1
|
Yang S, Bekö G, Wargocki P, Zhang M, Merizak M, Nenes A, Williams J, Licina D. Physiology or Psychology: What Drives Human Emissions of Carbon Dioxide and Ammonia? ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:1986-1997. [PMID: 38237915 PMCID: PMC10832055 DOI: 10.1021/acs.est.3c07659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2023] [Revised: 11/26/2023] [Accepted: 12/20/2023] [Indexed: 01/31/2024]
Abstract
Humans are the primary sources of CO2 and NH3 indoors. Their emission rates may be influenced by human physiological and psychological status. This study investigated the impact of physiological and psychological engagements on the human emissions of CO2 and NH3. In a climate chamber, we measured CO2 and NH3 emissions from participants performing physical activities (walking and running at metabolic rates of 2.5 and 5 met, respectively) and psychological stimuli (meditation and cognitive tasks). Participants' physiological responses were recorded, including the skin temperature, electrodermal activity (EDA), and heart rate, and then analyzed for their relationship with CO2 and NH3 emissions. The results showed that physiological engagement considerably elevated per-person CO2 emission rates from 19.6 (seated) to 46.9 (2.5 met) and 115.4 L/h (5 met) and NH3 emission rates from 2.7 to 5.1 and 8.3 mg/h, respectively. CO2 emissions reduced when participants stopped running, whereas NH3 emissions continued to increase owing to their distinct emission mechanisms. Psychological engagement did not significantly alter participants' emissions of CO2 and NH3. Regression analysis revealed that CO2 emissions were predominantly correlated with heart rate, whereas NH3 emissions were mainly associated with skin temperature and EDA. These findings contribute to a deeper understanding of human metabolic emissions of CO2 and NH3.
Collapse
Affiliation(s)
- Shen Yang
- Human-Oriented
Built Environment Lab, School of Architecture, Civil and Environmental
Engineering, École Polytechnique
Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland
| | - Gabriel Bekö
- International
Centre for Indoor Environment and Energy, Department of Environmental
and Resource Engineering, Technical University
of Denmark, Kongens Lyngby, 2800 Copenhagen, Denmark
| | - Pawel Wargocki
- International
Centre for Indoor Environment and Energy, Department of Environmental
and Resource Engineering, Technical University
of Denmark, Kongens Lyngby, 2800 Copenhagen, Denmark
| | - Meixia Zhang
- Human-Oriented
Built Environment Lab, School of Architecture, Civil and Environmental
Engineering, École Polytechnique
Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland
| | - Marouane Merizak
- Human-Oriented
Built Environment Lab, School of Architecture, Civil and Environmental
Engineering, École Polytechnique
Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland
| | - Athanasios Nenes
- Laboratory
of Atmospheric Processes and Their Impacts, School of Architecture,
Civil & Environmental Engineering, École
Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland
| | - Jonathan Williams
- Max
Planck Institute for Chemistry, Hahn-Meitner Weg 1, 55128 Mainz, Germany
- Energy,
Environment and Water Research Center, The
Cyprus Institute, 2121 Nicosia, Cyprus
| | - Dusan Licina
- Human-Oriented
Built Environment Lab, School of Architecture, Civil and Environmental
Engineering, École Polytechnique
Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland
| |
Collapse
|
2
|
Khokhar M. Non-invasive detection of renal disease biomarkers through breath analysis. J Breath Res 2024; 18:024001. [PMID: 38099568 DOI: 10.1088/1752-7163/ad15fb] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Accepted: 12/14/2023] [Indexed: 01/06/2024]
Abstract
Breath biomarkers are substances found in exhaled breath that can be used for non-invasive diagnosis and monitoring of medical conditions, including kidney disease. Detection techniques include mass spectrometry (MS), gas chromatography (GC), and electrochemical sensors. Biosensors, such as GC-MS or electronic nose (e-nose) devices, can be used to detect volatile organic compounds (VOCs) in exhaled breath associated with metabolic changes in the body, including the kidneys. E-nose devices could provide an early indication of potential kidney problems through the detection of VOCs associated with kidney dysfunction. This review discusses the sources of breath biomarkers for monitoring renal disease during dialysis and different biosensor approaches for detecting exhaled breath biomarkers. The future of using various types of biosensor-based real-time breathing diagnosis for renal failure is also discussed.
Collapse
Affiliation(s)
- Manoj Khokhar
- Department of Biochemistry, All India Institute of Medical Sciences, Jodhpur, Rajasthan, India
| |
Collapse
|
3
|
Sharma A, Kumar R, Varadwaj P. Smelling the Disease: Diagnostic Potential of Breath Analysis. Mol Diagn Ther 2023; 27:321-347. [PMID: 36729362 PMCID: PMC9893210 DOI: 10.1007/s40291-023-00640-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/11/2023] [Indexed: 02/03/2023]
Abstract
Breath analysis is a relatively recent field of research with much promise in scientific and clinical studies. Breath contains endogenously produced volatile organic components (VOCs) resulting from metabolites of ingested precursors, gut and air-passage bacteria, environmental contacts, etc. Numerous recent studies have suggested changes in breath composition during the course of many diseases, and breath analysis may lead to the diagnosis of such diseases. Therefore, it is important to identify the disease-specific variations in the concentration of breath to diagnose the diseases. In this review, we explore methods that are used to detect VOCs in laboratory settings, VOC constituents in exhaled air and other body fluids (e.g., sweat, saliva, skin, urine, blood, fecal matter, vaginal secretions, etc.), VOC identification in various diseases, and recently developed electronic (E)-nose-based sensors to detect VOCs. Identifying such VOCs and applying them as disease-specific biomarkers to obtain accurate, reproducible, and fast disease diagnosis could serve as an alternative to traditional invasive diagnosis methods. However, the success of VOC-based identification of diseases is limited to laboratory settings. Large-scale clinical data are warranted for establishing the robustness of disease diagnosis. Also, to identify specific VOCs associated with illness states, extensive clinical trials must be performed using both analytical instruments and electronic noses equipped with stable and precise sensors.
Collapse
Affiliation(s)
- Anju Sharma
- Systems Biology Lab, Indian Institute of Information Technology, Allahabad, Uttar Pradesh, India
| | - Rajnish Kumar
- Amity Institute of Biotechnology, Amity University Uttar Pradesh, Uttar Pradesh, Lucknow Campus, Lucknow, India
| | - Pritish Varadwaj
- Systems Biology Lab, Indian Institute of Information Technology, Allahabad, Uttar Pradesh, India.
| |
Collapse
|
4
|
Smith D, Španěl P, Demarais N, Langford VS, McEwan MJ. Recent developments and applications of selected ion flow tube mass spectrometry (SIFT-MS). MASS SPECTROMETRY REVIEWS 2023:e21835. [PMID: 36776107 DOI: 10.1002/mas.21835] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 10/09/2022] [Accepted: 12/12/2022] [Indexed: 06/18/2023]
Abstract
Selected ion flow tube mass spectrometry (SIFT-MS) is now recognized as the most versatile analytical technique for the identification and quantification of trace gases down to the parts-per-trillion by volume, pptv, range. This statement is supported by the wide reach of its applications, from real-time analysis, obviating sample collection of very humid exhaled breath, to its adoption in industrial scenarios for air quality monitoring. This review touches on the recent extensions to the underpinning ion chemistry kinetics library and the alternative challenge of using nitrogen carrier gas instead of helium. The addition of reagent anions in the Voice200 series of SIFT-MS instruments has enhanced the analytical capability, thus allowing analyses of volatile trace compounds in humid air that cannot be analyzed using reagent cations alone, as clarified by outlining the anion chemistry involved. Case studies are reviewed of breath analysis and bacterial culture volatile organic compound (VOC), emissions, environmental applications such as air, water, and soil analysis, workplace safety such as transport container fumigants, airborne contamination in semiconductor fabrication, food flavor and spoilage, drugs contamination and VOC emissions from packaging to demonstrate the stated qualities and uniqueness of the new generation SIFT-MS instrumentation. Finally, some advancements that can be made to improve the analytical capability and reach of SIFT-MS are mentioned.
Collapse
Affiliation(s)
- David Smith
- J. Heyrovský Institute of Physical Chemistry, Czech Academy of Sciences, Prague, Czechia
| | - Patrik Španěl
- J. Heyrovský Institute of Physical Chemistry, Czech Academy of Sciences, Prague, Czechia
| | | | | | - Murray J McEwan
- Syft Technologies Limited, Christchurch, New Zealand
- Department of Chemistry, University of Canterbury, Christchurch, New Zealand
| |
Collapse
|
5
|
Pu D, Shan Y, Wang J, Sun B, Xu Y, Zhang W, Zhang Y. Recent trends in aroma release and perception during food oral processing: A review. Crit Rev Food Sci Nutr 2022; 64:3441-3457. [PMID: 36218375 DOI: 10.1080/10408398.2022.2132209] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
The dynamic and complex peculiarities of the oral environment present several challenges for controlling the aroma release during food consumption. They also pose higher requirements for designing food with better sensory quality. This requires a comprehensive understanding of the basic rules of aroma transmission and aroma perception during food oral processing and its behind mechanism. This review summarized the latest developments in aroma release from food to retronasal cavity, aroma release and delivery influencing factors, aroma perception mechanisms. The individual variance is the most important factor affecting aroma release and perception. Therefore, the intelligent chewing simulator is the key to establish a standard analytical method. The key odorants perceived from the retronasal cavity should be given more attention during food oral processing. Identification of the olfactory receptor activated by specific odorants and its binding mechanisms are still the bottleneck. Electrophysiology and image technology are the new noninvasive technologies in elucidating the brain signals among multisensory, which can fill the gap between aroma perception and other senses. Moreover, it is necessary to develop a new approach to integrate the relationship among aroma binding parameters, aroma concentration, aroma attributes and cross-modal reactions to make the aroma prediction model more accurate.
Collapse
Affiliation(s)
- Dandan Pu
- Beijing Key Laboratory of Flavor Chemistry, Beijing Technology and Business University (BTBU), Beijing, China
| | - Yimeng Shan
- Beijing Key Laboratory of Flavor Chemistry, Beijing Technology and Business University (BTBU), Beijing, China
| | - Juan Wang
- Beijing Key Laboratory of Flavor Chemistry, Beijing Technology and Business University (BTBU), Beijing, China
| | - Baoguo Sun
- Beijing Key Laboratory of Flavor Chemistry, Beijing Technology and Business University (BTBU), Beijing, China
| | - Youqiang Xu
- Beijing Key Laboratory of Flavor Chemistry, Beijing Technology and Business University (BTBU), Beijing, China
| | - Wangang Zhang
- College of Food Science and Technology, Nanjing Agricultural University, Nanjing, Jiangsu, China
| | - Yuyu Zhang
- Beijing Key Laboratory of Flavor Chemistry, Beijing Technology and Business University (BTBU), Beijing, China
| |
Collapse
|
6
|
Virtanen J, Anttalainen A, Ormiskangas J, Karjalainen M, Kontunen A, Rautiainen M, Oksala N, Kivekäs I, Roine A. Differentiation of aspirated nasal air from room air using analysis with a differential mobility spectrometry-based electronic nose: a proof-of-concept study. J Breath Res 2021; 16. [PMID: 34794137 DOI: 10.1088/1752-7163/ac3b39] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Accepted: 11/18/2021] [Indexed: 12/17/2022]
Abstract
Over the last few decades, breath analysis using electronic nose (eNose) technology has become a topic of intense research, as it is both non-invasive and painless, and is suitable for point-of-care use. To date, however, only a few studies have examined nasal air. As the air in the oral cavity and the lungs differs from the air in the nasal cavity, it is unknown whether aspirated nasal air could be exploited with eNose technology. Compared to traditional eNoses, differential mobility spectrometry uses an alternating electrical field to discriminate the different molecules of gas mixtures, providing analogous information. This study reports the collection of nasal air by aspiration and the subsequent analysis of the collected air using a differential mobility spectrometer. We collected nasal air from ten volunteers into breath collecting bags and compared them to bags of room air and the air aspirated through the device. Distance and dissimilarity metrics between the sample types were calculated and statistical significance evaluated with Kolmogorov-Smirnov test. After leave-one-day-out cross-validation, a shrinkage linear discriminant classifier was able to correctly classify 100% of the samples. The nasal air differed (p< 0.05) from the other sample types. The results show the feasibility of collecting nasal air by aspiration and subsequent analysis using differential mobility spectrometry, and thus increases the potential of the method to be used in disease detection studies.
Collapse
Affiliation(s)
- Jussi Virtanen
- Department of Otorhinolaryngology, Head and Neck Surgery, Tampere University Hospital, Tampere, Finland.,Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | | | - Jaakko Ormiskangas
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.,Faculty of Engineering and Natural Sciences, Automation Technology and Mechanical Engineering Unit, Tampere University, Tampere, Finland
| | - Markus Karjalainen
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.,Olfactomics Ltd, Tampere, Finland
| | - Anton Kontunen
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.,Olfactomics Ltd, Tampere, Finland
| | - Markus Rautiainen
- Department of Otorhinolaryngology, Head and Neck Surgery, Tampere University Hospital, Tampere, Finland.,Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Niku Oksala
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.,Olfactomics Ltd, Tampere, Finland.,Vascular Centre, Tampere University Hospital, Tampere, Finland
| | - Ilkka Kivekäs
- Department of Otorhinolaryngology, Head and Neck Surgery, Tampere University Hospital, Tampere, Finland.,Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Antti Roine
- Olfactomics Ltd, Tampere, Finland.,Department of Surgery, Tampere University Hospital, Hatanpää Hospital, Tampere, Finland
| |
Collapse
|
7
|
Ammonia Gas Sensors: Comparison of Solid-State and Optical Methods. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10155111] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
High precision and fast measurement of gas concentrations is important for both understanding and monitoring various phenomena, from industrial and environmental to medical and scientific applications. This article deals with the recent progress in ammonia detection using in-situ solid-state and optical methods. Due to the continuous progress in material engineering and optoelectronic technologies, these methods are among the most perceptive because of their advantages in a specific application. We present the basics of each technique, their performance limits, and the possibility of further development. The practical implementations of representative examples are described in detail. Finally, we present a performance comparison of selected practical application, accumulating data reported over the preceding decade, and conclude from this comparison.
Collapse
|
8
|
Selvaraj R, Vasa NJ, Nagendra SMS, Mizaikoff B. Advances in Mid-Infrared Spectroscopy-Based Sensing Techniques for Exhaled Breath Diagnostics. Molecules 2020; 25:molecules25092227. [PMID: 32397389 PMCID: PMC7249025 DOI: 10.3390/molecules25092227] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Revised: 04/28/2020] [Accepted: 04/29/2020] [Indexed: 01/05/2023] Open
Abstract
Human exhaled breath consists of more than 3000 volatile organic compounds, many of which are relevant biomarkers for various diseases. Although gas chromatography has been the gold standard for volatile organic compound (VOC) detection in exhaled breath, recent developments in mid-infrared (MIR) laser spectroscopy have led to the promise of compact point-of-care (POC) optical instruments enabling even single breath diagnostics. In this review, we discuss the evolution of MIR sensing technologies with a special focus on photoacoustic spectroscopy, and its application in exhaled breath biomarker detection. While mid-infrared point-of-care instrumentation promises high sensitivity and inherent molecular selectivity, the lack of standardization of the various techniques has to be overcome for translating these techniques into more widespread real-time clinical use.
Collapse
Affiliation(s)
- Ramya Selvaraj
- Department of Engineering Design, Indian Institute of Technology Madras, Chennai 600036, India;
- Correspondence:
| | - Nilesh J. Vasa
- Department of Engineering Design, Indian Institute of Technology Madras, Chennai 600036, India;
| | - S. M. Shiva Nagendra
- Department of Civil Engineering, Indian Institute of Technology Madras, Chennai 600036, India;
| | - Boris Mizaikoff
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, 89081 Ulm, Germany;
| |
Collapse
|
9
|
Li M, Weschler CJ, Bekö G, Wargocki P, Lucic G, Williams J. Human Ammonia Emission Rates under Various Indoor Environmental Conditions. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2020; 54:5419-5428. [PMID: 32233434 DOI: 10.1021/acs.est.0c00094] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Ammonia (NH3) is typically present at higher concentrations in indoor air (∼10-70 ppb) than in outdoor air (∼50 ppt to 5 ppb). It is the dominant neutralizer of acidic species in indoor environments, strongly influencing the partitioning of gaseous acidic and basic species to aerosols, surface films, and bulk water. We have measured NH3 emissions from humans in an environmentally controlled chamber. A series of experiments, each with four volunteers, quantified NH3 emissions as a function of temperature (25.1-32.6 °C), clothing (long-sleeved shirts/pants or T-shirts/shorts), age (teenagers, adults, and seniors), relative humidity (low or high), and ozone (<2 ppb or ∼35 ppb). Higher temperature and more skin exposure (T-shirts/shorts) significantly increased emission rates. For adults and seniors (long clothing), NH3 emissions are estimated to be 0.4 mg h-1 person-1 at 25 °C, 0.8 mg h-1 person-1 at 27 °C, and 1.4 mg h-1 person-1 at 29 °C, based on the temperature relationship observed in this study. Human NH3 emissions are sufficient to neutralize the acidifying impacts of human CO2 emissions. Results from this study can be used to more accurately model indoor and inner-city outdoor NH3 concentrations and associated chemistry.
Collapse
Affiliation(s)
- Mengze Li
- Max Planck Institute for Chemistry, Hahn-Meitner Weg 1, 55128 Mainz, Germany
| | - Charles J Weschler
- International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Lyngby 2800, Denmark
- Environmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, New Jersey 08854, United States
| | - Gabriel Bekö
- International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Lyngby 2800, Denmark
| | - Pawel Wargocki
- International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Lyngby 2800, Denmark
| | - Gregor Lucic
- Picarro Inc., 3105 Patrick Henry Drive, Santa Clara, California 95054, United States
| | - Jonathan Williams
- Max Planck Institute for Chemistry, Hahn-Meitner Weg 1, 55128 Mainz, Germany
| |
Collapse
|
10
|
Chen CC, Hsieh JC, Chao CH, Yang WS, Cheng HT, Chan CK, Lu CJ, Meng HF, Zan HW. Correlation between breath ammonia and blood urea nitrogen levels in chronic kidney disease and dialysis patients. J Breath Res 2020; 14:036002. [DOI: 10.1088/1752-7163/ab728b] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
11
|
Roslund K, Lehto M, Pussinen P, Groop PH, Halonen L, Metsälä M. On-line profiling of volatile compounds produced in vitro by pathogenic oral bacteria. J Breath Res 2019; 14:016010. [PMID: 31698353 DOI: 10.1088/1752-7163/ab5559] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Infections by oral pathogens are one of the most common health problems worldwide. Due to the intimate connection between exhaled breath and the oral cavity, breath analysis could potentially be used to diagnose these infections. However, little is known about the volatile emissions of important oral pathogens that are connected with gingivitis and periodontitis. In this study, we have performed in vitro headspace measurements on four important oral pathogens (P. gingivalis, T. forsythia, P. intermedia and P. nigrescens) using proton transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS). Some of the most abundant compounds produced by the bacteria include hydrogen sulphide, methanethiol, acetone, dimethylsulphide, isoprene, cyclopentanone and indole as tentatively assigned from the mass spectra. Several other abundant mass signals were recorded but the assignment of these is less certain. Some of the bacterial species can be separated from each other by the emitted volatile fingerprints. The results of this study can be used in potential development of a diagnostic breath test for oral infections. In addition, as several of the measured compounds are known to be toxic, the results point to an intriguing possibility of studying the connection between the bacterial virulence and the emitted volatile compounds.
Collapse
Affiliation(s)
- Kajsa Roslund
- Department of Chemistry, University of Helsinki, Helsinki, Finland
| | | | | | | | | | | |
Collapse
|
12
|
Application of Near-Infrared Optical Feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) to the Detection of Ammonia in Exhaled Human Breath. SENSORS 2019; 19:s19173686. [PMID: 31450646 PMCID: PMC6749448 DOI: 10.3390/s19173686] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Revised: 08/17/2019] [Accepted: 08/22/2019] [Indexed: 11/23/2022]
Abstract
The qualitative and quantitative analysis to trace gas in exhaled human breath has become a promising technique in biomedical applications such as disease diagnosis and health status monitoring. This paper describes an application of a high spectral resolution optical feedback cavity enhanced absorption spectroscopy (OF-CEAS) for ammonia detection in exhaled human breath, and the main interference of gases such as CO2 and H2O are approximately eliminated at the same time. With appropriate optical feedback, a fibered distributed feedback (DFB) diode laser emitting at 1531.6 nm is locked to the resonance of a V-shaped cavity with a free spectral range (FSR) of 300 MHz and a finesse of 14,610. A minimum detectable absorption coefficient of αmin = 2.3 × 10−9 cm−1 is achieved in a single scan within 5 s, yielding a detection limit of 17 ppb for NH3 in breath gas at low pressure, and this stable system allows the detection limit down to 4.5 ppb when the spectra to be averaged over 16 laser scans. Different from typical CEAS with a static cavity, which is limited by the FSR in frequency space, the attainable spectral resolution of our experimental setup can be up to 0.002 cm−1 owing to the simultaneous laser frequency tuning and cavity dither. Hence, the absorption line profile is more accurate, which is most suitable for low-pressure trace gas detection. This work has great potential for accurate selectivity and high sensitivity applications in human breath analysis and atmosphere sciences.
Collapse
|
13
|
Germanese D, Colantonio S, D'Acunto M, Romagnoli V, Salvati A, Brunetto M. An E-Nose for the Monitoring of Severe Liver Impairment: A Preliminary Study. SENSORS 2019; 19:s19173656. [PMID: 31443499 PMCID: PMC6749560 DOI: 10.3390/s19173656] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/27/2019] [Revised: 07/25/2019] [Accepted: 08/09/2019] [Indexed: 11/16/2022]
Abstract
Biologically inspired to mammalian olfactory system, electronic noses became popular during the last three decades. In literature, as well as in daily practice, a wide range of applications are reported. Nevertheless, the most pioneering one has been (and still is) the assessment of the human breath composition. In this study, we used a prototype of electronic nose, called Wize Sniffer (WS) and based it on an array of semiconductor gas sensor, to detect ammonia in the breath of patients suffering from severe liver impairment. In the setting of severely impaired liver, toxic substances, such as ammonia, accumulate in the systemic circulation and in the brain. This may result in Hepatic Encephalopathy (HE), a spectrum of neuro-psychiatric abnormalities which include changes in cognitive functions, consciousness, and behaviour. HE can be detected only by specific but time-consuming and burdensome examinations, such as blood ammonia levels assessment and neuro-psychological tests. In the presented proof-of-concept study, we aimed at investigating the possibility of discriminating the severity degree of liver impairment on the basis of the detected breath ammonia, in view of the detection of HE at its early stage.
Collapse
Affiliation(s)
- Danila Germanese
- Institute of Information Science and Technology (ISTI), National Research Council (CNR), 56127 Pisa, Italy.
| | - Sara Colantonio
- Institute of Information Science and Technology (ISTI), National Research Council (CNR), 56127 Pisa, Italy
| | - Mario D'Acunto
- Institute of Biophysics (IBF), National Research Council (CNR), 56127 Pisa, Italy
| | - Veronica Romagnoli
- Gastroenterology and Hepatology Unit, University Hospital of Pisa, 56127 Pisa, Italy
| | - Antonio Salvati
- Gastroenterology and Hepatology Unit, University Hospital of Pisa, 56127 Pisa, Italy
| | - Maurizia Brunetto
- Gastroenterology and Hepatology Unit, University Hospital of Pisa, 56127 Pisa, Italy
| |
Collapse
|
14
|
Bruderer T, Gaisl T, Gaugg MT, Nowak N, Streckenbach B, Müller S, Moeller A, Kohler M, Zenobi R. On-Line Analysis of Exhaled Breath Focus Review. Chem Rev 2019; 119:10803-10828. [PMID: 31594311 DOI: 10.1021/acs.chemrev.9b00005] [Citation(s) in RCA: 116] [Impact Index Per Article: 23.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
On-line analysis of exhaled breath offers insight into a person's metabolism without the need for sample preparation or sample collection. Due to its noninvasive nature and the possibility to sample continuously, the analysis of breath has great clinical potential. The unique features of this technology make it an attractive candidate for applications in medicine, beyond the task of diagnosis. We review the current methodologies for on-line breath analysis, discuss current and future applications, and critically evaluate challenges and pitfalls such as the need for standardization. Special emphasis is given to the use of the technology in diagnosing respiratory diseases, potential niche applications, and the promise of breath analysis for personalized medicine. The analytical methodologies used range from very small and low-cost chemical sensors, which are ideal for continuous monitoring of disease status, to optical spectroscopy and state-of-the-art, high-resolution mass spectrometry. The latter can be utilized for untargeted analysis of exhaled breath, with the capability to identify hitherto unknown molecules. The interpretation of the resulting big data sets is complex and often constrained due to a limited number of participants. Even larger data sets will be needed for assessing reproducibility and for validation of biomarker candidates. In addition, molecular structures and quantification of compounds are generally not easily available from on-line measurements and require complementary measurements, for example, a separation method coupled to mass spectrometry. Furthermore, a lack of standardization still hampers the application of the technique to screen larger cohorts of patients. This review summarizes the present status and continuous improvements of the principal on-line breath analysis methods and evaluates obstacles for their wider application.
Collapse
Affiliation(s)
- Tobias Bruderer
- Department of Chemistry and Applied Biosciences , Swiss Federal Institute of Technology , CH-8093 Zurich , Switzerland.,Division of Respiratory Medicine , University Children's Hospital Zurich and Children's Research Center Zurich , CH-8032 Zurich , Switzerland
| | - Thomas Gaisl
- Department of Pulmonology , University Hospital Zurich , CH-8091 Zurich , Switzerland.,Zurich Center for Interdisciplinary Sleep Research , University of Zurich , CH-8091 Zurich , Switzerland
| | - Martin T Gaugg
- Department of Chemistry and Applied Biosciences , Swiss Federal Institute of Technology , CH-8093 Zurich , Switzerland
| | - Nora Nowak
- Department of Chemistry and Applied Biosciences , Swiss Federal Institute of Technology , CH-8093 Zurich , Switzerland
| | - Bettina Streckenbach
- Department of Chemistry and Applied Biosciences , Swiss Federal Institute of Technology , CH-8093 Zurich , Switzerland
| | - Simona Müller
- Department of Chemistry and Applied Biosciences , Swiss Federal Institute of Technology , CH-8093 Zurich , Switzerland
| | - Alexander Moeller
- Division of Respiratory Medicine , University Children's Hospital Zurich and Children's Research Center Zurich , CH-8032 Zurich , Switzerland
| | - Malcolm Kohler
- Department of Pulmonology , University Hospital Zurich , CH-8091 Zurich , Switzerland.,Center for Integrative Human Physiology , University of Zurich , CH-8091 Zurich , Switzerland.,Zurich Center for Interdisciplinary Sleep Research , University of Zurich , CH-8091 Zurich , Switzerland
| | - Renato Zenobi
- Department of Chemistry and Applied Biosciences , Swiss Federal Institute of Technology , CH-8093 Zurich , Switzerland
| |
Collapse
|
15
|
Güntner AT, Abegg S, Königstein K, Gerber PA, Schmidt-Trucksäss A, Pratsinis SE. Breath Sensors for Health Monitoring. ACS Sens 2019; 4:268-280. [PMID: 30623644 DOI: 10.1021/acssensors.8b00937] [Citation(s) in RCA: 111] [Impact Index Per Article: 22.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Breath sensors can revolutionize medical diagnostics by on-demand detection and monitoring of health parameters in a noninvasive and personalized fashion. Despite extensive research for more than two decades, however, only a few breath sensors have been translated into clinical practice. Actually, most never even left the scientific laboratories. Here, we describe key challenges that currently impede realization of breath sensors and highlight strategies to overcome them. Specifically, we start with breath marker selection (with emphasis on metabolic and inflammatory markers) and breath sampling. Next, the sensitivity, stability, and selectivity requirements for breath sensors are described. Concepts are elaborated to systematically address these requirements by material design (focusing on chemoresistive metal oxides), orthogonal arrays, and filters. Finally, aspects of portable device integration, user communication, and clinical applicability are discussed.
Collapse
Affiliation(s)
- Andreas T. Güntner
- Particle Technology Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, CH-8092 Zurich, Switzerland
- Department of Endocrinology, Diabetes, and Clinical Nutrition, University Hospital Zurich, CH-8091 Zurich, Switzerland
| | - Sebastian Abegg
- Particle Technology Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, CH-8092 Zurich, Switzerland
| | - Karsten Königstein
- Division Sports and Exercise Medicine, Department of Sport, Exercise and Health, University of Basel, CH-4052 Basel, Switzerland
| | - Philipp A. Gerber
- Department of Endocrinology, Diabetes, and Clinical Nutrition, University Hospital Zurich, CH-8091 Zurich, Switzerland
| | - Arno Schmidt-Trucksäss
- Division Sports and Exercise Medicine, Department of Sport, Exercise and Health, University of Basel, CH-4052 Basel, Switzerland
| | - Sotiris E. Pratsinis
- Particle Technology Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, CH-8092 Zurich, Switzerland
| |
Collapse
|
16
|
Li X, Huang D, Zeng J, Chan CK, Zhou Z. Positive matrix factorization: A data preprocessing strategy for direct mass spectrometry-based breath analysis. Talanta 2018; 192:32-39. [PMID: 30348397 DOI: 10.1016/j.talanta.2018.09.020] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2018] [Revised: 08/20/2018] [Accepted: 09/08/2018] [Indexed: 12/27/2022]
Abstract
Interest in exhaled breath has grown considerably in recent years, as breath biosampling has shown promise for non-invasive disease diagnosis, therapeutic drug monitoring, and environmental exposure. Real time breath analysis can be accomplished via direct online mass spectrometry (MS)-based methods, which can provide more accurate and detailed data and an enhanced understanding of the temporal evolution of exhaled VOCs in the breath; however, the complicated chemical composition and large raw datasets involved in breath analysis have hindered the discovery of sources contributing to the exhaled VOCs. The positive matrix factorization (PMF) receptor model has been widely used for source apportionment in atmospheric studies. Since the exhaled VOCs contain compounds from various sources, such as alveolar air, mouth air and respiratory dead-space air, PMF may be also helpful for source apportionment of exhaled VOCs in the breath. Thus, this study explores the application of PMF in the pretreatment of direct breath measurement data. The results indicate that (i) endogenous compounds and background contaminants sources can be readily distinguished by PMF in data obtained from replicate measurements of human exhaled breath at single time points (~30 s/measurement), which may benefit both exhalome investigations and the identification of exposure biomarkers; (ii) sources resolved from online measurement data collected over longer periods (1.5 h) can be used to isolate the evolution of exhaled VOCs and investigate processes such as the pharmacokinetics of ketamine and its major metabolites. Therefore, PMF has shown promise for both data processing and subsequent data mining for the ambient MS-based breath analysis.
Collapse
Affiliation(s)
- Xue Li
- Institute of Mass Spectrometry and Atmospheric Environment, Jinan University, No. 601 Huangpu Avenue West, Guangzhou 510632, China; Atmospheric Pollution Online Source Analysis Engineering Research Center of Guangdong Province, Jinan University, Guangzhou 510632, China.
| | - Dandan Huang
- School of Energy and Environment, City University of Hong Kong, Hong Kong, China; State Environmental Protection Key Laboratory of the Cause and Prevention of Urban Air Pollution Complex, Shanghai 200233, China
| | - Jiafa Zeng
- Institute of Mass Spectrometry and Atmospheric Environment, Jinan University, No. 601 Huangpu Avenue West, Guangzhou 510632, China; Atmospheric Pollution Online Source Analysis Engineering Research Center of Guangdong Province, Jinan University, Guangzhou 510632, China
| | - Chak Keung Chan
- School of Energy and Environment, City University of Hong Kong, Hong Kong, China
| | - Zhen Zhou
- Institute of Mass Spectrometry and Atmospheric Environment, Jinan University, No. 601 Huangpu Avenue West, Guangzhou 510632, China; Atmospheric Pollution Online Source Analysis Engineering Research Center of Guangdong Province, Jinan University, Guangzhou 510632, China
| |
Collapse
|
17
|
Popa C, Bratu AM, Petrus M. A comparative photoacoustic study of multi gases from human respiration: mouth breathing vs. nasal breathing. Microchem J 2018. [DOI: 10.1016/j.microc.2018.02.030] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
18
|
Li X, Huang DD, Du R, Zhang ZJ, Chan CK, Huang ZX, Zhou Z. Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry. J Vis Exp 2018. [PMID: 29578507 DOI: 10.3791/56465] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
Exhaled volatile organic compounds (VOCs) have aroused considerable interest, since they can serve as biomarkers for disease diagnosis and environmental exposure in a non-invasive manner. In this work, we present a protocol to characterize the exhaled VOCs in real time by using secondary nanoelectrospray ionization coupled to high resolution mass spectrometry (Sec-nanoESI-HRMS). The homemade Sec-nanoESI source was readily set up based on a commercial nanoESI source. Hundreds of peaks were observed in the background-subtracted mass spectra of exhaled breath, and the mass accuracy values are -4.0-13.5 ppm and -20.3-1.3 ppm in the positive and negative ion detection modes, respectively. The peaks were assigned with accurate elemental composition according to the accurate mass and isotopic pattern. Less than 30 s is used for one exhalation measurement, and it takes approximately 7 min for six replicated measurements.
Collapse
Affiliation(s)
- Xue Li
- Institute of Mass Spectrometer and Atmospheric Environment, Jinan University; Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution;
| | - Dan D Huang
- School of Energy and Environment, City University of Hong Kong
| | - Rui Du
- Institute of Mass Spectrometer and Atmospheric Environment, Jinan University; Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution
| | - Zhi J Zhang
- Institute of Mass Spectrometer and Atmospheric Environment, Jinan University
| | - Chak K Chan
- School of Energy and Environment, City University of Hong Kong
| | - Zheng X Huang
- Institute of Mass Spectrometer and Atmospheric Environment, Jinan University; Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution
| | - Zhen Zhou
- Institute of Mass Spectrometer and Atmospheric Environment, Jinan University; Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution
| |
Collapse
|
19
|
Španěl P, Smith D. What is the real utility of breath ammonia concentration measurements in medicine and physiology? J Breath Res 2018; 12:027102. [PMID: 28972201 DOI: 10.1088/1752-7163/aa907f] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Much effort continues to be devoted to the development of devices to analyse breath ammonia with the anticipation that breath ammonia analyses will be useful in clinical practice. In this perspective we refer to the analytical techniques that have been used to measure breath ammonia, focusing on selected ion flow tube mass spectrometry, SIFT-MS, of which we have special knowledge and understanding. From the collected data obtained using the different techniques, we exam the origins of mouth- and nose-exhaled ammonia and conclude that mouth-exhaled ammonia is always elevated above a concentration that would be equilibrated with blood ammonia and is largely produced by the action of enzymes on salivary urea. Support to this conclusion is given by the reasonable correlation between blood urea concentration and mouth-exhaled ammonia concentration. Further, it is discussed that nose-exhaled ammonia largely originates at the alveolar interface and so its concentration more closely relates to the expected alveolar blood ammonia concentration. Ingestion of proteins results in increased blood/saliva urea and ultimately mouth-exhaled ammonia as does the generation of urease by H. pylori infection. It is also concluded that when mouth-exhaled ammonia is elevated then it may be due to either abnormally high blood urea, a high pH of the saliva/mouth/airways mucosa, poor oral hygiene or a combinations of these.
Collapse
Affiliation(s)
- Patrik Španěl
- J. Heyrovský Institute of Physical Chemistry, Academy of Sciences of the Czech Republic, v.v.i., Dolejškova 3, 182 23 Prague 8, Czechia
| | | |
Collapse
|
20
|
Sukul P, Oertel P, Kamysek S, Trefz P. Oral or nasal breathing? Real-time effects of switching sampling route onto exhaled VOC concentrations. J Breath Res 2017; 11:027101. [DOI: 10.1088/1752-7163/aa6368] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
21
|
Li X, Huang L, Zhu H, Zhou Z. Direct human breath analysis by secondary nano-electrospray ionization ultrahigh-resolution mass spectrometry: Importance of high mass resolution and mass accuracy. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2017; 31:301-308. [PMID: 27859758 DOI: 10.1002/rcm.7794] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2016] [Revised: 10/02/2016] [Accepted: 11/14/2016] [Indexed: 06/06/2023]
Abstract
RATIONALE Direct mass spectrometry (MS)-based methods make it possible to monitor the molecular compositions of hundreds of volatile organic compounds (VOCs) in exhaled human breath in real time. Mass resolution and mass accuracy play important roles for direct MS analysis, especially for the low-concentration isobaric compounds in non-target research. METHODS Direct detection of VOCs in exhaled breath of four healthy subjects (3 males and 1 female aged between 25 to 35 years old) has been performed by using secondary nano-electrospray ionization mass spectrometry (Sec-nanoESI-UHRMS) at resolutions (R) of 15,000, 30,000, 60,000 and 120,000. RESULTS For some low-intensity isobaric ions, they could be distinguished only when R ≥ 60,000, e.g., signals at m/z 96.9591 (sulfate/sulfuric acid), m/z 96.9687 (phosphate/phosphoric acid) and m/z 96.9756 ([C4 H2 O7 S]- ), m/z 234.1161 ([C10 H20 O3 NS]+ ) and m/z 234.1338 ([C10 H20 O5 N]+ ), m/z 119.0686 (isotope of indole) and m/z 119.0705 (an interfering signal), respectively. At R 120,000, the mass errors were obtained from a set of reference ions, and the values were ≤0.6 mDa for ions detected in positive detection mode and in the range of -1.0-1.1 mDa for the negative mode. These mass errors were used to exclusively identify unknown compounds detected in the breath samples. By utilizing the present setup, besides the normal VOCs reported previously, we detected non-volatile species (sulfate/sulfuric acid, silicate/silicic acid, phosphate/phosphoric acid and nitrate/nitric acid), dichlorobenzene and an ammonium adduct ([(C2 H6 SiO)6 + NH4 ]+ ), which were ascribed to exhaled particles, indoor air pollution and an endogenous source, respectively. CONCLUSIONS For direct breath analysis, high mass resolution of ≥60,000 and mass errors of 1.0 mDa (absolute value) covering the mass range of interests (e.g., m/z 50-500) are necessary for the exploration and accurate identification of low-intensity unknown isobaric compounds in non-target research. Copyright © 2017 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Xue Li
- Institute of Mass Spectrometry and Atmospheric Environment, Jinan University, Guangzhou, 510632, China
- Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Guangzhou, 510632, China
| | - Lei Huang
- Institute of Mass Spectrometry and Atmospheric Environment, Jinan University, Guangzhou, 510632, China
- Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Guangzhou, 510632, China
| | - Hui Zhu
- Guangzhou Hexin Instrument Co., Ltd, Guangzhou, 510530, China
| | - Zhen Zhou
- Institute of Mass Spectrometry and Atmospheric Environment, Jinan University, Guangzhou, 510632, China
- Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Guangzhou, 510632, China
| |
Collapse
|
22
|
Španěl P, Sovová K, Dryahina K, Doušová T, Dřevínek P, Smith D. Do linear logistic model analyses of volatile biomarkers in exhaled breath of cystic fibrosis patients reliably indicate
Pseudomonas aeruginosa
infection? J Breath Res 2016; 10:036013. [DOI: 10.1088/1752-7155/10/3/036013] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
23
|
Chen W, Laiho S, Vaittinen O, Halonen L, Ortiz F, Forsblom C, Groop PH, Lehto M, Metsälä M. Biochemical pathways of breath ammonia (NH
3
) generation in patients with end-stage renal disease undergoing hemodialysis. J Breath Res 2016; 10:036011. [DOI: 10.1088/1752-7155/10/3/036011] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
24
|
Bayrakli I, Turkmen A, Cem Kockar M. Feasibility Study of Using Breath Ammonia Analysis Based on Off-Axis Cavity-Enhanced Absorption Spectroscopy with External Cavity Diode Laser for Noninvasive Real-Time Diagnosis of Helicobacter Pylori. APPLIED SPECTROSCOPY 2016; 70:1269-1277. [PMID: 27296306 DOI: 10.1177/0003702816654052] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2015] [Accepted: 11/26/2015] [Indexed: 06/06/2023]
Abstract
The purpose of this study is to assess the feasibility of using breath ammonia analysis based on off-axis cavity-enhanced absorption spectroscopy (OA-CEAS) with an external-cavity diode laser (ECL) for noninvasive, real-time diagnosis of Helicobacter pylori (HP) infection. Analyses are performed for the breath of 15 healthy volunteers, and eight children and 19 adults with HP infection. The range of ammonia levels for healthy participants is determined to be between 178 and 610 ppb, whereas the ranges for child and adult patients with HP infection are measured to be 457-2470 ppb and 450-2990 ppb, respectively. The ammonia concentrations for patients with HP infection are significantly higher than the concentrations for healthy volunteers. However, no sharp boundary between the ammonia concentrations in the breath of patients with HP infection and healthy volunteers is observed. No correlation between breath ammonia and either body mass index (BMI) or age is found. The reported results suggest that our breath ammonia measurement system has the potential for future use in easy, noninvasive diagnosis of HP infection.
Collapse
Affiliation(s)
- Ismail Bayrakli
- Suleyman Demirel University, Biomedical Engineering, Bati kampusu, Isparta, Turkey
| | - Aysenur Turkmen
- Suleyman Demirel University, Biomedical Engineering, Bati kampusu, Isparta, Turkey
| | - Muhammet Cem Kockar
- Suleyman Demirel University, School of Medicine, Dogu kampusu, Isparta, Turkey
| |
Collapse
|
25
|
Brannelly NT, Hamilton-Shield JP, Killard AJ. The Measurement of Ammonia in Human Breath and its Potential in Clinical Diagnostics. Crit Rev Anal Chem 2016; 46:490-501. [PMID: 26907707 DOI: 10.1080/10408347.2016.1153949] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Ammonia is an important component of metabolism and is involved in many physiological processes. During normal physiology, levels of blood ammonia are between 11 and 50 µM. Elevated blood ammonia levels are associated with a variety of pathological conditions such as liver and kidney dysfunction, Reye's syndrome and a variety of inborn errors of metabolism including urea cycle disorders (UCD), organic acidaemias and hyperinsulinism/hyperammonaemia syndrome in which ammonia may reach levels in excess of 1 mM. It is highly neurotoxic and so effective measurement is critical for assessing and monitoring disease severity and treatment. Ammonia is also a potential biomarker in exercise physiology and studies of drug metabolism. Current ammonia testing is based on blood sampling, which is inconvenient and can be subject to significant analytical errors due to the quality of the sample draw, its handling and preparation for analysis. Blood ammonia is in gaseous equilibrium with the lungs. Recent research has demonstrated the potential use of breath ammonia as a non-invasive means of measuring systemic ammonia. This requires measurement of ammonia in real breath samples with associated temperature, humidity and gas characteristics at concentrations between 50 and several thousand parts per billion. This review explores the diagnostic applications of ammonia measurement and the impact that the move from blood to breath analysis could have on how these processes and diseases are studied and managed.
Collapse
Affiliation(s)
- N T Brannelly
- a Department of Biological Biomedical and Analytical Science , University of the West of England , Bristol , UK
| | | | - A J Killard
- a Department of Biological Biomedical and Analytical Science , University of the West of England , Bristol , UK
| |
Collapse
|
26
|
Chang A, Peng Y, Li Z, Yu X, Hong K, Zhou S, Wu W. Assembly of polythiophenes on responsive polymer microgels for the highly selective detection of ammonia gas. Polym Chem 2016. [DOI: 10.1039/c5py02014j] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A novel material that allows highly selective ammonia-to-conductance signal transduction is prepared by the assembly of polythiophenes on responsive polymer microgels.
Collapse
Affiliation(s)
- Aiping Chang
- State Key Laboratory for Physical Chemistry of Solid Surfaces
- Collaborative Innovation Center of Chemistry for Energy Materials
- The Key Laboratory for Chemical Biology of Fujian Province
- and Department of Chemistry
- College of Chemistry and Chemical Engineering
| | - Yahui Peng
- State Key Laboratory for Physical Chemistry of Solid Surfaces
- Collaborative Innovation Center of Chemistry for Energy Materials
- The Key Laboratory for Chemical Biology of Fujian Province
- and Department of Chemistry
- College of Chemistry and Chemical Engineering
| | - Zezhou Li
- State Key Laboratory for Physical Chemistry of Solid Surfaces
- Collaborative Innovation Center of Chemistry for Energy Materials
- The Key Laboratory for Chemical Biology of Fujian Province
- and Department of Chemistry
- College of Chemistry and Chemical Engineering
| | - Xiang Yu
- Chemical Sciences Division
- Oak Ridge National Laboratory
- Oak Ridge
- USA
- Center for Nanophase Materials Sciences
| | - Kunlun Hong
- Center for Nanophase Materials Sciences
- Oak Ridge National Laboratory
- Oak Ridge
- USA
| | - Shuiqin Zhou
- Department of Chemistry and The Center for Engineered Polymeric Materials of College of Staten Island
- and The Graduate Center
- The City University of New York
- Staten Island
- USA
| | - Weitai Wu
- State Key Laboratory for Physical Chemistry of Solid Surfaces
- Collaborative Innovation Center of Chemistry for Energy Materials
- The Key Laboratory for Chemical Biology of Fujian Province
- and Department of Chemistry
- College of Chemistry and Chemical Engineering
| |
Collapse
|
27
|
Human Excreta as a Stable and Important Source of Atmospheric Ammonia in the Megacity of Shanghai. PLoS One 2015; 10:e0144661. [PMID: 26656636 PMCID: PMC4681533 DOI: 10.1371/journal.pone.0144661] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2015] [Accepted: 11/20/2015] [Indexed: 11/19/2022] Open
Abstract
Although human excreta as a NH3 source has been recognized globally, this source has never been quantitatively determined in cities, hampering efforts to fully assess the causes of urban air pollution. In the present study, the exhausts of 15 ceiling ducts from collecting septic tanks in 13 buildings with 6 function types were selected to quantify NH3 emission rates in the megacity of Shanghai. As a comparison, the ambient NH3 concentrations across Shanghai were also measured at 13 atmospheric monitoring sites. The concentrations of NH3 in the ceiling ducts (2809(-2661)(+5803) μg m(-3)) outweigh those of the open air (~10 μg m(-3)) by 2-3 orders of magnitude, and there is no significant difference between different seasons. δ15N values of NH3 emitted from two ceiling ducts are also seasonally consistent, suggesting that human excreta may be a stable source of NH3 in urban areas. The NH3 concentration levels were variable and dependent on the different building types and the level of human activity. NH3 emission rates of the six residential buildings (RBNH3) were in agreement with each other. Taking occupation time into account, we confined the range of the average NH3 emission factor for human excreta to be 2-4 times (with the best estimate of 3 times) of the averaged RBNH3 of 66.0±58.9 g NH3 capita(-1) yr(-1). With this emission factor, the population of ~21 million people living in the urban areas of Shanghai annually emitted approximately 1386 Mg NH3, which corresponds to over 11.4% of the total NH3 emissions in the Shanghai urban areas. The spatial distribution of NH3 emissions from human excreta based on population data was calculated for the city of Shanghai at a high-resolution (100×100 m). Our results demonstrate that human excreta should be included in official ammonia emission inventories.
Collapse
|
28
|
Mochalski P, Unterkofler K, Teschl G, Amann A. Potential of volatile organic compounds as markers of entrapped humans for use in urban search-and-rescue operations. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2015.02.013] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
29
|
Smith D, Spanel P. Pitfalls in the analysis of volatile breath biomarkers: suggested solutions and SIFT-MS quantification of single metabolites. J Breath Res 2015; 9:022001. [PMID: 25830501 DOI: 10.1088/1752-7155/9/2/022001] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The experimental challenges presented by the analysis of trace volatile organic compounds (VOCs) in exhaled breath with the objective of identifying reliable biomarkers are brought into focus. It is stressed that positive identification and accurate quantification of the VOCs are imperative if they are to be considered as discreet biomarkers. Breath sampling procedures are discussed and it is suggested that for accurate quantification on-line real time sampling and analysis is desirable. Whilst recognizing such real time analysis is not always possible and sample collection is often required, objective recognition of the pitfalls involved in this is essential. It is also emphasized that mouth-exhaled breath is always contaminated to some degree by orally generated compounds and so, when possible, analysis of nose-exhaled breath should be performed. Some difficulties in breath analysis are mitigated by the choice of analytical instrumentation used, but no single instrument can provide solutions to all the analytical challenges. Analysis and interpretation of breath analysis data, however acquired, needs to be treated circumspectly. In particular, the excessive use of statistics to treat imperfect mass spectrometry/mobility spectra should be avoided, since it can result in unjustifiable conclusions. It is should be understood that recognition of combinations of VOCs in breath that, for example, apparently describe particular cancer states, will not be taken seriously until they are replicated in other laboratories and clinics. Finally, the inhibiting notion that single biomarkers of infection and disease will not be identified and utilized clinically should be dispelled by the exemplary and widely used single biomarkers NO and H2 and now, as indicated by recent selected ion flow tube mass spectroscopy (SIFT-MS) results, triatomic hydrogen cyanide and perhaps pentane and acetic acid. Hopefully, these discoveries will provide encouragement to research workers to be more open-minded on this important and desirable issue.
Collapse
Affiliation(s)
- David Smith
- Institute for Science and Technology in Medicine, School of Medicine, Keele University, Thornburrow Drive, Hartshill, Stoke-on-Trent ST4 7QB, UK
| | | |
Collapse
|
30
|
Trace detection of endogenous human volatile organic compounds for search, rescue and emergency applications. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2014.11.018] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
31
|
Peng Y, Jiang X, Chen S, Wu Q, Shen J, Wu W. Synthesis and characterization of ammonia-responsive polymer microgels. Polym Chem 2015. [DOI: 10.1039/c5py01531f] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We report a polymer microgel that can undergo rapid, reversible, and highly-sensitive volume phase transitions upon varying ammonia concentrations in milieu.
Collapse
Affiliation(s)
- Yahui Peng
- State Key Laboratory for Physical Chemistry of Solid Surfaces
- The Key Laboratory for Chemical Biology of Fujian Province
- and Department of Chemistry
- College of Chemistry and Chemical Engineering
- Xiamen University
| | - Xiaomei Jiang
- Clinical Laboratory
- Huli Center for Maternal and Child Health
- Xiamen 361009
- China
| | - Shoumin Chen
- State Key Laboratory for Physical Chemistry of Solid Surfaces
- The Key Laboratory for Chemical Biology of Fujian Province
- and Department of Chemistry
- College of Chemistry and Chemical Engineering
- Xiamen University
| | - Qingshi Wu
- State Key Laboratory for Physical Chemistry of Solid Surfaces
- The Key Laboratory for Chemical Biology of Fujian Province
- and Department of Chemistry
- College of Chemistry and Chemical Engineering
- Xiamen University
| | - Jing Shen
- Department of Applied Chemistry
- College of Vocational Education
- Yunnan Normal University
- Kunming 650092
- China
| | - Weitai Wu
- State Key Laboratory for Physical Chemistry of Solid Surfaces
- The Key Laboratory for Chemical Biology of Fujian Province
- and Department of Chemistry
- College of Chemistry and Chemical Engineering
- Xiamen University
| |
Collapse
|
32
|
Smith D, Španěl P. SIFT-MS and FA-MS methods for ambient gas phase analysis: developments and applications in the UK. Analyst 2015; 140:2573-91. [DOI: 10.1039/c4an02049a] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The origins of SIFT created to study interstellar chemistry and SIFT-MS developed for ambient gas and exhaled breath analysis and the UK centres in which these techniques are being exploited.
Collapse
Affiliation(s)
- David Smith
- Institute for Science and Technology in Medicine – Keele University
- Guy Hilton Research Centre
- Stoke-on-Trent
- UK
| | - Patrik Španěl
- Institute for Science and Technology in Medicine – Keele University
- Guy Hilton Research Centre
- Stoke-on-Trent
- UK
- J. Heyrovský Institute of Physical Chemistry
| |
Collapse
|
33
|
Berchtold C, Bosilkovska M, Daali Y, Walder B, Zenobi R. Real-time monitoring of exhaled drugs by mass spectrometry. MASS SPECTROMETRY REVIEWS 2014; 33:394-413. [PMID: 24272872 DOI: 10.1002/mas.21393] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2013] [Revised: 06/12/2013] [Accepted: 06/13/2013] [Indexed: 06/02/2023]
Abstract
Future individualized patient treatment will need tools to monitor the dose and effects of administrated drugs. Mass spectrometry may become the method of choice to monitor drugs in real time by analyzing exhaled breath. This review describes the monitoring of exhaled drugs in real time by mass spectrometry. The biological background as well as the relevant physical properties of exhaled drugs are delineated. The feasibility of detecting and monitoring exhaled drugs is discussed in several examples. The mass spectrometric tools that are currently available to analyze breath in real time are reviewed. The technical needs and state of the art for on-site measurements by mass spectrometry are also discussed in detail. Off-line methods, which give support and are an important source of information for real-time measurements, are also discussed. Finally, some examples of drugs that have already been successfully detected in exhaled breath, including propofol, fentanyl, methadone, nicotine, and valproic acid are presented. Real-time monitoring of exhaled drugs by mass spectrometry is a relatively new field, which is still in the early stages of development. New technologies promise substantial benefit for future patient monitoring and treatment.
Collapse
Affiliation(s)
- Christian Berchtold
- Department of Chemistry and Applied Biosciences, ETH Zürich, CH-8093, Zürich, Switzerland
| | | | | | | | | |
Collapse
|
34
|
Abstract
It is known that the oral cavity is a production site for mouth-exhaled NH3. However, the mechanism of NH3 production in the oral cavity has been unclear. Since bacterial urease in the oral cavity has been found to produce ammonia from oral fluid urea, we hypothesize that oral fluid urea is the origin of mouth-exhaled NH3. Our results show that under certain conditions a strong correlation exists between oral fluid urea and oral fluid ammonia (NH4(+)+NH3) (rs = 0.77, p < 0.001). We also observe a strong correlation between oral fluid NH3 and mouth-exhaled NH3 (rs = 0.81, p < 0.001). We conclude that three main factors affect the mouth-exhaled NH3 concentration: urea concentration, urease activity and oral fluid pH. Bacterial urease catalyses the hydrolysis of oral fluid urea to ammonia (NH4(+)+NH3). Oral fluid ammonia (NH4(+)+NH3) and pH determine the concentration of oral fluid NH3, which evaporates from oral fluid into gas phase and turns to mouth-exhaled NH3.
Collapse
Affiliation(s)
- W Chen
- Laboratory of Physical Chemistry, Department of Chemistry, PO Box 55 (A. I. Virtasen aukio 1), FI-00014 University of Helsinki, Finland
| | | | | | | |
Collapse
|
35
|
Wondimu T, Wang R, Ross B. Hydrogen sulphide in human nasal air quantified using thermal desorption and selected ion flow tube mass spectrometry. J Breath Res 2014; 8:036002. [PMID: 25079905 DOI: 10.1088/1752-7155/8/3/036002] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
The discovery that hydrogen sulphide (H2S) acts as a gasotransmitter when present at very low concentrations (sub-parts per billion (ppbv)) has resulted in the need to quickly quantify trace amounts of the gas in complex biological samples. Selected ion flow tube mass spectrometry (SIFT-MS) is capable of real-time quantification of H2S but many SIFT-MS instruments lack sufficient sensitivity for this application. In this study we investigate the utility of combining thermal desorption with SIFT-MS for quantifying H2S in the 0.1-1 ppbv concentration range. Human orally or nasally derived breath, and background ambient air, were collected in sampling bags and dried by passing through CaCl2 and H2S pre-concentrated using a sorbent trap optimised for the capture of this gas. The absorbed H2S was then thermally desorbed and quantified by SIFT-MS. H2S concentrations in ambient air, nasal breath and oral breath collected from 10 healthy volunteers were 0.12 ± 0.02 (mean ± SD), 0.40 ± 0.11 and 3.1 ± 2.5 ppbv respectively, and in the oral cavity H2S, quantified by SIFT-MS without pre-concentration, was present at 13.5 ± 8.6 ppbv. The oral cavity H2S correlates well with oral breath H2S but not with nasal breath H2S, suggesting that oral breath H2S derives mainly from the oral cavity but nasal breath is likely pulmonary in origin. The successful quantification of such low concentrations of H2S in nasal air using a rapid analytical procedure paves the way for the straightforward analysis of H2S in breath and may assist in elucidating the role that H2S plays in biological systems.
Collapse
Affiliation(s)
- Taddese Wondimu
- Division of Medical Sciences, Northern Ontario School of Medicine, Lakehead University, 955 Oliver Road, Thunder Bay, ON P7B5E1, Canada. Department of Chemistry, Johannesburg, South Africa
| | | | | |
Collapse
|
36
|
Lourenço C, Turner C. Breath analysis in disease diagnosis: methodological considerations and applications. Metabolites 2014; 4:465-98. [PMID: 24957037 PMCID: PMC4101517 DOI: 10.3390/metabo4020465] [Citation(s) in RCA: 141] [Impact Index Per Article: 14.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2014] [Revised: 06/02/2014] [Accepted: 06/09/2014] [Indexed: 02/07/2023] Open
Abstract
Breath analysis is a promising field with great potential for non-invasive diagnosis of a number of disease states. Analysis of the concentrations of volatile organic compounds (VOCs) in breath with an acceptable accuracy are assessed by means of using analytical techniques with high sensitivity, accuracy, precision, low response time, and low detection limit, which are desirable characteristics for the detection of VOCs in human breath. "Breath fingerprinting", indicative of a specific clinical status, relies on the use of multivariate statistics methods with powerful in-built algorithms. The need for standardisation of sample collection and analysis is the main issue concerning breath analysis, blocking the introduction of breath tests into clinical practice. This review describes recent scientific developments in basic research and clinical applications, namely issues concerning sampling and biochemistry, highlighting the diagnostic potential of breath analysis for disease diagnosis. Several considerations that need to be taken into account in breath analysis are documented here, including the growing need for metabolomics to deal with breath profiles.
Collapse
Affiliation(s)
- Célia Lourenço
- Department of Life, Health & Chemical Sciences, Chemistry and Analytical Sciences, The Open University, Walton Hall, Milton Keynes, MK7 6AA, UK.
| | - Claire Turner
- Department of Life, Health & Chemical Sciences, Chemistry and Analytical Sciences, The Open University, Walton Hall, Milton Keynes, MK7 6AA, UK.
| |
Collapse
|
37
|
Smith D, Španěl P, Herbig J, Beauchamp J. Mass spectrometry for real-time quantitative breath analysis. J Breath Res 2014; 8:027101. [PMID: 24682047 DOI: 10.1088/1752-7155/8/2/027101] [Citation(s) in RCA: 117] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
38
|
Breath analysis of ammonia, volatile organic compounds and deuterated water vapor in chronic kidney disease and during dialysis. Bioanalysis 2014; 6:843-57. [DOI: 10.4155/bio.14.26] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023] Open
Abstract
The volatile metabolites present in trace amounts in exhaled breath of healthy individuals and patients, for example those with advanced chronic kidney disease (CKD), can now be detected and quantified by sensitive analytical techniques. In this review, special attention is given to the major retention metabolites resulting from dialysis-dependent CKD stage 5 and especially ammonia, as a potential estimator of the severity of uremia. However, other biomarkers are important, including the hydrocarbons isoprene, ethane and pentane, in that they are likely to indicate tissue injury associated with the dialysis treatment itself. Evaluation of over-hydration, a serious complication of CKD stage5 can be improved by analysis of deuterium in exhaled water vapor after ingestion of a known amount of deuterated water, so providing total body water measurements at the bedside to support clinical management of volume status.
Collapse
|
39
|
Hibbard T, Crowley K, Kelly F, Ward F, Holian J, Watson A, Killard AJ. Point of care monitoring of hemodialysis patients with a breath ammonia measurement device based on printed polyaniline nanoparticle sensors. Anal Chem 2013; 85:12158-65. [PMID: 24299143 DOI: 10.1021/ac403472d] [Citation(s) in RCA: 89] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
A device for measuring human breath ammonia was developed based on a single use, disposable, inkjet printed ammonia sensor fabricated using polyaniline nanoparticles. The device was optimized for sampling ammonia in human breath samples by addressing issues such as variations in breath sample volume, flow rate, sources of oral ammonia, temperature and humidity. The resulting system was capable of measuring ammonia in breath from 40 to 2993 ppbv (r(2 )= 0.99, n = 3) as correlated with photoacoustic laser spectroscopy and correlation in normal human breath samples yielded a slope of 0.93 and a Pearson correlation coefficient of 0.9705 (p < 0.05, n = 11). Measurement of ammonia in the breath of patients with end-stage kidney disease demonstrated its significant reduction following dialysis, while also correlating well with blood urea nitrogen (BUN) (r = 0.61, p < 0.01, n = 96). Excellent intraindividual correlations were demonstrated between breath ammonia and BUN (0.86 to 0.96), which demonstrates the possibility of using low cost point of care breath ammonia systems as a noninvasive means of monitoring kidney dysfunction and treatment.
Collapse
Affiliation(s)
- Troy Hibbard
- Biomedical Diagnostics Institute, Dublin City University , Dublin D9, Ireland
| | | | | | | | | | | | | |
Collapse
|
40
|
Smith D, Španěl P, Gilchrist FJ, Lenney W. Hydrogen cyanide, a volatile biomarker of
Pseudomonas aeruginosa
infection. J Breath Res 2013; 7:044001. [DOI: 10.1088/1752-7155/7/4/044001] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
41
|
Effects of dietary nutrients on volatile breath metabolites. J Nutr Sci 2013; 2:e34. [PMID: 25191584 PMCID: PMC4153095 DOI: 10.1017/jns.2013.26] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2013] [Revised: 07/22/2013] [Accepted: 07/25/2013] [Indexed: 12/22/2022] Open
Abstract
Breath analysis is becoming increasingly established as a means of assessing metabolic,
biochemical and physiological function in health and disease. The methods available for
these analyses exploit a variety of complex physicochemical principles, but are becoming
more easily utilised in the clinical setting. Whilst some of the factors accounting for
the biological variation in breath metabolite concentrations have been clarified, there
has been relatively little work on the dietary factors that may influence them. In
applying breath analysis to the clinical setting, it will be important to consider how
these factors may affect the interpretation of endogenous breath composition. Diet may
have complex effects on the generation of breath compounds. These effects may either be
due to a direct impact on metabolism, or because they alter the gastrointestinal flora.
Bacteria are a major source of compounds in breath, and their generation of H2,
hydrogen cyanide, aldehydes and alkanes may be an indicator of the health of their
host.
Collapse
|
42
|
Detection of volatile organic compounds as biomarkers in breath analysis by different analytical techniques. Bioanalysis 2013; 5:2287-306. [DOI: 10.4155/bio.13.183] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023] Open
Abstract
Breath is a rich mixture containing numerous volatile organic compounds at trace amounts (ppbv–pptv level) such as: hydrocarbons, alcohols, ketones, aldehydes, esters or heterocycles. The presence of some of them depends on health status. Therefore, breath analysis might be useful for clinical diagnostics, therapy monitoring and control of metabolic or biochemical cell cycle products. This Review presents an update on the latest developments in breath analysis applied to diagnosing different diseases with the help of high-quality equipment. Efforts were made to fully and accurately describe traditional and modern techniques used to determine the components of breath. The techniques were compared in terms of design, function and also detection limit of different volatile organic compounds. GC with different detectors, MS, optical sensor and laser spectroscopic detection techniques are also discussed.
Collapse
|
43
|
Solga SF, Mudalel M, Spacek LA, Lewicki R, Tittel F, Loccioni C, Russo A, Risby TH. Factors influencing breath ammonia determination. J Breath Res 2013; 7:037101. [PMID: 23774041 DOI: 10.1088/1752-7155/7/3/037101] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Amongst volatile compounds (VCs) present in exhaled breath, ammonia has held great promise and yet it has confounded researchers due to its inherent reactivity. Herein we have evaluated various factors in both breath instrumentation and the breath collection process in an effort to reduce variability. We found that the temperature of breath sampler and breath sensor, mouth rinse pH, and mode of breathing to be important factors. The influence of the rinses is heavily dependent upon the pH of the rinse. The basic rinse (pH 8.0) caused a mean increase of the ammonia concentration by 410 ± 221 ppb. The neutral rinse (pH 7.0), slightly acidic rinse (pH 5.8), and acidic rinse (pH 2.5) caused a mean decrease of the ammonia concentration by 498 ± 355 ppb, 527 ± 198 ppb, and 596 ± 385 ppb, respectively. Mode of breathing (mouth-open versus mouth-closed) demonstrated itself to have a large impact on the rate of recovery of breath ammonia after a water rinse. Within 30 min, breath ammonia returned to 98 ± 16% that of the baseline with mouth open breathing, while mouth closed breathing allowed breath ammonia to return to 53 ± 14% of baseline. These results contribute to a growing body of literature that will improve reproducibly in ammonia and other VCs.
Collapse
|
44
|
Schmidt FM, Vaittinen O, Metsälä M, Lehto M, Forsblom C, Groop PH, Halonen L. Ammonia in breath and emitted from skin. J Breath Res 2013; 7:017109. [PMID: 23445955 DOI: 10.1088/1752-7155/7/1/017109] [Citation(s) in RCA: 71] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Ammonia concentrations in exhaled breath (eNH3) and skin gas of 20 healthy subjects were measured on-line with a commercial cavity ring-down spectrometer and compared to saliva pH and plasma ammonium ion (NH(+)4), urea and creatinine concentrations. Special attention was given to mouth, nose and skin sampling procedures and the accurate quantification of ammonia in humid gas samples. The obtained median concentrations were 688 parts per billion by volume (ppbv) for mouth-eNH3, 34 ppbv for nose-eNH3, and 21 ppbv for both mouth- and nose-eNH3 after an acidic mouth wash (MW). The median ammonia emission rate from the lower forearm was 0.3 ng cm(-2) min(-1). Statistically significant (p < 0.05) correlations between the breath, skin and plasma ammonia/ammonium concentrations were not found. However, mouth-eNH3 strongly (p < 0.001) correlated with saliva pH. This dependence was also observed in detailed measurements of the diurnal variation and the response of eNH3 to the acidic MW. It is concluded that eNH3 as such does not reflect plasma but saliva and airway mucus NH(+)4 concentrations and is affected by saliva and airway mucus pH. After normalization with saliva pH using the Henderson-Hasselbalch equation, mouth-eNH3 correlated with plasma NH(+)4, which points to saliva and plasma NH(+)4 being linked via hydrolysis of salivary urea.
Collapse
Affiliation(s)
- F M Schmidt
- Laboratory of Physical Chemistry, Department of Chemistry, University of Helsinki, Finland.
| | | | | | | | | | | | | |
Collapse
|
45
|
Spaněl P, Dryahina K, Smith D. A quantitative study of the influence of inhaled compounds on their concentrations in exhaled breath. J Breath Res 2013; 7:017106. [PMID: 23445832 DOI: 10.1088/1752-7155/7/1/017106] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Throughout the development of breath analysis research, there has been interest in how the concentrations of trace compounds in exhaled breath are related to their concentrations in the ambient inhaled air. In considering this, Phillips introduced the concept of 'alveolar gradient' and judged that the measured exhaled concentrations of volatile organic compounds should be diminished by an amount equal to their concentrations in the inhaled ambient air. The objective of the work described in this paper was to investigate this relationship quantitatively. Thus, experiments have been carried out in which inhaled air was polluted by seven compounds of interest in breath research, as given below, and exhaled breath has been analysed by SIFT-MS as the concentrations of these compounds in the inhaled air were reduced. The interesting result obtained is that all the exogenous compounds are partially retained in the exhaled breath and there are close linear relationships between the exhaled and inhaled air concentrations for all seven compounds. Thus, retention coefficients, a, have been derived for the following compounds: pentane, 0.76 ± 0.09; isoprene, 0.66 ± 0.04; acetone, 0.17 ± 0.03; ammonia, 0.70 ± 0.13, methanol, 0.29 ± 0.02; formaldehyde, 0.06 ± 0.03; deuterated water (HDO), 0.09 ± 0.02. From these data, correction to breath analyses for inhaled concentration can be described by coefficients specific to each compound, which can be close to 1 for hydrocarbons, as applied by Phillips, or around 0.1, meaning that inhaled concentrations of such compounds can essentially be neglected. A further deduction from the experimental data is that under conditions of the inhalation of clean air, the measured exhaled breath concentrations of those compounds should be increased by a factor of 1/(1 - a) to correspond to gaseous equilibrium with the compounds dissolved in the mixed venous blood entering the alveoli. Thus, for isoprene, this is a factor of 3, which we have confirmed experimentally by re-breathing experiments.
Collapse
Affiliation(s)
- Patrik Spaněl
- J Heyrovsky Institute of Physical Chemistry, Academy of Sciences of the Czech Republic, Dolejskova 3, Prague 8, Czech Republic.
| | | | | |
Collapse
|
46
|
Khalid TY, Saad S, Greenman J, de Lacy Costello B, Probert CSJ, Ratcliffe NM. Volatiles from oral anaerobes confounding breath biomarker discovery. J Breath Res 2013; 7:017114. [DOI: 10.1088/1752-7155/7/1/017114] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
47
|
Spanel P, Smith D. On the features, successes and challenges of selected ion flow tube mass spectrometry. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2013; 19:225-246. [PMID: 24575622 DOI: 10.1255/ejms.1240] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The major features of the selected ion flow tube mass spectrometry (SIFT-MS) analytical method that was conceived and designed for the analysis, in real time, of air obviating sample collections into bags or extraction by pre-concentration of trace compounds onto surfaces are reviewed. The unique analytical capabilities of SIFT-MS for ambient analysis are stressed that allow quantification of volatile organic and inorganic compounds directly from the measurement of physical parameters without the need for regular instrumental calibration using internal or external standards. Then, emphasis is placed on the challenging real-time accurate analysis of single exhalations of humid breath, which is now achieved and readily facilitates wider applications of SIFT-MS in other fields where trace gas analysis has value. The quality of the data obtained by SIFT-MS is illustrated by the quantification of some exhaled breath metabolites that are of immediate relevance to physiology and medicine, including that of hydrogen cyanide in the breath of patients with cystic fibrosis. The current status of SIFT-MS is revealed by a form of a strengths, weakness, opportunities and threats (SWOT) analysis intended to present an objective view of this analytical technique and the likely way forward towards its further development and application.
Collapse
Affiliation(s)
- Patrik Spanel
- J. Heyrovsky Institute of Physical Chemistry, Academy of Sciences of the Czech Republic, DolejSkova 3, 182 23, Prague 8, Czech Republic
| | - David Smith
- lnstitute for Science and Technology in Medicine, Keele University, Guy Hilton Research Centre, Thornburrow Drive, Hartshill, Stoke-on-Trent ST4 7QB, UK
| |
Collapse
|
48
|
Chuikova KI, Kistenev YV, Gomboeva SS. Applying of gas analysis in diagnostic of liver diseases. BULLETIN OF SIBERIAN MEDICINE 2012. [DOI: 10.20538/1682-0363-2012-6-178-184] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
49
|
Imran M, Shah Y, Nundlall S, Roberts NB, Howse M. Is blood ammonia influenced by kidney function? A prospective study. Clin Biochem 2012; 45:363-5. [DOI: 10.1016/j.clinbiochem.2011.12.015] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2011] [Revised: 12/15/2011] [Accepted: 12/18/2011] [Indexed: 12/31/2022]
|
50
|
Dummer J, Storer M, Swanney M, McEwan M, Scott-Thomas A, Bhandari S, Chambers S, Dweik R, Epton M. Analysis of biogenic volatile organic compounds in human health and disease. Trends Analyt Chem 2011. [DOI: 10.1016/j.trac.2011.03.011] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|