1
|
Mazier A, Ribes S, Gilles B, Bordas SPA. A rigged model of the breast for preoperative surgical planning. J Biomech 2021; 128:110645. [PMID: 34500364 DOI: 10.1016/j.jbiomech.2021.110645] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 06/23/2021] [Accepted: 07/17/2021] [Indexed: 10/20/2022]
Abstract
In breast surgical practice, drawing is part of the preoperative planning procedure and is essential for a successful operation. In this study, we design a pipeline to assist surgeons with patient-specific breast surgical drawings. We use a deformable torso model containing the surgical patterns to match any breast surface scan. To be compatible with surgical timing, we build an articulated model through a skinning process coupled with shape deformers to enhance a fast registration process. On one hand, the scalable bones of the skinning account for pose and morphological variations of the patients. On the other hand, pre-designed artistic blendshapes create a linear space for guaranteeing anatomical variations. Then, we apply meaningful constraints to the model to find a trade-off between precision and speed. The experiments were conducted on 7 patients, in 2 different poses (prone and supine) with a breast size ranging from 36A and 42C (US/UK bra sizing). The acquisitions were obtained using the depth camera Structure Sensor, and the breast scans were acquired in less than 1 minute. The result is a registration method converging within a few seconds (3 maximum), reaching a Mean Absolute Error of 2.3 mm for mesh registration and 8.0 mm for breast anatomical landmarks. Compared to the existing literature, our model can be personalized and does not require any database. Finally, our registered model can be used to transfer surgical reference patterns onto any patient in any position.
Collapse
Affiliation(s)
- Arnaud Mazier
- Department of Computational Science, Université du Luxembourg, Esch-sur-Alzette, Luxembourg
| | | | | | - Stéphane P A Bordas
- Department of Computational Science, Université du Luxembourg, Esch-sur-Alzette, Luxembourg; China Medical University Hospital, China Medical University, Taichung, Taiwan.
| |
Collapse
|
2
|
Gouveia PF, Costa J, Morgado P, Kates R, Pinto D, Mavioso C, Anacleto J, Martinho M, Lopes DS, Ferreira AR, Vavourakis V, Hadjicharalambous M, Silva MA, Papanikolaou N, Alves C, Cardoso F, Cardoso MJ. Breast cancer surgery with augmented reality. Breast 2021; 56:14-17. [PMID: 33548617 PMCID: PMC7890000 DOI: 10.1016/j.breast.2021.01.004] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Revised: 01/18/2021] [Accepted: 01/20/2021] [Indexed: 11/30/2022] Open
Abstract
Introduction: Innovations in 3D spatial technology and augmented reality imaging driven by digital high-tech industrial science have accelerated experimental advances in breast cancer imaging and the development of medical procedures aimed to reduce invasiveness. Presentation of case: A 57-year-old post-menopausal woman presented with screen-detected left-sided breast cancer. After undergoing all staging and pre-operative studies the patient was proposed for conservative breast surgery with tumor localization. During surgery, an experimental digital and non-invasive intra-operative localization method with augmented reality was compared with the standard pre-operative localization with carbon tattooing (institutional protocol). The breast surgeon wearing an augmented reality headset (Hololens) was able to visualize the tumor location projection inside the patient’s left breast in the usual supine position. Discussion: This work describes, to our knowledge, the first experimental test with a digital non-invasive method for intra-operative breast cancer localization using augmented reality to guide breast conservative surgery. In this case, a successful overlap of the previous standard pre-operative marks with carbon tattooing and tumor visualization inside the patient’s breast with augmented reality was obtained. Conclusion: Breast cancer conservative guided surgery with augmented reality can pave the way for a digital non-invasive method for intra-operative tumor localization.
Collapse
Affiliation(s)
- Pedro F Gouveia
- Breast Unit, Champalimaud Clinical Centre/Champalimaud Foundation,Avenida Brasilia, 1400-038, Lisboa, Portugal; Faculty of Medicine, Lisbon University,Avenida Professor Egas Moniz, 1649-028, Lisboa, Portugal.
| | - Joana Costa
- Breast Unit, Champalimaud Clinical Centre/Champalimaud Foundation,Avenida Brasilia, 1400-038, Lisboa, Portugal.
| | - Pedro Morgado
- AI4medimaging,Rua do Parque Poente, Lote 35, 4705-002, Braga, Portugal.
| | - Ronald Kates
- Breast Unit, Champalimaud Clinical Centre/Champalimaud Foundation,Avenida Brasilia, 1400-038, Lisboa, Portugal.
| | - David Pinto
- Breast Unit, Champalimaud Clinical Centre/Champalimaud Foundation,Avenida Brasilia, 1400-038, Lisboa, Portugal.
| | - Carlos Mavioso
- Breast Unit, Champalimaud Clinical Centre/Champalimaud Foundation,Avenida Brasilia, 1400-038, Lisboa, Portugal.
| | - João Anacleto
- Breast Unit, Champalimaud Clinical Centre/Champalimaud Foundation,Avenida Brasilia, 1400-038, Lisboa, Portugal.
| | - Marta Martinho
- Breast Unit, Champalimaud Clinical Centre/Champalimaud Foundation,Avenida Brasilia, 1400-038, Lisboa, Portugal.
| | - Daniel Simões Lopes
- INESC ID, Instituto Superior Técnico, Lisbon University,Rua Alves Redol 9, 1000-029, Lisboa, Portugal.
| | - Arlindo R Ferreira
- Breast Unit, Champalimaud Clinical Centre/Champalimaud Foundation,Avenida Brasilia, 1400-038, Lisboa, Portugal; Faculty of Medicine, Lisbon University,Avenida Professor Egas Moniz, 1649-028, Lisboa, Portugal.
| | - Vasileios Vavourakis
- Department of Mechanical & Manufacturing Engineering, University of Cyprus,Dept. of Mechanical & Manufacturing Engineering University of Cyprus, Cyprus; Department of Medical Physics & Biomedical Engineering, University College London,Malet Place Engineering Building, University College London, Gower Street, London, WC1E 6BT, United Kingdom.
| | - Myrianthi Hadjicharalambous
- Department of Mechanical & Manufacturing Engineering, University of Cyprus,Dept. of Mechanical & Manufacturing Engineering University of Cyprus, Cyprus.
| | - Marco A Silva
- Microsoft Corporation (Portugal),Rua do Fogo de Santelmo, Lote 2.07.02, Lisboa, Portugal.
| | - Nickolas Papanikolaou
- Breast Unit, Champalimaud Clinical Centre/Champalimaud Foundation,Avenida Brasilia, 1400-038, Lisboa, Portugal.
| | - Celeste Alves
- Breast Unit, Champalimaud Clinical Centre/Champalimaud Foundation,Avenida Brasilia, 1400-038, Lisboa, Portugal.
| | - Fatima Cardoso
- Breast Unit, Champalimaud Clinical Centre/Champalimaud Foundation,Avenida Brasilia, 1400-038, Lisboa, Portugal.
| | - Maria João Cardoso
- Breast Unit, Champalimaud Clinical Centre/Champalimaud Foundation,Avenida Brasilia, 1400-038, Lisboa, Portugal; NOVA Medical School, Campo dos Mártires da Pátria 130, 1169-056, Lisboa, Portugal.
| |
Collapse
|
3
|
Danch-Wierzchowska M, Borys D, Swierniak A. FEM-based MRI deformation algorithm for breast deformation analysis. Biocybern Biomed Eng 2020. [DOI: 10.1016/j.bbe.2020.07.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
4
|
Bessa S, Gouveia PF, Carvalho PH, Rodrigues C, Silva NL, Cardoso F, Cardoso JS, Oliveira HP, Cardoso MJ. 3D digital breast cancer models with multimodal fusion algorithms. Breast 2020; 49:281-290. [PMID: 31986378 PMCID: PMC7375583 DOI: 10.1016/j.breast.2019.12.016] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Revised: 12/23/2019] [Accepted: 12/27/2019] [Indexed: 11/17/2022] Open
Abstract
Breast cancer image fusion consists of registering and visualizing different sets of a patient synchronized torso and radiological images into a 3D model. Breast spatial interpretation and visualization by the treating physician can be augmented with a patient-specific digital breast model that integrates radiological images. But the absence of a ground truth for a good correlation between surface and radiological information has impaired the development of potential clinical applications. A new image acquisition protocol was designed to acquire breast Magnetic Resonance Imaging (MRI) and 3D surface scan data with surface markers on the patient’s breasts and torso. A patient-specific digital breast model integrating the real breast torso and the tumor location was created and validated with a MRI/3D surface scan fusion algorithm in 16 breast cancer patients. This protocol was used to quantify breast shape differences between different modalities, and to measure the target registration error of several variants of the MRI/3D scan fusion algorithm. The fusion of single breasts without the biomechanical model of pose transformation had acceptable registration errors and accurate tumor locations. The performance of the fusion algorithm was not affected by breast volume. Further research and virtual clinical interfaces could lead to fast integration of this fusion technology into clinical practice. MRI/3D surface scan fusion algorithm to create 3D breast cancer models. A replicable clinical validation protocol for MRI/3D surface scan fusion algorithms. Anthropometric study that quantifies breast deformations by area in MRI and 3D scans.
Collapse
Affiliation(s)
- Sílvia Bessa
- INESC TEC, Portugal; University of Porto, Portugal.
| | - Pedro F Gouveia
- Champalimaud Foundation, Portugal; Medical School, Lisbon University, Portugal
| | | | | | - Nuno L Silva
- Champalimaud Foundation, Portugal; Nova Medical School, Portugal
| | | | | | | | - Maria João Cardoso
- INESC TEC, Portugal; Champalimaud Foundation, Portugal; Nova Medical School, Portugal
| |
Collapse
|
5
|
Iterative simulations to estimate the elastic properties from a series of MRI images followed by MRI-US validation. Med Biol Eng Comput 2018; 57:913-924. [PMID: 30483912 DOI: 10.1007/s11517-018-1931-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Accepted: 11/17/2018] [Indexed: 10/27/2022]
Abstract
The modeling of breast deformations is of interest in medical applications such as image-guided biopsy, or image registration for diagnostic purposes. In order to have such information, it is needed to extract the mechanical properties of the tissues. In this work, we propose an iterative technique based on finite element analysis that estimates the elastic modulus of realistic breast phantoms, starting from MRI images acquired in different positions (prone and supine), when deformed only by the gravity force. We validated the method using both a single-modality evaluation in which we simulated the effect of the gravity force to generate four different configurations (prone, supine, lateral, and vertical) and a multi-modality evaluation in which we simulated a series of changes in orientation (prone to supine). Validation is performed, respectively, on surface points and lesions using as ground-truth data from MRI images, and on target lesions inside the breast phantom compared with the actual target segmented from the US image. The use of pre-operative images is limited at the moment to diagnostic purposes. By using our method we can compute patient-specific mechanical properties that allow compensating deformations. Graphical Abstract Workflow of the proposed method and comparative results of the prone-to-supine simulation (red volumes) validated using MRI data (blue volumes).
Collapse
|
6
|
Analytical derivation of elasticity in breast phantoms for deformation tracking. Int J Comput Assist Radiol Surg 2018; 13:1641-1650. [PMID: 29869320 PMCID: PMC6153655 DOI: 10.1007/s11548-018-1803-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Accepted: 05/25/2018] [Indexed: 11/03/2022]
Abstract
PURPOSE Patient-specific biomedical modeling of the breast is of interest for medical applications such as image registration, image guided procedures and the alignment for biopsy or surgery purposes. The computation of elastic properties is essential to simulate deformations in a realistic way. This study presents an innovative analytical method to compute the elastic modulus and evaluate the elasticity of a breast using magnetic resonance (MRI) images of breast phantoms. METHODS An analytical method for elasticity computation was developed and subsequently validated on a series of geometric shapes, and on four physical breast phantoms that are supported by a planar frame. This method can compute the elasticity of a shape directly from a set of MRI scans. For comparison, elasticity values were also computed numerically using two different simulation software packages. RESULTS Application of the different methods on the geometric shapes shows that the analytically derived elongation differs from simulated elongation by less than 9% for cylindrical shapes, and up to 18% for other shapes that are also substantially vertically supported by a planar base. For the four physical breast phantoms, the analytically derived elasticity differs from numeric elasticity by 18% on average, which is in accordance with the difference in elongation estimation for the geometric shapes. The analytic method has shown to be multiple orders of magnitude faster than the numerical methods. CONCLUSION It can be concluded that the analytical elasticity computation method has good potential to supplement or replace numerical elasticity simulations in gravity-induced deformations, for shapes that are substantially supported by a planar base perpendicular to the gravitational field. The error is manageable, while the calculation procedure takes less than one second as opposed to multiple minutes with numerical methods. The results will be used in the MRI and Ultrasound Robotic Assisted Biopsy (MURAB) project.
Collapse
|
7
|
Mertzanidou T, Hipwell JH, Reis S, Hawkes DJ, Ehteshami Bejnordi B, Dalmis M, Vreemann S, Platel B, van der Laak J, Karssemeijer N, Hermsen M, Bult P, Mann R. 3D volume reconstruction from serial breast specimen radiographs for mapping between histology and 3D whole specimen imaging. Med Phys 2017; 44:935-948. [PMID: 28064435 PMCID: PMC6849622 DOI: 10.1002/mp.12077] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2016] [Revised: 11/10/2016] [Accepted: 12/18/2016] [Indexed: 11/11/2022] Open
Abstract
PURPOSE In breast imaging, radiological in vivo images, such as x-ray mammography and magnetic resonance imaging (MRI), are used for tumor detection, diagnosis, and size determination. After excision, the specimen is typically sliced into slabs and a small subset is sampled. Histopathological imaging of the stained samples is used as the gold standard for characterization of the tumor microenvironment. A 3D volume reconstruction of the whole specimen from the 2D slabs could facilitate bridging the gap between histology and in vivo radiological imaging. This task is challenging, however, due to the large deformation that the breast tissue undergoes after surgery and the significant undersampling of the specimen obtained in histology. In this work, we present a method to reconstruct a coherent 3D volume from 2D digital radiographs of the specimen slabs. METHODS To reconstruct a 3D breast specimen volume, we propose the use of multiple target neighboring slices, when deforming each 2D slab radiograph in the volume, rather than performing pairwise registrations. The algorithm combines neighborhood slice information with free-form deformations, which enables a flexible, nonlinear deformation to be computed subject to the constraint that a coherent 3D volume is obtained. The neighborhood information provides adequate constraints, without the need for any additional regularization terms. RESULTS The volume reconstruction algorithm is validated on clinical mastectomy samples using a quantitative assessment of the volume reconstruction smoothness and a comparison with a whole specimen 3D image acquired for validation before slicing. Additionally, a target registration error of 5 mm (comparable to the specimen slab thickness of 4 mm) was obtained for five cases. The error was computed using manual annotations from four observers as gold standard, with interobserver variability of 3.4 mm. Finally, we illustrate how the reconstructed volumes can be used to map histology images to a 3D specimen image of the whole sample (either MRI or CT). CONCLUSIONS Qualitative and quantitative assessment has illustrated the benefit of using our proposed methodology to reconstruct a coherent specimen volume from serial slab radiographs. To our knowledge, this is the first method that has been applied to clinical breast cases, with the goal of reconstructing a whole specimen sample. The algorithm can be used as part of the pipeline of mapping histology images to ex vivo and ultimately in vivo radiological images of the breast.
Collapse
Affiliation(s)
- Thomy Mertzanidou
- Centre for Medical Image ComputingUniversity College LondonWC1E 6BTLondonUK
| | - John H. Hipwell
- Centre for Medical Image ComputingUniversity College LondonWC1E 6BTLondonUK
| | - Sara Reis
- Centre for Medical Image ComputingUniversity College LondonWC1E 6BTLondonUK
| | - David J. Hawkes
- Centre for Medical Image ComputingUniversity College LondonWC1E 6BTLondonUK
| | | | - Mehmet Dalmis
- Diagnostic Image Analysis GroupRadboud University Medical Center6500 HBNijmegenThe Netherlands
| | - Suzan Vreemann
- Diagnostic Image Analysis GroupRadboud University Medical Center6500 HBNijmegenThe Netherlands
| | - Bram Platel
- Diagnostic Image Analysis GroupRadboud University Medical Center6500 HBNijmegenThe Netherlands
| | - Jeroen van der Laak
- Diagnostic Image Analysis GroupRadboud University Medical Center6500 HBNijmegenThe Netherlands
| | - Nico Karssemeijer
- Diagnostic Image Analysis GroupRadboud University Medical Center6500 HBNijmegenThe Netherlands
| | - Meyke Hermsen
- Department of PathologyRadboud University Medical Center6500 HBNijmegenThe Netherlands
| | - Peter Bult
- Department of PathologyRadboud University Medical Center6500 HBNijmegenThe Netherlands
| | - Ritse Mann
- Department of RadiologyRadboud University Medical Center6500 HBNijmegenThe Netherlands
| |
Collapse
|
8
|
Hipwell JH, Vavourakis V, Han L, Mertzanidou T, Eiben B, Hawkes DJ. A review of biomechanically informed breast image registration. Phys Med Biol 2016; 61:R1-31. [PMID: 26733349 DOI: 10.1088/0031-9155/61/2/r1] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Breast radiology encompasses the full range of imaging modalities from routine imaging via x-ray mammography, magnetic resonance imaging and ultrasound (both two- and three-dimensional), to more recent technologies such as digital breast tomosynthesis, and dedicated breast imaging systems for positron emission mammography and ultrasound tomography. In addition new and experimental modalities, such as Photoacoustics, Near Infrared Spectroscopy and Electrical Impedance Tomography etc, are emerging. The breast is a highly deformable structure however, and this greatly complicates visual comparison of imaging modalities for the purposes of breast screening, cancer diagnosis (including image guided biopsy), tumour staging, treatment monitoring, surgical planning and simulation of the effects of surgery and wound healing etc. Due primarily to the challenges posed by these gross, non-rigid deformations, development of automated methods which enable registration, and hence fusion, of information within and across breast imaging modalities, and between the images and the physical space of the breast during interventions, remains an active research field which has yet to translate suitable methods into clinical practice. This review describes current research in the field of breast biomechanical modelling and identifies relevant publications where the resulting models have been incorporated into breast image registration and simulation algorithms. Despite these developments there remain a number of issues that limit clinical application of biomechanical modelling. These include the accuracy of constitutive modelling, implementation of representative boundary conditions, failure to meet clinically acceptable levels of computational cost, challenges associated with automating patient-specific model generation (i.e. robust image segmentation and mesh generation) and the complexity of applying biomechanical modelling methods in routine clinical practice.
Collapse
Affiliation(s)
- John H Hipwell
- Centre for Medical Image Computing, Malet Place Engineering Building, University College London, Gower Street, London WC1E 6BT, UK
| | | | | | | | | | | |
Collapse
|
9
|
Han L, Hipwell JH, Eiben B, Barratt D, Modat M, Ourselin S, Hawkes DJ. A nonlinear biomechanical model based registration method for aligning prone and supine MR breast images. IEEE TRANSACTIONS ON MEDICAL IMAGING 2014; 33:682-694. [PMID: 24595342 DOI: 10.1109/tmi.2013.2294539] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Preoperative diagnostic magnetic resonance (MR) breast images can provide good contrast between different tissues and 3-D information about suspicious tissues. Aligning preoperative diagnostic MR images with a patient in the theatre during breast conserving surgery could assist surgeons in achieving the complete excision of cancer with sufficient margins. Typically, preoperative diagnostic MR breast images of a patient are obtained in the prone position, while surgery is performed in the supine position. The significant shape change of breasts between these two positions due to gravity loading, external forces and related constraints makes the alignment task extremely difficult. Our previous studies have shown that either nonrigid intensity-based image registration or biomechanical modelling alone are limited in their ability to capture such a large deformation. To tackle this problem, we proposed in this paper a nonlinear biomechanical model-based image registration method with a simultaneous optimization procedure for both the material parameters of breast tissues and the direction of the gravitational force. First, finite element (FE) based biomechanical modelling is used to estimate a physically plausible deformation of the pectoral muscle and the major deformation of breast tissues due to gravity loading. Then, nonrigid intensity-based image registration is employed to recover the remaining deformation that FE analyses do not capture due to the simplifications and approximations of biomechanical models and the uncertainties of external forces and constraints. We assess the registration performance of the proposed method using the target registration error of skin fiducial markers and the Dice similarity coefficient (DSC) of fibroglandular tissues. The registration results on prone and supine MR image pairs are compared with those from two alternative nonrigid registration methods for five breasts. Overall, the proposed algorithm achieved the best registration performance on fiducial markers (target registration error, 8.44 ±5.5 mm for 45 fiducial markers) and higher overlap rates on segmentation propagation of fibroglandular tissues (DSC value > 82%).
Collapse
|
10
|
Sotiras A, Davatzikos C, Paragios N. Deformable medical image registration: a survey. IEEE TRANSACTIONS ON MEDICAL IMAGING 2013; 32:1153-90. [PMID: 23739795 PMCID: PMC3745275 DOI: 10.1109/tmi.2013.2265603] [Citation(s) in RCA: 580] [Impact Index Per Article: 52.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Deformable image registration is a fundamental task in medical image processing. Among its most important applications, one may cite: 1) multi-modality fusion, where information acquired by different imaging devices or protocols is fused to facilitate diagnosis and treatment planning; 2) longitudinal studies, where temporal structural or anatomical changes are investigated; and 3) population modeling and statistical atlases used to study normal anatomical variability. In this paper, we attempt to give an overview of deformable registration methods, putting emphasis on the most recent advances in the domain. Additional emphasis has been given to techniques applied to medical images. In order to study image registration methods in depth, their main components are identified and studied independently. The most recent techniques are presented in a systematic fashion. The contribution of this paper is to provide an extensive account of registration techniques in a systematic manner.
Collapse
Affiliation(s)
- Aristeidis Sotiras
- Section of Biomedical Image Analysis, Center for Biomedical Image Computing and Analytics, Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104 USA
| | - Christos Davatzikos
- Section of Biomedical Image Analysis, Center for Biomedical Image Computing and Analytics, Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104 USA
| | - Nikos Paragios
- Center for Visual Computing, Department of Applied Mathematics, Ecole Centrale de Paris, Chatenay-Malabry, 92 295 FRANCE, the Equipe Galen, INRIA Saclay - Ile-de-France, Orsay, 91893 FRANCE and the Universite Paris-Est, LIGM (UMR CNRS), Center for Visual Computing, Ecole des Ponts ParisTech, Champs-sur-Marne, 77455 FRANCE
| |
Collapse
|
11
|
Bock A, Sunden E, Liu B, Wunsche B, Ropinski T. Coherency-Based Curve Compression for High-Order Finite Element Model Visualization. IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS 2012; 18:2315-2324. [PMID: 26357139 DOI: 10.1109/tvcg.2012.206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Finite element (FE) models are frequently used in engineering and life sciences within time-consuming simulations. In contrast with the regular grid structure facilitated by volumetric data sets, as used in medicine or geosciences, FE models are defined over a non-uniform grid. Elements can have curved faces and their interior can be defined through high-order basis functions, which pose additional challenges when visualizing these models. During ray-casting, the uniformly distributed sample points along each viewing ray must be transformed into the material space defined within each element. The computational complexity of this transformation makes a straightforward approach inadequate for interactive data exploration. In this paper, we introduce a novel coherency-based method which supports the interactive exploration of FE models by decoupling the expensive world-to-material space transformation from the rendering stage, thereby allowing it to be performed within a precomputation stage. Therefore, our approach computes view-independent proxy rays in material space, which are clustered to facilitate data reduction. During rendering, these proxy rays are accessed, and it becomes possible to visually analyze high-order FE models at interactive frame rates, even when they are time-varying or consist of multiple modalities. Within this paper, we provide the necessary background about the FE data, describe our decoupling method, and introduce our interactive rendering algorithm. Furthermore, we provide visual results and analyze the error introduced by the presented approach.
Collapse
Affiliation(s)
- A Bock
- Scientific Visualization Group, Link¨oping University, Sweden.
| | | | | | | | | |
Collapse
|
12
|
Juneja P, Harris EJ, Kirby AM, Evans PM. Adaptive Breast Radiation Therapy Using Modeling of Tissue Mechanics: A Breast Tissue Segmentation Study. Int J Radiat Oncol Biol Phys 2012; 84:e419-25. [DOI: 10.1016/j.ijrobp.2012.05.014] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2011] [Revised: 04/26/2012] [Accepted: 05/06/2012] [Indexed: 10/27/2022]
|
13
|
Patient-Specific Modeling of Breast Biomechanics with Applications to Breast Cancer Detection and Treatment. PATIENT-SPECIFIC MODELING IN TOMORROW'S MEDICINE 2011. [DOI: 10.1007/8415_2011_92] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|