1
|
Murtada K, Pawliszyn J. Evaluation of thin film microextraction based on graphene oxide/ polymer composite: Experimental and theoretical insights. Talanta 2024; 274:126032. [PMID: 38581851 DOI: 10.1016/j.talanta.2024.126032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Revised: 03/28/2024] [Accepted: 04/01/2024] [Indexed: 04/08/2024]
Abstract
Experimental and theoretical assessments of a graphene oxide-based polymer as adsorbent for thin film microextraction (TFME) were conducted as part of this research. Graphene oxide (GO) was embedded in the organic polymer poly(styrene-co-divinylbenzene) (PS-DVB) to prepare a sorbent suitable for direct-immersion TFME. A TFME membrane coating prepared with the GO/PS-DVB sorbent and polydimethylsiloxane (PDMS) as binder was then applied for extraction of organic pollutants from aqueous and gaseous samples. The surface morphology of the TFME coating was examined by scanning electron microscopy (SEM). Various TFME parameters influencing extraction efficiency, such as extraction time and temperature, desorption temperature, and ionic strength, were investigated and optimized. In a comparison of TFME membranes, the GO/PS-DVB/PDMS TFME membrane was shown to yield higher extraction efficiencies for the targeted analytes than the pure PDMS and DVB/PDMS TFME membranes. The calibration graphs of the organic pollutants displayed linearity for most of the target analytes within the 10-2000 ng L-1 concentration range. The repeatability (RSD %, n = 5) and reproducibility (RSD %, n = 3) of the method were in the ranges of 2.2-5.9 %, and 3.2-8.5 %, respectively, at a concentration level of 500 ng L-1, whereas accuracy (%) ranged between 79.8 and 119 %. The developed method was successfully applied for determinations of organic pollutants in tap water, lake water, and wastewater samples. Furthermore, the impact of mass transfer kinetics on extractions by the GO/PS-DVB/PDMS TFME membrane from gaseous samples was theoretically discussed and experimentally verified. The results of this work demonstrate that the GO/PS-DVB/PDMS TFME method is a simple, efficient, and environmentally friendly method for pre-treatment of organic pollutants.
Collapse
Affiliation(s)
- Khaled Murtada
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada.
| |
Collapse
|
2
|
Riboni N, Ribezzi E, Bianchi F, Careri M. Supramolecular Materials as Solid-Phase Microextraction Coatings in Environmental Analysis. Molecules 2024; 29:2802. [PMID: 38930867 PMCID: PMC11206577 DOI: 10.3390/molecules29122802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2024] [Revised: 06/06/2024] [Accepted: 06/08/2024] [Indexed: 06/28/2024] Open
Abstract
Solid-phase microextraction (SPME) has been widely proposed for the extraction, clean-up, and preconcentration of analytes of environmental concern. Enrichment capabilities, preconcentration efficiency, sample throughput, and selectivity in extracting target compounds greatly depend on the materials used as SPME coatings. Supramolecular materials have emerged as promising porous coatings to be used for the extraction of target compounds due to their unique selectivity, three-dimensional framework, flexible design, and possibility to promote the interaction between the analytes and the coating by means of multiple oriented functional groups. The present review will cover the state of the art of the last 5 years related to SPME coatings based on metal organic frameworks (MOFs), covalent organic frameworks (COFs), and supramolecular macrocycles used for environmental applications.
Collapse
Affiliation(s)
- Nicolò Riboni
- Department of Chemistry, Life Sciences and Environmental Sustainability, University of Parma, Parco Area Delle Scienze 17/A, 43124 Parma, Italy; (E.R.); (M.C.)
| | | | - Federica Bianchi
- Department of Chemistry, Life Sciences and Environmental Sustainability, University of Parma, Parco Area Delle Scienze 17/A, 43124 Parma, Italy; (E.R.); (M.C.)
| | | |
Collapse
|
3
|
Leszczyńska D, Hallmann A, Treder N, Bączek T, Roszkowska A. Recent advances in the use of SPME for drug analysis in clinical, toxicological, and forensic medicine studies. Talanta 2024; 270:125613. [PMID: 38159351 DOI: 10.1016/j.talanta.2023.125613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 12/21/2023] [Accepted: 12/27/2023] [Indexed: 01/03/2024]
Abstract
Solid-phase microextraction (SPME) has gained attention as a simple, fast, and non-exhaustive extraction technique, as its unique features enable its use for the extraction of many classes of drugs from biological matrices. This sample-preparation approach consolidates sampling and sample preparation into a single step, in addition to providing analyte preconcentration and sample clean-up. These features have helped SPME become an integral part of several analytical protocols for monitoring drug concentrations in human matrices in clinical, toxicological, and forensic medicine studies. Over the years, researchers have continued to develop the SPME technique, resulting in the introduction of novel sorbents and geometries, which have resulted in improved extraction efficiencies. This review summarizes developments and applications of SPME published between 2016 and 2022, specifically in relation to the analysis of central nervous system drugs, drugs used to treat cardiovascular disorders and bacterial infections, and drugs used in immunosuppressive and anticancer therapies.
Collapse
Affiliation(s)
- Dagmara Leszczyńska
- Department of Pharmaceutical Biochemistry, Medical University of Gdańsk, Gdańsk, 80-211, Poland
| | - Anna Hallmann
- Department of Pharmaceutical Biochemistry, Medical University of Gdańsk, Gdańsk, 80-211, Poland
| | - Natalia Treder
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, 80-416, Poland
| | - Tomasz Bączek
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, 80-416, Poland
| | - Anna Roszkowska
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, 80-416, Poland.
| |
Collapse
|
4
|
Woźniczka K, Konieczyński P, Plenis A, Bączek T, Roszkowska A. SPME as a green sample-preparation technique for the monitoring of phytocannabinoids and endocannabinoids in complex matrices. J Pharm Anal 2023; 13:1117-1134. [PMID: 38024858 PMCID: PMC10657972 DOI: 10.1016/j.jpha.2023.06.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Revised: 06/10/2023] [Accepted: 06/27/2023] [Indexed: 12/01/2023] Open
Abstract
The endocannabinoid system (ECS), particularly its signaling pathways and ligands, has garnered considerable interest in recent years. Along with clinical work investigating the ECS' functions, including its role in the development of neurological and inflammatory conditions, much research has focused on developing analytical protocols enabling the precise monitoring of the levels and metabolism of the most potent ECS ligands: exogenous phytocannabinoids (PCs) and endogenous cannabinoids (endocannabinoids, ECs). Solid-phase microextraction (SPME) is an advanced, non-exhaustive sample-preparation technique that facilitates the precise and efficient isolation of trace amounts of analytes, thus making it appealing for the analysis of PCs and ECs in complex matrices of plant and animal/human origin. In this paper, we review recent forensic medicine and toxicological studies wherein SPME has been applied to monitor levels of PCs and ECs in complex matrices, determine their effects on organism physiology, and assess their role in the development of several diseases.
Collapse
Affiliation(s)
- Katarzyna Woźniczka
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, Poland
| | - Paweł Konieczyński
- Department of Analytical Chemistry, Medical University of Gdańsk, Gdańsk, Poland
| | - Alina Plenis
- Department of Analytical Chemistry, Medical University of Gdańsk, Gdańsk, Poland
| | - Tomasz Bączek
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, Poland
| | - Anna Roszkowska
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, Poland
| |
Collapse
|
5
|
Murtada K, Nazdrajić E, Pawliszyn J. Performance Evaluation of Extraction Coatings with Different Sorbent Particles and Binder Composition. Anal Chem 2023; 95:12745-12753. [PMID: 37584189 DOI: 10.1021/acs.analchem.3c01462] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/17/2023]
Abstract
Binders are critical components used in the preparation of a range of extraction devices, including solid-phase microextraction (SPME) devices. While the main role of a binder is to affix the sorbent particles to the selected support, it is critical to select the optimal binder to ensure that it does not negatively impact the coating's particle sorption capability. This work presents the first comprehensive investigation of the interactions between binders and solid sorbent particles as these interactions can significantly impact the performance of the coating. Specifically, the findings presented herein provide a better understanding of the extraction mechanisms of composite coatings and new rules for predicting the particle adhesion forces and binder distribution in the coating. The influence of binder chemistry on coating performance is investigated by examining a selection of the most used binders, namely, polydimethylsiloxane (PDMS), polyacrylonitrile (PAN), poly(vinylidene difluoride) (PVDF), polytetrafluoroethylene amorphous fluoroplastics (PTFE AF 2400), and polybenzimidazole (PBI). The solid particles (e.g., hydrophilic-lipophilic balanced (HLB) and C18) used in this work were selected for their ability to provide optimal extraction coverage for a broad range of analytes. The results show that PDMS does not change the properties of the solid particles and that the binder occupies a negligible volume due to shrinking after polymerization, resulting in the solid particles making up most of the coating volume. Hence, the coating sorption characteristics correspond closely to the properties of the selected solid particles. On the other hand, the results also showed that PTFE AF 2400 can interact with the active surface of the sorbent, leading to the deactivation of the sorbent particles. Therefore, the extraction performance and permeability coefficients decrease as the size of the penetrant increases, indicating a rigid porous structure. The results of this study can aid in the optimization of SPME devices as they provide reference values that can be used to determine the optimal binder and the sorbent affinity for the targeted compounds. Finally, the present work also provides the broader scientific community with a strategy for investigating the properties of sorbent particle/binder structures and defines the characteristics of a good coating/membrane by analyzing all parameters such as kinetics, thermodynamic equilibria, and morphology.
Collapse
Affiliation(s)
- Khaled Murtada
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Emir Nazdrajić
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| |
Collapse
|
6
|
Eggermont D, Spadafora ND, Aspromonte J, Pellegrino R, Purcaro G. Exploring different high-capacity tools and extraction modes to characterize the aroma of brewed coffee. Anal Bioanal Chem 2023:10.1007/s00216-023-04654-2. [PMID: 37041278 DOI: 10.1007/s00216-023-04654-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 03/07/2023] [Accepted: 03/15/2023] [Indexed: 04/13/2023]
Abstract
In the present work, the potential benefit of using multi-cumulative trapping headspace extraction was explored by comparing the results using solid-phase microextraction (SPME) coated with divinylbenzene/carboxen/polydimethylsiloxane and a probe-like tool coated with polydimethylsiloxane. The efficiency of a single 30-min extraction, already explored in previous work, was compared with that of multiple shorter extractions. We evaluated three different conditions, i.e., three repeated extractions for 10 min each from different sample vials (for both the probe-like tool and SPME) or from the same vial (for SPME) containing brewed coffee. The entire study was performed using comprehensive two-dimensional gas chromatography coupled with mass spectrometry. The two-dimensional plots were aligned and integrated using a tile-sum approach before any statistical analysis. A detailed comparison of all the tested conditions was performed on a set of 25 targeted compounds. Although a single 30-min extraction using the probe-like tool provided a significantly higher compound intensity than SPME single extraction, the use of multiple shorter extractions with SPME showed similar results. However, multiple extractions with the probe-like tool showed a greater increase in the number of extracted compounds. Furthermore, an untargeted cross-sample comparison was performed to evaluate the ability of the two tested tools and the different extraction procedures in differentiating between espresso-brewed coffee samples obtained from capsules made of different packaging materials (i.e., compostable capsules, aluminum capsules, aluminum multilayer pack). The highest explained variance was obtained using the probe-like tool and multiple extractions (91.6% compared to 83.9% of the single extraction); nevertheless, SPME multiple extractions showed similar results with 88.3% of variance explained.
Collapse
Affiliation(s)
- Damien Eggermont
- Gembloux Agro-Bio Tech, University of Liège, Bât. G1 Chimie Des Agro-Biosystèmes, Passage Des Déportés 2, 5030, Gembloux, Belgium
| | - Natasha Damiana Spadafora
- Department of Chemical, Pharmaceutical and Agricultural Sciences, University of Ferrara, 44121, Ferrara, Italy
| | - Juan Aspromonte
- Laboratorio de Investigación Y Desarrollo de Métodos Analíticos, LIDMA, Facultad de Ciencias Exactas (Universidad Nacional de La Plata, CIC-PBA, CONICET), 1900, La Plata, Argentina
| | - Rocío Pellegrino
- Laboratorio de Investigación Y Desarrollo de Métodos Analíticos, LIDMA, Facultad de Ciencias Exactas (Universidad Nacional de La Plata, CIC-PBA, CONICET), 1900, La Plata, Argentina
| | - Giorgia Purcaro
- Gembloux Agro-Bio Tech, University of Liège, Bât. G1 Chimie Des Agro-Biosystèmes, Passage Des Déportés 2, 5030, Gembloux, Belgium.
| |
Collapse
|
7
|
Solid Phase Microextraction—A Promising Tool for Graft Quality Monitoring in Solid Organ Transplantation. SEPARATIONS 2023. [DOI: 10.3390/separations10030153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/26/2023] Open
Abstract
Solid organ transplantation is a life-saving intervention for patients suffering from end-stage organ failure. Although improvements in surgical techniques, standards of care, and immunosuppression have been observed over the last few decades, transplant centers have to face the problem of an insufficient number of organs for transplantation concerning the growing demand. An opportunity to increase the pool of organs intended for transplantation is the more frequent use of organs from extended criteria and the development of analytical methods allowing for a better assessment of the quality of organs to minimize the risk of post-transplant organ injury and rejection. Therefore, solid-phase microextraction (SPME) has been proposed in various studies as an effective tool for determining compounds of significance during graft function assessment or for the chemical profiling of grafts undergoing various preservation protocols. This review summarizes how SPME addresses the analytical challenges associated with different matrices utilized in the peri-transplant period and discusses its potential as a diagnostic tool in future work.
Collapse
|
8
|
Solid-phase microextraction with MIL-53(Al)-polymer monolithic column coupled to pressurized capillary electrochromatography for determination of chlorogenic acid and ferulic acid in sugarcane samples. ANAL SCI 2023; 39:925-933. [PMID: 36811757 DOI: 10.1007/s44211-023-00297-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2022] [Accepted: 02/03/2023] [Indexed: 02/24/2023]
Abstract
In this paper, a polymer monolithic column based on poly (Butyl methacrylate-co-ethylene glycol dimethacrylate) (poly (BMA-co-EDGMA)) doped with MIL-53(Al) metal-organic framework (MOF) was prepared using an in situ polymerization method. The characteristics of MIL-53(Al)-polymer monolithic column were studied through scanning electron microscopy (SEM), Fourier transform infrared spectrometry (FT-IR), energy-dispersive spectroscopy (EDS), X-ray powder diffractometry (XRD), and nitrogen adsorption experiment. Due to its large surface area, the prepared MIL-53(Al)-polymer monolithic column has good permeability and high extraction efficiency. Using MIL-53(Al)-polymer monolithic column for solid-phase microextraction (SPME), coupled to pressurized capillary electrochromatography (pCEC), a method for the determination of trace chlorogenic acid and ferulic acid in sugarcane was established. Under optimized conditions, chlorogenic acid and ferulic acid have a good linear relationship (r ≥ 0.9965) within the concentration range of 50.0-500 µg/mL, the detection limit is 0.017 µg/mL, and the relative standard deviation (RSD) is less than 3.2%. The spike recoveries of chlorogenic acid and ferulic acid were 96.5% and 96.7%, respectively. The results indicate that the method is sensitive, practical, and convenient. It has been successfully applied to the separation and detection of trace organic phenolic compounds in sugarcane samples.
Collapse
|
9
|
Metabolite Variation between Nematode and Bacterial Seed Galls in Comparison to Healthy Seeds of Ryegrass Using Direct Immersion Solid-Phase Microextraction (DI-SPME) Coupled with GC-MS. Molecules 2023; 28:molecules28020828. [PMID: 36677885 PMCID: PMC9864257 DOI: 10.3390/molecules28020828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 01/06/2023] [Accepted: 01/11/2023] [Indexed: 01/18/2023] Open
Abstract
Annual ryegrass toxicity (ARGT) is an often-fatal poisoning of livestock that consume annual ryegrass infected by the bacterium Rathayibacter toxicus. This bacterium is carried into the ryegrass by a nematode, Anguina funesta, and produces toxins within seed galls that develop during the flowering to seed maturity stages of the plant. The actual mechanism of biochemical transformation of healthy seeds to nematode and bacterial gall-infected seeds remains unclear and no clear-cut information is available on what type of volatile organic compounds accumulate in the respective galls. Therefore, to fill this research gap, the present study was designed to analyze the chemical differences among nematode galls (A. funesta), bacterial galls (R. toxicus) and healthy seeds of annual ryegrass (Lolium rigidum) by using direct immersion solid-phase microextraction (DI-SPME) coupled with gas chromatography−mass spectrometry (GC-MS). The method was optimized and validated by testing its linearity, sensitivity, and reproducibility. Fifty-seven compounds were identified from all three sources (nematode galls, bacterial galls and healthy seed), and 48 compounds were found to be present at significantly different (p < 0.05) levels in the three groups. Five volatile organic compounds (hexanedioic acid, bis(2-ethylhexyl) ester), (carbonic acid, but-2-yn-1-yl eicosyl ester), (fumaric acid, 2-ethylhexyl tridec-2-yn-1-yl ester), (oct-3-enoylamide, N-methyl-N-undecyl) and hexacosanoic acid are the most frequent indicators of R. toxicus bacterial infection in ryegrass, whereas the presence of 15-methylnonacosane, 13-methylheptacosane, ethyl hexacosyl ether, heptacosyl acetate and heptacosyl trifluoroacetate indicates A. funesta nematode infestation. Metabolites occurring in both bacterial and nematode galls included batilol (stearyl monoglyceride) and 9-octadecenoic acid (Z)-, tetradecyl ester. Among the chemical functional group, esters, fatty acids, and alcohols together contributed more than 70% in healthy seed, whereas this contribution was 61% and 58% in nematode and bacterial galls, respectively. This study demonstrated that DI-SPME is a valid technique to study differentially expressed metabolites in infected and healthy ryegrass seed and may help provide better understanding of the biochemical interactions between plant and pathogen to aid in management of ARGT.
Collapse
|
10
|
Llambrich M, Brezmes J, Cumeras R. The untargeted urine volatilome for biomedical applications: methodology and volatilome database. Biol Proced Online 2022; 24:20. [PMID: 36456991 PMCID: PMC9714113 DOI: 10.1186/s12575-022-00184-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Accepted: 11/18/2022] [Indexed: 12/03/2022] Open
Abstract
Chemically diverse in compounds, urine can give us an insight into metabolic breakdown products from foods, drinks, drugs, environmental contaminants, endogenous waste metabolites, and bacterial by-products. Hundreds of them are volatile compounds; however, their composition has never been provided in detail, nor has the methodology used for urine volatilome untargeted analysis. Here, we summarize key elements for the untargeted analysis of urine volatilome from a comprehensive compilation of literature, including the latest reports published. Current achievements and limitations on each process step are discussed and compared. 34 studies were found retrieving all information from the urine treatment to the final results obtained. In this report, we provide the first specific urine volatilome database, consisting of 841 compounds from 80 different chemical classes.
Collapse
Affiliation(s)
- Maria Llambrich
- Department of Electrical Electronic Engineering and Automation, Universitat Rovira I Virgili, 43007 Tarragona, Spain
- Department of Nutrition and Metabolism, Metabolomics Interdisciplinary Group, Institut d’Investigació Sanitària Pere Virgili (IISPV), 43204, Reus, Spain
| | - Jesús Brezmes
- Department of Electrical Electronic Engineering and Automation, Universitat Rovira I Virgili, 43007 Tarragona, Spain
- Department of Nutrition and Metabolism, Metabolomics Interdisciplinary Group, Institut d’Investigació Sanitària Pere Virgili (IISPV), 43204, Reus, Spain
| | - Raquel Cumeras
- Department of Electrical Electronic Engineering and Automation, Universitat Rovira I Virgili, 43007 Tarragona, Spain
- Department of Nutrition and Metabolism, Metabolomics Interdisciplinary Group, Institut d’Investigació Sanitària Pere Virgili (IISPV), 43204, Reus, Spain
- Oncology Department, Institut d’Investigació Sanitària Pere Virgili (IISPV), 43204, Reus, Spain
| |
Collapse
|
11
|
Gao Y, Sheng K, Bao T, Wang S. Recent applications of organic molecule-based framework porous materials in solid-phase microextraction for pharmaceutical analysis. J Pharm Biomed Anal 2022; 221:115040. [PMID: 36126613 DOI: 10.1016/j.jpba.2022.115040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 08/10/2022] [Accepted: 09/08/2022] [Indexed: 11/15/2022]
Abstract
Sample preparation is an indispensable part of detection of complex samples in pharmaceutical analysis. Solid-phase microextraction (SPME) has obtained a lot of attention due to its advantages of time saving, less solvent and easily automation. A variety of functional materials are used as sorbents in SPME to carry out selective and high extraction. This review centers around the recent applications of organic molecule-based framework porous materials, such as metal organic frameworks (MOFs) and covalent organic frameworks (COFs), as SPME coating materials mainly focus on pharmaceutical analysis in food, environment, and biological samples. Four representative extraction devices are introduced, including on-fiber SPME, in-tube SPME, thin film SPME, stir bar SPME. The application prospect of other organic porous materials as sorbents for pharmaceutical analysis are also discussed, such as hyper crosslinked polymers (HCPs) and conjugated microporous polymers (CMPs). The progresses and discusses are provided to offer references for further research focusing on application and development of organic molecule-based framework porous materials in the field of SPME.
Collapse
Affiliation(s)
- Yan Gao
- School of Pharmacy, Health Science Center, Xi'an Jiaotong University, Xi'an 710061, China; Shaanxi Engineering Research Center of Cardiovascular Drugs Screening & Analysis, Xi'an 710061, China
| | - Kangjia Sheng
- School of Pharmacy, Health Science Center, Xi'an Jiaotong University, Xi'an 710061, China; Shaanxi Engineering Research Center of Cardiovascular Drugs Screening & Analysis, Xi'an 710061, China
| | - Tao Bao
- School of Pharmacy, Health Science Center, Xi'an Jiaotong University, Xi'an 710061, China; Shaanxi Engineering Research Center of Cardiovascular Drugs Screening & Analysis, Xi'an 710061, China.
| | - Sicen Wang
- School of Pharmacy, Health Science Center, Xi'an Jiaotong University, Xi'an 710061, China; Shaanxi Engineering Research Center of Cardiovascular Drugs Screening & Analysis, Xi'an 710061, China.
| |
Collapse
|
12
|
Zheng B, Chen L, Zheng T, Hou L, Huang X, Li C, Wang X, Fang Q, Chen J, Tang Z, Li Z, Ouyang D. A novel solid phase extraction sample preparation method for sensitively determining doxepin and N-nordoxepin in human plasma and its application in a bioequivalence study in healthy Chinese volunteers. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:2168-2178. [PMID: 35608048 DOI: 10.1039/d2ay00129b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Doxepin, a tricyclic antidepressant (TCA), is widely used in the treatment of depressive disorder and anxiety. There are some liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods that have been reported for detecting doxepin, but inadequacies in recovery and cumbersome sample preparation obstruct the pharmacokinetics study. Therefore, we aimed to develop and validate a rapid sample preparation method based on solid-phase extraction (SPE) for the precise quantification of doxepin and its metabolites. Chromatography separation was performed on a Waters ACQUITY UPLC BEH C18 column (2.1 × 100 mm, 1.7 μm) and a mobile phase consisting of 70% of mobile phase A (0.1% formic acid and 10 mM ammonium formate) and 30% mobile phase B (0.1% formic acid in acetonitrile) at a flow rate of 0.4 mL min-1 in the step gradient elution conditions. The lower limits of quantification for doxepin and N-nordoxepin were 4 pg mL-1 and 2 pg mL-1, respectively. This method was validated with satisfactory results including good precision and accuracy. A rapid, sensitive, and specific LC-MS/MS method was developed and validated for the determination of doxepin in human plasma. This method could be applied for determining doxepin and N-nordoxepin concentrations in plasma that could be useful for bioequivalence study of 3 mg doxepin.
Collapse
Affiliation(s)
- Binjie Zheng
- Department of Clinical Pharmacology, Xiangya Hospital, Central South University, 87 Xiangya Road, Changsha 410008, P. R. China.
- Institute of Clinical Pharmacology, Central South University, Hunan Key Laboratory of Pharmacogenetics, 110 Xiangya Road, Changsha 410078, P. R. China
- Engineering Research Center of Applied Technology of Pharmacogenomics, Ministry of Education, 110 Xiangya Road, Changsha 410078, P. R. China
| | - Lulu Chen
- Hunan Key Laboratory for Bioanalysis of Complex Matrix Samples, Changsha Duxact Biotech Co., Ltd, Changsha, China.
- Hunan Changsha Duxact Clinical Laboratory Co., Ltd, Changsha Duxact Biotech Co., Ltd, Changsha, China
- School of Pharmacy, Xiangnan University, Chenzhou 423000, China
| | - Tiandong Zheng
- Hunan Key Laboratory for Bioanalysis of Complex Matrix Samples, Changsha Duxact Biotech Co., Ltd, Changsha, China.
- Hunan Changsha Duxact Clinical Laboratory Co., Ltd, Changsha Duxact Biotech Co., Ltd, Changsha, China
| | - Liping Hou
- Hunan Key Laboratory for Bioanalysis of Complex Matrix Samples, Changsha Duxact Biotech Co., Ltd, Changsha, China.
| | - Xinyi Huang
- Department of Clinical Pharmacology, Xiangya Hospital, Central South University, 87 Xiangya Road, Changsha 410008, P. R. China.
- Institute of Clinical Pharmacology, Central South University, Hunan Key Laboratory of Pharmacogenetics, 110 Xiangya Road, Changsha 410078, P. R. China
- Engineering Research Center of Applied Technology of Pharmacogenomics, Ministry of Education, 110 Xiangya Road, Changsha 410078, P. R. China
| | - Chao Li
- Hunan Key Laboratory for Bioanalysis of Complex Matrix Samples, Changsha Duxact Biotech Co., Ltd, Changsha, China.
- Hunan Changsha Duxact Clinical Laboratory Co., Ltd, Changsha Duxact Biotech Co., Ltd, Changsha, China
| | - Xintong Wang
- Hunan Key Laboratory for Bioanalysis of Complex Matrix Samples, Changsha Duxact Biotech Co., Ltd, Changsha, China.
- Hunan Changsha Duxact Clinical Laboratory Co., Ltd, Changsha Duxact Biotech Co., Ltd, Changsha, China
| | - Qing Fang
- Hunan Key Laboratory for Bioanalysis of Complex Matrix Samples, Changsha Duxact Biotech Co., Ltd, Changsha, China.
- Hunan Changsha Duxact Clinical Laboratory Co., Ltd, Changsha Duxact Biotech Co., Ltd, Changsha, China
| | - Jie Chen
- Hunan Key Laboratory for Bioanalysis of Complex Matrix Samples, Changsha Duxact Biotech Co., Ltd, Changsha, China.
- Hunan Changsha Duxact Clinical Laboratory Co., Ltd, Changsha Duxact Biotech Co., Ltd, Changsha, China
| | - Zhi Tang
- Hunan Key Laboratory for Bioanalysis of Complex Matrix Samples, Changsha Duxact Biotech Co., Ltd, Changsha, China.
- Hunan Changsha Duxact Clinical Laboratory Co., Ltd, Changsha Duxact Biotech Co., Ltd, Changsha, China
| | - Zhenyu Li
- Department of Geriatric Medicine, Xiangya Hospital, Central South University, Changsha, China.
| | - Dongsheng Ouyang
- Department of Clinical Pharmacology, Xiangya Hospital, Central South University, 87 Xiangya Road, Changsha 410008, P. R. China.
- Institute of Clinical Pharmacology, Central South University, Hunan Key Laboratory of Pharmacogenetics, 110 Xiangya Road, Changsha 410078, P. R. China
- Engineering Research Center of Applied Technology of Pharmacogenomics, Ministry of Education, 110 Xiangya Road, Changsha 410078, P. R. China
- Hunan Key Laboratory for Bioanalysis of Complex Matrix Samples, Changsha Duxact Biotech Co., Ltd, Changsha, China.
| |
Collapse
|
13
|
Green Extraction Techniques as Advanced Sample Preparation Approaches in Biological, Food, and Environmental Matrices: A Review. MOLECULES (BASEL, SWITZERLAND) 2022; 27:molecules27092953. [PMID: 35566315 PMCID: PMC9101692 DOI: 10.3390/molecules27092953] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 04/28/2022] [Accepted: 05/02/2022] [Indexed: 12/13/2022]
Abstract
Green extraction techniques (GreETs) emerged in the last decade as greener and sustainable alternatives to classical sample preparation procedures aiming to improve the selectivity and sensitivity of analytical methods, simultaneously reducing the deleterious side effects of classical extraction techniques (CETs) for both the operator and the environment. The implementation of improved processes that overcome the main constraints of classical methods in terms of efficiency and ability to minimize or eliminate the use and generation of harmful substances will promote more efficient use of energy and resources in close association with the principles supporting the concept of green chemistry. The current review aims to update the state of the art of some cutting-edge GreETs developed and implemented in recent years focusing on the improvement of the main analytical features, practical aspects, and relevant applications in the biological, food, and environmental fields. Approaches to improve and accelerate the extraction efficiency and to lower solvent consumption, including sorbent-based techniques, such as solid-phase microextraction (SPME) and fabric-phase sorbent extraction (FPSE), and solvent-based techniques (μQuEChERS; micro quick, easy, cheap, effective, rugged, and safe), ultrasound-assisted extraction (UAE), and microwave-assisted extraction (MAE), in addition to supercritical fluid extraction (SFE) and pressurized solvent extraction (PSE), are highlighted.
Collapse
|
14
|
Bukenov B, Baimatova N, Kenessov B. Quantification of transformation products of rocket fuel unsymmetrical dimethylhydrazine in air using solid-phase microextraction. J Sep Sci 2021; 45:614-622. [PMID: 34796657 DOI: 10.1002/jssc.202100684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 11/11/2021] [Accepted: 11/12/2021] [Indexed: 11/06/2022]
Abstract
Quantification of unsymmetrical dimethylhydrazine transformation products in ambient air is important for assessing the environmental impact of heavy rocket launches. There are very little data of such analyses, which is mainly caused by the low number of analytes covered by the available analytical methods and their complexity. A simple and cost-efficient method for accurate simultaneous determination of seven unsymmetrical dimethylhydrazine transformation products in air using solid-phase microextraction followed by gas chromatography-mass spectrometry was developed. The method was optimized for air sampling and solid-phase microextraction from 20-mL vials, which allows full automation of analysis. The extraction for 5 min by Carboxen/polydimethylsiloxane fiber from amber vials and desorption for 3 min provided the greatest analytes' responses, lowest relative standard deviations, linear calibration (R2 ≥ 0.99), and limits of detection from 0.12 to 0.5 μg/m3 . Samples with concentrations 500 μg/m3 can be stored at 21 ± 1°C without substantial losses (1-11%) for up to 24 h, while air samples with concentrations 10 and 50 μg/m3 stored for up to 24 h can be used for accurate quantification of only two and four out of seven analytes, respectively. The developed method was successfully tested for the analysis of air above real soil samples contaminated with unsymmetrical dimethylhydrazine rocket fuel.
Collapse
Affiliation(s)
- Bauyrzhan Bukenov
- Center of Physical Chemical Methods of Research and Analysis, Faculty of Chemistry and Chemical Technology, Al-Farabi Kazakh National University, 96a Tole bi street, Almaty, 050012, Kazakhstan
| | - Nassiba Baimatova
- Center of Physical Chemical Methods of Research and Analysis, Faculty of Chemistry and Chemical Technology, Al-Farabi Kazakh National University, 96a Tole bi street, Almaty, 050012, Kazakhstan
| | - Bulat Kenessov
- Center of Physical Chemical Methods of Research and Analysis, Faculty of Chemistry and Chemical Technology, Al-Farabi Kazakh National University, 96a Tole bi street, Almaty, 050012, Kazakhstan
| |
Collapse
|
15
|
Turoňová D, Kujovská Krčmová L, Švec F. Application of microextraction in pipette tips in clinical and forensic toxicology. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116404] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
16
|
Automatic and renewable micro-solid-phase extraction based on bead injection lab-on-valve system for determination of tranexamic acid in urine by UHPLC coupled with tandem mass spectrometry. Anal Bioanal Chem 2021; 414:649-659. [PMID: 34410441 DOI: 10.1007/s00216-021-03606-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 07/23/2021] [Accepted: 08/05/2021] [Indexed: 10/20/2022]
Abstract
An automatic micro-solid-phase extraction (μSPE) method using on-line renewable sorbent beads followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was established for the determination of tranexamic acid (TXA) in urine. The μSPE method was based on the bead injection (BI) concept combined with the mesofluidic lab-on-valve (LOV) platform. All steps of the μSPE-BI-LOV were implemented by computer programming, rendering enhanced precision on time and flow events. Several parameters, including the type of sorbent, volume and composition of the conditioning solution, washing solution, and eluent composition, were evaluated to improve the extraction efficiency. The best results were obtained with a hydrophilic-lipophilic balanced mixed-mode sorbent, decorated with sulfonic acid groups (Oasis MCX), and 99% acetonitrile-water (50:50, v/v)-1% ammonium hydroxide as eluent. Chromatographic separation was performed using a BEH amide column coupled to MS/MS detection in positive ionization mode. Good linearity was achieved (R2 > 0.998) for TXA concentrations in urine ranging from 300 to 3000 ng mL-1, with LOD and LOQ of 30 and 65 ng mL-1, respectively. Dilution integrity was observed for dilution factors up to 20,000 times, providing the extension of the upper limit of quantification to 12 mg mL-1. The method was validated according to international guidelines and successfully applied to urine samples collected during scoliosis surgery of pediatric patients treated with TXA.
Collapse
|
17
|
Aladaghlo Z, Maddah B, Fakhari AR. Fabrication of Co 3O 4 quantum dot incorporated polyacrylamide ethylene glycol dimethacrylate as a new fiber for solid phase microextraction and trace determination of organophosphorus pesticides in environmental water samples. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:3394-3401. [PMID: 34236068 DOI: 10.1039/d1ay00855b] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
In this paper, a novel solid phase microextraction fiber based on Co3O4 quantum dot incorporated polyacrylamide-co-ethylene glycol dimethacrylate followed by corona discharge ion mobility spectrometry is presented for the trace determination of organophosphorus pesticides in environmental water samples. Ion mobility spectrometry is a comparatively inexpensive, well-known, robust, and easy to operate analytical instrument. This combination would provide a low-cost, fast, selective, and sensitive quantitative system for detection of organophosphorus pesticides. In order to obtain the best extraction efficiency, the optimization of parameters affecting this method was carried out. After optimization, a solution pH of 7.0, extraction temperature of 60 °C, adsorption temperature of 260 °C, extraction time of 30 min, stirring speed of 750 rpm, and ionic strength of 10% w/w were obtained. Consequently, the presented method showed low limits of detection (0.3-0.6 ng mL-1), excellent enrichment factors (PF = 221-263), good linearity (R2 > 0.995), and repeatabilities (intra-day: 3.4 to 4.8%) and (inter-day: 4.7 to 6.1%). The reproducibility (RSD% of fiber to fiber) was also investigated by analyzing three as-prepared fibers under the same conditions and was found to be less than 7.6%. Finally, the developed fiber was used for determination of organophosphorus pesticides in the field samples.
Collapse
Affiliation(s)
- Zolfaghar Aladaghlo
- Department of Analytical Chemistry, Faculty of Chemistry, Shahid Beheshti University, Tehran, Iran
| | | | | |
Collapse
|
18
|
Yu C, Zhang Q, Zou Y, Liu R, Zhao J, Bi K, Li D, Li Q. Across-polarity quantification method for broad metabolome coverage based on consecutive nanoconfined liquid phase nanoextraction technology: Application in discovering the plasma potential biomarkers of different types of cancer. Anal Chim Acta 2021; 1167:338577. [DOI: 10.1016/j.aca.2021.338577] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Revised: 04/21/2021] [Accepted: 04/23/2021] [Indexed: 12/28/2022]
|
19
|
Dowlatshah S, Saraji M, Dinari M, Soltani R. A novel nanocomposite based on covalent organic polymer and nanocellulose for thin-film microextraction of imipramine from biological samples. J Sep Sci 2021; 44:2972-2981. [PMID: 34031991 DOI: 10.1002/jssc.202001245] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Revised: 05/19/2021] [Accepted: 05/20/2021] [Indexed: 01/04/2023]
Abstract
A novel covalent organic polymer was prepared using 1,5-diaminonaphthalene as a linker and cyanuric chloride as a node. A thin-film nanocomposite of 1,5-diaminonaphthalene covalent organic polymer and cellulose nanocrystalline was then fabricated via filtering and casting method. The effect of incorporation of various amounts of 1,5-diaminonaphthalene covalent organic polymer and cellulose nanocrystalline was studied to obtain an efficient nanocomposite thin-film with a large number of polar functional groups and high mechanical stability. Field emission scanning electron microscopy, X-ray diffraction, Fourier transform infrared spectrometry, and thermogravimetric analysis techniques were applied for the characterization of physicochemical properties of the prepared materials. Imipramine was determined in the biological samples using thin-film microextraction followed by gas chromatography flame ionization detection. Parameters affecting the extraction efficiency of imipramine were investigated. Under the optimized conditions, the limit of detection was 0.5 ng/mL. Film-to-film reproducibility for three different films fabricated under the same conditions (at three concentration levels) varied between 8.9 and 9.7%. The linear dynamic range covered more than three orders of magnitude (2-5000 ng/mL) with a determination coefficient of 0.9985. The method was successfully applied for preconcentration and determination of imipramine in biological samples with spiking recoveries between 78 and 93%.
Collapse
Affiliation(s)
- Samira Dowlatshah
- Department of Chemistry, Isfahan University of Technology, Isfahan, Iran
| | - Mohammad Saraji
- Department of Chemistry, Isfahan University of Technology, Isfahan, Iran
| | - Mohammad Dinari
- Department of Chemistry, Isfahan University of Technology, Isfahan, Iran
| | - Roozbeh Soltani
- Department of Chemistry, Isfahan University of Technology, Isfahan, Iran
| |
Collapse
|
20
|
Determinations of new psychoactive substances in biological matrices with focus on microextraction techniques: a review of fundamentals and state-of-the-art extraction methods. Forensic Toxicol 2021. [DOI: 10.1007/s11419-021-00582-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
21
|
Bahrami M, Pirmohammadi Z, Bahrami A. A review of new adsorbents for separation of BTEX biomarkers. Biomed Chromatogr 2021; 35:e5131. [PMID: 33788293 DOI: 10.1002/bmc.5131] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Revised: 03/17/2021] [Accepted: 03/26/2021] [Indexed: 01/09/2023]
Abstract
The biomarker analysis of benzene, toluene, ethylbenzene and xylene (BTEXs) in biological samples is the primary technique for evaluating these compounds in occupational and environmental exposures. The BTEX biomarkers are widely used to study the BTEX distribution in the environment and workplaces. Liquid-liquid extraction and solid-phase liquid extraction are among the most commonly used conventional methods to analyze biological indices of BTEXs. New methods have been proposed to analyze BTEX biomarkers using novel adsorbents such as sol-gel composite nanotubes, molecularly imprinted polymers and metal-organic frameworks, which are based on the application of needle trap devices, microextraction by packed sorbent, and solid-phase microextraction techniques. This paper provides an overview of new methods since 2015 regarding applying microextraction methods based on new adsorbents and analyzing BTEX biomarker compounds for occupational and environmental exposures. The results were compared with the liquid-phase microextraction methods recommended for urinary BTEX biomarkers.
Collapse
Affiliation(s)
- Mohammadreza Bahrami
- Department of Health, Safety and Environment, School of Environment, College of Engineering, University of Tehran, Kish, Iran
| | - Zahra Pirmohammadi
- Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Abdulrahman Bahrami
- Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
| |
Collapse
|
22
|
Daryanavard SM, Zolfaghari H, Abdel-Rehim A, Abdel-Rehim M. Recent applications of microextraction sample preparation techniques in biological samples analysis. Biomed Chromatogr 2021; 35:e5105. [PMID: 33660303 DOI: 10.1002/bmc.5105] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 01/26/2021] [Accepted: 02/05/2021] [Indexed: 12/11/2022]
Abstract
Analysis of biological samples is affected by interfering substances with chemical properties similar to those of the target analytes, such as drugs. Biological samples such as whole blood, plasma, serum, urine and saliva must be properly processed for separation, purification, enrichment and chemical modification to meet the requirements of the analytical instruments. This causes the sample preparation stage to be of undeniable importance in the analysis of such samples through methods such as microextraction techniques. The scope of this review will cover a comprehensive summary of available literature data on microextraction techniques playing a key role for analytical purposes, methods of their implementation in common biological samples, and finally, the most recent examples of application of microextraction techniques in preconcentration of analytes from urine, blood and saliva samples. The objectives and merits of each microextration technique are carefully described in detail with respect to the nature of the biological samples. This review presents the most recent and innovative work published on microextraction application in common biological samples, mostly focused on original studies reported from 2017 to date. The main sections of this review comprise an introduction to the microextraction techniques supported by recent application studies involving quantitative and qualitative results and summaries of the most significant, recently published applications of microextracion methods in biological samples. This article considers recent applications of several microextraction techniques in the field of sample preparation for biological samples including urine, blood and saliva, with consideration for extraction techniques, sample preparation and instrumental detection systems.
Collapse
Affiliation(s)
| | - Hesane Zolfaghari
- Department of Chemistry, Faculty of Science, University of Hormozgan, Bandar-Abbas, Iran
| | - Abbi Abdel-Rehim
- Department of Chemical Engineering and Biotechnology, Cambridge University, Cambridge, UK
| | - Mohamed Abdel-Rehim
- Functional Materials Division, Department of Applied Physics, School of Engineering Sciences, KTH Royal Institute of Technology, Stockholm, Sweden.,Department of Clinical Neuroscience, Centre for Psychiatry Research, Karolinska Institutet, Solna, Sweden
| |
Collapse
|
23
|
Abedi H. Solid-phase microextraction of methadone by using a chitosan nanocomposite incorporated with Polyoxomolibdate nanocluster/Graphene oxide. J Sep Sci 2021; 44:1969-1977. [PMID: 33594820 DOI: 10.1002/jssc.202100095] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Accepted: 02/13/2021] [Indexed: 12/19/2022]
Abstract
In the present study, we report on the simple sol-gel preparation of a nanocomposite composed of chitosan/ polyoxometalate /graphene oxide, and its application in the headspace solid-phase microextraction combined with the ion mobility spectrometry for the analysis of methadone in biological matrices. The developed nanocomposite was characterized through the infrared spectroscopy and thermogravimetric analyses. The ternary nanocomposite coating offers good mechanical and thermal stability and high extraction efficiency thanks to its large specific surface. A central composite statistical design was used to study the main variables affecting the extraction efficiency. Afterward, to study the relationship between different input and output variables as well as to identify the optimal operating conditions, response surface methodology was used, whereby a second-order polynomial equation was fit to the experimental data. The optimized extraction conditions were as follows: temperature, 70°C; extraction time, 15 min; and concentration of NaCl, 5%w/v. The detection limit of 0.12 ng/mL was obtained at the optimized extraction conditions, and the calibration plot was linear in the concentration range of 0.30-200 ng/mL. With relatively low limit of detection and good precisions, the proposed method has the potential for the extraction and determination of methadone in biological samples.
Collapse
Affiliation(s)
- Hamid Abedi
- Department of Police Equipment and Technologies, Police Sciences and Social Studies Institute, Tehran, Iran
| |
Collapse
|
24
|
Grecco CF, Souza ID, Queiroz MEC. Novel materials as capillary coatings for in‐tube solid‐phase microextraction for bioanalysis. J Sep Sci 2021; 44:1662-1693. [DOI: 10.1002/jssc.202001070] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 01/11/2021] [Accepted: 01/31/2021] [Indexed: 12/18/2022]
Affiliation(s)
- Caroline Fernandes Grecco
- Faculdade de Filosofia Ciências e Letras de Ribeirão Preto Departamento de Química Universidade de São Paulo São Paulo Brazil
| | - Israel Donizeti Souza
- Faculdade de Filosofia Ciências e Letras de Ribeirão Preto Departamento de Química Universidade de São Paulo São Paulo Brazil
| | - Maria Eugênia Costa Queiroz
- Faculdade de Filosofia Ciências e Letras de Ribeirão Preto Departamento de Química Universidade de São Paulo São Paulo Brazil
| |
Collapse
|
25
|
Sheikh M, Hadjmohammadi MR, Fatemi MH. Simultaneous extraction and analysis of clozapine and lorazepam from human plasma using dual solvent-stir bar microextraction with different acceptor phases followed by high-performance liquid chromatography ultra-violet detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:110-116. [PMID: 33315030 DOI: 10.1039/d0ay01431a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
A new design of dual solvent stir bar microextraction (DSSBME) was developed and combined with HPLC-UV for the simultaneous extraction of clozapine (CLZ) and lorazepam (LRP) from human plasma with different acceptor phases. Two short hollow fibers immobilized with an organic extraction solvent were used as the solvent bars for microextraction of CLZ and LRP from the sample solution. The solvent bars were fixed with a staple pin which served as the stirrer. The target analytes were simultaneously and selectively extracted from the sample solution into their corresponding solvent bar. Extraction parameters such as organic solvent type, pH of the sample solution, the acceptor phase concentration, salt incorporation into the solution, stirring rate, and extraction time were optimized to achieve the best extraction results. Under the optimum conditions (1-undecanol as extraction solvent, pH of sample solution = 9.0, 10% w/v NaCl, concentration of HCl = 10 mM, concentration of NaOH = 100 mM, stirring rate of 1400 rpm and extraction time of 30 min at ambient temperature) the limit of detection for CLZ was 0.4 ng mL-1 and for LRP it was 1.1 ng mL-1. The linear range for CLZ was 1.3-1000.0 ng mL-1 (R2 = 0.9991) and for LRP it was 3.6-800.0 ng mL-1 (R2 = 0.9993). Extraction recovery and the enrichment factor for CLZ were 95.4% and 343 and for LRP they were 74.3% and 263, respectively. Finally, the method developed was successfully applied for the simultaneous determination of CLZ and LRP in human plasma samples.
Collapse
Affiliation(s)
- Mahsa Sheikh
- Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, NirooHavayii Boulevard, 47416-95447 Babolsar, Iran.
| | | | | |
Collapse
|
26
|
Suchatanugal N, Chedthanorrakul P, Thaveesangsakulthai I, Nhujak T, Kulsing C. Thin layer chromatography based extraction approaches for improved analysis of volatile compounds with gas chromatography-mass spectrometry and direct analysis with gas analyzer. J Sep Sci 2020; 44:666-675. [PMID: 33197986 DOI: 10.1002/jssc.202000917] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Revised: 11/08/2020] [Accepted: 11/12/2020] [Indexed: 02/02/2023]
Abstract
In this study, thin-layer chromatography was applied for selective extraction of volatile compounds in perfume prior to analysis with solid phase microextraction and gas chromatography-mass spectrometry. The standard compounds were desorbed from the thin-layer chromatography plate and extracted at 80°C for 15 min showing good linearity of the calibration curves (R2 > 0.98) and acceptable recovery range (65-81%). The plate after the separation was cut into four smaller parts followed by solid phase microextraction/gas chromatography-mass spectrometry analysis, which revealed different compound profile in each part with the correlation between log P of the standard compounds and their positions along the thin-layer chromatography plate (R2 = 0.65). This approach was applied to analyze perfume compounds in the sample with strong matrix interference from the synthetic agarwood. Terpene hydrocarbons (woody-based odors), ketones/esters, aldehydes, ethers, and alcohols were mostly observed at 8 ± 1, 6 ± 1, 5 ± 2, 4 ± 2, and 3 ± 2 cm, respectively, from the bottom of the thin-layer chromatography plate. While, the conventional solid phase microextraction/gas chromatography-mass spectrometry analysis of this sample solution revealed only 62 compounds (including 35 perfume compounds), the four-piece approach resulted in 109 compounds (62 perfume compounds). Furthermore, the capability of thin-layer chromatography-Gas Analyzer approach to analyze the isomers in this complex sample was demonstrated.
Collapse
Affiliation(s)
- Nattapat Suchatanugal
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| | | | | | - Thumnoon Nhujak
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand.,Chromatographic Separation and Flavor Chemistry Research Unit and Center of Molecular Sensory Science, Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Chadin Kulsing
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand.,Chromatographic Separation and Flavor Chemistry Research Unit and Center of Molecular Sensory Science, Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| |
Collapse
|
27
|
Development of continuously operated aqueous two-phase microextraction process using natural deep eutectic solvents. Sep Purif Technol 2020. [DOI: 10.1016/j.seppur.2020.116746] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
28
|
Krčmová LK, Melichar B, Švec F. Chromatographic methods development for clinical practice: requirements and limitations. Clin Chem Lab Med 2020; 58:1785-1793. [DOI: 10.1515/cclm-2020-0517] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Accepted: 05/25/2020] [Indexed: 12/30/2022]
Abstract
Abstract
Development of a chromatographic method in bioanalysis is a challenging and complex procedure with many pitfalls and often unexpected reversals that can require several months to accomplish. Even an experienced analytical team must contend many limitations mainly in connection with the strict requirements imposed on current clinical research. These restrictions typically persist throughout the whole development process, from clinical trial assignment, across optimization of extraction of biological materials and chromatographic separation, to validation and data interpretation. This paper describes questions and their possible answers raised during the pre-analytical phase such as use of modern sample preparation techniques in clinical methods, application of internal standards, as well as selection of stationary phases and detection techniques in the analytical phase. Validation problems and interpretation of results are demonstrated with three typical examples of characteristics to be considered, i.e. recovery, matrix effect, and limit of detection vs. lower limit of quantification.
Collapse
Affiliation(s)
- Lenka Kujovská Krčmová
- The Department of Analytical Chemistry, Faculty of Pharmacy , Charles University , Hradec Králové , Czech Republic
- The Department of Clinical Biochemistry and Diagnostics , University Hospital , Sokolská 581, 500 05 Hradec Králové , Czech Republic
| | - Bohuslav Melichar
- The Department of Oncology, Faculty of Medicine and Dentistry , Palacky University , Olomouc , Olomouc , Czech Republic
| | - František Švec
- The Department of Analytical Chemistry, Faculty of Pharmacy , Charles University , Hradec Králové , Czech Republic
| |
Collapse
|
29
|
Advances in Solid-Phase Microextraction. SEPARATIONS 2020. [DOI: 10.3390/separations7020034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Analysis imposes substantial challenges, especially when dealing with analytes present at trace levels in complex matrices [...]
Collapse
|
30
|
Liu Z, Zhou W, Wang C, Hu W, Chen Z. Cotton thread modified with ionic liquid copolymerized polymer for online in‐tube solid‐phase microextraction and HPLC analysis of nonsteroidal anti‐inflammatory drugs. J Sep Sci 2020; 43:2827-2833. [DOI: 10.1002/jssc.202000212] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 04/12/2020] [Accepted: 04/13/2020] [Indexed: 12/29/2022]
Affiliation(s)
- Zichun Liu
- Key Laboratory of Combinatorial Biosynthesis and Drug DiscoveryMinistry of EducationHubei Province Engineering and Technology Research Center for Fluorinated Pharmaceuticalsand Wuhan University School of Pharmaceutical Sciences Wuhan P. R. China
- State Key Laboratory of Transducer TechnologyChinese Academy of Sciences Beijing P. R. China
| | - Wei Zhou
- Key Laboratory of Combinatorial Biosynthesis and Drug DiscoveryMinistry of EducationHubei Province Engineering and Technology Research Center for Fluorinated Pharmaceuticalsand Wuhan University School of Pharmaceutical Sciences Wuhan P. R. China
- State Key Laboratory of Transducer TechnologyChinese Academy of Sciences Beijing P. R. China
| | - Chenlu Wang
- Key Laboratory of Combinatorial Biosynthesis and Drug DiscoveryMinistry of EducationHubei Province Engineering and Technology Research Center for Fluorinated Pharmaceuticalsand Wuhan University School of Pharmaceutical Sciences Wuhan P. R. China
| | - Wei Hu
- Key Laboratory of Combinatorial Biosynthesis and Drug DiscoveryMinistry of EducationHubei Province Engineering and Technology Research Center for Fluorinated Pharmaceuticalsand Wuhan University School of Pharmaceutical Sciences Wuhan P. R. China
| | - Zilin Chen
- Key Laboratory of Combinatorial Biosynthesis and Drug DiscoveryMinistry of EducationHubei Province Engineering and Technology Research Center for Fluorinated Pharmaceuticalsand Wuhan University School of Pharmaceutical Sciences Wuhan P. R. China
- State Key Laboratory of Transducer TechnologyChinese Academy of Sciences Beijing P. R. China
| |
Collapse
|
31
|
Seidi S, Mohammadi F, Tajik M, Baharfar M, Mohammadi A, Otoufat T. Quantitative determination of trace phenazopyridine in human urine samples by hyphenation of dispersive solid-phase extraction and liquid-phase microextraction followed by gas chromatography/mass spectrometry analysis. J Sep Sci 2020; 43:2897-2904. [PMID: 32396240 DOI: 10.1002/jssc.202000055] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Revised: 04/10/2020] [Accepted: 05/04/2020] [Indexed: 12/13/2022]
Abstract
Magnetic dispersive solid-phase extraction followed by dispersive liquid-liquid microextraction coupled with gas chromatography/mass spectrometry was applied for the quantitative analysis of phenazopyridine in urinary samples. Magnetic dispersive solid-phase extraction was carried out using magnetic graphene oxide nanoparticles modified by poly(thiophene-pyrrole) copolymer. The eluting solvent of this step was used as the disperser solvent for the dispersive liquid-liquid microextraction procedure. To reach the maximum efficiency of the method, effective parameters including sorbent amount, adsorption time, type and volume of disperser and extraction solvents, pH of the sample solution, and ionic strength as well as desorption time, and approach were optimized, separately. Characterization of the synthesized sorbent was studied by utilizing infrared spectroscopy, scanning electron microscopy, and energy-dispersive X-ray analysis. Calibration curve was linear in the range of 0.5-250 ng/mL (R2 = 0.9988) with limits of detection and quantification of 0.1 and 0.5 ng/mL, respectively. Intra- and interday precisions (RSD%, n = 3) of the method were in the range of 4.6-5.4% and 4.0-5.5%, respectively, at three different concentration levels. Under the optimal condition, this method was successfully applied for the determination of phenazopyridine in human urine samples. The relative recoveries were obtained in the range of 85.0-89.0%.
Collapse
Affiliation(s)
- Shahram Seidi
- Department of Analytical Chemistry, Faculty of Chemistry, K. N. Toosi University of Technology, Tehran, Iran
| | - Fahimeh Mohammadi
- Department of Analytical Chemistry, Faculty of Chemistry, K. N. Toosi University of Technology, Tehran, Iran
| | - Mohammad Tajik
- Department of Chemistry, Tarbiat Modares University, Tehran, Iran
| | - Mahroo Baharfar
- Department of Chemistry, Tarbiat Modares University, Tehran, Iran
| | - Abdorreza Mohammadi
- Department of Food Science and Technology, Faculty of Nutrition Science, Food science and Technology/National Nutrition and Food Technology Research Institute, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Tohid Otoufat
- Department of Analytical Chemistry, Faculty of Chemistry, K. N. Toosi University of Technology, Tehran, Iran
| |
Collapse
|
32
|
Manousi N, Tzanavaras PD, Zacharis CK. Bioanalytical HPLC Applications of In-Tube Solid Phase Microextraction: A Two-Decade Overview. Molecules 2020; 25:molecules25092096. [PMID: 32365828 PMCID: PMC7248733 DOI: 10.3390/molecules25092096] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 04/28/2020] [Accepted: 04/29/2020] [Indexed: 12/18/2022] Open
Abstract
In-tube solid phase microextraction is a cutting-edge sample treatment technique offering significant advantages in terms of miniaturization, green character, automation, and preconcentration prior to analysis. During the past years, there has been a considerable increase in the reported publications, as well as in the research groups focusing their activities on this technique. In the present review article, HPLC bioanalytical applications of in-tube SPME are discussed, covering a wide time frame of twenty years of research reports. Instrumental aspects towards the coupling of in-tube SPME and HPLC are also discussed, and detailed information on materials/coatings and applications in biological samples are provided.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Analytical Chemistry, School of Chemistry, Faculty of Sciences, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece; (N.M.); (P.D.T.)
| | - Paraskevas D. Tzanavaras
- Laboratory of Analytical Chemistry, School of Chemistry, Faculty of Sciences, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece; (N.M.); (P.D.T.)
| | - Constantinos K. Zacharis
- Laboratory of Pharmaceutical Analysis, Department of Pharmaceutical Technology, School of Pharmacy, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece
- Correspondence: ; Tel.: +30-231-099-7663
| |
Collapse
|
33
|
Mascrez S, Purcaro G. Exploring multiple‐cumulative trapping solid‐phase microextraction for olive oil aroma profiling. J Sep Sci 2020; 43:1934-1941. [DOI: 10.1002/jssc.202000098] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Revised: 03/03/2020] [Accepted: 03/03/2020] [Indexed: 01/01/2023]
Affiliation(s)
- Steven Mascrez
- Gembloux Agro‐Bio TechUniversity of Liège Gembloux Belgium
| | | |
Collapse
|
34
|
Jalili V, Barkhordari A, Ghiasvand A. Bioanalytical Applications of Microextraction Techniques: A Review of Reviews. Chromatographia 2020. [DOI: 10.1007/s10337-020-03884-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
35
|
Matys J, Gieroba B, Jóźwiak K. Recent developments of bioanalytical methods in determination of neurotransmitters in vivo. J Pharm Biomed Anal 2020; 180:113079. [DOI: 10.1016/j.jpba.2019.113079] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Revised: 12/20/2019] [Accepted: 12/23/2019] [Indexed: 12/24/2022]
|
36
|
Abstract
In vivo solid-phase microextraction (SPME) has been recently proposed for the extraction, clean-up and preconcentration of analytes of biological and clinical concern. Bioanalysis can be performed by sampling exo- or endogenous compounds directly in living organisms with minimum invasiveness. In this context, innovative and miniaturized devices characterized by both commercial and lab-made coatings for in vivo SPME tissue sampling have been proposed, thus assessing the feasibility of this technique for biomarker discovery, metabolomics studies or for evaluating the environmental conditions to which organisms can be exposed. Finally, the possibility of directly interfacing SPME to mass spectrometers represents a valuable tool for the rapid quali- and quantitative analysis of complex matrices. This review article provides a survey of in vivo SPME applications focusing on the extraction of tissues, cells and simple organisms. This survey will attempt to cover the state-of- the-art from 2014 up to 2019.
Collapse
|
37
|
Firoozichahak A, Bahrami A, Ghorbani Shahna F, Alizadeh S, Nematollahi D, Farhadian M. Development of a needle trap device packed with titanium-based metal-organic framework sorbent for extraction of phenolic derivatives in air. J Sep Sci 2019; 43:1011-1018. [PMID: 31854086 DOI: 10.1002/jssc.201900938] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Revised: 12/11/2019] [Accepted: 12/11/2019] [Indexed: 12/15/2022]
Abstract
We developed a novel method of needle trap device packed with titanium-based metal-organic framework for the extraction of phenolic derivatives in air followed by gas chromatography-flame ionization detector analysis. The synthetized adsorbent was packed inside a 22-gauge spinal needle. This method was first tested at laboratory scale, and then was used for field sampling of phenolic derivatives in air. A glass chamber placed on a heater at 60°C was used to provide different concentrations of phenolic derivatives. The desorption conditions and breakthrough volume were optimized using response surface methodology. The limit of detection and limit of quantitation of the proposed method were estimated to be in the range of 0.001-0.12 and 0.003-0.62 ng/mL, respectively, indicating a high sensitivity for the suggested sampler. Storing the packed needle trap device in a refrigerator at 4˚C for 60 days did not dramatically affect the storage stability. Our findings indicated that there was a high correlation coefficient (R2 = 0.99) between the measurement results of this method and the NIOSH recommended method (XAD-7 sorbent tube). Therefore, it can be concluded that the needle trap device packed with titanium-based metal-organic framework can be used as a efficient method for extraction of phenolic derivatives in air.
Collapse
Affiliation(s)
- Ali Firoozichahak
- Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Abdulrahman Bahrami
- Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Farshid Ghorbani Shahna
- Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Saber Alizadeh
- Department of Chemistry, Bu-Ali-Sina University, Hamedan, Iran
| | | | - Maryam Farhadian
- Department of Biostatistics, School of Public Health and Research Center for Health Sciences, Hamadan University of Medical Sciences, Hamadan, Iran
| |
Collapse
|
38
|
Kim S, Yin X, Prodhan MAI, Zhang X, Zhong Z, Kato I. Global Plasma Profiling for Colorectal Cancer-Associated Volatile Organic Compounds: a Proof-of-Principle Study. J Chromatogr Sci 2019; 57:385-396. [PMID: 30796770 DOI: 10.1093/chromsci/bmz011] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2018] [Revised: 12/14/2018] [Accepted: 01/24/2019] [Indexed: 12/12/2022]
Abstract
Volatile organic compounds (VOCs) could reflect changes resulting from ongoing pathophysiological processes and altered body metabolisms, and thus have been studied for various types of cancers. We aimed to test an advanced global metabolomic technique to characterize circulating VOCs in patients diagnosed with colorectal cancer (CRC). We employed solid-phase microextraction (SPME) and comprehensive two-dimensional gas chromatography mass-spectrometry (GC × GC-MS). We analyzed 30 random plasma samples from incident cases of CRC. The 30 samples were from population controls enrolled in a large population-based case-control study. The number of metabolite peaks detected in the cases was significantly lower than that detected in the controls (median 1530 vs. 1694, P = 0.02). Partial least squares-discriminant analysis showed clear VOC profile differences between the CRC and the controls. After adjustment for multiple comparisons at the 5% false discovery rate level, five VOCs were differentially expressed between the cases and the controls. Among these five VOCs, 2,3,4-trimethyl-hexane (decreased) and 2,4-dimethylhept-1-ene (increased) were both lipid peroxidation products but not previously reported for CRC. In summary, this study pointed to an intriguing observation that the richness of volatile metabolites may be reduced in CRC cases and demonstrated the utility of SPME GC × GC-MS in discovery of candidate markers for further validation.
Collapse
Affiliation(s)
- Seongho Kim
- Department of Oncology, Wayne State University School of Medicine, Detroit MI, USA.,Biostatistics Core, Karmanos Cancer Institute, Wayne State University, Detroit MI, USA
| | - Xinmin Yin
- Department of Chemistry, University of Louisville, Louisville, Kentucky, USA
| | | | - Xiang Zhang
- Department of Chemistry, University of Louisville, Louisville, Kentucky, USA
| | - Zichun Zhong
- Department of Computer Science, College of Engineering, Wayne State University, Detroit MI, USA
| | - Ikuko Kato
- Department of Oncology, Wayne State University School of Medicine, Detroit MI, USA.,Department of Pathology, Wayne State University School of Medicine, Detroit MI, USA
| |
Collapse
|
39
|
Luo Z, Chen G, Li X, Wang L, Shu H, Cui X, Chang C, Zeng A, Fu Q. Molecularly imprinted polymer solid‐phase microextraction coupled with ultra high performance liquid chromatography and tandem mass spectrometry for rapid analysis of pyrrolizidine alkaloids in herbal medicine. J Sep Sci 2019; 42:3352-3362. [DOI: 10.1002/jssc.201900665] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2019] [Revised: 08/22/2019] [Accepted: 08/24/2019] [Indexed: 01/20/2023]
Affiliation(s)
- Zhimin Luo
- School of PharmacyXi'an Jiaotong University Xi'an P. R. China
- Key Laboratory of Tibetan Medicine ResearchNorthwest Institute of Plateau Biology, Chinese Academy of Sciences Xining P. R. China
| | - Guoning Chen
- School of PharmacyXi'an Jiaotong University Xi'an P. R. China
| | - Xuan Li
- School of PharmacyXi'an Jiaotong University Xi'an P. R. China
| | - Lu Wang
- School of PharmacyXi'an Jiaotong University Xi'an P. R. China
| | - Hua Shu
- School of PharmacyXi'an Jiaotong University Xi'an P. R. China
| | - Xia Cui
- School of PharmacyXi'an Jiaotong University Xi'an P. R. China
| | - Chun Chang
- School of PharmacyXi'an Jiaotong University Xi'an P. R. China
| | - Aiguo Zeng
- School of PharmacyXi'an Jiaotong University Xi'an P. R. China
| | - Qiang Fu
- School of PharmacyXi'an Jiaotong University Xi'an P. R. China
| |
Collapse
|
40
|
Hasanli F, Bahmaei M, Mohammadiazar S, Sharif AAM. Electroless deposition of silver nanofractals on copper wire by galvanic displacement as a simple technique for preparation of porous solid-phase microextraction fibers. J Sep Sci 2019; 42:3110-3118. [PMID: 31364241 DOI: 10.1002/jssc.201900351] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2019] [Revised: 07/02/2019] [Accepted: 07/20/2019] [Indexed: 01/13/2023]
Abstract
A novel and porous solid-phase microextraction fiber was prepared by quick and simple galvanic displacement reaction and applied to the determination of some polycyclic aromatic hydrocarbons in sunflower oil. The parameters affecting the porosity and thickness of the fiber, and parameters affecting the extraction efficiency, including the extraction time, temperature, and ionic strength, were investigated and optimized. The morphology of prepared fiber was characterized by optical and scanning electron microscopy and thermal and chemical stabilities of the fiber were studied. Under the optimum conditions, the limits of detection ranged between 0.1 ng/mL for pyrene to 1.2 ng/mL for anthracene, and LOQ ranged between 0.3 ng/mL for pyrene to 3.6 ng/mL for anthracene. The relative standard deviations, including repeatability (within fibers) and reproducibility (between fibers), varied between 3.2-8.9 and 5.6-9.8%, respectively.
Collapse
Affiliation(s)
- Fateme Hasanli
- Department of Chemistry, Tehran North Branch, Islamic Azad University, Tehran, Iran
| | - Manochehr Bahmaei
- Department of Chemistry, Tehran North Branch, Islamic Azad University, Tehran, Iran
| | - Sirwan Mohammadiazar
- Environmental Health Research Center, Research Institute for Health Development, Kurdistan University of Medical Sciences, Sanandaj, Iran
| | | |
Collapse
|
41
|
Saurina J, Sentellas S. Liquid chromatography coupled to mass spectrometry for metabolite profiling in the field of drug discovery. Expert Opin Drug Discov 2019; 14:469-483. [DOI: 10.1080/17460441.2019.1582638] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Javier Saurina
- Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, Barcelona, Spain
| | - Sonia Sentellas
- Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, Barcelona, Spain
| |
Collapse
|