1
|
Zhang Y, Ren D, Shi Y, Yuan R, Ye H, Yin XB, Chi H. A smartphone sensing fluorescent detection of mercury ion based on silicon quantum dots in environment water. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2025; 325:125135. [PMID: 39299073 DOI: 10.1016/j.saa.2024.125135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Revised: 08/28/2024] [Accepted: 09/11/2024] [Indexed: 09/22/2024]
Abstract
Mercury ion (Hg2+) pose a significant hazard to the natural environment. Conventional techniques like Inductively coupled plasma mass spectrometry, X-ray absorption spectroscopy, among others, pose some disadvantages as they demand a lot of money, need trained employees, and cannot provide on-site detection in real-time. A smartphone sensing technique based on silicon quantum dots (Si-QDs) was presented to detect Hg2+ in the environment without the usage of sophisticated equipment. Meanwhile, the technology was built by utilizing a smartphone to capture gray values of fluorescent images of the Si-QDs-Hg2+ system. Microwave-assisted Si-QDs with tiny particle size, high fluorescence, and good optical stability were created. The fluorescence of the Si-QDs was gradually quenched by raising the Hg2+ concentration from 0.5 μmol/L to 5.0 μmol/L for fluorescent detection with a detection limit of 28 nmol/L. The 94.8-97.1 % recovery demonstrated the viability of the Si-QDs approach for detecting Hg2+. Meanwhile, a smartphone sensing strategy was built by recording the gray value of the fluorescent images of the Si-QDs-Hg2+ systems using a smartphone, and the detection limit of the established approach was 3 nmol/L. The accuracy and reliability of the smartphone strategy were verified with the recovery rates of 80.3-92.5 % in tap water and 87.6-109 % in river water. Electron transfer quenching mechanism between Si-QDs and Hg2+ was evidenced by ultraviolet-visible spectroscopy, fluorescent decay curves, cyclic voltammetry, and Zeta potential. Finally, the suggested approach was used to detect Hg2+ in water samples from various environments.
Collapse
Affiliation(s)
- Yuanxing Zhang
- Laboratory of Aquatic Product Quality, Safety and Processing, Key Laboratory of Oceanic and Polar Fisheries, Ministry of Agriculture and Rural Affairs, East China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Shanghai 200090, PR China; College of Food Science and Engineering, Dalian Ocean University, Dalian 116023, PR China
| | - Dandan Ren
- College of Food Science and Engineering, Dalian Ocean University, Dalian 116023, PR China
| | - Yongfu Shi
- Laboratory of Aquatic Product Quality, Safety and Processing, Key Laboratory of Oceanic and Polar Fisheries, Ministry of Agriculture and Rural Affairs, East China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Shanghai 200090, PR China
| | - Rui Yuan
- Laboratory of Aquatic Product Quality, Safety and Processing, Key Laboratory of Oceanic and Polar Fisheries, Ministry of Agriculture and Rural Affairs, East China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Shanghai 200090, PR China
| | - Hongli Ye
- Laboratory of Aquatic Product Quality, Safety and Processing, Key Laboratory of Oceanic and Polar Fisheries, Ministry of Agriculture and Rural Affairs, East China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Shanghai 200090, PR China; Key Laboratory of Control of Safety and Quality for Aquatic Product, Ministry of Agriculture and Rural Affairs, Beijing 100141, PR China.
| | - Xue-Bo Yin
- Institute for Frontier Medical Technology, College of Chemistry and Chemical Engineering, Shanghai University of Engineering Science, Shanghai 201620, PR China.
| | - Hai Chi
- Laboratory of Aquatic Product Quality, Safety and Processing, Key Laboratory of Oceanic and Polar Fisheries, Ministry of Agriculture and Rural Affairs, East China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Shanghai 200090, PR China; College of Food Science and Engineering, Dalian Ocean University, Dalian 116023, PR China.
| |
Collapse
|
2
|
Kelíšková P, Matvieiev O, Jiroušková E, Sokolová R, Janíková L, Behúl M, Šelešovská R. Voltammetric and flow amperometric determination of drug guaifenesin in pharmaceutical and biological samples using screen-printed sensor with boron doped diamond electrode. Talanta 2025; 281:126809. [PMID: 39276571 DOI: 10.1016/j.talanta.2024.126809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2024] [Revised: 08/06/2024] [Accepted: 09/03/2024] [Indexed: 09/17/2024]
Abstract
New voltammetric and flow amperometric methods for the determination of guaifenesin (GFE) using a perspective screen-printed sensor (SPE) with boron-doped diamond electrode (BDDE) were developed. The electrochemical oxidation of GFE was studied on the surface of the oxygen-terminated BDDE of the sensor. The GFE provided two irreversible anodic signals at a potential of 1.0 and 1.1 V (vs. Ag|AgCl|KCl sat.) in Britton-Robinson buffer (pH 2), which was chosen as the supporting electrolyte for all measurements. First, a voltammetric method based on differential pulse voltammetry was developed and a low detection limit (LOD = 41 nmol L-1), a wide linear dynamic range (LDR = 0.1-155 μmol L-1), and a good recovery in the analysis of model and pharmaceutical samples (RSD <3.0 %) were obtained. In addition, this sensor demonstrated excellent sensitivity and reproducibility in the analysis of biological samples (RSD <3.2 %), where the analysis took place in a drop of serum (50 μL) without pretreatment and additional electrolyte. Subsequently, SP/BDDE was incorporated into a flow-through 3D printed electrochemical cell and a flow injection analysis method with electrochemical detection (FIA-ED) was developed, resulting in excellent analytical parameters (LOD = 86 nmol L-1, LDR = 0.1-50 μmol L-1). Moreover, the mechanism of electrochemical oxidation of GFE was proposed based on calculations of HOMO spatial distribution and spectroelectrochemical measurements focused on IR identification of intermediates and products.
Collapse
Affiliation(s)
- Pavlína Kelíšková
- University of Pardubice, Faculty of Chemical Technology, Institute of Environmental and Chemical Engineering, Studentská 573, 532 10, Pardubice, Czech Republic
| | - Oleksandr Matvieiev
- University of Pardubice, Faculty of Chemical Technology, Institute of Environmental and Chemical Engineering, Studentská 573, 532 10, Pardubice, Czech Republic.
| | - Eliška Jiroušková
- J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences, Dolejškova 3, 18223, Prague, Czech Republic
| | - Romana Sokolová
- J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences, Dolejškova 3, 18223, Prague, Czech Republic.
| | - Lenka Janíková
- University of Pardubice, Faculty of Chemical Technology, Institute of Environmental and Chemical Engineering, Studentská 573, 532 10, Pardubice, Czech Republic
| | - Miroslav Behúl
- Slovak University of Technology in Bratislava, Faculty of Electrical Engineering and Information Technology, Institute of Electronics and Photonics, Ilkovičova 3, 812 19, Bratislava, Slovak Republic
| | - Renáta Šelešovská
- University of Pardubice, Faculty of Chemical Technology, Institute of Environmental and Chemical Engineering, Studentská 573, 532 10, Pardubice, Czech Republic
| |
Collapse
|
3
|
Thaweeskulchai T, Prempinij W, Schulte A. A 3D printed dual screen-printed electrode separation device for twin electrochemical mini-cell establishment. RSC Adv 2024; 14:30830-30835. [PMID: 39328873 PMCID: PMC11426311 DOI: 10.1039/d4ra05929h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2024] [Accepted: 09/10/2024] [Indexed: 09/28/2024] Open
Abstract
We describe a tiny 3D-printed polymethyl-methacrylate-based plastic sleeve that houses two disposable screen-printed electrodes (SPE) and enables each of the working electrodes (WEs) to work independently, on a different side of a thin barrier, in its own electrochemical (EC) mini-cell, while the SPE counter and reference units are shared for electroanalysis. Optical and EC performance tests proved that the plastic divider between WE1 and WE2 efficiently inhibited solution mixing between the mini-cells. The two neighboring, independently operating mini-cells enabled matched differential measurements in the same sample solution, a tactic designed for elimination of electrochemical interference in complex samples. In a proof-of-principle glucose biosensor trial, a glucose oxidase-modified WE2 and an unmodified WE1 delivered the EC data for the removal of anodic ascorbic acid (AA) interference simply by subtracting the WE1 (background) current from the analyte-specific WE2 current (from buffered sample solution supplemented with glucose/AA), at an anodic H2O2 detection potential of +1 V. The microfabricated SPE accessory is cheap and easy to make and use. For the many dual electrode SPE strips on the market for multiple analytical targets the new device widens the options for their exploitation in assays of biological and environmental samples with complex matrix compositions and significant risks of interference.
Collapse
Affiliation(s)
- Thana Thaweeskulchai
- School of Biomolecular Science and Engineering (BSE) of the Vidyasirimedhi Institute of Science and Technology (VISTEC) 21210 Rayong Thailand
| | - Waswan Prempinij
- School of Biomolecular Science and Engineering (BSE) of the Vidyasirimedhi Institute of Science and Technology (VISTEC) 21210 Rayong Thailand
| | - Albert Schulte
- School of Biomolecular Science and Engineering (BSE) of the Vidyasirimedhi Institute of Science and Technology (VISTEC) 21210 Rayong Thailand
| |
Collapse
|
4
|
Li Y, Wang Z, Chen X, Yi Z, Wang R. In situ deposition of bismuth on pre-anodized screen-printed electrode for sensitive determination of Cd 2+ in water and rice with a portable device. Sci Rep 2024; 14:18433. [PMID: 39117723 PMCID: PMC11310196 DOI: 10.1038/s41598-024-69626-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2024] [Accepted: 08/07/2024] [Indexed: 08/10/2024] Open
Abstract
Electrochemical detection is favorable for the rapid and sensitive determination of heavy metal cadmium. However, the detection sensitivity needs to be further improved, and a portable, low-cost device is needed for on-site detection. Herein, an in-situ bismuth modified pre-anodized screen-printed carbon electrode (SPCE) was developed for Cd2+ determination by square wave anodic stripping voltammetry (SWASV). The in-situ bismuth modification enhances the enrichment of Cd2+, and together with pre-anodization improve the electron transfer rate of electrode, thus enhancing the detection sensitivity. The electrode modification method combines pre-anodization and in-situ bismuth deposition, which is very easy and effective. Furthermore, a self-made PSoC Stat potentiostat coupled with a stirring device was fabricated for portable and low-cost electrochemical detection. After comprehensive optimization, the developed method can reach a testing time of 3 min, a detection limit of 3.55 μg/L, a linear range of 5-100 μg/L, and a recovery rate of 91.7-107.1% in water and rice samples for Cd2+ determination. Therefore, our method holds great promise for the rapid, sensitive and on-site determination of Cd2+ in food samples.
Collapse
Affiliation(s)
- Yongfang Li
- School of Food Science and Engineering, Foshan University, Foshan, 528231, China
| | - Zijun Wang
- School of Food Science and Engineering, Foshan University, Foshan, 528231, China
| | - Xuan Chen
- School of Food Science and Engineering, Foshan University, Foshan, 528231, China
| | - Zhijian Yi
- School of Food Science and Engineering, Foshan University, Foshan, 528231, China
| | - Rui Wang
- Human Phenome Institute, State Key Laboratory of Genetic Engineering, Fudan University, Shanghai, 200438, China.
- Center for Medical Research and Innovation, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, 200438, China.
- International Human Phenome Institutes, Shanghai, 200438, China.
| |
Collapse
|
5
|
Laschi S, Sfragano PS, Tadini-Buoninsegni F, Guigues N, Palchetti I. Development of a flow system for decentralized electrochemical analysis of heavy metals using screen-printed electrodes: the importance of sensor stability. Analyst 2024; 149:4239-4249. [PMID: 38887058 DOI: 10.1039/d4an00616j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/20/2024]
Abstract
Year after year, the need for decentralized tools to tackle the monitoring of heavy metal levels in the environment gradually increases. In this context, suitable electrochemical methodologies are widely established and particularly attractive for the production of low-cost miniaturized field-deployable analytical platforms. This work focused on the development of an automatable portable system based on square-wave anodic stripping voltammetry (SWASV) for the on-line detection of heavy metals. The surface of the sensors is appropriately modified and coupled with a fluidic system equipped with an ad-hoc designed flow cell. A custom software tool was introduced to handle the remote-controlled potentiostat and automate the various steps of the procedure, including stirring operations, cleaning phases, SWASV measurements, and data collection. After studying technical and analytical challenges, the final system developed was applied to the simultaneous detection of Cd(II), Pb(II), and Cu(II) in solution, achieving sub-ppb detection limits. Additionally, the practical applicability of the method was successfully applied to river water samples collected from the Loire basin in France.
Collapse
Affiliation(s)
- Serena Laschi
- Department of Chemistry "Ugo Schiff" (DICUS), Via della Lastruccia 3, 50019 Sesto Fiorentino, FI, Italy.
| | - Patrick Severin Sfragano
- Department of Chemistry "Ugo Schiff" (DICUS), Via della Lastruccia 3, 50019 Sesto Fiorentino, FI, Italy.
| | | | - Nathalie Guigues
- Laboratoire national de métrologie et d'essai (LNE), 1 rue Gaston Boissier, 75015 Paris, France
| | - Ilaria Palchetti
- Department of Chemistry "Ugo Schiff" (DICUS), Via della Lastruccia 3, 50019 Sesto Fiorentino, FI, Italy.
| |
Collapse
|
6
|
Hashem HM, Abdallah AB. A rational study of transduction mechanisms of different materials for all solid contact-ISEs. Sci Rep 2024; 14:5405. [PMID: 38443429 PMCID: PMC10914792 DOI: 10.1038/s41598-024-55729-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Accepted: 02/27/2024] [Indexed: 03/07/2024] Open
Abstract
The new era of solid contact ion selective electrodes (SC-ISEs) miniaturized design has received an extensive amount of concern. Because it eliminated the requirement for ongoing internal solution composition optimization and created a two-phase system with stronger detection limitations. Herein, the determination of venlafaxine HCl is based on a comparison study between different ion- to electron transduction materials (such as; multiwalled carbon nanotubes (MWCNTs), polyaniline (PANi), and ferrocene) and illustrating their mechanisms in their applied sensors. Their different electrochemical features (such as bulk resistance (Rb**), double-layer capacitance (Cdl), geometric capacitance (Cg), and specific capacitance (Cp)) were evaluated and discussed by using the Electrochemical Impedance Spectroscopy (EIS), Chronopotentiometry (CP), and Cyclic Voltammetry (CV) experiments. The results indicated that each transducer's influence on the proposed sensor's electrochemical characteristics is determined by their unique chemical and physical properties. The electrochemical features vary for different solid contact materials used in transduction mechanisms. The results confirm that the MWCNT sensor revealed the best electrochemical behavior with the potentiometric response of a near-Nernestian slope of 56.1 ± 0.8 mV/decade with detection limits of 3.8 × 10-6 mol/L (r2 = 0.999) and a low potential drift (∆E/∆t) of 34.6 µV/s. Also, the selectivity study was performed in the presence of different interfering species either in single or complex matrices. This demonstrates excellent selectivity, stability, conductivity, and reliability as a VEN-TPB ion pair sensor for accurately measuring VEN in its various formulations. The proposed method was compared to HPLC reported technique and confirmed no significant difference between them. So, the proposed sensors fulfill their solutions' demand features for VEN appraisal.
Collapse
Affiliation(s)
- Heba M Hashem
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Mansoura University, Mansoura, 35516, Egypt.
| | - A B Abdallah
- Chemistry Department, Faculty of Science, Mansoura University, Mansoura, 35516, Egypt
- Chemistry Department, Faculty of Science, New Mansoura University, New Mansoura, Egypt
| |
Collapse
|
7
|
Wroński M, Trawiński J, Skibiński R. Electrochemical Simulation of Phase I Hepatic Metabolism of Voriconazole Using a Screen-Printed Iron(II) Phthalocyanine Electrode. Pharmaceutics 2023; 15:2586. [PMID: 38004565 PMCID: PMC10674253 DOI: 10.3390/pharmaceutics15112586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 10/30/2023] [Accepted: 11/02/2023] [Indexed: 11/26/2023] Open
Abstract
Understanding the metabolism of pharmaceutical compounds is a fundamental prerequisite for ensuring their safety and efficacy in clinical use. However, conventional methods for monitoring drug metabolism often come with the drawbacks of being time-consuming and costly. In an ongoing quest for innovative approaches, the application of electrochemistry in metabolism studies has gained prominence as a promising approach for the synthesis and analysis of drug transformation products. In this study, we investigated the hepatic metabolism of voriconazole, an antifungal medication, by utilizing human liver microsomes (HLM) assay coupled with LC-MS. Based on the obtained results, the electrochemical parameters were optimized to simulate the biotransformation reactions. Among the various electrodes tested, the chemometric analysis revealed that the iron(II) phthalocyanine electrode was the most effective in catalyzing the formation of all hepatic voriconazole metabolites. These findings exemplify the potential of phthalocyanine electrodes as an efficient and cost-effective tool for simulating the intricate metabolic processes involved in drug biotransformation, offering new possibilities in the field of pharmaceutical research. Additionally, in silico analysis showed that two detected metabolites may exhibit significantly higher acute toxicity and mutagenic potential than the parent compound.
Collapse
Affiliation(s)
| | | | - Robert Skibiński
- Department of Medicinal Chemistry, Faculty of Pharmacy, Medical University of Lublin, Jaczewskiego 4, 20-090 Lublin, Poland; (M.W.); (J.T.)
| |
Collapse
|
8
|
McMahon CJ, Martinez B, Henry CS. Characterization of Factors Affecting Stripping Voltammetry on Thermoplastic Electrodes. JOURNAL OF THE ELECTROCHEMICAL SOCIETY 2023; 170:096507. [PMID: 37807977 PMCID: PMC10552556 DOI: 10.1149/1945-7111/acfa68] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/10/2023]
Abstract
Thermoplastic carbon electrodes (TPEs) are an alternative form of carbon composite electrodes that have shown excellent electrochemical performance with applications in biological sensing. However, little has been done to apply TPEs to environmental sensing, specifically heavy metal analysis. The work here focuses on lead analysis and based on their electrochemical properties, TPEs are expected to outperform other carbon composite materials; however, despite testing multiple formulations, TPEs showed inferior performance. Detailed electrode characterization was conducted to examine the cause for poor lead sensing behavior. X-Ray photoelectron spectroscopy (XPS) was used to analyze the surface functional groups, indicating that acidic and alkaline functional groups impact lead electrodeposition. Further, scanning electron microscopy (SEM) and electrochemical characterization demonstrated that both the binder and graphite can influence the surface morphology, electroactive area, and electron kinetics.
Collapse
Affiliation(s)
| | | | - Charles S Henry
- Colorado State University, Fort Collins, Colorado 80523, USA
| |
Collapse
|
9
|
Zhao Y, Wang X, Sun T, Shan P, Zhan Z, Zhao Z, Jiang Y, Qu M, Lv Q, Wang Y, Liu P, Chen S. Artificial intelligence-driven electrochemical immunosensing biochips in multi-component detection. BIOMICROFLUIDICS 2023; 17:041301. [PMID: 37614678 PMCID: PMC10444200 DOI: 10.1063/5.0160808] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Accepted: 08/01/2023] [Indexed: 08/25/2023]
Abstract
Electrochemical Immunosensing (EI) combines electrochemical analysis and immunology principles and is characterized by its simplicity, rapid detection, high sensitivity, and specificity. EI has become an important approach in various fields, such as clinical diagnosis, disease prevention and treatment, environmental monitoring, and food safety. However, EI multi-component detection still faces two major bottlenecks: first, the lack of cost-effective and portable detection platforms; second, the difficulty in eliminating batch differences and accurately decoupling signals from multiple analytes. With the gradual maturation of biochip technology, high-throughput analysis and portable detection utilizing the advantages of miniaturized chips, high sensitivity, and low cost have become possible. Meanwhile, Artificial Intelligence (AI) enables accurate decoupling of signals and enhances the sensitivity and specificity of multi-component detection. We believe that by evaluating and analyzing the characteristics, benefits, and linkages of EI, biochip, and AI technologies, we may considerably accelerate the development of EI multi-component detection. Therefore, we propose three specific prospects: first, AI can enhance and optimize the performance of the EI biochips, addressing the issue of multi-component detection for portable platforms. Second, the AI-enhanced EI biochips can be widely applied in home care, medical healthcare, and other areas. Third, the cross-fusion and innovation of EI, biochip, and AI technologies will effectively solve key bottlenecks in biochip detection, promoting interdisciplinary development. However, challenges may arise from AI algorithms that are difficult to explain and limited data access. Nevertheless, we believe that with technological advances and further research, there will be more methods and technologies to overcome these challenges.
Collapse
Affiliation(s)
- Yuliang Zhao
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066000, Hebei, China
| | - Xiaoai Wang
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066000, Hebei, China
| | - Tingting Sun
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066000, Hebei, China
| | - Peng Shan
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066000, Hebei, China
| | - Zhikun Zhan
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066000, Hebei, China
| | - Zhongpeng Zhao
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences (AMMS), Beijing 100071, China
| | - Yongqiang Jiang
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences (AMMS), Beijing 100071, China
| | - Mingyue Qu
- The PLA Rocket Force Characteristic Medical Center, Beijing 100088, China
| | - Qingyu Lv
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences (AMMS), Beijing 100071, China
| | - Ying Wang
- School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China
| | - Peng Liu
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences (AMMS), Beijing 100071, China
| | - Shaolong Chen
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences (AMMS), Beijing 100071, China
| |
Collapse
|
10
|
Wu Y, Zhang T, Su L, Wu X. Electrodeposited rGO/AuNP/MnO 2 Nanocomposite-Modified Screen-Printed Carbon Electrode for Sensitive Electrochemical Sensing of Arsenic(III) in Water. BIOSENSORS 2023; 13:bios13050563. [PMID: 37232924 DOI: 10.3390/bios13050563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 05/15/2023] [Accepted: 05/18/2023] [Indexed: 05/27/2023]
Abstract
Herein, a simple and portable electrochemical sensor based on a reduced graphene oxide/gold nanoparticle/manganese dioxide (rGO/AuNP/MnO2) nanocomposite-modified screen-printed carbon electrode (SPCE) was constructed by the facile stepwise electrodeposition method and used for electrochemical detection of As(III). The resultant electrode was characterized for its morphological, structural, and electrochemical properties using scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), energy dispersive X-ray spectroscopy (EDX), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). From the morphologic structure, it can be clearly observed that the AuNPs and MnO2 alone or their hybrid were densely deposited or entrapped in thin rGO sheets on the porous carbon surface, which may favor the electro-adsorption of As(III) on the modified SPCE. It is interesting that the nanohybrid modification endows the electrode with a significant decrease in charge transfer resistance and an increase in electroactive specific surface area, which dramatically increases the electro-oxidation current of As(III). This improved sensing ability was ascribed to the synergistic effect of gold nanoparticles with excellent electrocatalytic property and reduced graphene oxide with good electrical conductivity, as well as the involvement of manganese dioxide with a strong adsorption property in the electrochemical reduction of As(III). Under optimized conditions, the sensor can detect As(III) via square wave anodic stripping voltammetry (SWASV) with a low limit of detection of 2.4 μg L-1 and a linear range of 25-200 μg L-1. The proposed portable sensor shows the advantages of a simple preparation procedure, low cost, good repeatability, and long-term stability. The feasibility of rGO/AuNPs/MnO2/SPCE for detecting As(III) in real water was further verified.
Collapse
Affiliation(s)
- Yanqing Wu
- Key Laboratory for Analytical Science of Food Safety and Biology (Ministry of Education & Fujian Province), College of Chemistry, Fuzhou University, Fuzhou 350116, China
| | - Tao Zhang
- Key Laboratory for Analytical Science of Food Safety and Biology (Ministry of Education & Fujian Province), College of Chemistry, Fuzhou University, Fuzhou 350116, China
| | - Lishen Su
- Key Laboratory for Analytical Science of Food Safety and Biology (Ministry of Education & Fujian Province), College of Chemistry, Fuzhou University, Fuzhou 350116, China
| | - Xiaoping Wu
- Key Laboratory for Analytical Science of Food Safety and Biology (Ministry of Education & Fujian Province), College of Chemistry, Fuzhou University, Fuzhou 350116, China
| |
Collapse
|
11
|
Chen Y, Zhao P, Liang Y, Ma Y, Liu Y, Zhao J, Hou J, Hou C, Huo D. A sensitive electrochemical sensor based on 3D porous melamine-doped rGO/MXene composite aerogel for the detection of heavy metal ions in the environment. Talanta 2023; 256:124294. [PMID: 36696736 DOI: 10.1016/j.talanta.2023.124294] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2022] [Revised: 01/13/2023] [Accepted: 01/19/2023] [Indexed: 01/22/2023]
Abstract
Herein, we developed a unique screen-printed carbon electrode (SPCE) with three-dimensional melamine-doped graphene oxide/MXene composite aerogel (3D MGMA) modification, which is used for the simultaneous and sensitive detection of three metal ions (Zn2+, Cd2+, and Pb2+) in the environment. A self-assembly method was used to fabricate 3D MXene aerogels based on MXene, graphene oxide (GO), and melamine. Notably, the network-like 3D structure combining 2D MXene and rGO sheets can provide a high ratio of surface area and enriched functional clusters, which are beneficial for improving the electrical conductivity and promoting the uptake of heavy metal ions. In the linear range of 3-900 μg L-1, the constructed innovative sensing platform can sensitively detect Zn2+, Cd2+, and Pb2+ simultaneously, with detection limits of 0.48 μg L-1,0.45 μg L-1 and 0.29 μg L-1 respectively. This work reflects precision and reliability in the detection of three water samples (tap water, Minzhu lake and Yangtze River) and four cereal samples (sorghum, rice, wheat and corn), proposing a novel strategy for monitoring heavy metal ions in the natural environment.
Collapse
Affiliation(s)
- Yuanyuan Chen
- Key Laboratory for Biorheological Science and Technology (Chongqing University), Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, PR China
| | - Peng Zhao
- Key Laboratory for Biorheological Science and Technology (Chongqing University), Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, PR China
| | - Yi Liang
- Key Laboratory for Biorheological Science and Technology (Chongqing University), Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, PR China
| | - Yi Ma
- Liquor Making Biology Technology and Application of Key Laboratory of Sichuan Province, College of Bioengineering, Sichuan University of Science and Engineering, 188 University Town, Yibin, 644000, PR China
| | - Yiyi Liu
- Key Laboratory for Biorheological Science and Technology (Chongqing University), Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, PR China
| | - Jinsong Zhao
- Liquor Making Biology Technology and Application of Key Laboratory of Sichuan Province, College of Bioengineering, Sichuan University of Science and Engineering, 188 University Town, Yibin, 644000, PR China; Sichuan Liqour Group Co., Ltd, Chengdu, 610000, PR China
| | - Jingzhou Hou
- Postdoctoral Research Station, Chongqing University, Bioengineering College of Chongqing University, Chongqing, 400044, PR China; Chongqing Engineering and Technology Research Center of Intelligent Rehabilitation and Eldercare, Chongqing City Management College, Chongqing, 401331, PR China.
| | - Changjun Hou
- Liquor Making Biology Technology and Application of Key Laboratory of Sichuan Province, College of Bioengineering, Sichuan University of Science and Engineering, 188 University Town, Yibin, 644000, PR China.
| | - Danqun Huo
- Key Laboratory for Biorheological Science and Technology (Chongqing University), Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, PR China; Liquor Making Biology Technology and Application of Key Laboratory of Sichuan Province, College of Bioengineering, Sichuan University of Science and Engineering, 188 University Town, Yibin, 644000, PR China.
| |
Collapse
|
12
|
Musa AM, Kiely J, Luxton R, Honeychurch KC. An Electrochemical Screen-Printed Sensor Based on Gold-Nanoparticle-Decorated Reduced Graphene Oxide-Carbon Nanotubes Composites for the Determination of 17-β Estradiol. BIOSENSORS 2023; 13:bios13040491. [PMID: 37185565 PMCID: PMC10136424 DOI: 10.3390/bios13040491] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 04/07/2023] [Accepted: 04/10/2023] [Indexed: 05/17/2023]
Abstract
In this study, a screen-printed electrode (SPE) modified with gold-nanoparticle-decorated reduced graphene oxide-carbon nanotubes (rGO-AuNPs/CNT/SPE) was used for the determination of estradiol (E2). The AuNPs were produced through an eco-friendly method utilising plant extract, eliminating the need for severe chemicals, and remove the requirements of sophisticated fabrication methods and tedious procedures. In addition, rGO-AuNP serves as a dispersant for the CNT to improve the dispersion stability of CNTs. The composite material, rGO-AuNPs/CNT, underwent characterisation through scanning electron microscopy (SEM), ultraviolet-visible absorption spectroscopy (UV-vis), Fourier-transform infrared (FTIR) spectroscopy, and atomic force microscopy (AFM). The electrochemical performance of the modified SPE for estradiol oxidation was characterised using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The rGO-AuNPs/CNT/SPE exhibited a notable improvement compared to bare/SPE and GO-CNT/SPE, as evidenced by the relative peak currents. Additionally, we employed a baseline correction algorithm to accurately adjust the sensor response while eliminating extraneous background components that are typically present in voltammetric experiments. The optimised estradiol sensor offers linear sensitivity from 0.05-1.00 µM, with a detection limit of 3 nM based on three times the standard deviation (3δ). Notably, this sensing approach yields stable, repeatable, and reproducible outcomes. Assessment of drinking water samples indicated an average recovery rate of 97.5% for samples enriched with E2 at concentrations as low as 0.5 µM%, accompanied by only a modest coefficient of variation (%CV) value of 2.7%.
Collapse
Affiliation(s)
- Auwal M Musa
- Institute of Bio-Sensing Technology (IBST), University of the West of England, Bristol BS16 1QY, UK
| | - Janice Kiely
- Centre for Research in Biosciences (CRIB), School of Applied Sciences, University of the West of England, Bristol BS16 1QY, UK
| | - Richard Luxton
- Centre for Research in Biosciences (CRIB), School of Applied Sciences, University of the West of England, Bristol BS16 1QY, UK
| | - Kevin C Honeychurch
- Institute of Bio-Sensing Technology (IBST), University of the West of England, Bristol BS16 1QY, UK
- Centre for Research in Biosciences (CRIB), School of Applied Sciences, University of the West of England, Bristol BS16 1QY, UK
| |
Collapse
|
13
|
Bressi V, Chiarotto I, Ferlazzo A, Celesti C, Michenzi C, Len T, Iannazzo D, Neri G, Espro C. Voltammetric Sensor Based on Waste‐Derived Carbon Nanodots for Enhanced Detection of Nitrobenzene. ChemElectroChem 2023. [DOI: 10.1002/celc.202300004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/12/2023]
Affiliation(s)
- Viviana Bressi
- Department of Engineering University of Messina Contrada di Dio–Vill. S. Agata I-98166 Messina Italy
- Department of Organic Chemistry University of Córdoba Campus de Rabanales, Marie Curie (C-3), Ctra Nnal IV−A Km 396 Cordoba Spain
| | - Isabella Chiarotto
- Department of Basic and Applied Sciences for Engineering (SBAI) Sapienza University of Rome Via Castro Laurenziano, 7 00161 Rome Italy
| | - Angelo Ferlazzo
- Department of Engineering University of Messina Contrada di Dio–Vill. S. Agata I-98166 Messina Italy
| | - Consuelo Celesti
- Department of Engineering University of Messina Contrada di Dio–Vill. S. Agata I-98166 Messina Italy
- Department of Clinical and Experimental Medicine University of Messina Via Consolare Valeria 98125 Messina Italy
| | - Cinzia Michenzi
- Department of Basic and Applied Sciences for Engineering (SBAI) Sapienza University of Rome Via Castro Laurenziano, 7 00161 Rome Italy
| | - Thomas Len
- Department of Organic Chemistry University of Córdoba Campus de Rabanales, Marie Curie (C-3), Ctra Nnal IV−A Km 396 Cordoba Spain
| | - Daniela Iannazzo
- Department of Engineering University of Messina Contrada di Dio–Vill. S. Agata I-98166 Messina Italy
| | - Giovanni Neri
- Department of Engineering University of Messina Contrada di Dio–Vill. S. Agata I-98166 Messina Italy
| | - Claudia Espro
- Department of Engineering University of Messina Contrada di Dio–Vill. S. Agata I-98166 Messina Italy
| |
Collapse
|
14
|
Shalaby EA, Beltagi AM, Hathoot AA, Azzem MA. Simultaneous voltammetric sensing of Zn 2+, Cd 2+, and Pb 2+ using an electrodeposited Bi-Sb nanocomposite modified carbon paste electrode. RSC Adv 2023; 13:7118-7128. [PMID: 36875874 PMCID: PMC9978880 DOI: 10.1039/d3ra00168g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Accepted: 02/22/2023] [Indexed: 03/06/2023] Open
Abstract
A sensor for detecting Zn2+, Cd2+, and Pb2+ ions simultaneously based on the square wave anodic stripping response at a bismuth antimony (Bi-Sb) nanocomposite electrode was developed. The electrode was prepared in situ by electrodepositing bismuth and antimony on the surface of a carbon-paste electrode (CPE) while also reducing the analyte metal ions. The structure and performance of the Bi-Sb/CPE electrode were studied using scanning electron microscopy, X-ray diffraction, electrochemical impedance spectroscopy, and cyclic voltammetry. Operational conditions including the concentration of Sb and Bi, the type of electrolyte, pH, and preconcentration conditions were optimized. The linear ranges were determined to be 5-200 μg L-1 for Zn2+, 1-200 μg L-1 for Cd2+, and 1-150 μg L-1 for Pb2+ with the optimized parameters. The limits of detection were 1.46 μg L-1, 0.27 μg L-1, and 0.29 μg L-1 for Zn2+, Cd2+, and Pb2+, respectively. Furthermore, the Bi-Sb/CPE sensor is capable of selective determination of the target metals in the presence of the common cationic and anionic interfering species (Na+, K+, Ca2+, Mg2+, Fe3+, Mn2+, Co2+, Cl-, SO4 2- and HCO3 -). Finally, the sensor was successfully applied to the simultaneous determination of Zn2+, Cd2+, and Pb2+ in a variety of real-world water samples.
Collapse
Affiliation(s)
- E A Shalaby
- Electrochemistry Laboratory, Chemistry Department, Faculty of Science, Menoufia University Shebin El-Kom 32511 Egypt
| | - A M Beltagi
- Department of Chemistry, Faculty of Science, Kafrelsheikh University Kafrelsheikh 33516 Egypt
| | - A A Hathoot
- Electrochemistry Laboratory, Chemistry Department, Faculty of Science, Menoufia University Shebin El-Kom 32511 Egypt
| | - M Abdel Azzem
- Electrochemistry Laboratory, Chemistry Department, Faculty of Science, Menoufia University Shebin El-Kom 32511 Egypt
| |
Collapse
|
15
|
Barzkar M, Ghiasvand A, Safdarian M. A simple and cost-effective synthesis route using itaconic acid to prepare a magnetic ion-imprinted polymer for preconcentration of Pb (II) from aqueous media. Talanta 2023; 259:124501. [PMID: 37031540 DOI: 10.1016/j.talanta.2023.124501] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 03/02/2023] [Accepted: 03/29/2023] [Indexed: 04/03/2023]
Abstract
A new Pb (II) magnetic ion-imprinted polymer (Pb-MIIP) was successfully investigated for the selective extraction of Pb (II) from an aqueous solution. MIIP nanostructures were developed using itaconic acid-coated iron oxide nanoparticles (Fe3O4@ITA) as a novel magnetic core, ITA as a functional monomer and chelating agent, ethylene glycol dimethacrylate (EGDMA) as a cross-linker, and 2,2-azobisisobutyronitrile (AIBN) as an initiator. The triple application of ITA in the synthesis and reduction of the number of compounds in the preparation of the MIIP, in addition to being economical, reduces the possibility of side reactions. The synthesized products were followed and confirmed in each step by instrumental and microscopic methods. The limit of detection of the Pb (II)-MIIP method was 0.21 μg L-1. Under the optimal conditions, the recovery (R%) was >90% with a relative standard deviation (RSD%) of <4.9%. The synthesized MIIP was reusable and successfully used to extract Pb (II) from tap water samples.
Collapse
Affiliation(s)
- Minoo Barzkar
- Nanotechnology Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Alireza Ghiasvand
- Department of Chemistry, Faculty of Science, Lorestan University, Khoramabad, Iran; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, Tasmania, 7001, Australia
| | - Mehdi Safdarian
- Nanotechnology Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
| |
Collapse
|
16
|
Selvolini G, Marrazza G. On spot detection of nickel and cobalt from exhausted batteries by a smart electrochemical sensor. Talanta 2023; 253:123918. [PMID: 36088847 DOI: 10.1016/j.talanta.2022.123918] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 08/29/2022] [Accepted: 09/04/2022] [Indexed: 12/13/2022]
Abstract
This work presents the realization and the application of an user-friendly electrochemical platform based on screen-printed electrodes for the simultaneous determination of nickel and cobalt ions in real samples by means of square wave adsorptive stripping voltammetry (SWAdSV). The sensor was realized by electrodepositing in situ a bismuth film onto graphite screen-printed electrodes (GSPEs). The sensor surface was fully characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The experimental conditions for the determination of nickel and cobalt in the form of dimethylglyoximate complexes were studied and optimized. Linear calibration curves for Ni(II) and Co(II), determined individually and together, in the range 10-40 μg/L for nickel and 10-60 μg/L for cobalt, respectively, were obtained. The limits of detection for nickel and cobalt determination were 2.5 μg/L and 2.4 μg/L, respectively. The performance of the sensor in terms of reproducibility and selectivity was also studied. The applicability of the developed platform was assessed by determining nickel and cobalt in samples deriving from an industrial process of recycling exhausted batteries and in soil samples.
Collapse
Affiliation(s)
- Giulia Selvolini
- "Ugo Schiff" Chemistry Department, University of Florence, Via Della Lastruccia 3, 50019 Sesto Fiorentino (FI), Italy
| | - Giovanna Marrazza
- "Ugo Schiff" Chemistry Department, University of Florence, Via Della Lastruccia 3, 50019 Sesto Fiorentino (FI), Italy.
| |
Collapse
|
17
|
Thuy NTD, Wang X, Zhao G, Liang T, Zou Z. A Co 3O 4 Nanoparticle-Modified Screen-Printed Electrode Sensor for the Detection of Nitrate Ions in Aquaponic Systems. SENSORS (BASEL, SWITZERLAND) 2022; 22:9730. [PMID: 36560098 PMCID: PMC9787752 DOI: 10.3390/s22249730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 12/05/2022] [Accepted: 12/09/2022] [Indexed: 06/17/2023]
Abstract
In this study, a screen-printed electrode (SPE) modified with cobalt oxide nanoparticles (Co3O4 NPs) was used to create an all-solid-state ion-selective electrode used as a potentiometric ion sensor for determining nitrate ion (NO3-) concentrations in aquaculture water. The effects of the Co3O4 NPs on the characterization parameters of the solid-contact nitrate ion-selective electrodes (SC-NO3--ISEs) were investigated. The morphology, physical properties and analytical performance of the proposed NO3--ion selective membrane (ISM)/Co3O4 NPs/SPEs were studied by X-ray diffraction (XRD), energy-dispersive spectroscopy (EDS), transmission electron microscopy (TEM), scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), potentiometric measurements, and potentiometric water layer tests. Once all conditions were optimized, it was confirmed that the screen-printed electrochemical sensor had high potential stability, anti-interference performance, good reproducibility, and no water layer formation between the selective membrane and the working electrode. The developed NO3--ISM/Co3O4 NPs/SPE showed a Nernstian slope of -56.78 mV/decade for NO3- detection with a wide range of 10-7-10-2 M and a quick response time of 5.7 s. The sensors were successfully used to measure NO3- concentrations in aquaculture water. Therefore, the electrodes have potential for use in aquaponic nutrient solution applications with precise detection of NO3- in a complicated matrix and can easily be used to monitor other ions in aquaculture water.
Collapse
Affiliation(s)
| | - Xiaochan Wang
- College of Engineering, Nanjing Agricultural University, Nanjing 210031, China
| | - Guo Zhao
- College of Artificial Intelligence, Nanjing Agricultural University, Nanjing 210031, China
| | - Tingyu Liang
- College of Artificial Intelligence, Nanjing Agricultural University, Nanjing 210031, China
| | - Zaihan Zou
- College of Artificial Intelligence, Nanjing Agricultural University, Nanjing 210031, China
| |
Collapse
|
18
|
Prospective analytical role of sensors for environmental screening and monitoring. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
19
|
An optical and electrochemical sensor based on L-arginine functionalized reduced graphene oxide. Sci Rep 2022; 12:19398. [PMID: 36371538 PMCID: PMC9653396 DOI: 10.1038/s41598-022-23949-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 11/08/2022] [Indexed: 11/15/2022] Open
Abstract
The electrochemical and photochemical properties of graphene derivatives could be significantly improved by modifications in the chemical structure. Herein, reduced graphene oxide (RGO) was functionalized with L-arginine (L-Arg) by an amidation reaction between the support and amino acid. Deposition of a powerful ligand, L-Arg, on the optically active support generated an effective optical chemosensor for the determination of Cd(II), Co(II), Pb(II), and Cu(II). In addition, L-Arg-RGO was used as an electrode modifier to fabricate L-Arg-RGO modified glassy-carbon electrode (L-Arg-RGO/GCE) to be employed in the selective detection of Pb(II) ions by differential pulse anodic stripping voltammetry (DP-ASV). L-Arg-RGO/GCE afforded better results than the bare GCE, RGO/GCE, and L-Arg functionalized graphene quantum dot modified GCE. The nanostructure of RGO, modification by L-Arg, and homogeneous immobilization of resultant nanoparticles at the electrode surface are the reasons for outstanding results. The proposed electrochemical sensor has a wide linear range with a limit of detection equal to 0.06 nM, leading to the easy detection of Pb(II) in the presence of other cations. This research highlighted that RGO as a promising support of optical, and electrochemical sensors could be used in the selective, and sensitive determination of transition metals depends on the nature of the modifier. Moreover, L-Arg as an abundant amino acid deserves to perch on the support for optical, and electrochemical determination of transition metals.
Collapse
|
20
|
Liaquat H, Imran M, Latif S, Hussain N, Bilal M. Multifunctional nanomaterials and nanocomposites for sensing and monitoring of environmentally hazardous heavy metal contaminants. ENVIRONMENTAL RESEARCH 2022; 214:113795. [PMID: 35803339 DOI: 10.1016/j.envres.2022.113795] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 05/25/2022] [Accepted: 06/27/2022] [Indexed: 06/15/2023]
Abstract
The applications of conventional sensors are limited by the long response time, high cost, large detection limit, low sensitivity, complicated usage and low selectivity. These sensors are nowadays replaced by Nanocomposite-based modalities and nanomaterials which are known for their high selectivity and physical and chemical properties. These nanosensors effectively detect heavy metal contaminants in the environment as the discharge of heavy metals into natural water as a result of human activity has become a global epidemic. Exposure to these toxic metals might induce many health-related complications, including kidney failure, brain injury, immune disorders, muscle paleness, cardiac damage, nervous system impairment and limb paralysis. Therefore, designing and developing novel sensing systems for the detection and recognition of these harmful metals in various environmental matrices, particularly water, is of extremely important. Emerging nanotechnological approaches in the past two decades have played a key role in overcoming environmentally-related problems. Nanomaterial-based fabrication of chemical nanosensors has widely been applied as a powerful analytical tool for sensing heavy metals. Portability, high sensitivity, on-site detection capability, better device performance and selectivity are all advantages of these nanosensors. The detection and selectivity have been improved using molecular recognition probes for selective binding on different nanostructures. This study aims to evaluate the sensing properties of various nanomaterials such as metal-organic frameworks, fluorescent materials, metal-based nanoparticles, carbon-based nanomaterials and quantum dots and graphene-based nanomaterials and quantum dots for heavy metal ions recognition. All these nano-architectures are frequently served as effective fluorescence probes to directly (or by modification with some large or small biomolecules) sense heavy metal ions for improved selectivity. However, efforts are still needed for the simultaneous designing of multiple metal ion-based detection systems, exclusively in colorimetric or optical fluorescence nanosensors for heavy metal cations.
Collapse
Affiliation(s)
- Hina Liaquat
- Centre for Inorganic Chemistry, School of Chemistry, University of the Punjab, Lahore, 54000, Pakistan
| | - Muhammad Imran
- Centre for Inorganic Chemistry, School of Chemistry, University of the Punjab, Lahore, 54000, Pakistan
| | - Shoomaila Latif
- School of Physical Sciences, University of the Punjab, Lahore, 54000, Pakistan
| | - Nazim Hussain
- Center for Applied Molecular Biology (CAMB), University of the Punjab, Lahore, 54000, Pakistan
| | - Muhammad Bilal
- School of Life Science and Food Engineering, Huaiyin Institute of Technology, Huaian, 223003, China.
| |
Collapse
|
21
|
|
22
|
Molinara M, Cancelliere R, Di Tinno A, Ferrigno L, Shuba M, Kuzhir P, Maffucci A, Micheli L. A Deep Learning Approach to Organic Pollutants Classification Using Voltammetry. SENSORS (BASEL, SWITZERLAND) 2022; 22:8032. [PMID: 36298383 PMCID: PMC9608622 DOI: 10.3390/s22208032] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Revised: 10/18/2022] [Accepted: 10/18/2022] [Indexed: 05/27/2023]
Abstract
This paper proposes a deep leaning technique for accurate detection and reliable classification of organic pollutants in water. The pollutants are detected by means of cyclic voltammetry characterizations made by using low-cost disposable screen-printed electrodes. The paper demonstrates the possibility of strongly improving the detection of such platforms by modifying them with nanomaterials. The classification is addressed by using a deep learning approach with convolutional neural networks. To this end, the results of the voltammetry analysis are transformed into equivalent RGB images by means of Gramian angular field transformations. The proposed technique is applied to the detection and classification of hydroquinone and benzoquinone, which are particularly challenging since these two pollutants have a similar electroactivity and thus the voltammetry curves exhibit overlapping peaks. The modification of electrodes by carbon nanotubes improves the sensitivity of a factor of about ×25, whereas the convolution neural network after Gramian transformation correctly classifies 100% of the experiments.
Collapse
Affiliation(s)
- Mario Molinara
- Department of Electrical and Information Engineering, University of Cassino and Southern Lazio, 03043 Cassino, Italy
| | - Rocco Cancelliere
- Department of Chemical Science and Technologies, University of Rome “Tor Vergata”, 00133 Rome, Italy
| | - Alessio Di Tinno
- Department of Chemical Science and Technologies, University of Rome “Tor Vergata”, 00133 Rome, Italy
| | - Luigi Ferrigno
- Department of Electrical and Information Engineering, University of Cassino and Southern Lazio, 03043 Cassino, Italy
| | - Mikhail Shuba
- Center of Physical Science and Technologies, 10257 Vilnius, Lithuania
| | - Polina Kuzhir
- Institute of Photonics, Department of Physics and Mathematics, University of Eastern Finland, 80101 Joensuu, Finland
| | - Antonio Maffucci
- Department of Electrical and Information Engineering, University of Cassino and Southern Lazio, 03043 Cassino, Italy
- INFN, Italian National Institute for Nuclear Physics, 00044 Frascati, Italy
| | - Laura Micheli
- Department of Chemical Science and Technologies, University of Rome “Tor Vergata”, 00133 Rome, Italy
| |
Collapse
|
23
|
Beitollahi H, Dourandish Z, Tajik S, Sharifi F, Jahani PM. Electrochemical Sensor Based on Ni-Co Layered Double Hydroxide Hollow Nanostructures for Ultrasensitive Detection of Sumatriptan and Naproxen. BIOSENSORS 2022; 12:bios12100872. [PMID: 36291009 PMCID: PMC9599541 DOI: 10.3390/bios12100872] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 10/02/2022] [Accepted: 10/06/2022] [Indexed: 06/12/2023]
Abstract
In this work, Ni-Co layered double hydroxide (Ni-Co LDH) hollow nanostructures were synthesized and characterized by X-ray diffraction (XRD), field emission-scanning electron microscopy (FE-SEM), and Fourier-transform infrared spectroscopy (FT-IR) techniques. A screen-printed electrode (SPE) surface was modified with as-fabricated Ni-Co LDHs to achieve a new sensing platform for determination of sumatriptan. The electrochemical behavior of the Ni-Co LDH-modified SPE (Ni-CO LDH/SPE) for sumatriptan determination was investigated using voltammetric methods. Compared with bare SPE, the presence of Ni-Co LDH was effective in the enhancement of electron transport rate between the electrode and analyte, as well as in the significant reduction of the overpotential of sumatriptan oxidation. Differential pulse voltammetry (DPV) was applied to perform a quantitative analysis of sumatriptan. The linearity range was found to be between 0.01 and 435.0 μM. The limits of detection (LOD) and sensitivity were 0.002 ± 0.0001 μM and 0.1017 ± 0.0001 μA/μM, respectively. In addition, the performance of the Ni-CO LDH/SPE for the determination of sumatriptan in the presence of naproxen was studied. Simultaneous analysis of sumatriptan with naproxen showed well-separated peaks leading to a quick and selective analysis of sumatriptan. Furthermore, the practical applicability of the prepared Ni-CO LDH/SPE sensor was examined in pharmaceutical and biological samples with satisfactory recovery results.
Collapse
Affiliation(s)
- Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman 7631885356, Iran
| | - Zahra Dourandish
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman, Kerman 76175-133, Iran
| | - Somayeh Tajik
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman 7616913555, Iran
| | - Fatemeh Sharifi
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman 7616913555, Iran
| | | |
Collapse
|
24
|
Sirin Ustabasi G, Bastos-Arrieta J, Pérez-Ràfols C, Serrano N, Díaz-Cruz JM. Considerations on the use of spectroelectrochemistry in reflection mode for quantitative analysis: Study of the Fe(III)/Fe(II) – orthophenanthroline system. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
25
|
Antimony nanomaterials modified screen-printed electrodes for the voltammetric determination of metal ions. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.140690] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
26
|
Simultaneous determination of iron and copper using screen-printed carbon electrodes by adsorptive stripping voltammetry with o-phenanthroline. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107597] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
27
|
A Critical Review on the Use of Molecular Imprinting for Trace Heavy Metal and Micropollutant Detection. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10080296] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Molecular recognition has been described as the “ultimate” form of sensing and plays a fundamental role in biological processes. There is a move towards biomimetic recognition elements to overcome inherent problems of natural receptors such as limited stability, high-cost, and variation in response. In recent years, several alternatives have emerged which have found their first commercial applications. In this review, we focus on molecularly imprinted polymers (MIPs) since they present an attractive alternative due to recent breakthroughs in polymer science and nanotechnology. For example, innovative solid-phase synthesis methods can produce MIPs with sometimes greater affinities than natural receptors. Although industry and environmental agencies require sensors for continuous monitoring, the regulatory barrier for employing MIP-based sensors is still low for environmental applications. Despite this, there are currently no sensors in this area, which is likely due to low profitability and the need for new legislation to promote the development of MIP-based sensors for pollutant and heavy metal monitoring. The increased demand for point-of-use devices and home testing kits is driving an exponential growth in biosensor production, leading to an expected market value of over GPB 25 billion by 2023. A key requirement of point-of-use devices is portability, since the test must be conducted at “the time and place” to pinpoint sources of contamination in food and/or water samples. Therefore, this review will focus on MIP-based sensors for monitoring pollutants and heavy metals by critically evaluating relevant literature sources from 1993 to 2022.
Collapse
|
28
|
Keyvan Rad J, Balzade Z, Mahdavian AR. Spiropyran-based advanced photoswitchable materials: A fascinating pathway to the future stimuli-responsive devices. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY C: PHOTOCHEMISTRY REVIEWS 2022. [DOI: 10.1016/j.jphotochemrev.2022.100487] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
29
|
A Review on Flexible Electrochemical Biosensors to Monitor Alcohol in Sweat. BIOSENSORS 2022; 12:bios12040252. [PMID: 35448313 PMCID: PMC9026542 DOI: 10.3390/bios12040252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 04/05/2022] [Accepted: 04/06/2022] [Indexed: 11/17/2022]
Abstract
The continued focus on improving the quality of human life has encouraged the development of increasingly efficient, durable, and cost-effective products in healthcare. Over the last decade, there has been substantial development in the field of technical and interactive textiles that combine expertise in electronics, biology, chemistry, and physics. Most recently, the creation of textile biosensors capable of quantifying biometric data in biological fluids is being studied, to detect a specific disease or the physical condition of an individual. The ultimate goal is to provide access to medical diagnosis anytime and anywhere. Presently, alcohol is considered the most commonly used addictive substance worldwide, being one of the main causes of death in road accidents. Thus, it is important to think of solutions capable of minimizing this public health problem. Alcohol biosensors constitute an excellent tool to aid at improving road safety. Hence, this review explores concepts about alcohol biomarkers, the composition of human sweat and the correlation between alcohol and blood. Different components and requirements of a biosensor are reviewed, along with the electrochemical techniques to evaluate its performance, in addition to construction techniques of textile-based biosensors. Special attention is given to the determination of biomarkers that must be low cost and fast, so the use of biomimetic materials to recognize and detect the target analyte is turning into an attractive option to improve electrochemical behavior.
Collapse
|
30
|
Matvieiev O, Šelešovská R, Vojs M, Marton M, Michniak P, Hrdlička V, Hatala M, Janíková L, Chýlková J, Skopalová J, Cankař P, Navrátil T. Novel Screen-Printed Sensor with Chemically Deposited Boron-Doped Diamond Electrode: Preparation, Characterization, and Application. BIOSENSORS 2022; 12:bios12040241. [PMID: 35448301 PMCID: PMC9027657 DOI: 10.3390/bios12040241] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 04/08/2022] [Accepted: 04/11/2022] [Indexed: 05/27/2023]
Abstract
New screen-printed sensor with a boron-doped diamond working electrode (SP/BDDE) was fabricated using a large-area linear antenna microwave chemical deposition vapor system (LA-MWCVD) with a novel precursor composition. It combines the advantages of disposable printed sensors, such as tailored design, low cost, and easy mass production, with excellent electrochemical properties of BDDE, including a wide available potential window, low background currents, chemical resistance, and resistance to passivation. The newly prepared SP/BDDEs were characterized by scanning electron microscopy (SEM) and Raman spectroscopy. Their electrochemical properties were investigated by cyclic voltammetry and electrochemical impedance spectroscopy using inner sphere ([Fe(CN)6]4-/3-) and outer sphere ([Ru(NH3)6]2+/3+) redox probes. Moreover, the applicability of these new sensors was verified by analysis of the anti-inflammatory drug lornoxicam in model and pharmaceutical samples. Using optimized differential pulse voltammetry in Britton-Robinson buffer of pH 3, detection limits for lornoxicam were 9 × 10-8 mol L-1. The oxidation mechanism of lornoxicam was investigated using bulk electrolysis and online electrochemical cell with mass spectrometry; nine distinct reaction steps and corresponding products and intermediates were identified.
Collapse
Affiliation(s)
- Oleksandr Matvieiev
- Institute of Environmental and Chemical Engineering, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10 Pardubice, Czech Republic; (O.M.); (L.J.); (J.C.)
| | - Renáta Šelešovská
- Institute of Environmental and Chemical Engineering, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10 Pardubice, Czech Republic; (O.M.); (L.J.); (J.C.)
| | - Marian Vojs
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava, Ilkovičova 3, 812 19 Bratislava, Slovakia; (M.V.); (M.M.); (P.M.)
| | - Marián Marton
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava, Ilkovičova 3, 812 19 Bratislava, Slovakia; (M.V.); (M.M.); (P.M.)
| | - Pavol Michniak
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava, Ilkovičova 3, 812 19 Bratislava, Slovakia; (M.V.); (M.M.); (P.M.)
| | - Vojtěch Hrdlička
- J. Heyrovsky Institute of Physical Chemistry of the Academy of Sciences of the Czech Republic, Dolejškova 3, 182 23 Prague, Czech Republic;
| | - Michal Hatala
- Department of Graphic Arts Technology and Applied Photochemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinského 9, 812 37 Bratislava, Slovakia;
| | - Lenka Janíková
- Institute of Environmental and Chemical Engineering, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10 Pardubice, Czech Republic; (O.M.); (L.J.); (J.C.)
| | - Jaromíra Chýlková
- Institute of Environmental and Chemical Engineering, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10 Pardubice, Czech Republic; (O.M.); (L.J.); (J.C.)
| | - Jana Skopalová
- Department of Analytical Chemistry, Faculty of Science, Palacký University in Olomouc, 17. listopadu 1192/12, 779 00 Olomouc, Czech Republic;
| | - Petr Cankař
- Department of Organic Chemistry, Faculty of Science, Palacký University in Olomouc, 17. listopadu 1192/12, 779 00 Olomouc, Czech Republic;
| | - Tomáš Navrátil
- J. Heyrovsky Institute of Physical Chemistry of the Academy of Sciences of the Czech Republic, Dolejškova 3, 182 23 Prague, Czech Republic;
| |
Collapse
|
31
|
Design, Elaboration, and Characterization of an Immunosensor for the Detection of a Fungal Toxin in Foodstuff Analyses. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10040137] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
This work describes the complete elaboration of an immunosensor for the detection of the fungal B1 aflatoxin (AFB1). In a first step, a system made of three screen-printed electrodes (SPEs) was manufactured using gold, silver/silver chloride, and carbon pastes. Raman spectroscopy showed that the thermal treatment applied to the electrodes enabled a strong decrease in the amount of undesirable organic molecules for each paste. Atomic Force Microscopy was also used to reveal the morphology of the electrode surfaces. In a second step, an autonomous and cheap electronic system was designed for the control of the sensor and electrochemical measurements, showing current variations significantly higher than those observed with a commercial system. In a last step, the gold working electrode of this system was functionalized by a simple self-assembly method, optimized in a previous work, with a molecular architecture including an antibody recognizing specifically AFB1. The complete device was finally realized by combining the SPEs and the electronic platform. The resulting setup was able to detect AFB1 toxin in a buffer with an LOD of about 50 fg/mL. It was then applied to the detection of AFB1 in rice milk, a more realistic medium comparable with those met in an agrifood context. The electrochemical detection of AFB1 was possible in a range of concentration between 0.5 pg/mL and 2.5 pg/mL, with the sensor behaving linearly in this range.
Collapse
|
32
|
Tyszczuk-Rotko K, Kozak J, Czech B. Screen-Printed Voltammetric Sensors-Tools for Environmental Water Monitoring of Painkillers. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22072437. [PMID: 35408052 PMCID: PMC9003516 DOI: 10.3390/s22072437] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Revised: 03/18/2022] [Accepted: 03/20/2022] [Indexed: 05/03/2023]
Abstract
The dynamic production and usage of pharmaceuticals, mainly painkillers, indicates the growing problem of environmental contamination. Therefore, the monitoring of pharmaceutical concentrations in environmental samples, mostly aquatic, is necessary. This article focuses on applying screen-printed voltammetric sensors for the voltammetric determination of painkillers residues, including non-steroidal anti-inflammatory drugs, paracetamol, and tramadol in environmental water samples. The main advantages of these electrodes are simplicity, reliability, portability, small instrumental setups comprising the three electrodes, and modest cost. Moreover, the electroconductivity, catalytic activity, and surface area can be easily improved by modifying the electrode surface with carbon nanomaterials, polymer films, or electrochemical activation.
Collapse
|
33
|
Voltammetric Determination of Active Pharmaceutical Ingredients Using Screen-Printed Electrodes. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10030095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
A simple, fast, sensitive and low-cost voltammetric method using a screen-printed carbon electrode (SPCE) is presented in this work for the simultaneous determination of ascorbic acid (AA), paracetamol (PA), dextromethorphan (DX) and caffeine (CF) in both pharmaceutical formulations and samples of environmental interest. The oxidative peak current displayed linear dependence on concentration within the range 1.7–60.5, 0.6–40.0, 0.9–8.4 (1st linear part) and 1.8–22.0 mg L−1 for AA, PA, DX and CF, respectively; and detection limits of 0.5, 0.2, 0.3 and 0.5 mg L−1, respectively. The developed differential pulse voltammetric (DPV) method was validated using both a pharmaceutical product and a spiked well water sample. A very good agreement between the determined and the theoretical label drug content and recoveries in the range of 99.5–100.8% were obtained for pharmaceutical product and well water samples, respectively.
Collapse
|
34
|
Electrochemical evaluation of Cd2+ and Hg2+ ions in water using ZnO/Cu2ONPs/PANI modified SPCE electrode. SENSING AND BIO-SENSING RESEARCH 2022. [DOI: 10.1016/j.sbsr.2022.100476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
35
|
Ngoensawat U, Pisuchpen T, Sritana-Anant Y, Rodthongkum N, Hoven VP. Conductive electrospun composite fibers based on solid-state polymerized Poly(3,4-ethylenedioxythiophene) for simultaneous electrochemical detection of metal ions. Talanta 2022; 241:123253. [PMID: 35121539 DOI: 10.1016/j.talanta.2022.123253] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Revised: 01/17/2022] [Accepted: 01/19/2022] [Indexed: 01/16/2023]
Abstract
Conductive composite fibers containing poly (3,4-ethylenedioxythiophene) (PEDOT) and silver nanoparticles (AgNPs) were fabricated by emulsion electrospinning of 2,5-dibromo-3,4-ethylenedioxythiophene (DBEDOT) in toluene together with aqueous solution of poly (vinyl alcohol) (PVA) and silver nanoparticles (AgNPs) in the presence of sodium dodecylsulfate followed by heat treatment at 70 °C to convert DBEDOT to conductive PEDOT via solid state polymerization (SSP). The composite fibers were characterized by scanning electron microscopy, transmission electron microscopy, x-ray photoelectron spectroscopy and thermogravimetric analysis. The PEDOT/PVA/AgNPs composite fibers deposited on a screen-printed carbon electrode (SPCE) surface exhibited good electrochemical response and was applied for simultaneous detection of heavy metal ions in a mixture, namely Zn(II), Cd(II), and Pb(II) via square wave anodic stripping voltammetry (SWASV). With added Bi+3 into the detection system, the bismuth film formed on the electrode allows effective alloy formation with the deposited heavy metals obtained upon reduction of the heavy metal ions, the detection of heavy metal ions after stripping was successfully accomplished with a linear range of 10-80 ppb and limits of detections (LOD) of 6, 3 and 8 ppb for Zn(II), Cd(II), and Pb(II), respectively.
Collapse
Affiliation(s)
- Umphan Ngoensawat
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand
| | - Thanarath Pisuchpen
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand
| | - Yongsak Sritana-Anant
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand
| | - Nadnudda Rodthongkum
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand; Nanotec-CU Center of Excellence on Food and Agriculture, Department of Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand; Center of Excellence in Responsive Wearable Materials, Chulalongkorn University, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand
| | - Voravee P Hoven
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand; Nanotec-CU Center of Excellence on Food and Agriculture, Department of Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand; Center of Excellence in Materials and Biointerfaces, Chulalongkorn University, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand.
| |
Collapse
|
36
|
A new electrochemical aptasensor based on gold/nitrogen-doped carbon nano-onions for the detection of Staphylococcus aureus. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2021.139633] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
37
|
Beitollahi H, Shahsavari M, Sheikhshoaie I, Tajik S, Jahani PM, Mohammadi SZ, Afshar AA. Amplified electrochemical sensor employing screen-printed electrode modified with Ni-ZIF-67 nanocomposite for high sensitive analysis of Sudan I in present bisphenol A. Food Chem Toxicol 2022; 161:112824. [DOI: 10.1016/j.fct.2022.112824] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 01/05/2022] [Accepted: 01/12/2022] [Indexed: 02/07/2023]
|
38
|
Novel screen-printed sensors with chemically deposited boron-doped diamond and their use for voltammetric determination of attention deficit hyperactivity disorder medication atomoxetine. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2021.139642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
39
|
Voltammetric detection of sumatriptan in the presence of naproxen using Fe 3O 4@ZIF-8 nanoparticles modified screen printed graphite electrode. Sci Rep 2021; 11:24068. [PMID: 34912041 PMCID: PMC8674320 DOI: 10.1038/s41598-021-98598-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Accepted: 09/07/2021] [Indexed: 11/28/2022] Open
Abstract
A novel electrochemical sensing platform was designed and prepared for the simultaneous detection of sumatriptan and naproxen by exploiting the prowess of the Fe3O4@ZIF-8 nanoparticles (NPs); as-synthesized Fe3O4@ZIF-8 NPs were characterized by energy-dispersive X-ray spectroscopy, fourier transform infrared spectroscopy, X-ray diffraction, field emission scanning electron microscopy (FESEM), transmission electron microscopy and thermal gravimetric analysis. The immobilized Fe3O4@ZIF-8 NPs on a screen printed graphite electrode (SPGE) was evaluated electrochemically via cyclic voltammetry, linear sweep voltammetry, and differential pulse voltammetry as well as chronoamprometery means; Fe3O4@ZIF-8/SPGE exhibited good sensing performance for sumatriptan in a range of 0.035–475.0 µM with detection limit of 0.012 µM. Also, Fe3O4@ZIF-8/SPGE exhibited good sensing performance for naproxen in a range of 0.1–700.0 µM with detection limit of 0.03 µM. The modified electrode showed two separate oxidative peaks at 620 mV for sumatriptan and at 830 mV for naproxen with a peak potential separation of 210 mV which was large enough to detect the two drugs simultaneously besides being stable in the long-run with considerable reproducibility. Real sample analyses were carried out to identify the function of fabricated electrode in sensing applications wherein trace amounts of sumatriptan and naproxen could be identified in these samples.
Collapse
|
40
|
Marzouk SAM, Alyammahi AR, Fanjul-Bolado P. Development and Characterization of Novel Flow Injection, Thin-Layer, and Batch Cells for Electroanalytical Applications Using Screen-Printed Electrodes. Anal Chem 2021; 93:16690-16699. [PMID: 34851103 DOI: 10.1021/acs.analchem.1c04337] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
In the present paper, the design, fabrication, and analytical applications of three novel cells for flow injection, thin-layer, and batch electrochemical measurements using screen-printed electrode chips (SPECs) are described. Each cell consisted of an acrylic base and a transparent acrylic cover. The essential construction feature of each cell base was a cavity to accommodate the SPEC, whereas the construction features of the clear acrylic cover determined the cell shape and its function. The presented cells offered several common advantages, which include (i) convenient electrical connection of the SPEC to any potentiostat without the need for special cables, (ii) the SPEC was completely contained within the cell body, which eliminated the risk of its breakage, (iii) suitable for use with a large number of commercially available SPECs, and (iv) excellent SPEC sealing. The flow cell offered additional advantages of convenient customization of the cell dead volume and convenient visual inspection of the surface and the vicinity of SPEs. The presented thin-layer cell is the first report on a dedicated cell which realized a near-ideal thin-layer steady-state voltammetry using SPECs. The universal batch cell (UBC) offered extreme versatility and proved suitable for all batch applications in sample volumes ranging from 25 μL to 40 mL with an optional controlled temperature and atmosphere. Moreover, a novel way to achieve stirred-solution chronoamperometry and hydrodynamic voltammetry using SPECs (with superior signal-to-noise ratios) using the UBC is described. Electrochemical measurements to demonstrate the merits and the applicability of all cells are also presented.
Collapse
Affiliation(s)
- Sayed A M Marzouk
- Department of Chemistry, UAE University, P.O. Box 15551 Al Ain, United Arab Emirates
| | - Aisha R Alyammahi
- Department of Chemistry, UAE University, P.O. Box 15551 Al Ain, United Arab Emirates
| | - Pablo Fanjul-Bolado
- Metrohm DropSens S.L., Edificio CEEI-Parque Tecnológico de Asturias, 33428 Llanera, Spain
| |
Collapse
|
41
|
Yang Q, Nagar B, Alvarez-Diduk R, Balsells M, Farinelli A, Bloisi D, Proia L, Espinosa C, Ordeix M, Knutz T, De Vito-Francesco E, Allabashi R, Merkoçi A. Development of a Heavy Metal Sensing Boat for Automatic Analysis in Natural Waters Utilizing Anodic Stripping Voltammetry. ACS ES&T WATER 2021; 1:2470-2476. [PMID: 34918010 PMCID: PMC8669633 DOI: 10.1021/acsestwater.1c00192] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2021] [Revised: 09/29/2021] [Accepted: 09/30/2021] [Indexed: 05/23/2023]
Abstract
Determination of the levels of heavy metal ions would support assessment of sources and pathways of water pollution. However, traditional spatial assessment by manual sampling and off-site detection in the laboratory is expensive and time-consuming and requires trained personnel. Aiming to fill the gap between on-site automatic approaches and laboratory techniques, we developed an autonomous sensing boat for on-site heavy metal detection using square-wave anodic stripping voltammetry. A fluidic sensing system was developed to integrate into the boat as the critical sensing component and could detect ≤1 μg/L Pb, ≤6 μg/L Cu, and ≤71 μg/L Cd simultaneously in the laboratory. Once its integration was completed, the autonomous sensing boat was tested in the field, demonstrating its ability to distinguish the highest concentration of Pb in an effluent of a galena-enriched mine compared to those at other sites in the stream (Osor Stream, Girona, Spain).
Collapse
Affiliation(s)
- Qiuyue Yang
- Nanobioelectronics
and Biosensors Group, Catalan Institute
of Nanoscience and Nanotechnology (ICN2), CSIC, and The Barcelona
Institute of Science and Technology, Campus UAB, Bellaterra, 08193 Barcelona, Spain
- Universitat
Autònoma de Barcelona, Department
of Material Science, Campus
de la UAB, Plaça Cívica, Bellaterra, 08193 Barcelona, Spain
| | - Bhawna Nagar
- Nanobioelectronics
and Biosensors Group, Catalan Institute
of Nanoscience and Nanotechnology (ICN2), CSIC, and The Barcelona
Institute of Science and Technology, Campus UAB, Bellaterra, 08193 Barcelona, Spain
- École
Polytechnique Fédérale de Lausanne (EPFL) Valais Wallis,
Laboratory of Physical and Analytical Electrochemistry, Rue de l’Industrie 17, 1950 Sion, Switzerland
| | - Ruslán Alvarez-Diduk
- Nanobioelectronics
and Biosensors Group, Catalan Institute
of Nanoscience and Nanotechnology (ICN2), CSIC, and The Barcelona
Institute of Science and Technology, Campus UAB, Bellaterra, 08193 Barcelona, Spain
| | - Marc Balsells
- Nanobioelectronics
and Biosensors Group, Catalan Institute
of Nanoscience and Nanotechnology (ICN2), CSIC, and The Barcelona
Institute of Science and Technology, Campus UAB, Bellaterra, 08193 Barcelona, Spain
| | - Alessandro Farinelli
- University
of Verona, Department of Computer
Science, Ca Vignal 2,
Strada le Grazie 15, 37134 Verona, Italy
| | - Domenico Bloisi
- University
of Verona, Department of Computer
Science, Ca Vignal 2,
Strada le Grazie 15, 37134 Verona, Italy
- Department
of Mathematics, Computer Science, and Economics, University of Basilicata, 85100 Potenza, Italy
| | - Lorenzo Proia
- BETA Technological
Center, University of Vic-Central University
of Catalonia (UVic-UCC), 08500 Vic, Spain
| | - Carmen Espinosa
- BETA Technological
Center, University of Vic-Central University
of Catalonia (UVic-UCC), 08500 Vic, Spain
- CERM, Center
for the Study of Mediterranean Rivers, University of Vic-Central University
of Catalonia (UVic-UCC), 08560 Manlleu, Spain
| | - Marc Ordeix
- BETA Technological
Center, University of Vic-Central University
of Catalonia (UVic-UCC), 08500 Vic, Spain
- CERM, Center
for the Study of Mediterranean Rivers, University of Vic-Central University
of Catalonia (UVic-UCC), 08560 Manlleu, Spain
| | - Thorsten Knutz
- Go
Systemelektronik GmbH, Falunerweg 1, D-24109 Kiel, Germany
| | - Elisabetta De Vito-Francesco
- University
of Natural Resources and Life Sciences, Institute for Sanitary Engineering
and Water Pollution Control, Muthgasse 18, 1190 Vienna, Austria
| | - Roza Allabashi
- University
of Natural Resources and Life Sciences, Institute for Sanitary Engineering
and Water Pollution Control, Muthgasse 18, 1190 Vienna, Austria
| | - Arben Merkoçi
- Nanobioelectronics
and Biosensors Group, Catalan Institute
of Nanoscience and Nanotechnology (ICN2), CSIC, and The Barcelona
Institute of Science and Technology, Campus UAB, Bellaterra, 08193 Barcelona, Spain
- ICREA, Pg. Lluís
Companys, 23, Barcelona 08010, Spain
| |
Collapse
|
42
|
Beardsley CA, Fuller KZ, Reilly TH, Henry CS. Method for analysis of environmental lead contamination in soils. Analyst 2021; 146:7520-7527. [PMID: 34806095 DOI: 10.1039/d1an01744f] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A method for lead (Pb) detection in soil is presented. Pb is a dangerous environmental pollutant that is present in soils, posing a health risk to millions of people worldwide, and regular monitoring of Pb contamination in soils is essential to public health. Many sensitive methods for detection of heavy metals in solid matrices exist, but they cannot be performed on-site because they are costly (>$30 per sample), require trained personnel, and many classical sample preparation methods are not safe to bring into the field. We describe an alternative process, combining a safer sample preparation method with electrochemical analysis. The process requires minimal training, making it an attractive overall method for regular environmental screening of Pb in soils. Extract obtained from the soil is pH adjusted and analyzed using a stencil-printed carbon electrode and square wave anodic stripping voltammetry. In this work, a study of 15 neighborhood soils examining the concentration of Pb present post-extraction was performed to demonstrate the method. The limit of detection for the electrochemical analysis was calculated to be 16 ppb-well below the United States Environmental Protection Agency's action limit for Pb in soils (400 mg kg-1 or 4000 ppb)-and third party inductively coupled plasma-optical emission spectroscopy analysis validated the results obtained in this study to within ±17% on average.
Collapse
Affiliation(s)
- Chloe A Beardsley
- Access Sensor Technologies LLC, 320 E. Vine Dr. STE 221, Fort Collins, CO 80524, USA.
| | - Kai Z Fuller
- Access Sensor Technologies LLC, 320 E. Vine Dr. STE 221, Fort Collins, CO 80524, USA.
| | - Thomas H Reilly
- Access Sensor Technologies LLC, 320 E. Vine Dr. STE 221, Fort Collins, CO 80524, USA.
| | - Charles S Henry
- Access Sensor Technologies LLC, 320 E. Vine Dr. STE 221, Fort Collins, CO 80524, USA. .,Department of Chemistry, Colorado State University, 1301 Center Ave., Fort Collins, CO 80523-1872, USA.
| |
Collapse
|
43
|
A sensitive electrochemical analysis for cadmium and lead based on Nafion-Bismuth film in a water sample. SENSING AND BIO-SENSING RESEARCH 2021. [DOI: 10.1016/j.sbsr.2021.100454] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
44
|
Miranda J, Humphrey N, Kinney R, O’Sullivan R, Thomas B, Mondaca Medina IE, Freedman R, Fahrenkrug E. On-Chip Optical Anodic Stripping with Closed Bipolar Cells and Cathodic Electrochemiluminescence Reporting. ACS Sens 2021; 6:4136-4144. [PMID: 34699192 DOI: 10.1021/acssensors.1c01664] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The aim of this work was to develop a simple, accessible, and point-of-use sensor to measure heavy metal ions in water in low-resource areas that cannot accommodate expensive or technical solutions. This report describes a new bipolar electrochemical sensor platform that reimagines conventional anodic stripping voltammetry in a wireless bipolar format with an optical electrochemiluminescent readout that can be quantified with any simple optical sensor like that found on most modern cell phone cameras. We call this technique as optical anodic stripping. Using a new nonlithographic fabrication process, devices could be produced rapidly and simply at <$1/sensor. The sensing scheme was developed, characterized, and optimized using electrochemical and optical methods. Quantitation of Pb2+ in both lab and natural water samples was rapid (2-3 min), accurate, precise, and highly linear in the 25-1000 ppb range and was shown to be sufficiently selective in the presence of other common heavy metal ions such as Cu2+, Cd2+, and Zn2+.
Collapse
Affiliation(s)
- Jeronimo Miranda
- Department of Chemistry & Biochemistry, Colorado College, 14 E. Cache la Poudre Street, Colorado Springs, Colorado 80903, United States
| | - Nicholas Humphrey
- Department of Chemistry & Biochemistry, Colorado College, 14 E. Cache la Poudre Street, Colorado Springs, Colorado 80903, United States
| | - Rowan Kinney
- Department of Chemistry & Biochemistry, Colorado College, 14 E. Cache la Poudre Street, Colorado Springs, Colorado 80903, United States
| | - Riley O’Sullivan
- Department of Chemistry & Biochemistry, Colorado College, 14 E. Cache la Poudre Street, Colorado Springs, Colorado 80903, United States
| | - Bradley Thomas
- Department of Chemistry & Biochemistry, Colorado College, 14 E. Cache la Poudre Street, Colorado Springs, Colorado 80903, United States
| | - Ivan Elias Mondaca Medina
- Department of Chemistry & Biochemistry, Colorado College, 14 E. Cache la Poudre Street, Colorado Springs, Colorado 80903, United States
| | - Ryan Freedman
- Department of Chemistry & Biochemistry, Colorado College, 14 E. Cache la Poudre Street, Colorado Springs, Colorado 80903, United States
| | - Eli Fahrenkrug
- Department of Chemistry & Biochemistry, Colorado College, 14 E. Cache la Poudre Street, Colorado Springs, Colorado 80903, United States
| |
Collapse
|
45
|
Chemical vapor deposition synthesis of high-quality Ni3C/GNPs composite material: Effect of growth time on the yield, morphology and adsorption behavior of metal ions. CHEMICAL PAPERS 2021. [DOI: 10.1007/s11696-021-01962-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
46
|
Shahsavari M, Tajik S, Sheikhshoaie I, Garkani Nejad F, Beitollahi H. Synthesis of Fe3O4@copper(II) imidazolate nanoparticles: Catalytic activity of modified graphite screen printed electrode for the determination of levodopa in presence of melatonin. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106637] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
47
|
Mohamad Nor N, Ramli NH, Poobalan H, Qi Tan K, Abdul Razak K. Recent Advancement in Disposable Electrode Modified with Nanomaterials for Electrochemical Heavy Metal Sensors. Crit Rev Anal Chem 2021; 53:253-288. [PMID: 34565248 DOI: 10.1080/10408347.2021.1950521] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Heavy metal pollution has gained global attention due to its high toxicity and non-biodegradability, even at a low level of exposure. Therefore, the development of a disposable electrode that is sensitive, simple, portable, rapid, and cost-effective as the sensor platform in electrochemical heavy metal detection is vital. Disposable electrodes have been modified with nanomaterials so that excellent electrochemical properties can be obtained. This review highlights the recent progress in the development of numerous types of disposable electrodes modified with nanomaterials for electrochemical heavy metal detection. The disposable electrodes made from carbon-based, glass-based, and paper-based electrodes are reviewed. In particular, the analytical performance, fabrication technique, and integration design of disposable electrodes modified with metal (such as gold, tin and bismuth), carbon (such as carbon nanotube and graphene), and metal oxide (such as iron oxide and zinc oxide) nanomaterials are summarized. In addition, the role of the nanomaterials in improving the electrochemical performance of the modified disposable electrodes is discussed. Finally, the current challenges and future prospect of the disposable electrode modified with nanomaterials are summarized.
Collapse
Affiliation(s)
- Noorhashimah Mohamad Nor
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Nurul Hidayah Ramli
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Hemalatha Poobalan
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Kai Qi Tan
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Khairunisak Abdul Razak
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia.,NanoBiotechnology Research & Innovation (NanoBRI), Institute for Research in Molecular Medicine, Universiti Sains Malaysia, 11800 USM, Pulau Pinang, Malaysia
| |
Collapse
|
48
|
Advancement in Salmonella Detection Methods: From Conventional to Electrochemical-Based Sensing Detection. BIOSENSORS-BASEL 2021; 11:bios11090346. [PMID: 34562936 PMCID: PMC8468554 DOI: 10.3390/bios11090346] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Revised: 09/06/2021] [Accepted: 09/09/2021] [Indexed: 02/07/2023]
Abstract
Large-scale food-borne outbreaks caused by Salmonella are rarely seen nowadays, thanks to the advanced nature of the medical system. However, small, localised outbreaks in certain regions still exist and could possess a huge threat to the public health if eradication measure is not initiated. This review discusses the progress of Salmonella detection approaches covering their basic principles, characteristics, applications, and performances. Conventional Salmonella detection is usually performed using a culture-based method, which is time-consuming, labour intensive, and unsuitable for on-site testing and high-throughput analysis. To date, there are many detection methods with a unique detection system available for Salmonella detection utilising immunological-based techniques, molecular-based techniques, mass spectrometry, spectroscopy, optical phenotyping, and biosensor methods. The electrochemical biosensor has growing interest in Salmonella detection mainly due to its excellent sensitivity, rapidity, and portability. The use of a highly specific bioreceptor, such as aptamers, and the application of nanomaterials are contributing factors to these excellent characteristics. Furthermore, insight on the types of biorecognition elements, the principles of electrochemical transduction elements, and the miniaturisation potential of electrochemical biosensors are discussed.
Collapse
|
49
|
Eswaran M, Tsai PC, Wu MT, Ponnusamy VK. Novel nano-engineered environmental sensor based on polymelamine/graphitic-carbon nitride nanohybrid material for sensitive and simultaneous monitoring of toxic heavy metals. JOURNAL OF HAZARDOUS MATERIALS 2021; 418:126267. [PMID: 34111746 DOI: 10.1016/j.jhazmat.2021.126267] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 05/16/2021] [Accepted: 05/28/2021] [Indexed: 06/12/2023]
Abstract
Heavy metal ions (HMIs) pollution is always a serious issue worldwide. Therefore, monitoring HMIs in environmental water is an important and challenging step to ensure environmental health and human safety. In this study, we spotlight an effortless, single-step in-situ electrochemical polymerization deposition technique to fabricate a novel, low-cost, efficient, nano-engineered poly(melamine)/graphitic-carbon nitride nanonetwork (PM/g-C3N4) modified screen-printed carbon electrode (SPE) for sensitive, selective, and simultaneous electrochemical monitoring of toxic HMIs in environmental waters. g-C3N4 nanomaterial was prepared using melamine as a precursor via pyrolysis technique. As-prepared g-C3N4 and melamine monomer were electrochemically in-situ polymerized/deposited over pre-anodized SPE (ASPE) using cyclic voltammetry technique. XRD, XPS, and SEM were engaged to characterize the developed electrode. The fabricated PM/g-C3N4/ASPE was applied as an environmental sensor to selective and simultaneous electrochemical detection of Pb2+ and Cd2+ ions using differential pulse voltammetry technique. The developed sensor displayed excellent selectivity and sensitivity towards Pb2+ and Cd2+ with limit of detections of 0.008 µM and 0.02 µM, respectively. The fabricated PM/g-C3N4/ASPE sensor exhibits superior stability, repeatability, good anti-interference, and applicability for recognition of Pb2+ and Cd2+ ions in real water samples. These results proved that developed environmental sensor is low-cost, efficient, practical platform for rapid, selective, simultaneous monitoring of HMIs in the environment.
Collapse
Affiliation(s)
- Muthusankar Eswaran
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan
| | - Pei-Chien Tsai
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan
| | - Ming-Tsang Wu
- Research Center for Environmental Medicine, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan; Department of Public Health, College of Health Sciences, Kaohsiung Medical University, Kaohsiung, Taiwan; Department of Family Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Vinoth Kumar Ponnusamy
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan; Research Center for Environmental Medicine, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan; Department of Medical Research, Kaohsiung Medical University Hospital (KMUH), Kaohsiung City 807, Taiwan; Department of Chemistry, National Sun Yat-sen University (NSYSU), Kaohsiung City 804, Taiwan; PhD Program of Aquatic Science and Technology, College of Hydrosphere Science, National Kaohsiung University of Science and Technology (NKUST), Kaohsiung City 807, Taiwan.
| |
Collapse
|
50
|
Ivanov R, Czibula C, Teichert C, Bojinov M, Tsakova V. Carbon screen-printed electrodes for substrate-assisted electroless deposition of palladium. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115617] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|