1
|
Kouyoumdjian P. How the hip-spine relationship influences total hip arthroplasty. Orthop Traumatol Surg Res 2024; 110:103773. [PMID: 38000509 DOI: 10.1016/j.otsr.2023.103773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Accepted: 06/30/2023] [Indexed: 11/26/2023]
Abstract
INTRODUCTION Motion in the spine, pelvis and hips which make up the spinopelvic femoral complex (SPFC) implies mechanical relationships that help maintain trunk balance and optimize hip functionThe aim of this study was to understand the physiology of the SPFC and evaluate the dysfunctions of the SPFC and their implications for total hip arthroplasty considering the hip-spine relationship. METHODS A review of relevant and comprehensive studies on this subject is reported in order to highlight a pathophysiology that integrates the description of the evaluations of the spine-pelvic and hip parameters and recommendations for the kinematic planning of the THA procedure. The primary objective was to determine which type of hip-spine relationship has the highest risk for THA complications and to become proficient in selecting the priority surgical intervention when both the hip and spine are affected. Finally, this review attempted to assist hip surgeons with surgical technique, tools, implant selection, and goals of planning a THA that requires personalized kinematic alignment. Determine the influence of THA on these kinematics and the effect of stiffness of the lumbopelvic complex on the risk of THA failure. RESULTS When a person sits, the pelvis goes into retroversion and the acetabulum opens forward. This frees the femoral head and neck to allow hip flexion. The opposite - pelvic anteversion - occurs when a person stands. When pelvic mobility is limited, the hip must increase its range of motion to accommodate these posture changes. Disturbances in spinal and pelvic kinematics lead to abnormal hip function, which may contribute to complications following total hip arthroplasty (THA). CONCLUSION A precise evaluation of the parameters governing the SPFC must be taken into account in order to best optimize the placement and choice of THA implants. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Pascal Kouyoumdjian
- CHU de Nîmes, Faculté de Médecine Montpellier-Nîmes, Université Montpellier, Hôpital Carémeau, 4, place du Professeur-Robert-Debré, 30900 Nîmes, France.
| |
Collapse
|
2
|
Dubin JA, Westrich GH. Less groin pain with dual-mobility bearings versus fixed bearings in total hip arthroplasty. Hip Int 2024; 34:15-20. [PMID: 36891584 DOI: 10.1177/11207000231158722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/10/2023]
Abstract
INTRODUCTION The relationship between implant type, dual mobility (DM) or fixed bearing (FB), and postoperative groin pain remains unexplored. We examined the incidence of groin pain in DM implants and compare this to a cohort of FB THA patients. METHODS From 2006 to 2018, a single surgeon performed 875 DM THA and 856 FB THA procedures with 2.8-year and 3.1-year follow-up, respectively. Each patient received a questionnaire postoperatively and was asked if they had any groin pain (yes/no). Secondary measurements were implant characteristics such as head size, head offset, cup size, and cup-to-head ratio. Additional PROMs that were collected included: Veterans RAND 12 (VR-12), University of California Los Angeles (UCLA) activity score, Pain visual analogue scale (Pain VAS), and range of motion (ROM). RESULTS The incidence of groin pain was 2.3% in the DM THA cohort and 6.3% in the FB THA group (p < 0.001). Also, low head offset (⩽0 mm) had a significant odds ratio (1.61) for groin pain in both cohorts. There was no significant difference in terms of revision rate between the cohorts (2.5% vs. 3.3%, p = 0.39) at the latest follow up. CONCLUSIONS This study demonstrated a lower incidence of groin pain (2.3%) in patients with a DM bearing compared to a FB (6.3%) and a greater risk of groin pain with low head offset (<0 mm). As such, surgeons should try to recreate offset of the hip compared to the contralateral side to avoid groin pain.
Collapse
Affiliation(s)
- Jeremy A Dubin
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, NY, USA
| | - Geoffrey H Westrich
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
3
|
Wang JL, Wang J, Chen KN, Guo JQ, Xu XL, Guo CB. Designing customized temporomandibular fossa prosthesis based on envelope surface of condyle movement: validation via in silico musculoskeletal simulation. Front Bioeng Biotechnol 2023; 11:1273263. [PMID: 38026896 PMCID: PMC10644477 DOI: 10.3389/fbioe.2023.1273263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2023] [Accepted: 10/16/2023] [Indexed: 12/01/2023] Open
Abstract
Objective: This study presents an innovative articular fossa prosthesis generated by the envelope surface of condyle movement, and compares its mandible movements, muscle activities, and joint reaction forces with two temporomandibular joint (TMJ) prostheses using multibody musculoskeletal simulation. Methods: A healthy 23-year-old female was recruited for this study. Cone-beam computed tomographic (CBCT) was performed to reconstruct the mandibular bone geometry. A customized TMJ fossa prosthesis was designed based on the subject-specific envelope surface of condyle movement (ESCM). Mandibular kinematics and jaw-closing muscle electromyography (EMG) were simultaneously recorded during maximum jaw opening-closing movements. To validate our prosthesis design, a mandibular musculoskeletal model was established using flexible multibody dynamics and the obtained kinematics and EMG data. The Biomet fossa prosthesis and the ellipsoidal fossa prosthesis designed by imitating the lower limb prostheses were used for comparison. Simulations were performed to analyze the effects of different fossa prostheses on jaw opening-closing motions, mandibular muscle activation, and contact forces. Results: The maximum opening displacement for the envelope-based fossa prosthesis was greater than those for Biomet and ellipsoidal prostheses (36 mm, 35 mm, and 33 mm, respectively). The mandibular musculoskeletal model with ellipsoidal prosthesis led to dislocation near maximal jaw opening. Compared to Biomet, the envelope-based fossa reduced the digastric and lateral pterygoid activation at maximal jaw opening. It also reduced the maximal resistance to condylar sliding on the intact side by 63.2 N. Conclusion: A customized TMJ fossa prosthesis was successfully developed using the ESCM concept. Our study of musculoskeletal multibody modeling has highlighted its advantages and potential. The artificial fossa design successfully achieved a wider condylar range of motion. It also reduced the activation of jaw opening muscles on the affected side and resistance on the intact side. This study showed that an ESCM-based approach may be useful for optimizing TMJ fossa prostheses design.
Collapse
Affiliation(s)
- Jun-Lin Wang
- Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing Key Laboratory of Digital Stomatology, Research Center of Engineering and Technology for Computerized Dentistry, Ministry of Health, NMPA Key Laboratory for Dental Materials, Beijing, China
| | - Jing Wang
- Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing Key Laboratory of Digital Stomatology, Research Center of Engineering and Technology for Computerized Dentistry, Ministry of Health, NMPA Key Laboratory for Dental Materials, Beijing, China
| | - Ke-Nan Chen
- Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing Key Laboratory of Digital Stomatology, Research Center of Engineering and Technology for Computerized Dentistry, Ministry of Health, NMPA Key Laboratory for Dental Materials, Beijing, China
| | - Jian-Qiao Guo
- MOE Key Laboratory of Dynamics and Control of Flight Vehicle, School of Aerospace Engineering, Beijing Institute of Technology, Beijing, China
| | - Xiang-Liang Xu
- Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing Key Laboratory of Digital Stomatology, Research Center of Engineering and Technology for Computerized Dentistry, Ministry of Health, NMPA Key Laboratory for Dental Materials, Beijing, China
| | - Chuan-Bin Guo
- Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing Key Laboratory of Digital Stomatology, Research Center of Engineering and Technology for Computerized Dentistry, Ministry of Health, NMPA Key Laboratory for Dental Materials, Beijing, China
| |
Collapse
|
4
|
Unter Ecker N, Sangaletti R, Ohlmeier M, Akkaya M, Ekhtiari S, Klaber I, Gehrke T, Citak M. What is the rate of successful closed reduction of dislocated dual mobility cups following complex revision hip arthroplasty? Arch Orthop Trauma Surg 2023; 143:6439-6445. [PMID: 37000267 DOI: 10.1007/s00402-023-04826-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2022] [Accepted: 02/26/2023] [Indexed: 04/01/2023]
Abstract
PURPOSE The aim of this study was to assess the difference in success rates of closed reduction in septic and aseptic revision total hip arthroplasty (THA) performed with a dual mobility (DM) implant. Our objective was to answer the following questions: (1) Is there a difference in success rates of closed reduction between septic and aseptic revision THA with a DM implant? (2) Is closed or open reduction more successful in preventing re-dislocation? METHODS Between January 2009 and October 2021, 924 revisions were performed with a DM implant. All patients presenting to our institution with a dislocation following septic or aseptic revision THA using a cemented DM cup were included in this study. We analyzed 106 cases of dislocation in 74 patients. For all patients, we collected reason for revision, and classified index surgery as septic or aseptic. RESULTS Overall, 106 dislocations occurred (106/924, 11.5%). Thirty-nine cases (52.7%) had a dislocation after a septic exchange THA, while in 35 patients (47.3%), a dislocation occurred after an aseptic rTHA. In 29 patients (39.2%), successful closed reduction under general anesthesia was feasible, while the majority of cases required open reduction. In 31 of these patients (67.4%), open reduction was combined with a revision arthroplasty. CONCLUSIONS In case of DM cup dislocation, there is a low success rate of closed reduction. To prevent re-dislocation, total revision leads to a significantly reduced risk compared to open or closed reduction alone. Careful X-ray analysis for a halo sign showing intra-prosthetic DM cup dislocation is mandatory to avoid futile reduction attempts. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Niklas Unter Ecker
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstr. 2, 22767, Hamburg, Germany
| | - Rudy Sangaletti
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstr. 2, 22767, Hamburg, Germany
| | - Malte Ohlmeier
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstr. 2, 22767, Hamburg, Germany
| | - Mustafa Akkaya
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstr. 2, 22767, Hamburg, Germany
| | - Seper Ekhtiari
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstr. 2, 22767, Hamburg, Germany
| | - Ianiv Klaber
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstr. 2, 22767, Hamburg, Germany
| | - Thorsten Gehrke
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstr. 2, 22767, Hamburg, Germany
| | - Mustafa Citak
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstr. 2, 22767, Hamburg, Germany.
| |
Collapse
|
5
|
Ciriello V, La China R, Chirillo DF, Bianco G, Fusini F, Scarlato U, Albanese C, Bonzanini G, Banci L, Piovani L. Is Modular Dual Mobility Superior to Standard Bearings for Reducing Dislocation Risk after Primary Total Hip Arthroplasty? A Retrospective Comparative Multicenter Study. J Clin Med 2023; 12:4200. [PMID: 37445235 DOI: 10.3390/jcm12134200] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Revised: 06/01/2023] [Accepted: 06/19/2023] [Indexed: 07/15/2023] Open
Abstract
BACKGROUND Dual mobility (DM) has been proven to reduce dislocation risk after total hip arthroplasty (THA). In the last decade modular DM (modDM) constructs have been introduced to allow the use of DM articulation with standard cementless acetabular shells. However, clinical evidence of modDM effectiveness is still low in primary THA and concerns about implant-related complications are increasing. This retrospective comparative multicenter study is aimed to investigate if the dislocation rate after primary THA could be reduced with modDM in comparison to standard bearing (SB). METHODS 262 THAs were performed between 2017 and 2019, using SB (129 hips) or modDM (133) with the same cementless highly porous modular acetabular cup. Dislocations, complications and revisions were recorded and implant survival was analyzed. RESULTS At 2.5-year mean follow-up, dislocation occurred in 4 hips (3.1%) within the SB group while intraprosthetic dislocation in 2 hips (1.5%) within the modDM group (p = 0.44). Implant survivals with revision due to dislocation were 95.2% and 95.9% at 4-year follow-up for SB and modDM, respectively (p = 0.50). CONCLUSIONS modDM used in primary THA might reduce dislocation rate in comparison to SB, even in high-risk patients, however, caution is advocated due to specific intraprosthetic dislocation.
Collapse
Affiliation(s)
- Vincenzo Ciriello
- Ortopedia e Traumatologia, Ospedale Santa Croce e Carle, 12100 Cuneo, Italy
| | - Roberta La China
- Ortopedia e Traumatologia, Ospedale Santo Spirito, 15033 Casale Monferrato, Italy
| | | | - Giuseppe Bianco
- Ortopedia e Traumatologia, Ospedale Regina Montis Regalis, 12084 Mondovì, Italy
| | - Federico Fusini
- Ortopedia e Traumatologia, Ospedale Regina Montis Regalis, 12084 Mondovì, Italy
| | - Ugo Scarlato
- Ortopedia e Traumatologia, Ospedale Civile, 10015 Ivrea, Italy
| | - Carlo Albanese
- Ortopedia e Traumatologia, Ospedale Civile, 10015 Ivrea, Italy
| | - Giancarlo Bonzanini
- Ortopedia e Traumatologia, Ospedale Sant'Antonio e Margherita, 15057 Tortona, Italy
| | - Lorenzo Banci
- Clinical Research Department, Permedica Orthopaedics, 23807 Merate, Italy
| | - Lucio Piovani
- Ortopedia e Traumatologia, Ospedale Santa Croce e Carle, 12100 Cuneo, Italy
| |
Collapse
|
6
|
Waseem S, Fong DTP, Onsa M, Khan W, Singh S. Dual Mobility Total Hip Replacements in Young Patients- A Systematic Review. Indian J Orthop 2023; 57:203-210. [PMID: 36777127 PMCID: PMC9880113 DOI: 10.1007/s43465-022-00787-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Accepted: 11/27/2022] [Indexed: 01/04/2023]
Abstract
Background There is little consensus on outcomes of dual Mobility total hip replacement (DM-THR) in younger patients. We performed a systematic review to examine this. Methods A systematic review of all observational studies and randomised controlled trials of patients under 70 with primary DM-THR in MEDLINE, EMBASE, Pubmed, Cochrane was performed according to PRISMA guidelines. Collected data included demographics, revision, dislocation and infection rates and functional scores. Results Twelve papers studying 738 DM-THR in 664 patients were included. The mean patient age was 46.9 years (13.5-69.0), with 319 (48.0%) being female and 419 (52.0%) being male. After an average follow-up of 90.0 months (1-371 months), the revision rate was 12.7% (84 hips), 0 dislocations were reported but 2.5% (15 hips) underwent intra-prosthetic dislocation. 32.1% hip revisions were due to aseptic loosening. Conclusion Limited literature surrounding the use of DM-THR suggests favourable stability but higher revision rates than conventional THR.
Collapse
Affiliation(s)
- Saima Waseem
- Department of Trauma and Orthopaedics, North West Anglia NHS Foundation Trust, Cambridgeshire, UK
| | - Daniel T. P. Fong
- National Centre for Sport and Exercise Medicine, School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
| | - Mohammed Onsa
- Department of Trauma and Orthopaedics, North West Anglia NHS Foundation Trust, Cambridgeshire, UK
| | - Wasim Khan
- Department of Trauma and Orthopaedics, Addenbrooke’s Hospital, Cambridge, UK
| | - Sarvpreet Singh
- Department of Trauma and Orthopaedics, North West Anglia NHS Foundation Trust, Cambridgeshire, UK
| |
Collapse
|
7
|
Bellova P, Goronzy J, Riedel R, Grothe T, Hartmann A, Günther KP. Dual-Mobility Cups in Primary Total Hip Arthroplasty. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE 2023; 161:74-84. [PMID: 34500491 DOI: 10.1055/a-1527-7758] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Dual-mobility cups (DMCs) were introduced in France more than 40 years ago and are increasingly used not only in hip revision but also primary hip arthroplasty. Due to a simulated large-head articulation and increased jumping distance, DMCs can contribute to a high range of motion in the hip joint and reduce the risk of instability. Numerous studies have reported low dislocation rates and high survival rates in the mid-term follow-up. Nevertheless, long-term data, especially on primary hip replacement, remain limited, and the effect of recent designs and material innovations is still unclear. Therefore, primary DMCs are mainly proposed in patients at high risk for dislocation (i.e. pelvitrochanteric insufficiency, compromised spinopelvic mobility, neuromuscular disorders, obesity and femoral neck fractures). Based on a review of recently published studies referring to these indications, the current study discusses the advantages and disadvantages of DMCs.
Collapse
Affiliation(s)
- Petri Bellova
- Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Dresden, Germany
| | - Jens Goronzy
- Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Dresden, Germany
| | - Roman Riedel
- Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Dresden, Germany
| | - Tim Grothe
- Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Dresden, Germany
| | - Albrecht Hartmann
- Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Dresden, Germany
| | - Klaus-Peter Günther
- Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Dresden, Germany
| |
Collapse
|
8
|
Letissier H, Barbier A, Tristan L, Dubrana F, Lefèvre C, Clavé A. Long-term survival of the Lefèvre retentive cup: 12-year follow-up analysis of 466 consecutive cases. Orthop Traumatol Surg Res 2022; 108:103173. [PMID: 34896581 DOI: 10.1016/j.otsr.2021.103173] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 02/26/2021] [Accepted: 03/02/2021] [Indexed: 02/03/2023]
Abstract
INTRODUCTION The Lefèvre retentive cup is a salvage solution for total hip replacement at high risk of dislocation. Only a few studies have reported the medium or long-term survival; most often, only a small number of patients were included in these studies. This led us to conduct a retrospective analysis of a large population to determine: 1) the 10-year survival rate after primary or revision arthroplasty, 2) the complication rate. HYPOTHESIS The dislocation rate is<5% for revision arthroplasty and<2% for primary arthroplasty. MATERIAL AND METHODS This single-center retrospective study included 466 consecutive total hip replacements performed with the Lefèvre retentive cup with a 12-year theoretical minimum follow-up (1/1/1998 to 31/8/2006). There were 257 indications for primary arthroplasty and 209 for revision arthroplasty. The cohort had 316 women and the mean age at surgery was 72.9years (30.2-89.9). The mean follow-up was 10.2±5 years (0.1-19.3). A statistical analysis was done based on the Kaplan-Meier survival curves in two subsets of patients: primary and revision surgery. RESULTS At the final review, 264 patients had died because of reasons unrelated to the procedures (mean 7.8±4.7years after the procedure), 48 were lost to follow-up (mean 3.0±3.3years after the procedure), and 39 patients (8%) had undergone acetabular revision of which 12 were for infection (2.5%), 25 were for loosening (5.4%) (5 femoral loosening only) and 2 were for dislocation (0.4%). In all, there were 10/466 dislocations (2.1%) of which 5/257 (1.9%) were in the primary group and 5/209 (2.4%) were in the revision group: 2 had a cup exchange and 8 were reduced by closed procedures. The probability of survival free of mechanical complications at 10years was estimated at 94.8%±1.6% (95% CI: 91.6%-98.0%) for the primary group and 87.8%±2.7% (95% CI: 82.4%-93.2%) for the revision groups (p=0.0017). There were 39 re-operations in the overall cohort: 1/257 (0.4%) for dislocation, 7/257 (2.7%) for aseptic loosening and 3/257 (1.2%) for infection in the primary group, while in the revision group, 1/209 (0.5%) was for dislocation, 18/209 (8.6%) for aseptic loosening and 9/209 (4.3%) for infection. CONCLUSION The Lefèvre retentive cup has good long-term survival with a low mechanical complication rate, both in primary and revision surgery. To us, this implant appears to be a reliable salvage procedure for total hip replacement in patients at high risk for dislocation. LEVEL OF EVIDENCE IV; retrospective study without control group.
Collapse
Affiliation(s)
- Hoel Letissier
- Service de chirurgie orthopédique et traumatologique, CHRU de la cavale blanche, 29200 Brest, France; Laboratoire de traitement de l'information médicale (LaTIM, UMR1101), bâtiment IBRBS, 22, avenue Camille-Desmoulins, 29200 Brest, France.
| | - Aurélien Barbier
- Service de chirurgie orthopédique et traumatologique, CHRU de la cavale blanche, 29200 Brest, France
| | - Ludovic Tristan
- Service de chirurgie irthopédique, clinique du Ter, 5, allée de la clinique du Ter, 56270 Ploemeur, France
| | - Frédéric Dubrana
- Service de chirurgie orthopédique et traumatologique, CHRU de la cavale blanche, 29200 Brest, France
| | - Christian Lefèvre
- Service de chirurgie orthopédique et traumatologique, CHRU de la cavale blanche, 29200 Brest, France; Laboratoire de traitement de l'information médicale (LaTIM, UMR1101), bâtiment IBRBS, 22, avenue Camille-Desmoulins, 29200 Brest, France
| | - Arnaud Clavé
- Laboratoire de traitement de l'information médicale (LaTIM, UMR1101), bâtiment IBRBS, 22, avenue Camille-Desmoulins, 29200 Brest, France; Service de chirurgie orthopédique, polyclinique Saint-George, 2, avenue de Rimiez, 06105 Nice, France
| |
Collapse
|
9
|
Rodríguez Pérez D, Agulló Ferre JL, Del Carmen Rodríguez M, Tramunt Monsonet C. Late Breakage of a Dual-Mobility Polyethylene Insert in a Revision Total Hip Arthroplasty: An Unusual Failure Mode. Arthroplast Today 2021; 12:7-11. [PMID: 34746346 PMCID: PMC8551416 DOI: 10.1016/j.artd.2021.07.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Revised: 07/21/2021] [Accepted: 07/26/2021] [Indexed: 11/09/2022] Open
Abstract
The use of dual-mobility cups has gained popularity in recent years. Thus, surgeons can expect an increase in known and new causes of failure. We report a previously undescribed form of a late intraprosthetic dislocation consisting of a complete breakage of a polyethylene mobile bearing that suffered a dislocation 3 months after its implantation. Two years later, he began feeling anterior groin pain and suffered gait changes. Computed tomography scan revealed an eccentric alignment of the mobile polyethylene bearing suggestive of poly wear. During the revision surgery, the polyethylene was found to be split in 2. Possible causes of this complication are proposed. Our case shows a previously unreported implant-specific complication, so surgeons can identify it.
Collapse
|
10
|
Lygrisse KA, Matzko C, Shah RP, Macaulay W, Cooper JH, Schwarzkopf R, Hepinstall MS. Femoral Neck Notching in Dual Mobility Implants: Is This a Reason for Concern? J Arthroplasty 2021; 36:2843-2849. [PMID: 33875287 DOI: 10.1016/j.arth.2021.03.043] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 03/08/2021] [Accepted: 03/16/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Dual mobility (DM) total hip arthroplasty (THA) implants have been advocated for patients at risk for impingement due to abnormal spinopelvic mobility. Impingement against cobalt-chromium acetabular bearings, however, can result in notching of titanium femoral stems. This study investigated the incidence of femoral stem notching associated with DM implants and sought to identify risk factors. METHODS A multicenter retrospective study reviewed 256 modular and 32 monoblock DM components with minimum 1-year clinical and radiographic follow-up, including 112 revisions, 4 conversion THAs, and 172 primary THAs. Radiographs were inspected for evidence of femoral notching and to calculate acetabular inclination and anteversion. Revisions and dislocations were recorded. RESULTS Ten cases of femoral notching were discovered (3.5%), all associated with modular cylindrospheric cobalt-chromium DM implants (P = .049). Notches were first observed radiographically at mean 1.3 years after surgery (range 0.5-2.7 years). Notch location was anterior (20%), superior (60%), or posterior (20%) on the prosthetic femoral neck. Notch depth ranged from 1.7% to 20% of the prosthetic neck diameter. Eight cases with notching had lumbar pathology that can affect spinopelvic mobility. None of these notches resulted in stem fracture, at mean 2.7-year follow-up (range 1-7.6 years). There were no dislocations or revisions in patients with notching. CONCLUSION Femoral notching was identified in 3.5% of DM cases, slightly surpassing the dislocation rate in a cohort selected for risk of impingement and instability. Although these cases of notching have not resulted in catastrophic failures thus far, further study of clinical sequelae is warranted. Component position, spinopelvic mobility, and implant design may influence risk.
Collapse
Affiliation(s)
| | - Chelsea Matzko
- Department of Orthopedic Surgery, Lenox Hill Hospital, New York, NY
| | - Roshan P Shah
- Department of Orthopedic Surgery, Columbia Univeristy Irving Medical Center, New York, NY
| | - William Macaulay
- Department of Orthopedic Surgery, NYU Langone Health, New York, NY
| | - John H Cooper
- Department of Orthopedic Surgery, Columbia Univeristy Irving Medical Center, New York, NY
| | - Ran Schwarzkopf
- Department of Orthopedic Surgery, NYU Langone Health, New York, NY
| | - Matthew S Hepinstall
- Department of Orthopedic Surgery, NYU Langone Health, New York, NY; Department of Orthopedic Surgery, Lenox Hill Hospital, New York, NY
| |
Collapse
|
11
|
Lee GC, Kamath A, Courtney PM. Clinical Concerns With Dual Mobility- Should I Avoid it When Possible? J Arthroplasty 2021; 36:S88-S91. [PMID: 33549418 DOI: 10.1016/j.arth.2021.01.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Accepted: 01/05/2021] [Indexed: 02/02/2023] Open
Abstract
The utilization of dual mobility (DM) articulations in total hip arthroplasty (THA) is increasing. The principal appeal of DM implants is its ability to reduce postoperative instability by maximizing the effective ball head size for each reconstruction. However, while DM implants have been used worldwide for over 3 decades, the experience in North America is more limited. Moreover, there remains concerns with intraprosthetic dissociation, wear, metallosis, and soft tissue impingement. Therefore, the purpose of this article is to review the available evidence for these potential issues. First, intraprosthetic dissociation (IPD) is a unique complication of DM implants. Although the rate has decreased with improvements in materials and design, the reported prevalence is approximately 1%. Second, wear in DM implants can be unpredictable and increased wear has been reported in younger, active patients. Third, corrosion in modular DM implants has been described and elevations in serum cobalt and chromium levels have been reported. While the clinical significance of these elevations is unclear, it remains a source of concern with these implants. Finally, psoas impingement and entrapment can be a source of persistent groin pain after THA. DM articulations are a valuable addition to the armamentarium of total hip surgeons. However, these bearings are not free of complications. Consequently, current data only support selective use of DM bearings in patients at increased risk for postoperative instability after arthroplasty.
Collapse
Affiliation(s)
- Gwo-Chin Lee
- Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA
| | - Atul Kamath
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - P Maxwell Courtney
- Department of Orthopaedic Surgery, Rothman Orthopaedic Institute, Philadelphia, PA
| |
Collapse
|
12
|
Acuña AJ, Courtney PM, Kurtz SM, Lee GC, Kamath AF. Spine Fusions, Yoga Instructors, and Hip Fractures: The Role of Dual Mobility in Primary Total Hip Arthroplasty. J Arthroplasty 2021; 36:S70-S79. [PMID: 33516631 DOI: 10.1016/j.arth.2020.12.057] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/24/2020] [Accepted: 12/30/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Despite the increased use of dual mobility (DM) in primary total hip arthroplasty (THA), debate exists regarding the indications for its use. No specific algorithm exists to guide this decision-making process. Therefore, the purpose of this article is to summarize the currently available literature regarding the use of DM in primary THA and provide evidence-based guidelines based on specific patient populations and risk factors for instability. METHODS We reviewed the current literature for studies evaluating risk factors for dislocation in primary THA, as well as the clinical use and results of DM in primary THA. Based on the strength of the literature, we discuss the use of DM in specific patient populations. We provide a decision-making algorithm to determine whether a patient may be indicated for DM in primary THA. RESULTS Surgeons should consider preoperative patient demographics, risk factors for instability (eg, significant hip-spine issues), type of procedure to be performed (eg, conversion arthroplasty), and indications for surgery (eg, THA for femoral neck fracture). Based on this algorithmic assessment, DM may be warranted in the primary THA setting if a patient's combined risk reaches an established threshold based on the literature. CONCLUSION This evidence-based algorithm may help guide current practice in the use of DM in primary THA. We advocate the continued judicious use of DM in hip arthroplasty. Longer term studies are needed in order to evaluate the durability of DM, as well as any complications related to the DM articulation.
Collapse
Affiliation(s)
- Alexander J Acuña
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, Ohio
| | - P Maxwell Courtney
- Department of Orthopaedic Surgery, Rothman Institute, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania
| | - Steven M Kurtz
- Implant Research Center, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania; Biomedical Engineering Practice, Exponent Inc, Menlo Park, California
| | - Gwo-Chin Lee
- Department of Orthopaedic Surgery, University of Pennsylvania, Penn Musculoskeletal Center, Philadelphia, Pennsylvania
| | - Atul F Kamath
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, Ohio
| |
Collapse
|
13
|
Unter Ecker N, Kocaoğlu H, Zahar A, Haasper C, Gehrke T, Citak M. What Is the Dislocation and Revision Rate of Dual-mobility Cups Used in Complex Revision THAs? Clin Orthop Relat Res 2021; 479:280-285. [PMID: 32898046 PMCID: PMC7899605 DOI: 10.1097/corr.0000000000001467] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Accepted: 08/03/2020] [Indexed: 01/31/2023]
Abstract
BACKGROUND Dual-mobility cups have been shown to reduce the dislocation risk after THA. Although dual-mobility cups can be a useful strategy to mitigate against recurrent dislocation after revision surgery, few clinical studies have focused on the results of complex revision THAs with extensive bone and soft-tissue loss or in patients who have undergone more than one previous surgical procedure. QUESTIONS/PURPOSES (1) What is the survival free from revision for dislocation of dual-mobility cups used in complex revision THAs? (2) What is the survival free from any dislocation? METHODS Between January 1, 2009 and December 31, 2013, 327 patients underwent a complex revision THA that included an acetabular revision, defined as preexisting massive bone loss in the acetabulum (at least Paprosky Type 2B) and/or proximal femur (at least Paprosky Type 3), substantial gluteal soft-tissue involvement, at least two previous surgical procedures or a one-stage septic revision, or history of dislocation. All 327 complex revision patients received a dual-mobility cup. Of those, 34% (111) were lost to follow-up before 5 years and were not known to have reached a study endpoint (revision for dislocation, and any dislocation) before then, leaving 216 patients for analysis. For patients with bilateral hip surgeries only the first operated hip was included for analysis. The median (range) follow-up duration was 69 months (60 to 110). The primary endpoint was dislocation or re-revision for dislocation. Fifty-six percent (120 of 216) of the patients were women and 44% (96 of 216) were men. The mean age of the patients was 69 ± 9 years. The patients underwent a median of four surgical procedures (1 to 4) before the index procedure (the revision evaluated in this study). A survival analysis was performed using the Kaplan-Meier method; any dislocation or revision for dislocation was determined as the endpoint. RESULTS The dislocation-free survival rates were 96% (95% confidence interval 92 to 98) at 5 years and 82% (95% CI 72 to 89) at 9 years. The overall dislocation rate was 11% (24 of 216 patients) at the final follow-up interval. Survival free of revision for dislocation was 99% (95% CI 96 to 100) at 5 years and 85% (95% CI 75 to 92) at 9 years. CONCLUSIONS Dual-mobility cups used in complex revision THA in this series had a higher rate of dislocation and revision than expected, based on earlier studies of dislocations of these components. Although we believe dual-mobility cups are still the first choice of implant if the patient has instability, these cups should be used cautiously if severe bone loss or soft-tissue involvement is present. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
Affiliation(s)
- Niklas Unter Ecker
- N. U. Ecker, H. Kocaoğlu, C. Haasper, T. Gehrke, M. Citak, Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- H. Kocaoğlu, Department of Orthopedics and Traumatology, Ankara University Faculty of Medicine, Ankara, Turkey
- A. Zahar, Department of Orthopaedic Surgery, Helios Klinik Berlin- Zehlendorf, Berlin, Germany
| | - Hakan Kocaoğlu
- N. U. Ecker, H. Kocaoğlu, C. Haasper, T. Gehrke, M. Citak, Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- H. Kocaoğlu, Department of Orthopedics and Traumatology, Ankara University Faculty of Medicine, Ankara, Turkey
- A. Zahar, Department of Orthopaedic Surgery, Helios Klinik Berlin- Zehlendorf, Berlin, Germany
| | - Akos Zahar
- N. U. Ecker, H. Kocaoğlu, C. Haasper, T. Gehrke, M. Citak, Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- H. Kocaoğlu, Department of Orthopedics and Traumatology, Ankara University Faculty of Medicine, Ankara, Turkey
- A. Zahar, Department of Orthopaedic Surgery, Helios Klinik Berlin- Zehlendorf, Berlin, Germany
| | - Carl Haasper
- N. U. Ecker, H. Kocaoğlu, C. Haasper, T. Gehrke, M. Citak, Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- H. Kocaoğlu, Department of Orthopedics and Traumatology, Ankara University Faculty of Medicine, Ankara, Turkey
- A. Zahar, Department of Orthopaedic Surgery, Helios Klinik Berlin- Zehlendorf, Berlin, Germany
| | - Thorsten Gehrke
- N. U. Ecker, H. Kocaoğlu, C. Haasper, T. Gehrke, M. Citak, Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- H. Kocaoğlu, Department of Orthopedics and Traumatology, Ankara University Faculty of Medicine, Ankara, Turkey
- A. Zahar, Department of Orthopaedic Surgery, Helios Klinik Berlin- Zehlendorf, Berlin, Germany
| | - Mustafa Citak
- N. U. Ecker, H. Kocaoğlu, C. Haasper, T. Gehrke, M. Citak, Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- H. Kocaoğlu, Department of Orthopedics and Traumatology, Ankara University Faculty of Medicine, Ankara, Turkey
- A. Zahar, Department of Orthopaedic Surgery, Helios Klinik Berlin- Zehlendorf, Berlin, Germany
| |
Collapse
|
14
|
Kolz JM, Wyles CC, Van Citters DW, Chapman RM, Trousdale RT, Berry DJ. In Vivo Corrosion of Modular Dual-Mobility Implants: A Retrieval Study. J Arthroplasty 2020; 35:3326-3329. [PMID: 32600814 DOI: 10.1016/j.arth.2020.05.075] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 05/26/2020] [Accepted: 05/29/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Modular dual-mobility (MDM) total hip arthroplasty (THA) implants have an additional metal-metal interface between the metal liner and outer metal shell that poses a risk of corrosion. The purpose of this study is to evaluate retrieved MDM liners to evaluate qualitative and quantitative damage and corrosion patterns at this interface. METHODS Twelve MDM implants of one design with a mean in situ duration of 26 months (range, 1-57 months) were evaluated. Six implants (50%) were from primary THAs and 6 (50%) from revision THAs. The taper region of the liner at risk of damage was qualitatively graded using modified Goldberg criteria while quantitative dimensional assessment was performed with a validated coordinate measurement machine. RESULTS Among the retrieved implants, 2 (17%) demonstrated severe grade 4 corrosion, 5 (42%) moderate grade 3 corrosion, 4 (33%) mild grade 2 corrosion, and 1 (8%) grade 1 (no visible corrosion). Mean maximum linear corrosion depth at the taper interface measured 35.5 microns (range, 8.4-176.2 microns). All implants had a maximum linear corrosion depth >7 microns, a threshold suggestive of potentially clinically significant material loss. Three corrosion patterns were identified: generalized corrosion, a stripe of corrosion about the middle of the taper region, and focal areas of corrosion at the portion of the taper closest to the joint surface. CONCLUSION Visual and dimensional analysis of all 12 retrieved MDM implants demonstrated identifiable corrosion/wear of the cobalt-chromium metal liner taper of varying severity. These implants should be used judiciously until larger series with clinical correlation can be completed.
Collapse
Affiliation(s)
- Joshua M Kolz
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN
| | - Cody C Wyles
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN
| | | | - Ryan M Chapman
- Thayer School of Engineering, Dartmouth College, Hanover NH
| | | | - Daniel J Berry
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN
| |
Collapse
|
15
|
Dual Mobility Bearing Articulations Result in Lower Rates of Dislocation After Revision Total Hip Arthroplasty. J Am Acad Orthop Surg 2020; 28:831-837. [PMID: 31834038 DOI: 10.5435/jaaos-d-19-00532] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
INTRODUCTION The purpose of our study is to directly compare the rates of instability after revision total hip arthroplasty (THA) between a modular dual mobility (DM) and a conventional polyethylene single-bearing surface. METHODS We retrospectively reviewed a consecutive series of patients who underwent revision THA from 2012 to 2016 at a single institution with a minimum of 2 years of follow-up. Rates of re-revision, dislocation, complications, and short-form (SF-12) scores were compared between the DM and single-bearing groups. To control for confounding variables, a multivariate logistic regression analysis was performed. RESULTS Of the 267 revision THA patients, 94 patients had a DM bearing articulation (36%), whereas 173 patients (64%) had a conventional single-bearing with a mean follow-up of 37.8 months (range 24 to 73 months). The DM group was more likely to undergo revision THA for instability compared with the single-bearing group (8.5% versus 1.2%, P ≤ 0.005) but had reduced incidence of postoperative dislocations (2.1% versus 8.7%, P = 0.067) and no difference in the rates of re-revisions (9.6% versus 11.6%, P = 0.770). When controlling for confounding variables, patients who received a DM liner had lower rates of dislocation postoperatively than those of single-bearing (odds ratio 0.12, P = 0.019). DISCUSSION Even with a selection bias of surgeons using DM for patients at high risk of instability, patients undergoing revision THA with a DM bearing have reduced rates of dislocation at the intermediate-term follow-up. Further study is needed to identify any potential longer-term complications which may result from a modular DM bearing.
Collapse
|
16
|
Vajapey SP, Fideler KL, Lynch D, Li M. Use of dual mobility components in total hip arthroplasty: Indications and outcomes. J Clin Orthop Trauma 2020; 11:S760-S765. [PMID: 32999552 PMCID: PMC7503159 DOI: 10.1016/j.jcot.2020.07.035] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 07/26/2020] [Accepted: 07/30/2020] [Indexed: 12/23/2022] Open
Abstract
Instability after total hip arthroplasty (THA) can be a problematic complication and remains one of the leading causes of revision surgery in the early post-operative period. Dual mobility (DM) implants decrease dislocation risk after THA but they come with their own set of complications. Selective use of DM implants for THA in high risk groups can confer the advantages of this construct while mitigating the risks. In this paper, we review the current literature to examine the evidence for or against use of DM implants in various clinical scenarios and provide an algorithm for when to consider using DM design construct in THA.
Collapse
Affiliation(s)
- Sravya P. Vajapey
- Department of Orthopaedics, The Ohio State University Wexner Medical Center, United States
| | - Kathryn L. Fideler
- Department of Orthopaedics, The Ohio State University Wexner Medical Center, United States
| | - Daniel Lynch
- School of Medicine, The Ohio State University Wexner Medical Center, United States
| | - Mengnai Li
- Department of Orthopaedics, The Ohio State University Wexner Medical Center, United States,Corresponding author. Adult Reconstructive Surgery, Department of Orthopaedics, Ohio State University Wexner Medical Center, 725 Prior Hall Columbus, Ohio, 43210, United States.
| |
Collapse
|
17
|
Onochi Y, Fukui K, Kaneuji A, Ichiseki T, Wang X, Kawahara N. Dual mobility acetabular construct with freedom constrained liner for treatment of recurrent dislocations after total hip arthroplasty: A case report and literature review. Int J Surg Case Rep 2020; 75:94-99. [PMID: 32932039 PMCID: PMC7493044 DOI: 10.1016/j.ijscr.2020.09.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 09/03/2020] [Accepted: 09/03/2020] [Indexed: 11/18/2022] Open
Abstract
Dual-mobility bearings improve stability in total hip arthroplasty (THA) but may fail to prevent postoperative dislocation. Dry revision with a compatible constrained liner system can provide an effective salvage option for instability after THA. The unique G7 constrained liner system offers good short-term stability and range of motion.
Introduction Recurrent dislocation after total hip arthroplasty (THA) using the dual mobility cup system can present challenges, while dual-mobility THA bearings can improve stability in both primary and revision total hip arthroplasties. Presentation of case A 72-year-old woman with a history of schizophrenia underwent a left primary THA using the G7 dual mobility system. Two postoperative posterior dislocations occurred within 2 months post-surgery. The patient underwent revision surgery in which the metal liner and dual mobility head were exchanged using the Freedom constrained liner system without revision of the cup and stem. As of this writing, 28 months after the revision surgery, no further dislocations have occurred. The implants are stable, and the patient has good range of motion. Discussion Dual-mobility bearings are utilized to improve stability in both primary and revision total hip arthroplasties, but even if the dual mobility system is chosen, it sometimes fails to prevent postoperative dislocation. Although a relatively high failure rate has been reported in THA using the constrained liner system, this patient’s clinical course suggests that the G7 Freedom constrained liner system can be an efficacious option for some patients with unstable hip joints who undergo THA using the dual mobility system. Conclusion A modern constrained liner system such as the G7 Freedom liner may provide an improved salvage solution for joint instability in dual mobility THA.
Collapse
Affiliation(s)
- Yuuki Onochi
- Department of Orthopedic Surgery, Kanazawa Medical University, Japan
| | - Kiyokazu Fukui
- Department of Orthopedic Surgery, Kanazawa Medical University, Japan.
| | - Ayumi Kaneuji
- Department of Orthopedic Surgery, Kanazawa Medical University, Japan
| | - Toru Ichiseki
- Department of Orthopedic Surgery, Kanazawa Medical University, Japan
| | - Xipeng Wang
- Department of Orthopedic Surgery, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Norio Kawahara
- Department of Orthopedic Surgery, Kanazawa Medical University, Japan
| |
Collapse
|
18
|
Agarwala S, Shetty V, Taywade S, Vijayvargiya M, Bhingraj M. Dual mobility THR: Resolving instability and providing near normal range of movement. J Clin Orthop Trauma 2020; 13:40-45. [PMID: 33680805 PMCID: PMC7919931 DOI: 10.1016/j.jcot.2020.08.023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 08/17/2020] [Accepted: 08/26/2020] [Indexed: 01/17/2023] Open
Abstract
BACKGROUND Dislocation is a common complication of Total Hip Replacement (THR), particularly when performed in primary (indications with increased risk of instability) and in revision scenarios. Dual mobility THR (DMTHR) minimizes the risk of instability in such scenarios, however most of the evidence is from western literature. Results of DMTHR in Indian scenarios where patient want to go back to their normal routine activities of squatting and sitting cross-legged is lacking. The aim of our study was to evaluate the short to mid-term results of DMTHR for varied indications (both primary and revision) in Indian scenario. To evaluate the outcome of the DMTHR in terms of functional range of motion and the ability to go back to their pre-injury level of activity. METHODS This is a retrospective study of 150 patients operated with DMTHR between January 2015 to February 2019 with a minimum follow-up of 12 months. Patients were evaluated clinically using Modified Harris Hip Score (HHS), Range of Motion (ROM), and Patient Reported Outcome Measures (PROM) like ability to squat and sit cross legged. Radiological evaluation was done using radiographs to assess loosening, stress shielding, osteolysis. RESULTS Mean follow up in our study was 25.2 months (Range 12-46 months). Mean Modified HHS was 71.8 ± 8.11 at 6 weeks post-op and 85.8 ± 7.62 at last follow-up. HHS showed excellent outcome in 36 hips (26.7%), good outcome in 76 hips (56.7%), fair outcome in 20 hips (14.6%), poor outcome in 3 hips (2%). All our patients were allowed to squat and sit cross-legged at a mean follow-up period of 13 weeks (8 weeks-20 weeks) except 10 cases of Revision THR where patients were advised not to squat or sit cross-legged. All patients were able to resume their activities of daily living. CONCLUSION DMTHR in patients of all ages has shown a good short to midterm clinical outcome which is comparable to conventional THR. It confers the benefit of stability allowing our patients to squat and sit cross legged which is often one of the expectation and requirement of a patient undergoing THR in India. DMTHR in both primary and revision scenarios exhibit a low risk of dislocation, complications and revision surgery.
Collapse
Affiliation(s)
- Sanjay Agarwala
- Corresponding author. Consultant Orthopedic Surgeon, Director-Professional Services, P.D. Hinduja National Hospital, Veer Savarkar Marg, Mahim (W), Mumbai-16, Mumbai, India.
| | | | | | | | | |
Collapse
|
19
|
Yoon JY, Moon JK, Kim CH, Lee S, Yoon PW. Korean epidemiology and trends in hip joint replacements. JOURNAL OF THE KOREAN MEDICAL ASSOCIATION 2020. [DOI: 10.5124/jkma.2020.63.8.462] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
This study aimed to analyze the epidemiologic characteristics of patients who underwent hip arthroplasty using the Korean nationwide database and investigate the recent trends in implant fixation methods and bearing surface selection. We aimed to compare clinical characteristics and differences with the results from the registry of other western countries. We analyzed the data collected by the Health Insurance Review and Assessment Service database of Korea from 2007 to 2011 and the Main Surgery Statistical Yearbook from 2014 to 2018, published by the National Health Insurance Service. The number and rate of patients who underwent hip joint arthroplasty per 10,000 persons have been steadily increasing since 2007. There was a big difference in mean age and preoperative diagnosis of patients between the bipolar hemiarthroplasty and total hip arthroplasty groups. Most patients underwent surgery using a cementless biological fixation method, and the cemented fixation method was selectively used for a small portion of old aged osteoporotic patients. In relation to the use of bearing surfaces, the registry data showed that ceramic-ceramic bearings were used at an overwhelmingly high rate (81%) in Korea compared to other countries. The reason was attributable to various factors, such as patient’s age or economic status, differences in the health insurance system between countries, and recently reported complications, such as ceramic fracture or noise.
Collapse
|
20
|
Young JR, O’Connor CM, Anoushiravani AA, DiCaprio MR. The Use of Dual Mobility Implants in Patients Who Are at High Risk for Dislocation After Primary Total Hip Arthroplasty. JBJS Rev 2020; 8:e20.00028. [DOI: 10.2106/jbjs.rvw.20.00028] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
21
|
Novel Constrained Dual Mobility Hip Prosthesis to Combat Instability in Revision Total Hip Arthroplasty whilst Preserving Normal Function. Case Rep Orthop 2020; 2020:6390310. [PMID: 32724692 PMCID: PMC7364194 DOI: 10.1155/2020/6390310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Revised: 06/26/2020] [Accepted: 06/30/2020] [Indexed: 12/04/2022] Open
Abstract
We present the case of a male patient with sepsis and a chronic discharging sinus in a multirevised total hip replacement. Following extensive debridement, the reimplanted hip became unstable. With the patient's long-term desire to return to work and ride a bicycle with his children, the patient agreed to proceed with a novel, custom-designed, constrained dual mobility liner which allowed unrestricted movement. In 2017, the patient underwent revision surgery with this novel dual mobility constrained prosthesis. The patient was very quickly able to regain independence. After 16 years of unemployment, he managed to return to gainful employment as a cleaner rapidly regaining function as well as finally being able to ride a bike with his children for the first time.
Collapse
|
22
|
Chouteau J, Rollier JC, Bonnin MP, Saffarini M, Nover L, Chatelet JC, Jacquot L. Absence of instabilities and intra-prosthetic dislocations at 7 to 11 years following THA using a fourth-generation cementless dual mobility acetabular cup. J Exp Orthop 2020; 7:51. [PMID: 32661747 PMCID: PMC7359208 DOI: 10.1186/s40634-020-00265-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Accepted: 06/16/2020] [Indexed: 12/23/2022] Open
Abstract
PURPOSE Dual-mobility (DM) cups are increasingly used in total hip arthroplasty (THA) but there lacks literature on their long-term results. We aimed to investigate outcomes of a fourth-generation cementless DM acetabular cup at 7-11 years. METHODS We retrospectively evaluated 240 consecutive hips that received cementless THA using the same dual mobility cup (Novae Sunfit TH) and femoral stem (Corail). Patients were recalled at ≥7 years to collect Oxford hip scores (OHS), Harris hip scores (HHS), and inspect for radiolucent lines and granulomas. Multi-variable analyses were performed to determine whether HHS or OHS were associated with pre- or intra-operative variables. RESULTS At 8.4 ± 0.8 years (range, 7-11), 6 hips were revised (2.5%), 54 deceased (22.5%), and 14 could not be reached (5.8%). Four revisions (2 cup+stem, 2 liners only) were due to sepsis (1.7%), one (cup and stem) for trauma (0.4%), and one (stem) due to aseptic loosening (0.4%). For the remaining 166 hips, HHS was 83.6 ± 13.2 and OHS was 20.3 ± 6.7. Multi-variable analysis confirmed that HHS (β = - 0.38; p = 0.039) and OHS (β = 0.36; p < 0.001) worsened with age, and that OHS was worse for Charnley C patients (β = 3.17; p = 0.009). Neither granulomas nor radiolucenies were observed around any cups, but radiolucenies were seen around 25 stems (20.3%). CONCLUSIONS This fourth-generation DM cup demonstrated satisfactory outcomes at 7-11 years, with no instabilities or cup revisions due to aseptic loosening. Better OHS was observed for younger patients and those presenting higher Charnley grade. LEVEL OF EVIDENCE Level IV, retrospective case study.
Collapse
Affiliation(s)
- Julien Chouteau
- Artro Group Institute, Lyon, France.,Clinique d'Argonay, Ramsay Santé, Annecy, France
| | - Jean-Charles Rollier
- Artro Group Institute, Lyon, France.,Clinique d'Argonay, Ramsay Santé, Annecy, France
| | - Michel P Bonnin
- Artro Group Institute, Lyon, France.,Centre Orthopédique Santy, Hôpital Privé Jean Mermoz, Ramsay Santé, Lyon, France
| | | | | | - Jean-Christophe Chatelet
- Artro Group Institute, Lyon, France.,Centre de Chirurgie Orthopédique du Beaujolais, Ramsay Santé, Arnas, France
| | - Laurent Jacquot
- Artro Group Institute, Lyon, France.,Clinique d'Argonay, Ramsay Santé, Annecy, France
| |
Collapse
|
23
|
Neri T, Boyer B, Batailler C, Klasan A, Lustig S, Philippot R, Farizon F. Dual mobility cups for total hip arthroplasty: tips and tricks. SICOT J 2020; 6:17. [PMID: 32553100 PMCID: PMC7301635 DOI: 10.1051/sicotj/2020018] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2020] [Accepted: 05/27/2020] [Indexed: 12/12/2022] Open
Abstract
Since its creation in 1974, the Dual Mobility Cup (DMC) has been gaining in popularity, especially in the past decade. This intensive use could lead to inappropriate use and consequently to an increased complication rate. Compliance with conceptual requirements and surgical techniques will prevent the occurrence of complications that can be wrongly attributed to implants. In this context, we feel that it is essential to share our tips and tricks as well as an overview and an explanation of common errors, based on more than 45 years of clinical and research experience. From basic principles, including indications, implant choice and implant compatibility, to surgical tips, in this article orthopedic surgeons will find a practical overview of DMC in order to use it safely and with confidence.
Collapse
Affiliation(s)
- Thomas Neri
- Department of Orthopaedic Surgery, University Hospital Centre of Saint-Étienne, avenue Albert Raimond, 42000 Saint-Étienne, France - EA 7424 - Inter-University Laboratory of Human Movement Science, University Lyon - University Jean Monnet Saint-Étienne, avenue Albert Raimond, 42000 Saint-Étienne, France
| | - Bertrand Boyer
- Department of Orthopaedic Surgery, University Hospital Centre of Saint-Étienne, avenue Albert Raimond, 42000 Saint-Étienne, France - INSERM U1059 SAINBIOSE, avenue Albert Raimond, 42000 Saint-Étienne, France
| | - Cécile Batailler
- Orthopedic Surgery Department, Croix-Rousse Hospital, 103 Grande Rue de la Croix-Rousse, 69004 Lyon, France
| | - Antonio Klasan
- North Shore Hospital, 124 Shakespeare Road, Takapuna, 0620 Auckland, New Zealand
| | - Sebastien Lustig
- Orthopedic Surgery Department, Croix-Rousse Hospital, 103 Grande Rue de la Croix-Rousse, 69004 Lyon, France
| | - Remi Philippot
- Department of Orthopaedic Surgery, University Hospital Centre of Saint-Étienne, avenue Albert Raimond, 42000 Saint-Étienne, France - EA 7424 - Inter-University Laboratory of Human Movement Science, University Lyon - University Jean Monnet Saint-Étienne, avenue Albert Raimond, 42000 Saint-Étienne, France
| | - Frederic Farizon
- Department of Orthopaedic Surgery, University Hospital Centre of Saint-Étienne, avenue Albert Raimond, 42000 Saint-Étienne, France - INSERM U1059 SAINBIOSE, avenue Albert Raimond, 42000 Saint-Étienne, France
| |
Collapse
|
24
|
Is Isolated Mobile Component Exchange an Option in the Management of Intraprosthetic Dislocation of a Dual Mobility Cup? Clin Orthop Relat Res 2020; 478:279-287. [PMID: 31794492 PMCID: PMC7438138 DOI: 10.1097/corr.0000000000001055] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Intraprosthetic dislocation is a specific complication of dual mobility cups, although it occurs less frequently with the latest generations of implants. Intraprosthetic dislocation is related to long-term polyethylene wear of the mobile component chamfer and retentive area, leading to a snap-out of the femoral head. With the increased use of dual mobility cups, even in younger and active patients, the management of intraprosthetic dislocation should be defined according to its type. However, no previous studies, except for case reports, have described the strategy to manage long-term wear-related intraprosthetic dislocation, particularly when a dual mobility cup is not loose. QUESTIONS/PURPOSES This study aimed to (1) determine the prevalence of intraprosthetic dislocation in this patient population and the macroscopic findings at the time of surgical revision and (2) evaluate whether isolated mobile component exchange could be an option to manage intraprosthetic dislocation occurring with a well-fixed dual mobility cup metal shell. METHODS From January 1991 to December 2009, a continuous series of 5274 THAs with dual mobility cups (4546 patients; 2773 women; mean [range] age 58 years [22-87]; bilateral THA = 728) were prospectively enrolled in our institutional total joint registry. A cementless, hemispherical dual mobility cup was systematically implanted, regardless of the patient's age or indication for THA. At the latest follow-up examination, the registry was queried to isolate each occurrence of intraprosthetic dislocation, which was retrospectively analyzed regarding the patient's demographics, indication for THA, radiographs, intraoperative findings (polyethylene wear and lesion patterns on the mobile component, periarticular metallosis, and implant damage because of intraprosthetic impingement of the femoral neck), management of intraprosthetic dislocation (isolated exchange of the mobile component or revision of the dual mobility cup), and outcome. RESULTS At a mean (range) follow-up duration of 14 years (3-26), 3% of intraprosthetic dislocations (169 of 5274) were reported, with a mean (range) time from THA of 18 years (13-22). Intraprosthetic dislocation occurred predominantly in younger men (mean [range] age at THA, 42 years [22-64] versus 61 years [46-87]; p < 0.001, and sex ratio (male to female, 1:32 [96 male and 73 female] versus 0.62 [1677 male and 2700 female]; p < 0.001) in patients with intraprosthetic dislocation and those without, respectively, but was not influenced by the indication for THA (105 patients with intraprosthetic dislocation who underwent THA for primary hip osteoarthritis and 64 with other diagnoses versus 3146 patients without who underwent THA for primary hip osteoarthritis and 1959 for other diagnoses (p = 0.9)). In all patients with intraprosthetic dislocation, a macroscopic analysis of the explanted mobile component revealed circumferential polyethylene wear and damage to the chamfer and retentive area, with subsequent loss of retaining power for the femoral head. Nine percent of intraprosthetic dislocations (16 of 169 patients with intraprosthetic dislocations) were associated with aseptic loosening of the dual mobility cup and were managed with acetabular revision without recurrence at a mean (range) follow-up duration of 7.5 years (5-11). Ninety-one percent of intraprosthetic dislocations (153 of 169) were pure, related to wear of the mobile component chamfer and retentive area without aseptic loosening of the dual mobility cup, and managed with isolated mobile component exchange. Intraprosthetic dislocation recurred in 6% (nine of 153) at a mean (range) follow-up interval of 3 years (2-4.5). Additionally, severe premature polyethylene wear of the mobile component with loosening of the dual mobility cup occurred in 12% of patients (19 of 153) at a mean (range) follow-up duration of 1.5 years (0.5-3). CONCLUSIONS A failure rate of 18% (28 of 153 patients undergoing isolated mobile component exchange) was reported within 5 years after isolated mobile component exchange to manage intraprosthetic dislocation occurring with a well-fixed dual mobility cup metal shell. The two modes of failure were early recurrence of intraprosthetic dislocation or severe premature metallosis-related polyethylene wear of the mobile component with loosening of the dual mobility cup. Acetabular revision with synovectomy should remain the standard procedure to manage intraprosthetic dislocation, particularly if periarticular metallosis is present. The exception is intraprosthetic dislocation occurring in elderly or frail patients, for whom a conventional acetabular revision procedure would be associated with an unjustified surgical or anesthetic risk. LEVEL OF EVIDENCE Level II, prognostic study.
Collapse
|
25
|
Huten D, Fournier Y, Gicquel T, Bertho P, Basselot F, Hamadouche M. Risk factors for dislocation after revision total hip arthroplasty with a dual-mobility cup. Matched case-control study (16 cases vs. 48 controls). Orthop Traumatol Surg Res 2019; 105:1303-1309. [PMID: 31153859 DOI: 10.1016/j.otsr.2019.01.020] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Revised: 01/15/2019] [Accepted: 01/28/2019] [Indexed: 02/02/2023]
Abstract
BACKGROUND Reports of high dislocation rates after revision total hip arthroplasty (THA) have encouraged the widespread use of dual-mobility cups. Dislocation has been less common but not fully abolished with dual-mobility cups, and its causes have remained unidentified. The objectives of this retrospective matched case-control study were: 1) to identify risk factors for dislocation, 2) and to assess dislocation outcomes. HYPOTHESIS The causes of dislocation after revision THA with a dual-mobility cup can be identified. MATERIAL AND METHOD Among 653 consecutive patients identified retrospectively as having undergone revision THA with a dual-mobility cup (Medial Cup, Aston, Saint-Étienne, France) between January 2007 and December 2017, 16 (2.45%) subsequently experienced dislocation, after a mean of 3.6 months (range, 0.9-19 months). For each of these 16 patients, we collected the main patient characteristics (age, sex, body mass index [BMI], ASA score, and reason for the initial arthroplasty procedure), local history (number of previous surgical procedures, reason for revision, femoral and acetabular bony defects classified according to Paprosky, and status of the abductor apparatus), and characteristics of the revision (approach, diameters of the cup and femoral head, cup inclination, femoral offset, lower limb length, and implant anteversion). Controls were patients without dislocation after revision dual-mobility THA. Each of the 16 patients was matched to 3 controls on age (±10 years), sex, year of revision, and whether revision was only acetabular or bipolar. Univariate and multivariate analyses were done to compare the cases and controls, and dislocation outcomes in the cases were evaluated. RESULTS By univariate analyses, factors associated with dislocation were BMI>30 (cases, 37.5%; controls, 10.4%; p=0.02), larger number of previous surgical procedures on the same hip (cases, 2.8; controls, 1.8; p=0.004), larger number of arthroplasties (cases, 2.3; controls, 1.5; p=0.004), history of instability (cases, 31% with chronic dislocation and 13% with recurrent dislocation; controls, 6.25% and 2.1%, respectively; p=0.004), and compromised abductor apparatus (cases, 56.25%; controls, 14.6%; p=0.002). Independent risk factors for dislocation identified by multivariate analysis were instability (odds ratio [OR], 14.5; 95% confidence interval [95%CI], 1.5-149.9) and, most importantly, abductor apparatus compromise (OR, 43.1; 95%CI, 3.18-586.3). Of the 16 cases, 1 was lost to follow-up, 1 had contra-indications to anaesthesia, 1 died after several dislocation episodes, and 1 died 3 months after surgical reduction. In 5 cases, there was a single dislocation episode. Further surgery was performed in 8 cases (surgical reduction, n=1; constrained cup, n=3; trochanteric internal fixation, n=1; exchange of the dual-mobility cup, n=2, including 1 with subsequent dislocation episodes; and femoral component exchange followed by a retentive cup due to further dislocation episodes, n=1). CONCLUSION Risk factors for dislocation consisted of a history of instability and, most importantly, abductor apparatus compromise. A constrained cup should be considererd in patients with impaired abductor apparatus. No further dislocations occurred after reduction of the first episode in 31.25% of cases. Recurrent dislocation should prompt measures to correct impaired abductor apparatus whenever possible, as well as correction of any component malposition. Whether a retentive cup should be implanted routinely remains unclear. LEVEL OF EVIDENCE III, matched case-control study.
Collapse
Affiliation(s)
- Denis Huten
- Service de chirurgie orthopédique et réparatrice de l'appareil moteur du CHU de Rennes, hôpital Pontchaillou, 2, rue Henri-le-Guilloux, 35000 Rennes, France.
| | - Yohann Fournier
- Service de chirurgie orthopédique et réparatrice de l'appareil moteur du CHU de Rennes, hôpital Pontchaillou, 2, rue Henri-le-Guilloux, 35000 Rennes, France
| | - Thomas Gicquel
- Service de chirurgie orthopédique et réparatrice de l'appareil moteur du CHU de Rennes, hôpital Pontchaillou, 2, rue Henri-le-Guilloux, 35000 Rennes, France
| | - Pierre Bertho
- Service de chirurgie orthopédique et réparatrice de l'appareil moteur du CHU de Rennes, hôpital Pontchaillou, 2, rue Henri-le-Guilloux, 35000 Rennes, France
| | - Frédéric Basselot
- Service de chirurgie orthopédique et réparatrice de l'appareil moteur du CHU de Rennes, hôpital Pontchaillou, 2, rue Henri-le-Guilloux, 35000 Rennes, France
| | - Moussa Hamadouche
- Service d'orthopédie de l'hôpital Cochin, AP-HP, 27, rue du Faubourg Saint-Jacques, 75014 Paris, France
| |
Collapse
|
26
|
Koper M, Verdijk R, Bos K. Asymptomatic intraprosthetic dual mobility cup dislocation with increased metal ion levels. Arthroplast Today 2019; 5:38-42. [PMID: 31020019 PMCID: PMC6470350 DOI: 10.1016/j.artd.2018.12.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2018] [Revised: 12/09/2018] [Accepted: 12/13/2018] [Indexed: 01/18/2023] Open
Abstract
With the increased use of dual-mobility cups (DMCs) in total-and revision hip arthroplasties, surgeons can expect an increase of known and new complications. During routine follow-up, we observed an asymptomatic patient with an intraprosthetic-dislocation (IPD) and elevated levels of serum metal ions (1.8 ppb of cobalt and 28.0 ppb of chromium). Revision surgery was inevitable. Perioperative metallosis and severe wear of the metal shell and metal femoral head supported the IPD. Literature showed that the modularity of the DMC can result in increased serum metal ions, create excessive wear, and possibly affect implant survival. Our case and review of the literature may form an argument not to consider DMC for primary cases. Furthermore, we advise yearly clinical and radiological follow-up and, on indication, metal ion testing for DMCs.
Collapse
Affiliation(s)
- Maarten Koper
- Department of Orthopedics, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Rob Verdijk
- Department of Pathology, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Koen Bos
- Department of Orthopedics, Erasmus Medical Center, Rotterdam, the Netherlands
| |
Collapse
|
27
|
Reina N, Pareek A, Krych AJ, Pagnano MW, Berry DJ, Abdel MP. Dual-Mobility Constructs in Primary and Revision Total Hip Arthroplasty: A Systematic Review of Comparative Studies. J Arthroplasty 2019; 34:594-603. [PMID: 30554926 DOI: 10.1016/j.arth.2018.11.020] [Citation(s) in RCA: 83] [Impact Index Per Article: 16.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Revised: 11/05/2018] [Accepted: 11/10/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Utilization of dual-mobility constructs in total hip arthroplasties (THA) has increased in the recent years. Benefits and risks of these implants in terms of reducing dislocations, long-term survivorship, and associated complications are uncertain when compared to non-dual-mobility articulations. METHODS A systematic review of prospective and retrospective studies that compared dual-mobility constructs with controls for primary or revision THAs between 1986 and 2018 was performed. All articles in both English and French were reviewed. RESULTS Five studies with primary THAs and 6 with revision THAs were analyzed. For primary THAs, the overall rate of dislocation was 0.9% in the dual-mobility group compared to 6.8% in the control group (P < .001) at a mean follow-up of 7.6 years. The odds ratios for the control group to the dual-mobility group were 4.06 (P < .001) for dislocation, 1.18 (P = .87) for revision, 2.97 (P = .04) for revision due to dislocation, 1.67 (P = .57) for infection, 0.6 (P = .53) for fracture, and 1.21 (P = .81) for aseptic loosening. Similarly, for revision THAs, the overall dislocation rates were 2.2% compared to 7.1% (P < .001) at a mean follow-up of 4.1 years. The odds ratios for the control group to the dual-mobility group were 3.59 (P < .001) for dislocation, 2.46 (P < .001) for re-revision, 4.88 (P = .007) for re-revision due to dislocation, 1.51 (P = .32) for infection, 1.18 (P = .81) for fracture, and 2.71 (P = .003) for aseptic loosening. CONCLUSION This systematic review of comparative studies supports the efficacy of dual-mobility constructs to minimize dislocation after both primary and revision THAs in addition to excellent mid-term survivorship compared to control constructs. However, further evidence is needed to evaluate the long-term risks and benefits of dual-mobility constructs in the primary and revision THA setting when compared to contemporary conventional implants. LEVEL OF EVIDENCE III, therapeutic.
Collapse
Affiliation(s)
- Nicolas Reina
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN
| | - Ayoosh Pareek
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN
| | - Aaron J Krych
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN
| | - Mark W Pagnano
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN
| | - Daniel J Berry
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN
| | - Matthew P Abdel
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN
| |
Collapse
|
28
|
Sukeik M, Haddad FS. Periprosthetic joint infections after total hip replacement: an algorithmic approach. SICOT J 2019; 5:5. [PMID: 30816089 PMCID: PMC6394232 DOI: 10.1051/sicotj/2019004] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Accepted: 01/28/2019] [Indexed: 12/25/2022] Open
Abstract
An algorithm for managing periprosthetic joint infections (PJIs) after total hip replacement (THR) surgery using a multidisciplinary approach and a clearly defined protocol may improve infection eradication rates. In this article, we present an algorithm for the management of different types of PJIs including the acutely infected cemented and cementless THRs where the components are well-fixed postoperatively and when the infection is secondary to haematogenous spread in previously well-functioning and well-fixed implants. For chronic PJIs where the components are often loose, the standard treatment includes a two-stage revision procedure. However, in a highly selected subset of patients, a single-stage approach has been utilised with high rates of eradicating infections.
Collapse
Affiliation(s)
- Mohamed Sukeik
- Foothills Medical Centre, 1403 29 St NW Calgary, AB T2N 2T9, Canada
| | - Fares Sami Haddad
- University College London Hospital, 235 Euston Road, London NW1 2BU, UK
| |
Collapse
|
29
|
Assi C, Caton J, Fawaz W, Samaha C, Yammine K. Revision total hip arthroplasty with a Kerboull plate: comparative outcomes using standard versus dual mobility cups. INTERNATIONAL ORTHOPAEDICS 2018; 43:2245-2251. [PMID: 30370452 DOI: 10.1007/s00264-018-4209-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Accepted: 10/18/2018] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Instability is a major complication in revision total hip arthroplasty (THA). Dual mobility (DM) cups were shown to reduce the risk of post-operative implant dislocation. Few case-series studies assessed the outcomes of cemented DM cups when associated to acetabular reconstruction antiprotrusio cages. No published comparative studies were found to look for outcome differences between standard cups (SC) and DM cups in first revision THA associated with a Kerboull plate (KP) and acetabular bone grafting. MATERIALS AND METHODS This is a retrospective comparative study of two groups of patients in two institutions. All cases were first revision THA with KP reconstruction; a cemented standard cup (SC) was used in one institution (THA-SC group) while a cemented DM cup was used in the second institution (THA-DM group). The posterolateral approach and the same technique for KP placement, the cross technique, were performed in both groups. Primary outcomes were dislocation and revision rates. Survivorship and clinical and radiological results were set to be secondary outcomes. There were ten patients (13 hips) in the first group and 16 patients (16 hips) in the second with a mean follow-up clinical and radiological evaluation of 74.2 ± 47.9 months. RESULTS Besides age, no significant demographic differences were present between both groups. There were three dislocations (23%) in the first group treated with close reduction compared to none in the second (p = 0.04). No further episode of dislocation or revision surgery occurred until the last follow-up in both groups. The mean Harris Hip Scores for the THA-SC and THA-DM groups were 87.5 ± 10.9 and 87.4 ± 12.1, respectively. When present, radiolucent lines were less than 1 mm thick and were non-progressive in both groups. In all patients, complete trabeculation remodeling or cortical repair of the graft was observed. CONCLUSION The cup type was the single variable which could account for the observed dislocation rate difference. The mid-term results of using DM cups with KP in first revision THA seem very encouraging. Our findings add to the previously published results on the excellent outcomes in terms of stability in revision THA when using DM cups.
Collapse
Affiliation(s)
- Chahine Assi
- Department of Orthopedic Surgery, Lebanese American University Medical Center-Rizk Hospital, Achrafieh, Beirut, Lebanon
| | | | - Wissam Fawaz
- Department of Orthopedic Surgery, Lebanese American University Medical Center-Rizk Hospital, Achrafieh, Beirut, Lebanon
| | - Camille Samaha
- Department of Orthopedic Surgery, Lebanese American University Medical Center-Rizk Hospital, Achrafieh, Beirut, Lebanon
| | - Kaissar Yammine
- Department of Orthopedic Surgery, Lebanese American University Medical Center-Rizk Hospital, Achrafieh, Beirut, Lebanon. .,Center for Evidence-Based Anatomy, Sports & Orthopedic Research, Beirut, Lebanon.
| |
Collapse
|
30
|
Neri T, Philippot R, Klasan A, Putnis S, Leie M, Boyer B, Farizon F. Dual mobility acetabular cups for total hip arthroplasty: advantages and drawbacks. Expert Rev Med Devices 2018; 15:835-845. [PMID: 30345834 DOI: 10.1080/17434440.2018.1538781] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
INTRODUCTION The dual mobility cup (DMC) concept was proposed by Professor Gilles Bousquet in 1974. Its' aims were to prevent postoperative dislocation, restore the physiological range of motion of the hip, and reduce the stresses at the interface. Since it was created, this design has been modified multiple times to reduce the complication rate, improve implant survival, and expand the indications. AREAS COVERED The objective of this review is to discuss the advantages and disadvantages of this implant based on its 40-year history and also to propose a range of indications based on published results. This will provide surgeons with a complete overview of DMC. EXPERT COMMENTARY Published studies on DMC confirm the low dislocation rate. Improvements made to DMC overtime have greatly reduced the complications related to wear, such as aseptic loosening and intraprosthetic dislocation (IPD). According to the literature, the indications have expanded and are no longer limited to revision surgery only. Long-term studies are needed before we can draw formal conclusions and consolidate these promising results.
Collapse
Affiliation(s)
- Thomas Neri
- a Department of Orthopaedic Surgery , University Hospital Centre of Saint-Etienne , Saint Etienne , France.,b EA 7424, Inter-university Laboratory of Human Movement Science , University Lyon, University Jean Monnet , Saint Etienne , France.,c Sydney Orthopaedic Research Institute , Sydney , Australia
| | - Remi Philippot
- a Department of Orthopaedic Surgery , University Hospital Centre of Saint-Etienne , Saint Etienne , France.,b EA 7424, Inter-university Laboratory of Human Movement Science , University Lyon, University Jean Monnet , Saint Etienne , France
| | - Antonio Klasan
- c Sydney Orthopaedic Research Institute , Sydney , Australia
| | - Sven Putnis
- c Sydney Orthopaedic Research Institute , Sydney , Australia
| | - Murilo Leie
- c Sydney Orthopaedic Research Institute , Sydney , Australia
| | - Bertrand Boyer
- a Department of Orthopaedic Surgery , University Hospital Centre of Saint-Etienne , Saint Etienne , France.,b EA 7424, Inter-university Laboratory of Human Movement Science , University Lyon, University Jean Monnet , Saint Etienne , France
| | - Frederic Farizon
- a Department of Orthopaedic Surgery , University Hospital Centre of Saint-Etienne , Saint Etienne , France.,b EA 7424, Inter-university Laboratory of Human Movement Science , University Lyon, University Jean Monnet , Saint Etienne , France
| |
Collapse
|
31
|
Benelli G, Maritato M, Cerulli Mariani P, Sasso F. Revision of ASR hip arthroplasty: analysis of two hundred and ninety six recalled patients at seven years. INTERNATIONAL ORTHOPAEDICS 2018; 43:97-101. [PMID: 30194652 DOI: 10.1007/s00264-018-4128-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Accepted: 08/21/2018] [Indexed: 12/26/2022]
Abstract
PURPOSE The aim of this study is to present an algorithm for the evaluation of both symptomatic and asymptomatic patients. METHODS From November 2004 to May 2010, there were performed 296 operations: 245 total hip arthroplasty and 51 resurfacing arthroplasty with the ASR DePuy system. In April 2010, there was the first Medical Device Alert regarding all MoM hip replacements in the UK and in August 2010, DePuy recall started worldwide. In March 2012, we started our recall. All patients were invited to undergo clinical investigation, X-ray evaluations, and blood chrome and cobalt level determination. For a short period of time, there were performed second level exams and subsequently, we carried out MARS MRI hip study to all symptomatic patients and there was evidence of ALVAL lesions. RESULTS To the patients with ALVAL lesions were proposed surgical hip revision while the others frequent follow-up controls. One hundred patients underwent hip surgical revision. CONCLUSIONS We recommend constant MoM THA patients monitoring and early revision if necessary.
Collapse
Affiliation(s)
- Giovanni Benelli
- Orthopaedic and Traumatology Department, Santo Stefano Hospital, Azienda USL Toscana Centro, Prato, Italy
| | - Merildo Maritato
- Orthopaedic and Traumatology Department, Santo Stefano Hospital, Azienda USL Toscana Centro, Prato, Italy
| | - Pierpaolo Cerulli Mariani
- Orthopaedic and Traumatology Department, Santo Stefano Hospital, Azienda USL Toscana Centro, Prato, Italy.
| | - Francesco Sasso
- Orthopaedic and Traumatology Department, Santo Stefano Hospital, Azienda USL Toscana Centro, Prato, Italy
| |
Collapse
|
32
|
|
33
|
Caton JH, Ferreira A. Dual-mobility cup: a new French revolution. INTERNATIONAL ORTHOPAEDICS 2017; 41:433-437. [PMID: 28197702 DOI: 10.1007/s00264-017-3420-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2017] [Accepted: 01/26/2017] [Indexed: 01/16/2023]
Affiliation(s)
| | - André Ferreira
- Clinique du Parc, 155 Ter Boulevard de Stalingrad, 69006, Lyon, France.
| |
Collapse
|
34
|
Röhner E, Matziolis G. [Use of dual mobility cups for revision hip arthroplasty]. DER ORTHOPADE 2017; 46:114-120. [PMID: 28097416 DOI: 10.1007/s00132-016-3383-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The dual mobility cup (DMC) is an increasingly important tool not only in primary but also in revision total hip arthroplasty to prevent dislocation and eventually reduce postoperative complication rates. Various studies have shown survival rates with DMCs of up to 100% with an average dislocation rate of less than 1.5% after primary hip arthroplasty and a follow-up of 10 years. In revision surgery, survival rates of up to 99% were reported with dislocation rates between 0 and 10% after an average of 5 years after implantation. This article is intended to provide an overview of the principle and function of DMCs. Furthermore, indications as well as complications are presented.
Collapse
Affiliation(s)
- E Röhner
- Orthopädische Klinik des Universitätsklinikums Jena am Campus Eisenberg, Waldkrankenhaus "Rudolf Elle" GmbH, Klosterlausnitzer Straße 81, 07607, Eisenberg, Deutschland.
| | - G Matziolis
- Orthopädische Klinik des Universitätsklinikums Jena am Campus Eisenberg, Waldkrankenhaus "Rudolf Elle" GmbH, Klosterlausnitzer Straße 81, 07607, Eisenberg, Deutschland
| |
Collapse
|