1
|
Lan C, Peng Y, Zuo H, Pei J, Li Y, Zhang T, Wu H, Du L, Zeng C, Zhao H, Chen X, Gao H. Spatially lipidomic characterization of patient-derived organoids by whole-mount autofocusing SMALDI mass spectrometry imaging. Anal Chim Acta 2024; 1325:342989. [PMID: 39244298 DOI: 10.1016/j.aca.2024.342989] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Revised: 07/06/2024] [Accepted: 07/17/2024] [Indexed: 09/09/2024]
Abstract
BACKGROUND Patient-derived organoids (PDOs) are multi-cellular cultures with specific three-dimensional (3D) structures. Tumor organoids (TOs) offer a personalized perspective for assessing treatment response. However, the presence of normal organoid (NO) residuals poses a potential threat to their utility for personalized medicine. There is a crucial need for an effective platform capable of distinguishing between TO and NO in cancer organoid cultures. RESULTS We introduced a whole-mount (WM) preparation protocol for in-situ visualization of the lipidomic distribution of organoids. To assess the efficacy of this method, nine breast cancer organoids (BCOs) and six normal breast organoids (NBOs) were analyzed. Poly-l-lysine (PLL) coated slides, equipped with 12 well chambers, were utilized as a carrier for the high-throughput analysis of PDOs. Optimizing the fixation time to 30 min, preserved the integrity of organoids and the fidelity of lipid compounds. The PDOs derived from the same organoid lines exhibited similar lipidomic profiles. BCOs and NBOs were obviously distinguished based on their lipidomic signatures detected by WM autofocusing (AF) scanning microprobe matrix-assisted laser desorption/ionization (SMALDI) mass spectrometry imaging (MSI). SIGNIFICANCE A whole-mount (WM) preparation protocol was developed to visualize lipidomic distributions of the organoids' surface. Using poly-l-lysine coated slides for high-throughput analysis, the method preserved organoid integrity and distinguished breast cancer organoids (BCOs) from normal breast organoids (NBOs) based on their unique lipidomic profiles using autofocusing scanning microprobe matrix-assisted laser desorption/ionization (SMALDI) mass spectrometry imaging.
Collapse
Affiliation(s)
- Chunyan Lan
- National Human Genetic Resources Center, National Research Institute for Family Planning, Beijing, 100081, China; Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100730, China
| | - Ying Peng
- Department of General Surgery, Peking University Third Hospital, Beijing, 100191, China
| | - Hengtong Zuo
- Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100730, China; State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Beijing, 100050, China
| | - Jianying Pei
- National Human Genetic Resources Center, National Research Institute for Family Planning, Beijing, 100081, China; Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100730, China
| | - Yue Li
- National Human Genetic Resources Center, National Research Institute for Family Planning, Beijing, 100081, China
| | - Ting Zhang
- Beijing Advanced Innovation Centre for Biomedical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Chinese Education Ministry, School of Biological Science and Medical Engineering, Beihang University, Beijing, 10083, China
| | - Hainan Wu
- Beijing Advanced Innovation Centre for Biomedical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Chinese Education Ministry, School of Biological Science and Medical Engineering, Beihang University, Beijing, 10083, China
| | - Liyuan Du
- Create (Beijing) Technology Co., Limited, Beijing, 102600, China
| | - Chang Zeng
- Create (Beijing) Technology Co., Limited, Beijing, 102600, China
| | - Hongmei Zhao
- Department of General Surgery, Peking University Third Hospital, Beijing, 100191, China
| | - Xiaofang Chen
- Beijing Advanced Innovation Centre for Biomedical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Chinese Education Ministry, School of Biological Science and Medical Engineering, Beihang University, Beijing, 10083, China
| | - Huafang Gao
- National Human Genetic Resources Center, National Research Institute for Family Planning, Beijing, 100081, China; Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100730, China.
| |
Collapse
|
2
|
Harvey DJ. Analysis of carbohydrates and glycoconjugates by matrix-assisted laser desorption/ionization mass spectrometry: An update for 2021-2022. MASS SPECTROMETRY REVIEWS 2024. [PMID: 38925550 DOI: 10.1002/mas.21873] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Revised: 02/05/2024] [Accepted: 02/12/2024] [Indexed: 06/28/2024]
Abstract
The use of matrix-assisted laser desorption/ionization (MALDI) mass spectrometry for the analysis of carbohydrates and glycoconjugates is a well-established technique and this review is the 12th update of the original article published in 1999 and brings coverage of the literature to the end of 2022. As with previous review, this review also includes a few papers that describe methods appropriate to analysis by MALDI, such as sample preparation, even though the ionization method is not MALDI. The review follows the same format as previous reviews. It is divided into three sections: (1) general aspects such as theory of the MALDI process, matrices, derivatization, MALDI imaging, fragmentation, quantification and the use of computer software for structural identification. (2) Applications to various structural types such as oligo- and polysaccharides, glycoproteins, glycolipids, glycosides and biopharmaceuticals, and (3) other general areas such as medicine, industrial processes, natural products and glycan synthesis where MALDI is extensively used. Much of the material relating to applications is presented in tabular form. MALDI is still an ideal technique for carbohydrate analysis, particularly in its ability to produce single ions from each analyte and advancements in the technique and range of applications show little sign of diminishing.
Collapse
|
3
|
McKenzie AT, Nnadi O, Slagell KD, Thorn EL, Farrell K, Crary JF. Fluid preservation in brain banking: a review. FREE NEUROPATHOLOGY 2024; 5:5-10. [PMID: 38690035 PMCID: PMC11058410 DOI: 10.17879/freeneuropathology-2024-5373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Accepted: 03/29/2024] [Indexed: 05/02/2024]
Abstract
Fluid preservation is nearly universally used in brain banking to store fixed tissue specimens for future research applications. However, the effects of long-term immersion on neural circuitry and biomolecules are not well characterized. As a result, there is a need to synthesize studies investigating fluid preservation of brain tissue. We searched PubMed and other databases to identify studies measuring the effects of fluid preservation in nervous system tissue. We categorized studies based on the fluid preservative used: formaldehyde solutions, buffer solutions, alcohol solutions, storage after tissue clearing, and cryoprotectant solutions. We identified 91 studies containing 197 independent observations of the effects of long-term storage on cellular morphology. Most studies did not report any significant alterations due to long-term storage. When present, the most frequent alteration was decreased antigenicity, commonly attributed to progressive crosslinking by aldehydes that renders biomolecules increasingly inaccessible over time. To build a mechanistic understanding, we discuss biochemical aspects of long-term fluid preservation. A subset of lipids appears to be chemical altered or extracted over time due to incomplete retention in the crosslinked gel. Alternative storage fluids mitigate the problem of antigen masking but have not been extensively characterized and may have other downsides. We also compare fluid preservation to cryopreservation, paraffin embedding, and resin embedding. Overall, existing evidence suggests that fluid preservation provides maintenance of neural architecture for decades, including precise structural details. However, to avoid the well-established problem of overfixation caused by storage in high concentration formaldehyde solutions, fluid preservation procedures can use an initial fixation step followed by an alternative long-term storage fluid. Further research is warranted on optimizing protocols and characterizing the generalizability of the storage artifacts that have been identified.
Collapse
Affiliation(s)
| | - Oge Nnadi
- Brain Preservation Foundation, Ashburn, Virginia, USA
| | - Kat D. Slagell
- Department of Neuroscience, Icahn School of Medicine at Mount Sinai, New York, New York, USA
- Friedman Brain Institute, Departments of Pathology, Neuroscience, and Artificial Intelligence & Human Health, Icahn School of Medicine at Mount Sinai, New York, New York, USA
- Neuropathology Brain Bank & Research Core and Ronald M. Loeb Center for Alzheimer's Disease, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Emma L. Thorn
- Department of Neuroscience, Icahn School of Medicine at Mount Sinai, New York, New York, USA
- Friedman Brain Institute, Departments of Pathology, Neuroscience, and Artificial Intelligence & Human Health, Icahn School of Medicine at Mount Sinai, New York, New York, USA
- Neuropathology Brain Bank & Research Core and Ronald M. Loeb Center for Alzheimer's Disease, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Kurt Farrell
- Department of Neuroscience, Icahn School of Medicine at Mount Sinai, New York, New York, USA
- Friedman Brain Institute, Departments of Pathology, Neuroscience, and Artificial Intelligence & Human Health, Icahn School of Medicine at Mount Sinai, New York, New York, USA
- Neuropathology Brain Bank & Research Core and Ronald M. Loeb Center for Alzheimer's Disease, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - John F. Crary
- Department of Neuroscience, Icahn School of Medicine at Mount Sinai, New York, New York, USA
- Friedman Brain Institute, Departments of Pathology, Neuroscience, and Artificial Intelligence & Human Health, Icahn School of Medicine at Mount Sinai, New York, New York, USA
- Neuropathology Brain Bank & Research Core and Ronald M. Loeb Center for Alzheimer's Disease, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| |
Collapse
|
4
|
Duivenvoorden AM, Claes BSR, van der Vloet L, Lubbers T, Glunde K, Olde Damink SWM, Heeren RMA, Lenaerts K. Lipidomic Phenotyping Of Human Small Intestinal Organoids Using Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Imaging. Anal Chem 2023; 95:18443-18450. [PMID: 38060464 PMCID: PMC10733903 DOI: 10.1021/acs.analchem.3c03543] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 10/29/2023] [Accepted: 11/06/2023] [Indexed: 12/20/2023]
Abstract
In the past decade, interest in organoids for biomedical research has surged, resulting in a higher demand for advanced imaging techniques. Traditional specimen embedding methods pose challenges, such as analyte delocalization and histological assessment. Here, we present an optimized sample preparation approach utilizing an Epredia M-1 cellulose-based embedding matrix, which preserves the structural integrity of fragile small intestinal organoids (SIOs). Additionally, background interference (delocalization of analytes, nonspecific (histological) staining, matrix ion clusters) was minimized, and we demonstrate the compatibility with matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI). With our approach, we can conduct label-free lipid imaging at the single-cell level, thereby yielding insights into the spatial distribution of lipids in both positive and negative ion modes. Moreover, M-1 embedding allows for an improved coregistration with histological and immunohistochemical (IHC) stainings, including MALDI-IHC, facilitating combined untargeted and targeted spatial information. Applying this approach, we successfully phenotyped crypt-like (CL) and villus-like (VL) SIOs, revealing that PE 36:2 [M - H]- (m/z 742.5) and PI 38:4 [M - H]- (m/z 885.5) display higher abundance in CL organoids, whereas PI 36:1 [M - H]- (m/z 863.6) was more prevalent in VL organoids. Our findings demonstrate the utility of M-1 embedding for advancing organoid research and unraveling intricate biological processes within these in vitro models.
Collapse
Affiliation(s)
- Annet
A. M. Duivenvoorden
- Department
of Surgery, NUTRIM School of Nutrition and Translational Research
in Metabolism, Maastricht University, 6229 ER Maastricht, The Netherlands
| | - Britt S. R. Claes
- The
Maastricht MultiModal Molecular Imaging (M4i) Institute, Division
of Imaging Mass Spectrometry (IMS), Maastricht
University, 6229 ER Maastricht, The Netherlands
| | - Laura van der Vloet
- The
Maastricht MultiModal Molecular Imaging (M4i) Institute, Division
of Imaging Mass Spectrometry (IMS), Maastricht
University, 6229 ER Maastricht, The Netherlands
| | - Tim Lubbers
- Department
of Surgery, Maastricht University Medical
Center+ (MUMC+), 6229 HX Maastricht, The Netherlands
- GROW
– School for Oncology and Developmental Biology, Maastricht University Medical Center+ (MUMC+), 6229 HX Maastricht, The Netherlands
| | - Kristine Glunde
- The
Russell H. Morgan Department of Radiology and Radiological Science,
Division of Cancer Imaging Research, The
Johns Hopkins School of Medicine, Baltimore, Maryland 21205, United States
- The
Sidney
Kimmel Comprehensive Cancer Center, The
Johns Hopkins School of Medicine, Baltimore, Maryland 21205, United States
- Department
of Biological Chemistry, The Johns Hopkins
School of Medicine, Baltimore, Maryland 21205, United States
| | - Steven W. M. Olde Damink
- Department
of Surgery, NUTRIM School of Nutrition and Translational Research
in Metabolism, Maastricht University, 6229 ER Maastricht, The Netherlands
- Department
of Surgery, Maastricht University Medical
Center+ (MUMC+), 6229 HX Maastricht, The Netherlands
- Department
of General, Gastrointestinal, Hepatobiliary and Transplant Surgery, RWTH Aachen University Hospital, 52074 Aachen, Germany
| | - Ron M. A. Heeren
- The
Maastricht MultiModal Molecular Imaging (M4i) Institute, Division
of Imaging Mass Spectrometry (IMS), Maastricht
University, 6229 ER Maastricht, The Netherlands
| | - Kaatje Lenaerts
- Department
of Surgery, NUTRIM School of Nutrition and Translational Research
in Metabolism, Maastricht University, 6229 ER Maastricht, The Netherlands
| |
Collapse
|
5
|
Anderson DM, Kotnala A, Migas LG, Patterson NH, Tideman L, Cao D, Adhikari B, Messinger JD, Ach T, Tortorella S, Van de Plas R, Curcio CA, Schey KL. Lysolipids are prominent in subretinal drusenoid deposits, a high-risk phenotype in age-related macular degeneration. FRONTIERS IN OPHTHALMOLOGY 2023; 3:1258734. [PMID: 38186747 PMCID: PMC10769005 DOI: 10.3389/fopht.2023.1258734] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2024]
Abstract
Introduction Age related macular degeneration (AMD) causes legal blindness worldwide, with few therapeutic targets in early disease and no treatments for 80% of cases. Extracellular deposits, including drusen and subretinal drusenoid deposits (SDD; also called reticular pseudodrusen), disrupt cone and rod photoreceptor functions and strongly confer risk for advanced disease. Due to the differential cholesterol composition of drusen and SDD, lipid transfer and cycling between photoreceptors and support cells are candidate dysregulated pathways leading to deposit formation. The current study explores this hypothesis through a comprehensive lipid compositional analysis of SDD. Methods Histology and transmission electron microscopy were used to characterize the morphology of SDD. Highly sensitive tools of imaging mass spectrometry (IMS) and nano liquid chromatography tandem mass spectrometry (nLC-MS/MS) in positive and negative ion modes were used to spatially map and identify SDD lipids, respectively. An interpretable supervised machine learning approach was utilized to compare the lipid composition of SDD to regions of uninvolved retina across 1873 IMS features and to automatically discern candidate markers for SDD. Immunohistochemistry (IHC) was used to localize secretory phospholipase A2 group 5 (PLA2G5). Results Among the 1873 detected features in IMS data, three lipid classes, including lysophosphatidylcholine (LysoPC), lysophosphatidylethanolamine (LysoPE) and lysophosphatidic acid (LysoPA) were observed nearly exclusively in SDD while presumed precursors, including phosphatidylcholine (PC), phosphatidylethanolamine (PE) and phosphatidic acid (PA) lipids were detected in SDD and adjacent photoreceptor outer segments. Molecular signals specific to SDD were found in central retina and elsewhere. IHC results indicated abundant PLA2G5 in photoreceptors and retinal pigment epithelium (RPE). Discussion The abundance of lysolipids in SDD implicates lipid remodeling or degradation in deposit formation, consistent with ultrastructural evidence of electron dense lipid-containing structures distinct from photoreceptor outer segment disks and immunolocalization of secretory PLA2G5 in photoreceptors and RPE. Further studies are required to understand the role of lipid signals observed in and around SDD.
Collapse
Affiliation(s)
| | - Ankita Kotnala
- Department of Biochemistry, Vanderbilt University, Nashville TN
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham AL
| | - Lukasz G. Migas
- Delft Center for Systems and Control (DCSC), Delft University of Technology, Delft, Netherlands
| | | | - Léonore Tideman
- Delft Center for Systems and Control (DCSC), Delft University of Technology, Delft, Netherlands
| | - Dongfeng Cao
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham AL
| | - Bibek Adhikari
- Vision Science Graduate Program, University of Alabama at Birmingham, Birmingham AL
| | - Jeffrey D. Messinger
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham AL
| | - Thomas Ach
- Department of Ophthalmology, University Hospital Bonn, Bonn, Germany
| | - Sara Tortorella
- Molecular Horizon Srl, Via Montelino 30, 06084 Bettona, Perugia, Italy
| | - Raf Van de Plas
- Department of Biochemistry, Vanderbilt University, Nashville TN
- Delft Center for Systems and Control (DCSC), Delft University of Technology, Delft, Netherlands
| | - Christine A. Curcio
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham AL
| | - Kevin L. Schey
- Department of Biochemistry, Vanderbilt University, Nashville TN
| |
Collapse
|
6
|
Wang MF, Ritter MM, Kullman SW, Muddiman DC. Comparative analysis of sucrose-embedding for whole-body zebrafish MSI by IR-MALDESI. Anal Bioanal Chem 2023; 415:6389-6398. [PMID: 37640826 PMCID: PMC11132179 DOI: 10.1007/s00216-023-04914-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Revised: 08/13/2023] [Accepted: 08/15/2023] [Indexed: 08/31/2023]
Abstract
Infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging (IR-MALDESI) conventionally utilizes fresh-frozen biological tissues with an ice matrix to improve the detection of analytes. Sucrose-embedding with paraformaldehyde fixation has demonstrated feasibility as an alternative matrix for analysis by IR-MALDESI by preserving tissue features and enhancing ionization of lipids. However, investigating multi-organ systems provides broader context for a biological study and can elucidate more information about a disease state as opposed to a single organ. Danio rerio, or zebrafish, are model organisms for various disease states and can be imaged as a multi-organ sample to analyze morphological and metabolomic preservation as a result of sample preparation. Herein, whole-body zebrafish were imaged to compare sucrose-embedding with paraformaldehyde fixation against conventional fresh-frozen sample preparation. Serial sections were analyzed with and without an ice matrix to evaluate if sucrose functions as an alternative energy-absorbing matrix for IR-MALDESI applications across whole-body tissues. The resulting four conditions were compared in terms of total putative lipid annotations and category diversity, coverage across the entire m/z range, and ion abundance. Ultimately, sucrose-embedded zebrafish had an increase in putative lipid annotations for the combination of putative annotations with and without the application of an ice matrix relative to fresh-frozen tissues which require the application of an ice matrix. Upon the use of an ice matrix, a greater number of high mass putative lipid annotations (e.g., glycerophospholipids, glycerolipids, and sphingolipids) were identified. Conversely, without an ice matrix, sucrose-embedded sections elucidated more putative annotations in lower molecular weight lipids, including fatty acyls and sterol lipids. Similar to the mouse brain model, sucrose-embedding increased putative lipid annotation and abundance for whole-body zebrafish.
Collapse
Affiliation(s)
- Mary F Wang
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
| | - Morgan M Ritter
- Department of Biological Sciences, North Carolina State University, Raleigh, NC, USA
- Toxicology Program, North Carolina State University, Raleigh, NC, USA
| | - Seth W Kullman
- Department of Biological Sciences, North Carolina State University, Raleigh, NC, USA
- Toxicology Program, North Carolina State University, Raleigh, NC, USA
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA.
| |
Collapse
|
7
|
Avard RC, Broad ML, Zandkarimi F, Devanny AJ, Hammer JL, Yu K, Guzman A, Kaufman LJ. DISC-3D: dual-hydrogel system enhances optical imaging and enables correlative mass spectrometry imaging of invading multicellular tumor spheroids. Sci Rep 2023; 13:12383. [PMID: 37524722 PMCID: PMC10390472 DOI: 10.1038/s41598-023-38699-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Accepted: 07/13/2023] [Indexed: 08/02/2023] Open
Abstract
Multicellular tumor spheroids embedded in collagen I matrices are common in vitro systems for the study of solid tumors that reflect the physiological environment and complexities of the in vivo environment. While collagen I environments are physiologically relevant and permissive of cell invasion, studying spheroids in such hydrogels presents challenges to key analytical assays and to a wide array of imaging modalities. While this is largely due to the thickness of the 3D hydrogels that in other samples can typically be overcome by sectioning, because of their highly porous nature, collagen I hydrogels are very challenging to section, especially in a manner that preserves the hydrogel network including cell invasion patterns. Here, we describe a novel method for preparing and cryosectioning invasive spheroids in a two-component (collagen I and gelatin) matrix, a technique we term dual-hydrogel in vitro spheroid cryosectioning of three-dimensional samples (DISC-3D). DISC-3D does not require cell fixation, preserves the architecture of invasive spheroids and their surroundings, eliminates imaging challenges, and allows for use of techniques that have infrequently been applied in three-dimensional spheroid analysis, including super-resolution microscopy and mass spectrometry imaging.
Collapse
Affiliation(s)
- Rachel C Avard
- Department of Chemistry, Columbia University, New York, NY, 10027, USA
| | - Megan L Broad
- Department of Chemistry, Columbia University, New York, NY, 10027, USA
- Department of Chemistry, Cardiff University, Cardiff, CF10 3AT, Wales, UK
| | | | | | - Joseph L Hammer
- Department of Chemistry, Columbia University, New York, NY, 10027, USA
| | - Karen Yu
- Department of Chemistry, Columbia University, New York, NY, 10027, USA
- Department of Physics, Columbia University, New York, NY, 10027, USA
| | - Asja Guzman
- Department of Biological Sciences, Columbia University, New York, NY, 10027, USA
| | - Laura J Kaufman
- Department of Chemistry, Columbia University, New York, NY, 10027, USA.
| |
Collapse
|
8
|
Simon R, Jentsch M, Karimimousivandi P, Cao D, Messinger JD, Meller D, Curcio CA, Hammer M. Prolonged Lifetimes of Histologic Autofluorescence in Ectopic Retinal Pigment Epithelium in Age-Related Macular Degeneration. Invest Ophthalmol Vis Sci 2022; 63:5. [PMID: 36469025 PMCID: PMC9730734 DOI: 10.1167/iovs.63.13.5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Purpose The purpose of this study was to investigate histologic autofluorescence lifetimes and spectra of retinal pigment epithelium (RPE) on the transition from normal aging to RPE activation and migration in age-related macular degeneration (AMD). Methods Autofluorescence lifetimes and spectra of 9 donor eyes were analyzed in cryosections by means of 2-photon excited fluorescence at 960 nm. Spectra were detected at 483 to 665 nm. Lifetimes were measured using time-correlated single photon counting in 2 spectral channels: 500 to 550 nm (short-wavelength spectral channel [SSC]) and 550 to 700 nm (long-wavelength spectral channel [LSC]). Fluorescence decays over time were approximated by a series of three exponential functions. The amplitude-weighted mean fluorescence lifetime was determined. Markers for retinoid activity (RPE65) and immune function (CD68) were immunolocalized in selected neighboring sections. Results We identified 9 RPE morphology phenotypes resulting in 399 regions of interest (ROIs) for spectral and 497 ROIs for lifetime measurements. RPE dysmorphia results in a shorter wavelength peak of spectral emission: normal aging versus RPE migrated into the retina (intraELM) = 601.7 (9.5) nm versus 581.6 (7.3) nm, P < 0.001, whereas autofluorescence lifetimes increase: normal aging versus intraELM: SSC 180 (44) picosecond (ps) versus 320 (86) ps, P < 0.001; and LSC 250 (55) ps versus 441 (76) ps, P < 0.001. Ectopic RPE within the neurosensory retina is strongly CD68 positive and RPE65 negative. Conclusions In the process of RPE degeneration, comprising different steps of dysmorphia and migration, lengthening of autofluorescence lifetimes and a hypsochromic shift of emission spectra can be observed. These autofluorescence changes might provide early biomarkers for AMD progression and contribute to our understanding of RPE-driven pathology.
Collapse
Affiliation(s)
- Rowena Simon
- Department of Ophthalmology, University Hospital Jena, Jena, Germany
| | - Marius Jentsch
- Department of Ophthalmology, University Hospital Jena, Jena, Germany
| | | | - Dongfeng Cao
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, United States
| | - Jeffrey D Messinger
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, United States
| | - Daniel Meller
- Department of Ophthalmology, University Hospital Jena, Jena, Germany
| | - Christine A Curcio
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, United States
| | - Martin Hammer
- Department of Ophthalmology, University Hospital Jena, Jena, Germany.,Center for Medical Optics and Photonics, University of Jena, Jena, Germany
| |
Collapse
|