1
|
Lizcano JD, Marei S, Sharkey PF, Higuera-Rueda CA, Moskal JT, Clyburn TA, Suleiman LI, McGrory BJ. Does the Type of Femoral Stem and/or Femoral Head Influence the Rate of Adverse Local Tissue Reactions After Primary Total Hip Arthroplasty? J Arthroplasty 2024:S0883-5403(24)01066-0. [PMID: 39426440 DOI: 10.1016/j.arth.2024.10.051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2024] [Revised: 10/08/2024] [Accepted: 10/11/2024] [Indexed: 10/21/2024] Open
Affiliation(s)
- Juan D Lizcano
- Department of Orthopaedics Cleveland Clinic, Weston, Florida
| | - Sameh Marei
- Menoufia Orthopedic Surgery Department, Menoufia University Hospitals, Menoufia, Egypt
| | | | | | - Joseph T Moskal
- Department of Orthopaedics Carilion Clinic, Roanoke, Virginia
| | - Terry A Clyburn
- Department of Orthopaedics Houston Methodists, Houston, Texas
| | - Linda I Suleiman
- Department of Orthopaedics Northwestern Feinberg School of Medicine, Chicago, Illinois
| | - Brian J McGrory
- Department of Orthopaedics Tufts University School of Medicine, Boston, Massachusetts
| |
Collapse
|
2
|
Shen V, Andrews R, Binitie O, Palumbo BT. Possible Transformation of Pseudotumor to Synovial Sarcoma in a Failed Metal-on-Metal Total Hip Arthroplasty. Arthroplast Today 2024; 29:101408. [PMID: 39391234 PMCID: PMC11466573 DOI: 10.1016/j.artd.2024.101408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Revised: 04/19/2024] [Accepted: 04/27/2024] [Indexed: 10/12/2024] Open
Abstract
Adverse local tissue reaction (ALTR) from the release of chromium and cobalt ions in metal-on-metal total hip arthroplasty (MoM THA) is a well-reported complication, but there is little evidence suggesting that this inflammatory reaction causes malignancy. We present a 69-year-old female with MoM THA who developed synovial sarcoma (SS). She underwent mass resection and revision THA. Postoperative pathologic analysis revealed the unanticipated diagnosis of SS. She subsequently underwent chemotherapy, sarcoma resection, and endoprosthetic reconstruction. We hypothesize that the SS developed from an ALTR in the setting of failed MoM THA. Given the paucity of data on possible malignant transformation of an ALTR to SS, we advise surgeons to consider potential malignancies when diagnosing ALTR in the setting of failed MoM THA bearings.
Collapse
Affiliation(s)
- Victor Shen
- Department of Orthopaedic Surgery, University of Southern Florida Health Morsani College of Medicine, Tampa, FL, USA
| | - Reed Andrews
- Department of Orthopaedic Surgery, University of Southern Florida Health Morsani College of Medicine, Tampa, FL, USA
- Department of Orthopaedic Surgery, Florida Orthopaedic Institute, Tampa, FL, USA
| | - Odion Binitie
- Department of Orthopaedic Surgery, University of Southern Florida Health Morsani College of Medicine, Tampa, FL, USA
- Department of Orthopaedic Surgery, Moffitt Cancer Center, Tampa, FL, USA
| | - Brian T. Palumbo
- Department of Orthopaedic Surgery, University of Southern Florida Health Morsani College of Medicine, Tampa, FL, USA
- Department of Orthopaedic Surgery, Florida Orthopaedic Institute, Tampa, FL, USA
| |
Collapse
|
3
|
Min M, Xing C, Xu P, Wei X, Fan L. Case report: Formation and recurrence of inflammatory pseudotumor after metal-on-metal hip arthroplasty. Front Med (Lausanne) 2024; 11:1422230. [PMID: 39055697 PMCID: PMC11269118 DOI: 10.3389/fmed.2024.1422230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Accepted: 06/17/2024] [Indexed: 07/27/2024] Open
Abstract
The metal-on-metal (MoM) artificial hip joint is a prosthesis used in early hip arthroplasty, particularly for hip resurfacing and total hip arthroplasty. However, abrasion and corrosion of MoM bearings result in the production of metal ions, such as cobalt and chromium, thereby inducing several complications such as inflammatory pseudotumor, aseptic inflammation, and allergy to metal ions (delayed type IV hypersensitivity). In this case report, we present a patient who was hospitalized for recurrence of a mass in the right inguinal area. In 2010, the patient underwent right MoM total hip arthroplasty for right femoral head necrosis and exhibited a good postoperative recovery. In 2019, the patient experienced pain in the right hip with activity limitation without any evident triggers, and a palpable mass was observed in the right inguinal area. A large periprosthetic mass was resected under general anesthesia, and the patient recovered well after the operation. Based on post-surgery imaging and pathological examinations, the mass was diagnosed as a periprosthetic inflammatory pseudotumor. In 2021, the inflammatory pseudotumor recurred at the same site. He then underwent right total hip revision surgery under epidural anesthesia and recovered well after surgery. No recurrence was noted at moderate follow-up. The incidence of inflammatory pseudotumors is high in MoM hip arthroplasty. Early revision is necessary in patients who meet the indications for revision, while regular postoperative follow-up is crucial.
Collapse
Affiliation(s)
| | | | | | | | - Lei Fan
- Department of Orthopedics, The Second Affiliated Hospital of Nanjing Medical University, Nanjing, China
| |
Collapse
|
4
|
Al-Khatib Y, Tyas B, Kalson NS, Agni N, Bhutani P, Petheram T, Carluke I, Partington P. Quantification and severity grading of femoral vessel compression by adverse reactions to metal debris in metal-on-metal total hip arthroplasty. Hip Int 2024; 34:215-220. [PMID: 37545332 DOI: 10.1177/11207000231190738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/08/2023]
Abstract
INTRODUCTION Metal-on-metal (MoM) total hip arthroplasty (THA) may cause adverse reactions to metal debris (ARMD). ARMD causing femoral vessel compression with serious complications has been described in case reports, but the rate of compression by ARMD is not known. This study aims to investigate the rate, and quantify the severity, of femoral vessel compression in MoM hips with ARMD lesions. METHODS Patients under surveillance for MoM THA investigated with MRI were studied. In patients with confirmed ARMD, femoral artery (FA) and vein (FV) diameters were measured at the point of maximal compression and compared to contralateral vessels. The primary outcome measure was presence or absence of compression. Cases were then classified by compression ratios. Secondary outcome measures were rates of deep vein thrombosis, revision surgery and time to ARMD from index procedure. RESULTS MRI scans for 436 patients with MoM THA were screened. Of these, 211/436 (48.4%) showed evidence of ARMD. Measurements were obtained on 133/211 (63.0%) patients. The FV was compressed in 102/133 (76.7%) and FA in 58/133 (43.6%), while 31/133 (23.3%) patients had no compression. In FVs, 42 demonstrated mild compression, 39 moderate and 21 severe. In FAs, none were severely compressed, 6 were moderate and 52 showed mild compression. There were 3 DVT cases, 2 in patients with moderate FV compression and 1 in patients without FV compression. Revision rates were highest in patients with severe FV compression (14/21, 66.7%). The mean time for MRI-diagnosed ARMD from index procedure was 8 years and 1 month (range 11 months-14.5 years). CONCLUSIONS Extra-luminal compression of the femoral vessels was found in >75% of patients with ARMD. Although it is not clear whether revision for femoral vessel compression is required, quantification of FV compression may be useful for surgeons and radiologists considering revision for ARMD.
Collapse
Affiliation(s)
| | - Ben Tyas
- Trauma and Orthopaedics, Health Education North East, Newcastle Upon Tyne, UK
| | - Nicholas S Kalson
- Department of Orthopaedics, Northumbria Healthcare NHS Foundation Trust, Newcastle Upon Tyne, UK
| | - Nickil Agni
- Department of Orthopaedics, Northumbria Healthcare NHS Foundation Trust, Newcastle Upon Tyne, UK
| | - Priyesh Bhutani
- Department of Radiology, Northumbria Healthcare NHS Foundation Trust, Newcastle Upon Tyne, UK
| | - Timothy Petheram
- Department of Orthopaedics, Northumbria Healthcare NHS Foundation Trust, Newcastle Upon Tyne, UK
| | - Ian Carluke
- Department of Orthopaedics, Northumbria Healthcare NHS Foundation Trust, Newcastle Upon Tyne, UK
| | - Paul Partington
- Department of Orthopaedics, Northumbria Healthcare NHS Foundation Trust, Newcastle Upon Tyne, UK
| |
Collapse
|
5
|
Lucaci FD, Battiato P, Bassi J, Zani DD, De Zani D, Vezzoni A, Stranieri A, Longo M. Radiographic and CT features of metallosis in a lame dog after total hip replacement: the cloud sign. Vet Radiol Ultrasound 2024; 65:49-53. [PMID: 38131525 DOI: 10.1111/vru.13322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 11/21/2023] [Accepted: 11/22/2023] [Indexed: 12/23/2023] Open
Abstract
A 2-year-old female American Akita was referred for CT of the pelvis and hindlimbs due to a left hindlimb lameness after a left total hip replacement. Referral radiographs and CT images demonstrated amorphous soft-tissue and mineral opacities surrounding the proximal femur and the prosthetic stem, consistent with the "cloud sign" reported as a characteristic of metallosis in humans. Dorsomedial displacement of the prosthetic head, multiple foci of geographic osteolysis alongside the "cloud sign", presumed pseudotumor lesions, and medial iliac lymphadenopathy were also identified with CT. Metallosis was confirmed based on ultrasound-guided cytology, revision surgery, and histopathology.
Collapse
Affiliation(s)
- Felix Daniel Lucaci
- Faculty of Veterinary Medicine, University of Agricultural Sciences and Veterinary Medicine, Cluj-Napoca, Romania
| | - Pierantonio Battiato
- Department of Veterinary Medicine and Animal Sciences, University of Milan, Lodi, Italy
| | - Jessica Bassi
- Department of Veterinary Medicine and Animal Sciences, University of Milan, Lodi, Italy
| | - Davide Danilo Zani
- Department of Veterinary Medicine and Animal Sciences, University of Milan, Lodi, Italy
| | - Donatella De Zani
- Department of Veterinary Medicine and Animal Sciences, University of Milan, Lodi, Italy
| | | | - Angelica Stranieri
- Department of Veterinary Medicine and Animal Sciences, University of Milan, Lodi, Italy
| | - Maurizio Longo
- Department of Veterinary Medicine and Animal Sciences, University of Milan, Lodi, Italy
| |
Collapse
|
6
|
Holappa E, Kettunen J, Miettinen H, Kröger H, Miettinen S. Long-term survival analysis of cementless large-diameter head metal-on-metal total hip arthroplasty. Arch Orthop Trauma Surg 2023; 143:4437-4446. [PMID: 36197490 PMCID: PMC10293397 DOI: 10.1007/s00402-022-04633-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Accepted: 09/18/2022] [Indexed: 11/30/2022]
Abstract
INTRODUCTION The aim of this retrospective study was to study the long-term survival and reasons for revisions of a single-type, large-diameter head (LDH) metal-on-metal (MoM) implant. A special study interest was to find the threshold level for revision in terms of adverse reaction to metal debris (ARMD). MATERIALS AND METHODS In this cohort study, we retrospectively reviewed 234 patients (253 hips) who received 38 mm head size LDH MoM total hip arthroplasties (THAs) between 01 January 2004 and 31 December 2009 at our institution. Patient symptoms, conventional radiographs, magnetic resonance imaging (MRI) findings and whole blood metal ions were studied. RESULTS The median follow-up time was 11.5 years. The Kaplan-Meier cumulative survival estimate of the implant was 89.6% at 10 years and 82.9% at 14.6 years. Overall, 34/253 (13.4%) hips were revised during the follow-up period and of these; 19/34 (55.9%) were revised due to ARMD. The prevalence of ARMD was 12.4% (29/234 patients). CONCLUSIONS The survival of the implant was on a moderate level as the 10-year cumulative survival rate was 89.6%. The exact threshold level for ARMD revision cannot be determined due to multiple variables affecting factors in re-operation decision-making.
Collapse
Affiliation(s)
- Elli Holappa
- Faculty of Health Sciences, University of Eastern Finland, Yliopistonranta 1, 70210, Kuopio, Finland
| | - Jukka Kettunen
- Department of Orthopaedics, Traumatology and Hand Surgery, Kuopio University Hospital, PO Box 1777, 70211, Kuopio, Finland
| | - Hannu Miettinen
- Department of Orthopaedics, Traumatology and Hand Surgery, Kuopio University Hospital, PO Box 1777, 70211, Kuopio, Finland
| | - Heikki Kröger
- Department of Orthopaedics, Traumatology and Hand Surgery, Kuopio University Hospital, PO Box 1777, 70211, Kuopio, Finland
- Faculty of Health Sciences, University of Eastern Finland, Yliopistonranta 1, 70210, Kuopio, Finland
| | - Simo Miettinen
- Department of Orthopaedics, Traumatology and Hand Surgery, Kuopio University Hospital, PO Box 1777, 70211, Kuopio, Finland.
- Faculty of Health Sciences, University of Eastern Finland, Yliopistonranta 1, 70210, Kuopio, Finland.
| |
Collapse
|
7
|
Wu D, Bhalekar RM, Marsh JS, Langton DJ, Stewart AJ. Periarticular metal hypersensitivity complications of hip bearings containing cobalt-chromium. EFORT Open Rev 2022; 7:758-771. [PMID: 36475551 PMCID: PMC9780614 DOI: 10.1530/eor-22-0036] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Hip joints with bearings composed of cobalt-chromium alloy (metal-on-metal bearings) have been one of the most widely used implants in joint replacement arthroplasty. Unfortunately, these implants can contribute to a complication called aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL), a type IV metal hypersensitivity response around the joint. Consistent with such bearings, increased metal debris can be found in the surrounding fluids and in remote tissues and organs, due to wear and corrosion. It is hypothesized that metal ions released from the prosthesis (including Co2+) can potentially form haptens with proteins such as serum albumin in synovial fluid that in turn elicit ALVAL. Generally, elevated cobalt and chromium levels in synovial fluids may indicate implant failure. However, such measurements cannot be used as a reliable tool to predict the onset of ALVAL. To detect ALVAL, some diagnostic tests, questionnaires and imaging techniques have been used clinically with some success, but a standardized approach is lacking. At present, guidelines for implant usage and patient management are ambiguous and inconsistent across health care authorities. To reduce and better manage the development of ALVAL, further research into the precise molecular mechanism(s) by which ALVAL develops is urgently needed. Identification of diagnostic and prognostic biomarkers for ALVAL is required, as are more standardized guidelines for surgery and patient management.
Collapse
Affiliation(s)
- Dongmei Wu
- School of Medicine, University of St. Andrews, St. Andrews, Fife, United Kingdom
| | - Rohan M Bhalekar
- ExplantLab, The Biosphere, Newcastle Helix, Newcastle-upon-Tyne, United Kingdom
| | - Jordan S Marsh
- School of Medicine, University of St. Andrews, St. Andrews, Fife, United Kingdom
| | - David J Langton
- ExplantLab, The Biosphere, Newcastle Helix, Newcastle-upon-Tyne, United Kingdom
| | - Alan J Stewart
- School of Medicine, University of St. Andrews, St. Andrews, Fife, United Kingdom,Correspondence should be addressed to A J Stewart;
| |
Collapse
|
8
|
Ikeda S, Kaku N, Hosoyama T, Tsumura H. Survival rates of different bearing surfaces with the same model of stem in total hip arthroplasty: predictive factors for revision surgery. Arch Orthop Trauma Surg 2022:10.1007/s00402-022-04706-9. [PMID: 36443614 DOI: 10.1007/s00402-022-04706-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 11/21/2022] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Few studies have examined the survival rates of total hip arthroplasty (THA) with the same femoral stem, and the predictive factors leading to the revision of stemmed metal-on-metal (MoM) THA remain unknown. We determined the long-term survival rate of stemmed MoM THA compared with that of metal-on-polyethylene (MoP) bearing THA, the effect of head size and cup placement angle on revision rate, and predictors of revision. MATERIALS AND METHODS A total of 130 hips in 110 patients who underwent primary THA by the same surgeon were included. M2a-RingLoc with a metal-on-polyethylene bearing (group P, 53 hips), M2a-Taper with MoM bearing (group T, 44 hips), and M2a-Magnum with MoM bearing (group M, 33 hips) were used. The mean age at surgery was 63.1 ± 9.5 years, and the mean postoperative follow-up duration was 133.7 ± 39.1 months. Whole blood metal ion concentrations were measured preoperatively and postoperatively, and magnetic resonance imaging was performed to identify aseptic local tissue reactions (ALTRs). Kaplan-Meier survivorship analysis and multiple logistic regression analysis were performed. RESULTS The THA survival rate up to the maximum postoperative follow-up period was 96.2% at 173 months, 46.6% at 179 months, and 47.8% at 145 months in groups P, T, and M, respectively, with revision as the endpoint. The stemmed MoM THA recorded a very low survival rate (p < 0.001). The ALTR rates were 70.5% and 63.6% in groups T and M, respectively. The risk factor for revision was the use of MoM bearing, and there was no difference in the results based on the head size in group M. Cobalt levels continued to increase postoperatively, although they were not accurate predictors of revision. CONCLUSIONS Stemmed MoM THA has a very low survival rate and should be used with caution. It is important to monitor the patient's symptoms and perform appropriate imaging to ensure timely revision.
Collapse
Affiliation(s)
- Shinichi Ikeda
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, 1-1 Idaigaoka Hasama-Machi, Yufu, Oita, 879-5593, Japan
| | - Nobuhiro Kaku
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, 1-1 Idaigaoka Hasama-Machi, Yufu, Oita, 879-5593, Japan.
| | - Tsuguaki Hosoyama
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, 1-1 Idaigaoka Hasama-Machi, Yufu, Oita, 879-5593, Japan
| | - Hiroshi Tsumura
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, 1-1 Idaigaoka Hasama-Machi, Yufu, Oita, 879-5593, Japan
| |
Collapse
|
9
|
Rahman TM, Hall DJ, Darrith B, Liu S, Jacobs JJ, Pourzal R, Silverton CD. Non-ischaemic cardiomyopathy associated with elevated serum cobalt and accelerated wear of a metal-on-metal hip resurfacing. BMJ Case Rep 2022; 15:e249070. [PMID: 35760505 PMCID: PMC9237908 DOI: 10.1136/bcr-2022-249070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/09/2022] [Indexed: 11/04/2022] Open
Abstract
A man in his late 30s developed non-ischaemic cardiomyopathy due to systemic cobalt toxicity associated with accelerated bearing surface wear from metal-on-metal hip resurfacing implanted in the previous 6 years. Following revision arthroplasty, the patient regained baseline cardiac function. Cobalt-induced cardiomyopathy is a grave condition that deserves early consideration due to potentially irreversible morbidity. We present this case to increase awareness, facilitate early detection and emphasise the need for research into the diagnosis and management of at-risk patients.
Collapse
Affiliation(s)
- Tahsin M Rahman
- Orthopaedic Surgery, Henry Ford Health System, Detroit, Michigan, USA
| | - Deborah J Hall
- Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| | - Brian Darrith
- Orthopaedic Surgery, Henry Ford Health System, Detroit, Michigan, USA
| | - Songyun Liu
- Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| | - Joshua J Jacobs
- Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| | - Robin Pourzal
- Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| | - Craig D Silverton
- Orthopaedic Surgery, Henry Ford Health System, Detroit, Michigan, USA
| |
Collapse
|
10
|
van Lingen CP, Ettema HB, Bosker BH, Verheyen CCPM. Ten-year results of a prospective cohort of large-head metal-on-metal total hip arthroplasty. Bone Jt Open 2022; 3:61-67. [PMID: 35043691 PMCID: PMC9047076 DOI: 10.1302/2633-1462.31.bjo-2021-0159.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Aims Large-diameter metal-on-metal (MoM) total hip arthroplasty (THA) has demonstrated unexpected high failure rates and pseudotumour formation. The purpose of this prospective cohort study is to report ten-year results in order to establish revision rate, prevalence of pseudotumour formation, and relation with whole blood cobalt levels. Methods All patients were recalled according to the guidelines of the Dutch Orthopaedic Association. They underwent clinical and radiographical assessments (radiograph and CT scan) of the hip prosthesis and whole blood cobalt ion measurements. Overall, 94 patients (95 hips) fulfilled our requirements for a minimum ten-year follow-up. Results Mean follow-up was 10.9 years (10 to 12), with a cumulative survival rate of 82.4%. Reason for revision was predominantly pseudotumour formation (68%), apart from loosening, pain, infection, and osteolysis. The prevalence of pseudotumour formation around the prostheses was 41%, while our previous report of this cohort (with a mean follow-up of 3.6 years) revealed a 39% prevalence. The ten-year revision-free survival with pseudotumour was 66.7% and without pseudotumour 92.4% (p < 0.05). There was poor discriminatory ability for cobalt for pseudotumour formation. Conclusion This prospective study reports a minimum ten-year follow-up of large-head MoM THA. Revision rates are high, with the main reason being the sequelae of pseudotumour formation, which were rarely observed after five years of implantation. Blood ion measurements show limited discriminatory capacity in diagnosing pseudotumour formation. Our results evidence that an early comprehensive follow-up strategy is essential for MoM THA to promptly identify and manage early complications and revise on time. After ten years follow-up, we do not recommend continuing routine CT scanning or whole cobalt blood measurements, but instead enrolling these patients in routine follow-up protocols for THA. Cite this article: Bone Jt Open 2022;3(1):61–67.
Collapse
Affiliation(s)
- Christiaan P. van Lingen
- Department of Orthopaedic Surgery and Traumatology, Medisch Spectrum Twente, Enschede, Overijssel, Netherlands
| | - Harmen B. Ettema
- Department of Orthopaedic Surgery and Traumatology, Isala, Zwolle, Overijssel, Netherlands
| | - Bart H. Bosker
- Department of Orthopaedic Surgery, Sint Maartenskliniek, Nijmegen, Gelderland, Netherlands
| | - Cees C. P. M. Verheyen
- Department of Orthopaedic Surgery and Traumatology, Isala, Zwolle, Overijssel, Netherlands
| |
Collapse
|
11
|
Yamashita A, Takeda Y, Fukui T, Tachibana T, Fukunishi S. Revision Total Hip Arthroplasty due to Catastrophic Osteolysis Caused by Massive Chronic Expanding Hematoma. Arthroplast Today 2021; 11:32-37. [PMID: 34458531 PMCID: PMC8377491 DOI: 10.1016/j.artd.2021.04.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 04/24/2021] [Accepted: 04/27/2021] [Indexed: 11/12/2022] Open
Abstract
An 84-year-old woman who underwent bilateral cementless total hip arthroplasty (THA) for dysplastic osteoarthritis 22 years ago was subjected to analysis. A huge soft-tissue mass was revealed in her left medial thigh. Plain radiographs of the left hip joint revealed severe osteolysis around the stem, cup, and ischium. Magnetic resonance imaging showed a 25 × 14-cm multilobulated mass with a thick-walled pseudocapsule. Two-stage surgery was performed with resection of the mass followed by a subsequent revision THA. The mass was diagnosed as a chronic expanding hematoma through gross and histologic findings. Two years after the revision THA, there was no recurrence of a hematoma. Two-stage revision THA was useful for definitive diagnosis, and good functional recovery was obtained after surgery.
Collapse
Affiliation(s)
- Akihiro Yamashita
- Department of Orthopedic Surgery, Nishinomiya Kaisei Hospital, Nishinomiya City, Hyogo, Japan
| | - Yu Takeda
- Department of Orthopedic Surgery, Nishinomiya Kaisei Hospital, Nishinomiya City, Hyogo, Japan
| | - Tomokazu Fukui
- Department of Orthopedic Surgery, Hyogo College of Medicine, Nishinomiya City, Hyogo, Japan
| | - Toshiya Tachibana
- Department of Orthopedic Surgery, Hyogo College of Medicine, Nishinomiya City, Hyogo, Japan
| | - Shigeo Fukunishi
- Department of Orthopedic Surgery, Nishinomiya Kaisei Hospital, Nishinomiya City, Hyogo, Japan
| |
Collapse
|
12
|
Kolbitsch P, Noebauer-Huhmann IM, Giurea A, Kubista B, Windhager R, Lass R. Pseudotumors in Small-Head Metal-on-Metal Total Hip Arthroplasties at a Minimum Follow-Up of 20 Years. J Arthroplasty 2021; 36:2871-2877. [PMID: 33812711 DOI: 10.1016/j.arth.2021.03.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Revised: 02/28/2021] [Accepted: 03/05/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Metal-on-metal (MOM) surfaces in total hip arthroplasty (THA) have been used widely. Serum cobalt and chromium levels have been the standard investigation for follow-up examinations, but magnetic resonance imaging (MRI) with metal artifact reducing sequences has shown good results in detecting pseudotumors. The aim of this study is to survey a significant correlation among MRI findings, serum metal levels, and clinical scores in patients with small-head MOM implants and if serum cobalt and chromium levels are sufficient in detecting patients with pseudotumors in the long-term follow-up. METHODS At a minimum follow-up of 20 years, 26 patients (29 THAs) of the original 98 patients (105 THAs) included in this study between November 1992 and May 1994 were available for follow-up examination. Clinical scores, serum metal ion levels, and MRIs were obtained. RESULTS We found mean serum cobalt levels of 1.87 μg/L (±3.44) and chromium levels of 2.23 μg/L (±2.96) and very good clinical and functional results (mean Harris Hip Score 88.6) in the long-term follow-up. Pseudotumors were detected in MRIs of 21 hips. There were no significant differences between patients with or without pseudotumors regarding serum metal levels and the correlation for clinical outcome scores, demographic data, and cup inclination. The cumulative rate of survival was still at 91.4% at 22.8 years. CONCLUSION This study presents the first published data on small-head MOM hips, comparing metal ion levels, pseudotumors, clinical, and radiological results in a follow-up period of more than 20 years and reveals that serum metal levels are not significantly higher in patients with pseudotumors. LEVEL OF EVIDENCE Therapeutic Level III.
Collapse
Affiliation(s)
- Paul Kolbitsch
- Division of Orthopedics, Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Vienna, Austria
| | - Iris-Melanie Noebauer-Huhmann
- Division of Neuroradiology and Musculoskeletal Radiology, Department of Radiology, Medical University of Vienna, Vienna, Austria
| | - Alexander Giurea
- Division of Orthopedics, Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Vienna, Austria
| | - Bernd Kubista
- Division of Orthopedics, Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Vienna, Austria
| | - Reinhard Windhager
- Division of Orthopedics, Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Vienna, Austria
| | - Richard Lass
- Division of Orthopedics, Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
13
|
Coutandin M, Afghanyar Y, Drees P, Dargel J, Rehbein P, Kutzner KP. Can hip resurfacing be safely revised with short-stem total hip arthroplasty? A case series of six patients. J Orthop 2021; 24:274-279. [PMID: 33897129 PMCID: PMC8050111 DOI: 10.1016/j.jor.2021.03.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 03/21/2021] [Indexed: 01/15/2023] Open
Abstract
BACKGROUND The usage of short stems in primary total hip arthroplasty (THA) has constantly gained popularity over the last decade, however, to date, short stems are not eligible to be used as revision implants. The aim of this study was to retrospectively evaluate the outcome of revision surgery of failed hip resurfacing arthroplasty (HRA) using short-stem THA. METHODS In a single center, retrospective analysis, 6 consecutive patients who were treated with a calcar-guided short stem after failure of HRA were evaluated. The mean follow-up was 3.25 years (SD 0.45). Patient reported outcome measurements (PROMs) were recorded using the Harris hip score (HHS) and The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). The health status was evaluated by the EQ-5D-5L score. Pain and satisfaction were obtained using the visual analogue scale (VAS). Radiographic analysis was performed by evaluating osteolysis, stress shielding, alignement and signs of aseptic loosening. Complications were documented. RESULTS At last follow-up, clinical outcome was excellent (HHS ≥ 90) in 5 patients and good (HHS = 87) in 1 patient. The mean WOMAC score was 5.73% (SD 3.66%). The mean EQ-5D-5L index was 0.914 (SD 0.07). Pain and satisfaction on VAS was 1.83 (SD 5.18) and 8.67 (SD 0.94), respectively. Radiologically, no signs of subsidence, aseptic loosening, stress shielding and fracture were obvious. No major complications occurred. To date, no further revision surgery was needed. CONCLUSIONS The outcomes of the present case series propose that HRA can be safely revised using short-stem THA in a selected patient group. Clinical and radiological results are encouraging. Based on the present data, short stems may be considered as a revision implant for failed HRA for experienced surgeons.
Collapse
Affiliation(s)
- Marcel Coutandin
- Department of Orthopaedics and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Yama Afghanyar
- Department of Orthopaedics and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Philipp Drees
- Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Langenbeckstraße 1, 55131, Mainz, Germany
| | - Jens Dargel
- Department of Orthopaedics and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Philipp Rehbein
- Department of Orthopaedics and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Karl Philipp Kutzner
- Department of Orthopaedics and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
- Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Langenbeckstraße 1, 55131, Mainz, Germany
| |
Collapse
|
14
|
Incidence of Pseudotumors in a Dual Modular Stem Construct With and Without Metal-on-Metal Bearing Surface. J Am Acad Orthop Surg 2021; 29:e92-e97. [PMID: 32568995 DOI: 10.5435/jaaos-d-19-00652] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The purpose of this study was to compare the incidence of pseudotumors in metal-on-metal (MoM) titanium modular neck hip arthroplasties to non-MoM modular neck hip arthroplasties. A secondary goal was to determine whether a correlation exists between elevated metal concentrations and pseudotumor incidence. METHODS The data were collected and evaluated from 49 MoM joints and 26 non-MoM joints between the years 2012 and 2017. Hip ultrasonography was done after a minimum of 5 years postimplantation. Whole serum metal (titanium, cobalt, and chromium) concentrations were measured at the hip ultrasonography study. RESULTS The average time elapsed between surgery and ultrasonography visit was 7.6 years. In the 49 patients with MoM joints, 22.4% (n = 11) had a pseudotumor. In the 26 patients with non-MoM joints, 9.1% of metal-on-polyethylene hips (n = 1) and 0% of ceramic-on-ceramic/polyethylene hips developed a pseudotumor. No significant statistical correlation was observed between serum metal concentrations and pseudotumor formation (P > 0.05). A significant correlation was observed of serum titanium concentration to pseudotumor size (P = 0.024). CONCLUSION The incidence of pseudotumor formation in MoM total hip arthroplasties was more than five times the incidence associated with non-MoM bearings. The correlation between serum titanium concentration and pseudotumor size suggests that titanium levels may be a useful indicator for pseudotumor formation in patients with this particular titanium modular neck femoral implant. No notable correlation was observed between serum cobalt and chromium concentration and pseudotumor formation or size.
Collapse
|
15
|
Cushnie DW, Lanting BA, McCalden R, Naudie DD, Howard JL. Midterm outcomes of total hip arthroplasty with a modular Birmingham head. Hip Int 2021; 31:103-108. [PMID: 31530026 DOI: 10.1177/1120700019877389] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Birmingham Hip Resurfacing (BHR) implants may be combined with a conventional femoral stem to create a modular metal-on-metal total hip arthroplasty (BHR MoM THA). There is little outcome data regarding this construct. This study examines midterm outcomes of BHR MoM THA compared to oxidised zirconium total hip arthroplasty (THA). METHODS A retrospective institutional review identified all patients receiving BHR MoM THA between April 2005 and February 2011 and a matched control cohort of zirconium THA patients. Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS), and SF-12 Health status scores were obtained. Revisions and complications were collected from clinical records. Radiographs were assessed for evidence of component malposition, loosening, osteolysis, or heterotopic ossification. RESULTS 63 modular BHR MoM THA were identified in 61 patients (36 with BHR cups, 27 with R3 cups) and 63 zirconium THA in 58 matched controls. Mean follow-up was 58 months. 14 BHR MoM THA hips (22.2%) were revised (4 infections, 1 dislocation, 9 soft tissue reactions) compared to 3 (4.8%) zirconium THA (all infections). At latest follow-up, 18.4% of surviving BHR MoM THA hips were painful compared to 0.5% of zirconium THA controls (p < 0.001). WOMAC, HHS, and SF-12 did not differ significantly between surviving members of the 2 groups. DISCUSSION BHR MoM THA demonstrated a high revision rate, largely for adverse local soft tissue reaction and pain. Among those not revised, many reported some residual pain despite similar quality of life measures to those who received zirconium THA.
Collapse
Affiliation(s)
- Duncan W Cushnie
- Division of Orthopaedic Surgery, London Health Sciences Centre and Western University, London, Canada.,Department of Surgery, McMaster University, Hamilton, Canada
| | - Brent A Lanting
- Division of Orthopaedic Surgery, London Health Sciences Centre and Western University, London, Canada
| | - Richard McCalden
- Division of Orthopaedic Surgery, London Health Sciences Centre and Western University, London, Canada
| | - Douglas Dr Naudie
- Division of Orthopaedic Surgery, London Health Sciences Centre and Western University, London, Canada
| | - James L Howard
- Division of Orthopaedic Surgery, London Health Sciences Centre and Western University, London, Canada
| |
Collapse
|
16
|
Best Practices: Best Imaging Modality for Surveillance of Metal-on-Metal Hip Arthroplasty. AJR Am J Roentgenol 2020; 216:311-317. [PMID: 33325734 DOI: 10.2214/ajr.19.22344] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE. Metal-on-metal hip arthroplasty has been shown to result in soft-tissue complications in some patients, making revision surgery necessary. Imaging is critical in the detection and surveillance of soft-tissue complications, which are collectively termed adverse reaction to metal debris (ARMD) and adverse local tissue reaction. Studies have investigated the use of ultrasound, MRI, and CT for detecting ARMD, and each modality has advantages and disadvantages. This article provides evidence-based recommendations for imaging surveillance of ARMD. CONCLUSION. Compared with ultrasound, MRI has been found to be a better imaging modality for surveillance of ARMD. In addition, MRI is not operator dependent, allows visualization of soft-tissue details, and allows more consistent measurement of fluid collections on follow-up examinations. Limitations of ultrasound include operator skill, the inability to visualize osseous structures, and the challenge of visualizing posterior soft tissues for synovitis and fluid collections in larger patients. Finally, CT is only useful for focused evaluation of osteolysis or periprosthetic fracture.
Collapse
|
17
|
Wolfson M, Curtin P, Curry EJ, Cerda S, Li X. Giant cell tumor formation due to metallosis after open latarjet and partial shoulder resurfacing. Orthop Rev (Pavia) 2020; 12:8522. [PMID: 32922698 PMCID: PMC7461641 DOI: 10.4081/or.2020.8522] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Accepted: 04/16/2020] [Indexed: 11/23/2022] Open
Abstract
Shoulder metallosis with giant cell tumor formation is rarely seen in shoulder surgery. With an increase in shoulder arthroplasty and complex revision shoulder surgeries, clinicians should have an index of suspicion for possible metallosis in patients that presents with unexplained persistent pain with metal components on both the glenoid and humeral side. This case describes a 43-yearold female with a history of six prior shoulder surgeries who presented with shoulder metallosis and giant cell tumor formation after a screw from her open Latarjet procedure began rubbing against her Hemicap implant. She successfully underwent a revision total shoulder arthroplasty for post traumatic arthritis with pectoralis major transfer for her chronic subscapularis rupture and had complete symptom resolution.
Collapse
Affiliation(s)
- Matthew Wolfson
- Department of Orthopedic Surgery, Boston University School of Medicine, Boston, MA
| | - Patrick Curtin
- Department of Orthopedic Surgery, University of Massachusetts Medical School, Worcester, MA
| | - Emily J Curry
- Boston University School of Public Health, Boston, MA
| | - Sandra Cerda
- Department of Pathology, Boston University of School of Medicine, Boston, MA, USA
| | - Xinning Li
- Department of Orthopedic Surgery, Boston University School of Medicine, Boston, MA
| |
Collapse
|
18
|
Vendittoli PA, Massé V, Kiss MO, Lusignan D, Lavigne M. Modular junction may be more problematic than bearing wear in metal-on-metal total hip arthroplasty. Hip Int 2019; 29:262-269. [PMID: 30378457 DOI: 10.1177/1120700018808696] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION In total hip arthroplasty (THA), local adverse reaction to metal debris (ARMD) may be caused by abnormal metal ion release from a metal-on-metal (MoM) bearing, or by wear and corrosion of the implant's modular junction. The aim of this study was to compare ion levels and rate of ARMD between patients sharing the same MoM bearing but 1 group having monoblock stems versus another having modular stems. MATERIALS AND METHODS Whole blood cobalt (Co) and chromium (Cr) ion concentrations, ARMD rate, revision rate, and function measured by UCLA and WOMAC scores were compared between groups. RESULTS ARMD rate was significantly higher in the modular group (46%) compared with the monoblock group (16%, p = 0.031). Revision for ARMD was performed at 52.8 ± 8.1 months in the modular group versus 98.2 ± 15.5 months after primary THA in the monoblock group. ARMD originated from wear and corrosion of the junction between stem and femoral head adapter sleeve in all monoblock cases, and the junction between stem and modular neck in all the modular ones. Cr and Co ions levels were significantly higher in the modular stem group ( p < 0.001 for both). CONCLUSIONS Although both groups had MoM bearings, corrosion at stem/neck or neck/head junctions combining dissimilar metal (Ti and Cr-Co) was seen as the source of excess metal ions release leading to ARMD. Poor performance of the modular junction may be more deleterious than wear of the bearing. To avoid such complications, THA femoral stem modular junctions should be eliminated (return to a full monoblock implant) or have improved junction design.
Collapse
Affiliation(s)
- Pascal-André Vendittoli
- Department of Surgery, University of Montreal, Hospital Maisonneuve-Rosemont, Montreal, Canada
| | - Vincent Massé
- Department of Surgery, University of Montreal, Hospital Maisonneuve-Rosemont, Montreal, Canada
| | - Marc-Olivier Kiss
- Department of Surgery, University of Montreal, Hospital Maisonneuve-Rosemont, Montreal, Canada
| | - Daniel Lusignan
- Department of Surgery, University of Montreal, Hospital Maisonneuve-Rosemont, Montreal, Canada
| | - Martin Lavigne
- Department of Surgery, University of Montreal, Hospital Maisonneuve-Rosemont, Montreal, Canada
| |
Collapse
|
19
|
Loures E, Loures D, Castro e Silva A, Monte L. Pseudotumor em artroplastia total do quadril metal-metal com cabeça de grande diâmetro. Rev Bras Ortop 2019; 54:87-89. [PMID: 31363250 PMCID: PMC6415504 DOI: 10.1016/j.rbo.2017.06.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2017] [Accepted: 06/06/2017] [Indexed: 11/26/2022] Open
Abstract
The authors describe a case of a large diameter head metal-on-metal total hip replacement that evolved with an inflammatory pseudotumor formation. The diagnosis was established by magnetic resonance imaging (MRI) with suppression of the metal artifact. The treatment consisted on the resection of the abnormal tissue and on the revision to a ceramic on cross-linked polyethylene hip replacement. To this date, no similar case has been reported, in Portuguese language, in the PubMed, Scielo, and Lilacs databases.
Collapse
Affiliation(s)
- Elmano Loures
- Universidade Federal de Juiz de Fora (UFJF), Hospital Universitário, Juiz de Fora, Brasil
| | - Daniel Loures
- Universidade de São Paulo (USP), Hospital das Clinicas, Ribeirão Preto, Brasil
| | - Armando Castro e Silva
- Universidade Federal de Juiz de Fora (UFJF), Hospital Universitário, Juiz de Fora, Brasil
| | - Luiz Monte
- Universidade Federal de Juiz de Fora (UFJF), Hospital Universitário, Juiz de Fora, Brasil
| |
Collapse
|
20
|
What Is the Clinical Presentation of Adverse Local Tissue Reaction in Metal-on-metal Hip Arthroplasty? An MRI Study. Clin Orthop Relat Res 2019; 477:353-360. [PMID: 30794223 PMCID: PMC6370095 DOI: 10.1097/corr.0000000000000393] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Adverse local tissue reaction (ALTR) is not only a prominent cause of metal-on-metal (MoM) implant revision, but may also compromise the result of revision surgery. Patients treated with MoM arthroplasty and subsequently revised as a result of ALTR have been shown to experience worse patient-reported outcomes, inferior survivorship, and more complications when compared with patients receiving MoM implants who were revised for reasons other than ALTR. There is conflicting evidence as to whether the presence of symptoms is associated with ALTR in patients with MoM implants. Blood metal ions are associated with ALTR, but a consensus on appropriate thresholds associated with ALTR risk is lacking. QUESTIONS/PURPOSES (1) Was the presence of symptoms as measured by patient-reported outcome measures associated with ALTR presence and severity as noted on metal artifact reduction sequence (MARS)-MRI in patients treated with one design of MoM THA or hip resurfacing arthroplasty (HRA)? (2) Could reliable thresholds for blood metal ion levels be determined that were associated with ALTR presence on MARS-MRI? METHODS This retrospective study presents a secondary analysis of data drawn from a prospective, international, multicenter study of the recalled Articular Surface Replacement (ASR) hip system. This larger study aims to identify risk factors for revision and provide followup guidelines for the many unrevised ASR patients. A total of 1721 patients were enrolled from 16 centers in six countries after the device was recalled and are followed annually for 5 years. In the present analysis, data from the enrollment visit (mean time from index surgery, 7.5 years; SD 3.5 years) were considered. Only patients from two centers conducting MARS-MRI on all patients regardless of clinical presentation as a standard of care were included to avoid selection bias. A total of 327 unilateral patients fulfilled our inclusion criteria (90% of those eligible). The level of symptoms was systematically determined using the Harris hip score and a visual analog scale for pain, and whole blood metal ion levels were collected from all patients. MARS-MRIs were analyzed by a single reader for ALTR presence (Anderson classification), diameter, and synovial thickness. A validation series of 35 MARS-MRIs indicated excellent intrareader reproducibility of the evaluations (intraclass correlation = 0.82) and substantial agreement (κ coefficient = 0.64) was achieved between the MARS-MRI reader and a musculoskeletal radiologist with > 10 years of experience with MARS-MRI. Binary logistic regression was used to determine variables independently associated with ALTR. Receiver operator characteristic curves were used to determine sensitive and specific cut points for cobalt and chromium. RESULTS After controlling for confounding variables, presence of symptoms was determined to be a risk factor for ALTR (odds ratio, 2.9; p = 0.007) in patients treated with ASR MoM THA. Moreover, among patients undergoing ASR MoM THA with ALTR, synovial thickness correlated with symptomaticity (p = 0.030). For patients undergoing ASR MoM HRA, we found no association between symptoms and ALTR prevalence or severity. A cobalt cutoff of 3.2 parts per billion (ppb) was associated with increased risk of ALTR (p < 0.001; sensitivity, 68%; specificity, 71%) in ASR MoM THA. In patients with ASR MoM HRA, a cobalt threshold of 2.9 ppb was indicative of ALTR (p < 0.001; sensitivity, 79%; specificity, 69%). CONCLUSIONS The risk factors identified in the current study may be used to stratify patients receiving MoM implants in terms of ALTR risk. We found that symptoms are associated with an increased likelihood of ALTR presence in ASR MoM THA and that cobalt ion level is associated with ALTR in ASR MoM THA as well as ASR MoM HRA. Importantly, MoM HRA followup protocols that exempt asymptomatic patients from annual followup are not justified because asymptomatic patients are no less likely to have ALTR than symptomatic patients. Blood metal ion levels may reliably be used to screen patients undergoing MoM HRA. For patients undergoing MoM THA, a combination of symptom state and blood metal ion levels may be used to determine ALTR risk. LEVEL OF EVIDENCE Level III, diagnostic study.
Collapse
|
21
|
Hjorth MH, Mechlenburg I, Soballe K, Roemer L, Stilling M. The correlation between activity level, serum-ion concentrations and pseudotumours in patients with metal-on-metal hip articulations and metal-on-polyethylene total hip articulations. J Orthop Translat 2018; 18:74-83. [PMID: 31508310 PMCID: PMC6718878 DOI: 10.1016/j.jot.2018.11.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Revised: 11/09/2018] [Accepted: 11/19/2018] [Indexed: 12/22/2022] Open
Abstract
Purpose Young and physically active patients have mainly received metal-on-metal (MoM) total hip arthroplasty (THA) and resurfacing hip arthroplasty (RHA). However, the correlation between daily physical activity (PA) levels, serum-ion concentrations of chromium and cobalt and pseudotumours formation of patients who underwent MoM THA/RHA is insufficiently explored. Methods Ninety-nine patients with 134 hip articulations, 71 MoM THA/RHA and 63 MoP THA participated in a cross-sectional study at XXX University Hospital, Denmark, at mean 7.3 (range: 0.4–21.7) years after surgery. Patients' daily PA was monitored during a two-week period using a triaxial accelerometer. Metal artefact reduction sequence magnetic resonance imaging scans, estimation of serum-ion concentrations of chromium and cobalt and the Copenhagen Hip and Groin Outcome Score (HAGOS) questionnaire were completed on Day 14. Results Patients with a pseudotumour who underwent MoM THA/RHA had a higher average cadence of median 101.4 [interquartile range (IQR: 95.5–105)] steps/min than patients without a pseudotumor, median 96.7 (IQR: 92.2–103) steps/min (p = 0.02). Serum-ion concentrations of chromium and cobalt were higher in patients with a pseudotumour who underwent MoM THA/RHA, median 2.57 (IQR: 1.4–3.4) μg/L and 1.80 (IQR: 1.2–2.6) μg/L, respectively, than in patients without a pseudotumour, median 1.85 (IQR: 1.1–3.2) μg/L and 1.34 (IQR: 0.9–2.2) μg/L in MoM THA/RHA (p = 0.04 and p = 0.03). There was no statistical difference in these parameters between patients with and without a pseudotumour who underwent MoP THA. Daily PA levels of patients who underwent MoM THA/RHA were significantly correlated with serum-ion concentrations of chromium (p = 0.0002, r = 0.44) and cobalt (p = 0.005, r = 0.34), whereas no correlations were seen among patients who underwent MoP THA (p > 0.12). Conclusion The daily PA level of patients who underwent MoM THA/RHA influences the serum-ion concentrations of chromium and cobalt and the risk of pseudotumour formation. Translational potential of this article Results of this article add important knowledge on potential recommendations of prosthesis selection for patients with a high level of physical activity.
Collapse
Affiliation(s)
- Mette Holm Hjorth
- Department of Orthopaedics, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark.,Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200 Aarhus N, Denmark
| | - Inger Mechlenburg
- Department of Orthopaedics, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark.,Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200 Aarhus N, Denmark
| | - Kjeld Soballe
- Department of Orthopaedics, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark.,Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200 Aarhus N, Denmark
| | - Lone Roemer
- Department of Radiology, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark
| | - Maiken Stilling
- Department of Orthopaedics, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark.,Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200 Aarhus N, Denmark
| |
Collapse
|
22
|
Surgical Treatment of Intrapelvic Pseudotumour after Hip Resurfacing Arthroplasty: Case Report and Literature Review. Case Rep Orthop 2018; 2018:3808362. [PMID: 30498612 PMCID: PMC6222224 DOI: 10.1155/2018/3808362] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Revised: 08/08/2018] [Accepted: 08/15/2018] [Indexed: 12/12/2022] Open
Abstract
Hip replacement is the surgery of the last century due to its impact on the quality of life. A pseudotumour is a rare complication of hip arthroplasty, and it is related to a metal-bearing surface. Pseudotumour is a challenging scenario for hip surgeons due to poor clinical outcomes. The patient consulted for hip pain and paresthesia in the left lower extremity, and analyses showed that the cause was a sizeable intrapelvic pseudotumour. A multidisciplinary team surgery was planned. At first, an infraumbilical approach was made to resect the intrapelvic-retroperitoneum portion of the pseudotumour. Then, a posterolateral hip approach was performed, to resect the remaining portion of the pseudotumour and revision arthroplasty. At five years of follow-up, there are no clinical or imaging signs of recurrence of the pseudotumour. Treatment evidence is limited to a series of cases and expert opinions; we encourage complete resection and revision arthroplasty.
Collapse
|
23
|
Nyga A, Hart A, Tetley TD. Molecular analysis of HIF activation as a potential biomarker for adverse reaction to metal debris (ARMD) in tissue and blood samples. J Biomed Mater Res B Appl Biomater 2018; 107:1352-1362. [PMID: 30261121 DOI: 10.1002/jbm.b.34227] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2017] [Revised: 06/14/2018] [Accepted: 08/12/2018] [Indexed: 12/25/2022]
Abstract
We aimed to find a biomarker for patients with adverse reaction to metal debris (ARMD) due to a metal-on-metal (MoM) hip implant. First, we compared molecular markers of hypoxia-inducible factor (HIF) pathway activation (BNIP3, GLUT1, HO1, VEGF, and HIF1A) and inflammatory response (IL1B and COX2) in tissue from patients undergoing revision of MoM hip implant with tissue from patients undergoing primary hip replacement (PHR). Second, we compared blood levels of the above molecular markers and additional inflammatory markers: TNFA, IL18, CASPASE1, NFKB or IKB, and TLR1-4 mRNA in patients with non-failed MoM hips. We report the presence of increased expression of HIF-target genes in the periprosthetic tissue in MoM patients when compared to the PHR group. This suggests HIF pathway activation due to MoM debris and the potential of using HIF targets as a predictor of failure. Analysis of blood samples from nonoverlapping, nonfailed, MoM group showed significantly higher expression of COX2 mRNA and significant correlations between HIF1A and GLUT1 mRNA expressions, and between HIF1A mRNA and selection of inflammatory genes, including IL18, IKB, TLR1, and TLR4. HIF pathway activation in the periprosthetic tissue biopsies of patients with hip replacements may represent the first biomarker to identify early ARMD. Further studies investigating blood biomarkers could also prove beneficial in detecting ARMD that could lead to an early intervention and improved patient outcome after hip revision surgery. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1352-1362, 2019.
Collapse
Affiliation(s)
- Agata Nyga
- Department of Pharmacology and Toxicology, National Heart & Lung Institute, Imperial College London, London, UK
| | - Alister Hart
- Institute of Orthopaedics & Musculoskeletal Science, Royal National Orthopaedic Hospital, University College London, Stanmore, UK
| | - Teresa D Tetley
- Department of Pharmacology and Toxicology, National Heart & Lung Institute, Imperial College London, London, UK
| |
Collapse
|
24
|
Hjorth MH, Mechlenburg I, Soballe K, Jakobsen SS, Roemer L, Stilling M. Physical Activity Is Associated With the Level of Chromium but Not With Changes in Pseudotumor Size in Patients With Metal-on-Metal Hip Arthroplasty. J Arthroplasty 2018; 33:2932-2939. [PMID: 29807790 DOI: 10.1016/j.arth.2018.04.039] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2018] [Revised: 04/17/2018] [Accepted: 04/23/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Metal-on-metal (MoM) total hip arthroplasty (THA) and resurfacing hip arthroplasty (RHA) were previously considered an excellent option for young and physically active patients. However, the relationship between MoM THA/RHA patients' daily physical activity (PA), metal ion measurements of chromium and cobalt, and pseudotumor dynamic is insufficiently explored. METHODS One hundred eleven patients with 148 hip articulations, 77 MoM THA/RHA and 71 MoP THA, participated in a prospective cohort study, with 5 cross-sectional analyses during a 1-year follow-up. Baseline follow-up was at mean 7.1 (range: 0.2-21.5) years postoperative. At baseline and every 3 months thereafter, patients' daily PA was monitored during a 2-week period using a triaxial accelerometer, and next metal artifact reducing sequence magnetic resonance imaging scans, metal ion measurements of chromium and cobalt, and the Copenhagen Hip and Groin Outcome Score questionnaire were completed. RESULTS We found a statistically significant relationship between daily PA and metal ion measurements of chromium at all follow-ups in MoM THA/RHA patients (P ≤ .03) but not in MoP THA patients (P > .35). Patients' daily PA was not related to changes in pseudotumor size at any follow-up (P > .30). Ten of 26 (38%) pseudotumors in MoM THA/RHA and 8 of 29 (28%) pseudotumors in MoP THA changed classification according to the Anderson grading. No pseudotumors transformed in appearance or changed anatomical location. CONCLUSION The daily PA of MoM THA/RHA patients is associated with metal ion measurements of chromium but not with changes in pseudotumor size. This is new and important knowledge, which may be useful for hip surgeons in recommendation and monitoration of the consequences of PA in active patients with MoM THA/RHA.
Collapse
Affiliation(s)
- Mette H Hjorth
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Inger Mechlenburg
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Kjeld Soballe
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Stig S Jakobsen
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Lone Roemer
- Department of Radiology, Aarhus University Hospital, Aarhus, Denmark
| | - Maiken Stilling
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| |
Collapse
|
25
|
Connelly JW, Galea VP, Laaksonen I, Matuszak SJ, Madanat R, Muratoglu O, Malchau H. Indications for MARS-MRI in Patients Treated With Articular Surface Replacement XL Total Hip Arthroplasty. J Arthroplasty 2018; 33:2906-2911. [PMID: 29776852 DOI: 10.1016/j.arth.2018.04.021] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Revised: 04/09/2018] [Accepted: 04/09/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The purpose of this study was to identify which patient and clinical factors are predictive of adverse local tissue reaction (ALTR) and to use these factors to create a highly sensitive algorithm for indicating metal artifact reduction sequence magnetic resonance imaging (MARS-MRI) in Articular Surface Replacement (ASR) XL total hip arthroplasty patients. Our secondary aim was to compare our algorithm to existing national guidelines on when to take MARS-MRI in metal-on-metal total hip arthroplasty patients. METHODS The study consisted of 137 patients treated with unilateral ASR XL implants from a prospective, multicenter study. Patients underwent MARS-MRI regardless of clinical presentation at a mean of 6.2 (range, 3.3-10.4) years from surgery. Univariate and multivariate analyses were conducted to determine which variables were predictive of ALTR. Predictors were used to create an algorithm to indicate MARS-MRI. Finally, we compared our algorithm's ability to detect ALTR to existing guidelines. RESULTS We found a visual analog scale pain score ≥2 (odds ratio [OR] = 2.53; P = .023), high blood cobalt (OR = 1.05; P = .023), and male gender (OR = 2.37; P = .034) to be significant predictors of ALTR presence in our cohort. The resultant algorithm achieved 86.4% sensitivity and 60.2% specificity in detecting ALTR within our cohort. Our algorithm had the highest area under the curve and was the only guideline that was significantly predictive of ALTR (P = .014). CONCLUSION Our algorithm including patient-reported pain and sex-specific cutoffs for blood cobalt levels could predict ALTR and indicate MARS-MRI in our cohort of ASR XL metal-on-metal patients with high sensitivity. LEVEL OF EVIDENCE Level II, diagnostic study.
Collapse
Affiliation(s)
- James W Connelly
- Harris Orthopaedic Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts
| | - Vincent P Galea
- Harris Orthopaedic Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts
| | - Inari Laaksonen
- Harris Orthopaedic Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopaedic Surgery, Harvard Medical School, Boston, Massachusetts
| | - Sean J Matuszak
- Harris Orthopaedic Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts
| | - Rami Madanat
- Harris Orthopaedic Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopaedic Surgery, Harvard Medical School, Boston, Massachusetts; Department of Orthopaedics and Traumatology, Helsinki University Hospital, Helsinki, Finland
| | - Orhun Muratoglu
- Harris Orthopaedic Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopaedic Surgery, Harvard Medical School, Boston, Massachusetts
| | - Henrik Malchau
- Harris Orthopaedic Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopaedic Surgery, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
26
|
Higher Prevalence of Mixed or Solid Pseudotumors in Metal-on-Polyethylene Total Hip Arthroplasty Compared With Metal-on-Metal Total Hip Arthroplasty and Resurfacing Hip Arthroplasty. J Arthroplasty 2018. [PMID: 29526334 DOI: 10.1016/j.arth.2018.02.011] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Pseudotumors are a common finding in metal-on-metal (MoM) total hip arthroplasty (THA) and resurfacing hip arthroplasty (RHA). However, information on pseudotumors in metal-on-polyethylene (MoP) THA is limited. METHODS One hundred eleven patients with 148 hip articulations-30 MoM THA, 47 MoM RHA, and 71 MoP THA-participated in a cross-sectional study at mean 7.1 (range: 0.2-21.5) years postoperatively. Patients were evaluated with metal artifact reducing sequence magnetic resonance imaging, measurements of metal ions, clinical scores of Harris Hip Score, Oxford Hip Score, the Copenhagen Hip and Groin Outcome Score, and conventional radiographs. RESULTS Pseudotumors were present in 13 of 30 (43%) MoM THA, 13 of 47 (28%) MoM RHA, and 29 of 71 (41%) MoP THA patients, which was a similar prevalence (P = .10). The prevalence of mixed or solid pseudotumors was significantly higher in patients with MoP THA (n = 10) compared to MoM THA (n = 3) and MoM THA (n = 0), (P = .01). Hips with a mixed or solid pseudotumor had significantly poorer scores of Harris Hip Score (P = .01) and OHS (P = .002) and higher metal ion levels of cobalt (P = .0009) compared to hips without a pseudotumor or with a cystic pseudotumor. CONCLUSION Pseudotumors have primarily been associated with MoM hip articulations, but we found a similar pseudotumor prevalence in MoP THA, which is the most common bearing worldwide. Mixed or solid pseudotumors were more often seen in MoP THA compared with MoM hip articulations, and patients with a mixed or solid pseudotumor had poorer clinical scores and higher metal ion levels than patients without a pseudotumor or with a cystic pseudotumor.
Collapse
|
27
|
Persson A, Eisler T, Bodén H, Krupic F, Sköldenberg O, Muren O. Revision for Symptomatic Pseudotumor After Primary Metal-on-Polyethylene Total Hip Arthroplasty with a Standard Femoral Stem. J Bone Joint Surg Am 2018; 100:942-949. [PMID: 29870445 DOI: 10.2106/jbjs.17.00616] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Pseudotumor formation following total hip arthroplasty (THA) is a well-known complication mainly associated with metal-on-metal (MoM) bearings and taper corrosion on modular-neck femoral stems. The purpose of this study was to determine the prevalence of revision surgery for symptomatic pseudotumors in a large cohort of patients treated with primary THA with a standard stem and a non-MoM articulation. METHODS We included 2,102 patients treated with a total of 2,446 THAs from 1999 until May 2016 in a prospective, observational cohort study. All patients underwent THA with the same uncemented, non-modular-neck femoral stem and metal-on-polyethylene (MoP) (n = 2,409) or ceramic-on-polyethylene (n = 37) articulation. All patients were followed by means of a combination of surgical and medical chart review, follow-up visits, and the Swedish Hip Arthroplasty Register. Metal artifact reduction sequence magnetic resonance imaging (MARS MRI) was used for diagnosis of the pseudotumors, and serum metal ion levels and inflammatory marker levels were measured for all patients who underwent a revision due to pseudotumor. RESULTS The prevalence of revision for symptomatic pseudotumor formation was 0.5% (13 cases) at a mean follow-up time of 7 years. The incidence rate was 0.9 case per 1,000 person-years. All 13 revisions were done in patients with an MoP articulation. CONCLUSIONS This study demonstrated a 0.5% prevalence of revision due to symptomatic pseudotumor formation in a cohort of patients who underwent THA with a non-MoM construct. Surgeons should be aware that symptomatic pseudotumor formation requiring revision surgery is a tangible complication even after standard MoP THA. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Anders Persson
- Department of Orthopaedics, Danderyd University Hospital, Karolinska Institute at Danderyd University Hospital, Stockholm, Sweden
| | - Thomas Eisler
- Department of Orthopaedics, Danderyd University Hospital, Karolinska Institute at Danderyd University Hospital, Stockholm, Sweden
| | - Henrik Bodén
- Department of Orthopaedics, Danderyd University Hospital, Karolinska Institute at Danderyd University Hospital, Stockholm, Sweden
| | - Ferid Krupic
- Department of Orthopaedics and Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Olof Sköldenberg
- Department of Orthopaedics, Danderyd University Hospital, Karolinska Institute at Danderyd University Hospital, Stockholm, Sweden
| | - Olav Muren
- Department of Orthopaedics, Danderyd University Hospital, Karolinska Institute at Danderyd University Hospital, Stockholm, Sweden
| |
Collapse
|
28
|
Pinter ZW, Smith KS, Hudson PW, Jones CW, Hadden R, Elattar O, Shah A. A Retrospective Case Series of Carbon Fiber Plate Fixation of Ankle Fractures. Foot Ankle Spec 2018; 11:223-229. [PMID: 28677405 DOI: 10.1177/1938640017718343] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
UNLABELLED Distal fibula fractures represent a common problem in orthopaedics. When fibula fractures require operative fixation, implants are typically made from stainless steel or titanium alloys. Carbon fiber implants have been used elsewhere in orthopaedics for years, and their advantages include a modulus of elasticity similar to that of bone, biocompatibility, increased fatigue strength, and radiolucency. This study hypothesized that carbon fiber plates would provide similar outcomes for ankle fracture fixation as titanium and steel implants. A retrospective chart review was performed of 30 patients who underwent fibular open reduction and internal fixation (ORIF). The main outcomes assessed were postoperative union rate and complication rate. The nonunion or failure rate for carbon fiber plates was 4% (1/24), and the union rate was 96% (23/24). The mean follow-up time was 20 months, and the complication rate was 8% (2/24). Carbon fiber plates are a viable alternative to metal plates in ankle fracture fixation, demonstrating union and complication rates comparable to those of traditional fixation techniques. Their theoretical advantages and similar cost make them an attractive implant choice for ORIF of the fibula. However, further studies are needed for extended follow-up and inclusion of larger patient cohorts. LEVELS OF EVIDENCE Level IV: Retrospective Case series.
Collapse
Affiliation(s)
| | | | - Parke W Hudson
- University of Alabama at Birmingham, Birmingham, Alabama
| | - Caleb W Jones
- University of Alabama at Birmingham, Birmingham, Alabama
| | - Ryan Hadden
- University of Alabama at Birmingham, Birmingham, Alabama
| | - Osama Elattar
- University of Alabama at Birmingham, Birmingham, Alabama
| | - Ashish Shah
- University of Alabama at Birmingham, Birmingham, Alabama
| |
Collapse
|
29
|
Long-term clinical results of the Metasul metal-on-metal total hip arthroplasty: 12.6 years follow-up of 128 primary total hip replacements. Hip Int 2018; 28:330-335. [PMID: 29048689 DOI: 10.5301/hipint.5000574] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION The purpose of the present study is to report the long-term clinical results of an uncemented total hip arthroplasty (THA) using a Metasul metal-on-metal (MoM) 28-mm bearing and to evaluate the long-term serum cobalt levels. METHODS At an average of 12.6 years following primary THA, we retrospectively reviewed the clinical results of the first 116 consecutive patients (128 THAs) in our institution who underwent 28-mm Metasul MoM THA. Of the 78 patients who were able to visit our outpatient clinic, serum cobalt levels were evaluated. RESULTS The overall survival rate of the cohort was 96.1% (95% confidence interval [CI], 93.2-99.6), 12.6 years (95% CI, 12.3-12.7 years) following surgery. 3 patients had undergone revision due to aseptic loosening of the stem and 2 patients sustained a periprosthetic fracture. The average modified Harris Hip Score was 90 (72-97) and the average Oxford Hip Score was 56 (48-60), representing both excellent outcome scores. The average serum cobalt of the entire cohort was 20.1 nmol/L (range 8.5-227.7 nmol/L). Serum cobalt levels of patients with a bilateral MoM THA were significantly higher (35.0 nmol/l, p<0.01). No relation between serum cobalt levels, subjective outcome, radiolucent lines on radiographs and survivorship of the implant was noted. CONCLUSIONS Long-term results of the metasul MoM bearing articulation in THA seem to be excellent, although cobalt serum levels should be monitored closely.
Collapse
|
30
|
Bijukumar DR, Segu A, Souza JCM, Li X, Barba M, Mercuri LG, J Jacobs J, Mathew MT. Systemic and local toxicity of metal debris released from hip prostheses: A review of experimental approaches. NANOMEDICINE : NANOTECHNOLOGY, BIOLOGY, AND MEDICINE 2018; 14:951-963. [PMID: 29339190 PMCID: PMC6017990 DOI: 10.1016/j.nano.2018.01.001] [Citation(s) in RCA: 69] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Revised: 12/22/2017] [Accepted: 01/02/2018] [Indexed: 12/12/2022]
Abstract
Despite the technological improvements in orthopedic joint replacement implants, wear and corrosion products associated with the metal components of these implants may result in adverse local tissue and perhaps systemic reactions and toxicities. The current review encompasses a literature review of the local and systemic toxicity studies concerning the effect of CoCrMo wear debris released from wear and corrosion of orthopedic implants and prostheses. Release of metallic debris is mainly in the form of micro- and nano-particles, ions of different valences, and oxides composed of Co and Cr. Though these substances alter human biology, their direct effects of these substances on specific tissue types remain poorly understood. This may partially be the consequence of the multivariate research methodologies employed, leading to inconsistent reports. This review proposes the importance of developing new and more appropriate in-vitro methodologies to study the cellular responses and toxicity mediated by joint replacement wear debris in-vivo.
Collapse
Affiliation(s)
- Divya Rani Bijukumar
- Regenerative Medicine and Disability Research Lab, Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, IL, USA
| | - Abhijith Segu
- Regenerative Medicine and Disability Research Lab, Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, IL, USA
| | - Júlio C M Souza
- Center for MicroElectromechanical Systems (CMEMS-UMINHO), University of Minho, Guimaraes, Portugal
| | - XueJun Li
- Regenerative Medicine and Disability Research Lab, Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, IL, USA
| | - Mark Barba
- Regenerative Medicine and Disability Research Lab, Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, IL, USA; OrthoIllinois, Rockford, IL, USA
| | - Louis G Mercuri
- Department of Orthopedics, Rush University Medical Center, Chicago, IL, USA
| | - Joshua J Jacobs
- Department of Orthopedics, Rush University Medical Center, Chicago, IL, USA
| | - Mathew Thoppil Mathew
- Regenerative Medicine and Disability Research Lab, Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, IL, USA; Department of Orthopedics, Rush University Medical Center, Chicago, IL, USA; Department of Bioengineering, University of Illinois at Chicago, IL, USA.
| |
Collapse
|
31
|
Goodnough LH, Bala A, Huddleston J, Goodman SB, Maloney WJ, Amanatullah DF. Metal-on-metal total hip arthroplasty is not associated with cardiac disease. Bone Joint J 2018; 100-B:28-32. [PMID: 29305447 DOI: 10.1302/0301-620x.100b1.bjj-2017-0366.r1] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS Many case reports and small studies have suggested that cobalt ions are a potential cause of cardiac complications, specifically cardiomyopathy, after metal-on-metal (MoM) total hip arthroplasty (THA). The impact of metal ions on the incidence of cardiac disease after MoM THA has not been evaluated in large studies. The aim of this study was to compare the rate of onset of new cardiac symptoms in patients who have undergone MoM THA with those who have undergone metal-on-polyethylene (MoP) THA. PATIENTS AND METHODS Data were extracted from the Standard Analytics Files database for patients who underwent MoM THA between 2005 and 2012. Bearing surface was selected using International Classification of Diseases ninth revision codes. Patients with a minimum five-year follow-up were selected. An age and gender-matched cohort of patients who underwent MoP THA served as a comparison group. New diagnoses of cardiac disease were collected during the follow-up period. Comorbidities and demographics were identified and routine descriptive statistics were used. RESULTS We identified 29 483 patients who underwent MoM THA and 24 175 matched patients who underwent MoP THA. Both groups had a mean Charlson comorbidity index score of 4. There were no statistically significant differences in 30 of 31 pre-existing comorbidities. Patients undergoing MoM THA had a slightly lower incidence of cardiac failure compared with those undergoing MoP THA at three years (6.60% versus 7.06%, odds ratio (OR) 0.93, 95% confidence interval (CI) 0.87 to 0.99) and four years (8.73% versus 9.49%, OR 0.91, 95% CI 0.86 to 0.97) postoperatively, with no difference in the incidence of new cardiac failure in between the groups at five years. There was no statistically significant difference in the incidence of arrhythmia, myocardial infarction and cardiomyopathy at any time between the two groups. CONCLUSION MoM THA is not associated with cardiac complications. Initial reports may have represented individual instances of cardiac disease in patients with a failing MoM articulation rather than an emerging epidemiological trend. Cite this article: Bone Joint J 2018;100-B:28-32.
Collapse
Affiliation(s)
- L H Goodnough
- Stanford University, 450 Broadway Street, Redwood City, California, 94063, USA
| | - A Bala
- Stanford University, 450 Broadway Street, Redwood City, California, 94063, USA
| | - J Huddleston
- Stanford University, 450 Broadway Street, Redwood City, California, 94063, USA
| | - S B Goodman
- Stanford University, 450 Broadway Street, Redwood City, California, 94063, USA
| | - W J Maloney
- Stanford University, 450 Broadway Street, Redwood City, California, 94063, USA
| | - D F Amanatullah
- Stanford University, 450 Broadway Street, Redwood City, California, 94063, USA
| |
Collapse
|
32
|
Pseudotumor in metal-on-metal hip arthroplasty: a comparison study of three grading systems with MRI. Skeletal Radiol 2018; 47:1099-1109. [PMID: 29388037 PMCID: PMC6003970 DOI: 10.1007/s00256-018-2873-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2017] [Revised: 12/09/2017] [Accepted: 01/02/2018] [Indexed: 02/08/2023]
Abstract
OBJECTIVE Pseudotumors, a well-known complication of metal-on-metal total hip arthroplasty (MoM THA), are well identified on metal artifact-reducing sequences magnetic resonance imaging (MARS-MRI). Several MRI grading systems are described in the orthopedic literature, but their validity is unknown in large clinical studies. Our study was undertaken to describe the classification of pseudotumors in a preselected cohort divided into high- and low-risk patients, using three pseudotumor grading systems applied on MARS-MRI, and to determine the interobserver reliability of the grading systems. PATIENTS AND METHODS A retrospective study was performed on 377 consecutive patients (240 MRI scans) treated with an M2a-38 and Taperloc stem combination (Biomet, Warsaw, IN, USA). Patients were divided into a high-risk and a low-risk group based on previous published risk factors. Two observers determined the presence of pseudotumors using three different pseudotumor grading systems for classifying MARS-MRI results. RESULTS The prevalence of pseudotumors as determined with MARS-MRI was 59% in our high-risk group, 0% in the low-risk group and 43% in the control group. Serum cobalt values were increased in the high-risk group. The kappa values of the Anderson, Hauptfleisch and Matthies grading system scores were 0.43, 0.44, and 0.49 respectively. CONCLUSIONS High-risk patients are at a high risk for pseudotumor development. No pseudotumor development was found in low-risk patients. Interobserver reliability scored best with the Matthies system, but all three grading systems showed only a moderate agreement.
Collapse
|
33
|
Granchi D, Savarino LM, Ciapetti G, Baldini N. Biological effects of metal degradation in hip arthroplasties. Crit Rev Toxicol 2017; 48:170-193. [PMID: 29130357 DOI: 10.1080/10408444.2017.1392927] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Metals and metal alloys are the most used materials in orthopedic implants. The focus is on total hip arthroplasty (THA) that, though well tolerated, may be associated with local and remote adverse effects in the medium-long term. This review aims to summarize data on the biological consequences of the metal implant degradation that have been attributed predominantly to metal-on-metal (MoM) THA. Local responses to metals consist of a broad clinical spectrum ranging from small asymptomatic tissue lesions to severe destruction of bone and soft tissues, which are designated as metallosis, adverse reactions to metal debris (ARMD), aseptic lymphocytic vasculitis associated lesion (ALVAL), and pseudotumors. In addition, the dissemination of metal particles and ions throughout the body has been associated with systemic adverse effects, including organ toxicity, cancerogenesis, teratogenicity, and immunotoxicity. As proved by the multitude of studies in this field, metal degradation may increase safety issues associated with THA, especially with MoM hip systems. Data collection regarding local, systemic and long-term effects plays an essential role to better define any safety risks and to generate scientifically based recommendations.
Collapse
Affiliation(s)
- Donatella Granchi
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Lucia Maria Savarino
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Gabriela Ciapetti
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Nicola Baldini
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy.,b Department of Biomedical and Neuromotor Science , University of Bologna , Bologna , Italy
| |
Collapse
|
34
|
Fernández-Caso B, Domingo García D, Domingo LC, Ampuero JC. Ruminococcus gnavus infection of a metal-on-metal hip arthroplasty resembling a pseudo-tumour in a 72 year-old woman with no intestinal symptoms. Enferm Infecc Microbiol Clin 2017; 35:542-543. [DOI: 10.1016/j.eimc.2016.11.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2016] [Revised: 10/28/2016] [Accepted: 11/01/2016] [Indexed: 11/30/2022]
|
35
|
Mäntymäki H, Junnila M, Lankinen P, Seppänen M, Vahlberg T, Mäkelä KT. Systematic Screening of Adverse Reactions to Metal Debris after Recap-M2A-Magnum Metal-on-Metal Total Hip Arthroplasty. Scand J Surg 2017; 106:342-349. [DOI: 10.1177/1457496916683093] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Background and Aims: An adverse reaction to metal debris is a known complication after large diameter head metal-on-metal total hip arthroplasty. However, the failure rate varies depending on the implant design. Therefore, we investigated the prevalence of adverse reaction to metal debris, as well as the symptoms and risk factors after undergoing a ReCap-M2a-Magnum large diameter head metal-on-metal total hip arthroplasty. Materials and Methods: Between 2005 and 2012, 1188 patients (1329 hips) underwent ReCap-M2a-Magnum total hip arthroplasty at our institution. Systematic screening for adverse reaction to metal debris was arranged using the Oxford Hip Score questionnaire, hip and pelvic radiographs, and assessments of the serum chromium and cobalt ion levels. Clinical evaluation and magnetic resonance imaging were performed for the symptomatic patients, as well as those with either chromium or cobalt ion levels ⩾5 µg/L. The prevalence of adverse reaction to metal debris after ReCap-M2a-Magnum total hip arthroplasty was assessed, and the risk factors for adverse reaction to metal debris were evaluated using logistic regression. The mean follow-up time was 5.2 (0.003–9.1) years. This study was an extension of a previous study conducted at our institution with 80 patients. Results: In total, 33 patients (33 hips, 2.5% of all hips) required a revision operation due to adverse reaction to metal debris. Moreover, 157 hips exhibited definitive adverse reaction to metal debris, but a revision operation was not performed (157 of 1329 hips, 11.8% of all hips). Overall, 190 out of 1329 (14.3%) hips had definitive adverse reaction to metal debris. Pain, subluxation sensation, clicking, swelling, a small head size, and a fair/poor Oxford Hip Score were associated with definitive adverse reaction to metal debris. Conclusion: We found a high prevalence of adverse reaction to metal debris in the ReCap-M2a-Magnum total hip arthroplasty patients in this study; however, most of the patients did not require revision operations.
Collapse
Affiliation(s)
- H. Mäntymäki
- Department of Orthopaedics and Traumatology, Turku University Hospital, Turku, Finland
- Department of Surgery, Vaasa Central Hospital, Vaasa, Finland
| | - M. Junnila
- Department of Orthopaedics and Traumatology, Turku University Hospital, Turku, Finland
| | - P. Lankinen
- Department of Orthopaedics and Traumatology, Turku University Hospital, Turku, Finland
| | - M. Seppänen
- Department of Orthopaedics and Traumatology, Turku University Hospital, Turku, Finland
| | - T. Vahlberg
- Department of Biostatistics, University of Turku, Turku, Finland
| | - K. T. Mäkelä
- Department of Orthopaedics and Traumatology, Turku University Hospital, Turku, Finland
| |
Collapse
|
36
|
Li J, Zhou K, Chen Z, Wang D, Zhou Z, Kang P, Shen B, Yang J, Pei F. [Mid- and long-term effectiveness and failure causes analysis of large-head metal-on-metal total hip arthroplasty]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2017; 31:144-149. [PMID: 29786243 PMCID: PMC8458156 DOI: 10.7507/1002-1892.201605122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Revised: 01/05/2017] [Indexed: 02/05/2023]
Abstract
Objective To explore the effectiveness and failure causes of large-head metal-on-metal total hip arthroplasty (large-head MoM THA). Methods Between March 2007 and May 2010, 159 patients (183 hips) underwent large-head MoM THA, and the clinical data were analyzed. There were 50 females (54 hips) and 109 males (129 hips) with an average age of 50 years (range, 20-78 years). Single hip was involved in 135 cases (left hip in 69 cases and right hip in 66 cases) and double hips in 24 cases. The causes included femoral head necrosis in 74 cases (93 hips), Legg-Calve-Perthes in 1 case (1 hip), osteoarthritis in 18 cases (19 hips), developmental dysplasia of the hip in 17 cases (18 hips), osteoarthritis after hip septic infection in 8 cases (8 hips), traumatic arthritis of the hip in 6 cases (6 hips), femoral neck fracture in 17 cases (17 hips), ankylosing spondylitis in 8 cases (11 hips), rheumatoid arthritis of hip in 9 cases (9 hips), and adult onset Still's disease in 1 case (1 hip). Before operation, visual analogue scale (VAS) was 6.59±0.87; Harris score was 45.99±8.07. Results Healing of incisions by first intention was achieved, and no operative complication occurred. The patients were followed up 1.2-8.2 years (mean, 6.1 years). Implant failure was observed in 15 cases (17 hips), and the 5-year survival rate of large-head MoM THA was 91.80% (168/183). The causes of implant failure after THA were inflammatory pseudotumor in 4 cases (4 hips), acetabular aseptic loosening in 3 cases (3 hips), osteolysis in 4 cases (5 hips), acetabular aseptic loosening combined with inflammatory pseudotumor in 3 cases (3 hips), and functional disused in 1 case (2 hips). Of them, 9 cases (11 hips) did not receive revision surgery for various reasons, while 6 cases (6 hips) underwent revision surgery at 1.2-5.4 years (mean 3.7 years) after large-head MoM THA. At last follow-up, VAS and Harris score were 1.72±1.48 and 81.37±10.75 respectively, showing significant differences when compared with preoperative scores ( t=-35.547, P=0.000; t=33.823, P=0.000). The function was excellent in 44 hips, good in 89 hips, fair in 33 hips, and poor in 17 hips. Conclusion Large-head MoM THA has a high revision rate during mid- and long-term follow-up because of inflammatory pseudotumor, acetabular aseptic loosening, and osteolysis. Early revision can effectively improve the function of the hip and improve patients'quality of life.
Collapse
Affiliation(s)
- Jinlong Li
- Department of Orthopedics, West China Hospital, Sichuan University, Chengdu Sichuan, 610041, P.R.China
| | - Kai Zhou
- Department of Orthopedics, West China Hospital, Sichuan University, Chengdu Sichuan, 610041, P.R.China
| | - Zhi Chen
- Department of Orthopedics, West China Hospital, Sichuan University, Chengdu Sichuan, 610041, P.R.China
| | - Duan Wang
- Department of Orthopedics, West China Hospital, Sichuan University, Chengdu Sichuan, 610041, P.R.China
| | - Zongke Zhou
- Department of Orthopedics, West China Hospital, Sichuan University, Chengdu Sichuan, 610041,
| | - Pengde Kang
- Department of Orthopedics, West China Hospital, Sichuan University, Chengdu Sichuan, 610041, P.R.China
| | - Bin Shen
- Department of Orthopedics, West China Hospital, Sichuan University, Chengdu Sichuan, 610041, P.R.China
| | - Jing Yang
- Department of Orthopedics, West China Hospital, Sichuan University, Chengdu Sichuan, 610041, P.R.China
| | - Fuxing Pei
- Department of Orthopedics, West China Hospital, Sichuan University, Chengdu Sichuan, 610041, P.R.China
| |
Collapse
|
37
|
Computed Tomography Imaging of a Hip Prosthesis Using Iterative Model-Based Reconstruction and Orthopaedic Metal Artefact Reduction: A Quantitative Analysis. J Comput Assist Tomogr 2017; 40:971-978. [PMID: 27331924 DOI: 10.1097/rct.0000000000000449] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To quantify the combined use of iterative model-based reconstruction (IMR) and orthopaedic metal artefact reduction (O-MAR) in reducing metal artefacts and improving image quality in a total hip arthroplasty phantom. METHODS Scans acquired at several dose levels and kVps were reconstructed with filtered back-projection (FBP), iterative reconstruction (iDose) and IMR, with and without O-MAR. Computed tomography (CT) numbers, noise levels, signal-to-noise-ratios and contrast-to-noise-ratios were analysed. RESULTS Iterative model-based reconstruction results in overall improved image quality compared to iDose and FBP (P < 0.001). Orthopaedic metal artefact reduction is most effective in reducing severe metal artefacts improving CT number accuracy by 50%, 60%, and 63% (P < 0.05) and reducing noise by 1%, 62%, and 85% (P < 0.001) whereas improving signal-to-noise-ratios by 27%, 47%, and 46% (P < 0.001) and contrast-to-noise-ratios by 16%, 25%, and 19% (P < 0.001) with FBP, iDose, and IMR, respectively. CONCLUSIONS The combined use of IMR and O-MAR strongly improves overall image quality and strongly reduces metal artefacts in the CT imaging of a total hip arthroplasty phantom.
Collapse
|
38
|
Do cobalt and chromium levels predict osteolysis in metal-on-metal total hip arthroplasty? Arch Orthop Trauma Surg 2016; 136:1657-1662. [PMID: 27631309 DOI: 10.1007/s00402-016-2565-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2015] [Indexed: 02/09/2023]
Abstract
INTRODUCTION Serum metal ions are part of the regular follow-up routine of patients with metal-on-metal total hip arthroplasties (MoM-THA). Increased cobalt levels have been suggested to indicate implant failure and corrosion. QUESTIONS (1) Is there a correlation between the size of the osteolysis measured on a CT scan and metal ion levels? (2) Can metal ion levels predict the presence of osteolysis in MoM-THA? (3) Are cobalt and chromium serum levels or the cobalt-chromium-ratio diagnostic for osteolysis? MATERIALS AND METHODS CT scans of patients (n = 75) with a unilateral MoM-THA (Birmingham Hip System, Smith & Nephew, TN, USA) implanted by a single surgeon were reviewed to determine the presence of osteolysis. Statistical analysis was performed to detect its association with metal ion levels at the time of the imaging exam. RESULTS The incidence of osteolysis was the same in men and women (35.6 vs 35.7 %). The cobalt-chromium-ratio correlates with the size of the osteolysis on the CT scan and the femoral component size in the overall study population (p = 0.050, p = 0.001) and in men (p = 0.002, p = 0.001) but not in women (p = 0.312, p = 0.344). The AUC for the cobalt-chromium-ratio to detect osteolysis was 0.613 (p = 0.112) for the overall population, 0.710 for men (p = 0.021) and 0.453 (p = 0.684) for women. The data suggest that a cut off level of 1.71 for the cobalt-chromium-ratio has a sensitivity of 62.5 % and specificity of 72.4 % to identify male patients with osteolysis. CONCLUSIONS The disproportional increase of cobalt over chromium, especially in male patients with large component sizes can not be explained by wear alone and suggests that other processes (corrosion) might contribute to metal ion levels and might be more pronounced in patients with larger component sizes.
Collapse
|
39
|
Lee YK, Yoon BH, Choi YS, Jo WL, Ha YC, Koo KH. Metal on Metal or Ceramic on Ceramic for Cementless Total Hip Arthroplasty: A Meta-Analysis. J Arthroplasty 2016; 31:2637-2645.e1. [PMID: 27215192 DOI: 10.1016/j.arth.2016.04.014] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2016] [Revised: 04/19/2016] [Accepted: 04/19/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Hard bearings, metal on metal (MOM) and ceramic on ceramic (COC), have been developed to overcome polyethylene wear-related osteolysis, but comparisons between these 2 hard bearings are limited. We performed a meta-analysis to determine revision rates for (1) any reason, (2) aseptic loosening, (3) periprosthetic joint infection (PJI), and (4) recurrent dislocation between MOM and COC bearings in cementless total hip arthroplasty. METHODS This analysis included 3 studies comparing COC and MOM bearings and 56 studies reporting outcomes of MOM or COC bearings. We conducted a comparison meta-analysis (with a fixed-effects model) on the 3 comparative studies and a proportional meta-analysis on the data from the 59 articles to determine a consensus. RESULTS In the comparison meta-analysis, MOM showed higher revision rate than COC for any reason (odds ratio = 2.39, P = .046) and PJI (odds ratio = 6.21, P = .015). In the proportion meta-analysis, the MOM group showed significantly higher revision rate than COC group for any reason, aseptic loosening, and PJI. CONCLUSION MOM bearings were associated with a higher risk of revision for any reason and PJI than COC bearings after cementless total hip arthroplasty.
Collapse
Affiliation(s)
- Young-Kyun Lee
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Byung-Ho Yoon
- Department of Orthopaedic Surgery, Inje University College of Medicine, Seoul Paik Hospital, Seoul, Korea
| | - Yun Seong Choi
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Woo-Lam Jo
- Department of Orthopaedic Surgery, The Catholic University of Seoul St. Mary's Hospital, Seoul, Korea
| | - Yong-Chan Ha
- Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea
| | - Kyung-Hoi Koo
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
| |
Collapse
|
40
|
A Comparison of Blood Metal Ions in Total Hip Arthroplasty Using Metal and Ceramic Heads. J Arthroplasty 2016; 31:2215-20. [PMID: 27108055 DOI: 10.1016/j.arth.2016.03.024] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2015] [Revised: 02/29/2016] [Accepted: 03/11/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND In recent time, metal ion debris and adverse local tissue reaction have reemerged as an area of clinical concern with the use of large femoral heads after total hip arthroplasty (THA). METHODS Between June 2014 and January 2015, 60 patients with a noncemented THA using a titanium (titanium, molybdenum, zirconium, and iron alloy) femoral stem and a V40 trunnion were identified with a minimum 5-year follow-up. All THAs had a 32- or 36-mm metal (n = 30) or ceramic (n = 30) femoral head coupled with highly cross-linked polyethylene. Cobalt, chromium, and nickel ions were measured. RESULTS Patients with metal heads had detectable cobalt and chromium levels. Cobalt levels were detectable in 17 (56.7%) patients with a mean of 2.0 μg/L (range: <1.0-10.8 μg/L). Chromium levels were detectable in 5 (16.7%) patients with a mean of 0.3 μg/L (range: <1.0-2.2 μg/L). All patients with a ceramic head had nondetectable cobalt and chromium levels. Cobalt and chromium levels were significantly higher with metal heads compared to ceramic heads (P < .01). Cobalt levels were significantly higher with 36-mm metal heads compared with 32-mm heads (P < .01). Seven patients with metal femoral heads had mild hip symptoms, 4 of whom had positive findings of early adverse local tissue reaction on magnetic resonance imaging. All ceramic THA was asymptomatic. CONCLUSION The incidence and magnitude of cobalt and chromium levels is higher in metal heads compared to ceramic heads with this implant system (P < .01). Thirty-six millimeter metal femoral heads result in larger levels of cobalt compared with 32-mm metal heads.
Collapse
|
41
|
Is Metal-On-Metal Total Hip Arthroplasty Associated With Neurotoxicity? J Arthroplasty 2016; 31:233-236.e1. [PMID: 27118351 DOI: 10.1016/j.arth.2016.03.035] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2015] [Revised: 03/07/2016] [Accepted: 03/17/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Isolated case reports in the literature describe systemic neurologic side effects associated with metal-on-metal (MOM) bearing surfaces, yet the incidence of these effects have not been evaluated beyond individual cases. The purpose of this study was to compare new diagnoses of these side effects described in isolated cases in large patient cohorts of MOM vs metal on polyethylene (MOP). METHODS We queried the entire Medicare database from 2005 to 2012. Total hip arthroplasty (THA) and bearing surface were determined using International Classification of Diseases, 9th revision procedure codes. Patients with 5-year follow-up were selected. Using International Classification of Diseases, 9th revision codes, we identified new diagnoses of previously reported neurologic side effects: peripheral neuropathy, sensorineural hearing loss, visual impairment, paresthesias, tinnitus, and vertigo. Comorbidities and demographics were collected. Odds ratios, CIs, and P values were calculated. RESULTS Overall, 29,483 MOM THAs and 23,587 age- and gender-matched MOP THAs were identified. The average Charlson Comorbidity Index was 5 for both groups. MOM and MOP patients had 26 of 30 identical prevalence of Elixhauser-measure comorbidities. There was no statistically significant difference in new diagnoses of any of the side effects at any time point between the 2 groups over 5 years. CONCLUSION This study represents, to our knowledge, the first longitudinal analysis of systemic neurotoxicity after THA in a large cohort of patients. The results of our study suggest that on the large scale, neurologic side effects previously described do not occur as a common attributable complication. Rather, these cases may be due to individual patient hypersensitivity to metal ions.
Collapse
|
42
|
Cobalt Alloy Implant Debris Induces Inflammation and Bone Loss Primarily through Danger Signaling, Not TLR4 Activation: Implications for DAMP-ening Implant Related Inflammation. PLoS One 2016; 11:e0160141. [PMID: 27467577 PMCID: PMC4965114 DOI: 10.1371/journal.pone.0160141] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2015] [Accepted: 05/18/2016] [Indexed: 11/20/2022] Open
Abstract
Cobalt alloy debris has been implicated as causative in the early failure of some designs of current total joint implants. The ability of implant debris to cause excessive inflammation via danger signaling (NLRP3 inflammasome) vs. pathogen associated pattern recognition receptors (e.g. Toll-like receptors; TLRs) remains controversial. Recently, specific non-conserved histidines on human TLR4 have been shown activated by cobalt and nickel ions in solution. However, whether this TLR activation is directly or indirectly an effect of metals or secondary endogenous alarmins (danger-associated molecular patterns, DAMPs) elicited by danger signaling, remains unknown and contentious. Our study indicates that in both a human macrophage cell line (THP-1) and primary human macrophages, as well as an in vivo murine model of inflammatory osteolysis, that Cobalt-alloy particle induced NLRP3 inflammasome danger signaling inflammatory responses were highly dominant relative to TLR4 activation, as measured respectively by IL-1β or TNF-α, IL-6, IL-10, tissue histology and quantitative bone loss measurement. Despite the lack of metal binding histidines H456 and H458 in murine TLR4, murine calvaria challenge with Cobalt alloy particles induced significant macrophage driven in vivo inflammation and bone loss inflammatory osteolysis, whereas LPS calvaria challenge alone did not. Additionally, no significant increase (p<0.05) in inflammation and inflammatory bone loss by LPS co-challenge with Cobalt vs. Cobalt alone was evident, even at high levels of LPS (i.e. levels commiserate with hematogenous levels in fatal sepsis, >500pg/mL). Therefore, not only do the results of this investigation support Cobalt alloy danger signaling induced inflammation, but under normal homeostasis low levels of hematogenous PAMPs (<2pg/mL) from Gram-negative bacteria, seem to have negligible contribution to the danger signaling responses elicited by Cobalt alloy metal implant debris. This suggests the unique nature of Cobalt alloy particle bioreactivity is strong enough to illicit danger signaling that secondarily activate concomitant TLR activation, and may in part explain Cobalt particulate associated inflammatory and toxicity-like reactions of specific orthopedic implants.
Collapse
|
43
|
Metallosis with pseudotumour formation: Long-term complication following cementless total hip replacement in a dog. Vet Comp Orthop Traumatol 2016; 29:283-9. [PMID: 27189390 DOI: 10.3415/vcot-16-02-0028] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2016] [Accepted: 04/25/2016] [Indexed: 02/08/2023]
Abstract
CASE DESCRIPTION A 10-year-old female Belgian Teruven dog was presented to our clinic for total hip revision following a diagnosis of implant (cup) failure with metallosis and abdominal pseudotumour formation. The patient had a cementless metal-on-polyethylene total hip replacement performed nine years prior to presentation. CLINICAL FINDINGS The clinical findings, including pseudotumour formation locally and at sites distant from the implant and pain associated with the joint replacement, were similar to those described in human patients with this condition. Histopathological, surgical, and radiographic findings additionally supported the diagnosis of metallosis and pseudotumour formation. TREATMENT AND OUTCOME Distant site pseudotumours were surgically removed and the total hip replacement was explanted due to poor bone quality. The patient recovered uneventfully and has since resumed normal activity. CONCLUSION In veterinary patients with metal-on-polyethylene total hip implants, cup failure leading to metallosis and pseudotumour formation should be considered as a potential cause of ipsilateral hindlimb lameness, intra-pelvic abdominal tumours, or a combination of both. These clinical findings may occur years after total hip replacement surgery.
Collapse
|
44
|
Quantitative analysis of orthopedic metal artefact reduction in 64-slice computed tomography scans in large head metal-on-metal total hip replacement, a phantom study. SPRINGERPLUS 2016; 5:405. [PMID: 27047731 PMCID: PMC4818838 DOI: 10.1186/s40064-016-2006-y] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/11/2015] [Accepted: 03/15/2016] [Indexed: 01/27/2023]
Abstract
PURPOSE Quantification of the effect of O-MAR on decreasing metal artefacts caused by large head metal on metal total hip arthroplasty (MoM THA) in a dedicated phantom setup of the hip. BACKGROUND Pathological reactions of the hip capsule on Computed tomography (CT) can be difficult to diagnose due to different metal artefacts. The O-MAR algorithm deploys an iterative loop where the metal sinogram is identified, extracted, and subsequently serves as a mask to correct the measured sinogram. Main goal of this study is to quantify the ability of the O-MAR technique to correct deviation in medullary bone attenuation caused by streak artefacts from the large-head MoM THA embedded in a phantom. Secondary goal is to evaluate the influence of O-MAR on CNR. METHODS The phantom was designed as a Perspex box (PMMA) containing water and a supplementary MOM THA surrounded by Perspex columns comprising calibrated calcium pellets. Each column contains 200 mg of hydroxyapatite/calcium carbonate to simulate healthy bone tissue. Scans were obtained with and without a MoM THA at different dose levels. Different reconstructions were made with filter A, iDose(4) level 5 and with and without O-MAR. The scans without the prosthesis were used as the baseline. Information about the attenuation in Hounsfield units, image noise in standard deviation within the ROI's were extracted and the CNR was calculated. RESULTS Pellet L0 and R0 (proximal of the MoM THA) were defined as reference, lacking any disturbance by metal artefacts; L5, L6 and L8 were respectively visually categorized as 'light' 'medium' and 'heavy disturbance'. Significant improvements in attenuation deviation caused by metal artefact were 43, 68 and 32 %, for respectively pellet L5, L6 and L8 (p < 0.001). Significant CNR improvements were present for L5 and L6 and were respectively 72 and 52 % (p < 0.001). O-MAR showed no improvement on CNR for L8. CONCLUSION This phantom study significantly increases image quality by the use of O-MAR in the presence of metal artefacts by significantly reducing metal artefacts subsequently and increasing CNR on a 64 slice CT system in light and medium disturbance of the image.
Collapse
|
45
|
Silverman EJ, Ashley B, Sheth NP. Metal-on-metal total hip arthroplasty: is there still a role in 2016? Curr Rev Musculoskelet Med 2016; 9:93-6. [PMID: 26791173 DOI: 10.1007/s12178-016-9323-1] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
The use of metal-on-metal (MoM) bearings in total hip arthroplasty (THA) was popularized due to its enhanced wear profile and the ability to use large femoral heads to reduce post-operative instability. However, enthusiasm for the bearing declined following serious complications encountered at the primary articulation. This review discusses the development of MoM and the subsequent unexpected downstream challenges, most notably elevated serum metal ion levels, aseptic lymphocyte-dominated vasculitis-associated lesions (ALVAL), pseudotumor formation, and subsequent soft tissue and bone destruction. Both patient centered risk factors as well as component design led to high early failure rates resulting in product recalls and an overall decline in the use of MoM. In 2016, there is not a role for large-head MoM bearing in THA. Alternatively, the bearing has shown promise in hip resurfacing procedures for carefully selected patients.
Collapse
Affiliation(s)
- Edward J Silverman
- Department of Orthopaedics, The University of Pennsylvania Health System, 800 Spruce Street, Philadelphia, PA, 19107, USA.
| | - Blair Ashley
- Department of Orthopaedics, The University of Pennsylvania Health System, 800 Spruce Street, Philadelphia, PA, 19107, USA.
| | - Neil P Sheth
- Department of Orthopaedics, The University of Pennsylvania Health System, 800 Spruce Street, Philadelphia, PA, 19107, USA.
| |
Collapse
|
46
|
Harrington K, Phelan E, Torreggiani WC, Doody O. The Management of the Symptomatic Patient With a Metal-on-Metal Hip Prosthesis. Can Assoc Radiol J 2016; 67:76-81. [PMID: 26800622 DOI: 10.1016/j.carj.2015.10.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2015] [Revised: 09/28/2015] [Accepted: 10/05/2015] [Indexed: 11/26/2022] Open
Abstract
Metal-on-metal (MoM) hip implants have gained popularity due to their greater stability and reduction in implant failure compare to metal-on-polyethylene prostheses. However, as well as carrying general risks of hip implantation, risks specifically associated with MoM implants have been well documented in recent years. Conditions such as pseudotumours or aseptic lymphocyte-dominated vasculitis-associated lesions are specific to MoM hip implants. In this review we discuss the typical patient presentation, the investigations that should be performed, the typical findings on various imaging modalities, and the treatment options of symptomatic patients with MoM hip arthroplasties.
Collapse
Affiliation(s)
- Kate Harrington
- Radiology Department, The Adelaide and Meath Hospital Dublin, Incorporating the National Children's Hospital, Dublin, Ireland.
| | - Emma Phelan
- Radiology Department, The Adelaide and Meath Hospital Dublin, Incorporating the National Children's Hospital, Dublin, Ireland
| | - William C Torreggiani
- Radiology Department, The Adelaide and Meath Hospital Dublin, Incorporating the National Children's Hospital, Dublin, Ireland
| | - Orla Doody
- Radiology Department, The Adelaide and Meath Hospital Dublin, Incorporating the National Children's Hospital, Dublin, Ireland
| |
Collapse
|
47
|
CORR Insights(®): do patients with a failed metal-on-metal hip implant with a pseudotumor present differences in their peripheral blood lymphocyte subpopulations? Clin Orthop Relat Res 2015; 473:3915-7. [PMID: 26463565 PMCID: PMC4626502 DOI: 10.1007/s11999-015-4571-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2015] [Accepted: 09/21/2015] [Indexed: 01/31/2023]
|
48
|
Sarhadi VK, Parkkinen J, Reito A, Nieminen J, Porkka N, Wirtanen T, Laitinen M, Eskelinen A, Knuutila S. Genetic alterations in periprosthetic soft-tissue masses from patients with metal-on-metal hip replacement. Mutat Res 2015; 781:1-6. [PMID: 26355908 DOI: 10.1016/j.mrfmmm.2015.08.006] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2015] [Revised: 07/23/2015] [Accepted: 08/27/2015] [Indexed: 02/06/2023]
Abstract
Adverse soft tissue reactions in patients with metal-on-metal (MoM) hip replacement are associated with cobalt (Co) and chromium (Cr) particles released from the implant. Exposing the patients to long periods of increased metal ions concentrations resulting from the wear of these implants poses an increased risk of genotoxicity/mutagenicity. A variable proportion of patients develop periprosthetic soft-tissue masses or pseudotumors at the site of the implant. There is a concern that exposure to increased metal ions could increase the risk of cancer. In order to investigate whether the periprosthetic soft-tissue mass harbours any cancer- related genetic alterations, we studied DNA isolated from periprosthetic tissues of 20 patients with MoM hip replacement, for copy number alterations and mutations in hotspot regions of 50 cancer genes using aCGH and amplicon-based next generation sequencing. Our results showed copy number gains at 12q14.3 and 21q21.1in tumour from patient diagnosed with liposarcoma. Copy number alterations in periprosthetic tissues were seen in three other patients, one had a region of gain at 9q24.1 affecting JAK2 and INSL6, and two patients had region of gain at 6p21.1, affecting RUNX2. Mutation analysis showed V1578del mutation in NOTCH1 in two patients. The copy number alterations and mutations seen in periprosthetic soft-tissue masses are earlier reported in either haematological malignancies or in osteoblast related bone dysplasia. The presence of genetic anomalies was associated with longer in-situ time of the implant. Our findings warrant the need of similar studies in larger patient cohorts to evaluate the risk of development of neoplastic alterations in periprosthetic tissues of patients with MoM hip replacement.
Collapse
Affiliation(s)
- Virinder Kaur Sarhadi
- University of Helsinki, Faculty of Medicine, Department of Pathology, Helsinki, Finland
| | - Jyrki Parkkinen
- Coxa Hospital for Joint Replacement, Tampere, Finland; Department of Pathology, FIMLAB Laboratories, Tampere, Finland
| | - Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | | - Noora Porkka
- University of Helsinki, Faculty of Medicine, Department of Pathology, Helsinki, Finland
| | - Tiina Wirtanen
- University of Helsinki, Faculty of Medicine, Department of Pathology, Helsinki, Finland; HUSLAB, Department of Pathology, Helsinki University Central Hospital, Helsinki, Finland
| | | | | | - Sakari Knuutila
- University of Helsinki, Faculty of Medicine, Department of Pathology, Helsinki, Finland.
| |
Collapse
|
49
|
Development and first validation of a simplified CT-based classification system of soft tissue changes in large-head metal-on-metal total hip replacement: intra- and interrater reliability and association with revision rates in a uniform cohort of 664 arthroplasties. Skeletal Radiol 2015; 44:1141-9. [PMID: 25943898 DOI: 10.1007/s00256-015-2146-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2014] [Revised: 03/20/2015] [Accepted: 03/30/2015] [Indexed: 02/02/2023]
Abstract
OBJECTIVE After implantation of a metal-on-metal total hip arthroplasty (MoM THA), a large incidence of pseudotumor formation has been described recently. Several centers have invited patients for follow-up in order to screen for pseudotumor formation. The spectrum of abnormalities found by CT in MoM THA patients can be unfamiliar to radiologists and orthopedic surgeons. Previously, a CT five-point grading scale has been published. In this paper, a simplification into a three-point classification system gives insight in the morphological distinction of abnormalities of the postoperative hip capsule in MoM implants in relation to the decision for revision. The reliability of this simplified classification regarding intra- and interrater reliability and its association with revision rate is investigated and discussed. MATERIALS AND METHODS All patients who underwent MoM THA in our hospital were invited for screening. Various clinical measures and CT scan were obtained in a cross-sectional fashion. A decision on revision surgery was made shortly after screening. CT scans were read in 582 patients, of which 82 patients were treated bilaterally. CT scans were independently single read by two board-certified radiologists and classified into categories I-V. In a second meeting, consensus was obtained. Categories were subsequently rubricated in class A (categories I and II), B (category III), and C (categories IV and V). Intra- and inter-radiologist agreement on MoM pathology was assessed by means of the weighted Cohen's kappa. Categorical data were presented as n (%), and tested by means of Fisher's exact test. Continuous data were presented as median (min-max) and tested by means of Mann-Whitney U test (two group comparison) or Kruskal-Wallis test (three group comparison). Logistic regression analysis was performed in order to study independence of CT class for association with revision surgery. Univariate statistically significant variables were entered in a multiple model. All statistical analysis was performed two-tailed using alpha 5% as the significance level. RESULTS In total, 664 scores from 664 MoM hips obtained by two observers were available for analyses. Interobserver reliability for the non-simplified version (I-V) was κw = 0.71 (95% CI: 0.62-0.79), which indicates good agreement between the two musculoskeletal radiologists. Intra- and interobserver reliability for the simplified version (A-C) were respectively κw 0.78 (95% CI: 0.68-0.87), and κw = 0.71 (95% CI: 0.65-0.76). This indicates good agreement within and between the two observers. The simplified A-C version is significantly associated with revision exclusively due to MoM pathology, in both patients with unilateral MoM THA (p < 0.001) and patients with bilateral MoM THA (p < 0.044). The simplified A-C version is associated with several clinical measures. In patients with unilateral MoM THA, with or without contralateral THA, in situ time (p < 0.008), cobalt and chromium (p < 0.001) were statistically significant. In patients with bilateral MoM, cobalt (p < 0.001) and chromium (p < 0.027) were statistically significant. Revision is significantly associated with cup size (p < 0.001), anteversion of the cup (p < 0.004), serum ion levels of cobalt and chromium (p < 0.001) and the adapted classification system (p < 0.001). In univariate logistic regression analysis on revision, cup, anteversion of the cup, cobalt-chromium ion serum levels, and the simplified (A-C) CT category system were statistically significant. The simplified (A-C) CT category system was an independent associate of revision, in several multiple logistic regression models. CONCLUSIONS The presented simplified CT grading system (A-C) in its first clinical validation on 48- and 64-multislice systems is reliable, showing good intra- and interrater reliability and is independently associated with revision surgery.
Collapse
|
50
|
Metal-on-Metal Hip Arthroplasty: A Review of Adverse Reactions and Patient Management. J Funct Biomater 2015; 6:486-99. [PMID: 26132653 PMCID: PMC4598667 DOI: 10.3390/jfb6030486] [Citation(s) in RCA: 93] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2015] [Revised: 06/12/2015] [Accepted: 06/18/2015] [Indexed: 01/18/2023] Open
Abstract
Recent alarming joint registry data highlighting increased revision rates has prompted further research into the area of metal-on-metal hip replacements and resurfacings. This review article examines the latest literature on the topic of adverse reactions to metal debris and summarises the most up-to-date guidelines on patient management. Adverse reactions to metal debris can cause significant damage to soft tissue and bone if not diagnosed early. Furthermore, not every patient with an adverse reaction to metal debris will be symptomatic. As such, clinicians must remain vigilant when assessing and investigating these patients in order to detect failing implants and initiate appropriate management.
Collapse
|