1
|
Chen T, Zang T, Liang J, Zhou Y, Zhou X. A highly sensitive fluorescence biosensor based on polylysine functionalized quantum dots for serum GDF-15 detection. Talanta 2025; 285:127274. [PMID: 39613492 DOI: 10.1016/j.talanta.2024.127274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2024] [Revised: 11/18/2024] [Accepted: 11/21/2024] [Indexed: 12/01/2024]
Abstract
Growth differentiation factor-15 (GDF-15) is a stress-responsive cytokine that increases in tissue injury and inflammatory states. The circulation level of GDF-15 is firmly correlated with cardiovascular diseases. Herein, we constructed a novel quantum dot-based fluorescent immunosensor for the sensitive detection of serum GDF-15. In this proposed platform, green-emission water-soluble carboxyl-capped CdTe quantum dots were synthesized as fluorescent labels, conjugated with lysine-rich biotinylated peptides P16K to amplify fluorescent signals, and then linked to antibodies via a biotin-streptavidin system to obtain the fluorescent detection probes. The probes were then integrated into a fluorescence-linked immunosorbent assay (FLISA) platform for GDF-15 detection, achieving a wide linear range (6-1600 pg/mL) and low limits of detection (0.98 pg/mL). Moreover, our approach has been demonstrated in clinical validation experiments performed on human serum samples, in which the results obtained were consistent with those from commercial ELISA kits. Due to its higher sensitivity in comparison to commercial ELISA kits, the platform shows excellent potential for early diagnosis and risk screening of cardiovascular diseases.
Collapse
Affiliation(s)
- Tongfang Chen
- School of Pharmaceutical Sciences, Sun Yat-sen University, Guangzhou, 510006, China
| | - Ting Zang
- The First Clinical Medical College and the First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, 510006, China
| | - Jingjie Liang
- School of Pharmaceutical Sciences, Sun Yat-sen University, Guangzhou, 510006, China
| | - Yingchun Zhou
- The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, 510405, China; Baiyun Hospital of The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, 510470, China.
| | - Xie Zhou
- School of Pharmaceutical Sciences, Sun Yat-sen University, Guangzhou, 510006, China.
| |
Collapse
|
2
|
Dede M, van Dam A. Conjugation of visual enhancers in lateral flow immunoassay for rapid forensic analysis: A critical review. Anal Bioanal Chem 2025; 417:15-31. [PMID: 39384571 PMCID: PMC11695493 DOI: 10.1007/s00216-024-05565-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2024] [Revised: 09/10/2024] [Accepted: 09/23/2024] [Indexed: 10/11/2024]
Abstract
During crime scene investigations, numerous traces are secured and may be used as evidence for the evaluation of source and/or activity level propositions. The rapid chemical analysis of a biological trace enables the identification of body fluids and can provide significant donor profiling information, including age, sex, drug abuse, and lifestyle. Such information can be used to provide new leads, exclude from, or restrict the list of possible suspects during the investigative phase. This paper reviews the state-of-the-art labelling techniques to identify the most suitable visual enhancer to be implemented in a lateral flow immunoassay setup for the purpose of trace identification and/or donor profiling. Upon comparison, and with reference to the strengths and limitations of each label, the simplistic one-step analysis of noncompetitive lateral flow immunoassay (LFA) together with the implementation of carbon nanoparticles (CNPs) as visual enhancers is proposed for a sensitive, accurate, and reproducible in situ trace analysis. This approach is versatile and stable over different environmental conditions and external stimuli. The findings of the present comparative analysis may have important implications for future forensic practice. The selection of an appropriate enhancer is crucial for a well-designed LFA that can be implemented at the crime scene for a time- and cost-efficient investigation.
Collapse
Affiliation(s)
- Maria Dede
- Department Biomedical Engineering & Physics, Amsterdam UMC, University of Amsterdam, Meibergdreef 9, Amsterdam, 1105 AZ, Netherlands.
- Methodology Research Program, Amsterdam Public Health Research Institute, Amsterdam UMC, Meibergdreef 9, Amsterdam, 1105 AZ, Netherlands.
| | - Annemieke van Dam
- Department Biomedical Engineering & Physics, Amsterdam UMC, University of Amsterdam, Meibergdreef 9, Amsterdam, 1105 AZ, Netherlands
- Department Forensic Science, Amsterdam University of Applied Sciences, Tafelbergweg 51, Amsterdam, 1105 BD, Netherlands
- Methodology Research Program, Amsterdam Public Health Research Institute, Amsterdam UMC, Meibergdreef 9, Amsterdam, 1105 AZ, Netherlands
| |
Collapse
|
3
|
Tang X, Xia W, Han H, Wang Y, Wang B, Gao S, Zhang P. Dual-Fluorescent Quantum Dot Nanobead-Based Lateral Flow Immunoassay for Simultaneous Detection of C-Reactive Protein and Procalcitonin. ACS APPLIED BIO MATERIALS 2024; 7:7659-7665. [PMID: 39482872 DOI: 10.1021/acsabm.4c01230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2024]
Abstract
Simultaneous detection of C-reactive protein (CRP) and procalcitonin (PCT) at the point of care is crucial for the management of infections in patients with inflammation and in critical care settings. The challenge of detecting high concentrations of CRP alongside low concentrations of PCT in plasma from inflammatory patients has limited the clinical application of multiplexed immunoassays. Herein, we developed a lateral flow immunoassay (LFIA) that employs quantum dot nanobeads (QDNBs) of varying sizes and colors to enable the simultaneous quantification of PCT and CRP in human plasma. To extend the dynamic range of CRP detection, we combined QDNBs with smaller particle sizes with the CRP detection antibodies, thereby increasing the assay's dynamic range and reducing the hook effect. At the same time, the stronger fluorescence emitted by these larger QDNBs, in conjugation with the PCT detection antibodies, allows for the detection of PCT at the nanogram level, meeting the demand for high sensitivity. The results show that this method can detect CRP concentrations from 0.1 to 3 mg/L and PCT with a detection limit of 0.09 ng/mL, which is on par with clinically used methods. By employing this dual-color and dual-size QDNB labeling strategy, we successfully achieved simultaneous detection of CRP with a broad dynamic range and PCT with high sensitivity in a one-step point-of-care rapid test.
Collapse
Affiliation(s)
- Xinyue Tang
- Department of Central Laboratory, Shanghai Skin Disease Hospital, School of Medicine, Tongji University, Shanghai 200443, China
- College of Chemistry and Biological Engineering, Yichun University, Yichun, Jiangxi 336000, China
| | - Wenwen Xia
- Department of Pharmacy, Changzheng Hospital, Naval Medical University, Shanghai 200003, China
- College of Traditional Chinese Medicine, Yunnan University of Traditional Chinese Medicine, Kunming, Yunnan 650500, China
| | - Huanxing Han
- Department of Pharmacy, Changzheng Hospital, Naval Medical University, Shanghai 200003, China
| | - Yucheng Wang
- Shanghai Kundao Biotech Inc., Shanghai 201201, China
| | - Bolong Wang
- College of Chemistry and Biological Engineering, Yichun University, Yichun, Jiangxi 336000, China
| | - Shouhong Gao
- Department of Pharmacy, Changzheng Hospital, Naval Medical University, Shanghai 200003, China
- College of Traditional Chinese Medicine, Yunnan University of Traditional Chinese Medicine, Kunming, Yunnan 650500, China
| | - Pengfei Zhang
- Department of Central Laboratory, Shanghai Skin Disease Hospital, School of Medicine, Tongji University, Shanghai 200443, China
| |
Collapse
|
4
|
Li W, Yang X, Wang D, Xie J, Wang S, Rong Z. A handheld fluorescent lateral flow immunoassay platform for highly sensitive point-of-care detection of methamphetamine and tramadol. Talanta 2024; 277:126438. [PMID: 38897012 DOI: 10.1016/j.talanta.2024.126438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 05/23/2024] [Accepted: 06/14/2024] [Indexed: 06/21/2024]
Abstract
The escalating issue of drug abuse poses a significant threat to public health and societal stability worldwide. An on-site drug detection platform is vital for combating drug abuse and trafficking, as it eliminates the need for additional tools, extensive processes, or specialized training. Therefore, it is imperative to develop a fast, sensitive, non-invasive, and reliable multiplex drug testing platform. In this study, we have presented a silica core@dual quantum dot-shell nanocomposite (SI/DQD)-based fluorescent lateral flow immunoassay (LFIA) platform for the highly sensitive and simultaneous point-of-care (POC) detection of methamphetamine (MET) and tramadol (TR). A 3D-printed attachment was designed to integrate optical and electrical components, facilitating the miniaturization of the instrument and reducing both cost and complexity. The device's advanced hardware and effective fluorescence extraction algorithm with waveform reconstruction enable swift, automatic noise reduction and data analysis. SI/DQD nanocomposites were utilized as fluorescent nanotags in the LFIA strips due to their outstanding luminous efficiency and robustness. This LFIA platform achieves impressive detection limits (LODs) of 0.11 ng mL-1 for MET and 0.017 ng mL-1 for TR. The method has also successfully detected MET and TR in complex biological samples, demonstrating its practical application capabilities. The proposed fluorescent LFIA platform, based on SI/DQD technology, holds significant promise for the swift and accurate POC detection of these substances. Its affordability, compact size, and excellent analytical performance make it suitable for on-site drug testing, including at borders and roadside checks, and open up new possibilities for the design and implementation of drug testing methods.
Collapse
Affiliation(s)
- Weijia Li
- State Key Laboratory of Toxicology and Medical Countermeasures, and Laboratory of Toxicant Analysis, Institute of Toxicology and Pharmacology, Beijing, 100850, China
| | | | - Dongfeng Wang
- Bioinformatics Center of AMMS, Beijing, 100850, China
| | - Jianwei Xie
- State Key Laboratory of Toxicology and Medical Countermeasures, and Laboratory of Toxicant Analysis, Institute of Toxicology and Pharmacology, Beijing, 100850, China.
| | - Shengqi Wang
- Bioinformatics Center of AMMS, Beijing, 100850, China.
| | - Zhen Rong
- Bioinformatics Center of AMMS, Beijing, 100850, China.
| |
Collapse
|
5
|
Shao X, Dong Z, Zhang S, Qiao Y, Zhang H, Guo H. Quantum dots-based multiplexed immunosensors for accurate diagnosis of attention deficit hyperactivity disorder in childhood. J Pharm Biomed Anal 2024; 243:116096. [PMID: 38484638 DOI: 10.1016/j.jpba.2024.116096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 03/04/2024] [Accepted: 03/06/2024] [Indexed: 04/06/2024]
Abstract
Attention-deficit/hyperactivity disorder (ADHD) lacks objective diagnostic markers. In clinical settings, reliance on subjective judgments can often lead to missed or misdiagnoses. Some biomarkers have been reported to be associated with ADHD, but using one biomarker alone is not enough. To address this, we developed a fluorescent immunoassay platform based on quantum dots (QDs) to detect assay capable of detecting and quantifying multiple biomarkers simultaneously. Specifically, we were able to the simultaneously detect brain-derived neurotrophic factor, tumor necrosis factor-alpha, interleukin-6 and ferritin using different emission spectra QDs. The QD-based multiplexed immunoassay displayed a low detection of limit in the range of 0.021-0.068 pg/mL, and the assay showed satisfactory reproducibility and precision. We then quantified all four targets from ADHD patient's plasma samples, where it showed remarkable consistency with clinical test for ADHD diagnosis. This methodological comparison supports the diagnosis of ADHD using our assay.
Collapse
Affiliation(s)
- Xinyue Shao
- Zhumadian Second People's Hospital, Zhumadian, Henan 463000, China.
| | - Zhao Dong
- Zhumadian Second People's Hospital, Zhumadian, Henan 463000, China
| | - Shuai Zhang
- Zhumadian Second People's Hospital, Zhumadian, Henan 463000, China
| | - Yunyun Qiao
- Zhumadian Second People's Hospital, Zhumadian, Henan 463000, China
| | - Hongwei Zhang
- Zhumadian Second People's Hospital, Zhumadian, Henan 463000, China
| | - Hua Guo
- Zhumadian Second People's Hospital, Zhumadian, Henan 463000, China
| |
Collapse
|
6
|
Zhao J, Han H, Liu Z, Chen J, Liu X, Sun Y, Wang B, Zhao B, Pang Y, Xiao R. Portable fluorescent lateral flow assay for ultrasensitive point-of-care analysis of acute myocardial infarction related microRNA. Anal Chim Acta 2024; 1295:342306. [PMID: 38355230 DOI: 10.1016/j.aca.2024.342306] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 01/02/2024] [Accepted: 01/29/2024] [Indexed: 02/16/2024]
Abstract
Point-of-care quantitative analysis of tracing microRNA disease-biomarkers remains a great challenge in the clinical diagnosis. In this paper, we developed a portable fluorescent lateral flow assay for ultrasensitive quantified detection of acute myocardial infarction related microRNAs in bio-samples. SiO2@DQD (bilayer quantum dots assembly with SiO2 core) based fluorescent lateral flow strip was fabricated as the analysis tool. In order to quantify the tracing microRNA in biosamples, a catalytic hairpin assembly and CRISPR/Cas12a cascade amplification method was performed and combined with the fabricated SiO2@DQD lateral flow strip. Thus, our platform gathered double advantages of portability and ultrasensitive quantification. Based on our strips, target myocardial biomarker microRNA-133a can be detected with a detection limit of 0.32 fM, which was almost 1000-fold sensitive compared with previous reported microRNAs-lateral flow strips. Significantly, this portable fluorescent strip can directly detect microRNAs in serum without any pretreatment and PCR amplification steps. When spiked in serum samples, a recovery of 99.65 %-102.38 % can be obtained. Therefore, our method offers a potential tool for ultrasensitive quantification of diseases related microRNA in the point-of-care diseases diagnosis field.
Collapse
Affiliation(s)
- Junnan Zhao
- College of Life Science, Hebei Normal University, Shijiazhuang, 050024, PR China; State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Han Han
- College of Life Science, Hebei Normal University, Shijiazhuang, 050024, PR China; State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Zhenzhen Liu
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Jin Chen
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Xiaoxian Liu
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Yinuo Sun
- College of Life Science, Hebei Normal University, Shijiazhuang, 050024, PR China; State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Bingwei Wang
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Baohua Zhao
- College of Life Science, Hebei Normal University, Shijiazhuang, 050024, PR China.
| | - Yuanfeng Pang
- Department of Toxicology, Capital Medical University, No. 10 Xitoutiao, You An Men, Beijing, 100069, PR China.
| | - Rui Xiao
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China.
| |
Collapse
|
7
|
Lv Y, Li N, Wang L, Fan J, Xing H, Shi Y, Yu S, Wu R, Shen H, Li LS. Tailored three-color quantum dots nanobeads for multiplexed detection with tunable detection range and multilevel sensitivity of signal-amplified immunosensor. Talanta 2024; 269:125416. [PMID: 38000240 DOI: 10.1016/j.talanta.2023.125416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Revised: 11/07/2023] [Accepted: 11/14/2023] [Indexed: 11/26/2023]
Abstract
The excellent optical properties of quantum dots (QDs) make them as an ideal fluorescent probe for multiplexed detection, however, the interference between different emission spectra, the dependence of excitation wavelengths, and the sharp decrease of quantum yield (QY) during surface modification are issues that cannot be ignored. Herein, a dual protection scheme of polymer and silica was proposed to prepare high-quality three-color QDs nanobeads using QDs with different ligands. In comparison with single-core QDs, the fluorescence signal of the prepared QD nanobeads (QBs) is increased by more than 1,000 times and has better stability. Considering the excitation efficiency of QDs, we tailor three-color QBs as fluorescent probes based on fluorescence-linked immunosorbent assays (tQBs-FLISA) to detect multiple inflammatory biomarkers simultaneously with tunable detection ranges. This resulted in highly sensitive detection of three inflammatory biomarkers in comparison to the single-core QD-FLISA, the sensitivities of C-reactive protein (CRP), serum amyloid A (SAA), and procalcitonin (PCT) were increased by 16-fold, 19-fold, and 5-fold, respectively, to 0.48 ng/mL, 0.42 ng/mL, and 10 pg/mL. Furthermore, the tQBs-FLISA showed good accuracy without interference from common serum factors. In this strategy, a three-color QBs suitable for multilevel sensitivity and tunable detection range was tailored using the versatile polymer and silica dual protection method, building high-performance immunosensor for in vitro diagnostics (IVD).
Collapse
Affiliation(s)
- Yanbing Lv
- Key Lab for Special Functional Materials of Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China.
| | - Ning Li
- Key Lab for Special Functional Materials of Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China
| | - Lei Wang
- Key Lab for Special Functional Materials of Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China
| | - Jinjin Fan
- Key Lab for Special Functional Materials of Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China
| | - Huanhuan Xing
- Key Lab for Special Functional Materials of Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China
| | - Yangchao Shi
- Key Lab for Special Functional Materials of Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China
| | - Shenping Yu
- Key Lab for Special Functional Materials of Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China
| | - Ruili Wu
- Key Lab for Special Functional Materials of Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China.
| | - Huaibin Shen
- Key Lab for Special Functional Materials of Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China
| | - Lin Song Li
- Key Lab for Special Functional Materials of Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China.
| |
Collapse
|
8
|
Gordón Pidal JM, Arruza L, Moreno-Guzmán M, López MÁ, Escarpa A. Micromotor-based dual aptassay for early cost-effective diagnosis of neonatal sepsis. Mikrochim Acta 2024; 191:106. [PMID: 38240873 PMCID: PMC10798920 DOI: 10.1007/s00604-023-06134-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2023] [Accepted: 12/11/2023] [Indexed: 01/22/2024]
Abstract
Given the long-life expectancy of the newborn, research aimed at improving sepsis diagnosis and management in this population has been recognized as cost-effective, which at early stages continues to be a tremendous challenge. Despite there is not an ideal-specific biomarker, the simultaneous detection of biomarkers with different behavior during an infection such as procalcitonin (PCT) as high specificity biomarker with one of the earliest biomarkers in sepsis as interleukin-6 (IL-6) increases diagnostic performance. This is not only due to their high positive predictive value but also, since it can also help the clinician to rule out infection and thus avoid the use of antibiotics, due to their high negative predictive value. To this end, we explore a cutting-edge micromotor (MM)-based OFF-ON dual aptassay for simultaneous determination of both biomarkers in 15 min using just 2 μL of sample from low-birth-weight neonates with gestational age less than 32 weeks and birthweight below 1000 g with clinical suspicion of late-onset sepsis. The approach reached the high sensitivities demanded in the clinical scenario (LODPCT = 0.003 ng/mL, LODIL6 = 0.15 pg/mL) with excellent correlation performance (r > 0.9990, p < 0.05) of the MM-based approach with the Hospital method for both biomarkers during the analysis of diagnosed samples and reliability (Er < 6% for PCT, and Er < 4% for IL-6). The proposed approach also encompasses distinctive technical attributes in a clinical scenario since its minimal sample volume requirements and expeditious results compatible with few easy-to-obtain drops of heel stick blood samples from newborns admitted to the neonatal intensive care unit. This would enable the monitoring of both sepsis biomarkers within the initial hours after the manifestation of symptoms in high-risk neonates as a valuable tool in facilitating prompt and well-informed decisions about the initiation of antibiotic therapy.These results revealed the asset behind micromotor technology for multiplexing analysis in diagnosing neonatal sepsis, opening new avenues in low sample volume-based diagnostics.
Collapse
Affiliation(s)
- José M Gordón Pidal
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, Ctra. Madrid-Barcelona, Km. 33.600, Alcalá de Henares, 28802, Madrid, Spain
| | - Luis Arruza
- Department of Neonatology, Instituto del Niño y del Adolescente, Hospital Clínico San Carlos-IdISSC, 28040, Madrid, Spain
| | - María Moreno-Guzmán
- Department of Chemistry in Pharmaceutical Sciences, Analytical Chemistry, Faculty of Pharmacy, Complutense University of Madrid, Plaza Ramón y Cajal, S/N, 28040, Madrid, Spain
| | - Miguel Ángel López
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, Ctra. Madrid-Barcelona, Km. 33.600, Alcalá de Henares, 28802, Madrid, Spain.
- Chemical Research Institute "Andrés M. Del Rio", University of Alcalá, Madrid, Spain.
| | - Alberto Escarpa
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, Ctra. Madrid-Barcelona, Km. 33.600, Alcalá de Henares, 28802, Madrid, Spain.
- Chemical Research Institute "Andrés M. Del Rio", University of Alcalá, Madrid, Spain.
| |
Collapse
|
9
|
Belal F, Mabrouk M, Hammad S, Ahmed H, Barseem A. Recent Applications of Quantum Dots in Pharmaceutical Analysis. J Fluoresc 2024; 34:119-138. [PMID: 37222883 DOI: 10.1007/s10895-023-03276-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Accepted: 05/16/2023] [Indexed: 05/25/2023]
Abstract
Nanotechnology has emerged as one of the most potential areas for pharmaceutical analysis. The need for nanomaterials in pharmaceutical analysis is comprehended in terms of economic challenges, health and safety concerns. Quantum dots (QDs)or colloidal semiconductor nanocrystals are new groups of fluorescent nanoparticles that bind nanotechnology to drug analysis. Because of their special physicochemical characteristics and small size, QDs are thought to be promising candidates for the electrical and luminescent probes development. They were originally developed as luminescent biological labels, but are now discovering new analytical chemistry applications, where their photo-luminescent properties are used in pharmaceutical, clinical analysis, food quality control and environmental monitoring. In this review, we discuss QDs regarding properties and advantages, advances in methods of synthesis and their recent applications in drug analysis in the recent last years.
Collapse
Affiliation(s)
- Fathalla Belal
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, 35516, Egypt
| | - Mokhtar Mabrouk
- Department of pharmaceutical analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, Egypt
| | - Sherin Hammad
- Department of pharmaceutical analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, Egypt
| | - Hytham Ahmed
- Pharmaceutical Analysis Department, Faculty of Pharmacy, Menoufia University, Menoufia, Egypt
| | - Aya Barseem
- Pharmaceutical Analysis Department, Faculty of Pharmacy, Menoufia University, Menoufia, Egypt.
| |
Collapse
|
10
|
Chai F, Wang D, Shi F, Zheng W, Zhao X, Chen Y, Mao C, Zhang J, Jiang X. Dual Functional Ultrasensitive Point-of-Care Clinical Diagnosis Using Metal-Organic Frameworks-Based Immunobeads. NANO LETTERS 2023; 23:9056-9064. [PMID: 37738391 DOI: 10.1021/acs.nanolett.3c02828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/24/2023]
Abstract
Sepsis is an acute systemic infectious syndrome with high fatality. Fast and accurate diagnosis, monitoring, and medication of sepsis are essential. We exploited the fluorescent metal-AIEgen frameworks (MAFs) and demonstrated the dual functions of protein detection and bacteria identification: (i) ultrasensitive point-of-care (POC) detection of sepsis biomarkers (100 times enhanced sensitivity); (ii) rapid POC identification of Gram-negative/positive bacteria (selective aggregation within 20 min). Fluorescent lateral flow immunoassays (LFAs) are convenient and inexpensive for POC tests. MAFs possess a large surface area, excellent photostability, high quantum yield (∼80%), and multiple active sites serving as protein binding domains for ultrasensitive detection of sepsis biomarkers (IL-6/PCT) on LFAs. The limit of detection (LOD) for IL-6/PCT is 0.252/0.333 pg/mL. Rapid appraisal of infectious bacteria is vital to guide the use of medicines. The dual-functional fluorescent MAFs have great potential in POC tests for the clinical diagnosis of bacterial infections.
Collapse
Affiliation(s)
- Fengli Chai
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
| | - Dou Wang
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
| | - Fei Shi
- Shenzhen People's Hospital (The First Affiliated Hospital of Southern University of Science and Technology, The Second Clinical Medical College of Jinan University), Shenzhen, Guangdong 518020, China
| | - Wenfu Zheng
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Laboratory for Biological Effects of Nanomaterials and Nanosafety, National Center for NanoScience and Technology, Beijing 100190, China
| | - Xiaohui Zhao
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
| | - Yao Chen
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
| | - Cuiping Mao
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
| | - Jiangjiang Zhang
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
- Key Laboratory of Molecular Medicine and Biotherapy, the Ministry of Industry and Information Technology, School of Life Science, Beijing Institute of Technology, Beijing 100081, China
| | - Xingyu Jiang
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
| |
Collapse
|
11
|
Liu Y, Lv Y, Chen W, Yang X, Cheng X, Rong Z, Wang S. Development of a Fluorescent Immunochromatographic Assay Based on Quantum Dot-Functionalized Two-Dimensional Monolayer Ti 3C 2 MXene Nanoprobes for the Simultaneous Detection of Influenza A Virus and SARS-CoV-2. ACS APPLIED MATERIALS & INTERFACES 2023; 15:35872-35883. [PMID: 37467383 DOI: 10.1021/acsami.3c05424] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/21/2023]
Abstract
Accurate and rapid detection of the influenza A virus (FluA) and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can effectively control their spread. We developed a colorimetric and fluorescent dual-functional two-channel immunochromatographic assay (ICA) biosensor to simultaneously detect the above-mentioned viruses. A unique two-dimensional Ti3C2-QD immunoprobe was established by adsorbing dense quantum dots (QDs) onto the light green monostromatic Ti3C2 MXene surface, resulting in light green colorimetric and superior fluorescence signals and guaranteeing high sensitivity, stability, and excellent liquidity for ICA detection. Rapid visual screening for FluA and SARS-CoV-2 infections was applicable via a green colorimetric signal. Sensitive and quantitative detection of viruses in their early stages of infection was performed by using the fluorescence signal. Our proposed Ti3C2-QD-ICA biosensor can simultaneously detect 1 ng/mL or 2.4 pg/mL FluA and 1 ng/mL or 6.2 pg/mL SARS-CoV-2 via its colorimetric or fluorescence signals, respectively, with a short testing time (20 min), good reproducibility, specificity, and accuracy. In addition, this method demonstrated sensitivity higher than that of the conventional AuNP-based ICA method in throat swab samples. Hence, our proposed Ti3C2-QD-ICA method can be potentially applied for the rapid, ultrasensitive, and multiplex detection of respiratory viruses.
Collapse
Affiliation(s)
- Ye Liu
- Bioinformatics Center of AMMS, Beijing 100850, P. R. China
| | - Yue Lv
- The Third Department of Health Care, the Second Medical Center & National Clinical Research Center for Geriatric Diseases, Chinese PLA General Hospital, Beijing 100089, P. R. China
| | - Wenji Chen
- Bioinformatics Center of AMMS, Beijing 100850, P. R. China
| | - Xingsheng Yang
- Bioinformatics Center of AMMS, Beijing 100850, P. R. China
| | - Xiaodan Cheng
- Bioinformatics Center of AMMS, Beijing 100850, P. R. China
| | - Zhen Rong
- Bioinformatics Center of AMMS, Beijing 100850, P. R. China
| | - Shengqi Wang
- Bioinformatics Center of AMMS, Beijing 100850, P. R. China
| |
Collapse
|
12
|
Zhang X, Li L, Zhang M, Zhang L, Liu S, Guo J, Jiang N, Peng Q, Wang J, Ding S. Intelligent recognition of CTCs from gallbladder cancer by ultrasensitive electrochemical cytosensor and diagnosis of chemotherapeutic resistance. Biosens Bioelectron 2023; 228:115183. [PMID: 36905863 DOI: 10.1016/j.bios.2023.115183] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2022] [Revised: 02/21/2023] [Accepted: 02/25/2023] [Indexed: 03/03/2023]
Abstract
Gallbladder carcinoma (GBC) is one of most aggressive and lethal malignancies. Early diagnosis of GBC is crucial for determining appropriate treatment and improving chances of cure. Chemotherapy represents the main therapeutic regimen for unresectable GBC patients to inhibit tumor growth & metastasis. But, chemoresistance is the major cause of GBC recurrence. Thus, there is an urgent need to explore potentially non-invasive and point-of-care approaches to screen GBC and monitor their chemoresistance. Herein, we established an electrochemical cytosensor to specifically detect circulating tumor cells (CTCs) and their chemoresistance. Trilayer of CdSe/ZnS quantum dots (QDs) were cladded upon SiO2 nanoparticles (NPs), forming Tri-QDs/PEI@SiO2 electrochemical probes. Upon conjugation of anti-ENPP1, the electrochemical probes were able to specifically label captured CTCs from GBC. The detection of CTCs and chemoresistance were realized by square wave anodic stripping voltammetric (SWASV) responses to anodic stripping current of Cd 2+ ion when cadmium in electrochemical probes was dissolved and eventually electrodeposited on bismuth film-modified glassy carbon electrode (BFE). Taking use of this cytosensor, one ensured the screening of GBC and limit of detection for CTCs approaches to ~10 cells/mL. Furthermore, by monitoring phenotypic changes of CTCs after drug treatment, the diagnosis of chemoresistance was achieved by our cytosensor.
Collapse
Affiliation(s)
- Xiuzhen Zhang
- School of Basic Medical Science, Chongqing Medical University, Chongqing, 400016, PR China
| | - Lu Li
- School of Basic Medical Science, Chongqing Medical University, Chongqing, 400016, PR China
| | - Mi Zhang
- Department of Neurosurgery, Children's Hospital of Chongqing Medical University, Chongqing, 400016, PR China
| | - La Zhang
- Department of Hepatobiliary Surgery, Chongqing Medical University, Chongqing, 400016, PR China
| | - Shanshan Liu
- Department of Hepatobiliary Surgery, Chongqing Medical University, Chongqing, 400016, PR China
| | - Jiao Guo
- School of Basic Medical Science, Chongqing Medical University, Chongqing, 400016, PR China
| | - Ning Jiang
- Department of Pathology, Chongqing Medical University, Chongqing, 400016, PR China; Molecular Medicine Diagnostic and Testing Center, Chongqing Medical University, Chongqing, 400016, PR China; Department of Pathology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, PR China.
| | - Qiling Peng
- School of Basic Medical Science, Chongqing Medical University, Chongqing, 400016, PR China.
| | - Jianwei Wang
- School of Basic Medical Science, Chongqing Medical University, Chongqing, 400016, PR China.
| | - Shijia Ding
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine, Chongqing Medical University, Chongqing, 400016, PR China
| |
Collapse
|
13
|
Hou F, Sun S, Abdullah SW, Tang Y, Li X, Guo H. The application of nanoparticles in point-of-care testing (POCT) immunoassays. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:2154-2180. [PMID: 37114768 DOI: 10.1039/d3ay00182b] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
The Covid-19 pandemic has led to greater recognition of the importance of the fast and timely detection of pathogens. Recent advances in point-of-care testing (POCT) technology have shown promising results for rapid diagnosis. Immunoassays are among the most extensive POCT assays, in which specific labels are used to indicate and amplify the immune signal. Nanoparticles (NPs) are above the rest because of their versatile properties. Much work has been devoted to NPs to find more efficient immunoassays. Herein, we comprehensively describe NP-based immunoassays with a focus on particle species and their specific applications. This review describes immunoassays along with key concepts surrounding their preparation and bioconjugation to show their defining role in immunosensors. The specific mechanisms, microfluidic immunoassays, electrochemical immunoassays (ELCAs), immunochromatographic assays (ICAs), enzyme-linked immunosorbent assays (ELISA), and microarrays are covered herein. For each mechanism, a working explanation of the appropriate background theory and formalism is articulated before examining the biosensing and related point-of-care (POC) utility. Given their maturity, some specific applications using different nanomaterials are discussed in more detail. Finally, we outline future challenges and perspectives to give a brief guideline for the development of appropriate platforms.
Collapse
Affiliation(s)
- Fengping Hou
- State Key Laboratory of Veterinary Etiological Biology, OIE/China National Foot-and-Mouth Disease Reference Laboratory, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Xujiaping 1, Lanzhou 730046, Gansu, P. R. China.
- Lanzhou Institute of Biological Products Co., Ltd (LIBP), Subsidiary Company of China National Biotec Group Company Limited (CNBG), 730046 Lanzhou, China.
| | - Shiqi Sun
- State Key Laboratory of Veterinary Etiological Biology, OIE/China National Foot-and-Mouth Disease Reference Laboratory, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Xujiaping 1, Lanzhou 730046, Gansu, P. R. China.
| | - Sahibzada Waheed Abdullah
- State Key Laboratory of Veterinary Etiological Biology, OIE/China National Foot-and-Mouth Disease Reference Laboratory, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Xujiaping 1, Lanzhou 730046, Gansu, P. R. China.
| | - Yu Tang
- State Key Laboratory of Applied Organic Chemistry, Key Laboratory of Nonferrous Metal Chemistry and Resources Utilization of Gansu Province, College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou 730000, Gansu, P. R. China
| | - Xiongxiong Li
- Lanzhou Institute of Biological Products Co., Ltd (LIBP), Subsidiary Company of China National Biotec Group Company Limited (CNBG), 730046 Lanzhou, China.
| | - Huichen Guo
- State Key Laboratory of Veterinary Etiological Biology, OIE/China National Foot-and-Mouth Disease Reference Laboratory, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Xujiaping 1, Lanzhou 730046, Gansu, P. R. China.
- State Key Laboratory for Animal Disease Control and Prevention, College of Veterinary Medicine, Lanzhou University, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Lanzhou 730000, P. R. China
| |
Collapse
|
14
|
Lv Y, Fan J, Zhao M, Wu R, Li LS. Recent advances in quantum dot-based fluorescence-linked immunosorbent assays. NANOSCALE 2023; 15:5560-5578. [PMID: 36866747 DOI: 10.1039/d2nr07247e] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Fluorescence immunoassays have been given considerable attention among the quantitative detection methods in the clinical medicine and food safety testing fields. In particular, semiconductor quantum dots (QDs) have become ideal fluorescent probes for highly sensitive and multiplexed detection due to their unique photophysical properties, and the QD fluorescence-linked immunosorbent assay (FLISA) with high sensitivity, high accuracy, and high throughput has been greatly developed recently. In this manuscript, the advantages of applying QDs to FLISA platforms and some strategies for their application to in vitro diagnostics and food safety are discussed. Given the rapid development of this field, we classify these strategies based on the combination of QD types and detection targets, including traditional QDs or QD micro/nano-spheres-FLISA, and multiple FLISA platforms. In addition, some new sensors based on the QD-FLISA are introduced; this is one of the hot spots in this field. The current focus and future direction of QD-FLISA are also discussed, which provides important guidance for the further development of FLISA.
Collapse
Affiliation(s)
- Yanbing Lv
- Key Lab for Special Functional Materials of the Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China.
| | - Jinjin Fan
- Key Lab for Special Functional Materials of the Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China.
| | - Man Zhao
- Key Lab for Special Functional Materials of the Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China.
| | - Ruili Wu
- Key Lab for Special Functional Materials of the Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China.
| | - Lin Song Li
- Key Lab for Special Functional Materials of the Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China.
| |
Collapse
|
15
|
Advantages of aggregation-induced luminescence microspheres compared with fluorescent microspheres in immunochromatography assay with sandwich format. Anal Chim Acta 2023; 1247:340869. [PMID: 36781245 DOI: 10.1016/j.aca.2023.340869] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Accepted: 01/20/2023] [Indexed: 01/22/2023]
Abstract
Organic fluorescein dye-embedded fluorescent microspheres (FMs) are currently the most established commercially fluorescent markers, and they have been widely used to improve the sensitivity of immunochromatography assay (ICA). However, these FMs have natural defects, such as the aggregation-caused quenching effect and small Stokes shift, which are not conducive to improving the detection performance of ICA. Herein, two green emitted FMs, namely aggregation-induced emission FMs (AIEFMs) and fluorescein isothiocyanate FMs (FITCFMs), were prepared by swelling the AIE luminogens and FITC dyes into the carboxyl group-modified polystyrene microspheres. The average diameters of AIEFMs and FITCFMs were 350 and 450 nm, respectively. Compared with FITCFMs, the AIEFMs exhibited stronger fluorescence intensity and a larger Stokes shift. These two FMs were used as the labeling markers of ICA for procalcitonin (PCT) detection with the sandwich format. Among them, AIEFM-ICA showed dynamic linear detection of PCT from 7.6 pg mL-1 to 125 ng mL-1 with the limit of detection (LOD) at 3.8 pg mL-1. These values were remarkably superior to those of FITCFM-ICA (linear range from 61 pg mL-1 to 62.5 ng mL-1 and LOD value at 60 pg mL-1). Furthermore, the average recoveries of the intra- and inter-assays of AIEFM-ICA ranged from 86% to 112%, with coefficients of variation ranging from 1.2% to 8.8%, indicating accuracy and precision for PCT quantitative detection. Additionally, the reliability of the developed AIEFM-ICA was further assessed by analyzing 30 real serum samples from systemic inflammatory response by infectious diseases, and the results showed good agreement with the chemiluminescence immunoassay. In conclusion, compared with traditional FITCFMs, green emitted AIEFMs as a novel fluorescent label, exhibits greater potential to enhance the detection performance of the ICA platform.
Collapse
|
16
|
Gumus E, Bingol H, Zor E. Lateral flow assays for detection of disease biomarkers. J Pharm Biomed Anal 2023; 225:115206. [PMID: 36586382 DOI: 10.1016/j.jpba.2022.115206] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/06/2022] [Accepted: 12/16/2022] [Indexed: 12/24/2022]
Abstract
Early diagnosis saves lives in many diseases. In this sense, monitoring of biomarkers is crucial for the diagnosis of diseases. Lateral flow assays (LFAs) have attracted great attention among paper-based point-of-care testing (POCT) due to their low cost, user-friendliness, and time-saving advantages. Developments in the field of health have led to an increase of interest in these rapid tests. LFAs are used in the diagnosis and monitoring of many diseases, thanks to biomarkers that can be observed in body fluids. This review covers the recent advances dealing with the design and strategies for the development of LFA for the detection of biomarkers used in clinical applications in the last 5 years. We focus on various strategies such as choosing the nanoparticle type, single or multiple test approaches, and equipment for signal transducing for the detection of the most common biomarkers in different diseases such as cancer, cardiovascular, infectious, and others including Parkinson's and Alzheimer's diseases. We expect that this study will contribute to the different approaches in LFA and pave the way for other clinical applications.
Collapse
Affiliation(s)
- Eda Gumus
- Biomaterials and Biotechnology Laboratory, Science and Technology Research and Application Center (BITAM), Necmettin Erbakan University, 42140 Konya, Turkey
| | - Haluk Bingol
- Biomaterials and Biotechnology Laboratory, Science and Technology Research and Application Center (BITAM), Necmettin Erbakan University, 42140 Konya, Turkey; Department of Chemistry Education, A.K. Education Faculty, Necmettin Erbakan University, 42090 Konya, Turkey
| | - Erhan Zor
- Biomaterials and Biotechnology Laboratory, Science and Technology Research and Application Center (BITAM), Necmettin Erbakan University, 42140 Konya, Turkey; Department of Science Education, A.K. Education Faculty, Necmettin Erbakan University, 42090 Konya, Turkey.
| |
Collapse
|
17
|
Recent progress on lateral flow immunoassays in foodborne pathogen detection. FOOD BIOSCI 2023. [DOI: 10.1016/j.fbio.2023.102475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
|
18
|
Silva-Neto HA, Arantes IV, Ferreira AL, do Nascimento GH, Meloni GN, de Araujo WR, Paixão TR, Coltro WK. Recent advances on paper-based microfluidic devices for bioanalysis. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116893] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
19
|
Ju J, Zhang X, Li L, Regmi S, Yang G, Tang S. Development of fluorescent lateral flow immunoassay for SARS-CoV-2-specific IgM and IgG based on aggregation-induced emission carbon dots. Front Bioeng Biotechnol 2022; 10:1042926. [PMID: 36312540 PMCID: PMC9608551 DOI: 10.3389/fbioe.2022.1042926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 09/28/2022] [Indexed: 11/13/2022] Open
Abstract
Understanding the dynamic changes in antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is essential for evaluating the effectiveness of the vaccine and the stage for the recovery of the COVID-19 disease. A rapid and accurate method for the detection of SARS-CoV-2-specific antibodies is still urgently needed. Here, we developed a novel fluorescent lateral flow immunoassay (LFA) platform for the detection of SARS-CoV-2-specific IgM and IgG by the aggregation-induced emission carbon dots conjugated with the SARS-CoV-2 spike protein (SSP). The aggregation-induced emission carbon dots (AIE-CDs) are one of the best prospect fluorescent probe materials for exhibiting high emission efficiency in both aggregate and solid states. The AIE-CDs were synthesized and displayed dual fluorescence emission, which provides a new perspective for the design of a high sensitivity testing system. In this work, the novel LFA platform adopted the AIE carbon dots, which are used to detect SARS-CoV-2-specific IgM and IgG conveniently. Furthermore, this sensor had a low LOD of 100 pg/ml. Therefore, this newly developed strategy has potential applications in the areas of public health for the advancement of clinical research.
Collapse
Affiliation(s)
- Jian Ju
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, China
- Oujiang Lab, Wenzhou, China
- *Correspondence: Jian Ju, ; Guoqiang Yang, ; Shixing Tang,
| | - Xinyu Zhang
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, China
| | - Lin Li
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, China
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
| | - Sagar Regmi
- Department of Pharmacology, School of Medicine, Case Western Reserve University, Cleveland, OH, United States
| | - Guoqiang Yang
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, China
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- Key Laboratory of Photochemistry, Institute of Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, Beijing, China
- *Correspondence: Jian Ju, ; Guoqiang Yang, ; Shixing Tang,
| | - Shixing Tang
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, China
- Department of Epidemiology, School of Public Health, Southern Medical University, Guangzhou, China
- *Correspondence: Jian Ju, ; Guoqiang Yang, ; Shixing Tang,
| |
Collapse
|
20
|
Sensitive and simultaneous detection of ractopamine and salbutamol using multiplex lateral flow immunoassay based on polyethyleneimine-mediated SiO2@QDs nanocomposites: Comparison and application. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
21
|
Wang XM, Li S, Li LH, Song JX, Lu YH, Zhou ZW, Zhang L. Triple quantitative detection of three inflammatory biomarkers with a biotin-streptavidin-phycoerythrin based lateral flow immunoassay. Anal Biochem 2022; 657:114915. [PMID: 36162446 DOI: 10.1016/j.ab.2022.114915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 08/25/2022] [Accepted: 09/14/2022] [Indexed: 11/16/2022]
Abstract
Quantified inflammatory biomarkers are effective clinical strategy for correct and reasonable drug treatment. In the study, a triple lateral flow immunoassay (triple LFIA) had firstly been developed for specific and simultaneous detection of three pivotal inflammatory biomarkers (PCT, CRP and SAA) via biotin-streptavidin-phycoerythrin signal amplification system in one strip. The developed triple LFIA adopted phycoerythrin (PE) as chromophore to eliminate auto-fluorescence interference from plasma biomolecules and anti-PE mAb as single control line to reduce the nonspecific adsorption, which featured particular advantages in high sensitivity and specificity in a large range of analyte concentrations with the LODs of 0.106 ng/mL for PCT, 0.345 μg/mL for CRP and 3.112 μg/mL SAA, respectively. And the linear quantitative detection ranges were from 0.106 to 100 ng/mL, from 0.345 to 200 μg/mL, and from 3.112 to 200 μg/mL, respectively. Compared to commercial chemiluminescence immunoassay method, the correlations for tested PCT, CRP and SAA in 108 clinical samples were 0.989, 0.987 and 0.988, respectively. In summary, we had proposed a rapid and accurate plasma detection to measure inflammation factors, which facilitated the clinical value to achieve precise treatment.
Collapse
Affiliation(s)
- Xiao-Ming Wang
- School of Biology and Biological Engineering, South China University of Technology, Guangzhou, 510006, PR China
| | - Shan Li
- School of Biology and Biological Engineering, South China University of Technology, Guangzhou, 510006, PR China
| | - Lin-Hai Li
- Department of Laboratory Medicine, General Hospital of Southern Theatre Command of PLA, Guangzhou, 510010, PR China
| | - Jian-Xun Song
- Guangzhou Tebsun Bio-Tech Development Co., Ltd., Guangzhou, 510663, PR China
| | - Yan-Hua Lu
- Guangzhou Tebsun Bio-Tech Development Co., Ltd., Guangzhou, 510663, PR China
| | - Zhi-Wei Zhou
- Guangzhou Tebsun Bio-Tech Development Co., Ltd., Guangzhou, 510663, PR China
| | - Lei Zhang
- School of Biology and Biological Engineering, South China University of Technology, Guangzhou, 510006, PR China.
| |
Collapse
|
22
|
|
23
|
Boegner DJ, Everitt ML, White IM. Thermally Responsive Alkane Partitions for Assay Automation. ACS APPLIED MATERIALS & INTERFACES 2022; 14:8865-8875. [PMID: 35147027 PMCID: PMC10044609 DOI: 10.1021/acsami.2c00493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
For point-of-care diagnostic tools to be impactful, they must be inexpensive, equipment-free, and sample-to-answer (i.e., require no user intervention). Here, we report a new approach to enable sample-to-answer diagnostics that utilizes thermally responsive alkane partitions (TRAPs) as automated pseudo-valves. When combined with the magnetic manipulation of microbeads, TRAPs enable the pumpless automation of all steps in complex assays. We demonstrate that in relatively narrow channel geometries, liquified alkane partitions continue to separate reagents on each side of the partition while enabling the transition of magnetic beads from one reagent to the next, replacing manual pipetting steps in conventional assays. In addition, we show that in relatively broader geometries, liquified partitions breach, enabling the addition/mixing of preloaded reagents. Through calculation and experimentation, we determine the geometric design rules for implementing the stationary and removable partitions in fluidic channels. In addition, we demonstrate that magnetic microbeads can be pulled through liquified stationary TRAPs without disrupting partition integrity and without disrupting bound protein complexes attached at the microbead surface. The TRAP technology introduced here can enable a new low-cost and equipment-free approach for fully automated sample-to-answer diagnostics.
Collapse
Affiliation(s)
- David J Boegner
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, Maryland 20742, United States
| | - Micaela L Everitt
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, Maryland 20742, United States
| | - Ian M White
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, Maryland 20742, United States
| |
Collapse
|
24
|
Bai F, Bu T, Li R, Zhao S, He K, Li M, Zhang H, Zhang Y, Zhang L, Wang Y, Wang L. Rose petals-like Bi semimetal embedded on the zeolitic imidazolate frameworks based-immunochromatographic strip to sensitively detect acetamiprid. JOURNAL OF HAZARDOUS MATERIALS 2022; 423:127202. [PMID: 34536846 DOI: 10.1016/j.jhazmat.2021.127202] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Revised: 08/27/2021] [Accepted: 09/08/2021] [Indexed: 06/13/2023]
Abstract
Ultrasensitive and facile detection of Acetamiprid (ACE) is of exceptional significance to assess the environmental and biological pollution. In this study, an advanced Bi semimetal/Zeolitic imidazolate frameworks hybrid material-based immunochromatographic strip (Bi/ZIF HM-ICS) sensor was developed for the sensitive detection of ACE. The novel Bi/ZIF HM was prepared through one-pot hydrothermal reduction of Bi nanoparticles on ZIF, which was selected as a signal tag taking advantages of its excellent color intensity, strong affinity with monoclonal antibodies (mAbs), and favorable biocompatibility. Bi/ZIF HM could not only improve the utilization efficiency of mAbs but also boost the sensing performance. Under optimal conditions, the limit of detection (LOD) of the Bi/ZIF HM-ICS was 4.68 pg/mL with the linear range from 0.01 ng/mL to 6 ng/mL, which was 98-fold lower than that of traditional gold nanoparticles-based ICS (0.457 ng/mL), and the recoveries of the Bi/ZIF HM-ICS ranged from 80.27% to 118.52% with the relative standard deviation (RSD) below 3.67% in pear, apple, tomato, and cucumber. Overall, the practical application of the Bi/ZIF HM-ICS in complicated samples was realized for detecting pesticide residue, and expanding its application scope in monitoring environment.
Collapse
Affiliation(s)
- Feier Bai
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Tong Bu
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Ruixia Li
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Shuang Zhao
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Kunyi He
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Mingyan Li
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Hui Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Yalan Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Lin Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Ying Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Li Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.
| |
Collapse
|
25
|
A diagnostic platform for rapid, simultaneous quantification of procalcitonin and C-reactive protein in human serum. EBioMedicine 2022; 76:103867. [PMID: 35149284 PMCID: PMC8841998 DOI: 10.1016/j.ebiom.2022.103867] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Revised: 01/12/2022] [Accepted: 01/19/2022] [Indexed: 01/08/2023] Open
Abstract
Background Early and accurate determination of bacterial infections as a potential cause for a patient's systemic inflammatory response is required for timely administration of appropriate treatment and antibiotic stewardship. Procalcitonin (PCT) and C-reactive protein (CRP) have both been used as biomarkers to infer bacterial infections, particularly in the context of sepsis. There is an urgent need to develop a platform for simultaneous quantification of PCT and CRP, to enable the potential use of these biomarkers at the point-of-care. Methods A multiplexed lateral flow assay (LFA) and a fluorescence optical reader were developed. Assay performance was validated by testing spiked antigens in the buffer, followed by a validation study comparing results with conventional assays (Roche Cobas e411 Elecsys PCT and Siemens ADVIA XPT CRP) in 25 archived remnant human serum samples. Findings A linear regression correlation of 0·97 (P < 0·01) was observed for PCT, and a correlation of 0·95 (P < 0·01) was observed for CRP using direct patient samples. We also validated our platform's ability to accurately quantify high-dose CRP in the hook effect range where excess unlabeled analytes occupy binding sites at test lines. Interpretation A fluorescence reader-based duplex LFA for simultaneous quantification of PCT and CRP was developed and successfully validated with clinical samples. The rapid, portable, and low-cost nature of the platform offers potential for differentiation of bacterial and viral infections in emergency and low-resource settings at the point-of-care. Funding NIH/NIBIB Award 1R01EB021331, and Academic Venture Fund from the Atkinson Center for a Sustainable Future at Cornell University.
Collapse
|
26
|
Han H, Wang C, Yang X, Zheng S, Cheng X, Liu Z, Zhao B, Xiao R. Rapid field determination of SARS-CoV-2 by a colorimetric and fluorescent dual-functional lateral flow immunoassay biosensor. SENSORS AND ACTUATORS. B, CHEMICAL 2022; 351:130897. [PMID: 34658530 PMCID: PMC8500848 DOI: 10.1016/j.snb.2021.130897] [Citation(s) in RCA: 52] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2021] [Revised: 09/12/2021] [Accepted: 10/07/2021] [Indexed: 05/06/2023]
Abstract
The rapid and accurate diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) at the early stage of virus infection can effectively prevent the spread of the virus and control the epidemic. Here, a colorimetric and fluorescent dual-functional lateral flow immunoassay (LFIA) biosensor was developed for the rapid and sensitive detection of spike 1 (S1) protein of SARS-CoV-2. A novel dual-functional immune label was fabricated by coating a single-layer shell formed by mixing 20 nm Au nanoparticles (Au NPs) and quantum dots (QDs) on SiO2 core to produce strong colorimetric and fluorescence signals and ensure good monodispersity and high stability. The colorimetric signal was used for visual detection and rapid screening of suspected SARS-CoV-2 infection on sites. The fluorescence signal was utilized for sensitive and quantitative detection of virus infection at the early stage. The detection limits of detecting S1 protein via colorimetric and fluorescence functions of the biosensor were 1 and 0.033 ng/mL, respectively. Furthermore, we evaluated the performance of the biosensor for analyzing real samples. The novel biosensor developed herein had good repeatability, specificity and accuracy, which showed great potential as a tool for rapidly detecting SARS-CoV-2.
Collapse
Affiliation(s)
- Han Han
- College of Life Science, Hebei Normal University, Shijiazhuang 050024, PR China
- Beijing Institute of Radiation Medicine, Beijing 100850, PR China
| | - Chongwen Wang
- Beijing Institute of Radiation Medicine, Beijing 100850, PR China
- College of Life Sciences, Anhui Agricultural University, Hefei 230036, PR China
| | - Xingsheng Yang
- Beijing Institute of Radiation Medicine, Beijing 100850, PR China
| | - Shuai Zheng
- Beijing Institute of Radiation Medicine, Beijing 100850, PR China
- College of Life Sciences, Anhui Agricultural University, Hefei 230036, PR China
| | - Xiaodan Cheng
- Beijing Institute of Radiation Medicine, Beijing 100850, PR China
- College of Life Sciences, Anhui Agricultural University, Hefei 230036, PR China
| | - Zhenzhen Liu
- Beijing Institute of Radiation Medicine, Beijing 100850, PR China
| | - Baohua Zhao
- College of Life Science, Hebei Normal University, Shijiazhuang 050024, PR China
| | - Rui Xiao
- Beijing Institute of Radiation Medicine, Beijing 100850, PR China
| |
Collapse
|
27
|
Hang Y, Boryczka J, Wu N. Visible-light and near-infrared fluorescence and surface-enhanced Raman scattering point-of-care sensing and bio-imaging: a review. Chem Soc Rev 2022; 51:329-375. [PMID: 34897302 PMCID: PMC9135580 DOI: 10.1039/c9cs00621d] [Citation(s) in RCA: 99] [Impact Index Per Article: 33.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
This review article deals with the concepts, principles and applications of visible-light and near-infrared (NIR) fluorescence and surface-enhanced Raman scattering (SERS) in in vitro point-of-care testing (POCT) and in vivo bio-imaging. It has discussed how to utilize the biological transparency windows to improve the penetration depth and signal-to-noise ratio, and how to use surface plasmon resonance (SPR) to amplify fluorescence and SERS signals. This article has highlighted some plasmonic fluorescence and SERS probes. It has also reviewed the design strategies of fluorescent and SERS sensors in the detection of metal ions, small molecules, proteins and nucleic acids. Particularly, it has provided perspectives on the integration of fluorescent and SERS sensors into microfluidic chips as lab-on-chips to realize point-of-care testing. It has also discussed the design of active microfluidic devices and non-paper- or paper-based lateral flow assays for in vitro diagnostics. In addition, this article has discussed the strategies to design in vivo NIR fluorescence and SERS bio-imaging platforms for monitoring physiological processes and disease progression in live cells and tissues. Moreover, it has highlighted the applications of POCT and bio-imaging in testing toxins, heavy metals, illicit drugs, cancers, traumatic brain injuries, and infectious diseases such as COVID-19, influenza, HIV and sepsis.
Collapse
Affiliation(s)
- Yingjie Hang
- Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, MA 01003-9303, USA.
| | - Jennifer Boryczka
- Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, MA 01003-9303, USA.
| | - Nianqiang Wu
- Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, MA 01003-9303, USA.
| |
Collapse
|
28
|
Wang Z, Zhao J, Xu X, Guo L, Xu L, Sun M, Hu S, Kuang H, Xu C, Li A. An Overview for the Nanoparticles-Based Quantitative Lateral Flow Assay. SMALL METHODS 2022; 6:e2101143. [PMID: 35041285 DOI: 10.1002/smtd.202101143] [Citation(s) in RCA: 42] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 10/27/2021] [Indexed: 06/14/2023]
Abstract
The development of the lateral flow assay (LFA) has received much attention in both academia and industry because of their broad applications to food safety, environmental monitoring, clinical diagnosis, and so forth. The user friendliness, low cost, and easy operation are the most attractive advantages of the LFA. In recent years, quantitative detection has become another focus of LFA development. Here, the most recent studies of quantitative LFAs are reviewed. First, the principles and corresponding formats of quantitative LFAs are introduced. In the biomaterial and nanomaterial sections, the detection, capture, and signal amplification biomolecules and the optical, fluorescent, luminescent, and magnetic labels used in LFAs are described. The invention of dedicated strip readers has drawn further interest in exploiting the better performance of LFAs. Therefore, next, the development of dedicated reader devices is described and the usefulness and specifications of these devices for LFAs are discussed. Finally, the applications of LFAs in the detection of metal ions, biotoxins, pathogenic microorganisms, veterinary drugs, and pesticides in the fields of food safety and environmental health and the detection of nucleic acids, biomarkers, and viruses in clinical analyses are summarized.
Collapse
Affiliation(s)
- Zhongxing Wang
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Jing Zhao
- Department of Radiology, Affiliated Hospital, Jiangnan University, No. 1000, Hefeng Road, Wuxi, Jiangsu, 214122, China
| | - Xinxin Xu
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Lingling Guo
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Liguang Xu
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Maozhong Sun
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Shudong Hu
- Department of Radiology, Affiliated Hospital, Jiangnan University, No. 1000, Hefeng Road, Wuxi, Jiangsu, 214122, China
| | - Hua Kuang
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Chuanlai Xu
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Aike Li
- Academy of National Food and Strategic Reserves Administration, No. 11, Baiwanzhuang Street, Beijing, 100037, P. R. China
| |
Collapse
|
29
|
Gao F, Liu C, Yao Y, Lei C, Li S, Yuan L, Song H, Yang Y, Wan J, Yu C. Quantum dots' size matters for balancing their quantity and quality in label materials to improve lateral flow immunoassay performance for C-reactive protein determination. Biosens Bioelectron 2021; 199:113892. [PMID: 34933225 DOI: 10.1016/j.bios.2021.113892] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 12/12/2021] [Accepted: 12/13/2021] [Indexed: 12/18/2022]
Abstract
Incorporating quantum dots (QDs) into dendritic mesoporous silica nanoparticles (DMSNs) for signal amplification of label materials represents an efficient strategy to improve the performance of lateral flow immunoassays (LFIAs). In this work, it is found that the CdSe/ZnS QD's size matters for balancing their loading amount and quantum yields (QYs) in the DMSNs-QDs based label materials and ultimately determining the performance of LFIA. The impacts of three CdSe/ZnS QDs with diameters of 9.1, 10.5 and 11.7 nm on CdSe/ZnS QDs incorporation and LFIA applications are studied. The increase of CdSe/ZnS QDs size from 9.1 to 11.7 nm results in a decrease in CdSe/ZnS QDs loading amount and an increase in QYs of incorporated CdSe/ZnS QDs. This trade-off leads to an optimized CdSe/ZnS QDs size of 10.5 nm, which exhibits the best LFIA performance due to the balanced QDs loading (2.26 g g-1) and QY (57.1%). The 10.5 nm CdSe/ZnS QDs incorporated DMSNs-QDs for C-reactive protein (CRP) detection achieved a limit of detection of 5 pg mL-1 (equivalent to 4.2 × 10-14 M) with naked eye, which is lower than literature reports and commercial LFIA products. This study demonstrates that the CdSe/ZnS QD's size matters for improving the quality of DMSNs-QDs and their LFIA performance for CRP determination, providing new insights into the rational design of advanced label materials for improving LFIA performance.
Collapse
Affiliation(s)
- Fang Gao
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, Queensland, 4072, Australia
| | - Chao Liu
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, 200241, PR China
| | - Yining Yao
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, 200241, PR China
| | - Chang Lei
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, Queensland, 4072, Australia.
| | - Shumin Li
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, 200241, PR China
| | - Ling Yuan
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, 200241, PR China
| | - Hao Song
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, Queensland, 4072, Australia
| | - Yannan Yang
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, Queensland, 4072, Australia
| | - Jingjing Wan
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, 200241, PR China
| | - Chengzhong Yu
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, Queensland, 4072, Australia; School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, 200241, PR China.
| |
Collapse
|
30
|
Castro RC, Saraiva MLM, Santos JL, Ribeiro DS. Multiplexed detection using quantum dots as photoluminescent sensing elements or optical labels. Coord Chem Rev 2021. [DOI: 10.1016/j.ccr.2021.214181] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
31
|
Fluorescent paper strip immunoassay with carbon nanodots@silica for determination of human serum amyloid A1. Mikrochim Acta 2021; 188:386. [PMID: 34664145 DOI: 10.1007/s00604-021-05019-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Accepted: 09/05/2021] [Indexed: 10/20/2022]
Abstract
A fluorescent paper strip immunoassay in conjunction with carbon nanodots@silica (CND@SiO2) as a label was developed for the quantitative measurements of human serum amyloid A1 (hSAA1) in serum at clinically significant concentrations for lung cancer diagnosis. Monodispersed CND@SiO2 was prepared by cohydrolysis between silane-crosslinked carbon nanodots and silica precursors via the Ströber method and further attached covalently to anti-hSAA1 (14F8) monoclonal antibody [anti-hSAA1(14F8)] specific to the hSAA1 target. The hSAA1 concentrations were then determined by quantifying the blue fluorescence intensity upon 365 nm excitation of the captured hSAA1 with anti-hSAA1(14F8)-CND@SiO2 conjugates in the test line on a paper strip where anti-hSAA1 (10G1) monoclonal antibody was physisorbed. The developed fluorescent paper strip with CND@SiO2 can detect hSAA1 at concentrations ranging from 0.1 to 5 nM (R2 = 0.995), with a limit of detection of 0.258 nM in 10 mM phosphate buffer pH 7.4 containing human serum albumin. The performance of recovery (90.98-109.17%) and repeatability (coefficients of variation < 8.46%) obtained was also acceptable for quantitative determinations. The platform was employed for direct determination of hSAA1 concentrations in undiluted serum samples from lung cancer patients (relative standard deviation (RSD) < 7.46%) and healthy humans (RSD < 3.96%). The results were compared with those obtained using a commercially available enzyme-linked immunosorbent assay alongside liquid chromatography with tandem mass spectrometry measurements.
Collapse
|
32
|
Wang C, Yang X, Zheng S, Cheng X, Xiao R, Li Q, Wang W, Liu X, Wang S. Development of an ultrasensitive fluorescent immunochromatographic assay based on multilayer quantum dot nanobead for simultaneous detection of SARS-CoV-2 antigen and influenza A virus. SENSORS AND ACTUATORS. B, CHEMICAL 2021; 345:130372. [PMID: 34219970 PMCID: PMC8239248 DOI: 10.1016/j.snb.2021.130372] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2021] [Revised: 06/15/2021] [Accepted: 06/26/2021] [Indexed: 05/02/2023]
Abstract
Rapid and accurate diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza A virus (FluA) antigens in the early stages of virus infection is the key to control the epidemic spread. Here, we developed a two-channel fluorescent immunochromatographic assay (ICA) for ultrasensitive and simultaneous qualification of the two viruses in biological samples. A high-performance quantum dot nanobead (QB) was fabricated by adsorption of multilayers of dense quantum dots (QDs) onto the SiO2 surface and used as the highly luminescent label of the ICA system to ensure the high-sensitivity and stability of the assay. The combination of monodispersed SiO2 core (∼180 nm) and numerous carboxylated QDs formed a hierarchical shell, which ensured that the QBs possessed excellent stability, superior fluorescence signal, and convenient surface functionalization. The developed ICA biosensor achieved simultaneous detection of SARS-CoV-2 and FluA in one test within 15 min, with detection limits reaching 5 pg/mL for SARS-CoV-2 antigen and 50 pfu/mL for FluA H1N1. Moreover, our method showed high accuracy and specificity in throat swab samples with two orders of magnitude improvement in sensitivity compared with traditional AuNP-based ICA method. Hence, the proposed method is a promising and convenient tool for detection of respiratory viruses.
Collapse
Affiliation(s)
- Chongwen Wang
- College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Xingsheng Yang
- College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Shuai Zheng
- College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Xiaodan Cheng
- College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Rui Xiao
- College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Qingjun Li
- School of Pharmacy, Shandong University of Traditional Chinese Medicine, Jinan, 250355, PR China
| | - Wenqi Wang
- College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Xiaoxian Liu
- College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Shengqi Wang
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| |
Collapse
|
33
|
Li Y, Liu X, Guo J, Zhang Y, Guo J, Wu X, Wang B, Ma X. Simultaneous Detection of Inflammatory Biomarkers by SERS Nanotag-Based Lateral Flow Assay with Portable Cloud Raman Spectrometer. NANOMATERIALS (BASEL, SWITZERLAND) 2021; 11:1496. [PMID: 34198765 PMCID: PMC8226521 DOI: 10.3390/nano11061496] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Revised: 05/29/2021] [Accepted: 05/31/2021] [Indexed: 01/22/2023]
Abstract
Inflammatory biomarkers are closely related to infectious diseases. However, traditional clinical tests of laboratory inspection are unable to achieve rapid and accurate detection of these biomarkers on-site due to shortcomings such as complex experimental operation, expensive equipment, and long test time. Herein, we proposed a lateral flow assay (LFA) strip based on surface-enhanced Raman scattering (SERS) nanotags (SERS-LFA strips) for the simultaneous and quantitative detection of dual infection biomarkers, serum amyloid A (SAA) and C-reactive protein (CRP), respectively. In practice, mesoporous silica (mSiO2)-coated Au nanoparticles (Au NPs) were used as the SERS substrate. Mercaptobenzoic acid (MBA) was embedded in the internal gap between Au NPs and the mSiO2 shell to prepare AuMBA@mSiO2 NPs, onto which SAA and CRP antibodies were modified to prepare two AuMBA@mSiO2 SERS nanotags. The Raman intensities of the test and control lines were simultaneously identified for the qualitative detection of SAA and CRP, with limits of detection (LODs) as low as 0.1 and 0.05 ng/mL for SAA and CRP, respectively. Finally, aiming at point-of-care testing (POCT) applications, we used a smartphone-based portable Raman spectrometer to quantitatively analyze the SERS-LFA strips. The Raman signal could still be accurately detected when the concentration of SAA and CRP was 10 ng/mL, which is lower than the LOD required in clinical practice for most diseases. Therefore, taking into account its simple operation and short analysis time, by using a portable Raman spectrometer which can be equipped with a 5G cloud-based healthcare management system, the current strategy based on SERS-LFA provides the potential for the quick and on-site diagnosis of infectious diseases such as sepsis, which is of great significance for medical guidance on the treatment of widely spread infection-related diseases in remote areas that lack well-developed medical resources.
Collapse
Affiliation(s)
- Yang Li
- School of Materials Engineering, Shanghai University of Engineering Science, Shanghai 201620, China; (Y.L.); (Y.Z.)
| | - Xiaojia Liu
- Sauvage Laboratory for Smart Materials, School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China;
- Shenzhen Bay Laboratory, No. 9 Duxue Road, Shenzhen 518055, China
| | - Jiuchuan Guo
- School of Communication and Information Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China; (J.G.); (J.G.)
| | - Yueting Zhang
- School of Materials Engineering, Shanghai University of Engineering Science, Shanghai 201620, China; (Y.L.); (Y.Z.)
| | - Jinhong Guo
- School of Communication and Information Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China; (J.G.); (J.G.)
| | - Xinggui Wu
- CloudMinds Inc., Shenzhen Bay Science and Technology Ecological Park, Shenzhen 100022, China
| | - Bo Wang
- School of Materials Engineering, Shanghai University of Engineering Science, Shanghai 201620, China; (Y.L.); (Y.Z.)
| | - Xing Ma
- Sauvage Laboratory for Smart Materials, School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China;
- Shenzhen Bay Laboratory, No. 9 Duxue Road, Shenzhen 518055, China
| |
Collapse
|
34
|
Liu X, Ren X, Chen L, Zou J, Li T, Tan L, Fu C, Wu Q, Li C, Wang J, Huang Z, Meng X. Fluorescent hollow ZrO 2@CdTe nanoparticles-based lateral flow assay for simultaneous detection of C-reactive protein and troponin T. Mikrochim Acta 2021; 188:209. [PMID: 34047819 DOI: 10.1007/s00604-021-04865-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2020] [Accepted: 05/13/2021] [Indexed: 01/07/2023]
Abstract
Highly fluorescent hollow ZrO2@CdTe nanoparticles (NPs) were synthesized efficiently via the hydrothermal method. By changing the hydrothermal time of ZrO2@CdTe NP, the peaks of fluorescence spectra measured at fluorescent excitation of 330 nm were at 540 nm, 590 nm, and 640 nm, respectively. Hollow ZrO2 NPs have a uniform core-shell structure with the size of 178 ± 10 nm and shell of 19 ± 4 nm. The as-prepared yellow-ZrO2@CdTe NPs were used to develop lateral flow assay (LFA) for the sensitive and qualitative detection of C-reactive protein (CRP). The visual limit of detection of the LFA for the CRP antigen was 1 μg/L within 20 min, which is 1000-fold lower than that of colloidal gold-based LFA. In addition, a multiplex lateral flow assay (mLFA) was developed using the as-prepared green and red-ZrO2@CdTe NPs for the simultaneous, specific, sensitive, and qualitative detection of CRP and troponin T (cTnT). The visual limits of detection of CRP and cTnT in mLFA were 10 μg/L and 0.1 mg/L, respectively. The excellent performance of ZrO2@CdTe NPs should facilitate their application in point-of-care technology for the detection of other biomarkers.
Collapse
Affiliation(s)
- Xin Liu
- Laboratory of Controllable Preparation and Application of Nanomaterials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
- College of Materials Science & Engineering, Sichuan University, Chengdu, 610065, China
- CAS Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
| | - Xiangling Ren
- Laboratory of Controllable Preparation and Application of Nanomaterials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
- CAS Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Lufeng Chen
- First Clinical Medical School and First Hospital, Shanxi Medical University, 030001, Taiyuan, China
| | - Jian Zou
- Laboratory of Controllable Preparation and Application of Nanomaterials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
- College of Materials Science & Engineering, Sichuan University, Chengdu, 610065, China
- CAS Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
| | - Ting Li
- Laboratory of Controllable Preparation and Application of Nanomaterials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
- CAS Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Longfei Tan
- Laboratory of Controllable Preparation and Application of Nanomaterials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
- CAS Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
| | - Changhui Fu
- Laboratory of Controllable Preparation and Application of Nanomaterials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
- CAS Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
| | - Qiong Wu
- Laboratory of Controllable Preparation and Application of Nanomaterials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
- CAS Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
| | - Chaohui Li
- Beijing Zhongsheng Jinyu Diagnostic Technology Corporation Co. Ltd, Beijing, 102200, China
| | - Jiayi Wang
- Beijing Zhongsheng Jinyu Diagnostic Technology Corporation Co. Ltd, Beijing, 102200, China
| | - Zhongbing Huang
- College of Materials Science & Engineering, Sichuan University, Chengdu, 610065, China
| | - Xianwei Meng
- Laboratory of Controllable Preparation and Application of Nanomaterials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China.
- CAS Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China.
| |
Collapse
|
35
|
Wang S, Shen W, Zheng S, Li Z, Wang C, Zhang L, Liu Y. Dual-signal lateral flow assay using vancomycin-modified nanotags for rapid and sensitive detection of Staphylococcus aureus. RSC Adv 2021; 11:13297-13303. [PMID: 35423879 PMCID: PMC8697553 DOI: 10.1039/d1ra01085a] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Accepted: 03/28/2021] [Indexed: 12/17/2022] Open
Abstract
This paper reports a colorimetric-fluorescent dual-signal lateral flow assay (LFA) based on vancomycin (Van)-modified SiO2-Au-QD tags for sensitive and quantitative detection of Staphylococcus aureus (S. aureus). The combination of high-performance Van-tags and detection antibodies integrated into the LFA system produced assays with high sensitivity and specificity. The visualization limit of the colorimetric signal and the detection limit of the fluorescence signal of the proposed method for S. aureus can reach 104 and 100 cells mL-1, respectively.
Collapse
Affiliation(s)
- Shu Wang
- Hefei Institute of Physical Science, Chinese Academy of Sciences Hefei 230036 PR China
- University of Science and Technology of China Hefei 230036 PR China
| | - Wanzhu Shen
- Anhui Agricultural University Hefei 230036 PR China
- Beijing Institute of Radiation Medicine Beijing 100850 PR China
| | - Shuai Zheng
- Anhui Agricultural University Hefei 230036 PR China
- Beijing Institute of Radiation Medicine Beijing 100850 PR China
| | - Zhigang Li
- Hefei Institute of Physical Science, Chinese Academy of Sciences Hefei 230036 PR China
| | - Chongwen Wang
- Anhui Agricultural University Hefei 230036 PR China
- Beijing Institute of Radiation Medicine Beijing 100850 PR China
| | - Long Zhang
- Hefei Institute of Physical Science, Chinese Academy of Sciences Hefei 230036 PR China
- University of Science and Technology of China Hefei 230036 PR China
| | - Yong Liu
- Hefei Institute of Physical Science, Chinese Academy of Sciences Hefei 230036 PR China
- University of Science and Technology of China Hefei 230036 PR China
| |
Collapse
|