Kobayashi N. Optimization of flip angle and radiofrequency pulse phase to maximize steady-state magnetization in three-dimensional missing pulse steady-state free precession. NMR IN BIOMEDICINE 2024; 37:e5112. [PMID: 38299770 PMCID: PMC11078623 DOI: 10.1002/nbm.5112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 12/07/2023] [Accepted: 01/09/2024] [Indexed: 02/02/2024]
Abstract
Missing pulse (MP) steady-state free precession (SSFP) is a magnetic resonance imaging (MRI) pulse sequence that is highly tolerant to the magnetic field inhomogeneity. In this study, optimal flip angle and radiofrequency (RF) phase scheduling in three-dimensional (3D) MP-SSFP is introduced to maximize the steady-state magnetization while keeping broadband excitation to cover widely distributed frequencies generated by inhomogeneous magnetic fields. Numerical optimization based on extended phase graph (EPG) simulation was performed to maximize the MP-SSFP steady-state magnetization. To limit the specific absorption rate (SAR) associated with the broadband excitation in 3D MP-SSFP, SAR constraint was introduced in the numerical optimization. Optimized flip angle and RF phase settings were experimentally tested by introducing a linear inhomogeneous magnetic field in a range of 10-20 mT/m and using a phantom with known T1/T2 relaxation and diffusion parameters at 3 T. The experimental results were validated through comparisons with EPG simulation. Image contrasts and molecular diffusion effects were investigated in in vivo human brain imaging with 3D MP-SSFP with the optimal flip angle and RF phase settings. In the phantom measurements, the optimal flip angle and RF phase settings improved the MP-SSFP steady-state magnetization/signal-to-noise ratio by up to 41% under the fixed SAR conditions, which matched well with EPG simulation results. In vivo brain imaging with the optimal RF pulse settings provided T2-like image contrasts. Diffusion effects were relatively minor with the linear inhomogeneous field of 10-20 mT/m for white and gray matter, but cerebrospinal fluid showed conspicuous signal intensity attenuation as the linear inhomogeneous field increased. Numerical optimization achieved significant improvement in the steady-state magnetization in MP-SSFP compared with the RF pulse settings used in previous studies. The proposed flip angle and RF phase optimization is promising to improve 3D MP-SSFP image quality for MRI in inhomogeneous magnetic fields.
Collapse
Affiliation(s)
- Naoharu Kobayashi
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| |
Collapse
|
2
|
Theilenberg S, Shang Y, Ghazouani J, Kumaragamage C, Nixon TW, McIntyre S, Vaughan JT, Parkinson B, Garwood M, de Graaf RA, Juchem C. Design and realization of a multi-coil array for B 0 field control in a compact 1.5T head-only MRI scanner. Magn Reson Med 2023; 90:1228-1241. [PMID: 37145035 PMCID: PMC10330274 DOI: 10.1002/mrm.29692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2022] [Revised: 03/27/2023] [Accepted: 04/14/2023] [Indexed: 05/06/2023]
Abstract
PURPOSE To design and implement a multi-coil (MC) array for B0 field generation for image encoding and simultaneous advanced shimming in a novel 1.5T head-only MRI scanner. METHODS A 31-channel MC array was designed following the unique constraints of this scanner design: The vertically oriented magnet is very short, stopping shortly above the shoulders of a sitting subject, and includes a window for the subject to see through. Key characteristics of the MC hardware, the B0 field generation capabilities, and thermal behavior, were optimized in simulations prior to its construction. The unit was characterized via bench testing. B0 field generation capabilities were validated on a human 4T MR scanner by analysis of experimental B0 fields and by comparing images for several MRI sequences acquired with the MC array to those acquired with the system's linear gradients. RESULTS The MC system was designed to produce a multitude of linear and nonlinear magnetic fields including linear gradients of up to 10 kHz/cm (23.5 mT/m) with MC currents of 5 A per channel. With water cooling it can be driven with a duty cycle of up to 74% and ramp times of 500 μs. MR imaging experiments encoded with the developed multi-coil hardware were largely artifact-free; residual imperfections were predictable, and correctable. CONCLUSION The presented compact multi-coil array is capable of generating image encoding fields with amplitudes and quality comparable to clinical systems at very high duty cycles, while additionally enabling high-order B0 shimming capabilities and the potential for nonlinear encoding fields.
Collapse
Affiliation(s)
- Sebastian Theilenberg
- Department of Biomedical Engineering, Columbia University, New York, NY, United States
| | - Yun Shang
- Department of Biomedical Engineering, Columbia University, New York, NY, United States
| | - Jalal Ghazouani
- Department of Biomedical Engineering, Columbia University, New York, NY, United States
| | - Chathura Kumaragamage
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, United States
| | - Terence W. Nixon
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, United States
| | - Scott McIntyre
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, United States
| | - J. Thomas Vaughan
- Department of Biomedical Engineering, Columbia University, New York, NY, United States
- Department of Radiology, Columbia University Medical Center, New York, NY, United States
| | - Ben Parkinson
- Robinson Research Institute, Victoria University of Wellington, Wellington, New Zealand
| | - Mike Garwood
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, United States
| | - Robin A. de Graaf
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, United States
| | - Christoph Juchem
- Department of Biomedical Engineering, Columbia University, New York, NY, United States
- Department of Radiology, Columbia University Medical Center, New York, NY, United States
| |
Collapse
|
3
|
Chen H, Dai K, Bao J, Zhong S, Hu C, Liu Y, Zhang Z. Pseudo multishot echo-planar imaging for geometric distortion improvement. NMR IN BIOMEDICINE 2023; 36:e4885. [PMID: 36454107 DOI: 10.1002/nbm.4885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 11/21/2022] [Accepted: 11/24/2022] [Indexed: 06/17/2023]
Abstract
Conventional echo-planar imaging (EPI) uses a radiofrequency pulse for excitation and a prolonged echo train to sample k space, while off-resonance and T2 * decay effects caused by magnetic susceptibility variation accumulate within each echo, leading to geometric distortion. Multishot EPI methods, which divide k space into segments, can shorten the effective echo spacing and reduce the distortion on EPI images. But multiple shots cost longer scan time and render susceptibility to motion. In this study, we propose a new "multishot" EPI method termed pseudo multishot EPI (pmsEPI), in which phase-encoding lines are segmented as in multishot EPI but are collected within a single shot. With the magnetization divided into different pathways via interleaved excitation instead of refocusing in a single long echo train, the total phase error accumulation is reduced in each segmented acquisition, thereby improving distortion of the resultant EPI image. The performance of the pmsEPI method is demonstrated by phantom and in vivo brain experiments on a 3-T scanner. The experimental results show that the distortion displacements of pmsEPI acquisition compared with conventional EPI decrease by 50% with two pseudo shots and 66% with three pseudo shots, validating the ability of the method to obtain images with reduced distortion in a single shot, although magnetization splitting may induce more than 40% SNR loss and minor artifacts. Specifically, the ability of pmsEPI in diffusion-weighted imaging with different trajectory options is highlighted, and the flexibility is demonstrated in a single-shot blip up and down acquisition.
Collapse
Affiliation(s)
- Hao Chen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China
| | - Ke Dai
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Jianfeng Bao
- Functional Magnetic Resonance and Molecular Imaging Key Laboratory of Henan Province, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Sijie Zhong
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Chenxi Hu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Yiling Liu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Zhiyong Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
4
|
Wei L, Yu Y, Wang D, Yao S, Li N, Weng J, Zhang S, Liang J, Ma H, Yang J, Zhang Z. Research Progress on Magneto-Refractive Magnetic Field Fiber Sensors. SENSORS (BASEL, SWITZERLAND) 2023; 23:3391. [PMID: 37050450 PMCID: PMC10098542 DOI: 10.3390/s23073391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/05/2023] [Revised: 03/14/2023] [Accepted: 03/18/2023] [Indexed: 06/19/2023]
Abstract
The magnetic field is a vital physical quantity in nature that is closely related to human production life. Magnetic field sensors (namely magnetometers) have significant application value in scientific research, engineering applications, industrial productions, and so forth. Accompanied by the continuous development of magnetic materials and fiber-sensing technology, fiber sensors based on the Magneto-Refractive Effect (MRE) not only take advantage in compact structure, superior performance, and strong environmental adaptability but also further meet the requirement of the quasi-distributed/distributed magnetic field sensing; they manifest potential and great application value in space detection, marine environmental monitoring, etc. Consequently, the present and prevalent Magneto-Refractive Magnetic Field Fiber Sensors (MR-MFSs) are briefly summarized by this paper, proceeding from the perspective of physicochemical properties; design methods, basic performance and properties are introduced systematically as well. Furthermore, this paper also summarizes key fabrication techniques and future development trends of MR-MFSs, expecting to provide ideas and technical references for staff engaging in relevant research.
Collapse
Affiliation(s)
- Linyi Wei
- Key Laboratory of Disaster Prevention and Structural Safety of Ministry of Education, School of Computer, Electronics and Information, Guangxi University, Nanning 530004, China; (L.W.)
- Guangxi Key Laboratory of Disaster Prevention and Engineering Safety, Guangxi University, Nanning 530004, China
- Guangxi Key Laboratory of Multimedia Communications and Network Technology, School of Computer, Electronics and Information, Guangxi University, Nanning 530004, China
- College of Sciences, National University of Defense Technology, Changsha 410073, China; (Y.Y.); (D.W.); (J.Y.)
- College of Advanced Interdisciplinary Studies, National University of Defense Technology, Changsha 410073, China
| | - Yang Yu
- College of Sciences, National University of Defense Technology, Changsha 410073, China; (Y.Y.); (D.W.); (J.Y.)
- College of Advanced Interdisciplinary Studies, National University of Defense Technology, Changsha 410073, China
| | - Dongying Wang
- College of Sciences, National University of Defense Technology, Changsha 410073, China; (Y.Y.); (D.W.); (J.Y.)
- College of Advanced Interdisciplinary Studies, National University of Defense Technology, Changsha 410073, China
- Joint Laboratory for Extreme Conditions Matter Properties, Southwest University of Science and Technology, Mianyang 621010, China
| | - Siyu Yao
- Key Laboratory of Disaster Prevention and Structural Safety of Ministry of Education, School of Computer, Electronics and Information, Guangxi University, Nanning 530004, China; (L.W.)
- Guangxi Key Laboratory of Disaster Prevention and Engineering Safety, Guangxi University, Nanning 530004, China
- Guangxi Key Laboratory of Multimedia Communications and Network Technology, School of Computer, Electronics and Information, Guangxi University, Nanning 530004, China
- College of Sciences, National University of Defense Technology, Changsha 410073, China; (Y.Y.); (D.W.); (J.Y.)
- College of Advanced Interdisciplinary Studies, National University of Defense Technology, Changsha 410073, China
| | - Ning Li
- Key Laboratory of Disaster Prevention and Structural Safety of Ministry of Education, School of Computer, Electronics and Information, Guangxi University, Nanning 530004, China; (L.W.)
- Guangxi Key Laboratory of Disaster Prevention and Engineering Safety, Guangxi University, Nanning 530004, China
- Guangxi Key Laboratory of Multimedia Communications and Network Technology, School of Computer, Electronics and Information, Guangxi University, Nanning 530004, China
- College of Sciences, National University of Defense Technology, Changsha 410073, China; (Y.Y.); (D.W.); (J.Y.)
- College of Advanced Interdisciplinary Studies, National University of Defense Technology, Changsha 410073, China
| | - Junjie Weng
- Key Laboratory of Disaster Prevention and Structural Safety of Ministry of Education, School of Computer, Electronics and Information, Guangxi University, Nanning 530004, China; (L.W.)
- Guangxi Key Laboratory of Disaster Prevention and Engineering Safety, Guangxi University, Nanning 530004, China
- Guangxi Key Laboratory of Multimedia Communications and Network Technology, School of Computer, Electronics and Information, Guangxi University, Nanning 530004, China
- College of Sciences, National University of Defense Technology, Changsha 410073, China; (Y.Y.); (D.W.); (J.Y.)
- College of Advanced Interdisciplinary Studies, National University of Defense Technology, Changsha 410073, China
| | - Shumao Zhang
- Key Laboratory of Disaster Prevention and Structural Safety of Ministry of Education, School of Computer, Electronics and Information, Guangxi University, Nanning 530004, China; (L.W.)
- Guangxi Key Laboratory of Disaster Prevention and Engineering Safety, Guangxi University, Nanning 530004, China
- Guangxi Key Laboratory of Multimedia Communications and Network Technology, School of Computer, Electronics and Information, Guangxi University, Nanning 530004, China
- College of Sciences, National University of Defense Technology, Changsha 410073, China; (Y.Y.); (D.W.); (J.Y.)
- College of Advanced Interdisciplinary Studies, National University of Defense Technology, Changsha 410073, China
| | - Jianqiao Liang
- Key Laboratory of Disaster Prevention and Structural Safety of Ministry of Education, School of Computer, Electronics and Information, Guangxi University, Nanning 530004, China; (L.W.)
- Guangxi Key Laboratory of Disaster Prevention and Engineering Safety, Guangxi University, Nanning 530004, China
- Guangxi Key Laboratory of Multimedia Communications and Network Technology, School of Computer, Electronics and Information, Guangxi University, Nanning 530004, China
- College of Sciences, National University of Defense Technology, Changsha 410073, China; (Y.Y.); (D.W.); (J.Y.)
- College of Advanced Interdisciplinary Studies, National University of Defense Technology, Changsha 410073, China
| | - Hansi Ma
- College of Sciences, National University of Defense Technology, Changsha 410073, China; (Y.Y.); (D.W.); (J.Y.)
| | - Junbo Yang
- College of Sciences, National University of Defense Technology, Changsha 410073, China; (Y.Y.); (D.W.); (J.Y.)
| | - Zhenrong Zhang
- Key Laboratory of Disaster Prevention and Structural Safety of Ministry of Education, School of Computer, Electronics and Information, Guangxi University, Nanning 530004, China; (L.W.)
- Guangxi Key Laboratory of Disaster Prevention and Engineering Safety, Guangxi University, Nanning 530004, China
- Guangxi Key Laboratory of Multimedia Communications and Network Technology, School of Computer, Electronics and Information, Guangxi University, Nanning 530004, China
| |
Collapse
|
5
|
Seginer A, Schmidt R. Phase-based fast 3D high-resolution quantitative T 2 MRI in 7 T human brain imaging. Sci Rep 2022; 12:14088. [PMID: 35982143 PMCID: PMC9388657 DOI: 10.1038/s41598-022-17607-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Accepted: 07/28/2022] [Indexed: 12/04/2022] Open
Abstract
Magnetic resonance imaging (MRI) is a powerful and versatile technique that offers a range of physiological, diagnostic, structural, and functional measurements. One of the most widely used basic contrasts in MRI diagnostics is transverse relaxation time (T2)-weighted imaging, but it provides only qualitative information. Realizing quantitative high-resolution T2 mapping is imperative for the development of personalized medicine, as it can enable the characterization of diseases progression. While ultra-high-field (≥ 7 T) MRI offers the means to gain new insights by increasing the spatial resolution, implementing fast quantitative T2 mapping cannot be achieved without overcoming the increased power deposition and radio frequency (RF) field inhomogeneity at ultra-high-fields. A recent study has demonstrated a new phase-based T2 mapping approach based on fast steady-state acquisitions. We extend this new approach to ultra-high field MRI, achieving quantitative high-resolution 3D T2 mapping at 7 T while addressing RF field inhomogeneity and utilizing low flip angle pulses; overcoming two main ultra-high field challenges. The method is based on controlling the coherent transverse magnetization in a steady-state gradient echo acquisition; achieved by utilizing low flip angles, a specific phase increment for the RF pulses, and short repetition times. This approach simultaneously extracts both T2 and RF field maps from the phase of the signal. Prior to in vivo experiments, the method was assessed using a 3D head-shaped phantom that was designed to model the RF field distribution in the brain. Our approach delivers fast 3D whole brain images with submillimeter resolution without requiring special hardware, such as multi-channel transmit coil, thus promoting high usability of the ultra-high field MRI in clinical practice.
Collapse
Affiliation(s)
| | - Rita Schmidt
- Department of Brain Sciences, Weizmann Institute of Science, Rehovot, Israel. .,The Azrieli National Institute for Human Brain Imaging and Research, Weizmann Institute of Science, Rehovot, Israel.
| |
Collapse
|
6
|
Curcuru AN, Kim T, Yang D, Gach HM. Real-time B 0 compensation during gantry rotation in a 0.35 T MRI-Linac. Med Phys 2022; 49:6451-6460. [PMID: 35906957 DOI: 10.1002/mp.15892] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 07/06/2022] [Accepted: 07/24/2022] [Indexed: 11/08/2022] Open
Abstract
BACKGROUND Rotation of the ferromagnetic gantry of a low magnetic field MRI-Linac was previously demonstrated to cause large center frequency offsets of ±400 Hz. The B0 off-resonances cause image artifacts and imaging isocenter shifts that would preclude MRI-guided arc therapy. PURPOSE The purpose of this study was to measure and compensate for center frequency offsets in real-time during gantry rotation on a 0.35 T MRI-Linac using a free induction decay (FID) navigator. METHODS A nonselective FID navigator was added before each 2D balanced steady-state free precession (bSSFP) cine image acquisition on a 0.35 T MRI-Linac. Images were acquired at 7.3 frames per second. Phase data from the initial FID navigator (while the gantry was stationary) was used as a reference. The phase data from each subsequent FID navigator was used to calculate the real-time B0 off-resonance. The transmitter/receiver phase and the phase accrual over the adjacent image acquisition were adjusted to correct for the center frequency offset. Measurements were performed using a MRI-Linac dynamic phantom prior to and while the gantry rotated clockwise and counterclockwise. Image quality and signal-to-noise ratio were compared between uncorrected and B0 corrected MRIs using a reference image acquired while the gantry was stationary. Four targets in the phantom were manually contoured on the first image frame and an active contouring algorithm was used retrospectively on each subsequent frame to assess image variations and calculate Dice coefficients. Additionally, three healthy volunteers were imaged using the same pulse sequences with and without real-time B0 compensation during gantry rotation. Normalized root mean square errors (nRMSEs) were calculated for the phantom and in vivo to assess the efficacy of the B0 compensation on image quality. The measured center frequency offsets from the volunteer and MRI dynamic phantom navigator data were also compared. The sinusoidal behavior of the center frequency offsets was modeled based on the gantry layout and long time constant eddy currents resulting from gantry rotation. RESULTS The duration of the FID navigator and processing was 4.5 ms. The FID navigator resulted in a ≤11% drop in signal-to-noise ratio (SNR) in the phantom and in vivo (liver). Dice coefficients from the MR-IGRT phantom contour measurements remained above 0.8 with B0 compensation. Without B0 compensation, the Dice coefficients dropped below 0.8 for up to 21% of the time depending on the contour. Real-time B0 compensation resulted in mean reductions in nRMSE of 51% and 16% for the MR-IGRT phantom and in vivo, respectively. Peak-to-peak center frequency offsets ranged from 757 to 773 Hz in the phantom and 670 to 871 Hz in vivo. CONCLUSION Dynamic real-time B0 compensation significantly improved image quality and reduced artifacts during gantry rotation in the phantom and in vivo. However, the FID navigator resulted in a small drop in the imaging duty cycle and SNR. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Austen N Curcuru
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, Missouri, 63110, USA
| | - Taeho Kim
- Department of Radiation Oncology, Washington University in St. Louis, St. Louis, Missouri, 63110, USA
| | - Deshan Yang
- Departments of Radiation Oncology and Biomedical Engineering, Washington University in St. Louis, St. Louis, Missouri, 63110, USA
| | - H Michael Gach
- Departments of Radiation Oncology, Radiology, and Biomedical Engineering, Washington University in St. Louis, St. Louis, Missouri, 63110, USA
| |
Collapse
|
7
|
Mullen M, Garwood M. Dual polarity encoded MRI using high bandwidth radiofrequency pulses for robust imaging with large field inhomogeneity. Magn Reson Med 2021; 86:1271-1283. [PMID: 33780035 DOI: 10.1002/mrm.28771] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Revised: 02/02/2021] [Accepted: 02/22/2021] [Indexed: 11/09/2022]
Abstract
PURPOSE The ability to use dual polarity encoded MRI with the missing pulse steady-state free precession (MP-SSFP) sequence is demonstrated to perform robust MRI with low radiofrequency (RF) amplitude, where the field is distorted by embedding metallic screws in an agar phantom. Image-based estimation of the 3D ΔB0 map and image distortion correction is shown to require ~1 minute to perform. THEORY AND METHODS Dual polarity encoded MP-SSFP was implemented at 1.5T and used to image agar phantoms with one stainless steel and one titanium screw embedded inside. A multispectral fast spin-echo acquisition was performed for comparison. Self-consistent ΔB0 estimation is performed iteratively using a 3D B-spline basis, which is compared to the ΔB0 estimate generated by the multispectral sequence. RESULTS Dual polarity encoded MP-SSFP yields image quality similar to the multispectral sequence used with substantially less imaging time, provided the MP-SSFP experimental parameters are chosen well. The multispectral sequence appears to visualize modestly closer in proximity to the metallic screws used, despite the spectral bins covering the same bandwidth as the pulses used in MP-SSFP. However, MP-SSFP avoids ripple artifacts characteristic of the multispectral sequence. The ΔB0 estimate generated by MP-SSFP is qualitatively similar to that generated by the multispectral sequence but larger in magnitude. CONCLUSION Despite longer processing time compared to multispectral imaging, MP-SSFP yields similar image quality with significantly lower acquisition times in the absence of parallel imaging. The work herein demonstrates the ability to perform 3D ΔB0 estimation and image correction within a reasonable amount of time, ~1 minute.
Collapse
Affiliation(s)
- Michael Mullen
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Michael Garwood
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| |
Collapse
|
8
|
Mullen M, Garwood M. Contemporary approaches to high-field magnetic resonance imaging with large field inhomogeneity. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2020; 120-121:95-108. [PMID: 33198970 PMCID: PMC7672259 DOI: 10.1016/j.pnmrs.2020.07.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 07/16/2020] [Accepted: 07/18/2020] [Indexed: 06/11/2023]
Abstract
Despite its importance as a clinical imaging modality, magnetic resonance imaging remains inaccessible to most of the world's population due to its high cost and infrastructure requirements. Substantial effort is underway to develop portable, low-cost systems able to address MRI access inequality and to enable new uses of MRI such as bedside imaging. A key barrier to development of portable MRI systems is increased magnetic field inhomogeneity when using small polarizing magnets, which degrades image quality through distortions and signal dropout. Many approaches address field inhomogeneity by using a low polarizing field, approximately ten to hundreds of milli-Tesla. At low-field, even a large relative field inhomogeneity of several thousand parts-per-million (ppm) results in resonance frequency dispersion of only 1-2 kHz. Under these conditions, with necessarily wide pulse bandwidths, fast spin-echo sequences may be used at low field with negligible subject heating, and a broad range of other available imaging sequences can be implemented. However, high-field MRI, 1.5 T or greater, can provide substantially improved signal-to-noise ratio and image contrast, so that higher spatial resolution, clinical quality images may be acquired in significantly less time than is necessary at low-field. The challenge posed by small, high-field systems is that the relative field inhomogeneity, still thousands of ppm, becomes tens of kilohertz over the imaging volume. This article describes the physical consequences of field inhomogeneity on established gradient- and spin-echo MRI sequences, and suggests ways to reduce signal dropout and image distortion from field inhomogeneity. Finally, the practicality of currently available image contrasts is reviewed when imaging with a high magnetic field with large inhomogeneity.
Collapse
Affiliation(s)
- Michael Mullen
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, MN, USA.
| | - Michael Garwood
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, MN, USA.
| |
Collapse
|