1
|
Fadel MG, Tarazi M, Dave M, Reddy M, Khan O, Fakih-Gomez N, Ashrafian H, Fehervari M. Magnetic sphincter augmentation in the management of gastro-esophageal reflux disease: A systematic review and meta-analysis. Int J Surg 2024; 110:01279778-990000000-01449. [PMID: 38729117 PMCID: PMC11487049 DOI: 10.1097/js9.0000000000001558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Accepted: 04/23/2024] [Indexed: 05/12/2024]
Abstract
BACKGROUND Magnetic sphincter augmentation (MSA) through placement of the LINX device is an alternative to fundoplication in the management of gastro-esophageal reflux disease (GERD). This systematic review and meta-analysis aimed to assess efficacy, quality of life and safety in patients that underwent MSA, with a comparison to fundoplication. METHODS A literature search of MEDLINE, Embase, Emcare, Scopus, Web of Science and Cochrane library databases was performed for studies that reported data on outcomes of MSA, with or without a comparison group undergoing fundoplication, for GERD from January 2000 to January 2023. Meta-analysis was performed using random-effect models and between-study heterogeneity was assessed. RESULTS Thirty-nine studies with 8,075 patients were included: 6,983 patients underwent MSA and 1,092 patients had laparoscopic fundoplication procedure. Ten of these studies (seven retrospective and three prospective) directly compared MSA with fundoplication. A higher proportion of individuals successfully discontinued proton-pump inhibitors (P<0.001; WMD 0.83; 95% CI 0.72-0.93; I2=96.8%) and had higher patient satisfaction (P<0.001; WMD 0.85; 95% CI 0.78-0.93; I2=85.2%) following MSA when compared to fundoplication. Functional outcomes were better after MSA than after fundoplication including ability to belch (P<0.001; WMD 0.96; 95% CI 0.93-0.98; I2=67.8) and emesis (P<0.001; WMD 0.92; 95% CI 0.89-0.95; I2=42.8%), and bloating (P=0.003; WMD 0.20; 95% CI 0.07-0.33; I2=97.0%). MSA had higher rates of dysphagia (P=0.001; WMD 0.41; 95% CI 0.17-0.65; I2=97.3%) when compared to fundoplication. The overall erosion and removal rate following MSA was 0.24% and 3.9% respectively, with no difference in surgical re-intervention rates between MSA and fundoplication (P=0.446; WMD 0.001; 95% CI -0.001-0.002; I2 =78.5%). CONCLUSIONS MSA is a safe and effective procedure at reducing symptom burden of GERD and can potentially improve patient satisfaction and functional outcomes. However, randomized controlled trials directly comparing MSA with fundoplication are necessary to determine where MSA precisely fits in the management pathway of GERD.
Collapse
Affiliation(s)
- Michael G. Fadel
- Department of Surgery and Cancer, Imperial College London
- Department of Bariatric and Metabolic Surgery, Chelsea and Westminster Hospital, London
| | - Munir Tarazi
- Department of Surgery and Cancer, Imperial College London
| | - Madhav Dave
- Department of Gastrointestinal Surgery, Maidstone and Tunbridge Wells NHS Trust, United Kingdom
| | | | - Omar Khan
- Department of Bariatric Surgery
- Population Sciences Department, St George’s University of London
| | - Naim Fakih-Gomez
- Department of Bariatric and Metabolic Surgery, Chelsea and Westminster Hospital, London
| | | | - Matyas Fehervari
- Department of Surgery and Cancer, Imperial College London
- Department of Upper Gastrointestinal Surgery, Liverpool University Hospitals, Liverpool
| |
Collapse
|
2
|
Froiio C, Aiolfi A, Bona D, Bonavina L. Safety profile of magnetic sphincter augmentation for gastroesophageal reflux disease. Front Surg 2023; 10:1293270. [PMID: 38026489 PMCID: PMC10661944 DOI: 10.3389/fsurg.2023.1293270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Accepted: 10/23/2023] [Indexed: 12/01/2023] Open
Abstract
Background The magnetic sphincter augmentation (MSA) procedure is an effective treatment for gastroesophageal reflux disease (GERD). Adverse events requiring MSA device removal are rare, but the true prevalence and incidence may be underestimated. Methods Retrospective study on a prospectively collected database. Patients who underwent MSA procedure between March 2007 and September 2021 in two tertiary-care referral centers for esophageal surgery were included. The trend of MSA explant, the changes in the sizing technique and crura repair over the years, the technique of explant, and the clinical outcomes of the revisional procedure were reviewed. Results Out of 397 consecutive patients, 50 (12.4%) underwent MSA removal, with a median time to explant of 39.5 [IQR = 53.7] months. Main symptoms leading to removal were dysphagia (43.2%), heartburn (25%), and epigastric pain (13.6%). Erosion occurred in 2.5% of patients. Smaller (12- and 13-bead) devices were the ones most frequently explanted. The majority of the explants were performed laparoscopically with endoscopic assistance. There was no perioperative morbidity, and the median length of stay was 2.8 ± 1.4 days. After 2014, changes in sizing technique and crura repair resulted in a decreased incidence of explants from 23% to 5% (p < 0.0001). Multivariate analysis confirmed the protective role of added bead units [HR 0.06 (95% CI = 0.001-0.220); p < 0.000]. Conclusion Oversizing and full mediastinal dissection with posterior hiatoplasty may improve the outcomes of the MSA procedure and possibly reduce removal rates.
Collapse
Affiliation(s)
- Caterina Froiio
- Department of Biomedical Science for Health, Division of General and Foregut Surgery, IRCCS Policlinico San Donato, University of Milan, Milan, Italy
| | - Alberto Aiolfi
- Department of Biomedical Science for Health, Division of General Surgery, IRCCS Galeazzi-Sant’Ambrogio, University of Milan, Milan, Italy
| | - Davide Bona
- Department of Biomedical Science for Health, Division of General Surgery, IRCCS Galeazzi-Sant’Ambrogio, University of Milan, Milan, Italy
| | - Luigi Bonavina
- Department of Biomedical Science for Health, Division of General and Foregut Surgery, IRCCS Policlinico San Donato, University of Milan, Milan, Italy
| |
Collapse
|
3
|
Reiter AJ, Farina DA, Fronza JS, Komanduri S. Magnetic sphincter augmentation: considerations for use in Barrett's esophagus. Dis Esophagus 2023; 36:doac096. [PMID: 36575922 PMCID: PMC10267686 DOI: 10.1093/dote/doac096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 11/11/2022] [Accepted: 11/23/2022] [Indexed: 12/29/2022]
Abstract
Barrett's esophagus (BE) occurs in 5-15% of patients with gastroesophageal reflux disease (GERD). While acid suppressive therapy is a critical component of BE management to minimize the risk of progression to esophageal adenocarcinoma, surgical control of mechanical reflux is sometimes necessary. Magnetic sphincter augmentation (MSA) is an increasingly utilized anti-reflux surgical therapy for GERD. While the use of MSA is listed as a precaution by the United States Food and Drug Administration, there are limited data showing effective BE regression with MSA. MSA offers several advantages in BE including effective reflux control, anti-reflux barrier restoration and reduced hiatal hernia recurrence. However, careful patient selection for MSA is necessary.
Collapse
Affiliation(s)
- Audra J Reiter
- Department of Surgery, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Domenico A Farina
- Department of Gastroenterology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Jeffrey S Fronza
- Department of Surgery, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Srinadh Komanduri
- Department of Gastroenterology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| |
Collapse
|
4
|
Toniolo I, Mascolini MV, Carniel EL, Fontanella CG. Artificial sphincters: An overview from existing devices to novel technologies. Artif Organs 2023; 47:617-639. [PMID: 36374175 DOI: 10.1111/aor.14434] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 09/21/2022] [Accepted: 10/11/2022] [Indexed: 11/16/2022]
Abstract
Artificial sphincters (ASs) are used to replace the function of the biological sphincters in case of severe urinary and fecal incontinence (UI and FI), and gastroesophageal reflux disease (GERD). The design of ASs is established on different mechanisms, e.g., magnetic forces or hydraulic pressure, with the final goal to achieve a implantable and durable AS. In clinical practice, the implantation of in-commerce AS is considered a reasonable solution, despite the sub-optimal clinical outcomes. The failure of these surgeries is due to the malfunction of the devices (between 46 and 51%) or the side effects on the biological tissues (more than 38%), such as infection and atrophy. Concentrating on this latter characteristic, particular attention has been given to the interaction between the biological tissues and AS, pointing out the closing mechanism around the duct and the effect on the tissues. To analyze this aspect, an overview of existing commercial/ready-on-market ASs for GERD, UI, and FI, together with the clinical outcomes available from the in-commerce AS, is given. Moreover, this invited review discusses ongoing developments and future research pathways for creating novel ASs. The application of engineering principles and design concepts to medicine enhances the quality of healthcare and improves patient outcomes. In this context, computational methods represent an innovative solution in the design of ASs, proving data on the occlusive force and pressure necessary to guarantee occlusion and avoid tissue damage, considering the coupling between different device sizes and individual variability.
Collapse
Affiliation(s)
- Ilaria Toniolo
- Department of Industrial Engineering, University of Padova, Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padova, Padova, Italy
| | - Maria Vittoria Mascolini
- Department of Industrial Engineering, University of Padova, Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padova, Padova, Italy
| | - Emanuele Luigi Carniel
- Department of Industrial Engineering, University of Padova, Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padova, Padova, Italy
| | - Chiara Giulia Fontanella
- Department of Industrial Engineering, University of Padova, Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padova, Padova, Italy
| |
Collapse
|
5
|
Patel A, Gyawali CP. The role of magnetic sphincter augmentation (MSA) in the gastroesophageal reflux disease (GERD) treatment pathway: the gastroenterology perspective. Dis Esophagus 2023:7034219. [PMID: 36776100 DOI: 10.1093/dote/doad005] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 01/18/2023] [Indexed: 02/14/2023]
Abstract
Magnetic sphincter augmentation (MSA) is a surgical intervention for well-characterized gastroesophageal reflux disease (GERD), where the esophagogastric junction barrier is augmented using a bracelet of magnetized titanium beads. MSA could be an attractive option for patients with documented GERD who wish to avoid long-term pharmacologic therapy or whose symptoms are not adequately managed with lifestyle modifications and pharmacologic therapy. The 'ideal' MSA patient is one with prominent regurgitation, without dysphagia or esophageal motor dysfunction, with objective evidence of GERD on upper endoscopy and/or ambulatory reflux monitoring. Appropriate candidates with significant hiatus hernia may pursue MSA with concomitant hiatus hernia repair. The increasing adoption of MSA in the GERD treatment pathway reflects research that shows benefits in long-term outcomes and healthcare costs compared with other established therapies in appropriate clinical settings.
Collapse
Affiliation(s)
- Amit Patel
- Division of Gastroenterology, Duke University School of Medicine and the Durham VA Medical Center, Durham, NC, USA
| | - C Prakash Gyawali
- Division of Gastroenterology, Washington University School of Medicine, Saint Louis, MO, USA
| |
Collapse
|
6
|
Removal of the magnetic sphincter augmentation device: an assessment of etiology, clinical presentation, and management. Surg Endosc 2023; 37:3769-3779. [PMID: 36689039 PMCID: PMC10156860 DOI: 10.1007/s00464-023-09878-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Accepted: 01/08/2023] [Indexed: 01/24/2023]
Abstract
BACKGROUND Magnetic sphincter augmentation (MSA) erosion, disruption or displacement clearly requires device removal. However, up to 5.5% of patients without anatomical failure require removal for dysphagia or recurrent GERD symptoms. Studies characterizing these patients or their management are limited. We aimed to characterize these patients, compare their outcomes, and determine the necessity for further reflux surgery. METHODS This is a retrospective review of 777 patients who underwent MSA at our institution between 2013 and 2021. Patients who underwent device removal for persistent dysphagia or recurrent GERD symptoms were included. Demographic, clinical, objective testing, and quality of life data obtained preoperatively, after implantation and following removal were compared between removal for dysphagia and GERD groups. Sub-analyses were performed comparing outcomes with and without an anti-reflux surgery (ARS) at the time of removal. RESULTS A total of 40 (5.1%) patients underwent device removal, 31 (77.5%) for dysphagia and 9 (22.5%) for GERD. After implantation, dysphagia patients had less heartburn (12.9-vs-77.7%, p = 0.0005) less regurgitation (16.1-vs-55.5%, p = 0.0286), and more pH-normalization (91.7-vs-33.3%, p = 0.0158). Removal without ARS was performed in 5 (55.6%) GERD and 22 (71.0%) dysphagia patients. Removal for dysphagia patients had more complete symptom resolution (63.6-vs-0.0%, p = 0.0159), freedom from PPIs (81.8-vs-0.0%, p = 0.0016) and pH-normalization (77.8-vs-0.0%, p = 0.0455). Patients who underwent removal for dysphagia had comparable symptom resolution (p = 0.6770, freedom from PPI (p = 0.3841) and pH-normalization (p = 0.2534) with or without ARS. Those who refused ARS with removal for GERD had more heartburn (100.0%-vs-25.0%, p = 0.0476), regurgitation (80.0%-vs-0.0%, p = 0.0476) and PPI use (75.0%-vs-0.0%, p = 0.0476). CONCLUSIONS MSA removal outcomes are dependent on the indication for removal. Removal for dysphagia yields excellent outcomes regardless of anti-reflux surgery. Patients with persistent GERD had worse outcomes on all measures without ARS. We propose a tailored approach to MSA removal-based indication for removal.
Collapse
|
7
|
Froiio C, Tareq A, Riggio V, Siboni S, Bonavina L. Real-world evidence with magnetic sphincter augmentation for gastroesophageal reflux disease: a scoping review. Eur Surg 2023. [DOI: 10.1007/s10353-022-00789-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Summary
Background
The burden of gastroesophageal reflux disease (GERD) is high, with up to 30% of the Western population reporting reflux-related symptoms with or without hiatal hernia. Magnetic sphincter augmentation (MSA) is a standardized laparoscopic procedure for patients who are dissatisfied with medical therapy and for those with early-stage disease who would not usually be considered ideal candidates for fundoplication. The MSA device is manufactured in different sizes and is designed to augment the physiologic barrier to reflux by magnetic force.
Methods
An extensive scoping review was performed to provide a map of current evidence with respect to MSA, to identify gaps in knowledge, and to make recommendations for future research. All the authors contributed to the literature search in PubMed and Web of Science and contributed to summarizing the evidence.
Results
Magnetic sphincter augmentation, especially in combination with crural repair, is effective in reducing GERD symptoms, proton pump inhibitor use, and esophageal acid exposure, and in improving patients’ quality of life. Safety issues such as device erosion or migration have been rare and not associated with mortality. The MSA device can be removed laparoscopically if necessary, thereby preserving the option of fundoplication or other therapies in the future. Contraindication to scanning in high-power Tesla magnetic resonance systems remains a potential limitation of the MSA procedure. High-resolution manometry and functional lumen imaging probes appear to be promising tools to predict procedural outcomes by improving reflux control and reducing the incidence of dysphagia.
Conclusion
A consensus on acquisition and interpretation of high-resolution manometry and impedance planimetry data is needed to gain better understanding of physiology, to improve patient selection, and to pave the way for a personalized surgical approach in antireflux surgery.
Collapse
|
8
|
Bell R. Is systematic formal crural repair mandatory at the time of magnetic sphincter augmentation implantation? Dis Esophagus 2023:6972914. [PMID: 36617229 DOI: 10.1093/dote/doac108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 10/21/2022] [Accepted: 12/06/2022] [Indexed: 01/09/2023]
Abstract
Laparoscopic placement of the LINX Magnetic Sphincter Augmentation (MSA) device has become an accepted alternative to fundoplication in appropriate patients. Initial studies of MSA targeted to patients with 'early' disease allowed for the most minimal dissection of the esophagus to place the device, without hiatal dissection or repair (NoHHR), in patients with no or minimal hernia findings at surgery. Subsequent studies have compared systematic formal hiatal dissection and repair (Formal HHR) with the original minimal dissection technique. Review of published literature on MSA includes discussion on treatment of hiatal hernia at the time of implantation, accompanying the review of the physiology of the crural diaphragm. Formal hiatal hernia repair at the time of MSA implantation results in better control of reflux with less dysphagia and risk of postoperative hernia than NoHHR, regardless of the presence or size of hiatal hernia. Systematic crural repair should accompany any MSA implantation regardless of the presence or size of hiatal hernia.
Collapse
Affiliation(s)
- Reginald Bell
- Institute of Esophageal and Reflux Surgery, Lone Tree, CO80124, USA
| |
Collapse
|
9
|
Sarici IS, Dunn CP, Eriksson SE, Jobe BA, Ayazi S. Long-term clinical and functional results of magnetic sphincter augmentation. Dis Esophagus 2022:6965898. [PMID: 36585776 DOI: 10.1093/dote/doac109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2022] [Indexed: 01/01/2023]
Abstract
Magnetic sphincter augmentation (MSA) was introduced in 2007 as an alternative surgical procedure for patients with gastroesophageal reflux disease (GERD). The majority of data since MSA's introduction has focused on short and intermediate-term results, demonstrating safety and high efficacy in terms of reflux symptom control, freedom from proton pump inhibitor use and normalization of distal esophageal acid exposure. However, GERD is a chronic condition that demands a long-term solution. Limited available data from studies reporting outcomes at 5 years or later following MSA demonstrate that the promising short- and mid-term efficacy and safety profile of MSA remains relatively constant in the long term. Compared with Nissen fundoplication, MSA has a much lower rate of gas-bloat and inability to belch at a short-term follow-up, a difference that persists in the long-term. The most common complaint after MSA at a short-term follow-up is dysphagia. However, limited data suggest dysphagia rates largely decrease by 5 years. Dysphagia is the most common indication for dilation and device removal in both early- and long-term studies. However, the overall rates of dilation and removal are similar in short- and long-term reports, suggesting the majority of these procedures are performed in the short-term period after device implantation. The indications and standard practices of MSA have evolved over time. Long-term outcome data currently available are all from patient cohorts who were selected for MSA under early restricted indications and outdated regimens. Therefore, further long-term studies are needed to corroborate the preliminary, yet encouraging long-term results.
Collapse
Affiliation(s)
- Inanc S Sarici
- Esophageal Institute, Department of Surgery, Allegheny Health Network, Pittsburgh, PA, USA
| | - Colin P Dunn
- Esophageal Institute, Department of Surgery, Allegheny Health Network, Pittsburgh, PA, USA
| | - Sven E Eriksson
- Esophageal Institute, Department of Surgery, Allegheny Health Network, Pittsburgh, PA, USA
| | - Blair A Jobe
- Esophageal Institute, Department of Surgery, Allegheny Health Network, Pittsburgh, PA, USA.,Department of Surgery, Drexel University, Philadelphia, PA, USA
| | - Shahin Ayazi
- Esophageal Institute, Department of Surgery, Allegheny Health Network, Pittsburgh, PA, USA.,Department of Surgery, Drexel University, Philadelphia, PA, USA
| |
Collapse
|
10
|
Siboni S, Bonavina L, Rogers BD, Egan C, Savarino E, Gyawali CP, DeMeester TR. Effect of Increased Intra-abdominal Pressure on the Esophagogastric Junction: A Systematic Review. J Clin Gastroenterol 2022; 56:821-830. [PMID: 36084164 PMCID: PMC9553247 DOI: 10.1097/mcg.0000000000001756] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
With the advent of high-resolution esophageal manometry, it is recognized that the antireflux barrier receives a contribution from both the lower esophageal sphincter (intrinsic sphincter) and the muscle of the crural diaphragm (extrinsic sphincter). Further, an increased intra-abdominal pressure is a major force responsible for an adaptive response of a competent sphincter or the disruption of the esophagogastric junction resulting in gastroesophageal reflux, especially in the presence of a hiatal hernia. This review describes how the pressure dynamics in the lower esophageal sphincter were discovered and measured over time and how this has influenced the development of antireflux surgery.
Collapse
Affiliation(s)
- Stefano Siboni
- Division of General and Foregut Surgery, Department of Biomedical Sciences for Health, University of Milan, IRCCS Policlinico San Donato, San Donato Milanese
| | - Luigi Bonavina
- Division of General and Foregut Surgery, Department of Biomedical Sciences for Health, University of Milan, IRCCS Policlinico San Donato, San Donato Milanese
| | | | - Ciara Egan
- Humanitas University, Humanitas Research Hospital, Rozzano, Milan
| | - Edoardo Savarino
- Gastroenterology Unit, Department of Surgery, Oncology, and Gastroenterology, University Hospital of Padova, Padova, Italy
| | | | - Tom R. DeMeester
- Emeritus, Keck School of Medicine, University of Southern California, Montague, MI
| |
Collapse
|
11
|
Bonavina L, Boyle N, Schoppmann SF. The role of magnetic sphincter augmentation in the treatment of gastroesophageal reflux disease. Curr Opin Gastroenterol 2021; 37:384-389. [PMID: 33883422 PMCID: PMC9904435 DOI: 10.1097/mog.0000000000000748] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
PURPOSE OF REVIEW Magnetic sphincter augmentation (MSA) has been designed as a less disruptive and more standardized laparoscopic surgical procedure than fundoplication for patients with early stage gastroesophageal reflux disease (GERD). We analyzed the more recent literature in search of updates regarding indications, technique, perioperative management, and long-term outcomes. RECENT FINDINGS Over the years, the procedure of MSA has evolved to including full hiatus repair rather than relying on the preservation of the phreno-esophageal ligament. Restoring the mechanical synergy between the lower esophageal sphincter and the crural diaphragm has the potential to further enhance the antireflux barrier. The adoption of this approach has led to expand the indications from early stage disease to different scenarios including patients with high esophageal acid exposure, atypical symptoms, large hiatal hernias, Barrett's esophagus, postbariatric surgery, and previously failed fundoplication. SUMMARY MSA has a favorable side-effect profile and is highly effective in reducing typical reflux symptoms, medication dependency, and esophageal acid exposure. Excellent outcomes have been confirmed over a 12-year follow-up, indicating that the operation has the potential to prevent GERD progression. Further studies are needed to confirm the cost-effectiveness of this procedure in patients with more advanced disease-stage and prior gastric surgery. A randomized control trial comparing MSA with fundoplication could raise the level of evidence and the strength of recommendation.
Collapse
Affiliation(s)
- Luigi Bonavina
- University of Milan, Department of Biomedical Sciences for Health, Division of General and Foregut Surgery, IRCCS Policlinico San Donato, Milan, Italy
| | - Nick Boyle
- King Edward VII Hospital, Medical Director RefluxUK, London, UK
| | - Sebastian F. Schoppmann
- Medical University of Vienna, Department of General Surgery, Upper-GI-Service, Wien, Austria
| |
Collapse
|