Hatakeyama T, Nakashima D, Mikami K, Oya A, Fujie A, Sujino A, Nakamura M, Nagura T. Evaluation of bone integrity around the acetabular cup using noninvasive laser resonance frequency analysis. J Orthop Res 2024; 42:2552-2561. [PMID: 38953239 DOI: 10.1002/jor.25925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2024] [Revised: 05/13/2024] [Accepted: 06/07/2024] [Indexed: 07/03/2024]
Abstract
Resonance frequency analysis (RFA) is valuable for assessing implant status. In a previous investigation, acetabular cup fixation was assessed using laser RFA and the pull-down force was predicted in an in vitro setting. While the pull-down force alone is sufficient for initial fixation evaluation, it is desirable to evaluate the bone strength of the foundation for subsequent fixation. Diminished bone quality causes micromotion, migration, and protracted osseointegration, consequently elevating susceptibility to periprosthetic fractures and failure of ingrained trabecular bone. Limited research exists on the evaluation of bone mineral density (BMD) around the cup using RFA. For in vivo application of laser RFA, we implemented the sweep pulse excitation method and engineered an innovative laser RFA device having low laser energy and small dimensions. We focused on a specific frequency range (2500-4500 Hz), where the peak frequency was presumed to be influenced by foundational density. Quantitative computed tomography with a phantom was employed to assess periprosthetic BMD. Correlation between the resonance frequency within the designated range and the density around the cup was evaluated both in the laboratory and in vivo using the novel laser RFA device. The Kruskal-Wallis test showed robust correlations in both experiments (laboratory study: R = 0.728, p < 0.001; in vivo study: R = 0.619, p < 0.001). Our laser RFA system can assess the quality of bone surrounding the cup. Laser RFA holds promise in predicting the risk of loosening and might aid in the decision-making process for additional fixation through screw insertion.
Collapse
Affiliation(s)
- Takuto Hatakeyama
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Japan
| | - Daisuke Nakashima
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Japan
- Department of Clinical Biomechanics, Keio University School of Medicine, Shinjuku, Japan
| | - Katsuhiro Mikami
- Faculty of Biology-Oriented Science and Technology, Kindai University, Wakayama, Japan
| | - Akihito Oya
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Japan
| | - Atsuhiro Fujie
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Japan
| | - Asahi Sujino
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Japan
| | - Masaya Nakamura
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Japan
| | - Takeo Nagura
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku, Japan
- Department of Clinical Biomechanics, Keio University School of Medicine, Shinjuku, Japan
| |
Collapse
|
2
|
Furube T, Nakashima D, Matsuda S, Mikami K, Hatakeyama T, Takeuchi M, Fukuda K, Ueno A, Okita H, Kawakubo H, Nakamura M, Nagura T, Kitagawa Y. Evaluating stiffness of gastric wall using laser resonance frequency analysis for gastric cancer. Cancer Sci 2024. [PMID: 39468628 DOI: 10.1111/cas.16383] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2024] [Revised: 10/04/2024] [Accepted: 10/15/2024] [Indexed: 10/30/2024] Open
Abstract
Tumor stiffness is drawing attention as a novel axis that is orthogonal to existing parameters such as pathological examination. We developed a new diagnostic method that focuses on differences in stiffness between tumor and normal tissue. This study comprised a clinical application of laser resonance frequency analysis (L-RFA) for diagnosing gastric cancer. L-RFA allows for precise and contactless evaluation of tissue stiffness. We used a laser to create vibrations on a sample's surface that were then measured using a vibrometer. The data were averaged and analyzed to enhance accuracy. In the agarose phantom experiments, a clear linear correlation was observed between the Young's modulus of the phantoms (0.34-0.71 MPa) and the summation of normalized vibration peaks (Score) in the 1950-4050 Hz range (R2 = 0.93145). Higher Young's moduli also resulted in lower vibration peaks at the excitation frequency, signal-to-noise (S/N) ratios, and harmonic peaks. We also conducted L-RFA measurements on gastric cancer specimens from two patients who underwent robot-assisted distal gastrectomy. Our results revealed significant waveform differences between tumor and normal regions, similar to the findings in agarose phantoms, with tumor regions exhibiting lower vibration peaks at the excitation frequency, S/N ratios, and harmonic peaks. Statistical analysis confirmed significant differences in the score between normal and tumor regions (p = 0.00354). L-RFA was able to assess tumor stiffness and holds great promise as a noninvasive diagnostic tool for gastric cancer.
Collapse
Affiliation(s)
- Tasuku Furube
- Department of Surgery, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan
| | - Daisuke Nakashima
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan
- Department of Clinical Biomechanics, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan
| | - Satoru Matsuda
- Department of Surgery, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan
| | - Katsuhiro Mikami
- Faculty of Biology-Oriented Science and Technology, Kindai University, Kinokawa, Wakayama, Japan
| | - Takuto Hatakeyama
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan
| | - Masashi Takeuchi
- Department of Surgery, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan
| | - Kazumasa Fukuda
- Department of Surgery, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan
| | - Akihisa Ueno
- Division of Diagnostic Pathology, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan
| | - Hajime Okita
- Division of Diagnostic Pathology, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan
| | - Hirofumi Kawakubo
- Department of Surgery, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan
| | - Masaya Nakamura
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan
| | - Takeo Nagura
- Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan
- Department of Clinical Biomechanics, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan
| | - Yuko Kitagawa
- Department of Surgery, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan
| |
Collapse
|
3
|
Fonseca Ulloa CA, Seeger A, Hagedorn FS, Harz T, Fölsch C, Ishaque BA, Rickert M, Jahnke A. Development and validation of an algorithm to determine the minimal factors needed for non-invasive measurement of the in vivo primary stability of cementless hip implants. Med Eng Phys 2023; 111:103932. [PMID: 36792236 DOI: 10.1016/j.medengphy.2022.103932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 11/17/2022] [Accepted: 11/23/2022] [Indexed: 12/05/2022]
Abstract
Aseptic loosening is a frequent cause for revision of endoprosthesis. X-ray examinations like Radio-Stereometry-Analysis (RSA) are among the most widely used in vivo methods for its detection. Nevertheless, this method is not used routinely because of bone marker and related radiation exposure. This work aims at creating a new in vivo concept to detect implant stability measuring micromotions without x-ray and to develop a corresponding algorithm. Based on the assumption of contactless measurement, the input parameters for the algorithm are the distances of each ultrasound sensor to the object (prosthesis and bone) and its position. First, the number of parameters necessary for a precise reconstruction and measurement of micromotions between objects had to be defined. Therefore, the algorithm has been tested with simulations of these parameters. Two experimental measurements, either using contact sensors or ultrasound, were used to prove the accuracy of the algorithm. Simulations indicate a high accuracy with three distances as initial parameters for each object. Contact measurements show precise representation of micromotion, and the contactless measurements show the possibility of detecting various materials with a high resolution. This work lays the foundations for non-invasive detection of micromotions between the implant-bone interface.
Collapse
Affiliation(s)
- Carlos A Fonseca Ulloa
- Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstrasse. 29, 35392 Giessen, Germany.
| | - Anja Seeger
- Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstrasse. 29, 35392 Giessen, Germany
| | - Frederike S Hagedorn
- Department of Pathology, University Hospital Giessen and Marburg (UKGM), Langhansstrasse, 10, 35392 Giessen, Germany
| | - Torben Harz
- Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstrasse. 29, 35392 Giessen, Germany
| | - Christian Fölsch
- Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstrasse. 29, 35392 Giessen, Germany; Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstrasse 33, 35392 Giessen, Germany
| | - Bernd A Ishaque
- Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstrasse. 29, 35392 Giessen, Germany; Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstrasse 33, 35392 Giessen, Germany
| | - Markus Rickert
- Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstrasse. 29, 35392 Giessen, Germany; Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstrasse 33, 35392 Giessen, Germany
| | - Alexander Jahnke
- Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstrasse. 29, 35392 Giessen, Germany
| |
Collapse
|
4
|
Einafshar M, Hashemi A, Kiapour A. Evaluation of the efficacy of modal analysis in predicting the pullout strength of fixation bone screws. JOR Spine 2022; 5:e1220. [PMID: 36601373 PMCID: PMC9799086 DOI: 10.1002/jsp2.1220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 06/10/2022] [Accepted: 06/16/2022] [Indexed: 11/06/2022] Open
Abstract
Background Pilot hole preparation has been shown to have an impact on the short and long-term stability of the screw fixation constructs. Purpose Investigation and comparison of two nondestructive modal analysis methods with conventional insertion torque (IT) and pullout tests in optimum pilot hole diameter detection. Methods Twenty conical core titanium screws were embedded in high-density polyethylene blocks with different pilot hole diameters. The maximum IT was recorded for each screw during implantation. Then, two modal analysis methods including accelerometer (classical modal analysis [CMA]) and acoustic modal analysis (AMA) were carried out to measure the natural frequency (NF) of the bone-screw structure. Finally, stiffness (S), pullout force (Fult), displacement at Fult (dult) and energy dissipation (ED) were obtained from the destructive pullout test. Results The IT increased, as the pilot hole diameter decreased. The maximum value of IT was observed in the smallest pilot hole diameter. The same trend was found for the Fult and the first NF derived from both modal methods except for 5.5 mm pilot hole diameter. The natural NFs derived from CMA and AMA showed high correlations in different groups (R2 = 0.94) and did not deviate from y = x hypothesis in linear regression analysis. The Fult, dult, and ED were measured 4800 ± 172 N, 3.10 ± 0.08 mm and 14.23 ± 1.10 N.mm, respectively. Discussion No significant change was observed in "S" between the groups. The highest Fult and first NF were obtained for the 5.5 mm pilot hole diameter. Both CMA and AMA were found to be reliable methods and can promote the undesirable contradiction between Fult and IT.
Collapse
Affiliation(s)
- Mohammadjavad Einafshar
- Biomechanical Engineering Group, Department of Biomedical EngineeringAmirkabir University of TechnologyTehranIran
- Department of Material and ProductionAalborg UniversityAalborgDenamrk
| | - Ata Hashemi
- Biomechanical Engineering Group, Department of Biomedical EngineeringAmirkabir University of TechnologyTehranIran
| | - Ali Kiapour
- Departments of NeurosurgeryMassachusetts General Hospital, Harvard Medical SchoolBostonMassachusettsUSA
| |
Collapse
|
5
|
Mikami K, Sudo N, Okamoto Y, Nagura T, Nakashima D. Sweep Pulse Excitation Method for Enhancing Photoacoustic Elastic Waves at Different Laser Irradiation Parameters. SENSORS (BASEL, SWITZERLAND) 2022; 22:5025. [PMID: 35808520 PMCID: PMC9269738 DOI: 10.3390/s22135025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Revised: 06/29/2022] [Accepted: 07/01/2022] [Indexed: 06/15/2023]
Abstract
Laser remote sensing using a sweep pulse excitation method, in which a laser beam is irradiated at the same repetition frequency as the natural frequency, for enhancing photoacoustic elastic waves through resonance effect has been studied. The sweep pulse excitation method, which is based on the principle of detecting natural frequency fluctuations, such as hammering tests, can detect natural frequencies in the audible sound region with low average laser power and contribute to the convenience and low cost of an installation strength diagnosis of fastening bolts. In this study, we investigated the dynamics of the swept excitation method for optimization by evaluating the dependence of the laser irradiation conditions (pulse width, spot size, and average power) on different metal disc samples. We discovered that the magnitude of the photoacoustic elastic wave is proportional to the absorption of laser power, and the spatiotemporal dynamics can be explained through thermal diffusion phenomena. These findings contribute to the development of laser-sensing technology based on photoacoustic elastic waves.
Collapse
Affiliation(s)
- Katsuhiro Mikami
- Faculty of Biology-Oriented Science and Technology, Kindai University, Wakayama 649-6493, Japan; (N.S.); (Y.O.)
| | - Natsumi Sudo
- Faculty of Biology-Oriented Science and Technology, Kindai University, Wakayama 649-6493, Japan; (N.S.); (Y.O.)
| | - Yuka Okamoto
- Faculty of Biology-Oriented Science and Technology, Kindai University, Wakayama 649-6493, Japan; (N.S.); (Y.O.)
| | - Takeo Nagura
- Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo 160-8582, Japan; (T.N.); (D.N.)
- Department of Clinical Biomechanics, Keio University School of Medicine, Tokyo 160-8582, Japan
| | - Daisuke Nakashima
- Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo 160-8582, Japan; (T.N.); (D.N.)
| |
Collapse
|
6
|
Mikami K, Nemoto M, Nagura T, Nakamura M, Matsumoto M, Nakashima D. Machine Learning-Based Diagnosis in Laser Resonance Frequency Analysis for Implant Stability of Orthopedic Pedicle Screws. SENSORS 2021; 21:s21227553. [PMID: 34833628 PMCID: PMC8623959 DOI: 10.3390/s21227553] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/05/2021] [Revised: 11/08/2021] [Accepted: 11/10/2021] [Indexed: 11/16/2022]
Abstract
Evaluation of the initial stability of implants is essential to reduce the number of implant failures of pedicle screws after orthopedic surgeries. Laser resonance frequency analysis (L-RFA) has been recently proposed as a viable diagnostic scheme in this regard. In a previous study, L-RFA was used to demonstrate the diagnosis of implant stability of monoaxial screws with a fixed head. However, polyaxial screws with movable heads are also frequently used in practice. In this paper, we clarify the characteristics of the laser-induced vibrational spectra of polyaxial screws which are required for making L-RFA diagnoses of implant stability. In addition, a novel analysis scheme of a vibrational spectrum using L-RFA based on machine learning is demonstrated and proposed. The proposed machine learning-based diagnosis method demonstrates a highly accurate prediction of implant stability (peak torque) for polyaxial pedicle screws. This achievement will contribute an important analytical method for implant stability diagnosis using L-RFA for implants with moving parts and shapes used in various clinical situations.
Collapse
Affiliation(s)
- Katsuhiro Mikami
- Faculty of Biology-Oriented Science and Technology, Kindai University, Wakayama 649-6493, Japan;
- Correspondence:
| | - Mitsutaka Nemoto
- Faculty of Biology-Oriented Science and Technology, Kindai University, Wakayama 649-6493, Japan;
| | - Takeo Nagura
- Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo 160-8582, Japan; (T.N.); (M.N.); (M.M.); (D.N.)
- Department of Clinical Biomechanics, Keio University School of Medicine, Tokyo 160-8582, Japan
| | - Masaya Nakamura
- Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo 160-8582, Japan; (T.N.); (M.N.); (M.M.); (D.N.)
| | - Morio Matsumoto
- Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo 160-8582, Japan; (T.N.); (M.N.); (M.M.); (D.N.)
| | - Daisuke Nakashima
- Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo 160-8582, Japan; (T.N.); (M.N.); (M.M.); (D.N.)
| |
Collapse
|
7
|
Raz P, Meir H, Levartovsky S, Peleg M, Sebaoun A, Beitlitum I. Reliability and Correlation of Different Devices for the Evaluation of Primary Implant Stability: An In Vitro Study. MATERIALS 2021; 14:ma14195537. [PMID: 34639933 PMCID: PMC8509803 DOI: 10.3390/ma14195537] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 09/13/2021] [Accepted: 09/14/2021] [Indexed: 12/14/2022]
Abstract
Our aim was to analyze the correlation between the IT evaluated by a surgical motor and the primary implant stability (ISQ) measured by two RFA devices, Osstell and Penguin, in an in vitro model. This study examines the effect of bone type (soft or dense), implant length (13 mm or 8 mm), and implant design (CC: conical connection; IH: internal hexagon), on this correlation. Ninety-six implants were inserted using a surgical motor (IT) into two types of synthetic foam blocks. Initial measurements for both the peak IT and ISQ were recorded at the point when implant insertion was stopped by the surgical motor, and the final measurements were recorded when the implant was completely inserted into the synthetic blocks using only the RFA devices. Our null hypothesis was that there is a good correlation between the devices, independent of the implant length, design, or bone type. We found a positive, significant correlation between the IT, and the Osstell and Penguin devices. Implant length and bone type did not affect this correlation. The correlation between the devices in the CC design was maintained; however, in the IH design it was maintained only between the RFA devices. We concluded that there is a high positive correlation between the IT and ISQ from a mechanical perspective, which was not affected by bone type or implant length but was affected by the implant design.
Collapse
Affiliation(s)
- Perry Raz
- Department of Periodontology and Dental Implants, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (H.M.); (A.S.); (I.B.)
- Correspondence:
| | - Haya Meir
- Department of Periodontology and Dental Implants, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (H.M.); (A.S.); (I.B.)
| | - Shifra Levartovsky
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel;
| | - Maia Peleg
- The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel;
| | - Alon Sebaoun
- Department of Periodontology and Dental Implants, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (H.M.); (A.S.); (I.B.)
| | - Ilan Beitlitum
- Department of Periodontology and Dental Implants, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (H.M.); (A.S.); (I.B.)
| |
Collapse
|