1
|
Jeong HJ, Seol A, Lee S, Lim H, Lee M, Oh SJ. Portable Ultrasound Bladder Volume Measurement Over Entire Volume Range Using a Deep Learning Artificial Intelligence Model in a Selected Cohort: A Proof of Principle Study. Neurourol Urodyn 2025. [PMID: 40384598 DOI: 10.1002/nau.70057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2025] [Revised: 03/19/2025] [Accepted: 04/06/2025] [Indexed: 05/20/2025]
Abstract
OBJECTIVE We aimed to prospectively investigate whether bladder volume measured using deep learning artificial intelligence (AI) algorithms (AI-BV) is more accurate than that measured using conventional methods (C-BV) if using a portable ultrasound bladder scanner (PUBS). PATIENTS AND METHODS Patients who underwent filling cystometry because of lower urinary tract symptoms between January 2021 and July 2022 were enrolled. Every time the bladder was filled serially with normal saline from 0 mL to maximum cystometric capacity in 50 mL increments, C-BV was measured using PUBS. Ultrasound images obtained during this process were manually annotated to define the bladder contour, which was used to build a deep learning AI model. The true bladder volume (T-BV) for each bladder volume range was compared with C-BV and AI-BV for analysis. RESULTS We enrolled 250 patients (213 men and 37 women), and a deep learning AI model was established using 1912 bladder images. There was a significant difference between C-BV (205.5 ± 170.8 mL) and T-BV (190.5 ± 165.7 mL) (p = 0.001), but no significant difference between AI-BV (197.0 ± 161.1 mL) and T-BV (190.5 ± 165.7 mL) (p = 0.081). In bladder volume ranges of 101-150, 151-200, and 201-300 mL, there were significant differences in the percentage of volume differences between [C-BV and T-BV] and [AI-BV and T-BV] (p < 0.05), but no significant difference if converted to absolute values (p > 0.05). C-BV (R2 = 0.91, p < 0.001) and AI-BV (R2 = 0.90, p < 0.001) were highly correlated with T-BV. The mean difference between AI-BV and T-BV (6.5 ± 50.4) was significantly smaller than that between C-BV and T-BV (15.0 ± 50.9) (p = 0.001). CONCLUSION Following image pre-processing, deep learning AI-BV more accurately estimated true BV than conventional methods in this selected cohort on internal validation. Determination of the clinical relevance of these findings and performance in external cohorts requires further study. TRIAL REGISTRATION The clinical trial was conducted using an approved product for its approved indication, so approval from the Ministry of Food and Drug Safety (MFDS) was not required. Therefore, there is no clinical trial registration number.
Collapse
Affiliation(s)
- Hyun Ju Jeong
- Department of Medical Device Development, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Aeran Seol
- Department of Obstetrics and Gynecology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| | - Seungjun Lee
- Department of Obstetrics and Gynecology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea
- Department of Obstetrics and Gynecology, Dankook University College of Medicine, Cheonan, Republic of Korea
| | - Hyunji Lim
- Department of Obstetrics and Gynecology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| | - Maria Lee
- Department of Obstetrics and Gynecology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| | - Seung-June Oh
- Department of Medical Device Development, Seoul National University College of Medicine, Seoul, Republic of Korea
- Department of Urology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| |
Collapse
|
2
|
Lebdai S, Doizi S, Kassab D, Gas J, Pradere B, Robert G. Pre-therapeutical assessment of lower urinary tract symptoms in adult men: Systematic review and clinical practice guidelines. THE FRENCH JOURNAL OF UROLOGY 2025; 35:102846. [PMID: 39647566 DOI: 10.1016/j.fjurol.2024.102846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2024] [Accepted: 12/03/2024] [Indexed: 12/10/2024]
Abstract
INTRODUCTION The aim was to propose initial and pre-therapeutical assessment of lower urinary tract symptoms in adult men through a systematic review and clinical practice guidelines. METHODS These guidelines were based on a systematic review performed between January 2011 and November 2021 in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria. The protocol was registered in the International Prospective Register of Systematic Reviews database (CRD42022336418). The recommendations and the methodology of elaboration were prospectively validated by the French Health Authority (Haute Autorité de santé [HAS]). RESULTS In total, 1662 publications were screened for eligibility and 311 met the inclusion criteria, 167 studies were retained among them 17 guidelines from French, European or International institutions. Perform on initial evaluation: identification of cardiovascular risk factors, metabolic syndrome, current medication, urinary and sexual symptoms (by structured interview or validated self-questionnaires), physical examination (lumbar fossa, pelvis, prostate, genitalia), urinalysis (dipstick or microscopy), abdominal ultrasound of the urinary tract (kidneys, bladder, prostate), post-void residual urine measurement (by ultrasound or automated measurement; under physiological conditions). Micturition flowmetry is recommended (except for general practitioners). Update and complete initial assessment before medication, interventional or surgical treatment if too old or incomplete. Perform a preoperative assessment (bleeding risk, infectious risk, geriatric risk). Urodynamic assessment, endorectal ultrasound and cystoscopy should not be systematically performed (only if additional information is needed). Perform urodynamics and urethrocystoscopy in case of failed interventional or surgical treatment. Following the initial workup, it is recommended to refer the patient to a urologist in case of: macroscopic hematuria, recurrent urinary tract infection or persistent perineal and/or suprapubic pain, persistent microscopic hematuria or leukocyturia in absence of urinary tract infection, predominant storage-phase symptoms, abnormal examination of the genitals or suspected prostate cancer, urinary retention, urinary tract stones, ureterohydronephrosis or morphological abnormalities of the prostate or the urinary tract. CONCLUSION These guidelines aimed to define the recommended investigation for LUTS in adult men at diagnosis, before medical treatment and before surgical and interventional treatments, in order to better personalize management and avoid unnecessary and/or invasive examinations.
Collapse
Affiliation(s)
- Souhil Lebdai
- Urology Department, CHU d'Angers, 4, rue Larrey, 49933 Angers cedex, France.
| | | | - Diana Kassab
- Association Française d'Urologie, Paris, France.
| | - Jérôme Gas
- Urology Department, Uropole, Montauban, France.
| | - Benjamin Pradere
- Urology Department, UROSUD, Clinique La Croix du Sud, Quint-Fonsegrives, France.
| | | |
Collapse
|
3
|
Manfredini G, Anract J, Barry Delongchamps N. Post-void residual measurement: A comprehensive review of the clinical relevance and precision of bladder scanner devices. THE FRENCH JOURNAL OF UROLOGY 2025; 35:102870. [PMID: 39983905 DOI: 10.1016/j.fjurol.2025.102870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2024] [Revised: 02/07/2025] [Accepted: 02/14/2025] [Indexed: 02/23/2025]
Abstract
OBJECTIVE To evaluate the accuracy of bladder scanners in measuring bladder volume and to compare their precision. METHOD MEDLINE and Cochrane databases were searched from January 1, 1990 to December 30th, 2023. We selected studies assessing results of bladder volume measurement using bladder scanners, standard ultrasonography or bladder catheterization. RESULTS In total, 177 studies were screened, of which 22 were included in the final analysis. According to the literature, there is no clinically significant difference in the measurement of bladder volume using urethro-vesical catheterization, bladder scanner, or conventional ultrasound. Studies comparing different types of bladder scanners did not show any difference in accuracy. CONCLUSIONS Bladder scanners are precise tools to evaluate bladder volume in urological patients, applicable in daily practice. Knowledge of the patient's medical history is crucial to better interpret the measurement.
Collapse
Affiliation(s)
- Giulia Manfredini
- Urology Department, Cochin Hospital, Université Paris Cité, Paris, France
| | - Julien Anract
- Urology Department, Cochin Hospital, Université Paris Cité, Paris, France; Inserm U1151, Institut Necker-Enfants-maladies (INEM), Paris, France.
| | - Nicolas Barry Delongchamps
- Urology Department, Cochin Hospital, Université Paris Cité, Paris, France; Inserm U1151, Institut Necker-Enfants-maladies (INEM), Paris, France
| |
Collapse
|
4
|
Minagawa T. Recent developments in diagnostic ultrasound for lower urinary tract function. J Med Ultrason (2001) 2024:10.1007/s10396-024-01494-0. [PMID: 39327335 DOI: 10.1007/s10396-024-01494-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2024] [Accepted: 08/05/2024] [Indexed: 09/28/2024]
Abstract
Ultrasonography (US) is an essential tool in the clinical management of lower urinary tract dysfunction (LUTD), including lower urinary tract symptoms, overactive bladder, and benign prostatic hyperplasia, in which prostatic volume and post-void residual volume are routinely used to evaluate the pathophysiological characteristics of afflicted patients. US can also be employed to diagnose hydronephrosis and bladder calculus as complications of severe LUTD. Moreover, US is essential for identifying pathophysiological characteristics and surgical indications, predicting disease development and drug efficacy, and monitoring bladder function improvement by means of such parameters as bladder wall thickness, prostatic urethral length, intravesical prostatic protrusion, and prostatic urethral angulation/angle. Herein, I narratively review the recent advances in US approaches for the management of LUTD, especially in adult males.
Collapse
Affiliation(s)
- Tomonori Minagawa
- Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano, 390-8621, Japan.
| |
Collapse
|
5
|
Cho H, Song I, Jang J, Yoo Y. A Lightweight Deep Learning Network on a System-on-Chip for Wearable Ultrasound Bladder Volume Measurement Systems: Preliminary Study. Bioengineering (Basel) 2023; 10:bioengineering10050525. [PMID: 37237594 DOI: 10.3390/bioengineering10050525] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 04/17/2023] [Accepted: 04/25/2023] [Indexed: 05/28/2023] Open
Abstract
Bladder volume assessments are crucial for managing urinary disorders. Ultrasound imaging (US) is a preferred noninvasive, cost-effective imaging modality for bladder observation and volume measurements. However, the high operator dependency of US is a major challenge due to the difficulty in evaluating ultrasound images without professional expertise. To address this issue, image-based automatic bladder volume estimation methods have been introduced, but most conventional methods require high-complexity computing resources that are not available in point-of-care (POC) settings. Therefore, in this study, a deep learning-based bladder volume measurement system was developed for POC settings using a lightweight convolutional neural network (CNN)-based segmentation model, which was optimized on a low-resource system-on-chip (SoC) to detect and segment the bladder region in ultrasound images in real time. The proposed model achieved high accuracy and robustness and can be executed on the low-resource SoC at 7.93 frames per second, which is 13.44 times faster than the frame rate of a conventional network with negligible accuracy drawbacks (0.004 of the Dice coefficient). The feasibility of the developed lightweight deep learning network was demonstrated using tissue-mimicking phantoms.
Collapse
Affiliation(s)
- Hyunwoo Cho
- Department of Electronic Engineering, Sogang University, Seoul 04107, Republic of Korea
| | - Ilseob Song
- Medical Solutions Institute, Sogang University, Seoul 04107, Republic of Korea
- Edgecare Inc., TE1103, 35 Baekbeom-ro, Mapo-gu, Seoul 04107, Republic of Korea
| | - Jihun Jang
- Medical Solutions Institute, Sogang University, Seoul 04107, Republic of Korea
- Edgecare Inc., TE1103, 35 Baekbeom-ro, Mapo-gu, Seoul 04107, Republic of Korea
| | - Yangmo Yoo
- Department of Electronic Engineering, Sogang University, Seoul 04107, Republic of Korea
- Edgecare Inc., TE1103, 35 Baekbeom-ro, Mapo-gu, Seoul 04107, Republic of Korea
- Department of Biomedical Engineering, Sogang University, Seoul 04107, Republic of Korea
| |
Collapse
|
6
|
Can portable ultrasound bladder scanner be applied to young children less than three years old? J Pediatr Urol 2022; 18:344-349. [PMID: 35221250 DOI: 10.1016/j.jpurol.2022.02.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Revised: 01/21/2022] [Accepted: 02/02/2022] [Indexed: 11/21/2022]
Abstract
INTRODUCTION The bladder scanner (BS), a portable ultrasound device specialized in bladder volume measurement, has been developed and applied to clinical assessment of postvoid residual urine, which is a requisite in evaluating patients with voiding dysfunction. However, experiences in the application of the BS to the pediatric population remain limited despite commonly encountered reluctance to catheterization. This prospective observational study aimed to evaluate the correlation and accuracy of the newly developed pediatric module of the BS (BioCon-900) in measuring bladder volume in children 0-6 years old. MATERIALS AND METHODS This study included 29 patients scheduled to undergo preventive untethering for their spinal dysraphism. When they undergo cystometry for the confirmation of normal neurologic function, bladder volume was measured by BS when recorded volume infusion reached each quartile of the age-adjusted estimated bladder capacity (EBC). The difference (bias) between measured and infused volume was expressed as a percentage of EBC (%EBC). The correlation coefficient and the Bland-Altman plot were obtained to determine the discriminating power and accuracy, respectively. The acceptable limit was set as 30%EBC. RESULTS A strong correlation between the measured and infused volume (r = 0.95, P < 0.001) was found for the entire age range. This excellent correlation remained comparable between children less than three years and the older ones. Bladder volume tended to be overestimated, and the mean bias was 33 ± 22.3%EBC, and it became higher with increasing quartiles. The accuracy was acceptable in all ranges of measurement in the older group and first and second quartiles in the younger one. DISCUSSION We have first evaluated the potential use of BS in 0-3 years old children and compared the results with 4-6-year-old children in whom the accuracy of BS has been demonstrated. The strong point of our study was the inclusion of data spanning all quartiles of bladder volume. The use of infused volume as reference enabled us to assess the accuracy in a more precise way than the use of ultrasound. Despite the good discriminating power, the accuracy was not acceptable in higher quartiles in the younger group. If the trend of overestimation especially higher volume, could be understood prior to measurement, it would be helpful to assume the real val. CONCLUSIONS The children's module in BS showed excellent discriminating power and generally acceptable accuracy in more than four-year-old children. This may lose accuracy in higher quartiles among less than three years old children.
Collapse
|
7
|
Matsumoto M, Tamai N, Miura Y, Okawa Y, Yoshida M, Igawa Y, Nakagami G, Sanada H. Evaluation of a Point-of-Care Ultrasound Educational Program for Nurse Educators. J Contin Educ Nurs 2021; 52:375-381. [PMID: 34324378 DOI: 10.3928/00220124-20210714-07] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND The effectiveness of point-of-care ultrasound (POCUS) for nurses has been demonstrated; however, only a limited number of nurses have been trained to perform POCUS. This article reports on a POCUS train-the-trainer program for nurse educators that targets lower urinary track dysfunction. METHOD Nurse educators (n = 38) were invited to participate in a POCUS train-the-trainer program, which comprised an e-learning module and a hands-on seminar. Acquisition of knowledge and skills were assessed after the module and seminar, respectively. RESULTS Questions from the "Basic Knowledge of Ultrasonography" test were answered correctly at a rate of 93.0% (SD, 8.5%). Measured values of bladder urinary volume using ultrasonography were in close agreement with actual values. All of the participants indicated that the program covered the content necessary to use in practice. CONCLUSION The POCUS train-the-trainer program equips nurse educators with the knowledge and skills needed for training nurses at their institutions. [J Contin Educ Nurs. 2021;52(8):375-381.].
Collapse
|
8
|
Yamaguchi Y, Kamai T, Kobayashi M. Comparative accuracy of the Lilium α-200 portable ultrasound bladder scanner and conventional transabdominal ultrasonography for postvoid residual urine volume measurement in association with the clinical factors involved in measurement errors. Neurourol Urodyn 2020; 40:183-192. [PMID: 33022795 DOI: 10.1002/nau.24530] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Revised: 09/20/2020] [Accepted: 09/20/2020] [Indexed: 01/19/2023]
Abstract
AIM We examined the comparative accuracy of the portable ultrasound bladder scanner, Lilium α-200, and conventional ultrasonography (CUS) in bladder volume measurement. We also examined factors that could lead to measurement errors. METHODS Postvoid residual (PVR) volume was measured by Lilium α-200 and CUS with catheterized volume as a comparator in 224 consecutive men, of which 109 were also measured for the serially inflated bladder with saline. The measurement accuracy with respect to the actual volume was evaluated by calculating the error volume (EV), % error volume (%EV), and their absolute values. Absolute %EV of ≤20% was designated as nonerror. The measurement of prostate volume, abdominal thickness, and pelvimetry was performed on magnetic resonance images. RESULTS PVR volumes measured by CUS are better correlated with actual volumes (r = .779) than those of Lilium α-200 (r = .606). When the measurement accuracy was indicated by absolute values of EV and %EV, CUS provided a more accurate estimate (21 ± 21 ml, 60 ± 42%) than Lilium α-200 (32 ± 45 ml, 91 ± 142%). The frequency of error was significantly increased at lower bladder volumes. Overestimation was associated with larger prostate size for the Lilium α-200, while underestimation was associated with greater bladder flattening for both methods. CONCLUSION PVR volumes measured by Lilium α-200 were fairly correlated with actual volumes. However, their relative errors were too large to correctly predict the actual volume. Flattened bladder and a large prostate may hinder accurate measurements. Consequently, Lilium α-200 is not superior to CUS and its feasibility is limited to when the precise measurement is not required.
Collapse
Affiliation(s)
| | - Takao Kamai
- Department of Urology, Dokkyo Medical University, Tochigi, Japan
| | - Minoru Kobayashi
- Department of Urology, Utsunomiya Memorial Hospital, Tochigi, Japan
| |
Collapse
|
9
|
Abstract
PURPOSE OF REVIEW This manuscript reviews recent technological advances in ambulatory urodynamics. RECENT FINDINGS Ambulatory urodynamics is currently recommended by the International Continence Society as a second-line diagnostic tool in patients with nondiagnostic traditional urodynamics. Novel techniques involving telemetric monitoring are in development, which utilize catheter-free wireless systems to address several recognized shortcomings of inoffice urodynamic studies. Current research in catheter-free bladder pressure measurements involves either an intravesical, intradetrusor, or transdetrusor approach. Real-time bladder volume estimation may be performed using ultrasonography, near-infrared spectroscopy, or bladder volume conductance measurement. Ambulatory urodynamics can measure bladder function in the "real world" setting, capturing physiological bladder filling and emptying and allowing patients to reproduce the activities that may trigger their symptoms. Telemetric devices being developed represent further advances in this field and focus upon improving diagnostic capabilities, evaluating patient response to treatment, and facilitating closed-loop bladder control with neuroprosthetic integration.
Collapse
Affiliation(s)
- Neil J Kocher
- Cleveland Clinic, Glickman Urological & Kidney Institute, Cleveland, OH, USA
| | - Margot S Damaser
- Cleveland Clinic, Glickman Urological & Kidney Institute, Cleveland, OH, USA
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH, USA
- Department of Biomedical Engineering, Cleveland Clinic, Lerner Research Institute, Cleveland, OH, USA
| | - Bradley C Gill
- Cleveland Clinic, Glickman Urological & Kidney Institute, Cleveland, OH, USA.
- Division of Urology, Surgical Service, Louis Stokes Cleveland Veterans Affairs Medical Center, 9500 Euclid Ave, Cleveland, OH, 44195, USA.
| |
Collapse
|
10
|
Han X, Gao Y, Wang S, Chen Q. Effect of electroacupuncture on diabetic neurogenic bladder: A randomized controlled trial protocol. Medicine (Baltimore) 2020; 99:e19843. [PMID: 32332636 PMCID: PMC7220684 DOI: 10.1097/md.0000000000019843] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Accepted: 03/12/2020] [Indexed: 12/29/2022] Open
Abstract
BACKGROUND The most common and bothersome lower urinary tract complication of diabetes mellitus is diabetic neurogenic bladder (DNB). Acupuncture has certain advantages in treating bladder dysfunction including urinary retention and incontinence. Therefore, we think that electroacupuncture (EA) may be beneficial to DNB patients. However, it is not clear whether EA combined with basic western medicine could optimize the therapeutic effect for DNB. METHOD/DESIGN This is a sham-controlled, patient-blinded, pioneer randomized controlled trial (RCT). One hundred fifty eligible patients will be randomly divided into 3 groups: A. basic western medicine (BWC), B. EA with BWC, C. sham EA with BWC. EA treatment will be given twice a week for 12 weeks at bilateral BL23, BL32, BL33, and BL35. The BWC group will received Alpha-lipoic acid (ALA) and methylcobalamin (MC) treatment for 12 weeks, 2 treatment sessions per week. The primary outcome is scored by the 72-hour bladder diary (72h-BD). The secondary outcomes will be scored by the American Urological Association symptom index (AUA-SI), Post-void residual urine volume (PVR) and urodynamic tests. All the assessments will be conducted at baseline and the 12th weeks after the intervention starts. The follow-up assessments will be performed with 72h-BD and AUA-SI in the 4th, 12th, and 24th weeks after intervention ends. DISCUSSION This trial protocol provides an example of the clinical application acupuncture treatment in the management of DNB. This RCT will provide us information on the effect of treating DNB patients with only acupuncture, western medicine therapy (ALA + MC) as well as the combination of both. The additive effect or synergistic effect of acupuncture and basic western medicine will then be analyzed. TRIAL REGISTRATION Chinese Clinical Trial Registry, ChiCTR2000030421.
Collapse
Affiliation(s)
- Xuke Han
- Hospital of Chengdu University of Traditional Chinese Medicine
- Chengdu University of Traditional Chinese Medicine, Chengdu, Sichuan Province, China
| | - Yang Gao
- Hospital of Chengdu University of Traditional Chinese Medicine
- Chengdu University of Traditional Chinese Medicine, Chengdu, Sichuan Province, China
| | - Shengju Wang
- Hospital of Chengdu University of Traditional Chinese Medicine
- Chengdu University of Traditional Chinese Medicine, Chengdu, Sichuan Province, China
| | - Qiu Chen
- Hospital of Chengdu University of Traditional Chinese Medicine
| |
Collapse
|
11
|
Geritz J, Maetzold S, Steffen M, Pilotto A, Corrà MF, Moscovich M, Rizzetti MC, Borroni B, Padovani A, Alpes A, Bang C, Barcellos I, Baron R, Bartsch T, Becktepe JS, Berg D, Bergeest LM, Bergmann P, Bouça-Machado R, Drey M, Elshehabi M, Farahmandi S, Ferreira JJ, Franke A, Friederich A, Geisler C, Hüllemann P, Gierthmühlen J, Granert O, Heinzel S, Heller MK, Hobert MA, Hofmann M, Jemlich B, Kerkmann L, Knüpfer S, Krause K, Kress M, Krupp S, Kudelka J, Kuhlenbäumer G, Kurth R, Leypoldt F, Maetzler C, Maia LF, Moewius A, Neumann P, Niemann K, Ortlieb CT, Paschen S, Pham MH, Puehler T, Radloff F, Riedel C, Rogalski M, Sablowsky S, Schanz EM, Schebesta L, Schicketmüller A, Studt S, Thieves M, Tönges L, Ullrich S, Urban PP, Vila-Chã N, Wiegard A, Warmerdam E, Warnecke T, Weiss M, Welzel J, Hansen C, Maetzler W. Motor, cognitive and mobility deficits in 1000 geriatric patients: protocol of a quantitative observational study before and after routine clinical geriatric treatment - the ComOn-study. BMC Geriatr 2020; 20:45. [PMID: 32028945 PMCID: PMC7006407 DOI: 10.1186/s12877-020-1445-z] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2018] [Accepted: 01/27/2020] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Motor and cognitive deficits and consequently mobility problems are common in geriatric patients. The currently available methods for diagnosis and for the evaluation of treatment in this vulnerable cohort are limited. The aims of the ComOn (COgnitive and Motor interactions in the Older populatioN) study are (i) to define quantitative markers with clinical relevance for motor and cognitive deficits, (ii) to investigate the interaction between both motor and cognitive deficits and (iii) to assess health status as well as treatment outcome of 1000 geriatric inpatients in hospitals of Kiel (Germany), Brescia (Italy), Porto (Portugal), Curitiba (Brazil) and Bochum (Germany). METHODS This is a prospective, explorative observational multi-center study. In addition to the comprehensive geriatric assessment, quantitative measures of reduced mobility and motor and cognitive deficits are performed before and after a two week's inpatient stay. Components of the assessment are mobile technology-based assessments of gait, balance and transfer performance, neuropsychological tests, frailty, sarcopenia, autonomic dysfunction and sensation, and questionnaires to assess behavioral deficits, activities of daily living, quality of life, fear of falling and dysphagia. Structural MRI and an unsupervised 24/7 home assessment of mobility are performed in a subgroup of participants. The study will also investigate the minimal clinically relevant change of the investigated parameters. DISCUSSION This study will help form a better understanding of symptoms and their complex interactions and treatment effects in a large geriatric cohort.
Collapse
Affiliation(s)
- Johanna Geritz
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Sara Maetzold
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Maren Steffen
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Andrea Pilotto
- Department of Clinical and Experimental Sciences, Neurology Unit, University of Brescia, Brescia, Italy
| | - Marta F. Corrà
- Neurology Department, Centro Hospitalar do Porto, Porto, Portugal
| | - Mariana Moscovich
- Movement Disorders Unit, Neurology Service, Internal Medicine Department, Hospital de Clínicas, Federal University of Paraná, Curitiba, Brazil
| | - Maria C. Rizzetti
- Department of Clinical and Experimental Sciences, Neurology Unit, University of Brescia, Brescia, Italy
| | - Barbara Borroni
- Department of Clinical and Experimental Sciences, Neurology Unit, University of Brescia, Brescia, Italy
| | - Alessandro Padovani
- Department of Clinical and Experimental Sciences, Neurology Unit, University of Brescia, Brescia, Italy
| | - Annekathrin Alpes
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Corinna Bang
- Institute of Clinical Molecular Biology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Igor Barcellos
- Movement Disorders Unit, Neurology Service, Internal Medicine Department, Hospital de Clínicas, Federal University of Paraná, Curitiba, Brazil
| | - Ralf Baron
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Thorsten Bartsch
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Jos S. Becktepe
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Daniela Berg
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Lu M. Bergeest
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Philipp Bergmann
- Department of Internal Medicine I, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Raquel Bouça-Machado
- Instituto de Medicina Molecular, Lisbon, Portugal. CNS-Campus Neurológico Sénior, Torres Vedras, Portugal. Laboratory of Clinical Pharmacology and Therapeutics, Faculty of Medicine, University of Lisbon, Lisbon, Portugal
| | - Michael Drey
- Medical Clinic and Policlinic IV, Ludwig-Maximilians-University of Munich, Munich, Germany
| | - Morad Elshehabi
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Susan Farahmandi
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Joaquim J. Ferreira
- Instituto de Medicina Molecular, Lisbon, Portugal. CNS-Campus Neurológico Sénior, Torres Vedras, Portugal. Laboratory of Clinical Pharmacology and Therapeutics, Faculty of Medicine, University of Lisbon, Lisbon, Portugal
| | - Andre Franke
- Institute of Clinical Molecular Biology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Anja Friederich
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Corinna Geisler
- Institute of Human nutrition, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Philipp Hüllemann
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Janne Gierthmühlen
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Oliver Granert
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Sebastian Heinzel
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Maren K. Heller
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Markus A. Hobert
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | | | - Björn Jemlich
- Third Medical Clinic for Gastroenterology/Rheumatology, Städtisches Krankenhaus Kiel, Kiel, Germany
| | - Laura Kerkmann
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Stephanie Knüpfer
- Department of Urology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Katharina Krause
- Department of Internal Medicine I, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Maximilian Kress
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Sonja Krupp
- Research Group Geriatrics Lübeck, Red Cross Hospital Geriatric Centre, Lübeck, Germany
| | - Jennifer Kudelka
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Gregor Kuhlenbäumer
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Roland Kurth
- Department of Psychiatry and Psychotherapy, ZIP, Centre for Integrative Psychiatry, Kiel, Germany
| | - Frank Leypoldt
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Corina Maetzler
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Luis F. Maia
- Neurology Department, Centro Hospitalar do Porto, Porto, Portugal
| | - Andreas Moewius
- Department of Neurology, Ruhr-University Bochum, St. Josef-Hospital, Bochum, Germany
| | - Patricia Neumann
- Department of Neurology, Asklepios Klinik Barmbek, Hamburg, Germany
| | - Katharina Niemann
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | | | - Steffen Paschen
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Minh H. Pham
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
- Digital Signal Processing and System Theory, Faculty of Engineering, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Thomas Puehler
- Department of Cardiac and Vascular Surgery, Universitätsklinikum Schleswig-Holstein Campus Kiel, Kiel, Germany
| | - Franziska Radloff
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Christian Riedel
- Department of Radiology and Neuroradiology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Marten Rogalski
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Simone Sablowsky
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Elena M. Schanz
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Linda Schebesta
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
- Department of Cardiac and Vascular Surgery, Universitätsklinikum Schleswig-Holstein Campus Kiel, Kiel, Germany
| | | | - Simone Studt
- Department of Psychiatry and Psychotherapy, ZIP, Centre for Integrative Psychiatry, Kiel, Germany
| | - Martina Thieves
- Geriatric Clinic, Städtisches Krankenhaus Kiel, Kiel, Germany
| | - Lars Tönges
- Department of Neurology, Ruhr-University Bochum, St. Josef-Hospital, Bochum, Germany
| | - Sebastian Ullrich
- Third Medical Clinic for Gastroenterology/Rheumatology, Städtisches Krankenhaus Kiel, Kiel, Germany
| | - Peter P. Urban
- Department of Neurology, Asklepios Klinik Barmbek, Hamburg, Germany
| | - Nuno Vila-Chã
- Neurology Department, Centro Hospitalar do Porto, Porto, Portugal
| | - Anna Wiegard
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Elke Warmerdam
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
- Digital Signal Processing and System Theory, Faculty of Engineering, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Tobias Warnecke
- Department of Neurology, University Hospital Muenster, Muenster, Germany
| | - Michael Weiss
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Julius Welzel
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Clint Hansen
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| | - Walter Maetzler
- Department of Neurology, Christian-Albrechts-University of Kiel, Kiel, Germany
| |
Collapse
|
12
|
Jakubowski J, Moskovitz J, Leonard NJ. Imaging Modalities in Genitourinary Emergencies. Emerg Med Clin North Am 2019; 37:785-809. [PMID: 31563208 DOI: 10.1016/j.emc.2019.07.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Emergency physicians rely on a multitude of different imaging modalities in the diagnosis of genitourinary emergencies. There are many considerations to be taken into account when deciding which imaging modality should be used first, as oftentimes several diagnostic tools can be used for the same pathologic condition. These factors include radiation exposure, sensitivity, specificity, age of patient, availability of resources, cost, and timeliness of completion. In this review, the strengths and weaknesses of different imaging tools in the evaluation of genitourinary emergencies are discussed.
Collapse
Affiliation(s)
- Julian Jakubowski
- Department of Emergency Medicine, Emergency Medicine Residency Marietta Memorial Hospital, 401 Matthew Street, Marietta, OH 45750, USA; The Ohio University Heritage College of Osteopathic Medicine, Athens, OH, USA.
| | - Joshua Moskovitz
- Department of Emergency Medicine, Jacobi Medical Center, Albert Einstein College of Medicine, 1400 Pelham Parkway South, Building 6 Room 1B25, Bronx, NY 10461, USA; Hofstra School of Health and Human Services, Hempstead, NY, USA
| | - Nicole J Leonard
- Department of Emergency Medicine, Jacobi Montefiore Emergency Medicine Residency, 1400 Pelham Parkway South, Building 6, Bronx, NY 10461, USA
| |
Collapse
|
13
|
Matsumoto M, Tsutaoka T, Yabunaka K, Handa M, Yoshida M, Nakagami G, Sanada H. Development and evaluation of automated ultrasonographic detection of bladder diameter for estimation of bladder urine volume. PLoS One 2019; 14:e0219916. [PMID: 31487299 PMCID: PMC6728037 DOI: 10.1371/journal.pone.0219916] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Accepted: 07/03/2019] [Indexed: 12/01/2022] Open
Abstract
Bladder urine volume has been estimated using an ellipsoid method based on triaxial measurements of the bladder extrapolated from two-dimensional ultrasound images. This study aimed to automate this process and to determine the accuracy of the automated estimation method for normal and small amounts of urine. A training set of 81 pairs of transverse and longitudinal ultrasound images were collected from healthy volunteers on a tablet-type ultrasound device, and an automatic detection tool was developed using them. The tool was evaluated using paired transverse/longitudinal ultrasound images from 27 other healthy volunteers. After imaging, the participants voided and their urine volume was measured. For determining accuracy, regression coefficients were calculated between estimated bladder volume and urine volume. Further, sensitivity and specificity for 50 and 100 ml bladder volume thresholds were evaluated. Data from 50 procedures were included. The regression coefficient was very similar between the automatic estimation (β = 0.99, R2 = 0.96) and manual estimation (β = 1.05, R2 = 0.97) methods. The sensitivity and specificity of the automatic estimation method were 88.5% and 100.0%, respectively, for 100 ml and were 94.1% and 100.0%, respectively, for 50 ml. The newly-developed automated tool accurately and reliably estimated bladder volume at two different volume thresholds of approximately 50 ml and 100 ml.
Collapse
Affiliation(s)
- Masaru Matsumoto
- Department of Imaging Nursing Science, Graduate School of Medicine, The University of Tokyo, Bunkyo-ku, Tokyo, Japan
| | - Takuya Tsutaoka
- Department of Imaging Nursing Science, Graduate School of Medicine, The University of Tokyo, Bunkyo-ku, Tokyo, Japan
- Imaging Technology Center, Research & Development Management Headquarters, FUJIFILM Corporation, Minato-ku, Tokyo, Japan
| | - Koichi Yabunaka
- Department of Imaging Nursing Science, Graduate School of Medicine, The University of Tokyo, Bunkyo-ku, Tokyo, Japan
- Global Nursing Research Center, Graduate School of Medicine, The University of Tokyo, Bunkyo-ku, Tokyo, Japan
| | - Mayumi Handa
- Department of Imaging Nursing Science, Graduate School of Medicine, The University of Tokyo, Bunkyo-ku, Tokyo, Japan
- Marketing Planning Group, Ultrasound Promotion Department, FUJIFILM Medical Corporation, Minato-ku, Tokyo, Japan
| | - Mikako Yoshida
- Department of Imaging Nursing Science, Graduate School of Medicine, The University of Tokyo, Bunkyo-ku, Tokyo, Japan
| | - Gojiro Nakagami
- Global Nursing Research Center, Graduate School of Medicine, The University of Tokyo, Bunkyo-ku, Tokyo, Japan
- Department of Gerontological Nursing/Wound Care Management, Graduate School of Medicine, The University of Tokyo, Bunkyo-ku, Tokyo, Japan
| | - Hiromi Sanada
- Global Nursing Research Center, Graduate School of Medicine, The University of Tokyo, Bunkyo-ku, Tokyo, Japan
- Department of Gerontological Nursing/Wound Care Management, Graduate School of Medicine, The University of Tokyo, Bunkyo-ku, Tokyo, Japan
| |
Collapse
|
14
|
Janardanan S, Moussa AEM, James P. False positive bladder scan in ascites with anuria. Clin Case Rep 2019; 7:1549-1550. [PMID: 31428387 PMCID: PMC6693308 DOI: 10.1002/ccr3.2281] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2018] [Revised: 05/13/2019] [Accepted: 05/29/2019] [Indexed: 11/29/2022] Open
Abstract
Urinary retention is commonly diagnosed based on history and examination along with bedside bladder scan. However, in patients where clinical examination is unreliable (patients with obesity, anasarca, and ascites) and diagnosis is uncertain, the bladder scan findings should be interpreted with caution and definitive imaging is mandatory before further intervention is instituted.
Collapse
Affiliation(s)
| | | | - Philip James
- Ashford & St Peter’s NHS Trust HospitalChertseySurreyUK
| |
Collapse
|
15
|
Abelson B, Majerus S, Sun D, Gill BC, Versi E, Damaser MS. Ambulatory urodynamic monitoring: state of the art and future directions. Nat Rev Urol 2019; 16:291-301. [PMID: 30936468 PMCID: PMC6946055 DOI: 10.1038/s41585-019-0175-5] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Urodynamic studies are a key component of the clinical evaluation of lower urinary tract dysfunction and include filling cystometry, pressure-flow studies, uroflowmetry, urethral function tests and electromyography. However, pitfalls of traditional urodynamics include physical and emotional discomfort, artificial test conditions with catheters and rapid retrograde filling of the bladder, which result in variable diagnostic accuracy. Ambulatory urodynamic monitoring (AUM) uses physiological anterograde filling and, therefore, offers a longer and more physiologically relevant evaluation. However, AUM methods rely on traditional catheters and pressure transducers and do not measure volume continuously, which is required to provide context for pressure changes. Novel telemetric AUM (TAUM) methods that use wireless, catheter-free, battery-powered devices to monitor bladder pressure and volume while patients carry out their daily activities are currently being investigated. TAUM devices under current development are innovating in the areas of remote monitoring, rechargeable energy sources, device deployment and retrieval and materials engineering to provide increased diagnostic accuracy and improved comfort for patients with incontinence or voiding dysfunction. These devices hold promise for improving the diagnosis and management of patients with lower urinary tract disorders.
Collapse
Affiliation(s)
- Benjamin Abelson
- Cleveland Clinic, Glickman Urological & Kidney Institute, Cleveland, OH, USA
| | - Steve Majerus
- Advanced Platform Technology Center, Louis Stokes Cleveland VA Medical Center, Cleveland, OH, USA
- Cleveland Clinic, Lerner Research Institute, Department of Biomedical Engineering, Cleveland, OH, USA
| | - Daniel Sun
- Cleveland Clinic, Glickman Urological & Kidney Institute, Cleveland, OH, USA
| | - Bradley C Gill
- Cleveland Clinic, Glickman Urological & Kidney Institute, Cleveland, OH, USA
| | - Eboo Versi
- Department of Obstetrics, Gynecology and Reproductive Sciences, Robert Wood Johnson Medical School, Rutgers University, New Brunswick, NJ, USA
| | - Margot S Damaser
- Cleveland Clinic, Glickman Urological & Kidney Institute, Cleveland, OH, USA.
- Advanced Platform Technology Center, Louis Stokes Cleveland VA Medical Center, Cleveland, OH, USA.
- Cleveland Clinic, Lerner Research Institute, Department of Biomedical Engineering, Cleveland, OH, USA.
| |
Collapse
|
16
|
The Accuracy of Portable Ultrasound Bladder Scanner Measurements of Postvoid Residual Volume in Women With Pelvic Organ Prolapse. Female Pelvic Med Reconstr Surg 2018; 25:388-391. [PMID: 29424755 PMCID: PMC6727931 DOI: 10.1097/spv.0000000000000565] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The purpose of this study was to evaluate the accuracy of portable bladder scanner postvoid residual (PVR) volume measurements in patients with pelvic organ prolapse. A secondary goal was to determine whether covariates such as bladder volume and stage of prolapse affect bladder scanner accuracy.
Collapse
|
17
|
Chen SC, Chen PY, Chen GC, Chuang SY, Tzeng IS, Lin SK. Portable Bladder Ultrasound Reduces Incidence of Urinary Tract Infection and Shortens Hospital Length of Stay in Patients With Acute Ischemic Stroke. J Cardiovasc Nurs 2018; 33:551-558. [PMID: 29851660 PMCID: PMC6200369 DOI: 10.1097/jcn.0000000000000507] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
BACKGROUND Urinary tract infection (UTI) during acute ischemic stroke is associated with a longer hospital length of stay and unfavorable functional outcomes. OBJECTIVE We investigated the benefits of portable bladder ultrasound (PBU) scanning during acute ischemic stroke. METHODS We retrospectively reviewed patients with acute ischemic stroke from January 2011 to February 2017. Patients were divided into group 1 (PBU not available) and group 2 (PBU available), before or after the split date, April 9, 2014. Portable bladder ultrasound scanning was conducted by nurses to measure postvoid residual urine volume in patients with impaired consciousness and/or dependent ambulation. RESULTS In total, 1928 patients were enrolled, of whom 109 (5.7%) had UTI and 901 (46.7%) experienced unfavorable outcomes (modified Rankin scale score ≥ 3). Multivariate analysis revealed that factors that influenced UTI were age of 75 years or older, female gender, initial total National Institutes of Health Stroke Scale (NIHSS) score of 5 or higher, initial NIHSS conscious score of 1 or higher, initial NIHSS leg score of 2 or higher, and urinary catheterization. Factors influencing unfavorable outcomes were similar to those influencing UTI but further comprised UTI. C-statistic for UTI detection was 0.864 for model fitting, including significant factors in logistic regression. Compared with group 1, group 2 had a higher incidence of urinary catheterization (13.1% vs 8.2%), a lower incidence of UTI (4.0% vs 6.9%), and a shorter length of stay (11.9 vs 13.6 days). CONCLUSIONS Portable bladder ultrasound scanning reduced the incidence of UTI and shortened length of stay. We suggest routine PBU procedures for patients with acute ischemic stroke who fulfill the AGN3 criteria for a high risk of UTI.
Collapse
Affiliation(s)
- Shu-Chuan Chen
- Shu-Chuan Chen, RN Head Nurse, Department of Nursing, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taiwan. Pei-Ya Chen, MD Researcher, Stroke Center and Department of Neurology, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taiwan. Guei-Chiuan Chen, MD Researcher, Stroke Center and Department of Neurology, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taiwan. Su-Yun Chuang, RN Researcher, Infection Control Center, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taiwan. I-Shiang Tzeng, PhD Department of Research, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taiwan. Shinn-Kuang Lin, MD Associate Professor, Stroke Center and Department of Neurology, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, and School of Medicine, Tzu Chi University, Hualien, Taiwan
| | | | | | | | | | | |
Collapse
|
18
|
Prentice DM, Sona C, Wessman BT, Ablordeppey EA, Isakow W, Arroyo C, Schallom M. Discrepancies in measuring bladder volumes with bedside ultrasound and bladder scanning in the intensive care unit: A pilot study. J Intensive Care Soc 2017; 19:122-126. [PMID: 29796068 DOI: 10.1177/1751143717740805] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Objective Intensive care unit patients are at risk for catheter-associated urinary tract infection. Earlier removal of catheters may be possible with accurate measurement of bladder volume. The purpose was to compare measured bladder volumes with bedside ultrasound, bladder scanner, and urine volume. Design Prospective correlational descriptive study. Setting Surgical/trauma intensive care unit and medical intensive care unit. Patients Renal dialysis patients with less than 100 ml of urine in 24 h prior to urinary catheter removal and patients with suspected catheter obstruction. Measurements and main results A physician trained in ultrasound and an advanced practice registered nurse trained in bladder scanning measured bladder volume; each blinded to the other's measurement. Device used first (ultrasound or bladder scanner) alternated daily. The intensive care unit team determined need for intermittent catheterization or treatment for suspected obstruction. Fifty-one measurements from 13 patients were obtained with results reported in milliliters. Ultrasound measurements were a mean volume of 72.1 ± 127 (range: 1.7-666) and the bladder scanner measurements were 117 ± 131 (0-529). On six occasions in five dialysis patients, urine volume measurement was available. The mean difference in ultrasound-urine volume mean difference was 0.5 ± 37.8 (range: -68 to 38.2) and the bladder scanner-urine volume was 132 ± 167 (-72 to 397). Two patients with suspected catheter obstructions had ultrasound, bladder scanner, urine volume measurements, respectively: (1) 539, 51, >300 (began voiding before catheter replaced); (2) 666, 68, 1000 with catheter replacement. Conditions leading to greatest differences were obesity, indwelling catheter and ascites. Conclusions These results demonstrate the inaccuracy of the bladder scanner. Ultrasound measurements appear more accurate. To remove urinary catheters in patients with minimal to low urine output, serial ultrasound measurements can be used to monitor bladder volumes and return of renal function.
Collapse
Affiliation(s)
| | | | - Brian T Wessman
- 2Department of Anesthesiology and Emergency Medicine, Washington University School of Medicine, St. Louis, MO, USA
| | - Enyo A Ablordeppey
- 2Department of Anesthesiology and Emergency Medicine, Washington University School of Medicine, St. Louis, MO, USA
| | - Warren Isakow
- 3Department of Pulmonary Medicine, Washington University School of Medicine, St. Louis, MO, USA
| | | | | |
Collapse
|
19
|
Noguchi N, Chan L, Cumming RG, Blyth FM, Handelsman DJ, Waite LM, Le Couteur DG, Naganathan V. Natural history of post-void residual urine volume over 5 years in community-dwelling older men: The Concord Health and Ageing in Men Project. Neurourol Urodyn 2017; 37:1068-1073. [PMID: 28940729 DOI: 10.1002/nau.23415] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2017] [Accepted: 08/24/2017] [Indexed: 11/09/2022]
Abstract
AIMS To describe the natural history of post-void residual urine volume (PVR) in community-dwelling older men. METHODS The Concord Health and Ageing in Men Project involves a representative sample of community-dwelling men aged 70 and older in a defined geographic area of Sydney, Australia. PVR were measured at baseline and 2-year and 5-year follow-up. The measurements were considered valid when the voided volumes were 150 mL and over. Three-hundred twenty-nine men without conditions that are likely to alter PVR (neurological disorders, prostate cancer, and a history of urological treatment) were included in the analyses. RESULTS Baseline PVR were 0-49 mL in 183 men, 50-99 mL in 59 men, 100-199 mL in 72 men, 200-399 mL in 11 men, and 400 mL and over in 4 men. Thirteen out of 314 (4%) men with a baseline PVR of 0-199 mL and 2 out of 11 (18%) men with a baseline PVR of 200-399 mL had surgery for benign prostate enlargement (BPE) or indwelling catheterization over 5 years compared to three out of four men (75%) with a PVR of 400 mL and over. In all 101 men with a baseline PVR of less than 400 mL who did not receive urological treatment during follow-up and had valid PVR data for both 2-year and 5-year follow-up, PVR did not exceed 400 mL at either follow-up time point. CONCLUSION Conservative management may be appropriate for most older men with incidentally found elevated PVR of up to 400 mL.
Collapse
Affiliation(s)
- Naomi Noguchi
- Centre for Education and Research on Ageing and Ageing and Alzheimer's Institute, Concord Hospital, University of Sydney, New South Wales, Australia.,Department of Urology, Concord Hospital, University of Sydney, New South Wales, Australia
| | - Lewis Chan
- School of Public Health, University of Sydney, New South Wales, Australia
| | - Robert G Cumming
- Centre for Education and Research on Ageing and Ageing and Alzheimer's Institute, Concord Hospital, University of Sydney, New South Wales, Australia.,Department of Urology, Concord Hospital, University of Sydney, New South Wales, Australia
| | - Fiona M Blyth
- Centre for Education and Research on Ageing and Ageing and Alzheimer's Institute, Concord Hospital, University of Sydney, New South Wales, Australia
| | - David J Handelsman
- ANZAC Research Institute, Concord Hospital, University of Sydney, New South Wales, Australia
| | - Louise M Waite
- Centre for Education and Research on Ageing and Ageing and Alzheimer's Institute, Concord Hospital, University of Sydney, New South Wales, Australia
| | - David G Le Couteur
- Centre for Education and Research on Ageing and Ageing and Alzheimer's Institute, Concord Hospital, University of Sydney, New South Wales, Australia.,ANZAC Research Institute, Concord Hospital, University of Sydney, New South Wales, Australia
| | - Vasi Naganathan
- Centre for Education and Research on Ageing and Ageing and Alzheimer's Institute, Concord Hospital, University of Sydney, New South Wales, Australia
| |
Collapse
|
20
|
Okçelik S, Soydan H, Ateş F, Yilmaz Ö, Malkoç E, Şenkul T, Karademir K. Correlation Between Residual Volume of Male Patients After Uroflowmetry and Random Residual Volume. Low Urin Tract Symptoms 2017. [PMID: 28643427 DOI: 10.1111/luts.12162] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
OBJECTIVES Our aim was to examine correlation between Post-void residual urine (PVR) after uroflowmetry and random PVR. METHODS Male patients reporting to the Urology outpatient clinic with LUTS were selected. Patients' age, prostate volume, bladder capacity, voided volume, maximum flow rate, average flow rate, random PVR and PVR after uroflowmetry were recorded. We evaluated the correlations between these parameters. Also we assessed if there was a difference between random PVR and PVR after uroflowmetry. We divided PVR after uroflowmetry and random PVR into three groups: Group 1: 0-50 mL, Group 2: 51-100 mL and Group 3: >100 mL. Also we divided the patients into two groups according to bladder capacity as Group 1: ≤400 mL and Group 2: >400 mL. We compared these groups to determine whether a significant difference. RESULTS Seventy-seven patients applying to the urology outpatient clinic were assessed between 2013 and 2014. PVR after uroflowmetry was significantly higher than random PVR (P < 0.001). When we divided PVR after uroflowmetry and random PVR into three groups there was a significant difference between the groups (P = 0.02). When we divided the patients into two groups according to bladder capacity as Group 1: ≤400 mL and Group 2: >400 mL, PVR after uroflowmetry was different, but random PVR was similar (P < 0.001, P = 0.72). CONCLUSIONS PVR after uroflowmetry seems to be incorrectly high in patients whose bladder capacity is above 400 mL.
Collapse
Affiliation(s)
- Sezgin Okçelik
- Department of Urology, Van Teaching and Research Hospital, Van, Turkey
| | - Hasan Soydan
- Department of Urology, Haydarpasa Sultan Abdulhamid Teaching and Research Hospital, Istanbul, Turkey
| | - Ferhat Ateş
- Department of Urology, Haydarpasa Sultan Abdulhamid Teaching and Research Hospital, Istanbul, Turkey
| | - Ömer Yilmaz
- Department of Urology, Haydarpasa Sultan Abdulhamid Teaching and Research Hospital, Istanbul, Turkey
| | - Ercan Malkoç
- Department of Urology, Haydarpasa Sultan Abdulhamid Teaching and Research Hospital, Istanbul, Turkey
| | - Temuçin Şenkul
- Department of Urology, Haydarpasa Sultan Abdulhamid Teaching and Research Hospital, Istanbul, Turkey
| | - Kenan Karademir
- Department of Urology, Haydarpasa Sultan Abdulhamid Teaching and Research Hospital, Istanbul, Turkey
| |
Collapse
|
21
|
Kim TH, Kim HS, Park JW, Lim OK, Park KD, Lee JK. Falsely Elevated Postvoid Residual Urine Volume in Uterine Myoma. Ann Rehabil Med 2017; 41:332-336. [PMID: 28503470 PMCID: PMC5426254 DOI: 10.5535/arm.2017.41.2.332] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2016] [Accepted: 07/11/2016] [Indexed: 11/23/2022] Open
Abstract
Precise measurement of postvoid residual (PVR) urine volume is a key factor in assessing patients with voiding dysfunction, including those with lower urinary tract problems. The safe and noninvasive ultrasound bladder scan is the preferred mode to measure PVR volume. However, this procedure has a false-positive rate up to 9%, in the presence of ovarian cysts, renal cysts, ascites, or uterine myoma with cystic degeneration. Until now, cystic lesions are known to cause false positivity in ultrasound bladder scanner. However, we encountered falsely-elevated PVR in two cases of non-cystic uterine myomas. We present these cases with detailed radiologic images and volume measurement data.
Collapse
Affiliation(s)
- Tae Hee Kim
- Department of Rehabilitation Medcine, Gachon University Gil Medical Center, Incheon, Korea
| | - Hyo Sang Kim
- Department of Rehabilitation Medcine, Gachon University Gil Medical Center, Incheon, Korea
| | - Jung Wook Park
- Department of Rehabilitation Medcine, Gachon University Gil Medical Center, Incheon, Korea
| | - Oh Kyung Lim
- Department of Rehabilitation Medcine, Gachon University College of Medicine, Incheon, Korea
| | - Ki Deok Park
- Department of Rehabilitation Medcine, Gachon University College of Medicine, Incheon, Korea
| | - Ju Kang Lee
- Department of Rehabilitation Medcine, Gachon University College of Medicine, Incheon, Korea
| |
Collapse
|
22
|
Cho MK, Noh EJ, Kim CH. Accuracy and precision of a new portable ultrasound scanner, the Biocon-700, in residual urine volume measurement. Int Urogynecol J 2016; 28:1057-1061. [DOI: 10.1007/s00192-016-3224-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2016] [Accepted: 11/21/2016] [Indexed: 10/20/2022]
|
23
|
Wang J, Zhai Y, Wu J, Zhao S, Zhou J, Liu Z. Acupuncture for Chronic Urinary Retention due to Spinal Cord Injury: A Systematic Review. EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE : ECAM 2016; 2016:9245186. [PMID: 27190542 PMCID: PMC4846757 DOI: 10.1155/2016/9245186] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2016] [Revised: 03/20/2016] [Accepted: 03/22/2016] [Indexed: 11/17/2022]
Abstract
No systematic review has been published on the use of acupuncture for the treatment of chronic urinary retention (CUR) due to spinal cord injury (SCI). The aim of this review was to assess the effectiveness and safety of acupuncture for CUR due to SCI. Three randomized controlled trials (RCTs) including 334 patients with CUR due to SCI were included. Meta-analysis showed that acupuncture plus rehabilitation training was much better than rehabilitation training alone in decreasing postvoid residual (PVR) urine volume (MD -109.44, 95% CI -156.53 to -62.35). Likewise, a combination of acupuncture and aseptic intermittent catheterization was better than aseptic intermittent catheterization alone in improving response rates (RR 1.23, 95% CI 1.10 to 1.38). No severe adverse events were reported. In conclusion, acupuncture as a complementary therapy may have a potential effect in CUR due to SCI in decreasing PVR and improving bladder voiding. Additionally, acupuncture may be safe in treating CUR caused by SCI. However, due to the lack of high quality RCTs, we could not draw any definitive conclusions. More well-designed RCTs are needed to provide strong evidence.
Collapse
Affiliation(s)
- Jia Wang
- Department of Acupuncture, Guang'anmen Hospital, China Academy of Chinese Medical Sciences, No. 5 Beixiange Street, Xicheng District, Beijing 100053, China
| | - Yanbing Zhai
- Department of Acupuncture, Guang'anmen Hospital, China Academy of Chinese Medical Sciences, No. 5 Beixiange Street, Xicheng District, Beijing 100053, China
- Beijing University of Chinese Medicine, No. 11 North Third Ring Road, Chaoyang District, Beijing 100029, China
| | - Jiani Wu
- Department of Acupuncture, Guang'anmen Hospital, China Academy of Chinese Medical Sciences, No. 5 Beixiange Street, Xicheng District, Beijing 100053, China
| | - Shitong Zhao
- Beijing University of Chinese Medicine, No. 11 North Third Ring Road, Chaoyang District, Beijing 100029, China
| | - Jing Zhou
- Beijing University of Chinese Medicine, No. 11 North Third Ring Road, Chaoyang District, Beijing 100029, China
| | - Zhishun Liu
- Department of Acupuncture, Guang'anmen Hospital, China Academy of Chinese Medical Sciences, No. 5 Beixiange Street, Xicheng District, Beijing 100053, China
| |
Collapse
|
24
|
Ostle Z. Assessment, diagnosis and treatment of urinary incontinence in women. ACTA ACUST UNITED AC 2016; 25:84-91. [DOI: 10.12968/bjon.2016.25.2.84] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Zoe Ostle
- Specialist Nurse, Bladder and Bowel Service, South Tyneside NHS Foundation Trust
| |
Collapse
|
25
|
Dogan Z, Yalcin A, Atmis V, Cengiz O, Aras S, Varli M, Cinar E, Atli T. The prevalence of urinary incontinence and factors associated with urinary incontinence in community dwelling older Turkish people. Eur Geriatr Med 2015. [DOI: 10.1016/j.eurger.2015.06.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
26
|
Ding J, Chen C, Song XC, Zhang L, Deng M, Zhu L. Changes in Prolapse and Urinary Symptoms After Successful Fitting of a Ring Pessary With Support in Women With Advanced Pelvic Organ Prolapse: A Prospective Study. Urology 2015; 87:70-5. [PMID: 26375847 DOI: 10.1016/j.urology.2015.07.025] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2015] [Revised: 07/16/2015] [Accepted: 07/20/2015] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To estimate the percentage of improvement in prolapse and urinary symptoms and adverse effects in women with advanced pelvic organ prolapse (POP) after 3 months of use of a ring pessary with support. MATERIALS AND METHODS In this prospective study, 109 consecutive women with advanced POP were fitted with a ring pessary with support; 73 (73/109, 67.0%) of the women had a successful 3-month pessary fitting trial. Prolapse symptoms, urinary symptoms, and urinary flow parameters were assessed at baseline and at 3 months. Adverse effects were assessed within 3 months. McNemar's test and paired-sample t tests were performed. RESULTS Prolapse and urinary symptoms improved from baseline to 3 months, including bulging (90.4% to 23.3%; P <.001) and pressure (64.4% to 13.7%; P <.001). Voiding difficulty improved in 97.8% of the women (45/46; P <.001), splinting improved in 100% (19/19; P <.001), urge urinary incontinence improved in 76.9% (30/39; P <.001), and stress urinary incontinence improved in 58.1% (18/31; P = .025) after 3 months. After pessary treatment, the differences in maximum flow rate, mean flow rate, void volume, and postvoid residual at baseline and 3 months were statistically significant (P <.05). Vaginal discharge (32/73, 43.8%) was the most common adverse event. Vaginal ulcers developed in 7 (7/73, 9.6%) of the women. CONCLUSION The ring pessary with support was successfully fitted in patients with advanced POP with a high success rate and few complications. The pessary could resolve more than half of the prolapse and urinary symptoms. Therefore, initial conservative treatment with a ring pessary with support in advanced POP is worthwhile.
Collapse
Affiliation(s)
- Jing Ding
- Departments of Obstetrics and Gynecology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China.
| | - Chun Chen
- Departments of Obstetrics and Gynecology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
| | - Xiao-Chen Song
- Departments of Obstetrics and Gynecology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
| | - Lei Zhang
- Departments of Obstetrics and Gynecology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
| | - Mou Deng
- Departments of Obstetrics and Gynecology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
| | - Lan Zhu
- Departments of Obstetrics and Gynecology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China.
| |
Collapse
|
27
|
Asimakopoulos AD, De Nunzio C, Kocjancic E, Tubaro A, Rosier PF, Finazzi-Agrò E. Measurement of post-void residual urine. Neurourol Urodyn 2014; 35:55-7. [DOI: 10.1002/nau.22671] [Citation(s) in RCA: 68] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2014] [Accepted: 08/01/2014] [Indexed: 11/08/2022]
Affiliation(s)
| | - Cosimo De Nunzio
- Department of Urology; Sant'Andrea Hospital; Faculty of Health Sciences “La Sapienza” University of Rome; Rome Italy
| | - Ervin Kocjancic
- Director division of Pelvic Health and Reconstructive Urology; Department of Urology; University of Illinois at Chicago; Chicago Illinois
| | - Andrea Tubaro
- Department of Urology; Sant'Andrea Hospital; Faculty of Health Sciences “La Sapienza” University of Rome; Rome Italy
| | - Peter F. Rosier
- University Medical Centre Utrecht; Department of Urology; Utrecht The Netherlands
| | - Enrico Finazzi-Agrò
- Unit for Functional Urology; Policlinico Tor Vergata; Department of Experimental Medicine and Surgery; Tor Vergata University of Rome; Rome Italy
| |
Collapse
|
28
|
Jalbani IK, Ather MH. The accuracy of three-dimensional bladder ultrasonography in determining the residual urinary volume compared with conventional catheterisation. Arab J Urol 2014; 12:209-13. [PMID: 26019951 PMCID: PMC4435769 DOI: 10.1016/j.aju.2014.05.001] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2013] [Revised: 04/23/2014] [Accepted: 05/03/2014] [Indexed: 11/23/2022] Open
Abstract
Objective To determine the accuracy of three-dimensional bladder ultrasonography (US, using the BVI 3000, Verathon, WA, USA) for determining the residual urinary volume, compared with the conventional catheterisation method. Patients and methods We conducted a cross-sectional study at day-care unit of a University hospital after obtaining approval from the Ethics Review Committee of the hospital. Thirty-four patients with lower urinary tract symptoms requiring cystometrography were included. The postvoid volume was measured by bladder US, with three readings taken, and then patient was catheterised using a 12-F Nelaton catheter to measure the urinary volume. The mean of the three readings was compared with the catheterisation volume. Results The mean (SD) urinary volumes by US and catheterisation were 261 (186) and 260 (175) mL, respectively, and the correlation (r2) was 0.97. There was no effect of age, gender or body mass index on the accuracy of bladder US, which was accurate even when the urinary volume was ⩽100 mL. Conclusion The bladder US estimate is as accurate as catheterisation for determining the postvoid residual urinary volume. Its accuracy was also comparable when the urinary volume is <100 mL, and there was no significant effect of age, gender and body mass index. This system could replace the more invasive catheterisation, and with excellent accuracy.
Collapse
Affiliation(s)
- Imran K Jalbani
- Department of Surgery, Aga Khan University, Karachi, Pakistan
| | - M Hammad Ather
- Department of Surgery, Aga Khan University, Karachi, Pakistan
| |
Collapse
|
29
|
The usefulness of bladder reconditioning before indwelling urethral catheter removal from stroke patients. Am J Phys Med Rehabil 2012; 91:681-8. [PMID: 22660367 DOI: 10.1097/phm.0b013e31825a0a1b] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVE The aim of this study was to determine the effects of bladder reconditioning by indwelling urethral catheter (IUC) clamping before IUC removal in stroke patients. DESIGN Sixty patients with stroke were randomized to 0-, 1-, and 3-day IUC clamping groups. IUCs were removed without clamping in the 0-day group. In the other two groups, IUCs were clamped for 4 hrs followed by 5 mins of urinary drainage, a cycle repeated over 24 hrs in the 1-day and over 72 hrs in the 3-day clamping groups. Time to first voiding (FV), first voided volume (FV-vol), residual urine volume after FV, mean void volume, and residual urine volume on the third day after IUC removal were measured. We also recorded the voiding method such as self-voiding or intermittent catheterization, incidence of urinary tract infection, subjective complaints, and other complications. RESULTS Time to FV, FV-vol, residual urine volume after FV, voiding method, mean voided volume, and residual urine volume on the third day after IUC removal had no significant difference among three groups, nor between the 0-day and the other two clamping groups. We observed a strong negative correlation between age and FV-vol. Of the patients in the 1- and 3-day clamping groups, 3 (7.5%) had symptomatic urinary tract infection and 9 (22.5%) complained of urinary leakage during IUC clamping program. CONCLUSIONS Bladder reconditioning through IUC clamping has no noticeable benefits in stroke patients and may induce additional problems. These findings suggest that IUC removal without clamping is superior to IUC clamping for bladder reconditioning in stroke patients.
Collapse
|
30
|
Deffieux X, Thubert T, Amarenco G. Apport des explorations complémentaires au cours du bilan d’une dysurie de la femme. Prog Urol 2012; 22:628-35. [DOI: 10.1016/j.purol.2012.08.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2012] [Accepted: 08/08/2012] [Indexed: 10/27/2022]
|
31
|
ZAOUTER C, WUETHRICH P, MICCOLI M, CARLI F. Early removal of urinary catheter leads to greater post-void residuals in patients with thoracic epidural. Acta Anaesthesiol Scand 2012; 56:1020-5. [PMID: 22524633 DOI: 10.1111/j.1399-6576.2012.02701.x] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/06/2012] [Indexed: 11/27/2022]
Abstract
BACKGROUND A recent study showed that the removal of a bladder catheter is safe in presence of thoracic epidural analgesia (TEA). However, the ability to void satisfactorily can be affected. The aim of this investigation is to determine whether patients with TEA are able to recover the micturition process. METHODS On the morning after the surgery patients were randomised into two groups: the early removal group (ERG) (n = 101), with the bladder catheter removed at the same time, and the standard group (SG) (n = 104), where the bladder catheter was kept as long as TEA was functioning (on average 3-5 days after surgery). Following the first micturition, patients underwent regular ultrasound scanning of the bladder until a post-void residual (PVR) less than 200 ml was reached. RESULTS All of the patients in the ERG and in the SG started to void and recovered satisfactorily their ability to void, reaching a PVR < 200 ml without requiring a transurethral catheterisation. However, the length of time to reach a PVR < 200 ml in the ERG was significantly longer compared with the SG (345 min ± 169 vs. 207 min ± 122, P < 0.0001). CONCLUSION In the presence of TEA, the removal of the bladder catheter on the morning after surgery leads to a transient impairment of the lower urinary tract function with no need for re-catheterisation.
Collapse
Affiliation(s)
- C. ZAOUTER
- Department of Anesthesia; University of Pisa; Pisa; Italy
| | - P. WUETHRICH
- University Department of Anaesthesiology and Pain Therapy; Inselspital; Berne; Switzerland
| | - M. MICCOLI
- Epidemiology and Biostatistics Unit's Research; Department of Experimental Pathology M.B.I.E.; University of Pisa; Pisa; Italy
| | - F. CARLI
- Department of Anesthesia; McGill University Health Centre; Montreal; QC; Canada
| |
Collapse
|