1
|
Ogier AC, Bustin A, Cochet H, Schwitter J, van Heeswijk RB. The Road Toward Reproducibility of Parametric Mapping of the Heart: A Technical Review. Front Cardiovasc Med 2022; 9:876475. [PMID: 35600490 PMCID: PMC9120534 DOI: 10.3389/fcvm.2022.876475] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Accepted: 04/11/2022] [Indexed: 01/02/2023] Open
Abstract
Parametric mapping of the heart has become an essential part of many cardiovascular magnetic resonance imaging exams, and is used for tissue characterization and diagnosis in a broad range of cardiovascular diseases. These pulse sequences are used to quantify the myocardial T1, T2, T2*, and T1ρ relaxation times, which are unique surrogate indices of fibrosis, edema and iron deposition that can be used to monitor a disease over time or to compare patients to one another. Parametric mapping is now well-accepted in the clinical setting, but its wider dissemination is hindered by limited inter-center reproducibility and relatively long acquisition times. Recently, several new parametric mapping techniques have appeared that address both of these problems, but substantial hurdles remain for widespread clinical adoption. This review serves both as a primer for newcomers to the field of parametric mapping and as a technical update for those already well at home in it. It aims to establish what is currently needed to improve the reproducibility of parametric mapping of the heart. To this end, we first give an overview of the metrics by which a mapping technique can be assessed, such as bias and variability, as well as the basic physics behind the relaxation times themselves and what their relevance is in the prospect of myocardial tissue characterization. This is followed by a summary of routine mapping techniques and their variations. The problems in reproducibility and the sources of bias and variability of these techniques are reviewed. Subsequently, novel fast, whole-heart, and multi-parametric techniques and their merits are treated in the light of their reproducibility. This includes state of the art segmentation techniques applied to parametric maps, and how artificial intelligence is being harnessed to solve this long-standing conundrum. We finish up by sketching an outlook on the road toward inter-center reproducibility, and what to expect in the future.
Collapse
Affiliation(s)
- Augustin C. Ogier
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, University of Lausanne, Lausanne, Switzerland
| | - Aurelien Bustin
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, University of Lausanne, Lausanne, Switzerland
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Bordeaux, France
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Avenue de Magellan, Pessac, France
| | - Hubert Cochet
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Bordeaux, France
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Avenue de Magellan, Pessac, France
| | - Juerg Schwitter
- Cardiac MR Center, Cardiology Service, Lausanne University Hospital, University of Lausanne, Lausanne, Switzerland
| | - Ruud B. van Heeswijk
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, University of Lausanne, Lausanne, Switzerland
- *Correspondence: Ruud B. van Heeswijk
| |
Collapse
|
2
|
Weingärtner S, Desmond KL, Obuchowski NA, Baessler B, Zhang Y, Biondetti E, Ma D, Golay X, Boss MA, Gunter JL, Keenan KE, Hernando D. Development, validation, qualification, and dissemination of quantitative MR methods: Overview and recommendations by the ISMRM quantitative MR study group. Magn Reson Med 2021; 87:1184-1206. [PMID: 34825741 DOI: 10.1002/mrm.29084] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 10/20/2021] [Accepted: 10/27/2021] [Indexed: 12/26/2022]
Abstract
On behalf of the International Society for Magnetic Resonance in Medicine (ISMRM) Quantitative MR Study Group, this article provides an overview of considerations for the development, validation, qualification, and dissemination of quantitative MR (qMR) methods. This process is framed in terms of two central technical performance properties, i.e., bias and precision. Although qMR is confounded by undesired effects, methods with low bias and high precision can be iteratively developed and validated. For illustration, two distinct qMR methods are discussed throughout the manuscript: quantification of liver proton-density fat fraction, and cardiac T1 . These examples demonstrate the expansion of qMR methods from research centers toward widespread clinical dissemination. The overall goal of this article is to provide trainees, researchers, and clinicians with essential guidelines for the development and validation of qMR methods, as well as an understanding of necessary steps and potential pitfalls for the dissemination of quantitative MR in research and in the clinic.
Collapse
Affiliation(s)
- Sebastian Weingärtner
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | - Kimberly L Desmond
- Brain Health Imaging Centre, Centre for Addiction and Mental Health, Toronto, Ontario, Canada.,Department of Psychiatry, University of Toronto, Toronto, Ontario, Canada
| | - Nancy A Obuchowski
- Department of Quantitative Health Sciences, Cleveland Clinic, Cleveland, Ohio, USA
| | - Bettina Baessler
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland
| | - Yuxin Zhang
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Emma Biondetti
- Department of Neuroscience, Imaging and Clinical Sciences, D'Annunzio University of Chieti and Pescara, Chieti, Italy
| | - Dan Ma
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA
| | - Xavier Golay
- Brain Repair & Rehabilitation, Institute of Neurology, University College London, United Kingdom.,Gold Standard Phantoms Limited, Rochester, United Kingdom
| | - Michael A Boss
- Center for Research and Innovation, American College of Radiology, Philadelphia, Pennsylvania, USA
| | | | - Kathryn E Keenan
- National Institute of Standards and Technology, Boulder, Colorado, USA
| | - Diego Hernando
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | | |
Collapse
|
3
|
Han PK, Marin T, Djebra Y, Landes V, Zhuo Y, El Fakhri G, Ma C. Free-breathing 3D cardiac T 1 mapping with transmit B 1 correction at 3T. Magn Reson Med 2021; 87:1832-1845. [PMID: 34812547 DOI: 10.1002/mrm.29097] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Revised: 10/12/2021] [Accepted: 11/05/2021] [Indexed: 12/22/2022]
Abstract
PURPOSE To develop a cardiac T1 mapping method for free-breathing 3D T1 mapping of the whole heart at 3 T with transmit B1 ( B 1 + ) correction. METHODS A free-breathing, electrocardiogram-gated inversion-recovery sequence with spoiled gradient-echo readout was developed and optimized for cardiac T1 mapping at 3 T. High-frame-rate dynamic images were reconstructed from sparse (k,t)-space data acquired along a stack-of-stars trajectory using a subspace-based method for accelerated imaging. Joint T1 and flip-angle estimation was performed in T1 mapping to improve its robustness to B 1 + inhomogeneity. Subject-specific timing of data acquisition was used in the estimation to account for natural heart-rate variations during the imaging experiment. RESULTS Simulations showed that accuracy and precision of T1 mapping can be improved with joint T1 and flip-angle estimation and optimized electrocardiogram-gated spoiled gradient echo-based inversion-recovery acquisition scheme. The phantom study showed good agreement between the T1 maps from the proposed method and the reference method. Three-dimensional cardiac T1 maps (40 slices) were obtained at a 1.9-mm in-plane and 4.5-mm through-plane spatial resolution from healthy subjects (n = 6) with an average imaging time of 14.2 ± 1.6 minutes (heartbeat rate: 64.2 ± 7.1 bpm), showing myocardial T1 values comparable to those obtained from modified Look-Locker inversion recovery. The proposed method generated B 1 + maps with spatially smooth variation showing 21%-32% and 11%-15% variations across the septal-lateral and inferior-anterior regions of the myocardium in the left ventricle. CONCLUSION The proposed method allows free-breathing 3D T1 mapping of the whole heart with transmit B1 correction in a practical imaging time.
Collapse
Affiliation(s)
- Paul Kyu Han
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA.,Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Thibault Marin
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA.,Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Yanis Djebra
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA.,Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA.,LTCI, Télécom Paris, Institut Polytechnique de Paris, France
| | | | - Yue Zhuo
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA.,Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Georges El Fakhri
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA.,Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Chao Ma
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA.,Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
4
|
Evaluation of liver T1 using MOLLI gradient echo readout under the influence of fat. Magn Reson Imaging 2021; 85:57-63. [PMID: 34678435 DOI: 10.1016/j.mri.2021.10.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2021] [Revised: 10/14/2021] [Accepted: 10/16/2021] [Indexed: 11/22/2022]
Abstract
BACKGROUND The effect of hepatic steatosis on the gradient-echo (GRE) based Modified Look-Locker Inversion Recovery (MOLLI) technique for T1 mapping has not been evaluated. The purpose of this study was to evaluate a GRE based MOLLI technique for hepatic T1 mapping and determine the relationship of T1 differences (ΔT1) on in-phase (IP) and out-of-phase (OP) to fat fraction (FF) measurement. MATERIALS AND METHODS 3 T MRI included MOLLI T1 mapping with TE = 1.3 (OP), 2.4 (IP), and 1.8 ms, and chemical-shift-encoded sequence with spectral modeling of fat to generate FF map as a reference. Bloch simulations and oil/water phantoms were used to characterize the response of the MOLLI T1 in various FF < 30% since MOLLI T1 estimation was erratic beyond this limit. Curve fit between ΔT1 and FF from simulation was applied to validate the phantom and the in-vivo results. Thirty-eight normal volunteers were included (16 women, Age 44 ± 12 years, BMI 27 ± 5.3 kg/m2). MOLLI water images were reconstructed by the average of OP and IP images, and the T1 values on water images served as the reference for T1 bias calculation defined as the percent difference between OP, IP, TE = 1.8 ms and the referenced water T1. Linear regression was performed to correlate the FF quantified by the reference and MOLLI methods. RESULTS Phantom results were consistent with the Bloch simulations. The simulated relationship between FF (0-30%) and ΔT1 could be modeled precisely by a cubic equation with R2 = 1. In-vivo MOLLI ΔT1 and estimated FF were correlated to the reference FF (both R2 ≥ 0.96 and P < 0.001). TE = 1.8 ms demonstrated less T1 bias (-1.34%) compared to TE = OP (5.32%) or IP (-3.8%, both P < 0.001). CONCLUSION At 3 T, TE of 1.8 ms can be used to reduce the T1 bias and deliver consistent T1 values when FF is <30%.
Collapse
|
5
|
Takasumi H, Seino S, Kikori K, Ishikawa H, Kanezawa T, Bannae S, Kuhara S, Doi K. Evaluation of the homogeneity of native T1 myocardial mapping using the polarity corrected inversion time preparation method in a myocardial phantom and healthy volunteers. Radiol Phys Technol 2021; 14:50-56. [PMID: 33387358 DOI: 10.1007/s12194-020-00601-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Revised: 11/26/2020] [Accepted: 12/07/2020] [Indexed: 10/22/2022]
Abstract
Myocardial T1 mapping is a useful technique for the diagnosis of diffuse fibrosis. Although modified look-locker inversion recovery is a widely used T1 mapping method, variation in T1 values has been reported. Non-uniform T1 maps may hinder differentiation between healthy and diseased myocardial tissue. The purpose of this study was to investigate the uniformity of T1 mapping using polarity corrected inversion time preparation (PC TI prep) in a myocardial phantom and healthy volunteers. The myocardial phantom was scanned between polyvinyl alcohol (PVA) and air. T1 values were measured using inversion recovery fast spin-echo (IR-FSE) and PC TI prep in areas adjacent to PVA and air. For the volunteer study, the short-axis plane was imaged using the PC TI prep to compare T1 values in the myocardium of the septal and lateral walls. The T1 value of the phantom using the IR-FSE was not significantly different in the area between PVA and air, whereas the T1 value using the PC TI prep in the air area was significantly lower than that in the PVA area. T1 mapping of the healthy myocardium exhibited no significant difference between the septal and lateral walls. The T1 value using the PC TI prep in the air area was 6.3% lower than that using IR-FSE. In this study, T1 mapping using the PC TI prep exhibited high uniformity of T1 values.
Collapse
Affiliation(s)
- Hideaki Takasumi
- Department of Radiology, Fukushima Medical University Hospital, Fukushima, Japan.
| | - Shinya Seino
- Department of Radiology, Fukushima Medical University Hospital, Fukushima, Japan
| | - Katsuyuki Kikori
- Department of Radiology, Fukushima Medical University Hospital, Fukushima, Japan
| | - Hironobu Ishikawa
- Department of Radiology, Fukushima Medical University Hospital, Fukushima, Japan
| | - Takashi Kanezawa
- Department of Radiology, Fukushima Medical University Hospital, Fukushima, Japan
| | - Shuhei Bannae
- Healthcare IT Software Development Department, Healthcare IT Development Center, Healthcare IT Division, Canon Medical Systems Corporation, Tochigi, Japan
| | - Shigehide Kuhara
- Department of Medical Radiological Technology, Faculty of Health Sciences, Kyorin University, Tokyo, Japan
| | - Kunio Doi
- Department of Radiology, The University of Chicago, Chicago, IL, USA.,Gunma Prefectural College of Health Sciences, Gunma, Japan
| |
Collapse
|
6
|
Huang L, Neji R, Nazir MS, Whitaker J, Duong P, Reid F, Bosio F, Chiribiri A, Razavi R, Roujol S. FASt single-breathhold 2D multislice myocardial T 1 mapping (FAST1) at 1.5T for full left ventricular coverage in three breathholds. J Magn Reson Imaging 2019; 51:492-504. [PMID: 31342614 PMCID: PMC6954880 DOI: 10.1002/jmri.26869] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Accepted: 07/02/2019] [Indexed: 12/28/2022] Open
Abstract
Background Conventional myocardial T1 mapping techniques such as modified Look–Locker inversion recovery (MOLLI) generate one T1 map per breathhold. T1 mapping with full left ventricular coverage may be desirable when spatial T1 variations are expected. This would require multiple breathholds, increasing patient discomfort and prolonging scan time. Purpose To develop and characterize a novel FASt single‐breathhold 2D multislice myocardial T1 mapping (FAST1) technique for full left ventricular coverage. Study Type Prospective. Population/Phantom Numerical simulation, agarose/NiCl2 phantom, 9 healthy volunteers, and 17 patients. Field Strength/Sequence 1.5T/FAST1. Assessment Two FAST1 approaches, FAST1‐BS and FAST1‐IR, were characterized and compared with standard 5‐(3)‐3 MOLLI in terms of accuracy, precision/spatial variability, and repeatability. Statistical Tests Kruskal‐Wallis, Wilcoxon signed rank tests, intraclass correlation coefficient analysis, analysis of variance, Student's t‐tests, Pearson correlation analysis, and Bland–Altman analysis. Results In simulation/phantom, FAST1‐BS, FAST1‐IR, and MOLLI had an accuracy (expressed as T1 error) of 0.2%/4%, 6%/9%, and 4%/7%, respectively, while FAST1‐BS and FAST1‐IR had a precision penalty of 1.7/1.5 and 1.5/1.4 in comparison with MOLLI, respectively. In healthy volunteers, FAST1‐BS/FAST1‐IR/MOLLI led to different native myocardial T1 times (1016 ± 27 msec/952 ±22 msec/987 ± 23 msec, P < 0.0001) and spatial variability (66 ± 10 msec/57 ± 8 msec/46 ± 7 msec, P < 0.001). There were no statistically significant differences between all techniques for T1 repeatability (P = 0.18). In vivo native and postcontrast myocardial T1 times in both healthy volunteers and patients using FAST1‐BS/FAST1‐IR were highly correlated with MOLLI (Pearson correlation coefficient ≥0.93). Data Conclusion FAST1 enables myocardial T1 mapping with full left ventricular coverage in three separated breathholds. In comparison with MOLLI, FAST1 yield a 5‐fold increase of spatial coverage, limited penalty of T1 precision/spatial variability, no significant difference of T1 repeatability, and highly correlated T1 times. FAST1‐IR provides improved T1 precision/spatial variability but reduced accuracy when compared with FAST1‐BS. Level of Evidence: 1 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2020;51:492–504.
Collapse
Affiliation(s)
- Li Huang
- The School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Radhouene Neji
- The School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK.,MR Research Collaborations, Siemens Healthcare Limited, Frimley, UK
| | - Muhummad Sohaib Nazir
- The School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - John Whitaker
- The School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Phuoc Duong
- The School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Fiona Reid
- School of Population Health and Environmental Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Filippo Bosio
- The School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Amedeo Chiribiri
- The School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Reza Razavi
- The School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Sébastien Roujol
- The School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| |
Collapse
|
7
|
Jang J, Ngo LH, Captur G, Moon JC, Nezafat R. Measurement reproducibility of slice-interleaved T1 and T2 mapping sequences over 20 months: A single center study. PLoS One 2019; 14:e0220190. [PMID: 31344078 PMCID: PMC6658153 DOI: 10.1371/journal.pone.0220190] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2019] [Accepted: 07/10/2019] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Quantifying reproducibility of native T1 and T2 mapping over a long period (> 1 year) is necessary to assess whether changes in T1 and T2 over repeated sessions in a longitudinal study are associated with variability due to underlying tissue composition or technical confounders. OBJECTIVES To carry out a single-center phantom study to 1) investigate measurement reproducibility of slice-interleaved T1 (STONE) and T2 mapping over 20 months, 2) quantify sources of variability, and 3) compare reproducibility and measurements against reference spin-echo measurements. METHODS MR imaging was performed on a 1.5 Tesla Philips Achieva scanner every 2-3 weeks over 20 months using the T1MES phantom. In each session, slice-interleaved T1 and T2 mapping was repeated 3 times for 5 slices, and maps were reconstructed using both 2-parameter and 3-parameter fit models. Reproducibility between sessions, and repeatability between repetitions and slices were evaluated using coefficients of variation (CV). Different sources of variability were quantified using variance decomposition analysis. The slice-interleaved measurement was compared to the spin-echo reference and MOLLI. RESULTS Slice-interleaved T1 had excellent reproducibility and repeatability with a CV < 2%. The main sources of T1 variability were temperature in 2-parameter maps, and slice in 3-parameter maps. Superior between-session reproducibility to the spin-echo T1 was shown in 2-parameter maps, and similar reproducibility in 3-parameter maps. Superior reproducibility to MOLLI T1 was also shown. Similar measurements to the spin-echo T1 were observed with linear regression slopes of 0.94-0.99, but slight underestimation. Slice-interleaved T2 showed good reproducibility and repeatability with a CV < 7%. The main source of T2 variability was slice location/orientation. Between-session reproducibility was lower than the spin-echo T2 reference and showed good measurement agreement with linear regression slopes of 0.78-1.06. CONCLUSIONS Slice-interleaved T1 and T2 mapping sequences yield excellent long-term reproducibility over 20 months.
Collapse
Affiliation(s)
- Jihye Jang
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, United States of America
- Department of Computer Science, Technical University of Munich, Munich, Germany
| | - Long H. Ngo
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, United States of America
- Department of Biostatistics, Harvard T.H. Chan School of Public Health, Boston, MA, United States of America
| | - Gabriella Captur
- Barts Heart Center, The Cardiovascular Magnetic Resonance Imaging Unit, St Bartholomew’s Hospital, West Smithfield, London, United Kingdom
- NIHR University College London Hospitals Biomedical Research Center, London, United Kingdom
- UCL Institute of Cardiovascular Science, University College London, London, United Kingdom
| | - James C. Moon
- Barts Heart Center, The Cardiovascular Magnetic Resonance Imaging Unit, St Bartholomew’s Hospital, West Smithfield, London, United Kingdom
- NIHR University College London Hospitals Biomedical Research Center, London, United Kingdom
- UCL Institute of Cardiovascular Science, University College London, London, United Kingdom
| | - Reza Nezafat
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, United States of America
| |
Collapse
|
8
|
Duan C, Zhu Y, Jang J, Rodriguez J, Neisius U, Fahmy AS, Nezafat R. Non-contrast myocardial infarct scar assessment using a hybrid native T 1 and magnetization transfer imaging sequence at 1.5T. Magn Reson Med 2018; 81:3192-3201. [PMID: 30565296 DOI: 10.1002/mrm.27636] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2018] [Revised: 11/19/2018] [Accepted: 11/20/2018] [Indexed: 12/17/2022]
Abstract
PURPOSE To develop a gadolinium-free cardiac MR technique that simultaneously exploits native T1 and magnetization transfer (MT) contrast for the imaging of myocardial infarction. METHODS A novel hybrid T one and magnetization transfer (HYTOM) method was developed based on the modified look-locker inversion recovery (MOLLI) sequence, with a train of MT-prep pulses placed before the balanced SSFP (bSSFP) readout pulses. Numerical simulations, based on Bloch-McConnell equations, were performed to investigate the effects of MT induced by (1) the bSSFP readout pulses, and (2) the MT-prep pulses, on the measured, "apparent," native T1 values. The HYTOM method was then tested on 8 healthy adult subjects, 6 patients, and a swine with prior myocardial infarction (MI). The resulting imaging contrast between normal myocardium and infarcted tissues was compared with that of MOLLI. Late gadolinium enhancement (LGE) images were also obtained for infarct assessment in patients and swine. RESULTS Numerical simulation and in vivo studies in healthy volunteers demonstrated that MT effects, resulting from on-resonance bSSFP excitation pulses and off-resonance MT-prep pulses, reduce the measured T1 in both MOLLI and HTYOM. In vivo studies in patients and swine showed that the HYTOM sequence can identify locations of MI, as seen on LGE. Furthermore, the HYTOM method yields higher myocardium-to-scar contrast than MOLLI (contrast-to-noise ratio: 7.33 ± 1.67 vs. 3.77 ± 0.66, P < 0.01). CONCLUSION The proposed HYTOM method simultaneously exploits native T1 and MT contrast and significantly boosts the imaging contrast for myocardial infarction.
Collapse
Affiliation(s)
- Chong Duan
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Yanjie Zhu
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts.,Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Jihye Jang
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts.,Department of Computer Science, Technical University of Munich, Munich, Germany
| | - Jennifer Rodriguez
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Ulf Neisius
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Ahmed S Fahmy
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Reza Nezafat
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
9
|
Nezafat M, Nakamori S, Basha TA, Fahmy AS, Hauser T, Botnar RM. Imaging sequence for joint myocardial T 1 mapping and fat/water separation. Magn Reson Med 2018; 81:486-494. [PMID: 30058096 PMCID: PMC6258274 DOI: 10.1002/mrm.27390] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2018] [Revised: 05/09/2018] [Accepted: 05/14/2018] [Indexed: 01/03/2023]
Abstract
Purpose To develop and evaluate an imaging sequence to simultaneously quantify the epicardial fat volume and myocardial T1 relaxation time. Methods We introduced a novel simultaneous myocardial T1 mapping and fat/water separation sequence (joint T1‐fat/water separation). Dixon reconstruction is performed on a dual‐echo data set to generate water/fat images. T1 maps are computed using the water images, whereas the epicardial fat volume is calculated from the fat images. A phantom experiment using vials with different T1/T2 values and a bottle of oil was performed. Additional phantom experiment using vials of mixed fat/water was performed to show the potential of this sequence to mitigate the effect of intravoxel fat on estimated T1 maps. In vivo evaluation was performed in 17 subjects. Epicardial fat volume, native myocardial T1 measurements and precision were compared among slice‐interleaved T1 mapping, Dixon, and the proposed sequence. Results In the first phantom, the proposed sequence separated oil from water vials and there were no differences in T1 of the fat‐free vials (P = .1). In the second phantom, the T1 error decreased from 22%, 36%, 57%, and 73% to 8%, 9%, 16%, and 26%, respectively. In vivo there was no difference between myocardial T1 values (1067 ± 17 ms versus 1077 ± 24 ms, P = .6). The epicardial fat volume was similar for both sequences (54.3 ± 33 cm3 versus 52.4 ± 32 cm3, P = .8). Conclusion The proposed sequence provides simultaneous quantification of native myocardial T1 and epicardial fat volume. This will eliminate the need for an additional sequence in the cardiac imaging protocol if both measurements are clinically indicated.
Collapse
Affiliation(s)
- Maryam Nezafat
- Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom.,Department of Medicine, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Shiro Nakamori
- Department of Medicine, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Tamer A Basha
- Biomedical Engineering Department, Cairo University, Giza, Egypt
| | - Ahmed S Fahmy
- Department of Medicine, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - Thomas Hauser
- Department of Medicine, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts
| | - René M Botnar
- Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom.,Pontificia Universidad Católica de Chile, Escuela de Ingeniería, Santiago, Chile
| |
Collapse
|
10
|
Weingärtner S, Moeller S, Schmitter S, Auerbach E, Kellman P, Shenoy C, Akçakaya M. Simultaneous multislice imaging for native myocardial T 1 mapping: Improved spatial coverage in a single breath-hold. Magn Reson Med 2017; 78:462-471. [PMID: 28580583 PMCID: PMC5509494 DOI: 10.1002/mrm.26770] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2016] [Revised: 04/10/2017] [Accepted: 05/06/2017] [Indexed: 01/02/2023]
Abstract
PURPOSE To develop a saturation recovery myocardial T1 mapping method for the simultaneous multislice acquisition of three slices. METHODS Saturation pulse-prepared heart rate independent inversion recovery (SAPPHIRE) T1 mapping was implemented with simultaneous multislice imaging using FLASH readouts for faster coverage of the myocardium. Controlled aliasing in parallel imaging (CAIPI) was used to achieve minimal noise amplification in three slices. Multiband reconstruction was performed using three linear reconstruction methods: Slice- and in-plane GRAPPA, CG-SENSE, and Tikhonov-regularized CG-SENSE. Accuracy, spatial variability, and interslice leakage were compared with single-band T1 mapping in a phantom and in six healthy subjects. RESULTS Multiband phantom T1 times showed good agreement with single-band T1 mapping for all three reconstruction methods (normalized root mean square error <1.0%). The increase in spatial variability compared with single-band imaging was lowest for GRAPPA (1.29-fold), with higher penalties for Tikhonov-regularized CG-SENSE (1.47-fold) and CG-SENSE (1.52-fold). In vivo multiband T1 times showed no significant difference compared with single-band (T1 time ± intersegmental variability: single-band, 1580 ± 119 ms; GRAPPA, 1572 ± 145 ms; CG-SENSE, 1579 ± 159 ms; Tikhonov, 1586 ± 150 ms [analysis of variance; P = 0.86]). Interslice leakage was smallest for GRAPPA (5.4%) and higher for CG-SENSE (6.2%) and Tikhonov-regularized CG-SENSE (7.9%). CONCLUSION Multiband accelerated myocardial T1 mapping demonstrated the potential for single-breath-hold T1 quantification in 16 American Heart Association segments over three slices. A 1.2- to 1.4-fold higher in vivo spatial variability was observed, where GRAPPA-based reconstruction showed the highest homogeneity and the least interslice leakage. Magn Reson Med 78:462-471, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Sebastian Weingärtner
- Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, United States
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, United States
- Computer Assisted Clinical Medicine, University Medical Center Mannheim, Heidelberg University, Mannheim, Germany
| | - Steen Moeller
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, United States
| | - Sebastian Schmitter
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, United States
- Medical Physics and Metrological Information Technology, Physikalisch-Technische Bundesanstalt, Berlin, Germany
| | - Edward Auerbach
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, United States
| | - Peter Kellman
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, United States
| | - Chetan Shenoy
- Cardiovascular Division, Department of Medicine, University of Minnesota, Minneapolis, MN, United States
| | - Mehmet Akçakaya
- Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, United States
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, United States
| |
Collapse
|