1
|
Hasegawa IG, Sakka B, Duong AM, Ding L, Wong MD, Gary JL, Patterson JT. Anterior internal versus external fixation of unstable pelvis fractures was not associated with discharge destination, critical care, length of stay, or hospital charges. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2024; 34:2773-2778. [PMID: 38771369 PMCID: PMC11291563 DOI: 10.1007/s00590-024-03985-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Accepted: 04/29/2024] [Indexed: 05/22/2024]
Abstract
PURPOSE Determine if anterior internal versus supra-acetabular external fixation of unstable pelvic fractures is associated with care needs or discharge. METHODS A retrospective cohort study was performed at two tertiary trauma referral centers. Adults with unstable pelvis fractures (AO/OTA 61B/61C) who received operative fixation of the anterior and posterior pelvic ring by two orthopedic trauma surgeons from October 2020 to November 2022 were included. The primary outcome was discharge destination. Secondary outcomes included intensive care unit (ICU) or ventilator days, length of stay, and hospital charges. RESULTS Eighty-three eligible patients were 38.6% female, with a mean age of 47.2 ± 20.3 years and BMI 28.1 ± 6.4 kg/m2. Fifty-nine patients (71.1%) received anterior pelvis internal fixation and 24 (28.9%) received external fixation. External fixation was associated with weight-bearing restrictions (91.7% versus 49.2%, p = 0.01). No differences in demographic, functional status, insurance type, fracture classification, or injury severity measures were observed by treatment. Internal versus external anterior pelvic fixation was not associated with discharge to home (49.2% versus 29.2%, p = 0.10), median ICU days (3.0 [interquartile range (IQR) 7.8 versus 5.5 [IQR 4.3], p = 0.14, ventilator days (0 [IQR 6.0] versus 0 [IQR 2.8], p = 0.51), length of stay (13.0 [IQR 13.0] versus 17.5 (IQR 20.5), p = 0.38), or total hospital charges (US dollars 180,311 [IQR 219,061.75] versus 243,622 [IQR 187,111], p = 0.14). CONCLUSIONS Anterior internal versus supra-acetabular external fixation of unstable pelvis fractures was not significantly associated with discharge destination, critical care, hospital length of stay, or hospital charges. This sample may be underpowered to detect differences between groups. LEVEL OF EVIDENCE Therapeutic Level IV.
Collapse
Affiliation(s)
- Ian G Hasegawa
- Dpeartment of Orthopaedic Surgery, Queens Medical Center, Honolulu, Hawaii, US
| | - Brandan Sakka
- Department of Orthopaedic Surgery, Keck School of Medicine of University of Southern California, 1520 San Pablo Street, Suite 2000, Los Angeles, CA, 90033-5322, US
| | - Andrew M Duong
- Department of Orthopaedic Surgery, Keck School of Medicine of University of Southern California, 1520 San Pablo Street, Suite 2000, Los Angeles, CA, 90033-5322, US
| | - Li Ding
- Department of Population and Public Health Sciences, Keck School of Medicine of University of Southern California, Los Angeles, CA, US
| | - Monica D Wong
- Department of Surgery, Keck School of Medicine of University of Southern California, Los Angeles, CA, US
| | - Joshua L Gary
- Department of Orthopaedic Surgery, Keck School of Medicine of University of Southern California, 1520 San Pablo Street, Suite 2000, Los Angeles, CA, 90033-5322, US
| | - Joseph T Patterson
- Department of Orthopaedic Surgery, Keck School of Medicine of University of Southern California, 1520 San Pablo Street, Suite 2000, Los Angeles, CA, 90033-5322, US.
| |
Collapse
|
2
|
Patterson JT, Brown M, Hasegawa IG, Becerra JA, Duong AM, Reddy A, Gary JL. Incidence of Suboptimal Fluoroscopic Outlet Imaging of the Sacrum and Pelvic Retroversion Necessary for Optimal Views. J Orthop Trauma 2024; 38:299-305. [PMID: 38470146 DOI: 10.1097/bot.0000000000002795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Accepted: 03/04/2024] [Indexed: 03/13/2024]
Abstract
OBJECTIVES To estimate the prevalence of suboptimal fluoroscopy of sacral outlet images due to anatomic and equipment dimensions. Pelvic retroversion is hypothesized to mitigate this issue. METHODS DESIGN In silico simulations using retrospectively collected computed tomography (CT) data from human patients. SETTING Level I trauma center. PATIENT SELECTION CRITERIA Adults with OTA/AO 61 pelvic ring disruptions treated with posterior pelvic fixation between July and December 2021. OUTCOME MEASURES AND COMPARISONS C-arm tilt angles required to obtain 3 optimal fluoroscopic sacral outlet images, defined as vectors from pubic symphysis to S2 and parallel to the first and second sacral neural foramina, were calculated from sagittal CT images. A suboptimal view was defined as collision of the C-arm radiation source or image intensifier with the patient/operating table at the required tilt angle simulated using the dimensions of 5 commercial C-arm models and trigonometric calculations. Incidence of suboptimal outlet views and pelvic retroversion necessary to obtain optimal views without collision, which may be obtained by placement of a sacral bump, was determined for each view for all patients and C-arm models. RESULTS CT data from 72 adults were used. Collision between patient and C-arm would occur at the optimal tilt angle for 17% of simulations and at least 1 view in 68% of patients. Greater body mass index was associated with greater odds of suboptimal imaging (standard outlet: odds ratio [OR] 0.84, confidence interval [CI] 0.79-0.89, P < 0.001; S1: OR 0.91, CI 0.87-0.97, P = 0.002; S2: OR 0.85, CI 0.80-0.91, P < 0.001). S1 anterior sacral slope was associated with suboptimal S1 outlet views (OR 1.12, Cl 1.07-1.17, P < 0.001). S2 anterior sacral slope was associated with suboptimal standard outlet (OR 1.07, Cl 1.02-1.13, P = 0.004) and S2 outlet (OR 1.16, Cl 1.09-1.23, P < 0.001) views. Retroversion of the pelvis 15-20 degrees made optimal outlet views possible without collision in 95%-99% of all simulations, respectively. CONCLUSIONS Suboptimal outlet imaging of the sacrum is associated with greater body mass index and sacral slope at S1 and S2. Retroversion of the pelvis by 15-20 degrees with a bump under the distal sacrum may offer a low-tech solution to ensure optimal fluoroscopic imaging for percutaneous fixation of the posterior pelvic ring. LEVEL OF EVIDENCE Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Joseph T Patterson
- Department of Orthopaedic Surgery, Keck School of Medicine of University of Southern California, Los Angeles, CA; and
| | - Michael Brown
- Department of Orthopaedic Surgery, Keck School of Medicine of University of Southern California, Los Angeles, CA; and
| | - Ian G Hasegawa
- Department of Orthopaedic Surgery and Rehabilitation, Queen's Medical Center, Honolulu, HI
| | - Jacob A Becerra
- Department of Orthopaedic Surgery, Keck School of Medicine of University of Southern California, Los Angeles, CA; and
| | - Andrew M Duong
- Department of Orthopaedic Surgery, Keck School of Medicine of University of Southern California, Los Angeles, CA; and
| | - Akhil Reddy
- Department of Orthopaedic Surgery, Keck School of Medicine of University of Southern California, Los Angeles, CA; and
| | - Joshua L Gary
- Department of Orthopaedic Surgery, Keck School of Medicine of University of Southern California, Los Angeles, CA; and
| |
Collapse
|
3
|
Klingebiel FKL, Hasegawa M, Parry J, Balogh ZJ, Sen RK, Kalbas Y, Teuben M, Halvachizadeh S, Pape HC, Pfeifer R. Standard practice in the treatment of unstable pelvic ring injuries: an international survey. INTERNATIONAL ORTHOPAEDICS 2023; 47:2301-2318. [PMID: 37328569 PMCID: PMC10439026 DOI: 10.1007/s00264-023-05859-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Accepted: 05/27/2023] [Indexed: 06/18/2023]
Abstract
PURPOSE Unstable pelvic ring injury can result in a life-threatening situation and lead to long-term disability. Established classification systems, recently emerged resuscitative and treatment options as well as techniques, have facilitated expansion in how these injuries can be studied and managed. This study aims to access practice variation in the management of unstable pelvic injuries around the globe. METHODS A standardized questionnaire including 15 questions was developed by experts from the SICOT trauma committee (Société Internationale de Chirurgie Orthopédique et de Traumatologie) and then distributed among members. The survey was conducted online for one month in 2022 with 358 trauma surgeons, encompassing responses from 80 countries (experience > 5 years = 79%). Topics in the questionnaire included surgical and interventional treatment strategies, classification, staging/reconstruction procedures, and preoperative imaging. Answer options for treatment strategies were ranked on a 4-point rating scale with following options: (1) always (A), (2) often (O), (3) seldom (S), and (4) never (N). Stratification was performed according to geographic regions (continents). RESULTS The Young and Burgess (52%) and Tile/AO (47%) classification systems were commonly used. Preoperative three-dimensional (3D) computed tomography (CT) scans were utilized by 93% of respondents. Rescue screws (RS), C-clamps (CC), angioembolization (AE), and pelvic packing (PP) were observed to be rarely implemented in practice (A + O: RS = 24%, CC = 25%, AE = 21%, PP = 25%). External fixation was the most common method temporized fixation (A + O = 71%). Percutaneous screw fixation was the most common definitive fixation technique (A + O = 57%). In contrast, 3D navigation techniques were rarely utilized (A + O = 15%). Most standards in treatment of unstable pelvic ring injuries are implemented equally across the globe. The greatest differences were observed in augmented techniques to bleeding control, such as angioembolization and REBOA, more commonly used in Europe (both), North America (both), and Oceania (only angioembolization). CONCLUSION The Young-Burgess and Tile/AO classifications are used approximately equally across the world. Initial non-invasive stabilization with binders and temporary external fixation are commonly utilized, while specific haemorrhage control techniques such as pelvic packing and angioembolization are rarely and REBOA almost never considered. The substantial regional differences' impact on outcomes needs to be further explored.
Collapse
Affiliation(s)
- Felix Karl-Ludwig Klingebiel
- Department of Traumatology, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland
- Department of Surgical Research, Harald Tscherne Laboratory for Orthopaedic and Trauma Research, Zurich University Hospital, Zurich, Switzerland
| | - Morgan Hasegawa
- Division of Orthopaedic Surgery, John A. Burns School of Medicine, University of Hawai’i, Honolulu, HI USA
| | - Joshua Parry
- Department of Orthopaedics, Denver Health Medical Center, University of Colorado School of Medicine, Denver, CO USA
| | - Zsolt J. Balogh
- Department of Traumatology, John Hunter Hospital, Hunter Medical Research Institute and University of Newcastle, Newcastle, NSW Australia
| | | | - Yannik Kalbas
- Department of Traumatology, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland
- Department of Surgical Research, Harald Tscherne Laboratory for Orthopaedic and Trauma Research, Zurich University Hospital, Zurich, Switzerland
| | - Michel Teuben
- Department of Traumatology, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland
- Department of Surgical Research, Harald Tscherne Laboratory for Orthopaedic and Trauma Research, Zurich University Hospital, Zurich, Switzerland
| | - Sascha Halvachizadeh
- Department of Traumatology, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland
- Department of Surgical Research, Harald Tscherne Laboratory for Orthopaedic and Trauma Research, Zurich University Hospital, Zurich, Switzerland
| | - Hans-Christoph Pape
- Department of Traumatology, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland
- Department of Surgical Research, Harald Tscherne Laboratory for Orthopaedic and Trauma Research, Zurich University Hospital, Zurich, Switzerland
| | - Roman Pfeifer
- Department of Traumatology, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland
- Department of Surgical Research, Harald Tscherne Laboratory for Orthopaedic and Trauma Research, Zurich University Hospital, Zurich, Switzerland
| |
Collapse
|
4
|
Lodde MF, Fischer TM, Riesenbeck O, Roßlenbroich S, Katthagen JC, Rometsch D, Günes D, Schneider M, Raschke MJ, Liljenqvist U. Analysis of the Spinopelvic Parameters in Patients with Fragility Fractures of the Pelvis. J Clin Med 2023; 12:4445. [PMID: 37445480 DOI: 10.3390/jcm12134445] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 06/28/2023] [Accepted: 06/29/2023] [Indexed: 07/15/2023] Open
Abstract
BACKGROUND We investigated the spinopelvic parameters of lumbar lordosis (LL), pelvic incidence (PI), pelvic tilt (PT) and sacral slope (SS) in patients with fragility fractures of the pelvis (FFPs). We hypothesized that these parameters differ from asymptomatic patients. METHODS All patients treated for FFPs in a center of maximal care of the German Spine Society (DWG) between 2017 and 2021 were included. The inclusion criteria were age ≥ 60 years and the availability of a standing lateral radiograph of the spine and pelvis in which the spine from T12 to S1 and both femoral heads were visible. The baseline characteristics and study parameters were calculated and compared with databases of asymptomatic patients. The two-sample t-Test was performed with p < 0.05. RESULTS The study population (n = 57) consisted of 49 female patients. The mean age was 81.0 years. The mean LL was 47.9°, the mean PT was 29.4°, the mean SS was 34.2° and the mean PI was 64.4°. The mean value of LLI was 0.7. LL, LLI and SS were significantly reduced, and PI and PT were significantly increased compared to asymptomatic patients. CONCLUSIONS The spinopelvic parameters in patients with FFPs differ significantly from asymptomatic patients. In patients with FFPs, LL, LLI and SS are significantly reduced, and PI and PT are significantly increased. The sagittal spinopelvic balance is abnormal in patients with FFPs.
Collapse
Affiliation(s)
- Moritz F Lodde
- Department for Trauma Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus 1, Building W1, Waldeyerstraße 1, 48149 Münster, Germany
| | - Thies M Fischer
- Department for Spine Surgery and Scoliosis, St. Franziskus-Hospital GmbH Münster, Hohenzollernring 70, 48145 Münster, Germany
| | - Oliver Riesenbeck
- Department for Trauma Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus 1, Building W1, Waldeyerstraße 1, 48149 Münster, Germany
| | - Steffen Roßlenbroich
- Department for Trauma Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus 1, Building W1, Waldeyerstraße 1, 48149 Münster, Germany
| | - J Christoph Katthagen
- Department for Trauma Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus 1, Building W1, Waldeyerstraße 1, 48149 Münster, Germany
| | - Daria Rometsch
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Münster, Kardinal-von-Galen-Ring 10, 48149 Münster, Germany
| | - Dennis Günes
- Department for Spine Surgery and Scoliosis, St. Franziskus-Hospital GmbH Münster, Hohenzollernring 70, 48145 Münster, Germany
| | - Marc Schneider
- Department for Spine Surgery and Scoliosis, St. Franziskus-Hospital GmbH Münster, Hohenzollernring 70, 48145 Münster, Germany
| | - Michael J Raschke
- Department for Trauma Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus 1, Building W1, Waldeyerstraße 1, 48149 Münster, Germany
| | - Ulf Liljenqvist
- Department for Spine Surgery and Scoliosis, St. Franziskus-Hospital GmbH Münster, Hohenzollernring 70, 48145 Münster, Germany
| |
Collapse
|
5
|
Baumann F, Pagano S, Alt V, Freigang V. Bony Sacral Volume after Sacro-Iliac Screw Fixation of Pelvic Fractures Is Dependent on Reduction of the Anterior Pelvic Ring. J Clin Med 2023; 12:4169. [PMID: 37373862 DOI: 10.3390/jcm12124169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 06/13/2023] [Accepted: 06/15/2023] [Indexed: 06/29/2023] Open
Abstract
Pelvic ring injuries are uncommon but serious injuries. Percutaneous sacro-iliac screw fixation (SSF) is the standard treatment for posterior stabilization of pelvic fractures. Compression forces of the SSF might cause deformity of the sacrum and the pelvic ring. The aim of this radio-volumetric study is to evaluate the morphometry of the sacrum and pelvic ring in SSF for posterior pelvic fractures. (1) Methods: We conducted a radio-volumetric study measuring the bony sacral volume before and after SSF for a pelvic fracture based on a three-dimensional reconstruction of the pre- and postoperative computed tomography scan of 19 patients with a C-type pelvic fracture. In addition to the bony sacral volume, we assessed the pelvic deformity and the load bearing axis. We compared the results of patients without anterior stabilization (Group A) to patients who had additional ORIF of the anterior pelvic ring. (2) Results: Median age of the patients was 41.2 years (±17.8). All patients received percutaneous SSF with partially threaded 7.3 mm screws. The sacral volume decreased from 202.9 to 194.3 cm3 in group A (non-operative treatment anterior, n = 10) and an increase of sacral volume from 229.8 to 250.4 cm3 in group B (anterior ORIF; n = 9). Evaluation of the pelvic deformity also reflected this trend by a decrease of the ipsilateral load-bearing angle in group A (37.0° to 36.4°) and an increase of this angle in group B (36.3 to 39.9°). (3) Conclusions: Bony sacral volume and pelvic deformity after sacro-iliac screw fixation in pelvic fractures depend on treatment of the anterior pelvic ring. Reduction and fixation of the anterior fracture shows an increase of the bony sacral volume and the load bearing angle leading to a closer to normal reconstruction of the pelvic anatomy.
Collapse
Affiliation(s)
- Florian Baumann
- Department of Trauma Surgery, University Medical Centre Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany
| | - Stefano Pagano
- Department of Trauma Surgery, University Medical Centre Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany
| | - Volker Alt
- Department of Trauma Surgery, University Medical Centre Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany
| | - Viola Freigang
- Department of Trauma Surgery, University Medical Centre Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany
| |
Collapse
|
6
|
Lodde MF, Raschke MJ, Riesenbeck O. FFP: Indication for minimally invasive navigation technique. Trauma Case Rep 2023; 45:100829. [PMID: 37091838 PMCID: PMC10113893 DOI: 10.1016/j.tcr.2023.100829] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 02/20/2023] [Accepted: 04/02/2023] [Indexed: 04/25/2023] Open
Abstract
An 85-year-old female patient was transferred to our clinic for surgical treatment of a complex FFP IIc. She had suffered a ground level fall 10 days ago and was still living independently. The patient was initially treated conservatively with pain medication and immobilization in an outward hospital. Due to the clinical symptoms and complex fracture pattern a physiotherapeutic assisted mobilization was not possible. The clinical examination revealed severe bilateral pain at the anterior and posterior pelvic ring. We performed a minimally invasive and an image-guided surgical stabilization. After surgical treatment the patient was mobilized with crutches for short distances. On the third day after surgical intervention the patient was discharged from our hospital into rehabilitation. This case shows the successful use of minimally invasive and modern navigation technique for treatment of a complex FFP.
Collapse
|
7
|
Barger K, Robinson M. An evaluation of the inlet obturator oblique view for sacroiliac and transsacral screw placement. Arch Orthop Trauma Surg 2023; 143:1869-1875. [PMID: 35199213 DOI: 10.1007/s00402-022-04370-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Accepted: 01/25/2022] [Indexed: 11/02/2022]
Abstract
INTRODUCTION Between 2005 and 2017, the number of closed reduction and internal fixation of pelvic ring injuries increased by 1116%. Percutaneous fixation is currently the only minimally invasive technique that can stabilize the posterior elements of the pelvis. The purpose of this study was to investigate the utility of the inlet obturator oblique view (IOO) with the hypothesis that the IOO view will improve the accuracy of sacroiliac and transsacral screw placement in the S1 or S2 body and improve the accuracy of assessing whether the implant is fully seated against the outer cortex of the ilium. MATERIALS AND METHODS Ten male pelvic training models were used. Thirty-six screw configurations were inserted by a fellowship trained orthopedic trauma surgeon in appropriately and inappropriately placed sacroiliac and transsacral screw configurations. These configurations were imaged using fluoroscopy in different planes and saved for survey. RESULTS Fourteen orthopedic professionals reviewed 313 fluoroscopic images. Interrater reliability demonstrated marked improvement in assessment of whether the screw head was seated against the outer cortex of the ilium with the IOO view (kappa = 0.841, without IOO kappa = 0.027). There was a statistically significant difference in overall accuracy (p value < 0.001, OR = 1.57, 95% CI = 1.35-1.84) and whether the screw head was seated (p value < 0.001, OR = 8.14, 95% CI = 5.52-11.99) when compared with and without the IOO view (accuracy with IOO view: 85%, accuracy without IOO view: 78.26%; screw seated with IOO view: 93.93%, screw seated without IOO view: 65.54%). There was no significant difference (p value 0.465, OR = 1.13, 95% CI = 0.82-1.55) determining if the screw was in a safe position (safe with IOO view: 84.64%, safe without IOO view: 83.04%). CONCLUSIONS Our findings demonstrate that misinterpretation of sacroiliac and transsacral screw placement can occur with the standard fluoroscopic imaging. We suggest the addition of the IOO view increases the overall accuracy of screw placement and whether the screw head is fully seated against the outer table of the ilium. This in turn can improve fixation and potentially improve patient outcomes and decrease adverse events.
Collapse
Affiliation(s)
- Kurt Barger
- Orthopaedic Surgery, Riverside University Health System Medical Center, 26520 Cactus Ave, Moreno Valley, CA, 92555, USA.
| | - Matthew Robinson
- Orthopaedic Surgery, Riverside University Health System Medical Center, 26520 Cactus Ave, Moreno Valley, CA, 92555, USA
| |
Collapse
|
8
|
Zhao C, Wang Y, Wu X, Zhu G, Shi S. Design and evaluation of an intelligent reduction robot system for the minimally invasive reduction in pelvic fractures. J Orthop Surg Res 2022; 17:205. [PMID: 35379278 PMCID: PMC8981738 DOI: 10.1186/s13018-022-03089-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Accepted: 03/22/2022] [Indexed: 11/10/2022] Open
Abstract
Introduction Pelvic fracture is a severe high-energy injury with the highest disability and mortality of all fractures. Traditional open surgery is associated with extensive soft tissue damages and many complications. Minimally invasive surgery potentially mitigates the risks of open surgical procedures and is becoming a new standard for pelvic fracture treatment. The accurate reduction has been recognized as the cornerstone of minimally invasive surgery for pelvic fracture. At present, the closed reduction in pelvic fractures is limited by the current sub-optimal 2D intra-operative imaging (fluoroscopy) and by the high forces of soft tissue involved in the fragment manipulation, which might result in fracture malreduction. To overcome these shortcomings and facilitate pelvic fracture reduction, we developed an intelligent robot-assisted fracture reduction (RAFR) system for pelvic fracture. Methods The presented method is divided into three parts. The first part is the preparation of 20 pelvic fracture models. In the second part, we offer an automatic reduction algorithm of our robotic reduction system, including Intraoperative real-time 3D navigation, reduction path planning, control and fixation, and robotic-assisted fracture reduction. In the third part, image registration accuracy and fracture reduction accuracy were calculated and analyzed. Results All 20 pelvic fracture bone models were reduced by the RAFR system; the mean registration error E1 of the 20 models was 1.29 ± 0.57 mm. The mean reduction error E2 of the 20 models was 2.72 ± 0.82 mm. The global error analysis of registration and reduction results showed that higher errors are mainly located at the edge of the pelvis, such as the iliac wing. Conclusion The accuracy of image registration error and fracture reduction error in our study was excellent, which could reach the requirements of the clinical environment. Our study demonstrated the precision and effectiveness of our RAFR system and its applicability and usability in clinical practice, thus paving the way toward robot minimally invasive pelvic fracture surgeries.
Collapse
Affiliation(s)
- Chunpeng Zhao
- Department of Orthopedics and Traumatology, Beijing Jishuitan Hospital, Beijing, 100035, China
| | - Yu Wang
- School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China.,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100083, China
| | - Xinbao Wu
- Department of Orthopedics and Traumatology, Beijing Jishuitan Hospital, Beijing, 100035, China.
| | - Gang Zhu
- Rossum Robot Co., Ltd., Beijing, 100083, China
| | | |
Collapse
|
9
|
Lodde MF, Katthagen JC, Schopper CO, Zderic I, Richards RG, Gueorguiev B, Raschke MJ, Hartensuer R. Does Cement Augmentation of the Sacroiliac Screw Lead to Superior Biomechanical Results for Fixation of the Posterior Pelvic Ring? A Biomechanical Study. MEDICINA (KAUNAS, LITHUANIA) 2021; 57:medicina57121368. [PMID: 34946313 PMCID: PMC8706027 DOI: 10.3390/medicina57121368] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/03/2021] [Revised: 12/06/2021] [Accepted: 12/09/2021] [Indexed: 12/29/2022]
Abstract
Background and Objectives: The stability of the pelvic ring mainly depends on the integrity of its posterior part. Percutaneous sacroiliac (SI) screws are widely implanted as standard of care treatment. The main risk factors for their fixation failure are related to vertical shear or transforaminal sacral fractures. The aim of this study was to compare the biomechanical performance of fixations using one (Group 1) or two (Group 2) standard SI screws versus one SI screw with bone cement augmentation (Group 3). Materials and Methods: Unstable fractures of the pelvic ring (AO/OTA 61-C1.3, FFP IIc) were simulated in 21 artificial pelvises by means of vertical osteotomies in the ipsilateral anterior and posterior pelvic ring. A supra-acetabular external fixator was applied to address the anterior fracture. All specimens were tested under progressively increasing cyclic loading until failure, with monitoring by means of motion tracking. Fracture site displacement and cycles to failure were evaluated. Results: Fracture displacement after 500 cycles was lowest in Group 3 (0.76 cm [0.30] (median [interquartile range, IQR])) followed by Group 1 (1.42 cm, [0.21]) and Group 2 (1.42 cm [1.66]), with significant differences between Groups 1 and 3, p = 0.04. Fracture displacement after 1000 cycles was significantly lower in Group 3 (1.15 cm [0.37]) compared to both Group 1 (2.19 cm [2.39]) and Group 2 (2.23 cm [3.65]), p ≤ 0.04. Cycles to failure (Group 1: 3930 ± 890 (mean ± standard deviation), Group 2: 3676 ± 348, Group 3: 3764 ± 645) did not differ significantly between the groups, p = 0.79. Conclusions: In our biomechanical setup cement augmentation of one SI screw resulted in significantly less displacement compared to the use of one or two SI screws. However, the number of cycles to failure was not significantly different between the groups. Cement augmentation of one SI screw seems to be a useful treatment option for posterior pelvic ring fixation, especially in osteoporotic bone.
Collapse
Affiliation(s)
- Moritz F. Lodde
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland; (C.O.S.); (I.Z.); (R.G.R.); (B.G.)
- Department for Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus 1, Building W1, Waldeyerstraße 1, 48149 Münster, Germany; (J.C.K.); (M.J.R.); (R.H.)
- Correspondence: ; Tel.: +49-251-83-59264
| | - J. Christoph Katthagen
- Department for Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus 1, Building W1, Waldeyerstraße 1, 48149 Münster, Germany; (J.C.K.); (M.J.R.); (R.H.)
| | - Clemens O. Schopper
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland; (C.O.S.); (I.Z.); (R.G.R.); (B.G.)
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Johannes Kepler University Linz, 4040 Linz, Austria
| | - Ivan Zderic
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland; (C.O.S.); (I.Z.); (R.G.R.); (B.G.)
| | - R. Geoff Richards
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland; (C.O.S.); (I.Z.); (R.G.R.); (B.G.)
| | - Boyko Gueorguiev
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland; (C.O.S.); (I.Z.); (R.G.R.); (B.G.)
| | - Michael J. Raschke
- Department for Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus 1, Building W1, Waldeyerstraße 1, 48149 Münster, Germany; (J.C.K.); (M.J.R.); (R.H.)
| | - René Hartensuer
- Department for Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus 1, Building W1, Waldeyerstraße 1, 48149 Münster, Germany; (J.C.K.); (M.J.R.); (R.H.)
| |
Collapse
|
10
|
Lodde MF, Katthagen JC, Schopper CO, Zderic I, Richards G, Gueorguiev B, Raschke MJ, Hartensuer R. Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring. J Clin Med 2021; 10:jcm10112326. [PMID: 34073570 PMCID: PMC8199358 DOI: 10.3390/jcm10112326] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Revised: 05/22/2021] [Accepted: 05/24/2021] [Indexed: 12/17/2022] Open
Abstract
Background: Incidence of pelvic ring fractures has increased over the past four decades, especially after low-impact trauma—classified as fragility fractures of the pelvis (FFP). To date, there is a lack of biomechanical evidence for the superiority of one existing fixation technique over another. An FFP type IIc was simulated in 50 artificial pelvises, assigned to 5 study groups: Sacroiliac (SI) screw, SI screw plus supra-acetabular external fixator, SI screw plus plate, SI screw plus retrograde transpubic screw, or S1/S2 ala–ilium screws. The specimens were tested under progressively increasing cyclic loading. Axial stiffness and cycles to failure were analysed. Displacement at the fracture sites was evaluated, having been continuously captured via motion tracking. Results: Fixation with SI screw plus plate and SI screw plus retrograde transpubic screw led to higher stability than the other tested techniques. The S1/S2 ala–ilium screws were more stable than the SI screw or the SI screw plus external fixator. Conclusions: In cases with displaced fractures, open reduction and plate fixation provides the highest stability, whereas in cases where minimally invasive techniques are applicable, a retrograde transpubic screw or S1/S2 ala–ilium screws can be considered as successful alternative treatment options.
Collapse
Affiliation(s)
- Moritz F. Lodde
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland; (C.O.S.); (I.Z.); (G.R.); (B.G.)
- Department for Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus 1, Building W1, Waldeyerstraße 1, 48149 Münster, Germany; (J.C.K.); (M.J.R.); (R.H.)
- Correspondence: ; Tel.: +49-251-83-59264
| | - J. Christoph Katthagen
- Department for Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus 1, Building W1, Waldeyerstraße 1, 48149 Münster, Germany; (J.C.K.); (M.J.R.); (R.H.)
| | - Clemens O. Schopper
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland; (C.O.S.); (I.Z.); (G.R.); (B.G.)
| | - Ivan Zderic
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland; (C.O.S.); (I.Z.); (G.R.); (B.G.)
| | - Geoff Richards
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland; (C.O.S.); (I.Z.); (G.R.); (B.G.)
| | - Boyko Gueorguiev
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland; (C.O.S.); (I.Z.); (G.R.); (B.G.)
| | - Michael J. Raschke
- Department for Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus 1, Building W1, Waldeyerstraße 1, 48149 Münster, Germany; (J.C.K.); (M.J.R.); (R.H.)
| | - René Hartensuer
- Department for Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus 1, Building W1, Waldeyerstraße 1, 48149 Münster, Germany; (J.C.K.); (M.J.R.); (R.H.)
| |
Collapse
|