Li Z, Fu Z, Keerthivasan M, Bilgin A, Johnson K, Galons JP, Vedantham S, Martin DR, Altbach MI. Rapid high-resolution volumetric T 1 mapping using a highly accelerated stack-of-stars Look Locker technique. Magn Reson Imaging 2021; 79:28-37. [PMID: 33722634 PMCID: PMC8107135 DOI: 10.1016/j.mri.2021.03.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 03/03/2021] [Accepted: 03/03/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE To develop a fast volumetric T1 mapping technique. MATERIALS AND METHODS A stack-of-stars (SOS) Look Locker technique based on the acquisition of undersampled radial data (>30× relative to Nyquist) and an efficient multi-slab excitation scheme is presented. A principal-component based reconstruction is used to reconstruct T1 maps. Computer simulations were performed to determine the best choice of partitions per slab and degree of undersampling. The technique was validated in phantoms against reference T1 values measured with a 2D Cartesian inversion-recovery spin-echo technique. The SOS Look Locker technique was tested in brain (n = 4) and prostate (n = 5). Brain T1 mapping was carried out with and without kz acceleration and results between the two approaches were compared. Prostate T1 mapping was compared to standard techniques. A reproducibility study was conducted in brain and prostate. Statistical analyses were performed using linear regression and Bland Altman analysis. RESULTS Phantom T1 values showed excellent correlations between SOS Look Locker and the inversion-recovery spin-echo reference (r2 = 0.9965; p < 0.0001) and between SOS Look Locker with slab-selective and non-slab selective inversion pulses (r2 = 0.9999; p < 0.0001). In vivo results showed that full brain T1 mapping (1 mm3) with kz acceleration is achieved in 4 min 21 s. Full prostate T1 mapping (0.9 × 0.9 × 4 mm3) is achieved in 2 min 43 s. T1 values for brain and prostate were in agreement with literature values. A reproducibility study showed coefficients of variation in the range of 0.18-0.2% (brain) and 0.15-0.18% (prostate). CONCLUSION A rapid volumetric T1 mapping technique was developed. The technique enables high-resolution T1 mapping with adequate anatomical coverage in a clinically acceptable time.
Collapse
Affiliation(s)
- Zhitao Li
- Department of Electrical and Computer Engineering, the University of Arizona, Tucson, AZ 85721, USA; Department of Medical Imaging, the University of Arizona, Tucson, AZ 85724, USA
| | - Zhiyang Fu
- Department of Electrical and Computer Engineering, the University of Arizona, Tucson, AZ 85721, USA; Department of Medical Imaging, the University of Arizona, Tucson, AZ 85724, USA
| | - Mahesh Keerthivasan
- Department of Medical Imaging, the University of Arizona, Tucson, AZ 85724, USA; Siemens Healthcare USA, Tucson, AZ 85724, USA
| | - Ali Bilgin
- Department of Electrical and Computer Engineering, the University of Arizona, Tucson, AZ 85721, USA; Department of Medical Imaging, the University of Arizona, Tucson, AZ 85724, USA; Department of Biomedical Engineering, the University of Arizona, Tucson, AZ 85721, USA
| | - Kevin Johnson
- Department of Medical Imaging, the University of Arizona, Tucson, AZ 85724, USA
| | | | | | - Diego R Martin
- Department of Medical Imaging, the University of Arizona, Tucson, AZ 85724, USA
| | - Maria I Altbach
- Department of Medical Imaging, the University of Arizona, Tucson, AZ 85724, USA; Department of Biomedical Engineering, the University of Arizona, Tucson, AZ 85721, USA.
| |
Collapse
|
2
|
Roberts NT, Hinshaw LA, Colgan TJ, Ii T, Hernando D, Reeder SB. B 0 and B 1 inhomogeneities in the liver at 1.5 T and 3.0 T. Magn Reson Med 2020; 85:2212-2220. [PMID: 33107109 DOI: 10.1002/mrm.28549] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 09/02/2020] [Accepted: 09/18/2020] [Indexed: 12/17/2022]
Abstract
PURPOSE The purpose of this work is to characterize the magnitude and variability of B0 and B1 inhomogeneities in the liver in large cohorts of patients at both 1.5 T and 3.0 T. METHODS Volumetric B0 and B1 maps were acquired over the liver of patients presenting for routine abdominal MRI. Regions of interest were drawn in the nine Couinaud segments of the liver, and the average value was recorded. Magnitude and variation of measured averages in each segment were reported across all patients. RESULTS A total of 316 B0 maps and 314 B1 maps, acquired at 1.5 T and 3.0 T on a variety of GE Healthcare MRI systems in 630 unique exams, were identified, analyzed, and, in the interest of reproducible research, de-identified and made public. Measured B0 inhomogeneities ranged (5th-95th percentiles) from -31.7 Hz to 164.0 Hz for 3.0 T (-14.5 Hz to 81.3 Hz at 1.5 T), while measured B1 inhomogeneities (ratio of actual over prescribed flip angle) ranged from 0.59 to 1.13 for 3.0 T (0.83 to 1.11 at 1.5 T). CONCLUSION This study provides robust characterization of B0 and B1 inhomogeneities in the liver to guide the development of imaging applications and protocols. Field strength, bore diameter, and sex were determined to be statistically significant effects for both B0 and B1 uniformity. Typical clinical liver imaging at 3.0 T should expect B0 inhomogeneities ranging from approximately -100 Hz to 250 Hz (-50 Hz to 150 Hz at 1.5 T) and B1 inhomogeneities ranging from approximately 0.4 to 1.3 (0.7 to 1.2 at 1.5 T).
Collapse
Affiliation(s)
- Nathan T Roberts
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Louis A Hinshaw
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Timothy J Colgan
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Takanori Ii
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Radiology, University of Yamanashi, Yamanashi, Japan
| | - Diego Hernando
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Scott B Reeder
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Emergency Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA
| |
Collapse
|
3
|
Robb JS, Hu C, Peters DC. Interleaved, undersampled radial multiple-acquisition steady-state free precession for improved left atrial cine imaging. Magn Reson Med 2020; 83:1721-1729. [PMID: 31605555 PMCID: PMC6982567 DOI: 10.1002/mrm.28036] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2019] [Revised: 08/31/2019] [Accepted: 09/20/2019] [Indexed: 11/10/2022]
Abstract
PURPOSE Balanced steady-state free precession (bSSFP) left atrial (LA) cine suffers from off-resonance artifacts, particularly in the pulmonary veins (PVs). Linear combination or multiple-acquisition SSFP (MA-SSFP) effectively removes banding but greatly increases scan time. We hypothesized that MA-SSFP with interleaved radial undersampling, where each phase-cycling is acquired with an interleaved set of radial projections, would improve image quality of LA cine with a small increase of scan time and streak artefacts. METHODS Undersampled radial MA-SSFP with and without interleaving was compared with fully sampled radial bSSFP by means of simulations, phantoms, and in vivo imaging. Ten healthy subjects were imaged on a 3T scanner, with bSSFP and MA-SSFP cine of the left atrium, and B0-mapping. Images were assessed (1 = worst, 5 = best) by 2 independent readers, with respect to 5 qualitative criteria and apparent signal-to-noise ratio. RESULTS In healthy subjects, off-resonance differed from the right inferior PVs to the LA cavity by 163 Hz ± 73 Hz at 3T. Compared with fully sampled radial bSSFP, interleaved radial MA-SSFP significantly improved image quality with respect to off-resonance artifacts (3.8 ± 0.6 versus 2.3 ± 1.0; P = 0.005), PV conspicuity (2.8 ± 1.0 versus 4.3 ± 0.5; P = 0.005), and the number of visualized PVs (1.7 ± 0.4 versus 0.9 ± 0.7; P = 0.008), although with greater streak artifacts (3.4 ± 0.4 versus 4.9 ± 0.2; P = 0.004) and lower measured apparent signal-to-noise ratio (24 ± 9 versus 69 ± 36; P = 0.002). Flow artifacts were similar. Interleaved radial MA-SSFP reduced streaking artifacts and increased apparent signal-to-noise ratio versus noninterleaved radial. CONCLUSIONS Interleaved radial MA-SSFP cine reduces banding artifacts with an acceptable increase of scan time and streak artifacts. The proposed technique improves the LA and PV visualization in bSSFP cine imaging.
Collapse
Affiliation(s)
| | - Chenxi Hu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, CT, USA
| | - Dana C. Peters
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, CT, USA
| |
Collapse
|
4
|
Slawig A, Wech T, Ratz V, Neubauer H, Bley T, Köstler H. Frequency-modulated bSSFP for phase-sensitive separation of water and fat. Magn Reson Imaging 2018; 53:82-88. [PMID: 29902564 DOI: 10.1016/j.mri.2018.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2017] [Revised: 04/27/2018] [Accepted: 06/10/2018] [Indexed: 10/28/2022]
Abstract
Our study proposes the use of a frequency-modulated acquisition which suppresses banding artefacts in combination with a phase-sensitive water-fat separation algorithm. The performance of the phase-sensitive separation for standard bSSFP, complex sum combination thereof, and frequency-modulated bSSFP were compared in in vivo measurements of the upper and lower legs at 1.5 and 3 T. It is shown, that the standard acquisition suffered from banding artefacts and major swaps between tissues. The dual-acquisition bSSFP could alleviate banding artefacts and only minor swaps occurred, but it comes at the expense of a doubled acquisition. In the frequency-modulated acquisitions all banding artefacts and the associated phase jumps were eliminated and no swaps between tissues occurred. It therefore provides a means to robustly separate water and fat, in one single radial bSSFP scan, using the phase-sensitive approach, even in the presence of high field inhomogeneities.
Collapse
Affiliation(s)
- Anne Slawig
- University of Würzburg, Department of Diagnostic and Interventional Radiology, Oberdürrbacher Str. 6, 97080 Würzburg, Germany.
| | - Tobias Wech
- University of Würzburg, Department of Diagnostic and Interventional Radiology, Oberdürrbacher Str. 6, 97080 Würzburg, Germany
| | - Valentin Ratz
- University of Würzburg, Department of Diagnostic and Interventional Radiology, Oberdürrbacher Str. 6, 97080 Würzburg, Germany
| | - Henning Neubauer
- University of Würzburg, Department of Diagnostic and Interventional Radiology, Oberdürrbacher Str. 6, 97080 Würzburg, Germany; SRH Clinic of Radiology, Albert-Schweitzer-Str. 2, 98527 Suhl, Germany
| | - Thorsten Bley
- University of Würzburg, Department of Diagnostic and Interventional Radiology, Oberdürrbacher Str. 6, 97080 Würzburg, Germany
| | - Herbert Köstler
- University of Würzburg, Department of Diagnostic and Interventional Radiology, Oberdürrbacher Str. 6, 97080 Würzburg, Germany
| |
Collapse
|
5
|
Milshteyn E, von Morze C, Reed GD, Shang H, Shin PJ, Zhu Z, Chen HY, Bok R, Goga A, Kurhanewicz J, Larson PEZ, Vigneron DB. Development of high resolution 3D hyperpolarized carbon-13 MR molecular imaging techniques. Magn Reson Imaging 2017; 38:152-162. [PMID: 28077268 PMCID: PMC5360530 DOI: 10.1016/j.mri.2017.01.003] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2016] [Revised: 01/05/2017] [Accepted: 01/06/2017] [Indexed: 01/08/2023]
Abstract
The goal of this project was to develop and apply techniques for T2 mapping and 3D high resolution (1.5mm isotropic; 0.003cm3) 13C imaging of hyperpolarized (HP) probes [1-13C]lactate, [1-13C]pyruvate, [2-13C]pyruvate, and [13C,15N2]urea in vivo. A specialized 2D bSSFP sequence was implemented on a clinical 3T scanner and used to obtain the first high resolution T2 maps of these different hyperpolarized compounds in both rats and tumor-bearing mice. These maps were first used to optimize timings for highest SNR for single time-point 3D bSSFP acquisitions with a 1.5mm isotropic spatial resolution of normal rats. This 3D acquisition approach was extended to serial dynamic imaging with 2-fold compressed sensing acceleration without changing spatial resolution. The T2 mapping experiments yielded measurements of T2 values of >1s for all compounds within rat kidneys/vasculature and TRAMP tumors, except for [2-13C]pyruvate which was ~730ms and ~320ms, respectively. The high resolution 3D imaging enabled visualization the biodistribution of [1-13C]lactate, [1-13C]pyruvate, and [2-13C]pyruvate within different kidney compartments as well as in the vasculature. While the mouse anatomy is smaller, the resolution was also sufficient to image the distribution of all compounds within kidney, vasculature, and tumor. The development of the specialized 3D sequence with compressed sensing provided improved structural and functional assessments at a high (0.003cm3) spatial and 2s temporal resolution in vivo utilizing HP 13C substrates by exploiting their long T2 values. This 1.5mm isotropic resolution is comparable to 1H imaging and application of this approach could be extended to future studies of uptake, metabolism, and perfusion in cancer and other disease models and may ultimately be of value for clinical imaging.
Collapse
Affiliation(s)
- Eugene Milshteyn
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA; UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, San Francisco and University of California, Berkeley, CA, USA
| | - Cornelius von Morze
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | | | - Hong Shang
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA; UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, San Francisco and University of California, Berkeley, CA, USA
| | - Peter J Shin
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Zihan Zhu
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA; UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, San Francisco and University of California, Berkeley, CA, USA
| | - Hsin-Yu Chen
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA; UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, San Francisco and University of California, Berkeley, CA, USA
| | - Robert Bok
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Andrei Goga
- Department of Cell and Tissue Biology, University of California, San Francisco, CA, USA
| | - John Kurhanewicz
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA; UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, San Francisco and University of California, Berkeley, CA, USA
| | - Peder E Z Larson
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA; UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, San Francisco and University of California, Berkeley, CA, USA
| | - Daniel B Vigneron
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA; UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, San Francisco and University of California, Berkeley, CA, USA.
| |
Collapse
|
6
|
Slawig A, Wech T, Ratz V, Tran-Gia J, Neubauer H, Bley T, Köstler H. Multifrequency reconstruction for frequency-modulated bSSFP. Magn Reson Med 2017; 78:2226-2235. [DOI: 10.1002/mrm.26630] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2016] [Revised: 12/02/2016] [Accepted: 01/09/2017] [Indexed: 11/10/2022]
Affiliation(s)
- Anne Slawig
- Department of Diagnostic and Interventional Radiology; University of Würzburg; Würzburg Germany
| | - Tobias Wech
- Department of Diagnostic and Interventional Radiology; University of Würzburg; Würzburg Germany
| | - Valentin Ratz
- Department of Diagnostic and Interventional Radiology; University of Würzburg; Würzburg Germany
| | - Johannes Tran-Gia
- Department of Diagnostic and Interventional Radiology; University of Würzburg; Würzburg Germany
- Department of Nuclear Medicine; University of Würzburg; Würzburg Germany
| | - Henning Neubauer
- Department of Diagnostic and Interventional Radiology; University of Würzburg; Würzburg Germany
| | - Thorsten Bley
- Department of Diagnostic and Interventional Radiology; University of Würzburg; Würzburg Germany
| | - Herbert Köstler
- Department of Diagnostic and Interventional Radiology; University of Würzburg; Würzburg Germany
| |
Collapse
|
7
|
Ilicak E, Senel LK, Biyik E, Çukur T. Profile-encoding reconstruction for multiple-acquisition balanced steady-state free precession imaging. Magn Reson Med 2016; 78:1316-1329. [DOI: 10.1002/mrm.26507] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2016] [Revised: 09/02/2016] [Accepted: 09/21/2016] [Indexed: 11/12/2022]
Affiliation(s)
- Efe Ilicak
- Department of Electrical and Electronics Engineering; Bilkent University; Ankara Turkey
- National Magnetic Resonance Research Center (UMRAM); Bilkent University; Ankara Turkey
| | - Lutfi Kerem Senel
- Department of Electrical and Electronics Engineering; Bilkent University; Ankara Turkey
| | - Erdem Biyik
- Department of Electrical and Electronics Engineering; Bilkent University; Ankara Turkey
| | - Tolga Çukur
- Department of Electrical and Electronics Engineering; Bilkent University; Ankara Turkey
- National Magnetic Resonance Research Center (UMRAM); Bilkent University; Ankara Turkey
- Neuroscience Program, Graduate School of Engineering and Science; Bilkent University; Ankara Turkey
| |
Collapse
|
8
|
Wang Y, Shao X, Martin T, Moeller S, Yacoub E, Wang DJJ. Phase-cycled simultaneous multislice balanced SSFP imaging with CAIPIRINHA for efficient banding reduction. Magn Reson Med 2015; 76:1764-1774. [PMID: 26667600 DOI: 10.1002/mrm.26076] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2015] [Revised: 11/13/2015] [Accepted: 11/13/2015] [Indexed: 11/08/2022]
Abstract
PURPOSE To present a time-efficient technique for banding reduction in balanced steady-state free precession (bSSFP) imaging using phase-cycled simultaneous multislice (SMS) acquisition with CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration). THEORY The proposed technique exploits the inherent phase modulation of SMS imaging with CAIPIRINHA to acquire multiple phase-cycled images, which can be combined for efficient banding reduction within the same scan time of a single-band bSSFP scan. METHODS Bloch equation simulation, phantom and in vivo brain, abdominal and cardiac imaging experiments were performed on healthy volunteers at 3T using multi-channel head and body array coils with SMS acceleration factors of two to four. The performance of banding reduction was quantitatively evaluated based on the percent ripple of signal distribution and signal-to-noise ratio (SNR) efficiency in both phantom and human studies. RESULTS The banding artifact was successfully removed or suppressed using phase-cycled SMS bSSFP imaging across SMS factors of two to four. The performance of banding reduction improved with higher SMS factors along with increased SNR efficiency. CONCLUSION Phase-cycled SMS bSSFP with CAIPIRINHA is a promising technique for efficient band reduction in bSSFP without prolonged scan time. Further evaluation of this technique in clinical applications is warranted. Magn Reson Med 76:1764-1774, 2016. © 2015 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Yi Wang
- Laboratory of FMRI Technology (LOFT), Department of Neurology, University of California Los Angeles, Los Angeles, California, USA
| | - Xingfeng Shao
- Laboratory of FMRI Technology (LOFT), Department of Neurology, University of California Los Angeles, Los Angeles, California, USA
| | - Thomas Martin
- Laboratory of FMRI Technology (LOFT), Department of Neurology, University of California Los Angeles, Los Angeles, California, USA
| | - Steen Moeller
- Center of Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
| | - Essa Yacoub
- Center of Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
| | - Danny J J Wang
- Laboratory of FMRI Technology (LOFT), Department of Neurology, University of California Los Angeles, Los Angeles, California, USA
| |
Collapse
|
9
|
Ribot EJ, Wecker D, Trotier AJ, Dallaudière B, Lefrançois W, Thiaudière E, Franconi JM, Miraux S. Water Selective Imaging and bSSFP Banding Artifact Correction in Humans and Small Animals at 3T and 7T, Respectively. PLoS One 2015; 10:e0139249. [PMID: 26426849 PMCID: PMC4591352 DOI: 10.1371/journal.pone.0139249] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Accepted: 09/09/2015] [Indexed: 11/18/2022] Open
Abstract
INTRODUCTION The purpose of this paper is to develop an easy method to generate both fat signal and banding artifact free 3D balanced Steady State Free Precession (bSSFP) images at high magnetic field. METHODS In order to suppress fat signal and bSSFP banding artifacts, two or four images were acquired with the excitation frequency of the water-selective binomial radiofrequency pulse set On Resonance or shifted by a maximum of 3/4TR. Mice and human volunteers were imaged at 7 T and 3 T, respectively to perform whole-body and musculoskeletal imaging. "Sum-Of-Square" reconstruction was performed and combined or not with parallel imaging. RESULTS The frequency selectivity of 1-2-3-2-1 or 1-3-3-1 binomial pulses was preserved after (3/4TR) frequency shifting. Consequently, whole body small animal 3D imaging was performed at 7 T and enabled visualization of small structures within adipose tissue like lymph nodes. In parallel, this method allowed 3D musculoskeletal imaging in humans with high spatial resolution at 3 T. The combination with parallel imaging allowed the acquisition of knee images with ~500 μm resolution images in less than 2 min. In addition, ankles, full head coverage and legs of volunteers were imaged, demonstrating the possible application of the method also for large FOV. CONCLUSION In conclusion, this robust method can be applied in small animals and humans at high magnetic fields. The high SNR and tissue contrast obtained in short acquisition times allows to prescribe bSSFP sequence for several preclinical and clinical applications.
Collapse
Affiliation(s)
- Emeline J. Ribot
- Centre de Résonance Magnétique des Systèmes Biologiques, UMR 5536, CNRS/University Bordeaux, Bordeaux, France
- * E-mail:
| | | | - Aurélien J. Trotier
- Centre de Résonance Magnétique des Systèmes Biologiques, UMR 5536, CNRS/University Bordeaux, Bordeaux, France
| | - Benjamin Dallaudière
- Centre de Résonance Magnétique des Systèmes Biologiques, UMR 5536, CNRS/University Bordeaux, Bordeaux, France
| | - William Lefrançois
- Centre de Résonance Magnétique des Systèmes Biologiques, UMR 5536, CNRS/University Bordeaux, Bordeaux, France
| | - Eric Thiaudière
- Centre de Résonance Magnétique des Systèmes Biologiques, UMR 5536, CNRS/University Bordeaux, Bordeaux, France
| | - Jean-Michel Franconi
- Centre de Résonance Magnétique des Systèmes Biologiques, UMR 5536, CNRS/University Bordeaux, Bordeaux, France
| | - Sylvain Miraux
- Centre de Résonance Magnétique des Systèmes Biologiques, UMR 5536, CNRS/University Bordeaux, Bordeaux, France
| |
Collapse
|