1
|
Xu H, Wu L, Xue Y, Yang T, Xiong T, Wang C, He S, Sun H, Cao Z, Liu J, Wang S, Li Z, Naeem A, Yin X, Zhang J. Advances in Structure Pharmaceutics from Discovery to Evaluation and Design. Mol Pharm 2023; 20:4404-4429. [PMID: 37552597 DOI: 10.1021/acs.molpharmaceut.3c00514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/10/2023]
Abstract
Drug delivery systems (DDSs) play an important role in delivering active pharmaceutical ingredients (APIs) to targeted sites with a predesigned release pattern. The chemical and biological properties of APIs and excipients have been extensively studied for their contribution to DDS quality and effectiveness; however, the structural characteristics of DDSs have not been adequately explored. Structure pharmaceutics involves the study of the structure of DDSs, especially the three-dimensional (3D) structures, and its interaction with the physiological and pathological structure of organisms, possibly influencing their release kinetics and targeting abilities. A systematic overview of the structures of a variety of dosage forms, such as tablets, granules, pellets, microspheres, powders, and nanoparticles, is presented. Moreover, the influence of structures on the release and targeting capability of DDSs has also been discussed, especially the in vitro and in vivo release correlation and the structure-based organ- and tumor-targeting capabilities of particles with different structures. Additionally, an in-depth discussion is provided regarding the application of structural strategies in the DDSs design and evaluation. Furthermore, some of the most frequently used characterization techniques in structure pharmaceutics are briefly described along with their potential future applications.
Collapse
Affiliation(s)
- Huipeng Xu
- Center for Drug Delivery Systems, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Li Wu
- Center for Drug Delivery Systems, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China
- Key Laboratory of Molecular Pharmacology and Drug Evaluation, School of Pharmacy, Ministry of Education, Yantai University, Yantai 264005, China
- Key Laboratory of Modern Preparation of Traditional Chinese Medicine, Ministry of Education, Jiangxi University of Chinese Medicine, Nanchang 330004, China
| | - Yanling Xue
- Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201204, China
| | - Ting Yang
- Center for Drug Delivery Systems, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China
| | - Ting Xiong
- Center for Drug Delivery Systems, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China
| | - Caifen Wang
- Center for Drug Delivery Systems, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China
| | - Siyu He
- Center for Drug Delivery Systems, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Hongyu Sun
- Center for Drug Delivery Systems, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China
| | - Zeying Cao
- Center for Drug Delivery Systems, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jun Liu
- Center for Drug Delivery Systems, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China
| | - Siwen Wang
- Center for Drug Delivery Systems, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Zhe Li
- Key Laboratory of Modern Preparation of Traditional Chinese Medicine, Ministry of Education, Jiangxi University of Chinese Medicine, Nanchang 330004, China
| | - Abid Naeem
- Key Laboratory of Modern Preparation of Traditional Chinese Medicine, Ministry of Education, Jiangxi University of Chinese Medicine, Nanchang 330004, China
| | - Xianzhen Yin
- Center for Drug Delivery Systems, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China
- Lingang Laboratory, Shanghai 201602, China
| | - Jiwen Zhang
- Center for Drug Delivery Systems, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China
- University of Chinese Academy of Sciences, Beijing 100049, China
- Key Laboratory of Modern Preparation of Traditional Chinese Medicine, Ministry of Education, Jiangxi University of Chinese Medicine, Nanchang 330004, China
- NMPA Key Laboratory for Quality Research and Evaluation of Pharmaceutical Excipients, National Institutes for Food and Drug Control, No.2 Tiantan Xili, Beijing 100050, China
| |
Collapse
|
2
|
Wolfgang M, Kern A, Deng S, Stranzinger S, Liu M, Drexler W, Leitgeb R, Haindl R. Ultra-high-resolution optical coherence tomography for the investigation of thin multilayered pharmaceutical coatings. Int J Pharm 2023; 643:123096. [PMID: 37268027 DOI: 10.1016/j.ijpharm.2023.123096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 05/25/2023] [Accepted: 05/26/2023] [Indexed: 06/04/2023]
Abstract
Optical Coherence Tomography (OCT) has recently gained attention as a promising technology for in-line monitoring of pharmaceutical film-coating processes for (single-layered) tablet coatings and end-point detection with commercial systems. An increasing interest in the investigation of multiparticulate dosage forms with mostly multi-layered coatings below 20 µm final film thickness demands advancement in OCT technology for pharmaceutical imaging. We present an ultra-high-resolution (UHR-) OCT and investigate its performance based on three different multiparticulate dosage forms with different layer structures (one single-layered, two multi-layered) with layer thicknesses in a range from 5 to 50 µm. The achieved system resolution of 2.4 µm (axial) and 3.4 µm (lateral, both in air) enables the assessment of defects, film thickness variability and morphological features within the coating, previously unattainable using OCT. Despite the high transverse resolution, the provided depth of field was found sufficient to reach the core region of all dosage forms under test. We further demonstrate an automated segmentation and evaluation of UHR-OCT images for coating thicknesses, where human experts struggle using today's standard OCT systems.
Collapse
Affiliation(s)
| | - Alice Kern
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Shiyu Deng
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | | | - Mengyang Liu
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
| | - Wolfgang Drexler
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Rainer Leitgeb
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; Christian Doppler Laboratory OPTRAMED, Medical University of Vienna, Vienna, Austria.
| | - Richard Haindl
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, 62 Nanyang Drive, Singapore, Singapore; Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
| |
Collapse
|
3
|
Vijayakumar J, Goudarzi NM, Eeckhaut G, Schrijnemakers K, Cnudde V, Boone MN. Characterization of Pharmaceutical Tablets by X-ray Tomography. Pharmaceuticals (Basel) 2023; 16:ph16050733. [PMID: 37242516 DOI: 10.3390/ph16050733] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Revised: 05/07/2023] [Accepted: 05/08/2023] [Indexed: 05/28/2023] Open
Abstract
Solid dosage forms such as tablets are extensively used in drug administration for their simplicity and large-scale manufacturing capabilities. High-resolution X-ray tomography is one of the most valuable non-destructive techniques to investigate the internal structure of the tablets for drug product development as well as for a cost effective production process. In this work, we review the recent developments in high-resolution X-ray microtomography and its application towards different tablet characterizations. The increased availability of powerful laboratory instrumentation, as well as the advent of high brilliance and coherent 3rd generation synchrotron light sources, combined with advanced data processing techniques, are driving the application of X-ray microtomography forward as an indispensable tool in the pharmaceutical industry.
Collapse
Affiliation(s)
- Jaianth Vijayakumar
- Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86/N3, 9000 Gent, Belgium
- Department of Physics and Astronomy, Radiation Physics, Ghent University, Proeftuinstraat 86/N12, 9000 Gent, Belgium
| | - Niloofar Moazami Goudarzi
- Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86/N3, 9000 Gent, Belgium
- Department of Physics and Astronomy, Radiation Physics, Ghent University, Proeftuinstraat 86/N12, 9000 Gent, Belgium
| | - Guy Eeckhaut
- Janssen Pharmaceutica, Turnhoutseweg 30, 2340 Beerse, Belgium
| | | | - Veerle Cnudde
- Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86/N3, 9000 Gent, Belgium
- Pore-Scale Processes in Geomaterials Research (PProGRess), Department of Geology, Ghent University, Krijgslaan 281/S8, 9000 Gent, Belgium
- Environmental Hydrogeology, Department of Earth Sciences, Faculty of Geosciences, Utrecht University, Princetonlaan 8A, 3584 CD Utrecht, The Netherlands
| | - Matthieu N Boone
- Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86/N3, 9000 Gent, Belgium
- Department of Physics and Astronomy, Radiation Physics, Ghent University, Proeftuinstraat 86/N12, 9000 Gent, Belgium
| |
Collapse
|
4
|
Assessment of Mini-Tablets Coating Uniformity as a Function of Fluid Bed Coater Inlet Conditions. Pharmaceutics 2021; 13:pharmaceutics13050746. [PMID: 34070006 PMCID: PMC8157842 DOI: 10.3390/pharmaceutics13050746] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 05/10/2021] [Accepted: 05/13/2021] [Indexed: 11/17/2022] Open
Abstract
This study concerned the quality of mini-tablets’ coating uniformity obtained by either the bottom spray chamber with a classical Wurster distributor (CW) or a swirl distributor (SW). Mini-tablets with a diameter of 2.0, 2.5, and 3.0 mm were coated with hypromellose using two different inlet air distributors as well as inlet airflow rates (130 and 156 m3/h). Tartrazine was used as a colorant in the coating layer and the coating uniformity was assessed by spectrophotometric analysis of solutions obtained after disintegration of the mini-tablets (n = 100). Higher uniformity of coating material distribution among the mini-tablets was observed in the case of SW distributor, even for the biggest mini-tablets (d = 3.0 mm), with an RSD no larger than 5.0%. Additionally, coating thickness was evaluated by colorimetric analysis (n = 1000), using a scanner method, and expressed as a hue value. A high correlation (R = 0.993) between inter-tablet variability of hue and UV-Vis results was obtained. Mini-tablets were successfully coated in a fluid bed system using both a classical Wurster distributor as well as a swirl generator. However, regardless of the mini-tablets’ diameter, better film uniformity was achieved in the case of a distributor with a swirl generator.
Collapse
|
5
|
Feng H, Mohan S. Application of Process Analytical Technology for Pharmaceutical Coating: Challenges, Pitfalls, and Trends. AAPS PharmSciTech 2020; 21:179. [PMID: 32596747 DOI: 10.1208/s12249-020-01727-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Accepted: 06/08/2020] [Indexed: 12/31/2022] Open
Abstract
Coating process is a critical unit operation for manufacturing solid oral dosage forms. For a long time, the coating weight gain has been discerned as the most important, if not only, characteristic describing the coating quality. As the introduction of quality by design (QbD) and advancement of process analytical technology (PAT), nowadays more techniques are available to analyze other quality attributes which have been overlooked but have substantial impacts on the performance of coated products. The techniques that permit rapid and non-destructive measurements are of particular importance to improve process operation and product quality. This article reviews the analytical techniques that have been and potentially could be used as PAT tools for characterizing the quality of pharmaceutical coating product. By identifying the challenges and pitfalls encountered during PAT application, the review aims at fostering the adoption of PAT for paving the way to enhanced quality and efficiency of the coating processes.
Collapse
Affiliation(s)
- Hanzhou Feng
- Process analytical technology, Merck & Co., Inc., Rahway, New Jersey, USA.
| | - Shikhar Mohan
- Graduate School of Pharmaceutical Sciences, Duquesne University, 600 Forbes Avenue, Pittsburgh, Pennsylvania, USA
| |
Collapse
|
6
|
At-line validation of optical coherence tomography as in-line/at-line coating thickness measurement method. Int J Pharm 2019; 572:118766. [DOI: 10.1016/j.ijpharm.2019.118766] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Revised: 10/01/2019] [Accepted: 10/03/2019] [Indexed: 11/19/2022]
|
7
|
Differentiating Generic versus Branded Pharmaceutical Tablets Using Ultra-High-Resolution Optical Coherence Tomography. COATINGS 2019. [DOI: 10.3390/coatings9050326] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Optical coherence tomography (OCT) has recently been demonstrated as a powerful tool to image through pharmaceutical film coatings. Majority of the existing systems can, however, resolve film coatings for thickness greater than 10 µm. Here we report on an ultra-high-resolution (UHR) OCT system, with 1 µm axial and 1.6 µm lateral resolutions, which can resolve thin coatings at approximately 4 µm. We further demonstrate a novel application of the system for differentiating generic and branded suppliers of paracetamol tablets.
Collapse
|
8
|
Zhang Z, Ikpatt U, Lawman S, Williams B, Zheng Y, Lin H, Shen Y. Sub-surface imaging of soiled cotton fabric using full-field optical coherence tomography. OPTICS EXPRESS 2019; 27:13951-13964. [PMID: 31163852 DOI: 10.1364/oe.27.013951] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/18/2019] [Accepted: 03/15/2019] [Indexed: 05/23/2023]
Abstract
In the laundry industry, colorimetry is a common way to evaluate the stain removal efficiency of detergents and cleaning products. For ease of visualization, the soiling agent is treated with a dye before measurement. However, it effectively measures the dye removal rather than stain removal, and it cannot provide depth-resolved information of the sample. In this study, we show that full-field (FF) optical coherence tomography (OCT) technique is capable of measuring the cleaning effect on cotton fabric by imaging the sub-surface features of fabric samples. We used a broadband light-emitting diode (LED) source to power the FF-OCT system that achieves the resolution of 1 µm axially and 1.6 µm laterally. This allows the micron-sized cotton fibres/fibrils at different depth positions to be resolved. The clean, the soiled, and the washed samples can be differentiated from their cross-sectional images using OCT, where the cleaning effect can be correlated with the sub-surface fibre volume. The experimental results of the proposed method were found to be in good agreement with those of the standard colorimetry method. The proposed technique therefore offers an alternative way for measuring the stain removal from fabric substrate to assess the effectiveness of laundry detergent products.
Collapse
|
9
|
A Review of the Applications of OCT for Analysing Pharmaceutical Film Coatings. APPLIED SCIENCES-BASEL 2018. [DOI: 10.3390/app8122700] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Optical coherence tomography (OCT) has recently attracted a lot of interest in the pharmaceutical manufacturing industry as a fast, contactless and non-destructive modality for quantifying thin film coatings on pharmaceutical dosage forms, which cannot be resolved easily with other techniques. In this topical review, we present an overview of the research that has been performed to date, highlighting key differences between systems and outlining major challenges ahead.
Collapse
|
10
|
Gardner MR, Lewis A, Park J, McElroy AB, Estrada AD, Fish S, Beaman JJ, Milner TE. In situ process monitoring in selective laser sintering using optical coherence tomography. OPTICAL ENGINEERING (REDONDO BEACH, CALIF.) 2018; 57:041407. [PMID: 29576665 PMCID: PMC5859933 DOI: 10.1117/1.oe.57.4.041407] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Selective laser sintering (SLS) is an efficient process in additive manufacturing that enables rapid part production from computer-based designs. However, SLS is limited by its notable lack of in-situ process monitoring when compared to other manufacturing processes. We report the incorporation of optical coherence tomography into an SLS system in detail and demonstrate access to surface and sub-surface features. Video frame rate cross-sectional imaging reveals areas of sintering uniformity and areas of excessive heat error with high temporal resolution. We propose a set of image processing techniques for SLS process monitoring with OCT and report the limitations and obstacles for further OCT integration with SLS systems.
Collapse
Affiliation(s)
- Michael R. Gardner
- The University of Texas at Austin, Department of Biomedical
Engineering, 107 W Dean Keeton St, Austin, TX, USA, 78712 Code
| | - Adam Lewis
- The University of Texas at Austin, McKetta Department of Chemical
Engineering, 200 E Dean Keeton St, Austin, TX, USA, 78712
| | - Jongwan Park
- The University of Texas at Austin, Department of Biomedical
Engineering, 107 W Dean Keeton St, Austin, TX, USA, 78712 Code
| | - Austin B. McElroy
- The University of Texas at Austin, Department of Biomedical
Engineering, 107 W Dean Keeton St, Austin, TX, USA, 78712 Code
| | - Arnold D. Estrada
- The University of Texas at Austin, Department of Biomedical
Engineering, 107 W Dean Keeton St, Austin, TX, USA, 78712 Code
| | - Scott Fish
- The University of Texas at Austin, Department of Mechanical
Engineering, 204 E Dean Keeton St, Austin, TX, USA, 78712
| | - Joseph J. Beaman
- The University of Texas at Austin, Department of Mechanical
Engineering, 204 E Dean Keeton St, Austin, TX, USA, 78712
| | - Thomas E. Milner
- The University of Texas at Austin, Department of Biomedical
Engineering, 107 W Dean Keeton St, Austin, TX, USA, 78712 Code
| |
Collapse
|
11
|
Markl D, Wahl P, Pichler H, Sacher S, Khinast JG. Characterization of the coating and tablet core roughness by means of 3D optical coherence tomography. Int J Pharm 2018; 536:459-466. [DOI: 10.1016/j.ijpharm.2017.12.023] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2017] [Revised: 11/30/2017] [Accepted: 12/10/2017] [Indexed: 11/25/2022]
|
12
|
Lin H, Dong Y, Markl D, Zhang Z, Shen Y, Zeitler JA. Pharmaceutical Film Coating Catalog for Spectral Domain Optical Coherence Tomography. J Pharm Sci 2017. [DOI: 10.1016/j.xphs.2017.05.032] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
13
|
Zhang J, Williams BM, Lawman S, Atkinson D, Zhang Z, Shen Y, Zheng Y. Non-destructive analysis of flake properties in automotive paints with full-field optical coherence tomography and 3D segmentation. OPTICS EXPRESS 2017; 25:18614-18628. [PMID: 29041059 DOI: 10.1364/oe.25.018614] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2017] [Accepted: 06/30/2017] [Indexed: 05/18/2023]
Abstract
Automotive coating systems are designed to protect vehicle bodies from corrosion and enhance their aesthetic value. The number, size and orientation of small metallic flakes in the base coat of the paint has a significant effect on the appearance of automotive bodies. It is important for quality assurance (QA) to be able to measure the properties of these small flakes, which are approximately 10μm in radius, yet current QA techniques are limited to measuring layer thickness. We design and develop a time-domain (TD) full-field (FF) optical coherence tomography (OCT) system to scan automotive panels volumetrically, non-destructively and without contact. We develop and integrate a segmentation method to automatically distinguish flakes and allow measurement of their properties. We test our integrated system on nine sections of five panels and demonstrate that this integrated approach can characterise small flakes in automotive coating systems in 3D, calculating the number, size and orientation accurately and consistently. This has the potential to significantly impact QA testing in the automotive industry.
Collapse
|
14
|
Šibanc R, Luštrik M, Dreu R. Analysis of pellet coating uniformity using a computer scanner. Int J Pharm 2017; 533:377-382. [PMID: 28606507 DOI: 10.1016/j.ijpharm.2017.06.016] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2017] [Revised: 05/26/2017] [Accepted: 06/05/2017] [Indexed: 11/29/2022]
Abstract
A fast method for pellet coating uniformity analysis, using a commercial computer scanner was developed. The analysis of the individual particle coating thicknesses was based on using a transparent orange colored coating layer deposited on white pellet cores. Besides the analysis of the coating thickness the information of pellet size and shape was obtained as well. Particle size dependent coating thickness and particle size independent coating variability was calculated by combining the information of coating thickness and pellet size. Decoupling coating thickness variation sources is unique to presented method. For each coating experiment around 10000 pellets were analyzed, giving results with a high statistical confidence. Proposed method was employed for the performance evaluation of classical Wurster and swirl enhanced Wurster coater operated at different gap settings and air flow rates.
Collapse
Affiliation(s)
- Rok Šibanc
- Institute of Pharmaceutics and Biopharmaceutics, Heinrich Heine University, Universitätstr. 1, 40225 Düsseldorf, Germany.
| | - Matevž Luštrik
- Faculty of Pharmacy, University of Ljubljana, Aškerčeva 7, 1000 Ljubljana, Slovenia
| | - Rok Dreu
- Faculty of Pharmacy, University of Ljubljana, Aškerčeva 7, 1000 Ljubljana, Slovenia
| |
Collapse
|
15
|
Scan-Less Line Field Optical Coherence Tomography, with Automatic Image Segmentation, as a Measurement Tool for Automotive Coatings. APPLIED SCIENCES-BASEL 2017. [DOI: 10.3390/app7040351] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
16
|
Pande P, Shelton RL, Monroy GL, Nolan RM, Boppart SA. Low-cost hand-held probe for depth-resolved low-coherence interferometry. BIOMEDICAL OPTICS EXPRESS 2017; 8:338-348. [PMID: 28101422 PMCID: PMC5231303 DOI: 10.1364/boe.8.000338] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2016] [Revised: 12/07/2016] [Accepted: 12/08/2016] [Indexed: 05/20/2023]
Abstract
We report on the development of a low-cost hand-held low-coherence interferometric imaging system based on the principle of linear optical coherence tomography (Linear OCT), a technique which was first proposed in the early 2000s as a simpler alternative to the conventional time-domain and Fourier-domain OCT. A bench-top implementation of the proposed technique is first presented and validated. The axial resolution, SNR, and sensitivity roll-of of the system was estimated to be 5.2 μm and 80 dB, and 3.7 dB over a depth of 0.15 mm, respectively. After validating the bench-top system, two hand-held probe implementations for contact-based imaging and in vivo human tympanic membrane imaging are presented. The performance of the proposed system was compared with a research-grade state-of-the-art Fourier-domain low coherence interferometry (LCI) system by imaging several biological and non-biological samples. The results of this study suggest that the proposed system might be a suitable choice for applications where imaging depth and SNR can be traded for lower cost and simpler optical design.
Collapse
Affiliation(s)
- Paritosh Pande
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois,
USA
| | - Ryan L. Shelton
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois,
USA
| | - Guillermo L. Monroy
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois,
USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois,
USA
| | - Ryan M. Nolan
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois,
USA
| | - Stephen A. Boppart
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois,
USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois,
USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois,
USA
- Department of Internal Medicine, University of Illinois at Urbana-Champaign, Urbana, Illinois,
USA
| |
Collapse
|
17
|
Faulhammer E, Kovalcik A, Wahl V, Markl D, Stelzer F, Lawrence S, Khinast J, Paudel A. Multi-methodological investigation of the variability of the microstructure of HPMC hard capsules. Int J Pharm 2016; 511:840-54. [DOI: 10.1016/j.ijpharm.2016.08.005] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2016] [Revised: 08/02/2016] [Accepted: 08/03/2016] [Indexed: 11/27/2022]
|
18
|
Lawman S, Dong Y, Williams BM, Romano V, Kaye S, Harding SP, Willoughby C, Shen YC, Zheng Y. High resolution corneal and single pulse imaging with line field spectral domain optical coherence tomography. OPTICS EXPRESS 2016; 24:12395-405. [PMID: 27410154 DOI: 10.1364/oe.24.012395] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
We report the development of a Spectral Domain Line Field Optical Coherence Tomography (LF-OCT) system, using a broad bandwidth and spatial coherent Super-Continuum (SC) source. With conventional quasi-Continuous Wave (CW) setup we achieve axial resolutions up to 2.1 μm in air and 3D volume imaging speeds up to 213 kA-Scan/s. Furthermore, we report the use of a single SC pulse, of 2 ns duration, to temporally gate an OCT B-Scan image of 70 A-Scans. This is the equivalent of 35 GA-Scans/s. We apply the CW setup for high resolution imaging of the fine structures of a human cornea sample ex-vivo. The single pulse setup is applied to imaging of a coated pharmaceutical tablet. The fixed pattern noise due to spectral noise is removed by subtracting the median magnitude A-Scan. We also demonstrate that the Fourier phase can be used to remove aberration caused artefacts.
Collapse
|
19
|
Ogien J, Dubois A. High-resolution full-field optical coherence microscopy using a broadband light-emitting diode. OPTICS EXPRESS 2016; 24:9922-31. [PMID: 27137603 DOI: 10.1364/oe.24.009922] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
High-resolution full-field optical coherence microscopy (FF-OCM) is demonstrated using a single broadband light-emitting diode (LED). The characteristics of the LED-illumination FF-OCM system are measured and compared to those obtained using a halogen lamp, the light source of reference in FF-OCM. Both light sources yield identical performance in terms of spatial resolution and detection sensitivity, using the same setup and camera. In particular, an axial resolution of 0.7 μm (in water) is reached. A Xenopus laevis tadpole and ex-vivo human skin have been imaged using both sources, resulting in similar images, showing for the first time that LEDs could favorably replace halogen lamps in high-resolution FF-OCM for biomedical imaging.
Collapse
|
20
|
Pande P, Monroy GL, Nolan RM, Shelton RL, Boppart SA. Sensor-Based Technique for Manually Scanned Hand-Held Optical Coherence Tomography Imaging. JOURNAL OF SENSORS 2016; 2016:8154809. [PMID: 29033983 PMCID: PMC5636012 DOI: 10.1155/2016/8154809] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Hand-held optical coherence tomography (OCT) imaging probes offer flexibility to image sites that are otherwise challenging to access. While the majority of hand-held imaging probes utilize galvanometer- or MEMS-scanning mirrors to transversely scan the imaging beam, these probes are commonly limited to lateral fields-of-view (FOV) of only a few millimeters. The use of a freehand manually scanned probe can significantly increase the lateral FOV. However, using the traditional fixed-rate triggering scheme for data acquisition in a manually scanned probe results in imaging artifacts due to variations in the scan velocity of the imaging probe. These artifacts result in a structurally inaccurate image of the sample. In this paper, we present a sensor-based manual scanning technique for OCT imaging, where real-time feedback from an optical motion sensor is used to trigger data acquisition. This technique is able to circumvent the problem of motion artifacts during manual scanning by adaptively altering the trigger rate based on the instantaneous scan velocity, enabling OCT imaging over a large lateral FOV. The feasibility of the proposed technique is demonstrated by imaging several biological and nonbiological samples.
Collapse
Affiliation(s)
- Paritosh Pande
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Guillermo L. Monroy
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Ryan M. Nolan
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Ryan L. Shelton
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Stephen A. Boppart
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Internal Medicine, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| |
Collapse
|
21
|
Pharmaceutical Terahertz Spectroscopy and Imaging. ADVANCES IN DELIVERY SCIENCE AND TECHNOLOGY 2016. [DOI: 10.1007/978-1-4939-4029-5_5] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
|
22
|
Zhu Y, Gao W, Zhou Y, Guo Y, Guo F, He Y. Rapid and high-resolution imaging of human liver specimens by full-field optical coherence tomography. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:116010. [PMID: 26618524 DOI: 10.1117/1.jbo.20.11.116010] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Accepted: 11/02/2015] [Indexed: 06/05/2023]
Abstract
We report rapid and high-resolution tomographic en face imaging of human liver specimens by full-field optical coherence tomography (FF-OCT). First, the arrangement of the FF-OCT system was described and the performance of the system was measured. The measured axial and lateral resolutions of the system are 0.8 and 0.9 μm, respectively. The system has a sensitivity of ∼60 dB and can achieve an imaging rate of 7 fps and a penetration depth of ∼80 μm. The histological structures of normal liver can be seen clearly in the en face tomographic images, including central veins, cords of hepatocytes separated by sinusoidal spaces, and portal area (portal vein, the hepatic arteriole, and the bile duct). A wide variety of histological subtypes of hepatocellular carcinoma was observed in en face tomographic images, revealing notable cancerous features, including the nuclear atypia (enlarged convoluted nuclei), the polygonal tumor cells with obvious resemblance to hepatocytes with enlarged nuclei. In addition, thicker fibrous bands, which make the cytoplasmic plump vesicular nuclei indistinct, were also seen in the images. Finally, comparison between the portal vein in a normal specimen versus that seen in the rare type of cholangiocarcinoma was made. The results show that the cholangiocarcinoma presents with a blurred pattern of portal vein in the lateral direction and an aggregated distribution in the axial direction; the surrounding sinusoidal spaces and nuclei of cholangiocarcinoma are absent. The findings in this work may be used as additional signs of liver cancer or cholangiocarcinoma, demonstrating capacity of FFOCT device for early cancer diagnosis and many other tumor-related studies in biopsy.
Collapse
Affiliation(s)
- Yue Zhu
- Nanjing University of Science and Technology, Department of Optical Engineering, 200 Xiao Ling Wei, Nanjing, Jiangsu 210094, China
| | - Wanrong Gao
- Nanjing University of Science and Technology, Department of Optical Engineering, 200 Xiao Ling Wei, Nanjing, Jiangsu 210094, China
| | - Yuan Zhou
- Nanjing University, Medical School of Nanjing University, 22 Hankou, Nanjing, Jiangsu 210093, China
| | - Yingcheng Guo
- Nanjing University of Science and Technology, Department of Optical Engineering, 200 Xiao Ling Wei, Nanjing, Jiangsu 210094, China
| | - Feng Guo
- Xi'an Railway Vocational & Technical Institute, Department of Mechanical and Electronic Engineering, 133 Zi Qiang Xi Lu, Xian, Shaanxi 710014, China
| | - Yong He
- Nanjing University of Science and Technology, Department of Optical Engineering, 200 Xiao Ling Wei, Nanjing, Jiangsu 210094, China
| |
Collapse
|
23
|
Agrawal AM, Pandey P. Scale Up of Pan Coating Process Using Quality by Design Principles. J Pharm Sci 2015. [DOI: 10.1002/jps.24582] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
24
|
Gao W. Fourier spectrum analysis of full-field optical coherence tomography for tissue imaging. Proc Math Phys Eng Sci 2015. [DOI: 10.1098/rspa.2015.0099] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
We propose a model of the full-field optical coherence tomography (FFOCT) technique for tissue imaging, in which the fractal model of the spatial correlation function of the refractive index of tissue is employed to approximate tissue structure. The results may be helpful for correctly interpreting en face tomographic images obtained with FFOCT.
Collapse
Affiliation(s)
- Wanrong Gao
- Department of Optical Engineering, Nanjing University of Science and Technology, 200 Xao Ling Wei, Nanjing, Jiangsu 210094, People's Republic of China
| |
Collapse
|
25
|
Lin H, Dong Y, Shen Y, Zeitler JA. Quantifying Pharmaceutical Film Coating with Optical Coherence Tomography and Terahertz Pulsed Imaging: An Evaluation. J Pharm Sci 2015; 104:3377-3385. [PMID: 26284354 PMCID: PMC4583780 DOI: 10.1002/jps.24535] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2015] [Revised: 05/12/2015] [Accepted: 05/15/2015] [Indexed: 11/08/2022]
Abstract
Spectral domain optical coherence tomography (OCT) has recently attracted a lot of interest in the pharmaceutical industry as a fast and non-destructive modality for quantification of thin film coatings that cannot easily be resolved with other techniques. Because of the relative infancy of this technique, much of the research to date has focused on developing the in-line measurement technique for assessing film coating thickness. To better assess OCT for pharmaceutical coating quantification, this paper evaluates tablets with a range of film coating thickness measured using OCT and terahertz pulsed imaging (TPI) in an off-line setting. In order to facilitate automated coating quantification for film coating thickness in the range of 30–200 μm, an algorithm that uses wavelet denoising and a tailored peak finding method is proposed to analyse each of the acquired A-scan. Results obtained from running the algorithm reveal an increasing disparity between the TPI and OCT measured intra-tablet variability when film coating thickness exceeds 100 μm. The finding further confirms that OCT is a suitable modality for characterising pharmaceutical dosage forms with thin film coatings, whereas TPI is well suited for thick coatings. © 2015 The Authors. Journal of Pharmaceutical Sciences published by Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 104:3377–3385, 2015
Collapse
Affiliation(s)
- Hungyen Lin
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, CB2 3RA, UK
| | - Yue Dong
- Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool, L69 3GJ, UK
| | - Yaochun Shen
- Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool, L69 3GJ, UK
| | - J Axel Zeitler
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, CB2 3RA, UK
| |
Collapse
|
26
|
Sondej F, Bück A, Koslowsky K, Bachmann P, Jacob M, Tsotsas E. Investigation of coating layer morphology by micro-computed X-ray tomography. POWDER TECHNOL 2015. [DOI: 10.1016/j.powtec.2014.12.050] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
27
|
Markl D, Zettl M, Hannesschläger G, Sacher S, Leitner M, Buchsbaum A, Khinast JG. Calibration-free in-line monitoring of pellet coating processes via optical coherence tomography. Chem Eng Sci 2015. [DOI: 10.1016/j.ces.2014.05.049] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
28
|
Avalle P, Pollitt M, Bradley K, Cooper B, Pearce G, Djemai A, Fitzpatrick S. Development of Process Analytical Technology (PAT) methods for controlled release pellet coating. Eur J Pharm Biopharm 2014; 87:244-51. [DOI: 10.1016/j.ejpb.2014.01.008] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2013] [Revised: 01/09/2014] [Accepted: 01/27/2014] [Indexed: 10/25/2022]
|