• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4615257)   Today's Articles (1281)   Subscriber (49393)
For: Geddes LA, Moore AG. The efficient detection of Korotkoff sounds. Med Biol Eng 1968;6:603-9. [PMID: 5713299 DOI: 10.1007/bf02474723] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Number Cited by Other Article(s)
1
Yoshida K, Sawano R, Okamoto M, Murao K, Tsuchida S, Terada T. Physical Noninvasive Attacks on Photoplethysmogram by Computer Controlled Blood Pressure Cuff. SENSORS (BASEL, SWITZERLAND) 2023;23:9764. [PMID: 38139610 PMCID: PMC10747835 DOI: 10.3390/s23249764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 11/29/2023] [Accepted: 12/07/2023] [Indexed: 12/24/2023]
2
Centracchio J, De Caro D, Bifulco P, Andreozzi E. B3X: a novel efficient algorithm for accurate automated auscultatory blood pressure estimation. Physiol Meas 2023;44:095007. [PMID: 37659397 DOI: 10.1088/1361-6579/acf643] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Accepted: 09/01/2023] [Indexed: 09/04/2023]
3
Lin W, Jia S, Chen Y, Shi H, Zhao J, Li Z, Wu Y, Jiang H, Zhang Q, Wang W, Chen Y, Feng C, Xia S. Korotkoff sounds dynamically reflect changes in cardiac function based on deep learning methods. Front Cardiovasc Med 2022;9:940615. [PMID: 36093170 PMCID: PMC9458936 DOI: 10.3389/fcvm.2022.940615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Accepted: 07/18/2022] [Indexed: 11/24/2022]  Open
4
Deep learning-based robust automatic non-invasive measurement of blood pressure using Korotkoff sounds. Sci Rep 2021;11:23365. [PMID: 34862399 PMCID: PMC8642395 DOI: 10.1038/s41598-021-02513-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Accepted: 11/17/2021] [Indexed: 11/09/2022]  Open
5
Pan F, He P, Liu C, Li T, Murray A, Zheng D. Variation of the Korotkoff Stethoscope Sounds During Blood Pressure Measurement: Analysis Using a Convolutional Neural Network. IEEE J Biomed Health Inform 2018;21:1593-1598. [PMID: 29136608 DOI: 10.1109/jbhi.2017.2703115] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
6
Babbs CF. The origin of Korotkoff sounds and the accuracy of auscultatory blood pressure measurements. ACTA ACUST UNITED AC 2015;9:935-50.e3. [DOI: 10.1016/j.jash.2015.09.011] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2015] [Revised: 08/11/2015] [Accepted: 09/10/2015] [Indexed: 10/23/2022]
7
Davis GJ, Geddes LA. Auscultatory mean blood pressure. J Clin Monit Comput 1990;6:261-5. [PMID: 2230854 DOI: 10.1007/bf02842484] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
8
Geddes LA, Voelz M, Combs C, Reiner D, Babbs CF. Characterization of the oscillometric method for measuring indirect blood pressure. Ann Biomed Eng 1982;10:271-80. [PMID: 7171156 DOI: 10.1007/bf02367308] [Citation(s) in RCA: 142] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
9
Ellis PM. The indirect measurement of arterial blood pressure in the horse. Equine Vet J 1975;7:22-6. [PMID: 1116492 DOI: 10.1111/j.2042-3306.1975.tb03224.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
10
Golden DP, Wolthuis RA, Hoffler GW, Gowen RJ. Development of a Korotkov sound processor for automatic identification of auscultatory events. I. Specification of preprocessing bandpass filters. IEEE Trans Biomed Eng 1974;21:114-8. [PMID: 4818796 DOI: 10.1109/tbme.1974.324296] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA