1
|
Erley J, Zieschang V, Lapinskas T, Demir A, Wiesemann S, Haass M, Osman NF, Simonetti OP, Liu Y, Patel AR, Mor-Avi V, Unal O, Johnson KM, Pieske B, Hansmann J, Schulz-Menger J, Kelle S. A multi-vendor, multi-center study on reproducibility and comparability of fast strain-encoded cardiovascular magnetic resonance imaging. Int J Cardiovasc Imaging 2020; 36:899-911. [PMID: 32056087 PMCID: PMC7174273 DOI: 10.1007/s10554-020-01775-y] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Accepted: 01/11/2020] [Indexed: 01/23/2023]
Abstract
Myocardial strain is a convenient parameter to quantify left ventricular (LV) function. Fast strain-encoding (fSENC) enables the acquisition of cardiovascular magnetic resonance images for strain-measurement within a few heartbeats during free-breathing. It is necessary to analyze inter-vendor agreement of techniques to determine strain, such as fSENC, in order to compare existing studies and plan multi-center studies. Therefore, the aim of this study was to investigate inter-vendor agreement and test-retest reproducibility of fSENC for three major MRI-vendors. fSENC-images were acquired three times in the same group of 15 healthy volunteers using 3 Tesla scanners from three different vendors: at the German Heart Institute Berlin, the Charité University Medicine Berlin-Campus Buch and the Theresien-Hospital Mannheim. Volunteers were scanned using the same imaging protocol composed of two fSENC-acquisitions, a 15-min break and another two fSENC-acquisitions. LV global longitudinal and circumferential strain (GLS, GCS) were analyzed by a trained observer (Myostrain 5.0, Myocardial Solutions) and for nine volunteers repeatedly by another observer. Inter-vendor agreement was determined using Bland-Altman analysis. Test-retest reproducibility and intra- and inter-observer reproducibility were analyzed using intraclass correlation coefficient (ICC) and coefficients of variation (CoV). Inter-vendor agreement between all three sites was good for GLS and GCS, with biases of 0.01–1.88%. Test-retest reproducibility of scans before and after the break was high, shown by ICC- and CoV values of 0.63–0.97 and 3–9% for GLS and 0.69–0.82 and 4–7% for GCS, respectively. Intra- and inter-observer reproducibility were excellent for both parameters (ICC of 0.77–0.99, CoV of 2–5%). This trial demonstrates good inter-vendor agreement and test–retest reproducibility of GLS and GCS measurements, acquired at three different scanners from three different vendors using fSENC. The results indicate that it is necessary to account for a possible bias (< 2%) when comparing strain measurements of different scanners. Technical differences between scanners, which impact inter-vendor agreement, should be further analyzed and minimized. DRKS Registration Number: 00013253. Universal Trial Number (UTN): U1111-1207-5874.
Collapse
Affiliation(s)
- Jennifer Erley
- Department of Internal Medicine/Cardiology, German Heart Institute Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Victoria Zieschang
- Department of Internal Medicine/Cardiology, German Heart Institute Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Tomas Lapinskas
- Department of Internal Medicine/Cardiology, German Heart Institute Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.,Department of Cardiology, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Aylin Demir
- Working Group Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, Max-Delbrueck Center for Molecular Medicine, Department of Cardiology and Nephrology, Charité Medical Faculty, HELIOS Klinikum Berlin Buch, Berlin, Germany
| | - Stephanie Wiesemann
- Working Group Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, Max-Delbrueck Center for Molecular Medicine, Department of Cardiology and Nephrology, Charité Medical Faculty, HELIOS Klinikum Berlin Buch, Berlin, Germany
| | - Markus Haass
- Department of Internal Medicine/Cardiology/Angiology, Theresienkrankenhaus Und St. Hedwig-Klinik, Mannheim, Germany
| | - Nael F Osman
- Department of Radiology and Radiological Science, School of Medicine, John Hopkins University, Baltimore, MD, USA.,Myocardial Solutions, Inc, Morrisville, NC, USA
| | - Orlando P Simonetti
- Departments of Internal Medicine and Radiology, The Ohio State University, Columbus, OH, USA
| | - Yingmin Liu
- Dorothy M. Davis Heart and Lung Research Institute, Wexner Medical Center, The Ohio State University, Columbus, OH, USA
| | - Amit R Patel
- Department of Cardiology, University of Chicago Medicine, Chicago, IL, USA
| | - Victor Mor-Avi
- Department of Cardiology, University of Chicago Medicine, Chicago, IL, USA
| | - Orhan Unal
- Departments of Radiology and Medical Physics, University of Wisconsin-Madison, Madison, WI, USA
| | - Kevin M Johnson
- Departments of Radiology and Medical Physics, University of Wisconsin-Madison, Madison, WI, USA
| | - Burkert Pieske
- Department of Internal Medicine/Cardiology, German Heart Institute Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.,Department of Internal Medicine/Cardiology, Charité Campus Virchow Klinikum, Berlin, Germany.,DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
| | - Jochen Hansmann
- Department of Radiology, Theresienkrankenhaus Und St. Hedwig-Klinik, Mannheim, Germany
| | - Jeanette Schulz-Menger
- Working Group Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, Max-Delbrueck Center for Molecular Medicine, Department of Cardiology and Nephrology, Charité Medical Faculty, HELIOS Klinikum Berlin Buch, Berlin, Germany.,DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
| | - Sebastian Kelle
- Department of Internal Medicine/Cardiology, German Heart Institute Berlin, Augustenburger Platz 1, 13353, Berlin, Germany. .,Department of Internal Medicine/Cardiology, Charité Campus Virchow Klinikum, Berlin, Germany. .,DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany.
| |
Collapse
|
2
|
Clinical and Advanced MRI Techniques for Detection of Checkpoint Inhibitor Associated Myocarditis. CURRENT CARDIOVASCULAR IMAGING REPORTS 2020. [DOI: 10.1007/s12410-019-9521-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Abstract
Purpose of Review
With the advent of immune checkpoint inhibitors (ICIs), cancer treatment has been revolutionized; however, these agents are associated with immune-related adverse events, including myocarditis, which ranges from mild to fulminant in severity. Currently, there are no established guidelines in diagnosing ICI-associated myocarditis, and the gold standard test for diagnosis of myocarditis in general is invasive endomyocardial biopsy (EMB). Cardiac magnetic resonance (CMR) imaging is a noninvasive test with the advantage of providing structural, functional and tissue characterization information. Additionally, it provides high spatial and temporal resolution without exposure to ionizing radiation, iodinated contrast, or radioactive isotopes.
Recent Findings
With an increasing number of reported cases of ICI associated myocarditis, understanding of the disease process and associated CMR findings is growing. Diagnostic testing with cardiac biomarkers, electrocardiogram, and echocardiogram can be nonspecific and EMB can have sampling errors. CMR as a diagnostic tool can provide functional assessment of biventricular ejection fraction, myocardial strain, tissue characterization of myocardial edema and inflammation as well as fibrosis. Furthermore, with advanced parametric mapping techniques, CMR provides even more sensitive and quantitative information about myocardial inflammation and fibrosis, including measurements of extracellular volume.
Summary
ICI-associated myocarditis is a serious immune adverse event, and CMR plays a vital role in establishing its diagnosis, providing prognostic information, and has the potential for use as a tool for screening and serial monitoring in patients exposed to ICIs.
Collapse
|
3
|
Kawaji K, Nazir N, Blair JA, Mor-Avi V, Besser S, Matsumoto K, Goes JP, Dabir D, Stoiber L, Kelle S, Zamani SM, Holzhauser L, Lang RM, Patel AR. Quantitative detection of changes in regional wall motion using real time strain-encoded cardiovascular magnetic resonance. Magn Reson Imaging 2019; 66:193-198. [PMID: 31484044 DOI: 10.1016/j.mri.2019.08.033] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2019] [Revised: 07/21/2019] [Accepted: 08/31/2019] [Indexed: 11/19/2022]
Affiliation(s)
- Keigo Kawaji
- Department of Medicine-Section of Cardiology, University of Chicago Medical Center, Chicago, IL, USA; Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA.
| | - Noreen Nazir
- Department of Medicine-Section of Cardiology, University of Chicago Medical Center, Chicago, IL, USA
| | - John A Blair
- Department of Medicine-Section of Cardiology, University of Chicago Medical Center, Chicago, IL, USA
| | - Victor Mor-Avi
- Department of Medicine-Section of Cardiology, University of Chicago Medical Center, Chicago, IL, USA
| | - Stephanie Besser
- Department of Medicine-Section of Cardiology, University of Chicago Medical Center, Chicago, IL, USA
| | - Kohei Matsumoto
- Department of Medicine-Section of Cardiology, University of Chicago Medical Center, Chicago, IL, USA
| | - Jacob P Goes
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Darius Dabir
- Department of Radiology, University of Bonn, Bonn, Germany
| | - Lukas Stoiber
- Department of Internal Medicine/Cardiology, German Heart Center Berlin, Berlin, Germany
| | - Sebastian Kelle
- Department of Internal Medicine/Cardiology, German Heart Center Berlin, Berlin, Germany; Department of Cardiology, Charité-University-Medicine Berlin, Germany; DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, Germany
| | | | - Luise Holzhauser
- Department of Medicine-Section of Cardiology, University of Chicago Medical Center, Chicago, IL, USA
| | - Roberto M Lang
- Department of Medicine-Section of Cardiology, University of Chicago Medical Center, Chicago, IL, USA
| | - Amit R Patel
- Department of Medicine-Section of Cardiology, University of Chicago Medical Center, Chicago, IL, USA
| |
Collapse
|
4
|
Deligianni X, Pansini M, Garcia M, Hirschmann A, Schmidt‐Trucksäss A, Bieri O, Santini F. Synchronous MRI of muscle motion induced by electrical stimulation. Magn Reson Med 2016; 77:664-672. [DOI: 10.1002/mrm.26154] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2015] [Revised: 12/21/2015] [Accepted: 01/17/2016] [Indexed: 11/08/2022]
Affiliation(s)
- Xeni Deligianni
- Department of Radiology, Division of Radiological PhysicsUniversity of Basel HospitalBasel Switzerland
- Department of Biomedical EngineeringUniversity of BaselBasel Switzerland
| | - Michele Pansini
- Department of RadiologyKantonsspital Basel‐Landschaft BruderholzBruderholz Switzerland
| | - Meritxell Garcia
- Department of RadiologyUniversity of Basel HospitalBasel Switzerland
| | - Anna Hirschmann
- Department of RadiologyUniversity of Basel HospitalBasel Switzerland
| | | | - Oliver Bieri
- Department of Radiology, Division of Radiological PhysicsUniversity of Basel HospitalBasel Switzerland
- Department of Biomedical EngineeringUniversity of BaselBasel Switzerland
| | - Francesco Santini
- Department of Radiology, Division of Radiological PhysicsUniversity of Basel HospitalBasel Switzerland
- Department of Biomedical EngineeringUniversity of BaselBasel Switzerland
| |
Collapse
|
5
|
Low G, Kruse SA, Lomas DJ. General review of magnetic resonance elastography. World J Radiol 2016; 8:59-72. [PMID: 26834944 PMCID: PMC4731349 DOI: 10.4329/wjr.v8.i1.59] [Citation(s) in RCA: 57] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2015] [Revised: 11/14/2015] [Accepted: 12/04/2015] [Indexed: 02/06/2023] Open
Abstract
Magnetic resonance elastography (MRE) is an innovative imaging technique for the non-invasive quantification of the biomechanical properties of soft tissues via the direct visualization of propagating shear waves in vivo using a modified phase-contrast magnetic resonance imaging (MRI) sequence. Fundamentally, MRE employs the same physical property that physicians utilize when performing manual palpation - that healthy and diseased tissues can be differentiated on the basis of widely differing mechanical stiffness. By performing “virtual palpation”, MRE is able to provide information that is beyond the capabilities of conventional morphologic imaging modalities. In an era of increasing adoption of multi-parametric imaging approaches for solving complex problems, MRE can be seamlessly incorporated into a standard MRI examination to provide a rapid, reliable and comprehensive imaging evaluation at a single patient appointment. Originally described by the Mayo Clinic in 1995, the technique represents the most accurate non-invasive method for the detection and staging of liver fibrosis and is currently performed in more than 100 centers worldwide. In this general review, the mechanical properties of soft tissues, principles of MRE, clinical applications of MRE in the liver and beyond, and limitations and future directions of this discipline -are discussed. Selected diagrams and images are provided for illustration.
Collapse
|
6
|
Speelman L, Teng Z, Nederveen AJ, van der Lugt A, Gillard JH. MRI-based biomechanical parameters for carotid artery plaque vulnerability assessment. Thromb Haemost 2016; 115:493-500. [PMID: 26791734 DOI: 10.1160/th15-09-0712] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2015] [Accepted: 12/13/2015] [Indexed: 12/18/2022]
Abstract
Carotid atherosclerotic plaques are a major cause of ischaemic stroke. The biomechanical environment to which the arterial wall and plaque is subjected to plays an important role in the initiation, progression and rupture of carotid plaques. MRI is frequently used to characterize the morphology of a carotid plaque, but new developments in MRI enable more functional assessment of carotid plaques. In this review, MRI based biomechanical parameters are evaluated on their current status, clinical applicability, and future developments. Blood flow related biomechanical parameters, including endothelial wall shear stress and oscillatory shear index, have been shown to be related to plaque formation. Deriving these parameters directly from MRI flow measurements is feasible and has great potential for future carotid plaque development prediction. Blood pressure induced stresses in a plaque may exceed the tissue strength, potentially leading to plaque rupture. Multi-contrast MRI based stress calculations in combination with tissue strength assessment based on MRI inflammation imaging may provide a plaque stress-strength balance that can be used to assess the plaque rupture risk potential. Direct plaque strain analysis based on dynamic MRI is already able to identify local plaque displacement during the cardiac cycle. However, clinical evidence linking MRI strain to plaque vulnerability is still lacking. MRI based biomechanical parameters may lead to improved assessment of carotid plaque development and rupture risk. However, better MRI systems and faster sequences are required to improve the spatial and temporal resolution, as well as increase the image contrast and signal-to-noise ratio.
Collapse
Affiliation(s)
- Lambert Speelman
- Dr. Lambert Speelman, Department of Biomedical Engineering, Ee 23.38B, P.O Box 2040, 3000 CA Rotterdam, the Netherlands, Tel.: +31 10 70 44039, Fax: +31 10 70 44720, E-mail:
| | | | | | | | | |
Collapse
|
7
|
Harouni AA, Gharib AM, Osman NF, Morse C, Heller T, Abd-Elmoniem KZ. Assessment of liver fibrosis using fast strain-encoded MRI driven by inherent cardiac motion. Magn Reson Med 2015; 74:106-114. [PMID: 25081734 PMCID: PMC4312549 DOI: 10.1002/mrm.25379] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2014] [Revised: 06/18/2014] [Accepted: 07/01/2014] [Indexed: 02/06/2023]
Abstract
PURPOSE An external driver-free MRI method for assessment of liver fibrosis offers a promising noninvasive tool for diagnosis and monitoring of liver disease. Lately, the heart's intrinsic motion and MR tagging have been utilized for the quantification of liver strain. However, MR tagging requires multiple breath-hold acquisitions and substantial postprocessing. In this study, we propose the use of a fast strain-encoded (FSENC) MRI method to measure the peak strain (Sp ) in the liver's left lobe, which is in close proximity and caudal to the heart. Additionally, we introduce a new method of measuring heart-induced shear wave velocity (SWV) inside the liver. METHODS Phantom and in vivo experiments (11 healthy subjects and 11 patients with liver fibrosis) were conducted. Reproducibility experiments were performed in seven healthy subjects. RESULTS Peak liver strain, Sp , decreased significantly in fibrotic liver compared with healthy liver (6.46% ± 2.27% vs 12.49% ± 1.76%; P < 0.05). Heart-induced SWV increased significantly in patients compared with healthy subjects (0.15 ± 0.04 m/s vs 0.63 ± 0.32 m/s; P < 0.05). Reproducibility analysis yielded no significant difference in Sp (P = 0.47) or SWV (P = 0.56). CONCLUSION Accelerated external driver-free noninvasive assessment of left liver lobe strain and SWV is feasible using strain-encoded MRI. The two measures significantly separate healthy subjects from patients with fibrotic liver. Magn Reson Med 74:106-114, 2015. © 2014 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Ahmed A. Harouni
- Biomedical and Metabolic Imaging Branch, The National Institute of Diabetes and Digestive and Kidney Diseases, The National Institutes of Health, Bethesda, MD
| | - Ahmed M. Gharib
- Biomedical and Metabolic Imaging Branch, The National Institute of Diabetes and Digestive and Kidney Diseases, The National Institutes of Health, Bethesda, MD
| | - Nael F. Osman
- Russell H. Morgan Department of Radiology and Radiological Sciences, Division of MR Research, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Caryn Morse
- Critical Care Medicine Department, Clinical Research Center, The National Institutes of Health, Bethesda, MD
| | - Theo Heller
- Liver Diseases Branch, The National Institute of Diabetes and Digestive and Kidney Diseases, The National Institutes of Health, Bethesda, MD
| | - Khaled Z. Abd-Elmoniem
- Biomedical and Metabolic Imaging Branch, The National Institute of Diabetes and Digestive and Kidney Diseases, The National Institutes of Health, Bethesda, MD
| |
Collapse
|
8
|
Nederveen AJ, Avril S, Speelman L. MRI strain imaging of the carotid artery: present limitations and future challenges. J Biomech 2014; 47:824-33. [PMID: 24468207 DOI: 10.1016/j.jbiomech.2014.01.014] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/13/2014] [Indexed: 11/18/2022]
Abstract
Rupture of atherosclerotic plaques in the carotid artery is a main cause of stroke. Current diagnostics are not sufficient to identify all rupture-prone plaques, and studies have shown that biomechanical factors improve current plaque risk assessment. Strain imaging may be a valuable contribution to this risk assessment. MRI is a versatile imaging technique that offers various methods that are capable of measuring tissue strain. In this review, MR imaging techniques with displacement (DENSE), velocity (PC MRI), or strain (SENC) encoding protocols are discussed, together with post-processing techniques based on time-resolved MRI data. Although several MRI techniques are being developed to improve time-resolved MR imaging, current technical limitations related to spatial and temporal resolutions render MRI strain imaging currently unfit for carotid plaque strain evaluation. A novel approach using non-rigid image registration of MR images to determine strain in carotid arteries based on black blood cine MRI is proposed in this review. This and other post-processing techniques based on time-resolved MRI data may provide a good estimate of plaque strain, but are also dependent on the spatial and temporal resolution of the MR images. However, they seem to be the most promising approach for MRI based plaque strain analysis in the near future.
Collapse
Affiliation(s)
- Aart J Nederveen
- Department of Radiology, Academic Medical Center Amsterdam, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
| | - Stéphane Avril
- Center for Biomedical and Healthcare Engineering, Ecole Nationale Supérieure des Mines de Saint-Étienne, France
| | - Lambert Speelman
- Department of Biomedical Engineering, Erasmus MC Rotterdam, The Netherlands
| |
Collapse
|
9
|
Haruoni AA, Hossain J, El Khouli R, Matsuda KM, Bluemke DA, Osman NF, Jacobs MA. Strain-encoded breast MRI in phantom and ex vivo specimens with histological validation: preliminary results. Med Phys 2013; 39:7710-8. [PMID: 23231318 DOI: 10.1118/1.4749963] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
PURPOSE To evaluate the feasibility of using strain-encoded (SENC) breast magnetic resonance images (MRI) for breast cancer detection by examining the compression and relaxation response properties in phantoms and ex vivo breast samples. METHODS A tissue phantom was constructed to mimic different sizes of breast masses and tissue stiffness. In addition, five human ex vivo whole breast specimens with and without masses were studied. MR data was acquired on a 3T scanner consisting of T(1)-weighted, fat suppressed spin echo T(2)-weighted, and SENC breast images. Mechanical tissue characteristics (strain) of the phantoms and breast tissue samples were measured using SENC imaging in both compression and relaxation modes. The breast tissue specimens were sectioned and stained in the same plane as the MRI for histological evaluation. RESULTS For the phantom, SENC images showed soft masses with quantitative strain values between 35% and 50%, while harder masses had strain values between 0% and 20%. Combined compression (CMP) and relaxation (REX) breast SENC images separately categorized all masses into three different groups. For breast SENC, the signal intensities between ex vivo breast mass and breast glandular tissue were significantly different (-7.6 ± 2.6 verses -20.6 ± 5.4 for SENC-CMP, and 4.2 ± 1.5 verses 22.6 ± 5 for SENC-REX, p < 0.05). CONCLUSIONS We have demonstrated that SENC breast MRI can be used to obtain mechanical tissue properties and give quantitative estimates of strain in tumors. This feasibility study provides the basis for future clinical studies.
Collapse
Affiliation(s)
- Ahmed A Haruoni
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, USA
| | | | | | | | | | | | | |
Collapse
|
10
|
Combination of tagging and tissue phase mapping to accelerate myocardial motion measurements in three directions. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2012; 26:239-47. [PMID: 22864666 DOI: 10.1007/s10334-012-0333-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2012] [Revised: 07/17/2012] [Accepted: 07/19/2012] [Indexed: 10/27/2022]
Abstract
OBJECT Until now, a three-directional velocity field has mostly been obtained by velocity encoding in three directions, which is very time-consuming and hence not usually used in clinical routine. We show the feasibility of combining in-plane tagging with through-plane tissue phase mapping (TPM) to encode a three-directional velocity field at 3 T with reduced overall acquisition time. MATERIALS AND METHODS Assessment of a three-directional velocity field was performed for 10 healthy volunteers. The motion patterns obtained by use of five different sequences including three-directional TPM, TPM in the through-plane direction, TPM in the through-plane direction with horizontal or vertical tagging lines, and TPM in the through-plane direction combined with a tagging grid were evaluated and compared. RESULTS A three-dimensional velocity field can be obtained in approximately half the acquisition time by combining through-plane TPM with in-plane tagging. Although the velocity information is derived by different means, differences between the information obtained by three-directional TPM encoding and the suggested technique are only minor. CONCLUSION The combination of tagging and TPM enables assessment of the three-directional velocity field in nearly half the time taken when the conventional three-directional TPM sequence is used.
Collapse
|
11
|
Wang H, Amini AA. Cardiac motion and deformation recovery from MRI: a review. IEEE TRANSACTIONS ON MEDICAL IMAGING 2012; 31:487-503. [PMID: 21997253 DOI: 10.1109/tmi.2011.2171706] [Citation(s) in RCA: 80] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Magnetic resonance imaging (MRI) is a highly advanced and sophisticated imaging modality for cardiac motion tracking and analysis, capable of providing 3D analysis of global and regional cardiac function with great accuracy and reproducibility. In the past few years, numerous efforts have been devoted to cardiac motion recovery and deformation analysis from MR image sequences. Many approaches have been proposed for tracking cardiac motion and for computing deformation parameters and mechanical properties of the heart from a variety of cardiac MR imaging techniques. In this paper, an updated and critical review of cardiac motion tracking methods including major references and those proposed in the past ten years is provided. The MR imaging and analysis techniques surveyed are based on cine MRI, tagged MRI, phase contrast MRI, DENSE, and SENC. This paper can serve as a tutorial for new researchers entering the field.
Collapse
Affiliation(s)
- Hui Wang
- Department of Electrical and Computer Engineering,University of Louisville, Louisville, KY 40292 USA.
| | | |
Collapse
|
12
|
Abstract
Often compared to the practice of manual palpation, magnetic resonance elastography is an emerging technology for quantitatively assessing the mechanical properties of tissue as a basis for characterizing disease. The potential of MRE as a diagnostic tool is rooted in the fact that normal and diseased tissues often differ significantly in terms of their intrinsic mechanical properties. MRE uses magnetic resonance imaging (MRI) in conjunction with the application of mechanical shear waves to probe tissue mechanics. This process can be broken down into three essential steps: inducing shear waves in the tissue,imaging the propagating shear waves with MRI, andanalyzing the wave data to generate quantitative images of tissue stiffness MRE has emerged as a safe, reliable and noninvasive method for staging hepatic liver fibrosis, and is now used in some locations as an alternative to biopsy. MRE is also being used in the ongoing investigations of numerous other organs and tissues, including, for example, the spleen, kidney, pancreas, brain, heart, breast, skeletal muscle, prostate, vasculature, lung, spinal cord, eye, bone, and cartilage. In the article that follows, some fundamental techniques and applications of MRE are summarized.
Collapse
|
13
|
Lutz A, Bornstedt A, Manzke R, Etyngier P, Nienhaus GU, Rottbauer W, Rasche V. Acceleration of tissue phase mapping with sensitivity encoding at 3T. J Cardiovasc Magn Reson 2011; 13:59. [PMID: 21992267 PMCID: PMC3217863 DOI: 10.1186/1532-429x-13-59] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2011] [Accepted: 10/12/2011] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The objective of this study was to investigate the impact of sensitivity encoding on the quantitative assessment of cardiac motion in black blood cine tissue phase mapping (TPM) sequences. Up to now whole volume coverage of the heart is still limited by the long acquisition times. Therefore, a significant increase in imaging speed without deterioration of quantitative motion information is indispensable. METHODS 20 volunteers were enrolled in this study. Each volunteer underwent myocardial short-axis TPM scans with different SENSE acceleration factors. The influence of SENSE acceleration on the measured motion curves was investigated. RESULTS It is demonstrated that all TPM sequences with SENSE acceleration have only minimum influence on the motion curves. Even with a SENSE factor of four, the decrease in the amplitude of the motion curve was less than 3%. No significant difference was observed for the global correlation coefficient and deviation between the motion curves obtained by the reproducibility and the SENSE accelerated measurements. CONCLUSIONS It is feasible to accelerate myocardial TPM measurements with SENSE factors up to 4 without losing substantial information of the motion pattern.
Collapse
Affiliation(s)
- Anja Lutz
- Department of Internal Medicine II, University Hospital of Ulm, Ulm Germany
| | - Axel Bornstedt
- Department of Internal Medicine II, University Hospital of Ulm, Ulm Germany
| | - Robert Manzke
- Philips Research North America, Briarcliff Manor, USA
| | | | | | - Wolfgang Rottbauer
- Department of Internal Medicine II, University Hospital of Ulm, Ulm Germany
| | - Volker Rasche
- Department of Internal Medicine II, University Hospital of Ulm, Ulm Germany
| |
Collapse
|
14
|
Ibrahim ESH. Myocardial tagging by cardiovascular magnetic resonance: evolution of techniques--pulse sequences, analysis algorithms, and applications. J Cardiovasc Magn Reson 2011; 13:36. [PMID: 21798021 PMCID: PMC3166900 DOI: 10.1186/1532-429x-13-36] [Citation(s) in RCA: 203] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2011] [Accepted: 07/28/2011] [Indexed: 02/06/2023] Open
Abstract
Cardiovascular magnetic resonance (CMR) tagging has been established as an essential technique for measuring regional myocardial function. It allows quantification of local intramyocardial motion measures, e.g. strain and strain rate. The invention of CMR tagging came in the late eighties, where the technique allowed for the first time for visualizing transmural myocardial movement without having to implant physical markers. This new idea opened the door for a series of developments and improvements that continue up to the present time. Different tagging techniques are currently available that are more extensive, improved, and sophisticated than they were twenty years ago. Each of these techniques has different versions for improved resolution, signal-to-noise ratio (SNR), scan time, anatomical coverage, three-dimensional capability, and image quality. The tagging techniques covered in this article can be broadly divided into two main categories: 1) Basic techniques, which include magnetization saturation, spatial modulation of magnetization (SPAMM), delay alternating with nutations for tailored excitation (DANTE), and complementary SPAMM (CSPAMM); and 2) Advanced techniques, which include harmonic phase (HARP), displacement encoding with stimulated echoes (DENSE), and strain encoding (SENC). Although most of these techniques were developed by separate groups and evolved from different backgrounds, they are in fact closely related to each other, and they can be interpreted from more than one perspective. Some of these techniques even followed parallel paths of developments, as illustrated in the article. As each technique has its own advantages, some efforts have been made to combine different techniques together for improved image quality or composite information acquisition. In this review, different developments in pulse sequences and related image processing techniques are described along with the necessities that led to their invention, which makes this article easy to read and the covered techniques easy to follow. Major studies that applied CMR tagging for studying myocardial mechanics are also summarized. Finally, the current article includes a plethora of ideas and techniques with over 300 references that motivate the reader to think about the future of CMR tagging.
Collapse
|
15
|
Harouni AA, Hossain J, Jacobs MA, Osman NF. Improved hardware for higher spatial resolution strain-encoded (SENC) breast MRI for strain measurements. Acad Radiol 2011; 18:705-15. [PMID: 21440464 DOI: 10.1016/j.acra.2011.01.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2010] [Revised: 01/04/2011] [Accepted: 01/07/2011] [Indexed: 12/27/2022]
Abstract
RATIONALE AND OBJECTIVES Early detection of breast lesions using mammography has resulted in lower mortality rates. However, some breast lesions are mammography occult, and magnetic resonance imaging (MRI) is recommended, but it has lower specificity. It is possible to achieve higher specificity by using strain-encoded (SENC) MRI and/or magnetic resonance elastography. SENC breast MRI can measure the strain properties of breast tissue. Similarly, magnetic resonance elastography is used to measure the elasticity (ie, shear stiffness) of different tissue compositions interrogating the tissue mechanical properties. Reports have shown that malignant tumors are three to 13 times stiffer than normal tissue and benign tumors. MATERIALS AND METHODS The investigators have developed a SENC breast hardware device capable of periodically compressing the breast, thus allowing for longer scanning time and measuring the strain characteristics of breast tissue. This hardware enables the use of SENC MRI with high spatial resolution (1 × 1 × 5 mm(3)) instead of fast SENC imaging. Simple controls and multiple safety measures were added to ensure accurate, repeatable, and safe in vivo experiments. RESULTS Phantom experiments showed that SENC breast MRI has higher signal-to-noise ratio and contrast-to-noise ratio than fast SENC imaging under different scanning resolutions. Finally, the SENC breast device reproducibility measurements resulted in a difference of <1 mm with a 1% strain difference. CONCLUSIONS SENC breast magnetic resonance images have higher signal-to-noise ratio and contrast-to-noise ratios than fast SENC images. Thus, combining SENC breast strain measurements with diagnostic breast MRI to differentiate benign from malignant lesions could potentially increase the specificity of diagnosis in the clinical setting.
Collapse
Affiliation(s)
- Ahmed A Harouni
- Department of Electrical and Computer Engineering, The Johns Hopkins University, Baltimore, MD 21218, USA
| | | | | | | |
Collapse
|
16
|
Three-directional acceleration phase mapping of myocardial function. Magn Reson Med 2011; 65:1335-45. [DOI: 10.1002/mrm.22744] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2010] [Revised: 10/20/2010] [Accepted: 11/07/2010] [Indexed: 11/07/2022]
|
17
|
Lutz A, Bornstedt A, Manzke R, Etyngier P, Nienhaus GU, Rasche V. Acceleration of tissue phase mapping by k-t BLAST: a detailed analysis of the influence of k-t-BLAST for the quantification of myocardial motion at 3T. J Cardiovasc Magn Reson 2011; 13:5. [PMID: 21223566 PMCID: PMC3024407 DOI: 10.1186/1532-429x-13-5] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2010] [Accepted: 01/11/2011] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The assessment of myocardial motion with tissue phase mapping (TPM) provides high spatiotemporal resolution and quantitative motion information in three directions. Today, whole volume coverage of the heart by TPM encoding at high spatial and temporal resolution is limited by long data acquisition times. Therefore, a significant increase in imaging speed without deterioration of the quantitative motion information is required. For this purpose, the k-t BLAST acceleration technique was combined with TPM black-blood functional imaging of the heart. Different k-t factors were evaluated with respect to their impact on the quantitative assessment of cardiac motion. RESULTS It is demonstrated that a k-t BLAST factor of two can be used with a marginal, but statistically significant deterioration of the quantitative motion data. Further increasing the k-t acceleration causes substantial alteration of the peak velocities and the motion pattern, but the temporal behavior of the contraction is well maintained up to an acceleration factor of six. CONCLUSIONS The application of k-t BLAST for the acceleration of TPM appears feasible. A reduction of the acquisition time of almost 45% could be achieved without substantial loss of quantitative motion information.
Collapse
Affiliation(s)
- Anja Lutz
- Department of Internal Medicine II, University Hospital of Ulm, Ulm, Baden-Württemberg, Germany
| | - Axel Bornstedt
- Department of Internal Medicine II, University Hospital of Ulm, Ulm, Baden-Württemberg, Germany
| | | | | | - G Ulrich Nienhaus
- Institute of Applied Physics Karlsruhe, Institute of Technology (KIT), Karlsruhe, Germany
| | - Volker Rasche
- Department of Internal Medicine II, University Hospital of Ulm, Ulm, Baden-Württemberg, Germany
| |
Collapse
|
18
|
Finding the optimal compression level for strain-encoded (SENC) breast MRI; simulations and phantom experiments. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION : MICCAI ... INTERNATIONAL CONFERENCE ON MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION 2011; 14:444-51. [PMID: 22003648 DOI: 10.1007/978-3-642-23623-5_56] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Breast cancer is the most common cancer among women and the second highest cause of cancer-related death. Diagnostic magnetic resonance imaging (MRI) is recommended to screen high-risk patients. Strain-Encoded (SENC) can improve MRI's specificity by detecting and differentiating masses according to their stiffness. Previous phantom and ex-vivo studies have utilized SENC to detect cancerous masses. However, SENC required a 30% compression of the tissue, which may not be feasible for in-vivo imaging. In this work, we use finite element method simulations and phantom experiments to determine the minimum compression required to detect and classify masses. Results show that SENC is capable of detecting stiff masses at compression level of 7%, though higher compression is needed in order to differentiate between normal tissue and benign or malignant masses. With on-line SENC calculations implemented on the scanner console, we propose to start with small compressions for maximum patient comfort, then progress to larger compressions if any masses are detected.
Collapse
|
19
|
Abstract
Magnetic resonance elastography (MRE) is a rapidly developing technology for quantitatively assessing the mechanical properties of tissue. The technology can be considered to be an imaging-based counterpart to palpation, commonly used by physicians to diagnose and characterize diseases. The success of palpation as a diagnostic method is based on the fact that the mechanical properties of tissues are often dramatically affected by the presence of disease processes, such as cancer, inflammation, and fibrosis. MRE obtains information about the stiffness of tissue by assessing the propagation of mechanical waves through the tissue with a special magnetic resonance imaging technique. The technique essentially involves three steps: (1) generating shear waves in the tissue, (2) acquiring MR images depicting the propagation of the induced shear waves, and (3) processing the images of the shear waves to generate quantitative maps of tissue stiffness, called elastograms. MRE is already being used clinically for the assessment of patients with chronic liver diseases and is emerging as a safe, reliable, and noninvasive alternative to liver biopsy for staging hepatic fibrosis. MRE is also being investigated for application to pathologies of other organs including the brain, breast, blood vessels, heart, kidneys, lungs, and skeletal muscle. The purpose of this review article is to introduce this technology to clinical anatomists and to summarize some of the current clinical applications that are being pursued.
Collapse
Affiliation(s)
| | - Kevin J Glaser
- Department of Radiology, Mayo Clinic, Rochester, MN, USA. 55905
| | - Richard L Ehman
- Department of Radiology, Mayo Clinic, Rochester, MN, USA. 55905
| |
Collapse
|
20
|
Youssef A, Ibrahim ESH, Korosoglou G, Abraham MR, Weiss RG, Osman NF. Strain-encoding cardiovascular magnetic resonance for assessment of right-ventricular regional function. J Cardiovasc Magn Reson 2008; 10:33. [PMID: 18601713 PMCID: PMC2478648 DOI: 10.1186/1532-429x-10-33] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2008] [Accepted: 07/04/2008] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Tissue tagging by cardiovascular magnetic resonance (CMR) is a comprehensive method for the assessment of cardiac regional function. However, imaging the right ventricle (RV) using this technique is problematic due to the thin wall of the RV relative to tag spacing which limits assessment of regional function using conventional in-plane tagging. HYPOTHESIS We hypothesize that the use of through-plane tags in the strain-encoding (SENC) CMR technique would result in reproducible measurements of the RV regional function due to the high image quality and spatial resolution possible with SENC. AIM To test the intra- and inter-observer variabilities of RV peak systolic strain measurements with SENC CMR for assessment of RV regional function (systolic strain) in healthy volunteers. METHODS Healthy volunteers (n = 21) were imaged using SENC. A four-chamber view was acquired in a single breath-hold. Circumferential strain was measured during systole at six equidistant points along the RV free wall. Peak contraction is defined as the maximum value of circumferential strain averaged from the six points, and regional function is defined as the strain value at each point at the time of peak contraction. RESULTS Mean values for peak circumferential strain (+/- standard deviation) of the basal, mid, and apical regions of the RV free wall were -20.4 +/- 2.9%, -18.8 +/- 3.9%, and -16.5 +/- 5.7%, Altman plots showed good intra- and inter-observer agreements with mean difference of 0.11% and 0.32% and limits of agreement of -4.038 to 4.174 and -4.903 to 5.836, respectively. CONCLUSION SENC CMR allows for rapid quantification of RV regional function with low intra- and inter-observer variabilities, which could permit accurate quantification of regional strain in patients with RV dysfunction.
Collapse
Affiliation(s)
- Amr Youssef
- Department of Medicine, Division of Cardiology, Johns Hopkins University, Baltimore, MD, USA
- Cardiology department, Ain Shams University, Cairo, Egypt
| | | | - Grigorios Korosoglou
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, MD, USA
- University of Heidelberg, Department of Cardiology, Heidelberg, Germany
| | - M Roselle Abraham
- Department of Medicine, Division of Cardiology, Johns Hopkins University, Baltimore, MD, USA
| | - Robert G Weiss
- Department of Medicine, Division of Cardiology, Johns Hopkins University, Baltimore, MD, USA
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, MD, USA
| | - Nael F Osman
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, MD, USA
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, USA
| |
Collapse
|
21
|
Kozerke S, Plein S. Accelerated CMR using zonal, parallel and prior knowledge driven imaging methods. J Cardiovasc Magn Reson 2008; 10:29. [PMID: 18534005 PMCID: PMC2426690 DOI: 10.1186/1532-429x-10-29] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2008] [Accepted: 06/05/2008] [Indexed: 11/17/2022] Open
Abstract
Accelerated imaging is highly relevant for many CMR applications as competing constraints with respect to spatiotemporal resolution and tolerable scan times are frequently posed. Three approaches, all involving data undersampling to increase scan efficiencies, are discussed in this review. Zonal imaging can be considered a niche but nevertheless has found application in coronary imaging and CMR flow measurements. Current work on parallel-transmit systems is expected to revive the interest in zonal imaging techniques. The second and main approach to speeding up CMR sequences has been parallel imaging. A wide range of CMR applications has benefited from parallel imaging with reduction factors of two to three routinely applied for functional assessment, perfusion, viability and coronary imaging. Large coil arrays, as are becoming increasingly available, are expected to support reduction factors greater than three to four in particular in combination with 3D imaging protocols. Despite these prospects, theoretical work has indicated fundamental limits of coil encoding at clinically available magnetic field strengths. In that respect, alternative approaches exploiting prior knowledge about the object being imaged as such or jointly with parallel imaging have attracted considerable attention. Five to eight-fold scan accelerations in cine and dynamic CMR applications have been reported and image quality has been found to be favorable relative to using parallel imaging alone.With all acceleration techniques, careful consideration of the limits and the trade-off between acceleration and occurrence of artifacts that may arise if these limits are breached is required. In parallel imaging the spatially varying noise has to be considered when measuring contrast- and signal-to-noise ratios. Also, temporal fidelity in images reconstructed with prior knowledge driven methods has to be studied carefully.
Collapse
Affiliation(s)
- Sebastian Kozerke
- Institute for Biomedical Engineering, University of Zurich and Swiss Federal Institute of Technology, Zurich, Switzerland
| | - Sven Plein
- Academic Unit of Cardiovascular Medicine, University of Leeds, Leeds, UK
| |
Collapse
|
22
|
Abd-Elmoniem KZ, Stuber M, Prince JL. Direct three-dimensional myocardial strain tensor quantification and tracking using zHARP. Med Image Anal 2008; 12:778-86. [PMID: 18511332 DOI: 10.1016/j.media.2008.03.008] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2007] [Revised: 02/29/2008] [Accepted: 03/14/2008] [Indexed: 10/22/2022]
Abstract
Images of myocardial strain can be used to diagnose heart disease, plan and monitor treatment, and to learn about cardiac structure and function. Three-dimensional (3D) strain is typically quantified using many magnetic resonance (MR) images obtained in two or three orthogonal planes. Problems with this approach include long scan times, image misregistration, and through-plane motion. This article presents a novel method for calculating cardiac 3D strain using a stack of two or more images acquired in only one orientation. The zHARP pulse sequence encodes in-plane motion using MR tagging and out-of-plane motion using phase encoding, and has been previously shown to be capable of computing 3D displacement within a single image plane. Here, data from two adjacent image planes are combined to yield a 3D strain tensor at each pixel; stacks of zHARP images can be used to derive stacked arrays of 3D strain tensors without imaging multiple orientations and without numerical interpolation. The performance and accuracy of the method is demonstrated in vitro on a phantom and in vivo in four healthy adult human subjects.
Collapse
Affiliation(s)
- Khaled Z Abd-Elmoniem
- Department of Radiology and Radiological Sciences, School of Medicine, Johns Hopkins University, Baltimore, MD 21287, USA.
| | | | | |
Collapse
|
23
|
Fahmy AS, Krieger A, Osman NF. An Integrated System for Real-Time Detection of Stiff Masses With a Single Compression. IEEE Trans Biomed Eng 2006; 53:1286-93. [PMID: 16830933 DOI: 10.1109/tbme.2006.873690] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
An integrated system is proposed for real-time imaging of tissue deformation in response to externally applied mechanical compression. The purpose of the system is to noninvasively detect tissue lesions based on their stiffness. The method includes applying external compression to the examined subject and acquiring magnetic resonance strain-encoded images using a real-time pulse sequence. In the proposed system, only a single compression is necessary to obtain a two-dimensional map of tissue deformation in a slice, eliminating the need for a complicated compressing device. The system was built and validated using phantom experiments.
Collapse
Affiliation(s)
- Ahmed S Fahmy
- Electrical and Computer Engineering Department, The Johns Hopkins University, Baltimore, MD 21218, USA.
| | | | | |
Collapse
|