1
|
Bavi O, Zhou Z, Bavi N, Mehdi Vaez Allaei S, Cox CD, Martinac B. Asymmetric effects of amphipathic molecules on mechanosensitive channels. Sci Rep 2022; 12:9976. [PMID: 35705645 PMCID: PMC9200802 DOI: 10.1038/s41598-022-14446-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Accepted: 06/06/2022] [Indexed: 12/30/2022] Open
Abstract
Mechanosensitive (MS) ion channels are primary transducers of mechanical force into electrical and/or chemical intracellular signals. Many diverse MS channel families have been shown to respond to membrane forces. As a result of this intimate relationship with the membrane and proximal lipids, amphipathic compounds exert significant effects on the gating of MS channels. Here, we performed all-atom molecular dynamics (MD) simulations and employed patch-clamp recording to investigate the effect of two amphipaths, Fluorouracil (5-FU) a chemotherapy agent, and the anaesthetic trifluoroethanol (TFE) on structurally distinct mechanosensitive channels. We show that these amphipaths have a profound effect on the bilayer order parameter as well as transbilayer pressure profile. We used bacterial mechanosensitive channels (MscL/MscS) and a eukaryotic mechanosensitive channel (TREK-1) as force-from-lipids reporters and showed that these amphipaths have differential effects on these channels depending on the amphipaths' size and shape as well as which leaflet of the bilayer they incorporate into. 5-FU is more asymmetric in shape and size than TFE and does not penetrate as deep within the bilayer as TFE. Thereby, 5-FU has a more profound effect on the bilayer and channel activity than TFE at much lower concentrations. We postulate that asymmetric effects of amphipathic molecules on mechanosensitive membrane proteins through the bilayer represents a general regulatory mechanism for these proteins.
Collapse
Affiliation(s)
- Omid Bavi
- grid.444860.a0000 0004 0600 0546Department of Mechanical and Aerospace Engineering, Shiraz University of Technology, Shiraz, Iran
| | - Zijing Zhou
- grid.1057.30000 0000 9472 3971Molecular Cardiology and Biophysics Division, Victor Chang Cardiac Research Institute, Darlinghurst, NSW 2010 Australia
| | - Navid Bavi
- grid.170205.10000 0004 1936 7822Department of Biochemistry and Molecular Biology, The University of Chicago, Chicago, IL USA
| | - S. Mehdi Vaez Allaei
- grid.46072.370000 0004 0612 7950Department of Physics, University of Tehran, 1439955961 Tehran, Iran
| | - Charles D. Cox
- grid.1057.30000 0000 9472 3971Molecular Cardiology and Biophysics Division, Victor Chang Cardiac Research Institute, Darlinghurst, NSW 2010 Australia ,grid.1005.40000 0004 4902 0432Faculty of Medicine, St Vincent’s Clinical School, University of New South Wales, Darlinghurst, NSW 2010 Australia
| | - B. Martinac
- grid.1057.30000 0000 9472 3971Molecular Cardiology and Biophysics Division, Victor Chang Cardiac Research Institute, Darlinghurst, NSW 2010 Australia ,grid.1005.40000 0004 4902 0432Faculty of Medicine, St Vincent’s Clinical School, University of New South Wales, Darlinghurst, NSW 2010 Australia
| |
Collapse
|
2
|
Life with Bacterial Mechanosensitive Channels, from Discovery to Physiology to Pharmacological Target. Microbiol Mol Biol Rev 2020; 84:84/1/e00055-19. [PMID: 31941768 DOI: 10.1128/mmbr.00055-19] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
General principles in biology have often been elucidated from the study of bacteria. This is true for the bacterial mechanosensitive channel of large conductance, MscL, the channel highlighted in this review. This channel functions as a last-ditch emergency release valve discharging cytoplasmic solutes upon decreases in osmotic environment. Opening the largest gated pore, MscL passes molecules up to 30 Å in diameter; exaggerated conformational changes yield advantages for study, including in vivo assays. MscL contains structural/functional themes that recur in higher organisms and help elucidate how other, structurally more complex, channels function. These features of MscL include (i) the ability to directly sense, and respond to, biophysical changes in the membrane, (ii) an α helix ("slide helix") or series of charges ("knot in a rope") at the cytoplasmic membrane boundary to guide transmembrane movements, and (iii) important subunit interfaces that, when disrupted, appear to cause the channel to gate inappropriately. MscL may also have medical applications: the modality of the MscL channel can be changed, suggesting its use as a triggered nanovalve in nanodevices, including those for drug targeting. In addition, recent studies have shown that the antibiotic streptomycin opens MscL and uses it as one of the primary paths to the cytoplasm. Moreover, the recent identification and study of novel specific agonist compounds demonstrate that the channel is a valid drug target. Such compounds may serve as novel-acting antibiotics and adjuvants, a way of permeabilizing the bacterial cell membrane and, thus, increasing the potency of commonly used antibiotics.
Collapse
|
3
|
Abstract
Mechanosensitive (MS) channels protect bacteria against hypo-osmotic shock and fulfil additional functions. Hypo-osmotic shock leads to high turgor pressure that can cause cell rupture and death. MS channels open under these conditions and release unspecifically solutes and consequently the turgor pressure. They can recognise the raised pressure via the increased tension in the cell membrane. Currently, a better understanding how MS channels can sense tension on molecular level is developing because the interaction of the lipid bilayer with the channel is being investigated in detail. The MS channel of large conductance (MscL) and of small conductance (MscS) have been distinguished and studied in molecular detail. In addition, larger channels were found that contain a homologous region corresponding to MscS so that MscS represents a family of channels. Often several members of this family are present in a species. The importance of this family is underlined by the fact that members can be found not only in bacteria but also in higher organisms. While MscL and MscS have been studied for years in particular by electrophysiology, mutagenesis, molecular dynamics, X-ray crystallography and other biophysical techniques, only recently more details are emerging about other members of the MscS-family.
Collapse
|
4
|
Zhu L, Wu J, Liu L, Liu Y, Yan Y, Cui Q, Chen X. Gating mechanism of mechanosensitive channel of large conductance: a coupled continuum mechanical-continuum solvation approach. Biomech Model Mechanobiol 2016; 15:1557-1576. [PMID: 27009075 DOI: 10.1007/s10237-016-0783-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2015] [Accepted: 03/09/2016] [Indexed: 10/22/2022]
Abstract
Gating transition of the mechanosensitive channel of large conductance (MscL) represents a good example of important biological processes that are difficult to describe using atomistic simulations due to the large (submicron) length scale and long (millisecond) time scale. Here we develop a novel computational framework that tightly couples continuum mechanics with continuum solvation models to study the detailed gating behavior of E. coli-MscL. The components of protein molecules are modeled by continuum elements that properly describe their shape, material properties and physicochemical features (e.g., charge distribution). The lipid membrane is modeled as a three-layer material in which the lipid head group and tail regions are treated separately, taking into account the fact that fluidic lipid bilayers do not bear shear stress. Coupling between mechanical and chemical responses of the channel is realized by an iterative integration of continuum mechanics (CM) modeling and continuum solvation (CS) computation. Compared to previous continuum mechanics studies, the present model is capable of capturing the most essential features of the gating process in a much more realistic fashion: due mainly to the apolar solvation contribution, the membrane tension for full opening of MscL is reduced substantially to the experimental measured range. Moreover, the pore size stabilizes constantly during gating because of the intricate interactions of the multiple components of the system, implying the mechanism for sub-conducting states of MscL gating. A significant fraction ([Formula: see text]2/3) of the gating membrane strain is required to reach the first sub-conducting state of our model, which is featured with a relative conductance of 0.115 to the fully opened state. These trends agree well with experimental observations. We anticipate that the coupled CM/CS modeling framework is uniquely suited for the analysis of many biomolecules and their assemblies under external mechanical stimuli.
Collapse
Affiliation(s)
- Liangliang Zhu
- International Center for Applied Mechanics, State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace, Xi'an Jiaotong University, Xi'an, 710049, People's Republic of China.,Columbia Nanomechanics Research Center, Department of Earth and Environmental Engineering, Columbia University, New York, NY, 10027, USA
| | - Jiazhong Wu
- International Center for Applied Mechanics, State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace, Xi'an Jiaotong University, Xi'an, 710049, People's Republic of China
| | - Ling Liu
- Department of Mechanical and Aerospace Engineering, Utah State University, Logan, UT, 84322, USA
| | - Yilun Liu
- International Center for Applied Mechanics, State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace, Xi'an Jiaotong University, Xi'an, 710049, People's Republic of China
| | - Yuan Yan
- International Center for Applied Mechanics, State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace, Xi'an Jiaotong University, Xi'an, 710049, People's Republic of China
| | - Qiang Cui
- Department of Chemistry and Theoretical Chemistry Institute, University of Wisconsin-Madison, Madison, WI, 53706, USA
| | - Xi Chen
- Columbia Nanomechanics Research Center, Department of Earth and Environmental Engineering, Columbia University, New York, NY, 10027, USA.
| |
Collapse
|
5
|
Iscla I, Wray R, Eaton C, Blount P. Scanning MscL Channels with Targeted Post-Translational Modifications for Functional Alterations. PLoS One 2015; 10:e0137994. [PMID: 26368283 PMCID: PMC4569298 DOI: 10.1371/journal.pone.0137994] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2015] [Accepted: 08/25/2015] [Indexed: 01/20/2023] Open
Abstract
Mechanosensitive channels are present in all living organisms and are thought to underlie the senses of touch and hearing as well as various important physiological functions like osmoregulation and vasoregulation. The mechanosensitive channel of large conductance (MscL) from Escherichia coli was the first protein shown to encode mechanosensitive channel activity and serves as a paradigm for how a channel senses and responds to mechanical stimuli. MscL plays a role in osmoprotection in E. coli, acting as an emergency release valve that is activated by membrane tension due to cell swelling after an osmotic down-shock. Using an osmotically fragile strain in an osmotic down-shock assay, channel functionality can be directly determined in vivo. In addition, using thiol reagents and expressed MscL proteins with a single cysteine substitution, we have shown that targeted post-translational modifications can be performed, and that any alterations that lead to dysfunctional proteins can be identified by this in vivo assay. Here, we present the results of such a scan performed on 113 MscL cysteine mutants using five different sulfhydryl-reacting probes to confer different charges or hydrophobicity to each site. We assessed which of these targeted modifications affected channel function and the top candidates were further studied using patch clamp to directly determine how channel activity was affected. This comprehensive screen has identified many residues that are critical for channel function as well as highlighted MscL domains and residues that undergo the most drastic environmental changes upon gating.
Collapse
Affiliation(s)
- Irene Iscla
- Department of Physiology, University of Texas Southwestern Medical Center at Dallas, Dallas, Texas, United States of America
| | - Robin Wray
- Department of Physiology, University of Texas Southwestern Medical Center at Dallas, Dallas, Texas, United States of America
| | - Christina Eaton
- Department of Physiology, University of Texas Southwestern Medical Center at Dallas, Dallas, Texas, United States of America
| | - Paul Blount
- Department of Physiology, University of Texas Southwestern Medical Center at Dallas, Dallas, Texas, United States of America
- * E-mail:
| |
Collapse
|
6
|
Mechanical coupling of the multiple structural elements of the large-conductance mechanosensitive channel during expansion. Proc Natl Acad Sci U S A 2015; 112:10726-31. [PMID: 26261325 PMCID: PMC4553819 DOI: 10.1073/pnas.1503202112] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
The prokaryotic mechanosensitive channel of large conductance (MscL) is a pressure-relief valve protecting the cell from lysing during acute osmotic downshock. When the membrane is stretched, MscL responds to the increase of membrane tension and opens a nonselective pore to about 30 Å wide, exhibiting a large unitary conductance of ∼ 3 nS. A fundamental step toward understanding the gating mechanism of MscL is to decipher the molecular details of the conformational changes accompanying channel opening. By applying fusion-protein strategy and controlling detergent composition, we have solved the structures of an archaeal MscL homolog from Methanosarcina acetivorans trapped in the closed and expanded intermediate states. The comparative analysis of these two new structures reveals significant conformational rearrangements in the different domains of MscL. The large changes observed in the tilt angles of the two transmembrane helices (TM1 and TM2) fit well with the helix-pivoting model derived from the earlier geometric analyses based on the previous structures. Meanwhile, the periplasmic loop region transforms from a folded structure, containing an ω-shaped loop and a short β-hairpin, to an extended and partly disordered conformation during channel expansion. Moreover, a significant rotating and sliding of the N-terminal helix (N-helix) is coupled to the tilting movements of TM1 and TM2. The dynamic relationships between the N-helix and TM1/TM2 suggest that the N-helix serves as a membrane-anchored stopper that limits the tilts of TM1 and TM2 in the gating process. These results provide direct mechanistic insights into the highly coordinated movement of the different domains of the MscL channel when it expands.
Collapse
|
7
|
Zhong D, Yang LM, Blount P. Dynamics of protein-protein interactions at the MscL periplasmic-lipid interface. Biophys J 2014; 106:375-81. [PMID: 24461012 DOI: 10.1016/j.bpj.2013.12.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2013] [Revised: 11/13/2013] [Accepted: 12/03/2013] [Indexed: 12/27/2022] Open
Abstract
MscL, the highly conserved bacterial mechanosensitive channel of large conductance, is one of the best studied mechanosensors. It is a homopentameric channel that serves as a biological emergency release valve that prevents cell lysis from acute osmotic stress. We previously showed that the periplasmic region of the protein, particularly a single residue located at the TM1/periplasmic loop interface, F47 of Staphylococcus aureus and I49 of Escherichia coli MscL, plays a major role in both the open dwell time and mechanosensitivity of the channel. Here, we introduced cysteine mutations at these sites and found they formed disulfide bridges that decreased the channel open dwell time. By scanning a likely interacting domain, we also found that these sites could be disulfide trapped by addition of cysteine mutations in other locations within the periplasmic loop of MscL, and this also led to rapid channel kinetics. Together, the data suggest structural rearrangements and protein-protein interactions that occur within this region upon normal gating, and further suggest that locking portions of the channel into a transition state decreases the stability of the open state.
Collapse
Affiliation(s)
- Dalian Zhong
- Department of Physiology, UT Southwestern Medical Center at Dallas, Dallas, Texas
| | - Li-Min Yang
- Department of Physiology, UT Southwestern Medical Center at Dallas, Dallas, Texas
| | - Paul Blount
- Department of Physiology, UT Southwestern Medical Center at Dallas, Dallas, Texas.
| |
Collapse
|
8
|
Martinac B, Nomura T, Chi G, Petrov E, Rohde PR, Battle AR, Foo A, Constantine M, Rothnagel R, Carne S, Deplazes E, Cornell B, Cranfield CG, Hankamer B, Landsberg MJ. Bacterial mechanosensitive channels: models for studying mechanosensory transduction. Antioxid Redox Signal 2014; 20:952-69. [PMID: 23834368 DOI: 10.1089/ars.2013.5471] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
SIGNIFICANCE Sensations of touch and hearing are manifestations of mechanical contact and air pressure acting on touch receptors and hair cells of the inner ear, respectively. In bacteria, osmotic pressure exerts a significant mechanical force on their cellular membrane. Bacteria have evolved mechanosensitive (MS) channels to cope with excessive turgor pressure resulting from a hypo-osmotic shock. MS channel opening allows the expulsion of osmolytes and water, thereby restoring normal cellular turgor and preventing cell lysis. RECENT ADVANCES As biological force-sensing systems, MS channels have been identified as the best examples of membrane proteins coupling molecular dynamics to cellular mechanics. The bacterial MS channel of large conductance (MscL) and MS channel of small conductance (MscS) have been subjected to extensive biophysical, biochemical, genetic, and structural analyses. These studies have established MscL and MscS as model systems for mechanosensory transduction. CRITICAL ISSUES In recent years, MS ion channels in mammalian cells have moved into focus of mechanotransduction research, accompanied by an increased awareness of the role they may play in the pathophysiology of diseases, including cardiac hypertrophy, muscular dystrophy, or Xerocytosis. FUTURE DIRECTIONS A recent exciting development includes the molecular identification of Piezo proteins, which function as nonselective cation channels in mechanosensory transduction associated with senses of touch and pain. Since research on Piezo channels is very young, applying lessons learned from studies of bacterial MS channels to establishing the mechanism by which the Piezo channels are mechanically activated remains one of the future challenges toward a better understanding of the role that MS channels play in mechanobiology.
Collapse
Affiliation(s)
- Boris Martinac
- 1 Molecular Cardiology and Biophysics Division/Mechanosensory Biophysics Laboratory, Victor Chang Cardiac Research Institute , Darlinghurst, Australia
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Yang LM, Zhong D, Blount P. Chimeras reveal a single lipid-interface residue that controls MscL channel kinetics as well as mechanosensitivity. Cell Rep 2013; 3:520-7. [PMID: 23416054 DOI: 10.1016/j.celrep.2013.01.018] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2012] [Revised: 01/03/2013] [Accepted: 01/16/2013] [Indexed: 11/18/2022] Open
Abstract
MscL, the highly conserved bacterial mechanosensitive channel of large conductance, serves as an osmotic "emergency release valve," is among the best-studied mechanosensors, and is a paradigm of how a channel senses and responds to membrane tension. Although all homologs tested thus far encode channel activity, many show functional differences. We tested Escherichia coli and Staphylococcus aureus chimeras and found that the periplasmic region of the protein, particularly E. coli I49 and the equivalent S. aureus F47 at the periplasmic lipid-aqueous interface of the first transmembrane domain, drastically influences both the open dwell time and the threshold of channel opening. One mutant shows a severe hysteresis, confirming the importance of this residue in determining the energy barriers for channel gating. We propose that this site acts similarly to a spring for a clasp knife, adjusting the resistance for obtaining and stabilizing an open or closed channel structure.
Collapse
Affiliation(s)
- Li-Min Yang
- Department of Physiology, UT Southwestern Medical Center at Dallas, 5323 Harry Hines Boulevard, Dallas, TX 75390-9040, USA
| | | | | |
Collapse
|
10
|
Deplazes E, Louhivuori M, Jayatilaka D, Marrink SJ, Corry B. Structural investigation of MscL gating using experimental data and coarse grained MD simulations. PLoS Comput Biol 2012; 8:e1002683. [PMID: 23028281 PMCID: PMC3447979 DOI: 10.1371/journal.pcbi.1002683] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2012] [Accepted: 07/21/2012] [Indexed: 12/02/2022] Open
Abstract
The mechanosensitive channel of large conductance (MscL) has become a model system in which to understand mechanosensation, a process involved in osmoregulation and many other physiological functions. While a high resolution closed state structure is available, details of the open structure and the gating mechanism remain unknown. In this study we combine coarse grained simulations with restraints from EPR and FRET experiments to study the structural changes involved in gating with much greater level of conformational sampling than has previously been possible. We generated a set of plausible open pore structures that agree well with existing open pore structures and gating models. Most interestingly, we found that membrane thinning induces a kink in the upper part of TM1 that causes an outward motion of the periplasmic loop away from the pore centre. This previously unobserved structural change might present a new mechanism of tension sensing and might be related to a functional role in osmoregulation. Cells in biological organisms have to be able to respond to mechanical forces during processes such as touch, hearing, pain sensation and tissue growth. One way this is achieved is through mechanosensitive ion channels, membrane embedded proteins that initiate electrical signalling upon tension within the cell or cell membrane. The malfunction of such channels is also associated with a range of diseases including muscular dystrophy and cardiac arrhythmia. In this manuscript, we study in detail the mechanosensitive channel of large conductance (MscL) from bacteria, a model system in which to understand the principles of mechanosensation. Despite many years of investigative work the details of how the protein senses tension in the surrounding membrane remain unknown. By combining structural data from experiments with computer simulation we are able to model the open channel structure of the protein and report previously unobserved structural changes that might present a new mechanism of sensing tension. The methods developed in this paper are not limited to the study of mechanosensitive ion channels and may be useful in understanding the structure and function of other membrane proteins.
Collapse
Affiliation(s)
- Evelyne Deplazes
- School of Biomedical, Biomolecular and Chemical Sciences, The University of Western Australia, Perth, Australia
| | | | | | | | | |
Collapse
|
11
|
Balleza D. Mechanical properties of lipid bilayers and regulation of mechanosensitive function: from biological to biomimetic channels. Channels (Austin) 2012; 6:220-33. [PMID: 22790280 DOI: 10.4161/chan.21085] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
Material properties of lipid bilayers, including thickness, intrinsic curvature and compressibility regulate the function of mechanosensitive (MS) channels. This regulation is dependent on phospholipid composition, lateral packing and organization within the membrane. Therefore, a more complete framework to understand the functioning of MS channels requires insights into bilayer structure, thermodynamics and phospholipid structure, as well as lipid-protein interactions. Phospholipids and MS channels interact with each other mainly through electrostatic forces and hydrophobic matching, which are also crucial for antimicrobial peptides. They are excellent models for studying the formation and stabilization of membrane pores. Importantly, they perform equivalent responses as MS channels: (1) tilting in response to tension and (2) dissipation of osmotic gradients. Lessons learned from pore forming peptides could enrich our knowledge of mechanisms of action and evolution of these channels. Here, the current state of the art is presented and general principles of membrane regulation of mechanosensitive function are discussed.
Collapse
Affiliation(s)
- Daniel Balleza
- Unidad de Biofísica, CSIC, UPV/EHU, Universidad del País Vasco, Leioa, Spain.
| |
Collapse
|
12
|
Balleza D. Toward understanding protocell mechanosensation. ORIGINS LIFE EVOL B 2011; 41:281-304. [PMID: 21080073 DOI: 10.1007/s11084-010-9225-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2010] [Accepted: 10/20/2010] [Indexed: 01/11/2023]
Abstract
Mechanosensitive (MS) channels can prevent bacterial bursting during hypo-osmotic shocks by responding to increases in lateral tension at the membrane level through an integrated and coordinated opening mechanism. Mechanical regulation in protocells could have been one of the first mechanisms to evolve in order to preserve their integrity against changing environmental conditions. How has the rich functional diversity found in present cells been created throughout evolution, and what did the primordial MS channels look like? This review has been written with the aim of identifying which factors may have been important for the appearance of the first osmotic valve in a prebiotic context, and what this valve may have been like. It highlights the mechanical properties of lipid bilayers, the association of peptides as aggregates in membranes, and the conservation of sequence motifs as central aspects to understand the evolution of proteins that gate below the tension required for spontaneous pore formation and membrane rupture. The arguments developed here apply to both MscL and MscS homologs, but could be valid to mechano-susceptible proteins in general.
Collapse
Affiliation(s)
- Daniel Balleza
- Unidad de Biofísica, CSIC-UPV/EHU, Universidad del País Vasco, Barrio Sarriena s/n, Leioa, Spain.
| |
Collapse
|
13
|
Li S, Zhang X, Wang W. Coarse-grained model for mechanosensitive ion channels. J Phys Chem B 2010; 113:14431-8. [PMID: 19845409 DOI: 10.1021/jp9053567] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
In this work, a coarse-grained model for a kind of membrane protein, the mechanosensitive channel of small conductance (MscS), is proposed. The basic structure of the MscS is preserved when the protein is coarse-grained. For the coarse-grained model, the channels show two different states, namely the open and closed states, depending on the model parameters. Under the same membrane tension, the state of the ion channel is found to be critically determined by the protein structure, especially the length of the transmembrane alpha-helix. It is also found that for the protein with certain size, the gating transition occurs when the membrane tension is applied, resembling in a real mechanosensitive channel.
Collapse
Affiliation(s)
- Shuangyang Li
- Division of Molecular and Materials Simulation, Key Laboratory for Nanomaterials, Ministry of Education, Beijing University of Chemical Technology, Beijing 100029, China
| | | | | |
Collapse
|
14
|
Structure of a tetrameric MscL in an expanded intermediate state. Nature 2009; 461:120-4. [PMID: 19701184 PMCID: PMC2737600 DOI: 10.1038/nature08277] [Citation(s) in RCA: 89] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2009] [Accepted: 07/02/2009] [Indexed: 11/21/2022]
Abstract
The ability of cells to sense and respond to mechanical force underlies diverse processes such as touch and hearing in animals, gravitropism in plants, and bacterial osmoregulation1, 2. In bacteria, mechanosensation is mediated by the mechanosensitive channels of large (MscL), small (MscS), potassium-dependent (MscK), and mini (MscM) conductances. These channels act as “emergency relief valves” protecting bacteria from lysis upon acute osmotic downshock3. Among them, MscL has been intensively studied since the original identification and characterization 15 years ago by Kung and co-workers4. MscL is reversibly and directly gated by changes in membrane tension. In the open state, MscL forms a nonselective 3 nS-conductance channel which gates at tensions close to the lytic limit of the bacterial membrane. An earlier crystal structure at 3.5 Å resolution of a pentameric MscL from Mycobacterium tuberculosis (TbMscL) represents a closed-state or nonconducting conformation5, 6. MscL has a complex gating behaviour; it exhibits several intermediates between the closed and open states, including one putative nonconductive expanded state and at least three sub-conducting states7. Although our understanding of the closed5, 6 and open8-10 states of MscL has been increasing, little is known about the structures of the intermediate states despite their importance in elucidating the complete gating process of MscL. Here we present the crystal structure of a truncation mutant (Δ95-120) of MscL from Staphylococcus aureus (SaMscL-CΔ26) at 3.8 Å resolution. Strikingly, SaMscL-CΔ26 forms a tetrameric channel with both transmembrane (TM) helices tilted away from the membrane normal at angles close to that inferred for the open state9, likely corresponding to a nonconductive but partially expanded intermediate state.
Collapse
|
15
|
Hughes S, McBain S, Dobson J, El Haj AJ. Selective activation of mechanosensitive ion channels using magnetic particles. J R Soc Interface 2008; 5:855-63. [PMID: 18077244 PMCID: PMC2495030 DOI: 10.1098/rsif.2007.1274] [Citation(s) in RCA: 135] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
This study reports the preliminary development of a novel magnetic particle-based technique that permits the application of highly localized mechanical forces directly to specific regions of an ion-channel structure. We demonstrate that this approach can be used to directly and selectively activate a mechanosensitive ion channel of interest, namely TREK-1. It is shown that manipulation of particles targeted against the extended extracellular loop region of TREK-1 leads to changes in whole-cell currents consistent with changes in TREK-1 activity. Responses were absent when particles were coated with RGD (Arg-Gly-Asp) peptide or when magnetic fields were applied in the absence of magnetic particles. It is concluded that changes in whole-cell current are the result of direct force application to the extracellular loop region of TREK-1 and thus these results implicate this region of the channel structure in mechano-gating. It is hypothesized that the extended loop region of TREK-1 may act as a tension spring that acts to regulate sensitivity to mechanical forces, in a nature similar to that described for MscL. The development of a technique that permits the direct manipulation of mechanosensitive ion channels in real time without the need for pharmacological drugs has huge potential benefits not only for basic biological research of ion-channel gating mechanisms, but also potentially as a tool for the treatment of human diseases caused by ion-channel dysfunction.
Collapse
Affiliation(s)
- Steven Hughes
- Institute of Science and Technology in Medicine, Keele University School of Medicine, Stoke-on-Trent, Staffordshire ST4 7QB, UK
| | | | | | | |
Collapse
|
16
|
Debret G, Valadié H, Stadler AM, Etchebest C. New insights of membrane environment effects on MscL channel mechanics from theoretical approaches. Proteins 2007; 71:1183-96. [DOI: 10.1002/prot.21810] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
17
|
MscL: The Bacterial Mechanosensitive Channel of Large Conductance. MECHANOSENSITIVE ION CHANNELS, PART A 2007. [DOI: 10.1016/s1063-5823(06)58008-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
18
|
Meyer GR, Gullingsrud J, Schulten K, Martinac B. Molecular dynamics study of MscL interactions with a curved lipid bilayer. Biophys J 2006; 91:1630-7. [PMID: 16751236 PMCID: PMC1544281 DOI: 10.1529/biophysj.106.080721] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Mechanosensitivity is a ubiquitous sensory mechanism found in living organisms. The simplest known mechanotransducing mechanism is found in bacteria in the form of the mechanosensitive membrane channel of large conductance, MscL. This channel has been studied extensively using a variety of methods at a functional and structural level. The channel is gated by membrane tension in the lipid bilayer alone. It serves as a safety valve protecting bacterial cells against hypoosmotic shock. MscL of Escherichia coli embedded in bilayers composed of asymmetric amounts of single-tailed and double-tailed lipids has been shown to gate spontaneously, even in the absence of membrane tension. To gain insight into the effect of the lipid membrane composition and geometry on MscL structure, a fully solvated, all-atom model of MscL in a stress-free curved bilayer composed of double- and single-tailed lipids was studied using a 9.5-ns molecular dynamics simulation. The bilayer was modeled as a domed structure accommodating the asymmetric composition of the monolayers. During the course of the simulation a spontaneous restructuring of the periplasmic loops occurred, leading to interactions between one of the loops and phospholipid headgroups. Previous experimental studies of the role of the loops agree with the observation that opening starts with a restructuring of the periplasmic loop, suggesting an effect of the curved bilayer. Because of limited resources, only one simulation of the large system was performed. However, the results obtained suggest that through the geometry and composition of the bilayer the protein structure can be affected even on short timescales.
Collapse
Affiliation(s)
- Grischa R Meyer
- School of Medicine and Pharmacology, QEII Medical Centre, University of Western Australia, Crawley WA 6009, Australia.
| | | | | | | |
Collapse
|
19
|
Anishkin A, Kung C. Microbial mechanosensation. Curr Opin Neurobiol 2005; 15:397-405. [PMID: 16006117 DOI: 10.1016/j.conb.2005.06.002] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2005] [Accepted: 06/27/2005] [Indexed: 11/17/2022]
Abstract
Because bacterial mechanosensitive channels have been cloned, purified, crystallized and subjected to a genetic, biochemical and physical scrutiny, they have become the current structural models of mechanosensation to atomic detail. The key observation, supported by recent mutagenesis studies, is that these channels receive stretch force directly through the lipid bilayer at the interface levels bearing highest tension. Indeed, simulations of mechanosensitive channels steered by strategically applied bilayer stretch forces show channel opening. Our understanding of the gating energetics and trajectory are continually being refined by the combination of approaches applied. In addition, new microbial mechanosensitive channels from the TRP family have been characterized in yeasts. Unified by fundamental biophysical principles of gating, mechanosensitive channels provide broad insight into protein-membrane interactions and the role of hydrophobic hydration in gating.
Collapse
Affiliation(s)
- Andriy Anishkin
- Department of Biology, University of Maryland, College Park, MD 20742, USA.
| | | |
Collapse
|