1
|
van Ede JM, Soic D, Pabst M. Decoding Sugars: Mass Spectrometric Advances in the Analysis of the Sugar Alphabet. MASS SPECTROMETRY REVIEWS 2025. [PMID: 39972673 DOI: 10.1002/mas.21927] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2024] [Revised: 12/18/2024] [Accepted: 01/20/2025] [Indexed: 02/21/2025]
Abstract
Monosaccharides play a central role in metabolic networks and in the biosynthesis of glycomolecules, which perform essential functions across all domains of life. Thus, identifying and quantifying these building blocks is crucial in both research and industry. Routine methods have been established to facilitate the analysis of common monosaccharides. However, despite the presence of common metabolites, most organisms utilize distinct sets of monosaccharides and derivatives. These molecules therefore display a large diversity, potentially numbering in the hundreds or thousands, with many still unknown. This complexity presents significant challenges in the study of glycomolecules, particularly in microbes, including pathogens and those with the potential to serve as novel model organisms. This review discusses mass spectrometric techniques for the isomer-sensitive analysis of monosaccharides, their derivatives, and activated forms. Although mass spectrometry allows for untargeted analysis and sensitive detection in complex matrices, the presence of stereoisomers and extensive modifications necessitates the integration of advanced chromatographic, electrophoretic, ion mobility, or ion spectroscopic methods. Furthermore, stable-isotope incorporation studies are critical in elucidating biosynthetic routes in novel organisms.
Collapse
Affiliation(s)
- Jitske M van Ede
- Department of Biotechnology, Delft University of Technology, Delft, the Netherlands
| | - Dinko Soic
- Department of Biotechnology, Delft University of Technology, Delft, the Netherlands
- Faculty of Pharmacy and Biochemistry, University of Zagreb, Zagreb, Croatia
| | - Martin Pabst
- Department of Biotechnology, Delft University of Technology, Delft, the Netherlands
| |
Collapse
|
2
|
Serafimov K, Lämmerhofer M. Comprehensive Coverage of Glycolysis and Pentose Phosphate Metabolic Pathways by Isomer-Selective Accurate Targeted Hydrophilic Interaction Liquid Chromatography-Tandem Mass Spectrometry Assay. Anal Chem 2024; 96:17271-17279. [PMID: 39425639 DOI: 10.1021/acs.analchem.4c03490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2024]
Abstract
The accurate liquid chromatography-tandem mass spectrometry analysis of phosphorylated isomers from glycolysis and pentose phosphate pathways is a challenging analytical problem in metabolomics due to extraction problems from the biological matrix, adherence to stainless steel surfaces leading to tailing in LC, and incomplete separation of hexose and pentose phosphate isomers. In this study, we present a targeted HILIC-ESI-MS/MS method based on a BEH amide fully porous 1.7 μm particle column with an inert surface coating of column hardware and multiple reaction monitoring (MRM) acquisition fully covering the glycolysis and pentose phosphate pathway metabolites. To minimize contact of the phosphorylated analytes with stainless steel surfaces, a μ-ESI-MS probe with a hybrid electrode made of PEEKsil was employed. Optimized HILIC gradient elution conditions with 100 mM ammonium formate (pH 11) provided the separation of hexose monophosphate and pentose phosphate isomers. To ensure good retention time repeatability in HILIC, perfluoroalkoxy alkane bottles were used for the mobile phase (with sd over 60 runs between 0.01 and 0.02 min). For the quantitative assay, the U-13C-labeled cell extract was spiked prior to extraction by metal oxide-based affinity chromatography (MOAC) with TiO2 beads. The concentrations of the 24 targets were quantified in HeLa and human embryonic kidney (HEK293) cells. Erastin-induced ferroptosis in HEK293 cells was accompanied by enhanced levels of fructose-1,6-bis-phosphate, 2- and 3-phosphoglycerate, and 2,3-bis-phosphoglycerate.
Collapse
Affiliation(s)
- Kristian Serafimov
- Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany
| | - Michael Lämmerhofer
- Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany
| |
Collapse
|
3
|
Chen J, Lou Y, Liu Y, Deng B, Zhu Z, Yang S, Chen D. Advances in Chromatographic and Mass Spectrometric Techniques for Analyzing Reducing Monosaccharides and Their Phosphates in Biological Samples. Crit Rev Anal Chem 2024:1-23. [PMID: 38855933 DOI: 10.1080/10408347.2024.2364232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2024]
Abstract
Reducing monosaccharides and their phosphates are critical metabolites in the central carbon metabolism pathway of living organisms. Variations in their content can indicate abnormalities in metabolic pathways and the onset of certain diseases, necessitating their analysis and detection. Reducing monosaccharides and their phosphates exhibit significant variations in content within biological samples and are present in many isomers, which makes the accurate quantification of reducing monosaccharides and their phosphates in biological samples a challenging task. Various analytical methods such as spectroscopy, fluorescence detection, colorimetry, nuclear magnetic resonance spectroscopy, sensor-based techniques, chromatography, and mass spectrometry are employed to detect monosaccharides and phosphates. In comparison, chromatography and mass spectrometry are highly favored for their ability to simultaneously analyze multiple components and their high sensitivity and selectivity. This review thoroughly evaluates the current chromatographic and mass spectrometric methods used for detecting reducing monosaccharides and their phosphates from 2013 to 2023, highlighting their efficacy and the advancements in these analytical technologies.
Collapse
Affiliation(s)
- Jiaqi Chen
- Zhengzhou Base, National Key Laboratory of Cotton Bio-breeding and Integrated Utilization, School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou, China
| | - Yifeng Lou
- Zhengzhou Base, National Key Laboratory of Cotton Bio-breeding and Integrated Utilization, School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou, China
| | - Yuwei Liu
- Zhengzhou Base, National Key Laboratory of Cotton Bio-breeding and Integrated Utilization, School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou, China
| | - Bowen Deng
- Zhengzhou Base, National Key Laboratory of Cotton Bio-breeding and Integrated Utilization, School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou, China
| | - Zheng Zhu
- Zhengzhou Base, National Key Laboratory of Cotton Bio-breeding and Integrated Utilization, School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou, China
| | - Sen Yang
- Zhengzhou Base, National Key Laboratory of Cotton Bio-breeding and Integrated Utilization, School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou, China
- Henan Key Laboratory of Nanomedicine for Targeting Diagnosis and Treatment, Zhengzhou University, Zhengzhou, China
| | - Di Chen
- Zhengzhou Base, National Key Laboratory of Cotton Bio-breeding and Integrated Utilization, School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou, China
- Henan Key Laboratory of Nanomedicine for Targeting Diagnosis and Treatment, Zhengzhou University, Zhengzhou, China
| |
Collapse
|
4
|
Laptev AY, Rozhmanova NB, Nesterenko PN. Retention behavior of carbohydrates on metal loaded chelating stationary phase under conditions of hydrophilic interaction liquid chromatography. J Chromatogr A 2024; 1714:464551. [PMID: 38065026 DOI: 10.1016/j.chroma.2023.464551] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 11/17/2023] [Accepted: 11/29/2023] [Indexed: 01/05/2024]
Abstract
The chromatographic retention of carbohydrates on chelating stationary phase loaded with different metal ions was studied under conditions of hydrophilic interaction chromatography (HILIC). The chelating stationary phases represented silica microparticles with immobilized 2-hydroxyethyliminodiacetic acid (HEIDA) groups in loose form and saturated with Ca2+, Pb2+, and La3+form. The role of loaded metal ion, the acetonitrile and methanol content in the mobile phase, buffer pH and column temperature on the retention of l-(+)-arabinose, d-(+)-maltose, l-(+)-rhamnose, d-(+)-lactose, d-(+)-xylose, glucose, fructose, sucrose, mannose, maltotriose and d-(+) raffinose was studied. The investigation was mainly focused on possible contribution of the complexation in the stationary phase on retention of carbohydrates as well as on effect of the presence metal ion in HEIDA-silica on resulting HILIC behavior of. It is shown that adsorbents with immobilized metal complexes have a good potential for the separation of organic ligands under HILIC mode.
Collapse
Affiliation(s)
- A Yu Laptev
- Department of Chemistry, Lomonosov Moscow State University, Leninskie Gory, 1/3, GSP-1, Lenin Hills, Moscow 119991, Russia
| | - N B Rozhmanova
- Department of Chemistry, Lomonosov Moscow State University, Leninskie Gory, 1/3, GSP-1, Lenin Hills, Moscow 119991, Russia
| | - P N Nesterenko
- Department of Chemistry, Lomonosov Moscow State University, Leninskie Gory, 1/3, GSP-1, Lenin Hills, Moscow 119991, Russia.
| |
Collapse
|
5
|
Gowda GAN, Pascua V, Killion CE, Paranji RK, Raftery D. Labile Metabolite Profiling in Human Blood Using Phosphorus NMR Spectroscopy. Anal Chem 2023; 95:15033-15041. [PMID: 37756488 PMCID: PMC10591760 DOI: 10.1021/acs.analchem.3c03040] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/29/2023]
Abstract
Phosphorus metabolites occupy a unique place in cellular function as critical intermediates and products of cellular metabolism. Human blood is the most widely used biospecimen in the clinic and in the metabolomics field, and hence an ability to profile phosphorus metabolites in blood, quantitatively, would benefit a wide variety of investigations of cellular functions in health and diseases. Mass spectrometry (MS) and nuclear magnetic resonance (NMR) spectroscopy are the two premier analytical platforms used in the metabolomics field. However, detection and quantitation of phosphorus metabolites by MS can be challenging due to their lability, high polarity, structural isomerism, and interaction with chromatographic columns. The conventionally used 1H NMR, on the other hand, suffers from poor resolution of these compounds. As a remedy, 31P NMR promises an important alternative to both MS and 1H NMR. However, numerous challenges including the instability of phosphorus metabolites, their chemical shift sensitivity to solvent composition, pH, salt, and temperature, and the lack of identified metabolites have so far restricted the scope of 31P NMR. In the current study, we describe a method to analyze nearly 25 phosphorus metabolites in blood using a simple one-dimensional (1D) NMR spectrum. Establishment of the identity of unknown metabolites involved a combination of (a) comprehensively analyzing an array of 1D and two-dimensional (2D) 1H/31P homonuclear and heteronuclear NMR spectra of blood; (b) mapping the central carbon metabolic pathway; (c) developing and using 1H and 31P spectral and chemical shift databases; and finally (d) confirming the putative metabolite peaks with spiking using authentic compounds. The resulting simple 1D 31P NMR-based method offers an ability to visualize and quantify the levels of intermediates and products of multiple metabolic pathways, including central carbon metabolism, in one step. Overall, the findings represent a new dimension for blood metabolite analysis and are anticipated to greatly impact the blood metabolomics field.
Collapse
Affiliation(s)
- G. A. Nagana Gowda
- Northwest Metabolomics Research Center, Anesthesiology and Pain Medicine, University of Washington, Seattle, WA 98109, United States
- Mitochondria and Metabolism Center, Anesthesiology and Pain Medicine, University of Washington, Seattle, WA 98109, United States
| | - Vadim Pascua
- Northwest Metabolomics Research Center, Anesthesiology and Pain Medicine, University of Washington, Seattle, WA 98109, United States
- Mitochondria and Metabolism Center, Anesthesiology and Pain Medicine, University of Washington, Seattle, WA 98109, United States
| | - Camerin E. Killion
- Northwest Metabolomics Research Center, Anesthesiology and Pain Medicine, University of Washington, Seattle, WA 98109, United States
- Mitochondria and Metabolism Center, Anesthesiology and Pain Medicine, University of Washington, Seattle, WA 98109, United States
| | - Rajan K. Paranji
- Department of Chemistry, University of Washington, Seattle, WA 98195, United States
| | - Daniel Raftery
- Northwest Metabolomics Research Center, Anesthesiology and Pain Medicine, University of Washington, Seattle, WA 98109, United States
- Mitochondria and Metabolism Center, Anesthesiology and Pain Medicine, University of Washington, Seattle, WA 98109, United States
- Fred Hutchinson Cancer Center, Seattle, WA 98109, United States
| |
Collapse
|
6
|
Su M, Serafimov K, Li P, Knappe C, Lämmerhofer M. Isomer selectivity of one- and two-dimensional approaches of mixed-mode and hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry for sugar phosphates of glycolysis and pentose phosphate pathways. J Chromatogr A 2023; 1688:463727. [PMID: 36566570 DOI: 10.1016/j.chroma.2022.463727] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Revised: 12/16/2022] [Accepted: 12/17/2022] [Indexed: 12/23/2022]
Abstract
In this study, the chromatographic behavior of mixed-mode and hydrophilic interaction liquid chromatography (HILIC) with the mixed-mode HILIC/strong anion-exchange (SAX) column HILICpak VT-50 2D and the two HILIC columns Atlantis Premier BEH Z-HILIC and Acquity Premier BEH Amide was assessed with regard to their separation capability of the metabolites from the glycolysis and pentose phosphate pathways. Chromatographic conditions were evaluated with the aim of achieving separation of the isomeric glycolytic phosphorylated carbohydrate metabolites free from isomeric interferences and thus allowing for selective targeted analysis by liquid chromatography with tandem mass spectrometry (MS/MS) using multiple reaction monitoring acquisition. The effects of pH values (8.0/9.0/10.0) of the ammonium bicarbonate buffer and gradient time were investigated during HILIC-MS/MS analysis, with the optimal conditions found at pH = 10.0. Separation of the pentose phosphate isomers (ribose 5- and 1-phosphate, xylulose 5-phosphate and ribulose 5-phosphate) was achieved on the mixed-mode HILIC/SAX (HILICpak VT-50 2D) column and HILIC BEH Amide column. Column performance was evaluated based on the direct comparison of chromatographic parameters, i.e. peak width at 50% and peak tailing factors of the individual metabolites. Parity plots were generated allowing a direct comparison between the normalized retention times and assessment of orthogonality of all 3 stationary phases evaluated. Separation of 7 biologically relevant hexose monophosphates metabolites turned out to be challenging by HILIC-MS/MS, with the BEH Amide providing the best individual results for such a separation. However, fructose 6-phosphate and glucose 1-phosphate co-eluted. Therefore, an on-line heart-cutting HILIC-Mixed Mode 2D-LC-QToF experiment was conducted, allowing the separation of this critical isomer pair. In this setup, the BEH Amide column in the 1D separated the majority of target metabolites, while a heart-cut of the peak from totally coeluted fructose 6-phosphate and glucose 1-phosphate was separated in the 2D with HILICpak VT50-2D column, thus allowing undisturbed determination of the glycolytic phosphorylated carbohydrate metabolites due to their chromatographic separation from hexose monophosphate metabolites. The assay specificity towards 7 common hexose monophosphates was characterized (glucose 1- and 6-phosphate, galactose 1- and 6-phosphate, fructose 6-phosphate, mannose 1- and 6-phosphate). The selectivity of some rare hexose monophosphates (allose 6-phosphate, tagatose 6-phosphate, sorbose 1-phosphate) was also tested.
Collapse
Affiliation(s)
- Min Su
- Pharmaceutical (Bio-)Analysis, Institute of Pharmaceutical Sciences, University of Tübingen, Auf der Morgenstelle 8, Tübingen 72076, Germany
| | - Kristian Serafimov
- Pharmaceutical (Bio-)Analysis, Institute of Pharmaceutical Sciences, University of Tübingen, Auf der Morgenstelle 8, Tübingen 72076, Germany
| | - Peng Li
- Pharmaceutical (Bio-)Analysis, Institute of Pharmaceutical Sciences, University of Tübingen, Auf der Morgenstelle 8, Tübingen 72076, Germany
| | - Cornelius Knappe
- Pharmaceutical (Bio-)Analysis, Institute of Pharmaceutical Sciences, University of Tübingen, Auf der Morgenstelle 8, Tübingen 72076, Germany
| | - Michael Lämmerhofer
- Pharmaceutical (Bio-)Analysis, Institute of Pharmaceutical Sciences, University of Tübingen, Auf der Morgenstelle 8, Tübingen 72076, Germany.
| |
Collapse
|
7
|
Li S, Zhang Z, Liu FL, Yuan BF, Liu TG, Feng YQ. Comprehensive Profiling of Phosphomonoester Metabolites in Saccharomyces cerevisiae by the Chemical Isotope Labeling-LC-MS Method. J Proteome Res 2023; 22:114-122. [PMID: 36484485 DOI: 10.1021/acs.jproteome.2c00507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Phosphomonoesters are important biosynthetic and energy metabolism intermediates in microorganisms. A comprehensive analysis of phosphomonoester metabolites is of great significance for the understanding of their metabolic phosphorylation process and inner mechanism. In this study, we established a pair of isotope reagent d0/d5-2-diazomethyl-N-methyl-phenyl benzamide-labeling-based LC-MS method for the comprehensive analysis of phosphomonoester metabolites. By this method, the labeled phosphomonoester metabolites specifically produced characteristic isotope paired peaks with an m/z difference of 5.0314 in the MS1 spectra and a pair of diagnostic ions (m/z 320.0693/325.1077) in the MS2 spectra. Based on this, a diagnostic ion-based strategy was established for the rapid screening, identification, and relative quantification of phosphomonoester metabolites. Using this strategy, 42 phosphomonoester metabolites were highly accurately identified fromSaccharomyces cerevisiae (S. cerevisiae). Notably, two phosphomonoesters were first detected fromS. cerevisiae. The relative quantification results indicated that the contents of nine phosphomonoester metabolites including two intermediates (Ru5P and S7P) in the pentose phosphate pathway (PPP) were significantly different between lycopene-producible and wild-type S. cerevisiae. A further enzyme assay indicated that the activity of the PPP was closely related to the production of lycopene. Our findings provide new perspectives for the related mechanism study and valuable references for making informed microbial engineering decisions.
Collapse
Affiliation(s)
- Sha Li
- Department of Chemistry, Wuhan University, Wuhan 430072, China
| | - Zheng Zhang
- Department of Chemistry, Wuhan University, Wuhan 430072, China
| | - Fei-Long Liu
- Department of Chemistry, Wuhan University, Wuhan 430072, China
| | - Bi-Feng Yuan
- School of Public Health, Wuhan University, Wuhan 430071, China
| | - Tian-Gang Liu
- Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education and School of Pharmaceutical Sciences, Wuhan University, Wuhan 430071, China
| | - Yu-Qi Feng
- Department of Chemistry, Wuhan University, Wuhan 430072, China.,School of Public Health, Wuhan University, Wuhan 430071, China
| |
Collapse
|
8
|
Targeted analysis of sugar phosphates from glycolysis pathway by phosphate methylation with liquid chromatography coupled to tandem mass spectrometry. Anal Chim Acta 2022; 1221:340099. [DOI: 10.1016/j.aca.2022.340099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 06/12/2022] [Accepted: 06/14/2022] [Indexed: 11/18/2022]
|
9
|
Li S, Liu FL, Zhang Z, Yin XM, Ye TT, Yuan BF, Feng YQ. Ultrasensitive Determination of Sugar Phosphates in Trace Samples by Stable Isotope Chemical Labeling Combined with RPLC-MS. Anal Chem 2022; 94:4866-4873. [PMID: 35274930 DOI: 10.1021/acs.analchem.2c00346] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Sugar phosphates are important metabolic intermediates in organisms and play a vital role in energy and central carbon metabolism. Profiling of sugar phosphates is of great significance but full of challenges due to their high structural similarity and low sensitivities in liquid chromatography (LC)-mass spectrometry (MS). In this study, we developed a novel stable isotope chemical labeling combined with the reversed-phase (RP)LC-MS method for ultrasensitive determination of sugar phosphates at the single-cell level. By chemical derivatization with 2-(diazo-methyl)-N-methyl-N-phenyl-benzamide (2-DMBA) and d5-2-DMBA, sugar phosphate isomers can obtain better separation and identification, and the detection sensitivities of sugar phosphates increased by 3.5-147 folds. The obtained limits of detection of sugar phosphates ranged from 5 to 16 pg/mL. Using this method, we achieved ultrasensitive and accurate quantification of 12 sugar phosphates in different trace biological samples. Benefiting from the improved separation and detection sensitivity, we successfully quantified five sugar phosphates (d-glucose 1-phosphate, d-mannose 6-phosphate, d-fructose 6-phosphate, d-glucose 6-phosphate, and seduheptulose 7-phosphate) in a single protoplast of Arabidopsis thaliana.
Collapse
Affiliation(s)
- Sha Li
- Department of Chemistry, Wuhan University, Wuhan 430072, China
| | - Fei-Long Liu
- Department of Chemistry, Wuhan University, Wuhan 430072, China
| | - Zheng Zhang
- School of Life Sciences and Hubei Key Laboratory of Genetic Regulation and Integrative Biology, Central China Normal University, Wuhan, Hubei 430079, China
| | - Xiao-Ming Yin
- Department of Chemistry, Wuhan University, Wuhan 430072, China
| | - Tian-Tian Ye
- Department of Chemistry, Wuhan University, Wuhan 430072, China
| | - Bi-Feng Yuan
- Department of Chemistry, Wuhan University, Wuhan 430072, China.,School of Public Health, Wuhan University, Wuhan 430071, China
| | - Yu-Qi Feng
- Department of Chemistry, Wuhan University, Wuhan 430072, China.,School of Public Health, Wuhan University, Wuhan 430071, China
| |
Collapse
|
10
|
Wang X, Luo X. Precursor Quantitation Methods for Next Generation Food Production. Front Bioeng Biotechnol 2022; 10:849177. [PMID: 35360389 PMCID: PMC8960114 DOI: 10.3389/fbioe.2022.849177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Accepted: 02/22/2022] [Indexed: 11/21/2022] Open
Abstract
Food is essential for human survival. Nowadays, traditional agriculture faces challenges in balancing the need of sustainable environmental development and the rising food demand caused by an increasing population. In addition, in the emerging of consumers' awareness of health related issues bring a growing trend towards novel nature-based food additives. Synthetic biology, using engineered microbial cell factories for production of various molecules, shows great advantages for generating food alternatives and additives, which not only relieve the pressure laid on tradition agriculture, but also create a new stage in healthy and sustainable food supplement. The biosynthesis of food components (protein, fats, carbohydrates or vitamins) in engineered microbial cells often involves cellular central metabolic pathways, where common precursors are processed into different proteins and products. Quantitation of the precursors provides information of the metabolic flux and intracellular metabolic state, giving guidance for precise pathway engineering. In this review, we summarized the quantitation methods for most cellular biosynthetic precursors, including energy molecules and co-factors involved in redox-reactions. It will also be useful for studies worked on pathway engineering of other microbial-derived metabolites. Finally, advantages and limitations of each method are discussed.
Collapse
Affiliation(s)
- Xinran Wang
- CAS Key Laboratory of Quantitative Engineering Biology, Shenzhen Institute of Synthetic Biology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Xiaozhou Luo
- CAS Key Laboratory of Quantitative Engineering Biology, Shenzhen Institute of Synthetic Biology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
- Shenzhen Institute of Advanced Technology, Shenzhen, China
| |
Collapse
|
11
|
Grübner M, Dunkel A, Steiner F, Hofmann T. Systematic Evaluation of Liquid Chromatography (LC) Column Combinations for Application in Two-Dimensional LC Metabolomic Studies. Anal Chem 2021; 93:12565-12573. [PMID: 34491041 DOI: 10.1021/acs.analchem.1c01857] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
In comparison to proteomics, the application of two-dimensional liquid chromatography (2D LC) in the field of metabolomics is still premature. One reason might be the elevated chemical complexity and the associated challenge of selecting proper separation conditions in each dimension. As orthogonality of dimensions is a major issue, the present study aimed for the identification of successful stationary phase combinations. To determine the degree of orthogonality, first, six different metrics, namely, Pearson's correlation coefficient (1 - |R|), the nearest-neighbor distances (H̅NND), the "asterisk equations" (AO), and surface coverage by bins (SCG), convex hulls (SCCH), and α-convex hulls (SCαH), were critically assessed by 15 artificial 2D data sets, and a systematic parameter optimization of α-convex hulls was conducted. SGG, SCαH with α = 0.1, and H̅NND generated valid results with sensitivity toward space utilization and data distribution and, therefore, were applied to pairs of experimental retention time sets obtained for >350 metabolites, selected to represent the chemical space of human urine. Normalized retention data were obtained for 23 chromatographic setups, comprising reversed-phase (RP), hydrophilic interaction liquid chromatography (HILIC), and mixed-mode separation systems with an ion exchange (IEX) contribution. As expected, no single LC setting provided separation of all considered analytes, but while conventional RP×HILIC combinations appeared rather complementary than orthogonal, the incorporation of IEX properties into the RP dimension substantially increased the 2D potential. Eventually, one of the most promising column combinations was implemented for an offline 2D LC time-of-flight mass spectrometry analysis of a lyophilized urine sample. Targeted screening resulted in a total of 164 detected metabolites and confirmed the outstanding coverage of the 2D retention space.
Collapse
Affiliation(s)
- Maria Grübner
- Chair of Food Chemistry and Molecular Sensory Science, Technical University of Munich, Lise-Meitner-Straße 34, Freising 85354, Germany.,Thermo Fisher Scientific, Dornierstraße 4, Germering 82110, Germany
| | - Andreas Dunkel
- Chair of Food Chemistry and Molecular Sensory Science, Technical University of Munich, Lise-Meitner-Straße 34, Freising 85354, Germany.,Leibniz-Institute for Food Systems Biology at the Technical University of Munich, Lise-Meitner-Straße 34, Freising 85354, Germany
| | - Frank Steiner
- Thermo Fisher Scientific, Dornierstraße 4, Germering 82110, Germany
| | - Thomas Hofmann
- Chair of Food Chemistry and Molecular Sensory Science, Technical University of Munich, Lise-Meitner-Straße 34, Freising 85354, Germany
| |
Collapse
|
12
|
Characterization and comparison of mixed-mode and reversed-phase columns; interaction abilities and applicability for peptide separation. J Chromatogr A 2021; 1648:462182. [PMID: 33979757 DOI: 10.1016/j.chroma.2021.462182] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Revised: 04/15/2021] [Accepted: 04/18/2021] [Indexed: 12/16/2022]
Abstract
In this work, two mixed-mode columns from a different manufacturers and one marketed as a reversed-phase column were characterized and compared in the terms of their interaction abilities, retentivity, peak symmetry, and applicability for peptide separation. All the tested columns contain octadecyl ligand and positively charged modifier, i.e. pyridyl group for the reversed-phase column XSelect CSH C18, quaternary alkylamine for mixed-mode column Atlantis PREMIER BEH C18 AX, and permanently charged moiety (details not available from the manufacturer) for mixed-mode column Luna Omega PS C18. For detailed characterization and comparison of their interaction potential, several approaches were used. First, a simple Walters test was performed to estimate hydrophobic and silanophilic interactions of the tested columns. The highest values of both parameters were observed for column Atlantis PREMIER BEH C18 AX. To investigate the effect of pH and buffer concentration on retention, mobile phases composed of acetonitrile and buffer (ammonium formate, pH 3.0; ammonium acetate pH 4.7 and pH 6.9) in various concentrations (5mM; 10mM; 15mM and 20mM) were used. The analysis of permanently charged compounds was used to describe the electrostatic interaction abilities of the stationary phases. The most significant contribution of electrostatic interactions to the retention was observed for Atlantis PREMIER BEH C18 AX column in the mobile phase with buffer of pH 3.0. A set of ten dipeptides, three pentapeptides and one octapeptide was used to investigate the effects of pH and buffer concentration on retention and peak symmetry. Each of the tested columns provides the optimal peak shape under different buffer pH and concentration. The gradient separation of the 14 tested peptides was used to verify the application potential of the tested columns for peptide separation. The best separation was achieved within 4 minutes on column Atlantis PREMIER BEH C18 AX.
Collapse
|
13
|
Cox N, Millard P, Charlier C, Lippens G. Improved NMR Detection of Phospho-Metabolites in a Complex Mixture. Anal Chem 2021; 93:4818-4824. [PMID: 33711235 DOI: 10.1021/acs.analchem.0c04056] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Phosphorylated metabolites are omnipresent in cells, but their analytical characterization faces several technical hurdles. Here, we detail an improved NMR workflow aimed at assigning the high-resolution subspectrum of the phospho-metabolites in a complex mixture. Combining a pure absorption J-resolved spectrum (Pell, A. J.; J. Magn. Reson. 2007, 189 (2), 293-299) with alternate on- and off-switching of the 31P coupling interaction during the t1 evolution with a pure in-phase (PIP) HSQMBC experiment (Castañar, L.; Angew. Chem., Int. Ed. 2014, 53 (32), 8379-8382) without or with total correlation spectroscopy (TOCSY) transfer during the insensitive nuclei enhancement by polarization transfer (INEPT) gives access to selective identification of the individual subspectra of the phosphorylated metabolites. Returning to the initial J-res spectra, we can extract with optimal resolution the full trace for the individual phospho-metabolites, which can then be transposed on the high-resolution quantitative one dimensional spectrum.
Collapse
Affiliation(s)
- Neil Cox
- TBI, Université de Toulouse, CNRS, INRAE, INSA, 31077 Toulouse, France
| | - Pierre Millard
- TBI, Université de Toulouse, CNRS, INRAE, INSA, 31077 Toulouse, France
| | - Cyril Charlier
- TBI, Université de Toulouse, CNRS, INRAE, INSA, 31077 Toulouse, France
| | - Guy Lippens
- TBI, Université de Toulouse, CNRS, INRAE, INSA, 31077 Toulouse, France
| |
Collapse
|
14
|
Fernández I, González-Mora JL, Lorenzo-Luis P, Villalonga R, Salazar-Carballo PA. Nickel oxide nanoparticles-modified glassy carbon electrodes for non-enzymatic determination of total sugars in commercial beverages. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105538] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
15
|
Fu X, Cebo M, Ikegami T, Lämmerhofer M. Separation of carbohydrate isomers and anomers on poly-N-(1H-tetrazole-5-yl)-methacrylamide-bonded stationary phase by hydrophilic interaction chromatography as well as determination of anomer interconversion energy barriers. J Chromatogr A 2020; 1620:460981. [PMID: 32115232 DOI: 10.1016/j.chroma.2020.460981] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Revised: 02/11/2020] [Accepted: 02/15/2020] [Indexed: 12/31/2022]
Abstract
A new commercially available HPLC column, poly-N-(1H-tetrazole-5-yl)-methacrylamide-bonded stationary phase (Daicel DCpak PTZ), was systematically evaluated for its carbohydrate isomer separation capability by hydrophilic interaction liquid chromatography (HILIC) with charged aerosol detection (CAD) or (tandem) mass spectrometry. Reducing sugars tend to split into two anomer peaks which makes carbohydrate isomer separations in non-derivatized form even more complicated. For practical purposes anomer separations are therefore ideally suppressed which can be accomplished by using high temperature or high pH that are both associated with fast interconversion kinetics leading to peak coalescence, or on the other hand by conditions with low chromatographic anomer selectivity. Four major hexoses (glucose, mannose, galactose, fructose), five main pentoses (ribose, ribulose, xylose, xylulose, arabinose) and five most important disaccharides (maltose, cellobiose, lactose, sucrose, trehalose) were analyzed as single carbohydrate standards by isocratic HILIC with 0.1% (v/v) formic acid and 2 mM ammonium acetate at various temperatures to study anomer interconversion equilibria in a pH-dependent manner. Rate constants of forward (α→β) and backward (β→α) anomerization and corresponding energy barriers were calculated. The energy barriers of anomerisation were in the range of around 83-91 kJ mol-1 at 298 K and the difference between forward (α→β) and backward reaction (β→α) was typically between 1-3 kJ mol-1. The systematic studies finally allowed to pick conditions for the simultaneous analysis of all 14 carbohydrates by HILIC-ESI-MS(/MS) with PTZ in gradient elution mode. A combination of carbohydrate isomer-selective LC (with PTZ), tandem MS (with carbohydrate group-selective MS1 and some species-specific SRM transitions) and a simple deconvolution strategy allowed the determination of all carbohydrates of the complex test mixture except for the disaccharide pair lactose and maltose (which can be determined as sum). Consequently, the proposed method represents a successful step towards a global glycometabolomics profiling method of mono- and disaccharides by HILIC-ESI-MS/MS.
Collapse
Affiliation(s)
- Xiaoqing Fu
- Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany
| | - Malgorzata Cebo
- Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany
| | - Tohru Ikegami
- Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany; Department of Materials Synthesis, Faculty of Molecular Chemistry and Engineering, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto 606-8585, Japan.
| | - Michael Lämmerhofer
- Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany.
| |
Collapse
|
16
|
Luo Q, Ren X, Wei S, Zheng Y, Gao D, Fu Q, Xia Z, Wang L. Preparation and evaluation of a molybdenum disulfide quantum dots embedded C18 mixed-mode chromatographic stationary phase. Anal Bioanal Chem 2020; 412:1365-1374. [DOI: 10.1007/s00216-019-02363-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Revised: 12/13/2019] [Accepted: 12/18/2019] [Indexed: 12/26/2022]
|
17
|
Pitsch J, Weghuber J. Hydrophilic Interaction Chromatography Coupled with Charged Aerosol Detection for Simultaneous Quantitation of Carbohydrates, Polyols and Ions in Food and Beverages. Molecules 2019; 24:molecules24234333. [PMID: 31783530 PMCID: PMC6930467 DOI: 10.3390/molecules24234333] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2019] [Revised: 11/21/2019] [Accepted: 11/22/2019] [Indexed: 11/20/2022] Open
Abstract
Here, we report an accurate and versatile method for the simultaneous determination of 17 sugars (arabinose, erythrose, fructose, galactose, glucose, isomaltulose, lactose, lyxose, maltose, maltotriose, mannose, raffinose, rhamnose, ribose, sucrose, sorbose and xylose), seven polyols (erythritol, inositol, lactitol, maltitol, mannitol, sorbitol and xylitol), five ions (K+, Br−, Cl−, NO3− and SO42−) and the pseudosaccharide acarbose. For compound separation, hydrophilic interaction chromatography (HILIC) coupled to a corona charged aerosol detector (CAD) was used. The method was validated for linearity, precision, reproducibility, retention factor and optimal injection volume. Standards were measured in the range of 1–1000 mg L−1 and showed good intraday and interday repeatability, as well as precision (relative standard deviation (RSD) < 5%). The LODs and LOQs for the 30 analytes were in the range of 0.032–2.675 mg L−1 and 0.107–8.918 mg L−1, respectively. This method exhibited correlation coefficients of at least R2 > 0.97 for all analytes. The method was tested in 24 food and beverage samples to validate the separation efficiency and sensitivity in natural food matrices and to show the practicability of its use for routine food analysis.
Collapse
Affiliation(s)
- Johannes Pitsch
- FFoQSI-Austrian Competence Centre for Feed and Food Quality, Safety & Innovation, Head Office, FFoQSI GmbH, Technopark 1C, 3430 Tulln, Austria;
- Center of Excellence—Food Technology and Nutrition, University of Applied Sciences Upper Austria, 4600 Wels, Austria
| | - Julian Weghuber
- FFoQSI-Austrian Competence Centre for Feed and Food Quality, Safety & Innovation, Head Office, FFoQSI GmbH, Technopark 1C, 3430 Tulln, Austria;
- Center of Excellence—Food Technology and Nutrition, University of Applied Sciences Upper Austria, 4600 Wels, Austria
- Correspondence: ; Tel.: +43-50804-44403
| |
Collapse
|
18
|
Mixed-mode liquid chromatography for the rapid analysis of biocatalytic glucaric acid reaction pathways. Anal Chim Acta 2019; 1066:136-145. [DOI: 10.1016/j.aca.2019.03.023] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2018] [Revised: 03/08/2019] [Accepted: 03/12/2019] [Indexed: 01/25/2023]
|
19
|
Stable-bond polymeric reversed-phase/weak anion-exchange mixed-mode stationary phases obtained by simultaneous functionalization and crosslinking of a poly(3-mercaptopropyl)methylsiloxane-film on vinyl silica via thiol-ene double click reaction. J Chromatogr A 2019; 1593:110-118. [DOI: 10.1016/j.chroma.2019.01.078] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2018] [Revised: 01/17/2019] [Accepted: 01/31/2019] [Indexed: 02/07/2023]
|
20
|
Fabino Carr A, Patel DC, Lopez D, Armstrong DW, Ryzhov V. Comparison of reversed-phase, anion-exchange, and hydrophilic interaction HPLC for the analysis of nucleotides involved in biological enzymatic pathways. J LIQ CHROMATOGR R T 2019. [DOI: 10.1080/10826076.2019.1587622] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Allison Fabino Carr
- Department of Chemistry and Biochemistry, Northern Illinois University, Dekalb, IL, USA
| | - Darshan C. Patel
- Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, TX, USA
- Process Research & Development, AbbVie Inc, North Chicago, IL, USA
| | - Diego Lopez
- Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, TX, USA
- AZYP LLC, Arlington, TX, USA
| | - Daniel W. Armstrong
- Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, TX, USA
| | - Victor Ryzhov
- Department of Chemistry and Biochemistry, Northern Illinois University, Dekalb, IL, USA
| |
Collapse
|
21
|
Schwaiger-Haber M, Hermann G, El Abiead Y, Rampler E, Wernisch S, Sas K, Pennathur S, Koellensperger G. Proposing a validation scheme for 13C metabolite tracer studies in high-resolution mass spectrometry. Anal Bioanal Chem 2019; 411:3103-3113. [PMID: 30972471 PMCID: PMC6526147 DOI: 10.1007/s00216-019-01773-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2018] [Revised: 02/25/2019] [Accepted: 03/08/2019] [Indexed: 12/31/2022]
Abstract
13C metabolite tracer and metabolic flux analyses require upfront experimental planning and validation tools. Here, we present a validation scheme including a comparison of different LC methods that allow for customization of analytical strategies for tracer studies with regard to the targeted metabolites. As the measurement of significant changes in labeling patterns depends on the spectral accuracy, we investigate this aspect comprehensively for high-resolution orbitrap mass spectrometry combined with reversed-phase chromatography, hydrophilic interaction liquid chromatography, or anion-exchange chromatography. Moreover, we propose a quality control protocol based on (1) a metabolite containing selenium to assess the instrument performance and on (2) in vivo synthesized isotopically enriched Pichia pastoris to validate the accuracy of carbon isotopologue distributions (CIDs), in this case considering each isotopologue of a targeted metabolite panel. Finally, validation involved a thorough assessment of procedural blanks and matrix interferences. We compared the analytical figures of merit regarding CID determination for over 40 metabolites between the three methods. Excellent precisions of less than 1% and trueness bias as small as 0.01-1% were found for the majority of compounds, whereas the CID determination of a small fraction was affected by contaminants. For most compounds, changes of labeling pattern as low as 1% could be measured. Graphical abstract.
Collapse
Affiliation(s)
- Michaela Schwaiger-Haber
- Department of Analytical Chemistry, Faculty of Chemistry, University of Vienna, Waehringer Str. 38, 1090, Vienna, Austria.,Division of Nephrology, Department of Internal Medicine, University of Michigan, 1000 Wall St., Ann Arbor, MI, 48105, USA
| | - Gerrit Hermann
- Department of Analytical Chemistry, Faculty of Chemistry, University of Vienna, Waehringer Str. 38, 1090, Vienna, Austria.,ISOtopic solutions, Waehringer Str. 38, 1090, Vienna, Austria
| | - Yasin El Abiead
- Department of Analytical Chemistry, Faculty of Chemistry, University of Vienna, Waehringer Str. 38, 1090, Vienna, Austria.,Vienna Metabolomics Center (VIME), University of Vienna, Althanstraße 14, 1090, Vienna, Austria.,Chemistry Meets Microbiology, Althanstraße 14, 1090, Vienna, Austria
| | - Evelyn Rampler
- Department of Analytical Chemistry, Faculty of Chemistry, University of Vienna, Waehringer Str. 38, 1090, Vienna, Austria.,Vienna Metabolomics Center (VIME), University of Vienna, Althanstraße 14, 1090, Vienna, Austria.,Chemistry Meets Microbiology, Althanstraße 14, 1090, Vienna, Austria
| | - Stefanie Wernisch
- Division of Nephrology, Department of Internal Medicine, University of Michigan, 1000 Wall St., Ann Arbor, MI, 48105, USA
| | - Kelli Sas
- Division of Nephrology, Department of Internal Medicine, University of Michigan, 1000 Wall St., Ann Arbor, MI, 48105, USA
| | - Subramaniam Pennathur
- Division of Nephrology, Department of Internal Medicine, University of Michigan, 1000 Wall St., Ann Arbor, MI, 48105, USA.,Department of Molecular and Integrative Physiology, University of Michigan, 1000 Wall St, Ann Arbor, MI, 48105, USA
| | - Gunda Koellensperger
- Department of Analytical Chemistry, Faculty of Chemistry, University of Vienna, Waehringer Str. 38, 1090, Vienna, Austria. .,Vienna Metabolomics Center (VIME), University of Vienna, Althanstraße 14, 1090, Vienna, Austria. .,Chemistry Meets Microbiology, Althanstraße 14, 1090, Vienna, Austria.
| |
Collapse
|
22
|
Gika H, Virgiliou C, Theodoridis G, Plumb RS, Wilson ID. Untargeted LC/MS-based metabolic phenotyping (metabonomics/metabolomics): The state of the art. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1117:136-147. [PMID: 31009899 DOI: 10.1016/j.jchromb.2019.04.009] [Citation(s) in RCA: 109] [Impact Index Per Article: 18.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2019] [Revised: 04/01/2019] [Accepted: 04/03/2019] [Indexed: 12/25/2022]
Abstract
Liquid chromatography (LC) hyphenated to mass spectrometry is currently the most widely used means of determining metabolic phenotypes via both untargeted and targeted analysis. At present a range of analytical separations, including reversed-phase, hydrophilic interaction and ion-pair LC are employed to maximise metabolome coverage with ultra (high) performance liquid chromatography (UHPLC) increasingly displacing conventional high performance liquid chromatography because of the need for short analysis times and high peak capacity in such applications. However, it is widely recognized that these methodologies do not entirely solve the problems facing researchers trying to perform comprehensive metabolic phenotyping and in addition to these "routine" approaches there are continuing investigations of alternative separation methods including 2-dimensional/multi column approaches. These involve either new stationary phases or multidimensional combinations of the more conventional materials currently used, as well as application of miniaturization or "new" approaches such as supercritical HP and UHP- chromatographic separations. There is also a considerable amount of interest in the combination of chromatographic and ion mobility separations, with the latter providing both an increase in resolution and the potential to provide additional structural information via the determination of molecular collision cross section data. However, key problems remain to be solved including ensuring quality, comparability across different laboratories and the ever present difficulty of identifying unknowns.
Collapse
Affiliation(s)
- Helen Gika
- Department of Medicine, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece; Biomic AUTh, Center for Interdisciplinary Research and Innovation (CIRI-AUTH), Balkan Center B1.4, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, GR 57001 Thessaloniki, Greece; FoodOmicsGR Research Infrastructure, Center for Interdisciplinary Research and Innovation (CIRI-AUTH), Balkan Center B1.4, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, GR 57001 Thessaloniki, Greece
| | - Christina Virgiliou
- Biomic AUTh, Center for Interdisciplinary Research and Innovation (CIRI-AUTH), Balkan Center B1.4, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, GR 57001 Thessaloniki, Greece; FoodOmicsGR Research Infrastructure, Center for Interdisciplinary Research and Innovation (CIRI-AUTH), Balkan Center B1.4, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, GR 57001 Thessaloniki, Greece; Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - Georgios Theodoridis
- Biomic AUTh, Center for Interdisciplinary Research and Innovation (CIRI-AUTH), Balkan Center B1.4, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, GR 57001 Thessaloniki, Greece; FoodOmicsGR Research Infrastructure, Center for Interdisciplinary Research and Innovation (CIRI-AUTH), Balkan Center B1.4, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, GR 57001 Thessaloniki, Greece; Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | | | - Ian D Wilson
- Division of Computational and Systems Medicine, Department of Surgery and Cancer, Imperial College, Exhibition Road, South Kensington, London SW7 2AZ, UK.
| |
Collapse
|
23
|
Hydrophilic probe in mesoporous pore for selective enrichment of endogenous glycopeptides in biological samples. Anal Chim Acta 2018; 1024:84-92. [DOI: 10.1016/j.aca.2018.04.030] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Revised: 04/13/2018] [Accepted: 04/14/2018] [Indexed: 12/30/2022]
|
24
|
Multitargeted hydrophilic interaction chromatography-MS/MS: limitations and perspectives. Bioanalysis 2018; 10:1165-1167. [DOI: 10.4155/bio-2018-0147] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
|
25
|
Hsiao JJ, Potter OG, Chu TW, Yin H. Improved LC/MS Methods for the Analysis of Metal-Sensitive Analytes Using Medronic Acid as a Mobile Phase Additive. Anal Chem 2018; 90:9457-9464. [PMID: 29976062 DOI: 10.1021/acs.analchem.8b02100] [Citation(s) in RCA: 84] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Phosphorylated compounds and organic acids with multiple carboxylate groups are commonly observed to have poor peak shapes and signal in LC/MS experiments. The poor peak shape is caused by the presence of trace metals, particularly iron, contributed from a variety of sources within the chromatographic system. To ameliorate this problem, different solvent additives were investigated to reduce the amount of metal in the flow path to achieve better analytical performance for these metal-sensitive compounds. Here, we introduce the use of a solvent additive that can significantly improve the peak shapes and signal of metal-sensitive metabolites for LC/MS analysis. Moreover, the additive is shown to be amenable for other metal-sensitive applications, such as the analysis of phosphopeptides and polar phosphorylated pesticides, where the instruments could be used in either positive or negative analysis mode.
Collapse
Affiliation(s)
- Jordy J Hsiao
- Agilent Technologies, Santa Clara , California 95051 , United States
| | - Oscar G Potter
- Agilent Technologies, Santa Clara , California 95051 , United States
| | - Te-Wei Chu
- Agilent Technologies, Santa Clara , California 95051 , United States
| | - Hongfeng Yin
- Agilent Technologies, Santa Clara , California 95051 , United States
| |
Collapse
|
26
|
N-Propyl-N'-2-pyridylurea-modified silica as mixed-mode stationary phase with moderate weak anion exchange capacity and pH-dependent surface charge reversal. J Chromatogr A 2018; 1560:45-54. [PMID: 29789171 DOI: 10.1016/j.chroma.2018.05.012] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2018] [Revised: 04/30/2018] [Accepted: 05/07/2018] [Indexed: 01/25/2023]
Abstract
Herein, we present a novel silica-based stationary phase modified with N-propyl-N'-2-pyridylurea selector. Due to the weakly basic properties of the pyridine selector and the presence of residual silanols after selector immobilization, a zwitterionic surface with a pI observed at approximately pH 5.5 was measured by electrophoretic light scattering in pH-dependent ζ-potential determinations. The capability of the new N-propyl-N'-2-pyridylurea-modified silica to serve as mixed-mode stationary phase was investigated. For this purpose, it was characterized under RP and HILIC conditions using test mixtures. Subsequent classification of this stationary phase in comparison to in-house and commercial benchmarks was carried by principal component analysis of resultant retention factors from chromatographic tests. The results show a relatively unique mixed-mode character amongst the tested stationary phases. The chromatographic retention characteristics of acidic compounds matched well the ζ-potential determinations. The application of anion-exchange at low pH values (e.g. pH 5) and ion exclusion chromatography at pH 7 for the separation of uridine 5'-mono-, di- and triphosphate demonstrated a pH-dependent umpolung of the stationary phase surface. The combination of these separation principles in a pH gradient from 5 to 7 gave rise to weak anion-exchange selectivity with a charge-inducted elution due to repulsive interactions at higher pH and resulted in a significant faster separation with improved peak shape under mild elution conditions.
Collapse
|
27
|
Calderón C, Santi C, Lämmerhofer M. Chiral separation of disease biomarkers with 2-hydroxycarboxylic acid structure. J Sep Sci 2017; 41:1224-1231. [DOI: 10.1002/jssc.201701243] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Revised: 11/25/2017] [Accepted: 11/25/2017] [Indexed: 11/11/2022]
Affiliation(s)
- Carlos Calderón
- Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis; University of Tübingen; Tübingen Germany
| | - Cristina Santi
- Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis; University of Tübingen; Tübingen Germany
- Dipartimento di Chimica e Tecnologia del Farmaco; Università degli Studi di Perugia; Perugia Italy
| | - Michael Lämmerhofer
- Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis; University of Tübingen; Tübingen Germany
| |
Collapse
|
28
|
Liu J, Li J, Zheng J, Wang C. Quantitative analysis of acid-catalyzed levulinic acid product mixture from cellulose by mixed-mode liquid chromatography. Carbohydr Polym 2017; 173:150-156. [PMID: 28732853 DOI: 10.1016/j.carbpol.2017.05.095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2017] [Revised: 05/24/2017] [Accepted: 05/30/2017] [Indexed: 10/19/2022]
Abstract
A mixed-mode weak anion-exchange/reversed-phase liquid chromatography (LC) column was successfully applied for the analysis of levulinic acid (4-oxopentanoic acid, LA) product mixture derived from cellulose. Due to the existence of ionic and neutral byproducts, the analysis of the product mixture usually requires ion chromatography, LC and gas chromatography simultaneously. The new method enables accomplishment of the analysis in one LC run within 6min. LC mobile phase of 10mM phosphate buffer containing 5% acetonitrile with pH=5.5 was used. The linear regression coefficients for the UV signal of standard compounds with the corresponding mass concentrations were greater than 0.999. The method recoveries were between 98.57-103.48%. The limits of quantification were 5, 10,1000, 1500 and 3000ng/mL for 5-hydroxymethylfurfural, furfural, acetic acid, formic acid and LA respectively. The mixed-mode column exhibits comprehensive separation mechanism of both reversed-phase and ion-exchange interactions. The mobile phase with different pH, organic modifier solvent and buffer concentration provided flexible LC method for the sample with different complexity.
Collapse
Affiliation(s)
- Junyan Liu
- Sinopec Shanghai Research Institute of Petrochemical Technology, 1658 Pudong Beilu, Shanghai 201208, China.
| | - Jiwen Li
- Sinopec Shanghai Research Institute of Petrochemical Technology, 1658 Pudong Beilu, Shanghai 201208, China
| | - Junlin Zheng
- Sinopec Shanghai Research Institute of Petrochemical Technology, 1658 Pudong Beilu, Shanghai 201208, China
| | - Chuan Wang
- Sinopec Shanghai Research Institute of Petrochemical Technology, 1658 Pudong Beilu, Shanghai 201208, China
| |
Collapse
|
29
|
Aral H, Çelik KS, Altındağ R, Aral T. Synthesis, characterization, and application of a novel multifunctional stationary phase for hydrophilic interaction/reversed phase mixed-mode chromatography. Talanta 2017; 174:703-714. [PMID: 28738646 DOI: 10.1016/j.talanta.2017.07.014] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2017] [Revised: 07/01/2017] [Accepted: 07/01/2017] [Indexed: 11/28/2022]
Abstract
A novel multifunctional stationary phase based on silica gel was synthesised starting from L- isoleucine and 4-phenylbutylamine and evaluated as a hydrophilic interaction/reversed-phase mixed-mode stationary phase for high-performance liquid chromatography (HPLC). The prepared stationary phase was characterized by elemental analysis, infrared spectroscopy (IR), scanning electron microscopy (SEM), Brunauer, Emmett and Teller (BET) and solid-state 13C nuclear magnetic resonance (NMR). The mechanisms involved in the chromatographic separation are multi-interaction, including hydrophobic, π-π, hydrogen-bonding, dipole-dipole and ion-dipole interactions. Based on these interactions, successful separation could be achieved among several aromatic compounds having different polarities under both hydrophilic interaction liquid chromatography (HILIC) and reversed phase (RP) condition. Nucleotides/nucleosides were separated in the HILIC mode. The effects of different separation conditions, such as pH value, mobile-phase content, column temperature, buffer concentration and flow rate, on the separation of nucleotides/nucleosides in HILIC mode were investigated. The seven nucleotides/nucleosides were separated within 22min, while six of them were separated within 10min by isocratic elution. To determine the influence of the new multifunctional stationary phase under the RP condition, a number of moderately and weakly polar and nonpolar compounds, such as 10 substituted anilines and eight substituted phenols were separated successfully under the RP condition within 14 and 15min, respectively. Additionally, nine mixtures of polar/nonpolar test compounds were simultaneously separated within 19min, while seven of them were separated within 12min, under HILIC/RP mixed-mode conditions. Chromatographic parameters, such as the retention factor and peak asymmetry factor, were calculated for all of the analytes, while the theoretical plate number was calculated for analytes separated by isocratic elution. Compared to traditional C18 and commercial HILIC columns, the new stationary phase exhibited both HILIC and RPLC performance, and the scope of analyte separation was thus enlarged.
Collapse
Affiliation(s)
- Hayriye Aral
- University of Batman, Faculty of Science and Art, Department of Chemistry, Batman, Turkey
| | - K Serdar Çelik
- University of Batman, Faculty of Science and Art, Department of Chemistry, Batman, Turkey
| | - Ramazan Altındağ
- University of Batman, Faculty of Science and Art, Department of Chemistry, Batman, Turkey
| | - Tarık Aral
- University of Batman, Faculty of Science and Art, Department of Chemistry, Batman, Turkey.
| |
Collapse
|
30
|
Mathon C, Barding GA, Larive CK. Separation of ten phosphorylated mono-and disaccharides using HILIC and ion-pairing interactions. Anal Chim Acta 2017; 972:102-110. [DOI: 10.1016/j.aca.2017.03.029] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2017] [Revised: 03/05/2017] [Accepted: 03/09/2017] [Indexed: 10/19/2022]
|
31
|
Matsuda F. Technical Challenges in Mass Spectrometry-Based Metabolomics. ACTA ACUST UNITED AC 2016; 5:S0052. [PMID: 27900235 DOI: 10.5702/massspectrometry.s0052] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2016] [Accepted: 10/05/2016] [Indexed: 12/15/2022]
Abstract
Metabolomics is a strategy for analysis, and quantification of the complete collection of metabolites present in biological samples. Metabolomics is an emerging area of scientific research because there are many application areas including clinical, agricultural, and medical researches for the biomarker discovery and the metabolic system analysis by employing widely targeted analysis of a few hundred preselected metabolites from 10-100 biological samples. Further improvement in technologies of mass spectrometry in terms of experimental design for larger scale analysis, computational methods for tandem mass spectrometry-based elucidation of metabolites, and specific instrumentation for advanced bioanalysis will enable more comprehensive metabolome analysis for exploring the hidden secrets of metabolism.
Collapse
Affiliation(s)
- Fumio Matsuda
- Department of Bioinformatic Engineering, Graduate School of Information Science and Technology, Osaka University; RIKEN Center for Sustainable Resource Science
| |
Collapse
|
32
|
Zhang K, Liu X. Reprint of “Mixed-mode chromatography in pharmaceutical and biopharmaceutical applications”. J Pharm Biomed Anal 2016; 130:19-34. [DOI: 10.1016/j.jpba.2016.09.013] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2016] [Revised: 05/04/2016] [Accepted: 05/05/2016] [Indexed: 01/31/2023]
|
33
|
Zhang L, Dai Q, Qiao X, Yu C, Qin X, Yan H. Mixed-mode chromatographic stationary phases: Recent advancements and its applications for high-performance liquid chromatography. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.05.011] [Citation(s) in RCA: 67] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
34
|
Ortmayr K, Causon TJ, Hann S, Koellensperger G. Increasing selectivity and coverage in LC-MS based metabolome analysis. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.06.011] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
35
|
Meissen JK, Pirman DA, Wan M, Miller E, Jatkar A, Miller R, Steenwyk RC, Blatnik M. Phenotyping hepatocellular metabolism using uniformly labeled carbon-13 molecular probes and LC-HRMS stable isotope tracing. Anal Biochem 2016; 508:129-37. [DOI: 10.1016/j.ab.2016.06.019] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2016] [Revised: 06/17/2016] [Accepted: 06/20/2016] [Indexed: 10/21/2022]
|
36
|
Wang H, Zhang L, Ma T, Zhang L, Qiao X. Imidazolium‐embedded iodoacetamide‐functionalized silica‐based stationary phase for hydrophilic interaction/reversed‐phase mixed‐mode chromatography. J Sep Sci 2016; 39:3498-504. [DOI: 10.1002/jssc.201600448] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2016] [Revised: 07/12/2016] [Accepted: 07/12/2016] [Indexed: 11/06/2022]
Affiliation(s)
- Huizhen Wang
- Electrical and Information Engineering Department of Hebei Jiaotong Vocational & Technical College Shijiazhuang China
| | - Lu Zhang
- Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, College of Pharmaceutical SciencesHebei University Baoding China
| | - Teng Ma
- Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, College of Pharmaceutical SciencesHebei University Baoding China
| | - Liyuan Zhang
- Liaoning Provincial Key Laboratory for ProteomicsDalian Medical University Dalian China
| | - Xiaoqiang Qiao
- Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, College of Pharmaceutical SciencesHebei University Baoding China
| |
Collapse
|
37
|
Recent advances in materials for stationary phases of mixed-mode high-performance liquid chromatography. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.04.001] [Citation(s) in RCA: 74] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
38
|
Mixed-mode chromatography in pharmaceutical and biopharmaceutical applications. J Pharm Biomed Anal 2016; 128:73-88. [PMID: 27236100 DOI: 10.1016/j.jpba.2016.05.007] [Citation(s) in RCA: 123] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2016] [Revised: 05/04/2016] [Accepted: 05/05/2016] [Indexed: 01/19/2023]
Abstract
Mixed-mode chromatography (MMC) is a fast growing area in recent years, thanks to the new generation of mixed-mode stationary phases and better understanding of multimode interactions. MMC has superior applications in the separation of compounds that are not retained or not well resolved by typical reversed-phase LC methods, especially for polar and charged molecules. Due to the multiple retention modes that a single MMC column can offer, often MMC provides additional dimension to a separation method by adjusting the mobile phase conditions. Mixed-mode media is also an effective way to clean up complex sample matrices for purification purposes or for sensitive detection of trace amounts of analytes. In this article, we discuss mixed-mode stationary phases and separation mechanisms and review recent advances in pharmaceutical and biopharmaceutical applications including the analysis and/or purification of counterions, small molecule drugs, impurities, formulation excipients, peptides and proteins.
Collapse
|
39
|
Wang P, Wang Q, Yang B, Zhao S, Kuang H. The Progress of Metabolomics Study in Traditional Chinese Medicine Research. THE AMERICAN JOURNAL OF CHINESE MEDICINE 2015; 43:1281-310. [DOI: 10.1142/s0192415x15500731] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Traditional Chinese medicine (TCM) has played important roles in health protection and disease treatment for thousands of years in China and has gained the gradual acceptance of the international community. However, many intricate issues, which cannot be explained by traditional methods, still remain, thus, new ideas and technologies are needed. As an emerging system biology technology, the holistic view adopted by metabolomics is similar to that of TCM, which allows us to investigate TCM with complicated conditions and multiple factors in depth. In this paper, we tried to give a timely and comprehensive update about the methodology progression of metabolomics, as well as its applications, in different fields of TCM studies including quality control, processing, safety and efficacy evaluation. The herbs investigated by metabolomics were selected for detailed examination, including Anemarrhena asphodeloides Bunge, Atractylodes macrocephala Kidd, Pinellia ternate, etc.; furthermore, some valuable results have been obtained and summarized. In conclusion, although the study of metabolomics is at the early phase and requires further scrutiny and validation, it still provides bright prospects to dissect the synergistic action of multiple components from TCM. Overall, with the further development of analytical techniques, especially multi-analysis techniques, we expect that metabolomics will greatly promote TCM research and the establishment of international standards, which is beneficial to TCM modernization.
Collapse
Affiliation(s)
- Pengcheng Wang
- Key Laboratory of Chinese Materia Medica (Ministry of Education), Heilongjiang University of Chinese Medicine, Harbin, P.R. China
| | - Qiuhong Wang
- Key Laboratory of Chinese Materia Medica (Ministry of Education), Heilongjiang University of Chinese Medicine, Harbin, P.R. China
| | - Bingyou Yang
- Key Laboratory of Chinese Materia Medica (Ministry of Education), Heilongjiang University of Chinese Medicine, Harbin, P.R. China
| | - Shan Zhao
- Key Laboratory of Chinese Materia Medica (Ministry of Education), Heilongjiang University of Chinese Medicine, Harbin, P.R. China
| | - Haixue Kuang
- Key Laboratory of Chinese Materia Medica (Ministry of Education), Heilongjiang University of Chinese Medicine, Harbin, P.R. China
| |
Collapse
|
40
|
Zhang J, Zhao C, Zeng Z, Luo P, Zhao Y, Zhao J, Li L, Lu X, Xu G. Sample-directed pseudotargeted method for the metabolic profiling analysis of rice seeds based on liquid chromatography with mass spectrometry. J Sep Sci 2015; 39:247-55. [PMID: 26517975 DOI: 10.1002/jssc.201500858] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2015] [Revised: 09/28/2015] [Accepted: 10/15/2015] [Indexed: 12/21/2022]
Abstract
Rice is one of the most important food crops in the world. Metabolite composition in rice seeds varies significantly depending on genetic variety, climatic alternation and agricultural practice. Metabolomics is a powerful tool to reveal the metabolic response of rice to various conditions. In this work, a rice seed sample-directed pseudotargeted metabolomics method was first established and validated based on ultra high performance liquid chromatography with triple quadrupole mass spectrometry in the multiple reaction monitoring mode. A total of 749 and 617 ion pairs in positive and negative modes were achieved, respectively. Among them, about 200 metabolites were identified or tentatively identified. The developed method showed better linearity and repeatability than those of non-targeted metabolomics method. Good intra-day and inter-day precisions, recoveries and wide linear range were also obtained. Furthermore, the method was applied for the investigation of metabolic variation of rice seeds with two wild cultivars and their transgenic lines that were grown in two locations. Principal component analysis indicated that the effects of cultivar and location on metabolic variations were far more than those of gene modification. The nonparametric Mann-Whitney U test revealed that most metabolites were influenced by cultivar, location and gene modifications together.
Collapse
Affiliation(s)
- Junjie Zhang
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China
| | - Chunxia Zhao
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China
| | - Zhongda Zeng
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China
| | - Ping Luo
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China
| | - Yanni Zhao
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China
| | - Jieyu Zhao
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China
| | - Lili Li
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China
| | - Xin Lu
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China
| | - Guowang Xu
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China
| |
Collapse
|
41
|
Lindamulage De Silva A, Risso V, Jean M, Giorgi M, Monnier V, Naubron JV, Vanthuyne N, Farran D, Roussel C. A forgotten chiral spiro compound revisited: 3,3'-dimethyl-3H,3'H-2,2'-spirobi[[1,3]benzothiazole]. Chirality 2015; 27:716-21. [PMID: 26415851 DOI: 10.1002/chir.22492] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2015] [Revised: 07/06/2015] [Accepted: 07/09/2015] [Indexed: 11/09/2022]
Abstract
The title compound was obtained as a side product during dimerization-oxidation steps of the carbene generated from N-methylbenzothiazolium iodide. Chromatography on (S,S)-Whelk O1 column showed on cooling a typical plateau shape chromatogram indicating an exchange between two enantiomers on the column. The thermal barrier to racemization was determined (85 kJ.mol(-1) at 10 °C) by dynamic high-performance liquid chromatography (DHPLC).The absolute configuration of the first (M) and second eluted (P) enantiomers on the (S, S)-Whelk O1 column was established by comparing the reconstructed circular dichroism (CD) spectra from the CD detector signal and the calculated CD spectrum of the (P) enantiomer. Mass spectrometry revealed that 3,3'-dimethyl-3H,3'H-2,2'-spirobi[[1,3]benzothiazole] can be viewed as a masked thiophenate attached to a benzothiazolium framework.
Collapse
Affiliation(s)
| | - Vesna Risso
- Aix Marseille Université, Centrale Marseille, CNRS, iSm2 UMR 7313, 13397, Marseille, France
| | - Marion Jean
- Aix Marseille Université, Centrale Marseille, CNRS, iSm2 UMR 7313, 13397, Marseille, France
| | - Michel Giorgi
- Spectropôle, Aix Marseille Université, Marseille, France
| | | | | | - Nicolas Vanthuyne
- Aix Marseille Université, Centrale Marseille, CNRS, iSm2 UMR 7313, 13397, Marseille, France
| | - Daniel Farran
- Aix Marseille Université, Centrale Marseille, CNRS, iSm2 UMR 7313, 13397, Marseille, France
| | - Christian Roussel
- Aix Marseille Université, Centrale Marseille, CNRS, iSm2 UMR 7313, 13397, Marseille, France
| |
Collapse
|
42
|
Eastwood H, Xia F, Lo MC, Zhou J, Jordan JB, McCarter J, Barnhart WW, Gahm KH. Development of a nucleotide sugar purification method using a mixed mode column & mass spectrometry detection. J Pharm Biomed Anal 2015; 115:402-9. [PMID: 26279371 DOI: 10.1016/j.jpba.2015.08.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2015] [Revised: 07/31/2015] [Accepted: 08/01/2015] [Indexed: 10/23/2022]
Abstract
Analysis of nucleotide sugars, nucleoside di- and triphosphates and sugar-phosphates is an essential step in the process of understanding enzymatic pathways. A facile and rapid separation method was developed to analyze these compounds present in an enzymatic reaction mixture utilized to produce nucleotide sugars. The Primesep SB column explored in this study utilizes hydrophobic interactions as well as electrostatic interactions with the phosphoric portion of the nucleotide sugars. Ammonium formate buffer was selected due to its compatibility with mass spectrometry. Negative ion mode mass spectrometry was adopted for detection of the sugar phosphate (fucose-1-phophate), as the compound is not amenable to UV detection. Various mobile phase conditions such as pH, buffer concentration and organic modifier were explored. The semi-preparative separation method was developed to prepare 30mg of the nucleotide sugar. (19)F NMR was utilized to determine purity of the purified fluorinated nucleotide sugar. The collected nucleotide sugar was found to be 99% pure.
Collapse
Affiliation(s)
- Heather Eastwood
- Department of Molecular Structure & Characterization, Amgen, Inc., Thousand Oaks, CA 91320, United States.
| | - Fang Xia
- ASK-Gene Pharma, Inc., Camarillo, CA 93012, United States
| | - Mei-Chu Lo
- Department of Molecular Structure & Characterization, Amgen, Inc., Thousand Oaks, CA 91320, United States
| | - Jing Zhou
- Department of Molecular Structure & Characterization, Amgen, Inc., Thousand Oaks, CA 91320, United States
| | - John B Jordan
- Department of Molecular Structure & Characterization, Amgen, Inc., Thousand Oaks, CA 91320, United States
| | - John McCarter
- Department of Molecular Structure & Characterization, Amgen, Inc., Thousand Oaks, CA 91320, United States
| | - Wesley W Barnhart
- Department of Molecular Structure & Characterization, Amgen, Inc., Thousand Oaks, CA 91320, United States
| | - Kyung-Hyun Gahm
- Department of Molecular Structure & Characterization, Amgen, Inc., Thousand Oaks, CA 91320, United States
| |
Collapse
|
43
|
Zimmermann A, Horak J, Sánchez-Muñoz OL, Lämmerhofer M. Surface charge fine tuning of reversed-phase/weak anion-exchange type mixed-mode stationary phases for milder elution conditions. J Chromatogr A 2015. [DOI: 10.1016/j.chroma.2015.07.036] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
44
|
Klavins K, Chu DB, Hann S, Koellensperger G. Fully automated on-line two-dimensional liquid chromatography in combination with ESI MS/MS detection for quantification of sugar phosphates in yeast cell extracts. Analyst 2015; 139:1512-20. [PMID: 24471156 DOI: 10.1039/c3an01930f] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
A mass spectrometric quantitative assay was developed for the analysis of 10 sugar phosphates in the yeast Pichia pastoris. As a novelty, two-dimensional chromatography based on a fully automated heart-cutting LC-LC technique was introduced. Using a ten-port valve, ten fractions of the first chromatographic dimension, i.e. anion exchange chromatography (AEC), were transferred and separated by the orthogonal second dimension, i.e. separation on porous graphitized carbon. The chromatographic separation on the second dimension was optimized for each transferred fraction minimizing the separation time and ensuring complete removal of the salt constituents of the AEC eluents. The latter being crucial for electrospray mass spectrometric detection was confirmed by combining the LC-LC separation with on-line ICP-MS detection. These measurements showed that sodium elution was completed after 0.8 min. Consequently, an analysis time of 1 min per transferred peak was established. In this way, the excellent peak capacity given by ion exchange could be conserved in the second dimension at the same time enabling mass spectrometric detection. Sub-μM limits of detection could be obtained by the new LC-LC-MS/MS methods ranging between 0.03 and 0.19 μM for the investigated compounds (only 3GAP showed a LOD of 1 μM). The method was applied to the quantification of ten sugar phosphates in yeast extracts utilizing internal standardization with a fully labeled (13)C yeast extract. Typically, the standard uncertainties for N = 3 replicates assessed by the LC-LC-MS/MS set-up were <5%.
Collapse
Affiliation(s)
- Kristaps Klavins
- University of Natural Resources and Life Sciences, BOKU-Vienna, Department of Chemistry, Division of Analytical Chemistry, Muthgasse 18, 1190, Vienna, Austria.
| | | | | | | |
Collapse
|
45
|
Balkatzopoulou P, Fasoula S, Gika H, Nikitas P, Pappa-Louisi A. Retention prediction of highly polar ionizable solutes under gradient conditions on a mixed-mode reversed-phase and weak anion-exchange stationary phase. J Chromatogr A 2015; 1396:72-6. [PMID: 25900744 DOI: 10.1016/j.chroma.2015.03.082] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2015] [Revised: 03/30/2015] [Accepted: 03/30/2015] [Indexed: 12/01/2022]
Abstract
In the present work the retention of three highly polar and ionizable solutes - uric acid, nicotinic acid and ascorbic acid - was investigated on a mixed-mode reversed-phase and weak anion-exchange (RP/WAX) stationary phase in buffered aqueous acetonitrile (ACN) mobile phases. A U-shaped retention behavior was observed for all solutes with respect to the eluent organic modifier content studied in a range of 5-95% (v/v). This retention behavior clearly demonstrates the presence of a HILIC-type retention mechanism at ACN-rich hydro-organic eluents and an RP-like retention at aqueous-rich hydro-organic eluents. Hence, this column should be promising for application under both RP and HILIC gradient elution modes. For this reason, a series of programmed elution runs were carried out with increasing (RP) and decreasing (HILIC) organic solvent concentration in the mobile phase. This dual gradient process was successfully modeled by two retention models exhibiting a quadratic or a cubic dependence of the logarithm of the solute retention factor (lnk) upon the organic modifier volume fraction (φ). It was found that both models produced by gradient retention data allow the prediction of solute retention times for both types of programmed elution on the mixed-mode column. Four, in the case of the quadratic model, or five, in the case of the cubic model, initial HILIC- and RP-type gradient runs gave satisfactory retention predictions of any similar kind elution program, even with different flow rate, with an overall error of only 2.5 or 1.7%, respectively.
Collapse
Affiliation(s)
- P Balkatzopoulou
- Department of Chemistry, Aristotle University of Thessaloniki, 54124, Greece
| | - S Fasoula
- Department of Chemistry, Aristotle University of Thessaloniki, 54124, Greece
| | - H Gika
- Department of Chemical Engineering, Aristotle University of Thessaloniki, 54124, Greece
| | - P Nikitas
- Department of Chemistry, Aristotle University of Thessaloniki, 54124, Greece
| | - A Pappa-Louisi
- Department of Chemistry, Aristotle University of Thessaloniki, 54124, Greece.
| |
Collapse
|
46
|
Ortmayr K, Hann S, Koellensperger G. Complementing reversed-phase selectivity with porous graphitized carbon to increase the metabolome coverage in an on-line two-dimensional LC-MS setup for metabolomics. Analyst 2015; 140:3465-73. [PMID: 25824707 PMCID: PMC4719141 DOI: 10.1039/c5an00206k] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Efficient and robust separation methods are indispensable in modern LC-MS based metabolomics, where high-resolution mass spectrometers are challenged by isomeric and isobaric metabolites. The optimization of chromatographic separation hence remains an invaluable tool in the comprehensive analysis of the chemically diverse intracellular metabolome. While it is widely accepted that a single method with comprehensive metabolome coverage does not exist, the potential of combining different chromatographic selectivities in two-dimensional liquid chromatography is underestimated in the field. Here, we introduce a novel separation system combining reversed-phase and porous graphitized carbon liquid chromatography in a heart-cut on-line two-dimensional setup for mass spectrometry. The proposed experimental setup can be readily implemented using standard HPLC equipment with only one additional HPLC pump and a two-position six-port valve. The method proved to be robust with excellent retention time stability (average 0.4%) even in the presence of biological matrix. Testing the presented approach on a test mixture of 82 relevant intracellular metabolites, the number of metabolites that are retained could be doubled as compared to reversed-phase liquid chromatography alone. The presented work further demonstrates how the distinct selectivity of porous graphitized carbon complements reversed-phase liquid chromatography and extends the metabolome coverage of conventional LC-MS based methods in metabolomics to biologically important, but analytically challenging compound groups such as sugar phosphates. Both metabolic profiling and metabolic fingerprinting benefit from this method's increased separation capabilities that enhance sample throughput and the biological information content of LC-MS data. An inter-platform comparison with GC- and LC-tandem MS analyses confirmed the validity of the presented two-dimensional approach in the analysis of yeast cell extracts from P. pastoris.
Collapse
Affiliation(s)
- Karin Ortmayr
- Department of Chemistry, University of Natural Resources and Life Sciences (BOKU) Vienna, Muthgasse 18, 1190 Vienna, Austria
| | | | | |
Collapse
|
47
|
Wan H, Sheng Q, Zhong H, Guo X, Fu Q, Liu Y, Xue X, Liang X. Evaluation of a silicon oxynitride hydrophilic interaction liquid chromatography column in saccharide and glycoside separations. J Sep Sci 2015; 38:1271-6. [DOI: 10.1002/jssc.201401413] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2014] [Revised: 01/16/2015] [Accepted: 01/17/2015] [Indexed: 11/06/2022]
Affiliation(s)
- Huihui Wan
- Faculty of Chemical; Environmental and Biological Science and Technology; Analytical Center; Dalian University of Technology; Dalian China
| | - Qianying Sheng
- Engineering Research Center of Pharmaceutical Process Chemistry; Ministry of Education; School of Pharmacy; East China University of Science and Technology; Shanghai China
| | - Hongmin Zhong
- Faculty of Chemical; Environmental and Biological Science and Technology; Analytical Center; Dalian University of Technology; Dalian China
| | - Xiujie Guo
- Key Lab of Separation Science for Analytical Chemistry; Dalian Institute of Chemical Physics; Chinese Academy of Sciences; Dalian China
| | - Qing Fu
- Engineering Research Center of Pharmaceutical Process Chemistry; Ministry of Education; School of Pharmacy; East China University of Science and Technology; Shanghai China
| | - Yanfang Liu
- Key Lab of Separation Science for Analytical Chemistry; Dalian Institute of Chemical Physics; Chinese Academy of Sciences; Dalian China
| | - Xingya Xue
- Key Lab of Separation Science for Analytical Chemistry; Dalian Institute of Chemical Physics; Chinese Academy of Sciences; Dalian China
| | - Xinmiao Liang
- Key Lab of Separation Science for Analytical Chemistry; Dalian Institute of Chemical Physics; Chinese Academy of Sciences; Dalian China
| |
Collapse
|
48
|
Chu DB, Troyer C, Mairinger T, Ortmayr K, Neubauer S, Koellensperger G, Hann S. Isotopologue analysis of sugar phosphates in yeast cell extracts by gas chromatography chemical ionization time-of-flight mass spectrometry. Anal Bioanal Chem 2015; 407:2865-75. [PMID: 25673246 DOI: 10.1007/s00216-015-8521-9] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2014] [Revised: 01/17/2015] [Accepted: 01/27/2015] [Indexed: 01/05/2023]
Abstract
Metabolic flux analysis is based on the measurement of isotopologue ratios. In this work, a new GC-MS-based method was introduced enabling accurate determination of isotopologue distributions of sugar phosphates in cell extracts. A GC-TOFMS procedure was developed involving a two-step online derivatization (ethoximation followed by trimethylsilylation) offering high mass resolution, high mass accuracy and the potential of retrospective data analysis typical for TOFMS. The information loss due to fragmentation intrinsic for isotopologue analysis by electron ionization could be overcome by chemical ionization with methane. A thorough optimization regarding pressure of the reaction gas, emission current, electron energy and temperature of the ion source was carried out. For a substantial panel of sugar phosphates both of the glycolysis and the pentose phosphate pathway, sensitive determination of the protonated intact molecular ions together with low abundance fragment ions was successfully achieved. The developed method was evaluated for analysis of Pichia pastoris cell extracts. The measured isotopologue ratios were in the range of 55:1-2:1. The comparison of the experimental isotopologue fractions with the theoretical fractions was excellent, revealing a maximum bias of 4.6% and an average bias of 1.4%.
Collapse
Affiliation(s)
- Dinh Binh Chu
- Division of Analytical Chemistry, Department of Chemistry, University of Natural Resources and Life Sciences, BOKU Vienna, Muthgasse 18, 1190, Vienna, Austria
| | | | | | | | | | | | | |
Collapse
|
49
|
Zhu B, Liu F, Li X, Wang Y, Gu X, Dai J, Wang G, Cheng Y, Yan C. Fast quantification of endogenous carbohydrates in plasma using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry. J Sep Sci 2014; 38:34-41. [DOI: 10.1002/jssc.201400899] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2014] [Revised: 10/08/2014] [Accepted: 10/08/2014] [Indexed: 12/12/2022]
Affiliation(s)
- Bangjie Zhu
- School of Pharmacy; Shanghai Jiao Tong University; Shanghai China
| | - Feng Liu
- School of Pharmacy; Shanghai Jiao Tong University; Shanghai China
| | - Xituo Li
- School of Pharmacy; Shanghai Jiao Tong University; Shanghai China
| | - Yan Wang
- School of Pharmacy; Shanghai Jiao Tong University; Shanghai China
| | - Xue Gu
- School of Pharmacy; Shanghai Jiao Tong University; Shanghai China
| | - Jieyu Dai
- DMPK Department; HD Biosciences; Shanghai China
| | - Guiming Wang
- School of Pharmacy; Shanghai Jiao Tong University; Shanghai China
| | - Yu Cheng
- School of Pharmacy; Shanghai Jiao Tong University; Shanghai China
| | - Chao Yan
- School of Pharmacy; Shanghai Jiao Tong University; Shanghai China
| |
Collapse
|
50
|
Yin P, Xu G. Current state-of-the-art of nontargeted metabolomics based on liquid chromatography-mass spectrometry with special emphasis in clinical applications. J Chromatogr A 2014; 1374:1-13. [PMID: 25444251 DOI: 10.1016/j.chroma.2014.11.050] [Citation(s) in RCA: 83] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2014] [Revised: 11/16/2014] [Accepted: 11/17/2014] [Indexed: 12/21/2022]
Abstract
Metabolomics, as a part of systems biology, has been widely applied in different fields of life science by studying the endogenous metabolites. The development and applications of liquid chromatography (LC) coupled with high resolution mass spectrometry (MS) greatly improve the achievable data quality in non-targeted metabolic profiling. However, there are still some emerging challenges to be covered in LC-MS based metabolomics. Here, recent approaches about sample collection and preparation, instrumental analysis, and data handling of LC-MS based metabolomics are summarized, especially in the analysis of clinical samples. Emphasis is put on the improvement of analytical techniques including the combination of different LC columns, isotope coded derivatization methods, pseudo-targeted LC-MS method, new data analysis algorithms and structural identification of important metabolites.
Collapse
Affiliation(s)
- Peiyuan Yin
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| | - Guowang Xu
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.
| |
Collapse
|