1
|
Sanchez M, Berveiller P, Behal H, Tursack A, Plurien A, Ghesquière L, Garabedian C. Impact of body mass index on sonographic measurement of head perineum distance before operative vaginal delivery. Int J Gynaecol Obstet 2024. [PMID: 38736297 DOI: 10.1002/ijgo.15568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2024] [Revised: 04/14/2024] [Accepted: 04/20/2024] [Indexed: 05/14/2024]
Abstract
OBJECTIVE To evaluate the impact of body mass index (BMI) on sonographic measurement of head perineum distance (HPD) before operative vaginal delivery (OVD). METHODS This was a single-center retrospective cohort study (Lille, France) conducted from March 1, 2019 to October 31, 2020 including all singleton and OVD. HPD measurement was systematically performed without and with compression on the perineum soft tissues. The level of station was defined by vaginal examination and three maternal BMI groups were defined (normal BMI [<24.9 kg/m2] vs overweight [25-29.9 kg/m2] vs obese [≥30 kg/m2]). HPD measures were compared between BMI groups and compression, in distinct level of station, using a two-factor analysis of variance including BMI groups, the compression, and the interaction term BMI group compression. RESULTS A total of 775 women were included: 488 with normal BMI, 181 overweight patients and 106 obese patients. The measurement of HPD before OVD without and with compression on the soft tissues was significantly different between the BMI groups only in the lower part, particularly between normal BMI and obese patients (mean difference (95% CI): 6.6 mm (4.0 to 9.2) without compression; 3.8 (1.1 to 6.4) with compression). CONCLUSION The values of HPD without and with compression on the soft tissues on the maternal perineum were different according to the maternal BMI concerning lower part station. Thus, it seems important to define thresholds of HPD measures corresponding to each head station levels according to maternal BMI.
Collapse
Affiliation(s)
| | - Paul Berveiller
- Department of Gynecology and Obstetrics, Poissy-Saint Germain Hospital, Poissy, France
- UMR 1198-BREED, RHuMA, INRAE, Paris Saclay University, Montigny-Le-Bretonneux, France
| | - Hélène Behal
- Department of Biostatistics, CHU Lille, Lille, France
| | | | - Alix Plurien
- Department of Obstetrics, CHU Lille, Lille, France
| | - Louise Ghesquière
- Department of Obstetrics, CHU Lille, Lille, France
- ULR 2694-METRICS: Health Technology and Medical Practice Assessment, University of Lille, Lille, France
| | - Charles Garabedian
- Department of Obstetrics, CHU Lille, Lille, France
- ULR 2694-METRICS: Health Technology and Medical Practice Assessment, University of Lille, Lille, France
| |
Collapse
|
2
|
Eggebø TM, Hjartardottir H. Descent of the presenting part assessed with ultrasound. Am J Obstet Gynecol 2024; 230:S901-S912. [PMID: 34461079 DOI: 10.1016/j.ajog.2021.08.030] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Revised: 08/15/2021] [Accepted: 08/19/2021] [Indexed: 11/29/2022]
Abstract
Fetal head descent can be expressed as fetal station and engagement. Station is traditionally based on clinical vaginal examination of the distal part of the fetal skull and related to the level of the ischial spines. Engagement is based on a transabdominal examination of the proximal part of the fetal head above the pelvic inlet. Clinical examinations are subjective, and objective measurements of descent are warranted. Ultrasound is a feasible diagnostic tool in labor, and fetal lie, station, position, presentation, and attitude can be examined. This review presents an overview of fetal descent examined with ultrasound. Ultrasound was first introduced for examining fetal descent in 1977. The distance from the sacral tip to the fetal skull was measured with A-mode ultrasound, but more convenient transperineal methods have since been published. Of those, progression distance, angle of progression, and head-symphysis distance are examined in the sagittal plane, using the inferior part of the symphysis pubis as reference point. Head-perineum distance is measured in the frontal plane (transverse transperineal scan) as the shortest distance from perineum to the fetal skull, representing the remaining part of the birth canal for the fetus to pass. At high stations, the fetal head is directed downward, followed with a horizontal and then an upward direction when the fetus descends in the birth canal and deflexes the head. Head descent may be assessed transabdominally with ultrasound and measured as the suprapubic descent angle. Many observational studies have shown that fetal descent assessed with ultrasound can predict labor outcome before induction of labor, as an admission test, and during the first and second stage of labor. Labor progress can also be examined longitudinally. The International Society of Ultrasound in Obstetrics and Gynecology recommends using ultrasound in women with prolonged or arrested first or second stage of labor, when malpositions or malpresentations are suspected, and before an operative vaginal delivery. One single ultrasound parameter cannot tell for sure whether an instrumental delivery is going to be successful. Information about station and position is a prerequisite, but head direction, presentation, and attitude also should be considered.
Collapse
Affiliation(s)
- Torbjørn M Eggebø
- National Center for Fetal Medicine, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway; Department of Clinical and Molecular Medicine, Norwegian University of Science and Technology, Trondheim, Norway; Department of Obstetrics and Gynecology, Helse Stavanger, Stavanger University Hospital, Stavanger, Norway.
| | - Hulda Hjartardottir
- Department of Obstetrics and Gynecology, Landspitali University Hospital, Reykjavík, Iceland; Faculty of Medicine, University of Iceland, Reykjavík, Iceland
| |
Collapse
|
3
|
Romero R, Sabo Romero V, Kalache KD, Stone J. Parturition at term: induction, second and third stages of labor, and optimal management of life-threatening complications-hemorrhage, infection, and uterine rupture. Am J Obstet Gynecol 2024; 230:S653-S661. [PMID: 38462251 DOI: 10.1016/j.ajog.2024.02.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/12/2024]
Abstract
Childbirth is a defining moment in anyone's life, and it occurs 140 million times per year. Largely a physiologic process, parturition does come with risks; one mother dies every two minutes. These deaths occur mostly among healthy women, and many are considered preventable. For each death, 20 to 30 mothers experience complications that compromise their short- and long-term health. The risk of birth extends to the newborn, and, in 2020, 2.4 million neonates died, 25% in the first day of life. Hence, intrapartum care is an important priority for society. The American Journal of Obstetrics & Gynecology has devoted two special Supplements in 2023 and 2024 to the clinical aspects of labor at term. This article describes the content of the Supplements and highlights new developments in the induction of labor (a comparison of methods, definition of failed induction, new pharmacologic agents), management of the second stage, the value of intrapartum sonography, new concepts on soft tissue dystocia, optimal care during the third stage, and common complications that account for maternal death, such as infection, hemorrhage, and uterine rupture. All articles are available to subscribers and non-subscribers and have supporting video content to enhance dissemination and improve intrapartum care. Our hope is that no mother suffers because of lack of information.
Collapse
Affiliation(s)
- Roberto Romero
- Pregnancy Research Branch, Division of Obstetrics and Maternal-Fetal Medicine, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, US Department of Health and Human Services, Bethesda, MD; Department of Obstetrics and Gynecology, University of Michigan, Ann Arbor, MI; Department of Epidemiology and Biostatistics, Michigan State University, East Lansing, MI.
| | | | - Karim D Kalache
- Department of Clinical Obstetrics and Gynecology, Weill Cornell Medical College-Qatar Division, Doha, Qatar; Division of Maternal-Fetal Medicine, Women's Services, Sidra Medicine, Doha, Qatar
| | - Joanne Stone
- Department of Obstetrics and Gynecology, Icahn School of Medicine at Mount Sinai, New York, NY
| |
Collapse
|
4
|
Mitta K, Tsakiridis I, Dagklis T, Kalogiannidis I, Mamopoulos A, Michos G, Virgiliou A, Athanasiadis A. Ultrasonographic Evaluation of the Second Stage of Labor according to the Mode of Delivery: A Prospective Study in Greece. J Clin Med 2024; 13:1068. [PMID: 38398380 PMCID: PMC10889379 DOI: 10.3390/jcm13041068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 02/07/2024] [Accepted: 02/12/2024] [Indexed: 02/25/2024] Open
Abstract
BACKGROUND AND OBJECTIVES Accurate diagnosis of labor progress is crucial for making well-informed decisions regarding timely and appropriate interventions to optimize outcomes for both the mother and the fetus. The aim of this study was to assess the progress of the second stage of labor using intrapartum ultrasound. MATERIAL AND METHODS This was a prospective study (December 2022-December 2023) conducted at the Third Department of Obstetrics and Gynecology, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, Greece. Maternal-fetal and labor characteristics were recorded, and two ultrasound parameters were measured: the angle of progression (AoP) and the head-perineum distance (HPD). The correlation between the two ultrasonographic values and the maternal-fetal characteristics was investigated. Multinomial regression analysis was also conducted to investigate any potential predictors of the mode of delivery. RESULTS A total of 82 women at the second stage of labor were clinically and sonographically assessed. The mean duration of the second stage of labor differed between vaginal and cesarean deliveries (65.3 vs. 160 min; p-value < 0.001) and between cesarean and operative vaginal deliveries (160 vs. 88.6 min; p-value = 0.015). The occiput anterior position was associated with an increased likelihood of vaginal delivery (OR: 24.167; 95% CI: 3.8-152.5; p-value < 0.001). No significant differences were identified in the AoP among the three different modes of delivery (vaginal: 145.7° vs. operative vaginal: 139.9° vs. cesarean: 132.1°; p-value = 0.289). The mean HPD differed significantly between vaginal and cesarean deliveries (28.6 vs. 41.4 mm; p-value < 0.001) and between cesarean and operative vaginal deliveries (41.4 vs. 26.9 mm; p-value = 0.002); it was correlated significantly with maternal BMI (r = 0.268; p-value = 0.024) and the duration of the second stage of labor (r = 0.256; p-value = 0.031). Low parity (OR: 12.024; 95% CI: 6.320-22.876; p-value < 0.001) and high HPD (OR: 1.23; 95% CI: 1.05-1.43; p-value = 0.007) were found to be significant predictors of cesarean delivery. CONCLUSIONS The use of intrapartum ultrasound as an adjunctive technique to the standard clinical evaluation may enhance the diagnostic approach to an abnormal labor progress and predict the need for operative vaginal or cesarean delivery.
Collapse
Affiliation(s)
| | - Ioannis Tsakiridis
- Third Department of Obstetrics and Gynecology, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, 54642 Thessaloniki, Greece; (K.M.); (T.D.); (I.K.); (A.M.); (G.M.); (A.V.); (A.A.)
| | | | | | | | | | | | | |
Collapse
|
5
|
Enomoto N, Maki S, Nii M, Yamaguchi M, Tamaishi Y, Takakura S, Magawa S, Tanaka K, Tanaka H, Kondo E, Katsuragi S, Ikeda T. Accurate evaluation of the progress of delivery with transperineal ultrasound may improve vaginal delivery: a single-center retrospective study. Sci Rep 2023; 13:20945. [PMID: 38016993 PMCID: PMC10684555 DOI: 10.1038/s41598-023-47457-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Accepted: 11/14/2023] [Indexed: 11/30/2023] Open
Abstract
Although digital examination of the cervix is the standard method used worldwide for evaluating the progress of delivery, it is subjective. Transperineal ultrasound (TPU) is combined with digital evaluation for accurate assessment of fetal descent and rotation of the advanced part of the fetus. This retrospective study aimed to clarify the impact of introducing TPU on perinatal outcomes at Mie University Hospital. We analyzed singleton pregnant women who underwent delivery management at our hospital between April 2020 and March 2021. Perinatal outcomes were compared between patients who used TPU (TPU+ group) and those who did not (TPU- group). The angle of progression and head direction were measured. The rate of vaginal delivery was significantly increased (90.9% vs. 71.6%; P = 0.0017), and the second stage of labor was significantly prolonged in the TPU+ group (148.1 vs. 75.8 min; P < 0.0001). A significant difference was observed in termination in the latent phase between the TPU+ group [3/8 (37.5%) cases] and TPU- group [20/25 (80.0%) cases] (P = 0.036). The rate of vaginal delivery can be increased through accurate evaluation of the progress of delivery with TPU.
Collapse
Affiliation(s)
- Naosuke Enomoto
- Department of Obstetrics and Gynecology, Matsusaka Chuo General Hospital, 102 Kawaimachi, Matsusaka, Mie, Japan.
- Department of Obstetrics and Gynecology, Mie University Faculty of Medicine, Mie, Japan.
| | - Shintaro Maki
- Department of Obstetrics and Gynecology, Mie University Faculty of Medicine, Mie, Japan
| | - Masafumi Nii
- Department of Obstetrics and Gynecology, Mie University Faculty of Medicine, Mie, Japan
| | - Mizuki Yamaguchi
- Department of Obstetrics and Gynecology, Mie University Faculty of Medicine, Mie, Japan
| | - Yuya Tamaishi
- Department of Obstetrics and Gynecology, Mie University Faculty of Medicine, Mie, Japan
| | - Sho Takakura
- Department of Obstetrics and Gynecology, Mie University Faculty of Medicine, Mie, Japan
| | - Shoichi Magawa
- Department of Obstetrics and Gynecology, Mie University Faculty of Medicine, Mie, Japan
| | - Kayo Tanaka
- Department of Obstetrics and Gynecology, Mie University Faculty of Medicine, Mie, Japan
| | - Hiroaki Tanaka
- Department of Obstetrics and Gynecology, Mie University Faculty of Medicine, Mie, Japan
| | - Eiji Kondo
- Department of Obstetrics and Gynecology, Mie University Faculty of Medicine, Mie, Japan
| | - Shinji Katsuragi
- Department of Obstetrics and Gynecology, Faculty of Medicine, University of Miyazaki, Miyazaki, Japan
| | - Tomoaki Ikeda
- Department of Obstetrics and Gynecology, Mie University Faculty of Medicine, Mie, Japan
| |
Collapse
|
6
|
Eggebø TM, Benediktsdottir S, Hjartardottir H, Salvesen KÅ, Volløyhaug I. Ultrasound examination of the pelvic floor during active labor: A longitudinal cohort study. Acta Obstet Gynecol Scand 2023; 102:1203-1209. [PMID: 37417688 PMCID: PMC10407019 DOI: 10.1111/aogs.14620] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 05/09/2023] [Accepted: 06/11/2023] [Indexed: 07/08/2023]
Abstract
INTRODUCTION There is limited evidence about changes in the pelvic floor during active labor. We aimed to investigate changes in hiatal dimensions during the active first stage of labor and associations with fetal descent and head position. MATERIAL AND METHODS We conducted a longitudinal, prospective cohort study at the National University Hospital of Iceland, from 2016 to 2018. Nulliparous women with spontaneous onset of labor, a single fetus in cephalic presentation, and gestational age ≥37 weeks were eligible. Fetal position was assessed with transabdominal ultrasound and fetal descent was measured with transperineal ultrasound. Three-dimensional volumes were acquired from transperineal scanning at the start of the active phase of labor and in late first stage or early second stage. The largest transverse hiatal diameter was measured in the plane of minimal hiatal dimensions. The levator urethral gap was measured as the distance between the center of the urethra and the levator insertion using tomographic ultrasound imaging. Measurements of the levator urethral gap were made in the plane of minimal hiatal dimensions and 2.5 and 5 mm cranial to this. RESULTS The final study population comprised 78 women. The mean transverse hiatal diameter increased 12.4% between the two examinations, from 39.4 ± 4.1 mm (±standard deviation) at the first examination to 44.3 ± 5.8 mm at the last examination (p < 0.01). We found a moderate correlation between the transverse hiatal diameter and fetal station at the last examination (r = 0.44, r2 = 0.19; p < 0.01; regression equation y = 2.71 + 0.014x), and a weak correlation between the change in transverse hiatal diameter and change in fetal station (r = 0.29; r2 = 0.08; p = 0.01; regression equation y = 0.24 + 0.012x). Levator urethral gap increased significantly in all three planes on both the left and right sides. Head position was not associated with hiatal measurements after adjusting for fetal station. CONCLUSIONS We found a significant, but only modest, increase of the hiatal dimensions during the first stage of labor. The risk of levator ani trauma will therefore be low during this stage. The change in transverse hiatal diameter was associated with fetal descent but not with head position.
Collapse
Affiliation(s)
- Torbjørn M. Eggebø
- National Center for Fetal MedicineTrondheim University Hospital (St. Olavs Hospital)TrondheimNorway
- Institute of Clinical and Molecular MedicineNorwegian University of Science and TechnologyTrondheimNorway
- Department of Obstetrics and GynecologyStavanger University HospitalStavangerNorway
| | | | - Hulda Hjartardottir
- Department of Obstetrics and GynecologyLandspitali University HospitalReykjavikIceland
| | - Kjell Å. Salvesen
- National Center for Fetal MedicineTrondheim University Hospital (St. Olavs Hospital)TrondheimNorway
- Institute of Clinical and Molecular MedicineNorwegian University of Science and TechnologyTrondheimNorway
| | - Ingrid Volløyhaug
- Institute of Clinical and Molecular MedicineNorwegian University of Science and TechnologyTrondheimNorway
- Department of Obstetrics and GynecologyTrondheim University Hospital (St. Olavs Hospital)TrondheimNorway
| |
Collapse
|
7
|
Usman S, Hanidu A, Kovalenko M, Hassan WA, Lees C. The sonopartogram. Am J Obstet Gynecol 2023; 228:S997-S1016. [PMID: 37164504 DOI: 10.1016/j.ajog.2022.06.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Revised: 06/15/2022] [Accepted: 06/16/2022] [Indexed: 03/17/2023]
Abstract
The assessment of labor progress from digital vaginal examination has remained largely unchanged for at least a century, despite the current major advances in maternal and perinatal care. Although inconsistently reproducible, the findings from digital vaginal examination are customarily plotted manually on a partogram, which is composed of a graphical representation of labor, together with maternal and fetal observations. The partogram has been developed to aid recognition of failure to labor progress and guide management-specific obstetrical intervention. In the last decade, the use of ultrasound in the delivery room has increased with the advent of more powerful, portable ultrasound machines that have become more readily available for use. Although ultrasound in intrapartum practice is predominantly used for acute management, an ultrasound-based partogram, a sonopartogram, might represent an objective tool for the graphical representation of labor. Demonstrating greater accuracy for fetal head position and more objectivity in the assessment of fetal head station, it could be considered complementary to traditional clinical assessment. The development of the sonopartogram concept would require further undertaking of serial measurements. Advocates of ultrasound will concede that its use has yet to demonstrate a difference in obstetrical and neonatal morbidity in the context of the management of labor and delivery. Taking a step beyond the descriptive graphical representation of labor progress is the question of whether a specific combination of clinical and demographic parameters might be used to inform knowledge of labor outcomes. Intrapartum cesarean deliveries and deliveries assisted by forceps and vacuum are all associated with a heightened risk of maternal and perinatal adverse outcomes. Although these outcomes cannot be precisely predicted, many known risk factors exist. Malposition and high station of the fetal head, short maternal stature, and other factors, such as caput succedaneum, are all implicated in operative delivery; however, the contribution of individual parameters based on clinical and ultrasound assessments has not been quantified. Individualized risk prediction models, including maternal characteristics and ultrasound findings, are increasingly used in women's health-for example, in preeclampsia or trisomy screening. Similarly, intrapartum cesarean delivery models have been developed with good prognostic ability in specifically selected populations. For intrapartum ultrasound to be of prognostic value, robust, externally validated prediction models for labor outcome would inform delivery management and allow shared decision-making with parents.
Collapse
|
8
|
Cuerva MJ, Rodriguez E, Perez De Aguado M, Gil MDM, Rolle V, Lopez F, Bartha JL. Intrapartum ultrasound in maternal lateral versus semi-recumbent posture. A repeated measures study. Eur J Obstet Gynecol Reprod Biol 2023; 285:46-49. [PMID: 37044018 DOI: 10.1016/j.ejogrb.2023.03.035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2023] [Revised: 03/05/2023] [Accepted: 03/28/2023] [Indexed: 03/31/2023]
Abstract
OBJECTIVE This study aimed to assess whether intrapartum ultrasound (ITU) measurements in maternal lateral posture are superimposable to ITU measurements in semi-recumbent position. STUDY DESIGN A single-center, repeated measures design was used. Women in the second stage of labor were randomized to ITU first in semi-recumbent followed by ITU in side-lying posture without and with contraction, or inversely. The angle of progression (AOP) and the head-perineum distance (HPD) between contractions (AOP1 and HPD1) and with contraction (AOP2 and HPD2) were measured in each maternal posture. The differences between AOP1 and AOP2 (dAOP), and between HPD1 and HPD2 (dHPD) were calculated. RESULTS AND CONCLUSIONS Forty-two women participated in the study. A generalized estimating equation model showed that AOP1 (-3.00°; 95 % CI -5.77 to -0.23; p = 0.03) and AOP2 (-4.14°; 95 % CI -7.20 to -1.08; p = 0.008) were lower in semi-recumbent compared to maternal lateral posture. HPD1 (+1.43 mm; 95 % CI 0.05-2.81; p = 0.042) and HPD2 (+1.53 mm; 95 % CI 0.17-2.89; p = 0.03) were higher in semi-recumbent position. Differences in the ITU measurements in maternal lateral posture compared to semi-recumbent position are small. Monitoring the second stage of labor with ITU in lateral maternal posture is possible.
Collapse
Affiliation(s)
- Marcos Javier Cuerva
- Hospital Universitario La Paz, Department of Obstetrics, Madrid, Spain; School of medicine. Universidad Autónoma de Madrid, Spain.
| | - Elena Rodriguez
- Hospital Universitario La Paz, Department of Obstetrics, Madrid, Spain
| | | | - Maria Del Mar Gil
- Hospital Universitario de Torrejón, Department of Obstetrics and Gynecology, Spain; School of Health Sciences, Universidad Francisco de Vitoria, Madrid, Spain
| | - Valeria Rolle
- Instituto de Investigación Sanitaria del Principado de Asturias (ISPA), Spain
| | - Francisco Lopez
- Hospital Universitario La Paz, Department of Obstetrics, Madrid, Spain
| | - José Luis Bartha
- Hospital Universitario La Paz, Department of Obstetrics, Madrid, Spain; School of medicine. Universidad Autónoma de Madrid, Spain
| |
Collapse
|
9
|
Intrapartum ultrasound use in clinical practice as a predictor of delivery mode during prolonged second stage of labor. Arch Gynecol Obstet 2023; 307:763-770. [PMID: 35576076 DOI: 10.1007/s00404-022-06469-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Accepted: 02/15/2022] [Indexed: 11/02/2022]
Abstract
PURPOSE To determine the validity of intrapartum ultrasound (IPUS), and particularly the angle of progression (AOP), in predicting delivery mode when measured in real-life clinical practice among women with protracted second stages of labor. METHODS Using electronic medical records, nulliparous women with a second stage of labor of ≥ 3 h ("prolonged") and a documented AOP measurement during the second stage were identified. The ability of a single AOP measurement in "prolonged" second stage to predict a vaginal delivery (VD) was assessed. Fetal head descent, measured by AOP change/h (calculated from serial measurements), was compared between women who delivered vaginally and those who had a cesarean delivery (CD) for arrest of descent. RESULTS Of the 191 women who met the inclusion criteria, 62 (32.5%) delivered spontaneously, 96 (50.2%) had a vacuum extraction (VE) and 33 (17.3%) had a CD. The mean AOP was wider among women who had VD (spontaneous or VE) compared to those who had CD (153° ± 19 vs. 133° ± 17, p < 0.001). Wider AOPs were associated with higher rates of VD and an AOP ≥ 127° was associated with a VD rate of 88.6% (148/167). Among the 87 women who had more than one AOP measurement, the mean AOP change per hour was higher in the VD group than in the CD group (15.1° ± 11.4° vs. 6.2° ± 6.3°, p < 0.001). CONCLUSION Ultrasound-assessed fetal head station in nulliparous women with a protracted second stage of labor can be an accurate and objective additive tool in predicting the mode and interval time to delivery in real-life clinical practice.
Collapse
|
10
|
Nallet C, Ramirez Zegarra R, Mazellier S, Dall'asta A, Puyraveau M, Lallemant M, Ramanah R, Riethmuller D, Ghi T, Mottet N. Head-to-perineum distance measured transperineally as a predictor of failed midcavity vacuum-assisted delivery. Am J Obstet Gynecol MFM 2023; 5:100827. [PMID: 36464238 DOI: 10.1016/j.ajogmf.2022.100827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Accepted: 11/28/2022] [Indexed: 12/02/2022]
Abstract
BACKGROUND During the second stage of labor, in case of a need for a fetal extraction at midcavity, the choice of attempting the procedure between operative vaginal delivery and cesarean delivery is difficult. Moreover, guidelines on this subject are not clear. OBJECTIVE This study aimed to identify antenatal and intrapartum parameters associated with a failed midcavity vacuum-assisted delivery and its association with maternal and neonatal adverse outcomes. STUDY DESIGN This was a single-center, retrospective, cohort study conducted at a tertiary maternity hospital in France from January 2010 to December 2020. Women with singleton pregnancies under epidural analgesia with nonanomalous cephalic presenting fetuses and gestational ages at ≥37 weeks of gestation, who were submitted to midcavity vacuum-assisted delivery, were included. Following the American College of Obstetricians and Gynecologists definition, midcavity was defined as the presenting part of the fetus (ie, the fetal head) found at stations 0 and +1. For research purposes, all patients were submitted to transperineal ultrasound to evaluate the head-to-perineum distance, however, this measurement did not affect the decision to perform a midcavity vacuum-assisted delivery. The primary outcome of the study was failed midcavity vacuum-assisted delivery leading to cesarean delivery or the use of a different instrument to achieve vaginal delivery. RESULTS Overall, 951 cases of midcavity vacuum-assisted delivery were included in this study. Failed midcavity vacuum-assisted delivery occurred in 242 patients (25.4%). Factors independently associated with failed midcavity vacuum-assisted delivery included maternal height (adjusted odds ratio, 0.96; 95% confidence interval, 0.94-0.99; P=.002), duration of the active phase of the first stage of labor (adjusted odds ratio, 1.11; 95% confidence interval, 1.05-1.17; P<.001), nonocciput anterior fetal head position (adjusted odds ratio, 1.47; 95% confidence interval, 1.06-2.04; P=.02), z score of the head-to-perineum distance (adjusted odds ratio, 1.23; 95% confidence interval, 1.05-1.43; P=.01), and birthweight of >4000 g (adjusted odds ratio, 2.04; 95% confidence interval, 1.28-3.26; P=.003). Women submitted to a failed midcavity vacuum-assisted delivery were more likely to have a major postpartum hemorrhage (7.1% vs 2.0%; P<.001), whereas neonates were more likely to have an umbilical artery pH of <7.1 (30.5% vs 19.8%; P=.001), be admitted to the neonatal intensive care unit (9.6% vs 4.7%; P=.005), and have a severe caput succedaneum (14.9% vs 0.7%; P<.001). Subgroup analysis on all patients with a fetal head station of 0 found that the head-to-perineum distance was the only independent variable associated with failed midcavity vacuum-assisted delivery (adjusted odds ratio, 1.66; 95% confidence interval, 1.29-2.12; P<.001). The area under the receiving operating characteristic curve of the head-to-perineum distance in this subgroup population was 0.67 (95% confidence interval, 0.60-0.73; P<.001), and the optimal cutoff point of the head-to-perineum distance measurement discriminating between failed and successful midcavity vacuum-assisted deliveries was 55 mm. It was associated with a 0.90 (95% confidence interval, 0.83-0.95) sensitivity, 0.19 (95% confidence interval, 0.14-0.25) specificity, 0.36 (95% confidence interval, 0.30-0.42) positive predictive value, and 0.80 (95% confidence interval, 0.66-0.90) negative predictive value. CONCLUSION Study data showed that a high fetal head station, measured using the head-to-perineum distance, and a nonocciput anterior position of the fetal head are independently associated with failed midcavity vacuum-assisted delivery. The result supported the systematic assessment of the sonographic head station and position before performing a midcavity vacuum-assisted delivery.
Collapse
Affiliation(s)
- Camille Nallet
- Department of Obstetrics and Gynaecology, University Hospital of Besançon, University of Franche-Comté, Besançon, France (Drs Nallet, Mazellier, Lallemant, Ramanah, Riethmuller, and Mottet)
| | - Ruben Ramirez Zegarra
- Department of Obstetrics and Gynaecology, University Hospital of Parma, University of Parma, Parma, Italy (Drs Ramirez Zegarra, Dall'asta, and Ghi)
| | - Sylvia Mazellier
- Department of Obstetrics and Gynaecology, University Hospital of Besançon, University of Franche-Comté, Besançon, France (Drs Nallet, Mazellier, Lallemant, Ramanah, Riethmuller, and Mottet)
| | - Andrea Dall'asta
- Department of Obstetrics and Gynaecology, University Hospital of Parma, University of Parma, Parma, Italy (Drs Ramirez Zegarra, Dall'asta, and Ghi)
| | - Marc Puyraveau
- Clinical Methodology Center, University Hospital of Besançon, University of Franche-Comté, Besançon, France (Mr Puyraveau)
| | - Marine Lallemant
- Department of Obstetrics and Gynaecology, University Hospital of Besançon, University of Franche-Comté, Besançon, France (Drs Nallet, Mazellier, Lallemant, Ramanah, Riethmuller, and Mottet)
| | - Rajeev Ramanah
- Department of Obstetrics and Gynaecology, University Hospital of Besançon, University of Franche-Comté, Besançon, France (Drs Nallet, Mazellier, Lallemant, Ramanah, Riethmuller, and Mottet); Nanomedecine Laboratory, Imaging, and Therapeutics, INSERM EA 4662, University of Franche-Comté, Besançon, France (Drs Ramanah, and Mottet)
| | - Didier Riethmuller
- Department of Obstetrics and Gynaecology, University Hospital of Besançon, University of Franche-Comté, Besançon, France (Drs Nallet, Mazellier, Lallemant, Ramanah, Riethmuller, and Mottet); Department of Obstetrics and Gynaecology, University Hospital of Grenoble, University of Grenoble Alpes, Grenoble, France. (Dr Riethmuller)
| | - Tullio Ghi
- Department of Obstetrics and Gynaecology, University Hospital of Parma, University of Parma, Parma, Italy (Drs Ramirez Zegarra, Dall'asta, and Ghi).
| | - Nicolas Mottet
- Department of Obstetrics and Gynaecology, University Hospital of Besançon, University of Franche-Comté, Besançon, France (Drs Nallet, Mazellier, Lallemant, Ramanah, Riethmuller, and Mottet); Nanomedecine Laboratory, Imaging, and Therapeutics, INSERM EA 4662, University of Franche-Comté, Besançon, France (Drs Ramanah, and Mottet)
| |
Collapse
|
11
|
Assessment of labor progress by ultrasound vs manual examination: a randomized controlled trial. Am J Obstet Gynecol MFM 2023; 5:100817. [PMID: 36400420 DOI: 10.1016/j.ajogmf.2022.100817] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 11/10/2022] [Accepted: 11/10/2022] [Indexed: 11/17/2022]
Abstract
BACKGROUND Assessment of labor progress via digital examination is considered the standard of care in most delivery rooms. However, this method can be stressful, painful, and imprecise, and multiple examinations increase the risk for chorioamnionitis. Intrapartum ultrasound was found to be an objective, noninvasive tool to monitor labor progression. OBJECTIVE This study aimed to investigate whether, among nulliparous women, the use of intrapartum ultrasound can reduce the rate of intrapartum fever by reducing the number of digital examinations. STUDY DESIGN This was a prospective, randomized controlled trial in term nulliparas admitted with prelabor rupture of membranes, induction of labor, or in latent phase of labor with a cervical dilation of <4 cm. Women were randomized into 1 of the following 2 arms: (1) labor progress assessed by ultrasound, avoiding digital examinations as much as possible; and (2) control group in which labor progression was assessed according to the regular protocol. Before the study, all labor ward physicians underwent training in intrapartum ultrasound. RESULTS A total of 90 women were randomized to the ultrasound group and 92 were randomized to the control group. When compared with the control group, the ultrasound group had significantly lower rates of intrapartum fever (11.1% vs 26.1%; P=.01), clinical chorioamnionitis (3.3% vs 16.5%; P>.01), and histologic chorioamnionitis (2.2% vs 9.8%; P=.03). The median number of digital examinations was significantly lower in the ultrasound group (5; interquartile range, 4-6) than in the control group (8; interquartile range, 6-10; P<.01). The median number of digital examinations per hour in the ultrasound group was significantly lower than in the control group (0.2 vs 0.4; P<.01). The induction rates, time from admission to delivery, mode of delivery, Apgar score at 5 minutes, and neonatal intensive care unit admission rates did not differ significantly between the groups. CONCLUSION The use of intrapartum ultrasound lessens the total number of digital examinations needed to be performed during labor and, consequently, the incidence of intrapartum fever and chorioamnionitis are reduced. No adverse effects on labor progression and short-term maternal or neonatal outcomes were noted.
Collapse
|
12
|
Yano E, Iriyama T, Hanaoka S, Sayama S, Ichinose M, Toshimitsu M, Seyama T, Sone K, Kumasawa K, Nagamatsu T, Kobayashi K, Fujii T, Osuga Y. Anatomical identification of ischial spines applicable to intrapartum transperineal ultrasound based on magnetic resonance imaging of pregnant women. J Matern Fetal Neonatal Med 2022; 35:9736-9741. [PMID: 35287536 DOI: 10.1080/14767058.2022.2051007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
OBJECTIVE Intrapartum transperineal ultrasound is considered useful in judging fetal head descent; however, the inability to detect ischial spines on ultrasound images has been a drawback to its legitimacy. The current study aimed to determine the anatomical location of ischial spines, which can be directly applied to intrapartum transperineal ultrasound images. METHOD Based on magnetic resonance imaging (MRI) of 67 pregnant women at 33+2 [31+6-34+0] weeks gestation (median [interquartile range: IQR]), we calculated the angle between the pubic symphysis and the midpoint of ischial spines (midline symphysis-ischial spine angle; mSIA), which is theoretically equivalent to the angle of progression at fetal head station 0 on ITU, by determining spatial coordinates of pelvic landmarks and utilizing spatial vector analysis. Furthermore, we measured symphysis-ischial spine distance (SID), defined as the distance between the vertical plane passing the lower edge of the pubic symphysis and the plane that passes the ischial spines. RESULTS As a result, mSIA was 109.6° [105.1-114.0] and SID 26.4 mm [19.8-30.7] (median, [IQR]). There was no correlation between mSIA or SID and maternal characteristics, including physique. CONCLUSIONS We established a novel method to measure the components of the pelvic anatomy by analyzing the three-dimensional coordinates of MRI data and identified the anatomical location of ischial spines which can be applied to ultrasound images. Our results provide valuable evidence to enhance the reliability of intrapartum transperineal ultrasound in assessing fetal head descent by considering the location of ischial spines.
Collapse
Affiliation(s)
- Eriko Yano
- Department of Obstetrics and Gynecology, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Takayuki Iriyama
- Department of Obstetrics and Gynecology, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Shouhei Hanaoka
- Department of Radiology, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Seisuke Sayama
- Department of Obstetrics and Gynecology, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Mari Ichinose
- Department of Obstetrics and Gynecology, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Masatake Toshimitsu
- Department of Obstetrics and Gynecology, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Takahiro Seyama
- Department of Obstetrics and Gynecology, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Kenbun Sone
- Department of Obstetrics and Gynecology, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Keiichi Kumasawa
- Department of Obstetrics and Gynecology, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Takeshi Nagamatsu
- Department of Obstetrics and Gynecology, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Koichi Kobayashi
- Department of Obstetrics and Gynecology, Tokyo Yamate Medical Center, Tokyo, Japan
| | - Tomoyuki Fujii
- Department of Obstetrics and Gynecology, Sanno Hospital, Tokyo, Japan
| | - Yutaka Osuga
- Department of Obstetrics and Gynecology, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| |
Collapse
|
13
|
Rizzo G, Ghi T, Henrich W, Tutschek B, Kamel R, Lees CC, Mappa I, Kovalenko M, Lau W, Eggebo T, Achiron R, Sen C. Ultrasound in labor: clinical practice guideline and recommendation by the WAPM-World Association of Perinatal Medicine and the PMF-Perinatal Medicine Foundation. J Perinat Med 2022; 50:1007-1029. [PMID: 35618672 DOI: 10.1515/jpm-2022-0160] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Accepted: 03/28/2022] [Indexed: 12/27/2022]
Abstract
This recommendation document follows the mission of the World Association of Perinatal Medicine in collaboration with the Perinatal Medicine Foundation. We aim to bring together groups and individuals throughout the world for standardization to implement the ultrasound evaluation in labor ward and improve the clinical management of labor. Ultrasound in labor can be performed using a transabdominal or a transperineal approach depending upon which parameters are being assessed. During transabdominal imaging, fetal anatomy, presentation, liquor volume, and placental localization can be determined. The transperineal images depict images of the fetal head in which calculations to determine a proposed fetal head station can be made.
Collapse
Affiliation(s)
- Giuseppe Rizzo
- Department of Obstetrics and Gynecology, Università di Roma Tor Vergata, Fondazione Policlinico Tor Vergata, Rome, Italy
| | - Tullio Ghi
- Department of Medicine and Surgery, University of Parma, Parma, Italy
- UOC Ostetricia e Ginecologia Azienda Ospedaliera Universitaria di Parma, Parma, Italy
- Della Scuola di Specializzazione in Ostetricia e Ginecologia Presidente del CdS Ostetricia, Parma, Italy
| | - Wolfgang Henrich
- Department of Obstetrics, University Medical Center Berlin, Charité, Berlin, Germany
| | - Boris Tutschek
- Specialist in Gynecology and Obstetrics FMH, Focus Obstetrics and Feto-Maternal Medicine, Zurich, Switzerland
| | - Rasha Kamel
- Department of Obstetrics and Gynecology Maternal-Fetal medicine unit, Cairo University, Cairo, Egypt
| | - Christoph C Lees
- Imperial College London and Head of Fetal Medicine, Imperial College Healthcare NHS Trust, London, UK
- Department of Development & Regeneration, KU Leuven, Leuven, Belgium
| | - Ilenia Mappa
- Università di Roma Tor Vergata, Unità Operativa di Medicina Materno Fetale Ospedale Cristo Re Roma, Rome, Italy
| | | | - Wailam Lau
- Department of O&G, Kwong Wah Hospital, Hong Kong SAR, China
| | - Torbjorn Eggebo
- National center for fetal medicine, St.Olavs Hospital, Trondheim, Norway
| | - Reuven Achiron
- Department of Obstetrics and Gynecology, Ultrasound unit, Tel-Hashomer, Sackler School of Medicine, Tel-Aviv University, Ramat-Gan, Israel
| | - Cihat Sen
- Perinatal Medicine Foundation, Istanbul, Turkey
- Department of Perinatal Medicine, Memorial BAH Hospital, Istanbul, Turkey
- Department of Perinatal Medicine, Obstetrics and Gynecology, Istanbul University-Cerrahpasa, Istanbul, Turkey
| |
Collapse
|
14
|
Multitask Deep Neural Network for the Fully Automatic Measurement of the Angle of Progression. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2022; 2022:5192338. [PMID: 36092792 PMCID: PMC9462992 DOI: 10.1155/2022/5192338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Accepted: 08/04/2022] [Indexed: 11/22/2022]
Abstract
The angle of progression (AoP) for assessing fetal head (FH) descent during labor is measured from the standard plane of transperineal ultrasound images as the angle between a line through the long axis of pubic symphysis (PS) and a second line from the right end of PS tangentially to the contour of the FH. This paper presents a multitask network with a shared feature encoder and three task-special decoders for standard plane recognition (Task1), image segmentation (Task2) of PS and FH, and endpoint detection (Task3) of PS. Based on the segmented FH and two endpoints of PS from standard plane images, we determined the right FH tangent point that passes through the right endpoint of PS and then computed the AoP using the above three points. In this paper, the efficient channel attention unit is introduced into the shared feature encoder for improving the robustness of layer region encoding, while an attention fusion module is used to promote cross-branch interaction between the encoder for Task2 and that for Task3, and a shape-constrained loss function is designed for enhancing the robustness to noise based on the convex shape-prior. We use Pearson's correlation coefficient and the Bland–Altman graph to assess the degree of agreement. The dataset includes 1964 images, where 919 images are nonstandard planes, and the other 1045 images are standard planes including PS and FH. We achieve a classification accuracy of 92.26%, and for the AoP calculation, an absolute mean (STD) value of the difference in AoP (∆AoP) is 3.898° (3.192°), the Pearson's correlation coefficient between manual and automated AoP was 0.964 and the Bland-Altman plot demonstrates they were statistically significant (P < 0.05). In conclusion, our approach can achieve a fully automatic measurement of AoP with good efficiency and may help labor progress in the future.
Collapse
|
15
|
Nassr AA, Hessami K, Berghella V, Bibbo C, Shamshirsaz AA, Shirdel Abdolmaleki A, Marsoosi V, Clark SL, Belfort MA, Shamshirsaz AA. Angle of progression measured using transperineal ultrasound for prediction of uncomplicated operative vaginal delivery: systematic review and meta-analysis. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2022; 60:338-345. [PMID: 35238424 DOI: 10.1002/uog.24886] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/26/2021] [Revised: 02/17/2022] [Accepted: 02/21/2022] [Indexed: 06/14/2023]
Abstract
OBJECTIVE To determine whether intrapartum transperineal ultrasound measurement of the angle of progression (AoP) during the second stage of labor can predict uncomplicated operative vaginal delivery (OVD) using vacuum or forceps extraction. METHODS A systematic search in PubMed, EMBASE, Scopus, Web of Science and Google Scholar was performed from inception to February 2021. Studies assessing the predictive accuracy of AoP, measured using intrapartum transperineal ultrasound, for uncomplicated OVD, defined as successful vaginal delivery within three pulls using forceps or no more than two detachments of the vacuum extractor cup, were included. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Summary receiver-operating-characteristics (ROC) curves, pooled sensitivity and specificity, area under the ROC curve (AUC) and summary likelihood ratios (LRs) were calculated. RESULTS Seven studies reporting on a total of 782 patients undergoing OVD were included in this systematic review and meta-analysis. Second-stage AoP measured during maternal rest had a pooled sensitivity of 80% (95% CI, 59-92%) and specificity of 89% (95% CI, 76-95%), with a LR+ of 7.3 (95% CI, 3.1-15.8) for uncomplicated OVD. AoP measured during active pushing had a sensitivity of 91% (95% CI, 85-94%) and specificity of 83% (95% CI, 69-92%), with a LR+ of 5.4 (95% CI, 2.7-10.6) for uncomplicated OVD. The performance of AoP measured at rest was particularly high in nulliparous women, with a sensitivity of 87% (95% CI, 75-94%) and specificity of 90% (95% CI, 82-94%) for uncomplicated OVD. CONCLUSION AoP may be a reliable predictor for uncomplicated OVD when measured during the second stage of labor, especially in nulliparous women. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
Affiliation(s)
- A A Nassr
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Houston, TX, USA
- Department of Obstetrics and Gynecology, Women's Health Hospital, Assiut University, Assiut, Egypt
| | - K Hessami
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Houston, TX, USA
- Maternal-Fetal Medicine Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| | - V Berghella
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, USA
| | - C Bibbo
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Brigham and Women's, Boston, MA, USA
| | - A A Shamshirsaz
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Houston, TX, USA
| | - A Shirdel Abdolmaleki
- Maternal-Fetal Medicine Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| | - V Marsoosi
- Department of Obstetrics and Gynecology, Tehran University of Medical Sciences, Tehran, Iran
| | - S L Clark
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Houston, TX, USA
| | - M A Belfort
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Houston, TX, USA
| | - A A Shamshirsaz
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Houston, TX, USA
| |
Collapse
|
16
|
Accuracy of non-invasive methods for assessing the progress of labor in the first stage: a systematic review and meta-analysis. BMC Pregnancy Childbirth 2022; 22:608. [PMID: 35915400 PMCID: PMC9341104 DOI: 10.1186/s12884-022-04938-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Accepted: 07/12/2022] [Indexed: 11/19/2022] Open
Abstract
Background The World Health Organization in recent years has emphasized reducing the possibility of unnecessary interventions in natural childbirth, but little is known about the accuracy of non-invasive methods when assessing the progress of labor. This paper presents a literature review to assess strategies that support non-invasive methods for labor during the first stage. It evaluates the available evidence to provide the most suitable assessments and predictions that objectively identify the progress of low-risk labor during the first stage of labor. Methods A search for relevant literature was conducted using the electronic databases of PubMed, CINAHL, Web of Sciences, the Cochrane Library, Scopus, Medline (OVID), and CEPS, with publications up to November 2021. Records were screened against pre-specified inclusion/exclusion criteria and the potential papers from Google Scholar were examined to identify additional papers that may have been missed. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was used to appraise the methodological quality of the included studies. The certainty of the evidence was assessed using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach. Two independent investigators extracted the review’s characteristics, and discrepancies were resolved by consensus. This review calculated individual and pooled sensitivity, specificity, and positive predictive values, which were exported to STATA (version 14; Stata Corp., College Station, TX) to represent the performance of diagnostic testing. Results Our search returned 2283 reports of which 13 fulfilled the inclusion criteria, accounting for 2594 women. The subjects were divided into groups according to the diagnostic tests used to assess the progress of their labor, including appearance assessment and sonographic imaging parameters (head perineum distance, HPD; angle of progression, AOP, and other parameters). HPD pooled sensitivity was 0.74 (0.65–0.82), and specificity was 0.77 (0.69–0.84). The pooled diagnostic odds ratio (DOR) was 8.21 (4.67–14.41) and 10.34 (5.02–21.27), respectively. The results of subgroup analysis showed that the summary sensitivity and specificity were of medium accuracy overall. The quality of evidence as assessed with GRADE was low. Conclusion Vaginal examination is an intrinsic element in the use of the partogram, while transperineal ultrasound can also be used as an auxiliary tool. However, the presence of publication bias within the parameters of ultrasound indicates that the diagnostic performance may be overestimated. Thus, randomized controlled trials or large-scale prospective cohort studies are necessary. Supplementary Information The online version contains supplementary material available at 10.1186/s12884-022-04938-y.
Collapse
|
17
|
Sánchez García D, Aguado del Hoyo A, Sánchez Pérez M, Larroca SGT, Ruiz Martín Y, Gordillo Gutiérrez I, Arribas CB, Alvarez-Mon M, Ortega MA, De Leon-Luis J. Effects of Sex, Age and Height on Symphysis–Ischial Spine Distance Measured on a Pelvic CT. J Clin Med 2022; 11:jcm11092395. [PMID: 35566521 PMCID: PMC9104774 DOI: 10.3390/jcm11092395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Revised: 04/21/2022] [Accepted: 04/22/2022] [Indexed: 02/01/2023] Open
Abstract
Objective: To examine the influence of age, sex and height on the symphysis–ischial spine distance (SID) measured on pelvic Computed tomography (CT)images in subjects of reproductive age, and to determine the interobserver reproducibility. This measurement (SID) is of great importance because the use of intrapartum ultrasound is based on the assumption of a specific value (30 mm) of such a measurement. Methods: This was a cross-sectional descriptive study in which SID was measured in subjects aged 20 to 44 years who had been scheduled for pelvic CT at our centre from January 2018 to May 2021 for different reasons. Radiographic measurements of the pelvis were obtained through the multiplanar reconstruction of the CT image. The images obtained from all of the participants were independently assessed by three senior radiologists, and the SID measurements made by each one were blinded from those of the remaining observers. Correlations between the SID and patient age, height and sex were analyzed by univariate and multivariate linear regression. Results: The mean SID for 87 of the enrolled participants (45 women, 42 men) was 28.2 ± 6.25 mm. Among the observers, the mean difference in this distance was 1 to 2 mm, and was scarcely related to measurement size, with agreement being greater than 70%. The mean SID was significantly related to sex and height (SID = −24.9 − 6.51 × sex (0 or 1) + 0.34 × height (cm); p = 0.01; sex equals 1 for a man and 0 for a woman), such that it was a mean of 2.5 mm greater in women than men (29.50 mm vs. 26.99 mm). Conclusion: Measurements of SID on CT images show good interobserver reproducibility, and are related to sex and height.
Collapse
Affiliation(s)
- Daniel Sánchez García
- Department of Radiology, University Hospital Gregorio Marañón, 28009 Madrid, Spain; (D.S.G.); (A.A.d.H.); (M.S.P.); (Y.R.M.); (I.G.G.)
- Group of Pathophysiology in Women, Pregnancy, Labor, and Puerperium, Health Research Institute Gregorio Marañón, 28040 Madrid, Spain; (S.G.-T.L.); (J.D.L.-L.)
- Maternal and Infant Research Investigation Unit, Alonso Family Foundation (UDIMIFFA), 28009 Madrid, Spain
| | - Alejandra Aguado del Hoyo
- Department of Radiology, University Hospital Gregorio Marañón, 28009 Madrid, Spain; (D.S.G.); (A.A.d.H.); (M.S.P.); (Y.R.M.); (I.G.G.)
- Group of Pathophysiology in Women, Pregnancy, Labor, and Puerperium, Health Research Institute Gregorio Marañón, 28040 Madrid, Spain; (S.G.-T.L.); (J.D.L.-L.)
- Maternal and Infant Research Investigation Unit, Alonso Family Foundation (UDIMIFFA), 28009 Madrid, Spain
| | - María Sánchez Pérez
- Department of Radiology, University Hospital Gregorio Marañón, 28009 Madrid, Spain; (D.S.G.); (A.A.d.H.); (M.S.P.); (Y.R.M.); (I.G.G.)
- Group of Pathophysiology in Women, Pregnancy, Labor, and Puerperium, Health Research Institute Gregorio Marañón, 28040 Madrid, Spain; (S.G.-T.L.); (J.D.L.-L.)
- Maternal and Infant Research Investigation Unit, Alonso Family Foundation (UDIMIFFA), 28009 Madrid, Spain
| | - Santiago García-Tizón Larroca
- Group of Pathophysiology in Women, Pregnancy, Labor, and Puerperium, Health Research Institute Gregorio Marañón, 28040 Madrid, Spain; (S.G.-T.L.); (J.D.L.-L.)
- Maternal and Infant Research Investigation Unit, Alonso Family Foundation (UDIMIFFA), 28009 Madrid, Spain
- Department of Public and Maternal and Child Health, School of Medicine, Complutense University of Madrid, 28040 Madrid, Spain
- Department of Obstetrics and Gynecology, University Hospital Gregorio Marañón, 28009 Madrid, Spain
| | - Yolanda Ruiz Martín
- Department of Radiology, University Hospital Gregorio Marañón, 28009 Madrid, Spain; (D.S.G.); (A.A.d.H.); (M.S.P.); (Y.R.M.); (I.G.G.)
- Group of Pathophysiology in Women, Pregnancy, Labor, and Puerperium, Health Research Institute Gregorio Marañón, 28040 Madrid, Spain; (S.G.-T.L.); (J.D.L.-L.)
- Maternal and Infant Research Investigation Unit, Alonso Family Foundation (UDIMIFFA), 28009 Madrid, Spain
| | - Isabel Gordillo Gutiérrez
- Department of Radiology, University Hospital Gregorio Marañón, 28009 Madrid, Spain; (D.S.G.); (A.A.d.H.); (M.S.P.); (Y.R.M.); (I.G.G.)
- Group of Pathophysiology in Women, Pregnancy, Labor, and Puerperium, Health Research Institute Gregorio Marañón, 28040 Madrid, Spain; (S.G.-T.L.); (J.D.L.-L.)
- Maternal and Infant Research Investigation Unit, Alonso Family Foundation (UDIMIFFA), 28009 Madrid, Spain
| | - Coral Bravo Arribas
- Group of Pathophysiology in Women, Pregnancy, Labor, and Puerperium, Health Research Institute Gregorio Marañón, 28040 Madrid, Spain; (S.G.-T.L.); (J.D.L.-L.)
- Maternal and Infant Research Investigation Unit, Alonso Family Foundation (UDIMIFFA), 28009 Madrid, Spain
- Department of Public and Maternal and Child Health, School of Medicine, Complutense University of Madrid, 28040 Madrid, Spain
- Department of Obstetrics and Gynecology, University Hospital Gregorio Marañón, 28009 Madrid, Spain
- Correspondence:
| | - Melchor Alvarez-Mon
- Department of Medicine and Medical Specialities, Faculty of Medicine and Health Sciences, University of Alcalá, 28801 Alcala de Henares, Spain; (M.A.-M.); (M.A.O.)
- Ramón y Cajal Institute of Sanitary Research (IRYCIS), 28034 Madrid, Spain
- Immune System Diseases-Rheumatology, Oncology Service an Internal Medicine (CIBEREHD), University Hospital Príncipe de Asturias, 28806 Alcala de Henares, Spain
| | - Miguel A. Ortega
- Department of Medicine and Medical Specialities, Faculty of Medicine and Health Sciences, University of Alcalá, 28801 Alcala de Henares, Spain; (M.A.-M.); (M.A.O.)
- Ramón y Cajal Institute of Sanitary Research (IRYCIS), 28034 Madrid, Spain
| | - Juan De Leon-Luis
- Group of Pathophysiology in Women, Pregnancy, Labor, and Puerperium, Health Research Institute Gregorio Marañón, 28040 Madrid, Spain; (S.G.-T.L.); (J.D.L.-L.)
- Maternal and Infant Research Investigation Unit, Alonso Family Foundation (UDIMIFFA), 28009 Madrid, Spain
- Department of Public and Maternal and Child Health, School of Medicine, Complutense University of Madrid, 28040 Madrid, Spain
- Department of Obstetrics and Gynecology, University Hospital Gregorio Marañón, 28009 Madrid, Spain
| |
Collapse
|
18
|
Haumonte JB, Blanc J, Castel P, Mace P, Auquier P, d’Ercole C, Bretelle F. Uncertain fetal head engagement: a prospective randomized controlled trial comparing digital exam with angle of progression. Am J Obstet Gynecol 2022; 227:625.e1-625.e8. [PMID: 35452654 DOI: 10.1016/j.ajog.2022.04.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2022] [Revised: 03/26/2022] [Accepted: 04/13/2022] [Indexed: 11/01/2022]
Abstract
BACKGROUND Uncertain fetal head engagement represents 4% of obstetrical situations associated with an increased risk of postpartum hemorrhage, notably in cases of cesarean delivery and increased neonatal impairment owing to failed vaginal instrumental delivery. In this obstetrical condition, cesarean delivery is recommended, but vaginal delivery is possible in two-thirds of the cases. During the second stage of labor, the descent of the fetal head can be assessed by sonography, particularly by measuring the angle of progression. OBJECTIVE To evaluate, after a prolonged second stage of labor, the impact of measuring the angle of progression in addition to a digital examination on cesarean delivery rates when fetal head engagement remains uncertain. STUDY DESIGN This open multicenter randomized pragmatic trial included women at term with a singleton cephalic fetus in a clinical occiput anterior position after a prolonged 2-hour second stage of labor with uncertain fetal head engagement. After inclusion in the study, an independent investigator performed ultrasound systematically to confirm the occiput anterior position and measured the angle of progression at the climax of Valsalva pushing. This operator did not participate in labor management. In the study group but not in the control group, the angle of progression was communicated to the obstetrician in charge of labor management. Obstetricians were encouraged to attempt vaginal birth if the angle of progression was >120°. The primary outcome was the cesarean delivery rate. Secondary outcomes were operative delivery rate (cesarean delivery and operative vaginal delivery), maternal complications (third and fourth-degree perineal tears, failed vaginal instrumental delivery, postpartum hemorrhage, hysterectomy), and neonatal outcomes (Apgar score <5 at 10 minutes, umbilical arterial pH <7.10, neonatal wounds, neonatal intensive care unit admission). RESULTS A total of 45 women were included in the study. Occiput anterior position was confirmed in 33 women: 16 in the study group and 17 in the control group. Women's characteristics at baseline were similar between the groups. The median (range) angles of progression were similar: 138.4° (15) and 140.3° (16.9) in the study and control group, respectively. Cesarean delivery rates were 12.5% in the study group and 41.1% in the control group (P=.06). Secondary outcomes were similar between the 2 groups. No failed vaginal instrumental delivery was reported. CONCLUSION Measurement of the angle of progression in addition to digital examination when fetal head engagement remained uncertain showed promising results in decreasing cesarean delivery rates. A larger multicenter randomized controlled trial is needed to confirm these results.
Collapse
|
19
|
Nassr AA, Berghella V, Hessami K, Bibbo C, Bellussi F, Robinson JN, Marsoosi V, Tabrizi R, Safari-Faramani R, Tolcher MC, Shamshirsaz AA, Clark SL, Belfort MA, Shamshirsaz AA. Intrapartum ultrasound measurement of angle of progression at the onset of the second stage of labor for prediction of spontaneous vaginal delivery in term singleton pregnancies: a systematic review and meta-analysis. Am J Obstet Gynecol 2022; 226:205-214.e2. [PMID: 34384775 DOI: 10.1016/j.ajog.2021.07.031] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 07/11/2021] [Accepted: 07/26/2021] [Indexed: 11/17/2022]
Abstract
OBJECTIVE This study aimed to investigate the diagnostic performance of transperineal ultrasound-measured angles of progression at the onset of the second stage of labor for the prediction of spontaneous vaginal delivery in singleton term pregnancies with cephalic presentation. DATA SOURCES We performed a predefined systematic search in PubMed, Embase, Scopus, Web of Science, and Google Scholar from inception to February 5, 2021. STUDY ELIGIBILITY CRITERIA Prospective cohort studies that evaluated the diagnostic performance of transperineal ultrasound-measured angles of progression (index test) at the onset of the second stage of labor (ie, when complete cervical dilation is diagnosed) for the prediction of spontaneous vaginal delivery (reference standard) were eligible for inclusion. Eligible studies were limited to those published as full-text articles in the English language and those that included only parturients with a singleton healthy fetus at term with cephalic presentation. STUDY APPRAISAL AND SYNTHESIS METHODS Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Summary receiver operating characteristic curves, pooled sensitivities and specificities, area under the curve, and summary likelihood ratios were calculated using the Stata software. Subgroup analyses were done based on angle of progression ranges of 108° to 119°, 120° to 140°, and 141° to 153°. RESULTS A total of 8 studies reporting on 887 pregnancies were included. Summary estimates of the sensitivity and specificity of transperineal ultrasound-measured angle of progression at the onset of the second stage of labor for predicting spontaneous vaginal delivery were 94% (95% confidence interval, 88%-97%) and 47% (95% confidence interval, 18%-78%), respectively, for an angle of progression of 108° to 119°, 81% (95% confidence interval, 70%-89%) and 73% (95% confidence interval, 57%-85%), respectively, for an angle of progression of 120° to 140°, and 66% (95% confidence interval, 56%-74%) and 82% (95% confidence interval, 66%-92%), respectively, for an angle of progression of 141° to 153°. Likelihood ratio syntheses gave overall positive likelihood ratios of 1.8 (95% confidence interval, 1-3.3), 3 (95% confidence interval, 2-4.7), and 3.7 (95% confidence interval, 1.7-8.1) and negative likelihood ratios of 0.13 (95% confidence interval, 0.07-0.22), 0.26 (95% confidence interval, 0.18-0.38), and 0.42 (95% confidence interval, 0.29-0.60) for angle of progression ranges of 108° to 119°, 120° to 140°, and 141° to 153°, respectively. CONCLUSION Angle of progression measured by transperineal ultrasound at the onset of the second stage of labor may predict spontaneous vaginal delivery in singleton, term, cephalic presenting pregnancies and has the potential to be used along with physical examinations and other clinical factors in the management of labor and delivery.
Collapse
Affiliation(s)
- Ahmed A Nassr
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Houston, TX
| | - Vincenzo Berghella
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA
| | - Kamran Hessami
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Houston, TX; Maternal-Fetal Medicine Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Carolina Bibbo
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Brigham and Women's Hospital, Boston, MA
| | - Federica Bellussi
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA
| | - Julian N Robinson
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Brigham and Women's Hospital, Boston, MA
| | - Vajiheh Marsoosi
- Department of Obstetrics and Gynecology, Tehran University of Medical Sciences, Tehran, Iran
| | - Reza Tabrizi
- Noncommunicable Diseases Research Center, Fasa University of Medical Sciences, Fasa, Iran; Clinical Research Development Unit, Vali Asr Hospital, Fasa University of Medical Sciences, Fasa, Iran; Health Policy Research Center, Institute of Health, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Roya Safari-Faramani
- Department of Epidemiology, School of Public Health, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | | | - Amir A Shamshirsaz
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Houston, TX
| | - Steven L Clark
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Houston, TX
| | - Michael A Belfort
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Houston, TX
| | | |
Collapse
|
20
|
Plurien A, Berveiller P, Drumez E, Hanssens S, Subtil D, Garabedian C. Ultrasound assessment of fetal head position and station before operative delivery: can it predict difficulty? J Gynecol Obstet Hum Reprod 2022; 51:102336. [DOI: 10.1016/j.jogoh.2022.102336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 01/31/2022] [Accepted: 02/07/2022] [Indexed: 11/29/2022]
|
21
|
Kamel R, Negm S, Badr I, Kahrs BH, Eggebø TM, Iversen JK. Fetal head descent assessed by transabdominal ultrasound: a prospective observational study. Am J Obstet Gynecol 2022; 226:112.e1-112.e10. [PMID: 34389293 DOI: 10.1016/j.ajog.2021.07.030] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Accepted: 07/28/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND Determining fetal head descent, expressed as fetal head station and engagement is an essential part of monitoring progression in labor. Assessing fetal head station is based on the distal part of the fetal skull, whereas assessing engagement is based on the proximal part. Prerequisites for assisted vaginal birth are that the fetal head should be engaged and its lowermost part at or below the level of the ischial spines. The part of the fetal head above the pelvic inlet reflects the true descent of the largest diameter of the skull. In molded (reshaped) fetal heads, the leading bony part of the skull may be below the ischial spines while the largest diameter of the fetal skull still remains above the pelvic inlet. An attempt at assisted vaginal birth in such a situation would be associated with risks. Therefore, the vaginal or transperineal assessments of station should be supplemented with a transabdominal examination. We suggest a method for the assessment of fetal head descent with transabdominal ultrasound. OBJECTIVE To investigate the correlation between transabdominal and transperineal assessment of fetal head descent, and to study fetal head shape at different labor stages and head positions. STUDY DESIGN Women with term singleton cephalic pregnancies admitted to the labor ward for induction of labor or in spontaneous labor, at the Cairo University Hospital and Oslo University Hospital from December 2019 to December 2020 were included. Fetal head descent was assessed with transabdominal ultrasound as the suprapubic descent angle between a longitudinal line through the symphysis pubis and a line from the upper part of the symphysis pubis extending tangentially to the fetal skull. We compared measurements with transperineally assessed angle of progression and investigated interobserver agreement. We also measured the part of fetal head above and below the symphysis pubis at different labor stages. RESULTS The study population comprised 123 women, of whom 19 (15%) were examined before induction of labor, 8 (7%) in the latent phase, 52 (42%) in the active first stage and 44 (36%) in the second stage. The suprapubic descent angle and the angle of progression could be measured in all cases. The correlation between the transabdominal and transperineal measurements was -0.90 (95% confidence interval, -0.86 to -0.93). Interobserver agreement was examined in 30 women and the intraclass correlation coefficient was 0.98 (95% confidence interval, 0.95-0.99). The limits of agreement were from -9.5 to 7.8 degrees. The fetal head was more elongated in occiput posterior position than in non-occiput posterior positions in the second stage of labor. CONCLUSION We present a novel method of examining fetal head descent by assessing the proximal part of the fetal skull with transabdominal ultrasound. The correlation with transperineal ultrasound measurements was strong, especially early in labor. The fetal head was elongated in the occiput posterior position during the second stage of labor.
Collapse
|
22
|
Abdelsameea Ibrahim G, Soliman Nasr A, Atta F, Reda M, Abdelghany H, El-Demiry NM, Shalaby M. The Assessment of Intrapartum Transperineal Ultrasonographic Parameters for their Effectiveness in Evaluation of Progress of Labor and Prediction of Mode of Delivery in Egyptian Women. Open Access Maced J Med Sci 2021. [DOI: 10.3889/oamjms.2021.7049] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Introduction: High fetal head station has been associated with prolonged labor and delivery outcomes. Although clinical assessment of fetal head station is both subjective and unreliable, women with prolonged labor are subjected to multiple digital vaginal examinations. The use of ultrasound has been proposed to aid in the management of labor since 1990s. Ultrasound examination is more accurate and reproducible than clinical examination in the diagnosis of fetal head station and in the prediction of arrest of labor. Ultrasound examination can, to some extent, distinguish those women destined for spontaneous vaginal delivery and those destined for operative delivery and may predict the outcome of instrumental vaginal delivery. Such a technique has the potential to reduce the frequency of intrusive internal examinations and associated infection and could be useful in allowing the assessment of women in whom digital VE is traumatic or contra-indicated. Intrapartum ultrasound not only provides objective and quantitative data in labor, but also helps to make more reliable clinical decisions aiming to improve obstetric outcomes of both the mother and fetus as a supplementary tool for active management.
Aim of the work: This study aims at assessing the value of intrapartum transperineal ultrasonography as a quantitative and objective tool in the evaluation of progress of labor and prediction of mode of delivery.
Subjects: This study was a prospective observational study conducted on 600 primiparous women in active first stage of labor admitted to Kasr Al Ainy maternity hospital from January 2017 to June 2018. The studied population was divided into two groups. Group A of 300 women with normal progress of labor and group B of 300 women with prolonged 1st stage of labor.
Methods: Fetal head station(FHS) was assessed clinically by digital vaginal examination (dVE) and sonographically by transperineal ultrasound measurement of head perineal distance (HPD) and angle of progression (AOP). Intrapartum care of the patient continued as normal based only on digital vaginal examinations using the modified WHO partogram. (1). Statistical analysis was targeted towards assessing the potential of the intrapartum ultrasonography in the evaluation of progress of labor and prediction of mode of delivery.
Results: All studied parameters for assessment of FHS (dVE, HPD, and AOP) significantly corelated with each other and with both progress of labor and mode of delivery with P value (<0.001). The highest sensitivity for prediction of progress of labor is observed using dVE (83%), the highest specificity is observed using AOP (78.3%). The highest sensitivity for prediction mode of delivery is for combined HPD & AOP (97.7%) while the highest specificity is for AOP (81%). When combining both HPD and AOP for prediction of mode of delivery, the assessment of both parameters was found to have a high sensitivity of 97.7% and a high positive predictive value of 86.63%.
Conclusion: Intrapartum ultrasound examination is a valuable tool in the prediction of progress of labor and mode of delivery. The assessment of fetal head station by transperineal ultrasound measurement of HPD and AOP is much more informative of the progress of labor and the mode of delivery than digital assessment of fetal head station.
Keywords: Labor, intrapartum ultrasound, Angle of progression, Head perineal distance, fetal head station, digital vaginal examination.
Collapse
|
23
|
Youssef A, Brunelli E, Fiorentini M, Lenzi J, Pilu G, El-Balat A. Breech progression angle: new feasible and reliable transperineal ultrasound parameter for assessment of fetal breech descent in birth canal. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2021; 58:609-615. [PMID: 33847431 DOI: 10.1002/uog.23649] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2021] [Revised: 03/20/2021] [Accepted: 03/26/2021] [Indexed: 06/12/2023]
Abstract
OBJECTIVE To assess the feasibility and reliability of transperineal ultrasound in the assessment of fetal breech descent in the birth canal, by measuring the breech progression angle (BPA). METHODS Women with a singleton pregnancy with the fetus in breech presentation between 34 and 41 weeks' gestation were recruited. Transperineal ultrasound images were acquired in the midsagittal view for each woman, twice by one operator and once by another. Each operator measured the BPA after anonymization of the transperineal ultrasound images. BPA was defined as the angle between a line running along the long axis of the pubic symphysis and another line extending from the most inferior portion of the pubic symphysis tangentially to the lowest recognizable fetal part in the maternal pelvis. Each operator was blinded to all other measurements performed for each woman. Intra- and interobserver reproducibility of BPA measurement was evaluated using the intraclass correlation coefficient (ICC). To investigate the presence of any bias, intra- and interobserver agreement was also analyzed using Bland-Altman analysis. Student's t-test and Levene's W0 test were used to investigate whether a number of different clinical factors had an effect on systematic differences and homogeneity, respectively, between BPA measurements. RESULTS Overall, 44 women were included in the analysis. BPA was measured successfully by both operators on all images. Both intra- and interobserver agreement analyses showed excellent reproducibility in BPA measurement, with ICCs of 0.88 (95% CI, 0.80-0.93) and 0.83 (95% CI, 0.71-0.90), respectively. The mean difference between measurements was 0.4° (95% CI, -1.4 to 2.2°) for intraobserver repeatability and -0.4° (95% CI, -2.6 to 1.8°) for interobserver repeatability. The upper limits of agreement were 12.0° (95% CI, 8.9-15.1°) and 13.6° (95% CI, 9.9-17.3°) for intra- and interobserver repeatability, respectively. The lower limits of agreement were -11.2° (95% CI, -14.3 to -8.1°) and -14.4° (95% CI, -18.2 to -10.7°) for intra- and interobserver repeatability, respectively. No systematic difference between BPA measurements was found on either intra- or interobserver agreement analysis. None of the clinical factors examined (maternal body mass index, maternal age, gestational age at the ultrasound scan and parity) showed a statistically significant effect on intra- or interobserver reliability. CONCLUSIONS BPA represents a new feasible and highly reproducible measurement for the evaluation of fetal breech descent in the birth canal. Future studies assessing its usefulness in the prediction of successful external cephalic version and breech vaginal delivery are needed. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
Affiliation(s)
- A Youssef
- Obstetric Unit, Department of Medical and Surgical Sciences, IRCCS Sant'Orsola-Malpighi University Hospital, University of Bologna, Bologna, Italy
| | - E Brunelli
- Obstetric Unit, Department of Medical and Surgical Sciences, IRCCS Sant'Orsola-Malpighi University Hospital, University of Bologna, Bologna, Italy
| | - M Fiorentini
- Obstetric Unit, Department of Medical and Surgical Sciences, IRCCS Sant'Orsola-Malpighi University Hospital, University of Bologna, Bologna, Italy
| | - J Lenzi
- Section of Hygiene, Public Health and Medical Statistics, Department of Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - G Pilu
- Obstetric Unit, Department of Medical and Surgical Sciences, IRCCS Sant'Orsola-Malpighi University Hospital, University of Bologna, Bologna, Italy
| | - A El-Balat
- Department of Obstetrics and Gynecology, Goethe University Frankfurt, Frankfurt, Germany
| |
Collapse
|
24
|
Dira LM, Tudorache S, Antsaklis P, Daskalakis G, Themistoklis D, Belciug S, Stoean R, Novac M, Cara ML, Dragusin R, Florea M, Patru C, Zorila L, Nagy R, Ruican D, Iliescu DG. Sonographic Evaluation of the Mechanism of Active Labor (SonoLabor Study): observational study protocol regarding the implementation of the sonopartogram. BMJ Open 2021; 11:e047188. [PMID: 34493509 PMCID: PMC8424831 DOI: 10.1136/bmjopen-2020-047188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2020] [Accepted: 06/23/2021] [Indexed: 11/18/2022] Open
Abstract
INTRODUCTION Over the last decades, a large body of literature has shown that intrapartum clinical digital pelvic estimations of fetal head position, station and progression in the pelvic canal are less accurate, compared with ultrasound (US) scan. Given the increasing evidence regarding the advantages of using US to evaluate the mechanism of labour, our study protocol aims to develop sonopartograms for fetal cephalic presentations. They will allow for a more objective evaluation of labour progression than the traditional labour monitoring, which could enable more rapid decisions regarding the mode of delivery. METHODS/ANALYSIS This is a prospective observational study performed in three university hospitals, with an unselected population of women admitted in labour at term. Both clinical and US evaluations will be performed assessing fetal head position, descent and rotation. Specific US parameters regarding fetal head position, progression and rotation will be recorded to develop nomograms in a similar way that partograms were developed. The primary outcome is to develop nomograms for the longitudinal US assessment of labour in unselected nulliparous and multiparous women with fetal cephalic presentation. The secondary aims are to assess the sonopartogram differences in occiput anterior and posterior deliveries, to compare the labour trend from our research with the classic and other recent partogram models and to investigate the capability of the US labour monitoring to predict the outcome of spontaneous vaginal delivery. ETHICS AND DISSEMINATION All protocols and the informed consent form comply with the Ministry of Health and the professional society ethics guidelines. University ethics committees approved the study protocol. The trial results will be published in peer-reviewed journals and at the conference presentations. The study will be implemented and reported in line with the Strengthening the Reporting of Observational Studies in Epidemiology statement. TRIAL REGISTRATION NUMBER ClinicalTrials.gov Registry (NCT02326077).
Collapse
Affiliation(s)
- Laurentiu Mihai Dira
- Department of Obstetrics and Gynecology, University of Medicine and Pharmacy of Craiova, Craiova, Romania
| | - Stefania Tudorache
- Department of Obstetrics and Gynecology, University of Medicine and Pharmacy of Craiova, Craiova, Romania
| | | | - George Daskalakis
- Department of Obstetrics and Gynecology, University of Athens, Athens, Greece
| | - Dagklis Themistoklis
- Department of Obstetrics and Gynecology, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Smaranda Belciug
- Department of Computer Science, University of Craiova, Craiova, Romania
| | - Ruxandra Stoean
- Department of Computer Science, University of Craiova, Craiova, Romania
| | - Marius Novac
- Department of Intensive Care and Anesthesiology, University of Medicine and Pharmacy Craiova, Craiova, Romania
| | - Monica Laura Cara
- Department of Public Health, University of Medicine and Pharmacy Craiova, Craiova, Romania
| | - Roxana Dragusin
- Department of Obstetrics and Gynecology, University of Medicine and Pharmacy of Craiova, Craiova, Romania
| | - Maria Florea
- Department of Obstetrics and Gynecology, University of Medicine and Pharmacy of Craiova, Craiova, Romania
| | - Ciprian Patru
- Department of Obstetrics and Gynecology, University of Medicine and Pharmacy of Craiova, Craiova, Romania
| | - Lucian Zorila
- Department of Obstetrics and Gynecology, University of Medicine and Pharmacy of Craiova, Craiova, Romania
| | - Rodica Nagy
- Department of Obstetrics and Gynecology, University of Medicine and Pharmacy of Craiova, Craiova, Romania
| | - Dan Ruican
- Department of Obstetrics and Gynecology, University of Medicine and Pharmacy of Craiova, Craiova, Romania
| | - Dominic Gabriel Iliescu
- Department of Obstetrics and Gynecology, University of Medicine and Pharmacy of Craiova, Craiova, Romania
| |
Collapse
|
25
|
Ghi T. Intrapartum ultrasound and evidence-based medicine: a necessary but challenging marriage. Am J Obstet Gynecol MFM 2021; 3:100428. [PMID: 34303655 DOI: 10.1016/j.ajogmf.2021.100428] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Accepted: 06/21/2021] [Indexed: 02/07/2023]
Affiliation(s)
- Tullio Ghi
- Unit of Obstetrics and Gynecology, Department of Medicine and Surgery, University of Parma, Parma, Italy.
| |
Collapse
|
26
|
Kahrs BH, Eggebø TM. Intrapartum ultrasound in women with prolonged first stage of labor. Am J Obstet Gynecol MFM 2021; 3:100427. [PMID: 34273584 DOI: 10.1016/j.ajogmf.2021.100427] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 06/10/2021] [Accepted: 06/21/2021] [Indexed: 10/20/2022]
Abstract
The first stage of labor is from the start of active labor until the cervix is fully dilatated. To assess labor progress during this stage, a clinical examination has traditionally been done. The cervical dilatation, fetal head position, and fetal head station are evaluated. Moreover, these observations can be made with an ultrasound examination. Studies have shown that traditional clinical examinations are subjective, have poor reproducibility, and are unreliable. Ultrasound examinations of the fetal head station and fetal head position in the first stage of labor might predict labor outcome and mode of delivery and can help in decision making when prolonged first stage of labor is diagnosed.
Collapse
Affiliation(s)
- Birgitte Heiberg Kahrs
- National Center for Fetal Medicine, Trondheim University Hospital (St. Olav's University Hospital), Trondheim, Norway (Drs Kahrs and Eggebø); Department of Clinical and Molecular Medicine, Norwegian University of Science and Technology, Trondheim, Norway (Drs Kahrs and Eggebø).
| | - Torbjørn Moe Eggebø
- National Center for Fetal Medicine, Trondheim University Hospital (St. Olav's University Hospital), Trondheim, Norway (Drs Kahrs and Eggebø); Department of Clinical and Molecular Medicine, Norwegian University of Science and Technology, Trondheim, Norway (Drs Kahrs and Eggebø)
| |
Collapse
|
27
|
Intrapartum ultrasound and the choice between assisted vaginal and cesarean delivery. Am J Obstet Gynecol MFM 2021; 3:100439. [PMID: 34216834 DOI: 10.1016/j.ajogmf.2021.100439] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Revised: 06/25/2021] [Accepted: 06/25/2021] [Indexed: 11/24/2022]
Abstract
Inaccurate assessment of the fetal head position and station might increase the risk for difficult or failed assisted vaginal delivery. Compared with digital vaginal examination, an ultrasound examination is objective and more accurate. The International Society of Ultrasound in Obstetrics and Gynecology has issued practical guidelines on intrapartum ultrasound in 2018 and recommended that an ultrasound assessment should be conducted when there is suspected delay or arrest of the first or second stage of labor or before considering assisted vaginal delivery. Fetal head position is assessed transabdominally by identifying the fetal occiput, orbit, or midline cerebral echo. Studies have shown that ultrasound assessment improved the correct diagnosis of fetal head position and accuracy of instrument placement, however, it did not reduce morbidity. Studies on ultrasound assessment of asynclitism are limited but show promising results. Fetal head station is assessed transperineally in the midsagittal or axial plane. Of the various ultrasound parameters, angle of progression and head-perineum distance are the most widely studied and found to be highly correlated with the clinical fetal head station. An angle of progression of 120° correlates with a clinical head station of 0 and is an important landmark for engagement of successful vaginal delivery, whereas an angle of progression of 145° correlates with a clinical head station of ≥+2 and has been associated with successful assisted vaginal delivery. In contrast, a head perineum distance of ≥40 mm has been associated with an increased risk for difficult assisted vaginal delivery. A "head-up" direction of descent assessed transperineally in sagittal plane is also a favorable factor for successful vaginal delivery. Current evidence seems to suggest that a prediction model with >1 sonographic parameter performed better than a model that only used 1 parameter. We suggest that an algorithm model incorporating both clinical and sonographic parameters would be useful in guiding clinicians on their decision for assisted vaginal delivery.
Collapse
|
28
|
Hjartardóttir H, Lund SH, Benediktsdóttir S, Geirsson RT, Eggebø TM. Can ultrasound on admission in active labor predict labor duration and a spontaneous delivery? Am J Obstet Gynecol MFM 2021; 3:100383. [PMID: 33901721 DOI: 10.1016/j.ajogmf.2021.100383] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Revised: 04/15/2021] [Accepted: 04/19/2021] [Indexed: 11/28/2022]
Abstract
BACKGROUND Identifying predictive factors for a normal outcome at admission in the labor ward would be of value for planning labor care, timing interventions, and preventing labor dystocia. Clinical assessments of fetal head station and position at the start of labor have some predictive value, but the value of ultrasound methods for this purpose has not been investigated. Studies using transperineal ultrasound before labor onset show possibilities of using these methods to predict outcomes. OBJECTIVE This study aimed to investigate whether ultrasound measurements during the first examination in the active phase of labor were associated with the duration of labor phases and the need for operative delivery. STUDY DESIGN This was a secondary analysis of a prospective cohort study at Landspitali University Hospital, Reykjavík, Iceland. Nulliparous women at ≥37 weeks' gestation with a single fetus in cephalic presentation and in active spontaneous labor were eligible for the study. The recruitment period was from January 2016 to April 2018. Women were examined by a midwife on admission and included in the study if they were in active labor, which was defined as regular contractions with a fully effaced cervix, dilatation of ≥4 cm. An ultrasound examination was performed by a separate examiner within 15 minutes; both examiners were blinded to the other's results. Transabdominal and transperineal ultrasound examinations were used to assess fetal head position, cervical dilatation, and fetal head station, expressed as head-perineum distance and angle of progression. Duration of labor was estimated as the hazard ratio for spontaneous delivery using Kaplan-Meier curves and Cox regression analysis. The hazard ratios were adjusted for maternal age and body mass index. The associations between study parameters and mode of delivery were evaluated using receiver operating characteristic curves. RESULTS Median times to spontaneous delivery were 490 minutes for a head-perineum distance of ≤45 mm and 682 minutes for a head-perineum distance of >45 mm (log-rank test, P=.009; adjusted hazard ratio for a shorter head-perineum distance, 1.47 [95% confidence interval, 0.83-2.60]). The median durations were 506 minutes for an angle of progression of ≥93° and 732 minutes for an angle of progression of <93° (log-rank test, P=.008; adjusted hazard ratio, 2.07 [95% confidence interval, 1.15-3.72]). The median times to delivery were 506 minutes for nonocciput posterior positions and 677 minutes for occiput posterior positions (log-rank test, P=.07; adjusted hazard ratio, 1.52 [95% confidence interval, 0.96-2.38]) Median times to delivery were 429 minutes for a dilatation of ≥6 cm and 704 minutes for a dilatation of 4 to 5 cm (log-rank test, P=.002; adjusted hazard ratio, 3.11 [95% confidence interval, 1.68-5.77]). Overall, there were 75 spontaneous deliveries; among those deliveries, 16 were instrumental vaginal deliveries (1 forceps delivery and 15 ventouse deliveries), and 8 were cesarean deliveries. Head-perineum distance and angle of progression were associated with a spontaneous delivery with area under the receiver operating characteristic curves of 0.68 (95% confidence interval, 0.55-0.80) and 0.67 (95% confidence interval, 0.55-0.80), respectively. Ultrasound measurement of cervical dilatation or position at inclusion was not significantly associated with spontaneous delivery. CONCLUSION Ultrasound examinations showed that fetal head station and cervical dilatation were associated with the duration of labor; however, measurements of fetal head station were the variables best associated with operative deliveries.
Collapse
Affiliation(s)
- Hulda Hjartardóttir
- Department of Obstetrics and Gynecology, Landspitali University Hospital, Reykjavík, Iceland (Drs Hjartardóttir, Benediktsdóttir, and Geirsson); Faculty of Medicine, University of Iceland, Reykjavík, Iceland (Drs Hjartardóttir, Benediktsdóttir, and Geirsson).
| | | | - Sigurlaug Benediktsdóttir
- Department of Obstetrics and Gynecology, Landspitali University Hospital, Reykjavík, Iceland (Drs Hjartardóttir, Benediktsdóttir, and Geirsson); Faculty of Medicine, University of Iceland, Reykjavík, Iceland (Drs Hjartardóttir, Benediktsdóttir, and Geirsson)
| | - Reynir T Geirsson
- Department of Obstetrics and Gynecology, Landspitali University Hospital, Reykjavík, Iceland (Drs Hjartardóttir, Benediktsdóttir, and Geirsson); Faculty of Medicine, University of Iceland, Reykjavík, Iceland (Drs Hjartardóttir, Benediktsdóttir, and Geirsson)
| | - Torbjørn M Eggebø
- National Center for Fetal Medicine, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway (Dr Eggebø); Department of Obstetrics and Gynecology, Stavanger University Hospital, Stavanger, Norway (Dr Eggebø); Department of Clinical and Molecular Medicine, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway (Dr Eggebø)
| |
Collapse
|
29
|
Hjartardóttir H, Lund SH, Benediktsdóttir S, Geirsson RT, Eggebø TM. Fetal descent in nulliparous women assessed by ultrasound: a longitudinal study. Am J Obstet Gynecol 2021; 224:378.e1-378.e15. [PMID: 33039395 DOI: 10.1016/j.ajog.2020.10.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Revised: 09/25/2020] [Accepted: 10/02/2020] [Indexed: 12/24/2022]
Abstract
BACKGROUND Ultrasound measurements offer objective and reproducible methods to measure the fetal head station. Before these methods can be applied to assess labor progression, the fetal head descent needs to be evaluated longitudinally in well-defined populations and compared with the existing data derived from clinical examinations. OBJECTIVE This study aimed to use ultrasound measurements to describe the fetal head descent longitudinally as labor progressed through the active phase in nulliparous women with spontaneous onset of labor. STUDY DESIGN This was a single center, prospective cohort study at the Landspitali - The National University Hospital of Iceland, Reykjavik, Iceland, from January 2016 to April 2018. Nulliparous women with a single fetus in cephalic presentation and spontaneous labor onset at a gestational age of ≥37 weeks, were eligible. Participant inclusion occurred during admission for women with an established active phase of labor or at the start of the active phase for women admitted during the latent phase. The active phase was defined as an effaced cervix dilated to at least 4 cm in women with regular contractions. According to the clinical protocol, vaginal examinations were done at entry and subsequently throughout labor, paired each time with a transperineal ultrasound examination by a separate examiner, with both examiners being blinded to the other's results. The measurements used to assess the fetal head station were the head-perineum distance and angle of progression. Cervical dilatation was examined clinically. RESULTS The study population comprised 99 women. The labor patterns for the head-perineum distance, angle of progression, and cervical dilatation differentiated the participants into 75 with spontaneous deliveries, 16 with instrumental vaginal deliveries, and 8 cesarean deliveries. At the inclusion stage, the cervix was dilated 4 cm in 26 of the women, 5 cm in 30 of the women, and ≥6 cm in 43 women. One cesarean and 1 ventouse delivery were performed for fetal distress, whereas the remaining cesarean deliveries were conducted because of a failure to progress. The total number of examinations conducted throughout the study was 345, with an average of 3.6 per woman. The ultrasound-measured fetal head station both at the first and last examination were associated with the delivery mode and remaining time of labor. In spontaneous deliveries, rapid head descent started around 4 hours before birth, the descent being more gradual in instrumental deliveries and absent in cesarean deliveries. A head-perineum distance of 30 mm and angle of progression of 125° separately predicted delivery within 3.0 hours (95% confidence interval, 2.5-3.8 hours and 2.4-3.7 hours, respectively) in women delivering vaginally. Although the head-perineum distance and angle of progression are independent methods, both methods gave similar mirror image patterns. The fetal head station at the first examination was highest for the fetuses in occiput posterior position, but the pattern of rapid descent was similar for all initial positions in spontaneously delivering women. Oxytocin augmentation was used in 41% of women; in these labors a slower descent was noted. Descent was only slightly slower in the 62% of women who received epidural analgesia. A nonlinear relationship was observed between the fetal head station and dilatation. CONCLUSION We have established the ultrasound-measured descent patterns for nulliparous women in spontaneous labor. The patterns resemble previously published patterns based on clinical vaginal examinations. The ultrasound-measured fetal head station was associated with the delivery mode and remaining time of labor.
Collapse
|
30
|
Messina MP, Piccioni MG, Petrella C, Vitali M, Greco A, Ralli M, Ceccanti M, Ferraguti G, Neri I, Ricchi A, Fiore M, D'Angelo A. Advanced midwifery practice: intrapartum ultrasonography to assess fetal head station and comparison with vaginal digital examination. Minerva Obstet Gynecol 2021; 73:253-260. [PMID: 33851805 DOI: 10.23736/s2724-606x.21.04687-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Vaginal digital examination is considered the gold standard to evaluate patients during labor and delivery. However, transperineal ultrasound has been suggested as an effective tool in determining fetal head station during labor. Angle of progression (AOP), head-perineal distance (HPD) and head-symphysis distance (HSD) are reliable parameters to assess fetal head station during labor. The study aims were to evaluate how midwives can use AOP, HSD, HPD to assess the accuracy of digital vaginal exploration limited to the fetal head station. METHODS Trained midwives for ultrasound analyses performed transperineal ultrasounds during the first stage of labor with 2D-convex probe in 62 pregnant women at term with a single fetus in cephalic presentation. Immediately before the intrapartum ultrasound, the birth attendant performed a digital examination to assess cervical dilatation and head station. The ultrasound scans were compared to the digital vaginal examination through the Tutschek's formula. RESULTS AOP was wider in women who delivered vaginally without any complication if compared to "complicated delivery" group. HPD and HSD were greater in women who underwent an operative vaginal delivery or caesarean section. The vaginal exploration accuracy was 34%, but when ±1 cm was considered as tolerated, the overall accuracy was 74.19%. CONCLUSIONS Midwives may include ultrasounds in their clinical practice after adequate training or under the supervision of an ultrasound professional as an adjunct tool during labor to evaluate its progress and prevent any deviation from physiology.
Collapse
Affiliation(s)
- Marisa P Messina
- Department of Gynecology, Obstetrics and Urology, Sapienza University, Rome, Italy
| | - Maria G Piccioni
- Department of Gynecology, Obstetrics and Urology, Sapienza University, Rome, Italy
| | - Carla Petrella
- Institute of Biochemistry and Cell Biology (IBBC-CNR), Rome, Italy
| | | | - Antonio Greco
- Department of Sense Organs, Sapienza University, Rome, Italy
| | - Massimo Ralli
- Department of Sense Organs, Sapienza University, Rome, Italy
| | - Mauro Ceccanti
- SIFASD - Italian Society for the Study of Fetal Alcohol Spectrum Disorder, Rome, Italy
| | | | - Isabella Neri
- University of Modena and Reggio Emilia, Modena, Italy
| | - Alba Ricchi
- University of Modena and Reggio Emilia, Modena, Italy
| | - Marco Fiore
- Institute of Biochemistry and Cell Biology (IBBC-CNR), Rome, Italy - marcofiore.roma @gmail.com.,Department of Sense Organs, Sapienza University, Rome, Italy
| | - Alessio D'Angelo
- Department of Gynecology, Obstetrics and Urology, Sapienza University, Rome, Italy
| |
Collapse
|
31
|
Bardin R, Krispin E, Salman L, Navon I, Shmueli A, Perlman S, Gilboa Y, Hadar E. Association of term isolated microcephaly with mode of delivery and perinatal outcome - a retrospective case-control analysis. BMC Pregnancy Childbirth 2021; 21:115. [PMID: 33563226 PMCID: PMC7871588 DOI: 10.1186/s12884-021-03613-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 02/02/2021] [Indexed: 11/10/2022] Open
Abstract
Background We aimed to evaluate the association of isolated fetal microcephaly measured by ultrasound prior to delivery at term with mode of delivery and perinatal outcome. Methods A single-center retrospective study was conducted in 2012–2016. Fetal microcephaly was defined as head circumference > 2 standard deviations of the mean for gestational age and sex. We compared the obstetric, delivery, and outcome parameters of women in whom ultrasound performed up to 10 days prior to term delivery showed isolated fetal microcephaly (study group) or normal head circumference (reference group). Exclusion criteria were intrauterine fetal death, birthweight below the 10th percentile, and antepartum cesarean delivery for any indication. Results Of 3677 women included in the study, 26 (0.7%) had a late ultrasound finding of isolated fetal microcephaly. Baseline characteristics were similar in the two groups except for estimated fetal weight based on abdominal circumference and biparietal diameter, which was lower in the microcephaly group (3209.8 ± 557.6 vs. 2685.8 ± 420.8 g, p < .001). There was no significant between-group difference in rate of vaginal operative deliveries (11.7% vs 14.8%, respectively, p = 0.372). The study group had no intrapartum cesarean deliveries compared to 6.3% of the reference group (NS). Compared to controls, neonates in the study group were smaller (3323.2 ± 432.2 vs. 2957.0 ± 330.4 g, p < .001), with lower birthweight percentile (60.5 ± 26.5 vs. 33.6 ± 21.5%, p < .001) and were more often males (48.2 vs. 90.0%, p < .001). No significant differences were noted in perinatal outcomes between the groups, including admission to neonatal intensive care unit, intraventricular hemorrhage, 5-min Apgar score < 7, asphyxia, seizures, and sepsis. Conclusions Isolated microcephaly in term fetuses is not advantageous for a vaginal delivery, nor does it does not pose a greater than normal risk of adverse perinatal outcome.
Collapse
Affiliation(s)
- Ron Bardin
- Helen Schneider Hospital for Women, Rabin Medical Center, Petach Tikva; affiliated to Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
| | - Eyal Krispin
- Helen Schneider Hospital for Women, Rabin Medical Center, Petach Tikva; affiliated to Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Lina Salman
- Hillel Yaffe Medical Center, Hadera; affiliated to Rappaport Faculty of Medicine, Technion, Haifa, Israel
| | - Inbal Navon
- Helen Schneider Hospital for Women, Rabin Medical Center, Petach Tikva; affiliated to Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Anat Shmueli
- Helen Schneider Hospital for Women, Rabin Medical Center, Petach Tikva; affiliated to Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Sharon Perlman
- Helen Schneider Hospital for Women, Rabin Medical Center, Petach Tikva; affiliated to Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Yinon Gilboa
- Helen Schneider Hospital for Women, Rabin Medical Center, Petach Tikva; affiliated to Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Eran Hadar
- Helen Schneider Hospital for Women, Rabin Medical Center, Petach Tikva; affiliated to Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
32
|
Barros JG, Afonso M, Martins AT, Carita AI, Clode N, Ayres-de-Campos D, Graça LM. Transabdominal and transperineal ultrasound vs routine care before instrumental vaginal delivery - A randomized controlled trial. Acta Obstet Gynecol Scand 2021; 100:1075-1081. [PMID: 33319355 DOI: 10.1111/aogs.14065] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2020] [Revised: 12/09/2020] [Accepted: 12/10/2020] [Indexed: 11/29/2022]
Abstract
INTRODUCTION The role of intrapartum ultrasound as an ancillary method to instrumental vaginal delivery is yet to be determined. This study aimed to compare the use of transabdominal and transperineal ultrasound with routine clinical care before performing an instrumental vaginal delivery, regarding the incidence of adverse maternal and neonatal outcomes. MATERIAL AND METHODS A randomized controlled trial was conducted between October 2016 and March 2019 in two tertiary care maternity hospitals in Lisbon, Portugal. Women at term, with full cervical dilatation, singleton fetuses in cephalic presentation, and with an established indication for instrumental vaginal delivery, were approached for enrollment. After informed consent was obtained, randomization into one of two groups was carried out. In the experimental arm, women underwent transabdominal ultrasound for determination of the fetal head position and transperineal ultrasound for evaluation of the angle of progression, before instrumental vaginal delivery. In the control arm, no ultrasound was carried out before instrumental vaginal delivery. Primary outcomes were composite measures of maternal and neonatal morbidity. Composite maternal morbidity consisted of severe postpartum hemorrhage, perineal trauma, and prolonged hospital stay. Composite neonatal morbidity consisted of low 5-minute Apgar score, umbilical artery metabolic acidosis, birth trauma, and neonatal intensive care unit admission. RESULTS A total of 222 women were enrolled (113 in the experimental arm and 109 in the control arm). No significant differences between the two arms were found in composite measures of maternal (23.9% in the experimental group vs 22.9% in the control group, odds ratio 1.055, 95% CI 0.567-1.964) or neonatal morbidity (9.7% in the experimental group vs 6.4% in the control group, odds ratio 1.571, 95% CI 0.586-4.215), nor in any of the individual outcomes. CONCLUSIONS In this small randomized controlled trial that was stopped for futility before reaching the required sample size, transabdominal and transperineal ultrasound performed just before instrumental vaginal delivery did not reduce the incidence of adverse maternal and neonatal outcomes, when compared with routine clinical care.
Collapse
Affiliation(s)
- Joana G Barros
- Department of Obstetrics and Gynecology, Santa Maria University Hospital, Lisbon, Portugal
| | - Maria Afonso
- Department of Obstetrics and Gynecology, Santa Maria University Hospital, Lisbon, Portugal
| | - Ana T Martins
- Department of Obstetrics, Dr Alfredo da Costa Maternity Hospital, Lisbon, Portugal
| | - Ana I Carita
- Faculty of Human Motricity, University of Lisbon, Interdisciplinary Center of Human Perfomance, Biolad, Lisbon, Portugal
| | - Nuno Clode
- Department of Obstetrics and Gynecology, Santa Maria University Hospital, Lisbon, Portugal
| | - Diogo Ayres-de-Campos
- Department of Obstetrics and Gynecology, Santa Maria University Hospital, Lisbon, Portugal.,Faculty of Medicine, University of Lisbon, Lisbon, Portugal
| | - Luís M Graça
- Faculty of Medicine, University of Lisbon, Lisbon, Portugal
| |
Collapse
|
33
|
di Pasquo E, Ramirez Zegarra R, Kiener AJO, Gobbi L, Dall'Asta A, Fieschi L, Cugini L, Copelli M, Frusca T, Ghi T. Usefulness of an Intrapartum Ultrasound Simulator (IUSim™) for Midwife Training: Results from an RCT. Fetal Diagn Ther 2020; 48:120-127. [PMID: 33296898 DOI: 10.1159/000512047] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Accepted: 10/05/2020] [Indexed: 11/19/2022]
Abstract
INTRODUCTION We conducted a randomized study to determine whether a training session on a dedicated simulator (IUSim™) would facilitate the midwives in learning the technique of transperineal intrapartum ultrasound. METHODS Following a 30-min multimedia presentation including images and videos on how to obtain and measure the angle of progression (AoP) and the head-perineum distance (HPD), 6 midwives with no prior experience in intrapartum ultrasound were randomly split into 2 groups: 3 of them were assigned to the "training group" and 3 to the "control group." The midwives belonging to the former group were taught to measure the 2 sonographic parameters during a 3-h practical session conducted on IUSim™ under the supervision of an expert obstetrician. In the following 3 months, all the 6 midwives were asked to independently perform transperineal ultrasound during their clinical practice and to measure on the acquired images either the AoP or the HPD. The sonographic images were examined in blind by the teaching obstetrician who assigned a 0-3 score to the image quality (IQS) and to the measurement quality (MQS). RESULTS A total of 48 ultrasound images (24 patients) from 5 midwives were acquired and included in the study analysis. A midwife of the "training group" declined participation after the practical session. Independently from the randomization group, the image quality score (IQS + MQS) was significantly higher for the HPD compared with the AoP (2.5 ± 0.66 vs. 1.79 ± 1.14; p = 0.01). In the training group, the MQS of either AoP (2.66 ± 0.5 vs.1.46 ± 1.45. p = 0.038) and the HPD (2.9 ± 0.33 vs. 1.87 ± 0.83 p = 0.002) was significantly higher in comparison with the control group, while the IQS of both measurements was comparable between the 2 groups (1.91 ± 1.24 vs. 2.25 ± 0.865; p = 0.28). CONCLUSION The use of a dedicated simulator may facilitate the midwives in learning how to measure the AoP and the HPD on transperineal ultrasound images.
Collapse
Affiliation(s)
- Elvira di Pasquo
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy
| | - Ruben Ramirez Zegarra
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy.,Frankfurt Oder Klinikum, Frankfurt, Germany
| | - Ariane J O Kiener
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy
| | - Laura Gobbi
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy
| | - Andrea Dall'Asta
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy
| | - Laura Fieschi
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy
| | - Lodovica Cugini
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy
| | - Monica Copelli
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy
| | - Tiziana Frusca
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy
| | - Tullio Ghi
- Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy,
| |
Collapse
|
34
|
Abstract
Safe management of the second stage of labor is important. Wait for spontaneous delivery, operative vaginal deliveries and second stage cesarean sections are all options when prolonged second stage occurs. The important question is which option to choose. Fetal head station and fetal head position are used to decide mode of delivery; this has traditionally been decided by performing a digital vaginal examination. Studies have shown that theses clinical examinations of both fetal head station and position are unreliable and that ultrasound might be better option. The International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) published in 2018 guidelines on intrapartum ultrasound and recommends that ultrasound is performed for ascertainment of fetal head position and station before considering or performing an instrumental vaginal delivery for slow progress or arrested labor in the second stage. The determination of the fetal head position, fetal head station and the movement of the fetal head can easily be determined with the help of ultrasound and can help the clinicians in making the right decision on how to proceed when prolonged second stage of labor is diagnosed.
Collapse
Affiliation(s)
- Birgitte H Kahrs
- National Center for Fetal Medicine, Trondheim University Hospital (St Olavs Hospital), Trondheim, Norway - .,Department of Clinical and Molecular Medicine, Norwegian University of Science and Technology, Trondheim, Norway -
| |
Collapse
|
35
|
Intrapartum ultrasound at the initiation of the active second stage of labor predicts spontaneous vaginal delivery. Am J Obstet Gynecol MFM 2020; 3:100249. [PMID: 33451615 DOI: 10.1016/j.ajogmf.2020.100249] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Accepted: 09/26/2020] [Indexed: 12/27/2022]
Abstract
BACKGROUND Longer duration of active pushing during labor is associated with a higher rate of operative delivery and an increased risk of maternal and neonatal complications. Although immediate pushing at complete dilatation is associated with lower rates of chorioamnionitis and postpartum hemorrhage, it is also associated with a longer duration of pushing. OBJECTIVE This study aimed to evaluate whether fetal head station and position, as assessed by ultrasound at the beginning of the pushing process, can predict the mode of delivery and duration of pushing in nulliparous women. STUDY DESIGN This prospective observational study included nulliparous women with neuraxial analgesia and complete cervical dilatation. The following sonographic parameters were assessed just before the beginning of the pushing process, at rest, and while pushing during contraction: head position, angle of progression, head-perineum distance, and head-symphysis distance. The change between rest and pushing was designated as delta angle of progression, delta head-perineum distance, and delta head-symphysis distance. The sonographic measurements and fetal head station assessed by vaginal examination were compared between women who had a spontaneous vaginal delivery to those who underwent an operative delivery, and between those who pushed for more or less than 1 hour. RESULTS Of the 197 women included in this study, 166 (84.3%) had a spontaneous vaginal delivery, 31 (15.7%) had an operative delivery, 23 (11.6%) had a vacuum delivery, and 8 (4.0%) had a cesarean delivery. Spontaneous vaginal delivery and shorter duration of pushing (less than an hour) were significantly more common with a nonocciput posterior position (10.6% vs 47.3%; P<.005), a wider angle of progression, a shorter head-perineum distance and head-symphysis distance (both during rest and while pushing), and a lower fetal head station as assessed by digital vaginal examination. However, a logistic regression model revealed that only the angle of progression at rest and the delta angle of progression were independently associated with a spontaneous vaginal delivery with an area under the curve of 0.82 (95% confidence interval, 0.76-0.87; P<.0001) and 0.75 (95% confidence interval, 0.67-0.79; P<.0001), respectively. CONCLUSION Ultrasound performed at the beginning of the active second stage of labor can assist in predicting the mode of delivery and duration of pushing and perform better than the traditional digital examination, with the angle of progression at rest and delta angle of progression being the best predictors.
Collapse
|
36
|
Angeli L, Conversano F, Dall'Asta A, Volpe N, Simone M, Di Pasquo E, Pignatelli D, Schera GBL, Di Paola M, Ricciardi P, Ferretti A, Frusca T, Casciaro S, Ghi T. New technique for automatic sonographic measurement of change in head-perineum distance and angle of progression during active phase of second stage of labor. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2020; 56:597-602. [PMID: 31909525 DOI: 10.1002/uog.21963] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 12/27/2019] [Accepted: 12/29/2019] [Indexed: 06/10/2023]
Abstract
OBJECTIVE To evaluate the performance of a new ultrasound technique for the automatic assessment of the change in head-perineum distance (delta-HPD) and angle of progression (delta-AoP) during the active phase of the second stage of labor. METHODS This was a prospective observational cohort study including singleton term pregnancies with fetuses in cephalic presentation during the active phase of the second stage of labor. In each patient, two videoclips of 10 s each were acquired transperineally, one in the axial and one in the sagittal plane, between rest and the acme of an expulsive effort, in order to measure HPD and AoP, respectively. The videoclips were processed offline and the difference between the acme of the pushing effort and rest in HPD (delta-HPD) and AoP (delta-AoP) was calculated, first manually by an experienced sonographer and then using a new automatic technique. The reliability of the automatic algorithm was evaluated by comparing the automatic measurements with those obtained manually, which was considered as the reference gold standard. RESULTS Overall, 27 women were included. A significant correlation was observed between the measurements obtained by the automatic and the manual methods for both delta-HPD (intraclass correlation coefficient (ICC) = 0.97) and delta-AoP (ICC = 0.99). The high accuracy provided by the automatic algorithm was confirmed by the high values of the coefficient of determination (r2 = 0.98 for both delta-HPD and delta-AoP) and the low residual errors (root mean square error = 1.2 mm for delta-HPD and 1.5° for delta-AoP). A Bland-Altman analysis showed a mean difference of 0.52 mm (limits of agreement, -1.58 to 2.62 mm) for delta-HPD (P = 0.034) and 0.35° (limits of agreement, -2.54 to 3.09°) for delta-AoP (P = 0.39) between the manual and automatic measurements. CONCLUSIONS The automatic assessment of delta-AoP and delta-HPD during maternal pushing efforts is feasible. The automatic measurement of delta-AoP appears to be reliable when compared with the gold standard manual measurement by an experienced operator. Copyright © 2020 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- L Angeli
- Department of Medicine and Surgery, Obstetrics and Gynaecology Unit, University of Parma, Parma, Italy
| | - F Conversano
- National Research Council, Institute of Clinical Physiology, Lecce, Italy
| | - A Dall'Asta
- Department of Medicine and Surgery, Obstetrics and Gynaecology Unit, University of Parma, Parma, Italy
| | - N Volpe
- Department of Medicine and Surgery, Obstetrics and Gynaecology Unit, University of Parma, Parma, Italy
| | | | - E Di Pasquo
- Department of Medicine and Surgery, Obstetrics and Gynaecology Unit, University of Parma, Parma, Italy
| | - D Pignatelli
- National Research Council, Institute of Clinical Physiology, Lecce, Italy
| | - G B L Schera
- Department of Medicine and Surgery, Obstetrics and Gynaecology Unit, University of Parma, Parma, Italy
| | - M Di Paola
- National Research Council, Institute of Clinical Physiology, Lecce, Italy
| | - P Ricciardi
- Department of Medicine and Surgery, Obstetrics and Gynaecology Unit, University of Parma, Parma, Italy
| | - A Ferretti
- Department of Medicine and Surgery, Obstetrics and Gynaecology Unit, University of Parma, Parma, Italy
| | - T Frusca
- Department of Medicine and Surgery, Obstetrics and Gynaecology Unit, University of Parma, Parma, Italy
| | - S Casciaro
- National Research Council, Institute of Clinical Physiology, Lecce, Italy
| | - T Ghi
- Department of Medicine and Surgery, Obstetrics and Gynaecology Unit, University of Parma, Parma, Italy
| |
Collapse
|
37
|
Angeli L, Conversano F, Dall'Asta A, Eggebø T, Volpe N, Marta S, Pisani P, Casciaro S, Di Paola M, Frusca T, Ghi T. Automatic measurement of head-perineum distance during intrapartum ultrasound: description of the technique and preliminary results. J Matern Fetal Neonatal Med 2020; 35:2759-2764. [PMID: 32727248 DOI: 10.1080/14767058.2020.1799974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
OBJECTIVES To evaluate the accuracy and reliability of a new ultrasound technique for the automatic assessment of the head-perineum distance (HPD) during childbirth. METHODS HPD was measured on a total of 40 acquisition sessions in 30 laboring women both automatically by an innovative algorithm and manually by trained sonographers, assumed as gold standard. RESULTS A significant correlation was found between manual and automatic measurements (Intra-CC = 0.994). High values of the coefficient of determination (r2=0.98) and low residual errors: RMSE = 2.01 mm (4.9%) were found. CONCLUSION The automatic algorithm for the assessment of the HPD represents a reliable technique.
Collapse
Affiliation(s)
- Laura Angeli
- Department of Obstetrics and Gynecology, University Hospital of Parma, Parma, Italy
| | | | - Andrea Dall'Asta
- Department of Obstetrics and Gynecology, University Hospital of Parma, Parma, Italy
| | - Torbjørn Eggebø
- National Center for Fetal Medicine, Trondheim University Hospital (St. Olavs Hospital), Trondheim, Norway.,Department of Laboratory Medicine, Children's and Women's Health, Norwegian University of Science and Technology, Trondheim, Norway
| | - Nicola Volpe
- Department of Obstetrics and Gynecology, University Hospital of Parma, Parma, Italy
| | | | - Paola Pisani
- Institute of Clinical Physiology, National Council Research, Lecce, Italy
| | - Sergio Casciaro
- Institute of Clinical Physiology, National Council Research, Lecce, Italy
| | - Marco Di Paola
- Institute of Clinical Physiology, National Council Research, Lecce, Italy
| | - Tiziana Frusca
- Department of Obstetrics and Gynecology, University Hospital of Parma, Parma, Italy
| | - Tullio Ghi
- Department of Obstetrics and Gynecology, University Hospital of Parma, Parma, Italy
| |
Collapse
|
38
|
Frick A, Kostiv V, Vojtassakova D, Akolekar R, Nicolaides KH. Comparison of different methods of measuring angle of progression in prediction of labor outcome. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2020; 55:391-400. [PMID: 31692170 DOI: 10.1002/uog.21913] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Revised: 10/21/2019] [Accepted: 10/24/2019] [Indexed: 06/10/2023]
Abstract
OBJECTIVES First, to compare the manual sagittal and parasagittal and automated parasagittal methods of measuring the angle of progression (AoP) by transperineal ultrasound during labor, and, second, to develop models for the prediction of time to delivery and need for Cesarean section (CS) for failure to progress (FTP) in a population of patients undergoing induction of labor. METHODS This was a prospective observational study of transperineal ultrasound in a cohort of 512 women with a singleton pregnancy undergoing induction of labor. A random selection of 50 stored images was assessed for inter- and intraobserver reliability of AoP measurements using the manual sagittal and parasagittal and automated parasagittal methods. In cases of vaginal delivery, univariate linear, multiple linear and quantile regression analyses were performed to predict time to delivery. Univariate and multivariate binomial logistic regression analyses were performed to predict CS for FTP in the first stage of labor. RESULTS The intraclass correlation coefficient (ICC) for the manual parasagittal method for a single observer was 0.97 (95% CI, 0.95-0.98) and for two observers it was 0.96 (95% CI, 0.93-0.98), indicating good reliability. The ICC for the sagittal method for a single observer was 0.93 (95% CI, 0.88-0.96) and for two observers it was 0.74 (95% CI, 0.58-0.84), indicating moderate reliability for a single observer and poor reliability between two observers. Bland-Altman analysis demonstrated narrower limits of agreement for the manual parasagittal approach than for the sagittal approach for both a single and two observers. The automated parasagittal method failed to capture an image in 19% of cases. The mean difference in AoP measurements between the sagittal and manual parasagittal methods was 11°. In pregnancies resulting in vaginal delivery, 54% of the variation in time to delivery was explained in a model combining parity, epidural and syntocinon use during labor and the sonographic findings of fetal head position and AoP. In the prediction of CS for FTP in the first stage of labor, a model which combined maternal factors with the sonographic measurements of AoP and estimated fetal weight was superior to one utilizing maternal factors alone (area under the receiver-operating-characteristics curve, 0.80 vs 0.76). CONCLUSIONS First, the method of measuring AoP with the greatest reliability is the manual parasagittal technique and future research should focus on this technique. Second, over half of the variation in time to vaginal delivery can be explained by a model that combines maternal factors, pregnancy characteristics and ultrasound findings. Third, the ability of AoP to provide clinically useful prediction of CS for FTP in the first stage of labor is limited. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- A Frick
- Harris Birthright Research Centre for Fetal Medicine, King's College Hospital, London, UK
| | - V Kostiv
- Harris Birthright Research Centre for Fetal Medicine, King's College Hospital, London, UK
- Fetal Medicine Unit, Medway Maritime Hospital, Gillingham, UK
| | - D Vojtassakova
- Harris Birthright Research Centre for Fetal Medicine, King's College Hospital, London, UK
- Fetal Medicine Unit, Medway Maritime Hospital, Gillingham, UK
| | - R Akolekar
- Fetal Medicine Unit, Medway Maritime Hospital, Gillingham, UK
- Institute of Medical Sciences, Canterbury Christ Church University, Chatham, UK
| | - K H Nicolaides
- Harris Birthright Research Centre for Fetal Medicine, King's College Hospital, London, UK
| |
Collapse
|
39
|
Peng F, Yu Y, Sun Y, Jiang S, Han Y, Zhang Z. Using transperineal ultrasound to predict labor onset. ANNALS OF TRANSLATIONAL MEDICINE 2020; 7:718. [PMID: 32042734 DOI: 10.21037/atm.2019.12.11] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background Accurate diagnosis of labor onset is especially important for the counseling about elective induction of labor. The study aimed to evaluate whether transperineal ultrasound could better predict the timing and likelihood of spontaneous labor at term. Methods This single-center study was conducted between 2018 and 2019.Data on singleton pregnant women after 39 weeks and before labor onset were retrospectively reviewed. Results All the transperineal ultrasound parameters were well reproducible between the two doctors [intraclass correlation coefficient (ICC) for progression distance(PD) was 0.892, P<0.001], [ICC for angle of progression (AoP) was 0.881, P<0.001], [ICC for subpubic arch angle (SPA) was 0.766, P<0.001], [ICC for width of symphysis pubis (WSP) was 0.803, P<0.001]. For the pregnant women before 40 weeks, the width of symphysis pubis changed gradually with the of spontaneous labor (WSP) (r=0.33, P<0.05). For all included women, the SPA correlated with the time of spontaneous labor (SPA) (r=0.31, P<0.05). Conclusions The antepartum transperineal ultrasound is a simple and objective technique that better observes the initiation of labor. And with the WSP and SPA we were able to predict labor onset and help in counseling about elective induction of labor.
Collapse
Affiliation(s)
- Fanghua Peng
- Pelvic Floor Research Group, Department of Ultrasound and Tianjin Key Laboratory of Human Development and Reproductive Regulation, Tianjin Central Hospital of Gynecology Obstetrics, Tianjin 300100, China
| | - Yang Yu
- Pelvic Floor Research Group, Department of Ultrasound and Tianjin Key Laboratory of Human Development and Reproductive Regulation, Tianjin Central Hospital of Gynecology Obstetrics, Tianjin 300100, China
| | - Yanan Sun
- Pelvic Floor Research Group, Department of Ultrasound and Tianjin Key Laboratory of Human Development and Reproductive Regulation, Tianjin Central Hospital of Gynecology Obstetrics, Tianjin 300100, China
| | - Shan Jiang
- Pelvic Floor Research Group, Department of Ultrasound and Tianjin Key Laboratory of Human Development and Reproductive Regulation, Tianjin Central Hospital of Gynecology Obstetrics, Tianjin 300100, China
| | - Yun Han
- Pelvic Floor Research Group, Department of Ultrasound and Tianjin Key Laboratory of Human Development and Reproductive Regulation, Tianjin Central Hospital of Gynecology Obstetrics, Tianjin 300100, China
| | - Zhikun Zhang
- Pelvic Floor Research Group, Department of Ultrasound and Tianjin Key Laboratory of Human Development and Reproductive Regulation, Tianjin Central Hospital of Gynecology Obstetrics, Tianjin 300100, China
| |
Collapse
|
40
|
Dall’Asta A, Angeli L, Masturzo B, Volpe N, Schera GBL, Di Pasquo E, Girlando F, Attini R, Menato G, Frusca T, Ghi T. Prediction of spontaneous vaginal delivery in nulliparous women with a prolonged second stage of labor: the value of intrapartum ultrasound. Am J Obstet Gynecol 2019; 221:642.e1-642.e13. [PMID: 31589867 DOI: 10.1016/j.ajog.2019.09.045] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Revised: 09/22/2019] [Accepted: 09/25/2019] [Indexed: 12/23/2022]
Abstract
BACKGROUND A limited number of studies have addressed the role of intrapartum ultrasound in the prediction of the mode of delivery in women with prolonged second stage of labor. OBJECTIVE The objective of the study was to evaluate the role of transabdominal and transperineal sonographic findings in the prediction of spontaneous vaginal delivery among nulliparous women with prolonged second stage of labor. STUDY DESIGN This was a 2-center prospective study conducted at 2 tertiary maternity units. Nulliparous women with a prolonged active second stage of labor, as defined by active pushing lasting more than 120 minutes, were eligible for inclusion. Transabdominal ultrasound to evaluate the fetal head position and transperineal ultrasound for the measurement of the midline angle, the head-perineum distance, and the head-symphysis distance were performed in between uterine contractions and maternal pushes. At transperineal ultrasound the angle of progression was measured at rest and at the peak of maternal pushing effort. The delta angle of progression was defined as the difference between the angle of progression measured during active pushing at the peak of maternal effort and the angle of progression at rest. The sonographic findings of women who had spontaneous vaginal delivery vs those who required obstetric intervention, either vacuum extraction or cesarean delivery, were evaluated and compared. RESULTS Overall, 109 were women included. Spontaneous vaginal delivery and obstetric intervention were recorded in 40 (36.7%) and 69 (63.3%) patients, respectively. Spontaneous vaginal delivery was associated with a higher rate of occiput anterior position (90% vs 53.2%, P < .0001), lower head-perineum distance and head-symphysis distance (33.2 ± 7.8 mm vs 40.1 ± 9.5 mm, P = .001, and 13.1 ± 4.6 mm vs 19.5 ± 8.4 mm, P < .001, respectively), narrower midline angle (29.6° ± 15.3° vs 54.2° ± 23.6°, P < .001) and wider angle of progression at the acme of the pushing effort (153.3° ± 19.8° vs 141.8° ± 25.7°, P = .02) and delta-angle of progression (17.3° ± 12.9° vs 12.5° ± 11.0°, P = .04). At logistic regression analysis, only the midline angle and the head-symphysis distance proved to be independent predictors of spontaneous vaginal delivery. More specifically, the area under the curve for the prediction of spontaneous vaginal delivery was 0.80, 95% confidence interval (0.69-0.92), P < .001, and 0.74, 95% confidence interval (0.65-0.83), P = .002, for the midline angle and for the head-symphysis distance, respectively. CONCLUSION Transabdominal and transperineal intrapartum ultrasound parameters can predict the likelihood of spontaneous vaginal delivery in nulliparous women with prolonged second stage of labor.
Collapse
|
41
|
Ludvigsen E, Skjeldestad FE. Station of the fetal head at complete cervical dilation impacts duration of second stage of labor. Eur J Obstet Gynecol Reprod Biol X 2019; 7:100100. [PMID: 32715290 PMCID: PMC7379142 DOI: 10.1016/j.eurox.2019.100100] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Revised: 10/23/2019] [Accepted: 10/23/2019] [Indexed: 11/19/2022] Open
Abstract
Objective To examine the association between station of the fetal head at complete cervical dilation and duration of second stage of labor, as well as prolonged second stage of labor, without and with the use of analgesia (EA). Study design We conducted a population-based retrospective cohort study of 3311 women with a singleton pregnancy, gestational age ≥ 370 weeks, and cephalic presentation. Station of the fetal head at complete cervical dilation was categorized as at the pelvic floor, beneath the ischial spines, but above the pelvic floor, and at or above the ischial spines. In logistic regression analysis, we defined prolonged second stage of labor as > 2 h without and > 3 h with EA in nulliparous women, and > 1 h and > 2 h, respectively, in parous women. Results Survival curves demonstrated longer durations of second stage of labor in nulliparous women and women with EA in each category of station of fetal head. The adjusted odds ratio of prolonged second stage of labor was 13.1 (95% confidence interval (CI): 8.5-20.1) times higher when the fetal head was beneath the ischial spines, but above the pelvic floor, and 32.9 (95% CI: 21.5-50.2) times higher when the fetal head was at or above the ischial spines compared to at the pelvic floor. Conclusion Station of the fetal head at complete cervical dilation was significantly associated with duration of second stage of labor.
Collapse
Affiliation(s)
- Elisabeth Ludvigsen
- Division of Surgery, Oncology and Women’s Health, University Hospital of North Norway, Norway
- Research Group Epidemiology of Chronic Diseases, Institute of Community Medicine, UiT the Arctic University of Norway, Tromsø, Norway
| | - Finn Egil Skjeldestad
- Research Group Epidemiology of Chronic Diseases, Institute of Community Medicine, UiT the Arctic University of Norway, Tromsø, Norway
- Corresponding author at: Department of Community Medicine, Research Group Epidemiology of Chronic Diseases, UiT, The Arctic University of Norway, Tromsø, N 7037, Norway.
| |
Collapse
|
42
|
Kahrs BH, Usman S, Ghi T, Youssef A, Torkildsen EA, Lindtjørn E, Østborg TB, Benediktsdottir S, Brooks L, Harmsen L, Salvesen KÅ, Lees CC, Eggebø TM. Descent of fetal head during active pushing: secondary analysis of prospective cohort study investigating ultrasound examination before operative vaginal delivery. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2019; 54:524-529. [PMID: 31115115 DOI: 10.1002/uog.20348] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Revised: 05/13/2019] [Accepted: 05/14/2019] [Indexed: 06/09/2023]
Abstract
OBJECTIVES To investigate if descent of the fetal head during active pushing is associated with duration of operative vaginal delivery, mode of delivery and neonatal outcome in nulliparous women with prolonged second stage of labor. METHODS This was a prospective cohort study of nulliparous women with prolonged second stage of labor, conducted between November 2013 and July 2016 in five European countries. Fetal head descent was measured using transperineal ultrasound. Head-perineum distance (HPD) was measured between contractions and on maximum contraction during active pushing, and the difference between these values (ΔHPD) was calculated. The main outcome was duration of operative vaginal delivery, estimated using survival analysis to calculate hazard ratios (HRs) for vaginal delivery, with values > 1 indicating a shorter duration. HR was adjusted for prepregnancy body mass index, maternal age, induction of labor, augmentation with oxytocin and use of epidural analgesia. Pregnancies were grouped according to ΔHPD quartile, and delivery mode and neonatal outcome were compared between groups. RESULTS The study population comprised 204 women. Duration of vacuum extraction was shorter with increasing ΔHPD. Estimated mean duration was 10.0, 9.0, 8.8 and 7.5 min in pregnancies with ΔHPD in the first to fourth quartiles, respectively, and the adjusted HR for vaginal delivery, using increasing ΔHPD as a continuous variable, was 1.04 (95% CI, 1.01-1.08). Mean ΔHPD was 7 mm (range, -10 to 37 mm). ΔHPD was either negative or ≤ 2 mm in the lowest quartile. In this group, 7/50 (14%) pregnancies were delivered by Cesarean section, compared with 8/154 (5%) of those with ΔHPD > 2 mm (P < 0.05). There was no significant association between umbilical artery pH < 7.10 or 5-min Apgar score < 7 and ΔHPD quartile. CONCLUSION Minimal or no fetal head descent during active pushing was associated with longer duration of operative vaginal delivery and higher frequency of Cesarean section in nulliparous women with prolonged second stage of labor. © 2019 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
Affiliation(s)
- B H Kahrs
- National Center for Fetal Medicine, Trondheim University Hospital (St Olavs Hospital), Trondheim, Norway
- Department of Clinical and Molecular Medicine, Norwegian University of Science and Technology, Trondheim, Norway
| | - S Usman
- Centre for Fetal Care, Queen Charlotte's and Chelsea Hospital, Imperial College Healthcare NHS Trust, London, UK
| | - T Ghi
- Parma University Hospital, Parma, Italy
| | - A Youssef
- St Orsola Malpighi University Hospital, Bologna, Italy
| | - E A Torkildsen
- Department of Obstetrics and Gynecology, Stavanger University Hospital, Stavanger, Norway
| | - E Lindtjørn
- Department of Obstetrics and Gynecology, Stavanger University Hospital, Stavanger, Norway
| | - T B Østborg
- Department of Obstetrics and Gynecology, Stavanger University Hospital, Stavanger, Norway
| | - S Benediktsdottir
- Department of Obstetrics and Gynecology, Clinical Sciences, Lund University, Lund, Sweden
- Department of Obstetrics and Gynecology, Landspitali University Hospital, Reykjavik, Iceland
| | - L Brooks
- Hvidovre University Hospital, Copenhagen, Denmark
| | - L Harmsen
- Hvidovre University Hospital, Copenhagen, Denmark
| | - K Å Salvesen
- National Center for Fetal Medicine, Trondheim University Hospital (St Olavs Hospital), Trondheim, Norway
- Department of Clinical and Molecular Medicine, Norwegian University of Science and Technology, Trondheim, Norway
| | - C C Lees
- Centre for Fetal Care, Queen Charlotte's and Chelsea Hospital, Imperial College Healthcare NHS Trust, London, UK
| | - T M Eggebø
- National Center for Fetal Medicine, Trondheim University Hospital (St Olavs Hospital), Trondheim, Norway
- Department of Clinical and Molecular Medicine, Norwegian University of Science and Technology, Trondheim, Norway
| |
Collapse
|
43
|
Tse WT, Chaemsaithong P, Chan WW, Kwan AH, Huang J, Appiah K, Chong KC, Poon LC. Labor progress determined by ultrasound is different in women requiring cesarean delivery from those who experience a vaginal delivery following induction of labor. Am J Obstet Gynecol 2019; 221:335.e1-335.e18. [PMID: 31153931 DOI: 10.1016/j.ajog.2019.05.040] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2019] [Revised: 05/22/2019] [Accepted: 05/24/2019] [Indexed: 12/28/2022]
Abstract
BACKGROUND The diagnosis of labor dystocia generally is determined by the deviation of labor progress, which is assessed by the use of a partogram. Recently, intrapartum transperineal ultrasound for the assessment of fetal head descent has been introduced to assess labor progress in the first stage of labor in a more objective and noninvasive way. OBJECTIVE The objective of the study was to determine the differences in labor progress by the use of serial transperineal ultrasound assessment of fetal head descent between women having vaginal and cesarean delivery. STUDY DESIGN This was a prospective longitudinal study performed in 315 women with singleton pregnancy who were undergoing labor induction at term between December 2016 and December 2017. Paired assessment of cervical dilation and fetal head station by vaginal examination and transperineal ultrasonographic assessment of parasagittal angle of progression and head-perineum distance were made serially after the commencement of labor induction. According to the hospital protocol, assessment was performed every 24 hours and 4 hours, respectively, during latent and active phases of labor. The researchers and the clinical team were blinded to each other's findings. The repeated measures data were analyzed by mixed effect models. To determine the effect of mode of delivery on the association between parasagittal angle of progression and head-perineum distance against fetal head station and cervical dilation, the significance of the interaction term between each mode of delivery and fetal head station or cervical dilation was determined, which accounted for parity and obesity. Area under receiver-operating characteristic curve was used to evaluate the performance of serial intrapartum sonography in predicting women with cesarean delivery because of failure to progress. RESULTS The total number of paired vaginal examination and ultrasound assessments was 1198, with a median of 3 per woman. The median assessment-to-assessment interval was 4.6 hours (interquartile range, 4.3-5.1 hours). Women who achieved vaginal delivery (n=261) had steeper slopes of parasagittal angle of progression and head-perineum distance against fetal head station and cervical dilation than those who achieved cesarean delivery (n=54). Objectively, an additional decrease of 5.11 and 1.37 degrees in parasagittal angle of progression was observed for an unit increase in fetal head station and cervical dilation, respectively, in women who required cesarean delivery (P<.01; P=.01), compared with women who achieved vaginal delivery, after taking account of repeated measures from individuals and confounding factors. The respective additional increases in head-perineum distance for a unit increase in fetal head station and cervical dilation were 0.27 cm (P<.01) and 0.12 cm (P<.01). A combination of maternal characteristics with the temporal changes of parasagittal angle of progression for an unit increase in fetal head station achieved an area under receiver-operating characteristic curve of 0.85 (95% confidence interval, 0.76-0.94), with sensitivity of 79% and specificity of 80%, for the prediction of women who required cesarean delivery because of failure to progress. CONCLUSION The differences in labor progress between vaginal and cesarean delivery have been illustrated objectively by serial intrapartum transperineal ultrasonographic assessment of fetal head descent. This tool is potentially predictive of women who will require cesarean delivery because of failure to progress.
Collapse
|
44
|
Carvalho Neto RH, Viana Junior AB, Moron AF, Araujo Júnior E, Carvalho FHC, Feitosa HN. Assessment of the angle of progression and distance perineum-head in the prediction of type of delivery and duration of labor using intrapartum ultrasonography. J Matern Fetal Neonatal Med 2019; 34:2340-2348. [PMID: 31505974 DOI: 10.1080/14767058.2019.1666818] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
OBJECTIVE To evaluate the relevance of the angle of progression (AOP) and head-perineum distance (HPD) for predicting the type of delivery and duration of the second stage of labor using intrapartum ultrasonography. METHODS In total, 221 women in labor with a single gestational sac at ≥37 weeks of gestation and fetuses in cephalic presentation underwent two-dimensional ultrasonography by transperineal route for measurements of AOP and HPD. Correlations between the type of delivery (vaginal or surgical (cesarean section and forceps)), duration of the second stage of labor, and fetal and maternal characteristics were assessed. AOP and HPD variables were separately studied in the first and second stages of labor. Multivariate logistic regression was followed in stages to identify the predictors for the surgical delivery outcome - stepwise forward method. RESULTS In total, 153 (69.2%) women underwent vaginal deliveries, 7 (3.2%) underwent forceps deliveries, and 61 (27.6%) underwent cesarean deliveries. AOP was a statistically significant parameter in first and second stages of labor (107.8 ± 12.1° versus 100.8 ± 13.7°; p = .017), with an inverse correlation with the occurrence of vaginal delivery. HPD was a statistically significant parameter in the second stage of labor (3.42 ± 0.84 cm versus 4.17 ± 0.54 cm; p < .003), with a direct correlation with the occurrence of surgical delivery. The value of AOP that optimized the curve was 129.9° with 85% specificity and 63% sensitivity for the vaginal delivery endpoint. The value of HPD that optimized the curve was 4.3 cm with 69% specificity and 89% sensitivity for the surgical delivery endpoint. In the first phase, the variables defining the type of delivery were the following: height, body mass index, and AOP. In the second phase, the variables defining were the following: height, labor analgesia, HPD, and position of the fetal occiput. CONCLUSION AOP and HPD determined by intrapartum ultrasonography were associated with duration of labor, which may aid in predicting the type of delivery in association with clinical parameters.
Collapse
Affiliation(s)
- Raimundo Homero Carvalho Neto
- Maternal Fetal Medicine Service, Assis Chateaubriand Maternity, Federal University of Ceará (UFC), Fortaleza, Brazil
| | - Antonio Brazil Viana Junior
- Maternal Fetal Medicine Service, Assis Chateaubriand Maternity, Federal University of Ceará (UFC), Fortaleza, Brazil
| | - Antonio Fernandes Moron
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo, Brazil
| | - Edward Araujo Júnior
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo, Brazil
| | | | - Helvécio Neves Feitosa
- Maternal Fetal Medicine Service, Assis Chateaubriand Maternity, Federal University of Ceará (UFC), Fortaleza, Brazil.,Department of Obstetrics and Gynecology, University of Fortaleza (UNIFOR), Fortaleza, Brazil
| |
Collapse
|
45
|
Ali J, Hebbar S. Ultrasound Assessment of Foetal Head-Perineum Distance Prior to Induction of Labour as a Predictor of Successful Vaginal Delivery. J Obstet Gynaecol India 2019; 69:129-135. [PMID: 30956466 DOI: 10.1007/s13224-018-1120-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Accepted: 03/30/2018] [Indexed: 01/04/2023] Open
Abstract
Background In modern obstetrical practice, incidence of induction of labour is on rise for varied maternal and foetal indications. Ultrasound can help obstetricians in counselling patients before induction of labour and explain the probability of successful induction. Objectives To study the role of foetal head-perineum distance in predicting successful vaginal delivery and to correlate with other parameters such as cervical length and Bishop score. Design This study is a prospective case-control study in a tertiary care teaching hospital. Population There were 250 term patients between 37 and 40+ weeks with singleton cephalic presentation with no contraindications for vaginal delivery. Methods Prior to induction of labour, transperineal ultrasound was performed to measure foetal head-perineum distance. Simultaneously, cervical length was performed using transvaginal ultrasound probe. Bishop score was determined at the same time by clinical examination. Main Outcome Measures Outcome of induction was considered successful when it resulted in vaginal delivery. It was considered to be a failure if patient did not get into active phase of labour or an operative intervention had to be performed because of non-progress of labour in active phase of labour. Cases were excluded if caesarean delivery had to be performed in the event of foetal distress. Results It was observed that as the transperineal foetal head-perineum distance decreased, the rate of vaginal delivery increased. Similarly, when foetal head-perineum distance increased, the rate of caesarean delivery increased. At a cut-off ≤ 5.5 cm, foetal head-perineum distance had a maximum predictability (sensitivity 97%, specificity 88.1%). Conclusion Transperineal foetal head-distance measured by ultrasound can be used as an important tool to predict vaginal delivery before induction of labour.
Collapse
Affiliation(s)
- Jijisha Ali
- Mediclinic Welcare Hospital, Garhoud, Dubai, United Arab Emirates
| | - Shripad Hebbar
- 2Kasturba Medical College, Manipal, Manipal Academy of Higher Education (MAHE), Manipal, India
| |
Collapse
|
46
|
Usman S, Kahrs B, Barton H, Salvesen K, Moe Eggebo T, Lees C. Time to delivery based on sonographic assessment prior to forceps and vacuum. Australas J Ultrasound Med 2019; 22:111-117. [PMID: 34760547 DOI: 10.1002/ajum.12121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Introduction To compare the duration of vacuum and forceps delivery in relation to ultrasound assessment of fetal head position and station. Methods A prospective single-centre cohort study in nulliparous women at term with prolonged second stage of labour. Fetal head position was determined using transabdominal ultrasound and station as head-perineum distance (HPD) from transperineal ultrasound prior to an instrument. The primary outcome was duration of vacuum and forceps to vaginal delivery and was analysed as survival expressed by hazard ratio (HR). Secondary outcomes were delivery mode and immediate neonatal outcome. Results In the study population of 54 women, the primary instrument was vacuum for 36 and forceps for 18. Four women were delivered by Caesarean section. Estimated median duration for forceps deliveries was 5 min (95% CI 4.0-6.0) vs. 9 min (95% CI 7.3-10.6) for vacuum deliveries (P = 0.17; Log-rank test). The HR for vaginal delivery was 2.02 (95% CI 1.04-3.91, P = 0.038) after adjusting for HPD, maternal age and BMI. OP position had minor influence on the primary outcome (HR changed from 2.02 to 2.08). The first instrument failed in 11/31 (35.5%) where HPD > 35 mm vs. 2/21 (9.5%) where HPD ≤ 35 mm (P < 0.05). There were no cases of Apgar score <7 at 5 min or umbilical artery pH < 7.1. Conclusion In prolonged second stage, delivery with forceps was achieved more quickly than by vacuum when matched for ultrasound determined head station. Irrespective of which was the primary instrument, the failure rate was greater at higher head stations.
Collapse
Affiliation(s)
- Sana Usman
- Department of Cancer and Surgery Institute of Reproductive Developmental Biology Hammersmith Campus Du Cane Road London W12 ONN UK.,Centre for Fetal Care Imperial College Healthcare NHS Trust Du Cane Road London W12 0HS UK
| | - Birgitte Kahrs
- National Center for Fetal Medicine St Olavs Hospital Trondheim University Hospital Prinsesse Kristinas Gate 3, 7030 Trondheim Norway.,Department of Clinical and Molecular Medicine Norwegian University of Science and Technology NO-7491 Trondheim Norway
| | - Helen Barton
- Department of Cancer and Surgery Institute of Reproductive Developmental Biology Hammersmith Campus Du Cane Road London W12 ONN UK
| | - Kjell Salvesen
- National Center for Fetal Medicine St Olavs Hospital Trondheim University Hospital Prinsesse Kristinas Gate 3, 7030 Trondheim Norway.,Department of Clinical and Molecular Medicine Norwegian University of Science and Technology NO-7491 Trondheim Norway
| | - Torbjorn Moe Eggebo
- National Center for Fetal Medicine St Olavs Hospital Trondheim University Hospital Prinsesse Kristinas Gate 3, 7030 Trondheim Norway.,Department of Clinical and Molecular Medicine Norwegian University of Science and Technology NO-7491 Trondheim Norway
| | - Christoph Lees
- Department of Cancer and Surgery Institute of Reproductive Developmental Biology Hammersmith Campus Du Cane Road London W12 ONN UK.,Centre for Fetal Care Imperial College Healthcare NHS Trust Du Cane Road London W12 0HS UK.,KU Leuven Oude Markt 13 3000 Leuven Belgium
| |
Collapse
|
47
|
Erlik U, Weissmann-Brenner A, Kivilevitch Z, Moran O, Kees S, Karp H, Perlman S, Achiron R, Gilboa Y. Head progression distance during the first stage of labor as a predictor for delivery outcome. J Matern Fetal Neonatal Med 2018; 33:380-384. [PMID: 30273066 DOI: 10.1080/14767058.2018.1493723] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
Objectives: To assess if measurement of the head progression distance (PD) during the first stage of labor in nulliparous women can predict the delivery method.Methods: A prospective study was conducted on consecutive nulliparous women beyond 37 week's gestation during the first stage of labor. Transperineal ultrasound was performed to assess the PD. Analysis was performed on the relationships between PD during rest and during voluntary pushing and the fetal and maternal characteristics, delivery mode, and immediate postnatal outcomes.Results: Eighty seven suitable nulliparous women were suitable for analysis. PD was found to be significantly longer in women who delivered vaginally (VD) compared to those who underwent a cesarean section (CS) for obstructed labor: PD at rest was 2.51 ± 1.71 cm in women who delivered vaginally compared to 1.48 ± 1.9 cm in women who delivered by CS (p = .01). The PD during pushing was 3.43 ± 1.8 cm for a VD compared to 1.5 ± 2.1 cm for CS (p = .015). Logistic regression and receiver-operating characteristics curve analysis demonstrated a moderate predictive value of PD with respect to the mode of delivery (area under the curve was 0.67 during both resting and pushing period).Conclusion: PD measurements during the first stage of labor among nulliparous women differ significantly both in rest and during pushing between patients who delivered vaginally compared to CS and can therefore assist in predicting the mode of delivery.
Collapse
Affiliation(s)
- Uri Erlik
- Ultrasound Unit, Department of Obstetrics and Gynecology, Lis Maternity Hospital, Tel Aviv Medical Center, Tel Aviv, Israel.,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Alina Weissmann-Brenner
- Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.,Antenatal Diagnostic Unit, Department of Obstetrics and Gynecology, Chaim Sheba Medical Center, Tel Hashomer, Israel
| | - Zvi Kivilevitch
- Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.,Antenatal Diagnostic Unit, Department of Obstetrics and Gynecology, Chaim Sheba Medical Center, Tel Hashomer, Israel
| | - Orit Moran
- Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.,Antenatal Diagnostic Unit, Department of Obstetrics and Gynecology, Chaim Sheba Medical Center, Tel Hashomer, Israel
| | - Salim Kees
- Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.,Antenatal Diagnostic Unit, Department of Obstetrics and Gynecology, Chaim Sheba Medical Center, Tel Hashomer, Israel
| | - Hila Karp
- Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.,Antenatal Diagnostic Unit, Department of Obstetrics and Gynecology, Chaim Sheba Medical Center, Tel Hashomer, Israel
| | - Sharon Perlman
- Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.,Antenatal Diagnostic Unit, Department of Obstetrics and Gynecology, Chaim Sheba Medical Center, Tel Hashomer, Israel
| | - Reuven Achiron
- Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.,Antenatal Diagnostic Unit, Department of Obstetrics and Gynecology, Chaim Sheba Medical Center, Tel Hashomer, Israel
| | - Yinon Gilboa
- Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.,Antenatal Diagnostic Unit, Department of Obstetrics and Gynecology, Chaim Sheba Medical Center, Tel Hashomer, Israel
| |
Collapse
|
48
|
Gilboa Y, Frenkel TI, Schlesinger Y, Rousseau S, Hamiel D, Achiron R, Perlman S. Visual biofeedback using transperineal ultrasound in second stage of labor. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2018; 52:91-96. [PMID: 29155474 DOI: 10.1002/uog.18962] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2017] [Revised: 10/29/2017] [Accepted: 11/09/2017] [Indexed: 06/07/2023]
Abstract
OBJECTIVE To assess the obstetric and psychological effects of visual biofeedback by transperineal ultrasound (TPU) during the second stage of labor. METHODS This was a prospective, single-center observational study of low-risk nulliparous women with epidural analgesia undergoing vaginal delivery. Visual biofeedback using TPU was provided to 26 women during the second stage of labor. Pushing efficacy was assessed by the change in the angle of progression (AoP) at rest and during pushing efforts, before and after biofeedback. Obstetric outcomes included incidence of perineal tearing, mode of delivery and length of second stage of labor. Psychological outcomes were assessed by self-reported measures obtained during the postnatal hospital stay and included measures of perceived control and maternal satisfaction with childbirth, as well as level of maternal feelings of connectedness with the newborn. Obstetric and psychological results were compared with those of a control group of 69 women who received standard obstetric coaching from midwives. RESULTS Pushing efficacy increased significantly following visual biofeedback by TPU (P = 0.01), as indicated by a significantly lower delta AoP before (mean, 22.2° (95% CI, 13.9-31.7°)) compared with after (mean, 35.2° (95% CI, 25.9-45.3°)) biofeedback. A significant association was found between visual biofeedback and an intact perineum following delivery (P = 0.03). No significant differences were found between the two groups with regard to mode of delivery or length of the second stage. Feelings of maternal connectedness with the newborn were significantly stronger (P = 0.003) in women who received visual biofeedback than in those who did not. However, perceived control during childbirth and maternal satisfaction with childbirth did not differ significantly between the biofeedback and control groups. CONCLUSIONS This pilot study suggests that biofeedback using TPU may serve as a complementary tool to coached maternal pushing during the second stage of labor, with obstetric as well as psychological benefits. Further studies are required to confirm our findings and define the optimal duration of the intervention. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- Y Gilboa
- Prenatal Diagnostic Unit, Department of Obstetrics and Gynecology, The Chaim Sheba Medical Center, Tel Ha-Shomer, Israel
- Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - T I Frenkel
- Ziama Arkin Infancy Institute, Interdisciplinary Center (IDC), Herzliya, Israel
- Baruch Ivcher School of Psychology, Interdisciplinary Center (IDC), Herzliya, Israel
| | - Y Schlesinger
- Ziama Arkin Infancy Institute, Interdisciplinary Center (IDC), Herzliya, Israel
- Baruch Ivcher School of Psychology, Interdisciplinary Center (IDC), Herzliya, Israel
| | - S Rousseau
- Ziama Arkin Infancy Institute, Interdisciplinary Center (IDC), Herzliya, Israel
- Baruch Ivcher School of Psychology, Interdisciplinary Center (IDC), Herzliya, Israel
| | - D Hamiel
- Baruch Ivcher School of Psychology, Interdisciplinary Center (IDC), Herzliya, Israel
- Cohen Harris Resilience Center, Tel Aviv, Israel
- Tel Aviv Brill Community Mental Health Center, Clalit Health Services, Israel
| | - R Achiron
- Prenatal Diagnostic Unit, Department of Obstetrics and Gynecology, The Chaim Sheba Medical Center, Tel Ha-Shomer, Israel
- Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - S Perlman
- Prenatal Diagnostic Unit, Department of Obstetrics and Gynecology, The Chaim Sheba Medical Center, Tel Ha-Shomer, Israel
- Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
49
|
Ghi T, Eggebø T, Lees C, Kalache K, Rozenberg P, Youssef A, Salomon LJ, Tutschek B. ISUOG Practice Guidelines: intrapartum ultrasound. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2018; 52:128-139. [PMID: 29974596 DOI: 10.1002/uog.19072] [Citation(s) in RCA: 144] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2018] [Revised: 03/08/2018] [Accepted: 03/16/2018] [Indexed: 06/08/2023]
Abstract
The purpose of these Guidelines is to review the published techniques of ultrasound in labor and their practical applications, to summarize the level of evidence regarding the use of ultrasound in labor and to provide guidance to practitioners on when ultrasound in labor is clinically indicated and how the sonographic findings may affect labor management. We do not imply or suggest that ultrasound in labor is a necessary standard of care.
Collapse
Affiliation(s)
- T Ghi
- Obstetrics and Gynecology, University of Parma, Parma, Italy
| | - T Eggebø
- National Center for Fetal Medicine, Trondheim University Hospital (St Olavs Hospital), Trondheim, Norway
- Department of Obstetrics and Gynecology, Stavanger University Hospital, Stavanger, Norway
| | - C Lees
- Centre for Fetal Care, Queen Charlottes and Chelsea Hospital, London, UK
| | - K Kalache
- Sidra Medical and Research Center, Doha, Qatar
| | - P Rozenberg
- Centre Hospitalier Poissy Saint Germain, Obstetrics & Gynaecology, Paris, France
| | - A Youssef
- Obstetrics and Gynecology, S. Orsola Malpighi Hospital, Bologna, Italy
| | - L J Salomon
- Hôpital Universitaire Necker-Enfants Malades, AP-HP, Université Paris Descartes, Maternité, Paris, France
- Société Française pour l'Amélioration des Pratiques Echographiques, SFAPE
| | - B Tutschek
- Prenatal Zurich, Heinrich-Heine-University, Medical Faculty, Zürich, Switzerland
| |
Collapse
|
50
|
Assessment of fetal head engagement with transperineal ultrasound: Searching for the cutoff level. J Gynecol Obstet Hum Reprod 2018; 47:317-324. [PMID: 29793035 DOI: 10.1016/j.jogoh.2018.05.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2018] [Revised: 05/13/2018] [Accepted: 05/17/2018] [Indexed: 11/21/2022]
Abstract
PURPOSE Engagement of the fetal head is a determinant element when deciding on operative vaginal delivery. In routine practice, engagement is a clinical diagnosis based on transvaginal digital examination. Transperineal ultrasound might provide complementary information useful for measuring the fetal head-perineum distance (HPD). The purpose of this work was to determine the cutoff HPD distinguishing engagement from non-engagement. MATERIALS AND METHODS This single-center prospective study approved by the institutional review board was conducted between December 25, 2012 and August 31, 2015 in 411 nulliparous women; 20 did not provide informed consent and were excluded; analysis concerned 391 patients. Clinical diagnosis - engagement or non-engagement depending on results of the transvaginal digital examination (Farabeuf's and Demelin's signs) - was compared with the ultrasound HPD measurement. RESULTS The clinical diagnosis was non-engagement at complete dilatation in 96 patients (24.6%). The cutoff HPD distinguishing between engagement and non-engagement was 57mm (AUC 83.5% [95%CI 79.3-87.8]), with 75.0% [65.5-82.6] sensitivity, 75.9% [70.7-80.5] specificity, 50.3% [42.2-58.4] positive predictive value, and 90.3% [86.0-93.4] negative predictive value. CONCLUSIONS In this series, the HPD cutoff distinguishing between engagement and non-engagement was 57mm. Below this cutoff level, the head should be considered engaged, beyond non-engaged. Nevertheless, the pertinence of this cutoff level is hampered by the imprecision of the gold standard used for the clinical diagnosis (transvaginal digital examination). In case of doubt, we recommend, in addition to considering the obstetrical setting, to combine transperineal ultrasound with transvaginal digital examination to avoid deleterious failure of operative vaginal delivery.
Collapse
|