1
|
Zhu XH, Lee BY, Chen W. Functional energetic responses and individual variance of the human brain revealed by quantitative imaging of adenosine triphosphate production rates. J Cereb Blood Flow Metab 2018; 38:959-972. [PMID: 29633649 PMCID: PMC5998995 DOI: 10.1177/0271678x18769039] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2017] [Revised: 02/13/2018] [Accepted: 03/12/2018] [Indexed: 01/13/2023]
Abstract
Cellular ATP energy metabolism and regulation are essential for brain function and health. Given the high ATP expenditure at resting-state, it is not yet clear how the human brain at working-state can effectively regulate ATP production to meet higher energy requirement. Through quantitative measurement of regional cerebral ATP production rates and associated neurophysiological parameters in human visual cortex at rest and during visual stimulation, we found significant stimulus-induced and highly correlated neuroenergetic changes, indicating distinctive and complementary roles of the ATP synthesis reactions in supporting evoked neuronal activity and maintaining ATP homeostasis. We also uncovered large individual variances in the neuroenergetic responses and significant reductions in intracellular [H+] and free [Mg2+] during the stimulation. These results provide new insights into the mechanism underlying the brain ATP energy regulation and present a sensitive and much-needed neuroimaging tool for quantitatively assessing neuroenergetic state in healthy and diseased human brain.
Collapse
Affiliation(s)
- Xiao-Hong Zhu
- Center for Magnetic Resonance Research (CMRR), Department of Radiology, University of Minnesota Medical School, Minneapolis, MN, USA
| | - Byeong-Yeul Lee
- Center for Magnetic Resonance Research (CMRR), Department of Radiology, University of Minnesota Medical School, Minneapolis, MN, USA
| | - Wei Chen
- Center for Magnetic Resonance Research (CMRR), Department of Radiology, University of Minnesota Medical School, Minneapolis, MN, USA
| |
Collapse
|
2
|
Zoelch N, Hock A, Henning A. Quantitative magnetic resonance spectroscopy at 3T based on the principle of reciprocity. NMR IN BIOMEDICINE 2018; 31:e3875. [PMID: 29465821 DOI: 10.1002/nbm.3875] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2017] [Revised: 10/06/2017] [Accepted: 11/10/2017] [Indexed: 05/22/2023]
Abstract
Quantification of magnetic resonance spectroscopy signals using the phantom replacement method requires an adequate correction of differences between the acquisition of the reference signal in the phantom and the measurement in vivo. Applying the principle of reciprocity, sensitivity differences can be corrected at low field strength by measuring the RF transmitter gain needed to obtain a certain flip angle in the measured volume. However, at higher field strength the transmit sensitivity may vary from the reception sensitivity, which leads to wrongly estimated concentrations. To address this issue, a quantification approach based on the principle of reciprocity for use at 3T is proposed and validated thoroughly. In this approach, the RF transmitter gain is determined automatically using a volume-selective power optimization and complemented with information from relative reception sensitivity maps derived from contrast-minimized images to correct differences in transmission and reception sensitivity. In this way, a reliable measure of the local sensitivity was obtained. The proposed method is used to derive in vivo concentrations of brain metabolites and tissue water in two studies with different coil sets in a total of 40 healthy volunteers. Resulting molar concentrations are compared with results using internal water referencing (IWR) and Electric REference To access In vivo Concentrations (ERETIC). With the proposed method, changes in coil loading and regional sensitivity due to B1 inhomogeneities are successfully corrected, as demonstrated in phantom and in vivo measurements. For the tissue water content, coefficients of variation between 2% and 3.5% were obtained (0.6-1.4% in a single subject). The coefficients of variation of the three major metabolites ranged from 3.4-14.5%. In general, the derived concentrations agree well with values estimated with IWR. Hence, the presented method is a valuable alternative for IWR, without the need for additional hardware such as ERETIC and with potential advantages in diseased tissue.
Collapse
Affiliation(s)
- Niklaus Zoelch
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
- Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland
- Hospital of Psychiatry, Department of Psychiatry, Psychotherapy and Psychosomatics, University of Zurich, Zurich, Switzerland
| | - Andreas Hock
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
- Hospital of Psychiatry, Department of Psychiatry, Psychotherapy and Psychosomatics, University of Zurich, Zurich, Switzerland
| | - Anke Henning
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
- Max Plank Institute for Biological Cybernetics, Tuebingen, Germany
| |
Collapse
|
3
|
Rackayova V, Cudalbu C, Pouwels PJW, Braissant O. Creatine in the central nervous system: From magnetic resonance spectroscopy to creatine deficiencies. Anal Biochem 2016; 529:144-157. [PMID: 27840053 DOI: 10.1016/j.ab.2016.11.007] [Citation(s) in RCA: 73] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2016] [Revised: 11/08/2016] [Accepted: 11/09/2016] [Indexed: 10/20/2022]
Abstract
Creatine (Cr) is an important organic compound acting as intracellular high-energy phosphate shuttle and in energy storage. While located in most cells where it plays its main roles in energy metabolism and cytoprotection, Cr is highly concentrated in muscle and brain tissues, in which Cr also appears to act in osmoregulation and neurotransmission. This review discusses the basis of Cr metabolism, synthesis and transport within brain cells. The importance of Cr in brain function and the consequences of its impaired metabolism in primary and secondary Cr deficiencies are also discussed. Cr and phosphocreatine (PCr) in living systems can be well characterized using in vivo magnetic resonance spectroscopy (MRS). This review describes how 1H MRS allows the measurement of Cr and PCr, and how 31P MRS makes it possible to estimate the creatine kinase (CK) rate constant and so detect dynamic changes in the Cr/PCr/CK system. Absolute quantification by MRS using creatine as internal reference is also debated. The use of in vivo MRS to study brain Cr in a non-invasive way is presented, as well as its use in clinical and preclinical studies, including diagnosis and treatment follow-up in patients.
Collapse
Affiliation(s)
- Veronika Rackayova
- Laboratory of Functional and Metabolic Imaging (LIFMET), Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Cristina Cudalbu
- Centre d'Imagerie Biomedicale (CIBM), Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Petra J W Pouwels
- Department of Physics and Medical Technology, VU University Medical Center, Amsterdam, The Netherlands
| | - Olivier Braissant
- Service of Biomedicine, Neurometabolic Unit, Lausanne University Hospital, Lausanne, Switzerland.
| |
Collapse
|
4
|
Deelchand DK, Nguyen TM, Zhu XH, Mochel F, Henry PG. Quantification of in vivo ³¹P NMR brain spectra using LCModel. NMR IN BIOMEDICINE 2015; 28:633-41. [PMID: 25871439 PMCID: PMC4438275 DOI: 10.1002/nbm.3291] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2014] [Revised: 03/02/2015] [Accepted: 03/03/2015] [Indexed: 05/05/2023]
Abstract
Quantification of (31)P NMR spectra is commonly performed using line-fitting techniques with prior knowledge. Currently available time- and frequency-domain analysis software includes AMARES (in jMRUI) and CFIT respectively. Another popular frequency-domain approach is LCModel, which has been successfully used to fit both (1)H and (13)C in vivo NMR spectra. To the best of our knowledge LCModel has not been used to fit (31)P spectra. This study demonstrates the feasibility of using LCModel to quantify in vivo (31)P MR spectra, provided that adequate prior knowledge and LCModel control parameters are used. Both single-voxel and MRSI data are presented, and similar results are obtained with LCModel and with AMARES. This provides a new method for automated, operator-independent analysis of (31)P NMR spectra.
Collapse
Affiliation(s)
| | - Tra-My Nguyen
- INSERM UMR S975, Brain and Spine Institute, Hospital La Salpêtrière, Paris, France
| | - Xiao-Hong Zhu
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, USA
| | - Fanny Mochel
- INSERM UMR S975, Brain and Spine Institute, Hospital La Salpêtrière, Paris, France
- University Pierre and Marie Curie, Paris, France
- AP-HP, Department of Genetics, Hospital La Salpêtrière, Paris, France
| | - Pierre-Gilles Henry
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, USA
| |
Collapse
|
5
|
Lee D, Marro K, Mathis M, Shankland E, Hayes C. In vivo absolute quantification for mouse muscle metabolites using an inductively coupled synthetic signal injection method and newly developed (1) H/(31) P dual tuned probe. J Magn Reson Imaging 2014; 39:1039-46. [PMID: 24464912 DOI: 10.1002/jmri.24231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2012] [Accepted: 04/26/2013] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To obtain robust estimates of (31) P metabolite content in mouse skeletal muscles using our recently developed MR absolute quantification method and a custom-built (1) H/(31) P dual tuned radiofrequency (RF) coil optimized for mouse leg. MATERIALS AND METHODS We designed and fabricated a probe consisting of two dual tuned (1) H/(31) P solenoid coils: one leg was inserted to each solenoid. The mouse leg volume coil was incorporated with injector coils for MR absolute quantification. The absolute quantification method uses a synthetic reference signal injection approach and solves several challenges in MR absolute quantification including changes of coil loading and receiver gains. RESULTS The (1) H/(31) P dual tuned probe was composed of two separate solenoid coils, one for each leg, to increase coil filling factors and signal-to-noise ratio. Each solenoid was equipped with a second coil to allow injection of reference signals. (31) P metabolite concentrations determined for normal mice were well within the expected range reported in the literature. CONCLUSION We developed an RF probe and an absolute quantification approach adapted for mouse skeletal muscle.
Collapse
Affiliation(s)
- Donghoon Lee
- Department of Radiology, University of Washington, Seattle, Washington, USA
| | | | | | | | | |
Collapse
|
6
|
Quantification in magnetic resonance spectroscopy based on semi-parametric approaches. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2013; 27:113-30. [DOI: 10.1007/s10334-013-0393-4] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/07/2013] [Revised: 07/08/2013] [Accepted: 07/08/2013] [Indexed: 10/26/2022]
|
7
|
Marro KI, Lee D, Shankland EG, Mathis CM, Hayes CE, Friedman SD, Kushmerick MJ. Quantitative in vivo magnetic resonance spectroscopy using synthetic signal injection. PLoS One 2010; 5:e15166. [PMID: 21203385 PMCID: PMC3010995 DOI: 10.1371/journal.pone.0015166] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2010] [Accepted: 10/27/2010] [Indexed: 01/07/2023] Open
Abstract
Accurate conversion of magnetic resonance spectra to quantitative units of concentration generally requires compensation for differences in coil loading conditions, the gains of the various receiver amplifiers, and rescaling that occurs during post-processing manipulations. This can be efficiently achieved by injecting a precalibrated, artificial reference signal, or pseudo-signal into the data. We have previously demonstrated, using in vitro measurements, that robust pseudo-signal injection can be accomplished using a second coil, called the injector coil, properly designed and oriented so that it couples inductively with the receive coil used to acquire the data. In this work, we acquired nonlocalized phosphorous magnetic resonance spectroscopy measurements from resting human tibialis anterior muscles and used pseudo-signal injection to calculate the Pi, PCr, and ATP concentrations. We compared these results to parallel estimates of concentrations obtained using the more established phantom replacement method. Our results demonstrate that pseudo-signal injection using inductive coupling provides a robust calibration factor that is immune to coil loading conditions and suitable for use in human measurements. Having benefits in terms of ease of use and quantitative accuracy, this method is feasible for clinical use. The protocol we describe could be readily translated for use in patients with mitochondrial disease, where sensitive assessment of metabolite content could improve diagnosis and treatment.
Collapse
Affiliation(s)
- Kenneth I Marro
- Department of Radiology, University of Washington, Seattle, Washington, United States of America.
| | | | | | | | | | | | | |
Collapse
|
8
|
Heinzer-Schweizer S, De Zanche N, Pavan M, Mens G, Sturzenegger U, Henning A, Boesiger P. In-vivo assessment of tissue metabolite levels using 1H MRS and the Electric REference To access In vivo Concentrations (ERETIC) method. NMR IN BIOMEDICINE 2010; 23:406-413. [PMID: 20101606 DOI: 10.1002/nbm.1476] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2008] [Revised: 10/19/2009] [Accepted: 10/19/2009] [Indexed: 05/28/2023]
Abstract
Quantitative values of metabolite concentrations in (1)H magnetic resonance spectroscopy have been obtained using the Electric REference To access In vivo Concentrations (ERETIC) method, whereby a synthetic reference signal is injected during the acquisition of spectra. The method has been improved to enable quantification of metabolite concentrations in vivo. Optical signal transmission was used to eliminate random fluctuations in ERETIC signal coupling to the receiver coil due to changes in position of cables and highly dielectric human tissue. Stability and reliability of the signal were tested in vitro, achieving stability with a mean error of 2.83%. Scaling of the signal in variable loading conditions was demonstrated and in-vivo measurements of brain were acquired on a 3T Philips system using a transmit/receive coil. The quantitative brain water and metabolite concentration values are in good agreement with those in the literature.
Collapse
Affiliation(s)
- S Heinzer-Schweizer
- Institute for Biomedical Engineering, University and ETH Zürich, Zürich, Switzerland.
| | | | | | | | | | | | | |
Collapse
|
9
|
Nirkko AC, Rösler KM, Slotboom J. Muscle Metabolites: Functional MR Spectroscopy during Exercise Imposed by Tetanic Electrical Nerve Stimulation. Radiology 2006; 241:235-42. [PMID: 16928972 DOI: 10.1148/radiol.2411050487] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Permission from the ethics committee and informed consent were obtained. The purpose of this study was to prospectively evaluate a method developed for the noninvasive assessment of muscle metabolites during exercise. Hydrogen 1 magnetic resonance (MR) spectroscopy peaks were measured during tetanic isometric muscle contraction imposed by supramaximal repetitive nerve stimulation. The kinetics of creatine-phosphocreatine and acetylcarnitine signal changes (P < .001) could be assessed continuously before, during, and after exercise. The control peak (trimethylammonium compounds), which served as an internal reference, did not change. This technique-that is, functional MR spectroscopy-opens the possibility for noninvasive diagnostic muscle metabolite testing in a clinical setting.
Collapse
Affiliation(s)
- Arto C Nirkko
- Department of Neurology, University Hospital, Inselspital, CH-3010 Bern, Switzerland.
| | | | | |
Collapse
|
10
|
Jansen JFA, Backes WH, Nicolay K, Kooi ME. 1H MR spectroscopy of the brain: absolute quantification of metabolites. Radiology 2006; 240:318-32. [PMID: 16864664 DOI: 10.1148/radiol.2402050314] [Citation(s) in RCA: 295] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Hydrogen 1 (1H) magnetic resonance (MR) spectroscopy enables noninvasive in vivo quantification of metabolite concentrations in the brain. Currently, metabolite concentrations are most often presented as ratios (eg, relative to creatine) rather than as absolute concentrations. Despite the success of this approach, it has recently been suggested that relative quantification may introduce substantial errors and can lead to misinterpretation of spectral data and to erroneous metabolite values. The present review discusses relevant methods to obtain absolute metabolite concentrations with a clinical MR system by using single-voxel spectroscopy or chemical shift imaging. Important methodological aspects in an absolute quantification strategy are addressed, including radiofrequency coil properties, calibration procedures, spectral fitting methods, cerebrospinal fluid content correction, macromolecule suppression, and spectral editing. Techniques to obtain absolute concentrations are now available and can be successfully applied in clinical practice. Although the present review is focused on 1H MR spectroscopy of the brain, a large part of the methodology described can be applied to other tissues as well.
Collapse
Affiliation(s)
- Jacobus F A Jansen
- Department of Radiology, Maastricht University Hospital, P. Debyelaan 25, 6202 AZ Maastricht, The Netherlands.
| | | | | | | |
Collapse
|
11
|
Jost G, Harting I, Heiland S. Quantitative single-voxel spectroscopy: The reciprocity principle for receive-only head coils. J Magn Reson Imaging 2004; 21:66-71. [PMID: 15611950 DOI: 10.1002/jmri.20236] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
PURPOSE To correct MR spectra for local changes in the coil sensitivity for a widely used coil setup, consisting of a transmitting body coil and a receive-only head coil. MATERIALS AND METHODS The method relies on the reciprocity principle for the body coil and a correction factor for signal amplitudes between body coil and head coil. The correction is based either on the local flip angle dependence of the stimulated echo acquisition mode signal (TFC) or on the automatic RF calibration (RFC). Water phantoms of different volumes were used to simulate variable coil loads, and B1 field inhomogeneities were assessed by varying the voxel position. Furthermore, the correction was tested by longitudinal measurements in one volunteer. RESULTS The correction in vitro yields a reduction of the variation coefficient of the water signal by about 77% (TFC) and 66% (RFC) for different coil loads, as well as 55% (TFC) for variable voxel positions. Slightly lower reductions were assessed for the variation coefficients of the metabolite signals in vivo. CONCLUSION This approach adequately compensates for local changes in coil sensitivity, when acquiring MR spectra with a receive-only head coil.
Collapse
Affiliation(s)
- Gregor Jost
- Division of Neuroradiology, Department of Neurology, University of Heidelberg Medical Center, Heidelberg, Germany.
| | | | | |
Collapse
|
12
|
Pietz J, Rupp A, Ebinger F, Rating D, Mayatepek E, Boesch C, Kreis R. Cerebral energy metabolism in phenylketonuria: findings by quantitative In vivo 31P MR spectroscopy. Pediatr Res 2003; 53:654-62. [PMID: 12612190 DOI: 10.1203/01.pdr.0000055867.83310.9e] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Both severe impairments of brain development in untreated infants and acute reversible neurotoxic effects on brain function are clinical features of phenylketonuria (PKU). For determining whether impairments of cerebral energy metabolism play a role in the pathophysiology of PKU, quantitative in vivo 31P magnetic resonance spectroscopy (MRS) was performed in a supratentorial voxel of 11 adult PKU patients and controls. Peak areas of inorganic phosphate; phosphocreatine; alpha-, beta-, and gamma-ATP; NAD; phosphomonoesters; phosphodiesters; and a broad phospholipid signal were converted to millimolar concentrations. Mg2+, pH, ADP, the phosphorylation potential, and the relative velocity of oxidative metabolism V/Vmax were derived. Clinical evaluation included mutation analysis, neurologic investigation, intelligence testing, magnetic resonance imaging, and concurrent plasma and brain phenylalanine (Phe), the last by 1H-MRS. Phe loading was performed in five patients with an oral dose of 100 mg/kg body wt L-Phe monitored by spectral EEG analysis. Under steady-state conditions, 31P-MRS revealed normal values for ATP, phosphocreatine, NAD, phosphomonoesters, phosphodiesters, Mg2+, and pH in PKU. ADP (+11%) and the phosphorylation potential (+22%) were increased. Peak areas of inorganic phosphate (-22%) and phospholipid (-8%) were decreased. ADP correlated with concurrent plasma (r = 0.65) and brain (r = 0.55) Phe. During the Phe load, blood Phe levels increased steeply. EEG revealed slowing of background activity. The phosphorylation potential decreased, whereas ADP and V/Vmax increased. In vivo 31P-MRS demonstrated subtle abnormalities of cerebral energy metabolism in PKU in steady-state conditions that were accentuated by a Phe load, indicating a link between Phe neurotoxicity and imbalances of cerebral energy metabolism.
Collapse
Affiliation(s)
- Joachim Pietz
- Department of Pediatric Neurology, Division of Metabolic and Endocrine Diseases, University of Heidelberg, Im Neuenheimer Feld 150, Germany.
| | | | | | | | | | | | | |
Collapse
|
13
|
Jensen JE, Drost DJ, Menon RS, Williamson PC. In vivo brain (31)P-MRS: measuring the phospholipid resonances at 4 Tesla from small voxels. NMR IN BIOMEDICINE 2002; 15:338-347. [PMID: 12203225 DOI: 10.1002/nbm.776] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
An optimized phosphorous ((31)P) three-dimensional chemical-shift imaging (3D-CSI) protocol was developed at 4 T to study the phospholipid metabolism from discrete regions in the human brain without the need for (1)H-decoupling or nuclear Overhauser enhancement (NOE). In this study, a spherically bound, weighted average, random point omission 3D-CSI technique was developed and tested, based on methods proposed in the literature. The technique yields a significant (p < 0.001, two-tailed, 5% confidence level) increase in signal-to-noise (SNR) efficiency over conventional 3D-CSI (phantom 32%), without an increase in voxel bleedthrough. An automated time-domain fitting procedure utilizing prior spectral knowledge quantified the individual brain phospholipid metabolites from 15 cm(3) effective (8.0 cm(3) nominal) volumes from the left/right-parieto-occipital cortex and left/right thalamus in 10 normal volunteers. Individual constituents from the phosphomonoester (PME) region; phosphoethanolamine (PEth), phosphocholine (PCh) and the phosphodiester (PDE) region; glycerophosphoethanolamine (GPEth), glycerophosphocholine (GPCh) and membrane phospholipids (MP) were separately quantified to assess the precision of our method at 4 T against previous (1)H-decoupled (31)P-MRS brain studies at lower fields and much larger voxels. Derived concentrations (mM/l tissue) for PEth, PCh, GPEth, GPCh and MP in the left-parieto-occipital cortex were 0.81 +/- 0.21, 0.46 +/- 0.14, 0.74 +/- 0.30, 1.15 +/- 0.43 and 1.54 +/- 0.95 mM, respectively, and 0.94 +/- 0.16, 0.46 +/- 0.17, 0.83 +/- 0.22, 1.14 +/- 0.40 and 1.26 +/- 0.78 mM for the right parieto-occipital cortex. Derived concentrations (mM/l tissue) for PEth, PCh, GPEth, GPCh and MP in the left-thalamus were 0.69 +/- 0.18, 0.42 +/- 0.16, 0.63 +/- 0.20, 1.05 +/- 0.42 and 0.93 +/- 0.56 mM, respectively, and 0.68 +/- 0.24, 0.34 +/- 0.18, 0.60 +/- 0.23, 1.09 +/- 0.36 and 0.74 +/- 0.48 mM for the right-thalamus. This is the first study to our knowledge that has been able to quantify each of these individual phospholipid metabolites from such small voxels in the brain within a clinically reasonable scan time and without (1)H-decoupling or NOE.
Collapse
Affiliation(s)
- J Eric Jensen
- Department of Nuclear Medicine and Magnetic Resonance, St Joseph's Health Center, London, Ontario, Canada.
| | | | | | | |
Collapse
|
14
|
Current awareness in NMR in biomedicine. NMR IN BIOMEDICINE 2002; 15:251-262. [PMID: 11968141 DOI: 10.1002/nbm.748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
|