1
|
Ettinger M, Tuecking LR, Savov P, Windhagen H. Higher satisfaction and function scores in restricted kinematic alignment versus mechanical alignment with medial pivot design total knee arthroplasty: A prospective randomised controlled trial. Knee Surg Sports Traumatol Arthrosc 2024; 32:1275-1286. [PMID: 38501253 DOI: 10.1002/ksa.12143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2023] [Revised: 01/28/2024] [Accepted: 02/04/2024] [Indexed: 03/20/2024]
Abstract
PURPOSE Restricted kinematic alignment (rKA) in total knee arthroplasty (TKA) and medial pivot (MP) knee designs already showed superior outcomes in independent comparative studies. The objective of this study was to assess whether rKA with MP TKA provides better clinical and functional outcomes compared to mechanical alignment (MA) with MP TKA. METHODS This is a randomised, parallel two group study involving a total of 98 patients with end-stage knee osteoarthritis. Patients were randomly allocated to either rKA or MA TKA procedures conducted with a MP prothesis using patient-specific instruments between 2017 and 2020. Final follow-up was at 2 years postoperatively. Demographic data and clinical and functional scores (Oxford knee score, knee society score [KSS], Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC], forgotten joint score [FJS]) were collected and compared preoperative, 1 year postoperative and 2 years postoperative. Coronal plane alignment of the knee and functional knee phenotype classification were recorded. RESULTS A total of 47 patients (rKA) and 51 patients (MA) were included in final analysis. Superior joint awareness scores (FJS) were found at 1 year postoperative for rKA (62.2 vs. 52.4, p = 0.04). KSS subscores (expectation score, satisfaction score) improved with rKA with significant differences at both 1 and 2 years postoperatively. Major differences between rKA and MA were found in subgroup analysis of varus and neutral CPAK phenotypes. Both 1 year and 2 years postoperatively, FJS was significantly better in KA compared with MA in varus CPAK phenotypes (63.1 vs. 44.9, p = 0.03; 71.1 vs. 46.0, p = 0.005). Further clinical and functional scores showed improvement in the varus CPAK phenotypes with predominantly significant improvement in the expectation and satisfaction KSS subscores. No significant differences were found in the comparison of rKA and MA in neutral CPAK phenotypes. CONCLUSION The rKA of MP TKA design shows superior patient satisfaction and self-reported function when compared to MA MP TKA. Furthermore, rKA MP TKA shows superior joint awareness at early postoperative stage. The most important clinical relevance of this study is the clear superiority of rKA in varus phenotypes. LEVEL OF EVIDENCE Level II.
Collapse
Affiliation(s)
- Max Ettinger
- Department of Orthopaedic Surgery, Hannover Medical School, Diakovere Annastift, Hannover, Germany
| | - Lare-Rene Tuecking
- Department of Orthopaedic Surgery, Hannover Medical School, Diakovere Annastift, Hannover, Germany
| | - Peter Savov
- Department of Orthopaedic Surgery, Hannover Medical School, Diakovere Annastift, Hannover, Germany
| | - Henning Windhagen
- Department of Orthopaedic Surgery, Hannover Medical School, Diakovere Annastift, Hannover, Germany
| |
Collapse
|
2
|
Lee SS, Seo MK, Kim IS, Moon YW. Comparison of Survival Rate and Outcomes Between Conventional and Navigation-Assisted Primary Total Knee Arthroplasty in Severe Varus Knees: A Minimum 10-Year Follow-Up. J Arthroplasty 2022; 37:2164-2170. [PMID: 35618215 DOI: 10.1016/j.arth.2022.05.038] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Revised: 05/11/2022] [Accepted: 05/17/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND This study aimed to compare the long-term clinical and radiographic outcomes and survival rates between navigation-assisted (NAV) total knee arthroplasty (TKA) and conventional (CON) TKA in patients with preoperative severe varus deformity. METHODS From January 2005 to December 2011, 152 TKAs and 62 TKAs with preoperative hip-knee-ankle (HKA) angles more than 15° were enrolled in the CON-TKA and NAV-TKA group with 135.7 months follow-up. Clinical outcomes (Western Ontario and McMaster University Osteoarthritis Index and Knee Society Scores), radiographic outcomes (HKA, α, β, γ, and δ angles), and survivorship were compared between the groups. RESULTS The mean value of radiographic outcomes was not statistically different; however, outliers of the HKA angle were significantly higher in the CON-TKA group (18.4% versus 8.1%, P = .04). However, long-term clinical outcomes were similar between both groups. The cumulative survival rate was 96.1% in the CON-TKA group and 96.8% in the NAV-TKA group, with no difference between the groups (P = .962). CONCLUSION NAV-TKA showed fewer outliers in the HKA angle for severe preoperative varus deformity compared with CON-TKA. The long-term clinical outcomes and survival rates were similar between the 2 techniques. A survival rate of more than 96% was observed in both groups. STUDY DESIGN Level III, retrospective comparative study.
Collapse
Affiliation(s)
- Sung-Sahn Lee
- Department of Orthopedic Surgery, Ilsan Paik Hospital, Inje University School of Medicine, Goyangsi, Gyeonggido, South Korea
| | - Min Kyu Seo
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Il Su Kim
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Young-Wan Moon
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| |
Collapse
|
3
|
Navigated and Robot-Assisted Technology in Total Knee Arthroplasty: Do Outcome Differences Achieve Minimal Clinically Important Difference? J Arthroplasty 2022; 37:1562-1569. [PMID: 35367335 DOI: 10.1016/j.arth.2022.03.075] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2022] [Revised: 02/25/2022] [Accepted: 03/25/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND In total knee arthroplasty (TKA), computer-assisted navigation (N-TKA) and robotic-assisted methods (RA-TKA) are intended to increase precision of mechanical and component alignment. However, the clinical significance of published patient-reported outcome measure (PROM) differences in comparison to conventional TKA (C-TKA) is unknown. METHODS A systematic review was performed to identify all studies reporting perioperative PROMs for either primary N-TKA or RA-TKA with a C-TKA comparison cohort with a minimum 1-year follow-up. Relative improvements in PROMs for the two cohorts were compared to published minimal clinically important difference (MCID) values. RESULTS After systematic review, 21 studies (N = 3,214) reporting on N-TKA and eight studies (N = 1,529) reporting on RA-TKA met inclusion criteria. Eighteen of 20 studies (90%) reported improved radiographic outcomes with N-TKA relative to C-TKA; five of five studies reported improved radiographic outcomes with RA-TKA relative to C-TKA. Five of 21 studies (24%) reported statistically significant greater improvements in clinical PROMs for N-TKA relative to C-TKA, whereas only two (10%) achieved clinical significance relative to MCID on a secondary analysis. One of 8 studies (13%) reported statistically significant greater improvements in PROMs for RA-TKA relative to C-TKA, whereas none achieved clinical significance relative to MCID on a secondary analysis. No studies reported a significant difference in revision rates. CONCLUSION While most studies comparing RA-TKA and N-TKA with C-TKA demonstrate improved radiographic alignment outcomes, a minority of studies reported PROM differences that achieve clinical significance. Future studies should report data and be interpreted in the context of clinical significance to establish patient and surgeon expectations for emerging technologies.
Collapse
|
4
|
Similar outcomes in computer-assisted and conventional total knee arthroplasty: ten-year results of a prospective randomized study. BMC Musculoskelet Disord 2021; 22:707. [PMID: 34407776 PMCID: PMC8371882 DOI: 10.1186/s12891-021-04556-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Accepted: 07/12/2021] [Indexed: 11/16/2022] Open
Abstract
Background Computer-assisted navigation (CAS) was developed to improve the surgical accuracy and precision. Many studies demonstrated better alignment in the coronal plane in CAS TKA compared to conventional technique. The influence on the functional outcome is still unclear. Only few studies report long-term results of CAS TKA. This study was initiated to investigate 10-year patient-reported outcome of CAS and conventional TKA. Methods From initially 80 patients of a randomized study of CAS and conventional TKA a total of 50 patients could be evaluated at the 10-year follow-up. The Knee Society Score and EuroQuol Questionnaire were assessed. For all patients a competing risk analysis for revision was performed. Results The patient-reported outcome measures demonstrated similar values for both groups. The 10-year risk for revision was 2.5% for conventional TKA and 7.5% for CAS TKA (p=0.237). Conclusions There was no difference between CAS and conventional TKA with regard to patient-reported outcome and revision risk ten years after surgery. Trial registration This study was registered at clinicaltrials.gov on 11/30/2009, ID: NCT01022099.
Collapse
|
5
|
Buchlak QD, Clair J, Esmaili N, Barmare A, Chandrasekaran S. Clinical outcomes associated with robotic and computer-navigated total knee arthroplasty: a machine learning-augmented systematic review. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2021; 32:915-931. [PMID: 34173066 DOI: 10.1007/s00590-021-03059-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Accepted: 06/14/2021] [Indexed: 10/21/2022]
Abstract
BACKGROUND Robotic (RTKA) and computer-navigated total knee arthroplasty (CNTKA) are increasingly replacing manual techniques in orthopaedic surgery. This systematic review compared clinical outcomes associated with RTKA and CNTKA and investigated the utility of natural language processing (NLP) for the literature synthesis. METHODS A comprehensive search strategy was implemented. Results of included studies were combined and analysed. A transfer learning approach was applied to train deep NLP classifiers (BERT, RoBERTa and XLNet), with cross-validation, to partially automate the systematic review process. RESULTS 52 studies were included, comprising 5,067 RTKA and 2,108 CNTKA. Complication rates were 0-22% and 0-16% and surgical time was 70-116 and 77-102 min for RTKA and CNTKA, respectively. Technical failures were more commonly associated with RTKA (8%) than CNTKA (2-4%). Patient satisfaction was equivalent (94%). RTKA was associated with a higher likelihood of achieving target alignment, less femoral notching, shorter operative time and shorter length of stay. NLP models demonstrated moderate performance (AUC = 0.65-0.68). CONCLUSIONS RTKA and CNTKA appear to be associated with similarly positive clinical outcomes. Further work is required to determine whether the two techniques differ significantly with regard to specific outcome measures. NLP shows promise for facilitating the systematic review process.
Collapse
Affiliation(s)
- Quinlan D Buchlak
- School of Medicine, The University of Notre Dame Australia, Sydney, NSW, Australia.
| | - Joe Clair
- Department of Orthopaedics, Werribee Mercy Hospital, Melbourne, VIC, Australia
| | - Nazanin Esmaili
- School of Medicine, The University of Notre Dame Australia, Sydney, NSW, Australia.,Faculty of Engineering and Information Technology, University of Technology Sydney, Ultimo, NSW, Australia
| | - Arshad Barmare
- School of Medicine, The University of Notre Dame Australia, Sydney, NSW, Australia.,Department of Orthopaedics, Werribee Mercy Hospital, Melbourne, VIC, Australia
| | - Siva Chandrasekaran
- Department of Orthopaedics, Werribee Mercy Hospital, Melbourne, VIC, Australia
| |
Collapse
|
6
|
Tsuda K, Shibuya T, Okamoto N, Shiigi E, Shirakawa N, Hosaka K, Akagi R, Ohdera T. Can accuracy with the iASSIST navigation be confirmed by assessment? A multi-center prospective randomized controlled trial with independent three-dimensional image assessment. Knee 2021; 30:344-352. [PMID: 34038856 DOI: 10.1016/j.knee.2021.04.019] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/26/2020] [Revised: 03/17/2021] [Accepted: 04/22/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND iASSIST is one of the novel accelerometer-based navigation systems for total knee arthroplasty (TKA). Although the accuracy of iASSIST compared with conventional instruments has been reported, such evaluations were performed on two-dimensional (2D) images (X-rays). This multi-center prospective randomized controlled trial aimed to assess component positioning between TKA with and without iASSIST by 3D image assessment, and to clarify whether the iASSIST provides any benefit with regard to alignment accuracy. METHODS Eighty-three knees with primary knee osteoarthritis were enrolled in this study. iASSIST was used for distal femoral and proximal tibial resection in 42 knees (iA group) and a conventional guide was used in 41 knees (CONV group). At 6 months postoperatively, component alignment was evaluated with 3D images by the independent orthopaedic surgeons, and surgical parameters, range of motion and clinical outcomes were examined. RESULTS The rate of knees who have the alignment within 3° of neutral compared with the iA group and CONV group were 92.9% (39/42) vs. 87.8% (36/41) for femur and 76.2% (32/42) vs. 56.1% (23/41) for tibia in the coronal plane, respectively, whereas in the sagittal plane, the rate was 85.7% (36/42) vs. 58.5% (24/41) for femur and 83.3% (35/42) vs. 78.0% (32/41) for tibia, respectively. Compared with the CONV group, the iA group had a significantly improved femoral alignment in the sagittal plane (P = 0.006). There were no clinical or patient-reported differences at 6 months postoperatively. CONCLUSIONS The iASSIST provides technically high accuracy in femoral resection at TKA compared with a conventional procedure.
Collapse
Affiliation(s)
- Kosuke Tsuda
- Department of Orthopaedic Surgery, Sumitomo Hospital, Osaka, Japan.
| | - Takaaki Shibuya
- Department of Orthopaedic Surgery, Sumitomo Hospital, Osaka, Japan
| | - Nobukazu Okamoto
- Department of Orthopaedic Surgery, Kumamoto University Hospital, Kumamoto, Japan
| | - Eiichi Shiigi
- Department of Orthopaedic Surgery, Yamaguchi Prefectural Grand Medical Center, Yamaguchi, Japan
| | - Nobuyuki Shirakawa
- Department of Orthopaedic Surgery, Japanese Red Cross Medical Center, Tokyo, Japan
| | - Kunihiro Hosaka
- Department of Orthopaedic Surgery, Nihon University Itabashi Hospital, Tokyo, Japan
| | - Ryuichiro Akagi
- Department of Orthopaedic Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan
| | - Toshihiro Ohdera
- Department of Orthopaedic Surgery, Fukuoka Orthopedic Hospital, Fukuoka, Japan
| |
Collapse
|
7
|
Chin BZ, Seck VMH, Syn NLX, Wee IJY, Tan SSH, O'Neill GK. Computer-Navigated versus Conventional Total Knee Arthroplasty: A Meta-Analysis of Functional Outcomes from Level I and II Randomized Controlled Trials. J Knee Surg 2021; 34:648-658. [PMID: 31683347 DOI: 10.1055/s-0039-1700494] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The main purpose of this article is to provide an up-to-date systematic review and meta-analysis comparing functional outcomes of total knee arthroplasty using either computer navigation (NAV-TKA) or conventional methods (CON-TKA) from the latest assemblage of evidence. This study was conducted according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses and Meta-Analysis of Observational Studies in Epidemiology guidelines. All Level I and II randomized controlled trials (RCTs) in PubMed, EMBASE, and Cochrane that compared functional outcomes after NAV- and CON-TKA were included in the review. Selected end points for random effects, pairwise meta-analysis included Knee Society Knee Score (KSKS), KS Function Score (KSFS), KS Total Score (KSTS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and range of motion at three arbitrary follow-up times. A total of 24 prospective RCTs comprising 3,778 knees were included from the initial search. At long-term follow-up (>5 years), NAV-TKA exhibited significantly better raw KSKS (p = 0.001) (low-quality evidence), contrary to CON-TKA, which reflected significantly better raw KSTS (p = 0.004) (high-quality evidence). While change scores (KSKS, WOMAC) from preoperative values favor CON-TKA at short-term (<6 months) and medium-term follow-up (6-60 months), long-term follow-up change scores in KSKS suggest the superiority of NAV-TKA over CON-TKA (p = 0.02) (very low-quality evidence). Overall, sizeable dispersion of nonstatistically significant functional outcomes in the medium term was observed to eventually converge in the long term, with less differences in functional outcome scores between the two treatment methods in short- and long-term follow-up. While raw functional outcome scores reflect no differences between NAV and CON-TKA, long-term follow-up change scores in KSKS suggest superiority of NAV-TKA over its conventional counterpart. Prospective studies with larger power are required to support the pattern of diminishing differences in functional outcome scores from medium- to long-term follow-up between the two modalities.
Collapse
Affiliation(s)
- Brian Zhaojie Chin
- University Orthopaedics, Hand and Reconstructive Microsurgical Cluster, National University Health System, Singapore
| | - Victor Mun Hin Seck
- University Orthopaedics, Hand and Reconstructive Microsurgical Cluster, National University Health System, Singapore
| | - Nicholas Li-Xun Syn
- University Orthopaedics, Hand and Reconstructive Microsurgical Cluster, National University Health System, Singapore
| | - Ian Jun Yan Wee
- University Orthopaedics, Hand and Reconstructive Microsurgical Cluster, National University Health System, Singapore
| | - Sharon Si Heng Tan
- University Orthopaedics, Hand and Reconstructive Microsurgical Cluster, National University Health System, Singapore
| | - Gavin Kane O'Neill
- University Orthopaedics, Hand and Reconstructive Microsurgical Cluster, National University Health System, Singapore
| |
Collapse
|
8
|
Stübig T, Windhagen H, Krettek C, Ettinger M. Computer-Assisted Orthopedic and Trauma Surgery. DEUTSCHES ARZTEBLATT INTERNATIONAL 2020; 117:793-800. [PMID: 33549155 PMCID: PMC7947640 DOI: 10.3238/arztebl.2020.0793] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Revised: 04/06/2020] [Accepted: 08/24/2020] [Indexed: 11/27/2022]
Abstract
BACKGROUND There are many ways in which computer-assisted orthopedic and trauma surgery (CAOS) procedures can help surgeons to plan and execute an intervention. METHODS This study is based on data derived from a selective search of the literature in the PubMed database, supported by a Google Scholar search. RESULTS For most applications the evidence is weak. In no sector did the use of computer-assisted surgery yield any relevant clinical or functional improvement. In trauma surgery, 3D-navigated sacroiliac screw fixation has become clinically established for the treatment of pelvic fractures. One randomized controlled trial showed a reduction in the rate of screw misplacement: 0% with 3D navigation versus 20.4% with the conventional procedure und 16.6% with 2D navigation. Moreover, navigation-assisted pedicle screw stabilization lowers the misplacement rate. In joint replacements, the long-term results showed no difference in respect of clinical/functional scores, the time for which the implant remained in place, or aseptic loosening. CONCLUSION Computer-assisted procedures can improve the precision of certain surgical interventions. Particularly in joint replacement and spinal surgery, the research is moving away from navigation in the direction of robotic procedures. Future studies should place greater emphasis on clinical and functional results.
Collapse
Affiliation(s)
- Timo Stübig
- Department of Traumatology, Hannover Medical School
| | - Henning Windhagen
- Department of Orthopedic Surgery, Hannover Medical School, Annastift
| | | | - Max Ettinger
- Department of Orthopedic Surgery, Hannover Medical School, Annastift
| |
Collapse
|
9
|
Gao J, Dong S, Li JJ, Ge L, Xing D, Lin J. New technology-based assistive techniques in total knee arthroplasty: A Bayesian network meta-analysis and systematic review. Int J Med Robot 2020; 17:e2189. [PMID: 33108058 DOI: 10.1002/rcs.2189] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Revised: 10/18/2020] [Accepted: 10/22/2020] [Indexed: 02/05/2023]
Abstract
BACKGROUND The radiological and clinical efficiency among robot-assisted surgery (RAS), computer-assisted navigation system (CAS) and conventional (CON) total knee arthroplasty (TKA) remains controversial. METHODS Bayesian network meta-analysis (NMA) and systematic review were performed to investigate radiological and clinical efficiency respectively. The certainty of the evidence was evaluated using GRADE and CERQual tool. RESULTS Thirty-four RCTs (7289 patients and 7424 knees) were included. The NMA showed that RAS-TKA had the highest probability for mechanical axis restoration (odds ratio for RAS vs. CAS 3.79, CrI 1.14 to 20.54, very low certainty), followed by CAS-TKA (odds ratio for CAS vs. CON 2.55, CrI 1.67 to 4.01, very low certainty) and then CON-TKA, without significant differences in other radiological parameters. No differences were found in clinical outcomes after qualitative systematic review (overall low certainty). CONCLUSIONS Technology-based assistive techniques (CAS and RAS) may surpass the CON-TKA, when considering higher radiological accuracy and comparable clinical outcomes. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Jiaxiang Gao
- Arthritis Clinic & Research Center, Peking University People's Hospital, Peking University, Beijing, China
- Arthritis Institute, Peking University, Beijing, China
| | - Shengjie Dong
- Orthopedic department, Yantaishan Hospital, Yantai, Shandong, China
| | - Jiao Jiao Li
- Kolling Institute, University of Sydney, Sydney, NSW, 2006, Australia
| | - Long Ge
- Evidence Based Social Science Research Center, School of Public Health, Lanzhou University, Gansu, China
- Department of Health Research Methods, Evidence and Impact, McMaster University, Hamilton, Canada
| | - Dan Xing
- Arthritis Clinic & Research Center, Peking University People's Hospital, Peking University, Beijing, China
- Arthritis Institute, Peking University, Beijing, China
| | - Jianhao Lin
- Arthritis Clinic & Research Center, Peking University People's Hospital, Peking University, Beijing, China
- Arthritis Institute, Peking University, Beijing, China
| |
Collapse
|
10
|
Lee DY, Park YJ, Hwang SC, Park JS, Kang DG. No differences in mid- to long-term outcomes of computer-assisted navigation versus conventional total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2020; 28:3183-3192. [PMID: 31784782 DOI: 10.1007/s00167-019-05808-5] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2019] [Accepted: 11/19/2019] [Indexed: 11/26/2022]
Abstract
PURPOSE Accurate implant position in total knee arthroplasty (TKA) can potentially lead to better long-term functional outcomes and implant survival. Recent studies on whether better clinical results could be obtained from computer-navigated or conventional TKA were inconclusive. In addition, recent reviews only included short-term follow-up studies without performing quantitative mid- to long-term follow-up analysis. Thus, the purpose of the present study was to perform a meta-analysis comparing mid- to long-term clinical outcomes (such as knee scoring and functional results) and radiological outcomes (such as normal alignment of the limb axis or component) between computer-navigated TKA and conventional TKA to determine which method of TKA could obtain better clinical and radiological results. METHODS MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials (CENTRAL), Web of Science, and SCOPUS electronic databases were searched for relevant articles published through August 2018 that compared outcomes of computer-navigated TKA and conventional TKA. Data search, extraction, analysis, and quality assessment were performed according to the Cochrane Collaboration guidelines. Clinical and radiological outcomes of both techniques were evaluated using various outcome measures. RESULTS Seven randomized controlled trials were included. Based on Knee Society Scores, the Western Ontario and McMaster Universities Osteoarthritis Index, pain, and range of motion, there were no significant differences in clinical outcomes between the two techniques. Based on outliers from the normal axis, outliers of femoral components in the coronal plane, and outliers of tibial components in the coronal plane, radiologic outcomes showed no significant differences between the two techniques either. CONCLUSIONS The present study revealed that there were no significant differences in clinical or radiological outcomes between computer-navigated TKA and conventional TKA. It remains unclear which TKA technique yields better results in terms of mid- to long-term clinical and radiological outcomes. LEVEL OF EVIDENCE I.
Collapse
Affiliation(s)
| | - Young-Jin Park
- Department of Orthopaedic Surgery and Institute of Health Science, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Republic of Korea
| | - Sun-Chul Hwang
- Department of Orthopaedic Surgery and Institute of Health Science, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Republic of Korea
| | - Jin-Sung Park
- Department of Orthopaedic Surgery and Institute of Health Science, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Republic of Korea
| | - Dong-Geun Kang
- Department of Orthopaedic Surgery and Institute of Health Science, Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital, Samjeongja-ro 11, Seongsan-gu, Changwon, 51472, Republic of Korea.
| |
Collapse
|
11
|
Sharma M, Dhanjani B, Bashir J, Anshu AK. Clinico-Radiological and Functional Results of the Navigated Gradius (Gradually Reducing Radius) Knee Prosthesis at Short to Mid-Term Follow-Up. Indian J Orthop 2020; 55:62-68. [PMID: 34122756 PMCID: PMC8149567 DOI: 10.1007/s43465-020-00266-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2020] [Accepted: 09/16/2020] [Indexed: 02/04/2023]
Abstract
BACKGROUND Navigated total knee replacements (TKR) have shown better knee function and quality of life. It also reduces revision rates. The aim of our study is to evaluate short to mid-term clinico-radiological and functional results, survival rate and complications of Gradius knee prosthesis implanted using computer navigation. METHODS We retrospectively reviewed 120 Gradius knee prosthesis, implanted in 68 patients (52 bilateral TKR and 16 unilateral TKR) and followed from Jan 2015 till Jan 2020. Pre-operative & post-operative radiographs, knee society scores (KSS), range of motion (ROM), deformity assessment and gait video recordings were done for all patients. RESULTS The mean follow-up was 3.8 years (minimum 2-5 years).The mean ROM was 2° (0-10) extension to 135° (128°-138°) flexion. The KSS pain score improved from mean of 38.3 (range 26-44) to 90.4 (mean 88-92). The KSS functional score improved from 36.2 (range 28-39) to 92.6 (range 86-94). All patients had excellent to good function during successive follow-ups. The coronal alignment improved from 8° varus to 0.3° varus. Sagittal alignment was corrected from 8° (4°-18°) preoperatively to 2° (0°-8°) postoperatively. CONCLUSION At mid-term our series outlines the better functional and radiological results of Gradius knee prosthesis using navigation as a tool. We recommend a prospective randomized controlled trials comparing navigated versus non-navigated for Gradius knee prosthesis with long-term follow-up.
Collapse
Affiliation(s)
- Mrinal Sharma
- grid.501415.40000 0004 1775 3981Department of Orthopedic Surgery, Asian Institute of Medical Sciences, Faridabad, Haryana India ,1203, Imperial Court Tower 2, Jaypee Greens Wish Town, Gautam Budh Nagar, Noida, Uttar Pradesh 201304 India
| | - Bharat Dhanjani
- grid.501415.40000 0004 1775 3981Department of Orthopedic Surgery, Asian Institute of Medical Sciences, Faridabad, Haryana India
| | - Jibran Bashir
- grid.501415.40000 0004 1775 3981Department of Orthopedic Surgery, Asian Institute of Medical Sciences, Faridabad, Haryana India
| | - Anshu Kumar Anshu
- grid.501415.40000 0004 1775 3981Department of Orthopedic Surgery, Asian Institute of Medical Sciences, Faridabad, Haryana India
| |
Collapse
|
12
|
Shatrov J, Parker D. Computer and robotic - assisted total knee arthroplasty: a review of outcomes. J Exp Orthop 2020; 7:70. [PMID: 32974864 PMCID: PMC7516005 DOI: 10.1186/s40634-020-00278-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Accepted: 08/17/2020] [Indexed: 01/10/2023] Open
Abstract
Background Total knee arthroplasty (TKA) is a successful treatment for tricompartmental knee arthritis. Computer navigation and robotic-assisted-surgery (RAS) have emerged as tools that aim to help plan and execute surgery with greater precision and consistency. We reviewed the most current literature to describe the historical background and outcomes compared to conventional TKA. Methods A review and synthesis of the literature comparing the patient reported outcomes (PROM’s) of RA TKA and computer-assisted (CA) TKA to conventional TKA was performed using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Results CAS TKA improves accuracy and consistency of implant position, and appears to provide a small improvement in PROMs and implant survival compared to conventional TKA. RTKA similarly improves implant accuracy compared to conventional techniques and early results suggest a similar small benefit in PROMs compared to conventional TKA. A strengthening trend is emerging showing CAS TKA has greatest benefit to implant survival in people under 65. RTKA survival analysis data is more limited and early results do not allow strong conclusions, however early trends are similar to CAS TKA. Conclusion Results for CAS-TKA show improvement in alignment, and early clinical outcomes have revealed promising results, with longer-term data and medium-term survival analysis recently emerging showing small benefits over conventional TKA. RTKA represents another phase of development. Early results show similar trends to that of CAS TKA with longer-term data still to come.
Collapse
Affiliation(s)
- Jobe Shatrov
- Royal North Shore Hospital, St Leonards, Australia. .,Sydney Orthopaedic Research Institute, Chatswood, Australia.
| | - David Parker
- Royal North Shore Hospital, St Leonards, Australia.,Sydney Orthopaedic Research Institute, Chatswood, Australia.,University of Sydney, Sydney, Australia
| |
Collapse
|
13
|
Jeremić DV, Massouh WM, Sivaloganathan S, Rosali AR, Haaker RG, Rivière C. Short-term follow-up of kinematically vs. mechanically aligned total knee arthroplasty with medial pivot components: A case-control study. Orthop Traumatol Surg Res 2020; 106:921-927. [PMID: 32522532 DOI: 10.1016/j.otsr.2020.04.005] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2019] [Revised: 03/29/2020] [Accepted: 04/07/2020] [Indexed: 02/03/2023]
Abstract
INTRODUCTION The kinematic alignment (KA) technique for total knee arthroplasty (TKA) and the medial pivot (MP) component design are two options promoting a physiologic prosthetic knee kinematics when used in combination that could improve TKA outcomes. Case-control study is initiated to compare the 1-year radio-clinical outcomes between kinematic alignment medial pivot total knee arthroplasty (KA MP-TKAs) and mechanical alignment medial pivot total knee arthroplasty (MA MP-TKA). Goal of a study was to answer the following questions: Do KA MP-TKAs patients have improved functional outcomes compared to MA MP-TKAs patients? (Q1); Do prosthetic knee and lower limb alignments differ between KA and MA patients (Q2)? And does kinematic implantation of MP TKA has higher risk of reoperations and revisions (Q3)? MATERIAL AND METHODS A case-control study was carried out to compare the 1-year clinical and radiographic outcomes between 24 consecutive KA-TKA patients and 24 matched MA-TKA patients. All patients had implantation with manual instruments and a cemented medial pivot TKA with excision of the PCL. All data were collected prospectively, and outcome scores were patient reported. RESULTS KA patients had superior values in Forgotten Joint Score (FJS) at 1-year (KA 77 vs. MA 51) (p=0.05) follow-up. After one year KA patients scored better in objective section of the new Knee Society Score (KSS) (p=0.02), and in sport section of the Knee Osteoarthritis Outcome Score (KOOS) (p=0.01). Eleven out of 24 patients (46%) in KA group and 7/24 patients (29%) in MA group had limb alignment out of 180°±3°, whereas 17/24 (70%) of KA patients, and 14/24 (58%) of MA patients had orientation of tibial component with more than 3° of varus. No reoperation or revision occurred in either group. DISCUSSION/CONCLUSION The KA of MP TKA design seems to have a good efficacy at early-term, with some 1-year functional performance higher to the ones from MA MP TKAs. Further research is needed to define if those early results will last over time. LEVEL OF EVIDENCE III, case-controlled study.
Collapse
Affiliation(s)
- Dragan V Jeremić
- Clinic for Orthopedic Surgery, St.-Vincenz Hospital, Brakel, Germany.
| | - Wissam M Massouh
- Clinic for Orthopedic Surgery, St.-Vincenz Hospital, Brakel, Germany
| | | | - Almeric R Rosali
- Clinic for Orthopedic Surgery, St.-Vincenz Hospital, Brakel, Germany
| | - Rolf G Haaker
- Clinic for Orthopedic Surgery, St.-Vincenz Hospital, Brakel, Germany
| | - Charles Rivière
- MSK Lab - Imperial College London, White City Campus, The Lister Hospital, Chelsea Bridge, London, UK; Centre de l'Arthrose, Bordeaux-Mérignac, France
| |
Collapse
|
14
|
Ayekoloye C, Nwangwu O, Alonge T. Computer Navigation-Assisted Knee Replacement Demonstrates Improved Outcome Compared with Conventional Knee Replacement at Mid-Term Follow-up: A Systematic Review and Meta-analysis. Indian J Orthop 2020; 54:757-766. [PMID: 33133398 PMCID: PMC7572977 DOI: 10.1007/s43465-020-00161-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Accepted: 05/29/2020] [Indexed: 02/04/2023]
Abstract
The study is a systematic review and meta-analysis of prospective randomised control studies and prospective cohort studies of mid-term functional outcome of total knee replacement undertaken using imageless computer navigation compared with conventional instrumented total knee replacement. The literature search strategy included a search of the electronic databases, visual scanning of reference lists, hand searching of key journals and conference proceedings, and abstracts, citations, and trial registers. In total, 440 papers were retrieved after removal of duplicates, and with further screening, 11 papers were included in the systematic review and 6 papers were considered appropriate for meta-analysis. Analysis of the data showed evidence of a modest improvement in functional outcome at mid-term follow-up with use of imageless computer navigation assistance compared with conventional instrumented total knee replacement with a total score point estimate of 3.36 confidence interval (CI) (- 0.583, 7.298), objective score point estimate of 1.45 CI (0.11, 2.799), and functional score point estimate of 2.4, CI (- 1.174, 5.977). The predominant risk of bias was from random allocation and attrition. There is evidence of a modest improvement in functional outcome with the use of imageless computer navigation assistance compared with conventional instrumented total knee replacement at mid-term follow-up.
Collapse
Affiliation(s)
| | - Osondu Nwangwu
- Department of Orthopaedics, Luton and Dunstable Hospital, Bedfordshire, UK
| | | |
Collapse
|
15
|
Petursson G, Fenstad AM, Gøthesen Ø, Dyrhovden GS, Hallan G, Röhrl SM, Aamodt A, Furnes O. Computer-Assisted Compared with Conventional Total Knee Replacement: A Multicenter Parallel-Group Randomized Controlled Trial. J Bone Joint Surg Am 2018; 100:1265-1274. [PMID: 30063588 DOI: 10.2106/jbjs.17.01338] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND We previously reported the short-term radiographic and functional results of a randomized controlled trial (RCT) comparing computer-assisted and conventionally performed total knee replacement. We currently report the 2-year clinical results from this trial. METHODS One hundred and ninety patients were randomly allocated to undergo either computer-assisted or conventional total knee replacement. One hundred and seventy-two patients were available for clinical evaluation at 2 years, and 167 (97%) of those answered all patient-reported outcome measures (PROMs), including the Knee Injury and Osteoarthritis Outcome Score (KOOS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Knee Society Score (KSS), visual analog scale (VAS), and EuroQol-5 Dimensions (EQ-5D). Patients and clinical evaluators were blinded to the method of surgery. Surgical outcome was assessed using the Outcome Measures in Rheumatology-Osteoarthritis Research Society International (OMERACT-OARSI) criteria to calculate responder rates, divided into high responders, moderate responders, and nonresponders. RESULTS The computer-assisted group had significantly more improvement than the conventional group in the mean scores for 2 subscales of the KOOS (7.4 for symptoms [p = 0.02] and 16.2 for sport and recreation [p < 0.01]) and in 1 subscale of the WOMAC (8.8 for stiffness [p = 0.03]).The computer-assisted group also had significantly more high responders (82.8%) than the conventional group (68.8%; p = 0.03) at 2 years, with the number needed to treat determined to be 8. CONCLUSIONS In this study, the use of computer navigation provided better pain relief and restored better function than the use of the conventional surgical technique at 2 years after total knee replacement. LEVEL OF EVIDENCE Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Gunnar Petursson
- Lovisenberg Diaconal Hospital, Oslo, Norway.,The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen, Norway
| | - Anne Marie Fenstad
- The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen, Norway
| | - Øystein Gøthesen
- The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen, Norway.,Department of Clinical Medicine, Faculty of Medicine, University of Bergen, Bergen, Norway.,Haugesund Sanitetsforenings Hospital for Rheumatic Diseases, Haugesund, Norway
| | - Gro Sævik Dyrhovden
- The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen, Norway.,Department of Clinical Medicine, Faculty of Medicine, University of Bergen, Bergen, Norway
| | - Geir Hallan
- Department of Clinical Medicine, Faculty of Medicine, University of Bergen, Bergen, Norway
| | - Stephan M Röhrl
- Department of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway
| | | | - Ove Furnes
- The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen, Norway.,Department of Clinical Medicine, Faculty of Medicine, University of Bergen, Bergen, Norway
| |
Collapse
|
16
|
Twelve-Year Follow-Up of Navigated Computer-Assisted Versus Conventional Total Knee Arthroplasty: A Prospective Randomized Comparative Trial. J Arthroplasty 2018; 33:1404-1411. [PMID: 29426792 DOI: 10.1016/j.arth.2017.12.012] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2017] [Revised: 11/10/2017] [Accepted: 12/12/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Navigated computer-assisted total knee arthroplasty (TKA) was introduced to expedite long-term survival based on improved postoperative implantation accuracy. However, long-term outcome data after 10 years or more are rare, even available meta-analyses show controversial study results. METHODS In a prospective randomized trial, 100 conventional TKAs (group CONV) were compared with 100 computer-assisted TKAs (group NAV) after a mean follow-up of 12 years postoperatively. A long-leg weight-bearing X-ray was performed for measuring mechanical axis of the limb, lateral distal femoral angle, and medial proximal tibial angle. Tibial slope, patella alpha angle, and radiolucent lines were also observed. Clinical investigation included evaluation of 4 different scores: Insall Knee Score, Western Ontario and MacMaster University Index score, Hospital for Special Surgery Knee Score, and visual analog scale. RESULTS Based on a follow-up rate of at least 75%, no difference in TKA survival was found 12 years postoperatively: 91.5% in group CONV vs 98.2% in group NAV (P = .181). Since 5-year follow-up, no additional TKA revision had been performed in both groups. Group CONV showed a nonsignificant higher inaccuracy of neutral lower limb axis (1.8° ± 1.4°) compared to group NAV (1.6° ± 1.7°, P = .700). All X-ray assessments were not significant different within both study groups (P ≥ .068). Clinical examination showed no differences in evaluations (P ≥ .204). All collected outcome score results were similar (P ≥ .222). CONCLUSION Twelve years postoperatively, no differences were found in terms of long-term survival, implantation accuracy, clinical outcome or score results.
Collapse
|
17
|
CORR Insights®: No Benefit of Computer-assisted TKA: 10-year Results of a Prospective Randomized Study. Clin Orthop Relat Res 2018. [PMID: 29529628 PMCID: PMC5919236 DOI: 10.1007/s11999.0000000000000094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
18
|
Abstract
BACKGROUND Previously published studies reported benefits of computer-assisted surgery (CAS) in terms of radiographic implant position in TKA, but whether these improvements result in clinically important survival differences or functional differences that a patient might perceive at a minimum 10-year followup remains largely unknown. QUESTIONS/PURPOSES We performed a prospective randomized trial and asked whether CAS (1) improved survival free from aseptic loosening; and (2) demonstrated any clear difference in patient-reported outcomes at latest followup using validated outcome measures at minimum 10-year followup. METHODS Between January 2004 and December 2005, 80 patients scheduled for TKA were randomly assigned either to the CAS group or to the conventional technique group by the Hospital Informatics Department. The patient inclusion criteria were age 20 to 80 years old, weight < 100 kg, and consent to receive a primary knee arthroplasty performed through a medial parapatellar approach by the senior author. The exclusion criteria were a history of prior knee surgery, TKA performed for a posttraumatic indication, or revision knee surgery. The first 80 patients meeting these criteria were included in the study. There were 21 women and 19 men and in each group; mean age was 66 years (range, 58-77 years), and mean body mass index was 27 ± 4 kg/m. An initial published study using this patient group investigated only differences regarding implant positioning in the coronal and sagittal planes. This is a secondary analysis of patients from the earlier study protocol at a minimum of 10-year followup with different endpoints. Kaplan-Meier survivorship was compared between groups, and functional patient-reported outcome measures (PROMs) were evaluated using the SF-12, Knee Injury and Osteoarthritis Outcome Score (KOOS), Forgotten Joint Score, and the new Knee Society Score. Those PROMs were not available at the time of the original randomized controlled trial and we therefore do not have baseline preoperative values demonstrating that our two groups were comparable. However, our groups were created using strict randomization and were similar in terms of demographic parameters and knee deformities. Our secondary analysis was not powered for survival analysis but had 80% power to detect a difference > 6 points on the SF-12 components and > 6 points out of 100 on the KOOS subscores (published minimal clinically important difference: 8 points) at the p < 0.05 level. RESULTS With the numbers available, there was no difference between the CAS group and the conventional TKA group in terms of survivorship free from aseptic loosening 10 years after TKA (97%, 95% confidence interval [CI], 95%-99% versus 97%, 95% CI, 95%-99%; p = 0.98). Investigation of the latest followup PROM scores showed no difference between SF-12 scores (respectively, for CAS and control patients, physical SF-12: 72 ± 12 versus 73 ± 13 mean difference 0, 95% CI -3 to 3, p = 0.9; mental SF-12: 75 ± 8 versus 73 ± 10, mean difference 2, 95% CI 0-4, p = 0.3) as well as for all KOOS subscores (all p > 0.1). Forgotten Joint Scores were similar in both groups with 83 ± 4 for CAS and 82 ± 5 for control patients (mean difference 1, 95% CI 0-2, p = 0.2). Finally, the new Knee Society Scores were not statistically different between groups with a mean objective score of 82 ± 13 for CAS patients versus 79 ± 12 for control patients (mean difference 2, 95% CI 0-5, p = 0.5) and a mean subjective score of 83 ± 11 versus 85 ± 12, respectively (mean difference 2, 95% CI 0-5, p = 0.5). CONCLUSIONS Our observations suggest that CAS used for TKA alignment with restoration of a neutral mechanical axis as the goal did not confer any substantial advantage in survivorship, function, or quality of life at 10 years after TKA. Larger studies with longitudinal collection of PROMs for functional assessment and greater numbers to assess survivorship are needed to confirm these findings. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
|
19
|
Siddiqi A, Hardaker WM, Eachempati KK, Sheth NP. Advances in Computer-Aided Technology for Total Knee Arthroplasty. Orthopedics 2017; 40:338-352. [PMID: 28877327 DOI: 10.3928/01477447-20170831-02] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Accepted: 04/17/2017] [Indexed: 02/03/2023]
Abstract
Technology such as computer-assisted navigation systems, robotic-assisted systems, and patient-specific instrumentation has been increasingly explored during the past decade in an effort to optimize component alignment and improve clinical outcomes. Computer-assisted navigation accurately restores mechanical-axis alignment, but clinical outcome data are inconsistent. Computer-assisted navigation gap balancing has shown early promise in establishing mechanical-axis alignment with improved functional outcomes. Robotic-assisted systems more accurately restore component alignment when compared with computer-assisted navigation, but clinical outcomes have yet to be determined. Patient-specific instrumentation does not consistently improve alignment, accuracy, or patient outcomes. Studies demonstrating implant survivorship, cost-efficiency, and improved clinical outcomes and patient satisfaction are needed. [Orthopedics. 2017; 40(6):338-352.].
Collapse
|
20
|
Cip J, Widemschek M, Bach C, Ruckenstuhl P, Benesch T, Studer K, Martin A. Encouraging treatment algorithm for computer-assisted navigated total knee arthroplasty (TKA): A retrospective cohort analysis. J Orthop 2017; 14:377-383. [PMID: 28701852 DOI: 10.1016/j.jor.2017.06.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/07/2017] [Accepted: 06/22/2017] [Indexed: 10/19/2022] Open
Abstract
OBJECTIVE Navigated computer-assisted total knee arthroplasty (TKA) shows inconclusive mid- to long-term outcome results and is limited by increased costs, surgery-time and an additional learning curve. We introduced a treatment algorithm preserving computer-assisted TKA for patients with adipositas-per-magna, posttraumatic leg-deformities, osteosynthetic material in-situ or reduced preoperative X-ray quality. METHODS 237 primary unilateral TKA were allocated based on the treatment concept described above. A retrospective pre- and postoperative radiological analysis was performed. RESULTS 222 TKA (93.7%) were within 3° varus/valgus of mechanical-lower-limb axis (mean absolute deviation: 1.8° ± 1.3°). CONCLUSION This algorithm showed an excellent postoperative implantation-accuracy based on an accurate preoperative surgery-planning.
Collapse
Affiliation(s)
- J Cip
- Department of Orthopedic Surgery, Academic Teaching Hospital Feldkirch, Medical University of Graz, Carinagasse 47, A-6800 Feldkirch, Austria
| | - M Widemschek
- Department of Orthopedic Surgery, Academic Teaching Hospital Feldkirch, Medical University of Graz, Carinagasse 47, A-6800 Feldkirch, Austria
| | - C Bach
- Department of Orthopedic Surgery, Academic Teaching Hospital Feldkirch, Medical University of Graz, Carinagasse 47, A-6800 Feldkirch, Austria
| | - P Ruckenstuhl
- Department of Orthopedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, A-8036 Graz, Austria
| | | | - K Studer
- Department of Pediatric Orthopedic Surgery, Children's Hospital St. Gallen, Claudiusstrasse 6, CH-9006 St. Gallen, Switzerland
| | - A Martin
- Department of Traumatology, Academic Teaching Hospital Bregenz, Carl-Pedenz-Straße 2, A-6900 Bregenz, Austria
| |
Collapse
|
21
|
Niehaus R, Schilter D, Fornaciari P, Weinand C, Boyd M, Ziswiler M, Ehrendorfer S. Experience of total knee arthroplasty using a novel navigation system within the surgical field. Knee 2017; 24:518-524. [PMID: 28117217 DOI: 10.1016/j.knee.2016.10.021] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2016] [Revised: 10/03/2016] [Accepted: 10/31/2016] [Indexed: 02/02/2023]
Abstract
BACKGROUND With the aim of improving component alignment and outcome in total knee arthroplasty (TKA), several computer-assisted devices (CAD) have been developed. METHODS In February 2014, the present unit started to use a new imageless navigation system with accelerometric pods within the surgical field for all primary TKAs; there was no need for optical trackers or cameras. This paper presents the results of the first 72 TKAs using this iAssist system in 71 prospectively collected and retrospectively analyzed patients. It analyzed component positioning in standard and full-length leg x-rays. RESULTS The mean age of the patients was 70years (range 52-88). The center of hip, knee and ankle (mechanical axes) deviated on average 0.5° (standard deviation (SD) of 1.8) valgus from the targeted straight alignment. Three TKAs had >3° deviation (i.e. four degree varus, five degree and seven degree valgus). The frontal tibial tray alignment was an average of 89.9° (range 86.4-100.1°, SD ±2.0) with the target being 90°, and the sagittal slope was as targeted at 85.0° (range 78.4-88.8°, SD ±1.7). CONCLUSIONS This CAD facilitated good mechanical alignment and reproducible accuracy in component positioning. Pods clipped onto cutting jigs within the surgical field provided simple and accurate navigation, with little extra time needed for calibration and no need for optical trackers or pre-operative imaging.
Collapse
Affiliation(s)
- Richard Niehaus
- Department of Orthopaedic Surgery, Kantonsspital Uri (KSU), CH-6460 Altdorf, Switzerland; Balgrist University Hospital, CH 8008 Zurich, Switzerland
| | - David Schilter
- Department of Orthopaedic Surgery, Kantonsspital Uri (KSU), CH-6460 Altdorf, Switzerland
| | - Paolo Fornaciari
- Department of Orthopaedic Surgery, I'HFR Fribourg, Hôpital Cantonal, CH-1700 Fribourg, Switzerland
| | - Christian Weinand
- Department of Plastic and Aesthetic Surgery, Dietrich-Bonhoeffer-Klinikum, Universität Greifswald, 17033 Neubrandenburg, Germany
| | - Marcus Boyd
- Department of Orthopaedic Surgery, Kantonsspital Uri (KSU), CH-6460 Altdorf, Switzerland
| | - Marcel Ziswiler
- Department of Orthopaedic Surgery, Kantonsspital Uri (KSU), CH-6460 Altdorf, Switzerland
| | - Stefan Ehrendorfer
- Department of Orthopaedic Surgery, Kantonsspital Uri (KSU), CH-6460 Altdorf, Switzerland.
| |
Collapse
|
22
|
Ismailidis P, Kuster MS, Jost B, Giesinger K, Behrend H. Clinical outcome of increased flexion gap after total knee arthroplasty. Can controlled gap imbalance improve knee flexion? Knee Surg Sports Traumatol Arthrosc 2017; 25:1705-1711. [PMID: 26846656 DOI: 10.1007/s00167-016-4009-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2015] [Accepted: 01/18/2016] [Indexed: 12/19/2022]
Abstract
PURPOSE Increased range of motion (ROM) while maintaining joint stability is the goal of modern total knee arthroplasty (TKA). A biomechanical study has shown that small increases in flexion gap result in decreased tibiofemoral force beyond 90° flexion. The purpose of this paper was to investigate clinical implications of controlled increased flexion gap. METHODS Four hundred and four TKAs were allocated into one of two groups and analysed retrospectively. In the first group (n = 352), flexion gap exceeded extension gap by 2.5 mm, while in the second group (n = 52) flexion gap was equal to the extension gap. The procedures were performed from 2008 to 2012. The patients were reviewed 12 months postoperatively. Objective clinical results were assessed for ROM, mediolateral and sagittal stability. Patient-reported outcome measures were the WOMAC score and the Forgotten Joint Score (FJS-12). RESULTS After categorizing postoperative flexion into three groups (poor < 90°, satisfactory 91°-119°, good ≥ 120°) significantly more patients in group 1 achieved satisfactory or good ROM (p = 0.006). Group 1 also showed a significantly higher mean FJS-12 (group 1: 73, group 2: 61, p = 0.02). The mean WOMAC score was 11 in the first and 14 in the second group (n.s.). Increase in flexion gap did not influence knee stability. CONCLUSIONS The clinical relevance of this study is that a controlled flexion gap increase of 2.5 mm may have a positive effect on postoperative flexion and patient satisfaction after TKA. Neither knee stability in the coronal and sagittal planes nor complications were influenced by a controlled increase in flexion gap. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- P Ismailidis
- Department of Orthopedic Surgery, University Hospital of Basel, Spitalstrasse 21, 4056, Basel, Switzerland
| | - M S Kuster
- The University of Western Australia, 31 Outram Street, West Perth, WA, 6005, Australia.,Nedlands and PerthOrthopaedic and Sports Medicine Centre, 31 Outram Street, West Perth, WA, 6005, Australia
| | - B Jost
- Department of Orthopaedic Surgery, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland
| | - K Giesinger
- Department of Orthopaedic Surgery, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland
| | - H Behrend
- Department of Orthopaedic Surgery, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland.
| |
Collapse
|
23
|
Kobayashi H, Akamatsu Y, Kumagai K, Kusayama Y, Aratake M, Saito T. Influence of coronal bowing on the lower alignment and the positioning of component in navigation and conventional total knee arthroplasty. Orthop Traumatol Surg Res 2017; 103:251-256. [PMID: 28087396 DOI: 10.1016/j.otsr.2016.11.017] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2016] [Revised: 08/31/2016] [Accepted: 11/04/2016] [Indexed: 02/02/2023]
Abstract
BACKGROUND Coronal alignment is an important factor for the function and longevity of total knee arthroplasty (TKA). Coronal bowing of the lower extremity is common among Asians and it may pose a risk for malalignment of the lower leg and malposition of component. HYPOTHESIS We hypothesized that coronal bowing itself has a risk for malalignment of the lower leg and malposition of femoral/tibial components and that navigation TKA is beneficial for patients with coronal bowing. We investigated the incidence of femoral/tibial bowing in patients treated with TKA and compared the radiographic parameters between the navigation group and the conventional group. Additionally, the influence of coronal bowing on these radiographic parameters was investigated. MATERIALS AND METHODS We enrolled 35 patients with knee osteoarthritis and 70 bilateral simultaneous TKAs. The patients underwent TKA with the use of a computer tomography-free navigation in one knee and conventional TKA in the contralateral knee. Preoperative coronal bowing were measured, and the subjects were divided into 2 subgroups, i.e. the bowing group and the non-bowing group. Lateral bowing was expressed as plus (+) and medial bowing was expressed as minus (-). Various radiographic parameters, including coronal bowing, lower leg alignment, component position, and outliers were compared between the navigation group and the conventional group. RESULTS Femoral bowing varied from -7.4° to 10.9° with an average of 3.0°. Tibial bowing varied from -4.1° to 4.6° with an average of 0.4°. The femoral component was placed more properly in the navigation group. Number of outlier regarding to the coronal femoral component angle to the femoral mechanical axis was 14 cases (37.8%) in the bowing group and 6 cases (18.2%) in the non-bowing group (P=0.04). DISCUSSION In conclusion, coronal femoral bowing has an important effect on femoral bone cut in TKA. The navigated TKA was more consistent than conventional TKA in aiding proper alignments of femoral component. LEVEL OF EVIDENCE Level II, comparative prospective study.
Collapse
Affiliation(s)
- H Kobayashi
- Department of orthopaedic surgery, Yokohama city university, school of medicine, 3-9, Fukuura, Kanazawa, Yokohama, Kanagawa 236-0004, Japan.
| | - Y Akamatsu
- Department of orthopaedic surgery, Yokohama city university, school of medicine, 3-9, Fukuura, Kanazawa, Yokohama, Kanagawa 236-0004, Japan
| | - K Kumagai
- Department of orthopaedic surgery, Yokohama city university, school of medicine, 3-9, Fukuura, Kanazawa, Yokohama, Kanagawa 236-0004, Japan
| | - Y Kusayama
- Department of orthopaedic surgery, Yokohama city university, school of medicine, 3-9, Fukuura, Kanazawa, Yokohama, Kanagawa 236-0004, Japan
| | - M Aratake
- Department of orthopaedic surgery, Yokohama city university, school of medicine, 3-9, Fukuura, Kanazawa, Yokohama, Kanagawa 236-0004, Japan
| | - T Saito
- Department of orthopaedic surgery, Yokohama city university, school of medicine, 3-9, Fukuura, Kanazawa, Yokohama, Kanagawa 236-0004, Japan
| |
Collapse
|
24
|
Petursson G, Fenstad AM, Gøthesen Ø, Haugan K, Dyrhovden GS, Hallan G, Röhrl SM, Aamodt A, Nilsson KG, Furnes O. Similar migration in computer-assisted and conventional total knee arthroplasty. Acta Orthop 2017; 88:166-172. [PMID: 27996349 PMCID: PMC5385111 DOI: 10.1080/17453674.2016.1267835] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Accepted: 09/19/2016] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Computer-assisted surgery (CAS) in total knee arthroplasty (TKA) has been used in recent years in the hope of improving the alignment and positioning of the implant, thereby achieving a better functional outcome and durability. However, the role of computer navigation in TKA is still under debate. We used radiostereometric analysis (RSA) in a randomized controlled trial (RCT) to determine whether there are any differences in migration of the tibial component between CAS- and conventionally (CONV-) operated TKA. Patients and methods - 54 patients (CAS, n = 26; CONV, n = 28) with a mean age of 67 (56-78) years and with osteoarthritis or arthritic disease of the knee were recruited from 4 hospitals during the period 2009-2011. To estimate the mechanical stability of the tibial component, the patients were examined with RSA up to 24 months after operation. The following parameters representing tibial component micromotion were measured: 3-D vector of the prosthetic marker that moved the most, representing the magnitude of migration (maximum total point motion, MTPM); the largest negative value for y-translation (subsidence); the largest positive y-translation (lift-off); and prosthetic rotations. The precision of the RSA measurements was evaluated and migration in the 2 groups was compared. Results - Both groups had most migration within the first 3 months, but there was no statistically significant difference in the magnitude of the migration between the CAS group and the CONV group. From 3 to 24 months, the MTPM (in mm) was 0.058 and 0.103 (p = 0.1) for the CAS and CON groups, respectively, and the subsidence (in mm) was 0.005 and 0.011 (p = 0.3). Interpretation - Mean MTPM, subsidence, lift-off, and rotational movement of tibial trays were similar in CAS- and CONV-operated knees.
Collapse
Affiliation(s)
- Gunnar Petursson
- Lovisenberg Diakonale Hospital, Oslo
- The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen
| | - Anne Marie Fenstad
- The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen
| | - Øystein Gøthesen
- The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen
- Department of Clinical Medicine, Institute of Medicine and Dentistry, University of Bergen, Bergen
- Haugesund Hospital, Haugesund
| | - Kristin Haugan
- Orthopaedic Research Center, Trondheim University Hospital, Trondheim
| | - Gro Sævik Dyrhovden
- The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen
- Department of Clinical Medicine, Institute of Medicine and Dentistry, University of Bergen, Bergen
| | - Geir Hallan
- Department of Clinical Medicine, Institute of Medicine and Dentistry, University of Bergen, Bergen
| | - Stephan M Röhrl
- Department of Orthopaedics, Oslo University Hospital, Ullevål, Oslo, Norway
| | | | - Kjell G Nilsson
- Department of Surgical and Perioperative Sciences, Orthopaedics, Umeå University, Umeå, Sweden
| | - Ove Furnes
- The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen
- Department of Clinical Medicine, Institute of Medicine and Dentistry, University of Bergen, Bergen
| |
Collapse
|
25
|
Abstract
Recent studies have challenged the long-held notion that neutral mechanical alignment after total knee arthroplasty leads to optimal function and survivorship. The ideal alignment for function and survivorship may actually be different. Kinematic alignment, where components are implanted to re-create the natural flexion/extension axis of the knee, may lead to improved functional results. Residual varus alignment may not adversely impact survivorship provided the tibial component is implanted in neutral alignment.
Cite this article: Lording T, Lustig S, Neyret P. Coronal alignment after total knee arthroplasty. EFORT Open Rev 2016;1:12-17. doi: 10.1302/2058-5241.1.000002.
Collapse
Affiliation(s)
- Timothy Lording
- Melbourne Orthopaedic Group and The Alfred Hospital, Australia
| | - Sébastien Lustig
- Albert Trillat Center, Groupement Hospitalier Nord, Université Lyon 1, France
| | - Philippe Neyret
- Albert Trillat Center, Groupement Hospitalier Nord, Université Lyon 1, France
| |
Collapse
|
26
|
Hasegawa M, Miyazaki S, Yamaguchi T, Wakabayashi H, Sudo A. Comparison of Midterm Outcomes of Minimally Invasive Computer-Assisted vs Minimally Invasive Jig-Based Total Knee Arthroplasty. J Arthroplasty 2017; 32:43-46. [PMID: 27503697 DOI: 10.1016/j.arth.2016.07.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Revised: 07/01/2016] [Accepted: 07/01/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Minimally invasive surgery (MIS) has perceived advantages in the early postoperative stage for total knee arthroplasty (TKA). It is not clear whether the improved radiographic alignment achieved by computer-assisted navigation surgery (CAS) improves midterm clinical outcomes. The aim of this study was to compare patient outcomes of MIS TKA performed with and without CAS after a minimum follow-up of 7 years. METHODS Between 2007 and 2009, 50 patients underwent CAS and MIS TKA, and 50 patients underwent jig-based MIS TKA in this prospective study. Ninety-six patients were evaluated after a mean follow-up of 7.7 years, and clinical and radiological evaluations were performed. RESULTS Midterm results demonstrated that the Knee Society knee score, function score, and range of motion were comparable in the 2 groups. The percentage of patients with the mechanical axis within ±3° of neutral was significantly higher in the CAS group than in the jig-based group (94% vs 79%, respectively; P = .038). No knees had loosening after TKA. However, 1 patient in the CAS group demonstrated late infection 4 years postoperatively. CONCLUSION CAS did not improve midterm outcomes after MIS TKA compared with jig-based surgery, although CAS reduced outliers in coronal alignment.
Collapse
Affiliation(s)
- Masahiro Hasegawa
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Shinichi Miyazaki
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Toshio Yamaguchi
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Hiroki Wakabayashi
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Akihiro Sudo
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| |
Collapse
|
27
|
Song EK, Agrawal PR, Kim SK, Seo HY, Seon JK. A randomized controlled clinical and radiological trial about outcomes of navigation-assisted TKA compared to conventional TKA: long-term follow-up. Knee Surg Sports Traumatol Arthrosc 2016; 24:3381-3386. [PMID: 26831857 DOI: 10.1007/s00167-016-3996-2] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2015] [Accepted: 01/13/2016] [Indexed: 11/24/2022]
Abstract
PURPOSE Well balanced knees with good alignment are essential for a well-functioning TKA with long survival of its implants. This prospective randomized study comparing navigation-assisted TKA and conventional TKA reported the clinical and radiological outcomes at a follow-up of 9 years. The purpose of this study was to compare the clinical and radiological outcomes for patients who underwent navigation-assisted TKA or conventional TKA after long-term follow-up. METHODS A total of 80 patients (88 knees) were available for physical and radiological examination 9 years after TKA. Clinical outcomes were evaluated using HSS, WOMAC, and KS function and pain scores. And radiological outcomes of the component loosening and its survivorship during 9-year follow-up were also evaluated. RESULTS There were no significant differences in the field of clinical outcomes between the two groups. In terms of radiological outcomes, the navigation group had fewer alignment outliers (7.3 vs 20 %, p = 0.006). Although the clinical outcomes showed no differences between the two groups, the survival rate was slightly better in the navigation group than in the conventional group without statistical significance (best-case scenario 100 vs 95.3 %, n.s., worst-case scenario 95.6 vs 88.4 %, n.s.). CONCLUSION Navigation-assisted TKA produced better alignment outcomes and better survival rates than conventional instruments although some of the differences were not statistically significant. LEVEL OF EVIDENCE I.
Collapse
Affiliation(s)
- E K Song
- Department of Orthopedic Surgery, Center for Joint Disease, Chonnam National University Hwasun Hospital, 160Ilsimri, Hwasun-eup, Hwasun-gun, Jeollanamdo, 519-809, South Korea
| | - Pranav R Agrawal
- Department of Orthopedic Surgery, Center for Joint Disease, Chonnam National University Hwasun Hospital, 160Ilsimri, Hwasun-eup, Hwasun-gun, Jeollanamdo, 519-809, South Korea
| | - S K Kim
- Department of Orthopedic Surgery, Chonnam National University Hospital, Gwangju, South Korea
| | - H Y Seo
- Department of Orthopedic Surgery, Chonnam National University Hospital, Gwangju, South Korea
| | - J K Seon
- Department of Orthopedic Surgery, Center for Joint Disease, Chonnam National University Hwasun Hospital, 160Ilsimri, Hwasun-eup, Hwasun-gun, Jeollanamdo, 519-809, South Korea.
| |
Collapse
|
28
|
van der List JP, Chawla H, Joskowicz L, Pearle AD. Current state of computer navigation and robotics in unicompartmental and total knee arthroplasty: a systematic review with meta-analysis. Knee Surg Sports Traumatol Arthrosc 2016; 24:3482-3495. [PMID: 27600634 DOI: 10.1007/s00167-016-4305-9] [Citation(s) in RCA: 114] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/13/2016] [Accepted: 08/30/2016] [Indexed: 12/11/2022]
Abstract
Recently, there is a growing interest in surgical variables that are intraoperatively controlled by orthopaedic surgeons, including lower leg alignment, component positioning and soft tissues balancing. Since more tight control over these factors is associated with improved outcomes of unicompartmental knee arthroplasty and total knee arthroplasty (TKA), several computer navigation and robotic-assisted systems have been developed. Although mechanical axis accuracy and component positioning have been shown to improve with computer navigation, no superiority in functional outcomes has yet been shown. This could be explained by the fact that many differences exist between the number and type of surgical variables these systems control. Most systems control lower leg alignment and component positioning, while some in addition control soft tissue balancing. Finally, robotic-assisted systems have the additional advantage of improving surgical precision. A systematic search in PubMed, Embase and Cochrane Library resulted in 40 comparative studies and three registries on computer navigation reporting outcomes of 474,197 patients, and 21 basic science and clinical studies on robotic-assisted knee arthroplasty. Twenty-eight of these comparative computer navigation studies reported Knee Society Total scores in 3504 patients. Stratifying by type of surgical variables, no significant differences were noted in outcomes between surgery with computer-navigated TKA controlling for alignment and component positioning versus conventional TKA (p = 0.63). However, significantly better outcomes were noted following computer-navigated TKA that also controlled for soft tissue balancing versus conventional TKA (mean difference 4.84, 95 % Confidence Interval 1.61, 8.07, p = 0.003). A literature review of robotic systems showed that these systems can, similarly to computer navigation, reliably improve lower leg alignment, component positioning and soft tissues balancing. Furthermore, two studies comparing robotic-assisted with computer-navigated surgery reported superiority of robotic-assisted surgery in controlling these factors. Manually controlling all these surgical variables can be difficult for the orthopaedic surgeon. Findings in this study suggest that computer navigation or robotic assistance may help managing these multiple variables and could improve outcomes. Future studies assessing the role of soft tissue balancing in knee arthroplasty and long-term follow-up studies assessing the role of computer-navigated and robotic-assisted knee arthroplasty are needed.
Collapse
Affiliation(s)
- Jelle P van der List
- Department of Orthopaedic Surgery, Computer Assisted Surgery Center, Hospital for Special Surgery, Weill Medical College of Cornell University, 535 E. 70th Street, New York, NY, 10021, USA.
| | - Harshvardhan Chawla
- Department of Orthopaedic Surgery, Computer Assisted Surgery Center, Hospital for Special Surgery, Weill Medical College of Cornell University, 535 E. 70th Street, New York, NY, 10021, USA
| | - Leo Joskowicz
- Computer Assisted Surgery and Medical Image Processing Laboratory, School of Engineering and Computer Science, Hebrew University, Jerusalem, Israel
| | - Andrew D Pearle
- Department of Orthopaedic Surgery, Computer Assisted Surgery Center, Hospital for Special Surgery, Weill Medical College of Cornell University, 535 E. 70th Street, New York, NY, 10021, USA
| |
Collapse
|
29
|
Hinarejos P, Puig-Verdie L, Leal J, Pelfort X, Torres-Claramunt R, Sánchez-Soler J, Monllau JC. No differences in functional results and quality of life after single-radius or multiradius TKA. Knee Surg Sports Traumatol Arthrosc 2016; 24:2634-40. [PMID: 26658566 DOI: 10.1007/s00167-015-3894-z] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2015] [Accepted: 11/23/2015] [Indexed: 10/22/2022]
Abstract
PURPOSE The main objective of this study was to compare the functional results and the impact on quality of life after a single-radius or a multiradius TKA implantation. The secondary objectives were to compare range of motion, satisfaction and the ability to perform daily life activities with both types of implant. It was hypothesized that the single-radius TKA would lead to better functional results and better quality of life than the multiradius TKA. METHODS This is a prospective non-randomized study that included 250 cases of a single-radius TKA and 224 of a multiradius posterior-stabilized TKA implanted with the same surgical and rehabilitation protocol. RESULTS In the 1- and 5-year follow-up, we found similar knee KSS scores (89.7 ± 12.1 in the multiradius group and 90.3 ± 11.7 in the single-radius group) and functional KSS scores (78.6 ± 21.4 in the multiradius group and 75.8 ± 20.9 in the single-radius group). The pain and the Physical SF-36 scores were also similar. Range of motion (112° ± 12° in the multiradius group and 112 ± 12° in the single-radius group), patients' satisfaction and the ability to perform daily life activities were also similar in both groups. CONCLUSION The use of a single-radius or a multiradius posterior-stabilized knee prosthesis can improve the function of the knee and the patients' quality of life in a similar way at the short-term and midterm follow-up. Moreover, range of motion, patient satisfaction and the ability to perform daily life activities are similar with both types of prosthesis. As both types of prosthesis can improve the function and quality of life of the patients in a similar way, the sagittal radius of the femoral component should not be considered the main factor when choosing the model of TKA. LEVEL OF EVIDENCE Therapeutic study: Prospective comparative study, Level II.
Collapse
Affiliation(s)
- Pedro Hinarejos
- Department of Orthopaedic Surgery, Parc de Salut Mar. (Spain), Universitat Autònoma de Barcelona, Sant Josep de la Muntanya, 12, 08024, Barcelona, Spain.
| | - Lluis Puig-Verdie
- Department of Orthopaedic Surgery, Parc de Salut Mar. (Spain), Universitat Autònoma de Barcelona, Sant Josep de la Muntanya, 12, 08024, Barcelona, Spain
| | - Joan Leal
- Department of Orthopaedic Surgery, Parc de Salut Mar. (Spain), Universitat Autònoma de Barcelona, Sant Josep de la Muntanya, 12, 08024, Barcelona, Spain
| | - Xavier Pelfort
- Department of Orthopaedic Surgery, Parc de Salut Mar. (Spain), Universitat Autònoma de Barcelona, Sant Josep de la Muntanya, 12, 08024, Barcelona, Spain
| | - Raul Torres-Claramunt
- Department of Orthopaedic Surgery, Parc de Salut Mar. (Spain), Universitat Autònoma de Barcelona, Sant Josep de la Muntanya, 12, 08024, Barcelona, Spain
| | - Juan Sánchez-Soler
- Department of Orthopaedic Surgery, Parc de Salut Mar. (Spain), Universitat Autònoma de Barcelona, Sant Josep de la Muntanya, 12, 08024, Barcelona, Spain
| | - Joan C Monllau
- Department of Orthopaedic Surgery, Parc de Salut Mar. (Spain), Universitat Autònoma de Barcelona, Sant Josep de la Muntanya, 12, 08024, Barcelona, Spain
| |
Collapse
|
30
|
Liow MHL, Goh GSH, Pang HN, Tay DKJ, Lo NN, Yeo SJ. Computer-assisted stereotaxic navigation improves the accuracy of mechanical alignment and component positioning in total knee arthroplasty. Arch Orthop Trauma Surg 2016; 136:1173-80. [PMID: 27349233 DOI: 10.1007/s00402-016-2483-z] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2016] [Indexed: 12/14/2022]
Abstract
INTRODUCTION This study reports on a novel computer-assisted stereotaxic navigation (CASN) system that attempts to combine the accuracy of computer navigation with familiarity of conventional methods. We hypothesize that CASN would improve mechanical alignment and component positioning when compared to conventional instrumentation. MATERIALS AND METHODS 145 patients (192 knees) retrospectively matched for age, BMI, gender and pre-operative scores, underwent total knee arthroplasty (TKA) using CASN (n = 92) or conventional instrumentation (n = 100). Pre- and post-operative radiological alignment [Acceptable ranges: mechanical axis (MA) 0° ± 3°, coronal femoral-component angle (CFA) and coronal tibia-component angle (CTA) 90° ± 3°] and clinical outcomes (Knee Society Scores, Oxford Knee Score and Short Form-36) at 6 months were examined. RESULTS The CASN group had significantly improved mean MA (1.9° ± 1.4°, versus 2.8° ± 2.0° in the conventional group, p = 0.001), CFA (1.6° ± 1.3°, versus 2.1° ± 1.5° in the conventional group, p = 0.035) and CTA (1.6° ± 1.2°, versus 2.1° ± 1.5° in the conventional group, p = 0.024). 91.3 % of knees in the CASN group were within 3° of a neutral mechanical axis, versus 74 % in the conventional group (p < 0.001). The duration of surgery was significantly longer in the CASN group (84 ± 22 vs 73 ± 15 min, p = 0.001) and cost an additional USD 850 per operation. There were no significant differences in clinical outcomes or satisfaction rates at 6 months post-operatively (p > 0.05). CONCLUSIONS CASN improved TKA mechanical alignment and component positioning, however, resulted in longer and costlier surgery with no benefits in short-term functional outcomes, despite providing familiarity to surgeons accustomed to conventional instrumentation. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Ming Han Lincoln Liow
- Department of Orthopaedic Surgery, Singapore General Hospital, 20 College Road, Academia, Level 4, Singapore, 169865, Singapore. .,Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Boston, 02114, Massachusetts, USA.
| | - Graham Seow-Hng Goh
- Department of Orthopaedic Surgery, Singapore General Hospital, 20 College Road, Academia, Level 4, Singapore, 169865, Singapore
| | - Hee-Nee Pang
- Department of Orthopaedic Surgery, Singapore General Hospital, 20 College Road, Academia, Level 4, Singapore, 169865, Singapore
| | - Darren Keng Jin Tay
- Department of Orthopaedic Surgery, Singapore General Hospital, 20 College Road, Academia, Level 4, Singapore, 169865, Singapore
| | - Ngai Nung Lo
- Department of Orthopaedic Surgery, Singapore General Hospital, 20 College Road, Academia, Level 4, Singapore, 169865, Singapore
| | - Seng Jin Yeo
- Department of Orthopaedic Surgery, Singapore General Hospital, 20 College Road, Academia, Level 4, Singapore, 169865, Singapore
| |
Collapse
|
31
|
Reliable Alignment in Total Knee Arthroplasty by the Use of an iPod-Based Navigation System. Adv Orthop 2016; 2016:2606453. [PMID: 27313898 PMCID: PMC4904084 DOI: 10.1155/2016/2606453] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2016] [Revised: 05/09/2016] [Accepted: 05/10/2016] [Indexed: 11/17/2022] Open
Abstract
Axial alignment is one of the main objectives in total knee arthroplasty (TKA). Computer-assisted surgery (CAS) is more accurate regarding limb alignment reconstruction compared to the conventional technique. The aim of this study was to analyse the precision of the innovative navigation system DASH® by Brainlab and to evaluate the reliability of intraoperatively acquired data. A retrospective analysis of 40 patients was performed, who underwent CAS TKA using the iPod-based navigation system DASH. Pre- and postoperative axial alignment were measured on standardized radiographs by two independent observers. These data were compared with the navigation data. Furthermore, interobserver reliability was measured. The duration of surgery was monitored. The mean difference between the preoperative mechanical axis by X-ray and the first intraoperatively measured limb axis by the navigation system was 2.4°. The postoperative X-rays showed a mean difference of 1.3° compared to the final navigation measurement. According to radiographic measurements, 88% of arthroplasties had a postoperative limb axis within ±3°. The mean additional time needed for navigation was 5 minutes. We could prove very good precision for the DASH system, which is comparable to established navigation devices with only negligible expenditure of time compared to conventional TKA.
Collapse
|
32
|
D'Costa E, Sivakumar B, Tsung J. Optimal Number of Fixation Pins for Dedicated Mini Jig Cutting Guides During Navigated Total Knee Arthroplasty. J INVEST SURG 2016; 29:323-327. [PMID: 27010612 DOI: 10.3109/08941939.2015.1128996] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE The optimal number of fixation pins for minimally invasive cutting guides in computer-navigated arthroplasty has not been determined. The authors hypothesized that more fixation pins will lead to greater mechanical stability and more accurate resections. MATERIALS AND METHOD 12 bovine knee joints were divided into three groups with differing numbers of fixation pins. The ASM [Stryker] knee navigation system was utilized to perform resections, and accuracy of alignment and posterior slope was measured. Comparison was performed between the groups to calculate average differences between predicted and actual resection with differing number of pins. RESULTS The difference between actual and predicted values showed a trend toward diminishing with a greater number of fixation pins. The mean difference in coronal alignment of predicted versus actual resection was 0.75° for two fixation pins, 0.5° for three pins and 1° for four fixation pins. Similarly, the difference between posterior slope was 2.75°, 2°, and 1°, respectively. CONCLUSION This study reveals a trend toward greater accuracy of resections with more fixation pins. Further investigation may be beneficial.
Collapse
Affiliation(s)
- Elliott D'Costa
- a Department of Orthopaedic Surgery , The Tweed Hospital , Tweed Heads , Australia
| | | | - Jason Tsung
- b Tweed Heads Hospital , Tweed Heads , NSW , 2485
| |
Collapse
|
33
|
Ochs BG, Schreiner AJ, de Zwart PM, Stöckle U, Gonser CE. Computer-assisted navigation is beneficial both in primary and revision surgery with modular rotating-hinge knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2016; 24:64-73. [PMID: 25239506 DOI: 10.1007/s00167-014-3316-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2013] [Accepted: 09/09/2014] [Indexed: 11/30/2022]
Abstract
PURPOSE The objective of the present study was to explore the effect of navigation on the reconstruction of the mechanical leg axis, implant positioning and the restoration of the joint line in hinged knee arthroplasty in vivo. We present the first 1- to 3-year clinical and radiological results following computer-navigated implantation of the EnduRo modular rotating-hinge knee arthroplasty system (Aesculap AG, Tuttlingen, Germany) as a primary or revision implant. METHODS Thirty-one patients were analysed retrospectively. Indication was revision surgery in 18 patients and complex primary surgery in 13. The clinical and radiological results of 31 patients with a minimum follow-up of 12 months (mean 22.2 ± 6.2 months) were recorded. Age at follow-up was 55.2 ± 9.9 years. RESULTS The absolute varus-valgus deviation from the neutral mechanical leg axis was determined at 5.1° ± 5.1° preoperatively and 2.1° ± 1.4° postoperatively. No intraoperative complications or problems with the navigation system were observed. At latest follow-up, no component loosening was detected. Based on the Knee Society Score, a knee score of 64.9 ± 17.7 points and a function score of 67.2 ± 27.3 points were achieved. CONCLUSIONS Encouraging short-term clinical and radiological results with the computer-navigated implantation of the modular rotating-hinge EnduRo knee arthroplasty system were found in both primary and revision surgery. The navigation facilitated the reconstruction of the leg axis, implant positioning and the restoration of the joint line. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Björn G Ochs
- BG Trauma Centre, Eberhard Karls University of Tübingen, Schnarrenbergstraße 95, 72076, Tübingen, Germany
| | - Anna J Schreiner
- BG Trauma Centre, Eberhard Karls University of Tübingen, Schnarrenbergstraße 95, 72076, Tübingen, Germany
| | - Peter M de Zwart
- BG Trauma Centre, Eberhard Karls University of Tübingen, Schnarrenbergstraße 95, 72076, Tübingen, Germany
| | - Ulrich Stöckle
- BG Trauma Centre, Eberhard Karls University of Tübingen, Schnarrenbergstraße 95, 72076, Tübingen, Germany
| | - Christoph Emanuel Gonser
- BG Trauma Centre, Eberhard Karls University of Tübingen, Schnarrenbergstraße 95, 72076, Tübingen, Germany.
| |
Collapse
|
34
|
A Systematic Literature Review of Three Modalities in Technologically Assisted TKA. Adv Orthop 2015; 2015:719091. [PMID: 26664755 PMCID: PMC4667026 DOI: 10.1155/2015/719091] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2015] [Revised: 10/09/2015] [Accepted: 10/12/2015] [Indexed: 01/13/2023] Open
Abstract
In effort to reduce the revision burden of total knee arthroplasty (TKA), industry emphasis has focused on replacing manual techniques—which are subject to variability—with technological implements. Unfortunately, technological innovation often continues before adequate time for critical evaluation has passed. Therefore, the purpose of this descriptive literature review was to collect a large sample of international data and report on the clinical and economic efficacy of three major types of technologically assisted TKA: navigation, patient-specific instrumentation, and sensorized trials.
Collapse
|
35
|
Radiological and Functional Outcomes in Computer Assisted Total Knee Arthroplasty Between Consultants and Trainees - A Prospective Randomized Controlled Trial. J Arthroplasty 2015; 30:1344-7. [PMID: 25820119 DOI: 10.1016/j.arth.2015.03.007] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/26/2014] [Revised: 03/03/2015] [Accepted: 03/07/2015] [Indexed: 02/01/2023] Open
Abstract
Computer Aided Surgery has consistently shown superior alignment of components when compared to non-navigated jig based techniques. The aim of this study is to assess the mid-term clinical outcome of TKA performed by a consultant orthopedic surgeon, compared to trainee surgeons. Ninety-two patients were matched and randomly allocated to have CAS surgery performed by either a consultant or trainee and followed up prospectively for 5-years. Knee society scores, mechanical axis, tourniquet time and blood loss data were collected. Our study demonstrated that trainees were able to achieve equal coronal alignment (P=0.15), blood loss (P=0.45) and functional scores (P=0.15). The Consultant group had a significantly (P<0.001) shorter tourniquet time. We confirm that CAS can assist less experienced surgeons to reliably achieve good mid-term outcomes in TKA.
Collapse
|
36
|
Carli A, Aoude A, Reuven A, Matache B, Antoniou J, Zukor DJ. Inconsistencies between navigation data and radiographs in total knee arthroplasty are system-dependent and affect coronal alignment. Can J Surg 2015; 57:305-13. [PMID: 25265103 DOI: 10.1503/cjs.031313] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND Few studies have compared the effect of different computer navigation systems on postoperative alignment in patients who have had total knee arthroplasty (TKA). We examined 2 computed tomography (CT)-free computer navigation systems by comparing the accuracy of intraoperative measurements to postoperative alignment. METHODS Patients underwent unilateral TKA performed by a single surgeon using 1 of 2 CT-free navigation systems. We compared final intraoperative tibial and femoral coronal angles and mechanical axis with the same angles measured on standing postoperative radiographs. RESULTS Groups of 31 and 50 patients underwent TKA with the 2 systems, respectively. We noted a significant difference in the coronal tibial implant angle (1.29º ± 1.35º) and in the mechanical axis (1.59º ± 2.36º) for one navigation system (both p < 0.001), while only the coronal tibial implant angle showed a significant difference (1.17º ± 1.65º, p < 0.001) for the second system. The number of radiographic outliers also significantly differed. A significantly higher proportion (32%; p < 0.01) of patients in the second cohort exhibited unacceptable malalignment compared with the first cohort (24%). CONCLUSION Navigation systems for TKA continue to increase in sophistication and popularity. Owing to the significant difference in the proportion of alignment outliers in the 2 navigation systems tested in this study, orthopedic surgeons should not consider all TKA navigation systems equivalent. Additional investigations are needed to compare the accuracy of a variety of CT-free and CT-based navigation systems and to confirm our finding that accuracy is system-dependent.
Collapse
Affiliation(s)
- Alberto Carli
- The Division of Orthopaedic Surgery, McGill University, Montréal, Que
| | - Ahmed Aoude
- The Division of Orthopaedic Surgery, McGill University, Montréal, Que
| | - Avishai Reuven
- The Division of Orthopaedic Surgery, Lady Davis Institute for Medical Research-Jewish General Hospital, McGill University, Montréal, Que
| | - Bogdan Matache
- The Division of Orthopaedic Surgery, McGill University, Montréal, Que
| | - John Antoniou
- The Division of Orthopaedic Surgery, Lady Davis Institute for Medical Research-Jewish General Hospital, McGill University, Montréal, Que
| | - David J Zukor
- The Division of Orthopaedic Surgery, Lady Davis Institute for Medical Research-Jewish General Hospital, McGill University, Montréal, Que
| |
Collapse
|
37
|
Asada S, Mori S, Matsushita T, Nakagawa K, Tsukamoto I, Akagi M. Comparison of MRI- and CT-based patient-specific guides for total knee arthroplasty. Knee 2014; 21:1238-43. [PMID: 25199712 DOI: 10.1016/j.knee.2014.08.015] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2013] [Revised: 08/04/2014] [Accepted: 08/13/2014] [Indexed: 02/02/2023]
Abstract
BACKGROUND The patient-specific guide for total knee arthroplasty (TKA) is created from the data provided by magnetic resonance imaging (MRI) or computed tomography (CT) scans. It remains unknown which imaging technology is suitable for the patient-specific guide. The purpose of this study was to compare the accuracy of implant positioning and operative times between the two types of patient-specific guides for TKA. METHODS Forty arthritic knees were divided into two treatment groups using MRI-based (PS-MRI group) or CT-based (PS-CT group) patient-specific guides in this prospective, comparative study. The guide in the PS-MRI group had a cutting slot, whereas that in the PS-CT group only had a pin locator. The operative times were compared between the two groups. The angular error and number of outliers (deviations >3°) of the implant position using pre- and postoperative CT were investigated in both groups. RESULTS The mean operative time was significantly shorter in the PS-MRI group (109.2 ± 16.5 min) than in the PS-CT group (129.5 ± 19.4 min) (p<0.001). There were no significant differences in the accuracy of the implant position regarding the coronal, sagittal, and axial planes between the groups (p>0.05). CONCLUSIONS To reduce the operative time, guides with additional functions, such as cutting and positioning, should be used. Both CT- and MRI-based-guides would result in the same accuracy in three planes but high inaccuracy in the sagittal plane. The use of patient-specific guide based on MRI might not be cost-effective. LEVEL OF EVIDENCE level 2.
Collapse
Affiliation(s)
- Shigeki Asada
- Department of Orthopaedic Surgery, Kinki University Faculty of Medicine, Japan.
| | - Shigeshi Mori
- Department of Orthopaedic Surgery, Kinki University Faculty of Medicine, Japan
| | - Tetsunao Matsushita
- Department of Orthopaedic Surgery, Kinki University Faculty of Medicine, Japan
| | - Koichi Nakagawa
- Department of Orthopaedic Surgery, Kinki University Faculty of Medicine, Japan
| | - Ichiroh Tsukamoto
- Department of Orthopaedic Surgery, Kinki University Faculty of Medicine, Japan
| | - Masao Akagi
- Department of Orthopaedic Surgery, Kinki University Faculty of Medicine, Japan
| |
Collapse
|
38
|
Huang TW, Peng KT, Huang KC, Lee MS, Hsu RWW. Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2014; 22:2954-61. [PMID: 25331655 DOI: 10.1007/s00167-014-3331-8] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2013] [Accepted: 09/15/2014] [Indexed: 11/29/2022]
Abstract
PURPOSE Marked coronal femoral bowing may bear a risk for mal-alignment of femoral component and reconstructed mechanical axis (MA) by using conventional instrumentations. The aim of this study was to investigate the usefulness of computer-assisted surgery-total knee arthroplasty (CAS-TKA) under this circumstance. METHODS We retrospectively analyzed patients with osteoarthritic knee and marked coronal femoral bowing who underwent TKA at our institution. The CAS-TKA and the conventional techniques were compared by radiographic parameters in coronal and sagittal planes, and rotational alignment of femoral component was assessed by computed tomography (CT) scans. The Hospital for Special Surgery (HSS) and International Knee Society (IKS) scores were obtained for all patients preoperatively and at the last follow-up. RESULTS A total of 65 knees were enrolled in this study. Twenty-eight TKAs implanted using a CT-free navigation system, and the remaining 37 TKAs implanted using the conventional technique. CAS-TKAs were more consistent than conventional TKAs in aiding proper postoperative MA and ideal alignments of femoral component in the coronal and sagittal planes. However, CAS-TKA group was not obtained at significantly higher rates of femoral component in axial plane. At a mean follow-up of 43 months, there was no significant difference in HSS and IKS scores between the groups. CONCLUSIONS Although CAS-TKA did not have superior functional outcomes in the short-term follow-up, proper coronal and sagittal alignment of femoral component and postoperative MA were obtained in patients with marked coronal femoral bowing. The long-term follow-up will be needed to clarify the eventual benefits. LEVEL OF EVIDENCE Retrospective comparative study, Level III.
Collapse
Affiliation(s)
- Tsan-Wen Huang
- Division of Joint Reconstruction, Department of Orthopaedic Surgery, Chang Gung Memorial Hospital, Chiayi, No. 6, West Section, Chia-Pu Road, Putz, 613, Chia-Yi, Taiwan
| | | | | | | | | |
Collapse
|
39
|
Conventional versus computer-assisted technique for total knee arthroplasty: a minimum of 5-year follow-up of 200 patients in a prospective randomized comparative trial. J Arthroplasty 2014; 29:1795-802. [PMID: 24906519 DOI: 10.1016/j.arth.2014.04.037] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2013] [Revised: 04/21/2014] [Accepted: 04/28/2014] [Indexed: 02/01/2023] Open
Abstract
In the literature, studies of computer-assisted total knee arthroplasty (TKA) after mid-term period are not conclusive and long-term data are rare. In a prospective, randomized, comparative study 100 conventional TKAs (group REG) were compared with 100 computer-assisted TKAs (group NAV). Minimum follow-up was 5years. No difference in implant failure was found with 1.1% in group NAV versus 4.6% in group REG (P=0.368). Group NAV showed a significantly less mean deviation of mechanical limb axis (P=0.015), more TKAs (90% versus 81% in group REG) were within 3° varus/valgus and a higher tibial slope and lateral distal femoral angle (LDFA) accuracy was found (P≤0.034). Clinical investigational parameters showed no differences (P≥0.058). Insall and HSS score total were also higher in group NAV (P≤0.016).
Collapse
|
40
|
Conteduca F, Iorio R, Mazza D, Ferretti A. Patient-specific instruments in total knee arthroplasty. INTERNATIONAL ORTHOPAEDICS 2014; 38:259-65. [PMID: 24390008 DOI: 10.1007/s00264-013-2230-9] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2013] [Accepted: 11/25/2013] [Indexed: 12/29/2022]
Abstract
PURPOSE In recent years, patient-specific instruments (PSI) has been introduced with the aim of reducing the overall costs of the implants, minimising the size and number of instruments required, and also reducing surgery time. The purpose of this study was to perform a review of the current literature, as well as to report about our personal experience, to assess reliability of patient specific instrument system in total knee arthroplasty (TKA). METHODS A literature review was conducted of PSI system reviewing articles related to coronal alignment, clinical knee and function scores, cost, patient satisfaction and complications. RESULTS Studies have reported incidences of coronal alignment ≥3° from neutral in TKAs performed with patient-specific cutting guides ranging from 6% to 31%. CONCLUSIONS PSI seem not to be able to result in the same degree of accuracy as the CAS system, while comparing well with standard manual technique with respect to component positioning and overall lower axis, in particular in the sagittal plane. In cases in which custom-made cutting jigs were used, we recommend performing an accurate control of the alignment before and after any cuts and in any further step of the procedure, in order to avoid possible outliers.
Collapse
Affiliation(s)
- Fabio Conteduca
- Orthopaedic Unit and "Kirk Kilgour" Sports Injury Centre, S. Andrea Hospital, University of Rome "Sapienza", Via Grottarossa 1035, Rome, Italy
| | | | | | | |
Collapse
|
41
|
Thienpont E, Bellemans J, Victor J, Becker R. Alignment in total knee arthroplasty, still more questions than answers…. Knee Surg Sports Traumatol Arthrosc 2013; 21:2191-3. [PMID: 23979517 DOI: 10.1007/s00167-013-2622-9] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Affiliation(s)
- Emmanuel Thienpont
- Department of Orthopedics and Traumatology, University hospital Saint Luc - UCL, Av Hippocrate 10, 1200, Brussels, Belgium,
| | | | | | | |
Collapse
|