Brackenier Y, Cordero-Grande L, McElroy S, Tomi-Tricot R, Barbaroux H, Bridgen P, Malik SJ, Hajnal JV. Sequence-agnostic motion-correction leveraging efficiently calibrated Pilot Tone signals. Magn Reson Med 2024. [PMID: 38860530 DOI: 10.1002/mrm.30161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 04/18/2024] [Accepted: 05/07/2024] [Indexed: 06/12/2024]
Abstract
PURPOSE This study leverages externally generated Pilot Tone (PT) signals to perform motion-corrected brain MRI for sequences with arbitrary k-space sampling and image contrast. THEORY AND METHODS PT signals are promising external motion sensors due to their cost-effectiveness, easy workflow, and consistent performance across contrasts and sampling patterns. However, they lack robust calibration pipelines. This work calibrates PT signal to rigid motion parameters acquired during short blocks (˜4 s) of motion calibration (MC) acquisitions, which are short enough to unobstructively fit between acquisitions. MC acquisitions leverage self-navigated trajectories that enable state-of-the-art motion estimation methods for efficient calibration. To capture the range of patient motion occurring throughout the examination, distributed motion calibration (DMC) uses data acquired from MC scans distributed across the entire examination. After calibration, PT is used to retrospectively motion-correct sequences with arbitrary k-space sampling and image contrast. Additionally, a data-driven calibration refinement is proposed to tailor calibration models to individual acquisitions. In vivo experiments involving 12 healthy volunteers tested the DMC protocol's ability to robustly correct subject motion. RESULTS The proposed calibration pipeline produces pose parameters consistent with reference values, even when distributing only six of these approximately 4-s MC blocks, resulting in a total acquisition time of 22 s. In vivo motion experiments reveal significant (p < 0.05 $$ p<0.05 $$ ) improved motion correction with increased signal to residual ratio for both MPRAGE and SPACE sequences with standard k-space acquisition, especially when motion is large. Additionally, results highlight the benefits of using a distributed calibration approach. CONCLUSIONS This study presents a framework for performing motion-corrected brain MRI in sequences with arbitrary k-space encoding and contrast, using externally generated PT signals. The DMC protocol is introduced, promoting observation of patient motion occurring throughout the examination and providing a calibration pipeline suitable for clinical deployment. The method's application is demonstrated in standard volumetric MPRAGE and SPACE sequences.
Collapse
Affiliation(s)
- Yannick Brackenier
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Lucilio Cordero-Grande
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Biomedical Image Technologies, ETSI Telecomunicación, Universidad Politécnica de Madrid and CIBER-BNN, ISCIII, Madrid, Spain
| | - Sarah McElroy
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- MR Research Collaborations, Siemens Healthcare Limited, Frimley, UK
| | - Raphael Tomi-Tricot
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- MR Research Collaborations, Siemens Healthcare Limited, Frimley, UK
| | - Hugo Barbaroux
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Philippa Bridgen
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Shaihan J Malik
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Joseph V Hajnal
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| |
Collapse
|
2
|
Brackenier Y, Wang N, Liao C, Cao X, Schauman S, Yurt M, Cordero-Grande L, Malik SJ, Kerr A, Hajnal JV, Setsompop K. Rapid and accurate navigators for motion and B 0 tracking using QUEEN: Quantitatively enhanced parameter estimation from navigators. Magn Reson Med 2024; 91:2028-2043. [PMID: 38173304 DOI: 10.1002/mrm.29976] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2023] [Revised: 11/28/2023] [Accepted: 11/29/2023] [Indexed: 01/05/2024]
Abstract
PURPOSE To develop a framework that jointly estimates rigid motion and polarizing magnetic field (B0 ) perturbations (δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ ) for brain MRI using a single navigator of a few milliseconds in duration, and to additionally allow for navigator acquisition at arbitrary timings within any type of sequence to obtain high-temporal resolution estimates. THEORY AND METHODS Methods exist that match navigator data to a low-resolution single-contrast image (scout) to estimate either motion orδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ . In this work, called QUEEN (QUantitatively Enhanced parameter Estimation from Navigators), we propose combined motion andδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ estimation from a fast, tailored trajectory with arbitrary-contrast navigator data. To this end, the concept of a quantitative scout (Q-Scout) acquisition is proposed from which contrast-matched scout data is predicted for each navigator. Finally, navigator trajectories, contrast-matched scout, andδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ are integrated into a motion-informed parallel-imaging framework. RESULTS Simulations and in vivo experiments show the need to modelδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ to obtain accurate motion parameters estimated in the presence of strongδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ . Simulations confirm that tailored navigator trajectories are needed to robustly estimate both motion andδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ . Furthermore, experiments show that a contrast-matched scout is needed for parameter estimation from multicontrast navigator data. A retrospective, in vivo reconstruction experiment shows improved image quality when using the proposed Q-Scout and QUEEN estimation. CONCLUSIONS We developed a framework to jointly estimate rigid motion parameters andδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ from navigators. Combing a contrast-matched scout with the proposed trajectory allows for navigator deployment in almost any sequence and/or timing, which allows for higher temporal-resolution motion andδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ estimates.
Collapse
Affiliation(s)
| | - Nan Wang
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Congyu Liao
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Xiaozhi Cao
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Sophie Schauman
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Mahmut Yurt
- Department of Radiology, Stanford University, Stanford, California, USA
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - Lucilio Cordero-Grande
- Biomedical Image Technologies, ETSI Telecomunicación, Universidad Politécnica de Madrid and CIBER-BNN, Madrid, Spain
| | - Shaihan J Malik
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Adam Kerr
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
- Cognitive and Neurobiological Imaging, Stanford University, Stanford, California, USA
| | - Joseph V Hajnal
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Kawin Setsompop
- Department of Radiology, Stanford University, Stanford, California, USA
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
| |
Collapse
|
3
|
Hewlett M, Oran O, Liu J, Drangova M. Prospective motion correction for brain MRI using spherical navigators. Magn Reson Med 2024; 91:1528-1540. [PMID: 38174443 DOI: 10.1002/mrm.29961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 10/24/2023] [Accepted: 11/20/2023] [Indexed: 01/05/2024]
Abstract
PURPOSE To demonstrate for the first time the feasibility of performing prospective motion correction using spherical navigators (SNAVs). METHODS SNAVs were interleaved in a 3D FLASH sequence with an additional short baseline scan (6.8 s) for fast rotation estimation. Assessment of SNAV-based prospective motion correction was performed in six volunteers. Participant motion was guided using randomly generated stepwise prompts as well as prompts derived from real motion cases. Experiments were performed on a 3 T MRI scanner using a 32-channel head coil. RESULTS When optimized for real-time application, SNAV-based motion estimates were computed in 25.8 ± 1.3 ms. Phantom-based quantification of rotation and translation accuracy indicated mean absolute errors of 0.10 ± 0.09° and 0.25 ± 0.14 mm, respectively. Implementing SNAV-based motion estimates for prospective motion correction led to a clear improvement in image quality with minimal increase in scan time (<5%). CONCLUSION Optimization of SNAV processing for real-time application enables prospective motion correction with low latency and minimal scan time requirements.
Collapse
Affiliation(s)
- Miriam Hewlett
- Robarts Research Institute, The University of Western Ontario, London, Ontario, Canada
- Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada
| | - Omer Oran
- Siemens Healthcare Limited, Oakville, Ontario, Canada
| | - Junmin Liu
- Robarts Research Institute, The University of Western Ontario, London, Ontario, Canada
| | - Maria Drangova
- Robarts Research Institute, The University of Western Ontario, London, Ontario, Canada
- Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada
| |
Collapse
|