1
|
Ishii H, Shibuya M, Leung GNW, Nozawa S, Yamashita S, Yamada M, Kushiro A, Kasashima Y, Okada J, Kawasaki K, Kijima-Suda I. Detection and longitudinal distribution of GW1516 and its metabolites in equine hair for doping control using liquid chromatography/high-resolution mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35:e9050. [PMID: 33470485 DOI: 10.1002/rcm.9050] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 01/18/2021] [Accepted: 01/18/2021] [Indexed: 06/12/2023]
Abstract
RATIONALE GW1516 is a peroxisome proliferator-activated receptor-δ (PPAR-δ) agonist that is banned in horseracing and equestrian sports. Long-term detection and longitudinal distribution of GW1516 in the mane of a horse are reported for the first time and this hair analysis could prolong the detection window of GW1516 for doping control. METHODS Mane hairs were divided into three segments (0-7, 7-15, and >15 cm from the cut end) and completely pulverized and homogenized for analysis. The pulverized hair samples were extracted with methanol followed by further purification and the extracts were analyzed by liquid chromatography/electrospray ionization high-resolution mass spectrometry (LC/ESI-HRMS) using a Q-Exactive instrument. This method was successfully validated and applied to post-administration samples to confirm the presence of GW1516 and its metabolites and estimate the uptake amounts of GW1516. RESULTS After administration of 150 mg of GW1516 to a thoroughbred mare, GW1516 was detected in one of two segments of all mane hairs, and four metabolites, namely GW1516 sulfoxide, GW1516 sulfone, 5-(hydroxymethyl)-4-methyl-2-(4-trifluoromethylphenyl)thiazole (HMTT), and 4-methyl-2-[4-(trifluoromethyl)phenyl]-1,3-thiazole-5-carboxylic acid (MTTC), were also identified. The longitudinal distribution analysis results showed that the maximum uptake of GW1516 into hair (approximately 0.05 pg/mg) was observed at around 13 weeks post-administration and GW1516 could be detected and confirmed up to 6 months post-administration. CONCLUSIONS The parent drug GW1516 was identified as the most appropriate monitoring target in equine hair for controlling its misuse in horses. The use of hair analysis could extend the detection time of GW1516 to at least 6 months after the administration of 150 mg of GW1516 to a thoroughbred mare.
Collapse
Affiliation(s)
- Hideaki Ishii
- Drug Analysis Department, Laboratory of Racing Chemistry, 1731-2 Tsuruta-machi, Utsunomiya, Tochigi, 320-0851, Japan
- Department of Pharmaceutical Sciences, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Mariko Shibuya
- Drug Analysis Department, Laboratory of Racing Chemistry, 1731-2 Tsuruta-machi, Utsunomiya, Tochigi, 320-0851, Japan
| | - Gary Ngai-Wa Leung
- Drug Analysis Department, Laboratory of Racing Chemistry, 1731-2 Tsuruta-machi, Utsunomiya, Tochigi, 320-0851, Japan
| | - Satoshi Nozawa
- Drug Analysis Department, Laboratory of Racing Chemistry, 1731-2 Tsuruta-machi, Utsunomiya, Tochigi, 320-0851, Japan
| | - Shozo Yamashita
- Drug Analysis Department, Laboratory of Racing Chemistry, 1731-2 Tsuruta-machi, Utsunomiya, Tochigi, 320-0851, Japan
| | - Masayuki Yamada
- Drug Analysis Department, Laboratory of Racing Chemistry, 1731-2 Tsuruta-machi, Utsunomiya, Tochigi, 320-0851, Japan
| | - Asuka Kushiro
- Research Planning & Coordination Division, JRA, Equine Research Institute, 1400-4, Shiba, Shimotsuke, Tochigi, 329-0412, Japan
| | - Yoshinori Kasashima
- Research Planning & Coordination Division, JRA, Equine Research Institute, 1400-4, Shiba, Shimotsuke, Tochigi, 329-0412, Japan
| | - Jun Okada
- Veterinarian Section, Equine Department, Japan Racing Association, 6-11-1 Roppongi, Minato-ku, Tokyo, 105-0003, Japan
| | - Kazumi Kawasaki
- Veterinarian Section, Equine Department, Japan Racing Association, 6-11-1 Roppongi, Minato-ku, Tokyo, 105-0003, Japan
| | - Isao Kijima-Suda
- Drug Analysis Department, Laboratory of Racing Chemistry, 1731-2 Tsuruta-machi, Utsunomiya, Tochigi, 320-0851, Japan
| |
Collapse
|
2
|
Lan J, Kaeslin J, Greter G, Zenobi R. Minimizing ion competition boosts volatile metabolome coverage by secondary electrospray ionization orbitrap mass spectrometry. Anal Chim Acta 2021; 1150:338209. [DOI: 10.1016/j.aca.2021.338209] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Revised: 01/04/2021] [Accepted: 01/05/2021] [Indexed: 01/20/2023]
|
3
|
Kaufmann A. High-resolution mass spectrometry for bioanalytical applications: Is this the new gold standard? JOURNAL OF MASS SPECTROMETRY : JMS 2020; 55:e4533. [PMID: 32559824 DOI: 10.1002/jms.4533] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Revised: 11/19/2019] [Accepted: 04/18/2020] [Indexed: 06/11/2023]
Abstract
Liquid chromatography coupled to quadrupole-based tandem mass spectrometry (QqQ) is termed the "gold standard" for bioanalytical applications because of its unpreceded selectivity, sensitivity, and the ruggedness of the technology. More recently, however, high-resolution mass spectrometry (HRMS) has become increasingly popular for bioanalytical applications. Nonetheless, this technique is still viewed, either as a screening technology or as a research tool. Although HRMS is actively discussed during scientific conferences, it is yet to be widely utilised in routine laboratory settings and there remains a reluctance to use HRMS for quantitative measurements in regulated environments. This paper does not aim to comprehensively describe the potential of the latest HRMS technology, but rather, it focuses on what results can be obtained and outlines the author's experiences over a period of many years of the routine application of various forms of HRMS instrumentation. Fifteen years ago, some nine different QqQ methods were used in the author's laboratory to analyse a variety of different veterinary drug resides. Today, many more analytes are quantified by seven HRMS methods and just three QqQ methods remain in use for the analysis of a small set of compounds yet to be upgraded to HRMS analysis. This continual upgrading and migration of analytical methods were accompanied by regularly participating in laboratory proficiency tests (PTs). The PT reports (covering a range of analytes and analytical methods) were used to compare the accuracy of HRMS- versus QqQ-based measurements. In the second part of this paper, the particular strengths and limitations of HRMS for both method development and routine measurements are critically discussed. This also includes some anecdotal experiences encountered when replacing QqQ assays with HRMS methods.
Collapse
Affiliation(s)
- Anton Kaufmann
- Official Food Control Authority of the Canton of Zürich, Fehrenstrasse 15, Zürich, 8032, Switzerland
| |
Collapse
|
4
|
Monaci L, Pilolli R, De Angelis E, Crespo JF, Novak N, Cabanillas B. Food allergens: Classification, molecular properties, characterization, and detection in food sources. ADVANCES IN FOOD AND NUTRITION RESEARCH 2020; 93:113-146. [PMID: 32711861 DOI: 10.1016/bs.afnr.2020.03.001] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Food allergy is a large and growing public health problem in many areas of the world. The prevalence of food allergy has increased in the last decades in a very significant way in many world regions, particularly in developed countries. In that respect, the research field of food allergy has experienced an extensive growth and very relevant progress has been made in recent years regarding the characterization of food allergens, the study of their immunological properties, and their detection in food sources. Furthermore, food labeling policies have also been improved decidedly in recent years. For that immense progress made, it is about time to review the latest progress in the field of food allergy. In this review, we intend to carry out an extensive and profound overview regarding the latest scientific advances and knowledge in the field of food allergen detection, characterization, and in the study of the effects of food processing on the physico-chemical properties of food allergens. The advances in food labeling policies, and methodologies for the characterization of food allergens are also thoroughly reviewed in the present overview.
Collapse
Affiliation(s)
- Linda Monaci
- Institute of Sciences of Food Production, CNR-ISPA, Bari, Italy
| | - Rosa Pilolli
- Institute of Sciences of Food Production, CNR-ISPA, Bari, Italy
| | | | - Jesus F Crespo
- Department of Allergy, Research Institute Hospital 12 de Octubre de Madrid, Madrid, Spain
| | - Natalija Novak
- Department of Dermatology and Allergy, University Hospital Bonn, Bonn, Germany
| | - Beatriz Cabanillas
- Department of Allergy, Research Institute Hospital 12 de Octubre de Madrid, Madrid, Spain.
| |
Collapse
|
5
|
Cavaliere C, Antonelli M, Capriotti AL, La Barbera G, Montone CM, Piovesana S, Laganà A. A Triple Quadrupole and a Hybrid Quadrupole Orbitrap Mass Spectrometer in Comparison for Polyphenol Quantitation. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2019; 67:4885-4896. [PMID: 30977362 DOI: 10.1021/acs.jafc.8b07163] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Liquid chromatography coupled to low-resolution mass spectrometry (LRMS) has historically been a popular approach for compound quantitation. Recently, high-resolution mass spectrometry (HRMS) technical developments led to the introduction of new approaches for quantitative analysis. Whereas the performances of HRMS have been largely assessed for qualitative purposes, there are still questions about its suitability for quantitative analysis. Several papers on LRMS and HRMS comparison have been published; however, none of them was applied to polyphenol quantitation. In this work, a comparison between HRMS, operated in data-dependent acquisition mode, and LRMS, operated in selected-reaction-monitoring mode, was performed for polyphenol quantitation in wine. The two techniques were evaluated in terms of sensitivity, linearity range, matrix effect, and precision, showing the better performances of HRMS. The suitability of HRMS for quantitation purposes as well as qualitative screening makes HRMS the new technique of choice for both targeted and untargeted analysis.
Collapse
Affiliation(s)
- Chiara Cavaliere
- Department of Chemistry , University of Rome "La Sapienza" , Piazzale Aldo Moro 5 , Rome 00185 , Italy
| | - Michela Antonelli
- Department of Chemistry , University of Rome "La Sapienza" , Piazzale Aldo Moro 5 , Rome 00185 , Italy
| | - Anna Laura Capriotti
- Department of Chemistry , University of Rome "La Sapienza" , Piazzale Aldo Moro 5 , Rome 00185 , Italy
| | - Giorgia La Barbera
- Department of Chemistry , University of Rome "La Sapienza" , Piazzale Aldo Moro 5 , Rome 00185 , Italy
| | - Carmela Maria Montone
- Department of Chemistry , University of Rome "La Sapienza" , Piazzale Aldo Moro 5 , Rome 00185 , Italy
| | - Susy Piovesana
- Department of Chemistry , University of Rome "La Sapienza" , Piazzale Aldo Moro 5 , Rome 00185 , Italy
| | - Aldo Laganà
- Department of Chemistry , University of Rome "La Sapienza" , Piazzale Aldo Moro 5 , Rome 00185 , Italy
| |
Collapse
|
6
|
Marín-Sáez J, Romero-González R, Garrido Frenich A. Reliable determination of tropane alkaloids in cereal based baby foods coupling on-line spe to mass spectrometry avoiding chromatographic step. Food Chem 2019; 275:746-753. [DOI: 10.1016/j.foodchem.2018.09.137] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Revised: 09/07/2018] [Accepted: 09/22/2018] [Indexed: 12/21/2022]
|
7
|
Monaci L, De Angelis E, Montemurro N, Pilolli R. Comprehensive overview and recent advances in proteomics MS based methods for food allergens analysis. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.06.016] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
8
|
Kaufmann A, Walker S. Comparison of linear intrascan and interscan dynamic ranges of Orbitrap and ion-mobility time-of-flight mass spectrometers. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2017; 31:1915-1926. [PMID: 28875592 DOI: 10.1002/rcm.7981] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Revised: 08/28/2017] [Accepted: 08/31/2017] [Indexed: 06/07/2023]
Abstract
RATIONALE The linear intrascan and interscan dynamic ranges of mass spectrometers are important in metabolome and residue analysis. A large linear dynamic range is mandatory if both low- and high-abundance ions have to be detected and quantitated in heavy matrix samples. These performance criteria, as provided by modern high-resolution mass spectrometry (HRMS), were systematically investigated. METHODS The comparison included two generations of Orbitraps, and an ion mobility quadrupole time-of-flight (QTOF) system In addition, different scan modes, as provided by the utilized instruments, were investigated. Calibration curves of different compounds covering a concentration range of five orders of magnitude were measured to evaluate the linear interscan dynamic range. The linear intrascan dynamic range and the resulting mass accuracy were evaluated by repeating these measurements in the presence of a very intense background. RESULTS Modern HRMS instruments can show linear dynamic ranges of five orders of magnitude. Often, however, the linear dynamic range is limited by the detection capability (sensitivity and selectivity) and by the electrospray ionization. Orbitraps, as opposed to TOF instruments, show a reduced intrascan dynamic range. This is due to the limited C-trap and Orbitrap capacity. The tested TOF instrument shows poorer mass accuracies than the Orbitraps. In contrast, hyphenation with an ion-mobility device seems not to affect the linear dynamic range. CONCLUSIONS The linear dynamic range of modern HRMS instrumentation has been significantly improved. This also refers to the virtual absence of systematic mass shifts at high ion abundances. The intrascan dynamic range of the current Orbitrap technology may still be a limitation when analyzing complex matrix extracts. On the other hand, the linear dynamic range is not only limited by the detector technology, but can also be shortened by peripheral devices, where the ionization and transfer of ions take place.
Collapse
Affiliation(s)
- Anton Kaufmann
- Official Food Control Authority, Fehrenstrasse 15, 8032, Zürich, Switzerland
| | - Stephan Walker
- Official Food Control Authority, Fehrenstrasse 15, 8032, Zürich, Switzerland
| |
Collapse
|
9
|
Bruns K, Mönnikes R, Lackner KJ. Quantitative determination of four immunosuppressants by high resolution mass spectrometry (HRMS). Clin Chem Lab Med 2017; 54:1193-200. [PMID: 26641969 DOI: 10.1515/cclm-2015-0863] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2015] [Accepted: 10/28/2015] [Indexed: 11/15/2022]
Abstract
BACKGROUND Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) utilizing triple-quadrupole instruments has been widely used for quantification of endogenous compounds, drugs or metabolites in clinical laboratories. In contrast, high-resolution mass spectrometry (HRMS) is typically used for compound identification due to its limited dynamic range. Recently HRMS instruments with enhanced linear dynamic range have become available. The aim of this study was to evaluate HRMS for fast quantitative applications in a clinical laboratory. METHODS A high throughput UPLC-TOF-MS assay for simultaneous quantification of cyclosporin A, tacrolimus, sirolimus and everolimus was developed. All immunosuppressants were analyzed as sodium adducts in TOF-only mode using an Agilent 6540 Q-TOF system. Extracted ion chromatograms of analytes and internal standards were created from full-scan data. The assay was evaluated and compared to an established LC-MS/MS assay according to CLSI recommendations. RESULTS The novel HRMS assay has a total run time of 3 min. The assay is linear in a clinical relevant concentration range for all four immunosupressants. Method correlations vs. established LC-MS/MS assay were between R2=0.99 and R2=0.97. Total coefficients of variation (CVT) ranges were 4.5%-6.4% (tacrolimus), 7.4%-8.0% (sirolimus), 8.0%-8.8% (everolimus) and 6.1%-7.4% (cyclosporine A) for three relevant concentration levels each. CONCLUSIONS High resolution TOF-MS and LC-MS/MS show equivalent quantitative performance for monitoring of cyclosporin A, tacrolimus, sirolimus and everolimus. HRMS has the potential to replace conventional LC-MS/MS in clinical laboratories because it simplifies assay development (no optimization of fragmentations and product ions necessary) and its full-scan data can provide additional information.
Collapse
|
10
|
Vergeynst L, K'oreje K, De Wispelaere P, Harinck L, Van Langenhove H, Demeestere K. Statistical procedures for the determination of linearity, detection limits and measurement uncertainty: A deeper look into SPE-LC-Orbitrap mass spectrometry of pharmaceuticals in wastewater. JOURNAL OF HAZARDOUS MATERIALS 2017; 323:2-10. [PMID: 27339948 DOI: 10.1016/j.jhazmat.2016.05.077] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2016] [Revised: 05/19/2016] [Accepted: 05/25/2016] [Indexed: 06/06/2023]
Abstract
This research addresses some critical challenges regarding the validation of a quantitative multi-residue method for pharmaceuticals in wastewater making use of modern SPE-LC-Orbitrap high-resolution mass spectrometry. Particular attention is given to study in detail response linearity, to realistically estimate detection limits, and to express the measurement precision of the analyte concentration, obtained by external calibration. First, linearity of the Orbitrap response showed to be matrix dependent in a counter intuitive way: stronger deviations from linearity were observed for pure solvent standards than for complex matrices like wastewater. Second, detection limits risk to be overestimated for ubiquitously present compounds for which true blank matrix samples are hard to find, leading to false negative findings. A novel and easy applicable methodology is presented to allow a better estimation of detection limits using the response of the natural isotopes. Third, a statistical methodology to estimate the measurement precision of the analyte concentration using basic validation parameters is developed specifically for the context of multi-residue quantification.
Collapse
Affiliation(s)
- Leendert Vergeynst
- Research Group Environmental Organic Chemistry and Technology (EnVOC), Department of Sustainable Organic Chemistry and Technology, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, B-9000 Ghent, Belgium
| | - Kenneth K'oreje
- Research Group Environmental Organic Chemistry and Technology (EnVOC), Department of Sustainable Organic Chemistry and Technology, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, B-9000 Ghent, Belgium
| | - Patrick De Wispelaere
- Research Group Environmental Organic Chemistry and Technology (EnVOC), Department of Sustainable Organic Chemistry and Technology, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, B-9000 Ghent, Belgium
| | - Lies Harinck
- Research Group Environmental Organic Chemistry and Technology (EnVOC), Department of Sustainable Organic Chemistry and Technology, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, B-9000 Ghent, Belgium
| | - Herman Van Langenhove
- Research Group Environmental Organic Chemistry and Technology (EnVOC), Department of Sustainable Organic Chemistry and Technology, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, B-9000 Ghent, Belgium
| | - Kristof Demeestere
- Research Group Environmental Organic Chemistry and Technology (EnVOC), Department of Sustainable Organic Chemistry and Technology, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, B-9000 Ghent, Belgium.
| |
Collapse
|
11
|
Moretti S, Cruciani G, Romanelli S, Rossi R, Saluti G, Galarini R. Multiclass method for the determination of 62 antibiotics in milk. JOURNAL OF MASS SPECTROMETRY : JMS 2016; 51:792-804. [PMID: 27490945 DOI: 10.1002/jms.3834] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2016] [Revised: 07/25/2016] [Accepted: 08/01/2016] [Indexed: 06/06/2023]
Abstract
A multiclass method for screening and confirmatory analysis of antimicrobial residues in milk has been developed and validated. Sixty-two antibiotics belonging to ten different drug families (amphenicols, cephalosporins, lincosamides, macrolides, penicillin, pleuromutilins, quinolones, rifamycins, sulfonamides and tetracyclines) have been included. After the addition of an aqueous solution of EDTA, the milk samples were extracted twice with acetonitrile, evaporated and dissolved in ammonium acetate. After centrifugation, 10 µl were analysed using LC-Q-Orbitrap operating in positive electrospray ionization mode. The method was validated in bovine milk in the range 2-150 µg kg(-1) for all antibiotics; for four compounds with maximum residue limits higher than 100 µg kg(-1) , the validation interval has been extended until 333 µg kg(-1) . The estimated performance characteristics were satisfactory complying with the requirements of Commission Decision 2002/657/EC. Good accuracies were obtained also taking advantage from the versatility of the hybrid mass analyser. Identification criteria were achieved verifying the mass accuracy and ion ratio of two ions, including the pseudomolecular one, where possible. Finally, the developed procedure was applied to 13 real cases of suspect milk samples (microbiological assay) confirming the presence of one or more antibiotics, although frequently, the maximum residue limits were not exceeded. The availability of rapid multiclass confirmatory methods can avoid wastes of suspect, but compliant, raw milk samples. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Simone Moretti
- Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche, Via G. Salvemini, 1, 06126, Perugia, Italy
| | - Gabriele Cruciani
- Department of Chemistry, Biology and Biotechnology, University of Perugia, Via Elce di Sotto 10, 06123, Perugia, Italy
| | - Sara Romanelli
- Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche, Via G. Salvemini, 1, 06126, Perugia, Italy
| | - Rosanna Rossi
- Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche, Via G. Salvemini, 1, 06126, Perugia, Italy
| | - Giorgio Saluti
- Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche, Via G. Salvemini, 1, 06126, Perugia, Italy
| | - Roberta Galarini
- Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche, Via G. Salvemini, 1, 06126, Perugia, Italy
| |
Collapse
|
12
|
Knolhoff AM, Croley TR. Non-targeted screening approaches for contaminants and adulterants in food using liquid chromatography hyphenated to high resolution mass spectrometry. J Chromatogr A 2015; 1428:86-96. [PMID: 26372444 DOI: 10.1016/j.chroma.2015.08.059] [Citation(s) in RCA: 84] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2015] [Revised: 08/14/2015] [Accepted: 08/27/2015] [Indexed: 12/22/2022]
Abstract
The majority of analytical methods for food safety monitor the presence of a specific compound or defined set of compounds. Non-targeted screening methods are complementary to these approaches by detecting and identifying unexpected compounds present in food matrices that may be harmful to public health. However, the development and implementation of generalized non-targeted screening workflows are particularly challenging, especially for food matrices due to inherent sample complexity and diversity and a large analyte concentration range. One approach that can be implemented is liquid chromatography coupled to high-resolution mass spectrometry, which serves to reduce this complexity and is capable of generating molecular formulae for compounds of interest. Current capabilities, strategies, and challenges will be reviewed for sample preparation, mass spectrometry, chromatography, and data processing workflows. Considerations to increase the accuracy and speed of identifying unknown molecular species will also be addressed, including suggestions for achieving sufficient data quality for non-targeted screening applications.
Collapse
Affiliation(s)
- Ann M Knolhoff
- U.S. Food and Drug Administration, Center for Food Safety and Applied Nutrition, 5100 Paint Branch Parkway, College Park, MD 20740, United States.
| | - Timothy R Croley
- U.S. Food and Drug Administration, Center for Food Safety and Applied Nutrition, 5100 Paint Branch Parkway, College Park, MD 20740, United States
| |
Collapse
|
13
|
Wu Y, Bi Y, Bingga G, Li X, Zhang S, Li J, Li H, Ding S, Xia X. Metabolomic analysis of swine urine treated with β2-agonists by ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry. J Chromatogr A 2015; 1400:74-81. [DOI: 10.1016/j.chroma.2015.04.050] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2015] [Revised: 04/17/2015] [Accepted: 04/23/2015] [Indexed: 11/30/2022]
|
14
|
Leendert V, Van Langenhove H, Demeestere K. Trends in liquid chromatography coupled to high-resolution mass spectrometry for multi-residue analysis of organic micropollutants in aquatic environments. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2015.01.010] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
15
|
Luz Gómez-Pérez M, Romero-González R, José Luis Martínez V, Garrido Frenich A. Analysis of pesticide and veterinary drug residues in baby food by liquid chromatography coupled to Orbitrap high resolution mass spectrometry. Talanta 2015; 131:1-7. [DOI: 10.1016/j.talanta.2014.07.066] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2014] [Revised: 07/18/2014] [Accepted: 07/21/2014] [Indexed: 11/30/2022]
|
16
|
Monaci L, Pilolli R, De Angelis E, Mamone G. Mass Spectrometry in Food Allergen Research. ADVANCED MASS SPECTROMETRY FOR FOOD SAFETY AND QUALITY 2015. [DOI: 10.1016/b978-0-444-63340-8.00007-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
17
|
Pilolli R, De Angelis E, Godula M, Visconti A, Monaci L. Orbitrap™ monostage MS versus hybrid linear ion trap MS: application to multi-allergen screening in wine. JOURNAL OF MASS SPECTROMETRY : JMS 2014; 49:1254-1263. [PMID: 25476943 DOI: 10.1002/jms.3453] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2014] [Revised: 07/24/2014] [Accepted: 07/31/2014] [Indexed: 06/04/2023]
Abstract
Food allergen research has made giant steps in the last years thanks to the features offered by the latest technology of mass analyzers placed on the market allowing multiplex sensitive detection of proteins. Potentials and features of two mass analyzers namely a linear ion trap capable of performing a data dependent or selected reaction monitoring analysis and an Orbitrap(TM) stand-alone MS enabling a broadband fragmentation without mass selection at highest mass resolving power are herein described and applied to the multiplex screening of allergens in a type of wine chosen as a reference matrix. Quantitative and confirmative capabilities of both platforms were assessed on the specific case study, the multiple detection of egg and milk -related proteins, typically employed in white wines as fining agents. Commercial bioinformatic tools used for a quick allergen identification will be also discussed.
Collapse
Affiliation(s)
- Rosa Pilolli
- Institute of Sciences of Food Production, National Research Council of Italy (ISPA-CNR), Via Amendola 122/O, 70126, Bari, Italy
| | | | | | | | | |
Collapse
|
18
|
Kaufmann A. Combining UHPLC and high-resolution MS: A viable approach for the analysis of complex samples? Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2014.06.025] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
19
|
Hird SJ, Lau BPY, Schuhmacher R, Krska R. Liquid chromatography-mass spectrometry for the determination of chemical contaminants in food. Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2014.04.005] [Citation(s) in RCA: 81] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
20
|
Validation of hepcidin quantification in plasma using LC-HRMS and discovery of a new hepcidin isoform. Bioanalysis 2014; 5:2509-20. [PMID: 24138624 DOI: 10.4155/bio.13.225] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND Hepcidin, a 25 amino acid peptide, plays an important role in iron homeostasis. Some hepcidin truncated peptides have antibiotic effects. RESULTS A new analytical method for hepcidin determination in human plasma using LC-HRMS operating in full-scan acquisition mode has been validated. The extraction consists of protein precipitation and a drying reconstitution step; a 2.1 x 50 mm (idxL) C18 analytical column was used. Detection specificity, stability, accuracy, precision and recoveries were determined. The LOQ/LOD were 0.25/0.1 nM, respectively. More than 600 injections of plasma extracts were performed, allowing evaluation of the assay robustness. Hepcidin-20, hepcidin-22 and a new isoform, hepcidin-24, were detected in patients. CONCLUSION The data underscore the usefulness of LC-HRMS for in-depth investigations related to hepcidin levels and pathways.
Collapse
|
21
|
Fu M, Xu W, Lu Q, Pan G, Varga C. Evaluation and optimization of high-performance liquid chromatography coupled with high-resolution mass spectrometry for phospholipid quantitation. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2014; 28:811-821. [PMID: 24573813 DOI: 10.1002/rcm.6835] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2013] [Revised: 01/06/2014] [Accepted: 01/10/2014] [Indexed: 06/03/2023]
Abstract
RATIONALE High-performance liquid chromatography coupled with high-resolution mass spectrometry (HPLC/HRMS) provides an attractive alternative to the traditional triple quadrupole mass spectrometry selected reaction monitoring (SRM) methodology in the field of quantitation. METHODS An LTQ Orbitrap Velos mass spectrometer coupled with a Shimadzu UHPLC system was used. A mass extraction window (MEW) was defined to mathematically correlate with mass resolving power (MRP). Five MRP measurement conditions at 7500, 15,000, 30,000, 60,000, and 100,000, and five MEW widths at 10%, 20%, 50%, and 100% of ±1000000/MRP, and were utilized as the experimental conditions. Comparison of profile and centroid algorithms was evaluated as well. RESULTS Selection of pH 8.5 buffer, C4 column, 20% IPA, and 10 ppm H3 PO4 , minimized hydrophobic and silanol interactions to enhance separation. Narrowing the MEW minimized background noise, while over-narrowing the MEW gave signal loss due to mass accuracy deviation. The mass accuracy deviation was larger for lower MRP measurements especially with centriod data, and hence a profile algorithm was recommended. The post-ionization signal suppression was observed with low MRP and was further confirmed with the analysis of multi-level linearity. CONCLUSIONS It was found that the HPLC/HRMS method with conditions of 20% ±1000000/MRP as MEW, 30,000 or 60,000 MRP, and profile algorithm, provide optimum results for quantitation of seven model phospholipids.
Collapse
Affiliation(s)
- Mingkun Fu
- Analytical Development Laboratories, Takeda Pharmaceutical International Co., 35 Landsdowne Street, Cambridge, MA, 02139, USA
| | | | | | | | | |
Collapse
|
22
|
Rubert J, León N, Sáez C, Martins CP, Godula M, Yusà V, Mañes J, Soriano JM, Soler C. Evaluation of mycotoxins and their metabolites in human breast milk using liquid chromatography coupled to high resolution mass spectrometry. Anal Chim Acta 2014; 820:39-46. [DOI: 10.1016/j.aca.2014.02.009] [Citation(s) in RCA: 66] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2013] [Revised: 01/29/2014] [Accepted: 02/06/2014] [Indexed: 10/25/2022]
|
23
|
Venable R, Haynes C, Cook JM. Reported prevalence and quantitative LC-MS methods for the analysis of veterinary drug residues in honey: a review. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2014; 31:621-40. [DOI: 10.1080/19440049.2014.886339] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
24
|
Eitzer BD, Hammack W, Filigenzi M. Interlaboratory comparison of a general method to screen foods for pesticides using QuEChERs extraction with high performance liquid chromatography and high resolution mass spectrometry. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2014; 62:80-87. [PMID: 24320559 DOI: 10.1021/jf405128y] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
An interlaboratory comparison of a multipesticide residue analytical method is reported. The goal of the comparison was to evaluate the potential for liquid chromatography/high resolution mass spectrometry along with a specific automated screening procedure to allow the determination of the presence or absence of a set of targeted compounds without additional manual review. The method utilized an off the shelf QuEChERs based extraction followed by analysis with an orbitrap mass spectrometer with the data evaluated by ToxID. The method was tested at three laboratories, with three produce matrices (spinach, carrots, and oranges), and three levels of spiked pesticides with all analyses in triplicate. A series of 247 compounds were tested, and it was found that the three laboratories produced consistent data; however, manual review was still necessary. The data was shown to have no false negatives for 211 compounds in the three produce matrixes at 200 ppb. Of these 211 compounds, 189 had no false negatives at 50 ppb, and 129 had no false negatives at 10 ppb. The HRMS method was shown to be robust with similar data being achieved by all three laboratories and detectable concentrations only slightly above the range shown for triple quadrupole MS/MS.
Collapse
Affiliation(s)
- Brian D Eitzer
- Department of Analytical Chemistry, The Connecticut Agricultural Experiment Station , 123 Huntington Street, New Haven, Connecticut 06511, United States
| | | | | |
Collapse
|
25
|
Fedorova G, Randak T, Lindberg RH, Grabic R. Comparison of the quantitative performance of a Q-Exactive high-resolution mass spectrometer with that of a triple quadrupole tandem mass spectrometer for the analysis of illicit drugs in wastewater. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2013; 27:1751-1762. [PMID: 23821568 DOI: 10.1002/rcm.6628] [Citation(s) in RCA: 69] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2013] [Revised: 05/10/2013] [Accepted: 05/13/2013] [Indexed: 06/02/2023]
Abstract
RATIONALE Analysis of drugs in wastewater is gaining more interest, as new approaches to estimate drug consumption from the amount of drug residues in wastewater have been proposed. The aim of this study was to compare the quantitative performance of high-resolution mass spectrometry with that of triple quadrupole mass spectrometry. METHODS A Q-Exactive mass spectrometer was operated in full scan (HRFS) (70 000 FWHM) and product scan (HRPS) (17 500 FWHM) modes. The first and third quadrupoles of the QqQ MS/MS instrument were operated at 0.7 FWHM. A mass-extracted window of 5 ppm around the theoretical m/z of each analyte was used to construct chromatograms. An HESI-II ion source was used for the ionization of target compounds. In-line-SPE-LC configuration was used for the extraction and separation of target analytes. RESULTS All three methods showed good linearity and repeatability. High-resolution detection of product ions exhibited better sensitivity and selectivity for some compounds. For most of the tested compounds, LOQs ranged from 0.46 to 20 ng L(-1) . Good agreement between measured and nominal concentrations was observed for most of the compounds at different levels of fortification. Both MS/MS methods showed good selectivity, while HRFS gave some false positive results. CONCLUSIONS The Q-Exactive mass spectrometer proved to be suitable for trace detection and quantification of most of the tested drugs in wastewater, with performance comparable to that of the commonly used MS/MS triple quadrupole, but with better selectivity.
Collapse
Affiliation(s)
- Ganna Fedorova
- University of South Bohemia in Ceske Budejovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zatisi 728/II, 389 25, Vodnany, Czech Republic.
| | | | | | | |
Collapse
|
26
|
Fragkaki AG, Georgakopoulos C, Sterk S, Nielen MWF. Sports doping: emerging designer and therapeutic β2-agonists. Clin Chim Acta 2013; 425:242-58. [PMID: 23954776 DOI: 10.1016/j.cca.2013.07.031] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2013] [Revised: 07/30/2013] [Accepted: 07/31/2013] [Indexed: 12/12/2022]
Abstract
Beta2-adrenergic agonists, or β2-agonists, are considered essential bronchodilator drugs in the treatment of bronchial asthma, both as symptom-relievers and, in combination with inhaled corticosteroids, as disease-controllers. The use of β2-agonists is prohibited in sports by the World Anti-Doping Agency (WADA) due to claimed anabolic effects, and also, is prohibited as growth promoters in cattle fattening in the European Union. This paper reviews the last seven-year (2006-2012) literature concerning the development of novel β2-agonists molecules either by modifying the molecule of known β2-agonists or by introducing moieties producing indole-, adamantyl- or phenyl urea derivatives. New emerging β2-agonists molecules for future therapeutic use are also presented, intending to emphasize their potential use for doping purposes or as growth promoters in the near future.
Collapse
Affiliation(s)
- A G Fragkaki
- Doping Control Laboratory of Athens, Olympic Athletic Center of Athens "Spyros Louis", Kifisias 37, 15123 Maroussi, Greece.
| | | | | | | |
Collapse
|
27
|
Kumar P, Rúbies A, Centrich F, Granados M, Cortés-Francisco N, Caixach J, Companyó R. Targeted analysis with benchtop quadrupole–orbitrap hybrid mass spectrometer: Application to determination of synthetic hormones in animal urine. Anal Chim Acta 2013; 780:65-73. [DOI: 10.1016/j.aca.2013.04.017] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2012] [Revised: 04/05/2013] [Accepted: 04/10/2013] [Indexed: 11/25/2022]
|
28
|
Abstract
High-resolution MS (HRMS) in conjunction with LC (LC–HRMS) has become available to many laboratories in the pharmaceutical industry. Due to its enhanced, though sometime perceived, specificity using the high-resolution power and its capability of simultaneous quantitation and structural elucidation using the post-acquisition data mining feature, utilization of LC–HRMS for bioanalysis could lead to potential rapid and reliable method development as well as sample analysis, thus generating both cost and resource savings. Here, we would like to share our perspectives about several current and future applications of LC–HRMS in bioanalysis. We will also discuss the factors influencing the quality of method establishment and potential pitfalls that need to be considered for the utilization of LC–HRMS in the field of regulated bioanalysis. We believe when utilized appropriately, LC–HRMS will play a significant role in the future landscape of quantitative bioanalysis.
Collapse
|
29
|
Bijlsma L, Emke E, Hernández F, de Voogt P. Performance of the linear ion trap Orbitrap mass analyzer for qualitative and quantitative analysis of drugs of abuse and relevant metabolites in sewage water. Anal Chim Acta 2013; 768:102-10. [DOI: 10.1016/j.aca.2013.01.010] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2012] [Revised: 01/03/2013] [Accepted: 01/05/2013] [Indexed: 10/27/2022]
|
30
|
Berendsen BJ, Stolker L(A, Nielen MW, Nielen MW. Selectivity in the sample preparation for the analysis of drug residues in products of animal origin using LC-MS. Trends Analyt Chem 2013. [DOI: 10.1016/j.trac.2012.09.019] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
31
|
Kaufmann A, Walker S. Evaluation of the interrelationship between mass resolving power and mass error tolerances for targeted bioanalysis using liquid chromatography coupled to high-resolution mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2013; 27:347-356. [PMID: 23239383 DOI: 10.1002/rcm.6454] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2012] [Revised: 10/24/2012] [Accepted: 10/25/2012] [Indexed: 06/01/2023]
Abstract
The determination of acceptable mass error tolerances for high-resolution mass spectrometry based signals has been evaluated in a comprehensive way. This was achieved by using a technical approach which is based on the post-column infusion of an analyte containing solution. This well-known experimental setup was not used to spot signal suppression regions of a particular analyte, but to spot regions of the chromatogram where a systematic mass drift of the analyte ion can be observed (isobaric interference plot). Not the changing signal intensity but the stability of the measured analyte mass was observed. A wide range of different analytes in combinations with potentially interfering matrices has been evaluated. Furthermore, different mass resolving power settings were evaluated. Isobaric interferences between matrix compounds and analytes were common at mass resolving powers <50,000 full width at half maximum. The proposed post-column infusion technique is a useful tool for the determination of the assay and matrix-specific mass error tolerances. It aims to ensure the highest possible selectivity, at the same time preventing the encounter of detrimental mass error related peak deformations as well as false negative findings. Unlike conventional matrix spiking approaches, isobaric interference plots provide information of potential interferences across the whole chromatographic time range. This becomes relevant when there is a relative retention time shift between the analyte and potential interfering matrix compounds. Furthermore, the described setup can be used to study how the mass accuracy of any mass spectrometer is affected by a widely varying total ion current.
Collapse
Affiliation(s)
- A Kaufmann
- Official Food Control Authority, Kantonales Labor Zürich, Fehrenstrasse 15, 8032 Zürich, Switzerland.
| | | |
Collapse
|
32
|
Combined data mining strategy for the systematic identification of sport drug metabolites in urine by liquid chromatography time-of-flight mass spectrometry. Anal Chim Acta 2013; 761:1-10. [DOI: 10.1016/j.aca.2012.11.049] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2012] [Revised: 11/16/2012] [Accepted: 11/25/2012] [Indexed: 11/24/2022]
|
33
|
Gallien S, Duriez E, Crone C, Kellmann M, Moehring T, Domon B. Targeted proteomic quantification on quadrupole-orbitrap mass spectrometer. Mol Cell Proteomics 2012; 11:1709-23. [PMID: 22962056 DOI: 10.1074/mcp.o112.019802] [Citation(s) in RCA: 375] [Impact Index Per Article: 31.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
There is an immediate need for improved methods to systematically and precisely quantify large sets of peptides in complex biological samples. To date protein quantification in biological samples has been routinely performed on triple quadrupole instruments operated in selected reaction monitoring mode (SRM), and two major challenges remain. Firstly, the number of peptides to be included in one survey experiment needs to be increased to routinely reach several hundreds, and secondly, the degree of selectivity should be improved so as to reliably discriminate the targeted analytes from background interferences. High resolution and accurate mass (HR/AM) analysis on the recently developed Q-Exactive mass spectrometer can potentially address these issues. This instrument presents a unique configuration: it is constituted of an orbitrap mass analyzer equipped with a quadrupole mass filter as the front-end for precursor ion mass selection. This configuration enables new quantitative methods based on HR/AM measurements, including targeted analysis in MS mode (single ion monitoring) and in MS/MS mode (parallel reaction monitoring). The ability of the quadrupole to select a restricted m/z range allows one to overcome the dynamic range limitations associated with trapping devices, and the MS/MS mode provides an additional stage of selectivity. When applied to targeted protein quantification in urine samples and benchmarked with the reference SRM technique, the quadrupole-orbitrap instrument exhibits similar or better performance in terms of selectivity, dynamic range, and sensitivity. This high performance is further enhanced by leveraging the multiplexing capability of the instrument to design novel acquisition methods and apply them to large targeted proteomic studies for the first time, as demonstrated on 770 tryptic yeast peptides analyzed in one 60-min experiment. The increased quality of quadrupole-orbitrap data has the potential to improve existing protein quantification methods in complex samples and address the pressing demand of systems biology or biomarker evaluation studies.
Collapse
Affiliation(s)
- Sebastien Gallien
- Luxembourg Clinical Proteomics Center (LCP), CRP-Santé, L-1445 Strassen, Luxembourg
| | | | | | | | | | | |
Collapse
|
34
|
ter Laak TL, Puijker LM, van Leerdam JA, Raat KJ, Kolkman A, de Voogt P, van Wezel AP. Broad target chemical screening approach used as tool for rapid assessment of groundwater quality. THE SCIENCE OF THE TOTAL ENVIRONMENT 2012; 427-428:308-313. [PMID: 22551937 DOI: 10.1016/j.scitotenv.2012.04.013] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2011] [Revised: 03/31/2012] [Accepted: 04/04/2012] [Indexed: 05/31/2023]
Abstract
The chemical water quality is often assessed by screening for a limited set of target chemicals. This 'conventional' target analysis approach inevitably misses chemicals present in the samples. In this study a 'broad' target screening approach for water quality assessment using high resolution and accurate mass spectrometry (HR MS) was applied to detect a wide variety of organic chemicals in 42 groundwater samples. In this approach, both known and unidentified chemicals observed in previous samples define the training set for the analysis of future samples and, additionally, new samples can be used to extend the training set. Nearly 400 chemicals were observed in the samples, of which 82 were known and more than 313 are of unknown identity. The obtained results were interpreted in relation to the source characteristics and land use. Groundwater that was affected by landfills showed the highest total MS response (ion counts) and most individual chemicals and was therefore considered most contaminated. Furthermore, river bank filtrated water was generally more contaminated than phreatic groundwater and groundwater from (semi)confined aquifers was most pristine. Additionally, industrial chemicals were more frequently observed in river bank filtrated water and pesticides were more frequently observed in water originating from rural areas. The 'broad' target screening approach for both known and unidentified chemicals does provide more information on the over-all water quality than 'conventional' target analysis.
Collapse
Affiliation(s)
- Thomas L ter Laak
- KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB, Nieuwegein, The Netherlands.
| | | | | | | | | | | | | |
Collapse
|
35
|
Kaufmann A, Walker S. Accuracy of relative isotopic abundance and mass measurements in a single-stage orbitrap mass spectrometer. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2012; 26:1081-1090. [PMID: 22467458 DOI: 10.1002/rcm.6195] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Orbitrap technology offers a combination of different technical specifications which have not yet been achieved by other high-resolution mass spectrometry instrumentation. This refers to the combination of sensitivity, dynamic range, mass accuracy, resolution and speed. The high stability of the mass axis and the general ease of use made the orbitrap instrumentation attractive for routine laboratories. However, there are circumstances where significantly deviating relative isotopic abundance (RIA) and shifting accurate masses can be observed. RIA becomes biased at low ion counts. Furthermore, two adjacent, only partially resolved near-isobaric ions are detected with a deviating RIA. The presence of a very intensive mass peak does not only induce Fourier transformation related artefacts (side-lobes) but can cause mass shifts of small adjacent near-isobaric mass peaks. These effects are not as drastic as known for Fourier transform ion cyclotron resonance instruments. Still, users trying to identify or quantify trace level compounds should be aware about such limitations in order to avoid possible pitfalls.
Collapse
Affiliation(s)
- A Kaufmann
- Official Food Control Authority, Fehrenstrasse 15, 8032, Zürich, Switzerland.
| | | |
Collapse
|
36
|
Ouerdane L, Meija J, Bakirdere S, Yang L, Mester Z. Nonlinear Signal Response in Electrospray Mass Spectrometry: Implications for Quantitation of Arsenobetaine Using Stable Isotope Labeling by Liquid Chromatography and Electrospray Orbitrap Mass Spectrometry. Anal Chem 2012; 84:3958-64. [DOI: 10.1021/ac203137n] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Laurent Ouerdane
- Institute for National Measurement
Standards, National Research Council Canada, Ottawa, ON K1A 0R6, Canada
- Laboratoire de Chimie Analytique
Bio-Inorganique et Environnement, IPREM, Université de Pau et des pays de l’Adour/CNRS UMR 5254,
Hélioparc, 2 Avenue du Pr. Angot, 64000 Pau, France
| | - Juris Meija
- Institute for National Measurement
Standards, National Research Council Canada, Ottawa, ON K1A 0R6, Canada
| | - Sezgin Bakirdere
- Institute for National Measurement
Standards, National Research Council Canada, Ottawa, ON K1A 0R6, Canada
- Department of Chemistry, Middle East Technical University, 06531 Ankara, Turkey
- Department of Science Education, Yıldız Technical University, 34220, İstanbul,
Turkey
| | - Lu Yang
- Institute for National Measurement
Standards, National Research Council Canada, Ottawa, ON K1A 0R6, Canada
| | - Zoltán Mester
- Institute for National Measurement
Standards, National Research Council Canada, Ottawa, ON K1A 0R6, Canada
| |
Collapse
|
37
|
Henry H, Sobhi HR, Scheibner O, Bromirski M, Nimkar SB, Rochat B. Comparison between a high-resolution single-stage Orbitrap and a triple quadrupole mass spectrometer for quantitative analyses of drugs. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2012; 26:499-509. [PMID: 22302489 DOI: 10.1002/rcm.6121] [Citation(s) in RCA: 106] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
The capabilities of a high-resolution (HR), accurate mass spectrometer (Exactive-MS) operating in full scan MS mode was investigated for the quantitative LC/MS analysis of drugs in patients' plasma samples. A mass resolution of 50,000 (FWHM) at m/z 200 and a mass extracted window of 5 ppm around the theoretical m/z of each analyte were used to construct chromatograms for quantitation. The quantitative performance of the Exactive-MS was compared with that of a triple quadrupole mass spectrometer (TQ-MS), TSQ Quantum Discovery or Quantum Ultra, operating in the conventional selected reaction monitoring (SRM) mode. The study consisted of 17 therapeutic drugs including 8 antifungal agents (anidulafungin, caspofungin, fluconazole, itraconazole, hydroxyitraconazole posaconazole, voriconazole and voriconazole-N-oxide), 4 immunosuppressants (ciclosporine, everolimus, sirolimus and tacrolimus) and 5 protein kinase inhibitors (dasatinib, imatinib, nilotinib, sorafenib and sunitinib). The quantitative results obtained with HR-MS acquisition show comparable detection specificity, assay precision, accuracy, linearity and sensitivity to SRM acquisition. Importantly, HR-MS offers several benefits over TQ-MS technology: absence of SRM optimization, time saving when changing the analysis from one MS to another, more complete information of what is in the samples and easier troubleshooting. Our work demonstrates that U/HPLC coupled to Exactive HR-MS delivers comparable results to TQ-MS in routine quantitative drug analyses. Considering the advantages of HR-MS, these results suggest that, in the near future, there should be a shift in how routine quantitative analyses of small molecules, particularly for therapeutic drugs, are performed.
Collapse
Affiliation(s)
- Hugues Henry
- Clinical Chemistry, University Hospital of Lausanne; CHUV, 1011, Lausanne, Switzerland
| | | | | | | | | | | |
Collapse
|
38
|
Accurate mass screening of pharmaceuticals and fungicides in water by U-HPLC–Exactive Orbitrap MS. Anal Bioanal Chem 2012; 403:2997-3011. [DOI: 10.1007/s00216-012-5888-8] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2011] [Revised: 02/11/2012] [Accepted: 02/20/2012] [Indexed: 11/25/2022]
|
39
|
Meyer MR, Maurer HH. Current applications of high-resolution mass spectrometry in drug metabolism studies. Anal Bioanal Chem 2012; 403:1221-31. [DOI: 10.1007/s00216-012-5807-z] [Citation(s) in RCA: 69] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2011] [Accepted: 01/28/2012] [Indexed: 12/31/2022]
|
40
|
Kaufmann A. High Mass Resolution Versus MS/MS. TOF-MS WITHIN FOOD AND ENVIRONMENTAL ANALYSIS - COMPREHENSIVE ANALYTICAL CHEMISTRY 2012. [DOI: 10.1016/b978-0-444-53810-9.00001-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
41
|
Kaufmann A. The current role of high-resolution mass spectrometry in food analysis. Anal Bioanal Chem 2011; 403:1233-49. [PMID: 22179491 DOI: 10.1007/s00216-011-5629-4] [Citation(s) in RCA: 151] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2011] [Revised: 11/28/2011] [Accepted: 11/29/2011] [Indexed: 11/26/2022]
Abstract
High-resolution mass spectrometry (HRMS), which is used for residue analysis in food, has gained wider acceptance in the last few years. This development is due to the availability of more rugged, sensitive, and selective instrumentation. The benefits provided by HRMS over classical unit-mass-resolution tandem mass spectrometry are considerable. These benefits include the collection of full-scan spectra, which provides greater insight into the composition of a sample. Consequently, the analyst has the freedom to measure compounds without previous compound-specific tuning, the possibility of retrospective data analysis, and the capability of performing structural elucidations of unknown or suspected compounds. HRMS strongly competes with classical tandem mass spectrometry in the field of quantitative multiresidue methods (e.g., pesticides and veterinary drugs). It is one of the most promising tools when moving towards nontargeted approaches. Certain hardware and software issues still have to be addressed by the instrument manufacturers for it to dislodge tandem mass spectrometry from its position as the standard trace analysis tool.
Collapse
|
42
|
Liu X, Yang J, Li J, Li X, Li J, Lu X, Shen J, Wang Y, Zhang Z. Analysis of water-soluble azo dyes in soft drinks by high resolution UPLC–MS. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2011; 28:1315-23. [DOI: 10.1080/19440049.2011.604795] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
|
43
|
Quantification of anthelmintic drug residues in milk and muscle tissues by liquid chromatography coupled to Orbitrap and liquid chromatography coupled to tandem mass spectrometry. Talanta 2011; 85:991-1000. [PMID: 21726729 DOI: 10.1016/j.talanta.2011.05.009] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2011] [Revised: 05/03/2011] [Accepted: 05/05/2011] [Indexed: 11/22/2022]
Abstract
A simple method for the determination of some anthelmintic drugs and phenylbutazone residues in milk and muscle was developed. Following a fast and easy extraction and evaporation procedure, the extract was injected into an ultra performance liquid chromatography system coupled to a single stage Orbitrap detector. The high mass resolution of 50,000 full width at half maximum and corresponding narrow mass windows permitted a very selective and sensitive detection of analytes without requiring fragmentation of the observed [M+H](+) or [M+Na](+) ions. This eliminated some difficulties which have plagued the analysis of compounds belonging to the group of avermectins. The analytical method was validated according to the EU commission decision for Orbitrap based, but also for more traditional tandem mass spectrometry based detection and quantification. Equal repeatability but significantly higher sensitivity for critical compounds (avermectins) was obtained for the Orbitrap based detection. A result of this study was the conclusion that analytes with poor fragmentation properties (e.g. sodium-cationized molecules) can be more easily quantified by single stage high resolution mass spectrometry than by tandem mass spectrometry.
Collapse
|
44
|
Kaufmann A, Butcher P, Maden K, Walker S, Widmer M. Quantitative and confirmative performance of liquid chromatography coupled to high-resolution mass spectrometry compared to tandem mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2011; 25:979-92. [PMID: 21416536 DOI: 10.1002/rcm.4952] [Citation(s) in RCA: 71] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2010] [Revised: 01/17/2011] [Accepted: 01/22/2011] [Indexed: 05/21/2023]
Abstract
The quantitative and confirmative performance of two different mass spectrometry (MS) techniques (high-resolution MS and tandem MS) was critically compared. Evaluated was a new extraction and clean-up protocol which was developed to cover more than 100 different veterinary drugs at trace levels in a number of animal tissues and honey matrices. Both detection techniques, high-resolution mass spectrometry (HRMS) (single-stage Orbitrap instrument operated at 50 000 full width at half maximum) and tandem mass spectrometry (MS/MS) (quadrupole technology) were used to validate the method according to the EU Commission Decision 2002/657/EEC. Equal or even a slightly better quantitative performance was observed for the HRMS-based approach. Sensitivity is higher for unit mass resolution MS/MS if only a subset of the 100 compounds has to be monitored. Confirmation of suspected positive findings can be done by evaluating the intensity ratio between different MS/MS transitions, or by accurate mass based product ion traces (no precursor selection applied). MS/MS relies on compound-specific optimized transitions; hence the second, confirmatory transition generally shows relatively high ion abundance (fragmentation efficacy). This is often not the case in single-stage HRMS, since a generic (not compound-optimized) collision energy is applied. Hence, confirmation of analytes present at low levels is superior when performed by MS/MS. Slightly better precision, but poorer accuracy (fortified matrix extracts versus pure standard solution) of ion ratios were observed when comparing data obtained by HRMS versus MS/MS.
Collapse
Affiliation(s)
- Anton Kaufmann
- Official Food Control Authority, Fehrenstrasse 15, 8032 Zürich, Switzerland.
| | | | | | | | | |
Collapse
|
45
|
Kaufmann A, Butcher P, Maden K, Walker S, Widmer M. Development of an improved high resolution mass spectrometry based multi-residue method for veterinary drugs in various food matrices. Anal Chim Acta 2010; 700:86-94. [PMID: 21742121 DOI: 10.1016/j.aca.2010.11.034] [Citation(s) in RCA: 113] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2010] [Revised: 11/15/2010] [Accepted: 11/18/2010] [Indexed: 11/17/2022]
Abstract
Multi-residue methods for veterinary drugs or pesticides in food are increasingly often based on ultra performance liquid chromatography (UPLC) coupled to high resolution mass spectrometry (HRMS). Previous available time of flight (TOF) technologies, showing resolutions up to 15,000 full width at half maximum (FWHM), were not sufficiently selective for monitoring low residue concentrations in difficult matrices (e.g. hormones in tissue or antibiotics in honey). The approach proposed in this paper is based on a single stage Orbitrap mass spectrometer operated at 50,000 FWHM. Extracts (liver and kidney) which were produced according to a validated multi-residue method (time of flight detection based) could not be analyzed by Orbitrap because of extensive signal suppression. This required the improvement of established extraction and clean-up procedures. The introduced, more extensive deproteinzation steps and dedicated instrumental settings successfully eliminated these detrimental suppression effects. The reported method, covering more than 100 different veterinary dugs, was validated according to the EU Commission Decision 2002/657/EEC. Validated matrices include muscle, kidney, liver, fish and honey. Significantly better performance parameters (e.g. linearity, reproducibility and detection limits) were obtained when comparing the new method with the older, TOF based method. These improvements are attributed to the higher resolution (50,000 versus 12,000 FWHM) and the superior mass stability of the of the Orbitrap over the previously utilized TOF instrument.
Collapse
Affiliation(s)
- A Kaufmann
- Official Food Control Authority, Zürich, Switzerland.
| | | | | | | | | |
Collapse
|