Fischer K, Grob L, Setz L, Jung B, Neuenschwander MD, Utz CD, von Tengg-Kobligk H, Huber AT, Friess JO, Guensch DP. Direct comparison of whole heart quantifications between different retrospective and prospective gated 4D flow CMR acquisitions. Front Cardiovasc Med 2024; 11:1411752. [PMID: 39145279 PMCID: PMC11322094 DOI: 10.3389/fcvm.2024.1411752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Accepted: 07/18/2024] [Indexed: 08/16/2024] Open
Abstract
Introduction 4D flow cardiovascular magnetic resonance (CMR) is a versatile technique to non-invasively assess cardiovascular hemodynamics. With developing technology, choice in sequences and acquisition parameters is expanding and it is important to assess if data acquired with these different variants can be directly compared, especially when combining datasets within research studies. For example, sequences may allow a choice in gating techniques or be limited to one method, yet there is not a direct comparison investigating how gating selection impacts quantifications of the great vessels, semilunar and atrioventricular valves and ventricles. Thus, this study investigated if quantifications across the heart from contemporary 4D flow sequences are comparable between two commonly used 4D flow sequences reliant on different ECG gating techniques. Methods Forty participants (33 healthy controls, seven patients with coronary artery disease and abnormal diastolic function) were prospectively recruited into a single-centre observational study to undergo a 3T-CMR exam. Two acquisitions, a k-t GRAPPA 4D flow with prospective gating (4Dprosp) and a modern compressed sensing 4D flow with retrospective gating (4Dretro), were acquired in each participant. Images were analyzed for volumes, flow rates and velocities in the vessels and four valves, and for biventricular kinetic energy and flow components. Data was compared for group differences with paired t-tests and for agreement with Bland-Altman and intraclass correlation (ICC). Results Measurements primarily occurring during systole of the great vessels, semilunar valves and both left and right ventricles did not differ between acquisition types (p > 0.05 from t-test) and yielded good to excellent agreement (ICC: 0.75-0.99). Similar findings were observed for the majority of parameters dependent on early diastole. However, measurements occurring in late diastole or those reliant on the entire-cardiac cycle such as flow component volumes along with diastolic kinetic energy values were not similar between 4Dprosp and 4Dretro acquisitions resulting in poor agreement (ICC < 0.50). Discussion Direct comparison of measurements between two different 4D flow acquisitions reliant on different gating methods demonstrated systolic and early diastolic markers across the heart should be compatible when comparing these two 4D flow sequences. On the other hand, late diastolic and intraventricular parameters should be compared with caution.
Collapse
Affiliation(s)
- Kady Fischer
- Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Leonard Grob
- Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Louis Setz
- Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Bernd Jung
- Department of Diagnostic, Interventional and Paediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
- Translational Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Sitem-Insel, Bern, Switzerland
| | - Mario D. Neuenschwander
- Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Christoph D. Utz
- Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Hendrik von Tengg-Kobligk
- Department of Diagnostic, Interventional and Paediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
- Translational Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Sitem-Insel, Bern, Switzerland
| | - Adrian T. Huber
- Department of Diagnostic, Interventional and Paediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
- Department of Radiology and Nuclear Medicine, Lucerne Cantonal Hospital, University of Lucerne, Lucerne, Switzerland
| | - Jan O. Friess
- Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Dominik P. Guensch
- Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
- Department of Diagnostic, Interventional and Paediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| |
Collapse
|
2
|
Jagadeesan B, Tariq F, Nada A, Bhatti IA, Masood K, Siddiq F. Principles Behind 4D Time-Resolved MRA/Dynamic MRA in Neurovascular Imaging. Semin Roentgenol 2024; 59:191-202. [PMID: 38880517 DOI: 10.1053/j.ro.2024.02.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Accepted: 02/28/2024] [Indexed: 06/18/2024]
Affiliation(s)
- Bharathi Jagadeesan
- Departments of Radiology, Neurology and Neurosurgery, University of Minnesota, Minneapolis, MN.
| | - Farzana Tariq
- Departments of Neurosurgery and Radiology, University of Missouri, Columbia, MO
| | - Ayman Nada
- Departments of Neurosurgery and Radiology, University of Missouri, Columbia, MO
| | - Ibrahim A Bhatti
- Departments of Neurosurgery and Radiology, University of Missouri, Columbia, MO
| | - Kamran Masood
- Departments of Radiology, Neurology and Neurosurgery, University of Minnesota, Minneapolis, MN
| | - Farhan Siddiq
- Departments of Neurosurgery and Radiology, University of Missouri, Columbia, MO
| |
Collapse
|
3
|
Garreau M, Puiseux T, Toupin S, Giese D, Mendez S, Nicoud F, Moreno R. Accelerated sequences of 4D flow MRI using GRAPPA and compressed sensing: A comparison against conventional MRI and computational fluid dynamics. Magn Reson Med 2022; 88:2432-2446. [PMID: 36005271 DOI: 10.1002/mrm.29404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 06/30/2022] [Accepted: 07/14/2022] [Indexed: 01/07/2023]
Abstract
PURPOSE To evaluate hemodynamic markers obtained by accelerated GRAPPA (R = 2, 3, 4) and compressed sensing (R = 7.6) 4D flow MRI sequences under complex flow conditions. METHODS The accelerated 4D flow MRI scans were performed on a pulsatile flow phantom, along with a nonaccelerated fully sampled k-space acquisition. Computational fluid dynamics simulations based on the experimentally measured flow fields were conducted for additional comparison. Voxel-wise comparisons (Bland-Altman analysis, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics> <mml:mrow><mml:msub><mml:mi>L</mml:mi> <mml:mn>2</mml:mn></mml:msub> </mml:mrow> <mml:annotation>$$ {L}_2 $$</mml:annotation></mml:semantics> </mml:math> -norm metric), as well as nonderived quantities (velocity profiles, flow rates, and peak velocities), were used to compare the velocity fields obtained from the different modalities. RESULTS 4D flow acquisitions and computational fluid dynamics depicted similar hemodynamic patterns. Voxel-wise comparisons between the MRI scans highlighted larger discrepancies at the voxels located near the phantom's boundary walls. A trend for all MR scans to overestimate velocity profiles and peak velocities as compared to computational fluid dynamics was noticed in regions associated with high velocity or acceleration. However, good agreement for the flow rates was observed, and eddy-current correction appeared essential for consistency of the flow rates measurements with respect to the principle of mass conservation. CONCLUSION GRAPPA (R = 2, 3) and highly accelerated compressed sensing showed good agreement with the fully sampled acquisition. Yet, all 4D flow MRI scans were hampered by artifacts inherent to the phase-contrast acquisition procedure. Computational fluid dynamics simulations are an interesting tool to assess these differences but are sensitive to modeling parameters.
Collapse
Affiliation(s)
- Morgane Garreau
- University of Montpellier, CNRS, Montpellier, France.,Spin Up, ALARA Group, Strasbourg, France
| | - Thomas Puiseux
- Spin Up, ALARA Group, Strasbourg, France.,I2MC, INSERM/UPS UMR 1297, Toulouse, France
| | | | - Daniel Giese
- Magnetic Resonance, Siemens Healthcare GmbH, Erlangen, Germany
| | - Simon Mendez
- University of Montpellier, CNRS, Montpellier, France
| | - Franck Nicoud
- University of Montpellier, CNRS, Montpellier, France
| | - Ramiro Moreno
- I2MC, INSERM/UPS UMR 1297, Toulouse, France.,ALARA Expertise, ALARA Group, Strasbourg, France
| |
Collapse
|
4
|
Bane O, Stocker D, Kennedy P, Hectors SJ, Bollache E, Schnell S, Schiano T, Thung S, Fischman A, Markl M, Taouli B. 4D flow MRI in abdominal vessels: prospective comparison of k-t accelerated free breathing acquisition to standard respiratory navigator gated acquisition. Sci Rep 2022; 12:19886. [PMID: 36400918 PMCID: PMC9674613 DOI: 10.1038/s41598-022-23864-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Accepted: 11/07/2022] [Indexed: 11/19/2022] Open
Abstract
Volumetric phase-contrast magnetic resonance imaging with three-dimensional velocity encoding (4D flow MRI) has shown utility as a non-invasive tool to examine altered blood flow in chronic liver disease. Novel 4D flow MRI pulse sequences with spatio-temporal acceleration can mitigate the long acquisition times of standard 4D flow MRI, which are an impediment to clinical adoption. The purpose of our study was to demonstrate feasibility of a free-breathing, spatio-temporal (k-t) accelerated 4D flow MRI acquisition for flow quantification in abdominal vessels and to compare its image quality, flow quantification and inter-observer reproducibility with a standard respiratory navigator-gated 4D flow MRI acquisition. Ten prospectively enrolled patients (M/F: 7/3, mean age = 58y) with suspected portal hypertension underwent both 4D flow MRI acquisitions. The k-t accelerated acquisition was approximately three times faster (3:11 min ± 0:12 min/9:17 min ± 1:41 min, p < 0.001) than the standard respiratory-triggered acquisition. Vessel identification agreement was substantial between acquisitions and observers. Average flow had substantial inter-sequence agreement in the portal vein and aorta (CV < 15%) and poorer agreement in hepatic and splenic arteries (CV = 11-38%). The k-t accelerated acquisition recorded reduced velocities in small arteries and reduced splenic vein flow. Respiratory gating combined with increased acceleration and spatial resolution are needed to improve flow measurements in these vessels.
Collapse
Affiliation(s)
- Octavia Bane
- grid.59734.3c0000 0001 0670 2351Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, 1470 Madison Avenue, New York, NY 10029 USA ,grid.59734.3c0000 0001 0670 2351BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY USA
| | - Daniel Stocker
- grid.59734.3c0000 0001 0670 2351Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, 1470 Madison Avenue, New York, NY 10029 USA ,grid.59734.3c0000 0001 0670 2351BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY USA
| | - Paul Kennedy
- grid.59734.3c0000 0001 0670 2351Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, 1470 Madison Avenue, New York, NY 10029 USA ,grid.59734.3c0000 0001 0670 2351BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY USA
| | - Stefanie J. Hectors
- grid.59734.3c0000 0001 0670 2351Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, 1470 Madison Avenue, New York, NY 10029 USA ,grid.59734.3c0000 0001 0670 2351BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY USA
| | - Emilie Bollache
- grid.16753.360000 0001 2299 3507Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL USA ,grid.7429.80000000121866389Laboratoire d’Imagerie Biomédicale, INSERM, Paris, France
| | - Susanne Schnell
- grid.16753.360000 0001 2299 3507Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL USA ,grid.5603.0Department of Medical Physics, Universität Greifswald, Greifswald, Germany
| | - Thomas Schiano
- grid.59734.3c0000 0001 0670 2351Recanati/Miller Transplantation Institute, Icahn School of Medicine at Mount Sinai, New York, NY USA
| | - Swan Thung
- grid.59734.3c0000 0001 0670 2351Department of Pathology, Icahn School of Medicine at Mount Sinai, New York, NY USA
| | - Aaron Fischman
- grid.59734.3c0000 0001 0670 2351Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, 1470 Madison Avenue, New York, NY 10029 USA
| | - Michael Markl
- grid.16753.360000 0001 2299 3507Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL USA ,grid.16753.360000 0001 2299 3507Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL USA
| | - Bachir Taouli
- grid.59734.3c0000 0001 0670 2351Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, 1470 Madison Avenue, New York, NY 10029 USA ,grid.59734.3c0000 0001 0670 2351BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY USA
| |
Collapse
|
5
|
Marlevi D, Mariscal-Harana J, Burris NS, Sotelo J, Ruijsink B, Hadjicharalambous M, Asner L, Sammut E, Chabiniok R, Uribe S, Winter R, Lamata P, Alastruey J, Nordsletten D. Altered Aortic Hemodynamics and Relative Pressure in Patients with Dilated Cardiomyopathy. J Cardiovasc Transl Res 2022; 15:692-707. [PMID: 34882286 PMCID: PMC9622552 DOI: 10.1007/s12265-021-10181-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Accepted: 10/20/2021] [Indexed: 12/05/2022]
Abstract
Ventricular-vascular interaction is central in the adaptation to cardiovascular disease. However, cardiomyopathy patients are predominantly monitored using cardiac biomarkers. The aim of this study is therefore to explore aortic function in dilated cardiomyopathy (DCM). Fourteen idiopathic DCM patients and 16 controls underwent cardiac magnetic resonance imaging, with aortic relative pressure derived using physics-based image processing and a virtual cohort utilized to assess the impact of cardiovascular properties on aortic behaviour. Subjects with reduced left ventricular systolic function had significantly reduced aortic relative pressure, increased aortic stiffness, and significantly delayed time-to-pressure peak duration. From the virtual cohort, aortic stiffness and aortic volumetric size were identified as key determinants of aortic relative pressure. As such, this study shows how advanced flow imaging and aortic hemodynamic evaluation could provide novel insights into the manifestation of DCM, with signs of both altered aortic structure and function derived in DCM using our proposed imaging protocol.
Collapse
Affiliation(s)
- David Marlevi
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Huddinge, Sweden
- Department of Clinical Sciences, Karolinska Institutet, Danderyd, Sweden
| | - Jorge Mariscal-Harana
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | | | - Julio Sotelo
- School of Biomedical Engineering, Universidad de Valparaíso, Valparaíso, Chile
- Biomedical Imaging Center, Pontificia Universidad Catolica de Chile, Santiago, Chile
- Millennium Nucleus in Cardiovascular Magnetic Resonance, Santiago, Cardio MR, Chile
| | - Bram Ruijsink
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Myrianthi Hadjicharalambous
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Department of Mechanical and Manufacturing Engineering, University of Cyprus, Nicosia, Cyprus
| | - Liya Asner
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Eva Sammut
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Faculty of Health Science, Bristol Heart Institute and Translational Biomedical Research Centre, University of Bristol, Bristol, UK
| | - Radomir Chabiniok
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Inria, Palaiseau, France
- LMS, Ecole Polytechnique, CNRS, Institut Polytechnique de Paris, Paris, France
- Department of Mathematics, Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, , Prague, Czech Republic
| | - Sergio Uribe
- Biomedical Imaging Center, Pontificia Universidad Catolica de Chile, Santiago, Chile
- Millennium Nucleus in Cardiovascular Magnetic Resonance, Santiago, Cardio MR, Chile
- Department of Radiology, School of Medicine, Pontifica Universidad Católica de Chile, Santiago, Chile
| | - Reidar Winter
- Department of Clinical Sciences, Karolinska Institutet, Danderyd, Sweden
| | - Pablo Lamata
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Jordi Alastruey
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- World-Class Research Center "Digital Biodesign and Personlized Healthcare", Sechenov University, Moscow, Russia
| | - David Nordsletten
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
- Department of Cardiac Surgery and Biomedical Engineering, University of Michigan, Plymouth Rd, Ann Arbor, MI, 48109, USA.
| |
Collapse
|
6
|
Terada M, Takehara Y, Isoda H, Wakayama T, Nozaki A. Technical Background for 4D Flow MR Imaging. Magn Reson Med Sci 2022; 21:267-277. [PMID: 35153275 PMCID: PMC9680548 DOI: 10.2463/mrms.rev.2021-0104] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Accepted: 11/20/2021] [Indexed: 10/27/2023] Open
Abstract
Recently, the hemodynamic assessments with 3D cine phase-contrast (PC) MRI (4D flow MRI) have attracted considerable attention from clinicians. Unlike 2D cine PC MRI, the technique allows for cardiac phase-resolved data acquisitions of flow velocity vectors within the entire FOV during a clinically viable period. Thus, the method has enabled retrospective flowmetry in the spatial and temporal axes, which are essential to derive hemodynamic parameters related to vascular homeostasis and those to the progression of the pathologies. Accelerations in imaging are critical for this technology to be clinically viable; however, a high SNR or velocity-to-noise ratio (VNR) is also vital for accurate flow measurements. In this chapter, the technologies enabling this difficult balance are discussed.
Collapse
Affiliation(s)
- Masaki Terada
- Department of Diagnostic Radiologic Technology, Iwata City Hospital, Iwata, Shizuoka, Japan
| | - Yasuo Takehara
- Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Haruo Isoda
- Department of Brain & Mind Sciences, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | | | - Atsushi Nozaki
- MR Applications and Workflow, GE Healthcare Japan, Tokyo, Japan
| |
Collapse
|
7
|
Strecker C, Krafft AJ, Kaufhold L, Hüllebrandt M, Treppner M, Ludwig U, Köber G, Hennemuth A, Hennig J, Harloff A. Carotid Geometry and Wall Shear Stress Independently Predict Increased Wall Thickness-A Longitudinal 3D MRI Study in High-Risk Patients. Front Cardiovasc Med 2021; 8:723860. [PMID: 34765650 PMCID: PMC8576112 DOI: 10.3389/fcvm.2021.723860] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Accepted: 09/27/2021] [Indexed: 11/13/2022] Open
Abstract
Introduction: Carotid geometry and wall shear stress (WSS) have been proposed as independent risk factors for the progression of carotid atherosclerosis, but this has not yet been demonstrated in larger longitudinal studies. Therefore, we investigated the impact of these biomarkers on carotid wall thickness in patients with high cardiovascular risk. Methods: Ninety-seven consecutive patients with hypertension, at least one additional cardiovascular risk factor and internal carotid artery (ICA) plaques (wall thickness ≥ 1.5 mm and degree of stenosis ≤ 50%) were prospectively included. They underwent high-resolution 3D multi-contrast and 4D flow MRI at 3 Tesla both at baseline and follow-up. Geometry (ICA/common carotid artery (CCA)-diameter ratio, bifurcation angle, tortuosity and wall thickness) and hemodynamics [WSS, oscillatory shear index (OSI)] of both carotid bifurcations were measured at baseline. Their predictive value for changes of wall thickness 12 months later was calculated using linear regression analysis for the entire study cohort (group 1, 97 patients) and after excluding patients with ICA stenosis ≥10% to rule out relevant inward remodeling (group 2, 61 patients). Results: In group 1, only tortuosity at baseline was independently associated with carotid wall thickness at follow-up (regression coefficient = −0.52, p < 0.001). However, after excluding patients with ICA stenosis ≥10% in group 2, both ICA/CCA-ratio (0.49, p < 0.001), bifurcation angle (0.04, p = 0.001), tortuosity (−0.30, p = 0.040), and WSS (−0.03, p = 0.010) at baseline were independently associated with changes of carotid wall thickness at follow-up. Conclusions: A large ICA bulb and bifurcation angle and low WSS seem to be independent risk factors for the progression of carotid atherosclerosis in the absence of ICA stenosis. By contrast, a high carotid tortuosity seems to be protective both in patients without and with ICA stenosis. These biomarkers may be helpful for the identification of patients who are at particular risk of wall thickness progression and who may benefit from intensified monitoring and treatment.
Collapse
Affiliation(s)
- Christoph Strecker
- Department of Neurology and Neurophysiology, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Axel Joachim Krafft
- Department of Radiology-Medical Physics, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Lilli Kaufhold
- Fraunhofer MEVIS, Bremen, Germany.,Institute for Imaging Science and Computational Modeling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Markus Hüllebrandt
- Fraunhofer MEVIS, Bremen, Germany.,Institute for Imaging Science and Computational Modeling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Martin Treppner
- Institute of Medical Biometry and Statistics, Faculty of Medicine and Medical Center, University of Freiburg, Freiburg, Germany
| | - Ute Ludwig
- Department of Radiology-Medical Physics, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Göran Köber
- Institute of Medical Biometry and Statistics, Faculty of Medicine and Medical Center, University of Freiburg, Freiburg, Germany
| | - Anja Hennemuth
- Fraunhofer MEVIS, Bremen, Germany.,Institute for Imaging Science and Computational Modeling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Jürgen Hennig
- Department of Radiology-Medical Physics, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Andreas Harloff
- Department of Neurology and Neurophysiology, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| |
Collapse
|
8
|
Zhuang B, Sirajuddin A, Zhao S, Lu M. The role of 4D flow MRI for clinical applications in cardiovascular disease: current status and future perspectives. Quant Imaging Med Surg 2021; 11:4193-4210. [PMID: 34476199 DOI: 10.21037/qims-20-1234] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 04/23/2021] [Indexed: 11/06/2022]
Abstract
Magnetic resonance imaging (MRI) four-dimensional (4D) flow is a type of phase-contrast (PC) MRI that uses blood flow encoded in 3 directions, which is resolved relative to 3 spatial and temporal dimensions of cardiac circulation. It can be used to simultaneously quantify and visualize hemodynamics or morphology disorders. 4D flow MRI is more comprehensive and accurate than two-dimensional (2D) PC MRI and echocardiography. 4D flow MRI provides numerous hemodynamic parameters that are not limited to the basic 2D parameters, including wall shear stress (WSS), pulse wave velocity (PWV), kinetic energy, turbulent kinetic energy (TKE), pressure gradient, and flow component analysis. 4D flow MRI is widely used to image many parts of the body, such as the neck, brain, and liver, and has a wide application spectrum to cardiac diseases and large vessels. This present review aims to summarize the hemodynamic parameters of 4D flow MRI technology and generalize their usefulness in clinical practice in relation to the cardiovascular system. In addition, we note the improvements that have been made to 4D flow MRI with the application of new technologies. The application of new technologies can improve the speed of 4D flow, which would benefit clinical applications.
Collapse
Affiliation(s)
- Baiyan Zhuang
- Department of Magnetic Resonance Imaging, Fuwai Hospital, State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Arlene Sirajuddin
- National Heart, Lung and Blood Institute (NHLBI), National Institutes of Health (NIH), Bethesda, MD, USA
| | - Shihua Zhao
- Department of Magnetic Resonance Imaging, Fuwai Hospital, State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Minjie Lu
- Department of Magnetic Resonance Imaging, Fuwai Hospital, State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.,Key Laboratory of Cardiovascular Imaging (Cultivation), Chinese Academy of Medical Sciences, Beijing, China
| |
Collapse
|
9
|
Morgan AG, Thrippleton MJ, Wardlaw JM, Marshall I. 4D flow MRI for non-invasive measurement of blood flow in the brain: A systematic review. J Cereb Blood Flow Metab 2021; 41:206-218. [PMID: 32936731 PMCID: PMC8369999 DOI: 10.1177/0271678x20952014] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Revised: 06/22/2020] [Accepted: 07/05/2020] [Indexed: 01/25/2023]
Abstract
The brain's vasculature is essential for brain health and its dysfunction contributes to the onset and development of many dementias and neurological disorders. While numerous in vivo imaging techniques exist to investigate cerebral haemodynamics in humans, phase-contrast magnetic resonance imaging (MRI) has emerged as a reliable, non-invasive method of quantifying blood flow within intracranial vessels. In recent years, an advanced form of this method, known as 4D flow, has been developed and utilised in patient studies, where its ability to capture complex blood flow dynamics within any major vessel across the acquired volume has proved effective in collecting large amounts of information in a single scan. While extremely promising as a method of examining the vascular system's role in brain-related diseases, the collection of 4D data can be time-consuming, meaning data quality has to be traded off against the acquisition time. Here, we review the available literature to examine 4D flow's capabilities in assessing physiological and pathological features of the cerebrovascular system. Emerging techniques such as dynamic velocity-encoding and advanced undersampling methods, combined with increasingly high-field MRI scanners, are likely to bring 4D flow to the forefront of cerebrovascular imaging studies in the years to come.
Collapse
Affiliation(s)
- Alasdair G Morgan
- Brain Research Imaging Centre, Centre for Clinical Brain
Sciences, University of Edinburgh, Edinburgh, UK
- UK Dementia Research Institute at The University of Edinburgh,
Edinburgh Medical School, Edinburgh, UK
| | - Michael J Thrippleton
- Brain Research Imaging Centre, Centre for Clinical Brain
Sciences, University of Edinburgh, Edinburgh, UK
- UK Dementia Research Institute at The University of Edinburgh,
Edinburgh Medical School, Edinburgh, UK
| | - Joanna M Wardlaw
- Brain Research Imaging Centre, Centre for Clinical Brain
Sciences, University of Edinburgh, Edinburgh, UK
- UK Dementia Research Institute at The University of Edinburgh,
Edinburgh Medical School, Edinburgh, UK
- Centre for Cognitive Ageing and Cognitive Epidemiology,
University of Edinburgh, Edinburgh, UK
| | - Ian Marshall
- Brain Research Imaging Centre, Centre for Clinical Brain
Sciences, University of Edinburgh, Edinburgh, UK
- UK Dementia Research Institute at The University of Edinburgh,
Edinburgh Medical School, Edinburgh, UK
| |
Collapse
|
10
|
Settecase F, Rayz VL. Advanced vascular imaging techniques. HANDBOOK OF CLINICAL NEUROLOGY 2021; 176:81-105. [DOI: 10.1016/b978-0-444-64034-5.00016-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
11
|
Non-invasive estimation of relative pressure for intracardiac flows using virtual work-energy. Med Image Anal 2020; 68:101948. [PMID: 33383332 DOI: 10.1016/j.media.2020.101948] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 12/10/2020] [Accepted: 12/11/2020] [Indexed: 01/18/2023]
Abstract
Intracardiac blood flow is driven by differences in relative pressure, and assessing these is critical in understanding cardiac disease. Non-invasive image-based methods exist to assess relative pressure, however, the complex flow and dynamically moving fluid domain of the intracardiac space limits assessment. Recently, we proposed a method, νWERP, utilizing an auxiliary virtual field to probe relative pressure through complex, and previously inaccessible flow domains. Here we present an extension of νWERP for intracardiac flow assessments, solving the virtual field over sub-domains to effectively handle the dynamically shifting flow domain. The extended νWERP is validated in an in-silico benchmark problem, as well as in a patient-specific simulation model of the left heart, proving accurate over ranges of realistic image resolutions and noise levels, as well as superior to alternative approaches. Lastly, the extended νWERP is applied on clinically acquired 4D Flow MRI data, exhibiting realistic ventricular relative pressure patterns, as well as indicating signs of diastolic dysfunction in an exemplifying patient case. Summarized, the extended νWERP approach represents a directly applicable implementation for intracardiac flow assessments.
Collapse
|
12
|
Youn SW, Lee J. From 2D to 4D Phase-Contrast MRI in the Neurovascular System: Will It Be a Quantum Jump or a Fancy Decoration? J Magn Reson Imaging 2020; 55:347-372. [PMID: 33236488 DOI: 10.1002/jmri.27430] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Revised: 10/20/2020] [Accepted: 10/21/2020] [Indexed: 12/16/2022] Open
Abstract
Considering the crosstalk between the flow and vessel wall, hemodynamic assessment of the neurovascular system may offer a well-integrated solution for both diagnosis and management by adding prognostic significance to the standard CT/MR angiography. 4D flow MRI or time-resolved 3D velocity-encoded phase-contrast MRI has long been promising for the hemodynamic evaluation of the great vessels, but challenged in clinical studies for assessing intracranial vessels with small diameter due to long scan times and low spatiotemporal resolution. Current accelerated MRI techniques, including parallel imaging with compressed sensing and radial k-space undersampling acquisitions, have decreased scan times dramatically while preserving spatial resolution. 4D flow MRI visualized and measured 3D complex flow of neurovascular diseases such as aneurysm, arteriovenous shunts, and atherosclerotic stenosis using parameters including flow volume, velocity vector, pressure gradients, and wall shear stress. In addition to the noninvasiveness of the phase contrast technique and retrospective flow measurement through the wanted windows of the analysis plane, 4D flow MRI has shown several advantages over Doppler ultrasound or computational fluid dynamics. The evaluation of the flow status and vessel wall can be performed simultaneously in the same imaging modality. This article is an overview of the recent advances in neurovascular 4D flow MRI techniques and their potential clinical applications in neurovascular disease. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY STAGE: 3.
Collapse
Affiliation(s)
- Sung Won Youn
- Department of Radiology, Catholic University of Daegu School of Medicine, Daegu, Korea
| | - Jongmin Lee
- Department of Radiology and Biomedical Engineering, Kyungpook National University School of Medicine, Daegu, Korea
| |
Collapse
|
13
|
Santini F, Pansini M, Hrabak-Paar M, Yates D, Langenickel TH, Bremerich J, Bieri O, Schubert T. On the optimal temporal resolution for phase contrast cardiovascular magnetic resonance imaging: establishment of baseline values. J Cardiovasc Magn Reson 2020; 22:72. [PMID: 33012283 PMCID: PMC7534161 DOI: 10.1186/s12968-020-00669-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Accepted: 09/08/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The aim of this study is to quantify the frequency content of the blood velocity waveform in different body regions by means of phase contrast (PC) cardiovascular magnetic resonance (CMR) and Doppler ultrasound. The highest frequency component of the spectrum is inversely proportional to the ideal temporal resolution to be used for the acquisition of flow-sensitive imaging (Shannon-Nyquist theorem). METHODS Ten healthy subjects (median age 33y, range 24-40) were scanned with a high-temporal-resolution PC-CMR and with Doppler ultrasound on three body regions (carotid arteries, aorta and femoral arteries). Furthermore, 111 patients (median age 61y) with mild to moderate arterial hypertension and 58 patients with aortic aregurgitation, atrial septal defect, or repaired tetralogy of Fallot underwent aortic CMR scanning. The frequency power distribution was calculated for each location and the maximum frequency component, fmax, was extracted and expected limits for the general population were inferred. RESULTS In the healthy subject cohort, significantly different fmax values were found across the different body locations, but they were nonsignificant across modalities. No significant correlation was found with heart rate. The measured fmax ranged from 7.7 ± 1.1 Hz in the ascending aorta, up to 12.3 ± 5.1 Hz in the femoral artery (considering PC-CMR data). The calculated upper boundary for the general population ranged from 11.0 Hz to 27.5 Hz, corresponding to optimal temporal resolutions of 45 ms and 18 ms, respectively. The patient cohort exhibited similar values for the frequencies in the aorta, with no correlation between blood pressure and frequency content. CONCLUSIONS The temporal resolution of PC-CMR acquisitions can be adapted based on the scanned body region and in the adult population, should approach approximately 20 ms in the peripheral arteries and 40 ms in the aorta. TRIAL REGISTRATION This study presents results from a restrospective analysis of the clinical study NCT01870739 (ClinicalTrials.gov).
Collapse
Affiliation(s)
- Francesco Santini
- Department of Radiology, Division of Radiological Physics, University Hospital Basel, Petersgraben 4, 4031, Basel, Switzerland.
- Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland.
| | | | - Maja Hrabak-Paar
- University Hospital Center Zagreb, University of Zagreb School of Medicine, Zagreb, Croatia
| | - Denise Yates
- Novartis Institutes of Biomedical Research, Cambridge, MA, USA
| | - Thomas H Langenickel
- Novartis Institutes for Biomedical Research, Translational Medicine, Basel, Switzerland
- Ethris GmbH, Planegg, Germany
| | - Jens Bremerich
- Department of Radiology, University Hospital Basel, Basel, Switzerland
| | - Oliver Bieri
- Department of Radiology, Division of Radiological Physics, University Hospital Basel, Petersgraben 4, 4031, Basel, Switzerland
- Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland
| | - Tilman Schubert
- Department of Neuroradiology, Zurich University Hospital, Zurich, Switzerland
| |
Collapse
|
14
|
Strecker C, Krafft AJ, Kaufhold L, Hüllebrandt M, Weber S, Ludwig U, Wolkewitz M, Hennemuth A, Hennig J, Harloff A. Carotid geometry is an independent predictor of wall thickness - a 3D cardiovascular magnetic resonance study in patients with high cardiovascular risk. J Cardiovasc Magn Reson 2020; 22:67. [PMID: 32912285 PMCID: PMC7488078 DOI: 10.1186/s12968-020-00657-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Accepted: 07/28/2020] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND The posterior wall of the proximal internal carotid artery (ICA) is the predilection site for the development of stenosis. To optimally prevent stroke, identification of new risk factors for plaque progression is of high interest. Therefore, we studied the impact of carotid geometry and wall shear stress on cardiovascular magnetic resonance (CMR)-depicted wall thickness in the ICA of patients with high cardiovascular disease risk. METHODS One hundred twenty-one consecutive patients ≥50 years with hypertension, ≥1 additional cardiovascular risk factor and ICA plaque ≥1.5 mm thickness and < 50% stenosis were prospectively included. High-resolution 3D-multi-contrast (time of flight, T1, T2, proton density) and 4D flow CMR were performed for the assessment of morphological (bifurcation angle, ICA/common carotid artery (CCA) diameter ratio, tortuosity, and wall thickness) and hemodynamic parameters (absolute/systolic wall shear stress (WSS), oscillatory shear index (OSI)) in 242 carotid bifurcations. RESULTS We found lower absolute/systolic WSS, higher OSI and increased wall thickness in the posterior compared to the anterior wall of the ICA bulb (p < 0.001), whereas this correlation disappeared in ≥10% stenosis. Higher carotid tortuosity (regression coefficient = 0.764; p < 0.001) and lower ICA/CCA diameter ratio (regression coefficient = - 0.302; p < 0.001) were independent predictors of increased wall thickness even after adjustment for cardiovascular risk factors. This association was not found for bifurcation angle, WSS or OSI in multivariate regression analysis. CONCLUSIONS High carotid tortuosity and low ICA diameter were independent predictors for wall thickness of the ICA bulb in this cross-sectional study, whereas this association was not present for WSS or OSI. Thus, consideration of geometric parameters of the carotid bifurcation could be helpful to identify patients at increased risk of carotid plaque generation. However, this association and the potential benefit of WSS measurement need to be further explored in a longitudinal study.
Collapse
Affiliation(s)
- Christoph Strecker
- Department of Neurology and Neurophysiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacherstrasse 64, 79106 Freiburg, Germany
| | - Axel Joachim Krafft
- Department of Radiology - Medical Physics, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Lilli Kaufhold
- Fraunhofer MEVIS, Bremen, Germany
- Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Markus Hüllebrandt
- Fraunhofer MEVIS, Bremen, Germany
- Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Susanne Weber
- Institute of Medical Biometry and Statistics, Faculty of Medicine and Medical Center, University of Freiburg, Freiburg, Germany
| | - Ute Ludwig
- Department of Radiology - Medical Physics, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Martin Wolkewitz
- Institute of Medical Biometry and Statistics, Faculty of Medicine and Medical Center, University of Freiburg, Freiburg, Germany
| | - Anja Hennemuth
- Fraunhofer MEVIS, Bremen, Germany
- Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Jürgen Hennig
- Department of Radiology - Medical Physics, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Andreas Harloff
- Department of Neurology and Neurophysiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacherstrasse 64, 79106 Freiburg, Germany
| |
Collapse
|
15
|
Jaeger E, Sonnabend K, Schaarschmidt F, Maintz D, Weiss K, Bunck AC. Compressed-sensing accelerated 4D flow MRI of cerebrospinal fluid dynamics. Fluids Barriers CNS 2020; 17:43. [PMID: 32677977 PMCID: PMC7364783 DOI: 10.1186/s12987-020-00206-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Accepted: 07/06/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND 4D flow magnetic resonance imaging (MRI) of CSF can make an important contribution to the understanding of hydrodynamic changes in various neurological diseases but remains limited in clinical application due to long acquisition times. The aim of this study was to evaluate the accuracy of compressed SENSE accelerated MRI measurements of the spinal CSF flow. METHODS In 20 healthy subjects 4D flow MRI of the CSF in the cervical spine was acquired using compressed sensitivity encoding [CSE, a combination of compressed sensing and parallel imaging (SENSE) provided by the manufacturer] with acceleration factors between 4 and 10. A conventional scan using SENSE was used as reference. Extracted parameters were peak velocity, absolute net flow, forward flow and backward flow. Bland-Altman analysis was performed to determine the scan-rescan reproducibility and the agreement between SENSE and compressed SENSE. Additionally, a time accumulated flow error was calculated. In one additional subject flow of the spinal canal at the level of the entire spinal cord was assessed. RESULTS Averaged acquisition times were 10:21 min (SENSE), 9:31 min (CSE4), 6:25 min (CSE6), 4:53 min (CSE8) and 3:51 min (CSE10). Acquisition of the CSF flow surrounding the entire spinal cord took 14:40 min. Bland-Altman analysis showed good agreement for peak velocity, but slight overestimations for absolute net flow, forward flow and backward flow (< 1 ml/min) in CSE4-8. Results of the accumulated flow error were similar for CSE4 to CSE8. CONCLUSION A quantitative analysis of acceleration factors CSE4-10 showed that CSE with an acceleration factor up to 6 is feasible. This allows a scan time reduction of 40% and enables the acquisition and analysis of the CSF flow dynamics surrounding the entire spinal cord within a clinically acceptable scan time.
Collapse
Affiliation(s)
- Elena Jaeger
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - Kristina Sonnabend
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany.
| | - Frank Schaarschmidt
- Institute of Cell Biology and Biophysics, Biostatistics Department, Leibniz University Hannover, Hannover, Germany
| | - David Maintz
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - Kilian Weiss
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany.,Philips GmbH, Hamburg, Germany
| | - Alexander C Bunck
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| |
Collapse
|
16
|
Neuhaus E, Weiss K, Bastkowski R, Koopmann J, Maintz D, Giese D. Accelerated aortic 4D flow cardiovascular magnetic resonance using compressed sensing: applicability, validation and clinical integration. J Cardiovasc Magn Reson 2019; 21:65. [PMID: 31638997 PMCID: PMC6802342 DOI: 10.1186/s12968-019-0573-0] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Accepted: 08/29/2019] [Indexed: 01/29/2023] Open
Abstract
BACKGROUND Three-dimensional time-resolved phase-contrast cardiovascular magnetic resonance (4D flow CMR) enables the quantification and visualisation of blood flow, but its clinical applicability remains hampered by its long scan time. The aim of this study was to evaluate the use of compressed sensing (CS) with on-line reconstruction to accelerate the acquisition and reconstruction of 4D flow CMR of the thoracic aorta. METHODS 4D flow CMR of the thoracic aorta was acquired in 20 healthy subjects using CS with acceleration factors ranging from 4 to 10. As a reference, conventional parallel imaging (SENSE) with acceleration factor 2 was used. Flow curves, net flows, peak flows and peak velocities were extracted from six contours along the aorta. To measure internal data consistency, a quantitative particle trace analysis was performed. Additionally, scan-rescan, inter- and intraobserver reproducibility were assessed. Subsequently, 4D flow CMR with CS factor 6 was acquired in 3 patients with differing aortopathies. The flow patterns resulting from particle trace visualisation were qualitatively analysed. RESULTS All collected data were successfully acquired and reconstructed on-line. The average acquisition time including respiratory navigator efficiency with CS factor 6 was 5:02 ± 2:23 min while reconstruction took approximately 9 min. For CS factors of 8 or less, mean differences in net flow, peak flow and peak velocity as compared to SENSE were below 2.2 ± 7.8 ml/cycle, 4.6 ± 25.2 ml/s and - 7.9 ± 13.0 cm/s, respectively. For a CS factor of 10 differences reached 5.4 ± 8.0 ml/cycle, 14.4 ± 28.3 ml/s and - 4.0 ± 12.2 cm/s. Scan-rescan analysis yielded mean differences in net flow of - 0.7 ± 4.9 ml/cycle for SENSE and - 0.2 ± 8.5 ml/cycle for CS factor of 6. CONCLUSIONS A six- to eightfold acceleration of 4D flow CMR using CS is feasible. Up to a CS acceleration rate of 6, no statistically significant differences in measured flow parameters could be observed with respect to the reference technique. Acquisitions in patients with aortopathies confirm the potential to integrate the proposed method in a clinical routine setting, whereby its main benefits are scan-time savings and direct on-line reconstruction.
Collapse
Affiliation(s)
- Elisabeth Neuhaus
- Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Kilian Weiss
- Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
- Philips GmbH, Hamburg, Germany
| | - Rene Bastkowski
- Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Jonas Koopmann
- Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - David Maintz
- Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Daniel Giese
- Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| |
Collapse
|
17
|
Bastkowski R, Bindermann R, Brockmeier K, Weiss K, Maintz D, Giese D. Respiration Dependency of Caval Blood Flow in Patients with Fontan Circulation: Quantification Using 5D Flow MRI. Radiol Cardiothorac Imaging 2019; 1:e190005. [PMID: 33778515 PMCID: PMC7977808 DOI: 10.1148/ryct.2019190005] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Revised: 06/26/2019] [Accepted: 07/30/2019] [Indexed: 06/12/2023]
Abstract
PURPOSE To measure respiration-dependent blood flow in the total cavopulmonary connection (TCPC) of patients with Fontan circulation by using free-running, fully self-gated five-dimensional (5D) flow MRI. MATERIALS AND METHODS From July to November 2018, 10 volunteers (six female volunteers, mean age, 25.1 years ± 4.4 [standard deviation]) and six patients with Fontan circulation (two female patients, mean age, 19.7 years ± 7.5) with a TCPC were examined by using a cardiac- and respiration-resolved three-directional and three-dimensional phase-contrast MRI sequence (hereafter, 5D flow MRI). This prospective study was conducted with approval of the local ethics committee, and written informed consent was obtained from all participants and/or their representative. 5D flow data were acquired during free breathing. Data were reconstructed into 15-20 heart phases and four respiratory phases: end-expiration, inspiration, end-inspiration, and expiration. Respiration-dependent stroke volumes (SVs) and particle traces were analyzed from the caval circulation of volunteers and patients with Fontan circulation. Statistical analysis was performed by using parametric tests and scatterplots. RESULTS The respiration dependency of caval blood flow was evaluated in all participants and was significantly elevated in patients with Fontan circulation as compared with volunteers. In patients, SV in the inferior vena cava (IVC) showed variations of 120% between inspiration and expiration (P = .002). The flow distribution in the IVC and superior vena cava among the four respiratory phases was differentiated by 20% (range, 9%-30%) and 4% (range, 0%-13%), respectively. CONCLUSION Hemodynamic parameters (volume flow and blood flow distribution) throughout the cardiac and respiratory cycle can be measured using a single scan, potentially providing further insights into the Fontan circulation.© RSNA, 2019Supplemental material is available for this article.
Collapse
|
18
|
Ebel S, Dufke J, Köhler B, Preim B, Rosemeier S, Jung B, Dähnert I, Lurz P, Borger M, Grothoff M, Gutberlet M. Comparison of two accelerated 4D-flow sequences for aortic flow quantification. Sci Rep 2019; 9:8643. [PMID: 31201339 PMCID: PMC6572772 DOI: 10.1038/s41598-019-45196-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Accepted: 05/30/2019] [Indexed: 01/26/2023] Open
Abstract
To compare two broadly used 4D-flow- with a 2D-flow-sequence in healthy volunteers, regarding absolute flow parameters, image quality (IQ), and eddy current correction (ECC). Forty volunteers (42 ± 11.8 years, 22 females) were examined with a 3T scanner. Thoracic aortic flow was assessed using a 3D-T2w-SPACE-STIR-sequence for morphology and two accelerated 4D-flow sequences for comparison, one with k-t undersampling and one with standard GRAPPA parallel-imaging. 2D-flow was used as reference standard. The custom-made software tool Bloodline enabled flow measurements for all analyses at the same location. Quantitative flow analyses were performed with and without ECC. One reader assessed pathline IQ (IQ-PATH) and occurrence of motion artefacts (IQ-ART) on a 3-point grading scale, the higher the better. k-t GRAPPA allowed a significant mean scan time reduction of 46% (17:56 ± 5:26 min vs. 10:40 ± 3:15 min) and provided significantly fewer motion artefacts than standard GRAPPA (IQ-ART 1.57 ± 0.55 vs. 0.84 ± 0.48; p < 0.001). Neither 4D-flow sequence significantly differed in flow volume nor peak velocity results with or without ECC. Nevertheless, the correlation between both 4D-flow sequences and 2D-flow was better with ECC; the k-t GRAPPA sequence performed best (R = 0.96 vs. 0.90). k-t GRAPPA 4D-flow was not inferior to a standard GRAPPA-sequence, showed fewer artefacts, comparable IQ and was almost two-fold faster.
Collapse
Affiliation(s)
- Sebastian Ebel
- Department of Diagnostic and Interventional Radiology, University of Leipzig - Heart Centre, Leipzig, Germany.
| | - Josefin Dufke
- Department of Diagnostic and Interventional Radiology, University of Leipzig - Heart Centre, Leipzig, Germany
| | - Benjamin Köhler
- Department of Simulation and Graphics, University of Magdeburg, Magdeburg, Germany
| | - Bernhard Preim
- Department of Simulation and Graphics, University of Magdeburg, Magdeburg, Germany
| | - Susan Rosemeier
- Department of Diagnostic and Interventional Radiology, University of Leipzig - Heart Centre, Leipzig, Germany
| | - Bernd Jung
- Department of Diagnostic, Interventional and Paediatric Radiology, University of Bern, Bern, Switzerland
| | - Ingo Dähnert
- Department of Paediatric Cardiology, University of Leipzig - Heart Centre, Leipzig, Germany
| | - Philipp Lurz
- Department of Cardiology, University of Leipzig - Heart Centre, Leipzig, Germany
| | - Michael Borger
- Department of Cardiac Surgery, University of Leipzig - Heart Centre, Leipzig, Germany
| | - Matthias Grothoff
- Department of Diagnostic and Interventional Radiology, University of Leipzig - Heart Centre, Leipzig, Germany
| | - Matthias Gutberlet
- Department of Diagnostic and Interventional Radiology, University of Leipzig - Heart Centre, Leipzig, Germany
| |
Collapse
|
19
|
Ye JC. Compressed sensing MRI: a review from signal processing perspective. BMC Biomed Eng 2019; 1:8. [PMID: 32903346 PMCID: PMC7412677 DOI: 10.1186/s42490-019-0006-z] [Citation(s) in RCA: 62] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2018] [Accepted: 02/04/2019] [Indexed: 11/27/2022] Open
Abstract
Magnetic resonance imaging (MRI) is an inherently slow imaging modality, since it acquires multi-dimensional k-space data through 1-D free induction decay or echo signals. This often limits the use of MRI, especially for high resolution or dynamic imaging. Accordingly, many investigators has developed various acceleration techniques to allow fast MR imaging. For the last two decades, one of the most important breakthroughs in this direction is the introduction of compressed sensing (CS) that allows accurate reconstruction from sparsely sampled k-space data. The recent FDA approval of compressed sensing products for clinical scans clearly reflect the maturity of this technology. Therefore, this paper reviews the basic idea of CS and how this technology have been evolved for various MR imaging problems.
Collapse
Affiliation(s)
- Jong Chul Ye
- Department of Bio and Brain Engineering, Korea Adv. Inst. of Science & Technology (KAIST), 291 Daehak-ro, Daejeon, Korea
| |
Collapse
|
20
|
Ebel S, Hübner L, Köhler B, Kropf S, Preim B, Jung B, Grothoff M, Gutberlet M. Validation of two accelerated 4D flow MRI sequences at 3 T: a phantom study. Eur Radiol Exp 2019; 3:10. [PMID: 30806827 PMCID: PMC6391502 DOI: 10.1186/s41747-019-0089-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Accepted: 02/01/2019] [Indexed: 12/15/2022] Open
Abstract
Background Four-dimensional (4D) flow magnetic resonance imaging (MRI) sequences with advanced parallel imaging have the potential to reduce scan time with equivalent image quality and accuracy compared with standard two-dimensional (2D) flow MRI. We compared 4D flow to standard 2D flow sequences using a constant and pulsatile flow phantom at 3 T. Methods Two accelerated 4D flow sequences (GRAPPA2 and k-t-GRAPPA5) were evaluated regarding the concordance of flow volumes, flow velocities, and reproducibility as well as dependency on measuring plane and velocity encoding (Venc). The calculated flow volumes and peak velocities of the phantom were used as reference standard. Flow analysis was performed using the custom-made software “Bloodline”. Results No significant differences in flow volume were found between the 2D, both 4D flow MRI sequences, and the pump reference (p = 0.994) or flow velocities (p = 0.998) in continuous and pulsatile flow. An excellent correlation (R = 0.99–1.0) with a reference standard and excellent reproducibility of measurements (R = 0.99) was achieved for all sequences. A Venc overestimated by up to two times had no impact on flow measurements. However, misaligned measuring planes led to an increasing underestimation of flow volume and mean velocity in 2D flow accuracy, while both 4D flow measurements were not affected. Scan time was significantly shorter for k-t-GRAPPA5 (1:54 ± 0:01 min, mean ± standard deviation) compared to GRAPPA2 (3:56 ± 0:02 min) (p = 0.002). Conclusions Both 4D flow sequences demonstrated equal agreement with 2D flow measurements, without impact of Venc overestimation and plane misalignment. The highly accelerated k-t-GRAPPA5 sequence yielded results similar to those of GRAPPA2.
Collapse
Affiliation(s)
- Sebastian Ebel
- Department of Diagnostic and Interventional Radiology, University of Leipzig - Heart Centre, Leipzig Strümpellstrasse 39, 04289, Leipzig, Germany.
| | - Lisa Hübner
- Department of Diagnostic and Interventional Radiology, University of Leipzig - Heart Centre, Leipzig Strümpellstrasse 39, 04289, Leipzig, Germany
| | - Benjamin Köhler
- Department of Simulations and Graphics, University of Magdeburg, Magdeburg, Germany
| | - Siegfried Kropf
- Institute for Biometrics and Medical Informatics, University of Magdeburg, Magdeburg, Germany
| | - Bernhard Preim
- Department of Simulations and Graphics, University of Magdeburg, Magdeburg, Germany
| | - Bernd Jung
- Department of Diagnostic, Interventional and Paediatric Radiology, University of Bern, Bern, Switzerland
| | - Matthias Grothoff
- Department of Diagnostic and Interventional Radiology, University of Leipzig - Heart Centre, Leipzig Strümpellstrasse 39, 04289, Leipzig, Germany
| | - Matthias Gutberlet
- Department of Diagnostic and Interventional Radiology, University of Leipzig - Heart Centre, Leipzig Strümpellstrasse 39, 04289, Leipzig, Germany
| |
Collapse
|
21
|
Liu J, Koskas L, Faraji F, Kao E, Wang Y, Haraldsson H, Kefayati S, Zhu C, Ahn S, Laub G, Saloner D. Highly accelerated intracranial 4D flow MRI: evaluation of healthy volunteers and patients with intracranial aneurysms. MAGMA (NEW YORK, N.Y.) 2018; 31:295-307. [PMID: 28785850 PMCID: PMC5803461 DOI: 10.1007/s10334-017-0646-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2017] [Revised: 07/27/2017] [Accepted: 07/28/2017] [Indexed: 02/01/2023]
Abstract
OBJECTIVES To evaluate an accelerated 4D flow MRI method that provides high temporal resolution in a clinically feasible acquisition time for intracranial velocity imaging. MATERIALS AND METHODS Accelerated 4D flow MRI was developed by using a pseudo-random variable-density Cartesian undersampling strategy (CIRCUS) with the combination of k-t, parallel imaging and compressed sensing image reconstruction techniques (k-t SPARSE-SENSE). Four-dimensional flow data were acquired on five healthy volunteers and eight patients with intracranial aneurysms using CIRCUS (acceleration factor of R = 4, termed CIRCUS4) and GRAPPA (R = 2, termed GRAPPA2) as the reference method. Images with three times higher temporal resolution (R = 12, CIRCUS12) were also reconstructed from the same acquisition as CIRCUS4. Qualitative and quantitative image assessment was performed on the images acquired with different methods, and complex flow patterns in the aneurysms were identified and compared. RESULTS Four-dimensional flow MRI with CIRCUS was achieved in 5 min and allowed further improved temporal resolution of <30 ms. Volunteer studies showed similar qualitative and quantitative evaluation obtained with the proposed approach compared to the reference (overall image scores: GRAPPA2 3.2 ± 0.6; CIRCUS4 3.1 ± 0.7; CIRCUS12 3.3 ± 0.4; difference of the peak velocities: -3.83 ± 7.72 cm/s between CIRCUS4 and GRAPPA2, -1.72 ± 8.41 cm/s between CIRCUS12 and GRAPPA2). In patients with intracranial aneurysms, the higher temporal resolution improved capturing of the flow features in intracranial aneurysms (pathline visualization scores: GRAPPA2 2.2 ± 0.2; CIRCUS4 2.5 ± 0.5; CIRCUS12 2.7 ± 0.6). CONCLUSION The proposed rapid 4D flow MRI with a high temporal resolution is a promising tool for evaluating intracranial aneurysms in a clinically feasible acquisition time.
Collapse
Affiliation(s)
- Jing Liu
- Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry St, Suite 350, San Francisco, CA, 94107, USA.
| | - Louise Koskas
- Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry St, Suite 350, San Francisco, CA, 94107, USA
| | - Farshid Faraji
- Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry St, Suite 350, San Francisco, CA, 94107, USA
| | - Evan Kao
- Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry St, Suite 350, San Francisco, CA, 94107, USA
| | - Yan Wang
- Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry St, Suite 350, San Francisco, CA, 94107, USA
| | - Henrik Haraldsson
- Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry St, Suite 350, San Francisco, CA, 94107, USA
| | - Sarah Kefayati
- Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry St, Suite 350, San Francisco, CA, 94107, USA
| | - Chengcheng Zhu
- Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry St, Suite 350, San Francisco, CA, 94107, USA
| | | | | | - David Saloner
- Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry St, Suite 350, San Francisco, CA, 94107, USA
- Radiology Service, VA Medical Center, San Francisco, CA, USA
| |
Collapse
|
22
|
Pagé G, Bettoni J, Salsac AV, Balédent O. Influence of principal component analysis acceleration factor on velocity measurement in 2D and 4D PC-MRI. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2018; 31:469-481. [PMID: 29357015 DOI: 10.1007/s10334-018-0673-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2017] [Revised: 12/28/2017] [Accepted: 01/03/2018] [Indexed: 11/24/2022]
Abstract
OBJECTIVE The objective of the study was to determine how to optimize 2D and 4D phase-contrast magnetic resonance imaging (PC-MRI) acquisitions to acquire flow velocities in millimetric vessels. In particular, we search for the best compromise between acquisition time and accuracy and assess the influence of the principal component analysis (PCA). MATERIALS AND METHODS 2D and 4D PC-MRI measurements are conducted within two in vitro vessel phantoms: a Y-bifurcation phantom, the branches of which range from 2 to 5 mm in diameter, and a physiological subject-specific phantom of the carotid bifurcation. The same sequences are applied in vivo in carotid vasculature. RESULTS For a vessel oriented in the axial direction, both 2D and axial 4D PC-MRI provided accuracy measurements regardless of the k-t PCA factor, while the acquisition time is reduced by a factor 6 for k-t PCA maximum value. The in vivo measurements show that the proposed sequences are adequate to acquire 2D and 4D velocity fields in millimetric vessels and with clinically realistic time durations. CONCLUSION The study shows the feasibility of conducting fast, high-resolution PC-MRI flow measurements in millimetric vessels and that it is worth maximizing the k-t PCA factor to reduce the acquisition time in the case of 2D and 4D axial acquisitions.
Collapse
Affiliation(s)
- Gwenaël Pagé
- BioFlow Image, University Hospital of Amiens Picardy, Université de Picardie Jules Verne, Avenue Rene Laennec, Salouël, 80480, Amiens, France.
| | - Jérémie Bettoni
- Maxillo-Facial Surgery, University Hospital of Amiens-Picardie, Amiens, France
| | - Anne-Virginie Salsac
- Biomechanics and Bioengineering Laboratory (UMR CNRS 7338), Sorbonne Universités, Université de Technologie de Compiègne-CNRS, Compiègne, France
| | - Olivier Balédent
- BioFlow Image, University Hospital of Amiens Picardy, Université de Picardie Jules Verne, Avenue Rene Laennec, Salouël, 80480, Amiens, France.,Laboratory of Image Processing, University Hospital of Amiens-Picardie, Amiens, France
| |
Collapse
|
23
|
Bastkowski R, Weiss K, Maintz D, Giese D. Self-gated golden-angle spiral 4D flow MRI. Magn Reson Med 2018; 80:904-913. [PMID: 29344990 DOI: 10.1002/mrm.27085] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Revised: 12/07/2017] [Accepted: 12/20/2017] [Indexed: 12/31/2022]
Affiliation(s)
- Rene Bastkowski
- Department of Radiology, University Hospital of Cologne, Cologne, Germany
| | - Kilian Weiss
- Department of Radiology, University Hospital of Cologne, Cologne, Germany
- Philips Healthcare Germany, Hamburg, Germany
| | - David Maintz
- Department of Radiology, University Hospital of Cologne, Cologne, Germany
| | - Daniel Giese
- Department of Radiology, University Hospital of Cologne, Cologne, Germany
| |
Collapse
|
24
|
Bettoni J, Pagé G, Salsac AV, Constans JM, Testelin S, Devauchelle B, Balédent O, Dakpé S. 3T non-injected phase-contrast MRI sequences for the mapping of the external carotid branches: In vivo radio-anatomical pilot study for feasibility analysis. J Craniomaxillofac Surg 2018; 46:98-106. [DOI: 10.1016/j.jcms.2017.09.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2017] [Revised: 07/19/2017] [Accepted: 09/11/2017] [Indexed: 10/18/2022] Open
|
25
|
Bollache E, Barker AJ, Dolan RS, Carr JC, van Ooij P, Ahmadian R, Powell A, Collins JD, Geiger J, Markl M. k-t accelerated aortic 4D flow MRI in under two minutes: Feasibility and impact of resolution, k-space sampling patterns, and respiratory navigator gating on hemodynamic measurements. Magn Reson Med 2017; 79:195-207. [PMID: 28266062 DOI: 10.1002/mrm.26661] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2016] [Revised: 02/08/2017] [Accepted: 02/08/2017] [Indexed: 01/29/2023]
Abstract
PURPOSE To assess the performance of highly accelerated free-breathing aortic four-dimensional (4D) flow MRI acquired in under 2 minutes compared to conventional respiratory gated 4D flow. METHODS Eight k-t accelerated nongated 4D flow MRI (parallel MRI with extended and averaged generalized autocalibrating partially parallel acquisition kernels [PEAK GRAPPA], R = 5, TRes = 67.2 ms) using four ky -kz Cartesian sampling patterns (linear, center-out, out-center-out, random) and two spatial resolutions (SRes1 = 3.5 × 2.3 × 2.6 mm3 , SRes2 = 4.5 × 2.3 × 2.6 mm3 ) were compared in vitro (aortic coarctation flow phantom) and in 10 healthy volunteers, to conventional 4D flow (16 mm-navigator acceptance window; R = 2; TRes = 39.2 ms; SRes = 3.2 × 2.3 × 2.4 mm3 ). The best k-t accelerated approach was further assessed in 10 patients with aortic disease. RESULTS The k-t accelerated in vitro aortic peak flow (Qmax), net flow (Qnet), and peak velocity (Vmax) were lower than conventional 4D flow indices by ≤4.7%, ≤ 11%, and ≤22%, respectively. In vivo k-t accelerated acquisitions were significantly shorter but showed a trend to lower image quality compared to conventional 4D flow. Hemodynamic indices for linear and out-center-out k-space samplings were in agreement with conventional 4D flow (Qmax ≤ 13%, Qnet ≤ 13%, Vmax ≤ 17%, P > 0.05). CONCLUSION Aortic 4D flow MRI in under 2 minutes is feasible with moderate underestimation of flow indices. Differences in k-space sampling patterns suggest an opportunity to mitigate image artifacts by an optimal trade-off between scan time, acceleration, and k-space sampling. Magn Reson Med 79:195-207, 2018. © 2018 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Emilie Bollache
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Alex J Barker
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Ryan Scott Dolan
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - James C Carr
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Pim van Ooij
- Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands
| | - Rouzbeh Ahmadian
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Alex Powell
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Jeremy D Collins
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Julia Geiger
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Würzburg, Germany
| | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Chicago, Illinois, USA
| |
Collapse
|
26
|
Schnell S, Ansari SA, Wu C, Garcia J, Murphy IG, Rahman OA, Rahsepar AA, Aristova M, Collins JD, Carr JC, Markl M. Accelerated dual-venc 4D flow MRI for neurovascular applications. J Magn Reson Imaging 2017; 46:102-114. [PMID: 28152256 DOI: 10.1002/jmri.25595] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2016] [Accepted: 11/28/2016] [Indexed: 12/28/2022] Open
Abstract
PURPOSE To improve velocity-to-noise ratio (VNR) and dynamic velocity range of 4D flow magnetic resonance imaging (MRI) by using dual-velocity encoding (dual-venc) with k-t generalized autocalibrating partially parallel acquisition (GRAPPA) acceleration. MATERIALS AND METHODS A dual-venc 4D flow MRI sequence with k-t GRAPPA acceleration was developed using a shared reference scan followed by three-directional low- and high-venc scans (repetition time / echo time / flip angle = 6.1 msec / 3.4 msec / 15°, temporal/spatial resolution = 43.0 msec/1.2 × 1.2 × 1.2 mm3 ). The high-venc data were used to correct for aliasing in the low-venc data, resulting in a single dataset with the favorable VNR of the low-venc but without velocity aliasing. The sequence was validated with a 3T MRI scanner in phantom experiments and applied in 16 volunteers to investigate its feasibility for assessing intracranial hemodynamics (net flow and peak velocity) at the major intracranial vessels. In addition, image quality and image noise were assessed in the in vivo acquisitions. RESULTS All 4D flow MRI scans were acquired successfully with an acquisition time of 20 ± 4 minutes. The shared reference scan reduced the total acquisition time by 12.5% compared to two separate scans. Phantom experiments showed 51.4% reduced noise for dual-venc compared to high-venc and an excellent agreement of velocities (ρ = 0.8, P < 0.001). The volunteer data showed decreased noise in dual-venc data (54.6% lower) compared to high-venc, and improved image quality, as graded by two observers: fewer artifacts (P < 0.0001), improved vessel conspicuity (P < 0.0001), and reduced noise (P < 0.0001). CONCLUSION Dual-venc 4D flow MRI exhibits the superior VNR of the low-venc acquisition and reliably incorporates low- and high-velocity fields simultaneously. In vitro and in vivo data demonstrate improved flow visualization, image quality, and image noise. LEVEL OF EVIDENCE 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:102-114.
Collapse
Affiliation(s)
- Susanne Schnell
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Sameer A Ansari
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Neurosurgery, Northwestern University, Chicago, Illinois, USA
| | - Can Wu
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Chicago, Illinois, USA
| | - Julio Garcia
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Cardiac Sciences - Stephenson Cardiac Imaging Centre, Cumming School of Medicine, University of Calgary, Calgary, Canada
| | - Ian G Murphy
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Ozair A Rahman
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Amir A Rahsepar
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Maria Aristova
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Jeremy D Collins
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - James C Carr
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Neurosurgery, Northwestern University, Chicago, Illinois, USA
| |
Collapse
|
27
|
Qualitative grading of aortic regurgitation: a pilot study comparing CMR 4D flow and echocardiography. Int J Cardiovasc Imaging 2016; 32:301-307. [PMID: 26498478 PMCID: PMC4737795 DOI: 10.1007/s10554-015-0779-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2015] [Accepted: 09/25/2015] [Indexed: 11/21/2022]
Abstract
Over the past 10 years there has been intense research in the development of volumetric visualization of intracardiac flow by cardiac magnetic resonance (CMR). This volumetric time resolved technique called CMR 4D flow imaging has several advantages over standard CMR. It offers anatomical, functional and flow information in a single free-breathing, ten-minute acquisition. However, the data obtained is large and its processing requires dedicated software. We evaluated a cloud-based application package that combines volumetric data correction and visualization of CMR 4D flow data, and assessed its accuracy for the detection and grading of aortic valve regurgitation using transthoracic echocardiography as reference. Between June 2014 and January 2015, patients planned for clinical CMR were consecutively approached to undergo the supplementary CMR 4D flow acquisition. Fifty four patients (median age 39 years, 32 males) were included. Detection and grading of the aortic valve regurgitation using CMR 4D flow imaging were evaluated against transthoracic echocardiography. The agreement between 4D flow CMR and transthoracic echocardiography for grading of aortic valve regurgitation was good (κ = 0.73). To identify relevant, more than mild aortic valve regurgitation, CMR 4D flow imaging had a sensitivity of 100 % and specificity of 98 %. Aortic regurgitation can be well visualized, in a similar manner as transthoracic echocardiography, when using CMR 4D flow imaging.
Collapse
|
28
|
Mura J, Pino AM, Sotelo J, Valverde I, Tejos C, Andia ME, Irarrazaval P, Uribe S. Enhancing the Velocity Data From 4D Flow MR Images by Reducing its Divergence. IEEE TRANSACTIONS ON MEDICAL IMAGING 2016; 35:2353-2364. [PMID: 27214892 DOI: 10.1109/tmi.2016.2570010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Velocity measurements from 4D flow MRI are prone to be affected by several imperfections of the MR system. Assuming that blood is incompressible, we propose a novel method for enhancing the velocity field by reducing its divergence. To enhance the velocity data, we added a corrector velocity to each voxel such that the divergence is minimized. The method was validated using an analytical Womersley flow model for different settings of resolution and noise levels. The performance of the proposed method was also assessed in volunteers and patients. Results demonstrated a significant reduction of the divergence depending on the size of the regularization term, obtaining a reduction close to 50% of the mean divergence with negligible modification of flow parameters. Remarkably, we found that the reduction of the divergence, in percentage, was independent of volunteers, resolution or noise.
Collapse
|
29
|
Chelu RG, Wanambiro KW, Hsiao A, Swart LE, Voogd T, van den Hoven AT, van Kranenburg M, Coenen A, Boccalini S, Wielopolski PA, Vogel MW, Krestin GP, Vasanawala SS, Budde RP, Roos-Hesselink JW, Nieman K. Cloud-processed 4D CMR flow imaging for pulmonary flow quantification. Eur J Radiol 2016; 85:1849-1856. [DOI: 10.1016/j.ejrad.2016.07.018] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2016] [Revised: 06/07/2016] [Accepted: 07/24/2016] [Indexed: 11/28/2022]
|
30
|
Schnell S, Wu C, Ansari SA. Four-dimensional MRI flow examinations in cerebral and extracerebral vessels - ready for clinical routine? Curr Opin Neurol 2016; 29:419-28. [PMID: 27262148 PMCID: PMC4939804 DOI: 10.1097/wco.0000000000000341] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
PURPOSE OF REVIEW To evaluate the feasibility of 4-dimensional (4D) flow MRI for the clinical assessment of cerebral and extracerebral vascular hemodynamics in patients with neurovascular disease. RECENT FINDINGS 4D flow MRI has been applied in multiple studies to qualitatively and quantitatively study intracranial aneurysm blood flow for potential risk stratification and to assess treatment efficacy of various neurovascular lesions, including intraaneurysmal and parent artery blood flow after flow diverter stent placement and staged embolizations of arteriovenous malformations and vein of Galen aneurysmal malformations. Recently, the technique has been utilized to characterize age-related changes of normal cerebral hemodynamics in healthy individuals over a broad age range. SUMMARY 4D flow MRI is a useful tool for the noninvasive, volumetric and quantitative hemodynamic assessment of neurovascular disease without the need for gadolinium contrast agents. Further improvements are warranted to overcome technical limitations before broader clinical implementation. Current developments, such as advanced acceleration techniques (parallel imaging and compressed sensing) for faster data acquisition, dual or multiple velocity encoding strategies for more accurate arterial and venous flow quantification, ultrahigh-field strengths to achieve higher spatial resolution and streamlined postprocessing workflow for more efficient and standardized flow analysis, are promising advancements in 4D flow MRI.
Collapse
Affiliation(s)
- Susanne Schnell
- Dept. of Radiology, Northwestern University, Feinberg School of Medicine, Chicago, Illinois
| | - Can Wu
- Dept. of Radiology, Northwestern University, Feinberg School of Medicine, Chicago, Illinois
- Dept. of Biomedical Engineering, Northwestern University, Evanston, Illinois
| | - Sameer A. Ansari
- Dept. of Radiology, Northwestern University, Feinberg School of Medicine, Chicago, Illinois
- Dept. of Neurology, Northwestern University, Feinberg School of Medicine, Chicago, Illinois
- Dept. of Neurological Surgery, Northwestern University, Feinberg School of Medicine, Chicago, Illinois
| |
Collapse
|
31
|
Sun A, Zhao B, Ma K, Zhou Z, He L, Li R, Yuan C. Accelerated phase contrast flow imaging with direct complex difference reconstruction. Magn Reson Med 2016; 77:1036-1048. [PMID: 27016025 DOI: 10.1002/mrm.26184] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2015] [Revised: 01/31/2016] [Accepted: 02/05/2016] [Indexed: 11/09/2022]
Abstract
PURPOSE To propose and evaluate a new model-based reconstruction method for highly accelerated phase-contrast magnetic resonance imaging (PC-MRI) with sparse sampling. THEORY AND METHODS This work presents a new constrained reconstruction method based on low-rank and sparsity constraints to accelerate PC-MRI. More specifically, we formulate the image reconstruction problem into separate reconstructions of flow-reference image sequence and complex differences. We then utilize the joint partial separability and sparsity constraints to enable high quality reconstruction from highly undersampled (k,t)-space data. We further integrate the proposed method with ESPIRiT based parallel imaging model to effectively handle multichannel acquisition. RESULTS The proposed method was evaluated with in vivo data acquired from both 2D and 3D PC flow imaging experiments, and compared with several state-of-the-art methods. Experimental results demonstrate that the proposed method leads to more accurate velocity reconstruction from highly undersampled (k,t)-space data, and particularly superior capability of capturing the peak velocity of blood flow. In terms of flow visualization, blood flow patterns obtained from the proposed reconstruction also exhibit better agreement with those obtained from the fully sampled reference. CONCLUSION The proposed method achieves improved accuracy over several state-of-the-art methods for velocity reconstruction with highly accelerated (k,t)-space data. Magn Reson Med 77:1036-1048, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Aiqi Sun
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Bo Zhao
- Department of Electrical and Computer Engineering and Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Ke Ma
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Zechen Zhou
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Le He
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Rui Li
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Chun Yuan
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.,Vascular Imaging Lab, Department of Radiology, University of Washington, Seattle, Washington, USA
| |
Collapse
|
32
|
Advanced flow MRI: emerging techniques and applications. Clin Radiol 2016; 71:779-95. [PMID: 26944696 DOI: 10.1016/j.crad.2016.01.011] [Citation(s) in RCA: 85] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2015] [Revised: 12/10/2015] [Accepted: 01/10/2016] [Indexed: 12/12/2022]
Abstract
Magnetic resonance imaging (MRI) techniques provide non-invasive and non-ionising methods for the highly accurate anatomical depiction of the heart and vessels throughout the cardiac cycle. In addition, the intrinsic sensitivity of MRI to motion offers the unique ability to acquire spatially registered blood flow simultaneously with the morphological data, within a single measurement. In clinical routine, flow MRI is typically accomplished using methods that resolve two spatial dimensions in individual planes and encode the time-resolved velocity in one principal direction, typically oriented perpendicular to the two-dimensional (2D) section. This review describes recently developed advanced MRI flow techniques, which allow for more comprehensive evaluation of blood flow characteristics, such as real-time flow imaging, 2D multiple-venc phase contrast MRI, four-dimensional (4D) flow MRI, quantification of complex haemodynamic properties, and highly accelerated flow imaging. Emerging techniques and novel applications are explored. In addition, applications of these new techniques for the improved evaluation of cardiovascular (aorta, pulmonary arteries, congenital heart disease, atrial fibrillation, coronary arteries) as well as cerebrovascular disease (intra-cranial arteries and veins) are presented.
Collapse
|
33
|
Stankovic Z. Four-dimensional flow magnetic resonance imaging in cirrhosis. World J Gastroenterol 2016; 22:89-102. [PMID: 26755862 PMCID: PMC4698511 DOI: 10.3748/wjg.v22.i1.89] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2015] [Revised: 08/08/2015] [Accepted: 10/13/2015] [Indexed: 02/06/2023] Open
Abstract
Since its introduction in the 1970’s, magnetic resonance imaging (MRI) has become a standard imaging modality. With its broad and standardized application, it is firmly established in the clinical routine and an essential element in cardiovascular and abdominal imaging. In addition to sonography and computer tomography, MRI is a valuable tool for diagnosing cardiovascular and abdominal diseases, for determining disease severity, and for assessing therapeutic success. MRI techniques have improved over the last few decades, revealing not just morphologic information, but functional information about perfusion, diffusion and hemodynamics as well. Four-dimensional (4D) flow MRI, a time-resolved phase contrast-MRI with three-dimensional (3D) anatomic coverage and velocity encoding along all three flow directions has been used to comprehensively assess complex cardiovascular hemodynamics in multiple regions of the body. The technique enables visualization of 3D blood flow patterns and retrospective quantification of blood flow parameters in a region of interest. Over the last few years, 4D flow MRI has been increasingly performed in the abdominal region. By applying different acceleration techniques, taking 4D flow MRI measurements has dropped to a reasonable scanning time of 8 to 12 min. These new developments have encouraged a growing number of patient studies in the literature validating the technique’s potential for enhanced evaluation of blood flow parameters within the liver’s complex vascular system. The purpose of this review article is to broaden our understanding of 4D flow MRI for the assessment of liver hemodynamics by providing insights into acquisition, data analysis, visualization and quantification. Furthermore, in this article we highlight its development, focussing on the clinical application of the technique.
Collapse
|
34
|
Vasanawala SS, Hanneman K, Alley MT, Hsiao A. Congenital heart disease assessment with 4D flow MRI. J Magn Reson Imaging 2015; 42:870-86. [PMID: 25708923 DOI: 10.1002/jmri.24856] [Citation(s) in RCA: 87] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2014] [Accepted: 12/18/2014] [Indexed: 11/10/2022] Open
Abstract
With improvements in surgical and medical management, patients with congenital heart disease (CHD) are often living well into adulthood. MRI provides critical data for diagnosis and monitoring of these patients, yielding information on cardiac anatomy, blood flow, and cardiac function. Though historically these exams have been complex and lengthy, four-dimensional (4D) flow is emerging as a single fast technique for comprehensive assessment of CHD. The 4D flow consists of a volumetric time-resolved acquisition that is gated to the cardiac cycle, providing a time-varying vector field of blood flow as well as registered anatomic images. In this article, we provide an overview of MRI evaluation of congenital heart disease by means of example of three relatively common representative conditions: tetralogy of Fallot, aortic coarctation, and anomalous pulmonary venous drainage. Then 4D flow data acquisition, data correction, and postprocessing techniques are reviewed. We conclude with several examples that highlight the comprehensive nature of the evaluation of congenital heart disease with 4D flow.
Collapse
Affiliation(s)
| | - Kate Hanneman
- Department of Radiology, University of California, San Diego, San Diego, California, USA
| | - Marcus T Alley
- Department of Radiology, Stanford University, Stanford, California, USA
| | | |
Collapse
|
35
|
K-t GRAPPA-accelerated 4D flow MRI of liver hemodynamics: influence of different acceleration factors on qualitative and quantitative assessment of blood flow. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2014; 28:149-59. [PMID: 25099493 DOI: 10.1007/s10334-014-0456-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2014] [Revised: 07/08/2014] [Accepted: 07/18/2014] [Indexed: 12/18/2022]
Abstract
OBJECTIVE We sought to evaluate the feasibility of k-t parallel imaging for accelerated 4D flow MRI in the hepatic vascular system by investigating the impact of different acceleration factors. MATERIALS AND METHODS k-t GRAPPA accelerated 4D flow MRI of the liver vasculature was evaluated in 16 healthy volunteers at 3T with acceleration factors R = 3, R = 5, and R = 8 (2.0 × 2.5 × 2.4 mm(3), TR = 82 ms), and R = 5 (TR = 41 ms); GRAPPA R = 2 was used as the reference standard. Qualitative flow analysis included grading of 3D streamlines and time-resolved particle traces. Quantitative evaluation assessed velocities, net flow, and wall shear stress (WSS). RESULTS Significant scan time savings were realized for all acceleration factors compared to standard GRAPPA R = 2 (21-71 %) (p < 0.001). Quantification of velocities and net flow offered similar results between k-t GRAPPA R = 3 and R = 5 compared to standard GRAPPA R = 2. Significantly increased leakage artifacts and noise were seen between standard GRAPPA R = 2 and k-t GRAPPA R = 8 (p < 0.001) with significant underestimation of peak velocities and WSS of up to 31 % in the hepatic arterial system (p <0.05). WSS was significantly underestimated up to 13 % in all vessels of the portal venous system for k-t GRAPPA R = 5, while significantly higher values were observed for the same acceleration with higher temporal resolution in two veins (p < 0.05). CONCLUSION k-t acceleration of 4D flow MRI is feasible for liver hemodynamic assessment with acceleration factors R = 3 and R = 5 resulting in a scan time reduction of at least 40 % with similar quantitation of liver hemodynamics compared with GRAPPA R = 2.
Collapse
|
36
|
Stankovic Z, Allen BD, Garcia J, Jarvis KB, Markl M. 4D flow imaging with MRI. Cardiovasc Diagn Ther 2014; 4:173-92. [PMID: 24834414 DOI: 10.3978/j.issn.2223-3652.2014.01.02] [Citation(s) in RCA: 102] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2013] [Accepted: 10/21/2013] [Indexed: 12/22/2022]
Abstract
Magnetic resonance imaging (MRI) has become an important tool for the clinical evaluation of patients with cardiovascular disease. Since its introduction in the late 1980s, 2-dimensional phase contrast MRI (2D PC-MRI) has become a routine part of standard-of-care cardiac MRI for the assessment of regional blood flow in the heart and great vessels. More recently, time-resolved PC-MRI with velocity encoding along all three flow directions and three-dimensional (3D) anatomic coverage (also termed '4D flow MRI') has been developed and applied for the evaluation of cardiovascular hemodynamics in multiple regions of the human body. 4D flow MRI allows for the comprehensive evaluation of complex blood flow patterns by 3D blood flow visualization and flexible retrospective quantification of flow parameters. Recent technical developments, including the utilization of advanced parallel imaging techniques such as k-t GRAPPA, have resulted in reasonable overall scan times, e.g., 8-12 minutes for 4D flow MRI of the aorta and 10-20 minutes for whole heart coverage. As a result, the application of 4D flow MRI in a clinical setting has become more feasible, as documented by an increased number of recent reports on the utility of the technique for the assessment of cardiac and vascular hemodynamics in patient studies. A number of studies have demonstrated the potential of 4D flow MRI to provide an improved assessment of hemodynamics which might aid in the diagnosis and therapeutic management of cardiovascular diseases. The purpose of this review is to describe the methods used for 4D flow MRI acquisition, post-processing and data analysis. In addition, the article provides an overview of the clinical applications of 4D flow MRI and includes a review of applications in the heart, thoracic aorta and hepatic system.
Collapse
Affiliation(s)
- Zoran Stankovic
- 1 Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, USA ; 2 Department Biomedical Engineering, McCormick School of Engineering, Northwestern University, Chicago, USA
| | - Bradley D Allen
- 1 Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, USA ; 2 Department Biomedical Engineering, McCormick School of Engineering, Northwestern University, Chicago, USA
| | - Julio Garcia
- 1 Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, USA ; 2 Department Biomedical Engineering, McCormick School of Engineering, Northwestern University, Chicago, USA
| | - Kelly B Jarvis
- 1 Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, USA ; 2 Department Biomedical Engineering, McCormick School of Engineering, Northwestern University, Chicago, USA
| | - Michael Markl
- 1 Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, USA ; 2 Department Biomedical Engineering, McCormick School of Engineering, Northwestern University, Chicago, USA
| |
Collapse
|
37
|
Santelli C, Schaeffter T, Kozerke S. Radial k-t SPIRiT: autocalibrated parallel imaging for generalized phase-contrast MRI. Magn Reson Med 2013; 72:1233-45. [PMID: 24258701 DOI: 10.1002/mrm.25030] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2013] [Revised: 09/20/2013] [Accepted: 10/12/2013] [Indexed: 11/06/2022]
Abstract
PURPOSE To extend SPIRiT to additionally exploit temporal correlations for highly accelerated generalized phase-contrast MRI and to compare the performance of the proposed radial k-t SPIRiT method relative to frame-by-frame SPIRiT and radial k-t GRAPPA reconstruction for velocity and turbulence mapping in the aortic arch. THEORY AND METHODS Free-breathing navigator-gated two-dimensional radial cine imaging with three-directional multi-point velocity encoding was implemented and fully sampled data were obtained in the aortic arch of healthy volunteers. Velocities were encoded with three different first gradient moments per axis to permit quantification of mean velocity and turbulent kinetic energy. Velocity and turbulent kinetic energy maps from up to 14-fold undersampled data were compared for k-t SPIRiT, frame-by-frame SPIRiT, and k-t GRAPPA relative to the fully sampled reference. RESULTS Using k-t SPIRiT, improvements in magnitude and velocity reconstruction accuracy were found. Temporally resolved magnitude profiles revealed a reduction in spatial blurring with k-t SPIRiT compared with frame-by-frame SPIRiT and k-t GRAPPA for all velocity encodings, leading to improved estimates of turbulent kinetic energy. CONCLUSION k-t SPIRiT offers improved reconstruction accuracy at high radial undersampling factors and hence facilitates the use of generalized phase-contrast MRI for routine use.
Collapse
Affiliation(s)
- Claudio Santelli
- Imaging Sciences and Biomedical Engineering, King's College, London, United Kingdom; Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | | | | |
Collapse
|
38
|
Stankovic Z, Jung B, Collins J, Russe MF, Carr J, Euringer W, Stehlin L, Csatari Z, Strohm PC, Langer M, Markl M. Reproducibility study of four-dimensional flow MRI of arterial and portal venous liver hemodynamics: influence of spatio-temporal resolution. Magn Reson Med 2013; 72:477-84. [PMID: 24018798 DOI: 10.1002/mrm.24939] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2013] [Revised: 08/01/2013] [Accepted: 08/08/2013] [Indexed: 12/22/2022]
Abstract
PURPOSE To evaluate influence of variation in spatio-temporal resolution and scan-rescan reproducibility on three-dimensional (3D) visualization and quantification of arterial and portal venous (PV) liver hemodynamics at four-dimensional (4D) flow MRI. METHODS Scan-rescan reproducibility of 3D hemodynamic analysis of the liver was evaluated in 10 healthy volunteers using 4D flow MRI at 3T with three different spatio-temporal resolutions (2.4 × 2.0 × 2.4 mm(3), 61.2 ms; 2.5 × 2.0 × 2.4 mm(3), 81.6 ms; 2.6 × 2.5 × 2.6 mm(3), 80 ms) and thus different total scan times. Qualitative flow analysis used 3D streamlines and time-resolved particle traces. Quantitative evaluation was based on maximum and mean velocities, flow volume, and vessel lumen area in the hepatic arterial and PV systems. RESULTS 4D flow MRI showed good interobserver variability for assessment of arterial and PV liver hemodynamics. 3D flow visualization revealed limitations for the left intrahepatic PV branch. Lower spatio-temporal resolution resulted in underestimation of arterial velocities (mean 15%, P < 0.05). For the PV system, hemodynamic analyses showed significant differences in the velocities for intrahepatic portal vein vessels (P < 0.05). Scan-rescan reproducibility was good except for flow volumes in the arterial system. CONCLUSION 4D flow MRI for assessment of liver hemodynamics can be performed with low interobserver variability and good reproducibility. Higher spatio-temporal resolution is necessary for complete assessment of the hepatic blood flow required for clinical applications.
Collapse
Affiliation(s)
- Zoran Stankovic
- Department of Radiology, Northwestern University, Chicago, Illinois, USA; Department of Biomedical Engineering, Northwestern University, Chicago, Illinois, USA; Department of Diagnostic Radiology and Medical Physics, University Medical Center Freiburg, Freiburg, Germany
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
39
|
Schnell S, Markl M, Entezari P, Mahadewia RJ, Semaan E, Stankovic Z, Collins J, Carr J, Jung B. k-t GRAPPA accelerated four-dimensional flow MRI in the aorta: effect on scan time, image quality, and quantification of flow and wall shear stress. Magn Reson Med 2013; 72:522-33. [PMID: 24006309 DOI: 10.1002/mrm.24925] [Citation(s) in RCA: 70] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2013] [Revised: 06/27/2013] [Accepted: 07/28/2013] [Indexed: 01/29/2023]
Abstract
PURPOSE The purpose of this study was to evaluate the utility of k-t parallel imaging for accelerating aortic four-dimensional (4D)-flow MRI. The aim was to systematically investigate the impact of different acceleration factors and number of coil elements on acquisition time, image quality and quantification of hemodynamic parameters. METHODS k-t accelerated 4D-flow MRI (spatial/temporal resolution = 2.1 × 2.5 × 2.5 mm/40.0 ms) was acquired in 10 healthy volunteers with acceleration factors R = 3, 5, and 8 using 12- and 32-channel receiver coils. Results were compared with conventional parallel imaging (GRAPPA [generalized autocalibrating partial parallel acquisition], R = 2). Data analysis included radiological grading of three-dimensional blood flow visualization quality as well as quantification of blood flow, velocities and wall shear stress (WSS). RESULTS k-t GRAPPA significantly reduced scan time by 28%, 54%, and 68%, for R = 3, 5, and 8, respectively, while maintaining image quality as demonstrated by overall similar image quality grading. Significant differences in peak WSS (diff12ch = -5.9%, diff32ch = 18.5%) and mean WSS (diff32ch = 13.9%) were found at the descending aorta for both receiver coils for R = 5 (PWSS < 0.04). Peak velocity differed for R=8 at the aortic root (-7.4%) and descending aorta (-12%) with PpeakVelo < 0.03. CONCLUSION k-t GRAPPA acceleration with a 12- or 32-channel receiver coil and an acceleration of 3 or 5 can compete with a standard GRAPPA R = 2 acceleration.
Collapse
Affiliation(s)
- Susanne Schnell
- Department of Radiology, Northwestern University, Chicago, Illinois, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
40
|
Tresoldi D, Cadioli M, Ponzini R, Esposito A, De Cobelli F, Morbiducci U, Rizzo G. Mapping aortic hemodynamics using 3D cine phase contrast magnetic resonance parallel imaging: Evaluation of an anisotropic diffusion filter. Magn Reson Med 2013; 71:1621-31. [DOI: 10.1002/mrm.24811] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2013] [Revised: 04/24/2013] [Accepted: 04/25/2013] [Indexed: 11/08/2022]
Affiliation(s)
- D. Tresoldi
- Institute of Molecular Bioimaging and Physiology, CNR; Segrate (Milan) Italy
- Bioengineering Department; Politecnico di Milano; Milan Italy
| | | | | | - A. Esposito
- Department of Radiology; Scientific Institute H. S. Raffaele; Milan Italy
| | - F. De Cobelli
- Department of Radiology; Scientific Institute H. S. Raffaele; Milan Italy
| | - U. Morbiducci
- Department of Mechanical and Aerospace Engineering; Politecnico di Torino; Turin Italy
| | - G. Rizzo
- Institute of Molecular Bioimaging and Physiology, CNR; Segrate (Milan) Italy
| |
Collapse
|
41
|
Fast semi-automated analysis of pulse wave velocity in the thoracic aorta using high temporal resolution 4D flow MRI. J Cardiovasc Magn Reson 2013. [PMCID: PMC3560050 DOI: 10.1186/1532-429x-15-s1-p87] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
42
|
|