1
|
Li YY, Zhang P, Rashid S, Cheng YJ, Li W, Schapiro W, Gliganic K, Yamashita AM, Grgas M, Haag E, Cao JJ. Real-time exercise stress cardiac MRI with Fourier-series reconstruction from golden-angle radial data. Magn Reson Imaging 2020; 75:89-99. [PMID: 33098934 DOI: 10.1016/j.mri.2020.10.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Revised: 09/30/2020] [Accepted: 10/18/2020] [Indexed: 10/23/2022]
Abstract
Magnetic resonance imaging (MRI) can measure cardiac response to exercise stress for evaluating and managing heart patients in the practice of clinical cardiology. However, exercise stress cardiac MRI have been clinically limited by the ability of available MRI techniques to quantitatively measure fast and unstable cardiac dynamics during exercise. The presented work is to develop a new real-time MRI technique for improved quantitative performance of exercise stress cardiac MRI. This technique seeks to represent real-time cardiac images as a sparse Fourier-series along the time. With golden-angle radial acquisition, parallel imaging and compressed sensing can be integrated into a linear system of equations for resolving Fourier coefficients that are in turn used to generate real-time cardiac images from the Fourier-series representation. Fourier-series reconstruction from golden-angle radial data can effectively address data insufficiency due to MRI speed limitation, providing a real-time approach to exercise stress cardiac MRI. To demonstrate the feasibility, an exercise stress cardiac MRI experiment was run to investigate biventricular response to in-scanner biking exercise in a cohort of sixteen healthy volunteers. It was found that Fourier-series reconstruction from golden-angle radial data effectively detected exercise-induced increase in stroke volume and ejection fraction in a healthy heart. The presented work will improve the applications of exercise stress cardiac MRI in the practice of clinical cardiology.
Collapse
Affiliation(s)
- Yu Y Li
- St. Francis Hospital, DeMatteis Center for Research and Education, Cardiac Imaging, 101 Northern Blvd, Greenvale, NY 11548, USA.
| | - Pengyue Zhang
- St. Francis Hospital, DeMatteis Center for Research and Education, Cardiac Imaging, 101 Northern Blvd, Greenvale, NY 11548, USA
| | - Shams Rashid
- St. Francis Hospital, DeMatteis Center for Research and Education, Cardiac Imaging, 101 Northern Blvd, Greenvale, NY 11548, USA.
| | - Yang J Cheng
- St. Francis Hospital, DeMatteis Center for Research and Education, Cardiac Imaging, 101 Northern Blvd, Greenvale, NY 11548, USA.
| | - Wenhui Li
- St. Francis Hospital, DeMatteis Center for Research and Education, Cardiac Imaging, 101 Northern Blvd, Greenvale, NY 11548, USA
| | - William Schapiro
- St. Francis Hospital, DeMatteis Center for Research and Education, Cardiac Imaging, 101 Northern Blvd, Greenvale, NY 11548, USA.
| | - Kathleen Gliganic
- St. Francis Hospital, DeMatteis Center for Research and Education, Cardiac Imaging, 101 Northern Blvd, Greenvale, NY 11548, USA.
| | - Ann-Marie Yamashita
- St. Francis Hospital, DeMatteis Center for Research and Education, Cardiac Imaging, 101 Northern Blvd, Greenvale, NY 11548, USA.
| | - Marie Grgas
- St. Francis Hospital, DeMatteis Center for Research and Education, Cardiac Imaging, 101 Northern Blvd, Greenvale, NY 11548, USA.
| | - Elizabeth Haag
- St. Francis Hospital, DeMatteis Center for Research and Education, Cardiac Imaging, 101 Northern Blvd, Greenvale, NY 11548, USA.
| | - J Jane Cao
- St. Francis Hospital, DeMatteis Center for Research and Education, Cardiac Imaging, 101 Northern Blvd, Greenvale, NY 11548, USA.
| |
Collapse
|
2
|
Accelerated real-time cardiac MRI using iterative sparse SENSE reconstruction: comparing performance in patients with sinus rhythm and atrial fibrillation. Eur Radiol 2018; 28:3088-3096. [DOI: 10.1007/s00330-017-5283-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Revised: 12/12/2017] [Accepted: 12/22/2017] [Indexed: 12/19/2022]
|
3
|
Contijoch F, Iyer SK, Pilla JJ, Yushkevich P, Gorman JH, Gorman RC, Litt H, Han Y, Witschey WRT. Self-gated MRI of multiple beat morphologies in the presence of arrhythmias. Magn Reson Med 2016; 78:678-688. [PMID: 27579717 DOI: 10.1002/mrm.26381] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2016] [Revised: 07/01/2016] [Accepted: 07/22/2016] [Indexed: 01/17/2023]
Abstract
PURPOSE Develop self-gated MRI for distinct heartbeat morphologies in subjects with arrhythmias. METHODS Golden angle radial data was obtained in seven sinus and eight arrhythmias subjects. An image-based cardiac navigator was derived from single-shot images, distinct beat types were identified, and images were reconstructed for repeated morphologies. Image sharpness, contrast, and volume variation were quantified and compared with self-gated MRI. Images were scored for image quality and artifacts. Hemodynamic parameters were computed for each distinct beat morphology in bigeminy and trigeminy subjects and for sinus beats in patients with infrequent premature ventricular contractions. RESULTS Images of distinct beat types were reconstructed except for two patients with infrequent premature ventricular contractions. Image contrast and sharpness were similar to sinus self-gated images (contrast = 0.45 ± 0.13 and 0.43 ± 0.15; sharpness = 0.21 ± 0.11 and 0.20 ± 0.05). Visual scoring was highest in self-gated images (4.1 ± 0.3) compared with real-time (3.9 ± 0.4) and ECG-gated cine (3.4 ± 1.5). ECG-gated cine had less artifacts than self-gating (2.3 ± 0.7 and 2.1 ± 0.2), but was affected by misgating in two subjects. Among arrhythmia subjects, post-extrasystole/sinus (58.1 ± 8.6 mL) and interrupted sinus (61.4 ± 5.9 mL) stroke volume was higher than extrasystole (32.0 ± 16.5 mL; P < 0.02). CONCLUSION Self-gated imaging can reconstruct images during ectopy and allowed for quantification of hemodynamic function of different beat morphologies. Magn Reson Med 78:678-688, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Francisco Contijoch
- School of Medicine, University of California - San Diego, San Diego, California, USA
| | - Srikant Kamesh Iyer
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - James J Pilla
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Paul Yushkevich
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Joseph H Gorman
- Department of Surgery, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Robert C Gorman
- Department of Surgery, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Harold Litt
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Yuchi Han
- Department of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Walter R T Witschey
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
4
|
Contijoch F, Witschey WRT, Rogers K, Rears H, Hansen M, Yushkevich P, Gorman J, Gorman RC, Han Y. User-initialized active contour segmentation and golden-angle real-time cardiovascular magnetic resonance enable accurate assessment of LV function in patients with sinus rhythm and arrhythmias. J Cardiovasc Magn Reson 2015; 17:37. [PMID: 25994390 PMCID: PMC4440288 DOI: 10.1186/s12968-015-0146-9] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2014] [Accepted: 05/08/2015] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Data obtained during arrhythmia is retained in real-time cardiovascular magnetic resonance (rt-CMR), but there is limited and inconsistent evidence to show that rt-CMR can accurately assess beat-to-beat variation in left ventricular (LV) function or during an arrhythmia. METHODS Multi-slice, short axis cine and real-time golden-angle radial CMR data was collected in 22 clinical patients (18 in sinus rhythm and 4 patients with arrhythmia). A user-initialized active contour segmentation (ACS) software was validated via comparison to manual segmentation on clinically accepted software. For each image in the 2D acquisitions, slice volume was calculated and global LV volumes were estimated via summation across the LV using multiple slices. Real-time imaging data was reconstructed using different image exposure times and frame rates to evaluate the effect of temporal resolution on measured function in each slice via ACS. Finally, global volumetric function of ectopic and non-ectopic beats was measured using ACS in patients with arrhythmias. RESULTS ACS provides global LV volume measurements that are not significantly different from manual quantification of retrospectively gated cine images in sinus rhythm patients. With an exposure time of 95.2 ms and a frame rate of > 89 frames per second, golden-angle real-time imaging accurately captures hemodynamic function over a range of patient heart rates. In four patients with frequent ectopic contractions, initial quantification of the impact of ectopic beats on hemodynamic function was demonstrated. CONCLUSION User-initialized active contours and golden-angle real-time radial CMR can be used to determine time-varying LV function in patients. These methods will be very useful for the assessment of LV function in patients with frequent arrhythmias.
Collapse
Affiliation(s)
- Francisco Contijoch
- Department of Bioengineering, University of Pennsylvania, Smilow Center for Translational Research, 3400 Civic Center Blvd, Bldg 421, 7th Floor, Rm 103, Philadelphia, PA, 1903, USA.
| | | | - Kelly Rogers
- Cardiovascular Division, Department of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
| | - Hannah Rears
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA.
| | | | - Paul Yushkevich
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA.
| | - Joseph Gorman
- Department of Surgery, University of Pennsylvania, Philadelphia, PA, 1903, USA.
| | - Robert C Gorman
- Department of Surgery, University of Pennsylvania, Philadelphia, PA, 1903, USA.
| | - Yuchi Han
- Cardiovascular Division, Department of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
| |
Collapse
|
5
|
Real-time imaging with radial GRAPPA: Implementation on a heterogeneous architecture for low-latency reconstructions. Magn Reson Imaging 2014; 32:747-58. [PMID: 24690453 DOI: 10.1016/j.mri.2014.02.022] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2013] [Revised: 02/11/2014] [Accepted: 02/14/2014] [Indexed: 11/23/2022]
Abstract
Combination of non-Cartesian trajectories with parallel MRI permits to attain unmatched acceleration rates when compared to traditional Cartesian MRI during real-time imaging. However, computationally demanding reconstructions of such imaging techniques, such as k-space domain radial generalized auto-calibrating partially parallel acquisitions (radial GRAPPA) and image domain conjugate gradient sensitivity encoding (CG-SENSE), lead to longer reconstruction times and unacceptable latency for online real-time MRI on conventional computational hardware. Though CG-SENSE has been shown to work with low-latency using a general purpose graphics processing unit (GPU), to the best of our knowledge, no such effort has been made for radial GRAPPA. Radial GRAPPA reconstruction, which is robust even with highly undersampled acquisitions, is not iterative, requiring only significant computation during initial calibration while achieving good image quality for low-latency imaging applications. In this work, we present a very fast, low-latency, reconstruction framework based on a heterogeneous system using multi-core CPUs and GPUs. We demonstrate an implementation of radial GRAPPA that permits reconstruction times on par with or faster than acquisition of highly accelerated datasets in both cardiac and dynamic musculoskeletal imaging scenarios. Acquisition and reconstruction times are reported.
Collapse
|
6
|
Knoll F, Schultz G, Bredies K, Gallichan D, Zaitsev M, Hennig J, Stollberger R. Reconstruction of undersampled radial PatLoc imaging using total generalized variation. Magn Reson Med 2012; 70:40-52. [PMID: 22847824 DOI: 10.1002/mrm.24426] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2012] [Revised: 06/05/2012] [Accepted: 06/29/2012] [Indexed: 11/11/2022]
Abstract
In the case of radial imaging with nonlinear spatial encoding fields, a prominent star-shaped artifact has been observed if a spin distribution is encoded with an undersampled trajectory. This work presents a new iterative reconstruction method based on the total generalized variation, which reduces this artifact. For this approach, a sampling operator (as well as its adjoint) is needed that maps data from PatLoc k-space to the final image space. It is shown that this can be realized as a type-3 nonuniform fast Fourier transform, which is implemented by a combination of a type-1 and type-2 nonuniform fast Fourier transform. Using this operator, it is also possible to implement an iterative conjugate gradient SENSE based method for PatLoc reconstruction, which leads to a significant reduction of computation time in comparison to conventional PatLoc image reconstruction methods. Results from numerical simulations and in vivo PatLoc measurements with as few as 16 radial projections are presented, which demonstrate significant improvements in image quality with the total generalized variation-based approach.
Collapse
Affiliation(s)
- Florian Knoll
- Institute of Medical Engineering, Graz University of Technology, Kronesgasse 5, A-8010 Graz, Austria.
| | | | | | | | | | | | | |
Collapse
|