Wu LC, Hsieh YY, Hsu TS, Liu PY, Tsuang FY, Kuo YJ, Chen CH, Van Huynh T, Chiang CJ. 3D-printed porous titanium suture anchor: a rabbit lateral femoral condyle model. BMC Musculoskelet Disord 2024; 25:559. [PMID: 39026178 PMCID: PMC11256369 DOI: 10.1186/s12891-024-07666-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Accepted: 07/05/2024] [Indexed: 07/20/2024] Open
Abstract
BACKGROUND The inclusion of a connecting path in a porous implant can promote nutrient diffusion to cells and enhance bone ingrowth. Consequently, this study aimed to evaluate the biomechanical, radiographic, and histopathological performance of a novel 3D-printed porous suture anchor in a rabbit femur model. METHODS Three test groups were formed based on the type of suture anchor (SA): Commercial SA (CSA, Group A, n = 20), custom solid SA (CSSA, Group B, n = 20), and custom porous SA (CPSA, Group C, n = 20). The SAs were implanted in the lateral femoral condyle of the right leg in each rabbit. The rabbits (New Zealand white rabbits, male, mean body weight of 2.8 ± 0.5 kg, age 8 months) underwent identical treatment and were randomized into experimental and control groups via computer-generated randomization. Five rabbits (10 femoral condyles) were euthanized at 0, 4, 8, and 12 weeks post-implantation for micro-CT, histological analysis, and biomechanical testing. RESULTS At 12 weeks, the CPSA showed a higher BV/TV (median 0.7301, IQR 0.7276-0.7315) than the CSSA and CSA. The histological analysis showed mineralized osteocytes near the SA. At 4 weeks, new bone was observed around the CPSA and had penetrated its porous structure. By 12 weeks, there was no significant difference in ultimate failure load between the CSA and CPSA. CONCLUSIONS We demonstrated that the innovative 3D-printed porous suture anchor exhibited comparable pullout strength to conventional threaded suture anchors at the 12-week postoperative time-point period. Furthermore, our porous anchor design enhanced new bone formation and facilitated bone growth into the implant structure, resulting in improved biomechanical stability.
Collapse
Affiliation(s)
- Lien-Chen Wu
- Department of Orthopaedics, Shuang Ho Hospital, Taipei Medical University, New Taipei City, 23561, Taiwan
- Department of Orthopaedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei, 110, Taiwan
- Graduate Institute of Biomedical Materials and Tissue Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei, 110, Taiwan
| | - Yueh-Ying Hsieh
- Department of Orthopaedics, Shuang Ho Hospital, Taipei Medical University, New Taipei City, 23561, Taiwan
- Department of Orthopaedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei, 110, Taiwan
| | - Ting-Shuo Hsu
- Department of Orthopaedics, Shuang Ho Hospital, Taipei Medical University, New Taipei City, 23561, Taiwan
| | - Po-Yi Liu
- Department of Orthopaedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei, 110, Taiwan
| | - Fon-Yih Tsuang
- Division of Neurosurgery, Department of Surgery, National Taiwan University Hospital, Taipei City, 10022, Taiwan
- Spine Tumor Center, National Taiwan University Hospital, Taipei City, 10022, Taiwan
| | - Yi-Jie Kuo
- Department of Orthopaedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei, 110, Taiwan
- Department of Orthopedic Surgery, Wan Fang Hospital, Taipei Medical University, Taipei City, 116, Taiwan
| | - Chia-Hsien Chen
- Department of Orthopaedics, Shuang Ho Hospital, Taipei Medical University, New Taipei City, 23561, Taiwan
- Department of Orthopaedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei, 110, Taiwan
- School of Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei, 110, Taiwan
| | - Tin Van Huynh
- Department of Interventional Cardiology, Thong Nhat Hospital, Ho Chi Minh City, Vietnam
- International Ph.D program in medicine, college of medicine, Taipei medical university, Taipei, Taiwan
| | - Chang-Jung Chiang
- Department of Orthopaedics, Shuang Ho Hospital, Taipei Medical University, New Taipei City, 23561, Taiwan.
- Department of Orthopaedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei, 110, Taiwan.
| |
Collapse
|
2
|
Deering J, Mahmoud D, Rier E, Lin Y, do Nascimento Pereira AC, Titotto S, Fang Q, Wohl GR, Deng F, Grandfield K, Elbestawi MA, Chen J. Osseointegration of functionally graded Ti6Al4V porous implants: Histology of the pore network. BIOMATERIALS ADVANCES 2023; 155:213697. [PMID: 37979439 DOI: 10.1016/j.bioadv.2023.213697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 10/11/2023] [Accepted: 11/05/2023] [Indexed: 11/20/2023]
Abstract
The additive manufacturing of titanium into porous geometries offers a means to generate low-stiffness endosseous implants with a greater surface area available for osseointegration. In this work, selective laser melting was used to produce gyroid-based scaffolds with a uniform pore size of 300 μm or functionally graded pore size from 600 μm to 300 μm. Initial in vitro assessment with Saos-2 cells showed favourable cell proliferation at pore sizes of 300 and 600 μm. Following implantation into rabbit tibiae, early histological observations at four weeks indicated some residual inflammation alongside neovessel infiltration into the scaffold interior and some early apposition of mineralized bone tissue. At twelve weeks, both scaffolds were filled with a mixture of adipocyte-rich marrow, micro-capillaries, and mineralized bone tissue. X-ray microcomputed tomography showed a higher bone volume fraction (BV/TV) and percentage of bone-implant contact (BIC) in the implants with 300 μm pores than in the functionally graded specimens. In functionally graded specimens, localized BV/TV measurement was observed to be higher in the innermost region containing smaller pores (estimated at 300-400 μm) than in larger pores at the implant exterior. The unit cell topology of the porous implant was also observed to guide the direction of bone ingrowth by conducting along the implant struts. These results suggest that in vivo experimentation is necessary alongside parametric optimization of functionally graded porous implants to predict short-term and long-term bone apposition.
Collapse
Affiliation(s)
- Joseph Deering
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada
| | - Dalia Mahmoud
- Department of Mechanical Engineering, McMaster University, Hamilton, ON, Canada; Production Engineering Department, Faculty of Engineering, Alexandria University, Alexandria 21544, Egypt
| | - Elyse Rier
- School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada
| | - Yujing Lin
- Guanghua School of Stomatology, Hospital of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, China
| | - Anna Cecilia do Nascimento Pereira
- Center of Engineering, Modeling and Applied Social Sciences, Federal University of ABC (UFABC), Santo André, Brazil; 4D Printing and Biomimetics' (4DB) Research Group, Federal University of ABC (UFABC), Santo André, Brazil
| | - Silvia Titotto
- Center of Engineering, Modeling and Applied Social Sciences, Federal University of ABC (UFABC), Santo André, Brazil; 4D Printing and Biomimetics' (4DB) Research Group, Federal University of ABC (UFABC), Santo André, Brazil
| | - Qiyin Fang
- Department of Engineering Physics, McMaster University, Hamilton, ON, Canada
| | - Gregory R Wohl
- Department of Mechanical Engineering, McMaster University, Hamilton, ON, Canada; School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada; Brockhouse Institute for Materials Research, McMaster University, Hamilton, ON, Canada
| | - Feilong Deng
- Guanghua School of Stomatology, Hospital of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, China
| | - Kathryn Grandfield
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada; School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada; Brockhouse Institute for Materials Research, McMaster University, Hamilton, ON, Canada.
| | - Mohamed A Elbestawi
- Department of Mechanical Engineering, McMaster University, Hamilton, ON, Canada.
| | - Jianyu Chen
- Guanghua School of Stomatology, Hospital of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, China.
| |
Collapse
|
3
|
Peng Y, Du L, Yang B, Fan D, Jia S, Zheng C. Efficacy of platelet-rich plasma and platelet-rich fibrin in arthroscopic rotator cuff repair: A systematic review and meta-analysis. PM R 2023; 15:1643-1653. [PMID: 37526570 DOI: 10.1002/pmrj.13049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Revised: 06/27/2023] [Accepted: 07/07/2023] [Indexed: 08/02/2023]
Abstract
OBJECTIVE Basic scientific studies have demonstrated positive effects of platelet-rich therapies, such as platelet-rich plasma (PRP) and platelet-rich fibrin (PRF), on tendon repair. However, clinical evidence indicating improved prognosis is controversial. In this study, we aimed to determine whether augmentation of arthroscopic rotator cuff repair with PRP and PRF improves outcomes compared to arthroscopic repair alone. LITERATURE SURVEY PubMed, Embase, and Cochrane library databases were comprehensively searched for randomized controlled trials (RCTs) published until June 2022 according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. No language restriction was applied. METHODOLOGY The primary outcomes were the rate of repeat tears after arthroscopic rotator cuff repair (retear rate) and clinical function scores (Constant-Murley Score, University of California, Los Angeles Score), and the extracted data were assessed for quality. Statistical analyses were performed using Review manager 5.3, and p < .05 was considered statistically significant. SYNTHESIS Ten RCTs with 628 patients were included. The results showed that augmenting surgery with PRP reduces retear rates compared to surgery alone (risk ratio [RR] = 0.40, 95% confidence interval [CI] 0.23-0.69, p = .001), whereas PRF has no effect on retear rates (p = .92). Regarding clinical function, PRP improves Constant-Murley scores (mean difference [MD] = 2.03, 95% CI 0.13-3.93, p = .04) and University of California, Los Angeles scores (MD = 1.30, 95% CI 0.36-2.24, p = .007), whereas PRF improves only Constant-Murley scores (MD = 3.93, 95% CI 1.50-6.36, p = .002). However, these differences were small and below the minimum clinically important difference threshold. CONCLUSIONS This study showed that compared to arthroscopic rotator cuff repair alone, the application of PRP in arthroscopic rotator cuff repair reduces retear rate and improves clinical function scores, whereas the application of PRF has no clinically meaningful benefit. The small number and heterogeneity of studies as well as methodological limitations and risk of bias limit confidence in the true effect.
Collapse
Affiliation(s)
- Yundong Peng
- School of Sports Medicine and Rehabilitation, Beijing Sport University, Beijing, China
| | - Liang Du
- Department of Rehabilitation Medicine, PLA Middle Military Command General Hospital, Wuhan, China
| | - Bowen Yang
- Division of Pediatric Healthcare, Department of Pediatrics, Children's Rehabilitation Center, Tongji Hospital of Tongji Medical College of Huazhong University of Science and Technology, Wuhan, China
| | - Donghao Fan
- Department of Rehabilitation Medicine, People's Hospital of Henan University of Chinese Medicine, Zhengzhou, China
| | - Shaohui Jia
- Hubei Key Laboratory of Sport Training and Monitoring, College of Sports Medicine, Wuhan Sports University, Wuhan, China
| | - Cheng Zheng
- Department of Sports Medicine, Affiliated Hospital, Wuhan Sports University, Wuhan, China
| |
Collapse
|
4
|
Wang L, Huang H, Yuan H, Yao Y, Park JH, Liu J, Geng X, Zhang K, Hollister SJ, Fan Y. In vitro fatigue behavior and in vivo osseointegration of the auxetic porous bone screw. Acta Biomater 2023; 170:185-201. [PMID: 37634835 DOI: 10.1016/j.actbio.2023.08.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 07/28/2023] [Accepted: 08/21/2023] [Indexed: 08/29/2023]
Abstract
The incidence of screw loosening, migration, and pullout caused by the insufficient screw-bone fixation stability is relatively high in clinical practice. To solve this issue, the auxetic unit-based porous bone screw (AS) has been put forward in our previous work. Its favorable auxetic effect can improve the primary screw-bone fixation stability after implantation. However, porous structure affected the fatigue behavior and in vivo longevity of bone screw. In this study, in vitro fatigue behaviors and in vivo osseointegration performance of the re-entrant unit-based titanium auxetic bone screw were studied. The tensile-tensile fatigue behaviors of AS and nonauxetic bone screw (NS) with the same porosity (51%) were compared via fatigue experiments, fracture analysis, and numerical simulation. The in vivo osseointegration of AS and NS were compared via animal experiment and biomechanical analysis. Additionally, the effects of in vivo dynamic tensile loading on the osseointegration of AS and NS were investigated and analyzed. The fatigue strength of AS was approximately 43% lower while its osseointegration performance was better than NS. Under in vivo dynamic tensile loading, the osseointegration of AS and NS both improved significantly, with the maximum increase of approximately 15%. Preferrable osseointegration of AS might compensate for the shortage of fatigue resistance, ensuring its long-term stability in vivo. Adequate auxetic effect and long-term stability of the AS was supposed to provide enough screw-bone fixation stability to overcome the shortages of the solid bone screw, developing the success of surgery and showing significant clinical application prospects in orthopedic surgery. STATEMENT OF SIGNIFICANCE: This research investigated the high-cycle fatigue behavior of re-entrant unit-based auxetic bone screw under tensile-tensile cyclic loading and its osseointegration performance, which has not been focused on in existing studies. The fatigue strength of auxetic bone screw was lower while the osseointegration was better than non-auxetic bone screw, especially under in vivo tensile loading. Favorable osseointegration of auxetic bone screw might compensate for the shortage of fatigue resistance, ensuring its long-term stability and longevity in vivo. This suggested that with adequate auxetic effect and long-term stability, the auxetic bone screw had significant application prospects in orthopedic surgery. Findings of this study will provide a theoretical guidance for design optimization and clinical application of the auxetic bone screw.
Collapse
Affiliation(s)
- Lizhen Wang
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100083, China
| | - Huiwen Huang
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100083, China
| | - Hao Yuan
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100083, China
| | - Yan Yao
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100083, China
| | - Jeong Hun Park
- Wallace H. Coulter Department of Biomedical Engineering and Center for 3D Medical Fabrication, Georgia Institute of Technology and Emory University, 313 Ferst Drive, Atlanta, GA 30332, USA
| | - Jinglong Liu
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100083, China
| | - Xuezheng Geng
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100083, China
| | - Kuo Zhang
- Laboratory Animal Science Center, Peking University Health Science Center, Beijing 100083, China
| | - Scott J Hollister
- Wallace H. Coulter Department of Biomedical Engineering and Center for 3D Medical Fabrication, Georgia Institute of Technology and Emory University, 313 Ferst Drive, Atlanta, GA 30332, USA
| | - Yubo Fan
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100083, China.
| |
Collapse
|
5
|
Bandyopadhyay A, Mitra I, Goodman SB, Kumar M, Bose S. Improving Biocompatibility for Next Generation of Metallic Implants. PROGRESS IN MATERIALS SCIENCE 2023; 133:101053. [PMID: 36686623 PMCID: PMC9851385 DOI: 10.1016/j.pmatsci.2022.101053] [Citation(s) in RCA: 19] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The increasing need for joint replacement surgeries, musculoskeletal repairs, and orthodontics worldwide prompts emerging technologies to evolve with healthcare's changing landscape. Metallic orthopaedic materials have a shared application history with the aerospace industry, making them only partly efficient in the biomedical domain. However, suitability of metallic materials in bone tissue replacements and regenerative therapies remains unchallenged due to their superior mechanical properties, eventhough they are not perfectly biocompatible. Therefore, exploring ways to improve biocompatibility is the most critical step toward designing the next generation of metallic biomaterials. This review discusses methods of improving biocompatibility of metals used in biomedical devices using surface modification, bulk modification, and incorporation of biologics. Our investigation spans multiple length scales, from bulk metals to the effect of microporosities, surface nanoarchitecture, and biomolecules such as DNA incorporation for enhanced biological response in metallic materials. We examine recent technologies such as 3D printing in alloy design and storing surface charge on nanoarchitecture surfaces, metal-on-metal, and ceramic-on-metal coatings to present a coherent and comprehensive understanding of the subject. Finally, we consider the advantages and challenges of metallic biomaterials and identify future directions.
Collapse
Affiliation(s)
- Amit Bandyopadhyay
- W. M. Keck Biomedical Materials Research Laboratory, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164-2920
| | - Indranath Mitra
- W. M. Keck Biomedical Materials Research Laboratory, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164-2920
| | - Stuart B. Goodman
- Department of Orthopedic Surgery, Stanford University Medical Center, Redwood City, CA 94063
| | | | - Susmita Bose
- W. M. Keck Biomedical Materials Research Laboratory, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164-2920
| |
Collapse
|
6
|
Wang Y, Ren C, Bi F, Li P, Tian K. The hydroxyapatite modified 3D printed poly L-lactic acid porous screw in reconstruction of anterior cruciate ligament of rabbit knee joint: a histological and biomechanical study. BMC Musculoskelet Disord 2023; 24:151. [PMID: 36849968 PMCID: PMC9969685 DOI: 10.1186/s12891-023-06245-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 02/15/2023] [Indexed: 03/01/2023] Open
Abstract
BACKGROUND 3D printing technology has become a research hotspot in the field of scientific research because of its personalized customization, maneuverability and the ability to achieve multiple material fabrications. The focus of this study is to use 3D printing technology to customize personalized poly L-lactic acid (PLLA) porous screws in orthopedic plants and to explore its effect on tendon-bone healing after anterior cruciate ligament (ACL) reconstruction. METHODS Preparation of PLLA porous screws with good orthogonal pore structure by 3D printer. The hydroxyapatite (HA) was adsorbed on porous screws by electrostatic layer-by-layer self-assembly (ELSA) technology, and PLLA-HA porous screws were prepared. The surface and spatial morphology of the modified screws were observed by scanning electron microscopy (SEM). The porosity of porous screw was measured by liquid displacement method. Thirty New Zealand male white rabbits were divided into two groups according to simple randomization. Autologous tendon was used for right ACL reconstruction, and porous screws were inserted into the femoral tunnel to fix the transplanted tendon. PLLA group was fixed with porous screws, PLLA-HA group was fixed with HA modified porous screws. At 6 weeks and 12 weeks after surgery, 5 animals in each group were sacrificed randomly for histological examination. The remaining 5 animals in each group underwent Micro-CT and biomechanical tests. RESULTS The pores of PLLA porous screws prepared by 3D printer were uniformly distributed and connected with each other, which meet the experimental requirements. HA was evenly distributed in the porous screw by ELSA technique. Histology showed that compared with PLLA group, mature bone trabeculae were integrated with grafted tendons in PLLA-HA group. Micro-CT showed that the bone formation index of PLLA-HA group was better than that of PLLA group. The new bone was uniformly distributed in the bone tunnel along the screw channel. Biomechanical experiments showed that the failure load and stiffness of PLLA-HA group were significantly higher than those of PLLA group. CONCLUSIONS The 3D printed PLLA porous screw modified by HA can not only fix the grafted tendons, but also increase the inductivity of bone, promote bone growth in the bone tunnel and promote bone integration at the tendon-bone interface. The PLLA-HA porous screw is likely to be used in clinic in the future.
Collapse
Affiliation(s)
- Yafei Wang
- Department of Orthopedic Surgery, the First Affiliated Hospital of Zhengzhou University, NO.1 Jianshe East Road, Zhengzhou, China
| | - Chengzhen Ren
- Department of Orthopedic Surgery, the First Affiliated Hospital of Zhengzhou University, NO.1 Jianshe East Road, Zhengzhou, China
| | - Fanggang Bi
- Department of Orthopedic Surgery, the First Affiliated Hospital of Zhengzhou University, NO.1 Jianshe East Road, Zhengzhou, China
| | - Pengju Li
- Department of Orthopedic Surgery, the Honghui Hospital of Xi'an, No. 76 Nanguo road, Nan Xiaomen, Xi'an, 710054, China
| | - Ke Tian
- Department of Orthopedic Surgery, the First Affiliated Hospital of Zhengzhou University, NO.1 Jianshe East Road, Zhengzhou, China.
| |
Collapse
|
7
|
Sharma P, Baghel A, Keshav K, Kumar A, Singh A, Singh AB. Functional Outcomes of Anterior Cruciate Ligament Reconstruction Using Titanium Adjustable Loop Button and Poly-L-co-DL-Lactic Acid-Beta Tricalcium Phosphate (PLDLA-bTCP) Interference Screws: A Single-Center, Retrospective, Observational Study. Cureus 2023; 15:e34542. [PMID: 36879706 PMCID: PMC9985307 DOI: 10.7759/cureus.34542] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/02/2023] [Indexed: 02/05/2023] Open
Abstract
Background The anterior cruciate ligament (ACL) reconstruction is a standard surgery in patients with instability of the knee caused by ACL insufficiency. Several differential procedures using grafts and implants such as loops, buttons, and screws have been described. This study aimed to assess the functional outcomes of ACL reconstruction surgery using titanium adjustable loop buttons and poly-L-co-DL-lactic acid-beta tricalcium phosphate (PLDLA-bTCP) interference screws. Methodology This was a retrospective, observational, single-center, and clinical study. A total of 42 patients who underwent ACL reconstruction at a tertiary trauma center in northern India between 2018 and 2022 were recruited. Data including demographics, details of the injury, surgery, implants, and surgical outcomes were collected from the patients' medical records. Further, post-surgery details such as re-injury, adverse events, International Knee Documentation Committee (IKDC) profiles, and Lysholm knee score were recorded from the enrolled patients through a telephonic follow-up. Pain score and Tegner activity scale were used to compare the knee status before and after surgery. Results At the time of surgery, the mean age of the recruited patients was 31.1 ± 8.8 years, with a male preponderance of 93%. About 57% of patients had left knee injuries. The common symptoms were instability (67%), pain (62%), swelling (14%), and giving away (5%). During surgery, titanium adjustable loop button and PLDLA-bTCP interference screw implants were used in all patients. The mean follow-up time was 21.2 ± 14.2 months. Based on patient responses, the mean IKDC and Lysholm scores were found to be 54.02 ± 5.93 and 94.4 ± 4.73, respectively. Further, the proportion of patients reporting pain decreased from 62% before surgery to 21% after surgery. The mean Tegner score revealed a significant increase in the activity levels of the patients post-surgery compared to pre-surgery (p < 0.05). Lastly, no adverse events or re-injuries were reported in any of the patients during follow-up. Conclusions Our findings revealed a significant improvement in Tegner activity levels and pain scores after surgery. In addition, patient-reported IKDC and Lysholm scores fell under the category of good knee status and function, suggesting a satisfactory functional outcome of ACL reconstruction. Hence, titanium adjustable loop and PLDLA-bTCP interference screws may be a good choice of implants for successful ACL reconstruction surgery.
Collapse
Affiliation(s)
- Pulak Sharma
- Orthopaedics, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, IND
| | - Anurag Baghel
- Orthopaedics, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, IND
| | - Kumar Keshav
- Orthopaedics, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, IND
| | - Amit Kumar
- Orthopaedics, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, IND
| | - Abhishek Singh
- Orthopaedics, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, IND
| | - Amarendra B Singh
- Orthopaedics, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, IND
| |
Collapse
|
8
|
Biocompatibility and Biological Performance of Additive-Manufactured Bioabsorbable Iron-Based Porous Interference Screws in a Rabbit Model: A 1-Year Observational Study. Int J Mol Sci 2022; 23:ijms232314626. [PMID: 36498952 PMCID: PMC9740248 DOI: 10.3390/ijms232314626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Revised: 11/20/2022] [Accepted: 11/20/2022] [Indexed: 11/24/2022] Open
Abstract
This study evaluated the mid-term (12-month) biomechanical, biocompatibility, and biological performance of additive-manufactured bioabsorbable iron-based interference screws (ISs). Two bioabsorbable iron IS types-manufactured using pure iron powder (iron_IS) and using pure iron powder with 0.2 wt% tricalcium phosphate (TCP_IS)-were compared with conventional metallic IS (control) using in vitro biocompatibility and degradation analyses and an in vivo animal study. The in vitro ultimate failure strength was significantly higher for iron_IS and TCP_IS than for control ISs at 3 months post-operatively; however, the difference between groups were nonsignificant thereafter. Moreover, at 3 months after implantation, iron_IS and TCP_IS increased bone volume fraction, bone surface area fraction, and percent intersection surface; the changes thereafter were nonsignificant. Iron_IS and TCP_IS demonstrated degradation over time with increased implant surface, decreased implant volume, and structure thickness; nevertheless, the analyses of visceral organs and biochemistry demonstrated normal results, except for time-dependent iron deposition in the spleen. Therefore, compared with conventional ISs, bioabsorbable iron-based ISs exhibit higher initial mechanical strength. Although iron-based ISs demonstrate high biocompatibility 12 months after implantation, their corrosive iron products may accumulate in the spleen. Because they demonstrate mechanical superiority along with considerable absorption capability after implantation, iron-based ISs may have potential applications in implantable medical-device development in the future.
Collapse
|
9
|
Cardona-Ramirez S, Cook JL, Stoker AM, Ma R. Small laboratory animal models of anterior cruciate ligament reconstruction. J Orthop Res 2022; 40:1967-1980. [PMID: 35689508 DOI: 10.1002/jor.25395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 04/19/2022] [Accepted: 06/08/2022] [Indexed: 02/04/2023]
Abstract
Anterior cruciate ligament (ACL) injuries are common knee ligament injuries. While generally successful, ACL reconstruction that uses a tendon graft to stabilize the knee is still associated with a notable percentage of failures and long-term morbidities. Preclinical research that uses small laboratory species (i.e., mice, rats, and rabbits) to model ACL reconstruction are important to evaluate factors that can impact graft incorporation or posttraumatic osteoarthritis after ACL reconstruction. Small animal ACL reconstruction models are also used for proof-of-concept studies for the development of emerging biological strategies aimed at improving ACL reconstruction healing. The objective of this review is to provide an overview on the use of common small animal laboratory species to model ACL reconstruction. The review includes a discussion on comparative knee anatomy, technical considerations including types of tendon grafts employed amongst the small laboratory species (i.e., mice, rats, and rabbits), and common laboratory evaluative methods used to study healing and outcomes after ACL reconstruction in small laboratory animals. The review will also highlight common research questions addressed with small animal models of ACL reconstruction.
Collapse
Affiliation(s)
- Sebastian Cardona-Ramirez
- Thompson Laboratory for Regenerative Orthopaedics, Missouri Orthopaedic Institute, University of Missouri, Columbia, Missouri, USA
| | - James L Cook
- Thompson Laboratory for Regenerative Orthopaedics, Missouri Orthopaedic Institute, University of Missouri, Columbia, Missouri, USA
| | - Aaron M Stoker
- Thompson Laboratory for Regenerative Orthopaedics, Missouri Orthopaedic Institute, University of Missouri, Columbia, Missouri, USA
| | - Richard Ma
- Thompson Laboratory for Regenerative Orthopaedics, Missouri Orthopaedic Institute, University of Missouri, Columbia, Missouri, USA
| |
Collapse
|
10
|
Guo Y, Liu F, Bian X, Lu K, Huang P, Ye X, Tang C, Li X, Wang H, Tang K. Effect of Pore Size of Porous-Structured Titanium Implants on Tendon Ingrowth. Appl Bionics Biomech 2022; 2022:2801229. [PMID: 35510044 PMCID: PMC9061050 DOI: 10.1155/2022/2801229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 03/27/2022] [Accepted: 04/05/2022] [Indexed: 11/23/2022] Open
Abstract
Purpose The reconstruction of a tendon insertion on metal prostheses is a challenge in orthopedics. Of the available metal prostheses, porous metal prostheses have been shown to have better biocompatibility for tissue integration. Therefore, this study is aimed at identifying an appropriate porous structure for the reconstruction of a tendon insertion on metal prostheses. Methods Ti6Al4V specimens with a diamond-like porous structure with triply periodic minimal surface pore sizes of 300, 500, and 700 μm and a porosity of 58% (designated Ti300, Ti500, and Ti700, respectively) were manufactured by selective laser melting and were characterized with micro-CT and scanning electron microscopy for their porosity, pore size, and surface topography. The porous specimens were implanted into the patellar tendon of rabbits. Tendon integration was evaluated after implantation into the tendon at 4, 8, and 12 weeks by histology, and the fixation strength was evaluated with a pull-out test at week 12. Results The average pore sizes of the Ti300, Ti500, and Ti700 implants were 261, 480, and 668 μm, respectively. The Ti500 and Ti700 implants demonstrated better tissue growth than the Ti300 implant at weeks 4, 8, and 12. At week 12, the histological score of the Ti500 implant was 13.67 ± 0.58, and it had an area percentage of type I collagen of 63.90% ± 3.41%; both of these results were significantly higher than those for the Ti300 and Ti700 implants. The pull-out load at week 12 was also the highest in the Ti500 group. Conclusion Ti6Al4V implants with a diamond-like porous structure with triply periodic minimal surface pore size of 500 μm are suitable for tendon integration.
Collapse
Affiliation(s)
- Yupeng Guo
- Department of Orthopedics/Sports Medicine Center, State Key Laboratory of Trauma, Burn, and Combined Injury, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing 400038, China
| | - Fei Liu
- Department of Orthopedics/Sports Medicine Center, State Key Laboratory of Trauma, Burn, and Combined Injury, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing 400038, China
| | - Xuting Bian
- Department of Orthopedics/Sports Medicine Center, State Key Laboratory of Trauma, Burn, and Combined Injury, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing 400038, China
| | - Kang Lu
- Department of Orthopedics/Sports Medicine Center, State Key Laboratory of Trauma, Burn, and Combined Injury, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing 400038, China
| | - Pan Huang
- Department of Orthopedics/Sports Medicine Center, State Key Laboratory of Trauma, Burn, and Combined Injury, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing 400038, China
| | - Xiao Ye
- Department of Orthopedics/Sports Medicine Center, State Key Laboratory of Trauma, Burn, and Combined Injury, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing 400038, China
| | - Chuyue Tang
- Department of Orthopedics/Sports Medicine Center, State Key Laboratory of Trauma, Burn, and Combined Injury, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing 400038, China
| | - Xinxin Li
- Department of Orthopedics/Sports Medicine Center, State Key Laboratory of Trauma, Burn, and Combined Injury, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing 400038, China
| | - Huan Wang
- Department of Orthopedics/Sports Medicine Center, State Key Laboratory of Trauma, Burn, and Combined Injury, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing 400038, China
| | - Kanglai Tang
- Department of Orthopedics/Sports Medicine Center, State Key Laboratory of Trauma, Burn, and Combined Injury, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing 400038, China
| |
Collapse
|
11
|
Peng Y, Li X, Wu W, Ma H, Wang G, Jia S, Zheng C. Effect of Mechanical Stimulation Combined With Platelet-Rich Plasma on Healing of the Rotator Cuff in a Murine Model. Am J Sports Med 2022; 50:1358-1368. [PMID: 35188809 DOI: 10.1177/03635465211073339] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Mechanical stimulation and platelet-rich plasma (PRP) have been shown to be beneficial for healing of the bone-tendon interface (BTI), but few studies have explored the efficacy of a combination of these applications. We investigated the effect of mechanical stimulation combined with PRP on rotator cuff repair in mice. HYPOTHESIS Mechanical stimulation combined with PRP can enhance BTI healing in a murine model of rotator cuff repair. STUDY DESIGN Controlled laboratory study. METHODS A total of 160 C57BL/6 mice were used. Overall, 40 mice were used to prepare PRP, while 120 mice underwent acute supraspinatus tendon (SST) repair. The animals were randomly assigned to 4 groups: control group, mechanical stimulation group, PRP group, and mechanical stimulation combined with PRP group (combination group). At 4 and 8 weeks postoperatively, animals were sacrificed, the eyeballs were removed to collect blood, and the SST-humeral complexes were collected. Histological, biomechanical, immunological, and bone morphometric tests were performed. RESULTS Histologically, at 4 and 8 weeks after surgery, the area of the fibrocartilage layer at the BTI in the combination group was larger than in the other groups. The content and distribution of proteoglycans in this layer in the combination group were significantly greater than in the other groups. At 8 weeks postoperatively, trabecular number, and trabecular bone thickness of the subchondral bone area of interest at the BTI of the combination group were greater than those of the other groups, bone volume fraction of the combination group was greater than the control group. On biomechanical testing at 4 and 8 weeks after surgery, the failure load and ultimate strength of the SST-humeral complex in the combination group were higher than in the other groups. Enzyme-linked immunosorbent assay results showed that, at 4 weeks postoperatively, the serum concentrations of transforming growth factor beta 1 and platelet-derived growth factor (PDGF) in the combination group were significantly higher than in the other groups; at 8 weeks, the PDGF-AB concentration in the combination group was higher than in the control and mechanical stimulation groups. CONCLUSION Mechanical stimulation combined with PRP can effectively promote the early stage of healing after a rotator cuff injury. CLINICAL RELEVANCE These findings imply that mechanical stimulation combined with PRP can serve as a potential therapeutic strategy for rotator cuff healing.
Collapse
Affiliation(s)
- Yundong Peng
- College of Health Science, Wuhan Sports University, Wuhan, China
| | - Xiaomei Li
- College of Health Science, Wuhan Sports University, Wuhan, China.,Medical College, Huainan Union University, Huainan, China
| | - Wenxia Wu
- College of Health Science, Wuhan Sports University, Wuhan, China.,Department of Rehabilitation Therapy, Jinci College of Shanxi Medical University, Taiyuan, China
| | - Haozhe Ma
- College of International Education, Wuhan Sports University, Wuhan, China
| | - Guanglan Wang
- College of Health Science, Wuhan Sports University, Wuhan, China
| | - Shaohui Jia
- Hubei Provincial Collaborative Innovation Center for Exercise and Health Promotion, College of Health Science, Wuhan Sports University, Wuhan, China
| | - Cheng Zheng
- Department of Sports Medicine, Affiliated Hospital, Wuhan Sports University, Wuhan, China
| |
Collapse
|
12
|
Luo Y, Zhang C, Wang J, Liu F, Chau KW, Qin L, Wang J. Clinical translation and challenges of biodegradable magnesium-based interference screws in ACL reconstruction. Bioact Mater 2021; 6:3231-3243. [PMID: 33778201 PMCID: PMC7966853 DOI: 10.1016/j.bioactmat.2021.02.032] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Revised: 02/07/2021] [Accepted: 02/23/2021] [Indexed: 12/27/2022] Open
Abstract
As one of the most promising fixators developed for anterior cruciate ligament (ACL) reconstruction, biodegradable magnesium (Mg)-based interference screws have gained increasing attention attributed to their appropriate modulus and favorable biological properties during degradation after surgical insertion. However, its fast degradation and insufficient mechanical strength have also been recognized as one of the major causes to limit their further application clinically. This review focused on the following four parts. Firstly, the advantages of Mg or its alloys over their counterparts as orthopaedic implants in the fixation of tendon grafts in ACL reconstruction were discussed. Subsequently, the underlying mechanisms behind the contributions of Mg ions to the tendon-bone healing were introduced. Thirdly, the technical challenges of Mg-based interference screws towards clinical trials were discussed, which was followed by the introduction of currently used modification methods for gaining improved corrosion resistance and mechanical properties. Finally, novel strategies including development of Mg/Titanium (Ti) hybrid fixators and Mg-based screws with innovative structure for achieving clinically customized therapies were proposed. Collectively, the advancements in the basic and translational research on the Mg-based interference screws may lay the foundation for exploring a new era in the treatment of the tendon-bone insertion (TBI) and related disorders.
Collapse
Affiliation(s)
- Ying Luo
- School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, 510006, China
| | - Chao Zhang
- School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, 510006, China
| | - Jue Wang
- Hanglok-Tech Co., Ltd., Hengqin New Area, China
| | - Fangfei Liu
- State Key Laboratory for Advanced Metals and Materials, University of Science and Technology Beijing, Beijing, 100083, China
| | - Kelvin Wingho Chau
- Musculoskeletal Research Laboratory, Department of Orthopaedics & Traumatology, The Chinese University of Hong Kong, Hong Kong, China
| | - Ling Qin
- Musculoskeletal Research Laboratory, Department of Orthopaedics & Traumatology, The Chinese University of Hong Kong, Hong Kong, China
| | - Jiali Wang
- School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, 510006, China
| |
Collapse
|
13
|
Biocompatibility and Biological Performance Evaluation of Additive-Manufactured Bioabsorbable Iron-Based Porous Suture Anchor in a Rabbit Model. Int J Mol Sci 2021; 22:ijms22147368. [PMID: 34298988 PMCID: PMC8307211 DOI: 10.3390/ijms22147368] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 06/23/2021] [Accepted: 07/05/2021] [Indexed: 12/17/2022] Open
Abstract
This study evaluated the biocompatibility and biological performance of novel additive-manufactured bioabsorbable iron-based porous suture anchors (iron_SAs). Two types of bioabsorbable iron_SAs, with double- and triple-helical structures (iron_SA_2_helix and iron_SA_3_helix, respectively), were compared with the synthetic polymer-based bioabsorbable suture anchor (polymer_SAs). An in vitro mechanical test, MTT assay, and scanning electron microscope (SEM) analysis were performed. An in vivo animal study was also performed. The three types of suture anchors were randomly implanted in the outer cortex of the lateral femoral condyle. The ultimate in vitro pullout strength of the iron_SA_3_helix group was significantly higher than the iron_SA_2_helix and polymer_SA groups. The MTT assay findings demonstrated no significant cytotoxicity, and the SEM analysis showed cells attachment on implant surface. The ultimate failure load of the iron_SA_3_helix group was significantly higher than that of the polymer_SA group. The micro-CT analysis indicated the iron_SA_3_helix group showed a higher bone volume fraction (BV/TV) after surgery. Moreover, both iron SAs underwent degradation with time. Iron_SAs with triple-helical threads and a porous structure demonstrated better mechanical strength and high biocompatibility after short-term implantation. The combined advantages of the mechanical superiority of the iron metal and the possibility of absorption after implantation make the iron_SA a suitable candidate for further development.
Collapse
|
14
|
Yao Y, Yuan H, Huang H, Liu J, Wang L, Fan Y. Biomechanical design and analysis of auxetic pedicle screw to resist loosening. Comput Biol Med 2021; 133:104386. [PMID: 33878515 DOI: 10.1016/j.compbiomed.2021.104386] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Revised: 04/06/2021] [Accepted: 04/06/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND Pedicle screws are widely used in fusion surgery, while screw loosening often occurrs. An auxetic structures based pedicle screw was proposed to improve the bone-screw fixation by radial expansion of the screw body under tensile force to resist pulling out. It was optimized to obtain excellent anti-pullout ability for a particular bone based on the biomechanical interaction between screw and surrounding bone. METHODS The screw was designed based on re-entrant unit cells. The mechanical properties of it were adjusted by the wall thickness (t) and re-entrant angle (θ) of the unit cell, and characterized using finite element (FE) method. The designed screws were manufactured using 3D-printing, and Ti6Al4V as the materials. Subsequently, the pullout FE models were established, and verified by pulling the fabricated screws out of Sawbone blocks. The pulling out processes of screws from bone were simulated to explore the optimizing design of the screw. RESULTS The mechanical properties of the screw could be adjusted in a wide range. The biomechanical interaction between the screw and bone can affect the anti-pullout performance of the screw. With an identical elastic modulus (E), better auxiticity of the screw, resulted in a better anti-pullout performance; while an appropriate E is the necessary condition for its excellent anti-pullout performance for a particular bone. CONCLUSION Appropriate mechanical properties are necessary for the auxetic pedicle screw with excellent screw-bone fixation performance for a particular bone, which can be obtained by rationally designing the wall thickness and re-entrant angle of the unit cells.
Collapse
Affiliation(s)
- Yan Yao
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China.
| | - Hao Yuan
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China.
| | - Huiwen Huang
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China.
| | - Jinglong Liu
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China.
| | - Lizhen Wang
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China.
| | - Yubo Fan
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China; School of Engineering Medicine, Beihang University, Beijing, 100191, China.
| |
Collapse
|
15
|
Huang YM, Huang CC, Tsai PI, Yang KY, Huang SI, Shen HH, Lai HJ, Huang SW, Chen SY, Lin FH, Chen CY. Three-Dimensional Printed Porous Titanium Screw with Bioactive Surface Modification for Bone-Tendon Healing: A Rabbit Animal Model. Int J Mol Sci 2020; 21:ijms21103628. [PMID: 32455543 PMCID: PMC7279243 DOI: 10.3390/ijms21103628] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Revised: 05/17/2020] [Accepted: 05/19/2020] [Indexed: 11/16/2022] Open
Abstract
The interference screw fixation method is used to secure a graft in the tibial tunnel during anterior cruciate ligament reconstruction surgery. However, several complications have been reported, such as biodegradable screw breakage, inflammatory or foreign body reaction, tunnel enlargement, and delayed graft healing. Using additive manufacturing (AM) technology, we developed a titanium alloy (Ti6Al4V) interference screw with chemically calcium phosphate surface modification technology to improve bone integration in the tibial tunnel. After chemical and heat treatment, the titanium screw formed a dense apatite layer on the metal surface in simulated body fluid. Twenty-seven New Zealand white rabbits were randomly divided into control and additive manufactured (AMD) screw groups. The long digital extensor tendon was detached and translated into a tibial plateau tunnel (diameter: 2.0 mm) and transfixed with an interference screw while the paw was in dorsiflexion. Biomechanical analyses, histological analyses, and an imaging study were performed at 1, 3, and 6 months. The biomechanical test showed that the ultimate pull-out load failure was significantly higher in the AMD screw group in all tested periods. Micro-computed tomography analyses revealed early woven bone formation in the AMD screw group at 1 and 3 months. In conclusion, AMD screws with bioactive surface modification improved bone ingrowth and enhanced biomechanical performance in a rabbit model.
Collapse
Affiliation(s)
- Yu-Min Huang
- Department of Biomedical Engineering, National Taiwan University, Taipei 106, Taiwan; (Y.-M.H.); (S.-W.H.); (F.-H.L.)
- Department of Orthopedics, Shuang Ho Hospital, Taipei Medical University, Taipei 100, Taiwan
- Department of Orthopedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei 100, Taiwan
| | - Chih-Chieh Huang
- Department of Materials Science and Engineering, National Chiao-Tung University, Hsinchu 300, Taiwan; (C.-C.H.); (S.-Y.C.)
| | - Pei-I Tsai
- Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Hsinchu 310, Taiwan; (P.-IT.); (K.-Y.Y.); (S.-IH.); (H.-H.S.)
| | - Kuo-Yi Yang
- Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Hsinchu 310, Taiwan; (P.-IT.); (K.-Y.Y.); (S.-IH.); (H.-H.S.)
| | - Shin-I Huang
- Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Hsinchu 310, Taiwan; (P.-IT.); (K.-Y.Y.); (S.-IH.); (H.-H.S.)
| | - Hsin-Hsin Shen
- Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Hsinchu 310, Taiwan; (P.-IT.); (K.-Y.Y.); (S.-IH.); (H.-H.S.)
| | - Hong-Jen Lai
- Material and Chemical Research Laboratories, Industrial Technology Research Institute, Hsinchu 310, Taiwan;
| | - Shu-Wei Huang
- Department of Biomedical Engineering, National Taiwan University, Taipei 106, Taiwan; (Y.-M.H.); (S.-W.H.); (F.-H.L.)
| | - San-Yuan Chen
- Department of Materials Science and Engineering, National Chiao-Tung University, Hsinchu 300, Taiwan; (C.-C.H.); (S.-Y.C.)
| | - Feng-Huei Lin
- Department of Biomedical Engineering, National Taiwan University, Taipei 106, Taiwan; (Y.-M.H.); (S.-W.H.); (F.-H.L.)
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli County 360, Taiwan
| | - Chih-Yu Chen
- Department of Orthopedics, Shuang Ho Hospital, Taipei Medical University, Taipei 100, Taiwan
- Department of Orthopedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei 100, Taiwan
- Correspondence: ; Tel.: +886-970-747767
| |
Collapse
|
16
|
Su CA, Knapik DM, Trivedi NN, Megerian MF, Salata MJ, Voos JE. Femoral Interference Screw Fixation in ACL Reconstruction Using Bone-Patellar Tendon-Bone Grafts. JBJS Rev 2020; 8:e0066. [PMID: 32105240 DOI: 10.2106/jbjs.rvw.19.00066] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
» Anterior cruciate ligament (ACL) reconstruction is a commonly performed orthopaedic procedure with numerous reconstructive graft and fixation options. Interference screws have become one of the most commonly utilized methods of securing ACL grafts such as bone-patellar tendon-bone (BPTB) autografts.
» The composition of interference screws has undergone substantial evolution over the past several decades, and numerous advantages and disadvantages are associated with each design.
» The composition, geometry, and insertional torque of interference screws have important implications for screw biomechanics and may ultimately influence the strength, stability of graft fixation, and biologic healing in ACL reconstruction.
» This article reviews the development and biomechanical properties of interference screws while examining outcomes, complications, and gaps in knowledge that are associated with the use of femoral interference screws during BPTB ACL reconstruction.
Collapse
Affiliation(s)
- Charles A Su
- Department of Orthopaedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, Ohio
| | - Derrick M Knapik
- Department of Orthopaedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, Ohio
| | - Nikunj N Trivedi
- Department of Orthopaedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, Ohio
| | | | - Michael J Salata
- Department of Orthopaedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, Ohio
| | - James E Voos
- Department of Orthopaedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, Ohio
| |
Collapse
|
17
|
3D laser-printed porous Ti6Al4V dental implants for compromised bone support. J Formos Med Assoc 2020; 119:420-429. [DOI: 10.1016/j.jfma.2019.07.023] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2019] [Revised: 06/22/2019] [Accepted: 07/24/2019] [Indexed: 11/19/2022] Open
|
18
|
Han Q, Wang C, Chen H, Zhao X, Wang J. Porous Tantalum and Titanium in Orthopedics: A Review. ACS Biomater Sci Eng 2019; 5:5798-5824. [PMID: 33405672 DOI: 10.1021/acsbiomaterials.9b00493] [Citation(s) in RCA: 57] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Porous metal is metal with special porous structures, which can offer high biocompatibility and low Young's modulus to satisfy the need for orthopedic applications. Titanium and tantalum are the most widely used porous metals in orthopedics due to their excellent biomechanical properties and biocompatibility. Porous titanium and tantalum have been studied and applied for a long history until now. Here in this review, various manufacturing methods of titanium and tantalum porous metals are introduced. Application of these porous metals in different parts of the body are summarized, and strengths and weaknesses of these porous metal implants in clinical practice are discussed frankly for future improvement from the viewpoint of orthopedic surgeons. Then according to the requirements from clinics, progress in research for clinical use is illustrated in four aspects. Various creative designs of microporous and functionally gradient structure, surface modification, and functional compound systems of porous metal are exhibited as reference for future research. Finally, the directions of orthopedic porous metal development were proposed from the clinical view based on the rapid progress of additive manufacturing. Controllable design of both macroscopic anatomical bionic shape and microscopic functional bionic gradient porous metal, which could meet the rigorous mechanical demand of bone reconstruction, should be developed as the focus. The modification of a porous metal surface and construction of a functional porous metal compound system, empowering stronger cell proliferation and antimicrobial and antineoplastic property to the porous metal implant, also should be taken into consideration.
Collapse
Affiliation(s)
- Qing Han
- Department of Orthopedics, Second Hospital of Jilin University, Changchun, 130000 Jilin Province, China
| | - Chenyu Wang
- Department of Orthopedics, Second Hospital of Jilin University, Changchun, 130000 Jilin Province, China
| | - Hao Chen
- Department of Orthopedics, Second Hospital of Jilin University, Changchun, 130000 Jilin Province, China
| | - Xue Zhao
- Department of Endocrine and Metabolism, The First Hospital of Jilin University, Changchun, 130000 Jilin Province, China
| | - Jincheng Wang
- Department of Orthopedics, Second Hospital of Jilin University, Changchun, 130000 Jilin Province, China
| |
Collapse
|
19
|
Chang JZC, Tsai PI, Kuo MYP, Sun JS, Chen SY, Shen HH. Augmentation of DMLS Biomimetic Dental Implants with Weight-Bearing Strut to Balance of Biologic and Mechanical Demands: From Bench to Animal. MATERIALS 2019; 12:ma12010164. [PMID: 30621012 PMCID: PMC6337105 DOI: 10.3390/ma12010164] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/08/2018] [Revised: 12/24/2018] [Accepted: 12/27/2018] [Indexed: 12/16/2022]
Abstract
A mismatch of elastic modulus values could result in undesirable bone resorption around the dental implant. The objective of this study was to optimize direct metal laser sintering (DMLS)-manufactured Ti₆Al₄V dental implants' design, minimize elastic mismatch, allow for maximal bone ingrowth, and improve long-term fixation of the implant. In this study, DMLS dental implants with different morphological characteristics were fabricated. Three-point bending, torsional, and stability tests were performed to compare the mechanical properties of different designs. Improvement of the weaker design was attempted by augmentation with a longitudinal 3D-printed strut. The osseointegrative properties were evaluated. The results showed that the increase in porosity decreased the mechanical properties, while augmentation with a longitudinal weight-bearing strut can improve mechanical strength. Maximal alkaline phosphatase gene expression of MG63 cells attained on 60% porosity Ti₆Al₄V discs. In vivo experiments showed good incorporation of bone into the porous scaffolds of the DMLS dental implant, resulting in a higher pull-out strength. In summary, we introduced a new design concept by augmenting the implant with a longitudinal weight-bearing strut to achieve the ideal combination of high strength and low elastic modulus; our results showed that there is a chance to reach the balance of both biologic and mechanical demands.
Collapse
Affiliation(s)
| | - Pei-I Tsai
- Department of Materials Science and Engineering, National Chiao-Tung University, Hsinchu 30010, Taiwan.
- Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Hsinchu 31040, Taiwan.
| | - Mark Yen-Ping Kuo
- School of Dentistry, College of Medicine, National Taiwan University, Taipei 10051, Taiwan.
| | - Jui-Sheng Sun
- Department of Orthopedic Surgery, College of Medicine, National Taiwan University, Taipei 10002, Taiwan.
| | - San-Yuan Chen
- Department of Materials Science and Engineering, National Chiao-Tung University, Hsinchu 30010, Taiwan.
| | - Hsin-Hsin Shen
- Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Hsinchu 31040, Taiwan.
| |
Collapse
|