1
|
Zhang Y, Shao T, Zhang H. Electrochemical Sensors Based on Self-Assembling Peptide/Carbon Nanotube Nanocomposites for Sensitive Detection of Bisphenol A. SENSORS (BASEL, SWITZERLAND) 2024; 24:1465. [PMID: 38474999 DOI: 10.3390/s24051465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 02/08/2024] [Accepted: 02/19/2024] [Indexed: 03/14/2024]
Abstract
In this study, a cationic amphiphilic self-assembling peptide (SAP) Z23 was designed, and a simple bisphenol a (BPA) sensor, based on SAP Z23/multiwalled carbon nanotubes (Z23/MWCNTs) composite, was successfully fabricated on the surface of a glassy carbon electrode (GCE). The composite material was formed by π-π stacking interaction between the aromatic group on the hydrophobic side of Z23 and the side-wall of MWCNTs, with the charged hydrophilic group of Z23 exposed. During the electrocatalytic process of BPA, a synergistic effect was observed between Z23 and MWCNTs. The current response of the sensor based on composite material was 3.24 times that of the MWCNTs-modified electrode, which was much higher than that of the peptide-based electrode. Differential pulse voltammetry (DPV) was used to optimize the experimental conditions affecting the analytical performance of the modified electrode. Under optimal conditions, the linear range of the sensor was from 10 nM to 100 μM by amperometric measurement with sensitivity and limit of detection (LOD) at 6.569 μAμM-1cm-2 and 1.28 nM (S/N = 3), respectively. Consequently, the sensor has excellent electrochemical performance and is easy to fabricate, making it a good prospect in the field of electrochemical detection in the future.
Collapse
Affiliation(s)
- Yuhang Zhang
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian 116024, China
| | - Tingting Shao
- Liaoning Key Lab of Integrated Circuit and Biomedical Electronic System, Dalian University of Technology, Dalian 116024, China
| | - Hangyu Zhang
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian 116024, China
- Liaoning Key Lab of Integrated Circuit and Biomedical Electronic System, Dalian University of Technology, Dalian 116024, China
| |
Collapse
|
2
|
Chang F, Ren K, Li S, Su Q, Peng J, Tan J. A voltammetric sensor for bisphenol A using gold nanochains and carbon nanotubes. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2023; 252:114588. [PMID: 36724711 DOI: 10.1016/j.ecoenv.2023.114588] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 01/16/2023] [Accepted: 01/28/2023] [Indexed: 06/18/2023]
Abstract
Gold nanochains (AuNCs) were prepared, and this novel material was combined with carboxylated multi-walled carbon nanotubes (cMWCNTs) to be a nanocomposite for the first time. The transmission electron microscopy (TEM), scanning electron microscope (SEM), energy dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD) and UV-Vis spectra were used to characterize the successful preparation of AuNCs and AuNC-cMWCNT composite. Based on this hybrid material, a voltammetric sensor of bisphenol A (BPA) was established. The proposed sensor displayed excellent performance for the measurement of BPA by obvious decreased anodic peak potential and enlarged peak current. Using the optimized conditions, BPA was detected using linear sweep voltammetry, and the linear range showed as wide as 0.5 μM to 2000 μM with the detection limit estimated to be 12 nM (S/N = 3). The as-proposed sensor also exhibited satisfactory performance in determining BPA of actual plastic samples.
Collapse
Affiliation(s)
- Fengxia Chang
- School of Chemistry and Environment, Southwest Minzu University, Chengdu, PR China.
| | - Kai Ren
- School of Chemistry and Environment, Southwest Minzu University, Chengdu, PR China
| | - Sijing Li
- School of Chemistry and Environment, Southwest Minzu University, Chengdu, PR China
| | - Qianqian Su
- School of Chemistry and Environment, Southwest Minzu University, Chengdu, PR China
| | - Jiangping Peng
- School of Chemistry and Environment, Southwest Minzu University, Chengdu, PR China
| | - Jiong Tan
- School of Chemistry and Environment, Southwest Minzu University, Chengdu, PR China
| |
Collapse
|
3
|
Silva TA, Lourencao BC, Dias da Silva A, Fatibello-Filho O. An electrochemical sensing platform based on carbon black and chitosan-stabilized platinum nanoparticles. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:1077-1086. [PMID: 36752550 DOI: 10.1039/d2ay01964g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
The versatility of chitosan (Ch) biopolymer as a metallic nanoparticle stabilizing agent and excellent former of thin films on glassy carbon was explored in this work for the sustainable manufacture of novel electrochemical sensors based on carbon black (CB) and chitosan-stabilized platinum nanoparticles (Ch-PtNPs). Platinum nanoparticles highly stabilized by chitosan were easily synthesized at room temperature and characterized by HR-TEM, UV-vis, and voltammetry. Ch-PtNPs presented an average diameter of 2.7 nm, and typical voltammetric peaks of Pt in sulfuric acid medium were detected for films containing Ch-PtNPs. As a proof of concept, the CB-Ch-PtNP electrode was applied in the determination of hydrogen peroxide (H2O2) and the endocrine disruptor bisphenol A (BPA). Pronounced electrocatalytic activity towards H2O2 reduction was observed in the presence of Ch-PtNPs in the films, guaranteeing the non-enzymatic determination of H2O2 by chronoamperometry, with a limit of detection of 10 μmol L-1. In the determination of BPA by differential pulse adsorptive anodic stripping voltammetry (DPAdASV), under optimal experimental conditions, a wide linear response range and a limit of detection at the nanomolar level (7.9 nmol L-1) were achieved. In addition, excellent repeatabilities of sensor response and sensor fabrication, and accuracy in the analysis of natural water samples were obtained.
Collapse
Affiliation(s)
- Tiago Almeida Silva
- Department of Chemistry, Federal University of São Carlos, 13560-970, São Carlos, SP, Brazil.
- Department of Chemistry, Federal University of Viçosa, 36570-900, Viçosa, MG, Brazil
| | - Bruna Claudia Lourencao
- Department of Chemistry, Federal University of São Carlos, 13560-970, São Carlos, SP, Brazil.
- Minas Gerais State University, 38302-192, Ituiutaba, MG, Brazil
| | | | - Orlando Fatibello-Filho
- Department of Chemistry, Federal University of São Carlos, 13560-970, São Carlos, SP, Brazil.
| |
Collapse
|
4
|
Görmez Ö, Yakar E, Gözmen B, Kayan B, Khataee A. CoFe 2O 4 nanoparticles decorated onto graphene oxide and graphitic carbon nitride layers as a separable catalyst for ultrasound-assisted photocatalytic degradation of Bisphenol-A. CHEMOSPHERE 2022; 288:132663. [PMID: 34710453 DOI: 10.1016/j.chemosphere.2021.132663] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Revised: 10/18/2021] [Accepted: 10/23/2021] [Indexed: 06/13/2023]
Abstract
The advanced oxidation process (AOP) through ultrasound-assisted photocatalytic degradation has attracted much attention in removing emerging contaminants. Herein, CoFe2O4-GO and CoFe2O4-g-C3N4 nanocomposites were synthesized using the ultrasound-assisted co-precipitation method. TEM, XRD, XPS, EDS, SEM, and FT-IR techniques characterized the structural, morphological, and chemical properties of the synthesized nanocomposites. The analyses showed that CoFe2O4 structure was nano-sized and distributed more homogeneously in graphene oxide (GO) layers with oxygenated functional groups than graphitic carbon nitride (g-C3N4). While the efficiency of composite catalysts, as photocatalysts, for degradation of bisphenol-A (BPA) was low in the visible region in the presence of persulfate, their catalytic efficacy was higher with sonolytic activation. The addition of persulfate as an oxidant remarkably enhanced the target pollutant degradation and TOC removal of BPA solution. Both composite catalysts showed 100 % BPA removal with the synergistic effect of visible region photocatalytic oxidation and sonocatalytic oxidation in the presence of persulfate at pH 6.8. In ultrasound-assisted photocatalytic oxidation of BPA, the highest mineralization efficiencies were obtained at 2 h treatment time, pH 6.8, 16 mM PS, catalyst dosages of 0.1 g/L CoFe2O4-GO, and 0.4 g/L CoFe2O4-g-C3N4 as 62 % and 55 %, respectively. An effective catalyst was obtained by reducing e-/h+ recombination and charge transfer resistance by decorating the GO layers with CoFe2O4.
Collapse
Affiliation(s)
- Özkan Görmez
- Department of Chemistry, Arts and Science Faculty, Mersin University, 33343, Mersin, Turkey
| | - Ezgi Yakar
- Department of Chemistry, Arts and Science Faculty, Mersin University, 33343, Mersin, Turkey
| | - Belgin Gözmen
- Department of Chemistry, Arts and Science Faculty, Mersin University, 33343, Mersin, Turkey
| | - Berkant Kayan
- Department of Chemistry, Arts and Science Faculty, Aksaray University, 68100, Aksaray, Turkey
| | - Alireza Khataee
- Department of Environmental Engineering, Gebze Technical University, 41400, Gebze, Turkey; Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471, Tabriz, Iran.
| |
Collapse
|
5
|
Kanoun O, Lazarević-Pašti T, Pašti I, Nasraoui S, Talbi M, Brahem A, Adiraju A, Sheremet E, Rodriguez RD, Ben Ali M, Al-Hamry A. A Review of Nanocomposite-Modified Electrochemical Sensors for Water Quality Monitoring. SENSORS (BASEL, SWITZERLAND) 2021; 21:4131. [PMID: 34208587 PMCID: PMC8233775 DOI: 10.3390/s21124131] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 05/31/2021] [Accepted: 06/02/2021] [Indexed: 12/12/2022]
Abstract
Electrochemical sensors play a significant role in detecting chemical ions, molecules, and pathogens in water and other applications. These sensors are sensitive, portable, fast, inexpensive, and suitable for online and in-situ measurements compared to other methods. They can provide the detection for any compound that can undergo certain transformations within a potential window. It enables applications in multiple ion detection, mainly since these sensors are primarily non-specific. In this paper, we provide a survey of electrochemical sensors for the detection of water contaminants, i.e., pesticides, nitrate, nitrite, phosphorus, water hardeners, disinfectant, and other emergent contaminants (phenol, estrogen, gallic acid etc.). We focus on the influence of surface modification of the working electrodes by carbon nanomaterials, metallic nanostructures, imprinted polymers and evaluate the corresponding sensing performance. Especially for pesticides, which are challenging and need special care, we highlight biosensors, such as enzymatic sensors, immunobiosensor, aptasensors, and biomimetic sensors. We discuss the sensors' overall performance, especially concerning real-sample performance and the capability for actual field application.
Collapse
Affiliation(s)
- Olfa Kanoun
- Professorship Measurement and Sensor Technology, Chemnitz University of Technology, 09111 Chemnitz, Germany; (S.N.); (M.T.); (A.B.); (A.A.); (A.A.-H.)
| | - Tamara Lazarević-Pašti
- Department of Physical Chemistry, “VINČA” Institute of Nuclear Sciences—National Institute of the Republic of Serbia, University of Belgrade, 11000 Belgrade, Serbia;
| | - Igor Pašti
- Faculty of Physical Chemistry, University of Belgrade, 11000 Belgrade, Serbia;
| | - Salem Nasraoui
- Professorship Measurement and Sensor Technology, Chemnitz University of Technology, 09111 Chemnitz, Germany; (S.N.); (M.T.); (A.B.); (A.A.); (A.A.-H.)
- NANOMISENE Lab, LR16CRMN01, Centre for Research on Microelectronics and Nanotechnology of Sousse, Technopole of Sousse B.P. 334, Sahloul, Sousse 4034, Tunisia;
- Higher Institute of Applied Sciences and Technology of Sousse, University of Sousse, 4003 Tunisia of Sousse, GREENS-ISSAT, Cité Ettafala, Ibn Khaldoun, Sousse 4003, Tunisia
| | - Malak Talbi
- Professorship Measurement and Sensor Technology, Chemnitz University of Technology, 09111 Chemnitz, Germany; (S.N.); (M.T.); (A.B.); (A.A.); (A.A.-H.)
- NANOMISENE Lab, LR16CRMN01, Centre for Research on Microelectronics and Nanotechnology of Sousse, Technopole of Sousse B.P. 334, Sahloul, Sousse 4034, Tunisia;
- Higher Institute of Applied Sciences and Technology of Sousse, University of Sousse, 4003 Tunisia of Sousse, GREENS-ISSAT, Cité Ettafala, Ibn Khaldoun, Sousse 4003, Tunisia
| | - Amina Brahem
- Professorship Measurement and Sensor Technology, Chemnitz University of Technology, 09111 Chemnitz, Germany; (S.N.); (M.T.); (A.B.); (A.A.); (A.A.-H.)
- NANOMISENE Lab, LR16CRMN01, Centre for Research on Microelectronics and Nanotechnology of Sousse, Technopole of Sousse B.P. 334, Sahloul, Sousse 4034, Tunisia;
- Higher Institute of Applied Sciences and Technology of Sousse, University of Sousse, 4003 Tunisia of Sousse, GREENS-ISSAT, Cité Ettafala, Ibn Khaldoun, Sousse 4003, Tunisia
| | - Anurag Adiraju
- Professorship Measurement and Sensor Technology, Chemnitz University of Technology, 09111 Chemnitz, Germany; (S.N.); (M.T.); (A.B.); (A.A.); (A.A.-H.)
| | - Evgeniya Sheremet
- Research School of Physics, Tomsk Polytechnic University, Tomsk 634050, Russia;
| | - Raul D. Rodriguez
- Research School of Chemical and Biomedical Technologies, Tomsk Polytechnic University, Tomsk 634050, Russia;
| | - Mounir Ben Ali
- NANOMISENE Lab, LR16CRMN01, Centre for Research on Microelectronics and Nanotechnology of Sousse, Technopole of Sousse B.P. 334, Sahloul, Sousse 4034, Tunisia;
- Higher Institute of Applied Sciences and Technology of Sousse, University of Sousse, 4003 Tunisia of Sousse, GREENS-ISSAT, Cité Ettafala, Ibn Khaldoun, Sousse 4003, Tunisia
| | - Ammar Al-Hamry
- Professorship Measurement and Sensor Technology, Chemnitz University of Technology, 09111 Chemnitz, Germany; (S.N.); (M.T.); (A.B.); (A.A.); (A.A.-H.)
| |
Collapse
|
6
|
İncebay H, Saylakci R. Voltammetric Determination of Neotame by Using Chitosan/Nickelnanoparticles/Multi Walled Carbon Nanotubes Biocomposite as a Modifier. ELECTROANAL 2021. [DOI: 10.1002/elan.202100021] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- Hilal İncebay
- Nevsehir Hacı Bektas Veli University Faculty of Arts and Sciences Department of Molecular Biology and Genetics Nevsehir Turkey
| | - Rumeysa Saylakci
- Nevsehir Hacı Bektas Veli University Faculty of Arts and Sciences Department of Molecular Biology and Genetics Nevsehir Turkey
| |
Collapse
|
7
|
Fadillah G, Triana S, Chasanah U, Saleh TA. Titania-nanorods modified carbon paste electrode for the sensitive voltammetric determination of BPA in exposed bottled water. SENSING AND BIO-SENSING RESEARCH 2020. [DOI: 10.1016/j.sbsr.2020.100391] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
|
8
|
Karimi F, Zakariae N, Esmaeili R, Alizadeh M, Tamadon AM. Carbon Nanotubes for Amplification of Electrochemical Signal in Drug and Food Analysis; A Mini Review. ACTA ACUST UNITED AC 2020. [DOI: 10.2174/2212711906666200224110404] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Background:
Electrochemical sensors are widely used for the determination of drugs and
food compounds. In recent years, the amplification of electrochemical signals with nanomaterials, especially
Carbon Nanotubes (CNTs) has created a major revolution in electrochemistry.
Objective:
The present mini-review paper focused on studying the role of CNTs as conductive mediators
for the fabrication of highly sensitive electrochemical sensors. CNTs, with high conductivity and
good ability for modification with other materials, are interesting candidates for improving the sensitivity
of electrochemical sensors. CNTs or their derivatives are suggested for different applications in
electrochemistry and especially analytical biosensors. This review is aimed to discuss the conductivity
feature of CNTs in electrochemical sensors.
Collapse
Affiliation(s)
- Fatemeh Karimi
- Department of Chemical Engineering, Quchan University of Technology, Quchan, Iran
| | - Nilofar Zakariae
- Nursing Medical-Surgical Group, Shahid Beheshti University of Medical Science, Tehran, Iran
| | - Roghayeh Esmaeili
- Nursing Medical-Surgical Group, Shahid Beheshti University of Medical Science, Tehran, Iran
| | - Marzieh Alizadeh
- Center for Nanotechnology in Drug Delivery, School of Pharmacy, Shiraz University of Medical Sciences, Shiraz, PO Box 71345-1583, Iran
| | - Ali-Mohammad Tamadon
- Center for Nanotechnology in Drug Delivery, School of Pharmacy, Shiraz University of Medical Sciences, Shiraz, PO Box 71345-1583, Iran
| |
Collapse
|
9
|
Tajik S, Beitollahi H, Nejad FG, Zhang K, Le QV, Jang HW, Kim SY, Shokouhimehr M. Recent Advances in Electrochemical Sensors and Biosensors for Detecting Bisphenol A. SENSORS (BASEL, SWITZERLAND) 2020; 20:E3364. [PMID: 32545829 PMCID: PMC7349560 DOI: 10.3390/s20123364] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/12/2020] [Revised: 06/01/2020] [Accepted: 06/02/2020] [Indexed: 12/15/2022]
Abstract
In recent years, several studies have focused on environmental pollutants. Bisphenol A (BPA) is one prominent industrial raw material, and its extensive utilization and release into the environment constitute an environmental hazard. BPA is considered as to be an endocrine disruptor which mimics hormones, and has a direct relationship to the development and growth of animal and human reproductive systems. Moreover, intensive exposure to the compound is related to prostate and breast cancer, infertility, obesity, and diabetes. Hence, accurate and reliable determination techniques are crucial for preventing human exposure to BPA. Experts in the field have published general electrochemical procedures for detecting BPA. The present timely review critically evaluates diverse chemically modified electrodes using various substances that have been reported in numerous studies in the recent decade for use in electrochemical sensors and biosensors to detect BPA. Additionally, the essential contributions of these substances for the design of electrochemical sensors are presented. It has been predicted that chemically modified electrode-based sensing systems will be possible options for the monitoring of detrimental pollutants.
Collapse
Affiliation(s)
- Somayeh Tajik
- Research Center for Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman 7616913555, Iran;
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman 76315117, Iran;
| | - Fariba Garkani Nejad
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman 76315117, Iran;
| | - Kaiqiang Zhang
- Jiangsu Key Laboratory of Advanced Organic Materials, Key Laboratory of Mesoscopic Chemistry of MOE, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China;
| | - Quyet Van Le
- Institute of Research and Development, Duy Tan University, Da Nang 550000, Vietnam
| | - Ho Won Jang
- Research Institute of Advanced Materials, Department of Materials Science and Engineering, Seoul National University, Seoul 08826, Korea;
| | - Soo Young Kim
- Department of Materials Science and Engineering, Korea University, 145, Anam-roSeongbuk-gu, Seoul 02841, Korea
| | - Mohammadreza Shokouhimehr
- Research Institute of Advanced Materials, Department of Materials Science and Engineering, Seoul National University, Seoul 08826, Korea;
| |
Collapse
|
10
|
Gugoasa LA, Stefan-van Staden RI, van Staden JF, Coroș M, Pruneanu S. Electrochemical Determination of Bisphenol A in Saliva by a Novel Three-Dimensional (3D) Printed Gold-Reduced Graphene Oxide (rGO) Composite Paste Electrode. ANAL LETT 2019. [DOI: 10.1080/00032719.2019.1620262] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Affiliation(s)
- Livia Alexandra Gugoasa
- Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, Bucharest-6, Romania
| | - Raluca-Ioana Stefan-van Staden
- Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, Bucharest-6, Romania
| | - Jacobus Frederick van Staden
- Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, Bucharest-6, Romania
| | - Maria Coroș
- National Institute for Research and Development of Isotopic and Molecular Technologies, Cluj-Napoca, Romania
| | - Stela Pruneanu
- National Institute for Research and Development of Isotopic and Molecular Technologies, Cluj-Napoca, Romania
| |
Collapse
|
11
|
Development of a tyrosinase-based biosensor for bisphenol A detection using gold leaf–like microstructures. J Solid State Electrochem 2019. [DOI: 10.1007/s10008-019-04252-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
12
|
Mohammad Ali Kamyabi, Nasim Hajari. Easy Activation of Pencil Graphite Electrode as Sensing Platform for Determination of Bisphenol A. JOURNAL OF ANALYTICAL CHEMISTRY 2019. [DOI: 10.1134/s1061934819030109] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
13
|
Sidwaba U, Ntshongontshi N, Feleni U, Wilson L, Waryo T, Iwuoha EI. Manganese Peroxidase-Based Electro-Oxidation of Bisphenol A at Hydrogellic Polyaniline-Titania Nanocomposite-Modified Glassy Carbon Electrode. Electrocatalysis (N Y) 2019. [DOI: 10.1007/s12678-019-0510-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
14
|
Ulubay Karabiberoğlu Ş. Sensitive Voltammetric Determination of Bisphenol A Based on a Glassy Carbon Electrode Modified with Copper Oxide-Zinc Oxide Decorated on Graphene Oxide. ELECTROANAL 2018. [DOI: 10.1002/elan.201800415] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
15
|
Beitollahi H, Movahedifar F, Tajik S, Jahani S. A Review on the Effects of Introducing CNTs in the Modification Process of Electrochemical Sensors. ELECTROANAL 2018. [DOI: 10.1002/elan.201800370] [Citation(s) in RCA: 74] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Hadi Beitollahi
- Environment DepartmentInstitute of Science and High Technology and EnvironmentalSciencesGraduate University of Advanced Technology Kerman Iran
| | - Fahimeh Movahedifar
- Environment DepartmentInstitute of Science and High Technology and EnvironmentalSciencesGraduate University of Advanced Technology Kerman Iran
| | - Somayeh Tajik
- NanoBioElectrochemistry Research CenterBam University of Medical Sciences Bam Iran
| | - Shohreh Jahani
- NanoBioElectrochemistry Research CenterBam University of Medical Sciences Bam Iran
| |
Collapse
|
16
|
Gholivand MB, Akbari A. A novel and high sensitive MWCNTs-nickel carbide/hollow fiber-pencil graphite modified electrode for in situ ultra-trace analysis of bisphenol A. J Electroanal Chem (Lausanne) 2018. [DOI: 10.1016/j.jelechem.2018.03.065] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
17
|
Pei DN, Zhang AY, Pan XQ, Si Y, Yu HQ. Electrochemical Sensing of Bisphenol A on Facet-Tailored TiO2 Single Crystals Engineered by Inorganic-Framework Molecular Imprinting Sites. Anal Chem 2018; 90:3165-3173. [DOI: 10.1021/acs.analchem.7b04466] [Citation(s) in RCA: 53] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Affiliation(s)
- Dan-Ni Pei
- CAS Key Laboratory of Urban Pollutant Conversion, Department of Chemistry, University of Science & Technology of China, Hefei, 230026, China
| | - Ai-Yong Zhang
- CAS Key Laboratory of Urban Pollutant Conversion, Department of Chemistry, University of Science & Technology of China, Hefei, 230026, China
- Department of Municipal Engineering, Hefei University of Technology, Hefei, 230009, China
| | - Xiao-Qiang Pan
- CAS Key Laboratory of Urban Pollutant Conversion, Department of Chemistry, University of Science & Technology of China, Hefei, 230026, China
| | - Yang Si
- CAS Key Laboratory of Urban Pollutant Conversion, Department of Chemistry, University of Science & Technology of China, Hefei, 230026, China
| | - Han-Qing Yu
- CAS Key Laboratory of Urban Pollutant Conversion, Department of Chemistry, University of Science & Technology of China, Hefei, 230026, China
| |
Collapse
|
18
|
Li Y, Wang H, Yan B, Zhang H. An electrochemical sensor for the determination of bisphenol A using glassy carbon electrode modified with reduced graphene oxide-silver/poly-l-lysine nanocomposites. J Electroanal Chem (Lausanne) 2017. [DOI: 10.1016/j.jelechem.2017.10.022] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
19
|
Advances in sensing and biosensing of bisphenols: A review. Anal Chim Acta 2017; 998:1-27. [PMID: 29153082 DOI: 10.1016/j.aca.2017.09.048] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2017] [Revised: 09/22/2017] [Accepted: 09/23/2017] [Indexed: 12/19/2022]
Abstract
Bisphenols (BPs) are well known endocrine disrupting chemicals (EDCs) that cause adverse effects on the environment, biotic life and human health. BPs have been studied extensively because of an increasing concern for the safety of the environment and for human health. They are major raw materials for manufacturing polycarbonates, thermal papers and epoxy resins and are considered hazardous environmental contaminants. A vast array of sensors and biosensors have been developed for the sensitive screening of BPs based on carbon nanomaterials (carbon nanotubes, fullerenes, graphene and graphene oxide), quantum dots, metal and metal oxide nanocomposites, polymer nanocomposites, metal organic frameworks, ionic liquids and molecularly imprinted polymers. This review is devoted mainly to a variety of sensitive, selective and reliable sensing and biosensing methods for the detection of BPs using electrochemistry, fluorescence, colorimetry, surface plasmon resonance, luminescence, ELISAs, circular dichroism, resonance Rayleigh scattering and adsorption techniques in plastic products, food samples, food packaging, industrial wastes, pharmaceutical products, human body fluids and many other matrices. It summarizes the advances in sensing and biosensing methods for the detection of BPs since 2010. Furthermore, the article discusses challenges and future perspectives in the development of novel sensing methods for the detection of BP analogs.
Collapse
|
20
|
Varmira K, Saed-Mocheshi M, Jalalvand AR. Electrochemical sensing and bio-sensing of bisphenol A and detection of its damage to DNA: A comprehensive review. SENSING AND BIO-SENSING RESEARCH 2017. [DOI: 10.1016/j.sbsr.2017.07.002] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
21
|
Ławrywianiec M, Smajdor J, Paczosa-Bator B, Piech R. High Sensitive Method for Determination of the Toxic Bisphenol A in Food/Beverage Packaging and Thermal Paper Using Glassy Carbon Electrode Modified with Carbon Black Nanoparticles. FOOD ANAL METHOD 2017. [DOI: 10.1007/s12161-017-0945-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
22
|
ALTUNAY NAİL, YILDIRIM E, GÜRKAN R. Determination of bisphenol A in plastic bottle packaging beverage samples using ultrasonic-assisted extraction and flame atomic absorption spectrometry. JOURNAL OF THE TURKISH CHEMICAL SOCIETY, SECTION A: CHEMISTRY 2017. [DOI: 10.18596/jotcsa.288389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
|
23
|
A New Ultrasonic Thermostatic-Assisted Cloud Point Extraction/Spectrophotometric Method for the Preconcentration and Determination of Bisphenol A in Food, Milk, and Water Samples in Contact with Plastic Products. FOOD ANAL METHOD 2016. [DOI: 10.1007/s12161-016-0737-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
24
|
Pogacean F, Biris AR, Socaci C, Coros M, Magerusan L, Rosu MC, Lazar MD, Borodi G, Pruneanu S. Graphene-bimetallic nanoparticle composites with enhanced electro-catalytic detection of bisphenol A. NANOTECHNOLOGY 2016; 27:484001. [PMID: 27804923 DOI: 10.1088/0957-4484/27/48/484001] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
This study brings for the first time novel knowledge about the synthesis by catalytic chemical vapor deposition with induction heating of graphene-bimetallic nanoparticle composites (Gr-AuCu and Gr-AgCu) and their morphological and structural characterization by transmission electron microscopy, Raman spectroscopy, and x-ray powder diffraction. Gold electrodes modified with the obtained materials exhibit an enhanced electro-catalytic effect towards one of the most encountered estrogenic disruptive chemicals, bisphenol A (BPA). The BPA behavior in varying pH solutions was investigated using the electrochemical quartz crystal microbalance, which allowed the accurate determination of the number of molecules involved in the oxidation process. The modified electrodes promote the oxidation of BPA at significantly lower potentials (0.66 V) compared to bare gold (0.78 V). In addition, the peak current density recorded with such electrodes greatly exceeded that obtained with bare gold (e.g. one order of magnitude larger, for a Au/Gr-AgCu electrode). The two modified electrodes have low detection limits, of 1.31 × 10-6 M and 1.91 × 10-6 M for Au/Gr-AgCu and Au/Gr-AuCu, respectively. The bare gold electrode has a higher detection limit of 5.1 × 10-6 M. The effect of interfering species (e.g. catechol and 3-nitrophenol) was also investigated. Their presence influenced not only the BPA peak potential, but also the peak current. With both modified electrodes, no peak currents were recorded below 3 × 10-5 M BPA.
Collapse
Affiliation(s)
- Florina Pogacean
- National Institute for Research and Development of Isotopic and Molecular Technologies, Donat Street, No. 67-103, RO-400293, Cluj-Napoca, Romania
| | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Li J, Kim BK, Wang KK, Im JE, Choi HN, Kim DH, Cho SI, Lee WY, Kim YR. Sensing Estrogen with Electrochemical Impedance Spectroscopy. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY 2016; 2016:9081375. [PMID: 27803838 PMCID: PMC5075617 DOI: 10.1155/2016/9081375] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Revised: 08/11/2016] [Accepted: 09/04/2016] [Indexed: 06/06/2023]
Abstract
This study demonstrates the application feasibility of electrochemical impedance spectroscopy (EIS) in measuring estrogen (17β-estradiol) in gas phase. The present biosensor gives a linear response (R2 = 0.999) for 17β-estradiol vapor concentration from 3.7 ng/L to 3.7 × 10-4 ng/L with a limit of detection (3.7 × 10-4 ng/L). The results show that the fabricated biosensor demonstrates better detection limit of 17β-estradiol in gas phase than the previous report with GC-MS method. This estrogen biosensor has many potential applications for on-site detection of a variety of endocrine disrupting compounds (EDCs) in the gas phase.
Collapse
Affiliation(s)
- Jing Li
- Department of Chemistry, Yonsei University, Seoul 120-749, Republic of Korea
| | - Byung Kun Kim
- Department of Chemistry, Yonsei University, Seoul 120-749, Republic of Korea
| | - Kang-Kyun Wang
- Department of Chemistry, Yonsei University, Seoul 120-749, Republic of Korea
| | - Ji-Eun Im
- Department of Chemistry, Yonsei University, Seoul 120-749, Republic of Korea
| | - Han Nim Choi
- Department of Chemistry, Yonsei University, Seoul 120-749, Republic of Korea
| | - Dong-Hwan Kim
- Department of Chemistry, Yonsei University, Seoul 120-749, Republic of Korea
| | - Seong In Cho
- Department of Biosystems and Biomaterials Science and Engineering, Seoul National University, Seoul 151-921, Republic of Korea
| | - Won-Yong Lee
- Department of Chemistry, Yonsei University, Seoul 120-749, Republic of Korea
| | - Yong-Rok Kim
- Department of Chemistry, Yonsei University, Seoul 120-749, Republic of Korea
| |
Collapse
|
26
|
Liu Y, Zhang X, Yang J, Xiong E, Zhang X, Chen J. Sensitive detection of bisphenol A based on a ratiometric electrochemical aptasensor. CAN J CHEM 2016. [DOI: 10.1139/cjc-2015-0533] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A new ratiometric electrochemical aptasensor has been developed for highly sensitive and selective detection of bisphenol A (BPA). The double-stranded DNA (dsDNA), consisting of the BPA aptamer (DNA1) and methylene blue (MB)-labeled complementary DNA (cDNA), was immobilized on a gold nanoparticle (AuNP) modified glassy carbon (GC) electrode. In the presence of BPA, the specific BPA–aptamer interaction drove the release of the MB-labeled cDNA from the electrode surface. As a result, the oxidation peak current of MB (IMB) decreased and that of BPA (IBPA) increased. The peak current ratio (IBPA/IMB) of BPA and MB was linear with the concentration of BPA in the range from 1 to 100 pmol/L with a detection limit of 0.6 pmol/L. The detection limit is much lower than that obtained by most of the reported electrochemical methods. On the other hand, the developed aptasensor possesses good selectivity, reproducibility, and stability, and the related sensing structure is very simple, showing promising practical applications in BPA assays.
Collapse
Affiliation(s)
- Yunqing Liu
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P.R. China
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P.R. China
| | - Xia Zhang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P.R. China
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P.R. China
| | - Junshuai Yang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P.R. China
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P.R. China
| | - Erhu Xiong
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P.R. China
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P.R. China
| | - Xiaohua Zhang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P.R. China
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P.R. China
| | - Jinhua Chen
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P.R. China
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P.R. China
| |
Collapse
|
27
|
GC electrode modified with carbon nanotubes and NiO for the simultaneous determination of bisphenol A, hydroquinone and catechol. Electrochim Acta 2016. [DOI: 10.1016/j.electacta.2016.02.174] [Citation(s) in RCA: 81] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
28
|
Liquid phase determination of bisphenol A in food samples using novel nanostructure ionic liquid modified sensor. J Mol Liq 2016. [DOI: 10.1016/j.molliq.2015.12.003] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
29
|
Jang J, Kim DH, Lee WY. Electrochemical Determination of Bisphenol A by Single-Walled Carbon Nanotube Composite Glassy Carbon Electrode. ANAL LETT 2016. [DOI: 10.1080/00032719.2015.1134560] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
30
|
Wang Y, Liu G, Hou X, Huang Y, Li C, Wu K. Assembling gold nanorods on a poly-cysteine modified glassy carbon electrode strongly enhance the electrochemical reponse to tetrabromobisphenol A. Mikrochim Acta 2015. [DOI: 10.1007/s00604-015-1708-0] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
31
|
Scientific Opinion on the risks to public health related to the presence of bisphenol A (BPA) in foodstuffs. EFSA J 2015. [DOI: 10.2903/j.efsa.2015.3978] [Citation(s) in RCA: 528] [Impact Index Per Article: 58.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
|
32
|
Li J, Feng H, Feng Y, Liu J, Liu Y, Jiang J, Qian D. A glassy carbon electrode modified with β-cyclodextin, multiwalled carbon nanotubes and graphene oxide for sensitive determination of 1,3-dinitrobenzene. Mikrochim Acta 2014. [DOI: 10.1007/s00604-014-1271-0] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
33
|
Zhuang Y, Zhou M, Gu J, Li X. Spectrophotometric and high performance liquid chromatographic methods for sensitive determination of bisphenol A. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2014; 122:153-157. [PMID: 24309176 DOI: 10.1016/j.saa.2013.11.015] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2013] [Revised: 10/30/2013] [Accepted: 11/05/2013] [Indexed: 06/02/2023]
Abstract
A new spectrophotometric method for the determination of trace amounts of bisphenol A based on a diazotization-coupling reaction was developed. In acidic solution, clenbuterol was first diazotized with sodium nitrite, then coupled with bisphenol A to from an azo-compound [I] in NH3-NH4Cl buffer, which shows a maximum absorption at 410 nm. The effects of the amount of sodium nitrite, diazo reaction time, the amount of clenbuterol, coupling reaction time and coupling reaction temperature have been examined. Under the optional conditions, the determination of the linear range of bisphenol A is 0.24-8.4 μg/mL, correlation coefficient is 0.9905 and detection limit of this method is 0.15 μg/mL. The spectrophotometric method is simple, rapid, high sensitivity with better accuracy. High performance liquid chromatography (HPLC) technique combined with this new spectrophotometric method has been also developed for the measurement of bisphenol A. The analysis was achieved on a C18 column using water and methanol as a mobile phase and the detection was done spectrophotometrically at 410 nm. These reported methods were applied to the determination of bisphenol A in hot water in contact with commercially available table-water bottle samples.
Collapse
Affiliation(s)
- Yafeng Zhuang
- Department of Chemistry, School of Science, Changzhou Institute of Technology, Changzhou, Jiangsu 213022, PR China.
| | - Meng Zhou
- Department of Chemistry, School of Science, Changzhou Institute of Technology, Changzhou, Jiangsu 213022, PR China
| | - Jia Gu
- Department of Chemistry, School of Science, Changzhou Institute of Technology, Changzhou, Jiangsu 213022, PR China
| | - Xiangmei Li
- Department of Chemistry, School of Science, Changzhou Institute of Technology, Changzhou, Jiangsu 213022, PR China
| |
Collapse
|
34
|
Ma M, Tu X, Zhan G, Li C, Zhang S. Electrochemical sensor for bisphenol A based on a nanoporous polymerized ionic liquid interface. Mikrochim Acta 2014. [DOI: 10.1007/s00604-013-1151-z] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
35
|
Wu C, Cheng Q, Li L, Chen J, Wu K. Synergetic signal amplification of graphene-Fe2O3 hybrid and hexadecyltrimethylammonium bromide as an ultrasensitive detection platform for bisphenol A. Electrochim Acta 2014. [DOI: 10.1016/j.electacta.2013.10.188] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
36
|
Deng P, Xu Z, Kuang Y. Electrochemically reduced graphene oxide modified acetylene black paste electrode for the sensitive determination of bisphenol A. J Electroanal Chem (Lausanne) 2013. [DOI: 10.1016/j.jelechem.2013.08.020] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
37
|
Sensitive detection of enteropathogenic E. coli using a bfpA gene-based electrochemical sensor. Mikrochim Acta 2013. [DOI: 10.1007/s00604-013-1061-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
38
|
Biosensor for bisphenol A leaching from baby bottles using a glassy carbon electrode modified with DNA and single walled carbon nanotubes. Mikrochim Acta 2013. [DOI: 10.1007/s00604-013-1025-4] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
39
|
Deng P, Xu Z, Li J, Kuang Y. Acetylene black paste electrode modified with a molecularly imprinted chitosan film for the detection of bisphenol A. Mikrochim Acta 2013. [DOI: 10.1007/s00604-013-1001-z] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
40
|
Kim BK, Kim JY, Kim DH, Choi HN, Lee WY. Electrochemical Determination of Bisphenol A at Carbon Nanotube-Doped Titania-Nafion Composite Modified Electrode. B KOREAN CHEM SOC 2013. [DOI: 10.5012/bkcs.2013.34.4.1065] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
41
|
Qurashi A, Rather JA, De Wael K, Merzougui B, Tabet N, Faiz M. Rapid microwave synthesis of high aspect-ratio ZnO nanotetrapods for swift bisphenol A detection. Analyst 2013; 138:4764-8. [DOI: 10.1039/c3an00336a] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
42
|
Electrochemical tyrosine sensor based on a glassy carbon electrode modified with a nanohybrid made from graphene oxide and multiwalled carbon nanotubes. Mikrochim Acta 2012. [DOI: 10.1007/s00604-012-0905-3] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
43
|
Abstract
The use of an exfoliated graphite (EG) electrode in the square wave voltammetric detection of bisphenol A (a model phenolic pollutant) in water, whereby the phenolic electrode fouling challenge is mitigated, is described. The oxidation peak of BPA was observed at about 0.45 V in phosphate buffer solution at pH 10. The current response exhibited a linear relationship with the concentration over a range from 1.56 μM–50 μM. The detection limit was calculated to be 0.76 μM. The EG electrode surface was renewed after each measurement with excellent reproducibility. A real sample application was also investigated.
Collapse
|
44
|
Li J, Kuang D, Feng Y, Zhang F, Xu Z, Liu M. A Novel Electrochemical Method for Sensitive Detection of Melamine in Infant Formula and Milk using Ascorbic Acid as Recognition Element. B KOREAN CHEM SOC 2012. [DOI: 10.5012/bkcs.2012.33.8.2499] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
45
|
Gao Y, Cao Y, Yang D, Luo X, Tang Y, Li H. Sensitivity and selectivity determination of bisphenol A using SWCNT-CD conjugate modified glassy carbon electrode. JOURNAL OF HAZARDOUS MATERIALS 2012; 199-200:111-118. [PMID: 22100222 DOI: 10.1016/j.jhazmat.2011.10.066] [Citation(s) in RCA: 75] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2011] [Revised: 10/18/2011] [Accepted: 10/22/2011] [Indexed: 05/31/2023]
Abstract
In this study, we demonstrated a highly sensitive electrochemical sensor for the determination of bisphenol A (BPA) in aqueous solution by using single-walled carbon nanotubes (SWCNTs)/β-cyclodextrin (β-CD) conjugate (SWCNT-CD) modified glassy carbon electrode (GCE). The cyclic voltammetry results show that the modified GCE exhibits strong catalytic activity toward the oxidation of BPA with a well-defined cyclic voltammetric peak at 0.543 V. The response current exhibits a linear range between 10.8 nM and 18.5 μM with a high sensitivity (1256 μA mM(-1)). The detection limit of BPA is 1.0 nM (S/N=3). The enhanced performance of the fabricated sensor can be attributed to the combination of the excellent electrocatalytic properties of SWCNTs and the molecular recognition ability of β-CD. The sensor was successfully applied to determine BPA leached from real plastic samples with good recovery, ranging from 95% to 103%.
Collapse
Affiliation(s)
- Yong Gao
- College of Chemistry, Xiangtan University, Xiangtan 411105, Hunan Province, PR China
| | | | | | | | | | | |
Collapse
|
46
|
Amperometric sensor for detection of bisphenol A using a pencil graphite electrode modified with polyaniline nanorods and multiwalled carbon nanotubes. Mikrochim Acta 2011. [DOI: 10.1007/s00604-011-0698-9] [Citation(s) in RCA: 60] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
47
|
Glucose biosensor based on glucose oxidase immobilized on a nanofilm composed of mesoporous hydroxyapatite, titanium dioxide, and modified with multi-walled carbon nanotubes. Mikrochim Acta 2011. [DOI: 10.1007/s00604-011-0693-1] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
48
|
Biosensor based on a glassy carbon electrode modified with tyrosinase immmobilized on multiwalled carbon nanotubes. Mikrochim Acta 2011. [DOI: 10.1007/s00604-011-0616-1] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|