Cho H, Lee JS, Kim JS, Kim D, Chang JS, Byun HK, Lee IJ, Kim YB, Kim C, Lee H, Kim H. Generating 3D images of VMAT plans for predictive models and activation maps associated with plan deliverability. Med Phys 2024. [PMID: 38978162 DOI: 10.1002/mp.17298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Revised: 05/20/2024] [Accepted: 06/28/2024] [Indexed: 07/10/2024] Open
Abstract
BACKGROUND Intensity modulation with dynamic multi-leaf collimator (MLC) and monitor unit (MU) changes across control points (CPs) characterizes volumetric modulated arc therapy (VMAT). The increased uncertainty in plan deliverability required patient-specific quality assurance (PSQA), which remained inefficient upon Quality Assurance (QA) failure. To prevent waste before QA, plan complexity metrics (PCMs) and machine learning models with the metrics were generated, which were lack of providing CP-specific information upon QA failures. PURPOSE By generating 3D images from digital imaging and comminications in medicine in radiation therapy (DICOM RT) plan, we proposed a predictive model that can estimate the deliverability of VMAT plans and visualize CP-specific regions associated with plan deliverability. METHODS The patient cohort consisted of 259 and 190 cases for left- and right-breast VMAT treatments, which were split into 235 and 166 cases for training and 24 cases from each treatment for testing the networks. Three-channel 3D images generated from DICOM RT plans were fed into a DenseNet-based deep learning network. To reflect VMAT plan complexity as an image, the first two channels described MLC and MU variations between two consecutive CPs, while the last channel assigned the beam field size. The network output was defined as binary classified PSQA results, indicating deliverability. The predictive performance was assessed by accuracy, sensitivity, specificity, F1-score, and area under the curve (AUC). The gradient-weighted class activation map (Grad-CAM) highlighted the regions of CPs in VMAT plans associated with deliverability, compared against PCMs by Spearman correlation. RESULTS The DenseNet-based predictive model yielded AUCs of 92.2% and 93.8%, F1-scores of 97.0% and 93.8% and accuracies of 95.8% and 91.7% for the left- and right-breast VMAT cases. Additionally, the specificity of 87.5% for both cases indicated that the predictive model accurately detected QA failing cases. The activation maps significantly differentiated QA failing-labeled from passing-labeled classes for the non-deliverable cases. The PCM with the highest correlation to the Grad-CAM varied from patient cases, implying that plan deliverability would be considered patient-specific. CONCLUSION This work demonstrated that the deep learning-based network based on visualization of dynamic VMAT plan information successfully predicted plan deliverability, which also provided control-point specific planning parameter information associated with plan deliverability in a patient-specific manner.
Collapse
Affiliation(s)
- Hyeonjeong Cho
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
- Department of Biomedical Sciences, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Jae Sung Lee
- Department of Biomedical Sciences, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Jin Sung Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Deok Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Jee Suk Chang
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Hwa Kyung Byun
- Department of Radiation Oncology, Yongin Severance Hospital, Yonsei University College of Medicine, Gyonggi-do, Republic of Korea
| | - Ik Jae Lee
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Yong Bae Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Changhwan Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Ho Lee
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Hojin Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
2
|
Tozuka R, Kadoya N, Arai K, Sato K, Jingu K. Assessment of the deep learning-based gamma passing rate prediction system for 1.5 T magnetic resonance-guided linear accelerator. Radiol Phys Technol 2024; 17:451-457. [PMID: 38687457 DOI: 10.1007/s12194-024-00800-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 03/29/2024] [Accepted: 03/30/2024] [Indexed: 05/02/2024]
Abstract
Measurement-based verification is impossible for the patient-specific quality assurance (QA) of online adaptive magnetic resonance imaging-guided radiotherapy (oMRgRT) because the patient remains on the couch throughout the session. We assessed a deep learning (DL) system for oMRgRT to predict the gamma passing rate (GPR). This study collected 125 verification plans [reference plan (RP), 100; adapted plan (AP), 25] from patients with prostate cancer treated using Elekta Unity. Based on our previous study, we employed a convolutional neural network that predicted the GPRs of nine pairs of gamma criteria from 1%/1 mm to 3%/3 mm. First, we trained and tested the DL model using RPs (n = 75 and n = 25 for training and testing, respectively) for its optimization. Second, we tested the GPR prediction accuracy using APs to determine whether the DL model could be applied to APs. The mean absolute error (MAE) and correlation coefficient (r) of the RPs were 1.22 ± 0.27% and 0.29 ± 0.10 in 3%/2 mm, 1.35 ± 0.16% and 0.37 ± 0.15 in 2%/2 mm, and 3.62 ± 0.55% and 0.32 ± 0.14 in 1%/1 mm, respectively. The MAE and r of the APs were 1.13 ± 0.33% and 0.35 ± 0.22 in 3%/2 mm, 1.68 ± 0.47% and 0.30 ± 0.11 in 2%/2 mm, and 5.08 ± 0.29% and 0.15 ± 0.10 in 1%/1 mm, respectively. The time cost was within 3 s for the prediction. The results suggest the DL-based model has the potential for rapid GPR prediction in Elekta Unity.
Collapse
Affiliation(s)
- Ryota Tozuka
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| | - Noriyuki Kadoya
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan.
| | - Kazuhiro Arai
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| | - Kiyokazu Sato
- Department of Radiation Technology, Tohoku University Hospital, Sendai, Japan
| | - Keiichi Jingu
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| |
Collapse
|
3
|
Huang Y, Cai R, Pi Y, Ma K, Kong Q, Zhuo W, Kong Y. A feasibility study to predict 3D dose delivery accuracy for IMRT using DenseNet with log files. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2024:XST230412. [PMID: 38701130 DOI: 10.3233/xst-230412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2024]
Abstract
OBJECTIVE This study aims to explore the feasibility of DenseNet in the establishment of a three-dimensional (3D) gamma prediction model of IMRT based on the actual parameters recorded in the log files during delivery. METHODS A total of 55 IMRT plans (including 367 fields) were randomly selected. The gamma analysis was performed using gamma criteria of 3% /3 mm (Dose Difference/Distance to Agreement), 3% /2 mm, 2% /3 mm, and 2% /2 mm with a 10% dose threshold. In addition, the log files that recorded the gantry angle, monitor units (MU), multi-leaf collimator (MLC), and jaws position during delivery were collected. These log files were then converted to MU-weighted fluence maps as the input of DenseNet, gamma passing rates (GPRs) under four different gamma criteria as the output, and mean square errors (MSEs) as the loss function of this model. RESULTS Under different gamma criteria, the accuracy of a 3D GPR prediction model decreased with the implementation of stricter gamma criteria. In the test set, the mean absolute error (MAE) of the prediction model under the gamma criteria of 3% /3 mm, 2% /3 mm, 3% /2 mm, and 2% /2 mm was 1.41, 1.44, 3.29, and 3.54, respectively; the root mean square error (RMSE) was 1.91, 1.85, 4.27, and 4.40, respectively; the Sr was 0.487, 0.554, 0.573, and 0.506, respectively. There was a correlation between predicted and measured GPRs (P < 0.01). Additionally, there was no significant difference in the accuracy between the validation set and the test set. The accuracy in the high GPR group was high, and the MAE in the high GPR group was smaller than that in the low GPR group under four different gamma criteria. CONCLUSIONS In this study, a 3D GPR prediction model of patient-specific QA using DenseNet was established based on log files. As an auxiliary tool for 3D dose verification in IMRT, this model is expected to improve the accuracy and efficiency of dose validation.
Collapse
Affiliation(s)
- Ying Huang
- Institute of Modern Physics, Fudan University, Shanghai, China
- Institute of Radiation Medicine, Fudan University, Shanghai, China
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Ruxin Cai
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Yifei Pi
- Department of Radiation Oncology, The First Affiliated Hospital of Zhengzhou University, Henan, China
| | - Kui Ma
- Varian Medical Systems No. 8 Yun Cheng Street, Beijing, China
| | - Qing Kong
- Institute of Modern Physics, Fudan University, Shanghai, China
| | - Weihai Zhuo
- Institute of Radiation Medicine, Fudan University, Shanghai, China
| | - Yan Kong
- Department of Radiation Oncology, Affiliated Hospital of Jiangnan University, Jiangsu, China
| |
Collapse
|
4
|
Desai V, Labby Z, Culberson W, DeWerd L, Kry S. Multi-institution single geometry plan complexity characteristics based on IROC phantoms. Med Phys 2024. [PMID: 38669453 DOI: 10.1002/mp.17086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 03/12/2024] [Accepted: 03/27/2024] [Indexed: 04/28/2024] Open
Abstract
BACKGROUND Clinical intensity modulated radiation therapy plans have been described using various complexity metrics to help identify problematic radiotherapy plans. Most previous studies related to the quantification of plan complexity and their utility have relied on institution-specific plans which can be highly variable depending on the machines, planning techniques, delivery modalities, and measurement devices used. In this work, 1723 plans treating one of only four standardized geometries were simultaneously analyzed to investigate how radiation plan complexity metrics vary across four different sets of common objectives. PURPOSE To assess the treatment plan complexity characteristics of plans developed for Imaging and Radiation Oncology Core (IROC) phantoms. Specifically, to understand the variability in plan complexity between institutions for a common plan objective, and to evaluate how various complexity metrics differentiate relevant groups of plans. METHODS 1723 plans treating one of four standardized IROC phantom geometries representing four different anatomical sites of treatment were analyzed. For each plan, 22 MLC-descriptive plan complexity metrics were calculated, and principal component analysis (PCA) was applied to the 22 metrics in order to evaluate differences in plan complexity between groups. Across all metrics, pairwise comparisons of the IROC phantom data were made for the following classifications of the data: anatomical phantom treated, treatment planning system (TPS), and the combination of MLC model and treatment planning system. An objective k-means clustering algorithm was also applied to the data to determine if any meaningful distinctions could be made between different subgroups. The IROC phantom database was also compared to a clinical database from the University of Wisconsin-Madison (UW) which included plans treating the same four anatomical sites as the IROC phantoms using a TrueBeam™ STx and Pinnacle3 TPS. RESULTS The IROC head and neck and spine plans were distinct from the prostate and lung plans based on comparison of the 22 metrics. All IROC phantom plan group complexity metric distributions were highly variable despite all plans being designed for identical geometries and plan objectives. The clusters determined by the k-means algorithm further supported that the IROC head and neck and spine plans involved similar amounts of complexity and were largely distinct from the prostate and lung plans, but no further distinctions could be made. Plan complexity in the head and neck and spine IROC phantom plans were similar to the complexity encountered in the UW clinical plans. CONCLUSIONS There is substantial variability in plan complexity between institutions when planning for the same objective. For each IROC anatomical phantom treated, the magnitude of variability in plan complexity between institutions is similar to the variability in plan complexity encountered within a single institution database containing several hundred unique clinical plans treating corresponding anatomies in actual patients.
Collapse
Affiliation(s)
- Vimal Desai
- Department of Radiation Oncology, Sidney Kimmel Medical College, Thomas Jefferson University, Hospitals, Philadelphia, Pennsylvania, USA
| | - Zacariah Labby
- Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Wesley Culberson
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Larry DeWerd
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Stephen Kry
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center Houston, Houston, Texas, USA
| |
Collapse
|
5
|
Xie L, Zhang L, Hu T, Li G, Yi Z. Neural Network Model Based on Branch Architecture for the Quality Assurance of Volumetric Modulated Arc Therapy. Bioengineering (Basel) 2024; 11:362. [PMID: 38671783 PMCID: PMC11048630 DOI: 10.3390/bioengineering11040362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 04/06/2024] [Accepted: 04/09/2024] [Indexed: 04/28/2024] Open
Abstract
Radiation therapy relies on quality assurance (QA) to verify dose delivery accuracy. However, current QA methods suffer from operation lag as well as inaccurate performance. Hence, to address these shortcomings, this paper proposes a QA neural network model based on branch architecture, which is based on the analysis of the category features of the QA complexity metrics. The designed branch network focuses on category features, which effectively improves the feature extraction capability for complexity metrics. The branch features extracted by the model are fused to predict the GPR for more accurate QA. The performance of the proposed method was validated on the collected dataset. The experiments show that the prediction performance of the model outperforms other QA methods; the average prediction errors for the test set are 2.12% (2%/2 mm), 1.69% (3%/2 mm), and 1.30% (3%/3 mm). Moreover, the results indicate that two-thirds of the validation samples' model predictions perform better than the clinical evaluation results, suggesting that the proposed model can assist physicists in the clinic.
Collapse
Affiliation(s)
- Lizhang Xie
- Machine Intelligence Laboratory, College of Computer Science, Sichuan University, Chengdu 610065, China (Z.Y.)
| | - Lei Zhang
- Machine Intelligence Laboratory, College of Computer Science, Sichuan University, Chengdu 610065, China (Z.Y.)
| | - Ting Hu
- Machine Intelligence Laboratory, College of Computer Science, Sichuan University, Chengdu 610065, China (Z.Y.)
| | - Guangjun Li
- Cancer Center and State Key Laboratory of Biotherapy, Department of Radiation Oncology, West China Hospital, Sichuan University, Chengdu 610041, China
| | - Zhang Yi
- Machine Intelligence Laboratory, College of Computer Science, Sichuan University, Chengdu 610065, China (Z.Y.)
| |
Collapse
|
6
|
Shan G, Yu S, Lai Z, Xuan Z, Zhang J, Wang B, Ge Y. A Review of Artificial Intelligence Application for Radiotherapy. Dose Response 2024; 22:15593258241263687. [PMID: 38912333 PMCID: PMC11193352 DOI: 10.1177/15593258241263687] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Accepted: 05/03/2024] [Indexed: 06/25/2024] Open
Abstract
Background and Purpose Artificial intelligence (AI) is a technique which tries to think like humans and mimic human behaviors. It has been considered as an alternative in a lot of human-dependent steps in radiotherapy (RT), since the human participation is a principal uncertainty source in RT. The aim of this work is to provide a systematic summary of the current literature on AI application for RT, and to clarify its role for RT practice in terms of clinical views. Materials and Methods A systematic literature search of PubMed and Google Scholar was performed to identify original articles involving the AI applications in RT from the inception to 2022. Studies were included if they reported original data and explored the clinical applications of AI in RT. Results The selected studies were categorized into three aspects of RT: organ and lesion segmentation, treatment planning and quality assurance. For each aspect, this review discussed how these AI tools could be involved in the RT protocol. Conclusions Our study revealed that AI was a potential alternative for the human-dependent steps in the complex process of RT.
Collapse
Affiliation(s)
- Guoping Shan
- School of Electronic Science and Engineering, Nanjing University, Nanjing, China
- Zhejiang Cancer Hospital, Hangzhou, China
| | - Shunfei Yu
- Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou, China
| | - Zhongjun Lai
- Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou, China
| | - Zhiqiang Xuan
- Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou, China
| | - Jie Zhang
- Zhejiang Cancer Hospital, Hangzhou, China
| | | | - Yun Ge
- School of Electronic Science and Engineering, Nanjing University, Nanjing, China
| |
Collapse
|
7
|
Wen X, Zhao C, Zhao B, Yuan M, Chang J, Liu W, Meng J, Shi L, Yang S, Zeng J, Yang Y. Application of deep learning in radiation therapy for cancer. Cancer Radiother 2024; 28:208-217. [PMID: 38519291 DOI: 10.1016/j.canrad.2023.07.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Revised: 07/17/2023] [Accepted: 07/18/2023] [Indexed: 03/24/2024]
Abstract
In recent years, with the development of artificial intelligence, deep learning has been gradually applied to clinical treatment and research. It has also found its way into the applications in radiotherapy, a crucial method for cancer treatment. This study summarizes the commonly used and latest deep learning algorithms (including transformer, and diffusion models), introduces the workflow of different radiotherapy, and illustrates the application of different algorithms in different radiotherapy modules, as well as the defects and challenges of deep learning in the field of radiotherapy, so as to provide some help for the development of automatic radiotherapy for cancer.
Collapse
Affiliation(s)
- X Wen
- Cancer Institute of the Affiliated Hospital of Qingdao University and Qingdao Cancer Institute, Qingdao University, Qingdao, China; Department of Radiotherapy, Yunnan Cancer Hospital, the Third Affiliated Hospital of Kunming Medical University, Kunming, Yunnan, China
| | - C Zhao
- School of Biomedical Engineering, Shanghai Jiao Tong University, No. 800, Dongchuan Road, Minhang District, Shanghai, China
| | - B Zhao
- Department of Radiotherapy, Yunnan Cancer Hospital, the Third Affiliated Hospital of Kunming Medical University, Kunming, Yunnan, China
| | - M Yuan
- Department of Radiotherapy, Yunnan Cancer Hospital, the Third Affiliated Hospital of Kunming Medical University, Kunming, Yunnan, China
| | - J Chang
- Cancer Institute of the Affiliated Hospital of Qingdao University and Qingdao Cancer Institute, Qingdao University, Qingdao, China; School of Basic Medicine, Qingdao University, Qingdao, China
| | - W Liu
- Cancer Institute of the Affiliated Hospital of Qingdao University and Qingdao Cancer Institute, Qingdao University, Qingdao, China; School of Basic Medicine, Qingdao University, Qingdao, China
| | - J Meng
- Cancer Institute of the Affiliated Hospital of Qingdao University and Qingdao Cancer Institute, Qingdao University, Qingdao, China; School of Basic Medicine, Qingdao University, Qingdao, China
| | - L Shi
- Cancer Institute of the Affiliated Hospital of Qingdao University and Qingdao Cancer Institute, Qingdao University, Qingdao, China; School of Basic Medicine, Qingdao University, Qingdao, China
| | - S Yang
- Cancer Institute of the Affiliated Hospital of Qingdao University and Qingdao Cancer Institute, Qingdao University, Qingdao, China; School of Basic Medicine, Qingdao University, Qingdao, China
| | - J Zeng
- Cancer Institute of the Affiliated Hospital of Qingdao University and Qingdao Cancer Institute, Qingdao University, Qingdao, China; School of Basic Medicine, Qingdao University, Qingdao, China
| | - Y Yang
- Department of Radiotherapy, Yunnan Cancer Hospital, the Third Affiliated Hospital of Kunming Medical University, Kunming, Yunnan, China.
| |
Collapse
|
8
|
Okamoto H, Wakita A, Tani K, Kito S, Kurooka M, Kodama T, Tohyama N, Fujita Y, Nakamura S, Iijima K, Chiba T, Nakayama H, Murata M, Goka T, Igaki H. Plan complexity metrics for head and neck VMAT competition plans. Med Dosim 2024:S0958-3947(24)00009-8. [PMID: 38368182 DOI: 10.1016/j.meddos.2024.01.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 12/22/2023] [Accepted: 01/24/2024] [Indexed: 02/19/2024]
Abstract
Previous plan competitions have largely focused on dose metric assessments. However, whether the submitted plans were realistic and reasonable from a quality assurance (QA) perspective remains unclear. This study aimed to investigate the relationship between aperture-based plan complexity metrics (PCM) in volumetric modulated arc therapy (VMAT) competition plans and clinical treatment plans verified through patient-specific QA (PSQA). In addition, the association of PCMs with plan quality was examined. A head and neck (HN) plan competition was held for Japanese institutions from June 2019 to July 2019, in which 210 competition plans were submitted. Dose distribution quality was quantified based on dose-volume histogram (DVH) metrics by calculating the dose distribution plan score (DDPS). Differences in PCMs between the two VMAT treatment plan groups (HN plan competitions held in Japan and clinically accepted HN VMAT plans through PSQA) were investigated. The mean (± standard deviation) DDPS for the 98 HN competition plans was 158.5 ± 20.6 (maximum DDPS: 200). DDPS showed a weak correlation with PCMs with a maximum r of 0.45 for monitor unit (MU); its correlation with some PCMs was "very weak." Significant differences were found in some PCMs between plans with the highest 20% DDPSs and the remaining plans. The clinical VMAT and competition plans revealed similar distributions for some PCMs. Deviations in PCMs for the two groups were comparable, indicating considerable variability among planners regarding planning skills. The plan complexity for HN VMAT competition plans increased for high-quality plans, as shown by the dose distribution. Direct comparison of PCMs between competition plans and clinically accepted plans showed that the submitted HN VMAT competition plans were realistic and reasonable from the QA perspective. This evaluation may provide a set of criteria for evaluating plan quality in plan competitions.
Collapse
Affiliation(s)
- Hiroyuki Okamoto
- Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan.
| | - Akihisa Wakita
- Division of Medical Physics, EuroMediTech Co., LTD., 2-20-4 higashigotanda, shinagawa-ku Tokyo, 141-0022, Japan
| | - Kensuke Tani
- Division of Medical Physics, EuroMediTech Co., LTD., 2-20-4 higashigotanda, shinagawa-ku Tokyo, 141-0022, Japan
| | - Satoshi Kito
- Department of Radiology, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital, 3-18-22 Honkomagome, Bunkyo-ku Tokyo,113-8677, Japan
| | - Masahiko Kurooka
- Department of Radiation Therapy, Tokyo Medical University Hospital, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo 160-0023, Japan
| | - Takumi Kodama
- Department of Radiation Oncology, Saitama Cancer Center, 780 Ooazakomuro, Inamachi, Kitaadachi-gun Saitama 362-0806, Japan
| | - Naoki Tohyama
- Division of Medical Physics, Tokyo Bay Makuhari Clinic for Advanced Imaging, Cancer Screening, and High-Precision Radiotherapy, 1-17 Toyosuna, Mihama-ku Chiba, Chiba, 261-0024, Japan
| | - Yukio Fujita
- Department of Radiation Sciences, Komazawa University, 1-23-1, komazawa, setagaya-ku Tokyo, 154-8525, Japan
| | - Satoshi Nakamura
- Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan
| | - Kotaro Iijima
- Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan
| | - Takahito Chiba
- Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan
| | - Hiroki Nakayama
- Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan
| | - Miyuki Murata
- Department of Radiological Technology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan
| | - Tomonori Goka
- Department of Radiological Technology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan
| | - Hiroshi Igaki
- Department of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan
| |
Collapse
|
9
|
Tan HQ, Lew KS, Wong YM, Chong WC, Koh CWY, Chua CGA, Yeap PL, Ang KW, Lee JCL, Park SY. Detecting outliers beyond tolerance limits derived from statistical process control in patient-specific quality assurance. J Appl Clin Med Phys 2024; 25:e14154. [PMID: 37683120 PMCID: PMC10860546 DOI: 10.1002/acm2.14154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 08/18/2023] [Accepted: 08/21/2023] [Indexed: 09/10/2023] Open
Abstract
BACKGROUND Tolerance limit is defined on pre-treatment patient specific quality assurance results to identify "out of the norm" dose discrepancy in plan. An out-of-tolerance plan during measurement can often cause treatment delays especially if replanning is required. In this study, we aim to develop an outlier detection model to identify out-of-tolerance plan early during treatment planning phase to mitigate the above-mentioned risks. METHODS Patient-specific quality assurance results with portal dosimetry for stereotactic body radiotherapy measured between January 2020 and December 2021 were used in this study. Data were divided into thorax and pelvis sites and gamma passing rates were recorded using 2%/2 mm, 2%/1 mm, and 1%/1 mm gamma criteria. Statistical process control method was used to determine six different site and criterion-specific tolerance and action limits. Using only the inliers identified with our determined tolerance limits, we trained three different outlier detection models using the plan complexity metrics extracted from each treatment field-robust covariance, isolation forest, and one class support vector machine. The hyperparameters were optimized using the F1-score calculated from both the inliers and validation outliers' data. RESULTS 308 pelvis and 200 thorax fields were used in this study. The tolerance (action) limits for 2%/2 mm, 2%/1 mm, and 1%/1 mm gamma criteria in the pelvis site are 99.1% (98.1%), 95.8% (91.1%), and 91.7% (86.1%), respectively. The tolerance (action) limits in the thorax site are 99.0% (98.7%), 97.0% (96.2%), and 91.5% (87.2%). One class support vector machine performs the best among all the algorithms. The best performing model in the thorax (pelvis) site achieves a precision of 0.56 (0.54), recall of 1.0 (1.0), and F1-score of 0.72 (0.70) when using the 2%/2 mm (2%/1 mm) criterion. CONCLUSION The model will help the planner to identify an out-of-tolerance plan early so that they can refine the plan further during the planning stage without risking late discovery during measurement.
Collapse
Affiliation(s)
- Hong Qi Tan
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
- Oncology Academic Clinical ProgrammeDuke‐NUS Medical SchoolSingaporeSingapore
| | - Kah Seng Lew
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
- Division of Physics and Applied PhysicsNanyang Technological UniversitySingaporeSingapore
| | - Yun Ming Wong
- Division of Physics and Applied PhysicsNanyang Technological UniversitySingaporeSingapore
| | - Wen Chuan Chong
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
| | - Calvin Wei Yang Koh
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
| | | | - Ping Lin Yeap
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
| | - Khong Wei Ang
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
| | - James Cheow Lei Lee
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
- Division of Physics and Applied PhysicsNanyang Technological UniversitySingaporeSingapore
| | - Sung Yong Park
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
- Oncology Academic Clinical ProgrammeDuke‐NUS Medical SchoolSingaporeSingapore
| |
Collapse
|
10
|
Ocampo J, Heyes G, Dehghani H, Scanlon T, Jolly S, Gibson A. Determination of output factor for CyberKnife using scintillation dosimetry and deep learning. Phys Med Biol 2024; 69:025024. [PMID: 38181420 DOI: 10.1088/1361-6560/ad1b69] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Accepted: 01/05/2024] [Indexed: 01/07/2024]
Abstract
Objective. Small-field dosimetry is an ongoing challenge in radiotherapy quality assurance (QA) especially for radiosurgery systems such as CyberKnifeTM. The objective of this work is to demonstrate the use of a plastic scintillator imaged with a commercial camera to measure the output factor of a CyberKnife system. The output factor describes the dose on the central axis as a function of collimator size, and is a fundamental part of CyberKnife QA and integral to the data used in the treatment planning system.Approach. A self-contained device consisting of a solid plastic scintillator and a camera was build in a portable Pelicase. Photographs were analysed using classical methods and with convolutional neural networks (CNN) to predict beam parameters which were then compared to measurements.Main results. Initial results using classical image processing to determine standard QA parameters such as percentage depth dose (PDD) were unsuccessful, with 34% of points failing to meet the Gamma criterion (which measures the distance between corresponding points and the relative difference in dose) of 2 mm/2%. However, when images were processed using a CNN trained on simulated data and a green scintillator sheet, 92% of PDD curves agreed with measurements with a microdiamond detector to within 2 mm/2% and 78% to 1%/1 mm. The mean difference between the output factors measured using this system and a microdiamond detector was 1.1%. Confidence in the results was enhanced by using the algorithm to predict the known collimator sizes from the photographs which it was able to do with an accuracy of less than 1 mm.Significance. With refinement, a full output factor curve could be measured in less than an hour, offering a new approach for rapid, convenient small-field dosimetry.
Collapse
Affiliation(s)
- Jeremy Ocampo
- UCL Physics and Astronomy, London, WC1E 6BT, United Kingdom
| | - Geoff Heyes
- Radiotherapy Physics, University Hospitals Birmingham NHS Foundation Trust, Birmingham B15 2TH, United Kingdom
| | - Hamid Dehghani
- School of Computer Science, University of Birmingham, Birmingham B15 2TT, United Kingdom
| | - Tim Scanlon
- UCL Physics and Astronomy, London, WC1E 6BT, United Kingdom
| | - Simon Jolly
- UCL Physics and Astronomy, London, WC1E 6BT, United Kingdom
| | - Adam Gibson
- UCL Medical Physics & Biomedical Engineering, London, WC1E 6BT, United Kingdom
| |
Collapse
|
11
|
Koganezawa AS, Matsuura T, Kawahara D, Nakashima T, Shiba E, Murakami Y, Nagata Y. Unbiased evaluation of predicted gamma passing rate by an event-mixing technique. Med Phys 2024; 51:5-17. [PMID: 38009570 DOI: 10.1002/mp.16848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 10/31/2023] [Accepted: 10/31/2023] [Indexed: 11/29/2023] Open
Abstract
BACKGROUND Predicting models of the gamma passing rate (GPR) have been studied to substitute the measurement-based gamma analysis. Since these studies used data from different radiotherapy systems comprising TPS, linear accelerator, and detector array, it has been difficult to compare the performances of the predicting models among institutions with different radiotherapy systems. PURPOSE We aimed to develop unbiased scoring methods to evaluate the performance of the models predicting the GPR, by introducing both best and worst limits for the performance of the GPR prediction. METHODS Two hundred head-and-neck VMAT plans were used to develop a framework. The GPRs were measured using the ArcCHECK device. The predicted GPR [p] was generated using a deep learning-based model [pDL ]. The predicting model was evaluated using four metrics: standard deviation (SD) [σ], Pearson's correlation coefficient (CC) [r], mean squared error (MSE) [s], and mean absolute error (MAE) [a]. The best limit [σ m ${\sigma _m}$ ,r m ${r_m}$ ,s m ${s_m}$ , anda m ${a_m}$ ] was estimated by measuring the SD of measured GPR [m] by shifting the device along the longitudinal direction to measure different sampling points. Mimicked best and worst p's [pbest and pworst ] were generated from pDL . The worst limit was defined such that m and p have no correlation [CC ∼ 0]. The worst limit [σMix , rMix , sMix , and aMix ] was generated using the event-mixing (EM) technique originally introduced in high-energy physics experiments. The range of σ, r, s, and a was defined to be[ σ m , σ Mix ] $[ {{\sigma _m},{\sigma _{{\mathrm{Mix}}}}} ]$ ,[ 0 , r m ] $[ {0,{r_m}} ]$ ,[ s m , s Mix ] $[ {{s_m},{s_{{\mathrm{Mix}}}}} ]$ , and[ a m , a Mix ] $[ {{a_m},{a_{{\mathrm{Mix}}}}} ]$ . The achievement score (AS) independently based on σ, r, s, and a were calculated for pDL , pbest and pworst . The probability that p fails the gamma analysis (alert frequency; AF) was estimated as a function ofσ d ${\sigma _d}$ values within the [σ m ${\sigma _m}$ , σMix ] range for the 3%/2 mm data with a 95% criterion. RESULTS SDs of the best limit were well reproduced byσ m = 0.531 100 - m ${\sigma _m} = \;0.531\sqrt {100 - m} $ . The EM technique successfully generated the( m , p ) $( {m,p} )$ pairs with no correlation. The AS using four metrics showed good agreement. This agreement indicates successful definitions of both best and worst limits, consistent definitions of the AS, and successful generations of mixed events. The AF for the DL-based model with the 3%/2 mm tolerance was 31.5% and 63.0% with CL's 99% and 99.9%, respectively. CONCLUSION We developed the AS to evaluate the predicting model of the GPR in an unbiased manner by excluding the effects of the precision of the radiotherapy system and the spreading of the GPR. The best and worst limits of the GPR prediction were successfully generated using the measured precision of the GPR and the EM technique, respectively. The AS andσ p ${\sigma _p}$ are expected to enable objective evaluation of the predicting model and setting exact achievement goal of precision for the predicted GPR.
Collapse
Affiliation(s)
- Akito S Koganezawa
- Department of Radiation Oncology, Hiroshima University Hospital, Hiroshima, Japan
- Department of Information and Electronic Engineering, Faculty of Science and Engineering, Teikyo University, Tochigi, Japan
| | - Takaaki Matsuura
- Hiroshima High-Precision Radiotherapy Cancer Center, Hiroshima, Japan
- Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Daisuke Kawahara
- Department of Radiation Oncology, Hiroshima University Hospital, Hiroshima, Japan
| | - Takeo Nakashima
- Department of Clinical Support, Radiation Therapy Section, Hiroshima University Hospital, Hiroshima, Japan
| | - Eiji Shiba
- Department of Radiation Oncology, Hospital of the University of Occupational and Environmental Health, Fukuoka, Japan
| | - Yuji Murakami
- Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Yasushi Nagata
- Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
12
|
Sun W, Mo Z, Li Y, Xiao J, Jia L, Huang S, Liao C, Du J, He S, Chen L, Zhang W, Yang X. Machine learning-based ensemble prediction model for the gamma passing rate of VMAT-SBRT plan. Phys Med 2024; 117:103204. [PMID: 38154373 DOI: 10.1016/j.ejmp.2023.103204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 10/29/2023] [Accepted: 12/21/2023] [Indexed: 12/30/2023] Open
Abstract
PURPOSE The purpose of this study was to accurately predict or classify the beam GPR with an ensemble model by using machine learning for SBRT(VMAT) plans. METHODS A total of 128 SBRT VMAT plans with 330 arc beams were retrospectively selected, and 216 radiomics and 34 plan complexity features were calculated for each arc beam. Three models for GPR prediction and classification using support vector machine algorithm were as follows: (1) plan complexity feature-based model (plan model); (2) radiomics feature-based model (radiomics model); and (3) an ensemble model combining the two models (ensemble model). The prediction performance was evaluated by calculating the mean absolute error (MAE), root mean square error (RMSE), and Spearman's correlation coefficient (SC), and the classification performance was measured by calculating the area under the receiver operating characteristic curve (AUC), accuracy, specificity, and sensitivity. RESULTS The MAE, RMSE and SC at the 2 %/2 mm gamma criterion in the test dataset were 1.4 %, 2.57 %, and 0.563, respectively, for the plan model; 1.42 %, and 2.51 %, and 0.508, respectively, for the radiomics model; and 1.33 %, 2.49 %, and 0.611, respectively, for the ensemble model. The accuracy, specificity, sensitivity, and AUC at the 2 %/2 mm gamma criterion in the test dataset were 0.807, 0.824, 0.681, and 0.854, respectively, for the plan model; 0.860, 0.893, 0.624, and 0.877, respectively, for the radiomics model; and 0.852, 0.871, 0.710, and 0.896, respectively, for the ensemble model. CONCLUSIONS The ensemble model can improve the prediction and classification performance for the GPR of SBRT (VMAT).
Collapse
Affiliation(s)
- Wenzhao Sun
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China; Guangdong Esophageal Cancer Institute, Guangzhou, China.
| | - Zijie Mo
- Shenzhen United Imaging Research Institute of Innovative Medical Equipment, Shenzhen, China
| | - Yongbao Li
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Jifeng Xiao
- Shenzhen United Imaging Research Institute of Innovative Medical Equipment, Shenzhen, China
| | - Lecheng Jia
- Shenzhen United Imaging Research Institute of Innovative Medical Equipment, Shenzhen, China
| | - Sijuan Huang
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Can Liao
- Shanghai United Imaging Healthcare Co., Ltd., Shanghai, China
| | - Jinlong Du
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Shumeng He
- United Imaging Research Institute of Intelligent Imaging, Beijing, China
| | - Li Chen
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Wei Zhang
- Shanghai United Imaging Healthcare Co., Ltd., Shanghai, China
| | - Xin Yang
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| |
Collapse
|
13
|
Ishizaka N, Kinoshita T, Sakai M, Tanabe S, Nakano H, Tanabe S, Nakamura S, Mayumi K, Akamatsu S, Nishikata T, Takizawa T, Yamada T, Sakai H, Kaidu M, Sasamoto R, Ishikawa H, Utsunomiya S. Prediction of patient-specific quality assurance for volumetric modulated arc therapy using radiomics-based machine learning with dose distribution. J Appl Clin Med Phys 2024; 25:e14215. [PMID: 37987544 PMCID: PMC10795425 DOI: 10.1002/acm2.14215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 09/29/2023] [Accepted: 10/30/2023] [Indexed: 11/22/2023] Open
Abstract
PURPOSE We sought to develop machine learning models to predict the results of patient-specific quality assurance (QA) for volumetric modulated arc therapy (VMAT), which were represented by several dose-evaluation metrics-including the gamma passing rates (GPRs)-and criteria based on the radiomic features of 3D dose distribution in a phantom. METHODS A total of 4,250 radiomic features of 3D dose distribution in a cylindrical dummy phantom for 140 arcs from 106 clinical VMAT plans were extracted. We obtained the following dose-evaluation metrics: GPRs with global and local normalization, the dose difference (DD) in 1% and 2% passing rates (DD1% and DD2%) for 10% and 50% dose threshold, and the distance-to-agreement in 1-mm and 2-mm passing rates (DTA1 mm and DTA2 mm) for 0.5%/mm and 1.0%.mm dose gradient threshold determined by measurement using a diode array in patient-specific QA. The machine learning regression models for predicting the values of the dose-evaluation metrics using the radiomic features were developed based on the elastic net (EN) and extra trees (ET) models. The feature selection and tuning of hyperparameters were performed with nested cross-validation in which four-fold cross-validation is used within the inner loop, and the performance of each model was evaluated in terms of the root mean square error (RMSE), the mean absolute error (MAE), and Spearman's rank correlation coefficient. RESULTS The RMSE and MAE for the developed machine learning models ranged from <1% to nearly <10% depending on the dose-evaluation metric, the criteria, and dose and dose gradient thresholds used for both machine learning models. It was advantageous to focus on high dose region for predicating global GPR, DDs, and DTAs. For certain metrics and criteria, it was possible to create models applicable for patients' heterogeneity by training only with dose distributions in phantom. CONCLUSIONS The developed machine learning models showed high performance for predicting dose-evaluation metrics especially for high dose region depending on the metric and criteria. Our results demonstrate that the radiomic features of dose distribution can be considered good indicators of the plan complexity and useful in predicting measured dose evaluation metrics.
Collapse
Affiliation(s)
- Natsuki Ishizaka
- Department of RadiologyNiigata Prefectural Shibata HospitalShibata CityNiigataJapan
| | - Tomotaka Kinoshita
- Department of Radiological TechnologyNiigata University Graduate School of Health SciencesNiigata CityNiigataJapan
| | - Madoka Sakai
- Department of RadiologyNagaoka Chuo General HospitalNagaokaNiigataJapan
- Department of Radiation OncologyNiigata University Medical and Dental HospitalNiigata CityNiigataJapan
| | - Shunpei Tanabe
- Department of Radiation OncologyNiigata University Medical and Dental HospitalNiigata CityNiigataJapan
| | - Hisashi Nakano
- Department of Radiation OncologyNiigata University Medical and Dental HospitalNiigata CityNiigataJapan
| | - Satoshi Tanabe
- Department of Radiation OncologyNiigata University Medical and Dental HospitalNiigata CityNiigataJapan
| | - Sae Nakamura
- Department of Radiation OncologyNiigata Neurosurgical HospitalNiigata CityNiigataJapan
| | - Kazuki Mayumi
- Department of Radiological TechnologyNiigata University Graduate School of Health SciencesNiigata CityNiigataJapan
| | - Shinya Akamatsu
- Department of Radiological TechnologyNiigata University Graduate School of Health SciencesNiigata CityNiigataJapan
- Department of RadiologyTakeda General HospitalAizuwakamatsu CityFukushimaJapan
| | - Takayuki Nishikata
- Department of Radiological TechnologyNiigata University Graduate School of Health SciencesNiigata CityNiigataJapan
- Division of RadiologyNagaoka Red Cross HospitalNagaoka‐shiNiigataJapan
| | - Takeshi Takizawa
- Department of Radiation OncologyNiigata University Medical and Dental HospitalNiigata CityNiigataJapan
- Department of Radiation OncologyNiigata Neurosurgical HospitalNiigata CityNiigataJapan
| | - Takumi Yamada
- Section of Radiology, Department of Clinical SupportNiigata University Medical and Dental HospitalNiigata CityNiigataJapan
| | - Hironori Sakai
- Section of Radiology, Department of Clinical SupportNiigata University Medical and Dental HospitalNiigata CityNiigataJapan
| | - Motoki Kaidu
- Department of Radiology and Radiation OncologyNiigata University Graduate School of Medical and Dental SciencesNiigata CityNiigataJapan
| | - Ryuta Sasamoto
- Department of Radiological TechnologyNiigata University Graduate School of Health SciencesNiigata CityNiigataJapan
| | - Hiroyuki Ishikawa
- Department of Radiology and Radiation OncologyNiigata University Graduate School of Medical and Dental SciencesNiigata CityNiigataJapan
| | - Satoru Utsunomiya
- Department of Radiological TechnologyNiigata University Graduate School of Health SciencesNiigata CityNiigataJapan
| |
Collapse
|
14
|
Yoganathan SA, Ahmed S, Paloor S, Torfeh T, Aouadi S, Al-Hammadi N, Hammoud R. Virtual pretreatment patient-specific quality assurance of volumetric modulated arc therapy using deep learning. Med Phys 2023; 50:7891-7903. [PMID: 37379068 DOI: 10.1002/mp.16567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 05/16/2023] [Accepted: 06/02/2023] [Indexed: 06/29/2023] Open
Abstract
BACKGROUND Automatic patient-specific quality assurance (PSQA) is recently explored using artificial intelligence approaches, and several studies reported the development of machine learning models for predicting the gamma pass rate (GPR) index only. PURPOSE To develop a novel deep learning approach using a generative adversarial network (GAN) to predict the synthetic measured fluence. METHODS AND MATERIALS A novel training method called "dual training," which involves the training of the encoder and decoder separately, was proposed and evaluated for cycle GAN (cycle-GAN) and conditional GAN (c-GAN). A total of 164 VMAT treatment plans, including 344 arcs (training data: 262, validation data: 30, and testing data: 52) from various treatment sites, were selected for prediction model development. For each patient, portal-dose-image-prediction fluence from TPS was used as input, and measured fluence from EPID was used as output/response for model training. Predicted GPR was derived by comparing the TPS fluence with the synthetic measured fluence generated by the DL models using gamma evaluation of criteria 2%/2 mm. The performance of dual training was compared against the traditional single-training approach. In addition, we also developed a separate classification model specifically designed to detect automatically three types of errors (rotational, translational, and MU-scale) in the synthetic EPID-measured fluence. RESULTS Overall, the dual training improved the prediction accuracy of both cycle-GAN and c-GAN. Predicted GPR results of single training were within 3% for 71.2% and 78.8% of test cases for cycle-GAN and c-GAN, respectively. Moreover, similar results for dual training were 82.7% and 88.5% for cycle-GAN and c-GAN, respectively. The error detection model showed high classification accuracy (>98%) for detecting errors related to rotational and translational errors. However, it struggled to differentiate the fluences with "MU scale error" from "error-free" fluences. CONCLUSION We developed a method to automatically generate the synthetic measured fluence and identify errors within them. The proposed dual training improved the PSQA prediction accuracy of both the GAN models, with c-GAN demonstrating superior performance over the cycle-GAN. Our results indicate that the c-GAN with dual training approach combined with error detection model, can accurately generate the synthetic measured fluence for VMAT PSQA and identify the errors. This approach has the potential to pave the way for virtual patient-specific QA of VMAT treatments.
Collapse
Affiliation(s)
- S A Yoganathan
- Department of Radiation Oncology, National Center for Cancer Care & Research (NCCCR), Hamad Medical Corporation, Doha, Qatar
| | - Sharib Ahmed
- Department of Radiation Oncology, National Center for Cancer Care & Research (NCCCR), Hamad Medical Corporation, Doha, Qatar
| | - Satheesh Paloor
- Department of Radiation Oncology, National Center for Cancer Care & Research (NCCCR), Hamad Medical Corporation, Doha, Qatar
| | - Tarraf Torfeh
- Department of Radiation Oncology, National Center for Cancer Care & Research (NCCCR), Hamad Medical Corporation, Doha, Qatar
| | - Souha Aouadi
- Department of Radiation Oncology, National Center for Cancer Care & Research (NCCCR), Hamad Medical Corporation, Doha, Qatar
| | - Noora Al-Hammadi
- Department of Radiation Oncology, National Center for Cancer Care & Research (NCCCR), Hamad Medical Corporation, Doha, Qatar
| | - Rabih Hammoud
- Department of Radiation Oncology, National Center for Cancer Care & Research (NCCCR), Hamad Medical Corporation, Doha, Qatar
| |
Collapse
|
15
|
Chen L, Luo H, Li S, Tan X, Feng B, Yang X, Wang Y, Jin F. Pretreatment patient-specific quality assurance prediction based on 1D complexity metrics and 3D planning dose: classification, gamma passing rates, and DVH metrics. Radiat Oncol 2023; 18:192. [PMID: 37986008 PMCID: PMC10662260 DOI: 10.1186/s13014-023-02376-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Accepted: 11/06/2023] [Indexed: 11/22/2023] Open
Abstract
PURPOSE Highly modulated radiotherapy plans aim to achieve target conformality and spare organs at risk, but the high complexity of the plan may increase the uncertainty of treatment. Thus, patient-specific quality assurance (PSQA) plays a crucial role in ensuring treatment accuracy and providing clinical guidance. This study aims to propose a prediction model based on complexity metrics and patient planning dose for PSQA results. MATERIALS AND METHODS Planning dose, measurement-based reconstructed dose and plan complexity metrics of the 687 radiotherapy plans of patients treated in our institution were collected for model establishing. Global gamma passing rate (GPR, 3%/2mm,10% threshold) of 90% was used as QA criterion. Neural architecture models based on Swin-transformer were adapted to process 3D dose and incorporate 1D metrics to predict QA results. The dataset was divided into training (447), validation (90), and testing (150) sets. Evaluation of predictions was performed using mean absolute error (MAE) for GPR, planning target volume (PTV) HI and PTV CI, mean absolute percentage error (MAPE) for PTV D95, PTV D2 and PTV Dmean, and the area under the receiver operating characteristic (ROC) curve (AUC) for classification. Furthermore, we also compare the prediction results with other models based on either only 1D or 3D inputs. RESULTS In this dataset, 72.8% (500/687) plans passed the pretreatment QA under the criterion. On the testing set, our model achieves the highest performance, with the 1D model slightly surpassing the 3D model. The performance results are as follows (combine, 1D, and 3D transformer): The AUCs are 0.92, 0.88 and 0.86 for QA classification. The MAEs of prediction are 0.039, 0.046, and 0.040 for 3D GPR, 0.018, 0.021, and 0.019 for PTV HI, and 0.075, 0.078, and 0.084 for PTV CI. Specifically, for cases with 3D GPRs greater than 90%, the MAE could achieve 0.020 (combine). The MAPE of prediction is 1.23%, 1.52%, and 1.66% for PTV D95, 2.36%, 2.67%, and 2.45% for PTV D2, and 1.46%, 1.70%, and 1.71% for PTV Dmean. CONCLUSION The model based on 1D complexity metrics and 3D planning dose could predict pretreatment PSQA results with high accuracy and the complexity metrics play a leading role in the model. Furthermore, dose-volume metric deviations of PTV could be predicted and more clinically valuable information could be provided.
Collapse
Affiliation(s)
- Liyuan Chen
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, 400030, China
| | - Huanli Luo
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, 400030, China
| | - Shi Li
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, 400030, China
| | - Xia Tan
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, 400030, China
| | - Bin Feng
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, 400030, China
| | - Xin Yang
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, 400030, China
| | - Ying Wang
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, 400030, China
| | - Fu Jin
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, 400030, China.
| |
Collapse
|
16
|
Fiagbedzi E, Hasford F, Tagoe SN. The influence of artificial intelligence on the work of the medical physicist in radiotherapy practice: a short review. BJR Open 2023; 5:20230003. [PMID: 37942499 PMCID: PMC10630976 DOI: 10.1259/bjro.20230003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Revised: 04/11/2023] [Accepted: 08/02/2023] [Indexed: 11/10/2023] Open
Abstract
There have been many applications and influences of Artificial intelligence (AI) in many sectors and its professionals, that of radiotherapy and the medical physicist is no different. AI and technological advances have necessitated changing roles of medical physicists due to the development of modernized technology with image-guided accessories for the radiotherapy treatment of cancer patients. Given the changing role of medical physicists in ensuring patient safety and optimal care, AI can reshape radiotherapy practice now and in some years to come. Medical physicists' roles in radiotherapy practice have evolved to meet technology for the management of better patient care in the age of modern radiotherapy. This short review provides an insight into the influence of AI on the changing role of medical physicists in each specific chain of the workflow in radiotherapy in which they are involved.
Collapse
Affiliation(s)
| | - Francis Hasford
- Department of Medical Physics, Accra-Ghana, University of Ghana, Accra, Ghana
| | - Samuel Nii Tagoe
- Department of Medical Physics, Accra-Ghana, University of Ghana, Accra, Ghana
| |
Collapse
|
17
|
Zeng L, Zhang M, Zhang Y, Zou Z, Guan Y, Huang B, Yu X, Ding S, Liu Q, Gong C. TransQA: deep hybrid transformer network for measurement-guided volumetric dose prediction of pre-treatment patient-specific quality assurance. Phys Med Biol 2023; 68:205010. [PMID: 37714191 DOI: 10.1088/1361-6560/acfa5e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 09/15/2023] [Indexed: 09/17/2023]
Abstract
Objective. Performing pre-treatment patient-specific quality assurance (prePSQA) is considered an essential, time-consuming, and resource-intensive task for volumetric modulated arc radiotherapy (VMAT) which confirms the dose accuracy and ensure patient safety. Most current machine learning and deep learning approaches stack excessive convolutional/pooling operations (CPs) to predict prePSQA with two-dimensional or one-dimensional information input. However, these models generally present limitations in explicitly modeling long-range dependency for volumetric dose prediction due to the loss of spatial dose features and the inherent locality of CPs. The purpose of this work is to construct a deep hybrid network by combining the self-attention mechanism-based Transformer with modified U-Net for predicting measurement-guided volumetric dose (MDose) of prePSQA.Approach. The enrolled 307 cancer patients underwent VMAT were randomly divided into 246 and 61 cases for training and testing the model. The input data included computed tomography images, radiotherapy dose images exported from the treatment planning system, as well as the MDose distribution from the verification system. The output was the predicted high-quality voxel-wise prePSQA dose distribution.Main results: qualitative and quantitative experimental results show that the proposed prediction method could achieve comparable or better performance on MDose prediction over other approaches in terms of spatial dose distribution, dose-volume histogram metrics, gamma passing rates, mean absolute error, root mean square error, and structural similarity.Significance. The preliminary results on multiple cancer sites show that our approach can be taken as a clinical guidance tool and help medical physicists to reduce the measurement work of prePSQA.
Collapse
Affiliation(s)
- Lingpeng Zeng
- Department of Electronic Information Engineering, Nanchang University, Nanchang, People's Republic of China
| | - Minghui Zhang
- Department of Electronic Information Engineering, Nanchang University, Nanchang, People's Republic of China
| | - Yun Zhang
- Department of Radiation Oncology, Jiangxi Cancer Hospital, Nanchang, Jiangxi 330029, People's Republic of China
| | - Zhongsheng Zou
- Department of Electronic Information Engineering, Nanchang University, Nanchang, People's Republic of China
| | - Yu Guan
- Department of Electronic Information Engineering, Nanchang University, Nanchang, People's Republic of China
| | - Bin Huang
- Department of Electronic Information Engineering, Nanchang University, Nanchang, People's Republic of China
| | - Xiuwen Yu
- Department of Electronic Information Engineering, Nanchang University, Nanchang, People's Republic of China
| | - Shenggou Ding
- Department of Radiation Oncology, Jiangxi Cancer Hospital, Nanchang, Jiangxi 330029, People's Republic of China
| | - Qiegen Liu
- Department of Electronic Information Engineering, Nanchang University, Nanchang, People's Republic of China
| | - Changfei Gong
- Department of Radiation Oncology, Jiangxi Cancer Hospital, Nanchang, Jiangxi 330029, People's Republic of China
| |
Collapse
|
18
|
Tozuka R, Kadoya N, Tomori S, Kimura Y, Kajikawa T, Sugai Y, Xiao Y, Jingu K. Improvement of deep learning prediction model in patient-specific QA for VMAT with MLC leaf position map and patient's dose distribution. J Appl Clin Med Phys 2023; 24:e14055. [PMID: 37261720 PMCID: PMC10562023 DOI: 10.1002/acm2.14055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 04/21/2023] [Accepted: 05/13/2023] [Indexed: 06/02/2023] Open
Abstract
PURPOSE Deep learning-based virtual patient-specific quality assurance (QA) is a novel technique that enables patient QA without measurement. However, this method could be improved by further evaluating the optimal data to be used as input. Therefore, a deep learning-based model that uses multileaf collimator (MLC) information per control point and dose distribution in patient's CT as inputs was developed. METHODS Overall, 96 volumetric-modulated arc therapy plans generated for prostate cancer treatment were used. We developed a model (Model 1) that can predict measurement-based gamma passing rate (GPR) for a treatment plan using data stored as a map reflecting the MLC leaf position at each control point (MLPM) and data of the dose distribution in patient's CT as inputs. The evaluation of the model was based on the mean absolute error (MAE) and Pearson's correlation coefficient (r) between the measured and predicted GPR. For comparison, we also analyzed models trained with the dose distribution in patient's CT alone (Model 2) and with dose distributions recalculated on a virtual phantom CT (Model 3). RESULTS At the 2%/2 mm criterion, MAE[%] and r for Model 1, Model 2, and Model 3 were 2.32% ± 0.43% and 0.54 ± 0.03, 2.70% ± 0.26%, and 0.32 ± 0.08, and 2.96% ± 0.23% and 0.24 ± 0.22, respectively; at the 3%/3 mm criterion, these values were 1.25% ± 0.05% and 0.36 ± 0.18, 1.57% ± 0.35% and 0.19 ± 0.20, and 1.39% ± 0.32% and 0.17 ± 0.22, respectively. This result showed that Model 1 exhibited the lowest MAE and highest r at both criteria of 2%/2 mm and 3%3 mm. CONCLUSIONS These findings showed that a model that combines the MLPM and dose distribution in patient's CT exhibited a better GPR prediction performance compared with the other two studied models.
Collapse
Affiliation(s)
- Ryota Tozuka
- Department of Radiation OncologyTohoku University Graduate School of MedicineSendaiMiyagiJapan
| | - Noriyuki Kadoya
- Department of Radiation OncologyTohoku University Graduate School of MedicineSendaiMiyagiJapan
| | - Seiji Tomori
- Department of RadiologyNational Hospital Organization Sendai Medical CenterSendaiMiyagiJapan
| | - Yuto Kimura
- Radiation Oncology CenterOfuna Chuo HospitalKamakuraJapan
| | - Tomohiro Kajikawa
- Department of Radiation OncologyTohoku University Graduate School of MedicineSendaiMiyagiJapan
- Department of Radiology, Graduate School of Medical ScienceKyoto Prefectural University of MedicineKyotoJapan
| | - Yuto Sugai
- Department of Radiological TechnologyKeio University Hospital, ShinjukuJapan
| | - Yushan Xiao
- Department of Radiation OncologyTohoku University Graduate School of MedicineSendaiMiyagiJapan
| | - Keiichi Jingu
- Department of Radiation OncologyTohoku University Graduate School of MedicineSendaiMiyagiJapan
| |
Collapse
|
19
|
Bin S, Zhang J, Shen L, Zhang J, Wang Q. Study of the prediction of gamma passing rate in dosimetric verification of intensity-modulated radiotherapy using machine learning models based on plan complexity. Front Oncol 2023; 13:1094927. [PMID: 37546404 PMCID: PMC10401596 DOI: 10.3389/fonc.2023.1094927] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 07/04/2023] [Indexed: 08/08/2023] Open
Abstract
Objective To predict the gamma passing rate (GPR) in dosimetric verification of intensity-modulated radiotherapy (IMRT) using three machine learning models based on plan complexity and find the best prediction model by comparing and evaluating the prediction ability of the regression and classification models of three classical algorithms: artificial neural network (ANN), support vector machine (SVM) and random forest (RF). Materials and methods 269 clinical IMRT plans were chosen retrospectively and the GPRs of a total of 2340 fields by the 2%/2mm standard at the threshold of 10% were collected for dosimetric verification using electronic portal imaging device (EPID). Subsequently, the plan complexity feature values of each field were extracted and calculated, and a total of 6 machine learning models (classification and regression models for three algorithms) were trained to learn the relation between 21 plan complexity features and GPRs. Each model was optimized by tuning the hyperparameters and ten-fold cross validation. Finally, the GPRs predicted by the model were compared with measured values to verify the accuracy of the model, and the evaluation indicators were applied to evaluate each model to find the algorithm with the best prediction performance. Results The RF algorithm had the optimal prediction effect on GPR, and its mean absolute error (MAE) on the test set was 1.81%, root mean squared error (RMSE) was 2.14%, and correlation coefficient (CC) was 0.72; SVM was the second and ANN was the worst. Among the classification models, the RF algorithm also had the optimal prediction performance with the highest area under the curve (AUC) value of 0.80, specificity and sensitivity of 0.80 and 0.68 respectively, followed by SVM and the worst ANN. Conclusion All the three classic algorithms, ANN, SVM, and RF, could realize the prediction and classification of GPR. The RF model based on plan complexity had the optimal prediction performance which could save valuable time for quality control workers to improve quality control efficiency.
Collapse
Affiliation(s)
- Shizhen Bin
- Radiotherapy Center, Third Xiangya Hospital of Central South University, Changsha, China
| | - Ji Zhang
- Radiotherapy Center, Third Xiangya Hospital of Central South University, Changsha, China
| | - Luyao Shen
- Radiotherapy Center, The Central Hospital of Shaoyang, Shaoyang, China
| | - Junjun Zhang
- Radiotherapy Center, Third Xiangya Hospital of Central South University, Changsha, China
| | - Qi Wang
- Radiotherapy Center, Third Xiangya Hospital of Central South University, Changsha, China
| |
Collapse
|
20
|
Han C, Zhang J, Yu B, Zheng H, Wu Y, Lin Z, Ning B, Yi J, Xie C, Jin X. Integrating plan complexity and dosiomics features with deep learning in patient-specific quality assurance for volumetric modulated arc therapy. Radiat Oncol 2023; 18:116. [PMID: 37434171 DOI: 10.1186/s13014-023-02311-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Accepted: 06/30/2023] [Indexed: 07/13/2023] Open
Abstract
PURPOSE To investigate the feasibility and performance of deep learning (DL) models combined with plan complexity (PC) and dosiomics features in the patient-specific quality assurance (PSQA) for patients underwent volumetric modulated arc therapy (VMAT). METHODS Total of 201 VMAT plans with measured PSQA results were retrospectively enrolled and divided into training and testing sets randomly at 7:3. PC metrics were calculated using house-built algorithm based on Matlab. Dosiomics features were extracted and selected using Random Forest (RF) from planning target volume (PTV) and overlap regions with 3D dose distributions. The top 50 dosiomics and 5 PC features were selected based on feature importance screening. A DL DenseNet was adapted and trained for the PSQA prediction. RESULTS The measured average gamma passing rate (GPR) of these VMAT plans was 97.94% ± 1.87%, 94.33% ± 3.22%, and 87.27% ± 4.81% at the criteria of 3%/3 mm, 3%/2 mm, and 2%/2 mm, respectively. Models with PC features alone demonstrated the lowest area under curve (AUC). The AUC and sensitivity of PC and dosiomics (D) combined model at 2%/2 mm were 0.915 and 0.833, respectively. The AUCs of DL models were improved from 0.943, 0.849, 0.841 to 0.948, 0.890, 0.942 in the combined models (PC + D + DL) at 3%/3 mm, 3%/2 mm and 2%/2 mm, respectively. A best AUC of 0.942 with a sensitivity, specificity and accuracy of 100%, 81.8%, and 83.6% was achieved with combined model (PC + D + DL) at 2%/2 mm. CONCLUSIONS Integrating DL with dosiomics and PC metrics is promising in the prediction of GPRs in PSQA for patients underwent VMAT.
Collapse
Affiliation(s)
- Ce Han
- Department of Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Ji Zhang
- Department of Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Bing Yu
- Department of Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Haoze Zheng
- Department of Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Yibo Wu
- Department of Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Zhixi Lin
- Department of Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Boda Ning
- Department of Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Jinling Yi
- Department of Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Congying Xie
- Department of Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China.
- Department of Medical and Radiation Oncology, 2nd Affiliated Hospital of Wenzhou Medical University, Wenzhou, China.
| | - Xiance Jin
- Department of Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China.
- School of Basic Medical Science, Wenzhou Medical University, Wenzhou, China.
| |
Collapse
|
21
|
Quintero P, Benoit D, Cheng Y, Moore C, Beavis A. Evaluation of the dataset quality in gamma passing rate predictions using machine learning methods. Br J Radiol 2023; 96:20220302. [PMID: 37129359 PMCID: PMC10321263 DOI: 10.1259/bjr.20220302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 03/12/2023] [Accepted: 04/02/2023] [Indexed: 05/03/2023] Open
Abstract
OBJECTIVE Gamma passing rate (GPR) predictions using machine learning methods have been explored for treatment verification of radiotherapy plans. However, these methods presented datasets with unbalanced number of plans having different treatment conditions (heterogeneous datasets), such as anatomical sites or dose per fractions, leading to lower model interpretability and prediction performance. METHODS We investigated the impact of the dataset composition on GPR binary classification (pass/fail) using random forest (RF), XG-boost, and neural network (NN) models. 945 plans were used to create one reference dataset (randomly assembled) and 24 customized datasets that considered four heterogeneity factors independently (anatomical region, number of arcs, dose per fraction, and treatment unit). 309 predictor features were extracted and calculated from plan parameters, modulation complexity metrics, and radiomic analysis (leave-trajectory maps, 3D dose distributions, and portal dosimetry images). The models' performances were measured using the area under the curve from the receiver operating characteristic (ROC-AUC). RESULTS Radiomics features for reference models increased ROC-AUC values up to 13%, 15%, and 5% for RF, XG-Boost, and NN, respectively. The datasets with higher heterogeneous conditions presented the lower ROC-AUC values (RF: 0.72 ± 0.11, XG-Boost: 0.67 ± 0.1, NN: 0.89 ± 0.05) compared to models with less heterogeneous treatment conditions (RF: 0.88 ± 0.06, XG-Boost: 0.89 ± 0.07, NN: 0.98 ± 0.01). The ten most important features for each heterogeneity dataset group demonstrated their correlation with the treatments' physical aspects and GPR prediction. CONCLUSION Improvements in data generalization and model performances can be associated with datasets having similar treatment conditions. This analysis might be implemented to evaluate the dataset quality and model consistency of further ML applications in radiotherapy. ADVANCES IN KNOWLEDGE Dataset heterogeneities decrease ML model performance and reliability.
Collapse
Affiliation(s)
| | - David Benoit
- Faculty of Science and Engineering, University of Hull, Hull, United Kingdom
| | - Yongqiang Cheng
- Faculty of Science and Engineering, University of Hull, Hull, United Kingdom
| | - Craig Moore
- Medical Physics Service, Castle Hill Hospital, Hull University Teaching Hospitals NHS Trust, Castle Road, Hull, United Kingdom
| | | |
Collapse
|
22
|
Lambri N, Hernandez V, Sáez J, Pelizzoli M, Parabicoli S, Tomatis S, Loiacono D, Scorsetti M, Mancosu P. Multicentric evaluation of a machine learning model to streamline the radiotherapy patient specific quality assurance process. Phys Med 2023; 110:102593. [PMID: 37104920 DOI: 10.1016/j.ejmp.2023.102593] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 03/02/2023] [Accepted: 04/14/2023] [Indexed: 04/29/2023] Open
Abstract
PURPOSE Patient-specific quality assurance (PSQA) is performed to ensure that modulated treatment plans can be delivered as intended, but constitutes a substantial workload that could slow down the radiotherapy process and delay the start of clinical treatments. In this study, we investigated a machine learning (ML) tree-based ensemble model to predict the gamma passing rate (GPR) for volumetric modulated arc therapy (VMAT) plans. MATERIALS AND METHODS 5622 VMAT plans from multiple treatment sites were selected from a database of Institution 1 and the ML model trained using 19 metrics. PSQA analyses were performed automatically using criteria 3%/1 mm (global normalization, absolute dose, 10% threshold) and 95% action limit. Model's performance was evaluated on an out-of-sample test set of Institution 1 and on two independent sets of measurements collected at Institution 2 and Institution 3. Mean absolute error (MAE), as well as the model's sensitivity and specificity, were computed. RESULTS The model obtained a MAE of 2.33%, 2.54% and 3.91% for the three Institutions, with a specificity of 0.90, 0.90 and 0.68, and a sensitivity of 0.61, 0.25, and 0.55, respectively. Small positive median values of the residuals (i.e., the difference between measurements and predictions) were observed for each Institution (0.95%, 1.66%, and 3.42%). Thus, the model's predictions were, on average, close to the real values and provided a conservative estimation of the GPR. CONCLUSIONS ML models can be integrated into clinical practice to streamline the radiotherapy workflow, but they should be center-specific or thoroughly verified within centers before clinical use.
Collapse
Affiliation(s)
- Nicola Lambri
- IRCCS Humanitas Research Hospital, Radiotherapy and Radiosurgery Department, via Manzoni 56, 20089 Rozzano, Milan, Italy; Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20072 Pieve Emanuele, Milan, Italy
| | - Victor Hernandez
- Department of Medical Physics, Hospital Universitari Sant Joan de Reus, IISPV, Tarragona, Spain
| | - Jordi Sáez
- Department of Radiation Oncology, Hospital Clínic de Barcelona, Barcelona, Spain
| | - Marco Pelizzoli
- IRCCS Humanitas Research Hospital, Radiotherapy and Radiosurgery Department, via Manzoni 56, 20089 Rozzano, Milan, Italy; Dipartimento di Fisica "Aldo Pontremoli", Università degli Studi di Milano, Milan, Italy
| | - Sara Parabicoli
- IRCCS Humanitas Research Hospital, Radiotherapy and Radiosurgery Department, via Manzoni 56, 20089 Rozzano, Milan, Italy; Dipartimento di Fisica "Aldo Pontremoli", Università degli Studi di Milano, Milan, Italy
| | - Stefano Tomatis
- IRCCS Humanitas Research Hospital, Radiotherapy and Radiosurgery Department, via Manzoni 56, 20089 Rozzano, Milan, Italy
| | - Daniele Loiacono
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - Marta Scorsetti
- IRCCS Humanitas Research Hospital, Radiotherapy and Radiosurgery Department, via Manzoni 56, 20089 Rozzano, Milan, Italy; Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20072 Pieve Emanuele, Milan, Italy
| | - Pietro Mancosu
- IRCCS Humanitas Research Hospital, Radiotherapy and Radiosurgery Department, via Manzoni 56, 20089 Rozzano, Milan, Italy.
| |
Collapse
|
23
|
Stasko JT, Ferris WS, Adam DP, Culberson WS, Frigo SP. IMRT QA result prediction via MLC transmission decomposition. J Appl Clin Med Phys 2023:e13990. [PMID: 37031363 PMCID: PMC10402675 DOI: 10.1002/acm2.13990] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 03/02/2023] [Accepted: 03/27/2023] [Indexed: 04/10/2023] Open
Abstract
BACKGROUND Quality assurance measurement of IMRT/VMAT treatment plans is resource intensive, and other more efficient methods to achieve the same confidence are desirable. PURPOSE We aimed to analyze treatment plans in the context of the treatment planning systems that created them, in order to predict which ones will fail a standard quality assurance measurement. To do so, we sought to create a tool external to the treatment planning system that could analyze a set of MLC positions and provide information that could be used to calculate various evaluation metrics. METHODS The tool was created in Python to read in DICOM plan files and determine the beam fluence fraction incident on each of seven different zones, each classified based on the RayStation MLC model. The fractions, termed grid point fractions, were validated by analyzing simple test plans. The average grid point fractions, over all control points for 46 plans were then computed. These values were then compared with gamma analysis pass percentages and median dose differences to determine if any significant correlations existed. RESULTS Significant correlation was found between the grid point fraction metrics and median dose differences, but not with gamma analysis pass percentages. Correlations were positive or negative, suggesting differing model parameter value sensitivities, as well as potential insight into the treatment planning system dose model. CONCLUSIONS By decomposing MLC control points into different transmission zones, it is possible to create a metric that predicts whether the analyzed plan will pass a quality assurance measurement from a dose calculation accuracy standpoint. The tool and metrics developed in this work have potential applications in comparing clinical beam models or identifying their weak points. Implementing the tool within a treatment planning system would also provide more potential plan optimization parameters.
Collapse
Affiliation(s)
- John T Stasko
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - William S Ferris
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - David P Adam
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Wesley S Culberson
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Sean P Frigo
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA
| |
Collapse
|
24
|
Baltz GC, Manigold R, Seier R, Kirsner SM. A hybrid method to improve efficiency of patient specific SRS and SBRT QA using 3D secondary dose verification. J Appl Clin Med Phys 2023; 24:e13858. [PMID: 36583305 PMCID: PMC10018667 DOI: 10.1002/acm2.13858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 10/25/2022] [Accepted: 11/20/2022] [Indexed: 12/31/2022] Open
Abstract
PURPOSE Patient Specific QA (PSQA) by direct phantom measurement for all intensity modulated radiation therapy (IMRT) cases is labor intensive and an inefficient use of the Medical Physicist's time. The purpose of this work was to develop a hybrid quality assurance (QA) technique utilizing 3D dose verification as a screening tool to determine if a measurement is necessary. METHODS This study utilized Sun Nuclear DoseCHECK (DC), a 3D secondary verification software, and Fraction 0, a trajectory log IMRT QA software. Twenty-two Lung stereotactic body radiation therapy (SBRT) and thirty single isocentre multi-lesion SRS (MLSRS) plans were retrospectively analysed in DC. Agreement of DC and the TPS dose for selected dosimetric criteria was recorded. Calculated 95% confidence limits (CL) were used to establish action limits. All cases were delivered and measured using the Sun Nuclear stereotactic radiosurgery (SRS) MapCheck. Trajectory logs of the delivery were used to calculate Fraction 0 results for the same criteria calculated by DC. Correlation of DC and Fraction 0 results were calculated. Phantom measured QA was compared to Fraction 0 QA results for the cases which had DC criteria action limits exceeded. RESULTS Correlation of DC and Fraction 0 results were excellent, demonstrating the same action limits could be used for both and DC can predict Fraction 0 results. Based on the calculated action limits, zero lung SBRT cases and six MLSRS cases were identified as requiring a measurement. All plans that passed the DC screening had a passing measurement based PSQA and agreed with Fraction 0 results. CONCLUSION Using 95% CL action limits of dosimetric criteria, a 3D secondary dose verification can be used to determine if a measurement is required for PSQA. This method is efficient for it is part of the normal clinical workflow when verifying any clinical treatment. In addition, it can drastically reduce the number of measurements needed for PSQA.
Collapse
Affiliation(s)
- Garrett C Baltz
- Scripps MD Anderson Cancer Center, San Diego, California, USA
| | - Remy Manigold
- Scripps MD Anderson Cancer Center, San Diego, California, USA
| | - Richard Seier
- Scripps MD Anderson Cancer Center, San Diego, California, USA
| | | |
Collapse
|
25
|
An effective and optimized patient-specific QA workload reduction for VMAT plans after MLC-modelling optimization. Phys Med 2023; 107:102548. [PMID: 36842260 DOI: 10.1016/j.ejmp.2023.102548] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 01/16/2023] [Accepted: 02/13/2023] [Indexed: 02/26/2023] Open
Abstract
INTRODUCTION Many complexity metrics characterize modulated plans. First, this study aimed at identify the optimal complexity metrics to reduce workload associated to patient-specific quality assurance (PSQA) for our equipment and processes. Second, it intended to optimize our MLC modelling to improve measurement and calculation agreement with expectation of further reducing PSQA workload. METHODS Correlation and sensitivity at specificity equals to 1 were evaluated for PSQA results and different complexity metrics. Thresholds to stop PSQA were determined. After validation of the optimal complexity metric and threshold for our equipment and process, the MLC modelling was reviewed with a recently published methodology. This method is based on measurements with a Farmer-type ionization chamber of synchronous and asynchronous sweeping gap plans. Effect on the PSQA results and the identified threshold was investigated. RESULTS In our center, the most appropriate complexity metric for reducing our PSQA workload was the Modulation Complexity Score for VMAT (MCSv). The optimization of the MLC modelling significantly reduced the number of controlled plans, specifically for one of our two Varian Clinac. Any plan with a MCSv >= 0.34 is treated without PSQA. CONCLUSION This study rationalized and reduced our PSQA workload by approximately 30%. It is a continuing work with new TPS, machine or PSQA equipment. It encourages centers to re-evaluate their MLC modelling as well as assess the benefit of complexity metrics to streamline their PSQA workflow. An easier access, at least for reporting, at best for optimizing plans, into the TPS would be beneficial for the community.
Collapse
|
26
|
Cavinato S, Bettinelli A, Dusi F, Fusella M, Germani A, Marturano F, Paiusco M, Pivato N, Rossato MA, Scaggion A. Prediction models as decision-support tools for virtual patient-specific quality assurance of helical tomotherapy plans. Phys Imaging Radiat Oncol 2023; 26:100435. [PMID: 37089905 PMCID: PMC10113896 DOI: 10.1016/j.phro.2023.100435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 03/23/2023] [Accepted: 03/23/2023] [Indexed: 03/30/2023] Open
Abstract
Background and purpose Prediction models may be reliable decision-support tools to reduce the workload associated with the measurement-based patient-specific quality assurance (PSQA) of radiotherapy plans. This study compared the effectiveness of three different models based on delivery parameters, complexity metrics and sinogram radiomics features as tools for virtual-PSQA (vPSQA) of helical tomotherapy (HT) plans. Materials and methods A dataset including 881 RT plans created with two different treatment planning systems (TPSs) was collected. Sixty-five indicators including 12 delivery parameters (DP) and 53 complexity metrics (CM) were extracted using a dedicated software library. Additionally, 174 radiomics features (RF) were extracted from the plans' sinograms. Three groups of variables were formed: A (DP), B (DP + CM) and C (DP + CM + RF). Regression models were trained to predict the gamma index passing rate P R γ (3%G, 2mm) and the impact of each group of variables was investigated. ROC-AUC analysis measured the ability of the models to accurately discriminate between 'deliverable' and 'non-deliverable' plans. Results The best performance was achieved by model C which allowed detecting around 16% and 63% of the 'deliverable' plans with 100% sensitivity for the two TPSs, respectively. In a real clinical scenario, this would have decreased the whole PSQA workload by approximately 35%. Conclusions The combination of delivery parameters, complexity metrics and sinogram radiomics features allows for robust and reliable PSQA gamma passing rate predictions and high-sensitivity detection of a fraction of deliverable plans for one of the two TPSs. Promising yet improvable results were obtained for the other one. The results foster a future adoption of vPSQA programs for HT.
Collapse
|
27
|
Zhu H, Zhu Q, Wang Z, Yang B, Zhang W, Qiu J. Patient-specific quality assurance prediction models based on machine learning for novel dual-layered MLC linac. Med Phys 2023; 50:1205-1214. [PMID: 36342293 DOI: 10.1002/mp.16091] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 10/12/2022] [Accepted: 10/27/2022] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND Patient-specific quality assurance (PSQA) is an indispensable and essential procedure in radiotherapy workflow, and several studies have been done to develop prediction models based on the conventional C-arm linac of single-layered multileaf collimator (MLC) with machine learning (ML) and deep learning techniques to predict PSQA results and improve efficiency. Recently, a newly designed O-ring gantry linac "Halcyon" equipped with unique jawless stacked-and-staggered dual-layered MLC was released. However, few studies have focused on developing PSQA prediction models for this novel dual-layered MLC system. PURPOSE To evaluate the performance of ML to predict PSQA results of fixed field intensity-modulated radiation therapy (FF-IMRT) plans for linac equipped with dual-layered MLC. METHODS AND MATERIALS A total of 213 FF-IMRT treatment plans, including 1383 beams from various treatment sites, were selected and delivered with portal dosimetry verification on Halcyon linac. Gamma analysis was performed using 1%/1, 2%/2, and 3%/2 mm criteria with a 10% threshold. The training set (TS) of ML models consisted of 1106 beams, and an independent evaluation set (ES) consisted of 277 beams. For each beam, 33 complexity metrics were extracted as input data for training models. Three ML algorithms (gradient boosting decision tree/GBDT, random forest/RF, and Poisson Lasso/PL) were utilized to build the models and predict gamma passing rates (GPRs). To improve the prediction accuracy in the rare region, a method of reweighting for TS has been performed and compared to the unweighted results. The importance of complexity metrics was studied by permuted interesting features. RESULTS The GBDT model had the best performance in this study. In ES, the minimal mean prediction error for unweighted results was 1.93%, 1.16%, 0.78% under 1%/1, 2%/2, and 3%/2 mm criteria, respectively, from GBDT model. Comparing to the unweighted results, the models after reweighting gained up to 30% improvement in the rare region, whereas the overall prediction error was slightly worse depending on the kind of models. For feature importance, 2 tree-based models (GBDT and RF) had in common the top 10 most important metrics as well as the same metric with the largest impact. CONCLUSION For linac equipped with novel dual-layered MLC, the ML model based on GBDT algorithm shows a certain degree of accuracy for GPRs prediction. The specific ML model for dual-layered MLC configuration could be a useful tool for physicists detecting PSQA measurement failures.
Collapse
Affiliation(s)
- Heling Zhu
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Qizhen Zhu
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Zhiqun Wang
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Bo Yang
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Wenjun Zhang
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jie Qiu
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
28
|
Matsuura T, Kawahara D, Saito A, Yamada K, Ozawa S, Nagata Y. A synthesized gamma distribution-based patient-specific VMAT QA using a generative adversarial network. Med Phys 2023; 50:2488-2498. [PMID: 36609669 DOI: 10.1002/mp.16210] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 12/23/2022] [Accepted: 12/25/2022] [Indexed: 01/08/2023] Open
Abstract
BACKGROUND Artificial intelligence (AI)-based gamma passing rate (GPR) prediction has been proposed as a time-efficient virtual patient-specific QA method for the delivery of volumetric modulation arc therapy (VMAT). However, there is a limitation that the GPR value loses the locational information of dose accuracy. PURPOSE The objective was to predict the failing points in the gamma distribution and the GPR using a synthesized gamma distribution of VMAT QA with a deep convolutional generative adversarial network (GAN). METHODS The fluence maps of 270 VMAT beams for prostate cancer were measured using an electronic portal imaging device and analyzed using gamma evaluation with 3%/2-mm, 2%/1-mm, 1%/1-mm, and 1%/0.5-mm tolerances. The 270 gamma distributions were divided into two datasets: 240 training datasets for creating a model and 30 test datasets for evaluation. The image prediction network for the fluence maps calculated by the treatment planning system (TPS) to the gamma distributions was created using a GAN. The sensitivity, specificity, and accuracy of detecting failing points were evaluated using measured and synthesized gamma distributions. In addition, the difference between measured GPR (mGPR) and predicted GPR (pGPR) values calculated from the synthesized gamma distributions was evaluated. RESULTS The root mean squared errors between mGPR and pGPR were 1.0%, 2.1%, 3.5%, and 3.6% for the 3%/2-mm, 2%/1-mm, 1%/1-mm, and 1%/0.5-mm tolerances, respectively. The accuracies for detecting failing points were 98.9%, 96.9%, 94.7%, and 93.7% for 3%/2-mm, 2%/1-mm, 1%/1-mm, and 1%/0.5-mm tolerances, respectively. The sensitivity and specificity were the highest for 1%/0.5-mm and 3%/2-mm tolerances, which were 82.7% and 99.6%, respectively. CONCLUSIONS We developed a novel system using a GAN to generate a synthesized gamma distribution-based patient-specific VMAT QA. The system is promising from the point of view of quality assurance in radiotherapy because it shows high performance and can detect failing points.
Collapse
Affiliation(s)
- Takaaki Matsuura
- Hiroshima High-Precision Radiotherapy Cancer Center, Hiroshima, Japan.,Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Daisuke Kawahara
- Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Akito Saito
- Department of Radiation Oncology, Hiroshima University Hospital, Hiroshima, Japan
| | - Kiyoshi Yamada
- Hiroshima High-Precision Radiotherapy Cancer Center, Hiroshima, Japan
| | - Shuichi Ozawa
- Hiroshima High-Precision Radiotherapy Cancer Center, Hiroshima, Japan.,Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Yasushi Nagata
- Hiroshima High-Precision Radiotherapy Cancer Center, Hiroshima, Japan.,Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
29
|
Cavinato S, Fusella M, Paiusco M, Scaggion A. Quantitative assessment of helical tomotherapy plans complexity. J Appl Clin Med Phys 2022; 24:e13781. [PMID: 36523156 PMCID: PMC9860001 DOI: 10.1002/acm2.13781] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 07/20/2022] [Accepted: 08/16/2022] [Indexed: 12/23/2022] Open
Abstract
PURPOSE An unnecessary amount of complexity in radiotherapy plans affects the efficiency of the treatments, increasing the uncertainty of dose deposition and its susceptibility to anatomical changes or setup errors. To date, tools for quantitatively assessing the complexity of tomotherapy plans are still limited. In this study, new metrics were developed to characterize different aspects of helical tomotherapy (HT) plans, and their actual effectiveness was investigated. METHODS The complexity of 464 HT plans delivered on a Radixact platform was evaluated. A new set of metrics was devised to assess beam geometry, leaf opening time (LOT) variability, and modulation over space and time. Sixty-five complexity metrics were extracted from the dataset using the newly in-house developed software library TCoMX: 29 metrics already proposed in the literature and 36 newly developed metrics. Their reciprocal relation is discussed. Their effectiveness was evaluated through correlation analyses with patient-specific quality assurance (PSQA) results. RESULTS An inverse linear relation was found between the average number of closed leaves and the average number of MLC openings and closures as well as between the choice of the modulation factor and the discontinuity of the field, suggesting some intrinsic link between the LOT distribution and the geometrical complexity of the MLC openings. The newly proposed metrics were at least as correlated as the existing ones to the PSQA results. Metrics describing the geometrical complexity of the MLC openings showed the strongest connection to the PSQA results. Significant correlations were found between at least one of the new metrics and the γ index passing rate P R γ % ( 3 % G , 2 mm ) $P{R}_{\gamma}\%(3\%G,2\textit{mm})$ for six out of seven groups of plans considered. CONCLUSION The new metrics proposed were shown to be effective to characterize more comprehensively the complexity of HT plans. A software library for their automatic extraction is described and made available.
Collapse
Affiliation(s)
- Samuele Cavinato
- Medical Physics DepartmentVeneto Institute of Oncology IOV‐IRCCSPadovaItaly,Dipartimento di Fisica e Astronomia “G. Galilei”Università degli Studi di PadovaPadovaItaly
| | - Marco Fusella
- Medical Physics DepartmentVeneto Institute of Oncology IOV‐IRCCSPadovaItaly
| | - Marta Paiusco
- Medical Physics DepartmentVeneto Institute of Oncology IOV‐IRCCSPadovaItaly
| | | |
Collapse
|
30
|
Salari E, Shuai Xu K, Sperling NN, Parsai EI. Using machine learning to predict gamma passing rate in volumetric-modulated arc therapy treatment plans. J Appl Clin Med Phys 2022; 24:e13824. [PMID: 36495010 PMCID: PMC9924108 DOI: 10.1002/acm2.13824] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 09/19/2022] [Accepted: 10/05/2022] [Indexed: 12/14/2022] Open
Abstract
PURPOSE This study aims to develop an algorithm to predict gamma passing rate (GPR) in the volumetric-modulated arc therapy (VMAT) technique. MATERIALS AND METHODS A total of 118 clinical VMAT plans, including 28 mediastina, 25 head and neck, 40 brains intensity-modulated radiosurgery, and 25 prostate cases, were created in RayStation treatment planning system for Edge and TrueBeam linacs. In-house scripts were developed to compute Modulation indices such as plan-averaged beam area (PA), plan-averaged beam irregularity (PI), total monitor unit (MU), leaf travel/arc length, mean dose rate variation, and mean gantry speed variation. Pretreatment verifications were performed on ArcCHECK phantom with SNC software. GPR was calculated with 3%/2 mm and 10% threshold. The dataset was randomly split into a training (70%) and a test (30%) dataset. A random forest regression (RFR) model and support vector regression (SVR) with linear kernel were trained to predict GPR using the complexity metrics as input. The prediction performance was evaluated by calculating the mean absolute error (MAE), R2 , and root mean square error (RMSE). RESULTS RMSEs at γ 3%/2 mm for RFR and SVR were 1.407 ± 0.103 and 1.447 ± 0.121, respectively. MAE was 1.14 ± 0.084 for RFR and 1.101 ± 0.09 for SVR. R2 was equal to 0.703 ± 0.027 and 0.689 ± 0.053 for RFR and SVR, respectively. GPR of 3%/2 mm with a 10% threshold can be predicted with an error smaller than 3% for 94% of plans using RFR and SVR models. The most important metrics that had the greatest impact on how accurately GPR can be predicted were determined to be the PA, PI, and total MU. CONCLUSION In terms of its prediction values and errors, SVR (linear) appeared to be comparable with RFR for this dataset. Based on our results, the PA, PI, and total MU calculations may be useful in guiding VMAT plan evaluation and ultimately reducing uncertainties in planning and radiation delivery.
Collapse
Affiliation(s)
- Elahheh Salari
- Department of Radiation OncologyUniversity of Toledo Medical CenterToledoOhioUSA
| | - Kevin Shuai Xu
- Department of Computer and Data SciencesCase Western Reserve UniversityClevelandOhioUSA
| | | | - E. Ishmael Parsai
- Department of Radiation OncologyUniversity of Toledo Medical CenterToledoOhioUSA
| |
Collapse
|
31
|
Quintero P, Benoit D, Cheng Y, Moore C, Beavis A. Machine learning-based predictions of gamma passing rates for virtual specific-plan verification based on modulation maps, monitor unit profiles, and composite dose images. Phys Med Biol 2022; 67. [PMID: 36384046 DOI: 10.1088/1361-6560/aca38a] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2022] [Accepted: 11/16/2022] [Indexed: 11/18/2022]
Abstract
Machine learning (ML) methods have been implemented in radiotherapy to aid virtual specific-plan verification protocols, predicting gamma passing rates (GPR) based on calculated modulation complexity metrics because of their direct relation to dose deliverability. Nevertheless, these metrics might not comprehensively represent the modulation complexity, and automatically extracted features from alternative predictors associated with modulation complexity are needed. For this reason, three convolutional neural networks (CNN) based models were trained to predict GPR values (regression and classification), using respectively three predictors: (1) the modulation maps (MM) from the multi-leaf collimator, (2) the relative monitor units per control point profile (MUcp), and (3) the composite dose image (CDI) used for portal dosimetry, from 1024 anonymized prostate plans. The models' performance was assessed for classification and regression by the area under the receiver operator characteristic curve (AUC_ROC) and Spearman's correlation coefficient (r). Finally, four hybrid models were designed using all possible combinations of the three predictors. The prediction performance for the CNN-models using single predictors (MM, MUcp, and CDI) were AUC_ROC = 0.84 ± 0.03, 0.77 ± 0.07, 0.75 ± 0.04, andr= 0.6, 0.5, 0.7. Contrastingly, the hybrid models (MM + MUcp, MM + CDI, MUcp+CDI, MM + MUcp+CDI) performance were AUC_ROC = 0.94 ± 0.03, 0.85 ± 0.06, 0.89 ± 0.06, 0.91 ± 0.03, andr= 0.7, 0.5, 0.6, 0.7. The MP, MUcp, and CDI are suitable predictors for dose deliverability models implementing ML methods. Additionally, hybrid models are susceptible to improving their prediction performance, including two or more input predictors.
Collapse
Affiliation(s)
- Paulo Quintero
- Faculty of Science and Engineering, University of Hull, Hull, United Kingdom.,Medical Physics Department, Queen's Centre for Oncology, Hull University Teaching Hospitals NHS Trust, Cottingham, United Kingdom
| | - David Benoit
- Faculty of Science and Engineering, University of Hull, Hull, United Kingdom
| | - Yongqiang Cheng
- Faculty of Science and Engineering, University of Hull, Hull, United Kingdom
| | - Craig Moore
- Medical Physics Department, Queen's Centre for Oncology, Hull University Teaching Hospitals NHS Trust, Cottingham, United Kingdom
| | - Andrew Beavis
- Medical Physics Department, Queen's Centre for Oncology, Hull University Teaching Hospitals NHS Trust, Cottingham, United Kingdom.,Faculty of Health and Wellbeing, Sheffield Hallam University, Sheffield, United Kingdom.,Faculty of Health Sciences, University of Hull, Hull, United Kingdom
| |
Collapse
|
32
|
Gong C, Zhu K, Lin C, Han C, Lu Z, Chen Y, Yu C, Hou L, Zhou Y, Yi J, Ai Y, Xiang X, Xie C, Jin X. Efficient dose-volume histogram-based pretreatment patient-specific quality assurance methodology with combined deep learning and machine learning models for volumetric modulated arc radiotherapy. Med Phys 2022; 49:7779-7790. [PMID: 36190117 DOI: 10.1002/mp.16010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 08/26/2022] [Accepted: 09/17/2022] [Indexed: 12/27/2022] Open
Abstract
BACKGROUND Weak correlation between gamma passing rates and dose differences in target volumes and organs at risk (OARs) has been reported in several studies. Evaluation on the differences between planned dose-volume histogram (DVH) and reconstructed DVH from measurement was adopted and incorporated into patient-specific quality assurance (PSQA). However, it is difficult to develop a methodology allowing the evaluation of errors on DVHs accurately and quickly. PURPOSE To develop a DVH-based pretreatment PSQA for volumetric modulated arc therapy (VMAT) with combined deep learning (DL) and machine learning models to overcome the limitation of conventional gamma index (GI) and improve the efficiency of DVH-based PSQA. METHODS A DL model with a three-dimensional squeeze-and-excitation residual blocks incorporated into a modified U-net was developed to predict the measured PSQA DVHs of 208 head-and-neck (H&N) cancer patients underwent VMAT between 2018 and 2021 from two hospitals, in which 162 cases was randomly selected for training, 18 for validation, and 28 for testing. After evaluating the differences between treatment planning system (TPS) and PSQA DVHs predicted by DL model with multiple metrics, a pass or fail (PoF) classification model was developed using XGBoost algorithm. Evaluation of domain experts on dose errors between TPS and reconstructed PSQA DVHs was taken as ground truth for PoF classification model training. RESULTS The prediction model was able to achieve a good agreement between predicted, measured, and TPS doses. Quantitative evaluation demonstrated no significant difference between predicted PSQA dose and measured dose for target and OARs, except for Dmean of PTV6900 (p = 0.001), D50 of PTV6000 (p = 0.014), D2 of PTV5400 (p = 0.009), D50 of left parotid (p = 0.015), and Dmax of left inner ear (p = 0.007). The XGBoost model achieved an area under curves, accuracy, sensitivity, and specificity of 0.89 versus 0.88, 0.89 versus 0.86, 0. 71 versus 0.71, and 0.95 versus 0.91 with measured and predicted PSQA doses, respectively. The agreement between domain experts and the classification model was 86% for 28 test cases. CONCLUSIONS The successful prediction of PSQA doses and classification of PoF for H&N VMAT PSQA indicating that this DVH-based PSQA method is promising to overcome the limitations of GI and to improve the efficiency and accuracy of VMAT delivery.
Collapse
Affiliation(s)
- Changfei Gong
- Radiation Oncology Department, 1st Affiliated Hospital of Nanchang Medical University, Nanchang, China.,Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Kecheng Zhu
- Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Chengyin Lin
- Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Ce Han
- Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Zhongjie Lu
- Radiation Oncology Department, 1st Affiliated Hospital of Medical School of Zhejiang University, Zhejiang, China
| | - Yuanhua Chen
- Radiation Oncology Department, 1st Affiliated Hospital of Medical School of Zhejiang University, Zhejiang, China
| | - Changhui Yu
- Radiation Oncology Department, Taizhou Hospital of Zhejiang Province, Taizhou, China
| | - Liqiao Hou
- Radiation Oncology Department, Taizhou Hospital of Zhejiang Province, Taizhou, China
| | - Yongqiang Zhou
- Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Jinling Yi
- Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Yao Ai
- Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Xiaojun Xiang
- Radiation Oncology Department, 1st Affiliated Hospital of Nanchang Medical University, Nanchang, China
| | - Congying Xie
- Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China.,Radiation Oncology Department, 2nd Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Xiance Jin
- Radiotherapy Center, 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou, China.,School of Basic Medical Science, Wenzhou Medical University, Wenzhou, China
| |
Collapse
|
33
|
Predictive gamma passing rate of 3D detector array-based volumetric modulated arc therapy quality assurance for prostate cancer via deep learning. Phys Eng Sci Med 2022; 45:1073-1081. [PMID: 36202950 DOI: 10.1007/s13246-022-01172-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 08/04/2022] [Indexed: 11/07/2022]
Abstract
To predict the gamma passing rate (GPR) of the three-dimensional (3D) detector array-based volumetric modulated arc therapy (VMAT) quality assurance (QA) for prostate cancer using a convolutional neural network (CNN) with the 3D dose distribution. One hundred thirty-five VMAT plans for prostate cancer were selected: 110 plans were used for training and validation, and 25 plans were used for testing. Verification plans were measured using a helical 3D diode array (ArcCHECK). The dose distribution on the detector element plane of these verification plans was used as input data for the CNN model. The measured GPR (mGPR) values were used as the training data. The CNN model comprises eighteen layers and predicted GPR (pGPR) values. The mGPR and pGPR values were compared, and a cumulative frequency histogram of the prediction error was created to clarify the prediction error tendency. The correlation coefficients of pGPR and mGPR were 0.67, 0.69, 0.66, and 0.73 for 3%/3-mm, 3%/2-mm, 2%/3-mm, and 2%/2-mm gamma criteria, respectively. The respective mean±standard deviations of pGPR-mGPR were -0.87±2.18%, -0.65±2.93%, -0.44±2.53%, and -0.71±3.33%. The probabilities of false positive error cases (pGPR < mGPR) were 72%, 60%, 68%, and 56% for each gamma criterion. We developed a deep learning-based prediction model of the 3D detector array-based VMAT QA for prostate cancer, and evaluated the accuracy and tendency of prediction GPR. This model can provide a proactive estimation for the results of the patient-specific QA before the verification measurement.
Collapse
|
34
|
Tanaka S, Kadoya N, Sugai Y, Umeda M, Ishizawa M, Katsuta Y, Ito K, Takeda K, Jingu K. A deep learning-based radiomics approach to predict head and neck tumor regression for adaptive radiotherapy. Sci Rep 2022; 12:8899. [PMID: 35624113 PMCID: PMC9142601 DOI: 10.1038/s41598-022-12170-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Accepted: 05/05/2022] [Indexed: 12/14/2022] Open
Abstract
Early regression—the regression in tumor volume during the initial phase of radiotherapy (approximately 2 weeks after treatment initiation)—is a common occurrence during radiotherapy. This rapid radiation-induced tumor regression may alter target coordinates, necessitating adaptive radiotherapy (ART). We developed a deep learning-based radiomics (DLR) approach to predict early head and neck tumor regression and thereby facilitate ART. Primary gross tumor volume (GTVp) was monitored in 96 patients and nodal GTV (GTVn) in 79 patients during treatment. All patients underwent two computed tomography (CT) scans: one before the start of radiotherapy for initial planning and one during radiotherapy for boost planning. Patients were assigned to regression and nonregression groups according to their median tumor regression rate (ΔGTV/treatment day from initial to boost CT scan). We input a GTV image into the convolutional neural network model, which was pretrained using natural image datasets, via transfer learning. The deep features were extracted from the last fully connected layer. To clarify the prognostic power of the deep features, machine learning models were trained. The models then predicted the regression and nonregression of GTVp and GTVn and evaluated the predictive performance by 0.632 + bootstrap area under the curve (AUC). Predictive performance for GTVp regression was highest using the InceptionResNetv2 model (mean AUC = 0.75) and that for GTVn was highest using NASNetLarge (mean AUC = 0.73). Both models outperformed the handcrafted radiomics features (mean AUC = 0.63 for GTVp and 0.61 for GTVn) or clinical factors (0.64 and 0.67, respectively). DLR may facilitate ART for improved radiation side-effects and target coverage.
Collapse
Affiliation(s)
- Shohei Tanaka
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| | - Noriyuki Kadoya
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan.
| | - Yuto Sugai
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| | - Mariko Umeda
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| | - Miyu Ishizawa
- Department of Radiological Technology, School of Health Sciences, Faculty of Medicine, Tohoku University, Sendai, Japan
| | - Yoshiyuki Katsuta
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| | - Kengo Ito
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| | - Ken Takeda
- Department of Radiological Technology, School of Health Sciences, Faculty of Medicine, Tohoku University, Sendai, Japan
| | - Keiichi Jingu
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| |
Collapse
|
35
|
Thongsawad S, Srisatit S, Fuangrod T. Predicting gamma evaluation results of patient-specific head and neck volumetric-modulated arc therapy quality assurance based on multileaf collimator patterns and fluence map features: A feasibility study. J Appl Clin Med Phys 2022; 23:e13622. [PMID: 35584035 PMCID: PMC9278677 DOI: 10.1002/acm2.13622] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 03/29/2022] [Accepted: 04/07/2022] [Indexed: 12/24/2022] Open
Abstract
The purpose of this study was to develop a predictive model for patient-specific VMAT QA results using multileaf collimator (MLC) effect and texture analysis. The MLC speed, acceleration and texture analysis features were extracted from 106 VMAT plans as predictors. Gamma passing rate (GPR) was collected as a response class with gamma criteria of 2%/2 mm and 3%/2 mm. The model was trained using two machine learning methods: AdaBoost classification and bagged regression trees model. GPR was classified into the "PASS" and "FAIL" for the classification model using the institutional warning level. The accuracy of the model was assessed using sensitivity and specificity. In addition, the accuracy of the regression model was determined using the difference between predicted and measured GPR. For the AdaBoost classification model, the sensitivity/specificity was 94.12%/100% and 63.63%/53.13% at gamma criteria of 2%/2 mm and 3%/2 mm, respectively. For the bagged regression trees model, the sensitivity/specificity was 94.12%/91.89% and 61.18%/68.75% at gamma criteria of 2%/2 mm and 3%/2 mm, respectively. The root mean square error (RMSE) of difference between predicted and measured GPR was found at 2.44 and 1.22 for gamma criteria of 2%/2 mm and 3%/2 mm, respectively. The promising result was found at tighter gamma criteria 2%/2 mm with 94.12% sensitivity (both bagged regression trees and AdaBoost classification model) and 100% specificity (AdaBoost classification model).
Collapse
Affiliation(s)
- Sangutid Thongsawad
- Department of Nuclear Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand.,Princess Srisavangavadhana College of Medicine, Chulabhorn Royal Academy, Bangkok, Thailand
| | - Somyot Srisatit
- Department of Nuclear Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand
| | - Todsaporn Fuangrod
- Princess Srisavangavadhana College of Medicine, Chulabhorn Royal Academy, Bangkok, Thailand
| |
Collapse
|
36
|
Wang W, Chang Y, Liu Y, Liang Z, Liao Y, Qin B, Liu X, Yang Z. Feasibility study of fast intensity-modulated proton therapy dose prediction method using deep neural networks for prostate cancer. Med Phys 2022; 49:5451-5463. [PMID: 35543109 DOI: 10.1002/mp.15702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 04/20/2022] [Accepted: 04/28/2022] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Compared to the pencil-beam algorithm, the Monte-Carlo (MC) algorithm is more accurate for dose calculation but time-consuming in proton therapy. To solve this problem, this study uses deep learning to provide fast 3D dose prediction for prostate cancer patients treated with intensity-modulated proton therapy (IMPT). METHODS A novel recurrent U-net (RU-net) architecture was trained to predict the 3D dose distribution. Doses, CT images, and beam spot information from IMPT plans were used to train the RU-net with a 5-fold cross-validation. However, predicting the complicated dose properties of the IMPT plan is difficult for neural networks. Instead of the Peak-MU model, this work develops the Multi-MU model that adopted more comprehensive inputs and was trained with a combinational loss function. The dose difference between the prediction dose and MC dose was evaluated with gamma analysis, dice similarity coefficient (DSC), and dose-volume histogram (DVH) metrics. The Monte-Carlo dropout was also added to the network to quantify the uncertainty of the model. RESULTS Compared to the Peak-MU model, the Multi-MU model led to smaller mean absolute errors (3.03% vs. 2.05%, p = 0.005), higher gamma-passing rate (2mm, 3%: 97.42% vs. 93.69%, p = 0.005), higher dice similarity coefficient, and smaller relative DVH metrics error (CTV D98% : 3.03% vs. 6.08%, p = 0.017; in Bladder V30: 3.08% vs. 5.28%, p = 0.028; and in Bladder V20: 3.02% vs. 4.42%, p = 0.017). Considering more prior knowledge, the Multi-MU model had better-predicted accuracy with a prediction time of less than half a second for each fold. The mean uncertainty value of the Multi-MU model is 0.46%, with a dropout rate of 10%. CONCLUSION This method was a nearly real-time IMPT dose prediction algorithm with accuracy comparable to the PB analytical algorithms used in prostate cancer. This RU-net might be used in plan robustness optimization and robustness evaluation in the future. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Wei Wang
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Yu Chang
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
| | - Yilin Liu
- Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, TX, 77030-3722, USA.,Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | - Zhikai Liang
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Yicheng Liao
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Bin Qin
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Xu Liu
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Zhiyong Yang
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
| |
Collapse
|
37
|
Hao Y, Zhang X, Wang J, Zhao T, Sun B. Improvement of IMRT QA prediction using imaging-based neural architecture search. Med Phys 2022; 49:5236-5243. [PMID: 35524570 DOI: 10.1002/mp.15694] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 04/09/2022] [Accepted: 04/25/2022] [Indexed: 11/09/2022] Open
Abstract
PURPOSE Machine learning has been used to predict the gamma passing rate of Intensity-modulated radiation therapy (IMRT) QA results. In this work, we applied a novel neural architecture search to automatically tune and search for the best deep neural networks instead of using hand-designed deep learning architectures. METHOD AND MATERIALS One hundred and eighty-two IMRT plans were created and delivered with portal dosimetry. A total of 1497 fields for multiple treatment sites were delivered and measured by portal imagers. Gamma criteria of 2%/2mm with a 5% threshold were used. Fluence maps calculated for each plan were used as inputs to a convolution neural network (CNN). Auto-Keras was implemented to search for the best CNN architecture for fluence image regression. The network morphism was adopted in the searching process, in which the base models were ResNet and DenseNet. The performance of this CNN approach was compared with tree-based machine learning models previously developed for this application, using the same data set. RESULTS The deep-learning-based approach had 98.3% of predictions within 3% of the measured 2%/2mm gamma passing rates with a maximum error of 3.1% and a mean absolute error of less than 1%. Our results show that this novel architecture search approach achieves comparable performance to the machine-learning-based approaches with handcrafted features. CONCLUSIONS We implemented a novel CNN model using imaging-based neural architecture for IMRT QA prediction. The imaging-based deep-learning method does not require manual extraction of relevant features and is able to automatically select the best network architecture. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Yao Hao
- Department of Radiation Oncology, Washington University School of Medicine, 660 S. Euclid Ave, St. Louis, MO, 63110
| | - Xizhe Zhang
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing, China
| | - Jie Wang
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing, China
| | - Tianyu Zhao
- Department of Radiation Oncology, Washington University School of Medicine, 660 S. Euclid Ave, St. Louis, MO, 63110
| | - Baozhou Sun
- Department of Radiation Oncology, Washington University School of Medicine, 660 S. Euclid Ave, St. Louis, MO, 63110
| |
Collapse
|
38
|
Wall PDH, Hirata E, Morin O, Valdes G, Witztum A. Prospective clinical validation of virtual patient-specific quality assurance of VMAT radiation therapy plans. Int J Radiat Oncol Biol Phys 2022; 113:1091-1102. [PMID: 35533908 DOI: 10.1016/j.ijrobp.2022.04.040] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 04/05/2022] [Accepted: 04/27/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE Performing measurement-based patient-specific quality assurance (PSQA) is recognized as a resource-intensive and time inefficient task in the radiotherapy treatment workflow. Paired with technological refinements in modern radiotherapy, research towards measurement-free PSQA has seen increased interest over the last five years. However, these efforts have not been clinically implemented or prospectively validated in the U.S. We propose a virtual QA (VQA) system and workflow to assess the safety and workload reduction of measurement-free PSQA. METHODS An XGBoost machine learning model was designed to predict PSQA outcomes of VMAT plans, represented as percent differences between the measured ion chamber point dose in a phantom and the corresponding planned dose. The final model was deployed within a web application to predict PSQA outcomes of clinical plans within an existing clinical workflow. The application also displays relevant feature importance and plan-specific distribution analyses relative to database plans for documentation and to aid physicist interpretation and evaluation. VQA predictions were prospectively validated over three months of measurements at our clinic to assess safety and efficiency gains. RESULTS Over three months, VQA predictions for 445 VMAT plans were prospectively validated at our institution. VQA predictions for these plans had a mean absolute error of 1.08 +/- 0.77%, with a maximum absolute error of 2.98%. Employing a 1% prediction threshold (i.e. plans predicted to have an absolute error of less than 1% would not require a measurement) would yield a 69.2% reduction in QA workload - saving 32.5 hours per month on average - with 81.5%/72.4%/0.81 sensitivity/specificity/AUC at a 3% clinical threshold and 100%/70%/0.93 sensitivity/specificity/AUC at a 4% clinical threshold. CONCLUSION This is the first prospective clinical implementation and validation of VQA in the U.S., which we observed to be efficient. Using a conservative threshold, VQA can substantially reduce the number of required measurements for PSQA, leading to more effective allocation of clinical resources.
Collapse
Affiliation(s)
- Phillip D H Wall
- Department of Radiation Oncology, University of California, San Francisco, USA.
| | - Emily Hirata
- Department of Radiation Oncology, University of California, San Francisco, USA
| | - Olivier Morin
- Department of Radiation Oncology, University of California, San Francisco, USA
| | - Gilmer Valdes
- Department of Radiation Oncology, University of California, San Francisco, USA
| | - Alon Witztum
- Department of Radiation Oncology, University of California, San Francisco, USA
| |
Collapse
|
39
|
Uncertainty-guided man-machine integrated patient-specific quality assurance. Radiother Oncol 2022; 173:1-9. [DOI: 10.1016/j.radonc.2022.05.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2021] [Revised: 05/13/2022] [Accepted: 05/17/2022] [Indexed: 01/22/2023]
|
40
|
Noblet C, Duthy M, Coste F, Saliou M, Samain B, Drouet F, Papazyan T, Moreau M. Implementation of volumetric-modulated arc therapy for locally advanced breast cancer patients: Dosimetric comparison with deliverability consideration of planning techniques and predictions of patient-specific QA results via supervised machine learning. Phys Med 2022; 96:18-31. [DOI: 10.1016/j.ejmp.2022.02.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 01/10/2022] [Accepted: 02/15/2022] [Indexed: 12/21/2022] Open
|
41
|
Huang Y, Pi Y, Ma K, Miao X, Fu S, Zhu Z, Cheng Y, Zhang Z, Chen H, Wang H, Gu H, Shao Y, Duan Y, Feng A, Zhuo W, Xu Z. Deep Learning for Patient-Specific Quality Assurance: Predicting Gamma Passing Rates for IMRT Based on Delivery Fluence Informed by log Files. Technol Cancer Res Treat 2022; 21:15330338221104881. [PMID: 35726209 PMCID: PMC9218492 DOI: 10.1177/15330338221104881] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
Objectives: In this study, we propose a deep learning-based approach to predict Intensity-modulated radiation therapy (IMRT) quality assurance (QA) gamma passing rates using delivery fluence informed by log files. Methods: A total of 112 IMRT plans for chest cancers were planned and measured by portal dosimetry equipped on TrueBeam linac. The convolutional neural network (CNN) based learning model was trained using delivery fluence as inputs and gamma passing rates (GPRs) of 4 different criteria (3%/3 mm, 2%/3 mm, 3%/2 mm, and 2%/2 mm) as outputs. Model performance for both validation and test sets was assessed using mean absolute error (MAE), mean squared error (MSE), root MSE (RMSE), Spearman rank correlation coefficients (Sr), and Determination coefficient (R2) between the measured and predicted GPR values. Results: In the test set, the MAE of the prediction model were 0.402, 0.511, 1.724, and 2.530, the MSE were 0.640, 0.986, 6.654, and 9.508, the RMSE were 0.800, 0.993, 2.580, and 3.083, the Sr were 0.643, 0.684, 0.821, and 0.824 (P < .001) and the R2 were 0.4110, 0.4666, 0.6677, and 0.6769 for 3%/3 mm, 3%/2 mm, 2%/3 mm, and 2%/2 mm, respectively. The MAE and RMSE of the prediction model decreased with stricter gamma criteria while the Sr and R2 between measured and predicted GPR values increased. Conclusions: The CNN prediction model based on delivery fluence informed by log files could accurately predict IMRT QA passing rates for different gamma criteria. It could reduce QA workload and improve efficiency in pretreatment QA. Our results suggest that the CNN prediction model based on delivery fluence informed by log files may be a promising tool for the gamma evaluation of IMRT QA.
Collapse
Affiliation(s)
- Ying Huang
- 71141Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Yifei Pi
- Department of Radiation Oncology, 191599The First Affiliated Hospital of Zhengzhou University, Henan, China
| | - Kui Ma
- Varian Medical Systems, Beijing, China
| | - Xiaojuan Miao
- The General Hospital of Western Theater Command PLA, Chengdu, China
| | - Sichao Fu
- The General Hospital of Western Theater Command PLA, Chengdu, China
| | - Zhen Zhu
- 71141Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Yifan Cheng
- 71141Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Zhepei Zhang
- 71141Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Hua Chen
- 71141Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Hao Wang
- 71141Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Hengle Gu
- 71141Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Yan Shao
- 71141Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Yanhua Duan
- 71141Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Aihui Feng
- 71141Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Weihai Zhuo
- Key Lab of Nuclear Physics & Ion-Beam Application (MOE), 12478Fudan University, Shanghai, China
| | - Zhiyong Xu
- 71141Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
42
|
Hu T, Xie L, Zhang L, Li G, Yi Z. Deep Multimodal Neural Network Based on Data-Feature Fusion for Patient-Specific Quality Assurance. Int J Neural Syst 2021; 32:2150055. [PMID: 34895106 DOI: 10.1142/s0129065721500556] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Patient-specific quality assurance (QA) for Volumetric Modulated Arc Therapy (VMAT) plans is routinely performed in the clinical. However, it is labor-intensive and time-consuming for medical physicists. QA prediction models can address these shortcomings and improve efficiency. Current approaches mainly focus on single cancer and single modality data. They are not applicable to clinical practice. To assess the accuracy of QA results for VMAT plans, this paper presents a new model that learns complementary features from the multi-modal data to predict the gamma passing rate (GPR). According to the characteristics of VMAT plans, a feature-data fusion approach is designed to fuse the features of imaging and non-imaging information in the model. In this study, 690 VMAT plans are collected encompassing more than ten diseases. The model can accurately predict the most VMAT plans at all three gamma criteria: 2%/2 mm, 3%/2 mm and 3%/3 mm. The mean absolute error between the predicted and measured GPR is 2.17%, 1.16% and 0.71%, respectively. The maximum deviation between the predicted and measured GPR is 3.46%, 4.6%, 8.56%, respectively. The proposed model is effective, and the features of the two modalities significantly influence QA results.
Collapse
Affiliation(s)
- Ting Hu
- Department of Computer Science and Technology, Sichuan University, Section 4, Southern 1st Ring Rd, Chengdu, Sichuan, P. R. China
| | - Lizhang Xie
- Department of Computer Science and Technology, Sichuan University, Section 4, Southern 1st Ring Rd, Chengdu, Sichuan, P. R. China
| | - Lei Zhang
- Department of Computer Science and Technology, Sichuan University, Section 4, Southern 1st Ring Rd, Chengdu, Sichuan, P. R. China
| | - Guangjun Li
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, P. R. China
| | - Zhang Yi
- Department of Computer Science and Technology, Sichuan University, Section 4, Southern 1st Ring Rd, Chengdu, Sichuan, P. R. China
| |
Collapse
|
43
|
Gao Y, Xiong J, Shen C, Jia X. Improving robustness of a deep learning-based lung-nodule classification model of CT images with respect to image noise. Phys Med Biol 2021; 66. [PMID: 34818638 DOI: 10.1088/1361-6560/ac3d16] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Accepted: 11/24/2021] [Indexed: 11/12/2022]
Abstract
Objective. Robustness is an important aspect to consider, when developing methods for medical image analysis. This study investigated robustness properties of deep neural networks (DNNs) for a lung nodule classification problem based on CT images and proposed a solution to improve robustness.Approach. We firstly constructed a class of four DNNs with different widths, each predicting an output label (benign or malignant) for an input CT image cube containing a lung nodule. These networks were trained to achieve Area Under the Curve of 0.891-0.914 on a testing dataset. We then added to the input CT image cubes noise signals generated randomly using a realistic CT image noise model based on a noise power spectrum at 100 mAs, and monitored the DNNs output change. We definedSAR5(%) to quantify the robustness of the trained DNN model, indicating that for 5% of CT image cubes, the noise can change the prediction results with a chance of at leastSAR5(%). To understand robustness, we viewed the information processing pipeline by the DNN as a two-step process, with the first step using all but the last layers to extract representations of the input CT image cubes in a latent space, and the second step employing the last fully-connected layer as a linear classifier to determine the position of the sample representations relative to a decision plane. To improve robustness, we proposed to retrain the last layer of the DNN with a Supporting Vector Machine (SVM) hinge loss function to enforce the desired position of the decision plane.Main results.SAR5ranged in 47.0%-62.0% in different DNNs. The unrobustness behavior may be ascribed to the unfavorable placement of the decision plane in the latent representation space, which made some samples be perturbed to across the decision plane and hence susceptible to noise. The DNN-SVM model improved robustness over the DNN model and reducedSAR5by 8.8%-21.0%.Significance. This study provided insights about the potential reason for the unrobustness behavior of DNNs and the proposed DNN-SVM model improved model robustness.
Collapse
Affiliation(s)
- Yin Gao
- Innovative Technology Of Radiotherapy Computations and Hardware (iTORCH) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, United States of America
| | - Jennifer Xiong
- Innovative Technology Of Radiotherapy Computations and Hardware (iTORCH) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, United States of America
| | - Chenyang Shen
- Innovative Technology Of Radiotherapy Computations and Hardware (iTORCH) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, United States of America
| | - Xun Jia
- Innovative Technology Of Radiotherapy Computations and Hardware (iTORCH) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, United States of America
| |
Collapse
|
44
|
Improving the Quality of Care in Radiation Oncology using Artificial Intelligence. Clin Oncol (R Coll Radiol) 2021; 34:89-98. [PMID: 34887152 DOI: 10.1016/j.clon.2021.11.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 10/20/2021] [Accepted: 11/12/2021] [Indexed: 12/13/2022]
Abstract
Radiation therapy is a complex process involving multiple professionals and steps from simulation to treatment planning to delivery, and these procedures are prone to error. Additionally, the imaging and treatment delivery equipment in radiotherapy is highly complex and interconnected and represents another risk point in the quality of care. Numerous quality assurance tasks are carried out to ensure quality and to detect and prevent potential errors in the process of care. Recent developments in artificial intelligence provide potential tools to the radiation oncology community to improve the efficiency and performance of quality assurance efforts. Targets for artificial intelligence enhancement include the quality assurance of treatment plans, target and tissue structure delineation used in the plans, delivery of the plans and the radiotherapy delivery equipment itself. Here we review recent developments of artificial intelligence applications that aim to improve quality assurance processes in radiation therapy and discuss some of the challenges and limitations that require further development work to realise the potential of artificial intelligence for quality assurance.
Collapse
|
45
|
Kusunoki T, Hatanaka S, Hariu M, Kusano Y, Yoshida D, Katoh H, Shimbo M, Takahashi T. Evaluation of prediction and classification performances in different machine learning models for patient-specific quality assurance of head-and-neck VMAT plans. Med Phys 2021; 49:727-741. [PMID: 34859445 DOI: 10.1002/mp.15393] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2021] [Revised: 10/29/2021] [Accepted: 11/19/2021] [Indexed: 01/02/2023] Open
Abstract
PURPOSE The purpose of this study is to evaluate the prediction and classification performances of the gamma passing rate (GPR) for different machine learning models and to select the best model for achieving machine learning-based patient-specific quality assurance (PSQA). METHODS The measurement verification of 356 head-and-neck volumetric modulated arc therapy plans was performed using a diode array phantom (Delta4 Phantom), and GPR values at 2%/2 mm with global normalization and 3%/2 mm with local normalization were calculated. Machine learning models, including ridge regression (RIDGE), random forest (RF), support vector regression (SVR), and stacked generalization (STACKING), were used to predict the GPR. Each machine learning model was trained using 260 plans, and the prediction accuracy was evaluated using the remaining 96 plans. The prediction error between the measured and predicted GPR was evaluated. For the classification evaluation, the lower control limit for the measured GPR and lower control limit for predicted GPR (LCLp ) was defined to identify whether the GPR values represent a "pass" or a "fail." LCLp values with 99% and 99.9% confidence levels were calculated as the upper prediction limits for the GPR estimated from the linear regression between the measured and predicted GPR. RESULTS There was an overestimation trend of the low measured GPR. The maximum prediction errors for RIDGE, RF, SVR, and STACKING were 3.2%, 2.9%, 2.3%, and 2.2% at the global 2%/2 mm and 6.3%, 6.6%, 6.1%, and 5.5% at the local 3%/2 mm, respectively. In the global 2%/2 mm, the sensitivity was 100% for all the machine learning models except RIDGE when using 99% LCLp . The specificity was 76.1% for RIDGE, RF, and SVR and 66.3% for STACKING; however, the specificity decreased dramatically when 99.9% LCLp was used. In the local 3%/2 mm, however, only STACKING showed 100% sensitivity when using 99% LCLp . The decrease in the specificity using 99.9% LCLp was smaller than that in the global 2%/2 mm, and the specificity for RIDGE, RF, SVR, and STACKING was 61.3%, 61.3%, 72.0%, and 66.8%, respectively. CONCLUSIONS STACKING had better prediction accuracy for low GPR values than other machine learning models. Applying LCLp to a regression model enabled the consistent evaluation of quantitative and qualitative GPR predictions. Adjusting the confidence level of the LCLp helped improve the balance between the sensitivity and specificity. We suggest that STACKING can assist the safe and efficient operation of PSQA.
Collapse
Affiliation(s)
- Terufumi Kusunoki
- Section of Medical Physics and Engineering, Kanagawa Cancer Center, Yokohama, Japan.,Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kawagoe, Japan
| | - Shogo Hatanaka
- Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kawagoe, Japan
| | - Masatsugu Hariu
- Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kawagoe, Japan
| | - Yohsuke Kusano
- Section of Medical Physics and Engineering, Kanagawa Cancer Center, Yokohama, Japan
| | - Daisaku Yoshida
- Section of Medical Physics and Engineering, Kanagawa Cancer Center, Yokohama, Japan.,Department of Radiation Oncology, Kanagawa Cancer Center, Yokohama, Japan
| | - Hiroyuki Katoh
- Department of Radiation Oncology, Kanagawa Cancer Center, Yokohama, Japan
| | - Munefumi Shimbo
- Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kawagoe, Japan
| | - Takeo Takahashi
- Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kawagoe, Japan
| |
Collapse
|
46
|
Utsunomiya S. [3. Radiomics Analysis of Dose and Fluence Distribution (Dosiomics)]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2021; 77:1245-1249. [PMID: 34670934 DOI: 10.6009/jjrt.2021_jsrt_77.10.1245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Satoru Utsunomiya
- Department of Radiological Technology, Graduate School of Health Sciences, Niigata University
| |
Collapse
|
47
|
Dai G, Zhang X, Liu W, Li Z, Wang G, Liu Y, Xiao Q, Duan L, Li J, Song X, Li G, Bai S. Analysis of EPID Transmission Fluence Maps Using Machine Learning Models and CNN for Identifying Position Errors in the Treatment of GO Patients. Front Oncol 2021; 11:721591. [PMID: 34595115 PMCID: PMC8476908 DOI: 10.3389/fonc.2021.721591] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Accepted: 08/30/2021] [Indexed: 02/05/2023] Open
Abstract
Purpose To find a suitable method for analyzing electronic portal imaging device (EPID) transmission fluence maps for the identification of position errors in the in vivo dose monitoring of patients with Graves' ophthalmopathy (GO). Methods Position errors combining 0-, 2-, and 4-mm errors in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions in the delivery of 40 GO patient radiotherapy plans to a human head phantom were simulated and EPID transmission fluence maps were acquired. Dose difference (DD) and structural similarity (SSIM) maps were calculated to quantify changes in the fluence maps. Three types of machine learning (ML) models that utilize radiomics features of the DD maps (ML 1 models), features of the SSIM maps (ML 2 models), and features of both DD and SSIM maps (ML 3 models) as inputs were used to perform three types of position error classification, namely a binary classification of the isocenter error (type 1), three binary classifications of LR, SI, and AP direction errors (type 2), and an eight-element classification of the combined LR, SI, and AP direction errors (type 3). Convolutional neural network (CNN) was also used to classify position errors using the DD and SSIM maps as input. Results The best-performing ML 1 model was XGBoost, which achieved accuracies of 0.889, 0.755, 0.778, 0.833, and 0.532 in the type 1, type 2-LR, type 2-AP, type 2-SI, and type 3 classification, respectively. The best ML 2 model was XGBoost, which achieved accuracies of 0.856, 0.731, 0.736, 0.949, and 0.491, respectively. The best ML 3 model was linear discriminant classifier (LDC), which achieved accuracies of 0.903, 0.792, 0.870, 0.931, and 0.671, respectively. The CNN achieved classification accuracies of 0.925, 0.833, 0.875, 0.949, and 0.689, respectively. Conclusion ML models and CNN using combined DD and SSIM maps can analyze EPID transmission fluence maps to identify position errors in the treatment of GO patients. Further studies with large sample sizes are needed to improve the accuracy of CNN.
Collapse
Affiliation(s)
- Guyu Dai
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Xiangbin Zhang
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Wenjie Liu
- Machine Intelligence Laboratory, College of Computer Science, Sichuan University, Chengdu, China
| | - Zhibin Li
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Guangyu Wang
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Yaxin Liu
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Qing Xiao
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Lian Duan
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Jing Li
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Xinyu Song
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Guangjun Li
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Sen Bai
- Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| |
Collapse
|
48
|
Li B, Chen J, Guo W, Mao R, Zheng X, Cheng X, Cui T, Lou Z, Wang T, Li D, Tao H, Lei H, Ge H. Improvement Using Planomics Features on Prediction and Classification of Patient-Specific Quality Assurance Using Head and Neck Volumetric Modulated Arc Therapy Plan. Front Neurosci 2021; 15:744296. [PMID: 34658779 PMCID: PMC8517188 DOI: 10.3389/fnins.2021.744296] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Accepted: 08/17/2021] [Indexed: 11/30/2022] Open
Abstract
Purpose: This study aimed to evaluate the utility of a new plan feature (planomics feature) for predicting the results of patient-specific quality assurance using the head and neck (H&N) volumetric modulated arc therapy (VMAT) plan. Methods: One hundred and thirty-one H&N VMAT plans in our institution from 2019 to 2021 were retrospectively collected. Dosimetric verification for all plans was carried out using the portal dosimetry system integrated into the Eclipse treatment planning system based on the electronic portal imaging devices. Gamma passing rates (GPR) were analyzed using three gamma indices of 3%/3 mm, 3%/2 mm, and 2%/2 mm with a 10% dose threshold. Forty-eight conventional features affecting the dose delivery accuracy were used in the study, and 2,476 planomics features were extracted based on the radiotherapy plan file. Three prediction and classification models using conventional features (CF), planomics features (PF), and hybrid features (HF) combining two sets of features were constructed by the gradient boosting regressor (GBR) and Ridge classifier for each GPR of 3%/3 mm, 3%/2 mm, and 2%/2 mm, respectively. The absolute prediction error (APE) and the area under the curve (AUC) were adopted for assessing the performance of prediction and classification models. Results: In the GPR prediction, the average APE of the models using CF, PF, and HF was 1.3 ± 1.2%/3.6 ± 3.0%, 1.7 ± 1.5%/3.8 ± 3.5%, and 1.1 ± 1.0%/4.1 ± 3.1% for 2%/2 mm; 0.7 ± 0.6%/2.0 ± 2.0%, 1.0±1.1%/2.2 ± 1.8%, and 0.6 ± 0.6%/2.2 ± 1.9% for 3%/2 mm; and 0.4 ± 0.3%/1.2 ± 1.2%, 0.4±0.5%/1.3 ± 1.0%, and 0.3±0.3%/1.2 ± 1.1% for 3%/3 mm, respectively. In the regression prediction, three models give a similar modeling performance for predicting the GPR. The classification results were 0.67 ± 0.03/0.66 ± 0.07, 0.77 ± 0.03/0.73 ± 0.06, and 0.78 ± 0.02/0.75 ± 0.04 for 3%/3 mm, respectively. For 3%/2 mm, the AUCs of the training and testing cohorts were 0.64 ± 0.03/0.62 ± 0.07, 0.70 ± 0.03/0.67 ± 0.06, and 0.75 ± 0.03/0.71 ± 0.07, respectively, and for 2%/2 mm, the average AUCs of the training and testing cohorts were 0.72 ± 0.03/0.72 ± 0.06, 0.78 ± 0.04/0.73 ± 0.07, and 0.81 ± 0.03/0.75 ± 0.06, respectively. In the classification, the PF model has a better classification performance than the CF model. Moreover, the HF model provides the best result among the three classifications models. Conclusions: The planomics features can be used for predicting and classifying the GPR results and for improving the model performance after combining the conventional features for the GPR classification.
Collapse
Affiliation(s)
- Bing Li
- Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou, China
| | - Junying Chen
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Wei Guo
- Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou, China
| | - Ronghu Mao
- Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou, China
| | - Xiaoli Zheng
- Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou, China
| | - Xiuyan Cheng
- Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou, China
| | - Tiantian Cui
- Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou, China
| | - Zhaoyang Lou
- Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou, China
| | - Ting Wang
- Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou, China
| | - Dingjie Li
- Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou, China
| | - Hongyan Tao
- Department of Planning and Finance, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou, China
| | - Hongchang Lei
- Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou, China
| | - Hong Ge
- Department of Radiation Oncology, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou, China
| |
Collapse
|
49
|
Wakita A. [12. Application of Deep Learning in Radiotherapy Imaging]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2021; 77:835-839. [PMID: 34421072 DOI: 10.6009/jjrt.2021_jsrt_77.8.835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
50
|
Osman AFI, Maalej NM. Applications of machine and deep learning to patient-specific IMRT/VMAT quality assurance. J Appl Clin Med Phys 2021; 22:20-36. [PMID: 34343412 PMCID: PMC8425899 DOI: 10.1002/acm2.13375] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 06/20/2021] [Accepted: 07/18/2021] [Indexed: 01/10/2023] Open
Abstract
In order to deliver accurate and safe treatment to cancer patients in radiation therapy using advanced techniques such as intensity modulated radiation therapy (IMRT) and volumetric-arc radiation therapy (VMAT), patient specific quality assurance (QA) should be performed before treatment. IMRT/VMAT dose measurements in a phantom using various devices have been clinically adopted as standard method for QA. This approach allows the verification of the accuracy of the dose calculation, data transfer, and the delivery system. However, patient-specific QA procedures are expensive and require significant time and effort by the physicists. Over the past 5 years, machine learning (ML) and deep learning (DL) algorithms for predictions of IMRT/VMAT QA outcome have been investigated. Various ML and DL models have shown promising prediction accuracy and a high potential as time-efficient virtual QA tool. In this paper, we review the ML and DL based models that were developed for patient specific IMRT and VMAT QA outcome predictions from algorithmic and clinical applicability perspectives. We focus on comparing the algorithms, the dataset sizes, the input parameters and features, the QA outcome prediction approaches, the validation, the performance, the clinical applicability, and the potential clinical impact. In addition, we discuss the present challenges as well as the future directions in the implementation of these models. To the best of our knowledge, this is the first review on the application of ML and DL based models in IMRT/VMAT QA predictions.
Collapse
Affiliation(s)
| | - Nabil M Maalej
- Department of Physics, Khalifa University, Abu Dhabi, UAE
| |
Collapse
|