1
|
Deng H, Liu F, He J. The Effect of Inorganic Filler Content on the Properties of BPA-Free Bulk-Fill Dental Resin Composites. MATERIALS (BASEL, SWITZERLAND) 2024; 17:5040. [PMID: 39459745 PMCID: PMC11509294 DOI: 10.3390/ma17205040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2024] [Revised: 10/10/2024] [Accepted: 10/14/2024] [Indexed: 10/28/2024]
Abstract
This study aimed to enhance the performance of dental resin composites (DRCs) by increasing the content of inorganic fillers while addressing potential health risks associated with Bisphenol A (BPA). To achieve this, the BPA-based resin monomer Bis-GMA was replaced with BPA-free Bis-EFMA. The study then explored the impact of varying inorganic filler contents on the physiochemical properties of Bis-EFMA-based bulk-fill dental resin composites (BF-DRCs). Four distinct Bis-EFMA-based BF-DRCs were formulated, each with different inorganic filler contents ranging from 70 wt% to 76 wt%. The study tested the depth of cure (DOC), double-bond conversion (DC), water sorption (WS), solubility (SL), and cytotoxicity of the system. It notably investigated the effects of increasing filler content on mechanical properties through flexural strength (FS), flexural modulus (FM), Vickers microhardness (VHN), and wear resistance, as well as the impact on polymerization shrinkage, including volumetric shrinkage (VS) and shrinkage stress (SS). To assess the commercial application potential of Bis-EFMA-based BF-DRC, the research used the commercially available BF-DRC Filtek Bulk-Fill Posterior (FBF) as a control. The results indicated that a higher filler content did not affect the DOC of Bis-EFMA-based BF-DRCs. Inorganic fillers at higher concentrations significantly enhanced overall mechanical properties while significantly reducing volumetric shrinkage (VS; p < 0.05). When the concentration of inorganic fillers in the resin system reached 76 wt%, most of the performance of the Bis-EFMA-based BF-DRC surpassed that of the commercial control FBF, except for FS, FM, and SS. These findings highlight the potential of Bis-EFMA-based BF-DRC as a long-term restorative material for dental applications.
Collapse
Affiliation(s)
| | | | - Jingwei He
- School of Materials Science and Engineering, South China University of Technology, Guangzhou 510641, China; (H.D.); (F.L.)
| |
Collapse
|
2
|
Alghazaly A, Mirah M, Saleh S. Immediate and delayed shear bond strength evaluation between root canal sealers and restorative materials: an experimental study. BMC Oral Health 2024; 24:1217. [PMID: 39402532 PMCID: PMC11475602 DOI: 10.1186/s12903-024-04993-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Accepted: 10/01/2024] [Indexed: 10/19/2024] Open
Abstract
BACKGROUND Several calcium silicate-based sealers have recently emerged in endodontics. This study aimed to compare the immediate and delayed shear bond strength between the bioceramic and calcium hydroxide-based sealers and different resin-based restorative materials. METHODS One hundred and twenty specimens with a 3-mm depth and a 3-mm diameter were prepared. They were evenly divided into two groups, the bioceramic sealer and calcium hydroxide-based sealer groups. Each primary group was subdivided into two subgroups based on the restorative material used; i.e., the flowable resin composite and resin-modified glass ionomer subgroups. Moreover, each subgroup was further divided into the restoration process's timing: either immediately post-sealing or delayed after setting the sealers for seven days. The mode of failure was assessed by stereomicroscopic examination. RESULTS The highest shear bond strength was found when the bioceramic sealer was used and restored with the flowable resin composite. The strengths were 8.45 (1.17) and 6.67 (1.60) megapascals (MPa) in the immediate and delayed restoration groups, respectively. In contrast, the lowest strength, 2.91 (1.22) MPa, was recorded when calcium hydroxide-based sealer was employed and restored after allowing the sealer to set completely with resin-modified glass ionomer. Notably, there were no cohesive fractures within the tested restorative materials. All observed fractures occurred within the sealer materials, at the interface of the sealer and restorative material, or in combination. Moreover, the most common failure was a mixed failure. CONCLUSIONS When flowable resin composite was used immediately before complete setting, bioceramic sealers showed a higher bond strength than calcium hydroxide-based sealers.
Collapse
Affiliation(s)
- Amira Alghazaly
- Department of Restorative Dental Science, College of Dentistry, Taibah University, Madinah, Saudi Arabia
| | - Mahir Mirah
- Department of Restorative Dental Science, College of Dentistry, Taibah University, Madinah, Saudi Arabia.
| | - Somaya Saleh
- Department of Restorative Dental Science, College of Dentistry, Taibah University, Madinah, Saudi Arabia
- Department of Operative Dentistry, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
- Operative Division, Department of Restorative Dental Science, College of Dentistry, Taibah University, Madinah, Saudi Arabia
| |
Collapse
|
3
|
Wysokińska-Miszczuk J, Piotrowska K, Paulo M, Madej M. Composite Materials Used for Dental Fillings. MATERIALS (BASEL, SWITZERLAND) 2024; 17:4936. [PMID: 39410505 PMCID: PMC11477701 DOI: 10.3390/ma17194936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2024] [Revised: 10/03/2024] [Accepted: 10/08/2024] [Indexed: 10/20/2024]
Abstract
This article explores the properties of composite materials employed in dental fillings. A traditional nano-hybrid composite containing nanofiller particles exceeding 82% by weight served as a benchmark. The remaining samples were fabricated from ormocer resin, maintaining an identical nanofiller content of 84%. In all specimens, the nanoparticles were dispersed randomly within the matrix. This study presents findings from investigations into surface geometry, hardness, wettability, and tribological behavior. The microscopic observations revealed that ormocer-based samples exhibited greater surface roughness than those composed of the traditional composite. Hardness testing indicated that both ceramic addition and sample preparation significantly influenced mechanical properties. Ceramic-enhanced samples demonstrated superior hardness, surpassing the reference composite by 30% and 43%, respectively. Contact angle measurements revealed hydrophilic characteristics in the classic composite, contrasting with the hydrophobic nature of ceramic-containing samples. Tribological evaluations revealed the superiority of the classic composite in terms of friction coefficients and volumetric wear compared to ormocer-based materials.
Collapse
Affiliation(s)
- Joanna Wysokińska-Miszczuk
- Faculty of Medical Dentistry, Medical University of Lublin, ul. Chodźki 6 Ave, 20-093 Lublin, Poland; (J.W.-M.); (M.P.)
| | - Katarzyna Piotrowska
- Faculty of Mechatronics and Mechanical Engineering, Kielce University of Technology, al. Tysiąclecia Państwa Polskiego 7, 25-314 Kielce, Poland;
| | - Michał Paulo
- Faculty of Medical Dentistry, Medical University of Lublin, ul. Chodźki 6 Ave, 20-093 Lublin, Poland; (J.W.-M.); (M.P.)
| | - Monika Madej
- Faculty of Mechatronics and Mechanical Engineering, Kielce University of Technology, al. Tysiąclecia Państwa Polskiego 7, 25-314 Kielce, Poland;
| |
Collapse
|
4
|
Loguercio AD, Carpio-Salvatierra B, Ñaupari-Villasante R, Wendlinger M, Armas-Vega A, Cavagnaro S, León A, Aliaga-Galvez R, Gutiérrez MF. Clinical evaluation of a new chemically-cured bulk-fill composite in posterior restorations: 6-month multicenter double-blind randomized clinical trial. J Dent 2024; 149:105246. [PMID: 39025426 DOI: 10.1016/j.jdent.2024.105246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2024] [Revised: 07/12/2024] [Accepted: 07/15/2024] [Indexed: 07/20/2024] Open
Abstract
OBJECTIVE To evaluate the postoperative sensitivity (POS), as well as the clinical performance of posterior restorations using a new chemically-cured bulk-fill composite (Stela Automix and Stela Capsule, SDI) comparing with a light-cured bulk-fill composite after 6 months. METHODS Fifty-five participants with at least three posterior teeth needing restoration were recruited. A total of 165 restorations were performed on Class I or Class II cavities. After the application of Stela primer, the chemically-cured composite (Stela Automix or Stela Capsule) was inserted. For the light-cured composite group, a universal adhesive (Scotchbond Universal) was applied with a bulk-fill composite (Filtek One). Participants were evaluated for spontaneous and stimulated POS in the baseline, after 48 h, 7 days, and 6 months. Additionally, each restoration was assessed using the updated version of FDI criteria after 6 months. The differences in the proportions of the groups were compared by Cochran test statistics (α = 0.05). RESULTS Both chemically-cured composites showed a lower risk of POS compared to the light-cured composite at baseline and up to 48 h (p < 0.04). A significantly lower surface luster and texture was observed for the Stela Capsule composite compared to the light-cured bulk-fill composite (baseline and 6 months; p = 0.03). A significant color mismatch was observed for the light-cured bulk-fill composite compared to the chemically-cured composites (baseline and 6 months; p = 0.03). No significant differences were observed in any other item evaluations (p > 0.05). CONCLUSION Chemically-cured composites exhibit lower postoperative sensitivity and less color mismatch compared to a light-cured bulk-fill composite after 6 months of clinical service. CLINICAL SIGNIFICANCE The chemically-cured composites appear to be an appealing option for restoring posterior teeth, as they exhibit lower postoperative sensitivity compared to a light-cured bulk-fill composite, both at baseline and up to 48 h, and less color mismatch.
Collapse
Affiliation(s)
- Alessandro D Loguercio
- State University of Ponta Grossa, School of Dentistry, Ponta Grossa/PR, 84030-000, Brazil; Facultad de Ciencias de la Salud, Carrera de Odontologia, Universidad De Los Hemisferios, Quito 170147, Ecuador
| | - B Carpio-Salvatierra
- State University of Ponta Grossa, School of Dentistry, Ponta Grossa/PR, 84030-000, Brazil
| | - R Ñaupari-Villasante
- State University of Ponta Grossa, School of Dentistry, Ponta Grossa/PR, 84030-000, Brazil
| | - M Wendlinger
- State University of Ponta Grossa, School of Dentistry, Ponta Grossa/PR, 84030-000, Brazil
| | - Ana Armas-Vega
- Facultad de Ciencias de la Salud, Carrera de Odontologia, Universidad De Los Hemisferios, Quito 170147, Ecuador
| | - S Cavagnaro
- Universidad de los Andes, Chile, Facultad de Odontología, Santiago 7550000, Chile
| | - A León
- Universidad de los Andes, Chile, Facultad de Odontología, Santiago 7550000, Chile
| | - R Aliaga-Galvez
- Universidad de los Andes, Chile, Facultad de Odontología, Santiago 7550000, Chile
| | - M F Gutiérrez
- Universidad de los Andes, Chile, Facultad de Odontología, Santiago 7550000, Chile.
| |
Collapse
|
5
|
Hatipoğlu Ö, Par M, Pertek Hatipoğlu F. Comparison of degree of conversion performance of bulk-fill resin composites: A systematic review and network meta-analysis of in vitro studies. J Dent 2024; 149:105289. [PMID: 39103073 DOI: 10.1016/j.jdent.2024.105289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2024] [Revised: 07/13/2024] [Accepted: 08/02/2024] [Indexed: 08/07/2024] Open
Abstract
OBJECTIVES To systematically compile data on the degree of conversion (DC) for bulk-fill composites using a network meta-analysis. METHODS A systematic search for in vitro studies of DC of bulk-fill composites was performed in PubMed, Web of Science, Scopus, and Open Grey. Risk of bias within studies and due to missing evidence was assessed using the Joanna Briggs Institute scoring system and ROB-MEN tool, respectively. The primary outcome was the DC of bulk-fill composites. Surface Under the Cumulative Ranking curve (SUCRA) was used to rank relative performance. Inconsistencies in the model were investigated to ensure its validity and the level of confidence in the network meta-analysis (CINeMA) was assessed. RESULTS A total of 28 studies were included in the quantitative analysis. The average DC values (%) for 0-h/top, 0-h/bottom, 24-h/top, and 24-h/bottom were 59.09, 57.14, 66.73, and 63.87, respectively. According to their SUCRA ranking, the best-performing composites were: SonicFill, Venus Bulk Fill, and SDR (0-h/top), Reveal HD, i-Flow Bulk Fill, and Venus Bulk- Fill (0-h/bottom), Venus Bulk Fill, SDR, and QuiXfil (24-h/top), and Venus Bulk Fill, Aura Bulk Fill, and i-Flow Bulk Fill (24-h/bottom). Incoherence between direct and indirect evidence was identified as the most significant factor affecting confidence. CONCLUSIONS DC values of bulk-fill composites were within the range commonly reported for previous generations of "conventional" composites, with flowable composites tending to perform better than sculptable composites. High variability in DC data was observed, which may be attributed to incompletely understood methodological differences. CLINICAL SIGNIFICANCE DC is a fundamental parameter that influences multiple mechanical and biological properties of resin composites and is particularly relevant for the group of bulk-fill composites that are designed for use in thick layers.
Collapse
Affiliation(s)
- Ömer Hatipoğlu
- Department of Restorative Dentistry, Nigde Ömer Halisdemir University, Niğde, Turkey
| | - Matej Par
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, Zagreb, Croatia.
| | | |
Collapse
|
6
|
Algamaiah H, Alshabib A, Algomaiah M, Yang J, Watts DC. Diversity of short-term DC outcomes in bulk-fill RBCs subjected to a 3 s high-irradiance protocol. Dent Mater 2024:S0109-5641(24)00256-2. [PMID: 39227233 DOI: 10.1016/j.dental.2024.08.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2024] [Revised: 08/02/2024] [Accepted: 08/23/2024] [Indexed: 09/05/2024]
Abstract
OBJECTIVES To determine the short-term (5 min) initial effects of a high-irradiance light-curing (LC) protocol on light transmission (LT%), radiant exposure (RE) and degree of conversion (DC%) of different bulk-fill resin-based composites (RBCs). MATERIALS AND METHODS Six bulk-fill composites with different viscosities were investigated: OBF (One Bulk Fill, 3 M), EB (Estelite bulkfill,Tokuyama), PFill, PFlow, ECeram and EFlow (PowerFill, Poweflow, Tetric EvoCeram bulkfill, Tetric Evoflow bulkfill, Ivoclar), subjected to different LC protocols: one ultra-high-intensity (3 W/cm2 -3 s via PowerCure LCU) and two conventional (1.2 W/cm2 -10 s and 20 s via PowerCure and Elipar S10 LCUs). Specimens (n = 5) were polymerized within their molds (ϕ5 mm × 4 mm depth) to determine LT% and RE at 4 mm using a MARC-LC spectrometer. For real-time DC% measurements by FTIR, similar molds were utilized. Data were analyzed by one-way ANOVA and Tukey post-hoc tests at 5 % significance. RESULTS Regardless of the applied LC protocols, OBF and low-viscosity RBCs (EB, PFlow and EFlow) had the lowest and highest LT%, RE, DC% and RPmax, respectively. RE results of all RBCs were in the same sequence: Elipar-20 s > PCure-10 s > PCure-3 s. DC% of PFill and PFlow displayed no significant difference between the applied LC protocols (p > 0.05). The polymerization kinetic in all materials was well described by an exponential sum function (r2 varied between 0.85 and 0.98), showing a faster polymerization with the PCure-3 s protocol. SIGNIFICANCE The measurement of LT% and DC% at 5 min gave an insight into the developing polymerization process. The initial response of these bulk-fill composite to a high-irradiation protocol varied depending on their composition and viscosity, being faster for low viscosity materials. Nevertheless, even though multiple resin composites are designed to be efficient during photopolymerization, care should be taken when selecting materials/curing protocol.
Collapse
Affiliation(s)
- Hamad Algamaiah
- Department of Restorative Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh 11545, Saudi Arabia.
| | - Abdulrahman Alshabib
- Department of Restorative Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh 11545, Saudi Arabia
| | - Muadh Algomaiah
- Department of Pediatric Dentistry and Orthodontics, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh 11545, Saudi Arabia
| | - Jiawei Yang
- Department of prosthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, China; National Clinical Research Center for Oral Diseases, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - David C Watts
- Biomaterials Science, Division of Dentistry, School of Medical Sciences, University of Manchester, UK; Photon Science Institute, University of Manchester, UK.
| |
Collapse
|
7
|
Ma X, Zhang X, Huang X, Liu F, He J, Mai S. Performance of low shrinkage Bis-EFMA based bulk-fill dental resin composites. Dent Mater 2024; 40:1378-1389. [PMID: 38902144 DOI: 10.1016/j.dental.2024.06.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2024] [Revised: 06/18/2024] [Accepted: 06/18/2024] [Indexed: 06/22/2024]
Abstract
OBJECTIVES The purpose of this study was evaluating the performance of new Bis-EFMA based bulk-fill composites with common methacrylate based composites and commercial dental composites. METHODS The Bis-EFMA monomer was synthesized and the novel Bis-EFMA based bulk-fill composites were prepared. The resin composite samples were co-cultured with human gingival epithelial cells and human dental pulp stem cells to test the biocompatibility. The edge adaptation was observed under a combination of stereoscope and scanning electron microscope. The internal hardness was measured using a Vickers microhardness tester after one-time filling of cavities prepared in extracted teeth. After friction and wear test on the surface of the resin composites, the surface morphology and volume wear of each group were measured by the optical profilometer. The color stability was measured by a colorimeter. RESULTS Direct contact with human gingival epithelial cells and human dental pulp stem cells did not cause significant changes in their growth density and morphology, indicating good biocompatibility of Bis-EFMA group (p > 0.05). The continuous margin proportion of the Bis-EFMA group was as good as commercial bulk-fill composites (p > 0.05). The sectional microhardness results showed that the Bis-EFMA group had the highest microhardness. After the friction and wear test, the volume wear of the Bis-EFMA group was minimal, indicating its good wear resistance and mechanical strength. Color changes in all resin groups after 28 days of immersion were within the clinically acceptable range. SIGNIFICANCE The addition of Bis-EFMA demonstrated excellent biocompatibility, edge adaptation and color stability comparable to commonly used clinical bulk-fill composites, along with preferable mechanical strength, friction and wear resistance. Bis-EFMA based bulk-fill composites have the potential to be employed as a bulk filling material in commercial dental composite applications.
Collapse
Affiliation(s)
- Xinyue Ma
- Hospital of Stomatology, Sun Yat-sen University, Guangzhou, China; Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China; Institute of Stomatology, Sun Yat-sen University, Guangzhou, China.
| | - Xiaoqing Zhang
- College of Materials Science and Engineering, South China University of Technology, Guangzhou, China.
| | - Xiangya Huang
- Hospital of Stomatology, Sun Yat-sen University, Guangzhou, China; Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China; Institute of Stomatology, Sun Yat-sen University, Guangzhou, China.
| | - Fang Liu
- College of Materials Science and Engineering, South China University of Technology, Guangzhou, China.
| | - Jingwei He
- College of Materials Science and Engineering, South China University of Technology, Guangzhou, China.
| | - Sui Mai
- Hospital of Stomatology, Sun Yat-sen University, Guangzhou, China; Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China; Institute of Stomatology, Sun Yat-sen University, Guangzhou, China.
| |
Collapse
|
8
|
Lee H, Kim YJ, Yang YJ, Lee JH, Lee HH. Development of antibacterial dual-cure dental resin composites via tetrapod-shaped zinc oxide incorporation. Dent Mater 2024:S0109-5641(24)00223-9. [PMID: 39117497 DOI: 10.1016/j.dental.2024.07.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 06/25/2024] [Accepted: 07/24/2024] [Indexed: 08/10/2024]
Abstract
OBJECTIVES This study aimed to evaluate the effects of incorporating the 0-20 wt% tetrapod-shaped zinc oxide (tZnO) whiskers on the mechanical, antibacterial, and cytotoxic properties exhibited by experimental dual-cure resin composites. METHODS Commercially obtained tZnO whiskers underwent surface modification using 3-methacryloxypropyltrimethoxysilane (γ-MPS). Subsequently, four groups of resin composites containing 0, 5, 10, and 20 wt% silanized tZnO along with barium borosilicate glass (BaBSG) fillers were fabricated while maintaining total filler loading at 60 wt%. Mechanical properties were examined utilizing specimens produced adhering to ISO 4049:2019 guidelines where applicable. Depth of cure was quantified immediately, while three-point flexural strength, flexural modulus, fracture toughness, Vickers hardness, compressive strength, and diametral tensile strength were assessed after 24 h of storage in 37 °C distilled water. Planktonic bacteria of Streptococcus mutans (S. mutans) were cultured and tested for antibacterial activity using disk diffusion and microbial anti-adhesion assays. Cytotoxicity was examined by preparing extracts from specimens in a cell culture medium and exposing stem cells from human exfoliated deciduous teeth (SHED) to serial dilutions of these extracts, then assessing cell viability and survival using CCK-8 assay and live/dead staining. RESULTS Elevating tZnO loading yielded significant reductions in depth of cure, compressive (from 296.4 to 254.6 MPa), and diametral tensile strength (from 42.7 to 31.0 MPa), while flexural strength (91.3-94.1 MPa), flexural modulus (6.4-6.6 GPa), fracture toughness (0.96-1.04 MPa·m0.5), and Vickers hardness (36.5-37.4 kgf·mm-2) remained the same. Composites integrating tZnO displayed markedly enhanced antibacterial activity against S. mutans, based on anti-adhesion tests and live/dead staining. No cytotoxicity was observed for SHED treated with extracts from resin composites possessing up to 20 wt% tZnO whiskers. SIGNIFICANCE This study demonstrates that incorporating up to 20 wt% silanized tZnO in place of traditional barium glass particles appreciably enhances dual-cure resin composite antibacterial function against S. mutans without compromising mechanical properties.
Collapse
Affiliation(s)
- Hwalim Lee
- Department of Biomaterials Science, College of Dentistry, Dankook University, 119 Dandae-ro, Cheonan 31116, the Republic of Korea; Institute of Tissue Regeneration Engineering (ITREN), Dankook University, 119 Dandae-ro, Cheonan 31116, the Republic of Korea.
| | - Yu-Jin Kim
- Department of Biomaterials Science, College of Dentistry, Dankook University, 119 Dandae-ro, Cheonan 31116, the Republic of Korea; Institute of Tissue Regeneration Engineering (ITREN), Dankook University, 119 Dandae-ro, Cheonan 31116, the Republic of Korea.
| | - Ye-Jin Yang
- Institute of Tissue Regeneration Engineering (ITREN), Dankook University, 119 Dandae-ro, Cheonan 31116, the Republic of Korea.
| | - Jung-Hwan Lee
- Department of Biomaterials Science, College of Dentistry, Dankook University, 119 Dandae-ro, Cheonan 31116, the Republic of Korea; Institute of Tissue Regeneration Engineering (ITREN), Dankook University, 119 Dandae-ro, Cheonan 31116, the Republic of Korea.
| | - Hae-Hyoung Lee
- Department of Biomaterials Science, College of Dentistry, Dankook University, 119 Dandae-ro, Cheonan 31116, the Republic of Korea; Institute of Tissue Regeneration Engineering (ITREN), Dankook University, 119 Dandae-ro, Cheonan 31116, the Republic of Korea.
| |
Collapse
|
9
|
Ribeiro M, Maucoski C, Price RB, Soares CJ. Effect of a 3-second Off-label Exposure on the Depth of Cure of Eight Resin-based Composites. Oper Dent 2024; 49:421-431. [PMID: 38978305 DOI: 10.2341/23-155-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/01/2024] [Indexed: 07/10/2024]
Abstract
OBJECTIVES This study evaluated the depth of cure (DoC) of eight resin-based composites (RBCs) photocured using one multipeak light-curing unit (LCU) on the standard output setting for the manufacturer's RBC recommended exposure time and at a higher irradiance for 3 seconds. METHODS Three conventional RBCs: Tetric EvoCeram (Evo), Tetric N-Ceram (Cer), Tetric Prime (Pri); and five bulk-fill: Tetric N-Ceram Bulk Fill (CerBF), Opus Bulk Fill APS (OpusBF), Opus Bulk Fill Flow APS (OpusF), Tetric PowerFill (PFill) and Tetric PowerFlow (PFlow) were examined. Only PFill and PFlow are formulated to be photocured in 3 seconds. The RBCs were packed into a metal mold and photocured using a Bluephase PowerCure LCU for the RBC manufacturer's recommended exposure time on the standard mode and using the 3-second high irradiance mode. After photocuring, the specimens were immersed in a solvent for 1 hour. The length of the remaining RBC was measured and divided by 2. Data were analyzed using two-way analysis of variance (ANOVA) followed by the Tukey post hoc multiple comparison test (α=0.05). RESULTS There was no significant difference in the DoC values for PFill and PFlow when photocured using the 3-second high irradiance protocol compared to the lower irradiance standard mode protocol. All other RBCs had significantly lower DoC values (p<0.001) when photocured off-label using the 3-second high irradiance mode. CONCLUSION Of the eight RBCs tested, only PFill and PFlow achieved the same DoC when the high irradiance 3-second curing method was used compared to when their longer lower irradiance protocol was used.
Collapse
Affiliation(s)
- Mth Ribeiro
- Maria Tereza Hordones Ribeiro DDS, MSc, PhD student, Department of Operative Dentistry and Dental Materials, Dental School, Federal University of Uberlândia, Minas Gerais, Brazil
| | - C Maucoski
- Cristiane Maucoski, DDS, MSc, PhD, Department of Operative Dentistry and Dental Materials, Dental School, Federal University of Ponta Grossa, Ponta Grossa, Paraná, Brazil
| | - R B Price
- Richard Bengt Price, DDS, MS, PhD, professor, Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
| | - C J Soares
- *Carlos José Soares, DDS, MSc, PhD, professor, Department of Operative Dentistry and Dental Materials, Biomechanics Research Center, Federal University of Uberlândia, Minas Gerais, Brazil
| |
Collapse
|
10
|
Chen WC, Lai TW, Li CL, Chen TYF, Chang CH, Chuang SF. Assessments of polymerization shrinkage by optical coherence tomography-based digital image correlation analysis-Part II: Effects of restorative composites. Dent Mater 2024; 40:1064-1071. [PMID: 38777732 DOI: 10.1016/j.dental.2024.05.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 04/27/2024] [Accepted: 05/03/2024] [Indexed: 05/25/2024]
Abstract
OBJECTIVES To examine the polymerization shrinkage of different resin-based composite (RBC) restorations using optical coherence tomography (OCT) image-based digital image correlation (DIC) analysis. METHODS The refractive index (RI) of three RBCs, Filtek Z350XT (Z350), Z350Flowable (Z350F), and BulkFill Posterior (Bulkfill), was measured before and after polymerization to calibrate their axial dimensions under OCT. Class I cavities were prepared in bovine incisors and individually filled with these RBCs under nonbonded and bonded conditions. A series of OCT images of these restorations were captured during 20-s light polymerization and then input into DIC software to analyze their shrinkage behaviors. The interfacial adaptation was also examined using these OCT images. RESULTS The RI of the three composites ranged from 1.52 to 1.53, and photopolymerization caused neglectable increases in the RI values. For nonbonded restorations, Z350F showed maximal vertical displacements on the top surfaces (-16.75 µm), followed by Bulkfill (-8.81 µm) and Z350 (-5.97 µm). In their bonded conditions, all showed increased displacements. High variations were observed in displacement measurements on the bottom surfaces. In the temporal analysis, the shrinkage of nonbonded Z350F and Bulkfill decelerated after 6-10 s. However, Z350 showed a rebounding upward displacement after 8.2 s. Significant interfacial gaps were found in nonbonded Z350 and Z350F restorations. SIGNIFICANCE The novel OCT image-based DIC analysis provided a comprehensive examination of the shrinkage behaviors and debonding of the composite restorations throughout the polymerization process. The flowable composite showed the highest shrinkage displacements. Changes in the shrinkage direction may occur in nonbonded conventional composite restorations.
Collapse
Affiliation(s)
- Wei-Chi Chen
- School of Dentistry and Institute of Oral Medicine, National Cheng Kung University, Tainan, Taiwan; Department of Dentistry, Sin-Lau Hospital, Tainan, Taiwan
| | - Ting-Weng Lai
- School of Dentistry and Institute of Oral Medicine, National Cheng Kung University, Tainan, Taiwan; Department of Stomatology, National Cheng Kung University Hospital, Tainan, Taiwan
| | - Chia-Ling Li
- School of Dentistry and Institute of Oral Medicine, National Cheng Kung University, Tainan, Taiwan
| | - Terry Yuan-Fang Chen
- Department of Mechanical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Chih-Han Chang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Shu-Fen Chuang
- School of Dentistry and Institute of Oral Medicine, National Cheng Kung University, Tainan, Taiwan; Department of Stomatology, National Cheng Kung University Hospital, Tainan, Taiwan.
| |
Collapse
|
11
|
Novta E, Pantelić D, Blažić L, Tóth E, Cvejić Ž, Grujić D, Savić-Šević S, Lainović T. Impact of optical fiber-based photo-activation on dental composite polymerization. J Dent 2024; 145:104998. [PMID: 38636650 DOI: 10.1016/j.jdent.2024.104998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 04/04/2024] [Accepted: 04/16/2024] [Indexed: 04/20/2024] Open
Abstract
OBJECTIVES The study aimed to introduce a novel two-step optical fiber-based photo-activation of dental resin-based composites (RBCs) for reducing polymerization shrinkage stress (PSS). METHODS Proposed protocol design - in the first step, two flexible plastic optical fibers connected to a dental light curing unit (LCU), were used as light guides inserted into the filling to initiate low-irradiance polymerization from within; in the second step, fibers were extracted and remaining voids were filled with RBC, followed by conventional high-irradiance curing to finalize polymerization. Three bulk-fill RBCs were tested (Beautifil-Bulk Restorative, Filtek Bulk-fill Posterior, Tetric PowerFill) using tooth cavity models. Three non-invasive examination techniques were employed: Digital Holographic Interferometry, Infrared Thermography, and Raman spectroscopy for monitoring model deformation, RBC temperature change, and degree of conversion (DC), respectively. A control group (for each examined RBC) underwent conventional photo-activation. RESULTS The experimental protocol significantly reduced model deformation by 15 - 35 %, accompanied by an 18 - 54 % reduction in RBC temperature change, emphasizing the impact of thermal shrinkage on PSS. Real-time measurements of deformation and temperature provided indirect insights into reaction dynamics and illuminated potential mechanisms underlying PSS reduction. After a 24-hour dark-storage period, DC outcomes comparable to conventional curing were observed, affirming the clinical applicability of the method. CONCLUSIONS Protocol involving the use of two 1.5 mm fibers in the first step (300 mW/cm2 x 10 s), followed by a second conventional curing step (1000 mW/cm2 x 10 s), is recommended to achieve the desired PSS reduction, while maintaining adequate DC and ensuring efficient clinical application. CLINICAL SIGNIFICANCE Obtained PSS reduction offers promise in potentially improving the performance of composite restorations. Additionally, leveraging the flexibility of optical fibers improves light guide approach for restorations on posterior teeth. Meanwhile, implementation in clinical practice is easily achievable by coupling the fibers with commercial dental LCUs using the provided plastic adapter.
Collapse
Affiliation(s)
- Evgenije Novta
- University of Novi Sad, Faculty of Medicine, School of Dental Medicine, Hajduk Veljkova 12, Novi Sad, Serbia.
| | - Dejan Pantelić
- University of Belgrade, Institute of Physics, Pregrevica 118, Belgrade, Serbia
| | - Larisa Blažić
- University of Novi Sad, Faculty of Medicine, School of Dental Medicine, Hajduk Veljkova 12, Novi Sad, Serbia; Dental clinic of Vojvodina, Hajduk Veljkova 12, Novi Sad, Serbia
| | - Elvira Tóth
- University of Novi Sad, Faculty of Sciences, Department of Physics, Trg Dositeja Obradovića 3, Novi Sad, Serbia
| | - Željka Cvejić
- University of Novi Sad, Faculty of Sciences, Department of Physics, Trg Dositeja Obradovića 3, Novi Sad, Serbia
| | - Dušan Grujić
- University of Belgrade, Institute of Physics, Pregrevica 118, Belgrade, Serbia
| | | | - Tijana Lainović
- University of Novi Sad, Faculty of Medicine, School of Dental Medicine, Hajduk Veljkova 12, Novi Sad, Serbia
| |
Collapse
|
12
|
Klarić E, Bosnić JV, Par M, Tarle Z, Marovic D. One-Year Evaluation of High-Power Rapid Curing on Dentin Bond Strength. MATERIALS (BASEL, SWITZERLAND) 2024; 17:2297. [PMID: 38793364 PMCID: PMC11122907 DOI: 10.3390/ma17102297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 05/07/2024] [Accepted: 05/10/2024] [Indexed: 05/26/2024]
Abstract
This study investigated the effect of 3 s light-curing with a high-power LED curing unit on the shear bond strength of bulk-fill composites. Four bulk-fill composites were bonded to dentin with a universal adhesive (Scotchbond Universal Plus): two materials designed for rapid curing (Tetric PowerFill and Tetric PowerFlow) and two controls (Filtek One Bulk Fill Restorative and SDR Plus Bulk Fill Flowable). The 4 mm composite layer was light-cured with Bluephase PowerCure for 20 s at 1000 mW/cm2 ("20 s") or for 3 s at 3000 mW/cm2 ("3 s"). The samples were stored at 37 °C in distilled water and tested after 1, 6 and 12 months. The samples polymerised in the "3 s" mode had statistically similar or higher bond strength than the samples cured in "20 s" mode, except for the Tetric PowerFlow (1 month) and SDR+ (6 month). The flowable materials Tetric PowerFlow and SDR Plus initially showed the highest values in the "3 s" and "20 s" groups, which decreased after 12 months. The bond strength was statistically similar for all materials and curing protocols after 12 months, except for Tetric PowerFill cured with the "3 s" protocol (21.22 ± 5.0 MPa), which showed the highest value. Tetric PowerFill showed the highest long-term bond strength. While "3 s" curing resulted in equal or better shear bond strength, its use can only be recommended for a material with an AFCT agent such as Tetric PowerFill.
Collapse
Affiliation(s)
- Eva Klarić
- Department of Endodontics and Restorative Dentistry, University of Zagreb School of Dental Medicine, 10000 Zagreb, Croatia; (E.K.); (M.P.); (Z.T.)
| | | | - Matej Par
- Department of Endodontics and Restorative Dentistry, University of Zagreb School of Dental Medicine, 10000 Zagreb, Croatia; (E.K.); (M.P.); (Z.T.)
| | - Zrinka Tarle
- Department of Endodontics and Restorative Dentistry, University of Zagreb School of Dental Medicine, 10000 Zagreb, Croatia; (E.K.); (M.P.); (Z.T.)
| | - Danijela Marovic
- Department of Endodontics and Restorative Dentistry, University of Zagreb School of Dental Medicine, 10000 Zagreb, Croatia; (E.K.); (M.P.); (Z.T.)
| |
Collapse
|
13
|
Chen TA, Lu PY, Lin PY, Chi CW, Cheng HY, Lai YJ, Wang F, Chiang YC. Effects of ceramic thickness, ceramic translucency, and light transmission on light-cured bulk-fill resin composites as luting cement of lithium disilicate based-ceramics. J Prosthodont Res 2024; 68:255-263. [PMID: 37197947 DOI: 10.2186/jpr.jpr_d_22_00304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
PURPOSE To assess the effects of ceramic thickness, ceramic translucency, and light transmission on restorative composites used as luting cement for lithium disilicate-based ceramics. METHODS Four luting types of cement were tested (n=8); a dual-cured resin cement (Multilink N), a light-cured conventional flowable composite (Tetric N-Flow), and two light-cured bulk-fill flowable composites (Tetric N-Flow Bulk Fill and X-tra base). The 20 s- or 40 s-light (1000 mW/cm2) was transmitted through 1- or 2-mm-thick high- or low-translucency (HT- or LT-) ceramic discs (IPS e.Max press) to reach the 1-mm-thick luting cement. Light transmitted to cement without ceramic served as a control. Vickers hardness number (VHN), flexural strength (FS), fractography, and degree of conversion (DC) were evaluated. One-way and multi-way analysis of variance was conducted to determine the effects of factors on VHN and FS. RESULTS Ceramic thickness, light transmission time, and cement type significantly affected the VHN of the luting cement (P < .000). Only Multilink N (LT- and HT-1mm) and Tetric N-Flow (HT-1mm) reached 90% VHN of corresponding control by 20 s-light transmissions, but Tetric N-Flow exhibited lowest VHN and approximately 1/3-1/2 VHN of Multilink N (P < 0.05). X-tra base expressed superior physicochemical properties to Tetric N-Flow Bulk Fill (P < 0.05) and reached >90% VHN of control in all conditions with 40 s-light transmissions except for LT-2 mm. DC, FS, and fractography supported these findings. CONCLUSIONS The light-cured bulk-fill composite served as a luting cement for lithium-disilicate-based ceramics in a product-dependent manner. Light transmission time is crucial to ensure sufficient luting cement polymerization.
Collapse
Affiliation(s)
- Ting-An Chen
- Division of Restorative and Aesthetic Dentistry, Dental Department, National Taiwan University Hospital, Taipei, Taiwan
| | - Pei-Ying Lu
- Division of Restorative and Aesthetic Dentistry, Dental Department, National Taiwan University Hospital, Taipei, Taiwan
- Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University and National University Hospital, Taipei, Taiwan
| | - Po-Yen Lin
- Department of Dentistry, School of Dentistry, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Chih-Wen Chi
- Department of Dentistry, National Taiwan University Hospital Hsin-Chu Branch, Hsinchu City, Taiwan
| | - Hon Yin Cheng
- Division of Restorative and Aesthetic Dentistry, Dental Department, National Taiwan University Hospital, Taipei, Taiwan
| | - Yu-Jung Lai
- Division of Restorative and Aesthetic Dentistry, Dental Department, National Taiwan University Hospital, Taipei, Taiwan
- Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University and National University Hospital, Taipei, Taiwan
| | - Fajen Wang
- Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University and National University Hospital, Taipei, Taiwan
| | - Yu-Chih Chiang
- Division of Restorative and Aesthetic Dentistry, Dental Department, National Taiwan University Hospital, Taipei, Taiwan
- Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University and National University Hospital, Taipei, Taiwan
- Molecular Imaging Center, National Taiwan University, Taipei, Taiwan
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| |
Collapse
|
14
|
Sampaio CS, Abreu JLBD, Kornfeld B, Silva EMD, Giannini M, Hirata R. Short curing time bulk fill composite systems: volumetric shrinkage, degree of conversion and Vickers hardness. Braz Oral Res 2024; 38:e030. [PMID: 38597548 PMCID: PMC11376680 DOI: 10.1590/1807-3107bor-2024.vol38.0030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Accepted: 12/18/2021] [Indexed: 04/11/2024] Open
Abstract
This study aimed to evaluate volumetric polymerization shrinkage, degree of conversion and Vickers hardness of four bulk-fill resin composites light-activated with their dedicated light curing units (LCUs). Four groups were evaluated, according to the type of composite and curing mode: Tetric EvoCeram Bulk-fill (TEBO) and Tetric EvoFlow Bulk-fill (TEBF) were light-activated with Bluephase Style 20i (20s, in high-mode), while Tetric Powerfill (TEPO) and Tetric Powerflow (TEPF) were light-activated with Bluephase PowerCure (3s). Volumetric polymerization shrinkage test (n = 6) was performed in standardized box-shaped class-I cavities of extracted third molars (4 x 4 x 4 mm). Teeth were scanned before and after resin composite application by micro-computed tomography, and acquired data were evaluated with Amira software. Degree of conversion (n = 5) was evaluated at the top and bottom surfaces of composite cylindric samples (4 mm diameter, 4 mm thickness) using an FT-IR spectrometer (spectra between 1,500 and 1,800 cm-1, 40 scans at a resolution of 4 cm-1). Three Vickers indentations (50 g / 15 s), spaced 500 μm apart, were performed on the top and bottom composite surfaces and averaged. One-way ANOVA was used for data evaluation. TEPF showed the lowest volumetric polymerization shrinkage (p < 0.05), while the other composites were not significantly different within each other (p > 0.05). All materials presented a significant decrease in degree of conversion and Vickers hardness when compared top to bottom surfaces (p < 0.05). Bottom to top surface ratios for degree of conversion ranged from 0.8 (TEBO and TEPO) to 0.9 (TEBF and TEPF), and from 0.4 (TEPO) to 0.7 (TEBF and TEPF) for hardness. In conclusion, resinous materials present a decrease in hardness and degree of conversion from top to bottom even when a higher power is used, while the flowable material TEPF showed the lowest volumetric shrinkage values compared to the other materials.
Collapse
Affiliation(s)
- Camila Sobral Sampaio
- New York University, College of Dentistry, Advanced Clinical Fellowship in Aesthetics, Operative and Digital Dentistry, New York, NY, USA
| | - João Luiz Bittencourt de Abreu
- Universidade Federal Fluminense - UFF, School of Dentistry, Analytical Laboratory of Restorative Biomaterials - LABiom-R, Niteroi, RJ, Brazil
| | - Batsheva Kornfeld
- New York University, College of Dentistry, Department of Biomaterials and Biomimetics, New York, NY, USA
| | - Eduardo Moreira da Silva
- Universidade Federal Fluminense - UFF, School of Dentistry, Analytical Laboratory of Restorative Biomaterials - LABiom-R, Niteroi, RJ, Brazil
| | - Marcelo Giannini
- Universidade Estadual de Campinas - Unicamp, Piracicaba Dental School, Department of Restorative Dentistry, Piracicaba, SP, Brazil
| | - Ronaldo Hirata
- New York University, College of Dentistry, Department of Biomaterials and Biomimetics, New York, NY, USA
| |
Collapse
|
15
|
Néma V, Kunsági-Máté S, Őri Z, Kiss T, Szabó P, Szalma J, Fráter M, Lempel E. Relation between internal adaptation and degree of conversion of short-fiber reinforced resin composites applied in bulk or layered technique in deep MOD cavities. Dent Mater 2024; 40:581-592. [PMID: 38368136 DOI: 10.1016/j.dental.2024.02.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 01/08/2024] [Accepted: 02/12/2024] [Indexed: 02/19/2024]
Abstract
OBJECTIVE The purpose was to evaluate the degree of conversion (DC), internal adaptation (IA) and closed porosity (CP) of short-fiber reinforced resin composites (SFRC) associated with layered or bulk restorative procedures in deep MOD cavities. METHODS Eighty third molars with standardized MOD cavities (5-mm-depth, 2.5-mm-width) were randomly divided into four groups and restored as follows: 1) bulk SFRC; 2) layered SFRC; 3) flowable bulk-fill resin-based composites (RBC); 4) layered conventional RBC. After one-month wet storage the samples were subjected to micro-computed tomography measurements and scanning electron microscopy to assess the IA and CP. Micro-Raman spectroscopy was used to determine the DC in different depths. Data were subjected to ANOVA and Tukey's post-hoc test, multivariate analysis and partial eta-squared statistics (p < 0.05). Pearson correlation coefficient was determined to assess the relationship among the parameters of interest. RESULTS Gap/total interface volume ratio ranged between 0.22-0.47%. RBCs applied in bulk revealed significantly lower gap volume (p < 0.001) and CP (p < 0.05). Each group showed complete detachment on the pulpal and partial on the lateral walls, except for group3. While the highest DC% was achieved by the conventional RBC (87.2%), followed by the flowable bulk-fill (81.2%), SFRC provided the best bottom to top DC ratio (bulk: 96.4%, layered: 98.7%). The effect of factors studied (RBC type, filling technique) on IA and DC was significant (p < 0.001). SIGNIFICANCE Bulk placement of RBCs exhibited lower interfacial gap volume and achieved satisfactory DC without significant correlation between these parameters. Incremental insertion of SFRC had no advantage over bulk placement in terms of IA and DC.
Collapse
Affiliation(s)
- Viktória Néma
- Department of Operative and Esthetic Dentistry, Faculty of Dentistry, University of Szeged, Tisza Lajos Blvd 64-66, 6720 Szeged, Hungary
| | - Sándor Kunsági-Máté
- Department of Organic and Pharmacological Chemistry, University of Pécs Medical School, Faculty of Pharmacy, Honvéd street 1, 7624 Pécs, Hungary; János Szentágothai Research Center, University of Pécs, Ifjúság Street 12, 7624 Pécs, Hungary
| | - Zsuzsanna Őri
- Department of Nutritional Sciences and Dietetics, University of Pécs, Faculty of Health Sciences, Vörösmarty Street 4, 7621 Pécs, Hungary; Department of Physical Chemistry and Materials Science, University of Pécs, Faculty of Sciences, Ifjúság Street 6, 7624 Pécs, Hungary
| | - Tamás Kiss
- Department of Pharmacology and Pharmacotherapy, University of Pécs Medical School, Szigeti Street 12, 7624 Pécs, Hungary
| | - Péter Szabó
- János Szentágothai Research Center, University of Pécs, Ifjúság Street 12, 7624 Pécs, Hungary
| | - József Szalma
- Department of Oral and Maxillofacial Surgery, University of Pécs Medical School, Tüzér Street 1, 7623 Pécs, Hungary
| | - Márk Fráter
- Department of Operative and Esthetic Dentistry, Faculty of Dentistry, University of Szeged, Tisza Lajos Blvd 64-66, 6720 Szeged, Hungary
| | - Edina Lempel
- Department of Restorative Dentistry and Periodontology, University of Pécs Medical School, Tüzér Street 1, 7623 Pécs, Hungary.
| |
Collapse
|
16
|
Lee CH, Lee IB. Three methods to measure the photopolymerization kinetics for different radiant emittance and composite type. Dent Mater J 2024; 43:207-215. [PMID: 38296511 DOI: 10.4012/dmj.2023-197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/02/2024]
Abstract
Photopolymerization kinetics affects the curing time, degree of conversion, polymerization shrinkage, and mechanical properties of composites. The aim of this study was to compare three methods (temperature, heat flow, and polymerization shrinkage) for photopolymerization kinetics measurement of composites. The photopolymerization kinetics of four composites (2 packable and 2 flowable) were measured with an LED light for 20 s (radiant emittance: 2,100 mW/cm2). For the two packable composites, photopolymerization kinetics was measured with varying the radiant emittance and exposure time. For each measurement method, peak times were determined as the time when maximum temperature rise, heat flow, and shrinkage rate occurred, respectively. The photopolymerization kinetics differed among the measurement methods. The photopolymerization kinetics of composites changed as the radiant emittance and composite type varied. In clinical practice and research on the composite restoration, the kinetics should be considered comprehensively with the complementary use of various measurement methods.
Collapse
Affiliation(s)
- Chang-Ha Lee
- Department of Conservative Dentistry, School of Dentistry and Dental Research Institute, Seoul National University
| | - In-Bog Lee
- Department of Conservative Dentistry, School of Dentistry and Dental Research Institute, Seoul National University
| |
Collapse
|
17
|
Rakić M, Ivanišević A, Baraba A, Agović SČ, Šošić A, Klarić E. Blue Laser for Polymerization of Bulk Fill Composites: Influence on dentin bond strength and temperature rise during curing and co-curing method. Lasers Med Sci 2024; 39:93. [PMID: 38520540 DOI: 10.1007/s10103-024-04040-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Accepted: 03/14/2024] [Indexed: 03/25/2024]
Abstract
Blue diode lasers are alternative curing devices for dental composites. The aim of this study was to investigate the influence of blue diode laser polymerization on shear bond strength of bulk fill composites to human dentin and temperature rise during two types of polymerization. Composite cylinders of SDR Plus(SDR) and Ever X Flow(EX) were bonded to dentin slabs using Adhese Universal and curing devices blue diode laser (449 nm, 1.6 W) and Power Cure LED. For each material and curing device there were two polymerization approaches: 1)conventional: separate curing of adhesive; 2)co-curing: simultaneous adhesive and composite curing. Polymerization modes for each material in conventional and co-curing(c) approach were: blue laser 2000 mW/cm2 for 5 s (L5 and L5c); blue laser 1000 mW/cm2 for 10 s (L10 and L10c); Power Cure 2000 mW/cm2 for 5 s (LED5 and LED5c); Power Cure 1000 mW/cm2 for 10 s (LED10 and LED10c). Temeperature was measured using thermal vision camera. For SDR, the highest bond strength was 24.3 MPa in L10c, and the lowest 9.2 MPa in LED5c. EX exhibited the highest bond strength(21.3 MPa) in LED5, and the lowest in L5(7.7 MPa). The highest temperature rise for SDR was in L10 and L5 (7.3 and 7.2 °C), and the lowest in LED5(0.8 °C). For EX, the highest temperature rise was in L5 (13.0 °C), and the lowest in LED5 (0.7 °C). Temperature rise was higher during blue laser polymerization, especially at high intensity and with conventional curing. Preferable blue laser curing mode is co-curing at 1000mW/cm2 for 10 s.
Collapse
Affiliation(s)
| | - Ana Ivanišević
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Zagreb, Croatia.
| | - Anja Baraba
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Zagreb, Croatia
| | | | - Antonela Šošić
- School of Dental Medicine, University of Zagreb, Zagreb, Croatia
| | - Eva Klarić
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Zagreb, Croatia
| |
Collapse
|
18
|
Elhejazi AA, Alosimi A, Alarifi F, almuqayrin A. The effect of depth of cure on microhardness between bulk-fill and hybrid composite resin material. Saudi Dent J 2024; 36:381-385. [PMID: 38419988 PMCID: PMC10897616 DOI: 10.1016/j.sdentj.2024.01.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Revised: 01/22/2024] [Accepted: 01/24/2024] [Indexed: 03/02/2024] Open
Abstract
Background Functional properties should be considered when selecting composites for restorations. With bulk-fill resin composites, the disadvantages of conventional composites were overcome regarding the increments necessitating the application of a 2 mm thick layer of resin and the amount of polymerization. The most significant advantage of bulk-fill resin composite is the possibility of applying the material in 4 mm layers. Multiple studies have examined the polymerization, mechanical, and adhesive properties of bulk-fill resin composites and proven them successful. Objective This study aimed to compare the effect of the depth of cure on the microhardness between different bulk-fill composites and a hybrid composite material by following the manufacturer's instructions. Methods In this in vitro study, five composite types obtained from different companies were used: two high-viscosity bulk-fill composites, Filtek and OPUS bulk; two low-viscosity bulk-fill flowable composites, Any-com and OPUS flow; one light-cure hybrid composite, Cavex, totaling 25 samples. The composite was applied at a depth of 4 mm in the bulk-fill composite and 2 mm in the hybrid composite and light-cured. The microhardness was measured at three different times. The first time was performed immediately after light-curing, the second time was evaluated 24 h after polymerization, and the third time was after thermocycling. Result A total of 25 samples showed that the microhardness increased the first and second times and decreased the third time after thermocycling on the top and bottom sides of Filtek, OPUS bulk-fill, OPUS flow, and Any-com bulk. The Cavex microhardness at the bottom was equal at all three-time points. Two-way repeated measures ANOVA showed that the microhardness between all types of composite resin materials was significantly different at different times when p = 0.00.
Collapse
Affiliation(s)
- Ahmed A. Elhejazi
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Asim Alosimi
- College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Faisal Alarifi
- College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | | |
Collapse
|
19
|
Profeta Krznar I, Par M, Tarle Z, Meštrović S. Influence of the Bracket Material on the Post-Cure Degree of Conversion of Resin-Based Orthodontic Adhesive Systems. Polymers (Basel) 2024; 16:318. [PMID: 38337207 DOI: 10.3390/polym16030318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Revised: 01/19/2024] [Accepted: 01/23/2024] [Indexed: 02/12/2024] Open
Abstract
The aim of this study was to examine the influence of the orthodontic bracket material on the short-term and long-term post-cure development of the degree of conversion (DC) of resin-based orthodontic adhesive systems. Five commercially available materials characterized by different compositions and curing modes (light-curable or dual-curable) were tested under three different light curing conditions: without brackets (control group, CO), and in the presence of metal brackets (MB group) or ceramic brackets (CB group). Fourier-transform infrared spectroscopy was used to determine the post-cure DC development, both after "short-term" periods (2, 6, and 10 min) and "long-term" periods (1, 7, and 28 days). The short-term DC values ranged from 43.9% to 76.1%, and the long-term DC values were higher and ranged from 54.3% to 85.3%. The MB group demonstrated significantly lower short-term DC values compared to the CO and the CB groups, while the CB group had statistically similar or slightly lower DC values compared to the CO group. Long-term DC values in the MB and the CB groups were statistically lower or similar compared to the CO group, which depended on the post-cure time. The results indicated that the post-cure DC development was highly material-dependent and affected by the presence of different types of bracket material.
Collapse
Affiliation(s)
- Ivona Profeta Krznar
- School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10 000 Zagreb, Croatia
| | - Matej Par
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10 000 Zagreb, Croatia
| | - Zrinka Tarle
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10 000 Zagreb, Croatia
| | - Senka Meštrović
- Department of Orthodontics, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10 000 Zagreb, Croatia
| |
Collapse
|
20
|
Ilie N. The Dependence on Hue, Value and Opacity of Real-Time- and Post-Curing Light Transmission in a Nano-Hybrid Ormocer. MATERIALS (BASEL, SWITZERLAND) 2024; 17:496. [PMID: 38276435 PMCID: PMC10821501 DOI: 10.3390/ma17020496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Revised: 01/11/2024] [Accepted: 01/18/2024] [Indexed: 01/27/2024]
Abstract
This study aims to quantify the influence of hue, value and opacity on the variation in light transmittance of a full color palette of an ormocer-based dental composite. Samples with a thickness of 2 mm were cured in real time while the incident irradiance and light transmittance were recorded with a spectrophotometer, either in real time during the polymerization or through the polymerized composite at different exposure distances. Across the entire shade range, light attenuation was high, varying between 70.3% and 92.1%. The light transmittance during polymerization increased exponentially with exposure time in all shades. The differences between the cured and uncured composites decrease with increasing value and with increasing opacity within a value. The pattern of variation in light transmittance with increasing value is non-linear and depends on the hue, but not on the opacity within a hue. Small variations in value in lighter shades of hue B reduce the transmitted light more than in hue A, while the opposite is true for darker shades. The results strongly suggest an adequate curing of the lower increments in larger restorations, as the additional light expected from curing the upper increments is very small, regardless of hue, value or opacity. An additional unfavorable condition by increasing the exposure distance consistently contributes to a reduction in light transmission and thus further supports the above statement.
Collapse
Affiliation(s)
- Nicoleta Ilie
- Department of Conservative Dentistry and Periodontology, University Hospital, Ludwig-Maximilians-University, Goethestr. 70, D-80336 Munich, Germany
| |
Collapse
|
21
|
Loguercio AD, Ñaupari-Villasante R, Gutierrez MF, Gonzalez MI, Reis A, Heintze SD. 5-year clinical performance of posterior bulk-filled resin composite restorations: A double-blind randomized controlled trial. Dent Mater 2023; 39:1159-1168. [PMID: 37839995 DOI: 10.1016/j.dental.2023.10.018] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 09/07/2023] [Accepted: 10/08/2023] [Indexed: 10/17/2023]
Abstract
OBJECTIVES The aim of this double-blind, and randomized controlled clinical trial was to evaluate the 5-year clinical performance of posterior resin composite restorations placed with the incremental filling technique [IF] or the bulk-fill technique [BF]. Two different adhesive systems were used: etch-&-rinse (ER) or self-etch (SE). METHODS Posterior dental teeth of 72 participants (n = 236), with a cavity depth of at least 3 mm, were randomly divided into four groups. Restorations were applied with either Tetric N-Bond or Tetric N-Bond SE. The composite resin Tetric N-Ceram Bulk-Fill was placed either with IF or BF. Restorations were evaluated using FDI criteria at baseline and after 1, 2, 3, 4, and 5 years. Statistical analysis was performed using the Wilcoxon Signed rank test (a=0.05). RESULTS Two hundred and four restorations were evaluated after 5 years. Eleven restorations were considered 'failed', ten due to fracture (4 IF and 6 BF) and one due to secondary caries (IF). The annual failure rate was 1.2% for BF and 1% for IF (p = 0.35). When comparing BF and IF, no significant differences were found for any of the parameters evaluated (p > 0.05). Regarding the adhesive systems, 44 and 51 restorations showed minor problems in terms of marginal adaptation and staining, with significantly more marginal discoloration when the self-etch adhesive was used (p = 0.002). SIGNIFICANCE The bulk-fill restorative technique showed good clinical behavior compared to the incremental filling technique, especially when using an etch-&-rinse adhesive, after 5 years of clinical evaluation.
Collapse
Affiliation(s)
- Alessandro D Loguercio
- Department of Restorative Dentistry, School of Dentistry, Ponta Grossa State University, Ponta Grossa, PR, Brazil
| | - Romina Ñaupari-Villasante
- Department of Restorative Dentistry, School of Dentistry, Ponta Grossa State University, Ponta Grossa, PR, Brazil
| | - Mario F Gutierrez
- Universidad de los Andes, Chile, Facultad de Odontologia, Chile; University of Chile, Department of Restorative Dentistry, Faculty of Dentistry, Chile
| | | | - Alessandra Reis
- Department of Restorative Dentistry, School of Dentistry, Ponta Grossa State University, Ponta Grossa, PR, Brazil
| | | |
Collapse
|
22
|
Hanzen TA, de Paula AM, Grokoski E, de Oliveira ILM, Arana-Gordillo LA, de Melo Monteiro GQ, Perdigão J, Loguercio AD. Glutaraldehyde-based desensitizer does not influence postoperative sensitivity and clinical performance of posterior restorations: A 24-month randomized clinical trial. Dent Mater 2023; 39:946-956. [PMID: 37648563 DOI: 10.1016/j.dental.2023.08.179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Revised: 08/22/2023] [Accepted: 08/23/2023] [Indexed: 09/01/2023]
Abstract
OBJECTIVES To evaluate the influence of a glutaraldehyde-based desensitizer (GL) on postoperative sensitivity (POS) in posterior bulk-fill resin composite restorations using an adhesive applied in the self-etch (SE) and etch-and-rinse (ER) strategies; and to assess the clinical performance of the restorations. METHODS Posterior resin composite restorations (n = 228) at least 3 mm deep were inserted in 57 subjects using a split-mouth design. The adhesive was applied with/without prior application of a GL. A resin composite was used for all restorations. Spontaneous POS (risk and intensity), as well as POS caused by stimulation with an air blast and assess the response to horizontal and vertical percussion was assessed using two scales in the baseline and after 7, 14, and 30 days. In addition, some parameters were evaluated using FDI criteria up to 24 months of clinical service. RESULTS No significant POS was observed (p > 0.05). A higher absolute risk and intensity of spontaneous POS was observed within 7 days (35.1%), without statistically significant differences among groups. At 24 months 5 restorations were considered clinically unsatisfactory, and 73 restorations showed minor discrepancies in adaptation, with no significant differences between groups (p > 0.05). SIGNIFICANCE A GL agent does not influence POS in posterior restorations with bulk-fill resin composite. It may be considered a dispensable clinical step in the restorative protocol.
Collapse
Affiliation(s)
| | | | - Eduardo Grokoski
- Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Brazil
| | | | | | | | - Jorge Perdigão
- University of Minnesota, Division of Operative Dentistry, Department of Restorative Sciences, Minneapolis, MN, USA.
| | - Alessandro D Loguercio
- Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Brazil
| |
Collapse
|
23
|
Bilgili Can D, Özarslan M. 3D-2D microleakage assessment of preheated bulk-fill composite resin applied with different parameters: a micro-CT analysis. Odontology 2023; 111:942-952. [PMID: 36973535 DOI: 10.1007/s10266-023-00805-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Accepted: 03/14/2023] [Indexed: 03/29/2023]
Abstract
This study evaluated microleakage from class II cavities filled with bulk-fill composite preheated to different temperatures, applied at different thicknesses, and with different polymerization modes. A total of 60 mesio-occlusal cavity were drilled into the extracted human third molars at 2 mm and 4 mm thickness. Preheated bulk-fill composite resin (Viscalor; VOCO, Germany) was applied to the cavities at 68 °C and 37 °C after the adhesive resin was applied, and cured using standard and high-power light-curing modes of a VALO light-curing unit. An incrementally applied microhybrid composite was used as the control. The teeth were subjected to 2000 cycles of heating to 55 °C and cooling to 5 °C with a 30-s hold time. Then, they were immersed in a 50% silver nitrate solution for 24 h and scanned with micro-computed tomography. Scanned data were processed using the CTAn software. Two (2D) and three (3D) dimensional analyses of leached silver nitrate were performed. The data's normality was assessed using the Shapiro-Wilk test before comparisons using a three-way analysis of variance. In both 2D and 3D analysis, bulk-fill composite resin preheated to 68 °C and applied at 2 mm thickness showed less microleakage. In the 3D analysis, restorations applied at 37 °C and 4 mm thickness in high-power mode showed significantly higher values (p < 0.001). Preheated bulk-fill composite resin can be applied at 68 °C and effectively cured at both 2 mm and 4 mm thickness.
Collapse
Affiliation(s)
- Dilber Bilgili Can
- Department of Restorative Dentistry, Faculty of Dentistry, Van Yuzuncu Yil University, Van, 65080, Turkey.
| | - Merve Özarslan
- Department of Prosthetic Dentistry, Faculty of Dentistry, Akdeniz University, Antalya, Turkey
| |
Collapse
|
24
|
Zebic ML, Muric B, Savic-Sevic S, Dzeletovic B, Stratimirovic D, Pantelic D. Real-time multispectral transmission of hard tooth tissues and dental composites with their heating. Dent Mater 2023; 39:903-912. [PMID: 37640636 DOI: 10.1016/j.dental.2023.08.174] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Accepted: 08/16/2023] [Indexed: 08/31/2023]
Abstract
The objective of the study was to investigate the real-time transmission of Violet, Blue, Red and Near Infra-Red (NIR) irradiation through 2 or 4 mm thick dental composites and tooth tissue samples at varying positions of Light Curing Unit (LCU) with polymerization temperature monitoring. METHODS The composites tested were: Filtek Universal Restorative (FUR), Filtek One Bulk Fill (FBF), Tetric EvoCeram (TEC), Tetric Bulk Fill (TBF) and Tetric PowerFill (TPF). The new LCU Pinkwave (a four-wavelength source manufactured by Vista Apex, USA) was placed either centrally or eccentrically for 3 mm above the sample. A Fiber spectrometer detected irradiation and Infrared Thermal camera polymerization temperatures. RESULTS All eccentric LCU positions significantly weaken transmitted spectra for all composites in both thickness, jeopardizing Blue light. The LCU position did not affect transmitted irradiation for tooth tissues. The reduction in wavelength intensity when penetrating through thicker compared to thinner composite samples was 62%, 50% and 31% for Blue, NIR and Red, respectively, and 90%, 50% and 35% for tooth tissue samples, respectively. The temperature of bulk fill composites with additional photoinitiators rises faster. Eccentric LCU positions cause a significant decrease in both speed and the maximal value of temperature rise. Red and NIR irradiations contribute to the polymerization temperature. SIGNIFICANCE Tested LCU source cause considerable inhomogeneity in the emitted and transmitted spectra. Tooth tissues homogenize irradiation, but drastically attenuates it. Red light has better potential than Blue light concerning penetration and could be further investigated as the wavelength for activation of an adjusted photoinitiator.
Collapse
Affiliation(s)
- Maja Lezaja Zebic
- Department of Restorative Odontology and Endodontics, School of Dental Medicine, University of Belgrade, Rankeova 4, Belgrade, Serbia.
| | - Branka Muric
- Institute of Physics, University of Belgrade, Pregrevica 18, 11080 Belgrade, Serbia
| | - Svetlana Savic-Sevic
- Institute of Physics, University of Belgrade, Pregrevica 18, 11080 Belgrade, Serbia
| | - Bojan Dzeletovic
- Department of Restorative Odontology and Endodontics, School of Dental Medicine, University of Belgrade, Rankeova 4, Belgrade, Serbia
| | - Djordje Stratimirovic
- Department of Biophysics, School of Dental Medicine, University of Belgrade, Dr Subotica 1, Belgrade, Serbia
| | - Dejan Pantelic
- Institute of Physics, University of Belgrade, Pregrevica 18, 11080 Belgrade, Serbia
| |
Collapse
|
25
|
Taques LV, Chidoski JC, Ávila BO, Jitumori RT, Gomes JC, Gomes GM. Evaluation of Bond Strength and Fracture Load of Teeth With Flared Root Canals Restored With Prefabricated, Anatomical, and Computer-aided Design and Computer-aided Manufacturing Fiber Posts. Oper Dent 2023; 48:524-537. [PMID: 37635454 DOI: 10.2341/22-083-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/12/2023] [Indexed: 08/29/2023]
Abstract
PURPOSE This study compared the use of anatomical glass fiber posts using bulk-fill composite resin with computer-aided design and computer-aided manufacturing (CAD/CAM) milled glass fiber post in oversized root canals, through bond strength (BS) and fracture resistance (FR) tests (fracture load). METHODS AND MATERIALS A total of 48 mandibular premolars were selected, half of them had their crowns removed at the cemento-enamel junction (CEJ) and the other half were sectioned 2 mm above the CEJ. Subsequently, teeth were endodontically treated. After 1 week, the standard preparation of the canals was carried out, and the roots were divided into three groups (n=16), according to the use of different restorative techniques (control: prefabricated glass fiber post [PFP], direct anatomical glass fiber post [AFP], and CAD/CAM milled glass fiber post [MFP]). After luting procedures using Single Bond Universal and RelyX Ultimate (3M ESPE), for eight teeth in each group, six specimens were obtained (two slices from each root third: cervical, middle, and apical). For the remaining eight roots of each group, standardized preparations for metal-free crowns, milling of 5 mol% yttria-stabilized tetragonal zirconia polycrystalline, cementation of the crowns, and periodontal ligament simulation were performed. Then, for each group, the BS was evaluated through the push-out test, and the FR was evaluated in compression. The data obtained from BS were submitted to two-way analysis of variance (ANOVA; group vs root region) and Tukey (α=0.05) and from FR to one-way ANOVA (group) and Tukey (α=0.05). RESULTS For the BS test, the MFP group was statistically superior to the PFP group in all root regions and was statistically superior to the AFP group only in the cervical region, being statistically similar in the middle and apical root regions. For the FR test, the MFP group was statistically superior to the PFP and AFP groups. CONCLUSION The milled fiber post technique can be a legitimate alternative in the restoration of weakened roots with flared root canals.
Collapse
Affiliation(s)
- L V Taques
- Lucas Vinícius Taques, DDS, MSc, PhD student, Universidade Estadual de Ponta Grossa, Paraná, Brazil
| | - J C Chidoski
- Julio Cezar Chidoski-Filho, DDS, MSc, PhD, Centro Universitário Unifasipe
| | - B O Ávila
- Bianca de Oliveira de Ávila, DDS student, Universidade Estadual de Ponta Grossa, Paraná, Brazil
| | - R T Jitumori
- Renata Terumi Jitumori, DDS, MSc, PhD, Universidade Estadual de Ponta Grossa, Paraná, Brazil
| | - J C Gomes
- João Carlos Gomes, DDS, MSc, PhD, Universidade Estadual de Ponta Grossa, Paraná, Brazil
| | - G M Gomes
- *Giovana Mongruel Gomes, DDS, MSc, PhD, Universidade Estadual de Ponta Grossa, Ponta Grossa, Paraná, Brazil
| |
Collapse
|
26
|
Macan M, Marošević A, Špiljak B, Šimunović L, Par M, Marovic D, Juric-Kacunic D, Tarle Z. Proposition of New Testing Procedure for the Mechanical Properties of Bulk-Fill Materials. MATERIALS (BASEL, SWITZERLAND) 2023; 16:4868. [PMID: 37445183 DOI: 10.3390/ma16134868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 07/05/2023] [Accepted: 07/05/2023] [Indexed: 07/15/2023]
Abstract
This study analysed flexural properties, microhardness, and the degree of conversion (DC) of five bulk-fill composites under clinically relevant conditions (4 mm thick specimens) in comparison to 2 mm specimens according to ISO 4049. Additionally, the effect of rapid polymerisation on 4 mm specimens was evaluated after accelerated aging. DC was measured using Fourier transform infrared spectrometry at 2 and 4 mm thick layers, while flexural properties and Vickers microhardness were tested using 16 × 2 × 2 mm or 16 × 2 × 4 mm specimens. Three polymerisation protocols were used: (I) "ISO": 2 mm thickness, 1000 mW/cm2, double-sided; (II) "10 s": 4 mm thickness, 1000 mW/cm2, one-sided; and (III) "3 s": 4 mm thickness, 2600 mW/cm2, one-sided. Mechanical properties were tested after 1 day, after 10,000 thermocycles, and after 10,000 thermocycles followed by a 7-day immersion in absolute ethanol. The "ISO" protocol produced a higher DC and microhardness of all materials. Elastic modulus was significantly higher for the "ISO" protocol compared to the 4 mm specimens. The differences in flexural strength for all polymerisation protocols were equalised after thermocycling and immersion in absolute ethanol. All tested materials met the ISO 4049 flexural strength requirement (80 MPa) for all polymerisation methods and all aging conditions. Rapid polymerisation achieved nearly optimal properties (ISO), except for elastic modulus, which was significantly reduced in 4 mm samples.
Collapse
Affiliation(s)
- Matea Macan
- Department of Endodontics and Restorative Dental Medicine, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Ana Marošević
- Department of Endodontics and Restorative Dental Medicine, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Bruno Špiljak
- Department of Endodontics and Restorative Dental Medicine, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Luka Šimunović
- Department of Orthodontics, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Matej Par
- Department of Endodontics and Restorative Dental Medicine, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Danijela Marovic
- Department of Endodontics and Restorative Dental Medicine, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | | | - Zrinka Tarle
- Department of Endodontics and Restorative Dental Medicine, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| |
Collapse
|
27
|
Elsahn NA, El-Damanhoury HM, Shirazi Z, Saleh ARM. Surface Properties and Wear Resistance of Injectable and Computer-Aided Design/Computer Aided Manufacturing-Milled Resin Composite Thin Occlusal Veneers. Eur J Dent 2023; 17:663-672. [PMID: 36220115 PMCID: PMC10569885 DOI: 10.1055/s-0042-1750769] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022] Open
Abstract
OBJECTIVES This study was conducted to investigate the microhardness, surface roughness (Ra), and wear behavior of thin occlusal veneers (TOV) fabricated from different injectable composite materials and compare them to a Computer-Aided Design (CAD)/Computer-Aided Manufacturing (CAM) resin-based material. MATERIALS AND METHODS A 1-mm occusal veneer preparation was done in a mandibular right second molar typodont tooth. The prepared model was duplicated to fabricate 32 replicas and divided into four groups (n = 8). Standard TOV were fabricated either indirectly from Cerasmart blocks, Cerasmart, GC (CS), or directly from Beautifil Injectable X, Shofu (BF), G-ænial Universal injectable, GC (GU), or SonicFill 2, Kerr (SF) using the injection molding technique. All the specimens were subjected to both thermomechanical cyclic loading (TMC) in a chewing simulator. Wear measurement was conducted by three-dimensional (3D) scanning of the veneered models before and after TMC, and the difference in the volume of the sample was recorded as the volumetric material loss due to wear. Ra before and after TMC and Vickers microhardness (VHN) of the tested materials were measured using standardized samples (n = 8). Representative samples from each group were investigated under a stereomicroscope and a scanning electron microscope. STATISTICAL ANALYSIS One-way analysis of variance (ANOVA) was applied to detect the effect of material on VHN and wear. Two-way ANOVA was utilized to examine the impact of material and TMC on Ra. Multiple comparisons between the groups were conducted using Tukey's post hoc test (α = 0.05). The Pearson's correlation coefficient was used to determine the relationship between hardness and wear and between roughness and wear (α = 0.05). RESULTS CS exhibited the highest mean VHN (p ≤ 0.001), followed by GU and SF which were statistically similar (p = 0.883) but significantly higher than BF (p < 0.001). After TMC, GU revealed the lowest Ra and volumetric wear (VW), followed by CS, BF, and SF (p < 0.5). A highly significant correlation existed between Ra and VW (p = 0.001, R 2 = 0.9803). CONCLUSION The effect of TMC on the surface properties and wear resistance of the investigated TOV is material-dependent. GU injectable TOV are less influenced by TMC than CS milled TOV. In contrast, BF and SF demonstrated significant VW and Ra which might limit their clinical use as TOV.
Collapse
Affiliation(s)
- Nesrine A. Elsahn
- Department of Clinical Sciences, College of Dentistry, Ajman University, Ajman, United Arab Emirates
- Center of Medical and Bio-allied Health Sciences Research, Ajman University, Ajman, United Arab Emirates
- Department of Operative Dentistry, Faculty of Dentistry, Cairo University, Cairo, Egypt
| | - Hatem M. El-Damanhoury
- Department of Preventive and Restorative Dentistry, College of Dental Medicine, University of Sharjah, Sharjah, United Arab Emirates
| | - Zainab Shirazi
- Center of Medical and Bio-allied Health Sciences Research, Ajman University, Ajman, United Arab Emirates
| | - Abdul Rahman M. Saleh
- Department of Clinical Sciences, College of Dentistry, Ajman University, Ajman, United Arab Emirates
- Center of Medical and Bio-allied Health Sciences Research, Ajman University, Ajman, United Arab Emirates
| |
Collapse
|
28
|
Alharbi R, Alharbi E, Al-Haj Ali SN, Farah RI. Thickness-Dependent Light Transmittance and Temperature Rise in Dual-Cure Bioactive and Light-Cure Bulk-Fill Composite Resins. Polymers (Basel) 2023; 15:2837. [PMID: 37447483 DOI: 10.3390/polym15132837] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 06/24/2023] [Accepted: 06/26/2023] [Indexed: 07/15/2023] Open
Abstract
This study aimed to assess the light transmittance (T) and temperature increase through different increments of dual-cure bioactive bulk-fill restorative material (ACTIVA), light-cure bulk-fill, and conventional composite resin materials. Cylindrical specimens with a diameter of 8 mm and heights of 1, 2, 3, and 4 mm of ACTIVA, Tetric-N-Ceram bulk-fill (TBF), Filtek One bulk-fill (FBF), and Filtek Z250 (FZ) (n = 6 per group, 96 in total) were light-cured with a visible blue low-intensity light-emitting diode (LED) (650-800 mW/cm2 irradiance). T, and the temperature increase, were measured using an optical power meter and a digital thermometer during curing. The T mean values ranged between 0.012 and 0.239 (76.02 to 98.81% light attenuation), while the temperature rise mean values ranged between 9.02 and 20.80 °C. The parameters, including material type (partial eta squared (ηp2) = 0.284, p < 0.0001), thickness (ηp2 = 0.284, p < 0.0001), and their interaction (ηp2 = 0.185, p = 0.047), significantly affected the T values, whereas only the material type (ηp2 = 0.352, p = 0.047) affected the temperature rise values. The T and temperature rise mean values were highest in ACTIVA increments of 1-mm increments, in particular, showing the highest T mean values, followed by similar increments of TBF. A significantly higher T was found in 1-mm increments compared to thicker increments for all materials (p < 0.0001), and a significant positive correlation existed between T and temperature rise values (r = 0.348, p = 0.001). These findings show that the bioactive material ACTIVA and TBF allow for better T than the other materials, with ACTIVA recording a higher temperature rise. However, the large light attenuation observed for all materials, irrespective of thickness, suggests that curing in more than one location with a low-intensity LED is necessary to optimize the curing process. Furthermore, incremental filling of bulk-fill materials using a low intensity LED could be beneficial.
Collapse
Affiliation(s)
- Reema Alharbi
- Dental Intern, College of Dentistry, Qassim University, Al Mulayda 51452, Qassim, Saudi Arabia
| | - Eid Alharbi
- Dental Intern, College of Dentistry, Qassim University, Al Mulayda 51452, Qassim, Saudi Arabia
| | - Sanaa N Al-Haj Ali
- Department of Orthodontics and Pediatric Dentistry, College of Dentistry, Qassim University, Al Mulayda 51452, Qassim, Saudi Arabia
| | - Ra'fat I Farah
- Department of Prosthetic Dental Sciences, College of Dentistry, Qassim University, Al Mulayda 51452, Qassim, Saudi Arabia
| |
Collapse
|
29
|
Burrer P, Par M, Fürer L, Stübi M, Marovic D, Tarle Z, Attin T, Tauböck TT. Effect of polymerization mode on shrinkage kinetics and degree of conversion of dual-curing bulk-fill resin composites. Clin Oral Investig 2023; 27:3169-3180. [PMID: 36869923 PMCID: PMC10264464 DOI: 10.1007/s00784-023-04928-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Accepted: 02/22/2023] [Indexed: 03/05/2023]
Abstract
OBJECTIVES To assess the behavior of dual-cure and conventional bulk-fill composite materials on real-time linear shrinkage, shrinkage stress, and degree of conversion. MATERIALS AND METHODS Two dual-cure bulk-fill materials (Cention, Ivoclar Vivadent (with ion-releasing properties) and Fill-Up!, Coltene) and two conventional bulk-fill composites (Tetric PowerFill, Ivoclar Vivadent; SDR flow + , Dentsply Sirona) were compared to conventional reference materials (Ceram.x Spectra ST (HV), Dentsply Sirona; X-flow; Dentsply Sirona). Light curing was performed for 20 s, or specimens were left to self-cure only. Linear shrinkage, shrinkage stress, and degree of conversion were measured in real time for 4 h (n = 8 per group), and kinetic parameters were determined for shrinkage stress and degree of conversion. Data were statistically analyzed by ANOVA followed by post hoc tests (α = 0.05). Pearson's analysis was used for correlating linear shrinkage and shrinkage force. RESULTS Significantly higher linear shrinkage and shrinkage stress were found for the low-viscosity materials compared to the high-viscosity materials. No significant difference in degree of conversion was revealed between the polymerization modes of the dual-cure bulk-fill composite Fill-Up!, but the time to achieve maximum polymerization rate was significantly longer for the self-cure mode. Significant differences in degree of conversion were however found between the polymerization modes of the ion-releasing bulk-fill material Cention, which also exhibited the significantly slowest polymerization rate of all materials when chemically cured. CONCLUSIONS While some of the parameters tested were found to be consistent across all materials studied, heterogeneity increased for others. CLINICAL RELEVANCE With the introduction of new classes of composite materials, predicting the effects of individual parameters on final clinically relevant properties becomes more difficult.
Collapse
Affiliation(s)
- Phoebe Burrer
- Department of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, 8032, Zurich, Switzerland.
| | - Matej Par
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000, Zagreb, Croatia
| | - Leo Fürer
- Department of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, 8032, Zurich, Switzerland
| | - Michelle Stübi
- Department of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, 8032, Zurich, Switzerland
| | - Danijela Marovic
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000, Zagreb, Croatia
| | - Zrinka Tarle
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000, Zagreb, Croatia
| | - Thomas Attin
- Department of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, 8032, Zurich, Switzerland
| | - Tobias T Tauböck
- Department of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, 8032, Zurich, Switzerland
| |
Collapse
|
30
|
Zhang S, Wang X, Yang J, Chen H, Jiang X. Micromechanical interlocking structure at the filler/resin interface for dental composites: a review. Int J Oral Sci 2023; 15:21. [PMID: 37258568 DOI: 10.1038/s41368-023-00226-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 04/18/2023] [Accepted: 04/19/2023] [Indexed: 06/02/2023] Open
Abstract
Dental resin composites (DRCs) are popular materials for repairing caries or dental defect, requiring excellent properties to cope with the complex oral environment. Filler/resin interface interaction has a significant impact on the physicochemical/biological properties and service life of DRCs. Various chemical and physical modification methods on filler/resin interface have been introduced and studied, and the physical micromechanical interlocking caused by the modification of fillers morphology and structure is a promising method. This paper firstly introduces the composition and development of DRCs, then reviews the chemical and physical modification methods of the filler/resin interface, mainly discusses the interface micromechanical interlocking structures and their enhancement mechanism for DRCs, finally give a summary on the existing problems and development potential.
Collapse
Affiliation(s)
- Shuning Zhang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine; College of Stomatology, Shanghai Jiao Tong University; Shanghai Engineering Research Center of Advanced Dental Technology and Materials; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, Shanghai, China
| | - Xiao Wang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine; College of Stomatology, Shanghai Jiao Tong University; Shanghai Engineering Research Center of Advanced Dental Technology and Materials; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, Shanghai, China
| | - Jiawei Yang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine; College of Stomatology, Shanghai Jiao Tong University; Shanghai Engineering Research Center of Advanced Dental Technology and Materials; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, Shanghai, China
| | - Hongyan Chen
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine; College of Stomatology, Shanghai Jiao Tong University; Shanghai Engineering Research Center of Advanced Dental Technology and Materials; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, Shanghai, China.
| | - Xinquan Jiang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine; College of Stomatology, Shanghai Jiao Tong University; Shanghai Engineering Research Center of Advanced Dental Technology and Materials; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, Shanghai, China.
| |
Collapse
|
31
|
Akiya S, Sato K, Kibe K, Tichy A, Hiraishi N, Prasansuttiporn T, Hosaka K, Foxton RM, Shimada Y, Nakajima M. Polymerization shrinkage of light-cured conventional and bulk-fill composites -The effect of cavity depth and post-curing. Dent Mater J 2023. [PMID: 37032103 DOI: 10.4012/dmj.2022-210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/11/2023]
Abstract
Volumetric shrinkage (VS) of conventional, bulk-fill, and core build-up resin-based composites (RBCs) of various thickness (1-5 mm) was measured using the modified bonded-disk method with confocal laser scanning microscopy. Additionally, the bottom-to-top ratio of Vickers hardness (%VH) was measured. Conventional RBCs exhibited significantly higher VS than bulk-fill and core build-up RBCs (p<0.05). As specimen thickness increased, VS relative to volume (%VS) and difference in VS at each depth (VSdepth) decreased. For conventional RBCs, there was a significant drop in VSdepth between 1 mm and 2 mm (p<0.05), and another drop was observed between 3 mm and 4 mm (p<0.05) where %VH decreased below 90%. For bulk-fill and core build-up RBCs, VSdepth decreased significantly between 2 mm and 3 mm (p<0.05), but %VH exceeded 90% even in 5 mm deep cavities. These results indicated that post-curing contributed to lower shrinkage in deeper layers, and that conventional RBCs were not adequately polymerized at the depth of over 3 mm.
Collapse
Affiliation(s)
- Satoshi Akiya
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Kento Sato
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Kouta Kibe
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Antonin Tichy
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
- Institute of Dental Medicine, First Faculty of Medicine of the Charles University and General University Hospital in Prague
| | - Noriko Hiraishi
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Taweesak Prasansuttiporn
- Department of Restorative Dentistry and Periodontology, Faculty of Dentistry, Chiang Mai University
| | - Keiichi Hosaka
- Department of Regenerative Dental Medicine, Tokushima University
- Institute of Global Affairs, Tokyo Medical and Dental University
| | - Richard M Foxton
- Institute of Global Affairs, Tokyo Medical and Dental University
- Center for Dental Education, Faculty of Dentistry, Oral & Craniofacial Sciences, King's College London
| | - Yasushi Shimada
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Masatoshi Nakajima
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
- Department of Regenerative Dental Medicine, Tokushima University
| |
Collapse
|
32
|
Şenol AA, Karabulut Gençer B, Tarçın B, Kahramanoğlu E, Yılmaz Atalı P. Microleakage and Marginal Integrity of Ormocer/Methacrylate-Based Bulk-Fill Resin Restorations in MOD Cavities: SEM and Stereomicroscopic Evaluation. Polymers (Basel) 2023; 15:polym15071716. [PMID: 37050330 PMCID: PMC10096632 DOI: 10.3390/polym15071716] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 03/23/2023] [Accepted: 03/27/2023] [Indexed: 04/14/2023] Open
Abstract
This in vitro study aimed to compare the microleakage and marginal integrity of methacrylate/ormocer-based bulk-fill composite (BFC) restorations used in cervical marginal relocation with two different layering thicknesses in mesio-occlusal-distal (MOD) cavities exposed to thermo-mechanical loading. Standard MOD cavities were prepared in 60 mandibular molars and assigned into three groups: x-tra fil/AF + x-tra base/XB, Tetric N-Ceram Bulk Fill/TNB + Tetric N-Flow Bulk Fill/TFB, and Admira Fusion x-tra/AFX + Admira Fusion x-base/AFB. Each group was further divided into two subgroups (2 mm and 4 mm) based on the thickness of flowable BFCs (n = 10). The specimens were subjected to thermo-mechanical loading (240,000 cycles) and immersed in 0.2% methylene blue. Following mesiodistal sectioning, the specimens were examined under stereomicroscope (×25) and scored (0-3) for microleakage. Marginal integrity was examined using a scanning electron microscope (SEM). Descriptive statistical methods and the chi-square test were used to evaluate the data (p < 0.05). While there was no statistically significant difference in gingival cement microleakage in the XB and AFB specimens with a 4 mm thickness, microleakage was significantly increased in the TFB specimen (p = 0.604, 0.481, 0.018 respectively). A significantly higher amount of score 0 coronal microleakage was detected in the AFX2 mm + AFB4 mm compared to the TNB2 mm + TFB4 mm (p = 0.039). The SEM examination demonstrated better marginal integrity in groups with 2 mm thick flowable BFCs. Ormocer and methacrylate-based materials can be used in marginal relocation with thin layers.
Collapse
Affiliation(s)
- Aslı A Şenol
- Department of Restorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul 34854, Turkey
| | - Büşra Karabulut Gençer
- Department of Restorative Dentistry, Faculty of Dentistry, Nişantaşı University, Istanbul 34398, Turkey
| | - Bilge Tarçın
- Department of Restorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul 34854, Turkey
| | - Erkut Kahramanoğlu
- Department of Prosthodontic Dentistry, Faculty of Dentistry, Marmara University, Istanbul 34854, Turkey
| | - Pınar Yılmaz Atalı
- Department of Restorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul 34854, Turkey
| |
Collapse
|
33
|
Mosharrafian S, Farahmand N, Poorzandpoush K, Hosseinipour ZS, Kahforushan M. In vitro microleakage at the enamel and dentin margins of class II cavities of primary molars restored with a bulk-fill and a conventional composite. Clin Exp Dent Res 2023. [PMID: 36988512 DOI: 10.1002/cre2.729] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 02/28/2023] [Accepted: 03/12/2023] [Indexed: 03/30/2023] Open
Abstract
OBJECTIVES This study assessed the enamel and dentin margin microleakage of class II cavities of primary molars restored with a bulk-fill and a conventional composite. MATERIALS AND METHODS In this in vitro, experimental study, standard class II cavities were created in the proximal surfaces of 60 extracted primary molars. The teeth were randomly divided into two groups, and restored with SonicFill bulk-fill and Filtek Z250 conventional composite along with Single Bond 2 adhesive. The teeth were coated with two layers of nail varnish to 1 mm around the restoration margins, and the apices were sealed with wax. The teeth underwent 1500 thermal cycles and incubated at 37°C for 24 h. They were then immersed in 1 M silver nitrate in the dark, rinsed with water, immersed in developing solution for 12 h, and exposed to fluorescent light. Next, they were mesiodistally sectioned, and digitally photographed under a stereomicroscope at ×10 magnification. The dye penetration depth was measured by a blind observer, and analyzed by the Mann-Whitney U test (α = .05). RESULTS No significant difference existed in microleakage between the two composite groups at the enamel (p = .76) or dentin (p = .16) margins. In both composite groups, microleakage at the dentin margins was significantly greater than that at the enamel margins (p = .000). CONCLUSION Considering the absence of a significant difference in microleakage, SonicFill bulk-fill composite can be used as an alternative to Filtek Z250 conventional composite for restoration of primary molars to benefit from its advantages such as simpler and faster application.
Collapse
Affiliation(s)
- Shahram Mosharrafian
- Department of Pediatric Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Niloofar Farahmand
- Department of Restorative Dentistry, School of Dentistry, Kashan University of Medical Sciences, Kashan, Iran
| | - Kiana Poorzandpoush
- Department of Pediatric Dentistry, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Zohre Sadat Hosseinipour
- Department of Pediatric Dentistry, School of Dentistry, AJA University of Medical Sciences, Tehran, Iran
| | | |
Collapse
|
34
|
Mechanical and Biomimetic Characteristics of Bulk-Fill Resin Dental Composites Following Exposure in a Simulated Acidic Oral Environment. Biomimetics (Basel) 2023; 8:biomimetics8010019. [PMID: 36648805 PMCID: PMC9844310 DOI: 10.3390/biomimetics8010019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 12/30/2022] [Accepted: 12/31/2022] [Indexed: 01/05/2023] Open
Abstract
During the last 10 years, various companies have marketed different "bulk-fill" resin dental composites for the restoration of posterior stress-bearing teeth; however, the impact of acidic conditions on these relatively newer materials has not been thoroughly investigated. Therefore, an attempt was made to evaluate the effect of acidic beverages on the mechanical biomimetic characteristics of four bulk-fill and one conventional nanohybrid resin-based dental composites (RBCs). The specimens of each RBC were stored in two acidic beverages namely 'Orange Juice' and 'Coca-Cola', whereas 'dry' and 'distilled water' storage of specimens served as controls. After 1 week of storage, flexural and surface hardness properties of specimens were determined using a universal testing machine and Vickers hardness tester, respectively. In general, the 'Coca-Cola' beverage caused the greatest degradation of flexural strength, flexural modulus, and surface hardness characteristics in all RBCs in contrast to the 'dry', 'distilled water' controls and 'Orange Juice' storage conditions. However, the overall mechanical biomimetic performance of nanohybrid RBCs was relatively better than all other bulk-fill RBCs and may, therefore, be considered a suitable candidate for the restoration of posterior stress-bearing permanent dentition.
Collapse
|
35
|
Hirata R, Sampaio CS, Atria PJ, Giannini M, Coelho PG, Yamaguchi S. Effect of High-radiant Emittance and Short Curing Time on Polymerization Shrinkage Vectors of Bulk Fill Composites. Oper Dent 2023; 48:51-58. [PMID: 36534034 DOI: 10.2341/20-167-l] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/18/2022] [Indexed: 12/23/2022]
Abstract
PURPOSE To evaluate the effect of short curing time using a high-radiant emittance light on polymerization shrinkage vectors in different consistency bulk-fill composites (BFRCs) using micro-computed tomography. METHODS AND MATERIALS Radiopaque zirconia fillers were homogeneously incorporated and functioned as radiopaque tracers into two regular-paste: TBFill (Tetric EvoCeram Bulk Fill) and TPFill (Tetric PowerFill), and two flowable (n=6): TBFlow (Tetric EvoFlow Bulk Fill) and TPFlow (Tetric PowerFlow) resin composites. Class I cavities (4 mm depth × 4 mm length × 4 mm width) were 3D-printed and filled in a single increment: TBFill and TBFlow were light-activated using a Bluephase Style 20i (10 seconds in high-mode); TPFill and TPFlow were light-activated using a Bluephase PowerCure (three seconds). The same adhesive system (Adhese Universal) was used for all groups. Microcomputed tomography scans were obtained before and after light-activation. Filler particle movement was identified by polymerization shrinkage vectors at five depths (from 0-4 mm): top, top-middle, middle, middle-bottom and bottom. RESULTS TPFlow showed the lowest total vector displacement, followed by TBFlow, TBFill and TPFill, significantly different among each other (p<0.05). Generally, BFRCs showed decreased vector displacement with increased depth, and higher displacement at the top-surface (p<0.05). Qualitative analysis showed a similar pattern of vector magnitude and displacement for groups TBFill and TPFill, with displacement vectors on occlusal (top) surfaces toward the center of the restoration from the top to middle areas, and relatively limited displacement at the bottom. TBFlow and TPFlow showed more displacement on the occlusal (top). CONCLUSIONS Short curing time with high-radiant emittance on fast-curing BFRCs was shown to be a feasible option in terms of vector displacement. Flowable BFRCs presented lower vector displacement than their regular-viscosity versions.
Collapse
Affiliation(s)
- R Hirata
- Ronaldo Hirata, DDS, MS, PhD, Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY USA
| | - C S Sampaio
- *Camila S Sampaio, DDS, MD, PhD, Department of Biomaterials, School of Dentistry, Universidad de los Andes, Santiago, Chile
| | - P J Atria
- Pablo J Atria, DDS, MS, Department of Biomaterials, School of Dentistry, Universidad de los Andes, Santiago, Chile
| | - M Giannini
- Marcelo Giannini, DDS, MS, PhD, Department of Restorative Dentistry, Operative Dentistry Division, University of Campinas, Piracicaba Dental School, Piracicaba, Brazil
| | - P G Coelho
- Paulo G. Coelho, DDS, MS, PhD, Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY
| | - S Yamaguchi
- Satoshi Yamaguchi, DDS, MS, PhD, Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Osaka, Japan
| |
Collapse
|
36
|
SARIDAĞ S, TEKÇE N, BAŞPINAR ALPER S, DERELİ İNAN B. Bond Strength of Different Composite Resin Materials and CAD/CAM Restorative Materials to Each Other and Dentin Tissue. BEZMIALEM SCIENCE 2022. [DOI: 10.14235/bas.galenos.2022.54154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
37
|
Kim YS, Baek SH, Kim RJY. Effect of vibration during bulk and incremental filling on adaptation of a bulk-fill composite resin. Sci Rep 2022; 12:21652. [PMID: 36522452 PMCID: PMC9755266 DOI: 10.1038/s41598-022-26197-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Accepted: 12/12/2022] [Indexed: 12/23/2022] Open
Abstract
This study evaluated the effect of vibration on adaptation of bulk-fill composite resin. A scanning laser doppler vibrometer measured the frequency and amplitude of a vibratory device (COMO; B&L Biotech) used for resin placement and visualized its effect on the resin according to depth. A bulk-fill composite resin (Filtek Bulk Fill; 3M ESPE) was placed in simulated cavities (4 mm diameter, 4 mm depth) by different layering methods (incremental filling with two 2-mm-thick layers vs. bulk filling with a single 4-mm-thick layer). The groups were further divided based on the application of vibration during restoration (no vibration vs. vibration). In addition to the surface void area at the cavity floor, the overall void volume and the void volumes of the bottom, middle, and top thirds were obtained for micro-computed tomography analysis. The frequency and amplitude of the COMO were approximately 149 Hz and between 26 and 51 µm, respectively. When vibration was not applied, incremental filling had a lower void volume in the bottom third of the cavity than did bulk filling (p < 0.05). Vibration applied with a 4-mm-thick bulk fill had no significant effect on the adaptation of composite resin (p > 0.05). In contrast, vibration reduced the amount of void formation in the bottom third of the cavity during incremental filling (p < 0.05). Application of vibration to resin with a 2-mm incremental-layering technique formed a smaller void at the interface between the cavity and resin and within the bulk-fill composite resin.
Collapse
Affiliation(s)
- Yung-Soo Kim
- grid.31501.360000 0004 0470 5905School of Dentistry, Seoul National University, 101 Daehak-ro, Jongno-gu, Seoul, Republic of Korea
| | - Seung-Ho Baek
- grid.31501.360000 0004 0470 5905Department of Conservative Dentistry, Dental Research Institute, School of Dentistry, Seoul National University, 101 Daehak-ro, Jongno-gu, Seoul, Republic of Korea
| | - Ryan Jin Young Kim
- grid.31501.360000 0004 0470 5905Dental Research Institute, School of Dentistry, Seoul National University, 101 Daehak-ro, Jongno-gu, Seoul, Republic of Korea
| |
Collapse
|
38
|
Yılmaz Atalı P, Doğu Kaya B, Manav Özen A, Tarçın B, Şenol AA, Tüter Bayraktar E, Korkut B, Bilgin Göçmen G, Tağtekin D, Türkmen C. Assessment of Micro-Hardness, Degree of Conversion, and Flexural Strength for Single-Shade Universal Resin Composites. Polymers (Basel) 2022; 14:polym14224987. [PMID: 36433113 PMCID: PMC9697557 DOI: 10.3390/polym14224987] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 11/12/2022] [Accepted: 11/14/2022] [Indexed: 11/19/2022] Open
Abstract
Single-shade universal resin composites (SsURC) are preferred in clinical practice to reduce time for shade selection and obtain good esthetic results. In this study, the static mechanical properties of seven new SsURCs were investigated, their spectral analyzes were performed and scanning electron microscopy (SEM) evaluations were presented. Charisma Diamond One/DO, Admira Fusion x-tra/AFX, Omnichroma/OC, OptiShade/OS, Essentia Universal/EU, Zenchroma/ZC, Vittra APS Unique/VU were used in a three-point bending test to determine flexural strength (FS) and elastic modulus (EM); Vickers micro-hardness (VHN) and hardness-ratio (HR) were performed with a micro-hardness tester from top/bottom after 24-h/15-days of storage in distilled water at 37 °C (±1 °C). The degree of conversion (DC) was assessed by using Fourier transform infrared spectroscopy (FTIR). The structure of the resin matrix and filler content were assessed by SEM. Data were analyzed using IBM SPSS V23 and the R program and the significance level was taken as p < 0.05. The main effect of the tested SsURCs was found to be statistically significant on FS, EM, VHN, and DC values (p < 0.001). Bis-GMA free SsURCs (AFX, DO, VU) showed better DC and HR except for OC. All seven tested SsURCs conform to the requirements of ISO standards for dental resin composites for all tested categories.
Collapse
|
39
|
Ilie N. Resin-Based Bulk-Fill Composites: Tried and Tested, New Trends, and Evaluation Compared to Human Dentin. MATERIALS (BASEL, SWITZERLAND) 2022; 15:8095. [PMID: 36431581 PMCID: PMC9694352 DOI: 10.3390/ma15228095] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Revised: 11/10/2022] [Accepted: 11/14/2022] [Indexed: 06/16/2023]
Abstract
A more-and-more-accepted alternative to the time-consuming and technique-sensitive, classic, incremental-layering technique of resin-based composites (RBCs) is their placement in large increments. The so-called bulk-fill RBCs had to be modified for a higher polymerization depth and already have a 20-year history behind them. From the initial simple mechanisms of increasing the depth of cure by increasing their translucency, bulk-fill RBCs have evolved into complex materials with novel polymerization mechanisms and bioactive properties. However, since the materials are intended to replace the tooth structure, they must be comparable in mechanical behavior to the substance they replace. The study compares already established bulk-fill RBCs with newer, less-studied materials and establishes their relationship to dentin with regard to basic material properties such as hardness and indentation modulus. Instrumented indentation testing enables a direct comparison of tooth and material substrates and provides clinically relevant information. The results underline the strong dependence of the measured properties on the amount of filler in contrast to the small influence of the material classes into which they are classified. The main difference of RBCs compared to dentin is a comparable hardness but a much lower indentation modulus, emphasizing further development potential.
Collapse
Affiliation(s)
- Nicoleta Ilie
- Department of Conservative Dentistry and Periodontology, University Hospital, Ludwig Maximilian University of Munich, Goethestr. 70, 80336 Munich, Germany
| |
Collapse
|
40
|
Niem T, Frankenberger R, Amend S, Wöstmann B, Krämer N. Damping Behaviour and Mechanical Properties of Restorative Materials for Primary Teeth. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7698. [PMID: 36363290 PMCID: PMC9656603 DOI: 10.3390/ma15217698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/14/2022] [Revised: 09/30/2022] [Accepted: 10/19/2022] [Indexed: 06/16/2023]
Abstract
The energy dissipation capacity and damping ability of restorative materials used to restore deciduous teeth were assessed compared to common mechanical properties. Mechanical properties (flexural strength, modulus of elasticity, modulus of toughness) for Compoglass F, Dyract eXtra, SDR flow, Tetric Evo Ceram, Tetric Evo Ceram Bulk Fill, and Venus Diamond were determined using a 4-point bending test. Vickers hardness and Martens hardness, together with its plastic index (ηITdis), were recorded using instrumented indentation testing. Leeb hardness (HLD) and its deduced energy dissipation data (HLDdis) were likewise determined. The reliability of materials was assessed using Weibull analysis. For common mechanical properties, Venus Diamond always exhibited the significantly highest results and SDR flow the lowest, except for flexural strength. Independently determined damping parameters (modulus of toughness, HLDdis, ηITdis) invariably disclosed the highest values for SDR flow. Composite materials, including SDR flow, showed markedly higher reliabilities (Weibull modulus) than Compoglass F and Dyract eXtra. SDR flow showed pronounced energy dissipation and damping characteristics, making it the most promising material for a biomimetic restoration of viscoelastic dentin structures in deciduous teeth. Future developments in composite technology should implement improved resin structures that facilitate damping effects in artificial restorative materials.
Collapse
Affiliation(s)
- Thomas Niem
- Department of Prosthodontics, Medical Center for Dentistry, Justus Liebig University Giessen and University Hospital Giessen and Marburg, Campus Giessen, Schlangenzahl 14, 35392 Giessen, Germany
| | - Roland Frankenberger
- Department of Operative Dentistry, Endodontics and Pediatric Dentistry, Medical Center for Dentistry, University of Marburg and University Hospital Giessen and Marburg, Campus Marburg, Georg Voigt Strasse 3, 35039 Marburg, Germany
| | - Stefanie Amend
- Department of Paediatric Dentistry, Medical Centre for Dentistry, Justus Liebig University Giessen and University Hospital Giessen and Marburg, Campus Giessen, Schlangenzahl 14, 35392 Giessen, Germany
| | - Bernd Wöstmann
- Department of Prosthodontics, Medical Center for Dentistry, Justus Liebig University Giessen and University Hospital Giessen and Marburg, Campus Giessen, Schlangenzahl 14, 35392 Giessen, Germany
| | - Norbert Krämer
- Department of Paediatric Dentistry, Medical Centre for Dentistry, Justus Liebig University Giessen and University Hospital Giessen and Marburg, Campus Giessen, Schlangenzahl 14, 35392 Giessen, Germany
| |
Collapse
|
41
|
Gindri LD, Cassol IP, Fröhlich TT, Rocha RDO. One-year clinical evaluation of class II bulk-fill restorations in primary molars: a randomized clinical trial. Braz Dent J 2022; 33:110-120. [PMID: 36477958 PMCID: PMC9733372 DOI: 10.1590/0103-6440202205069] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Accepted: 10/13/2022] [Indexed: 12/12/2022] Open
Abstract
This double-blind, randomized clinical trial aimed to compare the clinical performance and clinical time to restore occluso-proximal cavities in primary molars withbulk-fillresin and conventional resin. A total of 140 class II restorations in primary molars of 65 participants (mean age of 6.7 + 1.5) were placed in two random groups:bulk-filland conventional resin. The restorations were evaluated using FDI criteria at the baseline, 6-month, and one year by a single calibrated examiner, and the clinical restorative time was measured with a digital timer. The success and survival of the restorations were evaluated with Kaplan-Meier graphs. The log-rank test compared the curves. Differences in restorative clinical time were compared using the Mann-Whitney U test. The level of significance was 5%. After one year, 115 restorations were evaluated. The success probability was 88.7% for Filtek Z350 XT and 85.9% for FiltekTM Bulk-fill, and for the survival probability, Filtek Z350 XT presented 90%, and FiltekTM Bulk-fill presented 93.7%. No significant difference was found between the success and survival curves (p=0.62), (p=0.51). The main reason for failure was marginal adaptation.Bulk-fillresin required 30% less time than the conventional resin (p<0.001).Bulk-fillresin presented similar clinical performance to the conventional resin and required less restorative clinical time. It is an option to restore class II lesions of primary molars.
Collapse
|
42
|
Francis N, Rajan RR, Kumar V, Varughese A, Karuveetil V, Sapna CM. Effect of irradiance from curing units on the microhardness of composite - a systematic review. Evid Based Dent 2022:10.1038/s41432-022-0824-z. [PMID: 36253517 DOI: 10.1038/s41432-022-0824-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Accepted: 02/07/2022] [Indexed: 11/08/2022]
Abstract
Purpose The systematic review aims to evaluate the effect of light irradiance from light-curing units on microhardness of composite.Materials and methods The protocol was registered in PROSPERO following which primary search was carried out via MedLine, Scopus and Cochrane Library. A customised tool was used to assess the risk of bias. Among the 303 records retrieved from the databases, only ten articles qualified for qualitative synthesis after meeting all the requirements of the eligibility criteria. Covidence software was used to record the decisions. The studies published until 31 March 2021 were taken up for the review. The articles showed a low-to-moderate risk of bias.Results From a total of 303 articles, ten articles were reviewed for full text. Ten in vitro studies were included for qualitative analysis. There was heterogeneity in sample size, curing time and outcome measured. Therefore, meta-analysis was not performed. Out of ten studies, seven studies reported higher microhardness value for higher intensity than lower intensity of light.Conclusion Despite the fact that the findings of the evaluated studies are quite variable, significant scientific evidence revealed that high light intensity can enhance the hardness of resin composites.
Collapse
Affiliation(s)
- Neenu Francis
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi 682041, India.
| | - Rakesh R Rajan
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi 682041, India
| | - Vijay Kumar
- Department of Public Health Dentistry, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi 682041, India
| | - Anju Varughese
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi 682041, India
| | - Vineetha Karuveetil
- Department of Public Health Dentistry, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi 682041, India
| | - C M Sapna
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi 682041, India
| |
Collapse
|
43
|
Daabash R, Alshabib A, Alqahtani MQ, Price RB, Silikas N, Alshaafi MM. Ion releasing direct restorative materials: Key mechanical properties and wear. Dent Mater 2022; 38:1866-1877. [DOI: 10.1016/j.dental.2022.09.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 09/18/2022] [Accepted: 09/22/2022] [Indexed: 11/15/2022]
|
44
|
Dual-cure dental composites: can light curing interfere with conversion? J Mech Behav Biomed Mater 2022; 132:105289. [DOI: 10.1016/j.jmbbm.2022.105289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 05/17/2022] [Accepted: 05/19/2022] [Indexed: 11/21/2022]
|
45
|
Investigation of the Effects of Adhesive Materials of Different Types and Thicknesses on Dental Tissue Stress via FEM Analysis. BIOMED RESEARCH INTERNATIONAL 2022; 2022:8493909. [PMID: 35915790 PMCID: PMC9338850 DOI: 10.1155/2022/8493909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 05/31/2022] [Accepted: 07/04/2022] [Indexed: 11/17/2022]
Abstract
The aim of this study was to investigate the types and thicknesses of adhesive materials used in restorative treatment in dentistry in class I occlusal and class II disto-occlusal cavities and to examine the effects of stress distribution on enamel, dentin, restoration material, and adhesive material using the finite element stress analysis method. A 3-dimensional geometry of the tooth was obtained by scanning the extracted 26 numbered upper molar tooth with dental tomography. The 3D geometry obtained by using the Geomagic Design X 2020.0 software was divided into surfaces, and necessary arrangements were made. With the Solidworks 2013 software, 2 different cavity modeling, class I occlusal and class II disto-occlusal, with a cavity angle of 95 degrees on the 3D model, as well as 10, 30, and 50 micrometers thick, four types of adhesive materials and the modeling of the bulk-fill composite material on it were made. With finite element stress analysis, the stress distribution was analyzed using the Abaqus software. The materials used in the study are included in the simulation as isotropic linear elastic. Periodontal ligament and jawbone were not included in the analysis. A total of 600 N pressure was applied on the models. In our study, it was observed that the amount of stress on the tooth structures changed when the thickness, elastic modulus, and Poisson ratios of the adhesive material were changed. In addition, when all models are examined, it is seen that when the thickness is increased, more stress is placed on the adhesive material compared to the restoration, while when 50-micrometer-thick adhesive material is used, more stress is placed on the restoration compared to the adhesive material.
Collapse
|
46
|
Oh HJ, Lee CH, Lee IB. Real-time measurement of transmittance changes during photo-polymerization of conventional and bulk-fill composites. Dent Mater J 2022; 41:800-807. [PMID: 35858790 DOI: 10.4012/dmj.2022-009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study investigated transmittance changes during photo-polymerization of composites in real-time. The transmittance changes of one conventional micro-hybrid, three conventional nano-hybrid, and four bulk-fill composites were measured before, during, and after photo-polymerization, and the maximum rate of transmittance change was compared with that of polymerization shrinkage. A significant difference in transmittance of composite between before and after photo-polymerization was observed. The transmittance of composites except for one bulk-fill composite increased during photo-polymerization. There was a correlation between the maximum rate of transmittance change and the maximum rate of polymerization shrinkage. The transmittance analysis of composites gives very important information to know for the final aesthetic restoration and allows to evaluate polymerization kinetics.
Collapse
Affiliation(s)
- Hyun-Jin Oh
- Department of Conservative Dentistry and Dental Research Institute, School of Dentistry, Seoul National University
| | - Chang-Ha Lee
- Department of Conservative Dentistry and Dental Research Institute, School of Dentistry, Seoul National University
| | - In-Bog Lee
- Department of Conservative Dentistry and Dental Research Institute, School of Dentistry, Seoul National University
| |
Collapse
|
47
|
Al Nahedh H, Al-Senan DF, Alayad AS. The Effect of Different Light-curing Units and Tip Distances on the Polymerization Efficiency of Bulk-fill Materials. Oper Dent 2022; 47:E197-E210. [PMID: 36001811 DOI: 10.2341/20-282-l] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/29/2021] [Indexed: 11/23/2022]
Abstract
PROBLEM STATEMENT In an average class II posterior preparation, the curing light tip is placed at a distance from the restoration surface that far exceeds the 1-mm manufacturer's recommendation. This distance can have potentially detrimental effects on the curing efficiency of the light-curing unit as well as the properties of the resin-based composite restoration, especially at the bottom of the cavity preparation. PURPOSE The purpose of this study was to evaluate the effects of various types of light-curing units (LCUs) and the different curing distances on the degree of conversion (DC) and the surface hardness of bulk-fill composite materials. METHODS AND MATERIALS A total of 390 specimens of three resin-based composites (RBCs) were fabricated. Two bulk-fill RBCs, including Filtek Bulk Fill Posterior (3M ESPE GmbH, Seefeld, Germany) and Tetric N-Ceram Bulk Fill (Ivoclar Vivadent AG, Schaan, Liechtenstein), as well as a Filtek Z350 XT nano-filled composite (3M ESPE GmbH, Seefeld, Germany), were utilized. In this study, the Vickers microhardness number (VMN) and the DC were evaluated at 2 and 4 mm thicknesses. Polymerization for 20 seconds was performed using two high-power light-curing units, namely the polywave Bluephase G2 light-emitting diode (LED) LCU (Ivoclar Vivadent AG, Schaan, Liechtenstein) and the monowave Elipar Deep Cure S LED LCU (3M Oral Care, St Paul, MN, USA) at 0, 2, and 4 mm distance between the curing tip and the RBC surface. The results were analyzed using the two-way analysis of variance method. Scheffe's post-hoc multiple comparison tests were used to determine significant differences between the materials, the LCU, and the tip distances. RESULTS The highest DC (70.17) was shown by Filtek Bulk Fill Posterior at a distance of 0 mm, whereas the lowest DC (45.99) was measured for the conventional Filtek Z350 XT at a 4 mm distance. Moreover, higher VMNs were shown by Filtek Bulk Fill and Filtek Z350 composites at 0 mm distance than by the Tetric N-Ceram Bulk Fill composite material when cured with a Bluephase G2 LCU. For all materials, a significant decrease in the DC and mean VMN values was observed at a 4 mm distance in comparison with 0 and 2 mm distances. CONCLUSIONS The DC and VMN values among the studied bulk fill materials were more significantly affected by the material composition and curing protocols. The increased distance from the light tip has a detrimental effect on the mechanical properties of composite resin materials. Significant differences were observed in the curing efficiency of the two LCUs investigated.
Collapse
Affiliation(s)
- Hna Al Nahedh
- *Hend N A Al Nahedh, BDS, MSD, College of Dentistry, Department of Restorative Dental Sciences, King Saud University, Riyadh, Saudi Arabia
| | - D F Al-Senan
- Dana F Al-Senan, BDS, MSD, College of Dentistry, Clinical Dental Sciences Department, Princess Nourah University, Riyadh, Saudi Arabia
| | - A S Alayad
- Abdullah S Alayad, BDS, CAGS, MSD, DScD, College of Dentistry, Department of Restorative Dental Sciences, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
48
|
Ludovichetti FS, Lucchi P, Zambon G, Pezzato L, Bertolini R, Zerman N, Stellini E, Mazzoleni S. Depth of Cure, Hardness, Roughness and Filler Dimension of Bulk-Fill Flowable, Conventional Flowable and High-Strength Universal Injectable Composites: An In Vitro Study. NANOMATERIALS 2022; 12:nano12121951. [PMID: 35745293 PMCID: PMC9228197 DOI: 10.3390/nano12121951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2022] [Revised: 05/27/2022] [Accepted: 06/01/2022] [Indexed: 01/27/2023]
Abstract
(1) Objective: To evaluate and compare the depth of cure (DOC) of two bulk-fill flowable composites (Filtek Bulk Fill Flowable Restorative and Tetric EvoFlow Bulk Fill), two conventional flowable composites (Filtek Supreme XTE Flowable Restorative and G-ænial Flo X) and one high-strength universal injectable composite (G-ænial Universal Injectable). (2) Methods: specimens were placed in a stainless-steel mold with an orifice of 4 mm in diameter and 10 mm in depth and light-cured for 20 s using a light emitting diode (LED) light-curing unit (LCU) with an irradiance of 1000 mW/cm2; depth of cure was assessed using the ISO 4049 scrape technique, and the absolute length of the specimen of cured composite was measured in millimeters with a digital caliper. The same procedure was repeated with 14 samples for each material under investigation, for a total number of 70 test bodies. Material roughness and hardness results were also investigated using, respectively, a 3D laser confocal microscope (LEXT OLS 4100; Olympus) at ×5 magnification and a Vickers diamond indenter (Vickers microhardness tester, Shimadzu®, Kyoto, Japan) under 10-N load and a 30 s dwell time. SEM images at 3000 and 9000 magnification were collected in order to study the materials’ filler content. Statistical analysis were performed by a commercial statistical software package (SPSS) and data were analyzed using multiple comparison Dunnett’s test. (3) Results: The average DOC of both bulk-fill composites was more than 4 mm, as a range of 3.91 and 4.53 mm with an average value of 4.24 and 4.12 mm, while that of the conventional flowable composites was much lower, as a range of 2.47 and 2.90 mm with an average value of 2.58 and 2.84 mm; DOC of the high-strength injectable composite was greater than the one of traditional composites, but not to the level of bulk-fill materials, as a range of 2.82 and 3.01 mm with an average value of 3.02 mm. Statistical analysis revealed significant differences (p-values < 0.05) in the depth of cure between bulk fill flowable composites and other composites, while there was no difference (p-values > 0.05) between the materials of the same type. (4) Conclusions: Bulk-fill flowable composites showed significantly higher depth of cure values than both traditional flowable composites and high-strength injectable composites.
Collapse
Affiliation(s)
- Francesco Saverio Ludovichetti
- Department of Neurosciences–Dentistry Section, Università degli Studi di Padova, 35121 Padova, Italy; (P.L.); (G.Z.); (E.S.); (S.M.)
- Correspondence: ; Tel.: +39-0498212040
| | - Patrizia Lucchi
- Department of Neurosciences–Dentistry Section, Università degli Studi di Padova, 35121 Padova, Italy; (P.L.); (G.Z.); (E.S.); (S.M.)
| | - Giulia Zambon
- Department of Neurosciences–Dentistry Section, Università degli Studi di Padova, 35121 Padova, Italy; (P.L.); (G.Z.); (E.S.); (S.M.)
| | - Luca Pezzato
- Department of Industrial Engineering, Università degli Studi di Padova, 35121 Padova, Italy; (L.P.); (R.B.)
| | - Rachele Bertolini
- Department of Industrial Engineering, Università degli Studi di Padova, 35121 Padova, Italy; (L.P.); (R.B.)
| | - Nicoletta Zerman
- Department of Pediatric Dentisrty, Università degli Studi di Verona, 37129 Verona, Italy;
| | - Edoardo Stellini
- Department of Neurosciences–Dentistry Section, Università degli Studi di Padova, 35121 Padova, Italy; (P.L.); (G.Z.); (E.S.); (S.M.)
| | - Sergio Mazzoleni
- Department of Neurosciences–Dentistry Section, Università degli Studi di Padova, 35121 Padova, Italy; (P.L.); (G.Z.); (E.S.); (S.M.)
| |
Collapse
|
49
|
Bayrak GD, Yaman-Dosdogru E, Selvi-Kuvvetli S. The Effect of Two Different Light-Curing Units and Curing Times on Bulk-Fill Restorative Materials. Polymers (Basel) 2022; 14:1885. [PMID: 35567054 PMCID: PMC9104037 DOI: 10.3390/polym14091885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 05/02/2022] [Accepted: 05/03/2022] [Indexed: 12/05/2022] Open
Abstract
This study aimed to evaluate the effect of two different light-curing units and curing times on the surface microhardness (SMH), compressive strength (CS), and volumetric shrinkage (VS) of four restorative materials (FiltekTM Z250, FiltekTM Bulk Fill Posterior, Beautifil® Bulk Restorative, ACTIVATM BioACTIVE). For all tests, each material was divided into two groups depending on the curing unit (Woodpecker LED-E and CarboLED), and each curing unit group was further divided into two subgroups according to curing time (10 s and 20 s). SMH was evaluated using a Vickers hardness tester, CS was tested using a universal testing machine, and VS was measured using video imaging. In all the restorative materials cured with Woodpecker LED-E, the 20 s subgroup demonstrated significantly higher SMH values than the 10 s subgroup. In both light-curing time subgroups, the CarboLED group showed significantly higher CS values than the Woodpecker LED-E group for all restorative materials except FiltekTM Bulk Fill Posterior cured for 20 s. ACTIVATM BioACTIVE showed significantly greater volumetric change than the other restorative materials. A higher curing light intensity and longer curing time had a positive effect on the SMH and CS of the restorative materials tested in this study. On the other hand, curing unit and time did not show a significant effect on the VS values of restorative materials.
Collapse
Affiliation(s)
- Gokcen Deniz Bayrak
- Department of Pediatric Dentistry, Faculty of Dentistry, University of Yeditepe, Bagdat Cd. No. 238, Istanbul 34728, Turkey; (E.Y.-D.); (S.S.-K.)
| | | | | |
Collapse
|
50
|
Hahn B, Haubitz I, Krug R, Krastl G, Soliman S. Influence of Matrix Type on Marginal Gap Formation of Deep Class II Bulk-Fill Composite Restorations. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:4961. [PMID: 35564356 PMCID: PMC9099621 DOI: 10.3390/ijerph19094961] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 04/12/2022] [Accepted: 04/15/2022] [Indexed: 02/01/2023]
Abstract
Background: To test the hypothesis that transparent matrices result in more continuous margins of bulk-fill composite (BFC) restorations than metal matrices. Methods: Forty standardized MOD cavities in human molars with cervical margins in enamel and dentin were created and randomly assigned to four restorative treatment protocols: conventional nanohybrid composite (NANO) restoration (Tetric EvoCeram, Ivoclar Vivadent, Schaan, Liechtenstein) with a metal matrix (NANO-METAL) versus transparent matrix (NANO-TRANS), and bulk-fill composite restoration (Tetric EvoCeram Bulk Fill, Ivoclar Vivadent, Schaan, Liechtenstein) with a metal matrix (BFC-METAL) versus transparent matrix (BFC-TRANS). After artificial aging (2500 thermal cycles), marginal quality was evaluated by scanning electron microscopy using the replica technique. Statistical analyses were performed using the Mann−Whitney U-test and Wilcoxon test. The level of significance was p < 0.05. Results: Metal matrices yielded significantly (p = 0.0011) more continuous margins (46.211%) than transparent matrices (27.073%). Differences in continuous margins between NANO (34.482%) and BFC (38.802%) were not significant (p = 0.56). Matrix type did not influence marginal gap formation in BFC (p = 0.27) but did in NANO restorations (p = 0.001). Conclusion: Metal matrices positively influence the marginal quality of class II composite restorations, especially in deep cavity areas. The bulk-fill composite seems to be less sensitive to the influence of factors such as light polymerization and matrix type.
Collapse
Affiliation(s)
- Britta Hahn
- Department of Conservative Dentistry and Periodontology, University Hospital Würzburg, Pleicherwall 2, 97070 Würzburg, Germany; (I.H.); (R.K.); (G.K.); (S.S.)
| | | | | | | | | |
Collapse
|