1
|
Degenhardt K, Schmidt S, Aigner CS, Kratzer FJ, Seiter DP, Mueller M, Kolbitsch C, Nagel AM, Wieben O, Schaeffter T, Schulz-Menger J, Schmitter S. Toward accurate and fast velocity quantification with 3D ultrashort TE phase-contrast imaging. Magn Reson Med 2024; 91:1994-2009. [PMID: 38174601 DOI: 10.1002/mrm.29978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 11/28/2023] [Accepted: 11/28/2023] [Indexed: 01/05/2024]
Abstract
PURPOSE Traditional phase-contrast MRI is affected by displacement artifacts caused by non-synchronized spatial- and velocity-encoding time points. The resulting inaccurate velocity maps can affect the accuracy of derived hemodynamic parameters. This study proposes and characterizes a 3D radial phase-contrast UTE (PC-UTE) sequence to reduce displacement artifacts. Furthermore, it investigates the displacement of a standard Cartesian flow sequence by utilizing a displacement-free synchronized-single-point-imaging MR sequence (SYNC-SPI) that requires clinically prohibitively long acquisition times. METHODS 3D flow data was acquired at 3T at three different constant flow rates and varying spatial resolutions in a stenotic aorta phantom using the proposed PC-UTE, a Cartesian flow sequence, and a SYNC-SPI sequence as reference. Expected displacement artifacts were calculated from gradient timing waveforms and compared to displacement values measured in the in vitro flow experiments. RESULTS The PC-UTE sequence reduces displacement and intravoxel dephasing, leading to decreased geometric distortions and signal cancellations in magnitude images, and more spatially accurate velocity quantification compared to the Cartesian flow acquisitions; errors increase with velocity and higher spatial resolution. CONCLUSION PC-UTE MRI can measure velocity vector fields with greater accuracy than Cartesian acquisitions (although pulsatile fields were not studied) and shorter scan times than SYNC-SPI. As such, this approach is superior to traditional Cartesian 3D and 4D flow MRI when spatial misrepresentations cannot be tolerated, for example, when computational fluid dynamics simulations are compared to or combined with in vitro or in vivo measurements, or regional parameters such as wall shear stress are of interest.
Collapse
Affiliation(s)
- Katja Degenhardt
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Berlin, Germany
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Simon Schmidt
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Christoph S Aigner
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Berlin, Germany
| | - Fabian J Kratzer
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Daniel P Seiter
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
| | - Max Mueller
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Christoph Kolbitsch
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Berlin, Germany
| | - Armin M Nagel
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Oliver Wieben
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
- Department of Radiology, University of Wisconsin Madison, Madison, Wisconsin, USA
| | - Tobias Schaeffter
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Berlin, Germany
- School of Imaging Science and Biomedical Engineering, King's College London, London, United Kingdom
- Department of Medical Engineering, Technical University of Berlin, Berlin, Germany
| | - Jeanette Schulz-Menger
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max-Delbrueck Center for Molecular Medicine, Berlin, Germany
- DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
- Department of Cardiology and Nephrology, HELIOS Hospital Berlin-Buch, Berlin, Germany
| | - Sebastian Schmitter
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Berlin, Germany
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
2
|
Corrado PA, Wentland AL, Starekova J, Dhyani A, Goss KN, Wieben O. Fully automated intracardiac 4D flow MRI post-processing using deep learning for biventricular segmentation. Eur Radiol 2022; 32:5669-5678. [PMID: 35175379 DOI: 10.1007/s00330-022-08616-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 12/14/2021] [Accepted: 01/26/2022] [Indexed: 11/04/2022]
Abstract
OBJECTIVES 4D flow MRI allows for a comprehensive assessment of intracardiac blood flow, useful for assessing cardiovascular diseases, but post-processing requires time-consuming ventricular segmentation throughout the cardiac cycle and is prone to subjective errors. Here, we evaluate the use of automatic left and right ventricular (LV and RV) segmentation based on deep learning (DL) network that operates on short-axis cine bSSFP images. METHODS A previously published DL network was fine-tuned via retraining on a local database of 106 subjects scanned at our institution. In 26 test subjects, the ventricles were segmented automatically by the network and manually by 3 human observers on bSSFP MRI. The bSSFP images were then registered to the corresponding 4D flow images to apply the segmentation to 4D flow velocity data. Dice coefficients and the relative deviation between measurements (automatic vs. manual and interobserver manual) of various hemodynamic parameters were assessed. RESULTS The automated segmentation resulted in similar Dice scores (LV: 0.92, RV: 0.86) and lower relative deviations from manual segmentation in left ventricular (LV) average kinetic energy (KE) (8%) and RV KE (15%) than the Dice scores (LV: 0.91, RV: 0.87) and relative deviations between manual segmentation observers (LV KE: 11%, p = 0.01; RV KE: 19%, p = 0.03). CONCLUSIONS The automated post-processing method using deep learning resulted in hemodynamic measurements that differ from a manual observer's measurements equally or less than the variation between manual observers. This approach can be used to decrease post-processing time on intraventricular 4D flow data and mitigate interobserver variability. KEY POINTS • Our proposed method allows for fully automated post-processing of intraventricular 4D flow MRI data. • Our method resulted in hemodynamic measurements that matched those derived from manual segmentation equally as well as interobserver variability. • Our method can be used to greatly accelerate intraventricular 4D flow post-processing and improve interobserver repeatability.
Collapse
Affiliation(s)
- Philip A Corrado
- University of Wisconsin-Madison, 1111 Highland Ave, Madison, WI, 53705, USA.
| | - Andrew L Wentland
- University of Wisconsin-Madison, 1111 Highland Ave, Madison, WI, 53705, USA
| | - Jitka Starekova
- University of Wisconsin-Madison, 1111 Highland Ave, Madison, WI, 53705, USA
| | - Archana Dhyani
- University of Wisconsin-Madison, 1111 Highland Ave, Madison, WI, 53705, USA
| | - Kara N Goss
- UT Southwestern Medical Center, 5323 Harry Hines Blvd., Dallas, TX, 75390, USA
| | - Oliver Wieben
- University of Wisconsin-Madison, 1111 Highland Ave, Madison, WI, 53705, USA
| |
Collapse
|
3
|
Improved Segmentation of Cardiac MRI using efficient Pre-Processing Technique. JOURNAL OF INFORMATION TECHNOLOGY RESEARCH 2022. [DOI: 10.4018/jitr.299932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Cardiac Magnetic Resonance Imaging is a popular non-invasive technique used for assessing the cardiac performance. Automating the segmentation helps in increased diagnosis accuracy in considerably less time and effort. In this paper a novel approach has been proposed to improve the automated segmentation process by increasing the accuracy of segmentation and laying focus on efficient pre-processing of the cardiac Magnetic Resonance (MR) image. The pre-processing module in the proposed method includes noise estimation and efficient denoising of images using discrete total variation based Non local means method.Segmentation accuracy is evaluated using measures such as average perpendicular distance and dice similarity coefficient. The performance of all the segmentation techniques is improved. Further segmentation comparison has also been performed using other state-of-the art noise removal techniques for pre-processing and it was observed that the proposed pre-processing technique outperformed other noise removal techniques in improving the segmentation accuracy.
Collapse
|
4
|
Kim D, Eisenmenger L, Turski P, Johnson KM. Simultaneous 3D-TOF angiography and 4D-flow MRI with enhanced flow signal using multiple overlapping thin slab acquisition and magnetization transfer. Magn Reson Med 2021; 87:1401-1417. [PMID: 34708445 DOI: 10.1002/mrm.29060] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 10/03/2021] [Accepted: 10/08/2021] [Indexed: 12/29/2022]
Abstract
PURPOSE To investigate the fusion of 3D time-of-flight principles into 4D-flow MRI to enhance vessel contrast and signal without an exogenous contrast agent, enabling simultaneous in-flow based angiograms. METHODS A 4D-flow MRI technique was developed consisting of multiple overlapping slabs with intermittent magnetization transfer preparation. The scan time penalty associated with multiple slab acquisitions was mitigated by using undersampled distributed spiral trajectories and compressed sensing reconstruction. A flow phantom was used to characterize in-flow enhancement, velocity noise improvement, and flow rate measurements against the single-slab 4D-flow MRI. In a patient-volunteer cohort (n = 15), magnitude-based angiograms were radiologically evaluated against 3D time-of-flight, and velocity measurements were compared pixel-wise against single-slab and contrast-enhanced 4D-flow MRI. RESULTS Multiple-slab acquisitions, together with magnetization transfer preparation, substantially improved vessel signal, contrast, and vessel conspicuity in magnitude angiograms. Both clinical 3D time-of-flight and the proposed technique produced equivalent vessel depictions with no statistically significant difference (p < .1). Both techniques also produced clear depictions of brain aneurysms in all patients; however, very small vessels tended to show reduced conspicuity in the proposed technique. Velocity measurements agreed with contrast-enhanced and single-slab scans with high correlations (R2 = 0.941-0.974) and agreements (slopes = 0.994-1.071). Slab boundary and magnetization transfer-related artifacts were not observed in velocity measurements, and velocity noise was reduced with in-flow enhancement over single-slab scans (phantom). CONCLUSION The vessel signal and contrast can be improved in 4D-flow MRI without exogenous contrast agents by utilizing in-flow enhancement, efficient sampling, and compressed sensing. The in-flow enhancement also enables simultaneous 3D time-of-flight angiograms useful for flow quantification and diagnosis.
Collapse
Affiliation(s)
- Dahan Kim
- Department of Physics, University of Wisconsin, Madison, Wisconsin, USA.,Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Laura Eisenmenger
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Patrick Turski
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Kevin M Johnson
- Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.,Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| |
Collapse
|
5
|
Macdonald JA, Roberts GS, Corrado PA, Beshish AG, Haraldsdottir K, Barton GP, Goss KN, Eldridge MW, Francois CJ, Wieben O. Exercise-induced irregular right heart flow dynamics in adolescents and young adults born preterm. J Cardiovasc Magn Reson 2021; 23:116. [PMID: 34670573 PMCID: PMC8529801 DOI: 10.1186/s12968-021-00816-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Accepted: 09/24/2021] [Indexed: 01/09/2023] Open
Abstract
BACKGROUND Preterm birth has been linked to an elevated risk of heart failure and cardiopulmonary disease later in life. With improved neonatal care and survival, most infants born preterm are now reaching adulthood. In this study, we used 4D flow cardiovascular magnetic resonance (CMR) coupled with an exercise challenge to assess the impact of preterm birth on right heart flow dynamics in otherwise healthy adolescents and young adults who were born preterm. METHODS Eleven young adults and 17 adolescents born preterm (< 32 weeks of gestation and < 1500 g birth weight) were compared to 11 young adult and 18 adolescent age-matched controls born at term. Stroke volume, cardiac output, and flow in the main pulmonary artery were quantified with 4D flow CMR. Kinetic energy and vorticity were measured in the right ventricle. All parameters were measured at rest and during exercise at a power corresponding to 70% VO2max for each subject. Multivariate linear regression was used to perform age-adjusted term-preterm comparisons. RESULTS With exercise, stroke volume increased 10 ± 21% in term controls and decreased 4 ± 18% in preterm born subjects (p = 0.007). This resulted in significantly reduced capacity to increase cardiac output in response to exercise stress for the preterm group (58 ± 26% increase in controls, 36 ± 27% increase in preterm, p = 0.004). Elevated kinetic energy (KEterm = 71 ± 22 nJ, KEpreterm = 87 ± 38 nJ, p = 0.03) and vorticity (ωterm = 79 ± 16 s-1, ωpreterm = 94 ± 32 s-1, p = 0.01) during diastole in the right ventricle (RV) suggested altered RV flow dynamics in the preterm subjects. Streamline visualizations showed altered structure to the diastolic filling vortices in those born preterm. CONCLUSIONS For the participants examined here, preterm birth appeared to result in altered right-heart flow dynamics as early as adolescence, especially during diastole. Future studies should evaluate whether the altered dynamics identified here evolves into cardiopulmonary disease later in life. Trial registration None.
Collapse
Affiliation(s)
| | - Grant S Roberts
- Medical Physics, University of Wisconsin-Madison, Madison, USA
| | | | - Arij G Beshish
- Pediatrics, University of Wisconsin-Madison, Madison, USA
| | | | | | - Kara N Goss
- Pediatrics, University of Wisconsin-Madison, Madison, USA
- Medicine, University of Wisconsin-Madison, Madison, USA
| | - Marlowe W Eldridge
- Pediatrics, University of Wisconsin-Madison, Madison, USA
- Biomedical Engineering, University of Wisconsin-Madison, Madison, USA
| | | | - Oliver Wieben
- Medical Physics, University of Wisconsin-Madison, Madison, USA
- Biomedical Engineering, University of Wisconsin-Madison, Madison, USA
- Radiology, University of Wisconsin-Madison, Madison, USA
| |
Collapse
|
6
|
Ngo MT, Lee UY, Ha H, Jung J, Lee DH, Kwak HS. Improving Blood Flow Visualization of Recirculation Regions at Carotid Bulb in 4D Flow MRI Using Semi-Automatic Segmentation with ITK-SNAP. Diagnostics (Basel) 2021; 11:diagnostics11101890. [PMID: 34679588 PMCID: PMC8534781 DOI: 10.3390/diagnostics11101890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 10/06/2021] [Accepted: 10/10/2021] [Indexed: 11/16/2022] Open
Abstract
Assessment of carotid bulb hemodynamics using four-dimensional (4D) flow magnetic resonance imaging (MRI) requires accurate segmentation of recirculation regions that is frequently hampered by limited resolution. This study aims to improve the accuracy of 4D flow MRI carotid bulb segmentation and subsequent recirculation regions analysis. Time-of-flight (TOF) MRI and 4D flow MRI were performed on bilateral carotid artery bifurcations in seven healthy volunteers. TOF-MRI data was segmented into 3D geometry for computational fluid dynamics (CFD) simulations. ITK-SNAP segmentation software was included in the workflow for the semi-automatic generation of 4D flow MRI angiographic data. This study compared the velocities calculated at the carotid bifurcations and the 3D blood flow visualization at the carotid bulbs obtained by 4D flow MRI and CFD. By applying ITK-SNAP segmentation software, an obvious improvement in the 4D flow MRI visualization of the recirculation regions was observed. The 4D flow MRI images of the recirculation flow characteristics of the carotid artery bulbs coincided with the CFD. A reasonable agreement was found in terms of velocity calculated at the carotid bifurcation between CFD and 4D flow MRI. However, the dispersion of velocity data points relative to the local errors of measurement in 4D flow MRI remains. Our proposed strategy showed the feasibility of improving recirculation regions segmentation and the potential for reliable blood flow visualization in 4D flow MRI. However, quantitative analysis of recirculation regions in 4D flow MRI with ITK-SNAP should be enhanced for use in clinical situations.
Collapse
Affiliation(s)
- Minh Tri Ngo
- Department of Radiology of Hue Central Hospital, Hue, Thua Thien Hue 530000, Vietnam;
| | - Ui Yun Lee
- Division of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeon-ju 54896, Korea; (U.Y.L.); (J.J.)
| | - Hojin Ha
- Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon 24341, Korea;
| | - Jinmu Jung
- Division of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeon-ju 54896, Korea; (U.Y.L.); (J.J.)
- Hemorheology Research Institute, Jeonbuk National University, Jeon-ju 54896, Korea
| | - Dong Hwan Lee
- Division of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeon-ju 54896, Korea; (U.Y.L.); (J.J.)
- Hemorheology Research Institute, Jeonbuk National University, Jeon-ju 54896, Korea
- Correspondence: (D.H.L.); (H.S.K.); Tel.: +82-63-270-3998 (D.H.L.); +82-63-250-2582 (H.S.K.)
| | - Hyo Sung Kwak
- Department of Radiology and Research Institute of Clinical Medicine of Jeonbuk National University, Biomedical Research Institute of Jeonbuk National University Hospital, Jeon-ju 54907, Korea
- Correspondence: (D.H.L.); (H.S.K.); Tel.: +82-63-270-3998 (D.H.L.); +82-63-250-2582 (H.S.K.)
| |
Collapse
|
7
|
Corrado PA, Barton GP, Macdonald JA, François CJ, Eldridge MW, Goss KN, Wieben O. Altered Right Ventricular Filling at Four-dimensional Flow MRI in Young Adults Born Prematurely. Radiol Cardiothorac Imaging 2021; 3:e200618. [PMID: 34250493 DOI: 10.1148/ryct.2021200618] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Revised: 02/08/2021] [Accepted: 04/15/2021] [Indexed: 11/11/2022]
Abstract
Purpose To use four-dimensional (4D) flow MRI to measure intraventricular flow in young adults who were born prematurely to investigate mechanisms that may account for increased heart failure risk in this population. Materials and Methods In this secondary analysis of a prospective study, a total of 56 young adults participated in an observational cardiac 4D flow MRI study from 2016 to 2020. There were 35 participants who had been born moderately to extremely prematurely (birth weight <1500 g or gestational age ≤32 weeks; 23 women; mean age, 26 years ± 4) and 21 term-born participants (11 women; mean age, 25 years ± 3). Participants underwent cardiac MRI, including cine cardiac structure and function assessment, as well as 4D flow MRI. In each ventricle, normalized kinetic energy (KE/end diastolic volume) and flow through the atrioventricular valve were computed and compared between term-born and preterm participants at systolic and diastolic (early diastolic filling rate [E wave] and late diastolic filling [atrial contraction] rate [A wave]) time points by using Wilcoxon rank-sum tests. Results Preterm-born participants had lower right ventricular (RV) E wave/A wave (E/A) KE ratios (2.4 ± 1.7 vs 3.5 ± 1.4; P <.01) and lower E/A peak filling rate ratios (computed from RV volume-time curves; 2.3 ± 1.3 vs 3.5 ± 2.5; P = .03). Additionally, viscous energy dissipation was increased during systole (5.7 µW/mL ± 3.0 vs 4.2 µW/mL ± 1.6; P = .03), increased during late diastole (3.9 µW/mL ± 4.0 vs 2.2 µW/mL ± 1.6; P = .03), and summed over the cardiac cycle (2.4 µJ/mL ± 1.0 vs 1.9 µJ/mL ± 0.6; P = .02) in preterm relative to term participants. Conclusion These results suggest that RV diastolic filling is altered in young adults who were born moderately to severely prematurely.Supplemental material is available for this article. Keywords: Adults, Cardiac, Comparative Studies, MR-Imaging, Right Ventricle © RSNA, 2021.
Collapse
Affiliation(s)
- Philip A Corrado
- Departments of Medical Physics, Radiology, Pediatrics, and Medicine, University of Wisconsin-Madison, Madison, Wis (P.A.C., M.W.E., O.W.); Department of Internal Medicine, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390-8558 (G.P.B., K.N.G.); Department of Radiology, University of Michigan, Ann Arbor, Mich (J.A.M.); and Department of Radiology, Mayo Clinic, Rochester, Minn (C.J.F.)
| | - Gregory P Barton
- Departments of Medical Physics, Radiology, Pediatrics, and Medicine, University of Wisconsin-Madison, Madison, Wis (P.A.C., M.W.E., O.W.); Department of Internal Medicine, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390-8558 (G.P.B., K.N.G.); Department of Radiology, University of Michigan, Ann Arbor, Mich (J.A.M.); and Department of Radiology, Mayo Clinic, Rochester, Minn (C.J.F.)
| | - Jacob A Macdonald
- Departments of Medical Physics, Radiology, Pediatrics, and Medicine, University of Wisconsin-Madison, Madison, Wis (P.A.C., M.W.E., O.W.); Department of Internal Medicine, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390-8558 (G.P.B., K.N.G.); Department of Radiology, University of Michigan, Ann Arbor, Mich (J.A.M.); and Department of Radiology, Mayo Clinic, Rochester, Minn (C.J.F.)
| | - Christopher J François
- Departments of Medical Physics, Radiology, Pediatrics, and Medicine, University of Wisconsin-Madison, Madison, Wis (P.A.C., M.W.E., O.W.); Department of Internal Medicine, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390-8558 (G.P.B., K.N.G.); Department of Radiology, University of Michigan, Ann Arbor, Mich (J.A.M.); and Department of Radiology, Mayo Clinic, Rochester, Minn (C.J.F.)
| | - Marlowe W Eldridge
- Departments of Medical Physics, Radiology, Pediatrics, and Medicine, University of Wisconsin-Madison, Madison, Wis (P.A.C., M.W.E., O.W.); Department of Internal Medicine, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390-8558 (G.P.B., K.N.G.); Department of Radiology, University of Michigan, Ann Arbor, Mich (J.A.M.); and Department of Radiology, Mayo Clinic, Rochester, Minn (C.J.F.)
| | - Kara N Goss
- Departments of Medical Physics, Radiology, Pediatrics, and Medicine, University of Wisconsin-Madison, Madison, Wis (P.A.C., M.W.E., O.W.); Department of Internal Medicine, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390-8558 (G.P.B., K.N.G.); Department of Radiology, University of Michigan, Ann Arbor, Mich (J.A.M.); and Department of Radiology, Mayo Clinic, Rochester, Minn (C.J.F.)
| | - Oliver Wieben
- Departments of Medical Physics, Radiology, Pediatrics, and Medicine, University of Wisconsin-Madison, Madison, Wis (P.A.C., M.W.E., O.W.); Department of Internal Medicine, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390-8558 (G.P.B., K.N.G.); Department of Radiology, University of Michigan, Ann Arbor, Mich (J.A.M.); and Department of Radiology, Mayo Clinic, Rochester, Minn (C.J.F.)
| |
Collapse
|
8
|
Corrado PA, Barton GP, Francois CJ, Wieben O, Goss KN. Sildenafil administration improves right ventricular function on 4D flow MRI in young adults born premature. Am J Physiol Heart Circ Physiol 2021; 320:H2295-H2304. [PMID: 33861148 PMCID: PMC8289359 DOI: 10.1152/ajpheart.00824.2020] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Revised: 03/30/2021] [Accepted: 04/13/2021] [Indexed: 11/22/2022]
Abstract
Extreme preterm birth conveys an elevated risk of heart failure by young adulthood. Smaller biventricular chamber size, diastolic dysfunction, and pulmonary hypertension may contribute to reduced ventricular-vascular coupling. However, how hemodynamic manipulations may affect right ventricular (RV) function and coupling remains unknown. As a pilot study, 4D flow MRI was used to assess the effect of afterload reduction and heart rate reduction on cardiac hemodynamics and function. Young adults born premature were administered sildenafil (a pulmonary vasodilator) and metoprolol (a β blocker) on separate days, and MRI with 4D flow completed before and after each drug administration. Endpoints include cardiac index (CI), direct flow fractions, and ventricular kinetic energy including E/A wave kinetic energy ratio. Sildenafil resulted in a median CI increase of 0.24 L/min/m2 (P = 0.02), mediated through both an increase in heart rate (HR) and stroke volume. Although RV ejection fraction improved only modestly, there was a significant increase (4% of end diastolic volume) in RV direct flow fraction (P = 0.04), consistent with hemodynamic improvement. Metoprolol administration resulted in a 5-beats/min median decrease in HR (P = 0.01), a 0.37 L/min/m2 median decrease in CI (P = 0.04), and a reduction in time-averaged kinetic energy (KE) in both ventricles (P < 0.01), despite increased RV diastolic E/A KE ratio (P = 0.04). Despite reduced right atrial workload, metoprolol significantly depressed overall cardiac systolic function. Sildenafil, however, increased CI and improved RV function, as quantified by the direct flow fraction. The preterm heart appears dependent on HR but sensitive to RV afterload manipulations.NEW & NOTEWORTHY We assessed the effect of right ventricular afterload reduction with sildenafil and heart rate reduction with metoprolol on cardiac hemodynamics and function in young adults born premature using 4D flow MRI. Metoprolol depressed cardiac function, whereas sildenafil improved cardiac function including right ventricular direct flow fraction by 4D flow, consistent with hemodynamic improvement. This suggests that the preterm heart is dependent on heart rate and sensitive to right ventricular afterload changes.
Collapse
Affiliation(s)
- Philip A Corrado
- Department of Medical Physics, University of Wisconsin-Madison, School of Medicine and Public Health, Madison, Wisconsin
| | - Gregory P Barton
- Department of Medical Physics, University of Wisconsin-Madison, School of Medicine and Public Health, Madison, Wisconsin
- Department of Medicine, University of Texas Southwestern, Dallas, Texas
| | - Christopher J Francois
- Department of Radiology, University of Wisconsin-Madison, School of Medicine and Public Health, Madison, Wisconsin
- Department of Radiology, Mayo Clinic, Rochester, Minnesota
| | - Oliver Wieben
- Department of Medical Physics, University of Wisconsin-Madison, School of Medicine and Public Health, Madison, Wisconsin
- Department of Radiology, University of Wisconsin-Madison, School of Medicine and Public Health, Madison, Wisconsin
| | - Kara N Goss
- Department of Medicine, University of Texas Southwestern, Dallas, Texas
- Department of Pediatrics, University of Wisconsin-Madison, School of Medicine and Public Health, Madison, Wisconsin
- Department of Medicine. University of Wisconsin-Madison, School of Medicine and Public Health, Madison, Wisconsin
| |
Collapse
|
9
|
Macdonald JA, Beshish AG, Corrado PA, Barton GP, Goss KN, Eldridge MW, François CJ, Wieben O. Feasibility of Cardiovascular Four-dimensional Flow MRI during Exercise in Healthy Participants. Radiol Cardiothorac Imaging 2020; 2:e190033. [PMID: 32734274 DOI: 10.1148/ryct.2020190033] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2019] [Revised: 11/04/2019] [Accepted: 12/23/2019] [Indexed: 11/11/2022]
Abstract
Purpose To explore the feasibility of using four-dimensional (4D) flow MRI to quantify blood flow and kinetic energy (KE) in the heart during strenuous exercise. Materials and Methods For this prospective study, cardiac 4D flow MRI was performed in 11 healthy young adult participants (eight men, three women; mean age, 26 years ± 1 [standard deviation]) at rest and during exercise with an MRI-compatible exercise stepper between March 2016 and July 2017. Flow was measured in the ascending aorta (AAo) and main pulmonary artery (MPA). KE was quantified in the left and right ventricle. Significant changes in flow and KE during exercise were identified by using t tests. Repeatability was assessed with inter- and intraobserver comparisons and an analysis of internal flow consistency. Results Nine participants successfully completed both rest and exercise imaging. Internal flow consistency analysis in systemic and pulmonary circulation showed average relative differences of 10% at rest and 16% during exercise. For flow measurements in the AAo and MPA, relative differences between observers never exceeded 6% in any vessel and showed excellent correlation, even during exercise. Relative differences were increased for KE, typically on the order of 30%, with poor interobserver correlation between measurements. Conclusion Four-dimensional flow MRI can quantify increases in flow in the AAo and MPA during strenuous exercise and is highly repeatable. KE had reduced repeatability because of suboptimal segmentation methods and requires further development before clinical implementation. Supplemental material is available for this article. © RSNA, 2020See also the commentary by Markl and Lee in this issue.
Collapse
Affiliation(s)
- Jacob A Macdonald
- Departments of Medical Physics (J.A.M., P.A.C., O.W.), Pediatrics (A.G.B., G.P.B., K.N.G., M.W.E.), Medicine (K.N.G.), Biomedical Engineering (M.W.E., O.W.), and Radiology (C.J.F., O.W.), University of Wisconsin, 1111 Highland Ave, Room 1005, Madison, WI 53705
| | - Arij G Beshish
- Departments of Medical Physics (J.A.M., P.A.C., O.W.), Pediatrics (A.G.B., G.P.B., K.N.G., M.W.E.), Medicine (K.N.G.), Biomedical Engineering (M.W.E., O.W.), and Radiology (C.J.F., O.W.), University of Wisconsin, 1111 Highland Ave, Room 1005, Madison, WI 53705
| | - Philip A Corrado
- Departments of Medical Physics (J.A.M., P.A.C., O.W.), Pediatrics (A.G.B., G.P.B., K.N.G., M.W.E.), Medicine (K.N.G.), Biomedical Engineering (M.W.E., O.W.), and Radiology (C.J.F., O.W.), University of Wisconsin, 1111 Highland Ave, Room 1005, Madison, WI 53705
| | - Gregory P Barton
- Departments of Medical Physics (J.A.M., P.A.C., O.W.), Pediatrics (A.G.B., G.P.B., K.N.G., M.W.E.), Medicine (K.N.G.), Biomedical Engineering (M.W.E., O.W.), and Radiology (C.J.F., O.W.), University of Wisconsin, 1111 Highland Ave, Room 1005, Madison, WI 53705
| | - Kara N Goss
- Departments of Medical Physics (J.A.M., P.A.C., O.W.), Pediatrics (A.G.B., G.P.B., K.N.G., M.W.E.), Medicine (K.N.G.), Biomedical Engineering (M.W.E., O.W.), and Radiology (C.J.F., O.W.), University of Wisconsin, 1111 Highland Ave, Room 1005, Madison, WI 53705
| | - Marlowe W Eldridge
- Departments of Medical Physics (J.A.M., P.A.C., O.W.), Pediatrics (A.G.B., G.P.B., K.N.G., M.W.E.), Medicine (K.N.G.), Biomedical Engineering (M.W.E., O.W.), and Radiology (C.J.F., O.W.), University of Wisconsin, 1111 Highland Ave, Room 1005, Madison, WI 53705
| | - Christopher J François
- Departments of Medical Physics (J.A.M., P.A.C., O.W.), Pediatrics (A.G.B., G.P.B., K.N.G., M.W.E.), Medicine (K.N.G.), Biomedical Engineering (M.W.E., O.W.), and Radiology (C.J.F., O.W.), University of Wisconsin, 1111 Highland Ave, Room 1005, Madison, WI 53705
| | - Oliver Wieben
- Departments of Medical Physics (J.A.M., P.A.C., O.W.), Pediatrics (A.G.B., G.P.B., K.N.G., M.W.E.), Medicine (K.N.G.), Biomedical Engineering (M.W.E., O.W.), and Radiology (C.J.F., O.W.), University of Wisconsin, 1111 Highland Ave, Room 1005, Madison, WI 53705
| |
Collapse
|
10
|
Corrado PA, Macdonald JA, François CJ, Aggarwal NR, Weinsaft JW, Wieben O. Reduced regional flow in the left ventricle after anterior acute myocardial infarction: a case control study using 4D flow MRI. BMC Med Imaging 2019; 19:101. [PMID: 31888531 PMCID: PMC6937788 DOI: 10.1186/s12880-019-0404-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2019] [Accepted: 12/18/2019] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND Acute myocardial infarction (AMI) alters left ventricular (LV) hemodynamics, resulting in decreased global LV ejection fraction and global LV kinetic energy. We hypothesize that anterior AMI effects localized alterations in LV flow and developed a regional approach to analyze these local changes with 4D flow MRI. METHODS 4D flow cardiac magnetic resonance (CMR) data was compared between 12 anterior AMI patients (11 males; 66 ± 12yo; prospectively acquired in 2016-2017) and 19 healthy volunteers (10 males; 40 ± 16yo; retrospective from 2010 to 2011 study). The LV cavity was contoured on short axis cine steady-state free procession CMR and partitioned into three regions: base, mid-ventricle, and apex. 4D flow data was registered to the short axis segmentation. Peak systolic and diastolic through-plane flows were compared region-by-region between groups using linear models of flow with age, sex, and heart rate as covariates. RESULTS Peak systolic flow was reduced in anterior AMI subjects compared to controls in the LV mid-ventricle (fitted reduction = 3.9 L/min; P = 0.01) and apex (fitted reduction = 1.4 L/min; P = 0.02). Peak diastolic flow was also lower in anterior AMI subjects compared to controls in the apex (fitted reduction = 2.4 L/min; P = 0.01). CONCLUSIONS A regional method to analyze 4D LV flow data was applied in anterior AMI patients and controls. Anterior AMI patients had reduced regional flow relative to controls.
Collapse
Affiliation(s)
- Philip A. Corrado
- Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Ave, Madison, WI 53705 USA
| | - Jacob A. Macdonald
- Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Ave, Madison, WI 53705 USA
| | - Christopher J. François
- Department of Radiology, University of Wisconsin-Madison, 600 Highland Ave, Madison, WI 53792 USA
| | - Niti R. Aggarwal
- Department of Medicine, University of Wisconsin-Madison, 600 Highland Ave, Madison, WI 53792 USA
| | - Jonathan W. Weinsaft
- Departments of Medicine and Radiology, Weill Cornell Medical College, 520 East 70th Street, Starr Pavilion, 4th Floor, New York, NY 10021 USA
| | - Oliver Wieben
- Departments of Medical Physics and Radiology, University of Wisconsin-Madison, 1111 Highland Ave, Madison, WI 53705 USA
| |
Collapse
|