1
|
Caleb Bagley M, Garrard KP, Muddiman DC. The development and application of matrix assisted laser desorption electrospray ionization: The teenage years. MASS SPECTROMETRY REVIEWS 2023; 42:35-66. [PMID: 34028071 DOI: 10.1002/mas.21696] [Citation(s) in RCA: 31] [Impact Index Per Article: 31.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 04/20/2021] [Accepted: 04/21/2021] [Indexed: 05/24/2023]
Abstract
In the past 15 years, ambient ionization techniques have witnessed a significant incursion into the field of mass spectrometry imaging, demonstrating their ability to provide complementary information to matrix-assisted laser desorption ionization. Matrix-assisted laser desorption electrospray ionization is one such technique that has evolved since its first demonstrations with ultraviolet lasers coupled to Fourier transform-ion cyclotron resonance mass spectrometers to extensive use with infrared lasers coupled to orbitrap-based mass spectrometers. Concurrently, there have been transformative developments of this imaging platform due to the high level of control the principal group has retained over the laser technology, data acquisition software (RastirX), instrument communication, and image processing software (MSiReader). This review will discuss the developments of MALDESI since its first laboratory demonstration in 2005 to the most recent advances in 2021.
Collapse
Affiliation(s)
- Michael Caleb Bagley
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
| | - Kenneth P Garrard
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
- The Precision Engineering Consortium, North Carolina State University, Raleigh, North Carolina, USA
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, North Carolina, USA
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, North Carolina, USA
- Department of Plant and Microbial Biology, North Carolina State University, Raleigh, North Carolina, USA
| |
Collapse
|
2
|
DeLaney K, Phetsanthad A, Li L. ADVANCES IN HIGH-RESOLUTION MALDI MASS SPECTROMETRY FOR NEUROBIOLOGY. MASS SPECTROMETRY REVIEWS 2022; 41:194-214. [PMID: 33165982 PMCID: PMC8106695 DOI: 10.1002/mas.21661] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Accepted: 09/13/2020] [Indexed: 05/08/2023]
Abstract
Research in the field of neurobiology and neurochemistry has seen a rapid expansion in the last several years due to advances in technologies and instrumentation, facilitating the detection of biomolecules critical to the complex signaling of neurons. Part of this growth has been due to the development and implementation of high-resolution Fourier transform (FT) mass spectrometry (MS), as is offered by FT ion cyclotron resonance (FTICR) and Orbitrap mass analyzers, which improves the accuracy of measurements and helps resolve the complex biological mixtures often analyzed in the nervous system. The coupling of matrix-assisted laser desorption/ionization (MALDI) with high-resolution MS has drastically expanded the information that can be obtained with these complex samples. This review discusses notable technical developments in MALDI-FTICR and MALDI-Orbitrap platforms and their applications toward molecules in the nervous system, including sequence elucidation and profiling with de novo sequencing, analysis of post-translational modifications, in situ analysis, key advances in sample preparation and handling, quantitation, and imaging. Notable novel applications are also discussed to highlight key developments critical to advancing our understanding of neurobiology and providing insight into the exciting future of this field. © 2020 John Wiley & Sons Ltd. Mass Spec Rev.
Collapse
Affiliation(s)
- Kellen DeLaney
- Department of Chemistry, University of Wisconsin-Madison, 1101 University Avenue, Madison, WI 53706, USA
| | - Ashley Phetsanthad
- Department of Chemistry, University of Wisconsin-Madison, 1101 University Avenue, Madison, WI 53706, USA
| | - Lingjun Li
- Department of Chemistry, University of Wisconsin-Madison, 1101 University Avenue, Madison, WI 53706, USA
- School of Pharmacy, University of Wisconsin-Madison, 777 Highland Avenue, Madison, WI 53705, USA
| |
Collapse
|
3
|
Knizner KT, Bagley MC, Garrard KP, Hauschild JP, Pu F, Elsen NL, Williams JD, Muddiman DC. Optimized C-Trap Timing of an Orbitrap 240 Mass Spectrometer for High-Throughput Screening and Native MS by IR-MALDESI. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:328-334. [PMID: 35073091 PMCID: PMC9944060 DOI: 10.1021/jasms.1c00319] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Infrared matrix-assisted laser desorption ionization (IR-MALDESI) is a hybrid mass spectrometry ionization source that combines the benefits of electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) making it a great analytical tool for high-throughput screening (HTS) analyses. IR-MALDESI is coupled to an Orbitrap Exploris 240 mass spectrometer that utilizes a bent quadrupole (C-trap) to inject accumulated ions into the high-field Orbitrap mass analyzer. Here, we present a study on the optimized C-trap timing for HTS analyses by IR-MALDESI mass spectrometry. The timing between initial ion generation and the C-trap opening time was optimized to reduce unnecessary ambient ion accumulation in the mass spectrometer. The time in which the C-trap was held open, the ion accumulation time, was further optimized to maximize the accumulation of analyte ions generated using IR-MALDESI. The resulting C-trap opening scheme benefits small-molecule HTS analyses by IR-MALDESI by maximizing target ion abundances, minimizing ambient ion abundances, and minimizing the total analysis time per sample. The proposed C-trap timing scheme for HTS does not translate to large molecules; a NIST monoclonal antibody standard reference material was analyzed to demonstrate that larger analytes require longer ion accumulation times and that IR-MALDESI can measure intact antibodies in their native state.
Collapse
Affiliation(s)
- Kevan T. Knizner
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
| | - Michael C. Bagley
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
| | - Kenneth P. Garrard
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
- Precision Engineering Consortium, North Carolina State University, Raleigh, NC 27695, USA
| | | | - Fan Pu
- Drug Discovery Science and Technology, AbbVie Inc., North Chicago, Illinois 60064, USA
| | - Nathaniel L. Elsen
- Drug Discovery Science and Technology, AbbVie Inc., North Chicago, Illinois 60064, USA
| | - Jon D. Williams
- Drug Discovery Science and Technology, AbbVie Inc., North Chicago, Illinois 60064, USA
| | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC 27695, USA
| |
Collapse
|
4
|
Bagley MC, Muddiman DC. Investigations of β-carotene radical cation formation in infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI). RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35:e9133. [PMID: 34038981 DOI: 10.1002/rcm.9133] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Revised: 05/15/2021] [Accepted: 05/24/2021] [Indexed: 06/12/2023]
Abstract
RATIONALE Radical cationization of endogenous hydrocarbons in cherry tomatoes was previously reported using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI), a mass spectrometry imaging technique that operates at ambient conditions and requires no sample derivatization. Due to the surprising nature of this odd-electron ionization, subsequent experiments were performed on β-carotene to determine the amount of radical cationization across different sampling conditions. METHODS β-Carotene was analyzed across a variety of sample states using IR-MALDESI followed by Orbitrap mass spectrometric analysis: first, as a standard in ethanol in a well plate; second, as particulates on printer paper; and third, as particulates covered by an ice matrix. These techniques were also performed with a β-carotene standard either in solution with a reducing agent (ascorbic acid) or with ascorbic acid in the electrospray solution. RESULTS Tandem mass spectrometry confirmed the presence of the radical cation of β-carotene by comparing fragments against NIST and METLIN databases. It was always analyzed as a radical cation when sampled from solution, where ascorbic acid increased radical cation abundance when in solution with β-carotene. Mixed-mode ionization between radical cationization and proton adduction was observed from dried particulates using IR-MALDESI. CONCLUSIONS There are several potential mechanisms for β-carotene radical cationization prior to IR-MALDESI analysis, with multiphoton ionization, thermal degradation, and/or reaction with oxygen appearing to be the most logical explanations. Furthermore, although not the primary cause, changing certain aspects of sample conditions can result in significant mixed-mode ionization with competing protonation.
Collapse
Affiliation(s)
- M Caleb Bagley
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
- Department of Plant and Microbial Biology, North Carolina State University, Raleigh, NC, 27695, USA
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC, 27695, USA
| |
Collapse
|
5
|
Rivera ES, Djambazova KV, Neumann EK, Caprioli RM, Spraggins JM. Integrating ion mobility and imaging mass spectrometry for comprehensive analysis of biological tissues: A brief review and perspective. JOURNAL OF MASS SPECTROMETRY : JMS 2020; 55:e4614. [PMID: 32955134 PMCID: PMC8211109 DOI: 10.1002/jms.4614] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 06/27/2020] [Accepted: 07/02/2020] [Indexed: 05/02/2023]
Abstract
Imaging mass spectrometry (IMS) technologies are capable of mapping a wide array of biomolecules in diverse cellular and tissue environments. IMS has emerged as an essential tool for providing spatially targeted molecular information due to its high sensitivity, wide molecular coverage, and chemical specificity. One of the major challenges for mapping the complex cellular milieu is the presence of many isomers and isobars in these samples. This challenge is traditionally addressed using orthogonal liquid chromatography (LC)-based analysis, though, common approaches such as chromatography and electrophoresis are not able to be performed at timescales that are compatible with most imaging applications. Ion mobility offers rapid, gas-phase separations that are readily integrated with IMS workflows in order to provide additional data dimensionality that can improve signal-to-noise, dynamic range, and specificity. Here, we highlight recent examples of ion mobility coupled to IMS and highlight their importance to the field.
Collapse
Key Words
- IMS
- desorption electrospray ionization, DESI
- drift tube ion mobility spectrometry, DTIMS
- high-field asymmetric waveform ion mobility, FAIMS
- imaging mass spectrometry
- infrared matrix-assisted laser desorption electrospray ionization, IR-MALDESI
- ion mobility
- laser ablation electrospray ionization, LAESI
- lipids
- liquid extraction surface analysis, LESA
- liquid microjunction, (LMJ)
- matrix-assisted laser desorption electrospray ionization, MALDI
- metabolites
- proteins
- tissue analysis
- trapped ion mobility spectrometry, TIMS
- travelling wave ion mobility spectrometry, TWIMS
Collapse
Affiliation(s)
- Emilio S. Rivera
- Department of Biochemistry, Vanderbilt University, 607 Light Hall, Nashville, TN 37205, USA
- Mass Spectrometry Research Center, Vanderbilt University, 465 21 Ave S #9160, Nashville, TN 37235, USA
| | - Katerina V. Djambazova
- Mass Spectrometry Research Center, Vanderbilt University, 465 21 Ave S #9160, Nashville, TN 37235, USA
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, Station B 351822, Nashville, TN 37235, USA
| | - Elizabeth K. Neumann
- Department of Biochemistry, Vanderbilt University, 607 Light Hall, Nashville, TN 37205, USA
- Mass Spectrometry Research Center, Vanderbilt University, 465 21 Ave S #9160, Nashville, TN 37235, USA
| | - Richard M. Caprioli
- Department of Biochemistry, Vanderbilt University, 607 Light Hall, Nashville, TN 37205, USA
- Mass Spectrometry Research Center, Vanderbilt University, 465 21 Ave S #9160, Nashville, TN 37235, USA
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, Station B 351822, Nashville, TN 37235, USA
- Department of Pharmacology, Vanderbilt University, 2220 Pierce Avenue, Nashville, TN 37232, USA
- Department of Medicine, Vanderbilt University, 465 21 Ave S #9160, Nashville, TN 37235, USA
| | - Jeffrey M. Spraggins
- Department of Biochemistry, Vanderbilt University, 607 Light Hall, Nashville, TN 37205, USA
- Mass Spectrometry Research Center, Vanderbilt University, 465 21 Ave S #9160, Nashville, TN 37235, USA
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, Station B 351822, Nashville, TN 37235, USA
| |
Collapse
|
6
|
Bagley MC, Pace CL, Ekelöf M, Muddiman DC. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) mass spectrometry imaging analysis of endogenous metabolites in cherry tomatoes. Analyst 2020; 145:5516-5523. [PMID: 32602477 PMCID: PMC7423647 DOI: 10.1039/d0an00818d] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
We report the spatially resolved metabolic profiling of cherry tomatoes using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI), a mass spectrometry imaging (MSI) technique that operates at ambient conditions and requires no sample derivatization. Tomatoes were flash frozen, cryosectioned and imaged with adequate spatial resolution to distinguish between the major tissue structures of a tomato including the skin, mesocarp, endocarp, locular tissue, septum, placenta, seed and seed coating. Metabolites were imaged from 100-1200 m/z, enabling significant coverage of a diverse array of metabolites including amino acids and lipids along with the major secondary metabolite classes: terpenes, phenolics, glycosides, and alkaloids. During the metabolic profiling, we found endogenous carotenoid hydrocarbons, namely lycopene or its structural isomer β-carotene, ionized as radical cations. To our knowledge, this is the first demonstration of ionizing hydrocarbons in the MSI field.
Collapse
Affiliation(s)
- M Caleb Bagley
- FTMS Laboratory for Human Health Research, Department of Chemistry, USA.
| | - Crystal L Pace
- FTMS Laboratory for Human Health Research, Department of Chemistry, USA.
| | - Måns Ekelöf
- FTMS Laboratory for Human Health Research, Department of Chemistry, USA.
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, USA. and Department of Plant and Microbial Biology, USA and Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC 27695, USA
| |
Collapse
|
7
|
Recent advances of ambient mass spectrometry imaging for biological tissues: A review. Anal Chim Acta 2020; 1117:74-88. [DOI: 10.1016/j.aca.2020.01.052] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 01/21/2020] [Accepted: 01/22/2020] [Indexed: 12/30/2022]
|
8
|
Bagley MC, Stepanova AN, Ekelöf M, Alonso JM, Muddiman DC. Development of a relative quantification method for infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging of Arabidopsis seedlings. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34:e8616. [PMID: 31658400 DOI: 10.1002/rcm.8616] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2019] [Revised: 09/15/2019] [Accepted: 09/30/2019] [Indexed: 06/10/2023]
Abstract
RATIONALE Mass spectrometry imaging of young seedlings is an invaluable tool in understanding how mutations affect metabolite accumulation in plant development. However, due to numerous biological considerations, established methods for the relative quantification of analytes using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) mass spectrometry imaging are not viable options. In this study, we report a method for the quantification of auxin-related compounds using stable-isotope-labelled (SIL) indole-3-acetic acid (IAA) doped into agarose substrate. METHODS Wild-type Arabidopsis thaliana seedlings, sur2 and wei8 tar2 loss-of-function mutants, and YUC1 gain-of-function line were grown for 3 days in the dark in standard growth medium. SIL-IAA was doped into a 1% low-melting-point agarose gel and seedlings were gently laid on top for IR-MALDESI imaging with Orbitrap mass spectrometry analysis. Relative quantification was performed post-acquisition by normalization of auxin-related compounds to SIL-IAA in the agarose. Amounts of auxin-related compounds were compared between genotypes to distinguish the effects of the mutations on the accumulation of indolic metabolites of interest. RESULTS IAA added to agarose was found to remain stable, with repeatability and abundance features of IAA comparable with those of other compounds used in other methods for relative quantification in IR-MALDESI analyses. Indole-3-acetaldoxime was increased in sur2 mutants compared with wild-type and other mutants. Other auxin-related metabolites were either below the limits of quantification or successfully quantified but showing little difference among mutants. CONCLUSIONS Agarose was shown to be an appropriate sampling surface for IR-MALDESI mass spectrometry imaging of Arabidopsis seedlings. SIL-IAA doping of agarose was demonstrated as a viable technique for relative quantification of metabolites in live seedlings or tissues with similar biological considerations.
Collapse
Affiliation(s)
- M Caleb Bagley
- Department of Chemistry, FTMS Laboratory for Human Health Research, North Carolina State University, Raleigh, NC, 27695, USA
| | - Anna N Stepanova
- Department of Plant and Microbial Biology, North Carolina State University, Raleigh, NC, 27695, USA
- Program in Genetics, North Carolina State University, Raleigh, NC, 27695, USA
| | - Måns Ekelöf
- Department of Chemistry, FTMS Laboratory for Human Health Research, North Carolina State University, Raleigh, NC, 27695, USA
| | - Jose M Alonso
- Department of Plant and Microbial Biology, North Carolina State University, Raleigh, NC, 27695, USA
- Program in Genetics, North Carolina State University, Raleigh, NC, 27695, USA
| | - David C Muddiman
- Department of Chemistry, FTMS Laboratory for Human Health Research, North Carolina State University, Raleigh, NC, 27695, USA
- Department of Plant and Microbial Biology, North Carolina State University, Raleigh, NC, 27695, USA
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC, 27695, USA
| |
Collapse
|
9
|
Ekelöf M, Dodds J, Khodjaniyazova S, Garrard KP, Baker ES, Muddiman DC. Coupling IR-MALDESI with Drift Tube Ion Mobility-Mass Spectrometry for High-Throughput Screening and Imaging Applications. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:642-650. [PMID: 31971795 PMCID: PMC7263366 DOI: 10.1021/jasms.9b00081] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Because of its high degree of selectivity and chemical resolution, mass spectrometry (MS) is rapidly becoming the analytical method of choice for high-throughput evaluations and clinical diagnostics. While advances in MS resolving power have increased by an order of magnitude over the past decade, advances in sample introduction are still needed for high-throughput screening applications where the time frame of chromatographic separation would limit the duty cycle. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is an ambient ionization source that has been shown to be applicable for direct analyses and mass spectrometry imaging (MSI) of complex biological samples in a high-throughput manner. To increase a range of detectable features in IR-MALDESI experiments, we integrated the home-built ion source with a commercially available drift tube ion mobility spectrometer-mass spectrometer (IMS-MS) and analyzed small polar molecules, lipids, carbohydrates, and intact proteins. We also describe in detail how the pulsed ionization source was synchronized with IMS-MS.
Collapse
Affiliation(s)
- Måns Ekelöf
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - James Dodds
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Sitora Khodjaniyazova
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Kenneth P Garrard
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
- Precision Engineering Consortium, Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina 27606, United States
| | - Erin S Baker
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, North Carolina 27695, United States
| |
Collapse
|
10
|
Caleb Bagley M, Ekelöf M, Muddiman DC. Determination of Optimal Electrospray Parameters for Lipidomics in Infrared-Matrix-Assisted Laser Desorption Electrospray Ionization Mass Spectrometry Imaging. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:319-325. [PMID: 32031399 PMCID: PMC10861021 DOI: 10.1021/jasms.9b00063] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Infrared matrix-assisted laser desorption ionization (IR-MALDESI) is an ambient mass spectrometry imaging (MSI) technique that relies on electrospray ionization (ESI) for ion generation of desorbed neutrals. Although many mechanisms in IR-MALDESI have been studied in depth, there has not yet been a comprehensive study of how the ESI parameters change the profiles of tissue specific lipids. Acetonitrile (ACN)/water and methanol (MeOH)/water solvent systems and compositions were varied across a series of applied ESI voltages during IR-MALDESI analysis of rat liver tissue. Gradients of 12 min were run from 5 to 95% organic solvent in both positive and negative polarities across 11 voltages between 2.25 and 4.5 kV. These experiments informed longer gradients (25-30 min) across shorter solvent gradient ranges with fewer voltages. Optimal ESI parameters for lipidomics were determined by the number and abundance of detected lipids and the relative proportion of background ions. In positive polarity, the best solvent composition was 60-75% ACN/40-25% H2O with 0.2% formic acid at 3.2 kV applied voltage. The best parameters for negative polarity analysis are 45-55% ACN/55-45% H2O with 1 mM of acetic acid for voltages between 2.25 and 3.2 kV. Using these defined parameters, IR-MALDESI positive polarity lipidomics studies can increase lipid abundances 3-fold, with 15% greater coverage, while an abundance increase of 1.5-fold and 10% more coverage can be achieved relative to commonly used parameters in negative polarity.
Collapse
Affiliation(s)
- M. Caleb Bagley
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695
| | - Måns Ekelöf
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695
| | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC 27695
| |
Collapse
|
11
|
Feider CL, Krieger A, DeHoog RJ, Eberlin LS. Ambient Ionization Mass Spectrometry: Recent Developments and Applications. Anal Chem 2019; 91:4266-4290. [PMID: 30790515 PMCID: PMC7444024 DOI: 10.1021/acs.analchem.9b00807] [Citation(s) in RCA: 278] [Impact Index Per Article: 55.6] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Clara L. Feider
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Anna Krieger
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Rachel J. DeHoog
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Livia S. Eberlin
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| |
Collapse
|
12
|
Nazari M, Ekelöf M, Khodjaniyazova S, Elsen NL, Williams JD, Muddiman DC. Direct screening of enzyme activity using infrared matrix-assisted laser desorption electrospray ionization. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2017; 31:1868-1874. [PMID: 28841760 PMCID: PMC5653407 DOI: 10.1002/rcm.7971] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Revised: 08/13/2017] [Accepted: 08/19/2017] [Indexed: 05/08/2023]
Abstract
RATIONALE High-throughput screening (HTS) is a critical step in the drug discovery process. However, most mass spectrometry (MS)-based HTS methods require sample cleanup steps prior to analysis. In this work we present the utility of infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) for monitoring an enzymatic reaction directly from a biological buffer system with no sample cleanup and at high throughput. METHODS IR-MALDESI was used to directly analyze reaction mixtures from a well plate at different time points after reaction initiation. The percent conversion of precursors to products was used to screen the enzyme activity. The reaction was performed with two different concentrations of precursors and enzyme in order to assess the dynamic range of the assay. Eventually, a pseudo-HTS study was designed to investigate the utility of IR-MALDESI screening enzyme activity in a high-throughput manner. RESULTS IR-MALDESI was able to readily monitor the activity of IDH1 over time at two different concentrations of precursors and enzyme. The calculated Z-factors of 0.65 and 0.41 confirmed the suitability of the developed method for screening enzyme activity in HTS manner. Finally, in a single-blind pseudo-HTS analysis IR-MALDESI was able to correctly predict the identity of all samples, where 8/10 samples were identified with high confidence and the other two samples with lower confidence. CONCLUSIONS The enzymatic activity of IDH1 was screened by directly analyzing the reaction content from the buffer in well plates with no sample cleanup steps. This proof-of-concept study demonstrates the robustness of IR-MALDESI for direct analysis of enzymatic reactions from biological buffers with no sample cleanup and its immense potential for HTS applications.
Collapse
Affiliation(s)
- Milad Nazari
- W. M. Keck FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695
| | - Måns Ekelöf
- W. M. Keck FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695
| | - Sitora Khodjaniyazova
- W. M. Keck FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695
| | | | | | - David C. Muddiman
- W. M. Keck FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695
| |
Collapse
|