Wahabi JM, Wong JHD, Mahdiraji GA, Ung NM. Feasibility of determining external beam radiotherapy dose using LuSy dosimeter. J Appl Clin Med Phys 2024; 25:e14387. [PMID: 38778567 PMCID: PMC11163501 DOI: 10.1002/acm2.14387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 04/20/2024] [Accepted: 04/26/2024] [Indexed: 05/25/2024] Open
Abstract
INTRODUCTION Radiation dose measurement is an essential part of radiotherapy to verify the correct delivery of doses to patients and ensure patient safety. Recent advancements in radiotherapy technology have highlighted the need for fast and precise dosimeters. Technologies like FLASH radiotherapy and magnetic-resonance linear accelerators (MR-LINAC) demand dosimeters that can meet their unique requirements. One promising solution is the plastic scintillator-based dosimeter with high spatial resolution and real-time dose output. This study explores the feasibility of using the LuSy dosimeter, an in-house developed plastic scintillator dosimeter for dose verification across various radiotherapy techniques, including conformal radiotherapy (CRT), intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT), and stereotactic radiosurgery (SRS). MATERIALS AND METHODS A new dosimetry system, comprising a new plastic scintillator as the sensing material, was developed and characterized for radiotherapy beams. Treatment plans were created for conformal radiotherapy, IMRT, VMAT, and SRS and delivered to a phantom. LuSy dosimeter was used to measure the delivered dose for each plan on the surface of the phantom and inside the target volumes. Then, LuSy measurements were compared against an ionization chamber, MOSFET dosimeter, radiochromic films, and dose calculated using the treatment planning system (TPS). RESULTS For CRT, surface dose measurement by LuSy dosimeter showed a deviation of -5.5% and -5.4% for breast and abdomen treatment from the TPS, respectively. When measuring inside the target volume for IMRT, VMAT, and SRS, the LuSy dosimeter produced a mean deviation of -3.0% from the TPS. Surface dose measurement resulted in higher TPS discrepancies where the deviations for IMRT, VMAT, and SRS were -2.0%, -19.5%, and 16.1%, respectively. CONCLUSION The LuSy dosimeter was feasible for measuring radiotherapy doses for various treatment techniques. Treatment delivery verification enables early error detection, allowing for safe treatment delivery for radiotherapy patients.
Collapse
Affiliation(s)
- Janatul Madinah Wahabi
- Department of Biomedical ImagingFaculty of MedicineUniversiti MalayaKuala LumpurMalaysia
- Radiotherapy and Oncology DepartmentNational Cancer InstitutePutrajayaMalaysia
| | - Jeannie Hsiu Ding Wong
- Department of Biomedical ImagingFaculty of MedicineUniversiti MalayaKuala LumpurMalaysia
- Universiti Malaya Research Imaging Centre (UMRIC), Faculty of MedicineUniversiti MalayaKuala LumpurMalaysia
| | | | - Ngie Min Ung
- Clinical Oncology UnitFaculty of MedicineUniversiti MalayaKuala LumpurMalaysia
| |
Collapse
|
2
|
Ferrer C, Huertas C, García D, Sáez M. Dosimetric characterization of a novel commercial plastic scintillation detector with an MR-Linac. Med Phys 2023; 50:2525-2539. [PMID: 36611266 DOI: 10.1002/mp.16204] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2022] [Revised: 12/15/2022] [Accepted: 12/19/2022] [Indexed: 01/09/2023] Open
Abstract
BACKGROUND Plastic scintillators have been used as radiation detectors for the past few years, as they are water-equivalent and independent of the dose, dose rate, and angle of incidence. In addition, they are also independent of the presence of a magnetic field and could be used for in vivo dosimetry in an MR-Linac. With the advent of a new commercial scintillation detector, Blue Physics Model 10, its characterization has been performed on an MR-Linac with a view to future applications. PURPOSE To perform the dosimetric characterization and study potential applications of a novel commercial plastic scintillation detector in a MR-Linac. METHODS Scintillation detector description, calibration procedure, short-term repeatability, dose-response linearity, dose-rate dependence, angular dependence, and temperature dependence have been studied. Percent-depth-dose (PDD) and beam profiles were measured for small fields and a standard field, as well as output factors, for comparison with other PTW detectors: a diamond diode and PinPoint and Semiflex 3D ionization chambers. The suitability of the plastic scintillator for in vivo dosimetry in a magnetic field has also been studied measuring the dose to a point in an anthropomorphic phantom while acquiring MR imaging. This measured dose was compared with that calculated with Monaco planning system and with that measured with a PTW Semiflex 3D chamber, the latter without acquiring MR images. RESULTS Short-term repeatability presented negligible variations (<0.4%) for 100 and 20 MU. Similar results were obtained for dose-response linearity and dose-rate dependence. A small angular dependence was determined, while the scintillator resulted practically independent of the temperature. PDDs showed excellent agreement except in the build-up region, and calculated penumbras with the profiles given by the scintillator were between the ones obtained with the diamond detector and the PinPoint ionization chamber. Measured OF with the scintillator were the highest between all detectors, 1.26% higher than the value obtained with the microdiamond for the smallest field measured, 0.5 × 0.5 cm2 . Finally, the total dose to a point measured with the scintillator was 0.51% higher compared to that calculated by the planning system. CONCLUSION The Blue Physics model 10 scintillation system showed excellent dosimetric characteristics. Its response independent of the temperature and the presence of a magnetic field make it suitable for in vivo dosimetry in an MR-Linac while acquiring MR images, which could solve the impossibility of performing a dosimetric QA for each adapted plan. Furthermore, its temporal resolution allows independent radiation pulses to be measured and visualized, which could be used in future applications.
Collapse
Affiliation(s)
- Carlos Ferrer
- Medical Physics and Radiation Protection Department, La Paz University Hospital, Madrid, Spain
| | - Concepción Huertas
- Medical Physics and Radiation Protection Department, La Paz University Hospital, Madrid, Spain
| | - David García
- Medical Physics and Radiation Protection Department, La Paz University Hospital, Madrid, Spain
| | - Moisés Sáez
- Medical Physics and Radiation Protection Department, La Paz University Hospital, Madrid, Spain
| |
Collapse
|
3
|
Jacqmin DJ, Miller JR, Barraclough BA, Labby ZE. Commissioning an Exradin W2 plastic scintillation detector for clinical use in small radiation fields. J Appl Clin Med Phys 2022; 23:e13728. [PMID: 35861648 PMCID: PMC9359019 DOI: 10.1002/acm2.13728] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Accepted: 06/29/2022] [Indexed: 12/02/2022] Open
Abstract
Purpose The purpose of this work is to evaluate the Standard Imaging Exradin W2 plastic scintillation detector (W2) for use in the types of fields used for stereotactic radiosurgery. Methods Prior to testing the W2 in small fields, the W2 was evaluated in standard large field conditions to ensure good detector performance. These tests included energy dependence, short‐term repeatability, dose‐response linearity, angular dependence, temperature dependence, and dose rate dependence. Next, scan settings and calibration of the W2 were optimized to ensure high quality data acquisition. Profiles of small fields shaped by cones and multi‐leaf collimator (MLCs) were measured using the W2 and IBA RAZOR diode in a scanning water tank. Output factors for cones (4–17.5 mm) and MLC fields (1, 2, 3 cm) were acquired with both detectors. Finally, the dose at isocenter for seven radiosurgery plans was measured with the W2 detector. Results W2 exhibited acceptable warm‐up behavior, short‐term reproducibility, axial angular dependence, dose‐rate linearity, and dose linearity. The detector exhibits a dependence upon energy, polar angle, and temperature. Scanning measurements taken with the W2 and RAZOR were in good agreement, with full‐width half‐maximum and penumbra widths agreeing to within 0.1 mm. The output factors measured by the W2 and RAZOR exhibited a maximum difference of 1.8%. For the seven point‐dose measurements of radiosurgery plans, the W2 agreed well with our treatment planning system with a maximum deviation of 2.2%. The Čerenkov light ratio calibration method did not significantly impact the measurement of relative profiles, output factors, or point dose measurements. Conclusion The W2 demonstrated dosimetric characteristics that are suitable for radiosurgery field measurements. The detector agreed well with the RAZOR diode for output factors and scanned profiles and showed good agreement with the treatment planning system in measurements of clinical treatment plans.
Collapse
Affiliation(s)
- Dustin J Jacqmin
- Department of Human Oncology, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Jessica R Miller
- Department of Human Oncology, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Brendan A Barraclough
- Department of Human Oncology, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina, USA
| | - Zacariah E Labby
- Department of Human Oncology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| |
Collapse
|
4
|
Simiele E, Viscariello N, DeWerd L. Monte Carlo modeling of the influence of strong magnetic fields on the stem-effect in plastic scintillation detectors used in radiotherapy dosimetry. Med Phys 2021; 48:1381-1394. [PMID: 33283279 DOI: 10.1002/mp.14637] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 10/03/2020] [Accepted: 11/23/2020] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To investigate the impact of strong magnetic fields on the stem-effect in plastic scintillation detectors (PSDs) using Monte Carlo methods. METHODS Prior to building the light guide model, the properties of the Čerenkov process in GEANT4 were investigated by simulating depth-dose and depth-Čerenkov emission profiles in water as functions of Čerenkov process input parameters. In addition, profile simulations were performed for magnetic field strengths ranging from 0 T to 1.5 T. A PMMA light guide was constructed in GEANT4 using data from the manufacturer and literature. Simulations were performed with the model as functions of depth and fiber-beam angle where the simulated stem-effect spectrum and the Čerenkov light ratio (CLR) were scored and compared to measured data in the literature. The light guide optical properties were iteratively adjusted until agreement between the simulated and measured data was achieved. Simulations were performed with the validated model as functions of depth and magnetic field strength and the simulated data were compared to measured data in the literature. The model was also used to evaluate the sensitivity of the CLR to the various optical properties of the light guide in different irradiation conditions. RESULTS No significant changes in the depth-dose or depth-Čerenkov emission profiles were observed with step-size restrictions imposed by the Čerenkov process input parameters, which was attributed to the condensed history algorithm and transport parameters used in this work. Similar changes in the depth-dose and depth-Čerenkov emission profiles were observed with increasing magnetic field strength, which indicates the Čerenkov process is not adversely impacted by the presence of the magnetic field. Following optimization of the light guide optical properties, agreement within two standard deviations was observed between the simulated and measured optical data for all validation geometries considered. Agreement within one standard deviation was observed between the simulated and measured data for all depths and field strengths ≥0 T whereas discrepancies were observed for magnetic field strengths <-0.35 T. These significant differences were attributed to insufficient measurement data for this irradiation configuration during model validation. Of the light guide optical properties investigated, the fluorescence signal had the greatest impact on the CLR sensitivity to the magnetic field. CONCLUSIONS No significant change in the Čerenkov emission per dose in water was observed for magnetic field strengths up to 1.5 T. The nominal fiber fluorescence signal was found to have a significant impact on the CLR sensitivity to varying irradiation conditions where changes up to 11.7% were observed whereas the mirror reflectivity and fiber attenuation had a modest impact with maximum CLR changes of 2.6% and 1.2% relative to 0 T, respectively. The results of this work suggest light guides with low fiber fluorescence should be used with PSDs for dosimetry measurements in magnetic fields to minimize the impact of the magnetic field on the CLR correction.
Collapse
Affiliation(s)
- E Simiele
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI, 53705, USA
| | - N Viscariello
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI, 53705, USA
| | - L DeWerd
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI, 53705, USA
| |
Collapse
|
5
|
Kim TJ, Cheng K, Zhang H, Liu S, Skinner L, Xing L. Second window near-infrared dosimeter (NIR2D) system for radiation dosimetry. Phys Med Biol 2020; 65:175013. [PMID: 32869751 DOI: 10.1088/1361-6560/ab9b56] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Fiber-coupled scintillation dosimeters are a cost-effective alternative to the conventional ion chambers in radiation dosimetry. However, stem effects from optical fibers such as Cerenkov radiation incur significant errors in the readout signal. Here we introduce a second near-infrared window dosimeter, dubbed as NIR2D, that can potentially be used as real-time radiation detector for clinical megavoltage beams. Lanthanide-based rare-earth NaYF4 nano-phosphors doped with both erbium and cerium elements were synthesized, and a compact 3D printed reader device integrated with a photodetector and data acquisition system was designed. The performance of the NIR2D was tested using a pre-clinical orthovoltage radiation source and a clinical megavoltage radiation source. The system was tested for dose linearity (100, 200, 600 MU), dose rate dependency (100, 200, 400, 600 MU min-1), and energy dependency (6, 10, 15 MV). Test results with the clinical linear accelerator demonstrated excellent dose linearity and dose rate independency when exposed to 6 MV linac beams-both data follows a linear trendline with R2 > 0.99. On the other hand, the NIR2D was energy dependent, where the readout dropped by 9% between 6 and 15 MV. For stem effects, we observed a finite Cerenkov contribution of 1%-3% when exposed between 100-600 MU min-1 (6 MV) and 3%-6% when exposed between 5-15 MV (600 MU min-1). While the stem effects were still observable, we expect that enhancing the current optical setup will simultaneously improve the scintillation signal and reduce the stem effects.
Collapse
Affiliation(s)
- Tae Jin Kim
- Department of Radiation Oncology, Stanford University, Stanford, CA 94305, United States of America. These authors contributed equally to this work
| | | | | | | | | | | |
Collapse
|
6
|
Yada R, Maenaka K, Miyamoto S, Okada G, Sasakura A, Ashida M, Adachi M, Sato T, Wang T, Akasaka H, Mukumoto N, Shimizu Y, Sasaki R. Real-time in vivo dosimetry system based on an optical fiber-coupled microsized photostimulable phosphor for stereotactic body radiation therapy. Med Phys 2020; 47:5235-5249. [PMID: 32654194 DOI: 10.1002/mp.14383] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2020] [Revised: 06/21/2020] [Accepted: 06/30/2020] [Indexed: 12/11/2022] Open
Abstract
PURPOSE To develop an in vivo dosimeter system for stereotactic body radiation therapy (SBRT) that can perform accurate and precise real-time measurements, using a microsized amount of a photostimulable phosphor (PSP), BaFBr:Eu2+ . METHODS The sensitive volume of the PSP was 1.26 × 10-5 cm3 . The dosimeter system was designed to apply photostimulation to the PSP after the decay of noise signals, in synchronization with the photon beam pulse of a linear accelerator (LINAC), to eliminate the noise signals completely using a time separation technique. The noise signals included stem signals, and radioluminescence signals generated by the PSP. In addition, the dosimeter system was built on a storage-type dosimeter that could read out a signal after an arbitrary preset number of photon beam pulses were incident. First, the noise and photostimulated luminescence (PSL) signal decay times were measured. Subsequently, we confirmed that the PSL signals could be exclusively read out within the photon beam pulse interval. Finally, using a water phantom, the basic characteristics of the dosimeter system were demonstrated under SBRT conditions, and the feasibility for clinical application was investigated. The reproducibility, dose linearity, dose-rate dependence, temperature dependence, and angular dependence were evaluated. The feasibility was confirmed by measurements at various dose gradients and using a representative treatment plan for a metastatic liver tumor. A clinical plan was created with a two-arc beam volumetric modulated arc therapy using a 10 MV flattening filter-free photon beam. For the water phantom measurements, the clinical plan was compiled into a plan with a fixed gantry angle of 0°. To evaluate the energy dependence during SBRT, the percent depth dose (PDD) was measured and compared with those calculated via Monte Carlo (MC) simulations. RESULTS All the PSL signals could be read out while eliminating the noise signals within the minimum pulse interval of the LINAC. Stable real-time measurements could be performed with a time resolution of 56 ms (i.e., number of pulses = 20). The dose linearity was good in the dose range of 0.01-100 Gy. The measurements agreed within 1% at dose rates of 40-2400 cGy/min. The temperature and angular dependence were also acceptable since these dependencies had only a negligible effect on the measurements in SBRT. At a dose gradient of 2.21 Gy/mm, the measured dose agreed with that calculated using a treatment planning system (TPS) within the measurement uncertainties due to the probe position. For measurements using a representative treatment plan, the measured dose agreed with that calculated using the TPS within 0.5% at the center of the beam axis. The PDD measurements agreed with the MC calculations to within 1% for field sizes <5 × 5 cm2 . CONCLUSION The in vivo dosimeter system developed using BaFBr:Eu2+ is capable of real-time, accurate, and precise measurement under SBRT conditions. The probe is smaller than a conventional dosimeter, has excellent spatial resolution, and can be valuable in SBRT with a steep dose distribution over a small field. The developed PSP dosimeter system appears to be suitable for in vivo SBRT dosimetry.
Collapse
Affiliation(s)
- Ryuichi Yada
- Division of Radiation Oncology, Kobe University Graduate School of Medicine, 7-5-2 Kusunokicho, Chuouku, Kobe, Hyogo, 650-0017, Japan
| | - Kazusuke Maenaka
- Department of Electrical Engineering and Computer Science, Graduate School of Engineering, University of Hyogo, 2167 Shosha, Himeji, Hyogo, 671-2280, Japan
| | - Shuji Miyamoto
- Laboratory of Advanced Science and Technology for Industry, University of Hyogo, 3-1-2 Kouto, Kamigoricho, Akogun, Hyogo, 678-1205, Japan
| | - Go Okada
- Co-creative Research Center of Industrial Science and Technology, Kanazawa Institute of Technology, 3-1 Yatsukaho, Hakusan, Ishikawa, 924-0838, Japan
| | - Aki Sasakura
- Meisyo Kiko Co., Ltd, 148 Numa, Hikamicho, Tamba, Hyogo, 669-3634, Japan
| | - Motoi Ashida
- Meisyo Kiko Co., Ltd, 148 Numa, Hikamicho, Tamba, Hyogo, 669-3634, Japan
| | - Masashi Adachi
- Meisyo Kiko Co., Ltd, 148 Numa, Hikamicho, Tamba, Hyogo, 669-3634, Japan
| | - Tatsuhiko Sato
- Nuclear Science and Engineering Center, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai, Ibaraki, 319-1195, Japan
| | - Tianyuan Wang
- Division of Radiation Oncology, Kobe University Graduate School of Medicine, 7-5-2 Kusunokicho, Chuouku, Kobe, Hyogo, 650-0017, Japan
| | - Hiroaki Akasaka
- Division of Radiation Oncology, Kobe University Graduate School of Medicine, 7-5-2 Kusunokicho, Chuouku, Kobe, Hyogo, 650-0017, Japan
| | - Naritoshi Mukumoto
- Division of Radiation Oncology, Kobe University Graduate School of Medicine, 7-5-2 Kusunokicho, Chuouku, Kobe, Hyogo, 650-0017, Japan
| | - Yasuyuki Shimizu
- Division of Radiation Oncology, Kobe University Graduate School of Medicine, 7-5-2 Kusunokicho, Chuouku, Kobe, Hyogo, 650-0017, Japan
| | - Ryohei Sasaki
- Division of Radiation Oncology, Kobe University Graduate School of Medicine, 7-5-2 Kusunokicho, Chuouku, Kobe, Hyogo, 650-0017, Japan
| |
Collapse
|
7
|
Simiele E, Kapsch RP, Ankerhold U, Culberson W, DeWerd L. Technical note: characterization of spectral changes with measurement geometry and magnetic field strength in light guides used for scintillation dosimetry. ACTA ACUST UNITED AC 2020; 65:11NT01. [DOI: 10.1088/1361-6560/ab8afa] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|