapping in a large cohort of healthy subjects: normal ranges and correlation with age and sex. MAGMA (NEW YORK, N.Y.) 2024; 37:93-100. [PMID: 38019376 DOI: 10.1007/s10334-023-01135-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Revised: 10/05/2023] [Accepted: 10/20/2023] [Indexed: 11/30/2023]
Abstract
OBJECTIVE We established normal ranges for native T1 and T2 values in the human liver using a 1.5 T whole-body imager (General Electric) and we evaluated their variation across hepatic segments and their association with age and sex. MATERIALS AND METHODS One-hundred healthy volunteers aged 20-70 years (50% females) underwent MRI. Modified Look-Locker inversion recovery and multi-echo fast-spin-echo sequences were used to measure hepatic native global and segmental T1 and T2 values, respectively. RESULTS T1 and T2 values exhibited good intra- and inter-observer reproducibility (coefficient of variation < 5%). T1 value over segment 4 was significantly lower than the T1 values over segments 2 and 3 (p < 0.0001). No significant regional T2 variability was detected. Segmental and global T1 values were not associated with age or sex. Global T2 values were independent from age but were significantly lower in males than in females. The lower and upper limits of normal for global T1 values were, respectively, 442 ms and 705 ms. The normal range for global T2 values was 35 ms-54 ms in males and 39 ms-54 ms in females. DISCUSSION Liver T1 and T2 mapping is feasible and reproducible and the provided normal ranges may help to establish diagnosis and progression of various liver diseases.
Collapse
Affiliation(s)
- Antonella Meloni
- Radiology Department, Fondazione G. Monasterio CNR-Regione Toscana, Via Moruzzi, 1-56124, Pisa, Italy
- Bioengineering Unit, Fondazione G. Monasterio CNR-Regione Toscana, Pisa, Italy
| | - Aldo Carnevale
- Department of Translational Medicine, University of Ferrara, Ferrara, Italy
| | - Paolo Gaio
- Department of Translational Medicine, University of Ferrara, Ferrara, Italy
| | - Vincenzo Positano
- Radiology Department, Fondazione G. Monasterio CNR-Regione Toscana, Via Moruzzi, 1-56124, Pisa, Italy
- Bioengineering Unit, Fondazione G. Monasterio CNR-Regione Toscana, Pisa, Italy
| | | | - Alessia Pepe
- Institute of Radiology, University of Padua, Padua, Italy
| | - Andrea Barison
- Division of Cardiology and Cardiovascular Medicine, Fondazione G. Monasterio CNR-Regione Toscana, Pisa, Italy
| | - Giancarlo Todiere
- Division of Cardiology and Cardiovascular Medicine, Fondazione G. Monasterio CNR-Regione Toscana, Pisa, Italy
| | - Chrysanthos Grigoratos
- Division of Cardiology and Cardiovascular Medicine, Fondazione G. Monasterio CNR-Regione Toscana, Pisa, Italy
| | - Giovanni Novani
- Radiology Department, Fondazione G. Monasterio CNR-Regione Toscana, Via Moruzzi, 1-56124, Pisa, Italy
| | - Laura Pistoia
- Radiology Department, Fondazione G. Monasterio CNR-Regione Toscana, Via Moruzzi, 1-56124, Pisa, Italy
- U.O.S.V.D. Ricerca Clinica, Fondazione G. Monasterio CNR-Regione Toscana, Pisa, Italy
| | | | - Filippo Cademartiri
- Radiology Department, Fondazione G. Monasterio CNR-Regione Toscana, Via Moruzzi, 1-56124, Pisa, Italy.
| | - Alberto Cossu
- University Radiology Unit, University of Ferrara, Ferrara, Italy
| |
Collapse
|
13
|
Liu CY, Noda C, van der Geest RJ, Triaire B, Kassai Y, Bluemke DA, Lima JAC. Sex-specific associations in multiparametric 3 T MRI measurements in adult livers. Abdom Radiol (NY) 2023; 48:3072-3078. [PMID: 37378865 DOI: 10.1007/s00261-023-03981-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 06/01/2023] [Accepted: 06/05/2023] [Indexed: 06/29/2023]
Abstract
BACKGROUND MRI relaxometry mapping and proton density fat fraction (PDFF) have been proposed for the evaluation of hepatic fibrosis. However, sex-specific relationships of age and body fat with these MRI parameters have not been studied in detail among adults without clinically manifest hepatic disease. We aimed to determine the sex-specific correlation of multiparametric MRI parameters with age and body fat and to evaluate their interplay associations. METHODS 147 study participants (84 women, mean age 48±14 years, range 19-85 years) were prospectively enrolled. 3 T MRI including T1, T2 and T1ρ mapping and PDFF and R2* map were acquired. Visceral and subcutaneous fat were measured on the fat images from Dixon water-fat separation sequence. RESULTS All MRI parameters demonstrated sex difference except for T1ρ. PDFF was more related to visceral than subcutaneous fat. Per 100 ml gain of visceral or subcutaneous fat is associated with 1 or 0.4% accretion of liver fat, respectively. PDFF and R2* were higher in men (both P = 0.01) while T1 and T2 were higher in women (both P < 0.01). R2* was positively but T1 and T2 were negatively associated with age in women (all P < 0.01), while T1ρ was positively related to age in men (P < 0.05). In all studies, R2* was positively and T1ρ was negatively associated with PDFF (both P <0.0001). CONCLUSION Visceral fat plays an essential role in the elevated liver fat. When using MRI parametric measures for liver disease evaluation, the interplay between these parameters should be considered.
Collapse
Affiliation(s)
| | - Chikara Noda
- Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Rob J van der Geest
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | | | | | - David A Bluemke
- Department of Radiology, University of Wisconsin, Madison, WI, USA
| | - João A C Lima
- Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| |
Collapse
|
14
|
Higashi M, Tanabe M, Yamane M, Keerthivasan MB, Imai H, Yonezawa T, Nakamura M, Ito K. Impact of fat on the apparent T1 value of the liver: assessment by water-only derived T1 mapping. Eur Radiol 2023; 33:6844-6851. [PMID: 37552261 DOI: 10.1007/s00330-023-10052-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Revised: 05/24/2023] [Accepted: 06/16/2023] [Indexed: 08/09/2023]
Abstract
OBJECTIVES To determine the impact of fat on the apparent T1 value of the liver using water-only derived T1 mapping. METHODS 3-T MRI included 2D Look-Locker T1 mapping and proton density fat fraction (PDFF) mapping. T1 values of the liver were compared among T1 maps obtained by in-phase (IP), opposed-phase (OP), and Dixon water sequences using paired t-test. The correlation between T1 values of the liver on each T1 map and PDFF was assessed using Spearman correlation coefficient. The absolute differences between T1 value of the liver on Dixon water images and that on IP or OP images were also correlated with PDFF. RESULTS One hundred sixty-two patients (median age, 70 [range, 24-91] years, 90 men) were retrospectively evaluated. The T1 values of the liver on each T1 map were significantly different (p < 0.001). The T1 value of the liver on IP images was significantly negatively correlated with PDFF (r = - 0.438), while the T1 value of the liver on OP images was slightly positively correlated with PDFF (r = 0.164). The T1 value of the liver on Dixon water images was slightly negatively correlated with PDFF (r = - 0.171). The absolute differences between T1 value of the liver on Dixon water images and that on IP or OP images were significantly correlated with PDFF (r = 0.606, 0.722; p < 0.001). CONCLUSION Fat correction for the apparent T1 value by water-only derived T1 maps will be helpful for accurately evaluating the T1 value of the liver. CLINICAL RELEVANCE STATEMENT Fat-corrected T1 mapping of the liver with the water component only obtained from the 2D Dixon Look-Locker sequence could be useful for accurately evaluating the T1 value of the liver without the impact of fat in daily clinical practice. KEY POINTS • The T1 values of the liver on the conventional T1 maps are significantly affected by the presence of fat. • The apparent T1 value of the liver on water-only derived T1 maps would be slightly impacted by the presence of fat. • Fat correction for the apparent T1 values is necessary for the accurate assessment of the T1 values of the liver.
Collapse
Affiliation(s)
- Mayumi Higashi
- Department of Radiology, Yamaguchi University Graduate School of Medicine, 1-1-1 Minami-Kogushi, Ube, Yamaguchi, 755-8505, Japan.
| | - Masahiro Tanabe
- Department of Radiology, Yamaguchi University Graduate School of Medicine, 1-1-1 Minami-Kogushi, Ube, Yamaguchi, 755-8505, Japan
| | - Masatoshi Yamane
- Department of Radiological Technology, Yamaguchi University Hospital, Yamaguchi, Japan
| | | | - Hiroshi Imai
- MR Research and Collaboration, Siemens Healthcare K.K., Tokyo, Japan
| | - Teppei Yonezawa
- Department of Radiological Technology, Yamaguchi University Hospital, Yamaguchi, Japan
| | - Michihiro Nakamura
- Department of Organ Anatomy & NANOMEDICINE, Yamaguchi University Graduate School of Medicine, Yamaguchi, Japan
| | - Katsuyoshi Ito
- Department of Radiology, Yamaguchi University Graduate School of Medicine, 1-1-1 Minami-Kogushi, Ube, Yamaguchi, 755-8505, Japan
| |
Collapse
|
15
|
Greidanus PG, Pagano JJ, Escudero CA, Thompson R, Tham EB. Regional Elevation of Liver T1 in Fontan Patients. CJC PEDIATRIC AND CONGENITAL HEART DISEASE 2023; 2:134-142. [PMID: 37969352 PMCID: PMC10642140 DOI: 10.1016/j.cjcpc.2023.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Accepted: 03/08/2023] [Indexed: 11/17/2023]
Abstract
Background Fontan-associated liver disease (FALD) is characterized by hepatic congestion and progressive hepatic fibrosis in patients with the Fontan operation. This condition is generally clinically silent until late, necessitating techniques for early detection. Liver T1 mapping has been used to screen for FALD, but without consideration of regional variations in T1 values. Methods Liver T1 measured with a liver-specific T1 mapping sequence (PROFIT1) in Fontan patients was compared with cohorts of patients with biventricular congenital heart disease (BiV-CHD) and controls with normal cardiac function and anatomy. Results Liver T1 was significantly elevated in the Fontan cohort (n = 20) compared with patients with BiV-CHD (n = 12) and controls (n = 9) (781, 678, and 675 milliseconds, respectively; P < 0.001), with a consistent pattern of significantly elevated T1 values in the peripheral compared with central liver regions (ΔT1 = 54, 2, and 11 milliseconds; P < 0.001). PROFIT1 also yielded simultaneous T2∗ maps and fat fraction values that were similar in all groups. Fontan liver T1 values were also significantly elevated as compared with BiV-CHD and controls as measured with the cardiac (modified Look-Locker inversion) acquisitions (728, 583, and 583 milliseconds, respectively; P < 0.001) and values correlated with PROFIT1 liver T1 (R = 0.87, P < 0.001). Conclusions Fontan patients have globally increased liver T1 values and consistent spatial variations, with higher values in the peripheral liver regions as compared with spatially uniform values in BiV-CHD and controls. The spatial patterns may provide insight into the progression of FALD. Liver T1 mapping studies should include uniform spatial coverage to avoid bias based on slice locations in this population.
Collapse
Affiliation(s)
- Paul G. Greidanus
- Division of Pediatric Cardiology, Stollery Children’s Hospital & Mazankowski Alberta Heart Institute, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Joseph J. Pagano
- Division of Pediatric Cardiology, Stollery Children’s Hospital & Mazankowski Alberta Heart Institute, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Carolina A. Escudero
- Division of Pediatric Cardiology, Stollery Children’s Hospital & Mazankowski Alberta Heart Institute, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Richard Thompson
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada
| | - Edythe B. Tham
- Division of Pediatric Cardiology, Stollery Children’s Hospital & Mazankowski Alberta Heart Institute, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
16
|
Wang Y, Qi H, Wang Y, Xiao M, Xiang C, Dong J, Chen H. Free-breathing simultaneous water-fat separation and T1 mapping of the whole liver (SWALI) with isotropic resolution using 3D golden-angle radial trajectory. Quant Imaging Med Surg 2023; 13:912-923. [PMID: 36819282 PMCID: PMC9929423 DOI: 10.21037/qims-22-748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2022] [Accepted: 12/01/2022] [Indexed: 01/05/2023]
Abstract
Background Conventional liver T1 mapping techniques are typically performed under breath-holding conditions; they have limited slice coverage and often rely on multiple acquisitions. Furthermore, liver fat affects the accuracy of T1 quantification. Therefore, we aim to propose a free-breathing technique for simultaneous water-fat separation and T1 mapping of the whole liver (SWALI) in a single scan. Methods The proposed SWALI sequence included an inversion recovery (IR) preparation pulse followed by a series of multiecho three-dimensional (3D) golden-angle radial acquisitions. For each echo time (TE), a series of images containing a mix of water and fat were reconstructed using a sliding window method. For each inversion time (TI), water and fat were separated, and then water and fat T1 estimation was conducted. The fat fraction (FF) was calculated based on the last TI image. The FF and water T1 quantification accuracy were compared with the gold standard sequences in the phantom. The in vivo feasibility was tested in 9 healthy volunteers, 2 patients with fatty liver, and 3 patients with hepatocellular carcinoma (HCC). The reproducibility was evaluated in the patients with fatty liver and in the healthy volunteers. Results The mean FF and the mean water T1 values obtained by the SWALI sequence showed good agreements with chemical shift-encoded magnetic resonance imaging (CSE-MRI; r=0.998; P<0.001) and fat-suppressed (FS) IR-spin echo (SE; r=0.997; P<0.001) in the phantom. For the patients with fatty liver and the healthy volunteers, the SWALI sequence showed no significant difference with CSE-MRI in FF quantification (P=0.53). In T1 quantification, comparable T1 values were obtained with the SWALI sequence and modified Look-Locker inversion recovery (MOLLI; P=0.10) in healthy volunteers, while the water T1 estimated by the SWALI sequence was significantly lower than the water-fat compound T1 estimated by MOLLI (P<0.001) in patients with fatty liver. In the reproducibility study, the intraclass correlation coefficients (ICCs) for the estimated FF and water T1 were 0.997 and 0.943, respectively. Water T1 of the patients with HCC calculated using the SWALI sequence showed a significant reduction after the contrast administration (P<0.001). Conclusions Free-breathing water-fat separation and T1 mapping of the whole liver with 2.5 mm isotropic spatial resolution were achieved simultaneously using the SWALI sequence in a 5-min scan.
Collapse
Affiliation(s)
- Yajie Wang
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Haikun Qi
- School of Biomedical Engineering, ShanghaiTech University, Shanghai, China
| | | | - Ming Xiao
- Department of Hepatobiliary Surgery, The Second Hospital of Shandong University, Jinan, China;,Hepato-Pancreato-Biliary Center, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, China
| | - Canhong Xiang
- Hepato-Pancreato-Biliary Center, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, China
| | - Jiahong Dong
- Hepato-Pancreato-Biliary Center, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, China
| | - Huijun Chen
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| |
Collapse
|
17
|
Roberts NT, Tamada D, Muslu Y, Hernando D, Reeder SB. Confounder-corrected T 1 mapping in the liver through simultaneous estimation of T 1 , PDFF, R 2 * , and B 1 + in a single breath-hold acquisition. Magn Reson Med 2023; 89:2186-2203. [PMID: 36656152 PMCID: PMC10139739 DOI: 10.1002/mrm.29590] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 12/23/2022] [Accepted: 01/01/2023] [Indexed: 01/20/2023]
Abstract
PURPOSE Quantitative volumetric T1 mapping in the liver has the potential to aid in the detection, diagnosis, and quantification of liver fibrosis, inflammation, and spatially resolved liver function. However, accurate measurement of hepatic T1 is confounded by the presence of fat and inhomogeneous B 1 + $$ {B}_1^{+} $$ excitation. Furthermore, scan time constraints related to respiratory motion require tradeoffs of reduced volumetric coverage and/or increased acquisition time. This work presents a novel 3D acquisition and estimation method for confounder-corrected T1 measurement over the entire liver within a single breath-hold through simultaneous estimation of T1 , fat and B 1 + $$ {B}_1^{+} $$ . THEORY AND METHODS The proposed method combines chemical shift encoded MRI and variable flip angle MRI with a B 1 + $$ {B}_1^{+} $$ mapping technique to enable confounder-corrected T1 mapping. The method was evaluated theoretically and demonstrated in both phantom and in vivo acquisitions at 1.5 and 3.0T. At 1.5T, the method was evaluated both pre- and post- contrast enhancement in healthy volunteers. RESULTS The proposed method demonstrated excellent linear agreement with reference inversion-recovery spin-echo based T1 in phantom acquisitions at both 1.5 and 3.0T, with minimal bias (5.2 and 45 ms, respectively) over T1 ranging from 200-1200 ms. In vivo results were in general agreement with reference saturation-recovery based 2D T1 maps (SMART1 Map, GE Healthcare). CONCLUSION The proposed 3D T1 mapping method accounts for fat and B 1 + $$ {B}_1^{+} $$ confounders through simultaneous estimation of T1 , B 1 + $$ {B}_1^{+} $$ , PDFF and R 2 * $$ {R}_2^{\ast } $$ . It demonstrates strong linear agreement with reference T1 measurements, with low bias and high precision, and can achieve full liver coverage in a single breath-hold.
Collapse
Affiliation(s)
- Nathan T Roberts
- Department of Radiology, University of Wisconsin - Madison, Madison, Wisconsin, USA.,Department of Electrical and Computer Engineering, University of Wisconsin - Madison, Madison, Wisconsin, USA
| | - Daiki Tamada
- Department of Radiology, University of Wisconsin - Madison, Madison, Wisconsin, USA
| | - Yavuz Muslu
- Department of Radiology, University of Wisconsin - Madison, Madison, Wisconsin, USA.,Department of Biomedical Engineering, University of Wisconsin - Madison, Madison, Wisconsin, USA
| | - Diego Hernando
- Department of Radiology, University of Wisconsin - Madison, Madison, Wisconsin, USA.,Department of Electrical and Computer Engineering, University of Wisconsin - Madison, Madison, Wisconsin, USA.,Department of Biomedical Engineering, University of Wisconsin - Madison, Madison, Wisconsin, USA.,Department of Medical Physics, University of Wisconsin - Madison, Madison, Wisconsin, USA
| | - Scott B Reeder
- Department of Radiology, University of Wisconsin - Madison, Madison, Wisconsin, USA.,Department of Biomedical Engineering, University of Wisconsin - Madison, Madison, Wisconsin, USA.,Department of Medical Physics, University of Wisconsin - Madison, Madison, Wisconsin, USA.,Department of Medicine, University of Wisconsin - Madison, Madison, Wisconsin, USA.,Department of Emergency Medicine, University of Wisconsin - Madison, Madison, Wisconsin, USA
| |
Collapse
|
18
|
Fellner C, Nickel MD, Kannengiesser S, Verloh N, Stroszczynski C, Haimerl M, Luerken L. Water-Fat Separated T1 Mapping in the Liver and Correlation to Hepatic Fat Fraction. Diagnostics (Basel) 2023; 13:diagnostics13020201. [PMID: 36673011 PMCID: PMC9858222 DOI: 10.3390/diagnostics13020201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 12/29/2022] [Accepted: 01/01/2023] [Indexed: 01/06/2023] Open
Abstract
(1) Background: T1 mapping in magnetic resonance imaging (MRI) of the liver has been proposed to estimate liver function or to detect the stage of liver disease, among others. Thus far, the impact of intrahepatic fat on T1 quantification has only been sparsely discussed. Therefore, the aim of this study was to evaluate the potential of water-fat separated T1 mapping of the liver. (2) Methods: A total of 386 patients underwent MRI of the liver at 3 T. In addition to routine imaging techniques, a 3D variable flip angle (VFA) gradient echo technique combined with a two-point Dixon method was acquired to calculate T1 maps from an in-phase (T1_in) and water-only (T1_W) signal. The results were correlated with proton density fat fraction using multi-echo 3D gradient echo imaging (PDFF) and multi-echo single voxel spectroscopy (PDFF_MRS). Using T1_in and T1_W, a novel parameter FF_T1 was defined and compared with PDFF and PDFF_MRS. Furthermore, the value of retrospectively calculated T1_W (T1_W_calc) based on T1_in and PDFF was assessed. Wilcoxon test, Pearson correlation coefficient and Bland-Altman analysis were applied as statistical tools. (3) Results: T1_in was significantly shorter than T1_W and the difference of both T1 values was correlated with PDFF (R = 0.890). FF_T1 was significantly correlated with PDFF (R = 0.930) and PDFF_MRS (R = 0.922) and yielded only minor bias compared to both established PDFF methods (0.78 and 0.21). T1_W and T1_W_calc were also significantly correlated (R = 0.986). (4) Conclusion: T1_W acquired with a water-fat separated VFA technique allows to minimize the influence of fat on liver T1. Alternatively, T1_W can be estimated retrospectively from T1_in and PDFF, if a Dixon technique is not available for T1 mapping.
Collapse
Affiliation(s)
- Claudia Fellner
- Department of Radiology, University Hospital Regensburg, 93053 Regensburg, Germany
| | | | | | - Niklas Verloh
- Department of Diagnostic and Interventional Radiology, Medical Center University of Freiburg, 79106 Freiburg, Germany
| | | | - Michael Haimerl
- Department of Radiology, University Hospital Regensburg, 93053 Regensburg, Germany
- Correspondence: (M.H.); (L.L.); Tel.: +49-941-944-7401 (M.H.)
| | - Lukas Luerken
- Department of Radiology, University Hospital Regensburg, 93053 Regensburg, Germany
- Correspondence: (M.H.); (L.L.); Tel.: +49-941-944-7401 (M.H.)
| |
Collapse
|
19
|
Li Z, Mathew M, Syed AB, Feng L, Brunsing R, Pauly JM, Vasanawala SS. Rapid fat-water separated T 1 mapping using a single-shot radial inversion-recovery spoiled gradient recalled pulse sequence. NMR IN BIOMEDICINE 2022; 35:e4803. [PMID: 35891586 DOI: 10.1002/nbm.4803] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 07/21/2022] [Accepted: 07/23/2022] [Indexed: 05/04/2023]
Abstract
T1 mapping is increasingly used in clinical practice and research studies. With limited scan time, existing techniques often have limited spatial resolution, contrast resolution and slice coverage. High fat concentrations yield complex errors in Look-Locker T1 methods. In this study, a dual-echo 2D radial inversion-recovery T1 (DEradIR-T1) technique was developed for fast fat-water separated T1 mapping. The DEradIR-T1 technique was tested in phantoms, 5 volunteers and 28 patients using a 3 T clinical MRI scanner. In our study, simulations were performed to analyze the composite (fat + water) and water-only T1 under different echo times (TE). In standardized phantoms, an inversion-recovery spin echo (IR-SE) sequence with and without fat saturation pulses served as a T1 reference. Parameter mapping with DEradIR-T1 was also assessed in vivo, and values were compared with modified Look-Locker inversion recovery (MOLLI). Bland-Altman analysis and two-tailed paired t-tests were used to compare the parameter maps from DEradIR-T1 with the references. Simulations of the composite and water-only T1 under different TE values and levels of fat matched the in vivo studies. T1 maps from DEradIR-T1 on a NIST phantom (Pcomp = 0.97) and a Calimetrix fat-water phantom (Pwater = 0.56) matched with the references. In vivo T1 was compared with that of MOLLI: R comp 2 = 0.77 ; R water 2 = 0.72 . In this work, intravoxel fat is found to have a variable, echo-time-dependent effect on measured T1 values, and this effect may be mitigated using the proposed DRradIR-T1.
Collapse
Affiliation(s)
- Zhitao Li
- Department of Radiology, Stanford University, Stanford, California, USA
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - Manoj Mathew
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Ali B Syed
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Li Feng
- Biomedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Ryan Brunsing
- Department of Radiology, Stanford University, Stanford, California, USA
| | - John M Pauly
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | | |
Collapse
|
20
|
Guo R, Chen Z, Amyar A, El-Rewaidy H, Assana S, Rodriguez J, Pierce P, Goddu B, Nezafat R. Improving accuracy of myocardial T 1 estimation in MyoMapNet. Magn Reson Med 2022; 88:2573-2582. [PMID: 35916305 DOI: 10.1002/mrm.29397] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 07/01/2022] [Accepted: 07/05/2022] [Indexed: 11/09/2022]
Abstract
PURPOSE To improve the accuracy and robustness of T1 estimation by MyoMapNet, a deep learning-based approach using 4 inversion-recovery T1 -weighted images for cardiac T1 mapping. METHODS MyoMapNet is a fully connected neural network for T1 estimation of an accelerated cardiac T1 mapping sequence, which collects 4 T1 -weighted images by a single Look-Locker inversion-recovery experiment (LL4). MyoMapNet was originally trained using in vivo data from the modified Look-Locker inversion recovery sequence, which resulted in significant bias and sensitivity to various confounders. This study sought to train MyoMapNet using signals generated from numerical simulations and phantom MR data under multiple simulated confounders. The trained model was then evaluated by phantom data scanned using new phantom vials that differed from those used for training. The performance of the new model was compared with modified Look-Locker inversion recovery sequence and saturation-recovery single-shot acquisition for measuring native and postcontrast T1 in 25 subjects. RESULTS In the phantom study, T1 values measured by LL4 with MyoMapNet were highly correlated with reference values from the spin-echo sequence. Furthermore, the estimated T1 had excellent robustness to changes in flip angle and off-resonance. Native and postcontrast myocardium T1 at 3 Tesla measured by saturation-recovery single-shot acquisition, modified Look-Locker inversion recovery sequence, and MyoMapNet were 1483 ± 46.6 ms and 791 ± 45.8 ms, 1169 ± 49.0 ms and 612 ± 36.0 ms, and 1443 ± 57.5 ms and 700 ± 57.5 ms, respectively. The corresponding extracellular volumes were 22.90% ± 3.20%, 28.88% ± 3.48%, and 30.65% ± 3.60%, respectively. CONCLUSION Training MyoMapNet with numerical simulations and phantom data will improve the estimation of myocardial T1 values and increase its robustness to confounders while also reducing the overall T1 mapping estimation time to only 4 heartbeats.
Collapse
Affiliation(s)
- Rui Guo
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Zhensen Chen
- Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, People's Republic of China
| | - Amine Amyar
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Hossam El-Rewaidy
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Salah Assana
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Jennifer Rodriguez
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Patrick Pierce
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Beth Goddu
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Reza Nezafat
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
21
|
Ghavamian A, Liu C, Kang B, Yuan X, Wang X, Gao L, Zhao X. Liver T1 relaxation time of the 'normal liver' in healthy Asians: measurement with MOLLI and B 1-corrected VFA methods at 3T. Br J Radiol 2022; 95:20211008. [PMID: 35324344 PMCID: PMC10993984 DOI: 10.1259/bjr.20211008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Revised: 01/15/2022] [Accepted: 02/02/2022] [Indexed: 01/01/2023] Open
Abstract
OBJECTIVES Liver T1 is a potential magnetic resonance imaging biomarker for liver diseases. This study aimed to determine the T1 relaxation time of the normal liver (PDFF<5%) in healthy Asian volunteers using modified look-locker inversion recovery (MOLLI) and B1 inhomogeneity-corrected variable flip angle (B1-corrected VFA). METHODS 60 healthy Asian volunteers without focal or diffuse liver disease underwent a liver scan at 3T magnetic resonance. Proton density fat fraction (PDFF) and liver stiffness measurements were applied for the quantification of liver fat and fibrosis. T1 mapping was performed with MOLLI and B1-corrected VFA sequences. Bland-Altman, linear regression, Student t-test, and one-way analysis of variance were used for statistical analysis. RESULTS The mean T1 relaxation times of the whole liver were 901 ± 34 ms by MOLLI, and 948 ± 29 ms by B1-corrected VFA in healthy volunteers. There was a strong correlation (r = 0.86, p < 0.0001) for liver T1 between two T1 mapping methods. There were significant differences between the right and left lobes in liver T1 relaxation times using both methods (p < 0.05). Gender and Asian ethnic disparities had no impact on liver T1 relaxation times. CONCLUSION T1 relaxation times of the normal liver (PDFF<5%) in healthy volunteers were established by MOLLI and B1-corrected VFA T1 mapping methods at 3T. It may provide suitable and robust baseline values for the assessment of liver diseases. ADVANCES IN KNOWLEDGE Gender and Asian ethnic disparities do not impact liver T1 relaxation time measurements.
Collapse
Affiliation(s)
- Armin Ghavamian
- Department of Radiology, Shandong Provincial Hospital, Cheeloo
College of Medicine, Shandong University,
Shandong, China
| | - Cuihong Liu
- Department of Radiology, Shandong Provincial Hospital, Cheeloo
College of Medicine, Shandong University,
Shandong, China
- Shandong Provincial Hospital Affiliated to Shandong First
Medical University, Shandong University,
Shandong, China
| | - Bing Kang
- Shandong Provincial Hospital Affiliated to Shandong First
Medical University, Shandong University,
Shandong, China
| | - Xianshun Yuan
- Shandong Provincial Hospital Affiliated to Shandong First
Medical University, Shandong University,
Shandong, China
| | - Ximing Wang
- Department of Radiology, Shandong Provincial Hospital, Cheeloo
College of Medicine, Shandong University,
Shandong, China
- Shandong Provincial Hospital Affiliated to Shandong First
Medical University, Shandong University,
Shandong, China
| | - Ling Gao
- Department of Endocrinology, Shandong Provincial Hospital
affiliated to Shandong University, Shandong Clinical Medical Center of
Endocrinology and Metabolism, Institute of Endocrinology and Metabolism,
Shandong Academy of Clinical Medicine,
Shandong, China
| | - Xinya Zhao
- Department of Radiology, Shandong Provincial Hospital, Cheeloo
College of Medicine, Shandong University,
Shandong, China
- Shandong Provincial Hospital Affiliated to Shandong First
Medical University, Shandong University,
Shandong, China
| |
Collapse
|
22
|
Wang N, Cao T, Han F, Xie Y, Zhong X, Ma S, Kwan A, Fan Z, Han H, Bi X, Noureddin M, Deshpande V, Christodoulou AG, Li D. Free-breathing multitasking multi-echo MRI for whole-liver water-specific T 1 , proton density fat fraction, and R2∗ quantification. Magn Reson Med 2022; 87:120-137. [PMID: 34418152 PMCID: PMC8616772 DOI: 10.1002/mrm.28970] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 07/24/2021] [Accepted: 07/26/2021] [Indexed: 01/03/2023]
Abstract
PURPOSE To develop a 3D multitasking multi-echo (MT-ME) technique for the comprehensive characterization of liver tissues with 5-min free-breathing acquisition; whole-liver coverage; a spatial resolution of 1.5 × 1.5 × 6 mm3 ; and simultaneous quantification of T1 , water-specific T1 (T1w ), proton density fat fraction (PDFF), and R2∗ . METHODS Six-echo bipolar spoiled gradient echo readouts following inversion recovery preparation was performed to generate T1 , water/fat, and R2∗ contrast. MR multitasking was used to reconstruct the MT-ME images with 3 spatial dimensions: 1 T1 recovery dimension, 1 multi-echo dimension, and 1 respiratory dimension. A basis function-based approach was developed for T1w quantification, followed by the estimation of R2∗ and T1 -corrected PDFF. The intrasession repeatability and agreement against references of MT-ME measurements were tested on a phantom and 15 clinically healthy subjects. In addition, 4 patients with confirmed liver diseases were recruited, and the agreement between MT-ME measurements and references was assessed. RESULTS MT-ME produced high-quality, coregistered T1 , T1w , PDFF, and R2∗ maps with good intrasession repeatability and substantial agreement with references on phantom and human studies. The intra-class coefficients of T1 , T1w , PDFF, and R2∗ from the repeat MT-ME measurements on clinically healthy subjects were 0.989, 0.990, 0.999, and 0.988, respectively. The intra-class coefficients of T1 , PDFF, and R2∗ between the MT-ME and reference measurements were 0.924, 0.987, and 0.975 in healthy subjects and 0.980, 0.999, and 0.998 in patients. The T1w was independent to PDFF (R = -0.029, P = .904). CONCLUSION The proposed MT-ME technique quantifies T1 , T1w , PDFF, and R2∗ simultaneously and is clinically promising for the comprehensive characterization of liver tissue properties.
Collapse
Affiliation(s)
- Nan Wang
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Tianle Cao
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA,Department of Bioengineering, University of California, Los Angeles, CA, USA
| | - Fei Han
- MR Research and Development, Siemens Medical Solutions USA, Inc., Los Angeles, CA, USA
| | - Yibin Xie
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Xiaodong Zhong
- MR Research and Development, Siemens Medical Solutions USA, Inc., Los Angeles, CA, USA
| | - Sen Ma
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Alan Kwan
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA,Departments of Imaging and Cardiology, Cedars-Sinai Medical Center, Los Angeles, CA
| | - Zhaoyang Fan
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA,Department of Radiology, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Hui Han
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Xiaoming Bi
- MR Research and Development, Siemens Medical Solutions USA, Inc., Los Angeles, CA, USA
| | - Mazen Noureddin
- Karsh Division of Gastroenterology & Hepatology, Comprehensive Transplant Center, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Vibhas Deshpande
- MR Research and Development, Siemens Medical Solutions USA, Inc., Austin, TX, USA
| | - Anthony G. Christodoulou
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA,Department of Bioengineering, University of California, Los Angeles, CA, USA
| | - Debiao Li
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA,Department of Bioengineering, University of California, Los Angeles, CA, USA,Corresponding Author Contact Information: Debiao Li, Ph.D., Director, Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, 8700 Beverly Blvd, PACT 400, Los Angeles, California, USA 90048, Phone: 310-423-7743,
| |
Collapse
|
23
|
Cicolari D, Lizio D, Pedrotti P, Moioli MT, Lascialfari A, Mariani M, Torresin A. A method for T 1 and T 2 relaxation times validation and harmonization as a support to MRI mapping. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2022; 334:107110. [PMID: 34844075 DOI: 10.1016/j.jmr.2021.107110] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 11/09/2021] [Accepted: 11/17/2021] [Indexed: 06/13/2023]
Abstract
We present a proof-of-concept study focusing on a method for the intra- and inter-center validation and harmonization of data obtained from MRI T1 and T2 maps. The method is based on a set of MnCl2 samples that provide in-scan ground-truth reference values regardless of the details of the MRI protocol. The relaxation times of MnCl2 aqueous solutions were first measured by means of an NMR laboratory relaxometer, as a function of concentration and temperature. The obtained T1 and T2 values, once renormalized at the scanner temperature, were used as reference values for the MRI mapping measurements of the MnCl2 relaxation times. By using different clinical MRI scanners and sequences, we found a good agreement for standard and turbo sequences (limits of agreement: 5% for IR, SE, IR-TSE; 10% for TSE), while an under-estimation and an over-estimation were found respectively for MOLLI and T2-prep TrueFISP, as already reported in the literature. The linearity of the relaxation rates with the concentration predicted by the Solomon-Bloembergen-Morgan theory was observed for every dataset at all temperatures, except for T2-prep TrueFISP maps results. Some preliminary results of an in vivo experiment are also presented.
Collapse
Affiliation(s)
- Davide Cicolari
- University of Pavia, Department of Physics, and INFN-Pavia Unit, Via Bassi 6, 27100 Pavia, Italy.
| | - Domenico Lizio
- ASST Grande Ospedale Metropolitano Niguarda, Department of Medical Physics, P.zza Ospedale Maggiore 3, 20162 Milan, Italy.
| | - Patrizia Pedrotti
- ASST Grande Ospedale Metropolitano Niguarda, Department of Cardiology, P.zza Ospedale Maggiore 3, 20162 Milan, Italy.
| | - Monica Teresa Moioli
- ASST Grande Ospedale Metropolitano Niguarda, Department of Medical Physics, P.zza Ospedale Maggiore 3, 20162 Milan, Italy.
| | - Alessandro Lascialfari
- University of Pavia, Department of Physics, and INFN-Pavia Unit, Via Bassi 6, 27100 Pavia, Italy.
| | - Manuel Mariani
- University of Pavia, Department of Physics, and INFN-Pavia Unit, Via Bassi 6, 27100 Pavia, Italy.
| | - Alberto Torresin
- ASST Grande Ospedale Metropolitano Niguarda, Department of Medical Physics, P.zza Ospedale Maggiore 3, 20162 Milan, Italy; University of Milan, Department of Physics, Via Celoria 16, 20133 Milan, Italy.
| |
Collapse
|
24
|
von Ulmenstein S, Bogdanovic S, Honcharova-Biletska H, Blümel S, Deibel AR, Segna D, Jüngst C, Weber A, Kuntzen T, Gubler C, Reiner CS. Assessment of hepatic fibrosis and inflammation with look-locker T1 mapping and magnetic resonance elastography with histopathology as reference standard. Abdom Radiol (NY) 2022; 47:3746-3757. [PMID: 36038643 PMCID: PMC9560941 DOI: 10.1007/s00261-022-03647-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 08/04/2022] [Accepted: 08/08/2022] [Indexed: 01/18/2023]
Abstract
PURPOSE To compare the diagnostic performance of T1 mapping and MR elastography (MRE) for staging of hepatic fibrosis and grading inflammation with histopathology as standard of reference. METHODS 68 patients with various liver diseases undergoing liver biopsy for suspected fibrosis or with an established diagnosis of cirrhosis prospectively underwent look-locker inversion recovery T1 mapping and MRE. T1 relaxation time and liver stiffness (LS) were measured by two readers. Hepatic fibrosis and inflammation were histopathologically staged according to a standardized fibrosis (F0-F4) and inflammation (A0-A2) score. For statistical analysis, independent t test, and Mann-Whitney U test and ROC analysis were performed, the latter to determine the performance of T1 mapping and MRE for fibrosis staging and inflammation grading, as compared to histopathology. RESULTS Histopathological analysis diagnosed 9 patients with F0 (13.2%), 21 with F1 (30.9%), 11 with F2 (16.2%), 10 with F3 (14.7%), and 17 with F4 (25.0%). Both T1 mapping and MRE showed significantly higher values for patients with significant fibrosis (F0-1 vs. F2-4; T1 mapping p < 0.0001, MRE p < 0.0001) as well as for patients with severe fibrosis or cirrhosis (F0-2 vs. F3-4; T1 mapping p < 0.0001, MRE p < 0.0001). T1 values and MRE LS were significantly higher in patients with inflammation (A0 vs. A1-2, both p = 0.01). T1 mapping showed a tendency toward lower diagnostic performance without statistical significance for significant fibrosis (F2-4) (AUC 0.79 vs. 0.91, p = 0.06) and with a significant difference compared to MRE for severe fibrosis (F3-4) (AUC 0.79 vs. 0.94, p = 0.03). For both T1 mapping and MRE, diagnostic performance for diagnosing hepatic inflammation (A1-2) was low (AUC 0.72 vs. 0.71, respectively). CONCLUSION T1 mapping is able to diagnose hepatic fibrosis, however, with a tendency toward lower diagnostic performance compared to MRE and thus may be used as an alternative to MRE for diagnosing hepatic fibrosis, whenever MRE is not available or likely to fail due to intrinsic factors of the patient. Both T1 mapping and MRE are probably not sufficient as standalone methods to diagnose hepatic inflammation with relatively low diagnostic accuracy.
Collapse
Affiliation(s)
- Sophie von Ulmenstein
- Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland
| | - Sanja Bogdanovic
- Diagnostic Radiology, Balgrist University Hospital, Zurich, Switzerland
| | | | - Sena Blümel
- Division of Gastroenterology and Hepatology, University Hospital Zurich, Zurich, Switzerland
| | - Ansgar R Deibel
- Division of Gastroenterology and Hepatology, University Hospital Zurich, Zurich, Switzerland
| | - Daniel Segna
- Division of Gastroenterology and Hepatology, University Hospital Zurich, Zurich, Switzerland
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Christoph Jüngst
- Division of Gastroenterology and Hepatology, University Hospital Zurich, Zurich, Switzerland
| | - Achim Weber
- Department of Pathology and Molecular Pathology, University Hospital Zurich, Zurich, Switzerland
| | - Thomas Kuntzen
- Gastroenterology and Hepatology, Kantonsspital Aarau, Aarau, Switzerland
| | - Christoph Gubler
- Gastroenterology and Hepatology, Stadtspital Triemli, Zurich, Switzerland
| | - Cäcilia S Reiner
- Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.
| |
Collapse
|
25
|
Evaluation of liver T1 using MOLLI gradient echo readout under the influence of fat. Magn Reson Imaging 2021; 85:57-63. [PMID: 34678435 DOI: 10.1016/j.mri.2021.10.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2021] [Revised: 10/14/2021] [Accepted: 10/16/2021] [Indexed: 11/22/2022]
Abstract
BACKGROUND The effect of hepatic steatosis on the gradient-echo (GRE) based Modified Look-Locker Inversion Recovery (MOLLI) technique for T1 mapping has not been evaluated. The purpose of this study was to evaluate a GRE based MOLLI technique for hepatic T1 mapping and determine the relationship of T1 differences (ΔT1) on in-phase (IP) and out-of-phase (OP) to fat fraction (FF) measurement. MATERIALS AND METHODS 3 T MRI included MOLLI T1 mapping with TE = 1.3 (OP), 2.4 (IP), and 1.8 ms, and chemical-shift-encoded sequence with spectral modeling of fat to generate FF map as a reference. Bloch simulations and oil/water phantoms were used to characterize the response of the MOLLI T1 in various FF < 30% since MOLLI T1 estimation was erratic beyond this limit. Curve fit between ΔT1 and FF from simulation was applied to validate the phantom and the in-vivo results. Thirty-eight normal volunteers were included (16 women, Age 44 ± 12 years, BMI 27 ± 5.3 kg/m2). MOLLI water images were reconstructed by the average of OP and IP images, and the T1 values on water images served as the reference for T1 bias calculation defined as the percent difference between OP, IP, TE = 1.8 ms and the referenced water T1. Linear regression was performed to correlate the FF quantified by the reference and MOLLI methods. RESULTS Phantom results were consistent with the Bloch simulations. The simulated relationship between FF (0-30%) and ΔT1 could be modeled precisely by a cubic equation with R2 = 1. In-vivo MOLLI ΔT1 and estimated FF were correlated to the reference FF (both R2 ≥ 0.96 and P < 0.001). TE = 1.8 ms demonstrated less T1 bias (-1.34%) compared to TE = OP (5.32%) or IP (-3.8%, both P < 0.001). CONCLUSION At 3 T, TE of 1.8 ms can be used to reduce the T1 bias and deliver consistent T1 values when FF is <30%.
Collapse
|
26
|
Mózes FE, Valkovič L, Pavlides M, Robson MD, Tunnicliffe EM. Hydration and glycogen affect T 1 relaxation times of liver tissue. NMR IN BIOMEDICINE 2021; 34:e4530. [PMID: 33951228 DOI: 10.1002/nbm.4530] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Accepted: 04/05/2021] [Indexed: 06/12/2023]
Abstract
T1 mapping is a useful tool for the assessment of patients with nonalcoholic fatty liver disease but still suffers from a large unexplained variance in healthy subjects. This study aims to characterize the potential effects of liver glycogen concentration and body hydration status on liver shortened modified Look-Locker inversion recovery (shMOLLI) T1 measurements. Eleven glycogen phantoms and 12 healthy volunteers (mean age: 31 years, three females) were scanned at 3 T using inversion recovery spin echo, multiple contrast spin echo (in phantoms), shMOLLI T1 mapping, multiple-echo spoiled gradient recalled echo and 13 C spectroscopy (in healthy volunteers). Phantom r1 and r2 relaxivities were determined from measured T1 and T2 values. Participants underwent a series of five metabolic experiments to vary their glycogen concentration and hydration levels: feeding, food fasting, exercising, underhydration, and rehydration. Descriptive statistics were calculated for shMOLLI T1 , inferior vena cava to aorta cross-sectional area ratio (IVC/Ao) as a marker of body hydration status, glycogen concentration, T2 * and proton density fat fraction values. A linear mixed model for shMOLLI R1 was constructed to determine the effects of glycogen concentration and IVC/Ao ratio. The mean shMOLLI T1 after fasting was 737 ± 67 ms. The mean within-subject change was 80 ± 45 ms. The linear mixed model revealed a glycogen r1 relaxivity in volunteers (0.18 M-1 s-1 , p = 0.03) close to that determined in phantoms (0.28 M-1 s-1 ). A unit change in IVC/Ao ratio was associated with a drop of -0.113 s-1 in R1 (p < 0.001). This study demonstrated a dependence of liver shMOLLI T1 values on liver glycogen concentration and overall body hydration status. Interparticipant variation of hydration status should be minimized in future liver MRI studies. Additionally, caution is advised when interpreting liver T1 measurements in participants with excess liver glycogen.
Collapse
Affiliation(s)
- Ferenc E Mózes
- The Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Oxford, UK
| | - Ladislav Valkovič
- The Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Oxford, UK
- Department of Imaging Methods, Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia
| | - Michael Pavlides
- The Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Oxford, UK
- Translational Gastroenterology Unit, University of Oxford, Oxford, UK
- Oxford NIHR Biomedical Research Centre, University of Oxford and Oxford Radcliffe Hospitals NHS Trust, Oxford, UK
| | - Matthew D Robson
- The Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Oxford, UK
- Perspectum, Gemini One, Oxford, UK
| | - Elizabeth M Tunnicliffe
- The Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Oxford, UK
- Oxford NIHR Biomedical Research Centre, University of Oxford and Oxford Radcliffe Hospitals NHS Trust, Oxford, UK
| |
Collapse
|
27
|
Jayaswal ANA, Levick C, Collier J, Tunnicliffe EM, Kelly MD, Neubauer S, Barnes E, Pavlides M. Liver cT 1 decreases following direct-acting antiviral therapy in patients with chronic hepatitis C virus. Abdom Radiol (NY) 2021; 46:1947-1957. [PMID: 33247768 PMCID: PMC8131342 DOI: 10.1007/s00261-020-02860-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Revised: 11/04/2020] [Accepted: 11/07/2020] [Indexed: 02/07/2023]
Abstract
PURPOSE Direct-acting antiviral therapies (DAAs) for treatment of chronic hepatitis C virus (HCV) have excellent rates of viral eradication, but their effect on regression of liver fibrosis is unclear. The primary aim was to use magnetic resonance imaging (MRI) and spectroscopy (MRS) to evaluate changes in liver fibrosis, liver fat and liver iron content (LIC) in patients with chronic HCV following treatment with DAAs. METHODS In this prospective study, 15 patients with chronic HCV due to start treatment with DAAs and with transient elastography (TE) > 8 kPa were recruited consecutively. Patients underwent MRI and MRS at baseline (before treatment), and at 24 weeks and 48 weeks after the end of treatment (EoT) for the measurement of liver cT1 (fibroinflammation), liver fat and T2* (LIC). RESULTS All patients achieved a sustained virological response. Liver cT1 showed significant decreases from baseline to 24 weeks post EoT (876 vs 806 ms, p = 0.002, n = 15), baseline to 48 weeks post EoT (876 vs 788 ms, p = 0.0002, n = 13) and 24 weeks post EoT to 48 weeks post EoT (806 vs 788 ms, p = 0.016, n = 13). Between baseline and 48 weeks EoT significant reduction in liver fat (5.17% vs 2.65%, p = 0.027) and an increase in reported LIC (0.913 vs 0.950 mg/g, p = 0.021) was observed. CONCLUSION Liver cT1 decreases in patients with chronic HCV undergoing successful DAA treatment. The relatively fast reduction in cT1 suggests a reduction in inflammation rather than regression of fibrosis.
Collapse
Affiliation(s)
- Arjun N A Jayaswal
- Oxford Centre for Clinical Magnetic Resonance Research, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK
| | - Christina Levick
- Oxford Centre for Clinical Magnetic Resonance Research, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK
- Translational Gastroenterology Unit, University of Oxford, Oxford, UK
| | - Jane Collier
- Translational Gastroenterology Unit, University of Oxford, Oxford, UK
| | - Elizabeth M Tunnicliffe
- Oxford Centre for Clinical Magnetic Resonance Research, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK
- Oxford NIHR Biomedical Research Centre, Oxford, UK
| | | | - Stefan Neubauer
- Oxford Centre for Clinical Magnetic Resonance Research, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK
- Oxford NIHR Biomedical Research Centre, Oxford, UK
| | - Eleanor Barnes
- Translational Gastroenterology Unit, University of Oxford, Oxford, UK
- Oxford NIHR Biomedical Research Centre, Oxford, UK
- Peter Medawar Building for Pathogen Research, University of Oxford, Oxford, UK
| | - Michael Pavlides
- Oxford Centre for Clinical Magnetic Resonance Research, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK.
- Translational Gastroenterology Unit, University of Oxford, Oxford, UK.
- Oxford NIHR Biomedical Research Centre, Oxford, UK.
| |
Collapse
|
28
|
Chacko L, Boldrini M, Martone R, Law S, Martinez-Naharrro A, Hutt DF, Kotecha T, Patel RK, Razvi Y, Rezk T, Cohen OC, Brown JT, Srikantharajah M, Ganesananthan S, Lane T, Lachmann HJ, Wechalekar AD, Sachchithanantham S, Mahmood S, Whelan CJ, Knight DS, Moon JC, Kellman P, Gillmore JD, Hawkins PN, Fontana M. Cardiac Magnetic Resonance-Derived Extracellular Volume Mapping for the Quantification of Hepatic and Splenic Amyloid. Circ Cardiovasc Imaging 2021; 14:CIRCIMAGING121012506. [PMID: 33876651 DOI: 10.1161/circimaging.121.012506] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Systemic amyloidosis is characterized by amyloid deposition that can involve virtually any organ. Splenic and hepatic amyloidosis occurs in certain types, in some patients but not others, and may influence prognosis and treatment. SAP (serum amyloid P component) scintigraphy is uniquely able to identify and quantify amyloid in the liver and spleen, thus informing clinical management, but it is only available in 2 centers globally. The aims of this study were to examine the potential for extracellular volume (ECV) mapping performed during routine cardiac magnetic resonance to: (1) detect amyloid in the liver and spleen and (2) estimate amyloid load in these sites using SAP scintigraphy as the reference standard. METHODS Five hundred thirty-three patients referred to the National Amyloidosis Centre, London, between 2015 and 2017 with suspected systemic amyloidosis who underwent SAP scintigraphy and cardiac magnetic resonance with T1 mapping were studied. RESULTS The diagnostic performance of ECV to detect splenic and hepatic amyloidosis was high for both organs (liver: area under the curve, -0.917 [95% CI, 0.880-0.954]; liver ECV cutoff, 0.395; sensitivity, 90.7%; specificity, 77.7%; P<0.001; spleen: area under the curve, -0.944 [95% CI, 0.925-0.964]; spleen ECV cutoff, 0.385; sensitivity, 93.6%; specificity, 87.5%; P<0.001). There was good correlation between liver and spleen ECV and amyloid load assessed by SAP scintigraphy (r=0.504, P<0.001; r=0.693, P<0.001, respectively). There was high interobserver agreement for both the liver and spleen (ECV liver intraclass correlation coefficient, 0.991 [95% CI, 0.984-0.995]; P<0.001; ECV spleen intraclass correlation coefficient, 0.995 [95% CI, 0.991-0.997]; P<0.001) with little bias across a wide range of ECV values. CONCLUSIONS Our study demonstrates that ECV measurements obtained during routine cardiac magnetic resonance scans in patients with suspected amyloidosis can identify and measure the magnitude of amyloid infiltration in the liver and spleen, providing important clues to amyloid type and offering a noninvasive measure of visceral amyloid burden that can help guide and track treatment.
Collapse
Affiliation(s)
| | | | - Raffaele Martone
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
- Department of Heart, Lung and Vessels, Tuscan Regional Amyloid Center, Careggi University Hospital, Florence, Italy (R.M.)
| | - Steven Law
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | - Ana Martinez-Naharrro
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | - David F Hutt
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | | | - Rishi K Patel
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | - Yousuf Razvi
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | - Tamer Rezk
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | - Oliver C Cohen
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | - James T Brown
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | - Mukunthan Srikantharajah
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | - Sharmananthan Ganesananthan
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | - Thirusha Lane
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | - Helen J Lachmann
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | - Ashutosh D Wechalekar
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | - Sajitha Sachchithanantham
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | - Shameem Mahmood
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | - Carol J Whelan
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | - Daniel S Knight
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | - James C Moon
- Institute of Cardiovascular Science, University College London, London, United Kingdom. (J.C.M.)
- Barts Heart Centre, Cardiovascular Magnetic Resonance Imaging Unit, and the Inherited Cardiovascular Diseases Unit, St Bartholomew's Hospital, London, United Kingdom (J.C.M.)
| | - Peter Kellman
- Department of Health and Human Services, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD (P.K.)
| | - Julian D Gillmore
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | - Philip N Hawkins
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| | - Marianna Fontana
- Division of Medicine, National Amyloidosis Centre, University College London, London, United Kingdom. (L.C., M.B., R.M., S.L., A.M.-N., D.F.H., T.K., R.K.P., Y.R., T.R., O.C.C., J.B., M.S., S.G., T.L., H.L., A.W., S.S., S.M., C.W., D.S.K., J.G., P.N.H., M.F.)
| |
Collapse
|
29
|
Ahn JH, Yu JS, Park KS, Kang SH, Huh JH, Chang JS, Lee JH, Kim MY, Nickel MD, Kannengiesser S, Kim JY, Koh SB. Effect of hepatic steatosis on native T1 mapping of 3T magnetic resonance imaging in the assessment of T1 values for patients with non-alcoholic fatty liver disease. Magn Reson Imaging 2021; 80:1-8. [PMID: 33798658 DOI: 10.1016/j.mri.2021.03.015] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 03/18/2021] [Accepted: 03/18/2021] [Indexed: 02/09/2023]
Abstract
PURPOSE This study investigated whether T1 values in native T1 mapping of 3T magnetic resonance imaging (MRI) of the liver were affected by the fatty component. METHODS This prospective study involved 340 participants from a population-based cohort study between May 8, 2018 and August 8, 2019. Data obtained included: (1) hepatic stiffness according to magnetic resonance elastography (MRE); (2) T1 value according to T1 mapping; (3) fat fraction and iron concentration from multi-echo Dixon; and (4) clinical indices of hepatic steatosis including body mass index, waist circumference, history of diabetes, aspartate aminotransferase, alanine aminotransferase, gamma-glutamyl transpeptidase, and triglycerides. The correlations between T1 value and fat fraction, and between T1 value and liver stiffness were assessed using Pearson's correlation coefficient. The independent two-sample t-test was used to evaluate the differences in T1 values according to the presence or absence of hepatic steatosis, and the one-way analysis of variance was used to evaluate the difference in T1 value by grading of hepatic steatosis according to MRI-based proton density fat fraction (PDFF). In addition, univariate and multivariate linear regression analyses were performed to determine whether other variables influenced the T1 value. RESULTS T1 value showed a positive correlation with the fat fraction obtained from PDFF (r = 0.615, P < 0.001) and with the liver stiffness obtained from MRE (r = 0.370, P < 0.001). Regardless of the evaluation method, the T1 value was significantly increased in subjects with hepatic steatosis (P < 0.001). When comparing hepatic steatosis grades based on MRI-PDFF, the mean T1 values were significantly different in all grades, and the T1 value tended to increase as the grade increased (P < 0.001, P for trend <0.001). On multiple linear regression analysis, the T1 value was influenced by MRI-PDFF, calculated liver iron concentration, liver stiffness, and serum aspartate aminotransferase level. CONCLUSION The T1 value obtained by current T1 mapping of 3T MRI was affected by the liver fat component and several other factors such as liver stiffness, iron concentration, and inflammation.
Collapse
Affiliation(s)
- Jhii-Hyun Ahn
- Department of Radiology, Wonju Severance Christian Hospital, Yonsei University College of Medicine, Republic of Korea
| | - Jeong-Sik Yu
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
| | - Kyu-Sang Park
- Mitohormesis Research Center, Department of Physiology, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
| | - Seong Hee Kang
- Department of Internal Medicine, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
| | - Ji Hye Huh
- Department of Internal Medicine, Hallym University Sacred Heart Hospital, Anyang, Republic of Korea
| | - Jae Seung Chang
- Mitohormesis Research Center, Department of Physiology, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
| | - Jong-Han Lee
- Department of Laboratory Medicine, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
| | - Moon Young Kim
- Department of Internal Medicine, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
| | | | | | - Jang-Young Kim
- Department of Internal Medicine, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
| | - Sang-Baek Koh
- Department of Preventive Medicine, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
| |
Collapse
|
30
|
Mózes FE, Tunnicliffe EM. Differences between T1 and corrected T1 cannot be attributed to iron-correction only. Pediatr Radiol 2021; 51:499-500. [PMID: 33502540 DOI: 10.1007/s00247-020-04956-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Revised: 11/23/2020] [Accepted: 12/20/2020] [Indexed: 12/22/2022]
Affiliation(s)
- Ferenc E Mózes
- Oxford Centre for Clinical Magnetic Resonance Research, RDM Cardiovascular Medicine, University of Oxford, Oxford, OX3 9DU, UK.
| | - Elizabeth M Tunnicliffe
- Oxford Centre for Clinical Magnetic Resonance Research, RDM Cardiovascular Medicine, University of Oxford, Oxford, OX3 9DU, UK
| |
Collapse
|
31
|
Erden A, Kuru Öz D, Peker E, Kul M, Ateş FSÖ, Erden İ, İdilman R. MRI quantification techniques in fatty liver: the diagnostic performance of hepatic T1, T2, and stiffness measurements in relation to the proton density fat fraction. Diagn Interv Radiol 2021; 27:7-14. [PMID: 33290237 PMCID: PMC7837725 DOI: 10.5152/dir.2020.19654] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 03/22/2020] [Accepted: 04/05/2020] [Indexed: 12/12/2022]
Abstract
PURPOSE Nonalcoholic fatty liver disease (NAFLD) can progress to liver cirrhosis and is predicted to become the most frequent indication for liver transplantation in the near future. Noninvasive assessment of NAFLD is important for diagnosis and patient management. This study aims to prospectively determine the liver stiffness and T1 and T2 values in patients with NAFLD and to compare the diagnostic performance of magnetic resonance elastography (MRE) and mapping techniques in relation to the proton density fat fraction (PDFF). METHODS Eighty-three patients with NAFLD and 26 participants with normal livers were imaged with a 1.5 T scanner. PDFF measurements obtained from the multiecho Dixon technique were used to quantify the liver fat. MRE, native T1 mapping (modified Look-Locker inversion recovery [MOLLI] schemes 5(3)3, 3(3)3(3)5, and 3(2)3(2)5 and the B1-corrected variable flip angle [VFA] method), and T2 mapping values were correlated with PDFF. The diagnostic performance of MRE and the mapping techniques were analyzed and compared. RESULTS T1 values measured with the MOLLI schemes and the B1-corrected VFA (P < 0.001), and the stiffness values from MRE (P = 0.047) were significantly higher in the NAFLD group. No significant difference was found between the groups in terms of T2 values (P = 0.127). In differentiation of the NAFLD and control groups, the B1-corrected VFA technique had slightly higher accuracy and area under the curve (AUC) than the MOLLI schemes. In the NAFLD group, there was a good correlation between the PDFF, MOLLI 3(3)3(3)5 and 3(2)3(2)5, and VFA T1 measurements (r=0.732; r=0.735; r=0.716, P < 0.001, respectively). CONCLUSION Liver T1 mapping techniques have the potential to distinguish steatotic from nonsteatotic livers, and T1 values seem to have a strong correlation with the liver fat content.
Collapse
Affiliation(s)
- Ayşe Erden
- From the Departments of Radiology (A.E., D.K.Ö. , E.P., M.K., İ.E.), Biostatistics (F.S.Ö.A.), and Gastroenterology (R.İ.), Ankara University School of Medicine, Ankara, Turkey
| | - Diğdem Kuru Öz
- From the Departments of Radiology (A.E., D.K.Ö. , E.P., M.K., İ.E.), Biostatistics (F.S.Ö.A.), and Gastroenterology (R.İ.), Ankara University School of Medicine, Ankara, Turkey
| | - Elif Peker
- From the Departments of Radiology (A.E., D.K.Ö. , E.P., M.K., İ.E.), Biostatistics (F.S.Ö.A.), and Gastroenterology (R.İ.), Ankara University School of Medicine, Ankara, Turkey
| | - Melahat Kul
- From the Departments of Radiology (A.E., D.K.Ö. , E.P., M.K., İ.E.), Biostatistics (F.S.Ö.A.), and Gastroenterology (R.İ.), Ankara University School of Medicine, Ankara, Turkey
| | - Funda Seher Özalp Ateş
- From the Departments of Radiology (A.E., D.K.Ö. , E.P., M.K., İ.E.), Biostatistics (F.S.Ö.A.), and Gastroenterology (R.İ.), Ankara University School of Medicine, Ankara, Turkey
| | - İlhan Erden
- From the Departments of Radiology (A.E., D.K.Ö. , E.P., M.K., İ.E.), Biostatistics (F.S.Ö.A.), and Gastroenterology (R.İ.), Ankara University School of Medicine, Ankara, Turkey
| | - Ramazan İdilman
- From the Departments of Radiology (A.E., D.K.Ö. , E.P., M.K., İ.E.), Biostatistics (F.S.Ö.A.), and Gastroenterology (R.İ.), Ankara University School of Medicine, Ankara, Turkey
| |
Collapse
|
32
|
Thomaides-Brears HB, Lepe R, Banerjee R, Duncker C. Multiparametric MR mapping in clinical decision-making for diffuse liver disease. Abdom Radiol (NY) 2020; 45:3507-3522. [PMID: 32761254 PMCID: PMC7593302 DOI: 10.1007/s00261-020-02684-3] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Revised: 06/12/2020] [Accepted: 07/22/2020] [Indexed: 02/07/2023]
Abstract
Accurate diagnosis, monitoring and treatment decisions in patients with chronic liver disease currently rely on biopsy as the diagnostic gold standard, and this has constrained early detection and management of diseases that are both varied and can be concurrent. Recent developments in multiparametric magnetic resonance imaging (mpMRI) suggest real potential to bridge the diagnostic gap between non-specific blood-based biomarkers and invasive and variable histological diagnosis. This has implications for the clinical care and treatment pathway in a number of chronic liver diseases, such as haemochromatosis, steatohepatitis and autoimmune or viral hepatitis. Here we review the relevant MRI techniques in clinical use and their limitations and describe recent potential applications in various liver diseases. We exemplify case studies that highlight how these techniques can improve clinical practice. These techniques could allow clinicians to increase their arsenals available to utilise on patients and direct appropriate treatments.
Collapse
Affiliation(s)
| | - Rita Lepe
- Texas Liver Institute, 607 Camden St, Suite 101, San Antonio, TX, 78215, USA
| | | | - Carlos Duncker
- Perspectum, 600 N. Pearl St. Suite 1960, Plaza of The Americas, Dallas, TX, 75201, USA
| |
Collapse
|
33
|
Validation and feasibility of liver T1 mapping using free breathing MOLLI sequence in children and young adults. Sci Rep 2020; 10:18390. [PMID: 33110134 PMCID: PMC7591907 DOI: 10.1038/s41598-020-74717-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Accepted: 10/05/2020] [Indexed: 12/20/2022] Open
Abstract
We investigated the feasibility of free-breathing modified Look-Locker inversion recovery (MOLLI) sequence for measuring hepatic T1 values in children and young adults. To investigate the accuracy and the reproducibility of the T1 maps, a phantom study was performed with 12 different gadoterate meglumine concentrations and the T1 relaxation times of phantoms measured with the MOLLI sequence were compared against those measured with three different sequences: spin-echo inversion recovery, variable flip angle (VFA), and VFA with B1 correction. To evaluate the feasibility of free-breathing MOLLI sequence, hepatic T1 relaxation times obtained by free-breathing and breath-hold technique in twenty patients were compared. The phantom study revealed the excellent accuracy and reproducibility of MOLLI. In twenty patients, the mean value of hepatic T1 values obtained by free-breathing (606.7 ± 64.5 ms) and breath-hold (609.8 ± 64.0 ms) techniques showed no significant difference (p > 0.05). The Bland–Altman plot between the free-breathing and breath-hold revealed that the mean difference of T1 values was − 3.0 ms (− 0.5%). Therefore, T1 relaxation times obtained by MOLLI were comparable to the values obtained using the standard inversion recovery method. The hepatic T1 relaxation times measured by MOLLI technique with free-breathing were comparable to those obtained with breath-hold in children and young adults.
Collapse
|
34
|
Zhao R, Hamilton G, Brittain JH, Reeder SB, Hernando D. Design and evaluation of quantitative MRI phantoms to mimic the simultaneous presence of fat, iron, and fibrosis in the liver. Magn Reson Med 2020; 85:734-747. [PMID: 32783200 DOI: 10.1002/mrm.28452] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 07/08/2020] [Accepted: 07/08/2020] [Indexed: 12/20/2022]
Abstract
PURPOSE To design, construct, and evaluate quantitative MR phantoms that mimic MRI signals from the liver with simultaneous control of three parameters: proton-density fat fraction (PDFF), R 2 ∗ , and T1 . These parameters are established biomarkers of hepatic steatosis, iron overload, and fibrosis/inflammation, respectively, which can occur simultaneously in the liver. METHODS Phantoms including multiple vials were constructed. Peanut oil was used to modulate PDFF, MnCl2 and iron microspheres were used to modulate R 2 ∗ , and NiCl2 was used to modulate the T1 of water (T1,water ). Phantoms were evaluated at both 1.5 T and 3 T using stimulated-echo acquisition-mode MRS and chemical shift-encoded MRI. Stimulated-echo acquisition-mode MRS data were processed to estimate T1,water , T1,fat , R 2 , water ∗ , and R 2 , fat ∗ for each vial. Chemical shift-encoded MRI data were processed to generate PDFF and R 2 ∗ maps, and measurements were obtained in each vial. Measurements were evaluated using linear regression and Bland-Altman analysis. RESULTS High-quality PDFF and R 2 ∗ maps were obtained with homogeneous values throughout each vial. High correlation was observed between imaging PDFF with target PDFF (slope = 0.94-0.97, R2 = 0.994-0.997) and imaging R 2 ∗ with target R 2 ∗ (slope = 0.84-0.88, R2 = 0.935-0.943) at both 1.5 T and 3 T. The values of R 2 , fat ∗ and R 2 , water ∗ were highly correlated with slope close to 1.0 at both 1.5 T (slope = 0.90, R2 = 0.988) and 3 T (slope = 0.99, R2 = 0.959), similar to the behavior observed in vivo. The value of T1,water (500-1200 ms) was controlled with varying NiCl2 concentration, while T1,fat (300 ms) was independent of NiCl2 concentration. CONCLUSION Novel quantitative MRI phantoms that mimic the simultaneous presence of fat, iron, and fibrosis in the liver were successfully developed and validated.
Collapse
Affiliation(s)
- Ruiyang Zhao
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Gavin Hamilton
- Department of Radiology, University of California-San Diego, San Diego, California, USA
| | - Jean H Brittain
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Calimetrix LLC, Madison, Wisconsin, USA
| | - Scott B Reeder
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Calimetrix LLC, Madison, Wisconsin, USA.,Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Emergency Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Diego Hernando
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Calimetrix LLC, Madison, Wisconsin, USA
| |
Collapse
|
35
|
Thompson RB, Chow K, Mager D, Pagano JJ, Grenier J. Simultaneous proton density fat-fraction and R 2 ∗ imaging with water-specific T 1 mapping (PROFIT 1 ): application in liver. Magn Reson Med 2020; 85:223-238. [PMID: 32754942 DOI: 10.1002/mrm.28434] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 06/22/2020] [Accepted: 06/23/2020] [Indexed: 12/17/2022]
Abstract
PURPOSE To describe and validate a simultaneous proton density fat-fraction (PDFF) imaging and water-specific T1 mapping (T1(Water) ) approach for the liver (PROFIT1 ) with R 2 ∗ mapping and low sensitivity to B 1 + calibration or inhomogeneity. METHODS A multiecho gradient-echo sequence, with and without saturation preparation, was designed for simultaneous imaging of liver PDFF, R 2 ∗ , and T1(Water) (three slices in ~13 seconds). Chemical-shift-encoded MRI processing yielded fat-water separated images and R 2 ∗ maps. T1(Water) calculation utilized saturation and nonsaturation-recovery water-separated images. Several variable flip angle schemes across k-space (increasing flip angles in sequential RF pulses) were evaluated for minimization of T1 weighting, to reduce the B 1 + dependence of T1(Water) and PDFF (reduced flip angle dependence). T1(Water) accuracy was validated in mixed fat-water phantoms, with various PDFF and T1 values (3T). In vivo application was illustrated in five volunteers and five patients with nonalcoholic fatty liver disease (PDFF, T1(Water) , R 2 ∗ ). RESULTS A sin3 (θ) flip angle pattern (0 < θ < π/2 over k-space) yielded the largest PROFIT1 signal yield with negligible B 1 + dependence for both T1(Water) and PDFF. Mixed fat-water phantom experiments illustrated excellent agreement between PROFIT1 and gold-standard spectroscopic evaluation of PDFF and T1(Water) (<1% T1 error). In vivo PDFF, T1(Water) , and R 2 ∗ maps illustrated independence of the PROFIT1 values from B 1 + inhomogeneity and significant differences between volunteers and patients with nonalcoholic fatty liver disease for T1(Water) (927 ± 56 ms vs. 1033 ± 23 ms; P < .05) and PDFF (2.0% ± 0.8% vs. 13.4% ± 5.0%, P < .05). R 2 ∗ was similar between groups. CONCLUSION The PROFIT1 pulse sequence provides fast simultaneous quantification of PDFF, T1(Water) , and R 2 ∗ with minimal sensitivity to B 1 + miscalibration or inhomogeneity.
Collapse
Affiliation(s)
- Richard B Thompson
- Department of Biomedical Engineering, University of Alberta, Edmonton, AB, Canada
| | - Kelvin Chow
- Cardiovascular MR R&D, Siemens Medical Solutions USA, Inc., Chicago, IL, USA
| | - Diana Mager
- Department of Agriculture Food and Nutrition Science, University of Alberta, Edmonton, AB, Canada
| | - Joseph J Pagano
- Department of Biomedical Engineering, University of Alberta, Edmonton, AB, Canada
| | - Justin Grenier
- Department of Biomedical Engineering, University of Alberta, Edmonton, AB, Canada
| |
Collapse
|
36
|
Multiparametric MR Index for the Diagnosis of Non-Alcoholic Steatohepatitis in Patients with Non-Alcoholic Fatty Liver Disease. Sci Rep 2020; 10:2671. [PMID: 32060386 PMCID: PMC7021895 DOI: 10.1038/s41598-020-59601-3] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Accepted: 01/31/2020] [Indexed: 02/06/2023] Open
Abstract
Non-alcoholic steatohepatitis (NASH) is a complex disease consisting of various components including steatosis, lobular inflammation, and ballooning degeneration, with or without fibrosis. Therefore, it is difficult to diagnose NASH with only one imaging modality. This study was aimed to evaluate the feasibility of magnetic resonance imaging (MRI) for predicting NASH and to develop a non-invasive multiparametric MR index for the detection of NASH in non-alcoholic fatty liver disease (NAFLD) patients. This prospective study included 47 NAFLD patients who were scheduled to undergo or underwent ultrasound-guided liver biopsy within 2 months. Biopsy specimens were graded as NASH or non-NASH. All patients underwent non-enhanced MRI including MR spectroscopy (MRS), MR elastography (MRE), and T1 mapping. Diagnostic performances of MRS, MRE, and T1 mapping for grading steatosis, activity, and fibrosis were evaluated. A multiparametric MR index combining fat fraction (FF), liver stiffness (LS) value, and T1 relaxation time was developed using linear regression analysis. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of the newly devised MR index. Twenty NASH patients and 27 non-NASH patients were included. Using MRS, MRE, and T1 mapping, the mean areas under the curve (AUCs) for grading steatosis, fibrosis, and activity were 0.870, 0.951, and 0.664, respectively. The multiparametric MR index was determined as 0.037 × FF (%) + 1.4 × LS value (kPa) + 0.004 × T1 relaxation time (msec) −3.819. ROC curve analysis of the MR index revealed an AUC of 0.883. The cut-off value of 6 had a sensitivity of 80.0% and specificity of 85.2%. The multiparametric MR index combining FF, LS value, and T1 relaxation time showed high diagnostic performance for detecting NASH in NAFLD patients.
Collapse
|
37
|
Dennis A, Kelly MD, Fernandes C, Mouchti S, Fallowfield JA, Hirschfield G, Pavlides M, Harrison S, Chakravarthy MV, Banerjee R, Sanyal A. Correlations Between MRI Biomarkers PDFF and cT1 With Histopathological Features of Non-Alcoholic Steatohepatitis. Front Endocrinol (Lausanne) 2020; 11:575843. [PMID: 33584535 PMCID: PMC7877451 DOI: 10.3389/fendo.2020.575843] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Accepted: 11/30/2020] [Indexed: 12/22/2022] Open
Abstract
INTRODUCTION Late stage clinical trials in non-alcoholic steatohepatitis (NASH) are currently required by the FDA to use liver biopsy as a primary endpoint. The well-reported limitations with biopsy, such as associated risks and sampling error, coupled with patient preference, are driving investigation into non-invasive alternatives. MRI-derived biomarkers proton density fat fraction (PDFF) and iron-corrected T1 mapping (cT1) are gaining traction as emerging alternatives to biopsy for NASH. Our aim was to explore the correlations between cT1 and PDFF (from LiverMultiScan®), with the histological components on the NAFLD-NASH spectrum in a large cohort of cross-sectional data, in order to calibrate the measurement to histology, and to infer what might constitute a clinically meaningful change when related to the FDA's criteria. MATERIALS AND METHODS In a retrospective analysis of data combined from three previously published observational NASH studies, in which adult participants who underwent liver biopsy on suspicion of NAFLD or NASH and had an MRI scan measuring cT1 and PDFF (LiverMultiScan®, Perspectum Ltd, UK), associations between imaging biomarkers and histology were tested using Spearman's rank correlation coefficient (rs), and further exploration of the relationships between the imaging variables and histology were performed using linear regression. RESULTS N = 264 patients with mean age of 54 (SD:9.9), 39% female, and 69% with BMI ≥ 30kg.m-2 were included in the analysis. cT1 and PDFF both correlated with all features of the NAFLD activity score (NAS). cT1 was also positively correlated with Kleiner-Brunt fibrosis. Partial correlations, adjusting for steatosis, revealed cT1 correlated with inflammation and fibrosis, whereas PDFF did not, and both were still associated with the NAS, but correlation was weaker with PDFF than cT1. An estimated difference of 88 ms in cT1, or 21% relative difference in PDFF was related to a two-point difference in overall NAS. CONCLUSION The correlations between cT1 and PDFF with the histopathological hallmarks of NASH demonstrate the potential utility of both cT1 and PDFF as non-invasive biomarkers to detect a pharmacodynamic change in NASH, with cT1 showing superiority for detecting changes in inflammation and fibrosis, rather than liver fat alone.
Collapse
Affiliation(s)
- Andrea Dennis
- Perspectum, Oxford, United Kingdom
- *Correspondence: Andrea Dennis,
| | | | | | | | | | - Gideon Hirschfield
- Toronto Centre for Liver Disease, University Health Network, Toronto, ON, Canada
| | - Michael Pavlides
- Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom
- Translational Gastroenterology Unit, University of Oxford, Oxford, United Kingdom
- Oxford NIHR Biomedical Research Centre, University of Oxford, Oxford, United Kingdom
| | - Stephen Harrison
- Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom
- Pinnacle Clinical Research, San Antonio, TX, United States
| | | | | | - Arun Sanyal
- Division of Gastroenterology, Hepatology and Nutrition, Department of Internal Medicine, Virginia Commonwealth University, Richmond, VA, United States
| |
Collapse
|
38
|
Non-invasive assessment of portal hypertension by multi-parametric magnetic resonance imaging of the spleen: A proof of concept study. PLoS One 2019; 14:e0221066. [PMID: 31430314 PMCID: PMC6701782 DOI: 10.1371/journal.pone.0221066] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Accepted: 07/29/2019] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND AND AIMS Non-invasive assessment of portal hypertension is an area of unmet need. This proof of concept study aimed to evaluate the diagnostic accuracy of a multi-parametric magnetic resonance technique in the assessment of portal hypertension. Comparison to other non-invasive technologies was a secondary aim. METHODS T1 and T2* maps through the liver and spleen were acquired prior to trans-jugular liver biopsy and hepatic vein pressure gradient (HVPG) measurement. T1 measurements reflect changes in tissue water content, but this relationship is confounded by the presence of iron, which in turn can be quantified accurately from T2* maps. Data were analysed using LiverMultiScan (Perspectum Diagnostics, Oxford, UK) which applies an algorithm to remove the confounding effect of iron, yielding the "iron corrected T1" (cT1). Sensitivity, specificity, diagnostic values and area under the curve were derived for spleen cT1, liver cT1, transient elastography, and serum fibrosis scores. HVPG was the reference standard. RESULTS Nineteen patients (15 men) with median age 57 years were included. Liver disease aetiologies included non-alcoholic fatty liver disease (n = 9; 47%) and viral hepatitis (n = 4; 21%). There was strong correlation between spleen cT1 and HVPG (r = 0.69; p = 0.001). Other non-invasive biomarkers did not correlate with HVPG. Spleen cT1 had excellent diagnostic accuracy for portal hypertension (HVPG >5 mmHg) and clinically significant portal hypertension (HVPG ≥10 mmHg) with an area under the receiver operating characteristic curve of 0.92 for both. CONCLUSION Spleen cT1 is a promising biomarker of portal pressure that outperforms other non-invasive scores and should be explored further.
Collapse
|
39
|
Obmann VC, Mertineit N, Marx C, Berzigotti A, Ebner L, Heverhagen JT, Christe A, Huber AT. Liver MR relaxometry at 3T - segmental normal T 1 and T 2* values in patients without focal or diffuse liver disease and in patients with increased liver fat and elevated liver stiffness. Sci Rep 2019; 9:8106. [PMID: 31147588 PMCID: PMC6542826 DOI: 10.1038/s41598-019-44377-y] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Accepted: 05/10/2019] [Indexed: 02/07/2023] Open
Abstract
Magnetic resonance (MR) T1 and T2* mapping allows quantification of liver relaxation times for non-invasive characterization of diffuse liver disease. We hypothesized that liver relaxation times are not only influenced by liver fibrosis, inflammation and fat, but also by air in liver segments adjacent to the lung – especially in MR imaging at 3T. A total of 161 study participants were recruited, while 6 patients had to be excluded due to claustrophobia or technically uninterpretable MR elastography. Resulting study population consisted of 12 healthy volunteers and 143 patients who prospectively underwent multiparametric MR imaging at 3T. Of those 143 patients, 79 had normal liver stiffness in MR elastography (shear modulus <2.8 kPa, indicating absence of fibrosis) and normal proton density fat fraction (PDFF < 10%, indicating absence of steatosis), defined as reference population. T1 relaxation times in these patients were significantly shorter in liver segments adjacent to the lung than in those not adjacent to the lung (p < 0.001, mean of differences 33 ms). In liver segments not adjacent to the lung, T1 allowed to differentiate significantly between the reference population and patients with steatosis and/or fibrosis (p ≤ 0.011), while there was no significant difference of T1 between the reference population and healthy volunteers. In conclusion, we propose to measure T1 relaxation times in liver segments not adjacent to the lung. Otherwise, we recommend taking into account slightly shorter T1 values in liver segments adjacent to the lung.
Collapse
Affiliation(s)
- V C Obmann
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, INO B, Freiburgstrasse 10, 3010, Bern, Switzerland
| | - N Mertineit
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, INO B, Freiburgstrasse 10, 3010, Bern, Switzerland
| | - C Marx
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, INO B, Freiburgstrasse 10, 3010, Bern, Switzerland
| | - A Berzigotti
- Hepatology, Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, INO A, Freiburgstrasse 10, 3010, Bern, Switzerland
| | - L Ebner
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, INO B, Freiburgstrasse 10, 3010, Bern, Switzerland
| | - J T Heverhagen
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, INO B, Freiburgstrasse 10, 3010, Bern, Switzerland
| | - A Christe
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, INO B, Freiburgstrasse 10, 3010, Bern, Switzerland
| | - A T Huber
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, INO B, Freiburgstrasse 10, 3010, Bern, Switzerland.
| |
Collapse
|
40
|
Bachtiar V, Kelly MD, Wilman HR, Jacobs J, Newbould R, Kelly CJ, Gyngell ML, Groves KE, McKay A, Herlihy AH, Fernandes CC, Halberstadt M, Maguire M, Jayaratne N, Linden S, Neubauer S, Banerjee R. Repeatability and reproducibility of multiparametric magnetic resonance imaging of the liver. PLoS One 2019; 14:e0214921. [PMID: 30970039 PMCID: PMC6457552 DOI: 10.1371/journal.pone.0214921] [Citation(s) in RCA: 59] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2018] [Accepted: 03/24/2019] [Indexed: 12/15/2022] Open
Abstract
As the burden of liver disease reaches epidemic levels, there is a high unmet medical need to develop robust, accurate and reproducible non-invasive methods to quantify liver tissue characteristics for use in clinical development and ultimately in clinical practice. This prospective cross-sectional study systematically examines the repeatability and reproducibility of iron-corrected T1 (cT1), T2*, and hepatic proton density fat fraction (PDFF) quantification with multiparametric MRI across different field strengths, scanner manufacturers and models. 61 adult participants with mixed liver disease aetiology and those without any history of liver disease underwent multiparametric MRI on combinations of 5 scanner models from two manufacturers (Siemens and Philips) at different field strengths (1.5T and 3T). We report high repeatability and reproducibility across different field strengths, manufacturers, and scanner models in standardized cT1 (repeatability CoV: 1.7%, bias -7.5ms, 95% LoA of -53.6 ms to 38.5 ms; reproducibility CoV 3.3%, bias 6.5 ms, 95% LoA of -76.3 to 89.2 ms) and T2* (repeatability CoV: 5.5%, bias -0.18 ms, 95% LoA -5.41 to 5.05 ms; reproducibility CoV 6.6%, bias -1.7 ms, 95% LoA -6.61 to 3.15 ms) in human measurements. PDFF repeatability (0.8%) and reproducibility (0.75%) coefficients showed high precision of this metric. Similar precision was observed in phantom measurements. Inspection of the ICC model indicated that most of the variance in cT1 could be accounted for by study participants (ICC = 0.91), with minimal contribution from technical differences. We demonstrate that multiparametric MRI is a non-invasive, repeatable and reproducible method for quantifying liver tissue characteristics across manufacturers (Philips and Siemens) and field strengths (1.5T and 3T).
Collapse
Affiliation(s)
| | | | - Henry R. Wilman
- Perspectum Diagnostics Ltd, Oxford, United Kingdom
- Department of Life Sciences, University of Westminster, London, United Kingdom
| | - Jaco Jacobs
- Perspectum Diagnostics Ltd, Oxford, United Kingdom
| | | | | | | | | | - Andy McKay
- Perspectum Diagnostics Ltd, Oxford, United Kingdom
| | | | | | | | | | | | | | - Stefan Neubauer
- Perspectum Diagnostics Ltd, Oxford, United Kingdom
- Oxford Centre for Clinical Magnetic Resonance Research, Radcliffe Department of Medicine, University of Oxford, Oxford United Kingdom
| | | |
Collapse
|
41
|
MR fingerprinting with simultaneous T 1, T 2, and fat signal fraction estimation with integrated B 0 correction reduces bias in water T 1 and T 2 estimates. Magn Reson Imaging 2019; 60:7-19. [PMID: 30910696 DOI: 10.1016/j.mri.2019.03.017] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Revised: 03/15/2019] [Accepted: 03/19/2019] [Indexed: 12/26/2022]
Abstract
PURPOSE MR fingerprinting (MRF) sequences permit efficient T1 and T2 estimation in cranial and extracranial regions, but these areas may include substantial fat signals that bias T1 and T2 estimates. MRI fat signal fraction estimation is also a topic of active research in itself, but may be complicated by B0 heterogeneity and blurring during spiral k-space acquisitions, which are commonly used for MRF. An MRF method is proposed that separates fat and water signals, estimates water T1 and T2, and accounts for B0 effects with spiral blurring correction, in a single sequence. THEORY AND METHODS A k-space-based fat-water separation method is further extended to unbalanced steady-state free precession MRF with swept echo time. Repeated application of this k-space fat-water separation to demodulated forms of the measured data allows a B0 map and correction to be approximated. The method is compared with MRF without fat separation across a broad range of fat signal fractions (FSFs), water T1s and T2s, and under heterogeneous static fields in simulations, phantoms, and in vivo. RESULTS The proposed method's FSF estimates had a concordance correlation coefficient of 0.990 with conventional measurements, and reduced biases in the T1 and T2 estimates due to fat signal relative to other MRF sequences by several hundred ms. The B0 correction improved the FSF, T1, and T2 estimation compared to those estimates without correction. CONCLUSION The proposed method improves MRF water T1 and T2 estimation in the presence of fat and provides accurate FSF estimation with inline B0 correction.
Collapse
|
42
|
Mozes FE, Tunnicliffe EM, Moolla A, Marjot T, Levick CK, Pavlides M, Robson MD. Mapping tissue water T 1 in the liver using the MOLLI T 1 method in the presence of fat, iron and B 0 inhomogeneity. NMR IN BIOMEDICINE 2019; 32:e4030. [PMID: 30462873 PMCID: PMC6492199 DOI: 10.1002/nbm.4030] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2018] [Revised: 09/11/2018] [Accepted: 09/20/2018] [Indexed: 05/11/2023]
Abstract
Modified Look-Locker inversion recovery (MOLLI) T1 mapping sequences can be useful in cardiac and liver tissue characterization, but determining underlying water T1 is confounded by iron, fat and frequency offsets. This article proposes an algorithm that provides an independent water MOLLI T1 (referred to as on-resonance water T1 ) that would have been measured if a subject had no fat and normal iron, and imaging had been done on resonance. Fifteen NiCl2 -doped agar phantoms with different peanut oil concentrations and 30 adults with various liver diseases, nineteen (63.3%) with liver steatosis, were scanned at 3 T using the shortened MOLLI (shMOLLI) T1 mapping, multiple-echo spoiled gradient-recalled echo and 1 H MR spectroscopy sequences. An algorithm based on Bloch equations was built in MATLAB, and water shMOLLI T1 values of both phantoms and human participants were determined. The quality of the algorithm's result was assessed by Pearson's correlation coefficient between shMOLLI T1 values and spectroscopically determined T1 values of the water, and by linear regression analysis. Correlation between shMOLLI and spectroscopy-based T1 values increased, from r = 0.910 (P < 0.001) to r = 0.998 (P < 0.001) in phantoms and from r = 0.493 (for iron-only correction; P = 0.005) to r = 0.771 (for iron, fat and off-resonance correction; P < 0.001) in patients. Linear regression analysis revealed that the determined water shMOLLI T1 values in patients were independent of fat and iron. It can be concluded that determination of on-resonance water (sh)MOLLI T1 independent of fat, iron and macroscopic field inhomogeneities was possible in phantoms and human subjects.
Collapse
Affiliation(s)
- Ferenc E. Mozes
- The University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, John Radcliffe HospitalOxfordUK
| | - Elizabeth M. Tunnicliffe
- The University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, John Radcliffe HospitalOxfordUK
| | - Ahmad Moolla
- The University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, John Radcliffe HospitalOxfordUK
- Oxford Centre for Diabetes, Endocrinology and Metabolism (OCDEM)University of Oxford, Churchill HospitalOxfordUK
| | - Thomas Marjot
- Oxford Centre for Diabetes, Endocrinology and Metabolism (OCDEM)University of Oxford, Churchill HospitalOxfordUK
| | - Christina K. Levick
- The University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, John Radcliffe HospitalOxfordUK
- Translational Gastroenterology UnitUniversity of Oxford, John Radcliffe HospitalOxfordUK
| | - Michael Pavlides
- The University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, John Radcliffe HospitalOxfordUK
- Translational Gastroenterology UnitUniversity of Oxford, John Radcliffe HospitalOxfordUK
- Oxford NIHR Biomedical Research CentreOxfordUK
| | - Matthew D. Robson
- The University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, John Radcliffe HospitalOxfordUK
| |
Collapse
|
43
|
Mojtahed A, Kelly CJ, Herlihy AH, Kin S, Wilman HR, McKay A, Kelly M, Milanesi M, Neubauer S, Thomas EL, Bell JD, Banerjee R, Harisinghani M. Reference range of liver corrected T1 values in a population at low risk for fatty liver disease-a UK Biobank sub-study, with an appendix of interesting cases. Abdom Radiol (NY) 2019; 44:72-84. [PMID: 30032383 PMCID: PMC6348264 DOI: 10.1007/s00261-018-1701-2] [Citation(s) in RCA: 49] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Purpose Corrected T1 (cT1) value is a novel MRI-based quantitative metric for assessing a composite of liver inflammation and fibrosis. It has been shown to distinguish between non-alcoholic fatty liver disease (NAFL) and non-alcoholic steatohepatitis. However, these studies were conducted in patients at high risk for liver disease. This study establishes the normal reference range of cT1 values for a large UK population, and assesses interactions of age and gender. Methods MR data were acquired on a 1.5 T system as part of the UK Biobank Imaging Enhancement study. Measures for Proton Density Fat Fraction and cT1 were calculated from the MRI data using a multiparametric MRI software application. Data that did not meet quality criteria were excluded from further analysis. Inter and intra-reader variability was estimated in a set of data. A cohort at low risk for NAFL was identified by excluding individuals with BMI ≥ 25 kg/m2 and PDFF ≥ 5%. Of the 2816 participants with data of suitable quality, 1037 (37%) were classified as at low risk. Results The cT1 values in the low-risk population ranged from 573 to 852 ms with a median of 666 ms and interquartile range from 643 to 694 ms. Iron correction of T1 was necessary in 36.5% of this reference population. Age and gender had minimal effect on cT1 values. Conclusion The majority of cT1 values are tightly clustered in a population at low risk for NAFL, suggesting it has the potential to serve as a new quantitative imaging biomarker for studies of liver health and disease.
Collapse
Affiliation(s)
- A Mojtahed
- Division of Abdominal Imaging, Massachusetts General Hospital, Boston, MA, USA.
| | | | | | - S Kin
- Perspectum Diagnostics, Oxford, UK
| | - H R Wilman
- Perspectum Diagnostics, Oxford, UK
- Department of Life Sciences, University of Westminster, London, UK
| | - A McKay
- Perspectum Diagnostics, Oxford, UK
| | - M Kelly
- Perspectum Diagnostics, Oxford, UK
| | | | - S Neubauer
- Perspectum Diagnostics, Oxford, UK
- Oxford Centre for Clinical Magnetic Resonance Research, University of Oxford, Oxford, UK
| | - E L Thomas
- Department of Life Sciences, University of Westminster, London, UK
| | - J D Bell
- Department of Life Sciences, University of Westminster, London, UK
| | | | - M Harisinghani
- Division of Abdominal Imaging, Massachusetts General Hospital, Boston, MA, USA
| |
Collapse
|
44
|
Chouhan MD, Taylor SA, Mookerjee RP. Multi-organ quantitative MRI for the assessment of liver disease - A whole much more than the sum of its parts. J Hepatol 2018; 69:996-998. [PMID: 30227985 DOI: 10.1016/j.jhep.2018.09.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Accepted: 09/05/2018] [Indexed: 12/04/2022]
Affiliation(s)
- Manil D Chouhan
- University College London (UCL) Centre for Medical Imaging, Division of Medicine, UCL, London, UK.
| | - Stuart A Taylor
- University College London (UCL) Centre for Medical Imaging, Division of Medicine, UCL, London, UK
| | - Rajeshwar P Mookerjee
- University College London (UCL) Institute for Liver and Digestive Health, Division of Medicine, UCL, London, UK
| |
Collapse
|
45
|
Cunha GM, Villela-Nogueira CA, Bergman A, Lobo Lopes FPP. Abbreviated mpMRI protocol for diffuse liver disease: a practical approach for evaluation and follow-up of NAFLD. Abdom Radiol (NY) 2018; 43:2340-2350. [PMID: 29450605 DOI: 10.1007/s00261-018-1504-5] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
AIM Multiparametric magnetic resonance imaging (mpMRI) may help determine the metabolic profile of patients with obesity and metabolic syndrome in addition to their clinical and laboratory biomarkers for diagnosis and monitoring. An abbreviated mpMRI protocol may be a faster, less-costly, and easier to perform alternative for the diagnosis, treatment, and follow-up of patients with NAFLD and for use in clinical trials. OBJECTIVE To evaluate an abbreviated mpMRI protocol tailored to analyze quantitative imaging features of patients with obesity and NAFLD and assess its use during treatment. METHODS This prospective study included patients with obesity and NAFLD to perform a quantitative analysis of liver fat and iron content, stiffness, as well as the visceral adipose tissue (VAT) during the course of a physical exercise-based treatment regimen. RESULTS Longitudinal improvements in imaging features were observed in patients with good response to treatment, in accordance with improvements in biochemical and anthropometric biomarkers. CONCLUSION An abbreviated mpMRI protocol consisting of liver fat and iron quantification, MR elastography, and VAT measurements is a feasible, less-costly, and accessible option for screening and monitoring of patients with obesity, NAFLD, and metabolic syndrome.
Collapse
Affiliation(s)
- Guilherme Moura Cunha
- Clínica de Diagnóstico por Imagem - CDPI/DASA, Av. Ataulfo de Paiva, 669, Leblon, Rio de Janeiro, 22440-032, Brazil.
| | - Cristiane A Villela-Nogueira
- Faculdade de Medicina, Departamento de Clínica Médica, Serviço de Hepatologia, Universidade Federal do Rio De Janeiro, UFRJ R. Prof. Rodolpho Paulo Rocco, 255 sala 9E16 - Cidade Universitária, Rio de Janeiro, 22440-032, Brazil
| | - Anke Bergman
- Instituto Nacional de Câncer (INCA), Rua André Cavalcanti, 37, Rio de Janeiro, 20231-050, Brazil
| | | |
Collapse
|
46
|
McDonald N, Eddowes PJ, Hodson J, Semple SIK, Davies NP, Kelly CJ, Kin S, Phillips M, Herlihy AH, Kendall TJ, Brown RM, Neil DAH, Hübscher SG, Hirschfield GM, Fallowfield JA. Multiparametric magnetic resonance imaging for quantitation of liver disease: a two-centre cross-sectional observational study. Sci Rep 2018; 8:9189. [PMID: 29907829 PMCID: PMC6003924 DOI: 10.1038/s41598-018-27560-5] [Citation(s) in RCA: 51] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Accepted: 05/29/2018] [Indexed: 01/06/2023] Open
Abstract
LiverMultiScan is an emerging diagnostic tool using multiparametric MRI to quantify liver disease. In a two-centre prospective validation study, 161 consecutive adult patients who had clinically-indicated liver biopsies underwent contemporaneous non-contrast multiparametric MRI at 3.0 tesla (proton density fat fraction (PDFF), T1 and T2* mapping), transient elastography (TE) and Enhanced Liver Fibrosis (ELF) test. Non-invasive liver tests were correlated with gold standard histothological measures. Reproducibility of LiverMultiScan was investigated in 22 healthy volunteers. Iron-corrected T1 (cT1), TE, and ELF demonstrated a positive correlation with hepatic collagen proportionate area (all p < 0·001). TE was superior to ELF and cT1 for predicting fibrosis stage. cT1 maintained good predictive accuracy for diagnosing significant fibrosis in cases with indeterminate ELF, but not for cases with indeterminate TE values. PDFF had high predictive accuracy for individual steatosis grades, with AUROCs ranging from 0.90-0.94. T2* mapping diagnosed iron accumulation with AUROC of 0.79 (95% CI: 0.67-0.92) and negative predictive value of 96%. LiverMultiScan showed excellent test/re-test reliability (coefficients of variation ranging from 1.4% to 2.8% for cT1). Overall failure rates for LiverMultiScan, ELF and TE were 4.3%, 1.9% and 15%, respectively. LiverMultiScan is an emerging point-of-care diagnostic tool that is comparable with the established non-invasive tests for assessment of liver fibrosis, whilst at the same time offering a superior technical success rate and contemporaneous measurement of liver steatosis and iron accumulation.
Collapse
Affiliation(s)
- Natasha McDonald
- MRC/University of Edinburgh Centre for Inflammation Research, Queen's Medical Research Institute, Edinburgh, EH16 4TJ, UK
| | - Peter J Eddowes
- Centre for Liver Research and NIHR Birmingham BRC, University of Birmingham, Birmingham, B15 2TT, UK
- NIHR Nottingham BRC, Nottingham University Hospitals NHS Trust and the University of Nottingham, Nottingham, NG1 5DU, UK
| | - James Hodson
- Institute of Translational Medicine, University Hospitals Birmingham NHS Foundation Trust, Birmingham, B15 2TT, UK
| | - Scott I K Semple
- BHF/University of Edinburgh Centre for Cardiovascular Science, Queen's Medical Research Institute, Edinburgh, EH16 4TJ, UK
| | - Nigel P Davies
- Imaging and Medical Physics, University Hospitals Birmingham NHS Foundation Trust, Birmingham, B15 2TH, UK
| | - Catherine J Kelly
- Perspectum Diagnostics Ltd., Oxford Centre for Innovation, Oxford, OX1 1BY, UK
| | - Stella Kin
- Perspectum Diagnostics Ltd., Oxford Centre for Innovation, Oxford, OX1 1BY, UK
| | - Miranda Phillips
- Perspectum Diagnostics Ltd., Oxford Centre for Innovation, Oxford, OX1 1BY, UK
| | - Amy H Herlihy
- Perspectum Diagnostics Ltd., Oxford Centre for Innovation, Oxford, OX1 1BY, UK
| | - Timothy J Kendall
- MRC/University of Edinburgh Centre for Inflammation Research, Queen's Medical Research Institute, Edinburgh, EH16 4TJ, UK
- Division of Pathology, Royal Infirmary of Edinburgh, Edinburgh, EH16 4SA, UK
| | - Rachel M Brown
- Department of Cellular Pathology, Queen Elizabeth Hospital, Birmingham, B15 2TH, UK
| | - Desley A H Neil
- Department of Cellular Pathology, Queen Elizabeth Hospital, Birmingham, B15 2TH, UK
| | - Stefan G Hübscher
- Centre for Liver Research and NIHR Birmingham BRC, University of Birmingham, Birmingham, B15 2TT, UK
- Department of Cellular Pathology, Queen Elizabeth Hospital, Birmingham, B15 2TH, UK
| | - Gideon M Hirschfield
- Centre for Liver Research and NIHR Birmingham BRC, University of Birmingham, Birmingham, B15 2TT, UK
| | - Jonathan A Fallowfield
- MRC/University of Edinburgh Centre for Inflammation Research, Queen's Medical Research Institute, Edinburgh, EH16 4TJ, UK.
| |
Collapse
|
47
|
Ostovaneh MR, Ambale-Venkatesh B, Fuji T, Bakhshi H, Shah R, Murthy VL, Tracy RP, Guallar E, Wu CO, Bluemke DA, Lima JAC. Association of Liver Fibrosis With Cardiovascular Diseases in the General Population: The Multi-Ethnic Study of Atherosclerosis (MESA). Circ Cardiovasc Imaging 2018; 11:e007241. [PMID: 29523555 PMCID: PMC5846116 DOI: 10.1161/circimaging.117.007241] [Citation(s) in RCA: 61] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2017] [Accepted: 01/05/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND The association of cardiovascular diseases (CVD) with liver fibrosis is poorly understood. We aim to assess the association of liver fibrosis by T1-mapping magnetic resonance imaging and CVD in MESA (Multi-Ethnic Study of Atherosclerosis). METHODS AND RESULTS MESA enrolled 6814 participants free of clinical CVD at baseline (2000-2002). A subsample of participants underwent T1-mapping magnetic resonance imaging 10 years after the baseline (Y10 MESA exam, 2010-2012). Liver T1 maps were generated avoiding vessels and biliary ducts from which native T1 (n=2087) and extracellular volume fraction (ECV, n=1234) were determined. Higher ECV and native T1 were indicators of liver fibrosis. Linear regression analysis evaluated the cross-sectional relationship between liver native T1 and ECV at Y10 MESA exam with a history of CVD events (atrial fibrillation, heart failure, and coronary heart disease [CHD]). Of the 2087 participants (68.7±9.1 years; 46% females), 153 had prior CVD events (78 atrial fibrillation, 25 heart failure, and 78 CHD). History of CVD events was associated with 18.5 ms higher liver native T1 (P<0.001) and 1.4% greater ECV (P=0.06). Prior atrial fibrillation was related to higher liver native T1 (β=21.1; P=0.001) and greater ECV (β=2.2; P=0.02), whereas previous heart failure was associated with greater liver ECV (β=4.1; P=0.02). There was also a relationship of prior CHD with liver native T1 (β=13; P=0.05) and ECV (β=1.9; P=0.05), which was attenuated by adjustment for coronary artery calcium score (β=7.1 and 1.6; P=0.37 and 0.13, respectively). CONCLUSIONS Liver fibrosis by T1-mapping magnetic resonance imaging is associated with history of heart failure, atrial fibrillation, and CHD in a multiethnic cohort. The association of liver fibrosis and CHD is at least in part mediated by atherosclerosis.
Collapse
Affiliation(s)
| | - Bharath Ambale-Venkatesh
- From the Depatrment of Cardiology (M.R.O., T.F., H.B., E.G., J.A.C.L.) and the Department of Radiology (B.A.V.), Johns Hopkins University, Baltimore, MD; Department of Medicine, Harvard University, Boston, MA (R.S.); Department of Medicine, University of Michigan, Ann Arbor (V.L.M.); Department of Pathology and Laboratory Medicine, University of Vermont, Colchester (R.P.T.); National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD (C.O.W.); and Department of Radiology, University of Wisconsin, Madison (D.A.B.).
| | | | | | | | | | | | | | - Colin O. Wu
- National Institutes of Health, Bethesda MD, USA
| | | | | |
Collapse
|
48
|
Tamada D, Wakayama T, Onishi H, Motosugi U. Multiparameter estimation using multi-echo spoiled gradient echo with variable flip angles and multicontrast compressed sensing. Magn Reson Med 2018; 80:1546-1555. [PMID: 29476555 DOI: 10.1002/mrm.27151] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2017] [Revised: 01/10/2018] [Accepted: 02/05/2018] [Indexed: 12/20/2022]
Abstract
PURPOSE To develop multiparameter mapping including T1 , R2*, and proton density fat fraction with a single breath-hold to evaluate liver disease and liver function. METHODS A 6-echo spoiled gradient-echo sequence with dual flip angles was used to acquire a 12-set MRI volume data set. To shorten the scan time, undersampling and multicontrast compressed-sensing reconstruction were used. The scan time was 18 seconds. R2* and proton density fat fraction mapping were achieved by using the iterative least-squares method. T1 mapping was estimated using driven equilibrium single-pulse observation of T1 . Quantitative values were validated by performing phantom and volunteer studies. RESULTS Statistical analysis showed that the quantitative values measured using the proposed methods agreed with those measured using conventional methods. T1 values of water proton measured by the proposed method in phantom and volunteer studies were in good agreement with those by MRS. CONCLUSION The results showed that accurate quantitative mapping of T1 , R2*, and proton density fat fraction with a single breath-hold was achieved using our approach.
Collapse
Affiliation(s)
- Daiki Tamada
- Department of Radiology, University of Yamanashi, Yamanshi, Japan
| | | | - Hiroshi Onishi
- Department of Radiology, University of Yamanashi, Yamanshi, Japan
| | - Utaroh Motosugi
- Department of Radiology, University of Yamanashi, Yamanshi, Japan
| |
Collapse
|
49
|
Messroghli DR, Moon JC, Ferreira VM, Grosse-Wortmann L, He T, Kellman P, Mascherbauer J, Nezafat R, Salerno M, Schelbert EB, Taylor AJ, Thompson R, Ugander M, van Heeswijk RB, Friedrich MG. Clinical recommendations for cardiovascular magnetic resonance mapping of T1, T2, T2* and extracellular volume: A consensus statement by the Society for Cardiovascular Magnetic Resonance (SCMR) endorsed by the European Association for Cardiovascular Imaging (EACVI). J Cardiovasc Magn Reson 2017; 19:75. [PMID: 28992817 PMCID: PMC5633041 DOI: 10.1186/s12968-017-0389-8] [Citation(s) in RCA: 1034] [Impact Index Per Article: 147.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2017] [Accepted: 09/25/2017] [Indexed: 12/14/2022] Open
Abstract
Parametric mapping techniques provide a non-invasive tool for quantifying tissue alterations in myocardial disease in those eligible for cardiovascular magnetic resonance (CMR). Parametric mapping with CMR now permits the routine spatial visualization and quantification of changes in myocardial composition based on changes in T1, T2, and T2*(star) relaxation times and extracellular volume (ECV). These changes include specific disease pathways related to mainly intracellular disturbances of the cardiomyocyte (e.g., iron overload, or glycosphingolipid accumulation in Anderson-Fabry disease); extracellular disturbances in the myocardial interstitium (e.g., myocardial fibrosis or cardiac amyloidosis from accumulation of collagen or amyloid proteins, respectively); or both (myocardial edema with increased intracellular and/or extracellular water). Parametric mapping promises improvements in patient care through advances in quantitative diagnostics, inter- and intra-patient comparability, and relatedly improvements in treatment. There is a multitude of technical approaches and potential applications. This document provides a summary of the existing evidence for the clinical value of parametric mapping in the heart as of mid 2017, and gives recommendations for practical use in different clinical scenarios for scientists, clinicians, and CMR manufacturers.
Collapse
Affiliation(s)
- Daniel R. Messroghli
- Department of Internal Medicine and Cardiology, Deutsches Herzzentrum Berlin, Berlin, Germany
- Department of Internal Medicine and Cardiology, Charité Universitätsmedizin Berlin, Augustenburger Platz 1, 13353 Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), partner site Berlin, Augustenburger Platz 1, 13353 Berlin, Germany
| | - James C. Moon
- University College London and Barts Heart Centre, London, UK
| | - Vanessa M. Ferreira
- Oxford Centre for Clinical Magnetic Resonance Research, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK
| | - Lars Grosse-Wortmann
- Division of Cardiology in the Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, ON Canada
| | - Taigang He
- Cardiovascular Science Research Centre, St George’s, University of London, London, UK
| | | | - Julia Mascherbauer
- Department of Internal Medicine II, Division of Cardiology, Vienna, Austria
| | - Reza Nezafat
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, USA
| | - Michael Salerno
- Departments of Medicine Cardiology Division, Radiology and Medical Imaging, and Biomedical Engineering, University of Virginia Health System, Charlottesville, VA USA
| | - Erik B. Schelbert
- Department of Medicine, University of Pittsburgh School of Medicine, Pittsburgh, PA USA
- UPMC Cardiovascular Magnetic Resonance Center, Heart and Vascular Institute, Pittsburgh, PA USA
- Clinical and Translational Science Institute, University of Pittsburgh, Pittsburgh, PA USA
| | - Andrew J. Taylor
- The Alfred Hospital, Baker Heart and Diabetes Institute, Melbourne, Australia
| | - Richard Thompson
- Department of Biomedical Engineering, University of Alberta, Edmonton, Canada
| | - Martin Ugander
- Department of Clinical Physiology, Karolinska Institutet, Karolinska University Hospital, Stockholm, Sweden
| | - Ruud B. van Heeswijk
- Department of Radiology, Lausanne University Hospital (CHUV) and Lausanne University (UNIL), Lausanne, Switzerland
| | - Matthias G. Friedrich
- Departments of Medicine and Diagnostic Radiology, McGill University, Montréal, Québec Canada
- Department of Medicine, Heidelberg University, Heidelberg, Germany
- Département de radiologie, Université de Montréal, Montréal, Québec Canada
- Departments of Cardiac Sciences and Radiology, University of Calgary, Calgary, Canada
| |
Collapse
|
50
|
Cox EF, Buchanan CE, Bradley CR, Prestwich B, Mahmoud H, Taal M, Selby NM, Francis ST. Multiparametric Renal Magnetic Resonance Imaging: Validation, Interventions, and Alterations in Chronic Kidney Disease. Front Physiol 2017; 8:696. [PMID: 28959212 PMCID: PMC5603702 DOI: 10.3389/fphys.2017.00696] [Citation(s) in RCA: 84] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2017] [Accepted: 08/30/2017] [Indexed: 12/15/2022] Open
Abstract
Background: This paper outlines a multiparametric renal MRI acquisition and analysis protocol to allow non-invasive assessment of hemodynamics (renal artery blood flow and perfusion), oxygenation (BOLD T2*), and microstructure (diffusion, T1 mapping). Methods: We use our multiparametric renal MRI protocol to provide (1) a comprehensive set of MRI parameters [renal artery and vein blood flow, perfusion, T1, T2*, diffusion (ADC, D, D*, fp), and total kidney volume] in a large cohort of healthy participants (127 participants with mean age of 41 ± 19 years) and show the MR field strength (1.5 T vs. 3 T) dependence of T1 and T2* relaxation times; (2) the repeatability of multiparametric MRI measures in 11 healthy participants; (3) changes in MRI measures in response to hypercapnic and hyperoxic modulations in six healthy participants; and (4) pilot data showing the application of the multiparametric protocol in 11 patients with Chronic Kidney Disease (CKD). Results: Baseline measures were in-line with literature values, and as expected, T1-values were longer at 3 T compared with 1.5 T, with increased T1 corticomedullary differentiation at 3 T. Conversely, T2* was longer at 1.5 T. Inter-scan coefficients of variation (CoVs) of T1 mapping and ADC were very good at <2.9%. Intra class correlations (ICCs) were high for cortex perfusion (0.801), cortex and medulla T1 (0.848 and 0.997 using SE-EPI), and renal artery flow (0.844). In response to hypercapnia, a decrease in cortex T2* was observed, whilst no significant effect of hyperoxia on T2* was found. In CKD patients, renal artery and vein blood flow, and renal perfusion was lower than for healthy participants. Renal cortex and medulla T1 was significantly higher in CKD patients compared to healthy participants, with corticomedullary T1 differentiation reduced in CKD patients compared to healthy participants. No significant difference was found in renal T2*. Conclusions: Multiparametric MRI is a powerful technique for the assessment of changes in structure, hemodynamics, and oxygenation in a single scan session. This protocol provides the potential to assess the pathophysiological mechanisms in various etiologies of renal disease, and to assess the efficacy of drug treatments.
Collapse
Affiliation(s)
- Eleanor F Cox
- Sir Peter Mansfield Imaging Centre, University of NottinghamNottingham, United Kingdom
| | - Charlotte E Buchanan
- Sir Peter Mansfield Imaging Centre, University of NottinghamNottingham, United Kingdom
| | - Christopher R Bradley
- Sir Peter Mansfield Imaging Centre, University of NottinghamNottingham, United Kingdom
| | - Benjamin Prestwich
- Sir Peter Mansfield Imaging Centre, University of NottinghamNottingham, United Kingdom
| | - Huda Mahmoud
- Centre for Kidney Research and Innovation, Royal Derby Hospital, University of NottinghamDerby, United Kingdom
| | - Maarten Taal
- Centre for Kidney Research and Innovation, Royal Derby Hospital, University of NottinghamDerby, United Kingdom
| | - Nicholas M Selby
- Centre for Kidney Research and Innovation, Royal Derby Hospital, University of NottinghamDerby, United Kingdom
| | - Susan T Francis
- Sir Peter Mansfield Imaging Centre, University of NottinghamNottingham, United Kingdom
| |
Collapse
|