Ganji SK, An Z, Tiwari V, Chang Y, Patel TR, Maher EA, Choi C. Optimization of spectrally selective 180° radiofrequency pulse timings in J-difference editing (MEGA) of lactate. Magn Reson Med 2022; 87:1150-1164. [PMID: 34657302 PMCID: PMC8776585 DOI: 10.1002/mrm.29051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 09/24/2021] [Accepted: 09/29/2021] [Indexed: 11/08/2022]
Abstract
PURPOSE J-Difference editing (MEGA) provides an effective spectroscopic means of selectively measuring low-concentration metabolites having weakly coupled spins. The fractional inphase and antiphase coherences are determined by the radiofrequency (RF) pulses and inter-RF pulse intervals of the sequence. We examined the timings of the spectrally selective editing 180° pulses (E180) in MEGA-PRESS to maximize the edited signal amplitude in lactate at 3T. METHODS The time evolution of the lactate spin coherences was analytically and numerically calculated for non-volume localized and single-voxel localized MEGA sequences. Single-voxel localized MEGA-PRESS simulations and phantom experiments were conducted for echo time (TE) 60-160 ms and for all possible integer-millisecond timings of the E180 pulses. Optimized E180 timings of 144, 103, and 109 ms TEs, tailored with simulation and phantom data, were tested in brain tumor patients in vivo. Lactate signals, broadened to singlet linewidths (~6 Hz), were compared between simulation, phantom, and in vivo data. RESULTS Theoretical and experimental data indicated consistently that the MEGA-edited signal amplitude and width are sensitive to the E180 timings. In volume-localized MEGA, the lactate peak amplitudes in E180-on and difference spectra were maximized at specific E180 timings for individual TEs, largely due to the chemical-shift displacement effects. The E180 timings for maximum lactate peak amplitude were different from those of maximum inphase coherence in in vivo linewidth situations. CONCLUSION In in vivo MEGA editing, the E180 pulse timings can be effectively used for manipulating the inphase and antiphase coherences and increasing the edited signal amplitude, following TE optimization.
Collapse
Affiliation(s)
- Sandeep K. Ganji
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA,Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas,Philips Healthcare, Andover, Massachusetts, USA
| | - Zhongxu An
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Vivek Tiwari
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Yongmin Chang
- Department of Molecular Medicine, School of Medicine, Kyungpook National University, Daegu, Republic of Korea
| | - Toral R. Patel
- Department of Neurological Surgery, University of Texas Southwestern Medical Center, Dallas, Texas, USA,Department of Neurology and Neurotherapeutics, University of Texas Southwestern Medical Center, Dallas, Texas, USA,Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Elizabeth A. Maher
- Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas, USA,Department of Neurology and Neurotherapeutics, University of Texas Southwestern Medical Center, Dallas, Texas, USA,Harold C. Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA,Annette G. Strauss Center for Neuro-Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Changho Choi
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA,Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas,Harold C. Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| |
Collapse
|
2
|
Sun H, You Y, Xue B, Xiao S, Lu Y, Ma H, Hou Y, Yu B, Pan X. Effect of DRD4 Receptor -616 C/G Polymorphism on Thalamic GABA Levels in Pediatric Patients With Primary Nocturnal Enuresis. J Magn Reson Imaging 2021; 54:1857-1864. [PMID: 34121249 DOI: 10.1002/jmri.27782] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 05/27/2021] [Accepted: 05/28/2021] [Indexed: 12/18/2022] Open
Abstract
BACKGROUND The single nucleotide polymorphism (SNP) of dopamine D4 receptor (DRD4) promoter (-616; rs747302) is associated with abnormalities of the thalamus in children suffering from primary nocturnal enuresis (PNE). PURPOSE To investigate the effect of DRD4 -616 C/G SNP on thalamic gamma-aminobutyric acid (GABA) levels in PNE children. STUDY TYPE Prospective, observational. SUBJECTS One hundred and seventy-six children with PNE and 161 healthy control children. FIELD STRENGTH/SEQUENCE 3 T, three-dimensional T1-weighted turbo field echo sequence and MEscher-Garwood Point RESolved Spectroscopy (MEGA-PRESS) MRS sequence. ASSESSMENT The MEGA-PRESS MRS sequence was used to measure thalamic GABA spectra. The thalamic GABA+ level was calculated using the Gannet 3.0 software package for each participant. A questionnaire was used to determine arousal from sleep (AS) scores. STATISTICAL TESTS Comparisons of the AS scores and thalamic GABA+ levels were performed using the Mann-Whitney U test between C-allele carriers and GG homozygotes in the PNE and control groups. Spearman correlation analysis was performed to determine the association between AS scores and thalamic GABA levels in PNE children. RESULTS Thalamic GABA levels in the PNE group were significantly higher than those in the healthy control group (0.178 (0.169-0.186) vs. 0.154 (0.146-0.164), Z = 8.526, Pcorrected < 0.001). The GABA levels in C-allele carriers were significantly higher than those in GG homozygotes in both the PNE and control groups (0.184 (0.181-0.193) vs. 0.170 (0.165-0.177), Z = 8.683, Pcorrected < 0.001; 0.166 (0.156-0.170) vs. 0.147 (0.141-0.152), Z = 9.445, Pcorrected < 0.001). GABA levels in the thalamus were also significantly and positively correlated with AS scores in C-allele carriers in the PNE group (r = 0.747, P < 0.05). DATA CONCLUSION DRD4 -616 C allele may be associated with increased thalamic GABA+ levels, especially in C-allele carrying PNE children. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY STAGE: 3.
Collapse
Affiliation(s)
- Hongbin Sun
- Department of Radiology, The Fourth Affiliated Hospital of China Medical University, Shenyang, China
| | - Yi You
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, China
| | - Bing Xue
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, China
| | - Shanshan Xiao
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, China
| | - Yao Lu
- Center of the Laboratory Technology and Experimental Medicine, China Medical University, Shenyang, China
| | - Hongwei Ma
- Department of Developmental Pediatrics, Shengjing Hospital of China Medical University, Shenyang, China
| | - Yang Hou
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, China
| | - Bing Yu
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, China
| | - Xin Pan
- Department of Radiology, The Fourth Affiliated Hospital of China Medical University, Shenyang, China
| |
Collapse
|
3
|
Tiwari V, An Z, Wang Y, Choi C. Distinction of the GABA 2.29 ppm resonance using triple refocusing at 3 T in vivo. Magn Reson Med 2018; 80:1307-1319. [PMID: 29446149 DOI: 10.1002/mrm.27142] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2017] [Revised: 01/29/2018] [Accepted: 01/30/2018] [Indexed: 12/21/2022]
Abstract
PURPOSE To develop 1 H MR spectroscopy that provides distinction of γ-aminobutyric acid (GABA) signal at 3 T in vivo. METHODS Triple-refocusing was tailored at 3 T, with numerical simulations and phantom validation, for distinction of the GABA 2.29-ppm resonance from the neighboring glutamate resonance. The optimization was performed on the inter-RF pulse time delays and the duration and carrier frequency of a non-slice-selective RF pulse. The optimized triple refocusing was tested in multiple regions in 6 healthy subjects, including hippocampus. The in vivo spectra were analyzed with the LCModel using in-house basis spectra. After normalization of the metabolite signal estimates to water, the metabolite concentrations were quantified with reference to medial-occipital creatine at 8 mM. RESULTS A triple-refocusing scheme with optimized inter-RF pulse time delays (TE = 74 ms) was obtained for GABA detection. With optimized duration (14 ms) and carrier frequency (4.5 ppm) of the non-slice-selective RF pulse, the triple refocusing gave rise to distinction between the GABA 2.29-ppm and glutamate 2.35-ppm signals. The GABA 2.29-ppm signal was clearly discernible in spectra in vivo (voxel size 4 to 12 mL; scan times 4.3 to 17 minutes). With a total of 24 spectra from 6 gray or white matter-dominant regions, the GABA concentration was measured to be 0.62 to 1.15 mM (Cramer-Rao lower bound of 8 to 14%), and the glutamate level 5.8 to 11.2 mM (Cramer-Rao lower bound of 3 to 6%). CONCLUSION The optimized triple refocusing provided distinction between GABA and glutamate signals and permitted direct codetection of these metabolites in the human brain at 3 T in vivo.
Collapse
Affiliation(s)
- Vivek Tiwari
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Zhongxu An
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Yiming Wang
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Changho Choi
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas
| |
Collapse
|
4
|
Dobberthien BJ, Tessier AG, Yahya A. Improved resolution of glutamate, glutamine and γ-aminobutyric acid with optimized point-resolved spectroscopy sequence timings for their simultaneous quantification at 9.4 T. NMR IN BIOMEDICINE 2018; 31:e3851. [PMID: 29105187 DOI: 10.1002/nbm.3851] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2017] [Revised: 09/15/2017] [Accepted: 09/25/2017] [Indexed: 06/07/2023]
Abstract
Glutamine (Gln), glutamate (Glu) and γ-aminobutyric acid (GABA) are relevant brain metabolites that can be measured with magnetic resonance spectroscopy (MRS). This work optimizes the point-resolved spectroscopy (PRESS) sequence echo times, TE1 and TE2 , for improved simultaneous quantification of the three metabolites at 9.4 T. Quantification was based on the proton resonances of Gln, Glu and GABA at ≈2.45, ≈2.35 and ≈2.28 ppm, respectively. Glu exhibits overlap with both Gln and GABA; in addition, the Gln peak is contaminated by signal from the strongly coupled protons of N-acetylaspartate (NAA), which resonate at about 2.49 ppm. J-coupling evolution of the protons was characterized numerically and verified experimentally. A {TE1 , TE2 } combination of {106 ms, 16 ms} minimized the NAA signal in the Gln spectral region, whilst retaining Gln, Glu and GABA peaks. The efficacy of the technique was verified on phantom solutions and on rat brain in vivo. LCModel was employed to analyze the in vivo spectra. The average T2 -corrected Gln, Glu and GABA concentrations were found to be 3.39, 11.43 and 2.20 mM, respectively, assuming a total creatine concentration of 8.5 mM. LCModel Cramér-Rao lower bounds (CRLBs) for Gln, Glu and GABA were in the ranges 14-17%, 4-6% and 16-19%, respectively. The optimal TE resulted in concentrations for Gln and GABA that agreed more closely with literature concentrations compared with concentrations obtained from short-TE spectra acquired with a {TE1 , TE2 } combination of {12 ms, 9 ms}. LCModel estimations were also evaluated with short-TE PRESS and with the optimized long TE of {106 ms, 16 ms}, using phantom solutions of known metabolite concentrations. It was shown that concentrations estimated with LCModel can be inaccurate when combined with short-TE PRESS, where there is peak overlap, even when low (<20%) CRLBs are reported.
Collapse
Affiliation(s)
| | - Anthony G Tessier
- Department of Oncology, University of Alberta, Edmonton, AB, Canada
- Department of Medical Physics, Cross Cancer Institute, Edmonton, AB, Canada
| | - Atiyah Yahya
- Department of Oncology, University of Alberta, Edmonton, AB, Canada
- Department of Medical Physics, Cross Cancer Institute, Edmonton, AB, Canada
| |
Collapse
|
5
|
Gambarota G. Optimization of metabolite detection by quantum mechanics simulations in magnetic resonance spectroscopy. Anal Biochem 2017; 529:65-78. [DOI: 10.1016/j.ab.2016.08.019] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2016] [Revised: 07/31/2016] [Accepted: 08/22/2016] [Indexed: 10/21/2022]
|
6
|
Harris AD, Saleh MG, Edden RAE. Edited 1 H magnetic resonance spectroscopy in vivo: Methods and metabolites. Magn Reson Med 2017; 77:1377-1389. [PMID: 28150876 PMCID: PMC5352552 DOI: 10.1002/mrm.26619] [Citation(s) in RCA: 118] [Impact Index Per Article: 16.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2016] [Revised: 12/30/2016] [Accepted: 12/30/2016] [Indexed: 12/13/2022]
Abstract
The Proton magnetic resonance (1 H-MRS) spectrum contains information about the concentration of tissue metabolites within a predefined region of interest (a voxel). The conventional spectrum in some cases obscures information about less abundant metabolites due to limited separation and complex splitting of the metabolite peaks. One method to detect these metabolites is to reduce the complexity of the spectrum using editing. This review provides an overview of the one-dimensional editing methods available to interrogate these obscured metabolite peaks. These methods include sequence optimizations, echo-time averaging, J-difference editing methods (single BASING, dual BASING, and MEGA-PRESS), constant-time PRESS, and multiple quantum filtering. It then provides an overview of the brain metabolites whose detection can benefit from one or more of these editing approaches, including ascorbic acid, γ-aminobutyric acid, lactate, aspartate, N-acetyl aspartyl glutamate, 2-hydroxyglutarate, glutathione, glutamate, glycine, and serine. Magn Reson Med 77:1377-1389, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Ashley D Harris
- Department of Radiology, University of Calgary, Calgary, AB T2N 1N4, Canada
- Child and Adolescent Imaging Research (CAIR) Program, Alberta Children's Hospital Research Institute, University of Calgary, Calgary, AB T3B 6A9, Canada
- Hotchkiss Brain Institute, University of Calgary, Calgary, AB T2N 1N4, Canada
| | - Muhammad G Saleh
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA
- F.M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD 21205, USA
| | - Richard A E Edden
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA
- F.M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD 21205, USA
| |
Collapse
|
7
|
Ganji SK, An Z, Banerjee A, Madan A, Hulsey KM, Choi C. Measurement of regional variation of GABA in the human brain by optimized point-resolved spectroscopy at 7 T in vivo. NMR IN BIOMEDICINE 2014; 27:1167-75. [PMID: 25088346 PMCID: PMC4182098 DOI: 10.1002/nbm.3170] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2014] [Revised: 06/12/2014] [Accepted: 07/01/2014] [Indexed: 05/15/2023]
Abstract
The (1)H resonances of γ-aminobutyric acid (GABA) in the human brain in vivo are extensively overlapped with the neighboring abundant resonances of other metabolites and remain indiscernible in short-TE MRS at 7 T. Here we report that the GABA resonance at 2.28 ppm can be fully resolved by means of echo time optimization of a point-resolved spectroscopy (PRESS) scheme. Following numerical simulations and phantom validation, the subecho times of PRESS were optimized at (TE, TE2) = (31, 61) ms for detection of GABA, glutamate (Glu), glutamine (Gln), and glutathione (GSH). The in vivo feasibility of the method was tested in several brain regions in nine healthy subjects. Spectra were acquired from the medial prefrontal, left frontal, medial occipital, and left occipital brain and analyzed with LCModel. Following the gray and white matter (GM and WM) segmentation of T1 -weighted images, linear regression of metabolite estimates was performed against the fractional GM contents. The GABA concentration was estimated to be about seven times higher in GM than in WM. GABA was overall higher in frontal than in occipital brain. Glu was about twice as high in GM as in WM in both frontal and occipital brain. Gln was significantly different between frontal GM and WM while being similar between occipital GM and WM. GSH did not show significant dependence on tissue content. The signals from N-acetylaspartylglutamate were clearly resolved, giving the concentration more than 10 times higher in WM than in GM. Our data indicate that the PRESS TE = 92 ms method provides an effective means for measuring GABA and several challenging J-coupled spin metabolites in human brain at 7 T.
Collapse
Affiliation(s)
- Sandeep K. Ganji
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Zhongxu An
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Abhishek Banerjee
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Akshay Madan
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Keith M. Hulsey
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Changho Choi
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Correspondence to: Changho Choi, PhD, Advanced Imaging Research Center, 5323 Harry Hines Blvd., Dallas, Texas, USA 75390,
| |
Collapse
|
8
|
Rae CD. A Guide to the Metabolic Pathways and Function of Metabolites Observed in Human Brain 1H Magnetic Resonance Spectra. Neurochem Res 2013; 39:1-36. [PMID: 24258018 DOI: 10.1007/s11064-013-1199-5] [Citation(s) in RCA: 327] [Impact Index Per Article: 29.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2013] [Revised: 11/08/2013] [Accepted: 11/11/2013] [Indexed: 12/20/2022]
|
9
|
Nasrallah FA, Balcar VJ, Rae CD. Activity-dependent γ-aminobutyric acid release controls brain cortical tissue slice metabolism. J Neurosci Res 2011; 89:1935-45. [DOI: 10.1002/jnr.22649] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2010] [Revised: 02/15/2011] [Accepted: 03/01/2011] [Indexed: 12/16/2022]
|
10
|
Yang S, Hu J, Kou Z, Yang Y. Spectral simplification for resolved glutamate and glutamine measurement using a standard STEAM sequence with optimized timing parameters at 3, 4, 4.7, 7, and 9.4T. Magn Reson Med 2008; 59:236-44. [PMID: 18228589 DOI: 10.1002/mrm.21463] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The C4 multiplet proton resonances of glutamate (Glu) around 2.35 ppm and glutamine (Gln) around 2.45 ppm usually overlap in MR spectra, particularly at low- and mid-field strengths (1.5-4.7T). A spectral simplification approach is introduced that provides unobstructed Glu and Gln measurement using a standard STEAM localization sequence with optimized interpulse timings. The underlying idea is to exploit the dependence of response of a coupled spin system on the echo time (TE) and mixing time (TM) to find an optimum timing set (TE, TM), at which the outer-wings of C4 "pseudo-triplet" proton resonances of Glu and Gln are significantly suppressed while the central peaks are maintained. The spectral overlap is thus resolved as the overlap exists exclusively at the outer-wings and the central peaks are readily separated due to the approximate 0.1-ppm difference in chemical shift. Density matrix simulation for Glu, Gln, and other overlapping metabolites at 2.3-2.5 ppm was conducted to predict the optimum timing sets. The simulated, phantom, and in vivo results demonstrated that the C4 multiplet proton resonances of Glu and Gln can be resolved for unobstructed detection at 3T, 4T, and 4.7T. For simplicity, only simulated data are illustrated at 7T and 9.4T.
Collapse
Affiliation(s)
- Shaolin Yang
- Neuroimaging Research Branch, National Institute on Drug Abuse, National Institutes of Health, 5500 Nathan Shock Boulevard, Baltimore, MD 21224, USA
| | | | | | | |
Collapse
|
11
|
McGrath BM, McKay R, Dave S, Seres P, Weljie AM, Slupsky CM, Hanstock CC, Greenshaw AJ, Silverstone PH. Acute dextro-amphetamine administration does not alter brain myo-inositol levels in humans and animals: MRS investigations at 3 and 18.8 T. Neurosci Res 2008; 61:351-9. [PMID: 18508145 DOI: 10.1016/j.neures.2008.04.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2007] [Revised: 04/05/2008] [Accepted: 04/09/2008] [Indexed: 11/24/2022]
Abstract
The pathophysiological underpinnings of bipolar disorder are not fully understood. However, they may be due in part to changes in the phosphatidylinositol second messenger system (PI-cycle) generally, or changes in myo-inositol concentrations more specifically. Dextro-amphetamine has been used as a model for mania in several human studies as it causes similar subjective and physiological symptoms. We wanted to determine if dextro-amphetamine altered myo-inositol concentrations in vivo as it would clearly define a mechanism linking putative changes in the PI-cycle to the subjective psychological changes seen with dextro-amphetamine administration. Fifteen healthy human volunteers received a baseline scan, followed by second scan 75 min after receiving a 25 mg oral dose of dextro-amphetamine. Stimulated echo proton magnetic resonance spectroscopy (MRS) scans were preformed at 3.0 Tesla (T) in the dorsal medial prefrontal cortex (DMPFC). Metabolite data were adjusted for tissue composition and analyzed using LCModel. Twelve adult male rats were treated acutely with a 5-mg/kg intraperitoneal dose of dextro-amphetamine. After 1 h rats were decapitated and the brains were rapidly removed and frozen until dissection. Rat brains were dissected into frontal, temporal, and occipital cortical areas, as well as hippocampus. Tissue was analyzed using a Varian 18.8 T spectrometer. Metabolites were identified and quantified using Chenomx Profiler software. The main finding in the present study was that myo-inositol concentrations in the DMPFC of human volunteers and in the four rat brain regions were not altered by acute dextro-amphetamine. While it remains possible that the PI-cycle may be involved in the pathophysiology of bipolar disorder, it is not likely that the subjective and physiological of dextro-amphetamine are mediated, directly or indirectly, via alternations in myo-inositol concentrations.
Collapse
Affiliation(s)
- Brent M McGrath
- Department of Psychiatry, University of Alberta, Edmonton, Alberta, Canada T6G 2B7.
| | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Lymer K, Haga K, Marshall I, Sailasuta N, Wardlaw J. Reproducibility of GABA measurements using 2D J-resolved magnetic resonance spectroscopy. Magn Reson Imaging 2007; 25:634-40. [PMID: 17540274 DOI: 10.1016/j.mri.2006.10.010] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2006] [Accepted: 10/01/2006] [Indexed: 10/23/2022]
Abstract
We determined the reproducibility of GABA (gamma-aminobutyric acid) measurements using 2D J-resolved magnetic resonance spectroscopy (MRS) on a clinical 1.5-T MR imaging scanner. Two-dimensional J-resolved spectra were acquired in vitro across five GABA concentrations using a volume head coil and a 5-in. surface coil. Additional spectra using a sixth GABA phantom with a very low concentration and from a healthy volunteer were recorded in the 5-in. surface coil only. In each case, the 3.01-ppm GABA resonance was quantified; for comparison, the peak integrals of choline (3.2 ppm) and creatine (3.03 ppm) were recorded. At a physiological concentration (1.2 mM), in vitro GABA measurement was significantly more reproducible in the surface coil than in the volume coil (P=.005), with coefficients of variation (CVs) being less than 16% with the surface coil and up to 68% with the volume head coil. At the smallest concentration of in vivo GABA reported using other spectroscopy techniques (0.8 mM) and detected only using the surface coil, the CV for GABA was 23% and was less than 10% for choline and creatine, which compare favorably with results from published studies. In vivo, the CV for GABA measurement was 26%, suggesting that 2D J-resolved MRS would be suitable for detecting physiological changes in GABA, similar to those reported using other methods.
Collapse
Affiliation(s)
- Katherine Lymer
- Division of Psychiatry, School of Molecular and Clinical Medicine, University of Edinburgh, Royal Edinburgh Hospital, Morningside Park, Edinburgh, UK.
| | | | | | | | | |
Collapse
|
13
|
Hu J, Yang S, Xuan Y, Jiang Q, Yang Y, Haacke EM. Simultaneous detection of resolved glutamate, glutamine, and gamma-aminobutyric acid at 4 T. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2007; 185:204-13. [PMID: 17223596 PMCID: PMC1995429 DOI: 10.1016/j.jmr.2006.12.010] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2006] [Revised: 12/12/2006] [Accepted: 12/13/2006] [Indexed: 05/13/2023]
Abstract
A new approach is introduced to simultaneously detect resolved glutamate (Glu), glutamine (Gln), and gamma-aminobutyric acid (GABA) using a standard STEAM localization pulse sequence with the optimized sequence timing parameters. This approach exploits the dependence of the STEAM spectra of the strongly coupled spin systems of Glu, Gln, and GABA on the echo time TE and the mixing time TM at 4 T to find an optimized sequence parameter set, i.e., {TE, TM}, where the outer-wings of the Glu C4 multiplet resonances around 2.35 ppm, the Gln C4 multiplet resonances around 2.45 ppm, and the GABA C2 multiplet resonance around 2.28 ppm are significantly suppressed and the three resonances become virtual singlets simultaneously and thus resolved. Spectral simulation and optimization were conducted to find the optimized sequence parameters, and phantom and in vivo experiments (on normal human brains, one patient with traumatic brain injury, and one patient with brain tumor) were carried out for verification. The results have demonstrated that the Gln, Glu, and GABA signals at 2.2-2.5 ppm can be well resolved using a standard STEAM sequence with the optimized sequence timing parameters around {82 ms,48 ms} at 4 T, while the other main metabolites, such as N-acetyl aspartate (NAA), choline (tCho), and creatine (tCr), are still preserved in the same spectrum. The technique can be easily implemented and should prove to be a useful tool for the basic and clinical studies associated with metabolism of Glu, Gln, and/or GABA.
Collapse
Affiliation(s)
- Jiani Hu
- Department of Radiology, Wayne State University, and Department of Neurology, Henry Ford Hospital, Detroit, MI 48201, USA.
| | | | | | | | | | | |
Collapse
|
14
|
Di Costanzo A, Trojsi F, Tosetti M, Schirmer T, Lechner SM, Popolizio T, Scarabino T. Proton MR spectroscopy of the brain at 3 T: an update. Eur Radiol 2007; 17:1651-62. [PMID: 17235536 DOI: 10.1007/s00330-006-0546-1] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2006] [Revised: 11/07/2006] [Accepted: 11/14/2006] [Indexed: 01/20/2023]
Abstract
Proton magnetic resonance spectroscopy ((1)H-MRS) provides specific metabolic information not otherwise observable by any other imaging method. (1)H-MRS of the brain at 3 T is a new tool in the modern neuroradiological armamentarium whose main advantages, with respect to the well-established and technologically advanced 1.5-T (1)H-MRS, include a higher signal-to-noise ratio, with a consequent increase in spatial and temporal resolutions, and better spectral resolution. These advantages allow the acquisition of higher quality and more easily quantifiable spectra in smaller voxels and/or in shorter times, and increase the sensitivity in metabolite detection. However, these advantages may be hampered by intrinsic field-dependent technical issues, such as decreased T(2) signal, chemical shift dispersion errors, J-modulation anomalies, increased magnetic susceptibility, eddy current artifacts, challenges in designing and obtaining appropriate radiofrequency coils, magnetic field instability and safety hazards. All these limitations have been tackled by manufacturers and researchers and have received one or more solutions. Furthermore, advanced (1)H-MRS techniques, such as specific spectral editing, fast (1)H-MRS imaging and diffusion tensor (1)H-MRS imaging, have been successfully implemented at 3 T. However, easier and more robust implementations of these techniques are still needed before they can become more widely used and undertake most of the clinical and research (1)H-MRS applications.
Collapse
|
15
|
Choi IY, Lee SP, Merkle H, Shen J. In vivo detection of gray and white matter differences in GABA concentration in the human brain. Neuroimage 2006; 33:85-93. [PMID: 16884929 DOI: 10.1016/j.neuroimage.2006.06.016] [Citation(s) in RCA: 68] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2006] [Revised: 05/26/2006] [Accepted: 06/18/2006] [Indexed: 12/11/2022] Open
Abstract
A novel selective multiple quantum filtering-based chemical shift imaging method was developed for acquiring GABA images in the human brain at 3 T. This method allows a concomitant acquisition of an interleaved total creatine image with the same spatial resolution. Using T(1)-based image segmentation and a nonlinear least square regression analysis of GABA-to-total creatine concentration ratios in frontal and parietal lobes of healthy adult volunteers as a function of the tissue gray matter fraction, the mean GABA concentration in gray and white matter was determined to be 1.30+/-0.36 micromol/g and 0.16+/-0.16 micromol/g (mean+/-SD, n=13), respectively. It is expected that this method will become a useful tool for studying GABAergic function in the human brain in vivo.
Collapse
Affiliation(s)
- In-Young Choi
- The Nathan Kline Institute, Medical Physics, Orangeburg, NY 10962, USA.
| | | | | | | |
Collapse
|
16
|
Abstract
Magnetic resonance spectroscopy (MRS) has been used for more than two decades to interrogate metabolite distributions in living cells and tissues. Techniques have been developed that allow multiple spectra to be obtained simultaneously with individual volume elements as small as 1 uL of tissue (i.e., 1 x 1 x 1 mm(3)). The most common modern applications of in vivo MRS use endogenous signals from (1)H, (31)P, or (23)Na. Important contributions have also been made using exogenous compounds containing (19)F, (13)C, or (17)O. MRS has been used to investigate cardiac and skeletal muscle energetics, neurobiology, and cancer. This review focuses on the latter applications, with specific reference to the measurement of tissue choline, which has proven to be a tumor biomarker that is significantly affected by anticancer therapies.
Collapse
Affiliation(s)
- Robert J Gillies
- Arizona Cancer Center, 1515 Campbell Avenue, Tucson, AZ 85724-5024, USA.
| | | |
Collapse
|
17
|
Choi IY, Lee SP, Shen J. Selective homonuclear Hartmann-Hahn transfer method for in vivo spectral editing in the human brain. Magn Reson Med 2005; 53:503-10. [PMID: 15723418 DOI: 10.1002/mrm.20381] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
A novel selective homonuclear Hartmann-Hahn transfer method for in vivo spectral editing is proposed and applied to measurements of gamma-aminobutyric acid (GABA) in the human brain at 3 T. The proposed method utilizes a new concept for in vivo spectral editing, the spectral selectivity of which is not based on a conventional editing pulse but based on the stringent requirement of the doubly selective Hartmann-Hahn match. The sensitivity and spectral selectivity of GABA detection achieved by this doubly selective Hartmann-Hahn match scheme was superior to that achievable by conventional in vivo spectral editing techniques providing both sensitivity enhancement and excellent suppression of overlapping resonances in a single shot. Since double-quantum filtering gradients were not employed, singlets such as the NAA methyl group at 2.02 ppm and the creatine methylene group at 3.92 ppm were detected simultaneously. These singlets may serve as navigators for the spectral phase of GABA and for frequency shifts during measurements. The estimated concentration of GABA in the frontoparietal region of the human brain in vivo was 0.7 +/- 0.2 mumol/g (mean +/- SD, n = 12).
Collapse
Affiliation(s)
- In-Young Choi
- Medical Physics, Nathan Kline Institute, 140 Old Orangeburg Road, Orangeburg, NY 10962, USA.
| | | | | |
Collapse
|
18
|
Coupland NJ, Ogilvie CJ, Hegadoren KM, Seres P, Hanstock CC, Allen PS. Decreased prefrontal Myo-inositol in major depressive disorder. Biol Psychiatry 2005; 57:1526-34. [PMID: 15953489 DOI: 10.1016/j.biopsych.2005.02.027] [Citation(s) in RCA: 127] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2004] [Revised: 02/09/2005] [Accepted: 02/18/2005] [Indexed: 11/23/2022]
Abstract
BACKGROUND Postmortem studies have shown robust prefrontal cortex glial losses and more subtle neuronal changes in major depressive disorder (MDD). Earlier proton magnetic resonance spectroscopy (1H-MRS) studies of the glial marker myo-inositol in MDD were subject to potential confounds. The primary hypothesis of this study was that MDD patients would show reduced prefrontal/anterior cingulate cortex levels of myo-inositol. METHODS Thirteen nonmedicated moderate-severe MDD patients and 13 matched control subjects were studied (six male, seven female per group). Proton magnetic resonance spectroscopy stimulated echo acquisition mode spectra (3.0 T; echo time=168 msec; mixing time=28 msec; repetition time=3000 msec) were obtained from prefrontal/anterior cingulate cortex. Metabolite data were adjusted for tissue composition. RESULTS Patients with MDD showed significantly lower myo-inositol/creatine ratios (.94+/-.23) than control subjects (1.32+/-.37) [F(1,23)=6.9; p=.016]. CONCLUSIONS These data suggest a reduction of myo-inositol in prefrontal/anterior cingulate cortex in MDD, which could be a consequence of glial loss or altered glial metabolism. Additional in vivo studies of glial markers could add to the understanding of the pathophysiology of MDD.
Collapse
Affiliation(s)
- Nick J Coupland
- Department of Psychiatry, University of Alberta, Edmonton, Alberta, Canada.
| | | | | | | | | | | |
Collapse
|
19
|
Abstract
Neuroimaging has important applications in the diagnosis and treatment of patients with seizures and epilepsy. Having replaced computed tomography (CT) in many situations, MRI is the preferred imaging technique for patients with epilepsy. Advances in radionuclide-based techniques such as single-photon emission CT/positron emission tomography and electromagnetic source imaging with magnetoencephalography are providing new insights into the pathophysiology of epilepsy. In addition, techniques such as magnetic resonance spectroscopy are beginning to impact treatment. In this review, I discuss how these techniques are used in clinical practice but more importantly, how imaging findings play an increasing role in neurotherapeutics.
Collapse
Affiliation(s)
- Ruben I Kuzniecky
- New York University Epilepsy Center, Department of Neurology, New York University School of Medicine, New York, New York 10016, USA
| |
Collapse
|
20
|
Abstract
1H and 31P spectroscopy detects relevant metabolite changes in patients with TLE. Numerous studies confirm reduction in NAA and in the ratio of PCr/Pi. In his 1999 review, Kuzniecky concluded that proton MRS, using single-voxel or chemical shift imaging, lateralizes temporal lobe epilepsy in 65% to 96% of cases, with bilateral changes seen in 35% to 45% of cases, whereas phosphorus MRS shows a lateralizing PCr/Pi ratio in 65% to 75% of the TLE patients. There are indications that these changes are reversible with seizure treatment. Improvements in MRS technology, such as the ability to calculate absolute concentrations, to account for differences be-tween gray and white matter and to achieve better spectral resolution by use of a higher magnetic field strength, will now allow more extensive use of this technique for patients with epilepsy.
Collapse
Affiliation(s)
- Ruben Kuzniecky
- NYU Comprehensive Epilepsy Center, New York University School of Medicine, 403 East 34th Street, New York, NY 10016, USA.
| |
Collapse
|
21
|
Shen J, Yang J, Choi IY, Li SS, Chen Z. A new strategy for in vivo spectral editing. Application to GABA editing using selective homonuclear polarization transfer spectroscopy. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2004; 170:290-298. [PMID: 15388093 DOI: 10.1016/j.jmr.2004.05.022] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2004] [Revised: 05/05/2004] [Indexed: 05/24/2023]
Abstract
A novel single-shot in vivo spectral editing method is proposed in which the signal to be detected, is regenerated anew from the thermal equilibrium magnetization of a source to which it is J-coupled. The thermal equilibrium magnetization of the signal to be detected together with those of overlapping signals are suppressed by single-shot gradient dephasing prior to the signal regeneration process. Application of this new strategy to in vivo GABA editing using selective homonuclear polarization transfer allows complete suppression of overlapping creatine and glutathione while detecting the GABA-4 methylene resonance at 3.02 ppm with an editing yield similar to that of conventional editing methods. The NAA methyl group at 2.02 ppm was simultaneously detected and can be used as an internal navigator echo for correcting the zero order phase and frequency shifts and as an internal reference for concentration. This new method has been demonstrated for robust in vivo GABA editing in the rat brain and for study of GABA synthesis after acute vigabatrin administration.
Collapse
Affiliation(s)
- Jun Shen
- Molecular Imaging Branch, National Institute of Mental Health, Building 10, Room 2D51A, 9000 Rockville Pike, Bethesda, MD 20892-1527, USA.
| | | | | | | | | |
Collapse
|
22
|
Schubert F, Gallinat J, Seifert F, Rinneberg H. Glutamate concentrations in human brain using single voxel proton magnetic resonance spectroscopy at 3 Tesla. Neuroimage 2004; 21:1762-71. [PMID: 15050596 DOI: 10.1016/j.neuroimage.2003.11.014] [Citation(s) in RCA: 204] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2003] [Revised: 11/03/2003] [Accepted: 11/04/2003] [Indexed: 10/26/2022] Open
Abstract
A method for quantitative determination of the glutamate (Glu) concentration in human brain using PRESS-based single voxel MR spectroscopy (MRS) at 3 T has been developed and validated by repeatedly analyzing voxels comprising the anterior cingulate cortex (acc) and the left hippocampus (hc) in 40 healthy volunteer brains. At an optimum echo time of 80 ms, the C4 resonance of Glu appears well resolved and separated from major interferents, that is, glutamine and N-acetylaspartate. As a complementary method, a multiple quantum coherence filter sequence for Glu was employed. For quantification of Glu and the principal MRS-visible metabolites as well as for an estimate of the glutamine level, analysis of both types of in vivo spectra was carried out by a time domain-frequency domain method involving prior knowledge obtained from phantom spectra. Using PRESS, coefficients of variation (CV) for Glu concentration were of the order of 10%. When the concentrations were corrected by individual cerebrospinal fluid fractions obtained by segmentation using spm, CVs tended to increase and the correlation coefficients for the two MRS sessions tended to decrease, indicating that this type of correction adds uncertainty to the data. The concentrations of Glu in the two voxels studied were found to be significantly different (11.6 mmol/l in acc, 10.9 mmol/l in hc, P = 0.023) and decrease with age (P < 0.04). These concentrations agreed well with those determined using the quantum coherence filter method although the uncertainty of the latter limits reliable analysis.
Collapse
Affiliation(s)
- Florian Schubert
- Laboratory of Biomedical Optics and NMR-Measuring Techniques, Division of Medical Physics and Metrological Information Technology, D-10587 Berlin, Germany.
| | | | | | | |
Collapse
|
23
|
Kim H, Wild JM, Allen PS. Strategy for the spectral filtering of myo-inositol and other strongly coupled spins. Magn Reson Med 2004; 51:263-72. [PMID: 14755650 DOI: 10.1002/mrm.10697] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A multiple quantum filter strategy is presented for spectrally discriminating metabolites with strongly coupled spins from those whose spins are either uncoupled or weakly coupled. The strategy also includes a means for selectively suppressing the background multiplets of metabolites that also have strongly coupled spins. As a demonstration of its efficacy at 3.0 T, the strategy is shown to enhance by a factor of approximately 5 the signal-to-background ratio of the myo-inositol band at 3.6 ppm relative to that in response to a PRESS sequence with the same sequence timings. This is done by eliminating the uncoupled resonance of glycine and the weakly coupled multiplets of glutamate and glutamine, and by selectively suppressing the strongly coupled taurine multiplet 3-fold. The macromolecular background was effectively removed through its transverse decay over 105 ms. The associated cost of gaining the signal to background enhancement is a drop in signal yield by a factor of 0.75 relative to PRESS at the same timings. The myo-inositol signal to noise ratio was nevertheless maintained by the filter at approximately 12.
Collapse
Affiliation(s)
- Hyeonjin Kim
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada
| | | | | |
Collapse
|
24
|
Choi IY, Lee SP, Merkle H, Shen J. Single-shot two-echo technique for simultaneous measurement of GABA and creatine in the human brain in vivo. Magn Reson Med 2004; 51:1115-21. [PMID: 15170830 DOI: 10.1002/mrm.20082] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
A single-shot, two-echo method for the simultaneous detection of multiple-quantum (MQ)-filtered gamma-aminobutyric acid (GABA) and creatine (Cr) was developed and demonstrated in the human brain in vivo at 3 Tesla. The simultaneously measured Cr singlet served as a navigator for the spectral phase of GABA and any frequency shift during measurements due to drift in the static magnetic field (B(0)) or subject movement, as well as an internal concentration reference. In addition, the use of a double-band frequency-selective MQ filter for C(3) and C(4) methylene protons of GABA provided a very robust measurement of GABA, with excellent suppression of overlapping metabolites such as Cr and glutathione (GSH) in each single scan. Contamination from overlapping macromolecules was also demonstrated to be negligible with this method. The GABA-to-Cr ratio was 0.09 +/- 0.03 (mean +/- SD, N = 17) and the estimated concentration of GABA in the frontoparietal region of the human brain in vivo was 0.66 +/- 0.19 micromol/g (mean +/- SD, N = 17) with the internal reference method, and 0.69 +/- 0.18 micromol/g (mean +/- SD, N = 17) with the external reference method. The observed pattern of GABA doublet was consistent among all subjects, with a frequency separation of approximately 13 Hz.
Collapse
Affiliation(s)
- In-Young Choi
- Nathan Kline Institute, Medical Physics, Orangeburg, New York 10962, USA.
| | | | | | | |
Collapse
|
25
|
Du F, Chu WJ, Yang B, Den Hollander JA, Ng TC. In vivo GABA detection with improved selectivity and sensitivity by localized double quantum filter technique at 4.1T. Magn Reson Imaging 2004; 22:103-8. [PMID: 14972399 DOI: 10.1016/j.mri.2003.06.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2002] [Revised: 06/02/2003] [Accepted: 06/03/2003] [Indexed: 11/24/2022]
Abstract
Gamma-aminobutyric acid (GABA) is the major inhibitory neurotransmitter for the normal function of mammal and human brain. It is difficult to detect GABA signal with the conventional single quantum technique due to its relatively low concentration and overlapping with other signals from creatine (Cr), glutathione (GSH), as well as macromolecules. Using a high-selective read pulse, DANTE, and at the facility of increased sensitivity and chemical shift resolution at high-field 4.1T, GABA editing by double quantum filter (DQF) with robust suppression of Cr and GSH was achieved. Our editing efficiency of 40-50% was achievable on a GABA phantom (50 mM GABA and 61 mM choline). Furthermore, GABA editing spectra were acquired with echo time TE = 77 ms, and any possible macromolecular contamination to GABA editing spectra was found to be negligible. This high-field DQF setup was applied to 11 healthy volunteers, and the mean GABA level was measured to be 1.12 +/- 0.15 mM in the occipital lobe in reference to 7.1 mM Cr concentration.
Collapse
Affiliation(s)
- Fei Du
- Department of Medicine and Comprehensive Cancer Center, School of Medicine, University of Alabama at Birmingham, Birmingham, AL 35205, USA
| | | | | | | | | |
Collapse
|
26
|
Trabesinger AH, Meier D, Boesiger P. In vivo 1H NMR spectroscopy of individual human brain metabolites at moderate field strengths. Magn Reson Imaging 2003; 21:1295-302. [PMID: 14725936 DOI: 10.1016/j.mri.2003.08.029] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
This article reviews spectral editing techniques for in vivo 1H NMR spectroscopy of human brain tissue at moderate field strengths of 1.5-3 Tesla. Various aspects of 1H NMR spectroscopy are discussed with regard to in vivo applications. The parameter set [delta, J, n] (delta being the relative chemical shift, J the scalar coupling constant and n the number of coupled spins) is used to characterize the spin systems under investigation and to classify the editing techniques that are used in in vivo 1H NMR spectroscopy.
Collapse
Affiliation(s)
- Andreas H Trabesinger
- Institute for Biomedical Engineering, Swiss Federal Institute of Technology (ETH), Zurich, Switzerland
| | | | | |
Collapse
|