1
|
Quiros KAM, Nelson TM, Ulu A, Dominguez EC, Biddle TA, Lo DD, Nordgren TM, Eskandari M. A Comparative Study of Ex-Vivo Murine Pulmonary Mechanics Under Positive- and Negative-Pressure Ventilation. Ann Biomed Eng 2024; 52:342-354. [PMID: 37906375 PMCID: PMC10808462 DOI: 10.1007/s10439-023-03380-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 10/03/2023] [Indexed: 11/02/2023]
Abstract
Increased ventilator use during the COVID-19 pandemic resurrected persistent questions regarding mechanical ventilation including the difference between physiological and artificial breathing induced by ventilators (i.e., positive- versus negative-pressure ventilation, PPV vs NPV). To address this controversy, we compare murine specimens subjected to PPV and NPV in ex vivo quasi-static loading and quantify pulmonary mechanics via measures of quasi-static and dynamic compliances, transpulmonary pressure, and energetics when varying inflation frequency and volume. Each investigated mechanical parameter yields instance(s) of significant variability between ventilation modes. Most notably, inflation compliance, percent relaxation, and peak pressure are found to be consistently dependent on the ventilation mode. Maximum inflation volume and frequency note varied dependencies contingent on the ventilation mode. Contradictory to limited previous clinical investigations of oxygenation and end-inspiratory measures, the mechanics-focused comprehensive findings presented here indicate lung properties are dependent on loading mode, and importantly, these dependencies differ between smaller versus larger mammalian species despite identical custom-designed PPV/NPV ventilator usage. Results indicate that past contradictory findings regarding ventilation mode comparisons in the field may be linked to the chosen animal model. Understanding the differing fundamental mechanics between PPV and NPV may provide insights for improving ventilation strategies and design to prevent associated lung injuries.
Collapse
Affiliation(s)
- K A M Quiros
- Department of Mechanical Engineering, University of California Riverside, 900 University Ave., Riverside, CA, 92506, USA
| | - T M Nelson
- Department of Mechanical Engineering, University of California Riverside, 900 University Ave., Riverside, CA, 92506, USA
| | - A Ulu
- Division of Biomedical Sciences, Riverside School of Medicine, University of California, Riverside, CA, USA
| | - E C Dominguez
- Division of Biomedical Sciences, Riverside School of Medicine, University of California, Riverside, CA, USA
- Environmental Toxicology Graduate Program, University of California, Riverside, CA, USA
| | - T A Biddle
- Division of Biomedical Sciences, Riverside School of Medicine, University of California, Riverside, CA, USA
- Environmental Toxicology Graduate Program, University of California, Riverside, CA, USA
- School of Medicine, BREATHE Center, University of California, Riverside, CA, USA
| | - D D Lo
- Division of Biomedical Sciences, Riverside School of Medicine, University of California, Riverside, CA, USA
- School of Medicine, BREATHE Center, University of California, Riverside, CA, USA
- Center for Health Disparities Research, University of California, Riverside, CA, USA
| | - T M Nordgren
- Division of Biomedical Sciences, Riverside School of Medicine, University of California, Riverside, CA, USA
- Environmental Toxicology Graduate Program, University of California, Riverside, CA, USA
- School of Medicine, BREATHE Center, University of California, Riverside, CA, USA
- Department of Environmental and Radiological Health Sciences, Colorado State University, Fort Collins, CO, USA
| | - M Eskandari
- Department of Mechanical Engineering, University of California Riverside, 900 University Ave., Riverside, CA, 92506, USA.
- School of Medicine, BREATHE Center, University of California, Riverside, CA, USA.
- Department of Bioengineering, University of California, Riverside, CA, USA.
| |
Collapse
|
2
|
Xu H, Sheng S, Luo W, Xu X, Zhang Z. Acute respiratory distress syndrome heterogeneity and the septic ARDS subgroup. Front Immunol 2023; 14:1277161. [PMID: 38035100 PMCID: PMC10682474 DOI: 10.3389/fimmu.2023.1277161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Accepted: 10/30/2023] [Indexed: 12/02/2023] Open
Abstract
Acute respiratory distress syndrome (ARDS) is an acute diffuse inflammatory lung injury characterized by the damage of alveolar epithelial cells and pulmonary capillary endothelial cells. It is mainly manifested by non-cardiogenic pulmonary edema, resulting from intrapulmonary and extrapulmonary risk factors. ARDS is often accompanied by immune system disturbance, both locally in the lungs and systemically. As a common heterogeneous disease in critical care medicine, researchers are often faced with the failure of clinical trials. Latent class analysis had been used to compensate for poor outcomes and found that targeted treatment after subgrouping contribute to ARDS therapy. The subphenotype of ARDS caused by sepsis has garnered attention due to its refractory nature and detrimental consequences. Sepsis stands as the most predominant extrapulmonary cause of ARDS, accounting for approximately 32% of ARDS cases. Studies indicate that sepsis-induced ARDS tends to be more severe than ARDS caused by other factors, leading to poorer prognosis and higher mortality rate. This comprehensive review delves into the immunological mechanisms of sepsis-ARDS, the heterogeneity of ARDS and existing research on targeted treatments, aiming to providing mechanism understanding and exploring ideas for accurate treatment of ARDS or sepsis-ARDS.
Collapse
Affiliation(s)
- Huikang Xu
- Department of Critical Care Medicine, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
| | - Shiying Sheng
- Department of Critical Care Medicine, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
| | - Weiwei Luo
- Department of Critical Care Medicine, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
| | - Xiaofang Xu
- Department of Critical Care Medicine, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
| | - Zhaocai Zhang
- Department of Critical Care Medicine, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
- Key Laboratory of the Diagnosis and Treatment for Severe Trauma and Burn of Zhejiang Province, Hangzhou, China
- Zhejiang Province Clinical Research Center for Emergency and Critical Care Medicine, Hangzhou, China
| |
Collapse
|
3
|
Zersen KM. Setting the optimal positive end-expiratory pressure: a narrative review. Front Vet Sci 2023; 10:1083290. [PMID: 37538169 PMCID: PMC10395088 DOI: 10.3389/fvets.2023.1083290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Accepted: 06/27/2023] [Indexed: 08/05/2023] Open
Abstract
The primary goals of positive end-expiratory pressure (PEEP) are to restore functional residual capacity through recruitment and prevention of alveolar collapse. Through these mechanisms, PEEP improves arterial oxygenation and may reduce the risk of ventilator-induced lung injury (VILI). Because of the many potential negative effects associated with the use of PEEP, much research has concentrated on determining the optimal PEEP setting. Arterial oxygenation targets and pressure-volume loops have been utilized to set the optimal PEEP for decades. Several other techniques have been suggested, including the use of PEEP tables, compliance, driving pressure (DP), stress index (SI), transpulmonary pressures, imaging, and electrical impedance tomography. Each of these techniques has its own benefits and limitations and there is currently not one technique that is recommended above all others.
Collapse
|
4
|
Vizzoni L, Migone C, Grassiri B, Zambito Y, Ferro B, Roncucci P, Mori F, Salvatore A, Ascione E, Crea R, Esin S, Batoni G, Piras AM. Biopharmaceutical Assessment of Mesh Aerosolised Plasminogen, a Step towards ARDS Treatment. Pharmaceutics 2023; 15:1618. [PMID: 37376068 PMCID: PMC10300680 DOI: 10.3390/pharmaceutics15061618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 05/18/2023] [Accepted: 05/26/2023] [Indexed: 06/29/2023] Open
Abstract
Acute respiratory distress syndrome (ARDS) is a severe complication of lung injuries, commonly associated with bacterial, fungal and viral infections, including SARS-CoV-2 viral infections. ARDS is strongly correlated with patient mortality and its clinical management is very complex, with no effective treatment presently available. ARDS involves severe respiratory failure, fibrin deposition in both airways and lung parenchyma, with the development of an obstructing hyaline membrane drastically limiting gas exchange. Moreover, hypercoagulation is related to deep lung inflammation, and a pharmacological action toward both aspects is expected to be beneficial. Plasminogen (PLG) is a main component of the fibrinolytic system playing key roles in various inflammation regulatory processes. The inhalation of PLG has been proposed in the form of the off-label administration of an eyedrop solution, namely, a plasminogen-based orphan medicinal product (PLG-OMP), by means of jet nebulisation. Being a protein, PLG is susceptible to partial inactivation under jet nebulisation. The aim of the present work is to demonstrate the efficacy of the mesh nebulisation of PLG-OMP in an in vitro simulation of clinical off-label administration, considering both the enzymatic and immunomodulating activities of PLG. Biopharmaceutical aspects are also investigated to corroborate the feasibility of PLG-OMP administration by inhalation. The nebulisation of the solution was performed using an Aerogen® SoloTM vibrating-mesh nebuliser. Aerosolised PLG showed an optimal in vitro deposition profile, with 90% of the active ingredient impacting the lower portions of a glass impinger. The nebulised PLG remained in its monomeric form, with no alteration of glycoform composition and 94% of enzymatic activity maintenance. Activity loss was observed only when PLG-OMP nebulisation was performed under simulated clinical oxygen administration. In vitro investigations evidenced good penetration of aerosolised PLG through artificial airway mucus, as well as poor permeation across an Air-Liquid Interface model of pulmonary epithelium. The results suggest a good safety profile of inhalable PLG, excluding high systemic absorption but with good mucus diffusion. Most importantly, the aerosolised PLG was capable of reversing the effects of an LPS-activated macrophage RAW 264.7 cell line, demonstrating the immunomodulating activity of PLG in an already induced inflammatory state. All physical, biochemical and biopharmaceutical assessments of mesh aerosolised PLG-OMP provided evidence for its potential off-label administration as a treatment for ARDS patients.
Collapse
Affiliation(s)
- Lucia Vizzoni
- Department of Pharmacy, University of Pisa, 56126 Pisa, Italy
- Department of Life Sciences, University of Siena, 53100 Siena, Italy
| | - Chiara Migone
- Department of Pharmacy, University of Pisa, 56126 Pisa, Italy
| | | | - Ylenia Zambito
- Department of Pharmacy, University of Pisa, 56126 Pisa, Italy
- Research Centre for Nutraceutical and Healthy Foods “NUTRAFOOD”, University of Pisa, 56124 Pisa, Italy
| | - Baldassare Ferro
- Anestesia e Rianimazione, Azienda USL Toscana Nord Ovest, 57124 Livorno, Italy
| | - Paolo Roncucci
- Anestesia e Rianimazione, Azienda USL Toscana Nord Ovest, 57124 Livorno, Italy
| | - Filippo Mori
- Kedrion S.p.A., Via di Fondovalle, Loc. Bolognana, 55027 Gallicano, Italy
| | - Alfonso Salvatore
- Kedrion S.p.A., Via di Fondovalle, Loc. Bolognana, 55027 Gallicano, Italy
| | - Ester Ascione
- Kedrion S.p.A., Via di Fondovalle, Loc. Bolognana, 55027 Gallicano, Italy
| | - Roberto Crea
- Kedrion S.p.A., Via di Fondovalle, Loc. Bolognana, 55027 Gallicano, Italy
| | - Semih Esin
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
- Centre for Instrument Sharing of University of Pisa (CISUP), 56126 Pisa, Italy
| | - Giovanna Batoni
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
- Centre for Instrument Sharing of University of Pisa (CISUP), 56126 Pisa, Italy
| | - Anna Maria Piras
- Department of Pharmacy, University of Pisa, 56126 Pisa, Italy
- Centre for Instrument Sharing of University of Pisa (CISUP), 56126 Pisa, Italy
| |
Collapse
|
5
|
Quiros KAM, Nelson TM, Sattari S, Mariano CA, Ulu A, Dominguez EC, Nordgren TM, Eskandari M. Mouse lung mechanical properties under varying inflation volumes and cycling frequencies. Sci Rep 2022; 12:7094. [PMID: 35501363 PMCID: PMC9059689 DOI: 10.1038/s41598-022-10417-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Accepted: 03/30/2022] [Indexed: 01/23/2023] Open
Abstract
Respiratory pathologies alter the structure of the lung and impact its mechanics. Mice are widely used in the study of lung pathologies, but there is a lack of fundamental mechanical measurements assessing the interdependent effect of varying inflation volumes and cycling frequency. In this study, the mechanical properties of five male C57BL/6J mice (29-33 weeks of age) lungs were evaluated ex vivo using our custom-designed electromechanical, continuous measure ventilation apparatus. We comprehensively quantify and analyze the effect of loading volumes (0.3, 0.5, 0.7, 0.9 ml) and breathing rates (5, 10, 20 breaths per minute) on pulmonary inflation and deflation mechanical properties. We report means of static compliance between 5.4-16.1 µl/cmH2O, deflation compliance of 5.3-22.2 µl/cmH2O, percent relaxation of 21.7-39.1%, hysteresis of 1.11-7.6 ml•cmH2O, and energy loss of 39-58% for the range of four volumes and three rates tested, along with additional measures. We conclude that inflation volume was found to significantly affect hysteresis, static compliance, starting compliance, top compliance, deflation compliance, and percent relaxation, and cycling rate was found to affect only hysteresis, energy loss, percent relaxation, static compliance and deflation compliance.
Collapse
Affiliation(s)
- K A M Quiros
- Department of Mechanical Engineering, University of California, Riverside, CA, USA
| | - T M Nelson
- Department of Mechanical Engineering, University of California, Riverside, CA, USA
| | - S Sattari
- Department of Mechanical Engineering, University of California, Riverside, CA, USA
| | - C A Mariano
- Department of Mechanical Engineering, University of California, Riverside, CA, USA
| | - A Ulu
- BREATHE Center, School of Medicine, University of California, Riverside, CA, USA
- Division of Biomedical Sciences, School of Medicine, University of California Riverside, Riverside, CA, USA
| | - E C Dominguez
- BREATHE Center, School of Medicine, University of California, Riverside, CA, USA
- Division of Biomedical Sciences, School of Medicine, University of California Riverside, Riverside, CA, USA
| | - T M Nordgren
- BREATHE Center, School of Medicine, University of California, Riverside, CA, USA
- Division of Biomedical Sciences, School of Medicine, University of California Riverside, Riverside, CA, USA
- Department of Environmental and Radiological Health Sciences, Colorado State University, Fort Collins, CO, USA
| | - M Eskandari
- Department of Mechanical Engineering, University of California, Riverside, CA, USA.
- BREATHE Center, School of Medicine, University of California, Riverside, CA, USA.
- Department of Bioengineering, University of California, Riverside, CA, USA.
| |
Collapse
|
6
|
Huang X, Xu L, Pei Y, Huang H, Chen C, Tang W, Jiang X, Li Y. The Association Between Oxygenation Status at 24 h After Diagnosis of Pulmonary Acute Respiratory Distress Syndrome and the 30-Day Mortality among Pediatric Oncological Patients. Front Pediatr 2022; 10:805264. [PMID: 35633973 PMCID: PMC9130705 DOI: 10.3389/fped.2022.805264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2021] [Accepted: 04/21/2022] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND Pediatric oncology patients with acute respiratory distress syndrome (ARDS) secondary to pneumonia are at high risk of mortality. Our aim was to describe the epidemiology of ARDS in this clinical population and to identify the association between the oxygenation status at 24 h after diagnosis and the 30-day mortality rates, stratified by the severity of ARDS. METHODS This was a retrospective cohort study of 82 pediatric oncology patients, with a median age of 4 years, admitted to our pediatric intensive care unit with a diagnosis of ARDS between 2013 and 2021. Demographic and clinical factors were compared between the survivor (n = 52) and non-survivor (n = 30) groups. Univariate and multivariate Cox proportional hazards regression models were used to determine the association between the oxygenation status at 24 h after diagnosis and the 30-day mortality rates. RESULTS The mean airway pressure at ARDS diagnosis, PaO2/FiO2 (P/F) ratio, oxygenation index (OI) value, peak inspiratory pressure, and lactate level at 24 h after ARDS diagnosis, as well as complications (i.e., septicemia and more than two extrapulmonary organ failures) and adjunctive continuous renal replacement therapy, were significant mortality risk factors. After adjusting for other covariates, the oxygenation status P/F ratio (Hazard ratio [HR] = 0.98, 95% confidence interval [CI] = 0.96-1.00, P = 0.043) and OI value (HR = 1.12, 95% CI = 1.02-1.23, P = 0.016) at 24 h remained independent mortality risk factors. According to the Kaplan-Meier survival curve, a low P/F ratio (≤ 150) and high OI (>10) were associated with a higher risk of 30-day mortality (50.9 and 52.9%, respectively; both P < 0.05). CONCLUSION The P/F ratio and OI value measured at 24 h after ARDS diagnosis can provide a better stratification of patients according to ARDS disease severity to predict the 30-day mortality risk.
Collapse
Affiliation(s)
- Xueqiong Huang
- Department of Pediatrics, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Lingling Xu
- Department of Pediatrics, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Yuxin Pei
- Department of Pediatrics, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Huimin Huang
- Department of Pediatrics, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Chao Chen
- Department of Pediatrics, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Wen Tang
- Department of Pediatrics, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Xiaoyun Jiang
- Department of Pediatrics, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Yijuan Li
- Department of Pediatrics, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| |
Collapse
|
7
|
Hendrickson KW, Peltan ID, Brown SM. The Epidemiology of Acute Respiratory Distress Syndrome Before and After Coronavirus Disease 2019. Crit Care Clin 2021; 37:703-716. [PMID: 34548129 PMCID: PMC8449138 DOI: 10.1016/j.ccc.2021.05.001] [Citation(s) in RCA: 45] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- Kathryn W Hendrickson
- Division of Pulmonary and Critical Care Medicine, Department of Medicine, University of Utah School of Medicine, 26 North 1900 East, Salt Lake City, UT 84112, USA; Division of Pulmonary and Critical Care Medicine, Department of Medicine, Intermountain Medical Center
| | - Ithan D Peltan
- Division of Pulmonary and Critical Care Medicine, Department of Medicine, University of Utah School of Medicine, 26 North 1900 East, Salt Lake City, UT 84112, USA; Pulmonary Division, Department of Medicine, Intermountain Medical Center, 5121 South Cottonwood Street, Murray, UT 84107, USA
| | - Samuel M Brown
- Division of Pulmonary and Critical Care Medicine, Department of Medicine, University of Utah School of Medicine, 26 North 1900 East, Salt Lake City, UT 84112, USA; Division of Pulmonary and Critical Care Medicine, Department of Medicine, Intermountain Medical Center.
| |
Collapse
|
8
|
Reilly JP, Calfee CS, Christie JD. Acute Respiratory Distress Syndrome Phenotypes. Semin Respir Crit Care Med 2019; 40:19-30. [PMID: 31060085 DOI: 10.1055/s-0039-1684049] [Citation(s) in RCA: 78] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
The acute respiratory distress syndrome (ARDS) phenotype was first described over 50 years ago and since that time significant progress has been made in understanding the biologic processes underlying the syndrome. Despite this improved understanding, no pharmacologic therapies aimed at the underlying biology have been proven effective in ARDS. Increasingly, ARDS has been recognized as a heterogeneous syndrome characterized by subphenotypes with distinct clinical, radiographic, and biologic differences, distinct outcomes, and potentially distinct responses to therapy. The Berlin Definition of ARDS specifies three severity classifications: mild, moderate, and severe based on the PaO2 to FiO2 ratio. Two randomized controlled trials have demonstrated a potential benefit to prone positioning and neuromuscular blockade in moderate to severe phenotypes of ARDS only. Precipitating risk factor, direct versus indirect lung injury, and timing of ARDS onset can determine other clinical phenotypes of ARDS after admission. Radiographic phenotypes of ARDS have been described based on a diffuse versus focal pattern of infiltrates on chest imaging. Finally and most promisingly, biologic subphenotypes or endotypes have increasingly been identified using plasma biomarkers, genetics, and unbiased approaches such as latent class analysis. The potential of precision medicine lies in identifying novel therapeutics aimed at ARDS biology and the subpopulation within ARDS most likely to respond. In this review, we discuss the challenges and approaches to subphenotype ARDS into clinical, radiologic, severity, and biologic phenotypes with an eye toward the future of precision medicine in critical care.
Collapse
Affiliation(s)
- John P Reilly
- Division of Pulmonary, Allergy, and Critical Care, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Carolyn S Calfee
- Department of Medicine and Anesthesia, University of California, San Francisco, San Francisco, California
| | - Jason D Christie
- Division of Pulmonary, Allergy, and Critical Care, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| |
Collapse
|
9
|
Nabian M, Narusawa U. Quasi-static pulmonary P–V curves of patients with ARDS, Part I: Characterization. Respir Physiol Neurobiol 2018; 248:36-42. [DOI: 10.1016/j.resp.2017.10.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2017] [Revised: 10/23/2017] [Accepted: 10/28/2017] [Indexed: 01/07/2023]
|
10
|
Nabian M, Narusawa U. Patient-specific optimization of mechanical ventilation for patients with acute respiratory distress syndrome using quasi-static pulmonary P-V data. INFORMATICS IN MEDICINE UNLOCKED 2018; 12:44-55. [PMID: 35036518 PMCID: PMC8740849 DOI: 10.1016/j.imu.2018.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2018] [Revised: 06/05/2018] [Accepted: 06/06/2018] [Indexed: 11/13/2022] Open
Abstract
Quasi-static, pulmonary pressure-volume (P-V) curves were combined with a respiratory system model to analyze tidal pressure cycles, simulating mechanical ventilation of patients with acute respiratory distress syndrome (ARDS). Two important quantities including 1) tidal recruited volume and 2) tidal hyperinflated volume were analytically computed by integrating the distribution of alveolar elements over the affected pop-open pressure range. We analytically predicted the tidal recruited volume of four canine subjects and compared our results with similar experimental measurements on canine models for the validation. We then applied our mathematical model to the P-V data of ARDS populations in four stages of Early ARDS, Deep Knee, Advanced ARDS and Baby Lung to quantify the tidal recruited volume and tidal hyperinflated volume as an indicator of ventilator-induced lung injury (VILI). These quantitative predictions based on patient-specific P-V data suggest that the optimum parameters of mechanical ventilation including PEEP and Tidal Pressure (Volume) are largely varying among ARDS population and are primarily influenced by the degree in the severity of ARDS.
Collapse
Affiliation(s)
- Mohsen Nabian
- Department of Mechanical and Industrial Engineering, Northeastern University, Boston, MA, USA
| | - Uichiro Narusawa
- Department of Mechanical and Industrial Engineering, Northeastern University, Boston, MA, USA
- Department of Bio-engineering, Northeastern University, Boston, MA, USA
| |
Collapse
|
11
|
Pan C, Chen L, Zhang YH, Liu W, Urbino R, Ranieri VM, Qiu HB, Yang Y. Physiological Correlation of Airway Pressure and Transpulmonary Pressure Stress Index on Respiratory Mechanics in Acute Respiratory Failure. Chin Med J (Engl) 2017; 129:1652-7. [PMID: 27411451 PMCID: PMC4960953 DOI: 10.4103/0366-6999.185855] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
BACKGROUND Stress index at post-recruitment maneuvers could be a method of positive end-expiratory pressure (PEEP) titration in acute respiratory distress syndrome (ARDS) patients. However, airway pressure (Paw) stress index may not reflect lung mechanics in the patients with high chest wall elastance. This study was to evaluate the Pawstress index on lung mechanics and the correlation between Pawstress index and transpulmonary pressure (PL) stress index in acute respiratory failure (ARF) patients. METHODS Twenty-four ARF patients with mechanical ventilation (MV) were consecutively recruited from July 2011 to April 2013 in Zhongda Hospital, Nanjing, China and Ospedale S. Giovanni Battista-Molinette Hospital, Turin, Italy. All patients underwent MV with volume control (tidal volume 6 ml/kg) for 20 min. PEEP was set according to the ARDSnet study protocol. The patients were divided into two groups according to the chest wall elastance/respiratory system elastance ratio. The high elastance group (H group, n = 14) had a ratio ≥30%, and the low elastance group (L group, n = 10) had a ratio <30%. Respiratory elastance, gas-exchange, Pawstress index, and PLstress index were measured. Student's t-test, regression analysis, and Bland-Altman analysis were used for statistical analysis. RESULTS Pneumonia was the major cause of respiratory failure (71.0%). Compared with the L group, PEEP was lower in the H group (5.7 ± 1.7 cmH2O vs. 9.0 ± 2.3 cmH2O, P < 0.01). Compared with the H group, lung elastance was higher (20.0 ± 7.8 cmH2O/L vs. 11.6 ± 3.6 cmH2O/L, P < 0.01), and stress was higher in the L group (7.0 ± 1.9 vs. 4.9 ± 1.9, P = 0.02). A linear relationship was observed between the Pawstress index and the PLstress index in H group (R2 = 0.56, P < 0.01) and L group (R2 = 0.85, P < 0.01). CONCLUSION In the ARF patients with MV, Pawstress index can substitute for PLto guide ventilator settings. TRIAL REGISTRATION ClinicalTrials.gov NCT02196870 (https://clinicaltrials.gov/ct2/show/NCT02196870).
Collapse
Affiliation(s)
- Chun Pan
- Department of Critical Care Medicine, Zhongda Hospital, Medical School, Southeast University, Nanjing, Jiangsu 210009, China
| | - Lu Chen
- Department of Critical Care Medicine, Beijing Tiantan Hospital, Capital Medical University, Beijing 100050, China
| | - Yun-Hang Zhang
- Department of Critical Care Medicine, Zhongda Hospital, Medical School, Southeast University, Nanjing, Jiangsu 210009, China
| | - Wei Liu
- Department of Biopharmaceutics, School of Life Science and Technology, Chinese Pharmaceutical University, Nanjing, Jiangsu 210009, China
| | - Rosario Urbino
- Department of Anesthesiology and Critical Care Medicine, Ospedale S. Giovanni Battista-Molinette, Turin 10126, Italy
| | - V Marco Ranieri
- Department of Anesthesiology and Critical Care Medicine, Ospedale S. Giovanni Battista-Molinette, Turin 10126, Italy
| | - Hai-Bo Qiu
- Department of Critical Care Medicine, Zhongda Hospital, Medical School, Southeast University, Nanjing, Jiangsu 210009, China
| | - Yi Yang
- Department of Critical Care Medicine, Zhongda Hospital, Medical School, Southeast University, Nanjing, Jiangsu 210009, China
| |
Collapse
|
12
|
Henderson WR, Molgat-Seon Y, Dominelli PB, Brasher PMA, Griesdale DEG, Foster GE, Yacyshyn A, Ayas NT, Sheel AW. Gas density alters expiratory time constants before and after experimental lung injury. Exp Physiol 2016; 100:1217-28. [PMID: 26289254 DOI: 10.1113/ep085205] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2015] [Accepted: 08/17/2015] [Indexed: 01/10/2023]
Abstract
NEW FINDINGS What is the central question of this study? Does the induction of a model of lung injury affect the expiratory time constant (τE) in terms of either total duration or morphology? Does ventilation with gases of different densities alter the duration or morphology of τE either before or after injury? What is the main finding and its importance? The use of sulfur hexafluoride in ventilating gas mixtures lengthens total expiratory time constants before and after lung injury compared with both nitrogen and helium mixtures. Sulfur hexafluoride mixtures also decrease the difference and variability of τE between fast- and slow-emptying compartments before and after injury when compared with nitrogen and helium mixtures. Acute lung injury is characterized by regional heterogeneity of lung resistance and elastance that may lead to regional heterogeneity of expiratory time constants (τE). We hypothesized that increasing airflow resistance by using inhaled sulfur hexafluoride (SF6) would lengthen time constants and decrease their heterogeneity in an experimental model of lung injury when compared with nitrogen or helium mixtures. To overcome the limitations of a single-compartment model, we employed a multisegment model of expiratory gas flow. An experimental model of lung injury was created using intratracheal injection of sodium polyacrylate in anaesthetized and mechanically ventilated female Yorkshire-cross pigs (n = 7). The animals were ventilated with 50% O2 and the remaining 50% as nitrogen (N2), helium (He) or sulfur hexafluoride (SF6). Values for τE decreased with injury and were more variable after injury than before (P < 0.001). Values for τE increased throughout expiration both before and after injury, and the rate of increase in τE was lessened by SF6 (P < 0.001 when compared with N2 both before and after injury). Altering the inhaled gas density did not affect indices of oxygenation, dead space or shunt. The use of SF6 in ventilating gas mixtures lengthens total expiratory time constants before and after lung injury compared with both N2 and He mixtures. Importantly, SF6 mixtures also decrease the difference and variability of τE between fast- and slow-emptying compartments before and after injury when compared with N2 and He mixtures.
Collapse
Affiliation(s)
- William R Henderson
- Division of Critical Care Medicine, Department of Medicine, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada.,School of Kinesiology, University of British Columbia, Vancouver, British Columbia, Canada
| | - Yannick Molgat-Seon
- School of Kinesiology, University of British Columbia, Vancouver, British Columbia, Canada
| | - Paolo B Dominelli
- School of Kinesiology, University of British Columbia, Vancouver, British Columbia, Canada
| | - Penelope M A Brasher
- Centre for Clinical Epidemiology & Evaluation, Vancouver Coastal Health Research Institute, Vancouver, British Columbia, Canada
| | - Donald E G Griesdale
- Division of Critical Care Medicine, Department of Medicine, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
| | - Glen E Foster
- Centre for Heart, Lung and Vascular Health, School of Health and Exercise Sciences, University of British Columbia, Kelowna, British Columbia, Canada
| | - Alexandra Yacyshyn
- Centre for Heart, Lung and Vascular Health, School of Health and Exercise Sciences, University of British Columbia, Kelowna, British Columbia, Canada
| | - Najib T Ayas
- Division of Critical Care Medicine, Department of Medicine, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
| | - A William Sheel
- School of Kinesiology, University of British Columbia, Vancouver, British Columbia, Canada
| |
Collapse
|
13
|
Dissipated Energy is a Key Mediator of VILI: Rationale for Using Low Driving Pressures. ANNUAL UPDATE IN INTENSIVE CARE AND EMERGENCY MEDICINE 2016. [DOI: 10.1007/978-3-319-27349-5_25] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
14
|
Clinical and biological heterogeneity in acute respiratory distress syndrome: direct versus indirect lung injury. Clin Chest Med 2014; 35:639-53. [PMID: 25453415 DOI: 10.1016/j.ccm.2014.08.004] [Citation(s) in RCA: 99] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
The acute respiratory distress syndrome (ARDS) is a heterogeneous group of illnesses affecting the pulmonary parenchyma with acute onset bilateral inflammatory pulmonary infiltrates with associated hypoxemia. ARDS occurs after 2 major types of pulmonary injury: direct lung injury affecting the lung epithelium or indirect lung injury disrupting the vascular endothelium. Greater understanding of the differences between direct and indirect lung injury may refine the classification of patients with ARDS and lead to development of new therapeutics targeted at specific subpopulations of patients with ARDS.
Collapse
|
15
|
Henderson WR, Barnbrook J, Dominelli PB, Griesdale DE, Arndt T, Molgat-Seon Y, Foster G, Ackland GL, Xu J, Ayas NT, Sheel AW. Administration of intrapulmonary sodium polyacrylate to induce lung injury for the development of a porcine model of early acute respiratory distress syndrome. Intensive Care Med Exp 2014; 2:5. [PMID: 26266906 PMCID: PMC4513039 DOI: 10.1186/2197-425x-2-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2013] [Accepted: 01/10/2014] [Indexed: 12/15/2022] Open
Abstract
Background The loss of alveolar epithelial and endothelial integrity is a central component in acute respiratory distress syndrome (ARDS); however, experimental models investigating the mechanisms of epithelial injury are lacking. The purpose of the present study was to design and develop an experimental porcine model of ARDS by inducing lung injury with intrapulmonary administration of sodium polyacrylate (SPA). Methods The present study was performed at the Centre for Comparative Medicine, University of British Columbia, Vancouver, British Columbia. Human alveolar epithelial cells were cultured with several different concentrations of SPA; a bioluminescence technique was used to assess cell death associated with each concentration. In the anesthetized pig model (female Yorkshire X pigs (n = 14)), lung injury was caused in 11 animals (SPA group) by injecting sequential aliquots (5 mL) of 1% SPA gel in aqueous solution into the distal airway via a rubber catheter through an endotracheal tube. The SPA was dispersed throughout the lungs by manual bag ventilation. Three control animals (CON group) underwent all experimental procedures and measurements with the exception of SPA administration. Results The mean (± SD) ATP concentration after incubation of human alveolar epithelial cells with 0.1% SPA (0.92 ± 0.27 μM/well) was approximately 15% of the value found for the background control (6.30 ± 0.37 μM/well; p < 0.001). Elastance of the respiratory system (ERS) and the lung (EL) increased in SPA-treated animals after injury (p = 0.003 and p < 0.001, respectively). Chest wall elastance (ECW) did not change in SPA-treated animals. There were no differences in ERS,EL, or ECW in the CON group when pre- and post-injury values were compared. Analysis of bronchoalveolar lavage fluid showed a significant shift toward neutrophil predominance from before to after injury in SPA-treated animals (p < 0.001) but not in the CON group (p = 0.38). Necropsy revealed marked consolidation and congestion of the dorsal lung lobes in SPA-treated animals, with light-microscopy evidence of bronchiolar and alveolar spaces filled with neutrophilic infiltrate, proteinaceous debris, and fibrin deposition. These findings were absent in animals in the CON group. Electron microscopy of lung tissue from SPA-treated animals revealed injury to the alveolar epithelium and basement membranes, including intra-alveolar neutrophils and fibrin on the alveolar surface and intravascular fibrin (microthrombosis). Conclusions In this particular porcine model, the nonimmunogenic polymer SPA caused a rapid exudative lung injury. This model may be useful to study ARDS caused by epithelial injury and inflammation.
Collapse
Affiliation(s)
- William R Henderson
- Wolfson Institute for Biomedical Research, Department of Medicine, University College London, London, WC1E 6BT, UK,
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Tejera P, Meyer NJ, Chen F, Feng R, Zhao Y, O'Mahony DS, Li L, Sheu CC, Zhai R, Wang Z, Su L, Bajwa E, Ahasic AM, Clardy PF, Gong MN, Frank AJ, Lanken PN, Thompson BT, Christie JD, Wurfel MM, O'Keefe GE, Christiani DC. Distinct and replicable genetic risk factors for acute respiratory distress syndrome of pulmonary or extrapulmonary origin. J Med Genet 2012; 49:671-80. [PMID: 23048207 DOI: 10.1136/jmedgenet-2012-100972] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
BACKGROUND The role of genetics in the development of acute lung injury (ALI)/acute respiratory distress syndrome (ARDS) from direct or indirect lung injury has not been specifically investigated. The aim of this study was to identify genetic variants contributing to ALI/ARDS from pulmonary or extrapulmonary causes. METHODS We conducted a multistage genetic association study. We first performed a large-scale genotyping (50K ITMAT-Broad_CARe Chip) in 1717 critically ill Caucasian patients with either pulmonary or extrapulmonary injury, to identify single nucleotide polymorphisms (SNPs) associated with the development of ARDS from direct or indirect insults to the lung. Identified SNPs (p≤0.0005) were validated in two separated populations (Stage II), with trauma (Population I; n=765) and pneumonia/pulmonary sepsis (Population II; n=838), as causes for ALI/ARDS. Genetic variants replicating their association with trauma related-ALI in Stage II were validated in a second trauma-associated ALI population (n=224, Stage III). RESULTS In Stage I, non-overlapping SNPs were significantly associated with ARDS from direct/indirect lung injury, respectively. The association between rs1190286 (POPDC3) and reduced risk of ARDS from pulmonary injury was validated in Stage II (p<0.003). SNP rs324420 (FAAH) was consistently associated with increased risk of ARDS from extrapulmonary causes in two independent ALI-trauma populations (p<0.006, Stage II; p<0.05, Stage III). Meta-analysis confirmed these associations. CONCLUSIONS Different genetic variants may influence ARDS susceptibility depending on direct versus indirect insults. Functional SNPs in POPDC3 and FAAH genes may be driving the association with direct and indirect ALI/ARDS, respectively.
Collapse
Affiliation(s)
- Paula Tejera
- Department of Environmental Health, Harvard School of Public Health, Boston, MA 02115, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Ragaller M, Richter T. Acute lung injury and acute respiratory distress syndrome. J Emerg Trauma Shock 2010; 3:43-51. [PMID: 20165721 PMCID: PMC2823143 DOI: 10.4103/0974-2700.58663] [Citation(s) in RCA: 91] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2009] [Accepted: 10/30/2009] [Indexed: 01/11/2023] Open
Abstract
Every year, more information accumulates about the possibility of treating patients with acute lung injury or acute respiratory distress syndrome with specially designed mechanical ventilation strategies. Ventilator modes, positive end-expiratory pressure settings, and recruitment maneuvers play a major role in these strategies. However, what can we take from these experimental and clinical data to the clinical practice? In this article, we discuss substantial options of mechanical ventilation together with some adjunctive therapeutic measures, such as prone positioning and inhalation of nitric oxide.
Collapse
Affiliation(s)
- Maximillian Ragaller
- Department of Anesthesiology and Intensive Care Medicine, University Hospital Carl Gustav Carus, Dresden, Germany
| | - Torsten Richter
- Department of Anesthesiology and Intensive Care Medicine, University Hospital Carl Gustav Carus, Dresden, Germany
| |
Collapse
|
18
|
Sundaresan A, Yuta T, Hann CE, Chase JG, Shaw GM. A minimal model of lung mechanics and model-based markers for optimizing ventilator treatment in ARDS patients. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2009; 95:166-180. [PMID: 19327863 DOI: 10.1016/j.cmpb.2009.02.008] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2008] [Revised: 12/22/2008] [Accepted: 02/20/2009] [Indexed: 05/27/2023]
Abstract
A majority of patients admitted to the Intensive Care Unit (ICU) require some form of respiratory support. In the case of Acute Respiratory Distress Syndrome (ARDS), the patient often requires full intervention from a mechanical ventilator. ARDS is also associated with mortality rate as high as 70%. Despite many recent studies on ventilator treatment of the disease, there are no well established methods to determine the optimal Positive End-Expiratory Pressure (PEEP) or other critical ventilator settings for individual patients. A model of fundamental lung mechanics is developed based on capturing the recruitment status of lung units. The main objective of this research is to develop a minimal model that is clinically effective in determining PEEP. The model was identified for a variety of different ventilator settings using clinical data. The fitting error was between 0.1% and 4% over the inflation limb and between 0.3% and 13% over the deflation limb at different PEEP settings. The model produces good correlation with clinical data, and is clinically applicable due to the minimal number of patient specific parameters to identify. The ability to use this identified patient specific model to optimize ventilator management is demonstrated by its ability to predict the patient specific response of PEEP changes before clinically applying them. Predictions of recruited lung volume change with change in PEEP have a median absolute error of 1.87% (IQR: 0.93-4.80%; 90% CI: 0.16-11.98%) for inflation and a median of 5.76% (IQR: 2.71-10.50%; 90% CI: 0.43-17.04%) for deflation, across all data sets and PEEP values (N=34predictions). This minimal model thus provides a clinically useful and relatively simple platform for continuous patient specific monitoring of lung unit recruitment for a patient.
Collapse
Affiliation(s)
- Ashwath Sundaresan
- Center for BioEngineering, Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, New Zealand.
| | | | | | | | | |
Collapse
|
19
|
Gordo-Vidal F, Gómez-Tello V, Palencia-Herrejón E, Latour-Pérez J, Sánchez-Artola B, Díaz-Alersi R. [High PEEP vs. conventional PEEP in the acute respiratory distress syndrome: a systematic review and meta-analysis]. Med Intensiva 2008; 31:491-501. [PMID: 18039449 DOI: 10.1016/s0210-5691(07)74856-8] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
OBJECTIVE To perform a systematic review and meta-analysis of the literature to evaluate the effects of high PEEP versus conventional PEEP on mortality and on the risk of barotrauma in patients with the acute respiratory distress syndrome (ARDS). SOURCE OF DATA Computer search of Medline, Embase, CINAHL, CANCERLIT, Pascal-Biomed, ACP Journal Club, Cochrane library (CDSR, DARE, CCTR), ISI Proceedings, Current Contents, and Web of Science, as well as manual search of selected references. SELECTION OF STUDIES Controlled random clinical trials published after NAECC (1994) that evaluated the effect of two levels of PEEP and that reported the mortality and incidence of barotrauma in the series. DATA EXTRACTION By two investigators working independently, with discrepancies resolved by group consensus. Contingency tables were elaborated and the RRs with corresponding confidence intervals were obtained for each study. RESULTS Four articles were selected for the meta-analysis of mortality and three for the meta-analysis of barotrauma. No effects of PEEP level on mortality were found (RR 0.73, 95% CI: 0.49 to 1.10) or on the incidence of barotrauma (RR 0.50, 95% CI: 0.14 to 1.73). However, an analysis of the studies in which PEEP was individualized in function of Pflex showed a significant decrease in mortality (RR 0.59, 95% CI: 0.43 to 0.82) (p=0.001) CONCLUSIONS The use of high or conventional PEEP in function of oxygenation does not affect mortality or the incidence of barotrauma in patients with ARDS. However, there might be a decrease in mortality associated to high PEEP individualized in function of the pulmonary mechanics of each patient.
Collapse
Affiliation(s)
- F Gordo-Vidal
- Unidad de Cuidados Intensivos, Fundación Hospital Alcorcón, Madrid, España.
| | | | | | | | | | | |
Collapse
|
20
|
Pulmonary and extrapulmonary acute respiratory distress syndrome: myth or reality? Curr Opin Crit Care 2008; 14:50-5. [DOI: 10.1097/mcc.0b013e3282f2405b] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
21
|
LaFollette R, Hojnowski K, Norton J, DiRocco J, Carney D, Nieman G. Using pressure-volume curves to set proper PEEP in acute lung injury. Nurs Crit Care 2007; 12:231-41. [PMID: 17883616 DOI: 10.1111/j.1478-5153.2007.00224.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The evolution of respiratory care on patients with acute respiratory distress syndrome (ARDS) has been focused on preventing the deleterious effects of mechanical ventilation, termed ventilator-induced lung injury (VILI). Currently, reduced tidal volume is the standard of ventilatory care for patients with ARDS. The current focus, however, has shifted to the proper setting of positive end-expiratory pressure (PEEP). The whole lung pressure-volume (P/V) curve has been used to individualize setting proper PEEP in patients with ARDS, although the physiologic interpretation of the curve remains under debate. The purpose of this review is to present the pros and cons of using P/V curves to set PEEP in patients with ARDS. A systematic analysis of recent and relevant literature was conducted. It has been hypothesized that proper PEEP can be determined by identifying P/V curve inflection points. Acquiring a dynamic curve presents the key to the curve's bedside application. The lower inflection point of the inflation limb has been shown to be the point of massive alveolar recruitment and therefore an option for setting PEEP. However, it is becoming widely accepted that the upper inflection point (UIP) of the deflation limb of the P/V curve represents the point of optimal PEEP. New methods used to identify optimal PEEP, including tomography and active compliance measurements, are currently being investigated. In conclusion, we believe that the most promising method for determining proper PEEP settings is use of the UIP of the deflation limb. However, tomography and dynamic compliance may offer superior bedside availability.
Collapse
|
22
|
Agarwal R, Srinivas R, Nath A, Jindal SK. Is the mortality higher in the pulmonary vs the extrapulmonary ARDS? A meta analysis. Chest 2007; 133:1463-1473. [PMID: 17989150 DOI: 10.1378/chest.07-2182] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
BACKGROUND AND AIM ARDS can occur from the following two pathogenetic pathways: a direct pulmonary injury (ARDSp); and an indirect injury (ARDSexp). The predisposing clinical factor can influence the pathogenesis and clinical outcome of ARDS. This metaanalysis was aimed at evaluating whether there is any difference in mortality between the two groups. METHODS We searched the MEDLINE, EMBASE, and CINAHL databases for relevant studies published from 1987 to 2007, and included studies that have reported mortality in the two groups of ARDS. We calculated the odds ratio (OR) and 95% confidence interval (CI) to assess mortality in patients with ARDSp vs patients with ARDSexp and pooled the results using three different statistical models. RESULTS Our search yielded 34 studies. In all, the studies involved 4,311 patients with 2,330 patients in the ARDSp group and 1,981 patients in the ARDSexp group. The OR of mortality in ARDSp group compared to the ARDSexp group was 1.11 (95% CI, 0.88 to 1.39), as determined by the random-effects model; 1.04 (95% CI, 0.92 to 1.18), as determined by the fixed-effects model; and 1.04 (95% CI, 0.92 to 1.18), as determined by the exact method, indicating that mortality is similar in the two groups. The mortality was no different whether the studies were classified as prospective (OR, 1.15; 95% CI, 0.87 to 1.51) or retrospective (OR, 1.01; 95% CI, 0.61 to 1.69); small (OR, 1.11; 95% CI, 0.77 to 1.60) or large (OR, 1.1; 95% CI, 0.82 to 1.49); or observational (OR, 1.10; 95% CI, 0.82 to 1.49) or interventional (OR, 0.97; 95% CI, 0.79 to 1.19). There was methodological and statistical heterogeneity (I(2), 50.9%; 95% CI, 21.3 to 66.2%; chi(2) statistic, 67.22; p = 0.0004). CONCLUSIONS The results of this study suggest that there is no difference in mortality between these two groups. Further studies should focus on specific etiologies within the subgroups rather than focusing on the broader division of ARDSp and ARDSexp.
Collapse
Affiliation(s)
- Ritesh Agarwal
- Department of Pulmonary Medicine, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Rajagopala Srinivas
- Department of Pulmonary Medicine, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Alok Nath
- Department of Pulmonary Medicine, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Surinder K Jindal
- Department of Pulmonary Medicine, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
| |
Collapse
|
23
|
Parker CM, Heyland DK, Groll D, Caeser M. Mechanism of injury influences quality of life in survivors of acute respiratory distress syndrome. Intensive Care Med 2006; 32:1895-900. [PMID: 16983550 DOI: 10.1007/s00134-006-0344-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2005] [Accepted: 07/24/2006] [Indexed: 01/11/2023]
Abstract
OBJECTIVE Growing evidence suggests that acute respiratory distress syndrome (ARDS) occurring as a consequence of primary (direct) lung injury differs from that resulting from secondary (indirect) lung injury in terms of radiographic appearance, response to interventions, and outcomes. We examined whether there are differences in quality of life (QOL) in survivors of ARDS attributable to the mechanism of underlying lung injury. DESIGN AND SETTING Prospective observational cohort study in 54 intensive care units in Canada and the United States. PATIENTS AND PARTICIPANTS Survivors of ARDS (n=73) were grouped according to underlying cause of ARDS (i.e., primary vs. secondary lung injury) and followed prospectively for 12months. MEASUREMENTS AND RESULTS QOL was assessed using the Medical Outcomes Study 36-item Short Form Health Survey (SF-36) and the St. George's Respiratory Questionnaire (SGRQ), and spirometry was performed at each outpatient follow-up visit. At 3months mortality and QOL outcomes were similar between the groups, but by 12months patients with primary lung injury had significantly better QOL scores in four of eight SF-36 domains and in two of three domains of the SGRQ. Differences were not attributable to duration of ICU or hospital length of stay, duration of mechanical ventilation, comorbidities prior to the index illness, or differences in spirometry during the follow-up period. CONCLUSIONS QOL in survivors of ARDS appears to be influenced by the mechanism of lung injury (primary vs. secondary), lending support to the concept that ARDS is a heterogeneous condition.
Collapse
Affiliation(s)
- Chris M Parker
- Department of Medicine, Queen's University, Kingston, Canada
| | | | | | | |
Collapse
|
24
|
Maggiore SM, Antonelli M. Expanding our horizons beyond the intensive care unit: does mechanism of lung injury influence the quality of life in ARDS survivors? Intensive Care Med 2006; 32:1683-5. [PMID: 16957902 DOI: 10.1007/s00134-006-0345-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2006] [Accepted: 07/24/2006] [Indexed: 10/24/2022]
|
25
|
Walder B, Fontao E, Totsch M, Morel DR. Time and tidal volume-dependent ventilator-induced lung injury in healthy rats. Eur J Anaesthesiol 2005; 22:785-94. [PMID: 16211751 DOI: 10.1017/s0265021505001304] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND OBJECTIVE We evaluated the effect of duration of mechanical ventilation with different tidal volumes (VT) on ventilator-induced lung injury in healthy rats. METHODS Anaesthetized rats were ventilated with VT between 9 and 45 mL kg[-1] for 1 or 7 h with a positive end-expiratory pressure of 2.5 cmH2O. RESULTS After 1 h, rats ventilated even with the highest applied VT (36 and 45 mL kg[minus sign]1, resulting in average peak airway pressures of 30 +/-3 and 37 +/- 4 cmH2O), had no detectable alterations in dynamic or static lung mechanics, gas exchange or pulmonary permeability, but a moderate degree of lung inflammation (neutrophil accumulation in broncho-alveolar lavage) observed in all groups. In contrast, after 3 h of ventilation, rats ventilated with the highest VT (36 and 45 mL kg[minus sign]1) died from progressive circulatory failure and high-permeability pulmonary oedema, manifested by hypoxaemia, an increased alveolar-arterial protein concentration ratio and a reduced static lung compliance (mortality rate at 7 h, 62.5% and 100%). Animals with lower VT all survived and presented no changes in the measured variables. CONCLUSION These results in normal rats demonstrate the preponderant effect of the duration (>3 h) of 'aggressive' ventilation and the cut-off value of the level of VT applied (>27 mL kg[minus sign]1).
Collapse
Affiliation(s)
- B Walder
- University Hospitals of Geneva, Division of Anaesthiological Investigations, Geneva, Switzerland.
| | | | | | | |
Collapse
|
26
|
Gattinoni L, Eleonora C, Caironi P. Monitoring of pulmonary mechanics in acute respiratory distress syndrome to titrate therapy. Curr Opin Crit Care 2005; 11:252-8. [PMID: 15928475 DOI: 10.1097/01.ccx.0000160773.43122.35] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
PURPOSE OF REVIEW This paper reviews recent findings regarding the respiratory mechanics during acute respiratory distress syndrome as a tool for tailoring its ventilatory management. RECENT FINDINGS The pressure-volume curve has been used for many years as a descriptor of the respiratory mechanics in patients affected by acute respiratory distress syndrome. The use of the sigmoidal equation introduced by Venegas for the analysis of the pressure-volume curve seems to be the most rigorous mathematical approach to assessing lung mechanics. Increasing attention has been focused on the deflation limb for titration of positive end-expiratory pressure. Based on physiologic reasoning, a novel parameter, the stress index, has been proposed for tailoring a safe mechanical ventilation, although its clinical impact has still to be proved. Evidence has confirmed that a variety of underlying pathologies may lead to acute respiratory distress syndrome, making unrealistic any attempt to unify the ventilatory approach. Although extensively proposed to tailor mechanical ventilation during acute respiratory distress syndrome, there is no evidence that the pressure-volume curve may be useful in setting a lung-protective strategy in the presence of different potentials for recruitment. SUMMARY The Venegas approach should be the standard analysis of pressure-volume curves. In any patient, the potential for recruitment should be assessed, as a basis for tailoring the most effective mechanical ventilation. Further studies are needed to clarify the potential use of the pressure-volume curve to guide a lung-protective ventilatory strategy.
Collapse
Affiliation(s)
- Luciano Gattinoni
- Istituto di Anestesia e Rianimazione, Ospedale Maggiore di Milano-IRCCS, Università degli Studi di Milano, Milano, Italy.
| | | | | |
Collapse
|
27
|
Rocco PRM, Zin WA. Pulmonary and extrapulmonary acute respiratory distress syndrome: are they different? Curr Opin Crit Care 2005; 11:10-7. [PMID: 15659940 DOI: 10.1097/00075198-200502000-00003] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
PURPOSE OF REVIEW Acute respiratory distress syndrome has been considered a morphologic and functional expression of lung injury caused by a variety of insults. Two distinct forms of acute respiratory distress syndrome/acute lung injury are described, because there are differences between pulmonary acute respiratory distress syndrome (direct effects on lung cells) and extrapulmonary acute respiratory distress syndrome (reflecting lung involvement in a more distant systemic inflammatory response). This article will focus on the differences in lung histology and morphology, respiratory mechanics, and response to ventilatory strategies and pharmacologic therapies in pulmonary and extrapulmonary acute respiratory distress syndrome. RECENT FINDINGS Many researchers recognize that experimental pulmonary and extrapulmonary acute respiratory distress syndrome are not identical. In addition, clinical studies have described the detection of differences radiographically, functionally, and by analysis of the responses to therapeutic interventions (ventilatory strategies, positive end-expiratory pressure, prone position, drugs). However, there are contradictions among the different studies addressing these issues, which could be attributed to the fact that the distinction between pulmonary and extrapulmonary acute respiratory distress syndrome is not always clear and simple. Furthermore, there may be frequent overlapping in pathogenetic mechanisms and morphologic alterations. SUMMARY The understanding of acute respiratory distress syndrome needs to take into account its origin. If each pathogenetic mechanism were to be considered, clinical management would be more precise, and probably the outcome could include real amelioration.
Collapse
Affiliation(s)
- Patricia R M Rocco
- Laboratory of Pulmonary Investigation, Carlos Chagas Filho Biophysics Institute, Federal University of Rio de Janeiro, Centro de Ciências da Saúde, Rio de Janeiro, Brazil
| | | |
Collapse
|
28
|
Markhorst DG, Jansen JRC, van Vught AJ, van Genderingen HR. Breath-to-breath analysis of abdominal and rib cage motion in surfactant-depleted piglets during high-frequency oscillatory ventilation. Intensive Care Med 2005; 31:424-30. [PMID: 15660244 DOI: 10.1007/s00134-004-2535-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2004] [Accepted: 12/08/2004] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To assess the value of monitoring abdominal and rib cage tidal displacement as an indicator of optimal mean airway pressure (Paw) during high-frequency oscillatory ventilation (HFOV). DESIGN AND SETTING Prospective observational study in a university research laboratory. ANIMALS Eight piglets weighing 12.0+/-0.5 kg, surfactant depleted by lung lavage. INTERVENTIONS Compliance of the respiratory system (C(rs)) was calculated from a quasistatic pressure volume loop. After initiation of HFOV lung volume was recruited by increasing Paw to 40 cmH(2)O. Then mean Paw was decreased in steps until PaO(2)/FIO(2) was below 100 mmHg. Proximal pressure amplitude remained constant. MEASUREMENTS AND RESULTS Abdominal and rib cage tidal displacement was determined using respiratory inductive plethysmography. During HFOV there was maximum in tidal volume (Vt) in seven of eight piglets. At maximal mean Paw abdominal and rib cage displacement were in phase. Phase difference between abdominal and rib cage displacement increased to a maximum of 178+/-28 degrees at minimum mean Paw. A minimum in abdominal displacement and a maximum of Vt was found near the optimal mean Paw, defined as the lowest mean Paw where shunt fraction is below 0.1. CONCLUSIONS During HFOV abdominal and rib cage displacement displayed mean Paw dependent asynchrony. Maximal Vt and minimal abdominal displacement coincided with optimal C(rs), oxygenation, and ventilation, suggesting potential clinical relevance of monitoring Vt and abdominal displacement during HFOV.
Collapse
Affiliation(s)
- Dick G Markhorst
- Pediatric ICU, Department of Pediatrics, Vrije Universiteit Medical Centre, Amsterdam, The Netherlands.
| | | | | | | |
Collapse
|
29
|
Albaiceta GM, Taboada F, Parra D, Luyando LH, Calvo J, Menendez R, Otero J. Tomographic Study of the Inflection Points of the Pressure–Volume Curve in Acute Lung Injury. Am J Respir Crit Care Med 2004; 170:1066-72. [PMID: 15317670 DOI: 10.1164/rccm.200312-1644oc] [Citation(s) in RCA: 72] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
The inflection points of the pressure-volume curve have been used for setting mechanical ventilation in patients with acute lung injury. However, the lung status at these points has never been specifically addressed. In 12 patients with early lung injury we traced both limbs of the pressure-volume curve by means of a stepwise change in airway pressure, and a computed tomography (CT) scan slice was obtained for every pressure level. Although aeration (increase in normally aerated lung) and recruitment (decrease in nonaerated lung) were parallel and continuous along the pressure axis during inflation, loss of aeration and derecruitment were only significant at pressures below the point of maximum curvature on the deflation limb of the pressure-volume curve. This point was related to a higher amount of normally aerated tissue and a lower amount of nonaerated tissue when compared with the lower inflection point on both limbs of the curve. Aeration at the inflection points was similar in lung injury from pulmonary or extrapulmonary origin. There were no significant changes in hyperinflated lung tissue. These results support the use of the deflation limb of the pressure-volume curve for positive end-expiratory pressure setting in patients with acute lung injury.
Collapse
Affiliation(s)
- Guillermo M Albaiceta
- Department of Intensive Medicine, Hospital Universitario Central de Asturias, Oveido, Spain.
| | | | | | | | | | | | | |
Collapse
|
30
|
Gattinoni L, Carlesso E, Valenza F, Chiumello D, Caspani ML. Acute respiratory distress syndrome, the critical care paradigm: what we learned and what we forgot. Curr Opin Crit Care 2004; 10:272-8. [PMID: 15258499 DOI: 10.1097/01.ccx.0000135511.75998.22] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
In the last several years, we definitely learned that the acute respiratory distress syndrome lung is small, nonhomogeneous, and that mechanical ventilation in this baby lung may cause physical damage as well as inflammatory reaction. The clinical benefit of the gentle lung treatment, based on a decrease of global/regional stress and strain into the lung, has been finally proved. However, we forgot the importance of lung perfusion and its distribution in this syndrome and, besides a low tidal volume, we still do not know how to handle the other variables of mechanical ventilation. Measurements of variables as transpulmonary pressure and end expiratory lung volume, for a rational setting of mechanical ventilation, should be introduced in routine clinical practice.
Collapse
Affiliation(s)
- Luciano Gattinoni
- Istituto di Anestesia e Rianimazione, Universita' degli Studi di Milano, Ospedale Policlinico IRCCS, Milano, Italy.
| | | | | | | | | |
Collapse
|
31
|
Abraham E, Andrews P, Antonelli M, Brochard L, Brun-Buisson C, Dobb G, Fagon JY, Groeneveld J, Mancebo J, Metnitz P, Nava S, Pinsky M, Radermacher P, Ranieri M, Richard C, Tasker R, Vallet B. Year in review in Intensive Care Medicine-2003. Part 1: Respiratory failure, infection and sepsis. Intensive Care Med 2004; 30:1017-31. [PMID: 15170528 DOI: 10.1007/s00134-004-2321-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/28/2004] [Indexed: 11/25/2022]
Affiliation(s)
- Edward Abraham
- Department of Medicine, Division of Pulmonary and Critical Care Medicine, University of Colorado Health Sciences Center, Denver, CO, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
32
|
Accuracy of Respiratory Inductive Plethysmography in Estimating Lung Volume Changes: The authors reply. Crit Care Med 2004. [DOI: 10.1097/01.ccm.0000126382.59958.b3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|